HomeMy WebLinkAbout26 Civic Center Plz - REV 5 - PlanNOTE: INSULATE HOT WATER & DRAIN PIPE. THERE SHALL BE NO SHARP OR ABRASIVE OBJECTS UNDER THE LAVATORY LAVATORY AND MIRROR ACCESSIBLE URINAL MIRROR 0' - 9 " M I N . 40 " M A X . KNEE CLR 8" MIN. 25" MAX. 17" MIN. 27 " M I N . 29 " M I N . 34 " M A X . 18" MIN. 17 " M A X . 44 " M A X . 13 1/2" MIN. FLUSH CONTROL OR AUTOMATIC FLUSH VALVE 24" MIN.12" MIN. 36" MIN. 17" TO 18" PARTITION OR FIXTURE 60" MIN. TO ACCESSIBLE TOILET 1-1/2"1-1/2" GRAB BAR 17 " T O 1 9 " F O R AC C T . O . S E A T FL U S H C O N T R O L 44 " M A X . T O 12" MAX.42" MIN. 7"-9" 54" MIN. 24" MIN. 48" CLEAR AT ACCESSIBLE TOILET WITH FRONT DOOR 60" CLEAR AT ACCESSIBLE TOILET COMPARTMENT WITH SIDE DOOR TO O U T L E T 19 " M I N . TO 3 6 " M A X . 33 " M I N . TOILET PAPER HOLDER GRAB BAR 1' - 0 " 4' - 6 " PER PLANS 15 " M I N . 48 " M A X . ACCESSIBLE TOILET URINAL SCREEN ELECTRICAL SWITCHES & OUTLETS PUSH BUTTON DOOR OPERATOR 44 " A . F . F . 30 " T O 40 " M A X . 3' - 6 " 6' - 8 " OR 6 " M I N . B E L O W CE I L I N G W H I C H E V E R IS L O W E R AC C . M A X . 4' - 0 " 5' - 0 " AC C . M A X . 4' - 0 " 5' - 0 " (4 8 " M A X . ) 40 " T O HA N D L E C E N T E R WIDTH PER ELEVATIONS 4' - 2 " T Y P . W H E N O P E N 34 " M A X . T O T O P O F WO R K S U R F A C E B. O . RE F L E C T .SU R F A C E BABY CHANGER (HORIZONTAL) SANITAR Y NAPKIN/ TAMPON VENDOR PAPER TOWEL DISPENSER AND WASTE RECEPTACLE TOILET SEAT COVER AND TOILET TISSUE DISPENSER W/ SANITARY NAPKIN DISPOSAL AT WOMEN'S TOILET HAND DRYER SOAP DISPENSER 0' - 4" MAX. SIDE FRONT 40" MAX. (36" MAX. FOR CHILDREN) A.F.F. TO OPERABLE PARTS (INCLUDING COINSLOTS) OF ALL ACCESSORIES CARD READER FIRE ALARM (STROBE AND ALARM/STROBE) PULL STATION HAT AND COAT HOOK MOP HOLDER FIRE EXTINGUISHER CABINET MIRROR NOTE: 48" MAX. HEIGHT WITH UP TO 20" MAX HORIZONTAL OBSTRUCTION FOR FORWARD REACH OR UP TO 10" MAX. HORIZONTAL OBSTRUCTION FOR SIDE REACH 44" MAX. HEIGHT FORWARD REACH WITH >20" TO 25" MAX. HORIZONTAL OBSTRUCTION. 46" MAX. SIDE REACH WITH >10" TO 24" MAX. HORIZONTAL OBSTRUCTION HORIZONTAL OBSTRUCTION UP TO 34" MAX. HEIGHTCBC 2022 11B-603.5 ACCESSORIES ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40" MAX AFF. EXCEPTION: BABY DIAPER CHANGING STATIONS. NOTES: 1. FLUSH CONTROLS FOR THE WATER CLOSETS SHALL BE AUTOMATIC OR OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWIST OF THE WRIST. CONTROLS FOR THE FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN 44" A.F.F. THE FORCE TO ACTIVATE THE CONTROLS SHALL BE NO GREATER THAN 5 LB. 2. FLUSH CONTROLS FOR THE URINALS SHALL BE AUTOMATIC OR OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWIST OF THE WRIST AND SHALL BE MOUNTED NO MORE THAN 44" A.F.F. THE FORCE TO ACTIVATE THE CONTROLS SHALL BE NO GREATER THAN 5 LB. 3. LAVATORY FAUCET CONTROLS SHALL BE AUTOMATIC OR OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWIST OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LB. 8" A F F 0' - 7 " T O 35 " M I N . 0' - 5 " M A X VERTICAL ACTUATOR UNOBSTRUCTED TOE CLR. 0' - 6" MAX. 11" MIN. 27 " C A N E D E T E T I O N 9" M I N . C L R 36 " M A X . FO R C H I L D R E N WIDTH PER ELEVATIONS 4' - 2 " T Y P . B. O . RE F L E C T .SU R F A C E SOAP DISPENSER 36" MAX. FOR CHILDREN A.F.F. TO OPERABLE PARTS (INCLUDING COINSLOTS) OF ALL ACCESSORIES MIRROR MOUNTING HEIGHTS FOR CHILDREN HAND DRYER 0' - 4" MAX. SIDE FRONT 27 " C A N E D E T E T I O N 9" M I N . C L R NOTE: INSULATE HOT WATER & DRAIN PIPE. THERE SHALL BE NO SHARP OR ABRASIVE OBJECTS UNDER THE LAVATORY LAVATORY AND MIRROR ACCESSIBLE URINAL MIRROR 0' - 5 " M I N . FO R C H I L D R E N 36 " M A X . KNEE CLR 8" MIN. 25" MAX. 17" MIN. 27 " M I N . 29 " M I N . FO R C H I L D R E N 34 " M A X . , 2 9 " M A X . 18" MIN. AC C T . O . S E A T 17 " M A X . F O R 44 " M A X . 13 1/2" MIN. FLUSH CONTROL OR AUTOMATIC FLUSH VALVE 24" MIN.12" MIN. 36" MIN. FOR CHILDREN 15" TO 18" PARTITION OR FIXTURE 60" MIN. TO ACCESSIBLE TOILET 1-1/2"1-1/2" GRAB BAR TOE CLR. 0' - 6" MAX. 11" MIN. FO R C H I L D R E N ' S T O I L E T 15 " T O 1 7 " T . O . S E A T FL U S H C O N T R O L 36 " M A X . T O 12" MAX.42" MIN. FOR CHILDREN 7"-9" 54" MIN. 24" MIN. 48" CLEAR AT ACCESSIBLE TOILET WITH FRONT DOOR 60" CLEAR AT ACCESSIBLE TOILET COMPARTMENT WITH SIDE DOOR DI S P E N S E R F O R C H I L D R E N 14 " - 1 9 " TO B . O . O U T L E T O F T O I L E T P A P E R FO R C H I L D R E N 25 " - 2 7 " TOILET PAPER HOLDER GRAB BAR ACCESSIBLE TOILET A. F . F . T O TO P O F GR I P P I N G SU R F A C E UNOBSTRUCTED FORWARD REACH KNEE CLEARANCE HANDRAIL @ RAMP HANDRAIL @ WALKING SURFACES 34 " - 3 8 " 34 " - 3 8 " MIN. 1' - 0" MIN. 1' - 0" MIN. 0' - 1 1/2" MI N . 0' - 1 1 / 2 " X < 4 " MI N . 0' - 9 " 27 " M I N . MIN. 0' - 11" MIN. 0' - 8" MI N . 0' - 9 " MIN. 0' - 11" MIN. 0' - 8" 30" MIN. 25 " M A X . OBSTRUCTED FORWARD REACH 15 " M I N . 48 " M A X . 48 " M A X . 20" MAX. 44 " M A X . MAX. >20-25" UNOBSTRUCTED SIDE REACH 15 " M I N . 48 " M A X . MAX. 0' - 10" OBSTRUCTED SIDE REACH 48 " M A X . MAX. 0' - 10" 46 " M A X . 34 " M A X . MAX. >10-24" 34 " M A X . • • • * THE SPACE BETWEEN GRAB BAR AND PROJECTING OBJECTS: ABOVE= 12" MIN CLR BELOW= 1-1/2" MIN. CLR AT ENDS= 1-1/2" MIN. CLR • • • * THE SPACE BETWEEN GRAB BAR AND PROJECTING OBJECTS: ABOVE= 12" MIN CLR BELOW= 1-1/2" MIN. CLR AT ENDS= 1-1/2" MIN. CLR PER CBC 11B-308 FORWARD REACH: OBSTRUCTED 48" MAX. HEIGHT WITH UP TO 20" MAX HORIZONTAL OBSTRUCTION, OR 44" MAX. HEIGHT WITH >20" TO 25" MAX. HORIZONTAL OBSTRUCTION. SIDE REACH: OBSTRUCTED 48" MAX. HEIGHT WITH UP TO 10" MAX. DEPTH OF HORIZONTAL OBSTRUCTION, OR 46" MAX. WITH >10" TO 24" MAX. DEPTH HORIZONTAL OBSTRUCTION HORIZONTAL OBSTRUCTION UP TO 34" MAX. HEIGHT #132 RFI #132 RFI #132 RFI #132 RFI 2' - 6 " 0' - 6 " M A X . 30 " M A X A F F T O B U B B L E R F O R C H I L D R E N 36 " M A X A F F T O B U B B L E R FO R S T A N D I N G P E R S O N 38 " M I N . T O 4 3 " M A X A F F T O B U B B L E R S.S RAILING MOUNTED TO WELDED TRIPLE STUD WALL IF NOT IN WALLED ALCOVE WING WALL, ALCOVE, OR S.S. RAILING TO BE 32" MIN. WIDE AND AS DEEP AS DRINKING FOUNTAIN OPENING FORCE TO BE LESS THAN 5 POUNDS. WATER STREAM PARALLEL TO FRONT EDGE. SPOUT TO PROVIDE A FLOW OF WATER 4" HIGH OPER PARTS 6" MAX TO 8" MAX 15" MIN.5" MAX. 24 " M I N . A F F F O R C H I L D R E N 27 " M I N . A F F F O R K N E E S P A C E 18" MIN. TO 19" MAX. DRINKING FOUNTAIN 11" MIN 9" M I N . STANDING HEIGHT FOUNTAIN CBC 2016 11B-602 1' - 4" CLEAR 1' - 4" CLEAR 1' - 4" CLEAR 8"MI N 1 ' - 7 " ; M A X 1 ' - 9 " ACCESSIBLE HEIGHT FOUNTAIN STANDING HEIGHT FOUNTAIN FOR ACCESSIBLE FOUNTAIN: 36" MAX. A.F.F. TO BUBBLER (ADULT) 32" MAX. A.F.F. TO BUBBLER (CHILDREN) FOR STANDING PERSONS: 38" MIN. TO 43" MAX A.F.F. TO BUBBLER CBC 2016 11B-602 ACCESSIBLE HEIGHT PUSH BUTTON FOR BOTTLE FILLER 48" MAX. A.F.F. 1' - 4"1' - 4" 8" ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A0.5-1 DISABLE ACCESS COMPLIANCE MOUNTING HEIGHTS AND LOCATIONS 1/4" = 1'-0"14 DA- MOUNTING HEIGHT STANDARDS 1" = 1'-0"01 DA- DRINKING FOUNTAIN 1" = 1'-0"09 DA- DRINKING FOUNTAIN PLAN 1" = 1'-0"05 DA- DRINKING FOUNTAIN ELEVATION REV 5 - Bldg #101124388, Elect #20186445, Plumb #30149102, Mech #40140576 APPROVALS: PLNG - F. Arias BLDG - CSG POLICE - B. Martin PUBLIC WORKS - Y. SotoELECT/MECH/ PLUMB - CSG R SM - 1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 OPS2 SM - 1 SM - 1 SM - 1 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2 OPS2OPS2OPS2OPS2OPS2 SM-1 FOL-2FOL-2FOL-2FOL-2FOL-2 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 SM-1 SM-1 FOL-2 FOL-2 FOL-2 FOL-2 FOL-2FOL-2FOL-2FOL-2 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-2 LOCL-2 LOCL-2 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-2 LOCL-2 LOCL-2 LOCL-2 FE C FE C FE C FE C FE C DW SM - 1 SM - 1 SM - 1 SM - 1 SM - 1 SM - 1 SM - 1 SOPS SOPS SOPS SOPS SO P S SO P S SOPS SOPS SOPS SOPS SOPS SOPS SM - 2 SM - 1 SM-1 SM - 1 SOPS SM - 1 SM-1 SM - 1 FE C SM - 1 12345678910 C D E F G H Printer + copier Misc. storage MECH 003 ELEVATOR-ABAN. 007 FIRE AL.RM 006 MECH-ABAN. 008 ARCHIVES 002 STAFF OFFICE 001 OFFICE 012 OFFICE 013 STAFF MEETING ROOM 014 OFFICE 015 ALL GENDER RESTROOM 010 OFFICE 017 Work table Compact shelving Work tables Cabinets Locker & Cabinets Snack Machine Drink Machine Work table Cabinets 5 Drawer lateral file cabinets open shelves Book shelves Op e n S h e l v e s Op e n S h e l v e s STAFF BREAK ROOM 004 (E) ELEV. CONTROL RM. 005A OFFICE 016 Compact shelving ELECTRICAL 019 ELEV. CONTROL 018 Existing PAM CabinetEx i s t i n g M i c r o f i l m Ca b i n e t Ne w PA M Ca b i n e t New Cabinet 14' - 0" STORAGE 005 Trash/ Recycle Bin JANITOR. 023 Ca b i n e t s 12' - 0"5' - 10 1/2"17' - 3 1/4" ALL GENDER RESTROOM 011 STORAGE 022 #020 ASI #019 ASI #019 ASI #019 ASI A2.5-8 3 #020 ASI #104 RFI 1.FURNITURE PLANS ARE PROVIDED FOR REFERENCE ONLY ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A10.1-1 FURNITURE PLAN- BASEMENT (FOR REFERENCE ONLY) 1/8" = 1'-0"1 FP00 - BASEMENT FFE R SM - 1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 SM - 1 SM - 1 SM - 1 SM-1 FOL-2FOL-2FOL-2FOL-2FOL-2 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 SM-1 SM-1 FOL-2 FOL-2 FOL-2 FOL-2 FOL-2FOL-2FOL-2FOL-2 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-2 LOCL-2 LOCL-2 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-2 LOCL-2 LOCL-2 LOCL-2 FE C FE C FE C FE C FE C DW SM - 1 SM - 1 SM - 1 SM - 1 SM - 1 SM - 1 SM - 1 SM - 2 SM - 1 SM-1 SM - 1 SM - 1 SM-1 SM - 1 FE C SM - 1 INSERTION POINT (N ) (N) (N ) (N) J (N ) (N) (N ) (N ) (N) J (N ) J (N ) J (N ) (N ) (N)(N)(N)(N)(N) (N) J (N ) (N) (N ) (N)(N) J (N ) (N) 5' -6-1/2" 4' - 9 " 4' -0-1/2" 7' -11" 3' - 1 1 - 1 / 2 " 5' -6-1/2"5' 5' -10" 5'5' -6-1/2"5'5' -6-1/2"5' -6-1/2"5' 7' - 1 0 " 7' -8-1/2" 7' -6" 5' 3' -9" FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT TOP AROUND COLUMN. THE OVERHEAD/SLATWALL ARE SHORTER IN THIS OFFICE DUE TO THE COLUMN. FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT TOP AROUND COLUMN. THE OVERHEAD/SLATWALL ARE SHORTER IN THIS OFFICE DUE TO THE COLUMN. WS-1 WS-1 WS-1 CR-4 CR-4 WS-1 CT-1 WS-2 CT-1 SS-1B ST-3 WS-1 CT-1 WS-3 CT-1 WS-1 WS-1 SS-1B WS-1 WS-1 SS-1A CR-4 ST-3 CT-1 SS-1B CR-3 WS-2 CT-1 WS-1 SS-1B WS-3 CT-1 ST-3 CT-1 CR-4 CR-4 WS-4 SS-1B CT-1 SS-1B CT-1 WS-3 SS-1B WS-1 TR-1B SS-1B ST-3 ST-3 WS-3 SS-1A CT-1 SS-1B CT-1 TR-1C WS-1 ST-3 SS-1B CT-1 WS-3 ST-3 CT-1 WS-1 ST-3 WS-1 SS-1B CT-1 WS-1 WS-1 CT-1 CR-4 CT-1 SS-1B CR-3 CT-1 SS-1B SS-1B CR-3 ST-3 ST-2 CT-1 SS-1A CT-1 WS-3 ST-3 CT-1 ST-3ST-3 FL-1 CT-1 SS-1A SS-1A WS-3 ST-3 WS-1 CT-1 WS-3 SS-1B WS-1 SS-1A CT-1 CT-1 SS-1A WS-1 WS-1 SS-1B CT-1 CR-3 CT-1 ST-3 ST-3 TR-1D CT-1 SS-1A CT-1 WS-1 SS-1B SS-1A SS-1A CT-1 WS-1 SS-1A WS-1 ST-3 SS-1B WS-1 ST-4 CT-1 WS-1 ST-3 ST-3 WS-4 SS-1B ST-3 ST-3 CT-1 ST-4 WS-3 CT-1 WS-4 WS-3 WS-1 WS-2 WS-3 ST-3 CT-1 CT-1 CT-1 CT-1 CT-1 WS-1 WS-3 WS-1 WS-2 WS-4 CR-3 WS-1 WS-1 CT-1 WS-3 CR-4 SS-1A SS-1B CT-1 WS-3 CT-1 CR-3 CT-1 WS-3 WS-1 SS-1A FL-1 SS-1B ST-3 CT-1 WS-1 CR-3 ST-3 SS-1B CT-1 CT-1 SS-1B SS-1A WS-2 CT-1 WS-1 CT-1 WS-4 CT-1CT-1CT-1 CT-1CT-1 3' 2' - 8 - 1 / 2 " 7' -6-1/2" 4' 3' - 8 " 2' 9' -2-1/2" 5' - 4 " 3' 7' 7' 1' - 3 " 3' 6' -11" 3' -10"3' -10" 4' -11-1/2" 2' - 6 " 3' -7" 2' -5-1/2" 3' 3' - 2 " 6' -9" 4' -10" 3' 3' -0-1/2" 4' -3" 6' -5-1/2" 3' -10" 1 4C 2 4C 2 4C 3 3 4C 1 4C 2 4C 14C 2 1 1 22 3 4C4C 3 1 4C4C 2 3 3 2 1 1 1 3 2 3 2 1 4C 1 4C 3 2 4C 4C 3 4C 2 4C 1 1 2 4C 4C 1 4C 3 4C 1 4C 3 2 4C 22 2 3 3 4C3 4C 4C 3 3 4C 4C 3 2 4C 4C 3 1 4C 3 4C 4C 3 2 1 4C4C 3 3 2 1 4C 2 4C 4C 3 4C 3 3 4C 4C 3 2 2 4C 4C 1 1 1 11 3 1 1 1 4C 3 4C 3 4C2 3 4C 3 4C PAS.FS1.OS1 PAS.FS1.OS1 PAS.FS1.OS1 PAS.FS1.OS1 PAS.F S 1 7 . S S 3 PAS.X G V PAS.F S 1 7 . S S 3 PAS.X G V PAS.FS17.SS2PAS.XGV PAS.FS17.SS2PAS.XGV PAS . F S 2 . B N S 2 PAS . X G V PAS . F S 2 . B N S 2 PAS . X G V PAS.FS1.OS3 PAS.FS1.OS3 PAS.FS2.BNS4PAS.XGVPAS.FS2.BNS3PAS.XGV 15' ELECT-VIEWELECT-TYPE ELECTRICAL MCP FT FT FT FT FT FT +42" +42" +42" +42"+42" DW +18" +42" RF. +42" +42" +18" +18" P P P P P P J J J J J J J J J 12345678910 C D E F G H Printer + copier Misc. storage MECH 003 ELEVATOR-ABAN. 007 FIRE AL.RM 006 MECH-ABAN. 008 ARCHIVES 002 STAFF OFFICE 001 OFFICE 012 OFFICE 013 STAFF MEETING ROOM 014 OFFICE 015 ALL GENDER RESTROOM 010 OFFICE 017 Compact shelving Locker & Cabinets Snack Machine Drink Machine Op e n S h e l v e s STAFF BREAK ROOM 004 (E) ELEV. CONTROL RM. 005A OFFICE 016 Compact shelving ELECTRICAL 019 ELEV. CONTROL 018 Existing PAM Cabinet Existing Microfilm Cabinet STORAGE 005 Trash/ Recycle Bin JANITOR. 023 ALL GENDER RESTROOM 011 STORAGE 022 A2.5-8 3 SHOULD BE FOUR OUTLETS HERE DATA PROVIDED THROUGH FLOOR BOX FOLLOW FURNITURE VENDOR'S DIM FOR FOUR OUTLETS PANEL AND DATA RELOCATE FOUR OUTLETS PANEL AND DATA FOLLOW FURNITURE VENDOR'S DIM FOR FOUR OUTLETS PANEL AND DATA RELOCATE FOUR OUTLETS PANEL AND DATA FOLLOW FURNITURE VENDOR'S DIM FOR FOUR OUTLETS PANEL AND DATA 9' - 0 " 7' - 10" ALIGN W. C.L. OF COLUMN ALIGN W. C.L. OF COLUMN ALIGN W. C.L. OF COLUMN ALIGN W. C.L. OF COLUMN ALIGN WITH GRID ALIGN WITH GRID FC3 2D FC3 2D FC3 4D FC6 4D 9" 2' - 9 " ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A10.2-1 FURNITURE POWER/DATA PLAN- BASEMENT (FOR REFERENCE ONLY) 1/8" = 1'-0"1 FP00 - BASEMENT FFE POWER/DATA #009 ASI 1. REFER TO THIS SHEET FOR APPROXIMATE POWER AND DATA LOCATION. FOLLOW THE MOUNTING DIMENSION RULES IN SHEET A0.6-2 AND SPECS. IF WE REQUIRE FOR SPECIFIC LOCATION WE WOULD PROVIDE DIMENSIONS . 12345678910 C D E F G H D003D010 7' - 0 3/4" 8' - 8 3 / 4 " V. I . F 7' - 0 3 / 4 " V. I . F 1' - 8 " V.I.F 4' - 11 1/4" RETURN AIR CHASE D002D002 D002D002 D002D002 D002D002 D002D002 D004D004 D002 (R) STEPPED SEATING AREA FRIEND'S AREA STORAGE/MECHANICAL REFERENCE TEEN SPACE YOUTH SERVICES TECHNICAL SERVICES TEEN SPACE ACTIVITY TEEN SPACE OFFICE ADULT COMPUTER LAB D010 D035 #41 RFI INDICATES AREA OF SLAB ON GRADE DEMO AS REQUIRED BY PIT WALL SHORING REQUIREMENTS. SLAB ON GRADE DEMO EXTENT PER CONTRACTOR. #41 RFI #019 ASI #019 ASI #020 ASI #020 ASI #020 ASI #020 ASI MI N . 3' - 0 " MIN. 3' - 0" MIN. 3' - 0" MI N . 3' - 0 " #41.1 RFI WALL TYPE LEGEND EXISTING WALL, TO REMAIN EXISTING WALL, TO BE DEMOLISHED NEW WALL (E) WALL, REMOVED FINISHES TO STUDS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. COORDINATE WITH ALL OTHER DEMOLITION SHEETS. REFER TO SHEET A2.0-10, PROTECTION GENERAL NOTES, REFER TO SECTIONS: 02 4119.13 - SELECTIVE BUILDING DEMOLITION, 02 4296 - HISTORIC REMOVAL AND DISMANTLING NOTE SPECIFIC ITEMS TO BE REMOVED AND PROVIDED TO THE CITY/LIBRARY, RE: A2.0-13. (PLAQUES SHALL BE REMOVED WITH CARE AND PROVIDED TO THE CITY/LIBRARY. (R) ALL FURNITURE LEFT IN THE BUILDING INCLUDING BUT NOT LIMITED TO SHELVING, BUILT-IN CABINETS, DESKS, EQUIPMENT, APPLIANCES, BULLETIN BOARDS AND SIGNAGE. DURING DEMOLITION WORK, MAINTAIN COMPLIANCE WITH CALIFORNIA FIRE CODE CHAPTER 33. PROTECTED AREAS TO REMAIN. IF AREAS THAT ARE NOT SHEDULED TO BE REMOVED ARE DAMAGED, DOCUMENT AND NOTIFY THE ARCHITECT FOR HOW TO REPAIR. (R) ALL FLOOR FINISHES U.O.N. REFER TO DOOR SCHEDULE FOR DOORS TO BE SAVED AND REUSED. (R) ALL OTHER DOORS, FRAMES, AND HARDWARE. PROVIDE TEMP. SHORING FOR ESCAVATION OF SKYLIGHT WELLS. TRENCH FOR FLOOR BOXE 8" WIDE, TYP. REFER TO C-1.20 FOR MORE SITE DEMO ELEMENTS DEMOLITION NOTES: DEMOLITION PLAN LEGEND EXISTING FLOOR, SLAB, CURB, ETC, TO BE DEMOLISHED ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A2.0-0 DEMOLITION BASEMENT FLOOR PLAN KEYNOTE NO.KEYNOTE TEXT D002 (R) WALL D003 (R) CASEWORK D004 (R) PLUMBING FIXTURES AND PARTITIONS DEMO D010 (R) DEMO SLAB D035 FOR EXISTING WALLS REMAINED AT RESTROOMS, DEMO FINISH AND DRYWALL DOWN TO THE STUD AT THE RESTROOM INTERIOR SIDE 1/8" = 1'-0"1 (D) FPB - BASEMENT PLAN - DEMOLITION WH 1 2345678910 C D E F G H D035 SINK TO REMAIN SLAB TRENCH FOR FLOOR BOX SLAB TRENCH FOR FLOOR BOX A3.0-11 A3.0-1 4 A3.0-1 3 A3.0-1 2 12' - 0" PARTIALLY DEMOLISH (E) WALL TO ACCOMMODATE (N) OPENING DEMOLISH EXTERIOR GATE AND FENCES SLAB TRENCH FOR FLOOR BOX 8' - 9 " 7' - 1"V.I.F 4' - 10" V. I . F 6' - 1 1 1 / 2 " V. I . F 1' - 9 1 / 2 " DEMOLISH ALL EXISTING RESTROOM FINISHES. WALLS TO REMAIN U.O.N D004 D004 D002 D002 D007 D003 D002 D002 D002 D002 D002D002 D002D002 D002 D002 D004D004 D002D002 D002D002 6' - 1 1 3 / 4 " 8' - 1 1 1 / 4 " 7' - 3 1 / 2 " 6' - 2 1 / 2 " EQ EQ D003D003D003 D003 CHILDREN STACKS MAIN READING ROOM INFORMATIONS MEN RR.WOMEN RR. HISTORY ROOM REFERENCE OFFICE STAFF LOUNGESERVICE RESTROOMSTORAGE BOOK RETURN SOUTH ENTRANCE CHILDREN STAGE BOYS.GILRSMECH.STORAGE JAN. D010 D010 D011 1' - 4 3/4" 13' - 7" D035 D010 D020 D017 D017 D015 18' - 0" 18' - 0" 18' - 0" D010 D010 D018 D018 D029A D030 D032 D032 D032 D032 S.C.D. AND S.L.D. FOR SITE DEMO ELEMENTS D035 D035 D002AD035 D035 D035 VESTIBULE SORTING #59 RFI #59 RFI #52 RFI #019 ASI #019 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI D029B D029B D029B D029B #110 RFI #126 RFI A8.8-5 1 WALL TYPE LEGEND EXISTING WALL, TO REMAIN EXISTING WALL, TO BE DEMOLISHED NEW WALL (E) WALL, REMOVED FINISHES TO STUDS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. COORDINATE WITH ALL OTHER DEMOLITION SHEETS. REFER TO SHEET A2.0-10, PROTECTION GENERAL NOTES, REFER TO SECTIONS: 02 4119.13 - SELECTIVE BUILDING DEMOLITION, 02 4296 - HISTORIC REMOVAL AND DISMANTLING NOTE SPECIFIC ITEMS TO BE REMOVED AND PROVIDED TO THE CITY/LIBRARY, RE: A2.0-13. (PLAQUES SHALL BE REMOVED WITH CARE AND PROVIDED TO THE CITY/LIBRARY. (R) ALL FURNITURE LEFT IN THE BUILDING INCLUDING BUT NOT LIMITED TO SHELVING, BUILT-IN CABINETS, DESKS, EQUIPMENT, APPLIANCES, BULLETIN BOARDS AND SIGNAGE. DURING DEMOLITION WORK, MAINTAIN COMPLIANCE WITH CALIFORNIA FIRE CODE CHAPTER 33. PROTECTED AREAS TO REMAIN. IF AREAS THAT ARE NOT SHEDULED TO BE REMOVED ARE DAMAGED, DOCUMENT AND NOTIFY THE ARCHITECT FOR HOW TO REPAIR. (R) ALL FLOOR FINISHES U.O.N. REFER TO DOOR SCHEDULE FOR DOORS TO BE SAVED AND REUSED. (R) ALL OTHER DOORS, FRAMES, AND HARDWARE. PROVIDE TEMP. SHORING FOR ESCAVATION OF SKYLIGHT WELLS. TRENCH FOR FLOOR BOXE 8" WIDE, TYP. REFER TO C-1.20 FOR MORE SITE DEMO ELEMENTS DEMOLITION NOTES: DEMOLITION PLAN LEGEND EXISTING FLOOR, SLAB, CURB, ETC, TO BE DEMOLISHED ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A2.0-1 DEMOLITION FIRST FLOOR PLAN KEYNOTE NO.KEYNOTE TEXT D002 (R) WALL D002A (R) REPAIR/RECONST RUCTION OF EXISTING CHASE WALL FOR NEW TOILET CARRIAGES D003 (R) CASEWORK D004 (R) PLUMBING FIXTURES AND PARTITIONS DEMO D007 (R) EXISTING EXTERIOR WALL FOR NEW OPENING DEMO D010 (R) DEMO SLAB D011 (R) BOOK RETURN D015 (R) BIKE RACK D017 (R) PUBLIC TELEPHONE, AND CONDUIT AND WIRING D018 (R) DOOR AND TRANSOM FRAME D020 (R) DEMO DRINKING FOUNTAINS D029A (R) REMOVE EXISTING TILE, THINSET AND CONCRETE FILLER D029B (R) REMOVE CARPET AND CONCRETE FILLER D030 EXISTING RETURN/DISPLAY TO BE RESTORED D032 (R) WINDOW D035 FOR EXISTING WALLS REMAINED AT RESTROOMS, DEMO FINISH AND DRYWALL DOWN TO THE STUD AT THE RESTROOM INTERIOR SIDE 1/8" = 1'-0"1 (D) FP01- FIRST FLOOR PLAN- DEMOLITION #020 ASI #020 ASI FEC FE C A3.1-101 A3.4-1 12345678910 C D E F G H 1 A2.5-1 3 A2.5-2 2 A2.5-6 7 A2.5-5 4YOUTH STACKS 117 BOOKMOBILE ROOM 103 STAFF-WOMEN RESTROOM 104 STAFF MEN RESTROOM 105 MEN RR 110 WOMEN RR 111 JAN. RM 112 MECH. 113 ALL GENDER RESTROOM 114 ALL GENDER RESTROOM 115 ADULT STACKS 119 YOUTH STACKS 118 GREAT READING ROOM 101 I.T. 106 SORTING 123STORAGE 108 (E) PORTE COCHERE SOUTH ENTRY AREA A7.3-1 2 (E) ELEV. BOOKSTORE 109 0806 A2.5-6 14 115 101 102 103105 106 107 113 104 109 116 TODDLERS AND INFANTS 120 FAMILY ZONE 121 110 111 112 109 102 123 OFFICE 103A 120-E NURSING/SENSORY 116 1STG1-E 1STG2-E 123B-E ST4-E 103B-E C24a 1401 STORAGE 124 UP UPUP DN DN DN 1403 MEETING/COMMUNITY ROOM 102 A5.0-1 6 C24W A5.0-1 10 i102B A5.0-1 A3.1-1 4 A3.1-1 3 A3.1-1 2 A3.1-1 5 106 6' - 1 0 " 4' - 8 5 / 8 " A5.0-3 13 7' - 7 1/2" VESTIBULE 107 VESTIBULE 100 A5.0-1 2 A9.5-1A 16 A2.5-9 1A2.5-93 102C 102D 110 111 108 DN ST-01ST-02 ST-03 ST-04 C24a C23.6a C24a C24 F14 F14 C24 C24F14F14 F14 F14 F14 F14a C24 G26aG26a G26a C24 F14 C24 F14 C24 C24 C24 C24 C24a F14a G23a G23a G23a G23a C24a B24a F14a F14a F14a F14a F14a C24a F14a B24a F14aF14a F14a B26a B24a C24 C24 B24a B24a G26a 102A 103A 102B C.L.2' - 2 " 107 101 i122a iI2b 4' - 7 1/2" DN 115 F14 F14 C14a B26 F14 F14 C24a EXISTING STAIRS, SEE HISTORIC BUILDING CODES PER NOTE ON A0.4-0 EXISTING STAIRS, SEE HISTORIC BUILDING CODES PER NOTE ON A0.4-0 FLOOR ABOVE 1059 2307 1407 2307 G24a G24a G24a 124 B24 C14a 103-I 100 KID'S AREA N.A.P. A2.5-1 7 A2.5-1 9 123C 1 A5.0-5 1 0317 0317 A2.6-11 E24a G1.2-37 G1.2-46 G1.2-4 8 9 G1.2-4 10 108 1017 1017 1017 1017 1018 1018 10181018 1018 1018 1017 1017 1017 1017 1018 1018 1018 1018 10171017 1018 1018 113 F14 F14 V.I.F 28' - 5" 09420942 09420942 C24a C B24a G1.2-8 3 4 G1.2-8 F14 ADD 5/8" GYP BOARD ON WALL TO CONCEAL ANGLE PLATE AND WEDGE ANCHOR #8 RFI 8' - 3 1 / 2 " 3' - 0 " A8.8-210 D24a F14a C24a #17 RFI #17 RFI #17 RFI 27' - 7"17' - 7"17' - 5"18' - 0 3/4"18' - 4 1/2"18' - 0 3/4"17' - 5"17' - 7"27' - 6 1/4" 1074 G24a F12 F10 F10 F14 0943 0943 #013 ASI #013 ASI #013 ASI #013 ASI #013 ASI 105 104 #59 RFI #59 RFI #52 RFI #019 ASI #019 ASI A1.2-2 3 A1.2-26 114 F14a F14a F14a C24a B26a F12F10 F12 112F14a F14 C23.6a F14a F14a F14a F14a C24a C24a F10 F14 F10 F10 F10 F10 F10 F10 F10 F10 F10F12 F10 F12 F10 F10 F12 C14a F12 F14 F12 F10 F10 F10 0943 0943 F10 #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #013 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI A5.0-3 3 #020 ASI #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #110 RFI #114 RFI #64 RFI #64 RFI F12 108-A #022 ASI #126 RFI FIREPLACE ROOM 122 25' - 5" NEW LAYER OF GYP BOARD APPLIED TO EXISTING WALL ON WEST SIDE LEVEL 4 GYP BOARD SURFACES #116 WALL TYPE LEGEND EXISTING WALL, TO REMAIN NEW WALL 1-HOUR FIRE RATED WALL NEW FURRED WALL 1. REFER TO SHEET C1.2-0 FOR DETAILED DEMO ITEMS SHEET NOTES: ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 A2.4-2 FLOOR PLAN- FIRST FLOOR 1/8" = 1'-0"1 FP01- FIRST FLOOR PLAN 523 W 6 th Street, Suite 1013, Los Angeles, CA 90014 KEYNOTE NO.KEYNOTE TEXT 0317 (N) NEW SLAB FOR COMPACT SHELVING, SEE 2/S7.01 0806 INTERIOR STOREFRONT SYSTEM 0942 RECESSED PICTURE RAIL AT +7'-6"FF 0943 LEVEL 4 GYPSUM BOARD SURFACES FOR EXISTING WALLS TYP, U.N.O. SEE SPECS #09 2900 3.5 1017 CORNER GUARD 1018 BUMPER RAIL 1059 CHUTE 1074 TWO LAYERS OF TYPE X GYPSUM BOARD ATTACHED TO EXISTING WALL TO MEET 1HR FIRE RATING PER UL DESIGN V497 1401 (E) ELEVATOR MODERNIZATION AND REPAIR 1403 (E) DUMBWAITER TO BE REMAIN. DOOR TO BE MADE LOCKABLE 1407 PASSENGER ELEVATOR 2307 EXHAUST DUCT TO ROOF (E) REV #DESCRIPTION DATE #8 RFI 10.18.2024 #003 ASI 03.31.2025 #17 RFI 11.27.2024 #013 ASI 02.12.2025 #52 RFI 02.14.2025 #59 RFI 02.12.2025 #019 ASI 03.28.2025 #020 ASI 03.28.2025 #64 RFI 04.08.2025 #110 RFI #114 RFI 04.15.2025 #116 RFI 06.12.2025 #126 RFI 05.07.2025 #022 ASI 05.02.2025 #52 RFI 12345678910 C D E F G H YOUNG ADULT 211 HISTORY 222 STUDY 202 VESTIBULE SEATING 200A STUDY 201 ALL GENDER RESTROOM 2T1 ALL GENDER RESTROOM 2T2 STAFF RESTROOM 2T3 ADULT STACKS 200 STAIR 3 2S3 STUDY 220 STAFF MEETING ROOM 221 ACC. RAMP OPEN TO BELOW JAN.RM 217 STORAGE 200B OFFICE 223 OFFICE 226 MAKER STORAGE 216 STAFF OFFICE 224 YA STUDY BOOTH 211A OFFICE 225 ELEC. RM. 218 ST-01ST-02 ST-03ST-05 ALIGN F.O.F VIDEO RECORDING BOOTH 214 VIDEO EDITING BOOTH 213 MAKER SPACE 212 13' - 2 1/2" 5' - 6 " 6' - 1 1 " 9' - 5 3 / 4 " 35 ' - 1 3 / 4 " ALIGN F.O.F. 13' - 7 1/4"7' - 11 1/4" ALIGN F.O.F. 2' - 2 1 / 4 " 17' - 2 1/2"10' - 6"8' - 2 1/2"2' - 2 1/2"8' - 5"1' - 8 1/4"8' - 5 1/2" ALIGN F.O.F. 2' - 1 1/2"17' - 9 1/2" 5' - 8 3 / 4 " 5' - 0 1 / 2 " 11 ' - 6 3 / 4 " ALIGN F.O.F. 1' - 7"4' - 8"11' - 4 1/4"5' - 3" ALIGN F.O.F. W. EXISTING BULKHEAD FINISH ALIGN F.O.F. ALIGN F.O.F. ALIGN F.O.F. ALIGN F.O.F. ALIGN F.O.F. 4' - 3 1/2"8' - 4 1/4" 9' - 7 " V. I . F . 3' - 2 1 / 4 " 11 ' - 8 1 / 2 " 18' - 1 1/2"9' - 3 3/4"26' - 5"6' - 1 1/2"4' - 5 3/4" ALIGN F.O.F.W. EXISTING BULKHEAD FINISH V. I . F . 5' - 5 3 / 4 " 1' - 0 3 / 4 " 4' - 5 1/4" ALIGN F.O.F. ALIGN F.O.F. 1' - 5 1 / 4 " 2' - 3 1 / 4 " 15' - 1" 4' - 5 " ALIGN F.O.F. 1' - 9 3 / 4 " 6' - 3 3 / 4 " V. I . F . 5' - 5 " 6' - 9 3/4"9' - 11 1/4" ALIGN F.O.F. ALIGN F.O.F. ALIGN F.O.F. 1' - 5 1/4"11" ALIGN F.O.F. #198 RFI #198 RFI #198 RFI #198 RFI #198 RFI #198 RFI #198 RFI #198 RFI 4' - 7 3/4" #214 RFI ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 A2.4-8 DIM CONTROL PLAN - SECOND FLOOR REV #DESCRIPTION DATE #64 RFI 04.08.2025 #198 RFI 06/11/2025 #214 RFI 0 1/8" = 1'-0"2 FP02 - SECOND FLOOR DIM CONTROL PLAN #64 RFI 45678 8 HH COLORED CONCRETE PAVING S.L.D. FOR EXTENT (E) PORTE-COCHERE STRUCTURE 2 A2.5-1 PLANTED AREA S.L.D. FOR EXTENT (E) CONCRETE PAVING (E) PARTIAL HEIGHT WALL A3.1-1 3 A3.1-1 5 13' - 6" 2' - 6"6' - 4 1/2" 3"MIN. FROM EDGE OF CONCRETE OPENING TO HSS COLUMN. TYP ALL SIDES 1' - 1 1 / 2 " 3' - 0"2' - 6" 1' - 11"12' - 0"3' - 0"12' - 1" CUSTOM SECURITY SCREEN DOOR ACTUATOR AND CARD READER BOOK DROP. SEE 9/A2.5-1 WINDOW IN (E) DOOR OPENING SECURITY GRILLE OPERATION BOX MICRO-COIL SECURITY GRILLE STOREFRONT ENTRANCE (E) EXHAUST VENT. NEW FINISH. TYP. H.S.S. REINFORCING FRAME- SEE STRUCTURAL DWGS. PRECAST CONC. SILL ROOF DRAIN AND OVERFLOW LEADERS. SEE CIVIL FOR UNDERGROUND CONNECTION LOCATION METAL SECURITY FENCING, FULL HEIGHT STEEL H.S.S. GATE SUPPORT. SEE STRUCTURAL 3"MIN. 1 A2.5-1 1 A3.6-22 A3.6-2 SLAB INFILL. SEE STRUCTURAL DWGS. 4' - 1 0 1 / 2 " DOOR ACTUATOR MOTOR ATTACHED TO ROOF FRAMING ABOVE SLOPE 2% MAX 30"X48" 30"X48" 30"X48" 30"X48" 8 A2.5-1 BOOK DROP. SEE 7/A2.5-1 G1.2-4 9 2 G1.2-8 A8.8-210 A1.2-2 3 21 ' - 8 1 / 4 " 2' - 6 1 / 2 " FIRST FLOOR-119' - 10 1/2" 45678 2 A2.5-1 1 A3.6-2 2 A3.6-2 BOOK DROP STOREFRONT SYSTEM AND DOUBLE DOOR ALUMINUM FORMED PANEL SYSTEM MARBLE SILL. TYP. 11 ' - 7 " 2' - 7 " 9' - 0 " 2' - 6"6' - 4 1/2"3' - 0"2' - 6"12' - 1"3' - 0" SCREEN IN RESTORED OPENINGS 12' - 0" INFILL WALL TO MATCH (E) ALIGN 1' - 11" ALIGN METAL PANELS TO MARBLE JOINTS 4 G1.2-8 OPERATION BOX ALUMINUM FORMED PANEL SYSTEM RECESSED LED STRIP LIGHTING. TYP. SEE ELECTRICAL DWGS. ACOUSTICAL CEILING TILE (E) EXTERIOR WALL AL I G N T O ST O R E F R O N T C L 3"Ø DRAIN AND OVERFLOW LEADERS. OFFSET PIPES INTO CORNER SECURITY GRILLE OPERATION BOX T.O.P. B.O.FRMG BOOK DROP METAL CLAD SYSTEM. TYP. 5/8" GYP. SHEATHING. TYP. METAL STUD FRAMING. TYP. SECURITY GRILLE 11 ' - 7 " 48 " M A X . T O O P E R A B L E P A R T A8.8-2 1 B.O.FRMG ACOUSTICAL CEILING TILE A8.5-2 2 T.O. PARAPET BEYOND 9' - 4 1 / 4 " ROOF DRAIN PIPE BEYOND. SEE PLUMBING OVERFLOW PIPE BEYOND. DRAIN OUT 18" A.F.F. 7' - 10 1/2" FIRST FLOOR-119' - 10 1/2" H CONCRETE PAVING ., S.L.D. CONCRETE SLAB PATCH FOR (E) SIDEWALK ELEVATOR DOOR, S.S.D. G.W.B. SOFFIT S.S. HEADER, S.S.D. SUSPENDED WD SLAT CEILING ALUMINUM STOREFRONT LED STRIP LIGHTING BOOK DROP SECURITY GRILLE 3" BI-FUNCTIONAL DUAL OUTLET ROOF DRAIN W/OVERFLOW. 100C FROET BY ZURN 9' - 0 " 2' - 0 " 7' - 0 " A8.8-2 4 A8.8-2 5 11 ' - 7 " (E) EXTERIOR MARBLE CLAD 1/8" / 12" 10 ' - 3 1 / 2 " #143 RFI EXISTING WALL METAL PANEL OVER METAL STUD WALL METAL PANEL OVER METAL STUD WALL W/ INT. GYP. WALL TYPE LEGEND MA X . A . F . F . 4' - 0 " FIRST FLOOR-119' - 10 1/2" H 9' - 0 " 8 A2.5-1 FIRST FLOOR-119' - 10 1/2" 6 A2.5-1 MA X . A . F . F . 4' - 0 " ALUMINUM FORMED PANEL SYSTEM. WRAP O/PARAPET 2% S L O P E 2% SLOPE SINGLE-PLY TPO ROOFING. SLOPE TO DRAIN 3" BI-FUNCTIONAL DUAL OUTLET ROOF DRAIN W/OVERFLOW. 100C FROET BY ZURN ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A2.5-1 ENLARGED PLANS SOUTH ENTRY KEYNOTE NO.KEYNOTE TEXT 1/4" = 1'-0"3 SOUTH ENTRY/PORTE-COCHERE 1/4" = 1'-0"4 SOUTH ENTRY PARTIAL ELEVATION 1/4" = 1'-0"5 SOUTH ENTRY PORTAL REFLECTED CEILING PLAN 1/2" = 1'-0"1 SOUTH PORTAL LONGITUDINAL SECTION 1/2" = 1'-0"2 SOUTH PORTAL TRANSVERSAL SECTION 1.ALL DIMENSIONS ARE TO THE FACE OF THE WALL U.N.O. 1/2" = 1'-0"6 IE - BOOK DROP - SOUTH ENTRY 1/2" = 1'-0"7 IE - BOOK DROP - VESTIBULE 107 1/2" = 1'-0"8 IE - BOOK DROP - VESTIBULE 107 1/2" = 1'-0"9 EL - BOOK DROP - SOUTH ENTRY SOUTH ENTRY AREASORTING 123 1/4" = 1'-0"10 SOUTH ENTRY PORTAL ROOF PLAN 67 F G H A2.5-2 7 1 3 5 4 A7.3-1 STORAGE 108 i122B F14 F14a G24a 108 C24 C24 1048 A5.0-1 13 F14 F14 F14F14F14 F14 15' - 0" i122a 3' - 1 1/4" 6' - 0 1 / 2 " 3' - 0 1 / 2 " 2' - 8 3/4" G1.2-46 G1.2-4 10 #020 ASI #020 ASI FIREPLACE ROOM 122 i122aDTOPEN TO WALL SHELVING OPEN TO WALL SHELVING 15' - 0"3' - 1 1/4" 6' - 1 1 / 2 " 1' - 11 1/2" 09110911 1 A9.6-3 #023 ASI 11' - 0" OPEN TO SPACE BEYOND 6' - 0"EQ EQ iI2bDT 7' - 7 1 / 2 " DT ELEVATION F ROOM INSIDE THE ROOM 122 iI2b 09110911 7' - 6 " OPEN TO WALL SHELVING 18' - 0 1/2" 0911 1 A9.6-3 OPEN TO WALL SHELVING 6' - 0 1/2" 0911 1 A9.6-3 WINDOW LEGEND DT 1/4" TEMPERED FLOAT GLASS ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A2.5-2 ENLARGED FLOOR PLANS FIREPLACE ROOM KEYNOTE NO.KEYNOTE TEXT 0911 4"H WALL BASE, SEE FINISH SCHEDULE 1048 ELECTRIC FIREPLACE. FLUSH WITH WALL SURFACE 1/4" = 1'-0"2 FP01- FIRST FLOOR PLAN - FIREPLACE RM 1/4" = 1'-0"7 IE - 122 FIREPLACE RM ELEVATION NORTH 1/4" = 1'-0"5 IE - 122 FIREPLACE RM ELEVATION EAST 1/4" = 1'-0"3 IE - 122 FIREPLACE RM ELEVATION SOUTH 1/4" = 1'-0"1 IE - 122 FIREPLACE RM ELEVATION WEST 12" = 1'-0"8 FIREPLACE RM PERSPECIVE WINDOW SCHEDULE - INTERIOR A2.5-2 WIN #LENGTH HEIGHT GLAZING TYPE FRAME MATERIAL FRAME FINISH SHADE TYPE i122a 2' - 2"7' - 1 1/2"DT AL PT N/A i122B 15' - 7"11' - 8"DT AL PT N/A #020 ASI #020 ASI #023 ASI #023 ASI #023 ASI 23 F I.T. 106 STAFF MEN RESTROOM 105 STAFF-WOMEN RESTROOM 104 A2.5-6 12 9 A2.5-6 8 2 5' - 0 5 / 8 " 7' - 9 1/2" 3' - 0" 5' - 7 1/2" 17" MIN. 111 F14a F14a F14a F14a F14a C24a F14a F14a B24a C24a 106 5 4 F14a 12071207 22082208 1205A 1249 1249 7' - 6 " 1' - 8 3 / 4 " 16' - 10 3/4" 1209B 2203 2208 18" MAX. 17" MIN. 18" MAX. DOOR PERMITTED TO SWING OVERE HATCHED PORTION OF MANEUVERING SPACE 1205A 1208F 1208E 1205A CLR. 60" MIN 5' - 1 1/4"5' - 8 1/2" 1205A 0911 1205A 0903A 2208 5' - 8 5/8" 0911 1207 1205A 0903A 1249 22083' - 4 " 1066 22082206B 0903A 1207 1249 0911 2206B 0903A 0911 1249 1207 1209B 0903A 1249 2208 1205A 2203 1066 3' - 4 " 0903A 9 H A2.5-6 10 6 TYP. ALL GENDER RESTROOM 115 ALL GENDER RESTROOM 114 D010D010 22082208 13 1207 1207 1249 115 1211 1211 1249 ALIGN ALIGN C24a 3 1/4" 7' - 7 1/2"1' - 10" F14a F14a B26a 1205A 1205A 12" MIN A2.5-6 13 OPP. 10OPP. 6 OPP. 3 3 OPP. 1208E 1208E 1210 1210 RESTROOM 114&115 ARE FOR CHILDREN; REFER A0.5-1 FOR DISABLE ACCESS COMPLIANCE MOUNTING HEIGHTS FOR CHILDREN #129 H 0903A 2208 1207 1211 1249 1205A 0911 #129 #129 RESTROOM 114&115 ARE FOR CHILDREN; REFER A0.5-1 FOR DISABLE ACCESS COMPLIANCE MOUNTING HEIGHTS FOR CHILDREN 2208 0911 1205A 1208E OPP. 1208E #129 #129 RESTROOM 114&115 ARE FOR CHILDREN; REFER A0.5-1 FOR DISABLE ACCESS COMPLIANCE MOUNTING HEIGHTS FOR CHILDREN INTERIOR WALL FINISH LEGEND MB MARKERBOARD AWP-1 TACKABLE ACOUSTIC WALL PANEL PT-2 PORCELAIN TILE 4' HEIGHT TYP. FRP FIBER REINFORCED PLASTIC PANEL WP WOOD VENEER PANEL P-1 PAINT P-5 PAINT P-2 PAINT P-6 PAINT P-3 PAINT P-4 PAINT #97 RFI 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. REFER TO SHEET A0.2 FOR ARCHITECTURAL SYMBOLS, WALL TYPE LEGEND, ABBREVIATIONS. COORDINATE ALL ACCESSIBILITY COMPLIANCE REQUIREMENTS, SEE SHEET A0.5 SERIES. REFER TO ENLARGED PLANS FOR ADDITIONAL DIMENSIONS. REFER TO SHEET A9.0 SERIES FOR INTERIOR PARTITION TYPES AND DETAILS. REFER TO SHEET A4 SERIES FOR FINISH PLANS. ALL EXTERIOR AND INTERIOR STEEL EXPOSED TO PUBLIC SHALL BE A.E.S.S. REFER TO A-- A.E.S.S. CATEGORIES. COORDINATE PENETRATIONS WITH STRUCTURAL, MECHANICAL, PLUMBING, CIVIL, ELECTRICAL AND TELECOM. MECHANICAL, LIGHTING, A/V FIXTURES SHOWN FOR COORDINATION. S.M.D,. S.E.D., S.T.D. FOR COMPLETE QUANTITY AND EXTENTS OF FIXTURES. NOTIFY OWNER'S REP AND ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO PROCUREMENT AND INSTALLATION. REFER TO SHEET A2.6-1 FOR DOOR SCHEDULE. REFER TO A0.3-0 FOR GENERAL NOTES. PROVIDE BACKING IN ALL WALLS AS REQUIRED FOR SHELVES, CABINETS, BRACKETS, GRAB BARS, HANDRAILS, ETC. SEE A9.01 SEE A0.6-1 FOR TYPICAL RULES FOR DETERMINING HEIGHTS AND LOCATIONS SEE A0.5-1 FOR DISABLE ACCESS COMPLIANCE MOUNTING HEIGHTS AND LOCATIONS ALIGN NEW WALL FINISH WITH EXISTING WALL FINISH SHEET NOTES: ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A2.5-6 ENLARGED FLOOR PLANS RESTROOMS KEYNOTE NO.KEYNOTE TEXT 0903A PORCELAIN TILE, T.O.H 4'-4" A.F.F., SEE A5.0-0 FOR ADDITIONAL INFO 0911 4"H WALL BASE, SEE FINISH SCHEDULE 1066 PHENOLIC TOILET PARTITION 1205A GRAB BAR, 36" LENGTH BACK BAR, 42" LENGTH SIDE BAR, PROVIDE BACKING 1207 ELECTRIC HAND DRYER 1208E TOILET PAPER & SEAT-COVER DISPENSER, RECESSED, RECESSED, ON RIGHT SIDE, COMBO UNIT FOR ACCESSIBLE 1208F TOILET PAPER & SEAT-COVER DISPENSER, PARTITION MOUNT, SERVES BOTH COMPARTMENTS, WOMEN'S COMBO UNIT 1209B WALL MOUNTED URINAL PARTITION 1210 FOLD-DOWN BABY CHANGER 1211 SOAP DISPENSER 1249 MIRROR, SEE ELEVATIONS FOR DIMENSIONS 2203 URINAL, S.P.D. 2206B LAVATORY, RAMP SINK, S.P.D. COUNTERTOP MOUNTED FAUCET, SOAP DISPENSER AND HAND DRYER 2208 PLUMBING, S.P.D. D010 (R) DEMO SLAB D017 (R) PUBLIC TELEPHONE, AND CONDUIT AND WIRING 1/2" = 1'-0"7 ENLARGED ADA-GN AND STAFF RESTROOMS 1ST FLOOR 1/4" = 1'-0"9 IE 104 (N) STAFF WOMENS - EAST 1/4" = 1'-0"12 IE 104 (N) STAFF WOMENS - NORTH 1/4" = 1'-0"2 IE 104 (N) STAFF WOMENS - WEST 1/4" = 1'-0"11 IE - 105 (N) STAFF-M - NORTH 1/4" = 1'-0"8 IE - 105(N) STAFF - M - EAST 1/2" = 1'-0"14 ENLARGED ALL GENDER RESTROOM YOUTH (1ST FLOOR) 1/4" = 1'-0"10 IE-114 & 115 ALL GENDER RESTROOMS - EAST 1/4" = 1'-0"6 IE-114 & 115 ALL GENDER RESTROOMS - SOUTH 1/4" = 1'-0"5 IE 104 (N) STAFF WOMENS - SOUTH 1/4" = 1'-0"1 IE - 105 (N) STAFF - M - WEST 1/4" = 1'-0"4 IE - 105 (N) STAFF -M -SOUTH 1/4" = 1'-0"13 IE-114 & 115 ALL GENDER RESTROOMS -NORTH 1/4" = 1'-0"3 IE-114 & 115 ALL GENDER RESTROOMS - WEST #130.1 RFI #130.1 RFI #130.1 RFI #130.1 RFI #130.1 RFI FE C 89 G H ALL GENDER RESTROOM 2T2 ALL GENDER RESTROOM 2T1 STAFF RESTROOM 2T3 A2.5-72 A2.5-7 7 1 3 4 8 2T3 65 1207 2208 1207 B24a 11' - 0 3/4" 1205A1208E 2T2 1208D 1208E2208 1205A1205A 18" CLR. 11"1' - 5 1/4" 2208 1207 A2.5-75OPP. 3OPP. 1 7 OPP. OPP. 2208 2T1 F14a B24a B24a F14a B24a B24a #198 RFI#198 RFI #198 RFI #198 RFI #198 RFI CLEAR 7' - 8 1/2" CL E A R 7' - 1 1 1 / 4 " CL E A R 7' - 1 1 1 / 4 " CLEAR 8' - 4 1/2" CLEAR 7' - 11 3/4" CL E A R 7' - 1 1 1 / 4 " #198 RFI #198 RFI #198 RFI 1205A 2208 0911 1208E 1249 0911 2206B 0903A H 1249 0911 2208 1207 3' - 4 " 1205A INTERIOR WALL FINISH LEGEND MB MARKERBOARD AWP-1 TACKABLE ACOUSTIC WALL PANEL PT-2 PORCELAIN TILE 4' HEIGHT TYP. FRP FIBER REINFORCED PLASTIC PANEL WP WOOD VENEER PANEL P-1 PAINT P-5 PAINT P-2 PAINT P-6 PAINT P-3 PAINT P-4 PAINT #97 RFI 3' - 4 " 0903A 3' - 4 " 1205A 1249 0903A 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. REFER TO SHEET A0.2 FOR ARCHITECTURAL SYMBOLS, WALL TYPE LEGEND, ABBREVIATIONS. COORDINATE ALL ACCESSIBILITY COMPLIANCE REQUIREMENTS, SEE SHEET A0.5 SERIES. REFER TO ENLARGED PLANS FOR ADDITIONAL DIMENSIONS. REFER TO SHEET A9.0 SERIES FOR INTERIOR PARTITION TYPES AND DETAILS. REFER TO SHEET A4 SERIES FOR FINISH PLANS. ALL EXTERIOR AND INTERIOR STEEL EXPOSED TO PUBLIC SHALL BE A.E.S.S. REFER TO A-- A.E.S.S. CATEGORIES. COORDINATE PENETRATIONS WITH STRUCTURAL, MECHANICAL, PLUMBING, CIVIL, ELECTRICAL AND TELECOM. MECHANICAL, LIGHTING, A/V FIXTURES SHOWN FOR COORDINATION. S.M.D,. S.E.D., S.T.D. FOR COMPLETE QUANTITY AND EXTENTS OF FIXTURES. NOTIFY OWNER'S REP AND ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO PROCUREMENT AND INSTALLATION. REFER TO SHEET A2.6-1 FOR DOOR SCHEDULE. REFER TO A0.3-0 FOR GENERAL NOTES. PROVIDE BACKING IN ALL WALLS AS REQUIRED FOR SHELVES, CABINETS, BRACKETS, GRAB BARS, HANDRAILS, ETC. SEE A9.01 SEE A0.6-1 FOR TYPICAL RULES FOR DETERMINING HEIGHTS AND LOCATIONS SEE A0.5-1 FOR DISABLE ACCESS COMPLIANCE MOUNTING HEIGHTS AND LOCATIONS ALIGN NEW WALL FINISH WITH EXISTING WALL FINISH SHEET NOTES: ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 A2.5-7 ENLARGED FLOOR PLANS RESTROOMS KEYNOTE NO.KEYNOTE TEXT 0903A PORCELAIN TILE, T.O.H 4'-4" A.F.F., SEE A5.0-0 FOR ADDITIONAL INFO 0911 4"H WALL BASE, SEE FINISH SCHEDULE 1205A GRAB BAR, 36" LENGTH BACK BAR, 42" LENGTH SIDE BAR, PROVIDE BACKING 1207 ELECTRIC HAND DRYER 1208D TOILET PAPER & SEAT-COVER DISPENSER, RECESSED, RECESSED, ON LEFT SIDE, COMBO UNIT FOR ACCESSIBLE 1208E TOILET PAPER & SEAT-COVER DISPENSER, RECESSED, RECESSED, ON RIGHT SIDE, COMBO UNIT FOR ACCESSIBLE 1249 MIRROR, SEE ELEVATIONS FOR DIMENSIONS 2206B LAVATORY, RAMP SINK, S.P.D. COUNTERTOP MOUNTED FAUCET, SOAP DISPENSER AND HAND DRYER 2208 PLUMBING, S.P.D. 1/2" = 1'-0"12 ENLARGED RESTROOMS 2ND FLOOR 1/4" = 1'-0"4 IE 2T1 WOMEN RR - SOUTH 1/4" = 1'-0"8 IE 2T1 WOMEN RR -NORTH 1/4" = 1'-0"2 IE 2T1 WOMEN RR - WEST 1/4" = 1'-0"6 IE 2T1 WOMEN RR - EAST 1/4" = 1'-0"7 IE - 2T3 STAFF RR - NORTH 1/4" = 1'-0"3 IE - 2T3 STAFF RR - SOUTH 1/4" = 1'-0"5 IE - 2T3 STAFF RR - EAST 1/4" = 1'-0"1 IE - 2T3 STAFF RR - WEST RESTROOM ACCESSORIES SCHEDULE KEYNOTE NO.KEYNOTE TEXT MODEL . 1066 PHENOLIC TOILET PARTITION SEE SECTION 102113 1205A GRAB BAR,36" LENGTH BACK BAR, 42" LENGTH SIDE BAR, PROVIDE BACKING BOBRICK B-5806 x 36 (BACK); B5-806 x 42 (SIDE) 1205B GRAB BAR, 42" LENGTH BOTH SIDES, PROVIDE BACKING BOBRICK B5-806 x 42 (SIDE) 1207 ELECTRIC HAND DRYER PINNACLE SURFACE MODEL P3-12S 1208D TOILET PAPER & SEAT-COVER DISPENSER, RECESSED, ON LEFT SIDE, COMBO UNIT FOR ACCESSIBLE BOBRICK B-3091 1208E TOILET PAPER & SEAT-COVER DISPENSER, RECESSED, ON RIGHT SIDE, COMBO UNIT FOR ACCESSIBLE BOBRICK B-3092 1208F TOILET PAPER & SEAT-COVER DISPENSER, PARTITION MOUNT, SERVES BOTH COMPARTMENTS, WOMEN'S COMBO UNIT BOBRICK B-357 1208J TOILET PAPER & SEAT-COVER DISPENSER, PARTITION MOUNT, FLUSH AGAINST PARTITION ON ONE SIDE, COMBO UNIT FOR ACCESSIBLE BOBRICK B-30919 1209B WALL MOUNTED URINAL PARTITION SEE SECTION 10 2113 1210 FOLD-DOWN BABY CHANGER KOALA KB310-SSRE 2206B LAVATORY, RAMP SINK, S.P.D. COUNTERTOP MOUNTED FAUCET, SOAP DISPENSER AND HAND DRYER SEE PLUMING DRAWINGS #48 RFI #48 RFI #48 RFI #48 RFI #48 RFI#48 RFI #48 RFI #48 RFI REV #DESCRIPTION DATE #48 RFI 02.12.2025 #198 RFI 06/11/2025 #198 RFI BUILDING DOOR TYPES TYPE A TYPE AA TYPE C TYPE CC SIDELITE AS SCHEDULED. SIDELITE AS SCHEDULED. TYPE F TYPE G2 ALL TYPE CENTER HEIGHT OF HAND- ACTIVATED DOOR OPENING HARDWARE BETWEEN 34"-44" AFF. 2' - 1 0 " 3' - 4 " TYPE G1 TYPE X A. F . F . 4' - 1 " ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A2.6-1 DOOR SCHEDULE DOOR SCHEDULE DOOR NUMBER DOOR TYPE DOOR GLAZING TYPE FRAME DETAILS REMARKSWIDTHHEIGHTMATERIALFINISHMATERIALFINISHHEADJAMBSILLHARDWARE G1 G2 8' - 1"8' - 0"STL PTD -STL PTD 30 TRASH ENCLOSURE GATE, DROP CANE BOLT, PAD LOCKS G2 G2 8' - 1"8' - 0"STL PTD -STL PTD 30 TRASH ENCLOSURE GATE, DROP CANE BOLT, PAD LOCKS G3 B 3' - 0"7' - 6"STL PTD -STL PTD 11/A1.2-1 15/A1.2-1 9/A1.2-1 31 001 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 13 002 A 3' - 0"6' - 8"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 19 GASKETING 002A A 3' - 0"7' - 0"HM PTD -HM PTD 02/A9.1-1 04/A9.1-1 01/A9.1-1 02 003 AA 6' - 0"7' - 0"HM PTD -HM PTD 02/A9.1-1 04/A9.1-1 01/A9.1-1 37 03ST A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 16 03ST-E A 3' - 0"7' - 0"(E)(E)-(E)(E)---(E) 004 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 05 005 AA 6' - 0"7' - 0"HM PTD -HM PTD 02/A9.1-1 04/A9.1-1 01/A9.1-1 26 005A-E A 3' - 0"7' - 0"(E)(E)-(E)(E)---(E) 006-E A 3' - 6"7' - 0"(E)(E)-(E)(E)---(E) 007-E A 3' - 9"7' - 0"(E)(E)-(E)(E)---(E) 008-E A 3' - 0"7' - 0"(E)(E)-(E)(E)---(E) 010 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 09 UNDER-CUT 011 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 09 UNDER-CUT 012 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 05 013 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 05 014 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 05 015 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 05 016 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 05 017 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 05 018 A 3' - 0"7' - 0"HM PTD -HM PTD 02/A9.1-1 04/A9.1-1 01/A9.1-1 04 1HR FIRE RATING 019 A 3' - 0"7' - 0"HM PTD -HM PTD 02/A9.1-1 04/A9.1-1 01/A9.1-1 18 1HR FIRE RATING 019A A 3' - 0"7' - 0"HM PTD -HM PTD 02/A9.1-1 04/A9.1-1 01/A9.1-1 18 1HR FIRE RATING 021 A 2' - 6"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 01 022 A 2' - 6"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 01 023 A 2' - 6"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 03 UNDER-CUT 165 X 3' - 3"3' - 0"HM PTD -HM PTD ---(E)DUMBWAITER DOOR; NON FUNCTIONAL AND LOCKED ST1 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 22 1HR FIRE RATING; PHW; CR ST2 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 22 1HR FIRE RATING; PHW; CR DOOR SCHEDULE DOOR NUMBER DOOR TYPE DOOR GLAZING TYPE FRAME DETAILS REMARKSWIDTHHEIGHTMATERIALFINISHMATERIALFINISHHEADJAMBSILLHARDWARE 1STG1-E G1 3' - 9"3' - 4"(E)(E)(E)(E)(E)---34 GATE; PHW 1STG2-E G1 3' - 9"3' - 4"(E)(E)(E)(E)(E)---34 GATE; PHW 102 CC 6' - 0"7' - 0"AL CLEAR ANO DL AL ANO 06/A9.1-1 08/A9.1-1 05/A9.1-1 20 PHW; CR 102A A 3' - 6"7' - 0"HM PTD -HM PTD 02/A9.1-1 04/A9.1-1 01/A9.1-1 25 102B A 2' - 6"7' - 0"HM PTD -HM PTD 02/A9.1-1 04/A9.1-1 01/A9.1-1 02 102C CC 6' - 0"7' - 0"AL CLEAR ANO DL AL ANO 06/A9.1-1 08/A9.1-1 05/A9.1-1 20 PHW; CR 102D CC 6' - 0"7' - 0"AL CLEAR ANO DL AL ANO 06/A9.1-1 08/A9.1-1 05/A9.1-1 20 PHW; CR 103A C 3' - 0"7' - 0"AL CLEAR ANO DL AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 06 104 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 16 UNDER-CUT 105 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 16 UNDER-CUT 106 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 15 GASKETING; CR 108 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 35 CR 110 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 16 UNDER-CUT 111 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 16 UNDER-CUT 112 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 04 113 AA 5' - 0"6' - 8"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 32 114 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 36 UNDER-CUT; REMOTE CONTROLLED LOCK 115 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 36 UNDER-CUT; REMOTE CONTROLLED LOCK 123 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 11 CR 123A A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 38 123C A 3' - 0"7' - 0"HM PTD -HM PTD 02/A9.1-1 04/A9.1-1 01/A9.1-1 17 1HR FIRE RATING; MAG. HOLD OPEN 124 F 6' - 0"7' - 0"SC PTD -AL ANO 02/A9.1-2 04/A9.1-2 01/A9.1-2 27 SLIDING POCKET DOOR SCHEDULE DOOR NUMBER DOOR TYPE DOOR GLAZING TYPE FRAME DETAILS REMARKSWIDTHHEIGHTMATERIALFINISHMATERIALFINISHHEADJAMBSILLHARDWARE 2ST5-E A 3' - 0"7' - 0"(E)(E)-(E)(E)---(E) 2T1 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 09 UNDER-CUT 2T2 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 09 UNDER-CUT 2T3 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 10 CR; UNDER-CUT 200B A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 11 CR 201 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 21 CR 202 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 21 CR 211 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 07 211A C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 21 CR 211B A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 08 211C A 2' - 6"6' - 8"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 01 212 CC 6' - 0"7' - 0"AL CLEAR ANO DT AL ANO 06/A9.1-1 08/A9.1-1 05/A9.1-1 24 CR 212A C 3' - 6"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 33 CR 213 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 07 214 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 07 217-E A 3' - 0"7' - 0"(E)(E)-(E)(E)---(E) 218 A 3' - 0"7' - 0"HM PTD -HM PTD 02/A9.1-1 04/A9.1-1 01/A9.1-1 03 219 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 14 CR 220 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 16/A9.1-1&11/A9.3-1 05/A9.1-1 21 CR 221 C 3' - 0"7' - 0"AL CLEAR ANO DT AL ANO 10/A9.1-1 16/A9.1-1&11/A9.3-1 05/A9.1-1 21 CR 222 A 3' - 0"7' - 0"SC PTD -AL ANO 10/A9.1-1 12&16/A9.1-1 09/A9.1-1 12 CR; PEEP HOLE 223 C 3' - 0"7' - 0"AL CLEAR ANO DL AL ANO 10/A9.1-1 16/A9.1-1&11/A9.3-1 05/A9.1-1 06 224 C 3' - 0"7' - 0"AL CLEAR ANO DL AL ANO 10/A9.1-1 12&16/A9.1-1 05/A9.1-1 12 CR 225 C 3' - 0"7' - 0"AL CLEAR ANO DL AL ANO 10/A9.1-1 16/A9.1-1&11/A9.3-1 05/A9.1-1 06 226 C 3' - 0"7' - 0"AL CLEAR ANO DL AL ANO 10/A9.1-1 16/A9.1-1&11/A9.3-1 05/A9.1-1 06 2ND FLOOR 1ST FLOOR BASEMENT #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #003 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #78 RFI #126 RFI add 108-A door to the schedule. add rev tag- ASI#22 #176 RFI FIRST FLOOR -119' - 10 1/2" SECOND FLOOR -107' - 10 1/2" C D E F G H ROOF-86' - 4 1/2" 201 202 203 109 110 111 112 T.O.CORNICE-84' - 8" NEW DRIP CAP AT PARAPET, TYP. FIRST FLOOR-119' - 10 1/2" SECOND FLOOR-107' - 10 1/2" 12345678910 ROOF-86' - 4 1/2" 113 204 205 206 115 208207 EXTERIOR LIGHT TRASH ENCLOSURESTOREFRONT ENTRY W/FRAME PORTAL T.O.CORNICE-84' - 8" 3'-0" SINGLE LEAF HOLLOW METAL DOOR, WITH CARD READER INFILL WALL TO MATCH EXISTING NEW DRIP CAP AT PARAPET, TYP. 1 A8.5-2 TYP. 120-E 107 123B-E 103B-E 114-B ST4-E CARD READER. TYP.1 A8.6-1 DOOR ACTUATOR. PUSH BUTTON SET AND CARD READER MARBLE AT LOW WALLS TO BE REPLACED. REFER TO SHEET A8.8-5 FOR ADDITIONAL INFORMATION ON STONE REPLACEMENT 1 A5.0-6 5 A5.0-6 #022 ASI 108-A 3 A8.7-2 4 A8.7-2 3 A8.7-2 FIRST FLOOR-119' - 10 1/2" SECOND FLOOR-107' - 10 1/2" 1 2 3 4 5 6 7 8 9 10 ROOF-86' - 4 1/2" 101 102 103 104 105 106 107 T.O.CORNICE-84' - 8" NEW DRIP CAP AT PARAPET, TYP. 1 A8.5-2 TYP. 101 9" 104-B DOOR ACTUATOR. PUSH BUTTON SET AND CARD READER 108NEW STOREFRONT TO MATCH EXISTING 4 G1.2-8 1 A5.0-6 5 A5.0-6 #003 ASI (N) INFILL WALL. FINISHES TO MATCH (E) ADJACENT CUSTOM SECURITY SCREEN (N) OPENING 1 A3.6-2 2 A3.6-2 12' - 1"3' - 0"12' - 0" 6' - 1 0 " 5' - 0 " NEW DRIP CAP AT PARAPET, TYP. 5 A5.0-6 FIRST FLOOR-119' - 10 1/2" SECOND FLOOR-107' - 10 1/2" CDEFGH ROOF -86' - 4 1/2" EXTERIOR STOREFRONT DOOR AND METAL CLAD PORTAL EXTERIOR LIGHTEXTERIOR STOREFRONT DOOR T.O.CORNICE -84' - 8" NEW DRIP CAP AT PARAPET, TYP. SECURITY FENCE A2.5-9 3 1 A8.5-2 TYP. 100 118 210 211 116 117 103-I DOOR ACTUATOR. PUSH BUTTON SET AND CARD READER 209 REINSTALL (E) GATE 1/8" = 1'-0"2 WEST ELEVATION - NEW 1/8" = 1'-0"3 SOUTH ELEVATION - NEW 1/8" = 1'-0"4 NORTH ELEVATION - NEW 1/8" = 1'-0"5 PORTE-COCHERE - NEW 1/8" = 1'-0"1 EAST ELEVATION ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A3.1-1 BUILDING ELEVATIONS 1. 2. SEE A3.2-1 FOR WINDOW SCHEDULE AND REPAIRS SEE A3.3-2 FOR EXTERIOR DOOR SCHEDULE #003 ASI #003 ASI #003 ASI TYPE G TYPE H 2' - 0 " 5' - 0 " 2' - 0 " 9' - 0 " 14' - 6" 2' - 10 1/4"2' - 9"2' - 9"6' - 1 3/4" 1' - 1 1 " 5' - 2 " 1' - 1 1 " 9' - 0 " 2' - 10 1/4"2' - 11"2' - 11"2' - 11"2' - 11" 14' - 6" TYPE L 3 A8.6-1 2' - 4"2' - 3 3/4"TYPE M 1 A8.7-1 2 A8.7-1 3 A8.7-1 5' - 4 1 / 2 " 5' - 4 1 / 2 " 5' - 4 1 / 2 " 5' - 4 1 / 2 " 5' - 4 1 / 2 " 26 ' - 1 0 " 15' - 11 1/4" 5' - 3 3/4"5' - 3 3/4"5' - 3 3/4" PER SCHEDULE PE R S C H E D U L E TYPE J 1' - 1 1 " 3' - 6" TYPE K TYPE A TYPE C TYPE D TYPE E TYPE F TYPE B 10 A8.7-1 8 A8.7-1 9 A8.7-1 1 A8.7-2 2 A8.7-2 2' - 6 " 10' - 7" 5' - 8" 6' - 10" 4' - 4" 6' - 10" 4' - 4" 3' - 6" 5' - 8" 6' - 9" 4' - 2" 7' - 0" STEEL AND ALUMINIUM STOREFRONT TYPES ALUMINIUM STOREFRONT TYPES STEEL WINDOW TYPES 3' - 6" 5 A8.7-1 7 A8.7-1 5 A8.7-1 5 A8.7-1 7 A8.7-1 5 A8.7-1 7 A8.7-1 7 A8.7-1 3 A8.6-1 3 A8.6-1 3 A8.6-1 SHADE 1 SHADE 2 SHADE 1 SHADE 2 #63 RFI NOT USED ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A3.2-1 ENLARGED WINDOW ELEVATIONS (EXTERIOR) 211 E EAST 6' - 10" x 5'-8"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 210 E EAST 6' - 10" x 5'-8"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 209 E EAST 6' - 10" x 5'-8"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 208 D SOUTH 6' - 9" x 5'-8"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 207 A SOUTH 3' - 6" x 4'-4"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 206 C SOUTH 6' - 10" x 4'-4"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 205 A SOUTH 3' - 6" x 4'-4"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 204 E SOUTH 6' - 10" x 5'-8"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 203 E WEST 6' - 10" x 5'-8"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 202 E WEST 6' - 10" x 5'-8"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 201 E WEST 6' - 10" x 5'-8"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 SECOND FLOOR WINDOW SCHEDULE 118 K EAST 7'-0"X9'-0"FIXED ALUMINUM ANODIZED NO 1 N/A 3/A8.6-1 3/A8.6-1 NEW STOREFRONT SIDELIGHT AND TRANSOM. SEE A3.3-2 FOR DOOR TYPE D INFORMATION 117 J EAST 7' - 0" x 2'-0"FIXED ALUMINUM ANODIZED NO 1 N/A --3/A8.6-1 3/A8.6-1 NEW STOREFRONT TRANSOM. SEE A3.3-2 FOR DOOR TYPE DD INFORMATION 116 E EAST 6'-10"X5'-8"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 115 C SOUTH 6' - 10" x 4'-4"FIXED STEEL PAINT YES 2 MANUAL 5/A8.-7-1 7/A8.7-1 7/A8.7-1 114-B J SOUTH 6'-2"X1'-0"FIXED ALUMINUM ANODIZED NO 1 N/A 3/A8.6-1 3/A8.6-1 NEW STOREFRONT TRANSOM. SEE A3.3-2 FOR DOOR TYPE DD INFORMATION 114 B SOUTH 7' - 0" x 4'-2"FIXED STEEL PAINT NO 2 MANUAL 1/A8.7-2 2/A8.7-2 2/A8.7-2 NOT USED 113 H SOUTH 14' -6" x 9'-0"FIXED ALUMINUM ANODIZED YES 1 MOTORIZED ------STOREFRONT. SEE A3.3-2 FOR DOOR TYPE DD INFORMATION. CLEAN W/DETERGENT 112 F WEST 10'-8" X 2'-8"FIXED HOLLOW METAL PAINT YES 3 MOTORIZED 8/A8.7-1 9/A8.7-1 10/A8.7-1 CLERESTORY 111 F WEST 10'-8" X 2'-8"FIXED HOLLOW METAL PAINT YES 3 MOTORIZED 8/A8.7-1 9/A8.7-1 10/A8.7-1 CLERESTORY 110 F WEST 10'-8" X 2'-8"FIXED HOLLOW METAL PAINT YES 3 MOTORIZED 8/A8.7-1 9/A8.7-1 10/A8.7-1 CLERESTORY 109 F WEST 10'-8" X 2'-8"FIXED HOLLOW METAL PAINT YES 3 MOTORIZED 8/A8.7-1 9/A8.7-1 10/A8.7-1 CLERESTORY 108 G NORTH 14' -6" x 9'-0"FIXED ALUMINUM ANODIZED NO 1A MOTORIZED --2/A8.6-1 1/A8.6-1 NEW STOREFRONT TO MATCH EXISTING 107 M NORTH 15' -11" X 26'-10"FIXED STEEL PAINT YES 1A N/A 1/A8.7-1 2/A8.7-1 3/A8.7.1 106 M NORTH 15' -11" X 26'-10"FIXED STEEL PAINT YES 1A N/A 1/A8.7-1 2/A8.7-1 3/A8.7.1 105 M NORTH 15' -11" X 26'-10"FIXED STEEL PAINT YES 1A N/A 1/A8.7-1 2/A8.7-1 3/A8.7.1 104-B J NORTH 7'-0"X4'-0"FIXED ALUMINUM ANODIZED NO 1A N/A --3/A8.6-1 3/A8.6-1 NEW STOREFRON TRANSOM. SEE A3.3-2 FOR DOOR TYPE DD INFORMATION. VERIFY DIMENSIONS IN FIELD. 104 L NORTH 15' -11" X 26'-10"FIXED STEEL PAINT YES 1A N/A 1/A8.7-1 2/A8.7-1 3/A8.7.1 MAIN ENTRANCE WINDOW 103 M NORTH 15' -11" X 26'-10"FIXED STEEL PAINT YES 1A N/A 1/A8.7-1 2/A8.7-1 3/A8.7.1 102 M NORTH 15' -11" X 26'-10"FIXED STEEL PAINT YES 1A N/A 1/A8.7-1 2/A8.7-1 3/A8.7.1 101 M NORTH 15' -11" X 26'-10"FIXED STEEL PAINT YES 1A N/A 1/A8.7-1 2/A8.7-1 3/A8.7.1 SILL JAMB HEADNUMBERTYPELOCATIONDIMENSIONS (W X H)OPERATION MATERIAL FINISH EXISTIN G GLASS TYPE SHADE DETAILS REMARKS FIRST FLOOR WINDOW SCHEDULE 1. 2. A. B. C. D. 3. A. B. C. D. SEE SPECIFICATIONS FOR GLAZING REPLACEMENT AND WINDOW REPAIRS. REPAIRS OF STEEL STOREFRONT WINDOWS AT NORTH ELEVATION REMOVE LOOSE RUST TO SOUND RUST FREE MATERIAL WITH APPROVED METHODS. NOTIFY ARCHITECT IF SECTION LOSS OR RUST REMOVAL HAS CREATED ANY DEPRESSIONS. PREPARE, PRIME, AND PAINT. REPLACE GLAZING STOPS TO MATCH EXISTING REPAIRS OF PUNCHES STEEL WINDOWS REMOVE LOOSE RUST TO SOUND, RUST FREE MATERIAL WITH APPROVED METHODS. NOTIFY ARCHITECT IF SECTION LOSS OR RUST REMOVAL HAS CREATED ANY DEPESSIONS. PREPARE, PRIME AND PAINT. REPLACE GLAZING PUTTY TO MATCH EXISTING. GLASS TYPES 1.INSULATED - TEMPERED 1A.INSULATED - TEMPERED W/FILM ON INTERIOR SURFACE 2.LAMINATED 3.WIRE GLASS, 3/4-HR RATED #63 RFI #63 RFI #022 ASI TYPE - D TYPE - DD TYPE - A EXTERIOR HOLLOW METAL DOOR TYPE EXTERIOR STOREFRONT DOOR TYPES 10 " 3 1/2"3 1/2"3 1/2"3 1/2"3 1/2"3 1/2" 3' - 4 " PANIC HARDWARE, W.O. 2 A8.6-1 1 A8.6-1 2 A8.6-1 1 A8.6-1 1 A8.6-1 ST4-E A SOUTH YES 3'-0"7'-0"HM PTD N/A HM PTD ------H06 ADD CR 123B-E A SOUTH YES 3'-6"7'-0"HM PTD N/A HM PTD ------H01 ADD CR 120-E DD SOUTH YES 6'-0"7'-0"AL ANO DT AL ANO ------H04 EXISTING DOOR TO REMAIN. CLEAN W/DETERGENT. PHW. INSTALL ACTUATOR 108-A A SOUTH NO 3'-0"7'-0"HM PTD N/A HM PTD --3 & 4/A8.7-2 3/A8.7-2 H07 ADD CR 107 DD SOUTH NO 6'-0"7'-0"AL ANO DT AL ANO 1/A8.6-1 2/A8.6-1 2/A8.6-1 SIM H03 SOUTH PORTAL ENTRANCE. PHW, INSYALL ACTUATOR AND CARD READER. SEE A3.2-1 FOR STOREFRONT ADDITIONAL INFORMATION. 103B-E A SOUTH YES 3'-0"7'-0"HM PTD N/A HM PTD ------H01 ADD CR 103-I DD EAST NO 6'-0"7'-0"AL ANO DT AL ANO 1/A8.6-1 2/A8.6-1 2/A8.6-1 SIM H02 PHW, INSTALL ACTUATOR AND CARD READER. SEE A3.2-1 FOR STOREFRONT ADDITIONAL INFORMATION. 101 DD NORTH NO 7'-0"8'-0"AL ANO DT AL ANO 1/A8.6-1 2/A8.6-1 2/A8.6-1 SIM H02 MAIN ENTRANCE. PHW, INSTALL ACTUATOR ON EXTERIOR AND INTERIOR, ADD CARD READER. SEE A3.2-1 FOR STOREFRONT ADDITIONAL INFORMATION. 100 D EAST NO 3'-2"7'-0"AL ANO DT AL ANO 1/A8.6-1 2/A8.6-1 2/A8.6-1 SIM H05 PHW, W/SIDELITE. INSTALL ACTUATOR. SEE A3.2-1 FOR STOREFRONT ADDITIONAL INFORMATION. ADD CR WIDTH HEIGHT MAT.FINISH THRESHOLD JAMB HEADNUMBERTYPELOCATIONEXISTING DIMENSIONS MAT.FINISH Glass Type FRAME DETAILS HW SET #REMARKS EXTERIOR DOOR SCHEDULE ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A3.3-2 EXTERIOR DOOR SCHEDULE 1. 2. 3. SEE SPECIFICATIONS FOR GLAZING REPLACEMENT AND REPAIRS. SEE A2.6-0 FOR DOOR SCHEDULE NOTES SEE A3.2-1 FOR ADDITIONAL STOREFRONT WINDOWS INFROMATION GLASS TYPES CL -1/2" LAMINATED INSULATED GLAZING UNIT D -1/4" FLOAT GLASS DL -1" LAMINATED INSULATED GLAZING UNIT DT -1/4" TEMPERED CLEAR #003 ASI #003 ASI #022 ASI FRP- FIBERGLASS REINFORCED PLASTIC PANEL P-1 - PAINT COLOR 1 P-2 - PAINT COLOR 2 P-3 - PAINT COLOR 3 P-4 - PAINT COLOR 4 P-5 - PAINT COLOR 5 P-6 - PAINT COLOR 6 PT-2 - PORCELAIN TILE AWP- ACOUSTIC WALL PANEL TB- TACKBOARD MB- MARKERBOARDS ST-1 - STAINLESS STEEL (ELEVATOR) STANDARD FRP DEW325 VANILLA SHAKE DE5765 SURFSIDE DET 498 CORNSILK YELLOW DE5881 NEWBURY PORT DE5763 SPARKLING RIVIER DE290 HIGHLANDER (GALAX-Z) PORTFOLIO SEE SPECS SEE SPECS MAGNETIC GLASS MAKER BOARD SEE SPECS WALL MATERIALS SCHEDULE TYPE MANUFACTURE MODEL DESCRIPTION COMMENTS MARLITE DUNN EDWARDS DUNN EDWARDS DUNN EDWARDS DUNN EDWARDS DUNN EDWARDS DUNN EDWARDS DALTILE CERTAINTEED CLARUS FLOAT SEE SPECS SMOOTH SURFACE - S 100 S/2/S WHITE TO MATCH ARCHITECT'S SAMPLE TO MATCH ARCHITECT'S SAMPLE TO MATCH ARCHITECT'S SAMPLE TO MATCH ARCHITECT'S SAMPLE TO MATCH ARCHITECT'S SAMPLE TO MATCH ARCHITECT'S SAMPLE SIZE: 12 X 24; DOVE GREY SEE SPECS SEE SPECS SMOOOTH SURFACE -S 100 S/2/S WHITE SEE SPECS SEE SPEC. SEE SPEC. ROOM 001, 012, 013, 014, 015, 016, 017 ACCENT COLOR ROOM 211, 212 ACCENT COLOR ROOM 221, 220, 202 200A, 201, 211A ACCENT COLOR ROOM 023, 024, 025, 116, 213 ACCENT COLOR ROOM 214 GREEN SCREEN/ ACCENT COLOR SEE SPEC. SEE A4.& A5.SERIES FOR COLOR & LOCATION SEE SPEC. SEE SPEC. 010 - E 011 - E 010A - E 021 - E 022 - E 023 - E 005A - E DOOR FINSH SCHEDULE DOOR NUMBER DOOR FINISH DESCRIPTION P-1 P-1 P-1 P-1 P-1 P-1 P-1 Dunn Edwards DEW325 Vanilla Shake Dunn Edwards DEW325 Vanilla Shake Dunn Edwards DEW325 Vanilla Shake Dunn Edwards DEW325 Vanilla Shake Dunn Edwards DEW325 Vanilla Shake Dunn Edwards DEW325 Vanilla Shake Dunn Edwards DEW325 Vanilla Shake COUNTER TOP CASEWORK PLASTIC LAMINATE COUNTERTOP AND CASEWORK PLASTIC LAMINATE SCHEDULE TYPE MANUFACTURE MODEL / COLOR CAMBRIA WILSONART COLTON-- FONTHILL PEAR 10745-60/ MATTE FINSH ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A4.0-1 FINISH SCHEDULE & NOTES ROOM FINISH SCHEDULE ROOM NO.ROOM NAME WALL FINISH FLOOR FINISH BASE NOTESNORTHEASTSOUTHWESTNORTHEASTSOUTHWEST 001 STAFF OFFICE P-1 P-1 P-1, P-2 P-1 C-4 R-1 R-1 R-1 R-1 002 ARCHIVES P-1 P-1 P-1 P-1 R-2 R-1 R-1 R-1 R-1 2S3 STAIR 3 P-1 P-1 P-1 P-1 CO-1 R-1 R-1 R-1 R-1 2T1 ALL GENDER RESTROOM PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-1 T-1 T-1 T-1 T-1 2T2 ALL GENDER RESTROOM PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-1 T-1 T-1 T-1 T-1 2T3 STAFF RESTROOM PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-1 T-1 T-1 T-1 T-1 003 MECH EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 004 STAFF BREAK ROOM P-1 P-1 P-1 P-1 R-1 R-1 R-1 R-1 R-1 005 STORAGE P-1 P-1 P-1 P-1 CO-1 R-1 R-1 R-1 R-1 005A (E) ELEV. CONTROL RM.EXITING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 005B VESTIBULE 006 FIRE AL.RM EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 007 ELEVATOR-ABAN.EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 008 MECH-ABAN.EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 009 ELEVATOR LOBBY P-1 P-1 P-1 P-1 CO-1 R-1 R-1 R-1 R-1 010 ALL GENDER RESTROOM PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-1 T-1 T-1 T-1 T-1 011 ALL GENDER RESTROOM PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-1 T-1 T-1 T-1 T-1 012 OFFICE P-1 P-1 P-2 P-1 C-4 R-1 R-1 R-1 R-1 013 OFFICE P-1 P-1 P-2 P-1 C-4 R-1 R-1 R-1 R-1 014 STAFF MEETING ROOM P-1 P-1 P-2 P-1 C-4 R-1 R-1 R-1 R-1 015 OFFICE P-1 P-1 P-2 P-1 C-4 R-1 R-1 R-1 R-1 016 OFFICE P-1 P-1 P-2 P-1 C4 R-1 R-1 R-1 R-1 017 OFFICE P-1 P-1 P-2 P-1 C-4 R-1 R-1 R-1 R-1 018 ELEV. CONTROL P-1 P-1 P-1 P-1 EXISTING R-1 R-1 R-1 R-1 019 ELECTRICAL P-1 P-1 P-1 P-1 EXISTING R-1 R-1 R-1 R-1 021 STORAGE P-1 P-1 P-1 P-1 C-4 R-1 R-1 R-1 R-1 022 STORAGE P-1 P-1 P-1 P-1 C-4 R-1 R-1 R-1 R-1 023 JANITOR.FRP FRP FRP FRP CO-1 NO BASE NO BASE NO BASE NO BASE 100 VESTIBULE P-4 P-1 P-1 P-1 C-5 R-1 R-1 R-1 R-1 101 GREAT READING ROOM P-1 P-1 P-1 P-1 C-5, MT-1A, MT 1-B R-1 R-1 R-1 R-1 102 MEETING/COMMUNITY ROOM P-1 P-1 WP P-1 C-5 R-1 R-1 R-1 R-1 102A STORAGE P-1 P-1 P-1 P-1 C-5 R-1 R-1 R-1 R-1 102B AV CLOSET P-1 P-1 P-1 P-1 C-5 R-1 R-1 R-1 R-1 103 BOOKMOBILE ROOM P1 P1 P1 P1 C-4, R-1 R-1 R-1 R-1 R-1 103A OFFICE P-1 P-1 P-1 P-1 C-4 R-1 R-1 R-1 R-1 104 STAFF-WOMEN RESTROOM PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-1 T-1 T-1 T-1 T-1 105 STAFF MEN RESTROOM PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-1 T-1 T-1 T-1 T-1 106 I.T.P-1 P-1 P-1 P-1 CO-1 R-1 R-1 R-1 R-1 107 VESTIBULE P-1 P-1 P-1 P-1 C5 R-1 R-1 R-1 R-1 108 STORAGE P-1 P-1 P-1 P-1 CO-1 R-1 R-1 R-1 R-1 109 BOOKSTORE P-1 P-1 P-1 P-1 C-1 R-1 R-1 R-1 R-1 110 MEN RR PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-1 T-1 T-1 T-1 T-1 111 WOMEN RR PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 PT-1 T-1 T-1 T-1 T-1 112 JAN. RM FRP FRP FRP FRP EXISTING NO BASE NO BASE NO BASE NO BASE 113 MECH.P-1 P-1 P-1 P-1 CO-1 R-1 R-1 R-1 R-1 114 ALL GENDER RESTROOM TW-1, P-1 TW-1, P-1 TW-1, P-1 TW-1, P-1 PT-1 T-1 T-1 T-1 T-1 115 ALL GENDER RESTROOM TW-1, P-1 TW-1, P-1 TW-1, P-1 TW-1, P-1 PT-1 T-1 T-1 T-1 T-1 116 NURSING/SENSORY P-1 P-1 P-5 P-1 C-3C R-1 R-1 R-1 R-1 117 YOUTH STACKS N/A P-1 P-1 N/A C-2C R-1 R-1 R-1 R-1 118 YOUTH STACKS N/A N/A P-7 P-7 C-1 N/A N/A R-1 N/A 119 ADULT STACKS N/A P-7 P-7 N/A C-1 N/A R-1 R-1 N/A 120 TODDLERS AND INFANTS P-1 P-1 P-1 P-1 C-2A, C-2B R-1 R-1 R-1 R-1 121 FAMILY ZONE P-1 P-1 P-1 P-1 C-3B, C-3C R-1 R-1 R-1 R-1 122 FIREPLACE ROOM P-1 P-1 P-1 P-1 C-1 R-1 R-1 R-1 R-1 123 SORTING P1 P1 P1 P1 C-4, R-1 R-1 R-1 R-1 R-1 124 STORAGE P-1 P-1 P-1 P-1 C3-A R-1 R-1 R-1 R-1 200 ADULT STACKS N/A P-1 P-1 P-1 C-1 R-1 R-1 R-1 R-1 200A VESTIBULE SEATING N/A P-1 P-4 P-1 C-1 R-1 R-1 R-1 R-1 200B STORAGE P-1 P-1 P-1 P-1 CO-1 R-1 R-1 R-1 R-1 201 STUDY P-1 P-1 P-4 P-1 C-5 R-1 R-1 R-1 R-1 202 STUDY P-1 P-1 P-4 P-1 C-5 R-1 R-1 R-1 R-1 211 YOUNG ADULT P-1 P-1 P-3 P-1 C-6, C-6A R-1 R-1 R-1 R-1 211A YA STUDY BOOTH P-4 P-1 P-1 P-1 C-5 R-1 R-1 R-1 R-1 212 MAKER SPACE P-1 P-1 P-1 P-1 R-2 R-1 R-1 R-1 R-1 213 VIDEO EDITING BOOTH AWP-1, P-5 AWP-1 AWP-1 N/A C-5 R-1 R-1 R-1 R-1 214 VIDEO RECORDING BOOTH AWP-1,P-6 N/A AWP-1 AWP-1 C-5 R-1 R-1 R-1 R-1 216 MAKER STORAGE P-1 P-1 P-1 P-1 R-2 R-1 R-1 R-1 R-1 217 JAN.RM FRP FRP FRP FRP EXISTING NO BASE NO BASE NO BASE NO BASE 218 ELEC. RM.P-1 P-1 P-1 P-1 CO-1 R-1 R-1 R-1 219 ELEVATOR N/A N/A N/A N/A CO-1 R-1 R-1 R-1 R-1 220 STUDY P-1 P-1 P-4 P-1 C-5 R-1 R-1 R-1 R-1 221 STAFF MEETING ROOM P-1 P-1 P-4 P-1 C-5 R-1 R-1 R-1 R-1 222 HISTORY P-1 P-1 P-1 P-1 C-5 R-1 R-1 R-1 R-1 223 OFFICE P-1 P-1 P-1 P-1 C-4 R-1 R-1 R-1 R-1 224 STAFF OFFICE P-1 P-1 P-1 P-1 C-4 R-1 R-1 R-1 R-1 225 OFFICE P-1 P-1 P-1 P-1 C-4 R-1 R-1 R-1 R-1 226 OFFICE P-1 P-1 P-1 P-1 C-4 R-1 R-1 R-1 R-1 ST-1 STAIR #1 P-1 P-1 P-1 P-1 RF-1 R-1 R-1 R-1 R-1 R-1 ON LANDINGS; VERIFIED IN FIELD; CUT TO FIT ST-2 STAIR #2 P-1 P-1 P-1 P-1 RF-1 R-1 R-1 R-1 R-1 R-1 ON LANDINGS; VERIFIED IN FIELD; CUT TO FIT ST-3 STAIR #3 P-1 P-1 P-1 P-1 RF-1 R-1 R-1 R-1 R-1 R-1 ON LANDINGS; VERIFIED IN FIELD; CUT TO FIT FLOOR MATERIALS SCHEDULE TYPE MANUFACTURE MODEL DESCRIPTION C-1 CARPET TILE INTERFACE DRIFTWOOD -104860 - CHESTNUT 25 cm x 1m INSTALLED ASHLAR C-2A CARPET TILE INTERFACE MOSS COLORLINE - 105563 ONYX/ MOSS 50cm INSTALLED NON DIREECTIONAL C-2B CARPET TILE INTERFACE MOSS IN STONE - 105567 ONYX EDGE 50cm INSTALLED NON DIRECTIONAL C-2C CARPET TILE INTERFACE SETT IN STONE - 105571 ONYX 50cm INSTALLED NON DIRCTIONAL C-3A CARPET TILE INTERFACE B603 - 102922 PACIFIC 50cm INSTALLED NON DIRCTIONAL C-3B CARPET TILE INTERFACE B602 - 102914 PACIFIC 50cm INSTALLED NPATTERN BY TILE C-3C CARPET TILE INTERFACE B601 - 102906 PACIFIC 50cm INSTALLED NON DIRCTIONAL C-4 CARPET TILE INTERFACE SHIVER ME TIMBERS - 103923 CYPRUS 25cm x 1m INSTALLED ASHLAR C-5 CARPET TILE INTERFACE DRIFTWOOD - 104861 ELM 25 cm x 1m INSTALLED ASHLAR C-6 CARPET TILE INTERFACE DRIFTWOOD -104850 ALDER 25 cm x 1m INSTALLED ASHLAR C-6A CARPET TILE INTERFACE DRIFTWOOD -105269 MARIGOLD 25 cm x 1m INSTALLED ASHLAR C-9 CARPET TILE PATCRAFT ARTEFACT - UNDERLING LAYER STAGGER INSTALLATION CO-1 SEALED CONCRETE MASTERKURE HD300WB SEE SPEC. MT-1A MARBLE TILE MARBLE MODERN NOCE TRAVERTINE - CROSS - CUT, 12" X 12" MATCH ARCHITECT'S SAMPLE FOR COLOR MT-1B MARBLE TILE MARBLE MODERN NOCE TRAVERTINE - CROSS - CUT, 12" X 12" MATCH ARCHITECT'S SAMPLE FOR COLOR PT-1 PORCELAN TILE DALTILE PORTFOLIO SIZE: 12 x 24; NOCE; SEE ARCHITEC'S SAMPLE R-1 RESILIENT FLOOR MARMOLEUM - FORBO PIANO - 3601 WARM GREY MATCH ARCHITECT'S SAMPLE R-2 RESILIENT FLOOR MARMOLEUM - FORBO PIANO - 3642 PERIWINKLE MATCH ARCHITECT'S SAMPLE RF-1 RUBBER STAIR TREAD ROPPE CORPORATION RAISED SQUARE RUBBER STAIR TREAD; COLOR: 670 ASPHALT; CONTRASTING STRIPT COLOR: 100 BLACK 48" L; V.I.F; CUT TO FIT; #94 SQUARE NOSE FOR STAIR #1, #2 & #3 WALL BASE SCHEDULE TYPE MANUFACTURE MODEL DESCRIPTION COMMENTS R-1 RESILIENT BASE FORBO MARMOLEUM SAMPLE TO BE SELECTED FROM FULL RANGE OF MANUFACTURER'S COLORS T-1 PORCELAIN TILE BASE DALTILE PORTFOLIO PORCELAIN TILE CONCAVE METAL TRIM #007 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI #016 ASI #016 ASI #016.1 ASI #016.1 ASI #016.1 ASI #016.1 ASI FE C FE C FE C FE C FE C DW FE C 12345678910 C D E F G H WALLS BASE FLOOR N E S W N E S W STAFF OFFICE001 P-1 R-1 C-4 P-1 P-1, P-2 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W ARCHIVES002 P-1 R-1 R-2 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W MECH-ABAN.008 EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING ELEVATOR-ABAN. 007 WALLS BASE FLOOR N E S W N E S W FIRE AL.RM006 EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING WALLS BASE FLOOR N E S W N E S W MECH003 EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING WALLS BASE FLOOR N E S W N E S W ALL GENDER RESTROOM010 PT-2, P-1 T-1 PT-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 T-1 T-1 T-1 WALLS BASE FLOOR N E S W N E S W OFFICE012 P-1 R-1 C-4 P-1 P-2 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W OFFICE013 P-1 R-1 C-4 P-1 P-2 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STAFF MEETING ROOM014 P-1 R-1 C-4 P-1 P-2 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W OFFICE015 P-1 R-1 C-4 P-1 P-2 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W ELEV. CONTROL018 P-1 R-1 EXISTING P-1 P-1 P-1 R-1 R-1 R-1 03ST-E 019 D24 B24aB24aC24aC24aC24aC24aB24a (E) ELEV. (N) PASSENGER ELEV. WALLS BASE FLOOR N E S W N E S W OFFICE017 P-1 R-1 C-4 P-1 P-2 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STAFF BREAK ROOM004 P-1 R-1 R-1 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W (E) ELEV. CONTROL RM.005A EXITING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING WALLS BASE FLOOR N E S W N E S W OFFICE016 P-1 R-1 C4 P-1 P-2 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W ELECTRICAL019 P-1 R-1 EXISTING P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STORAGE005 P-1 R-1 CO-1 P-1 P-1 P-1 R-1 R-1 R-1 P-2P-2P-2P-2P-2P-2 P-2 P-2 WALLS BASE FLOOR N E S W N E S W JANITOR.023 FRP NO BASE CO-1 FRP FRP FRP NO BASE NO BASE NO BASE WALLS BASE FLOOR N E S W N E S W ELEVATOR LOBBY009 P-1 R-1 CO-1 P-1 P-1 P-1 R-1 R-1 R-1 #41 RFI #41 RFI WALLS BASE FLOOR N E S W N E S W STORAGE022 P-1 R-1 C-4 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W ALL GENDER RESTROOM011 PT-2, P-1 T-1 PT-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 T-1 T-1 T-1 #020 ASI #020 ASI #019 ASI #019 ASI #019 ASI #016 ASI #016 ASI #016 ASI #016 ASI INDICATES AREA OF SLAB ON GRADE DEMO AND REPLACED WITH CO-1 AS REQUIRED BY PIT WALL SHORING REQUIREMENTS. #41.1 RFI #41.1 RFI#41.1 RFI WALLS BASE FLOOR N E S W N E S W STAIRST-3 P-1 R-1 RF-1 P-1 P-1 P-1 R-1 R-1 R-1 #016.1 ASI WALLS BASE FLOOR N E S W N E S W STAIRST-1 P-1 R-1 RF-1 P-1 P-1 P-1 R-1 R-1 R-1 #016.1 ASI WALLS BASE FLOOR N E S W N E S W STAIRST-2 P-1 R-1 RF-1 P-1 P-1 P-1 R-1 R-1 R-1 #016.1 ASI WALLS BASE FLOOR N E S W N E S W STORAGE021 P-1 R-1 C-4 P-1 P-1 P-1 R-1 R-1 R-1 #016.1 ASI INTERIOR FLOOR FINISH LEGEND C-5: CARPET TILE C-2A: CARPET TILE CO-1: SEALED CONCRETE R-1: RESILIENT FLOOR MT-1A: NEW TRAVERTINE FLOOR TILE LIGHT PT-1: PORCELAIN TILE C-1: CARPET TILE C-2C: CARPET TILE C-3A: CARPET TILE C-4: CARPET TILE C-2B: CARPET TILE C-3B: CARPET TILE C-3C CARPET TILE C-6: CARPET TILE C-6A: CARPET TILE MT-1B: NEW TRAVERTINE FLOOR TILE DARK R-2: RESILIENT FLOOR #016 ASI RF-1: RUBBER FLOOR FOR STAIRS #016.1 ASI INTERIOR WALL FINISH LEGEND AWP-1:TACKABLE ACOUSTIC WALL PANEL FRP:FIBER REINFORCED PLASTIC PANEL MB:MARKERBOARD P-0: PTD. GYP BOARD CEILING/SOFFIT COLOR, THE SAME PAINT AS P-1 TYPICAL U.O.N. P-1: WALL COLOR, TYPICAL U.O.N. P-2: BASEMENT OFFICE ACCENT COLOR P-3:YOUTH/ MAKER RM ACCENT COLOR P-4:HALLWAY/ STUDY ROOM ACCENT COLOR P-5:ROOM ACCENT COLOR P-6: VIDEO RECORDING ROOM GREEN WALL COLOR TW-1:PORCELAIN TILE 4' HEIGHT TYP. (SEE A5.0-0 FOR ADDITIONAL INFORMATION) WP:WOOD VENEER PANEL WG:CUSTOM ACOUSTIC WOOD GRILLE INTERIOR BASE FINISH LEGEND R-1: RUBBER BASE T-1: PORCELAIN TILE BASE 1.SEE A4.0-1 FOR FINISH LEGEND SCHEDULE AND NOTES. SHEET NOTES: ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A4.1-1 FINISH FLOOR PLAN - BASEMENT 1/8" = 1'-0"1 NP00 - FINISHING PLAN - BASEMENT FEC FE C 12345678910 C D E F G H WALLS BASE FLOOR N E S W N E S W GREAT READING ROOM101 P-1 R-1 C-5, MT-1A, MT 1-B P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W ADULT STACKS119 N/A N/A C-1 P-7 P-7 N/A R-1 R-1 N/A WALLS BASE FLOOR N E S W N E S W YOUTH STACKS118 N/A N/A C-1 N/A P-7 P-7 R-1 N/A N/A WALLS BASE FLOOR N E S W N E S W YOUTH STACKS117 N/A R-1 C-2C P-1 P-1 N/A R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STORAGE108 P-1 R-1 CO-1 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W MEN RR110 PT-2, P-1 T-1 PT-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 T-1 T-1 T-1 WALLS BASE FLOOR N E S W N E S W WOMEN RR111 PT-2, P-1 T-1 PT-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 T-1 T-1 T-1 WALLS BASE FLOOR N E S W N E S W ALL GENDER RESTROOM115 TW-1, P-1 T-1 PT-1 TW-1, P-1 TW-1, P-1 TW-1, P-1 T-1 T-1 T-1 WALLS BASE FLOOR N E S W N E S W ALL GENDER RESTROOM114 TW-1, P-1 T-1 PT-1 TW-1, P-1 TW-1, P-1 TW-1, P-1 T-1 T-1 T-1 WALLS BASE FLOOR N E S W N E S W MECH.113 P-1 R-1 CO-1 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W BOOKMOBILE ROOM103 P1 R-1 C-4, R-1 P1 P1 P1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STAFF-WOMEN RESTROOM104 PT-2, P-1 T-1 PT-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 T-1 T-1 T-1 WALLS BASE FLOOR N E S W N E S W STAFF MEN RESTROOM105 PT-2, P-1 T-1 PT-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 T-1 T-1 T-1 WALLS BASE FLOOR N E S W N E S W I.T.106 P-1 R-1 CO-1 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W BOOKSTORE109 P-1 R-1 C-1 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W SORTING123 P1 R-1 C-4, R-1 P1 P1 P1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W FAMILY ZONE121 P-1 R-1 C-3B, C-3C P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W NURSING/SENSORY116 P-1 R-1 C-3C P-1 P-5 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STORAGE124 P-1 R-1 C3-A P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W OFFICE103A P-1 R-1 C-4 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W VESTIBULE107 P-1 R-1 C5 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W MEETING/COMMUNITY ROOM102 P-1 R-1 C-5 P-1 WP P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W VESTIBULE100 P-4 R-1 C-5 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W TODDLERS AND INFANTS120 P-1 R-1 C-2A, C-2B P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W ELEVATOR219 N/A R-1 CO-1 N/A N/A N/A R-1 R-1 R-1 P-4 P-5 WALLS BASE FLOOR N E S W N E S W JAN. RM112 FRP NO BASE EXISTING FRP FRP FRP NO BASE NO BASE NO BASE ENTRANCE FLOOR MAT MIN 10' L X 6' W ENTRANCE FLOOR MAT MIN 7' W X 6' L 10' - 0" 6' - 0 " 7' - 0" 6' - 0 " #020 ASI #020 ASI #020 ASI #020 ASI #020 ASI NEW TRAVERTINE TILE MT-1A & MT-1B; SEE 12/ A9.2-1 FOR FLOORING STONE TILE TRANSITION #020 ASI #020 ASI #020 ASI #020 ASI #016 ASI #016 ASI #016 ASI #016 ASI WALLS BASE FLOOR N E S W N E S W STAIR #2ST-2 P-1 R-1 RF-1 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STAIR #1ST-1 P-1 R-1 RF-1 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W AV CLOSET102B P-1 R-1 C-5 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STORAGE102A P-1 R-1 C-5 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STAIR #3ST-3 P-1 R-1 RF-1 P-1 P-1 P-1 R-1 R-1 R-1 #016.1 ASI #016.1 ASI #016.1 ASI #016.1 ASI #016.1 ASI #016.1 ASI #016.1 ASI #016.1 ASI WALLS BASE FLOOR N E S W N E S W FIREPLACE ROOM122 P-1 R-1 C-1 P-1 P-1 P-1 R-1 R-1 R-1 INTERIOR FLOOR FINISH LEGEND C-5: CARPET TILE C-2A: CARPET TILE CO-1: SEALED CONCRETE R-1: RESILIENT FLOOR MT-1A: NEW TRAVERTINE FLOOR TILE LIGHT PT-1: PORCELAIN TILE C-1: CARPET TILE C-2C: CARPET TILE C-3A: CARPET TILE C-4: CARPET TILE C-2B: CARPET TILE C-3B: CARPET TILE C-3C CARPET TILE C-6: CARPET TILE C-6A: CARPET TILE MT-1B: NEW TRAVERTINE FLOOR TILE DARK R-2: RESILIENT FLOOR #016 ASI RF-1: RUBBER FLOOR FOR STAIRS #016.1 ASI INTERIOR WALL FINISH LEGEND AWP-1:TACKABLE ACOUSTIC WALL PANEL FRP:FIBER REINFORCED PLASTIC PANEL MB:MARKERBOARD P-0: PTD. GYP BOARD CEILING/SOFFIT COLOR, THE SAME PAINT AS P-1 TYPICAL U.O.N. P-1: WALL COLOR, TYPICAL U.O.N. P-2: BASEMENT OFFICE ACCENT COLOR P-3:YOUTH/ MAKER RM ACCENT COLOR P-4:HALLWAY/ STUDY ROOM ACCENT COLOR P-5:ROOM ACCENT COLOR P-6: VIDEO RECORDING ROOM GREEN WALL COLOR TW-1:PORCELAIN TILE 4' HEIGHT TYP. (SEE A5.0-0 FOR ADDITIONAL INFORMATION) WP:WOOD VENEER PANEL WG:CUSTOM ACOUSTIC WOOD GRILLE INTERIOR BASE FINISH LEGEND R-1: RUBBER BASE T-1: PORCELAIN TILE BASE 1.SEE A4.0-1 FOR FINISH LEGEND SCHEDULE AND NOTES. SHEET NOTES: ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A4.1-2 FINISH FLOOR PLAN- 1ST FLOOR 1/8" = 1'-0"1 NP01- FINISH FLOOR PLAN- FIRST FLOOR MT-1 #020 ASI FE C FE C FEC 12345678910 C D E F G H WALLS BASE FLOOR N E S W N E S W HISTORY222 P-1 R-1 C-5 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W YOUNG ADULT211 P-1 R-1 C-6, C-6A P-1 P-3 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STUDY202 P-1 R-1 C-5 P-1 P-4 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W ALL GENDER RESTROOM2T1 PT-2, P-1 T-1 PT-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 T-1 T-1 T-1 WALLS BASE FLOOR N E S W N E S W ALL GENDER RESTROOM2T2 PT-2, P-1 T-1 PT-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 T-1 T-1 T-1 WALLS BASE FLOOR N E S W N E S W STAFF RESTROOM2T3 PT-2, P-1 T-1 PT-1 PT-2, P-1 PT-2, P-1 PT-2, P-1 T-1 T-1 T-1 WALLS BASE FLOOR N E S W N E S W STUDY220 P-1 R-1 C-5 P-1 P-4 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STAFF MEETING ROOM221 P-1 R-1 C-5 P-1 P-4 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W ADULT STACKS200 N/A R-1 C-1 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W VESTIBULE SEATING200A N/A R-1 C-1 P-1 P-4 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STUDY201 P-1 R-1 C-5 P-1 P-4 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W JAN.RM217 FRP NO BASE EXISTING FRP FRP FRP NO BASE NO BASE NO BASE WALLS BASE FLOOR N E S W N E S W STAIR 32S3 P-1 R-1 CO-1 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W MAKER STORAGE216 P-1 R-1 R-2 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STORAGE200B P-1 R-1 CO-1 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W OFFICE226 P-1 R-1 C-4 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W OFFICE223 P-1 R-1 C-4 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W YA STUDY BOOTH211A P-4 R-1 C-5 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STAFF OFFICE224 P-1 R-1 C-4 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W STAIR 32S3 P-1 R-1 CO-1 P-1 P-1 P-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W ELEC. RM.218 P-1 R-1 CO-1 P-1 P-1 P-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W VIDEO RECORDING BOOTH214 AWP-1,P-6 R-1 C-5 N/A AWP-1 AWP-1 R-1 R-1 R-1 WALLS BASE FLOOR N E S W N E S W VIDEO EDITING BOOTH213 AWP-1, P-5 R-1 C-5 AWP-1 AWP-1 N/A R-1 R-1 R-1 P-4P-4 P-4 P-4 P-3 P-6 P-5 P-4 #020 ASI #020 ASI#020 ASI #020 ASI #020 ASI #020 ASI P-4 #020 ASI #020 ASI C- 6 A #020 ASI WALLS BASE FLOOR N E S W N E S W MAKER SPACE212 P-1 R-1 R-2 P-1 P-1 P-1 R-1 R-1 R-1 #016 ASI #016 ASI #016 ASI WALLS BASE FLOOR N E S W N E S W OFFICE225 P-1 R-1 C-4 P-1 P-1 P-1 R-1 R-1 R-1 #016.1 ASI #016.1 ASI #016.1 ASI #016.1 ASI INTERIOR FLOOR FINISH LEGEND C-5: CARPET TILE C-2A: CARPET TILE CO-1: SEALED CONCRETE R-1: RESILIENT FLOOR MT-1A: NEW TRAVERTINE FLOOR TILE LIGHT PT-1: PORCELAIN TILE C-1: CARPET TILE C-2C: CARPET TILE C-3A: CARPET TILE C-4: CARPET TILE C-2B: CARPET TILE C-3B: CARPET TILE C-3C CARPET TILE C-6: CARPET TILE C-6A: CARPET TILE MT-1B: NEW TRAVERTINE FLOOR TILE DARK R-2: RESILIENT FLOOR #016 ASI RF-1: RUBBER FLOOR FOR STAIRS #016.1 ASI INTERIOR WALL FINISH LEGEND AWP-1:TACKABLE ACOUSTIC WALL PANEL FRP:FIBER REINFORCED PLASTIC PANEL MB:MARKERBOARD P-0: PTD. GYP BOARD CEILING/SOFFIT COLOR, THE SAME PAINT AS P-1 TYPICAL U.O.N. P-1: WALL COLOR, TYPICAL U.O.N. P-2: BASEMENT OFFICE ACCENT COLOR P-3:YOUTH/ MAKER RM ACCENT COLOR P-4:HALLWAY/ STUDY ROOM ACCENT COLOR P-5:ROOM ACCENT COLOR P-6: VIDEO RECORDING ROOM GREEN WALL COLOR TW-1:PORCELAIN TILE 4' HEIGHT TYP. (SEE A5.0-0 FOR ADDITIONAL INFORMATION) WP:WOOD VENEER PANEL WG:CUSTOM ACOUSTIC WOOD GRILLE INTERIOR BASE FINISH LEGEND R-1: RUBBER BASE T-1: PORCELAIN TILE BASE 1.SEE A4.0-1 FOR FINISH LEGEND SCHEDULE AND NOTES. SHEET NOTES: ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A4.1-3 FINISH FLOOR PLAN - 2ND FLOOR 1/8" = 1'-0"1 NP02 - FINISH FLOOR PLAN - SECOND FLOOR FE C FE C FE C FE C FE C FE C 12345678910 C D E F G H STAFF OFFICE 001 MECH 003 ALL GENDER RESTROOM 010 STAFF MEETING ROOM 014 OFFICE 013 OFFICE 012 ARCHIVES 002 ELEV. CONTROL 018 FIRE AL.RM 006 ELEVATOR-ABAN. 007 MECH-ABAN. 008 OPEN TO STRUCTURE OPEN TO STRUCTURE OPEN TO STRUCTURE OPEN TO STRUCTURE +7'-10" +7'-10" (E) ELEV. CONTROL RM. 005A STAFF BREAK ROOM 004 +7'-10" +7'-10"+7'-10"+7'-10"+7'-10" OPEN TO STRUCTURE +9'-8 1/4" +9'-8 1/4" +9'-8 1/4" +9'-8 1/4" +9'-8 1/4" OFFICE 015 OFFICE 016 OFFICE 017 STORAGE 005 SMOKE CONTAINMENT SYSTEM +7'-8" +8'-0" #002 ASI #002 ASI #002 ASI #002 ASI +8'-0" +8'-0" +7'-10"+7'-10" +7'-10" +6'-2"+6'-2"+6'-2"+6'-2"+6'-2"+6'-2" #020 ASI #020 ASI #020 ASI #020 ASI #002 ASI #020 ASI #020 ASI #019 ASI #019 ASI #020 ASI ALL GENDER RESTROOM 011 9" 2' - 0 " +7'-6" 7' - 5" 7' - 3" 9' - 0 " EXISTING CABLE TRAY SEE TN.6.1-0 EXISTING CABLE TRAY SEE TN.6.1-0 9 A9.4-1 9 A9.4-1 0' - 2"0' - 2" 0' - 2"0' - 2" 6 A9.4-1 6 A9.4-1 #159.1 RFI REFLECTED CEILING PLAN LEGEND G-1: GYPSUM BOARD CEILING PTD. ACT-2: 2'X4' ACOUSTIC CEILING TILE ACT-1: 1'X1' ACOUSTIC CEILING TILE W-1: CUSTOM WOOD GRILLE WITH ACOUSTIC BACKING OPEN TO STRUCTURE ABOVE C -1: CEMENT PLASTER (E) CEILING TO REMAIN #002 ASI 1. 2. LIGHT FIXUTRE AND LIGHTING SCHEDUDLE REFER TO ELECTRICAL DRAWING (E. SERIES) FOR GRAPHIC AND DETAILS NOT ACCEPTABLE TO RUN THE CONDUIT EXPOSED#002 ASI ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A6.0-1 REFLECTED CEILING PLAN- BASEMENT 1/8" = 1'-0"1 RCP00-REFLECTED CEILING PLAN-BASEMENT #159 RFI #159 RFI #159 RFI #159 RFI #159 RFI #159 RFI #159 RFI #159 RFI #159 RFI 12345678910 C D E F G H TODDLERS AND INFANTS 120 GREAT READING ROOM 101 YOUTH STACKS 117 MECH. 113 MEN RR 110 WOMEN RR 111 STORAGE 108 BOOKMOBILE ROOM 103 SORTING 123 I.T. 106 STAFF MEN RESTROOM 105 STAFF-WOMEN RESTROOM 104 ALL GENDER RESTROOM 114 ALL GENDER RESTROOM 115 JAN. RM 112 +8'-0" BOOKSTORE 109 +8'-0" +8'-0" +9'-0" NURSING/SENSORY 116 STORAGE 124 REPLACE (E) 1'X1' CLG TILES WITH NEW TILES, GRIDS AND LIGHTS. YOUTH AREA: NEW ACT TILE AND NEW GRID SYSTEM OFFICE 103A+8'-0"+8'-0" MEETING/COMMUNITY ROOM 102 VESTIBULE 107 +9'-0" +9'-0" VESTIBULE 100 +9'-0" +8'-0" +8'-0" +8'-0"+8'-0" DRAPES AND ROD 15'-8"W X 28' H TRIM BETWEEN CEILINGS @ DIFFERENT HEIGHTS +8'-0" +8'-0" +8'-6" +8'-0" +8'-0" #002 ASI #002 ASI #002 ASI ALIGN TILE PATTEN AT TWO SURFACES #002 ASI +9'-0" +10'-2" #12 RFI #38 RFI 3' - 0 3/4"22' - 0" +7'-6"+7'-6" +8'-0" +8'-0" +9'-0" +9'-0" #43 RFI 1' - 3 3/4"3' - 0 3/4" 2' - 3 3/8" DEMO ABOVE 9'-0 A.F.F. DEMO ABOVE 9'-0 A.F.F. +9'-0" DEMO ABOVE 9'-0 A.F.F. +10'-0" #60 RFI #020 ASI #020 ASI #020 ASI +10'-5" #020 ASI #020 ASI #020 ASI #020 ASI +9'-0" #020 ASI 14 A9.4-1 7 A9.4-1 11 A9.4-1 7 A9.4-1 14 A9.4-1SIM. #020 ASI #120 RFI #109 RFI #120 RFI #120 RFI +7'-6"+7'-6" +9'-4 1/2" +8'-0" HIGH CEILING FOR COMPACT SHELVING. CEILING HEIGHT TO BE VERIFIED WITH SELECTED SHELVING MANUFACTURER #142 RFI #142 RFI #023 ASI 4" 11 ' - 8 " 1' - 7 1 / 4 " 1' - 0 3/4"15' - 4"1' - 8" 5 A9.4-210 A9.4-3 9 A9.4-1 7 A9.4-1 7 A9.4-1 #142.1 RFI #142.1 RFI REFLECTED CEILING PLAN LEGEND G-1: GYPSUM BOARD CEILING PTD. ACT-2: 2'X4' ACOUSTIC CEILING TILE ACT-1: 1'X1' ACOUSTIC CEILING TILE W-1: CUSTOM WOOD GRILLE WITH ACOUSTIC BACKING OPEN TO STRUCTURE ABOVE C -1: CEMENT PLASTER (E) CEILING TO REMAIN #002 ASI 1. 2. LIGHT FIXUTRE AND LIGHTING SCHEDUDLE REFER TO ELECTRICAL DRAWING (E. SERIES) FOR GRAPHIC AND DETAILS NOT ACCEPTABLE TO RUN THE CONDUIT EXPOSED#002 ASI ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A6.0-2 REFLECTED CEILING PLAN- FIRST FLOOR 1/8" = 1'-0"1 RCP01-REFLECTED CEILING PLAN- FIRST FLOOR FE C FE C FEC 12345678910 C D E F G H STUDY 201 STUDY 202 STAFF RESTROOM 2T3 ALL GENDER RESTROOM 2T2 ALL GENDER RESTROOM 2T1 STUDY 220 STAFF MEETING ROOM 221 HISTORY 222 ADULT STACKS 200 VESTIBULE SEATING 200A YOUNG ADULT 211 JAN.RM 217 STAIR 3 2S3 +9'-6" +8'-0"+8'-0"+8'-0" +8'-6" STORAGE 200B MAKER STORAGE 216 +9'-6" OFFICE 226 OFFICE 223 DRAPES AND ROD 15'-8"W X 28' H +9'-6" YA STUDY BOOTH 211A +9'-6" +7'-10" STAFF OFFICE 224 +9'-6" +9'-6" +9'-6" +9'-6" +8'-8" SMOKE CONTAINMENT SYSTEM OFFICE 225+9'-6" +9'-6" +9'-0" +7'-8" ELEC. RM. 218 VIDEO RECORDING BOOTH 214 VIDEO EDITING BOOTH 213 +9'-6" +9'-6"+9'-6" CEILING ABOVE F/F LEVEL OF HISTORY AND OFFICE +7'-8" EXISTING SOFFIT HEIGHT ELEVATION, TO CONFIRM IN FIELD NEW SOFFIT TO MATCH AND ALIGN WITH EXISTING SOFFIT HEIGHT ELEVATION, TO CONFIRM IN FIELD #30 RFI 1 A5.0-65 A5.0-6 +9'-6" +7'-10"+7'-10" #020 ASI #020 ASI #160 RFI +7'-10" V. I . F . 4' - 9 3 / 4 " 8" +7'-10" #204 RFI +7'-8" #204 RFI #204 RFI #204 RFI #204 RFI REFLECTED CEILING PLAN LEGEND G-1: GYPSUM BOARD CEILING PTD. ACT-2: 2'X4' ACOUSTIC CEILING TILE ACT-1: 1'X1' ACOUSTIC CEILING TILE W-1: CUSTOM WOOD GRILLE WITH ACOUSTIC BACKING OPEN TO STRUCTURE ABOVE C -1: CEMENT PLASTER (E) CEILING TO REMAIN #002 ASI 1. 2. LIGHT FIXUTRE AND LIGHTING SCHEDUDLE REFER TO ELECTRICAL DRAWING (E. SERIES) FOR GRAPHIC AND DETAILS NOT ACCEPTABLE TO RUN THE CONDUIT EXPOSED#002 ASI ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A6.0-3 REFLECTED CEILING PLAN- SECOND FLOOR 1/8" = 1'-0"1 RCP02- REFLECTED CEILING PLAN- SECOND FLOOR 6" M I N INTERIOR (E) MARBLE PANELS, REPAIR PER SPECIFICATIONS PUTTY TYP. BOTH SIDES STEEL SASH TO MATCH (E) PUNCH WINDOWS GLAZING (E) INTERIOR PLASTER STEEL TRIM. MATCH (E) 3/8" EXPANSION ANCHOR FOR STEEL APPLICATIONS ROD AND SEALANT INTERIOR MARBLE PANELS TO MATCH (E) ALIGN JOINTS PUTTY TYP. BOTH SIDES STEEL SASH TO MATCH (E) GLAZING ROD AND SEALANT ALONG SILL BACKER ROD AND SEALANT AS REQUIRED MARBLE SILL TO MATCH (E) MTL FLASHING STEEL TRIM INTERIOR PLASTER O/SELF EXPANDED METAL LATH. MATCH ADJACENT FINISH 2" EXP. ANCHOR 6" METAL STUD INFILL WALL W/ INSULATION PER ARCHITECT'S SPECIFICATIONS 1/2" HIGH GRADE PLYWOOD SHEATHING 7/8" EXTERIOR PLASTER O/METAL LATH WRB WRAP AROUND SILL 6" M I N INTERIOR (E) MARBLE PANELS, REPAIR PER SPECIFICATIONS INTERIOR PLASTER. MATCH (E)3/8" EXPANSION ANCHOR FOR STEEL APPLICATIONS CONT. BACKER ROD AND SEALANT. TYP BOTH SIDES 0' - 2 " SHIM HM FRAME DOOR INTERIOR MARBLE PANELS TO MATCH (E) ALIGN JOINTS INTERIOR PLASTER O/SELF EXPANDED METAL LATH. MATCH ADJACENT FINISH EXP. ANCHOR 6" METAL STUD INFILL WALL W/ INSULATION PER ARCHITECT'S SPECIFICATIONS 1/2" HIGH GRADE PLYWOOD SHEATHING CEM. GROUT WRB WRAP AROUND MATCH (E) DOOR HM FRAME SHIM ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A8.7-2 NEW WINDOW DETAILS 6" = 1'-0"2 NEW WINDOW HEAD/JAMB 6" = 1'-0"1 NEW WINDOW SILL NOT USED NOT USED 6" = 1'-0"3 HM DOOR HEAD/JAMB @ (E) CONCRETE 6" = 1'-0"4 HM DOOR JAMB @ INFILL WALL #022 ASI NOTE: 1. AT DOORS,THRESHOLD ACTS AS TRANSITION BETWEEN DIFFERING MATERIALS CARPET, TYPE "1"CARPET, TYPE "2" RES. TILE/ RUBBER CORK CARPET TO RES. TILE/ RUBBER CORK C TRANSITION STRIPCARPET CARPET TO PORCELAIN TILE B1 MARBLE THRESHOLD THIN SET-PORCELAIN TILE CARPET CARPET TO CARPET D SEALED CONCRETE/ EPOXY TO RES. TILE/ RUBBER CORKB2 MARBLE THRESHOLD RES. TILE/ RUBBER CORKEPOXY/ CONCRETE MAX 1:2 (RISE: RUN) IF ADJACENT CARPETS ARE FROM A DIFFERENT MANUFACTURER AND TRANSITION DOES NOT OCCUR AT DOORS, PROVIDE RESILIENT TRANSITION STRIP 1/ 2 " M A X . 3/ 8 " MAX 1:2 (RISE: RUN) LEVELING COMPOUND 1 2 CONC. CARPET TO CONCRETE A ALUM. THRESHOLD CARPET MA X 1/ 2 " MAX SLOPE 1/2 (RISE) 1/ 4 " #139 RFI CO V E B A S E B A D PORCELAIN WALL TILE OVER THINSET BASE COVE BASE TILE W/ 3/8" RADIUS TO MATCH FLOOR TILES THIN-SET PORCELAIN FLOOR TILE PORCELAIN TILE COVE BASE CARPET AT BASE RES. TILE/ RUBBER CORK AT BASE COVE RUBBER BASERES. TILE/ RUBBER CORK STRAIGHT RUBBER BASE CARPET FLOOR C SEALED CONCRETE AT BASE SLIM FOOT BASE SEALED CONCRETESEALANT JOINT LIQUID APPLIED EPOXY COVE BASE E EPOXY BASE CO V E B A S E 4" EPOXY FLOORING 4" VERTICAL CHANGE IN LEVEL WITHOUT EDGE TREATMENT BEVELED CHANGE IN LEVEL MAX 1:2 (RISE:RUN) 1/ 4 " 1/ 2 " 1/ 4 " 1/ 4 " 1 2 TROUGH 6 1/2" B ANTI-TIP RAIL CONCRETE BACK FILL SEE S-SERIES DRAWINGS EXISTING CONCRETE SLAB NON-SHRINK GROUT 1/4" DIA. x 2" EMB. SLEEVE ANCHORS 1 1 / 2 " M I N . TH I C K N E S S O F F L O O R C O N V E R I N G VA R I E S . B A S E D O N NOTE: ALL TROUGH SIDES, BOTTOMS & SURFACE AT EDGE OF TROUGH MUST BE TRUE TO 1/4" OVER 20'-0 SPAN (NON- CUMULATIVE). 1. 2. 3. CONCRETE BACK FILL (TROUGHS) NOTES: FINISHED SLAB MUST MAINTAIN NO MORE THAN 1/4" OVER 20'-1" OUT OF LEVER IN ALL DIRECTIONS. FINISHED SLAB MUST BE NO HIGHER THAN TOP OF FINSHED RAIL MINUS THE THICKNESS OF THE FLOOR OVERING AT ANY POINT. COCRETE BACKFILL & THE CLEANING OF RAILS TO BE DONE BY OTHERS. (E) CONC. SLAB CARPET TILE 3/8" STONE TILE OVER THINSBT CONC.LEVELING COMPOUND SCHIENE 3/8" ALIGN MIN. 2"MAX. 1" RUBBER INTREGRAL TREAD & NOSING; PROVID 2" MIN. WARNING STRIP AT TOP & BOTTOM TREADS RUBBER INTREGRAL TREAD & NOSING; SEE FINISH PLAN ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A9.2-1 INTERIOR DETAILS - FLOOR AND BASE 3" = 1'-0"01 IFL - FLOORING TRANSITIONS 3" = 1'-0"09 IFL - WALL BASE DETAILS 6" = 1'-0"11 IFL - TYPICAL CHANGE IN LEVEL 6" = 1'-0"2 IFL - MOBILE COMPACT SHELVING RECESSED RAIL DETAILS 3" = 1'-0"12 IFL - FLOORING STONE TILE TRANSITION #020 ASI 15 IFL - PATCHING HOLES ON CATWALK PLAN CONDITOIN A: PANEL LEFT IS WIDER THAN 3" CONDITOIN B: PANEL LEFT IS LESS THAN 3" 14 IFL - PATCHING WEB PLATE SECTOIN #107 RFI 3" = 1'-0"10 IFL - RUBBER STAIR TREAD @ STAIR #1, #2 & #3 #016.1 ASI #12 HANGER WIRE TEE GRID SYSTEM ACOUSTICAL CEILING PANELS PERIMETER TRIM 4"H U.N.O. T-BAR CONNECTOR CLIP SEISMIC CLIP "TEGULARIZE" CUT PANELS AT PERIMETER "T" BAR SUSPENDED ACOUSTICAL CEILING PANEL HEMMED ANGLE MOUNDING PARTITION AS SCHEDULED, SEE PLAN FOR TYPE WIRE HANGER 3/4" MIN. 8" MAX. 7/8" NOTE: USE SLIP CONNECTION AT TWO ADJACENT WALLS. AT THE TWO OTHER, SECURE THE MAIN AND CROSS TEES TO THE WALL ANGLE TO FORM A FIXED CONNECTION. VERIFY WITH CEILING MANUFACTURER THE REQ'D CLEAR DIMENSION BETWEEN CEILING TEE AND WALL. (4) 12GA. SPLAY WIRES (ATTACH TO MAIN RUNNER ONLY)@ 45° FROM CLNG. PLANE + 90° FROM EACH OTHER PARALLEL TO CROSS TEES AND MAIN RUNNERS. SPACE @ 12' O.C. MAX BOTH DIRECTIONS. HEAVY DUTY MAIN RUNNER @ 4'-0" O.C. LOCKING CROSS TEES @ 2'-0" O.C. TYP. MAX. MAX. 2" 2" TYP. 12GA. HANGER WIRE ATTACHED TO STRUCTURE ABV. COMPRESSION STRUT. ANGLE CLIP-PINNED TO CEILING STRUCTURE AND BOLTED TO VERTICAL COMPRESSION STRUT TYP. 12 GA. HANGER WIRE @ 4' O.C. + W/IN 8" OF PERIM. WALL OR CLNG. DISCONTINUITY. ADD. WIRES W/IN 3" OF EA. CORNER OF EA. FIXTURE + 2 ADD. WIRES ATTACHED TO OPP. CORNERS OF FIXTURES. COMPRESSION STRUT SEE STRUT CONNECTION DETAIL 3/A9.2-1 FOR ATTACHMENT TO STRUCTURE ABOVE. LOCATE ON MAIN RUNNER ON CENTER OF 12x24 FIELD GRID, STARTING AT MAX. OF 6'-0" FROM PERIMETER.• • • NOTES: 1. AREA OF CEILING PER EACH BRACE NOT TO EXCEED 144 SQ. FT 2. FIRST BRACING POINT WITHIN 6 FT. OF EACH WALL. 3. BRACE POINT ON MAIN RUNNER NOT TO EXCEED 2" DISTANCE FROM CROSS RUNNER. 4. COMPLY WITH CBC 2022 FOR CEILING SUPPORT. 5. AT LIGHT FIXTURES PROVIDE SAFETY CLIPS TO TIE TO CLNG. LIGHT FIXTURE (ALL TYPES) MECHANICALLY ATTACHED TO GRID (TWO PER FIXTURE UNLESS INDEPENDENTLY SUPPORT), REQUIRED FOR: - PENDANT-HUNG FIXTURES DIRECTLY SUPPORTED FROM STRUCTURE WITH 9 GA. WIRE - RIGID LAY-IN OR CAN FIXTURES: LESS THAN OR EQUAL TO 10LBS, ONE WIRE TO STRUCTURE 11-56 LBS: TWO WIRES FROM HOSUING TO STRUCTURE EQUAL TO OR GREATER THAN 57 LBS: SUPPORTED DIRECTLY TO STRUCTURE TOP CLIP (MECHANICALLY FASTENED) SPRING CLIP VERTICAL HANGER WIRE BULB CLIP (MECHANICALLY FASTENED) "T" BAR CROSS TEE "T" BAR MAIN RUNNER TEGULAR ACOUSTIC PANEL WIRE HANGER NOTES: 1. SEE SCHEDULE FOR FINISH CEILING TYPE 2. USE MANUFACTURER RECOMMENDED SEISMIC PERIMETER CONNECTION AT TWO ADJACENT WALLS. AT THE TWO REMAINING WALLS, SECURE THE MAIN AND CROSS TEES TO THE WALL ANGLE TO FORM A FIXED CONNECTION ELEVATION SCHEDULED SUSPENDED CEILING SYSTEM 3/4" MIN8" BRACING WIRES, 12 GAUGE MIN. PLAN 8"6'-0" MAX 12'-0" O.C. 6' - 0 " M A X 12 ' - 0 " O . C . 90°90° 3/4" MIN. CLEAR CROSS RUNNER OR MAIN RUNNERRIGID VERTICAL STRUT @ 12'-0" O.C. I.C.B.O. #2244, SEE DET. 2, 3/A9.4-1 NOTE: TIE MAIN AND CROSS RUNNER TO TWO ADJACENT WALLS THAT WITH FIXIED CONNECTIONS, 7/A9. 4-1. THE OTHER TWO ADJACENT WALLS SHALL BE A SLIPPED CONNECTION, 1/A9.4-1 . 45 , 0 0 ° . PERIMETER VERTICAL HANGER WIRES, TYP. ATTACH SCREW THROUGH EITHER TOP FASTENER OPENING 8 MAX. PERIMETER HANGER WIRE 7/8" SEISMIC CLIP (USG ACM7) PERIMETER CLOSURE (MOLDING) 2 ALIGN .25" MOUNTING HOLE CAM LATCH .625" RECESS PLASTIC GROMMET ADHESIVE MASTIC DRYWALL BEAD HINGE PANEL WIDTH AS SPECIFIED 0' - 2 1 / 2 " ALIGN EDGE MOULDING HANGER WIRE, SEE A9.4-1 & A9.4-2 FOR CONNECTION AND MIN. SPACING REQUIREMENTS SUSPENDED SOFFIT ACT CEILING, SEE RCP B.O. CLG. SEE R.C.P. SOFFIT COLUMN W/ FIREPROOFING, S.S.D. L TRIM 2-1/2 INCH DRML-300 #10 SMS, TYP. 2-1/2" C-CHANNEL ACT CEILING, WHERE OCCURS, SEE RCP SLIP CONNECTION HANGER WIRE, SEE A9.4-1 & A9.4-2 FOR CONNECTION AND MIN. SPACING REQUIREMENTS 1. SIM. REVEALS @ STRUCTURAL PENETRATION OF ACT CLG. 2. 4" ACT. TRIM IN LIEU OF 2 1/2 L TRIM @ ACT CLG. B.O. CLG SEE RCP PER R.C.P. 2 1 / 2 " 2"2" SOFFIT COLUMN W/ FIREPROOFING, S.S.D. L TRIM 2-1/2 INCH DRML-300 #10 SMS, TYP. 2-1/2" C-CHANNEL ACT CEILING, WHERE OCCURS, SEE RCP SLIP CONNECTION HANGER WIRE, SEE A9.4-1 & A9.4-2 FOR CONNECTION AND MIN. SPACING REQUIREMENTS 1. SIM. REVEALS @ STRUCTURAL PENETRATION OF ACT CLG. 2. 4" ACT. TRIM IN LIEU OF 2 1/2 L TRIM @ ACT CLG. B.O. CLG SEE RCP PER R.C.P. 2 1 / 2 " 2"2" JOIST STUD AS NEEDED SEE 04/A9.4-3 SOFFIT FRAMING, #10 SMS, TYP. #142.1 RFI TRANSITION TRIM HANGER WIRE TO STRUCTURE CROSS TEE \MAIN BEAM ACOUSTICAL LAY-IN PANEL HANGER WIRE TO STRUCTURE MAIN BEAM ACOUSTICAL LAY-IN PANEL CROSS TEE ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A9.4-1 INTERIOR DETAILS- CEILINGS 6" = 1'-0"1 ICL- SUSPENDED CLG- SLIP CONNECTION @ PERIMETER 3" = 1'-0"2 ICL- SUSPENDED CLG 3" = 1'-0"3 ICL- SUSPENDED CLG COMPRESSION STRUT 6" = 1'-0"4 ICL- SUSPENDED CLG AT GRID 3" = 1'-0"5 ICL- SUSPENDED CLG PLAN AND ELEVATION 6" = 1'-0"7 ICL- SUSPENDED CLG AT FIXED PERIMETER 3" = 1'-0"8 ICL- ACCESS PANEL AT GYP. BD. CLG 3" = 1'-0"11 ICL - TYP. ACT @ GYP. SOFFIT 1 1/2" = 1'-0"12 ICL - COLUMN @ GYP. SOFFIT CROSS SECTION 1 1/2" = 1'-0"14 ICL - COLUMN @ GYP. SOFFIT CROSS SECTION LONG SPAN #020 ASI #60 RFI 3" = 1'-0"9 ICL - ACOUSTIC CEILING FLOATING EDGE 3" = 1'-0"6 ICL- ACT TRANSITION AT DIFFERENT HEIGHTS #159.1 RFI ∅23_4"MaxRU D LC LC UNIVERSAL CARRIER BEYOND FIXTURE INDEPENDENTLY SUPPORTED IN ACCORDANCE WITH LOCAL BUILDING CODES & LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS 12 GA HANGER WIRE, 48" O.C. MAX SOLID WOOD SLATS 12 GA WIRE HANGER, 48" O.C. MAX SOLID WOOD SLAT ELEVATION PER RCP SOLID WOOD SLAT CLG. FIXTURE @ CLG. PLANE, BLACK FINISH, TYP.; S.E.D., S.M.D., S.T.D. HANGER WIRE 2 1 / 4 " T-BAR MAIN CROSS PIECE BACKER (BLACK; TYP) 1 3/8" 2 1 / 2 " SEE FLOOR PLAN FOR PARTITION TYPE SOLID WOOD SLATS 1" WALL ANGLE HOLD DOWN SOLID WOOD SLAT METAL PANEL SYSTEM ACT PANEL EXPOSED TEE GRID SYSTEM INTERIOR WALL PER PLAN HUNG ACOUSTIC TILE CEILING CLOSURE MOUNT FASCIA 2-7/8" x 2-7/8" x 1/8"TK x 1" METAL WALL MOUNT ANGLE 37_8" 1__16 " 33_4" 1 9__16"1 9__16" ∅23_4" MAX. R.U.D. 15_8" 113__16" 27_8" 1_4" 25_8" 111__16" SH A D E O P E N I N G H E I G H T 7__16" STANDARD BRACKET (DRIVE-END SHOWN) TUBE AND SHADEBAND ASSEMBLY (REGULAR ROLL) SHADECLOTH CONCEALED 1-1/2" (STANDARD) ALUMINUM HEMBAR SEALED INSIDE SHADECLOTH SHADECLOTH IN THE DOWN POSITION DRIVE CHAIN HEMBAR IN THE DOWN POSITION OUTSIDE MOUNT KIT FOR CHAIN TENSIONER, MOUNTED TO THE WALL AT SIDE OF WINDOWS CHAIN TENSIONER ASSEMBLY ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A9.4-2 INTERIOR DETAILS - CEILINGS 3" = 1'-0"1 ICL- SLAT CLG, TYP. @ CEILING FIXTURE 3" = 1'-0"2 ICL - SLAT CLG (PERP), TYP 3" = 1'-0"3 ICL - SLAT CLG. @ PENETRATION 3" = 1'-0"5 ICL - SLAT CLNG (PERP) @GYP. WALL 3" = 1'-0"6 ICL - SLAT CLG. (PERP) @ MTL WALL PANEL 6" = 1'-0"10 ICL - ACOUSTIC CEILING 3" = 1'-0"12 ICL - SHADE @ ACT CEILING W/ CLOSURE AND MOUNT #020 ASI #137 RFI R SM - 1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 SM - 1 SM - 1 SM - 1 SM-1 FOL-2FOL-2FOL-2FOL-2FOL-2 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 SM-1 SM-1 FOL-2 FOL-2 FOL-2 FOL-2 FOL-2FOL-2FOL-2FOL-2 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-2 LOCL-2 LOCL-2 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-2 LOCL-2 LOCL-2 LOCL-2 FE C FE C FE C FE C FE C DW SM - 1 SM - 1 SM - 1 SM - 1 SM - 1 SM - 1 SM - 1 SM - 2 SM - 1 SM-1 SM - 1 SM - 1 SM-1 SM - 1 FE C SM - 1 12345678910 C D E F G H Printer + copierMisc. storage MECH 003 ELEVATOR-ABAN. 007 FIRE AL.RM 006 MECH-ABAN. 008 ARCHIVES 002 STAFF OFFICE 001 OFFICE 012 OFFICE 013 STAFF MEETING ROOM 014 OFFICE 015 ALL GENDER RESTROOM 010 OFFICE 017 Work table Mobile Storage Shelving EXisting Work tables Cabinets Locker & Cabinets Snack Machine Drink Machine Work table Cabinets 5 Drawer lateral file cabinets open shelves MI S C . S t o r a g e Mi s c . S t o r a g e Op e n S h e l v e s STAFF BREAK ROOM 004 (E) ELEV. CONTROL RM. 005A AV C a b i n e t s OFFICE 016 Mobile Storage Shelving ELECTRICAL 019 ELEV. CONTROL 018 PAM Cabinet Mi c r o f i l m C a b i n e t Ve r t c a l Fi l e Ca b i n e t Cabinet STORAGE 005 JANITOR. 023 Misc. storage Misc. storage Special Size Shelve: 36" W x 8" D Media Hanger Rack STORAGE 022 ALL GENDER RESTROOM 011 #104 RFI ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A F R A N CN 4 0 8 0 H I N S L11 AL E CR N D E N VA ,N I N G CRAE TCEIT S C S N N G R O U P 7 S 5 06 C 0718 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- PERMIT SET 1ST ISSUANCE BID SET FINAL PERMIT/CONFORM SET 09/29/2023 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 REV # DESCRIPTION DATE 1 BACKCHECK REV-1 03.01.2024 2 CITY REVIEW REV-1 08.02.2024 3 CITY REVIEW REV-2 10.18.2024 4 CITY REVIEW REV-3 01.27.2025 5 CITY REVIEW REV-4 04.07.2025 6 CITY REVIEW REV-5 06.27.2025 REVIEWED FOR CONSTRUCTABILITY: 80470 SEAN THOMAS. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: RECOMMENDED FOR CONSTRUCTION: 62968 JASON GABRIEL. P.E. RCE NO: PRINCIPAL CIVIL ENGINEER DATE: A9.7-1 SHELVING PLAN BASEMENT 1/8" = 1'-0"1 FP00 - BASEMENT SHELVING PLAN #020 ASI #020 ASI C D E F G H 2345678 W12x50 W1 2 x 3 0 W1 2 x 3 0 W12x50 (E ) C O N C O V E R H O L O R I B M T L D E C K TY P (E ) W 3 0 x (E) W18x @ 6'-0" OC (E ) W 3 0 x (E ) W 3 0 x (E ) W 3 0 x (E) W18x @ 6'-0" OC (E) W18x @ 6'-0" OC 10 19 27' - 7" 17' - 7" 8 S5.0-1TYP TYP (E) COL BELOW TYP 4 S5.0-1 SIM 2 S5.0-1 TYP 2 S5.0-1 TYP 2 S5.0-4 OUTLINE OF ROOF MOVABLE PARTITION PER ARCH BELOW S5.0-3 1 BM TO COL HSS12x4x3/8 HSS12x4x3/8 4 S5.0-4 600S162-54 @ 16" OC (2 ) 6 0 0 S 1 6 2 - 5 4 BO X H E A D E R C15x33.9 C15x33.9 C15x33.9 C15x33.9 C15x33.9 C15x33.9C15x33.9C15x33.9 C15x33.9 C15x33.9 C10x15.3 C10x15.3 W12x40 1 3'-3" 1 7'-2" 1 7'-2" 1 6'-1" 1 6'-2" 17' - 5" 18'-1" 18'-4" 18'-1" 17' - 5" 17' - 7" 27'-6" W10x12 W10x12 W1 0 x 1 2 W10x12 W1 0 x 1 2 W1 0 x 1 2 HS S 4 x 2 x 3 / 8 ( T Y P ) CL CL CL PER LANDSCAPE 10' - 0" HSS12x4x3/8 HSS8x4x1/8 PURLIN. LOCATIONS PER LANDSCAPE 3 S5.0-4 R 28'-5" PER LANDSCAPE R 28'-1" AT Wx BM TO COL 10 S5.0-4 AT PURLIN TO Cx BM 12' - 3" 3' - 6" 2' - 0" 4' - 3" 2' - 6" TOS: +10'-1"TOS: +11'-1"TOS: +10'-6" TOS: +10'-10" C15x (TYP) Wx ( T Y P ) HS S 4 x ( T Y P ) C10x (TYP) HSS12x8x5/8 HSS12x8x5/8 HSS12x8x5/8 TOS: +11'-1" TYP TYP 2' - 6"2' - 0" 3' - 6" 4' - 3" 7 S5.0-4 AT C15x BM TO Wx BMPURLIN LOCATIONS PER ARCH 7' - 9" 4' - 6" HSS14x6x5/8 1 S3.0-1 2 S3.0-1 S2.5-2 4SOUTH PORTAL EAST PORTAL S2.5-2 2 1 S3.0-2 2 S3.0-2 +12'-0" TO SLAB ELEV = (E ) W 1 4 x @ 8 ' - 0 " O C ( V I F ) (E) W21x68 (VIF) (E) W21x68 (VIF) (E) W21x68 (VIF) (E) W21x68 (VIF) (E) W21x68 (VIF) 1 S4.0-4 2 S4.0-4 #29 #29 14 S5.0-1ABV ASI#020 13 S6.0-3 ABV ASI#020 FRAMING PLAN NOTES 1. SEE THESE SHEETS FOR THE FOLLOWING INFORMATION: A. GENERAL NOTES: S0.0-1 THRU S0.0-2. B. ABBREVIATIONS AND SYMBOLS: S0.0-3. C. TYPICAL CONCRETE DETAILS: S4.0-1. D. TYPICAL STEEL DETAILS: S5.0-1. E. TYPICAL METAL STUD DETAILS: S6.0-1 THRU S6.0-4. 2. VERIFY ALL DIMENSIONS, ELEVATIONS FINISH SURFACES,SLOPE, DRAINS, DEPRESSIONS, CURBS, ETC, WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. 3. SPECIFICATIONS AND DETAILING OF ALL WATERPROOFING AND DRAINAGE ITEMS, ALTHOUGH MAY BE INDICATED ON THE STRUCTURAL DRAWINGS FOR GENERAL INFORMATION PURPOSES ONLY, ARE THE DESIGN RESPONSIBILITY OF OTHERS. 4. SEE ARCHITECTURAL DRAWINGS FOR EDGE OF SLAB DIMENSIONS. 5. COORDINATE WITH MECHANICAL/PLUMBING/LANDSCAPE/ ELECTRICAL DRAWINGS FOR REQUIRED SLAB PENETRATIONS. 6. FOR FINISH FLOOR ELEVATIONS, SEE ARCHITECTURAL DRAWINGS. 7. REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ANY DISCREPANCY PRIOR TO CONCRETE PLACEMENT AND NOTIFY THE ENGINEER FOR CORRECTIVE MEASURES. 8. REFER TO ARCHITECTURAL DRAWINGS FOR SLAB ELEVATIONS, DEPRESSIONS, SLOPES, OPENINGS, CURBS, DRAINS, TRENCHES, SLAB EDGE LOCATIONS, HOUSEKEEPING PADS, TIPS, SWALES, EXTERIOR SLAB ETC. AND FOR WALL OVERALL DIMENSIONS, LOCATION OF OPENINGS ETC. NOT INDICATED ON STRUCTURAL DRAWINGS. 9. CENTER COLUMNS ON GRID LINES UNLESS NOTED OTHERWISE. 10. ALL BEAMS ARE SPACED EQUALLY BETWEEN GRIDS OR ALONG SUPPORTING BEAM SPAN UNLESS NOTED OTHERWISE. 11. CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS. 12. 6" MIN SEISMIC GAP BETWEEN FINISHES. TOSL: X'-XX" TOS: X'-XX" INDICATES STEEL COLUMN. SEE PLAN FOR SIZES. INDICATES STEEL BEAM PER PLAN. INDICATES TOP OF SLAB ELEVATION FROM 0'-0" CORRESPONDING TO FIRST FLOOR ELEVATION. INDICATES TOP OF STEEL ELEVATION FROM 0'-0" TYP, UNO ON PLAN. FRAMING PLAN SYMBOLS INDICATES CMU BEARING WALL, SIZE AND REINFORCEMENT PER PLAN. INDICATES DECK TYPE AND SPAN DIRECTION. SEE SCHEDULE ON D# 11/S5.0-1 INDICATES 600S162-54 @ 16" OC WALL. TOP / BOTTOM / SIDE CONNECTION PER AND . 9/S6.0-1 9/S6.0-3 N I R No. S3866 Exp. 3/31/26 G T R E TATSS E OFILACFO UCTURA R L R STEREDP L OFESSIONA N E R AI E ENGI WILLI H.THORP ................ . . . ............................... . . . ............... E AM I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 4/3/2025 11:56:59 AM Autodesk Docs://Santa Ana Library/22575-01 Santa Ana Library_Struct_SR22.rvt S2.4-3 SECOND FLOOR FRAMING PLAN JO B N U M B E R : 2 1 0 0 5 8 8 ; J O B N A M E : S a n t a A n a L i b r a r y R e no v a t i o n ; S H E E T : S 2 . 4 -3; P D : M J S ; P M : E S 1/8" = 1'-0"1SECOND FLOOR FRAMING PLAN REV # DESCRIPTION DATE #29 RFI 12.16.2024 ASI#020 ASI 04.03.2025 (E) Wx BEAM WELD PER DETAIL 5/S5.0-2 (TYP OF (2)) #196 RFI 06.02.2025 #196RFI #196RFI TRANSFER PLATE PER DETAIL 6/S5.0-2 (TYP OF (2)) #3 @ 18" OC 1' - 6 " M A X #3 EPOXY DOWEL @ 3'-0" OC EA WAY (EMBED 1 1/2") SECOND FLOOR #3 @ 18"OC EA WAY SLOPE PER ARCH 18400 Von Karman Ave., Suite 600 Irvine, CA 92612 O: 949.252.1022 F: 949.252.8082 www.kpff.com I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 S4.0-4 CONCRETE DETAILS REV # DESCRIPTION DATE #29 RFI 12.16.2024 1" = 1'-0"2CONCRETE STAIR SECTION 1" = 1'-0"1CONCRETE RAMP SECTION #29 CHIP (E) DECK CONT 1/4" DEEP x 6" LONG NOTES: 1. 2. DO NOT LOCATE EPOXY ANCHORS ABOVE 1 1/2" TALL DECK RIBS. SEE ARCH FOR RAMP DIMENSIONS S4.0-4 #29 1" = 1'-0"2 #3 @ 18" OC #3 CONT NOSING BAR TYP #3 EPOXY DOWEL @ 3'-0" OC (EMBED 1 1/2") AT EA NOSING BAR SECOND FLOOR SEE ARCH FOR STAIR DIMENSIONS NOTES: 1. 2. DO NOT LOCATE EPOXY ANCHORS ABOVE 1 1/2" TALL DECK RIBS. 1" = 1'-0"2 1' - 6 " M A X 4" THICK LWC TOPPING SLAB (3000 PSI, 115 PCF) (E) CONC SLAB & STEPS POUR FOAM RIGID INSULATION 3 #90 #90 RFI 03.11.2025 N I R No. S3866 Exp. 3/31/26 G T RE TATSS E OFILACFO UCTURA R L R STERED P L OF ESSIONA N ER AI E ENGI WILLI H.THORP ............... . . . . .............................. . . . . ............... E AM (2) CONT #3 BARS HOOKED #3 BARS AT 18" OC #3 @ 18" OC #3 CONT NOSING BAR TYP #3 EPOXY DOWEL @ 3'-0" OC (EMBED 1 1/2") AT EA NOSING BAR 1' - 6 " M A X SECOND FLOOR SEE ARCH FOR STAIR DIMENSIONS NOTES: 1. 2. DO NOT LOCATE EPOXY ANCHORS ABOVE 1 1/2" TALL DECK RIBS. CONCRETE STAIR SECTION AT EXISTING STAIRS #91 RFI 03.12.2025 1" = 1'-0"24 1" = 1'-0"25 #91 NOT USED NTS 1" = 1'-0"26 #91 NOT USED NTS 1' - 6 " M A X 4" THICK LWC TOPPING SLAB (3000 PSI, 115 PCF) (E) CONC SLAB & STEPS POUR FOAM RIGID INSULATION (2) CONT #3 BARS #3 DOWLES AT 18" OC VISQUEEN LAYER OR EQUIVALENT NOTES: 1. 2. DO NOT LOCATE EPOXY ANCHORS ABOVE 1 1/2" TALL DECK RIBS. SEE ARCH FOR RAMP DIMENSIONS #90 (E) WALL BY OTHERS EXISTING STAIR INFILL #97 RFI 03.19.2025 1" = 1'-0"27 #91 INFILL OPENINGS IN EXISTING ELEVATED CONCRETE SLAB NTS 10" MIN 24" MAX 10 " M A X 10" MAX 24 " M I N 48 " M A X 24" MIN 48" MAX A A (E) 9" CONC SLAB INFILL W/ HI-FLOW NON-SHRINK GROUT (4000 PSI MIN) W/ SIKA 'FIBERMESH-150' ROUGHEN AND CLEAN EDGE, TYP 1" TYP 2" TYP PL16 GA W/ (4) 1/4"Ø HILTI 'KH-EZ' x 1 5/8" NOMINAL EMBED LO N G E D G E HILTI 'HIT-HY 200 V3' EPOXY W/ 4" EFF EMBED3" TYP 6" MAX #4 LONG DOWELS @ 6" OC MAX (MIN (2) BARS, ADD AS NECESSARY EA ADDTL 6" WIDTH) B B (E) 9" CONC SLAB INFILL W/ HI-FLOW NON-SHRINK GROUT (4000 PSI MIN) ROUGHEN AND CLEAN EDGE, TYP NOTE : 1. SCAN (E) SLAB PRIOR TO DRILLING TO AVOID CUTTING EXISTING REINFORCING BARS. 2. PULL TEST BARS SET IN EPOXY. TEST LOAD = 2,250 # EQ EQ #4 TRANS BARS @ 6" OC SHORT EDGE 10" MAX OPENING 24" MAX OPENING 48" MAX OPENING PL1/4 W/ 3/8"Ø HILTI 'KH-EZ' x 2 1/2" NOMINAL EMBED AROUND PERIMETER EVENLY SPACED (MIN (4) EA SIDE) C (E) 9" CONC SLAB INFILL W/ HI-FLOW NON-SHRINK GROUT (4000 PSI MIN) ROUGHEN AND CLEAN EDGE, TYP EQ EQ #4 DOWELS @ 8" OC MAX EA WAY NOTE : DOWELS TO BE LENGTH OF 'LONG EDGE' - 1" NOTE : DOWELS TO BE LENGTH OF THEIR PARALLEL EDGE - 1" 1 1/2" TYP 3" TYP 3" TYP 8" MAX C NOTE : AT OPENINGS < 6" IN ALL DIRECTIONS, OMIT PL & SCREW ANCHORS 1" = 1'-0 28 #97 CONCRETE MONUMENT SIGN WALL 1" = 1'-0" 8 1/4" CONC WALL (FINISH PER ARCH) SIGN BOX PER ARCH W/ SCREW ANCHORS AT MFR MOUNTING HOLE LOCATIONS ((6) MIN TOTAL) (1/4" Ø x 2 1/2" HILTI 'KH-EZ') SLOPE PER ARCH FINISH GRADE BY OTHERS 6" 1' - 4 " 3'-6" #5 TRANS BARS @ 10" OC #5 VERT BARS @ 18" OC EQ EQ 2 1 / 2 " MI N TY P 2' - 7 " L A P S P L I C E #5 HORIZ BARS @ 18" OC (3) CONT #5 LONG BARS (EVENLY SPACED) 3" TY P DOWELS TO MATCH SIZE AND SPACING OF WALL VERT BARS (ALTERNATE HOOK DIRECTION EA DOWEL) 4' - 6 " MA X 2" CLR TYP CONDUIT BY OTHERS (3/4" MAX) 1" = 1'-0"12NTS9 SHAFT LID #57.1 NOTE : 1. SCAN (E) CONC PRIOR TO DRILLING TO AVOID CUTTING REBAR. 2. APPLY XYPEX TO CONC FOR WATERPROOFING. #57.1 RFI 06.18.2025 1'-6" MAX 6" M I N (E) BLDG CONC WALLQ1 REMOVE (E) LID AND NEATLY CHIP (E) SHAFT WALL (E) CONC SHAFT WALL D2 DECK & END CONN PER 11/S5.0-1 CONT L3X3X1/4 W/ 1/2"ΦX2" EMBED HILTI KB-TZ2 EXP ANCH @ 24"OC MAX (6" FROM ENDS, 4 MIN) EA DECK END STANDARD BOLTED CONNECTION SCHEDULE (2) 7/8"Ø 1/4" (2) 7/8"Ø (3) 7/8"Ø (3) 7/8"Ø (4) 7/8"Ø W21 W18 W16 W14 3/8" 3/8" 3/8" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" WELD SIZE PLATE THICKNESS NO. & SIZE OF BOLTS REQUIRED BEAM SIZE (5) 7/8"Ø (4) 7/8"Ø W12 / C12 W10 / C10 W8 / C8 1. ALL BOLTS TO BE ASTM A325-N IN A SNUG-TIGHTENED JOINT, UNO. 2. CONNECTION PLATES TO HAVE AISC STANDARD ROUND OR HORIZONTAL SHORT-SLOTTED HOLES, UNO. 3. ALL CONNECTION PLATE MATERIAL TO BE A36, UNO. 4. SHOWN ON PLANS INDICATES NUMBER OF BOLTS REQUIRED. IF NOT SHOWN THEN USE THE NUMBER OF BOLTS SHOWN IN THE TABLE ABOVE. # CL BEAM 1/2" 2 1/2" 1 1/2"FOR SHEAR PLATE AND BOLTS SEE SCHEDULE COPE BEAM FLANGE AS REQUIRED SEE SCHEDULE A BEAM TO BEAM TYP 3" TYP 3" TYP 1 1/2" (E) CONCRETE SLAB Wx BM PER PLAN (2) 5/8"Ø HILTI 'KB-TZ2' W/ 4" EMBED @ 12" OC BENT PL1/2 x 3" WIDE AT EACH ANCHOR 1/4 3-SIDES NOTES: 1. USE NON-DESTRUCTIVE TESTING TO LOCATE (E) REINF. DO NOT CUT OR DAMAGE (E) REINF. 2. FIREPROOFING PER ARCH (TYP). GROUT AS REQUIRED FOR FULL BEARING TYP 2" 6" MIN 8" MAX TYP 2 1/2" FOR SHEAR PL & BOLTS SEE PL3/4 W/ (4) 3/4" Ø BOLTS W/ 6" EMBED W/ HILTI 'HIT-HY 200' SEE SCHED ON (E) CONC ELEVATED SLAB (E) CONC BM MAX 1/2" 4" Wx BM PER PLAN 1/S5.0-1 NOTE: USE NON-DESTRUCTIVE TESTING TO LOCATE (E) REINF. DO NOT CUT OR DAMAGE (E) REINF. 1 S5.0-1 (E) CONCRETE SLAB Wx BM PER PLAN (2) 5/8"Ø HILTI 'KB-TZ2' W/ 4" EMBED @ 12" OC AT EDGE CONDIDTION (@ 6" OC AT SIM) BENT PL1/2 x 6" WIDE AT EACH ANCHOR 1/4 3 SIDES NOTE: USE NON-DESTRUCTIVE TESTING TO LOCATE (E) REINF. DO NOT CUT OR DAMAGE (E) REINF. 8" NEW OPENING (E) ELEVATED CONC SLAB 10" MIN 8" MAX (E) CONC FILL OVER MTL DECK L6x4x5/16x1'-6" LG (LLV) W/ (2) 1/2"Ø HILTI 'KB-TZ2' W/ 3 1/4" EMBED INTO (2) LOW FLUTES MIN EA SIDE HSS GAP 1" HSS PER PLAN 5/8"Ø BOLT CENTERED IN 2 1/2" VERT SLOTTED HOLE WASHER EA SIDE MIN 7" 4" 3" 14" 10" TYP 2" 12" CONNECTION PER Wx PER PLAN (E) CONC SLAB (E) CONC BEAM PL3/4 W/ (4) 3/4"Ø BOLTS W/ 6" EMBED W/ HILTI 'HIT- HY 200' NOTE: USE NON-DESTRUCTIVE TESTING TO LOCATE (E) REINF. DO NOT CUT OR DAMAGE (E) REINF. PLATE MAY NEED TO BE RESIZED TO MISS (E) REINF 2" HORIZ SLOT HOLES 1/2" PL x 3" SQ WASHER 3/16 TYP 1 S5.0-1 COL PER PLAN 1/4 1/4 BOLTS PER BEAM PER PLAN WT5x9.5 PLAN CL 1 S5.0-1 1 2 MAX L7x4x3/8 (LLV) EA SIDE OF COL HSS ELEVATOR GUIDE RAIL SUPPORT 3/4"Ø THRU BOLT W/ WASHERS BOTH SIDES AND DOUBLE NUT (HAND TIGHT 1ST NUT) CENTERED IN A 13/16"x 3 1/2" LG VERT SLOTTED HOLE L3x3x1/4 AT COL 1/2"Ø HILTI 'KB-TZ2' W/ 3 1/4" EFF EMBED AT LOW FLUTE (E) CONC FILL OVER STEEL DECK PER PLAN PL1/4x4x0'-6" 1/4 2 MIN 1/4 2 MIN 3/16 3/16 1/4 1/4 2" CLR A A BASE PLATE EQ EQ TYP 1 1/2" TYP 1 1/2" BASE PL3/8 W/ (2) 1/2"Ø HILTI 'KB-TZ2' W/ 2" EFF EMBED 1/4 (2) L8x4x3/8x0'-8" LG (LLV) CLR 1" 1/4 1/4 (E) STL BEAM PER PLAN (1) 5/8"Ø MB CENTERED IN ANGLE & IN HSS 2 1/2" VERT SLOTTED HOLE 1 1/2" A SECTION HSS COLUMN PER PLAN, BOLT HOLES AT CL A SEAM / SIDE LAPINT.END MAX UNSHORED SPAN REINFGAGEMARK EDGE TRIPLEDOUBLESINGLE 12'-0"12'-0"10'-6"1 1/2"16D1 ----VSC @ 24" OCFASTENERS @ 6" OC FASTENERS @ 12" OC FASTENERS @ 12" OC D1 2 1/2"3 1/2" 1 3/4" 1 1/2"6" VERCO PLB-36 STEEL DECK TYPE TOTAL THICKNESS (t) CONCRETE TYPE STEEL DECK ATTACHMENT PATTERN 12'-0"11'-0"10'-0"6 1/4"20D2 #4 @ 12" OC EW 3000 PSI LTWT CONC *3/4"Ø PUDDLE WELD @ 12" OC VSC @ 24" OC*3/4"Ø PUDDLE WELD @ 12" OC *3/4"Ø PUDDLE WELD @ 12" OCVERCO W-3 D2 3/4" CLR 3 1/4" 3" NOTES: 1. SEE GENERAL NOTES FOR MORE INFORMATION. 2. VSC = VERCO SIDELAP CONNECTION. 3. * 3/4" VISABLE DIAMETER PUDDLE WELDS (MINIMUM FUSION AREA SHALL BE 1/2" DIAMETER PUDDLE WELDS). AISC STD HORIZ SHORT SLOTTED HOLES OVERLAPPING 15/16" Ø HOLES ONLY ALLOWING FOR INSTALL OF 3/4"Ø BOLTS NEW SLAB PER PLAN 1/4 1/4 (E) CMU WALL CONT PL1/2 TO MATCH WALL THICKNESS W/ 3/4"Ø x 3 3/4" EMBED HILTI 'KB-TZ2' AT GROUTED CELLS (4 MIN) 1 1/2" TYP 3 1/2" TY 1 1/2" 3/4 EA LOW FLUTE (E) SLAB 7" 7" 2" CL 2" 3"3" 2"A A WALL PLATE Wx PER PLAN (4) 3/4"Ø x 3 3/4" EMBED HILTI 'KB-TZ2' (ICC ESR-4266) PL1/4 HSS COL PER PLAN NOTE: ACCEPTABLE TO USE 3/4"Ø x 4" EMBED HILTI HY 270 EPOXIED THREADED ROD + HIT-CS IN LIEU OF KB-TZ2 WHERE A CELL VOID IS ENCOUNTERED. 3" SCAN SLAB TO LOCATE AND AVOID CUTTING (E) REINF. NEATLY CHIP AWAY CONC TO INSTALL COL. FILL VOID WITH NON-SHRINK GROUT FOR STEEL COL TO BEAM CONN SEE 14 S5.0-4 1/2" . BEAM BELOW EXTEND ANGLE (3) WEBS PAST OPENING EA END TYP THIS IS CONSIDERED A SINGLE OPENING WEBS OF DECKL1 3/4x1 3/4x 1/4 ON TOP OF DECK (TYP) NOTES: 1. DO NOT CUT MORE THAN (2) ADJACENT WEBS 2. INDIVIDUAL HOLES LESS THAN 6"Ø AND CUTTING NO MORE THAN (1) WEB, DO NOT REQUIRE REINFORCING SHOWN. 3. ANGLES SHALL BE PLACED ON TOP OF DECK 4. IF DIMENSION "A" IS GREATER THAN 4x"D1", 4x"D2" OR 32" WHICHEVER IS GREATER, THERE SHALL BE NO RESTRICTION OF DIMENSION "B". 5. IF DIMENSION "B" IS GREATER THAN 4x"D1", 4x"D2" OR 32" WHICHEVER IS GREATER, THERE SHALL NOT BE NO RESTRICTION ON DIMENSION "A" 6. IF DIMENSION "A" AND "B" ARE LESS THAN 4x"D1", 4x"D2" OR 32" WHICHEVER IS LARGER, THE GROUP OF OPENINGS SHALL BE CONSIDERED AS A SINGLE OPENING, AND SHALL BE REINFORCED AS REQUIRED FOR THE LARGER OPENING. "A" "B" "D1" "D2" 1/8 1/2" TYP ADJ TO CUT WEBS MC6x12 (E) MC6x12 L3x3x1/4 BRACE @ EA HANGER 2 MIN 1 (E) L2 1/2x2 1/2 HANGER AT EA (E) ROOF BM 1/4 2-12 1/4 3" MIN EA END PL 3/4x5x0'-8" (E) ROOF BM 1/4 1/4 I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 4/3/2025 11:57:16 AM Autodesk Docs://Santa Ana Library/22575-01 Santa Ana Library_Struct_SR22.rvt S5.0-1 TYPICAL STEEL DETAILS JO B N U M B E R : 2 1 0 0 5 8 8 ; J O B N A M E : S a n t a A n a L i b r a r y R e no v a t i o n ; S H E E T : S 5 . 0 -1; P D : M J S ; P M : E S 1" = 1'-0"1STEEL BM TO STEEL BM CONNECTION 1 1/2" = 1'-0"2FLANGE BRACE TO EXISTING CONC SLAB 1 1/2" = 1'-0"3Wx BEAM TO EXISTING CONCRETE BEAM 1 1/2" = 1'-0"4FLANGE BRACE TO (E) CONC SLAB EDGE 1 1/2" = 1'-0"5HSS TOP CONNECTION AT SLAB 1" = 1'-0"6EMBED PLATE TO CONCRETE BEAM/WALL1 1/2" = 1'-0"10Wx BEAM TO HSS COL CONN 1" = 1'-0"8ELEVATOR GUIDE RAIL SUPPORT 1" = 1'-0"9HSS TOP CONNECTION AT BEAM 1" = 1'-0"11STEEL DECK SCHEDULE 1" = 1'-0"12TYPICAL BEAM TO (E) CMU WALL 1 1/2" = 1'-0"7NOT USED 1" = 1'-0"13TYPICAL STIFFENED DECK SLEEVE DETAIL REV # DESCRIPTION DATE ASI#020 ASI 04.03.2025 I#020 1" = 1'-0"14SECTION ASI#020 1" = 1'-0"1" = 1'-0"215 #142 NEW OPENING IN EXISTING Wx BEAM #142 RFI 04.29.2025 SCHEDULE 40 PIPE SLEEVE x BEAM FLANGE WIDTH SPAN/6 MAX CL OPENING CL B E A M A N D O P E N I N G CL SPAN D 1/4 EA SIDE OF WEB D/2 MAX MIN D/4 2'-0" MAX ~ 2 1 " ( V I F ) 16 " (E) W21x68 (VIF) PIPE 16 STD x 3/8 WALL THICKNESS x 8" LG NOTE: PROVIDE TEMP SHORING FOR EXISTING Wx BEAM PRIOR TO CUTTING NEW HOLE. DO NOT REMOVE SHORING UNTIL PIPE IS INSTALLED AND WELDED TO EXISTING Wx BEAM. ASI# NOTE : SEE DETAIL 3/S5.0-2 FOR CONDITION AT 2ND FLOOR. NOTE : SEE DETAIL 4/S5.0-2 FOR CONDITION AT 2ND FLOOR. #196 RFI 06.02.2025 N I R No. S3866 Exp. 3/31/26 G T R E TATSS E OFILACFO UCTURA R L R STEREDP L OFESSIONA N E R AI E ENGI WILLI H.THORP ................ . . . ............................... . . . ............... E AM #196RFI #196RFI (E) CONC WALL B BASE PLATE 11 ' - 0 1 / 2 " M A X A SECTION (E) CONCRETE WALL SEQUENCE #3: CUT EXISTING CONCRETE WALL OPENING PER PLAN TOP OF SLAB SEQUENCE #1: INSTALL NEW STEEL POSTS AND HEADER HSS POST PER PLAN AA B 13'-0" MAX PER ARCH S4.0-1 10 TYP AT CORNERS (TYP) 1/2" GAP 1' - 0" 1' - 6" C HSS HEADER PER PLAN L4x4x1/4x0'-5" (T&B) (TYP) 1/4 1/4 TYP 1/4 1/4 TYP 1/4 TYP HSS POST PER PLAN EQ EQ L4x4x1/4x0'-4" LONG W/ 5/8" Ø HILTI 'KH-EZ' W/ 3 1/4" EMBED (TYP) M10 HILTI 'HSL4-SK' W/ 2.76" EMBED AT SIM 6" 4' - 0 " O C M A X ( T Y P ) (E) CONC WALL (E) SLAB ON GARDE HSS POST PER PLAN (E) FOOTING 1/4 TYP L4x4x1/4x0'-4" LONG W/ 5/8" Ø HILTI 'KH-EZ' W/ 3 1/4" EMBED (TYP) M10 HILTI 'HSL4-SK' W/ 2.76" EMBED AT SIM 1/4 1/4 C SECTION AT HEADER (E) CONC WALL HSS HEADER 6" PL3/8x6x1'-0" W/ 1/2"Ø HILTI 'KB-TZ2' W/ 2 1/2" EMBED (TYP) CL CL ELEVATION SEQUENCE #2: INSTALL TOP OF HSS POST CONN SEE DETAIL (TYP) 3" 5 S5.0-1 MIN 4" 1/4 1/4 TYP1/4 3-SIDES TYP 11'- 8 3/4" MAX 6" D AT SIM (E) CONC WALL D ALT BASE PLATE 1/4 HSS POST PER PLAN PL3/8x6x0'-9" W/ 1/2"Ø HILTI 'KB-TZ2' W/ 2 1/2" EMBED (TYP) CL EQ EQ B SECTION 1/8 FABRICATORS ALT CHOICE: WELD HSS TO PL3/8 INSIDE HSS PL3/8x3x0'-11" TYP 1 1/2" 8" HSS CENTERED ON PL ANCHOR, TYP CENTERED ON CMU WALL CONT PL3/8 T&B 3/4"⌀'F1554' GR.55 THREADED ROD W/ HILTI 'HY-270' EPOXY (hef = 5 5/8") T&B 1/8 TYP HSS3x2x3/8 B (E) CMU PIER (E) CMU PIER PICKET PER ARCH TOP OF (E) SLAB 3/4"⌀'F1554' GR55 THREADED ROD W/ HILTI 'HIT-HY 200' EPOXY (hef = 3 1/2") T&B (E) CONC BASE C C ALT TO HSS TO CONN PL DIRECT WELD 1/4 1/8 TYP PL3/8 1/8 EA SIDE L3x3x1/4 x 0'-2 1/2" A BOTTOM SUPPORT 4"x4"x3" CONC PEDESTAL AT SPAN'S THIRD POINTS (2 TOTAL) #3 EPOXY DOWEL W/ 1 1/2" EMBED ELEVATION AT END ELEVATION HSS3x2x3/8 NOTE: SEE 10/A8.8-2 FOR ADDITIONAL INFO 18400 Von Karman Ave., Suite 600 Irvine, CA 92612 O: 949.252.1022 F: 949.252.8082 www.kpff.com I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 S5.0-2 STEEL DETAILS 1" = 1'-0"1WALL STRENGTHENING ELEVATION AT NEW OPENING #8 #8 #8 #8 #8 REV # DESCRIPTION DATE #8 RFI 10.18.2024 #11 RFI 10.28.2024 RFI RFI RFI RFI RFI #11 1 1/2" = 1'-0"2SECURITY FENCE ANCHORAGE RFI 1 1/2" = 1'-0"2 (E) CONCRETE SLAB Wx BM PER PLAN (2) 5/8"Ø HILTI 'KB-TZ2' W/ 4" EMBED @ 12" OC BENT PL1/2 x 3" WIDE AT EACH ANCHOR 1/4 3-SIDES NOTES: 1. USE NON-DESTRUCTIVE TESTING TO LOCATE (E) REINF. DO NOT CUT OR DAMAGE (E) REINF. 2. FIREPROOFING PER ARCH (TYP). GROUT AS REQUIRED FOR FULL BEARING (E) CONCRETE SLAB Wx BM PER PLAN (2) 5/8"Ø HILTI 'KB-TZ2' W/ 4" EMBED @ 12" OC AT EDGE CONDIDTION (@ 6" OC AT SIM) BENT PL1/2 x 6" WIDE AT EACH ANCHOR 1/4 3 SIDES NOTE: USE NON-DESTRUCTIVE TESTING TO LOCATE (E) REINF. DO NOT CUT OR DAMAGE (E) REINF. 8" NEW OPENING (E) ELEVATED CONC SLAB 10" MIN 8" MAX FLANGE BRACE TO EXISTINGCONC SLAB @ 2ND FLOOR FLANGE BRACE TO (E) CONCSLAB EDGE @ 2ND FLOOR 1 1/2" = 1'-0"5 1 1/2" = 1'-0"2 3 4 (2) 1/2"Ø HILTI 'KB-TZ2' W/ 2" EMBED @ 12" OC (2) 1/2"Ø HILTI 'KB-TZ2' W/ 2" EMBED @ 12" OC AT EDGE CONDITION (@ 6" OC AT SIM) #196 RFI 06.02.2025 N I R No. S3866 Exp. 3/31/26 G T R E TATSS E OFILACFO UCTURA R L R STEREDP L OFESSIONA N E R AI E ENGI WILLI H.THORP ................ . . . ............................... . . . ............... E AM WELDED CONNECTION ON (E) Wx BEAM 1" = 1'-0"95 (E) W30x BEAM (VIF) (E) W14x BEAM (VIF) TYP PL3/4 x 8 (3) SIDES TYP (E) PL TO (E) W14x WEB 1" 1" 3/16 SEQUENCING NOTE: 1. WELD (E) Wx BEAM WEB TO (E) SHEAR TAB. 2. REMOVE EXISTING SHEAR TAB BOLTS. 3. WELD (N) PL3/4 COMPONENTS. (N) PL TO (E) W14x WEB1/8 16" MIN PJP TYP (N) PL TO (E) W30x WEB1/2 0 #196RFI #196RFI #196RFI SHEAR TRANSFER PLATE 6 3/16 14" MIN #196RFI (E) Wx BEAM SUPPORT BOLTS, TYP (E) W14x BEAM (VIF)W12x BEAM PL1 1/2 x WIDTH PER FIELD x 16" MIN LENGTH 1 1/2" MIN 1 1/2" MIN 3/16 14" MIN VIF (3'-0" MAX) NOTE: NOTIFY SEOR IMMEDIATELY IF THERE IS DIMENSIONAL INCOMPATIBILITY FOR 1 1/2" PLATE BETWEEN BEAM BOTTOM FLANGES. TOP OF W14x BOT FLANGE BOT OF W12x BOT FLANGE 1. A NEW TYPED PANELBOARD DIRECTORY CARD SHALL BE PROVIDED FOR ALL PANELS UNDER THIS CONTRACT. NEW DIRECTORY CARDS SHALL BE LOCATED ON THE INSIDE DOOR OF ASSOCIATED PANELS. 2. ALL NEW CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE AND SHALL BE SUITABLE FOR 75 DEGREES AMPACITY CONDUCTORS. I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 E0.1-5 PANEL SCHEDULES REV # DESCRIPTION DATE #020 ASI 03.21.2025 #008 ASI 04.11.2025 #164 RFI 05.02.2025 #009 ASI 06.04.2025 #009 ASI #009 ASI #009 ASI #009 ASI #009 ASI #009 ASI 1. A NEW TYPED PANELBOARD DIRECTORY CARD SHALL BE PROVIDED FOR ALL PANELS UNDER THIS CONTRACT. NEW DIRECTORY CARDS SHALL BE LOCATED ON THE INSIDE DOOR OF ASSOCIATED PANELS. 2. ALL NEW CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE AND SHALL BE SUITABLE FOR 75 DEGREES AMPACITY CONDUCTORS. I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 E0.1-6 PANEL SCHEDULES REV # DESCRIPTION DATE #008 ASI 04.11.2025 141 RFI 04.21.2025 #003 ASI 11.27.2024 141 RFI 1. ALL FIXTURES SHALL HAVE APPROPRIATE U.L. LABEL, DAMP, OR WET AS REQUIRED BY LOCAL CODES. 2. ALL FIXTURES SHALL INCLUDE ALL ACCESSORIES FOR INSTALLATION ACCORDING TO ALL CALIFORNIA ELECTRICAL CODES. 3. PRIOR TO ORDERING ANY LIGHTING EQUIPMENT, THE CONTRACTOR SHALL VERIFY ALL LOCATIONS AND RECESS DEPTHS. 4. ALL LAMPS SHALL BE INSTALLED ACCORDING TO THE ATTACHED FIXTURE SCHEDULE. 5. CONTRACTOR SHALL VERIFY FINAL VOLTAGES AND CEILING TRIM COMPATIBILITY PRIOR TO ORDERING FIXTURES. 6. CEILING THICKNESS IN EXCESS OF 3/4" SHALL BE IDENTIFIED IN WRITING BY CONTRACT. 7. PROVIDE APPROVED FIRE-RATED ENCLOSURES FOR ALL LIGHTING FIXTURES LOCATED IN A FIRE-RATED CEILING. 8. WALLS DIRECTLY ILLUMINATED SHALL BE INSTALLED AND FINISHED IN A MANNER TO ELIMINATE SHADOWS OR BLEMISHES (I.E. HANG DRY WALL VERTICALLY). 9. ANY FIXTURE SUBSTITUTIONS MUST BE APPROVED BY THE ARCHITECT AND OWNER'S REPRESENTATIVE PRIOR TO BID. CONTRACTOR MUST BE PREPARED TO SUPPLY A SAMPLE AND/OR PHOTOMETRIC DATA IF REQUESTED. 10. OUTDOOR LIGHTING FIXTURES THAT ARE USED TO ILLUMINATE A PREMISES, ARCHITECTURAL FEATURE OR LANDSCAPE FEATURE ON PRIVATE PROPERTY SHALL BE DIRECTED, SHIELDED, OR LOCATED IN SUCH A MANNER THAT THE LIGHT SOURCE IS NOT VISIBLE OFFSITE, TO MINIMIZE LIGHT EMISSION ABOVE THE HORIZONTAL PLANE AND SO THAT LIGHT DOES NOT FALL ONTO SURROUNDING PROPERTIES OR CREATE GLARE HAZARDS WITHIN PUBLIC RIGHTS-OF-WAY. 11. ALL EMERGENCY BATTERY PACKS SHALL BE FURNISHED WITH 90-MIN MINIMUM BACK UP CAPABILITY AND PROVIDE NO LESS THAN 1/3 OF THE FULL LUMEN OUTPUT OF ANY INDIVIDUAL LAMP. LED LIT, TEST SWITCHES TO BE INTEGRAL TO FIXTURE, NOT REMOTE MOUNTED. CONTRACTOR SHALL ENSURE THAT A MINIMUM OF 1-FOOTCANDLE IS PROVIDED AT FLOOR LEVEL ALONG PATH OF EGRESS. 12. LIGHTING INSTALLED IN CORRIDORS AND STAIRWELLS SHALL BE CONTROLLED BY OCCUPANT SENSING CONTROLS THAT SEPARATELY REDUCE THE LIGHTING POWER BY AT LEAST 50% WHEN THE SPACE IS UNOCCUPIED. 13. LIGHTING CONTROL DEVICES AND SYSTEMS, BALLASTS AND LUMINARIES SHALL COMPLY TO 2022 CENC, SECTION 110.9. 14. SHADED FIXTURE INDICATES EGRESS FIXTURE WITH 90 MIN. BATTERY BACKUP OR CONNECTED TO BUILDING LIGHTING INVERTER. 15. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. (CBC 1013.3) 16. ELECTRICALLY POWERED EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924. (CBC SECTION 1013.5 17. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH SECTION 2702. I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 E0.2-1 LIGHTING FIXTURE SCHEDULES GENERAL NOTES REV # DESCRIPTION DATE #184 RFI 05.19.2025 #005 ASI 11.27.2024 #184 RFI R FE C FE C FE C FE C FE C DW FE C P P P P P P MCP FT FT FT FT FT FT J J J J J J J J J 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 CC DD EE FF HH +42" STAFF OFFICE 001 MECH 003 FIRE AL.RM 006 ELEVATOR-ABAN. 007 OFFICE 012 OFFICE 013 STAFF MEETING ROOM 014 OFFICE 015 ELEV. CONTROL 018 OFFICE 017 (E) ELEV. CONTROL RM. 005A +42" LBA-9,11,13&15 LBA-17,19,21&23 LBA-2,4,6&8 LBA-10,12,14&16 LBA-18,20,22&24 ALL GENDER RESTROOM 010 STAFF BREAK ROOM 004 MECH-ABAN. 008 +42" 1 4 ELECTRICAL 019 33 7 7 13 13 9 27 27 27 25 25 1 E4.0-2 STAFF OFFICE 001 LBA-1,3,5&7 ARCHIVES 002 OFFICE 016 1 1 1 1 1 LBM 2 STORAGE 005 2 E4.0-1 DB-2 MS-A TR -T1 LBL LBB LBA 004LBB- 7 10 6 (E) ELECTRICAL VAULT LBB- 12 5 7 7 7 7 7 LP 8 8 8 8 8 8 8 8 2 9 (E) ELEVATOR HYDRAULIC PUMP 7 13 FIRE AL.RM 006 LBA- 10 10 10 10 (E) FA LBA- 4 9 LBA- 710 LBA-31 LBA-25,27&29 2 2 INV-1 LBA- 2 LBB-9&11&13 LBB-21&23 LBB-17&19 23 25 +42"+42" 1012 LBB-8&10&12 LBB-14&16 16 14 DW +18" 4 6 LBB-2&4&6 2 12 20 20 18 18 LBB-18&20 LBB-24 LBB-26 LBB-1&3&5 13 5 555 3 3 1111 44 46 44 44 15 JANITOR. 023 LBA-42 16 17 17 LBB-21 11 LBB-27 17 19 STORAGE 022 ALL GENDER RESTROOM 011 9 +42" 11 11 11 8 RF. +42" +42" +18" +18" #009 ASI #009 ASI #009 ASI #009 ASI #009 ASI #009 ASI 2 25 34 31 32 LBA-32,34&36 29 36 LBB-29 2 18 LBB-18 LBA-35 LBA-39 29 27 #009 ASI #009 ASI #009 ASI 35 35 35 35 I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 E2.4-1 ELECTRICAL REMODEL BASEMENT POWER PLAN 1/8" = 1'-0"1 ELECTRICAL NEW POWER PLAN BASEMENT 1. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET MINIMUM 24 INCHES. 2. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. 3. ALL DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO ROUGH-IN. 4. EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL CONFORM TO CEC, ARTICLE 300.22(C). 5. PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN CIRCUITRY 6. POWER AND DATA CORE AND FACEPLATES TO MATCH COLOR OF ADJACENT WALL. 7. COORDINATE RECEPTACLE LOCATIONS WITH DATA OUTLET LOCATIONS AND GANG DEVICES IN BOXES AND COVER PLATES. 8. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE CONTRACTOR SHALL PROVIDE THE FOLLOWING: 7.1 ALL BRANCH CIRCUITS SHALL BE IN EMT CONDUITS. 7.2 ALL BRANCH CIRCUITS SHALL BE ROUTED, NEATLY AND IN PARALLEL TO STRUCTURES OR DUCT WORK. 7.3 VISUALLY OBJECTIONABLE BRANCH CIRCUITS SHALL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST. 9. PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT WHERE OTHERWISE NOTED. HOME RUN CONDUCTORS MAY BE COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE (9) CURRENT CARRYING CONDUCTORS.WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE (3) ARE INDICATED ON THESE DRAWINGS, THEY HAVE BEEN DERATED AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. 10. NO EQUIPMENT, J-BOXES, ETC. REQUIRING ACCESS SHALL BE LOCATED IN HARD LID CEILING AREAS (UNLESS ACCESS PANEL IS PROVIDED. COORDINATE WITH ARCHITECT.) RELOCATE ANY EXISTING EQUIPMENT, J-BOXES, ETC. TO ACCESSIBLE CEILING AREA. 11. UNLESS SPECIFICALLY SHOWN AS (E), (R), (ER), (D), EXISTING OR NON- BOLD, ALL ELECTRICAL DEVICES SHOWN ARE NEW. 12. CONTRACTOR TO PROVIDE 1/2"CONDUIT WITH PULLSTRING TO ALL NEW THERMOSTAT LOCATIONS. COORDINATE SCOPE OF WORK WITH MECHANICAL DRAWINGS. 13. FLOOR PENETRATIONS SHALL BE FIELD LOCATED TO MISS STRUCTURAL FLOOR FRAMING/REINFORCING BELOW, OTHERWISE, SITE SPECIFIC DETAILS SHALL BE SUBMITTED TO THE CITY FOR APPROVAL PRIOR TO INSTALLATION. CONTRACTOR SHALL SCAN ALL LOCATIONS PRIOR TO CORING. 14. CONTRACTOR SHALL PROVIDE PERMANENT MACHINE TYPE LABELS ON ALL ELECTRICAL EQUIPMENT, RECEPTACLES AND SWITCHES. 15. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH DECORA PLATES. 16. CONTRACTOR TO PROVIDE PERMANENT TYPED LABELS ON ALL EXISTING VAV BOXES DISCONNECT SWITCHES. CONTRACTOR TO REFER TO MECHANICAL DRAWING FOR NUMBER OF VAV BOXES AND LOCATIONS. 17. ALL LOW VOLTAGE DEVICES ARE SHOWN FOR REFERENCE ONLY. 18. ALL RECEPTACLES SHALL BE PROVIDED AS TAMPER RESISTANT RECEPTACLES. 3 SAW-CUT EXISTING SLAB TO ALLOW FOR INSTALLATION OF NEW CONDUIT. WIRE SIZE PER HOMERUN AND ADDITIONAL NOTES. 2 REFER TO TELECOM/AUDIOVISUAL DRAWINGS FOR FLOOR BOX MAKE AND MODEL. FLOOR BOX PROVIDED BY TELECOM OR AUDIOVISUAL CONTRACTOR, COORDINATE IN THE FIELD. CONTRACTOR TO PROVIDE RECEPTACLE CONFIGURATION AND CIRCUITING AS SHOWN ON THE DRAWINGS. 1 CONTRACTOR TO PROVIDE WALL FURNITURE BOX. INSTALL FLEX CONDUIT AS NEED TO CONNECT TO FURNITURE SYSTEM. PROVIDE 3/4''C., 4#10 + 2#10(N), 1#10 EQUIPMENT GROUND FOR ALL FURNITURE FEED CONNECTIONS. TIE EQUIPMENT GROUND AND ISOLATED GROUND CONNECTIONS INTO SINGLE POINT ON FURNITURE FEED WHIP. PROVIDE HANDLE-TIE ON CIRCUIT BREAKERS AS NEEDED. COORDINATE EXACT SIZE AND LOCATION IN THE FEILD WITH THE OWNER'S REPRESENTATIVE. GENERAL NOTES KEY NOTES 4 PROVIDE GFCI RECEPTACLE IN ELEVATOR PIT. 5 CONTRACTOR TO REUSE EXISITNG DISCONNECT SERVING LIGHTING INSIDE ELEVATOR CAB. PROVIDE NEW POWER CONNECTION TO EXISTING DISCONNECT SWITCH. 6 CONTRACTOR TO PROVIDE NEW DISCONNECT SWITCH PER SINGLE LINE DIAGRAM SHEET E0.1-2 FOR EXISTING ELEVATOR. 7 THE LAST CIRCUIT IN THE FURNITURE FEED SHALL BE CONTROLLED BY OCCUPANY SENSOR TO COMPLY WITH THE TITLE 24 CONTROLLED RECEPTACLE CODE REQUIREDMENT, §130.5(d). 8 PROVIDE RECEPTACLE AND CONDUIT SURFACE MOUNTED. CONTRACTOR SHALL INSTALL CONDUIT IN BASEMENT (LEVEL BELOW) AND ROUTE CONDUIT SURFACE MOUNTED UP TO NEW SURFACE MOUNTED RECEPTACLE. 9 PROVIDE POWER CONNECTION TO TWO-WAY COMMUNICATION SYSTEM. REFER TO SHEET TN-7.0-3 FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 10 EXISTING FIRE ALARM PANEL TO BE REUSED. CONTRACTOR SHALL DESIGN-BUILD A COMPLIANT FIRE ALARM SYSTEM PER SPECIFICATIONS SECTION 28 3100. 11 PROVIDE RECEPTACLE AND 120V POWER CONNECTION TO SERVE FAUCET AND SOAP DISPENSER. PROVIDE RECEPTACLE AND 120V POWER CONNECTION TO SERVE HAND DRYER MOTOR. ELECTRICAL BOXES NEED TO BE VERTICALLY, FLUSH MOUNTED TO BACKING MATERIAL, TO ALLOW PLUMBING AND COMPONENT CLEARANCE. COORDINATE EXACT LOCATION AND REQUIREMENTS IN THE FIELD. 12 PROVIDE SWITCH ABOVE COUNTER AND CONNECT TO RECEPTACLE TO SERVE GARBAGE DISCPOSAL. COORDINATE EXACT REQUIREMENTS AND LOCATIONS IN THE FIELD. 13 REFER TO TELECOM/AUDIOVISUAL DRAWINGS SHEET TA9.1-2 FOR TV WALL MOUNT BOX FOR MAKE AND MODEL. WALL BOX PROVIDED BY TELECOM OR AUDIOVISUAL CONTRACTOR, COORDINATE IN THE FIELD. CONTRACTOR TO PROVIDE RECEPTACLE CONFIGURATION AND CIRCUITING AS SHOWN ON THE DRAWINGS. 14 PROVIDE POWER CONNECTION TO DRINKNG FOUNTAIN. COORDINATE EXACT LOCATION AND REQUIREMENTS IN THE FIELD. 15 DEDICATED QUAD RECEPTACLE FOR POWER CONNECTION TO AV RACK. COORDINATE EXACT LOCATION IN THE FIELD. 16 CONTRACTOR TO PROVIDE MOTOR RATED SWITCH AND POWER CONNECTION TO SMOKE CURTAIN. PROVIDE FIRE ALARM CONNECTION AND COORDINATE WITH FIRE ALARM DESIGN-BUILD CONTRACTOR. COORDINATE EXACT REQIREMENTS AND LOCATION IN THE FIELD. 17 CONNECT TO UNDERCABINET LIGHTING AS SHOWN ON E3.0-1. REV # DESCRIPTION DATE #020 ASI 03.21.2025 #008 ASI 04.11.2025 #164 RFI 05.02.2025 #184 RFI 05.19.2025 #009 ASI 06.04.2025 #009 ASI FEC CAENF CAENF CAENF CAENF CAENF CAENF CAENF CAENFCAENF CAENF CAENF CAENF FE C PPFT FT J J J J J J J J J J J J J J J 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 CC DD EE FF HH YOUTH STACKS 117 MECH. 113 ALL GENDER RESTROOM 114 ALL GENDER RESTROOM 115 JAN. RM 112 MEN RR 110 WOMEN RR 111 STORAGE 108 FIREPLACE ROOM 122 SORTING 123 BOOKMOBILE ROOM 103 STAFF-WOMEN RESTROOM 104 STAFF MEN RESTROOM 105 I.T. 106 BOOKSTORE 109 ADULT STACKS 119 GREAT READING ROOM 101 TODDLERS AND INFANTS 120 NURSING/SENSORY 116 YOUTH STACKS 118 1 E4.0-1 STORAGE 124 +42" L1A-9,11,13&15 MEETING/COMMUNITY ROOM 102 1 +42" +42" L1B L1A 2 4 1 1 OFFICE 103A 2 2 1 1 2 2 1 111 1 L1L 5 7 1313 15 15 15 15 15 15 19 17 5 2 2 +32" 6 +12" 1 L1B- 13,15 4 2 2 (TYP. 3) L1B- 25 TODDLERS AND INFANTS 120 25 2525 13 1 2 (TYP) 9 7 8 9 L1B- 27 L1B- 37,39,41 MEETING/COMMUNITY ROOM 102 L1B- 29 29 29 29 29 1BA (E)11 10 L1B- 23 10 10 99 9 9 7 7 7 11 11 L1B-7&9&11 7 11 13 9 L1B-27 L1B-31 L1B-2&4 4 4 2 2 2 L1A-10&12 10 10 10 1210 12 L1B-43& 45&47 L1A-32 L1A-21&23&25 L1A-27,29 10 L1A-31,33 L1A-35 33 27 23 21 21 21 23 6 6 8 8 6 6 9 L1A-6&8 L1A-35 14 14 L1A-20&22 L1A-14&16&18 16 16 18 14 16 16 2 22 20 28 13 13 13 26 28 L1A-26&28&30 2626 26 30 13 LBA-28 FAA12 L1B-27 9 L1B-1&3&5 1 1 1 1 3 3 5 L1B-6 L1A-2&4 44 17 17 17 17 17 L1B-33 L1B-17,19,21 L1A-24 13 14 19 19 13 2424 14 (E) L1B-49,51 15 45,47 43 21 1919 19 19 19 17 L1A-17,19 17 24 L1B-38 16 L1B-38 16 L1B-14 L1B-12 L1B-8 L1B-10 10 10 10 L1A-5 10 L1A-710 +42" 16 L1B-20,22 10 31 29 18 L1B-16,18 20 22 L1B-16,1810 L1B-20,22 17 VESTIBULE 107 32 32 34 34 L1B-32,34 I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 E2.4-2 ELECTRICAL REMODEL FIRST FLOOR POWER PLAN 1/8" = 1'-0"1 ELECTRICAL NEW POWER PLAN - FIRST FLOOR 1. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET MINIMUM 24 INCHES. 2. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. 3. ALL DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO ROUGH-IN. 4. EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL CONFORM TO CEC, ARTICLE 300.22(C). 5. PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN CIRCUITRY 6. POWER AND DATA CORE AND FACEPLATES TO MATCH COLOR OF ADJACENT WALL. 7. COORDINATE RECEPTACLE LOCATIONS WITH DATA OUTLET LOCATIONS AND GANG DEVICES IN BOXES AND COVER PLATES. 8. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE CONTRACTOR SHALL PROVIDE THE FOLLOWING: 7.1 ALL BRANCH CIRCUITS SHALL BE IN EMT CONDUITS. 7.2 ALL BRANCH CIRCUITS SHALL BE ROUTED, NEATLY AND IN PARALLEL TO STRUCTURES OR DUCT WORK. 7.3 VISUALLY OBJECTIONABLE BRANCH CIRCUITS SHALL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST. 9. PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT WHERE OTHERWISE NOTED. HOME RUN CONDUCTORS MAY BE COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE (9) CURRENT CARRYING CONDUCTORS.WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE (3) ARE INDICATED ON THESE DRAWINGS, THEY HAVE BEEN DERATED AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. 10. NO EQUIPMENT, J-BOXES, ETC. REQUIRING ACCESS SHALL BE LOCATED IN HARD LID CEILING AREAS (UNLESS ACCESS PANEL IS PROVIDED. COORDINATE WITH ARCHITECT.) RELOCATE ANY EXISTING EQUIPMENT, J-BOXES, ETC. TO ACCESSIBLE CEILING AREA. 11. UNLESS SPECIFICALLY SHOWN AS (E), (R), (ER), (D), EXISTING OR NON- BOLD, ALL ELECTRICAL DEVICES SHOWN ARE NEW. 12. CONTRACTOR TO PROVIDE 1/2"CONDUIT WITH PULLSTRING TO ALL NEW THERMOSTAT LOCATIONS. COORDINATE SCOPE OF WORK WITH MECHANICAL DRAWINGS. 13. FLOOR PENETRATIONS SHALL BE FIELD LOCATED TO MISS STRUCTURAL FLOOR FRAMING/REINFORCING BELOW, OTHERWISE, SITE SPECIFIC DETAILS SHALL BE SUBMITTED TO THE CITY FOR APPROVAL PRIOR TO INSTALLATION. CONTRACTOR SHALL SCAN ALL LOCATIONS PRIOR TO CORING. 14. CONTRACTOR SHALL PROVIDE PERMANENT MACHINE TYPE LABELS ON ALL ELECTRICAL EQUIPMENT, RECEPTACLES AND SWITCHES. 15. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH DECORA PLATES. 16. CONTRACTOR TO PROVIDE PERMANENT TYPED LABELS ON ALL EXISTING VAV BOXES DISCONNECT SWITCHES. CONTRACTOR TO REFER TO MECHANICAL DRAWING FOR NUMBER OF VAV BOXES AND LOCATIONS. 17. ALL LOW VOLTAGE DEVICES ARE SHOWN FOR REFERENCE ONLY. 18. ALL RECEPTACLES SHALL BE PROVIDE AS TAMPER RESISTANT RECEPTACLES 4 PROVIDE POWER CONNECTION TO DRINKNG FOUNTAIN. COORDINATE EXACT LOCATION AND REQUIREMENTS IN THE FIELD. 2 CONTRACTOR TO PROVIDE POKE-THRU BOX, SIMILAR TO TYPE "FP4" SPECIFIED AND PROVIDED BY TELECOM/AUDIOVISUAL CONTRACTOR, SEE SHEET TN9.0-7. CONTRACTOR TO PROVIDE RECEPTACLE CONFIGURATION AND CIRCUITING AS SHOWN ON THE DRAWINGS. GENERAL NOTES KEY NOTES 5 PROVIDE 120V POWER CONNECTION FOR FIRE PLACE. COORDINATE EXACT LOCATION OF SWITCH IN THE FIELD. 6 RECEPTACLE TO BE MOUNTED 12" A.F.F. FOR BOOKCASE STRIP LIGHTING. 1 REFER TO TELECOM DRAWINGS FOR 2 HOUR FIRE RATED POKE-THRU BOX MODEL. CONTRACTOR TO PROVIDE RECEPTACLE CONFIGURATION AS SHOWN ON THE DRAWINGS. 7 PROVIDE MOTOR RATED SWITCH 120V POWER FOR ROLL-DOWN DOOR. PROVIDE CONTROLS CONNECTIONS BETWEEN DOOR & CONTROL PANEL, NOTE 8, AND COORDINATE REQUIREMENTS IN THE FIELD. 8 PROVIDE 120V POWER CONNECTION FOR ROLL-DOWN DOOR CONTROL PANEL. PROVIDE CONDUITS AND WIRES BETWEEN ROLL-DOWN DOOR AND CONTROL PANEL. COORDINATE EXACT REQUIREMENT IN THE FIELD WITH ROLL-DOWN DOOR SUPPLIER. 9 PROVIDE 120V POWER CONNECTION FOR DOOR OPENER. COORDINATE EXACT REQUIREMENT IN THE FIELD AND WITH SECURITY CONTRACTOR. 10 PROVIDE RECEPTACLE AND 120V POWER CONNECTION TO SERVE FAUCET AND SOAP DISPENSER. PROVIDE RECEPTACLE AND 120V POWER CONNECTION TO SERVE HAND DRYER MOTOR. ELECTRICAL BOXES NEED TO BE VERTICALLY, FLUSH MOUNTED TO BACKING MATERIAL, TO ALLOW PLUMBING AND COMPONENT CLEARANCE. COORDINATE EXACT LOCATION AND REQUIREMENTS IN THE FIELD. 11 PROVIDE 120V POWER CONNECTION FOR NEW MAG-HOLD OPENER. COORDINATE REQUIREMENTS IN THE FIELD. 12 FIRE ALARM ANNUNCIATOR. COORDINATE EXACT LOCATION IN THE FIELD AND WITH APPROVED, BY STATE FIRE MARSHALL AND LOCAL AHJ, FIRE ALARM DRAWINGS PROVIDED BY DESIGN-BUILD FIRE ALARM CONTRACTOR. 13 REFER TO TELECOM/AUDIOVISUAL DRAWINGS SHEET TA9.1-2 FOR TV WALL MOUNT BOX FOR MAKE AND MODEL. WALL BOX PROVIDED BY TELECOM OR AUDIOVISUAL CONTRACTOR, COORDINATE IN THE FIELD. CONTRACTOR TO PROVIDE RECEPTACLE CONFIGURATION AND CIRCUITING AS SHOWN ON THE DRAWINGS. 14 EXISTING FLOOR MOUNTED POKE-THROUGH DEVICE SERVING SECURITY GATES TO REMAIN IN PLACE. RECIRCUIT AS SHOWN AND INDICATED ON DRAWING. COORDINATE EXACT OUTLET TYPE IN THE FIELD WITH SECURITY DOOR VENDOR. 15 PROVIDE FLOOR MOUNTED POKE-THROUGH DEVICE SERVING SECURITY GATES. COORDINATE EXACT LOCATION AND REQUIREMENTS IN THE FIELD, COORDINATE EXACT OUTLET TYPE IN THE FIELD WITH SECURITY DOOR VENDOR. 16 PROVIDE POWER CONNECTION AND MOTOR RATED SWITCH FOR SHADE MOTOR AND PROVIDE SWITCH FOR CONTROL OF (UP/DOWN) OF NEW MOTORIZED SHADES, COORDINATE EXACT LOCATION OF DEVICES AND EXACT REQUIREMENTS IN THE FIELD WITH SHADE VENDOR. 17 PROVIDE WINDOW SHADE CONTROL SWITCH. COORDINATE EXACT LOCATION AND REQUIREMENT IN THE FIELD.REV # DESCRIPTION DATE #020 ASI 03.21.2025 #008 ASI 04.11.2025 141 RFI 04.21.2025 #003 ASI 11.27.2024 141 RFI FE C FE C FEC 2T 2T FT FT J J D D J J J J 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 CC DD EE FF HH STUDY 202 VESTIBULE SEATING 200A HISTORY 222 STAFF RESTROOM 2T3 ALL GENDER RESTROOM 2T2 YOUNG ADULT 211 MAKER STORAGE 216 STUDY 201 +42" +60" +42" +42" +42" YA STUDY BOOTH 211A 54'' 5 5 3 +42"+42" STAFF MEETING ROOM 221 OFFICE 223 STAFF OFFICE 224 OFFICE 226 OFFICE 225 1 L2M L2AL2L JAN.RM 217 2 2 2 1 1 1 1 3 (E) SMR ON RAILING DOWN TO BELOW L2A-16,18,&206 ELEC. RM. 218 INV-2 DDC 3 VIDEO EDITING BOOTH 213 STUDY 220 ALL GENDER RESTROOM 2T1 STORAGE 200B 1 1 L2L-40,42 5 46 46 42 2 42 42 44 42 #10L2A-1&3 35 5 7 7 7 L2A-5&7 3 1 L2A-9&11&13 #10 9 9 911 11 11 13 13 13 13 1 #10 #10 #10 #10 L2A-15&17 15 15 15 17 5 L2A-33 33 33 33 33 L2A-25,27 L2A-61 &63 L2A-35 5 35 35 35 35 31 L2A-31 33 L2A-19&21 31 31 31 4 L2A-39&41&43 41 39 43 43 37 37 37 L2A-37 10 2 2 2 L2A-2 2 2 4 4 4 L2A-4 L2A-53 7 1 1 1 1 1 1 L2A-32 32 32 32 32 5 6 8 8 L2A-6&8&10 3 10 2 10 10 MAKER SPACE 212 18 18 18 18 18 20 22 22 22 22 L2A-18&20&22 VIDEO RECORDING BOOTH 214 24&26 24 L2A-24&26 L2A-28&30 28&30 28 3D PRINTER L2A-12&14&16 12 12 14 16 2 2 44 L2A-48,50 9 L2A-38&40 38 38 4038 L2A-34&36 8 42 42 L2A-42&44&46 11 28&30 24&26 L2A-72 12 12 7 17 17 2 35 2 2 2 L2A-55&57 55 5557 57 55 2 2 41 41 28&30 24&26 46 42 2 L2A-234 L2A-29 4 4 L2A-59 4 4 I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 E2.4-3 ELECTRICAL REMODEL SECOND FLOOR POWER PLAN 1/8" = 1'-0"1 ELECTRICAL NEW POWER PLAN - SECOND FLOOR 1. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET MINIMUM 24 INCHES. 2. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. 3. ALL DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO ROUGH-IN. 4. EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL CONFORM TO CEC, ARTICLE 300.22(C). 5. PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN CIRCUITRY 6. POWER AND DATA CORE AND FACEPLATES TO MATCH COLOR OF ADJACENT WALL. 7. COORDINATE RECEPTACLE LOCATIONS WITH DATA OUTLET LOCATIONS AND GANG DEVICES IN BOXES AND COVER PLATES. 8. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE CONTRACTOR SHALL PROVIDE THE FOLLOWING: 7.1 ALL BRANCH CIRCUITS SHALL BE IN EMT CONDUITS. 7.2 ALL BRANCH CIRCUITS SHALL BE ROUTED, NEATLY AND IN PARALLEL TO STRUCTURES OR DUCT WORK. 7.3 VISUALLY OBJECTIONABLE BRANCH CIRCUITS SHALL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST. 9. PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT WHERE OTHERWISE NOTED. HOME RUN CONDUCTORS MAY BE COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE (9) CURRENT CARRYING CONDUCTORS.WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE (3) ARE INDICATED ON THESE DRAWINGS, THEY HAVE BEEN DERATED AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. 10. NO EQUIPMENT, J-BOXES, ETC. REQUIRING ACCESS SHALL BE LOCATED IN HARD LID CEILING AREAS (UNLESS ACCESS PANEL IS PROVIDED. COORDINATE WITH ARCHITECT.) RELOCATE ANY EXISTING EQUIPMENT, J-BOXES, ETC. TO ACCESSIBLE CEILING AREA. 11. UNLESS SPECIFICALLY SHOWN AS (E), (R), (ER), (D), EXISTING OR NON- BOLD, ALL ELECTRICAL DEVICES SHOWN ARE NEW. 12. CONTRACTOR TO PROVIDE 1/2"CONDUIT WITH PULLSTRING TO ALL NEW THERMOSTAT LOCATIONS. COORDINATE SCOPE OF WORK WITH MECHANICAL DRAWINGS. 13. FLOOR PENETRATIONS SHALL BE FIELD LOCATED TO MISS STRUCTURAL FLOOR FRAMING/REINFORCING BELOW, OTHERWISE, SITE SPECIFIC DETAILS SHALL BE SUBMITTED TO THE CITY FOR APPROVAL PRIOR TO INSTALLATION. CONTRACTOR SHALL SCAN ALL LOCATIONS PRIOR TO CORING. 14. CONTRACTOR SHALL PROVIDE PERMANENT MACHINE TYPE LABELS ON ALL ELECTRICAL EQUIPMENT, RECEPTACLES AND SWITCHES. 15. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH DECORA PLATES. 16. CONTRACTOR TO PROVIDE PERMANENT TYPED LABELS ON ALL EXISTING VAV BOXES DISCONNECT SWITCHES. CONTRACTOR TO REFER TO MECHANICAL DRAWING FOR NUMBER OF VAV BOXES AND LOCATIONS. 17. ALL LOW VOLTAGE DEVICES ARE SHOWN FOR REFERENCE ONLY. 18. ALL RECEPTACLES SHALL BE PROVIDED AS TAMPER RESISTANT RECEPTACLES. 4 PROVIDE RECEPTACLE AND 120V POWER CONNECTION TO SERVE FAUCET AND SOAP DISPENSER. PROVIDE RECEPTACLE AND 120V POWER CONNECTION TO SERVE HAND DRYER MOTOR. ELECTRICAL BOXES NEED TO BE VERTICALLY, FLUSH MOUNTED TO BACKING MATERIAL, TO ALLOW PLUMBING AND COMPONENT CLEARANCE. COORDINATE EXACT LOCATION AND REQUIREMENTS IN THE FIELD. 3 PROVIDE POWER CONNECTION TO DRINKNG FOUNTAIN. COORDINATE EXACT LOCATION AND REQUIREMENTS IN THE FIELD. 2 CONTRACTOR TO PROVIDE POKE-THRU BOX, SIMILAR TO TYPE "FP4" SPECIFIED AND PROVIDED BY TELECOM/AUDIOVISUAL CONTRACTOR, SEE SHEET TN9.0-7. CONTRACTOR TO PROVIDE RECEPTACLE CONFIGURATION AND CIRCUITING AS SHOWN ON THE DRAWINGS. 1 REFER TO TELECOM DRAWINGS FOR 2 HOUR FIRE RATED POKE-THRU BOX MODEL. CONTRACTOR TO PROVIDE RECEPTACLE CONFIGURATION AS SHOWN ON THE DRAWINGS. GENERAL NOTES KEY NOTES 5 REFER TO TELECOM/AUDIOVISUAL DRAWINGS SHEET TA9.1-2 FOR TV WALL MOUNT BOX FOR MAKE AND MODEL. WALL BOX PROVIDED BY TELECOM OR AUDIOVISUAL CONTRACTOR, COORDINATE IN THE FIELD. CONTRACTOR TO PROVIDE RECEPTACLE CONFIGURATION AND CIRCUITING AS SHOWN ON THE DRAWINGS. 6 CONTRACTOR TO INTERCEPT EXISTING CIRCUITS SERVING EXISTING TO REMAIN SURFACE MOUNTED RACEWAY LOCATED ON RAILING. CONTRACTOR SHALL PROVIDE THREE (3) CIRCUITS TO EXISTING RACEWAY AND RECIRCUIT AND LABEL RECEPTACLES AS NEEDED, FOR A COMPLETE INSTALLATION FOR EXISTING TO REMAIN RACEWAY/RECEPTACLE. 7 CONTRACTOR TO INTERCEPT EXISTING CIRCUITS SERVING EXISTING TO REMAIN RECEPTACLES LOCATED IN MEZZANINE LEVEL ABOVE. COORDINATE SCOPE OF WORK IN THE FIELD. 8 CONTRACTOR TO PROVIDE MOTOR RATED SWITCH AND POWER CONNECTION TO PROJECTION SCREEN MOTOR. COORDINATE EXACT REQIREMENTS AND LOCATION IN THE FIELD. 9 CONTRACTOR TO PROVIDE CEILING MOUNTED RECEPTACLE FOR PROJECTOR. COORDINATE EXACT REQIREMENTS AND LOCATION IN THE FIELD. 10 CONTRACTOR TO PROVIDE MOTOR RATED SWITCH AND POWER CONNECTION TO SMOKE CURTAIN. PROVIDE FIRE ALARM CONNECTION AND COORDINATE WITH FIRE ALARM DESIGN-BUILD CONTRACTOR. COORDINATE EXACT REQIREMENTS AND LOCATION IN THE FIELD. 11 CONNECT INVERTER TO PANELBOARD AND CIRCUIT NUMBER AS SHOWN AND INDICATED USING 1"C, 2#4, 1#10GND. 12 CONNECT TO UNDERCABINET LIGHTING AS SHOWN ON E3.0-3. #008 ASI #020 ASI REV # DESCRIPTION DATE #020 ASI 03.21.2025 #008 ASI 04.11.2025 JJ 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 CC DD EE FF HH FC B3 FC B4 FC B5 FC B6 FC B7 FC B8 FC B9 FC B10 FC B2 FC B11 FC B1 M LBM- 1 M LBM- 5 LBM- 7 M M LBM- 9 M LBM- 11 LBM- 13 M M M LBM- 3 M M LBM- 19 M 1 1 1 1 1 1 1 1 7 3 LBM- 2 LBM- 4 LBM- 15 LBM LBA LBB LBL LBM- 6 6 (TYP.) SE-1 SE-2 2"C.O. FOR CONTROLS3/4"C, 3#10 & 1#10GND 5 SEWER EJECTOR CONTROL PANEL 4 2 004 6 EF B-2 EF B-1 (TYP 2) LBM- 38,40,42 LBM- 10 6 FC ELEV FC ELEC LBM- 8 6 2 2 2 4 4 4 4 6 6 DDC LBM-14 3/4"C, 3#10 & 1#10GND LBM-29&31 7 7 LBM-33 6 6 LBM- 17 L2M-20,22,24 M L2M-26 8 9 HPWH-1 CP-1 006 10 006 VFDVFD 008 009 VFD VFD 1 #10 LBM-32,34,36 LBM-21 VAV B-1 M LBM-23 #177 RFI I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 E2.5-1 ELECTRICAL REMODEL BASEMENT MECHANICAL POWER PLAN 1/8" = 1'-0"1 ELECTRICAL REMODEL BASEMENT POWER MECHANICAL PLAN 1. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET MINIMUM 24 INCHES. 2. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. 3. ALL DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO ROUGH-IN. 4. EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL CONFORM TO CEC, ARTICLE 300.22(C). 5. PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN CIRCUITRY 6. POWER AND DATA CORE AND FACEPLATES TO MATCH COLOR OF ADJACENT WALL. 7. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE CONTRACTOR SHALL PROVIDE THE FOLLOWING: 7.1 ALL BRANCH CIRCUITS SHALL BE IN EMT CONDUITS. 7.2 ALL BRANCH CIRCUITS SHALL BE ROUTED, NEATLY AND IN PARALLEL TO STRUCTURES OR DUCT WORK. 7.3 VISUALLY OBJECTIONABLE BRANCH CIRCUITS SHALL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST. 8. PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT WHERE OTHERWISE NOTED. HOME RUN CONDUCTORS MAY BE COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE (9) CURRENT CARRYING CONDUCTORS.WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE (3) ARE INDICATED ON THESE DRAWINGS, THEY HAVE BEEN DERATED AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. 9. NO EQUIPMENT, J-BOXES, ETC. REQUIRING ACCESS SHALL BE LOCATED IN HARD LID CEILING AREAS (UNLESS ACCESS PANEL IS PROVIDED. COORDINATE WITH ARCHITECT.) RELOCATE ANY EXISTING EQUIPMENT, J-BOXES, ETC. TO ACCESSIBLE CEILING AREA. 10. UNLESS SPECIFICALLY SHOWN AS (E), (R), (ER), (D), EXISTING OR NON- BOLD, ALL ELECTRICAL DEVICES SHOWN ARE NEW. 11. CONTRACTOR TO PROVIDE 1/2"CONDUIT WITH PULLSTRING TO ALL NEW THERMOSTAT LOCATIONS. COORDINATE SCOPE OF WORK WITH MECHANICAL DRAWINGS. 3 CONTRACTOR TO PROVIDE 120V POWER CONNECTION TO SERVE AHU UV LIGHTS. COORDINATE EXACT LOCATION OF POWER FEED IN FIELD. 2 CONTRACTOR TO PROVIDE 120V POWER CONNECTION TO SERVE LIGHTING AND RECEPTACLES INSIDE AHU. COORDINATE EXACT LOCATION OF NEW POWER FEED IN THE FIELD. 1 CONTRACTOR TO PROVIDE POWER CONNECTION AND MOTOR RATED SWITCH FOR FAN COIL UNIT. COORDINATE EXACT LOCATION OF SWITCH IN THE FIELD AND WITH MECHANICAL DRAWING M2.1-1 GENERAL NOTES KEY NOTES 4 PROVIDE PANELS WITH OVERCURRENT PROTECTION DEVICES FOR NEW PUMPS. PROVIDE CONTROL PANEL AND EXISTING CONTROLS ARE EXISTING TO REMAIN.ALARM IS SIREN WITH STROBING LIGHT ON THE PANEL. 5 PROVIDE 250V, 30AS/10AF, 3-PHASE, 3-WIRE & GND FUSED DISCONNECT SWITCH TO SERVE SUMP PUMP. LOCATE WITHIN SIGHT OF PUMP. 6 CONTRACTOR TO PROVIDE 120V POWER CONNECTION AND GFCI RECEPTACLE TO SERVE FAN COIL UNIT CONDENSATE PUMP. COORDINATE EXACT LOCATION OF NEW RECEPTACLE IN THE FIELD. 7 POWER TO FAN COIL UNIT FROM OUTSIDE, ROOF MOUNTED, CONDENSING UNIT. CONTRACTOR TO PROVIDE 3/4"C AND CONNECTION TO ROOF MOUNTED CONDENSING UNIT. COORDINATE SCOPE OF WORK WITH SHEET E2.4-4. 8 CONTRACTOR TO PROVIDE 30AS/30AF, 250V, 3-PHASE & GROUND DISCONNECT SWITCH TO SERVE WATER HEATER. 9 CONTRACTOR TO PROVIDE 120V POWER CONNECTION AND MOTOR RATED SWITCH TO SERVE NEW CIRCULATION PUMP. COORDINATE SCOPE OF WORK IN THE FIELD AND WITH PLUMBING DETAILS ON SHEET P2.5-1. 10 CONTRACTOR TO PROVIDE 120V POWER CONNECTION AND MOTORATED SWITCH FOR VAV CONTROLS. EXTEND CIRCUITING TO ALL LOCATIONS IN THE FIELD AND COORDINATE WITH MECHANICAL DRAWINGS, USING 3/4"C, 2/12 & 1#12GND. REV # DESCRIPTION DATE #020 ASI 03.21.2025 #177 RFI 05.21.2025 FEC FE C OS J D D D D OSOS OS OS OS OS OS OS D OS OS OS D OS OS OS OS OS D OS OS O S OS OSOS OS OS OS OS OS OSOS OS OS OS J OS OS OS OS J J OS OS OS J J J OS J 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 CC DD EE FF HH GREAT READING ROOM 101 FAMILY ZONE 121 MECH. 113 ALL GENDER RESTROOM 114 ALL GENDER RESTROOM 115 NURSING/SENSORY 116 JAN. RM 112 MEN RR 110 WOMEN RR 111 FIREPLACE ROOM 122 STORAGE 108 BOOKSTORE 109 SORTING 123 STAFF MEN RESTROOM 105 BOOKMOBILE ROOM 103 OFFICE 103A TODDLERS AND INFANTS 120 MEETING/COMMUNITY ROOM 102 VESTIBULE 107 X X X X X X X X STAFF-WOMEN RESTROOM 104 B1B1 A1 A1 A1 A1 B1 B1 B1B1B1B1 STORAGE 124 1(TYP) 6(TYP) I.T. 106 B1 B1 B1 B1 A1 A1 B3 B3B3 B3 B3 B3 B3 B3 B1 B3B3B3B3 B3 B3 B3B3 5 B1 B1 VESTIBULE 100 H1 B1 B1 B1 B1B1B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1B1 B1B1 X EX EX EX EX H1 H2 B1 B1 B1 B1 B1 B1 B1B1 B1 B1 B1 B1 B1B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 C1 B1 B1 B1 B1 B1 B1 B1 B1 C1 C1 H1H1 H1 H1 H1 C1 C1 B1 B1B1 B1 B1 C1 B1 G1 G1 G1 C1 B1 B1 B1 B1 B3 B3 B1 B1 a,b 11R6 11R6 EM EM EM R5 3R5 3R5 3R5 11R6 EM EM 3b 9a 9a 9a aA19aA19a A1 9a A1 3a EM A1 3a EM A1 3a EM A1 3a EM A1 3a EM A1 3a EM A1 3a EM A1 3b EM A1 3b EM A1 9a A1 9aA19a 9a A1 9a A1 A1A1 B1 A1 3a EM A1 3a EM A1 9a A1 9a a A1A1 A1 A1 A1 A1 A1 A1 9a 9a 9a b 3b a,b b b a B1 9a EM EM 9R3 9R3 3R3 3R3 EM R3 9R3 3R3 EM 3R3 9R3 EM 3R3 R3 EMEM EM EM R2 R3 L1L-9 VIA LCP-1-R2 9R2 9R29R2 9R2 9R3 3R23R2 3R23R2 a EM a EM EMa a 5a 5a a 5a 5a 5a a 3a3a 3a 3a 3a EM EM EM 3a L1L-5 9R4 9R4 R4 a a,b,c 11a 11a 11a 11a11a 11b 11b11b 11b 11b 11b a,b,c a,b a,b 11c 11c EM 1a EX EX EX EX EX EM 1a 7a 7a 7a EM 1a INV-2-3 a,b,c 8 8 8 8 8 c c a,b 8 2 a a a9a a 4EM EX 1a EM 3a 7a EM EXEXEXEXEXEXEX EX EM EX EM EX EM 7a7a7a7a1a 7a7a7a1a 1a 1a 5 B1 B1 B1 B1 7a 7a 7a7a EX EM EX EX EX EM EX EX EX EM EX EX EX EM 7a1a 7a 1a7a7a 1a 7a1a 7a a,b,c 3a 3a 3a 3a3a 3a 3a 3a 3a 3a 3a 3a 3a 3a3a 3a 3a 3a 3a 3a 11 1 4 (TYP) a,b,c 1b & 1c 1a 1a 1a 1a 1a 1a 1a 1a 1a 1a 1a 1a 1a 1a 1a 1a a,b,c 28FT 28FT 28FT 1b & 1c EM L1L-1 2b & 2c INV-2 a,b,c a2 3d 3d 3d 3d 3d 3d 3d 3d 3d 3d 3d 3d 3d 3d 3d d,e,f d,e,f EM EMEM EM a a 2a 2a 2a 2a a EM B1 B1 B1 EM EM 2a 2a 2a 2 2 2 EM EM 5a a3R3 5aa 3R3 5a a EM 12FT 12FT 2e & 2f 3e & 3f INV-2 EM3a & 3c 3b & 3c 2b & 2c INV-2 L1L-3 R4 L1L-9 VIA LCP-1-R3 L1L-9 11a 11a 11a 11a 11a 11a aaaa L1L-11 L1L-11 VIA LCP-1-R6 L1L-11 VIA LCP-1-R5 11a 2 R3 B3 INV-1-6 VIA ELCP R2 2 2 INV-2-3 VIA ELCP-1-R3 INV-2-3 VIA ELCP-1-R2 d,e,f a,b,c EX EM 1a EX EX EX EM 1a 7a 7a 7a EM 1a EX EX a B1 B1 B1 B17a 7a 7a 7a 2 TO FIXTURE IN BASEMENT. REFER TO SHEET E3.0-1 LOCATED ON LEVEL 1 COORDINATE EXACT LOCATION IN THE FIELD 2 L1L a TO FIXTURE IN BASEMENT. REFER TO SHEET E3.0-1 1(TYP.) a 7a 7 1 (TYP.) a 1 (TYP.) 3a 7a L1L-7 VIA LCP-1-R1 1 (TYP.) L1L-29 LCP-1 ELCP-1 INV-2-1 VIA ELCP-1-R1 G1 G1 G1 EM INV-2-3 VIA ELCP-1-R4 (ER) 3 LBL-15 VIA LCP R6 B310 B211cB2B211c 11c X X 4 4 X 4 X 4 X X 4 X 4 4 X 4 (TYP.) C1 C1 9R4 9R4 B3 B3 B3 B3 11a L1A 1. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND ELEVATION OF ALL LIGHTING FIXTURES AND ALL LIGHTING CONTROL DEVICES. ALL WALL MOUNTED DEVICES SHALL BE VERIFIED WITH ARCHITECT PRIOR TO ROUGH-IN. 2. CONTRACTOR SHALL VERIFY CEILING CONSTRUCTION WITH ARCHITECTURAL PLAN AND PROVIDE LIGHTING FIXTURES WILL ALL NECESSARY MOUNTING HARDWARE. 3. CONTRACTOR TO REFER TO DRAWING E0.02 FOR FIXTURE SCHEDULE. 4. CONTRACTOR IS RESPONSIBLE FOR PROVIDING LIGHTING FIXTURES WITH REQUIRED STRUCTURAL SUPPORTS. 5. REFER TO ARCHITECTURAL PLANS FOR EXIT SIGN CHEVRONS AND NUMBER OF FACES PER EXIT SIGN. ANY DISCREPANCIES BETWEEN EXIT SIGNS SHOWN ON ELECTRICAL AND ARCHITECTURAL PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. 6. REFER TO DRAWING E3.03 FOR LIGHTING CONTROL DIAGRAMS AND DETAILS. CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL LOW VOLTAGE WIRING AND COMPONENTS TO PROVIDE A COMPLIANT AND FULLY WORKING LIGHTING CONTROL SYSTEM. CONTROLS DIAGRAMS AND DRAWINGS ARE FOR REFERENCE ONLY AND NOT PRICING AND SHALL NOT BE USE FOR CONTRUCTION. CONTRACTOR SHALL PROVIDE COMPLETE TITLE 24 COMPLIANT LIGHTING CONTROL SUBMITTAL FOR REVIEW AND APPROVAL. 7. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. 8. SWITCH CORE AND FACEPLATES TO MATCH COLOR OF ADJACENT WALL. 9. CONTRACTOR TO PROVIDE JUNCTION BOXES AS NEEDED FOR A COMPLETE LIGHTING INSTALLATION. THESE ARE NOT SHOWN FOR CLARITY OF DRAWINGS. NO JUNCTION BOXES SHALL BE INSTALLED IN HARD-LID CEILINGS. 10. CONTRACTOR TO PROVIDE CONSTANT HOT CIRCUIT TO ALL EXIT SIGNS AND LIGHT FIXTURES PROVIDED WITH 90 MINUTE BATTERY BACKUP FOR EGRESS. 11. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. 12. EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL CONFORM TO CEC, ARTICLE 300.22(C). 13. PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN CIRCUITRY. 14. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE CONTRACTOR SHALL PROVIDE THE FOLLOWING: 14.1 ALL BRANCH CIRCUITS SHALL BE IN EMT CONDUITS 14.2 ALL BRANCH CIRCUITS SHALL BE ROUTED, NEATLY AND IN PARALLEL TO STRUCTURES OR DUCT WORK. 14.3 VISUALLY OBJECTIONABLE BRANCH CIRCUITS SHALL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST. 15. PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT WHERE OTHERWISE NOTED. HOME RUN CONDUCTORS MAY BE COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE (9) CURRENT CARRYING CONDUCTORS. WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE (3) ARE INDICATED ON THESE DRAWINGS, THEY HAVE BEEN DERATED AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. 16. CONTRACTOR SHALL VERIFY WITH LIGHTING CONTROLS MANUFACTURER THE TYPE QUANTITY AND BEST PLACEMENT OF OCCUPANT AND/OR PHOTOCELL SENSORS AS SHOWN ON FLOOR PLAN. PER TITLE 24, OCCUPANT SENSORS SHALL BE MOUNTED AT LEAST 4FT AWAY FROM AIR SUPPLY REGISTER. 17. CONTRACTOR SHALL PROVIDE STARTUP AND COMMISSIONING SERVICES FROM LIGHTING CONTROL MANUFACTURER TO SET UP, ADJUST AND PROGRAM SOFTWARE SYSTEM FOR THE LIGHTING CONTROL SYSTEM TO PROVIDE A COMPLETE AND OPERABLE SYSTEM. 18. NOT ALL JUNCTION BOXES ARE SHOWN ON DRAWINGS. CONTRACTOR SHALL PROVIDE FOR A COMPLETE LIGHTING SYSTEM. 19. PROVIDE AN UN-SWITCHED HOT CIRCUIT WIRING TO ALL EMERGENCY LIGHT FIXTURES AND EXIT SIGNS. 20. CONTRACTOR SHALL INCLUDE IN PRICING, ADDITIONAL 7 EXIT SIGNS, CONDUIT AND WIRING THAT MIGHT BE INSTALLED DURING INSPECTIONS. I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 E3.0-2 ELECTRICAL REMODEL FIRST FLOOR LIGHTING PLAN 1/8" = 1'-0"1 2 - ELECTRICAL RCP PLAN - FIRST FLOOR 1 CONTRACTOR SHALL PROVIDE LIGHT FIXTURE WITH TWO (2) INDIVIDUAL SWTICHLEGS TO CONTROL UPLIGHT FROM DOWNLIGHT. 2 PROVIDE LINE VOLTAGE OCCUPANCY SENSOR FOR THE AREA. 3 LIGHTING IN THIS AREA SHALL BE CONTROLLED VIA TIMECLOCK CONTROLS. OVERRIDE SWITCHES AND OCCUPANCY SENSORS SHALL ONLY WORK DURING OFF HOURS. 4 EXIT SIGNS SHALL BE CONNECTED TO INVERTER PANEL INV-2-14. EXTEND BRANCH CIRCUIT (CONDUIT AND WIRES (2#10 & 1#10 GND)) TO ALL EXIT SIGNS. 5 MANUAL OVERRIDE SWITCH FOR GREAT ROOM LIGHTING. SWITCH SHALL BE IN-ACCESSIBLE DURING NORMAL BUSINESS HOURS. GENERAL NOTES KEY NOTES 6 EXISTING EXIT SIGN LOCATION. REMOVE EXISTING EXIT SIGN AND REPLACE WITH NEW. INTERCEPT EXISTING CONDUIT AND WIRING AND EXTEND TO NEW EXIT SIGN CIRCUIT AS NOTED IN KEYNOTE 4. 7 CONTRACTOR SHALL PROVIDE PARTITION SENSOR FOR CONTROL OF LIGHTING. COORDINATE EXACT SCOPE OF WORK IN THE FIELD WITH PARTITION VENDOR AND LIGHTING CONTOLS VENDOR. 8 CONTRACTOR SHALL PROVIDE SWITCH AND OCCUPANCY SENSORS TO BE INTERLOCKED WITH PARTITION SENSOR FOR CONTROL OF LIGHTING. COORDINATE EXACT SCOPE OF WORK IN THE FIELD WITH PARTITION VENDOR AND LIGHTING CONTROLS VENDOR. 9 CONTRACTOR SHALL NEATLY STORE, PROTECT AND CLEAN EXISTING LINEAR LED LIGHTING DURING DEMOLITION. CONTRACTOR SHALL REINSTALL LINEAR LED FIXTURES, IN NEW LOCATION, AS SHOWN AND INDICATED ON THIS SHEET. 10 PROVIDE A COMLETE LIGHTING CONTROL SYSTEM INCLUDING DEMAND RESPONSE, TIMECLOCK CONTROLS, ETC. FOR COMPLIANCE WITH TITLE 24. REV # DESCRIPTION DATE #191 RFI 05.28.2025 #192 RFI 05.28.2025 #005 ASI 11.27.2024 #192 RFI 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 CC DD EE FF HH (E) 1 1/2" HPS (E) 1" HPC (E) 4" CHWR (E) 4" CHWS TO DISTRICT UTILITY DISTRIBUTION FC B3 FC B4 FC B5 FC B6 FC B7 FC B8 FC B9 FC B10 FC B11 FC B2 FC B1 4"CHWS & R 2" HWS & R 3" CHWS & R 4"CHWS & R2 " CHWS & R 1 1/4" CHWS & R 1" HWS & R 1"CHWS & R 3/4" HWS & R 1" CHWS & CHWR 3/4"⌀HWS & HWR 1" CHWS & CHWR 3/4" HWS & HWR 1" CHWS & R 3/4" HWS & R 1" CHWS & R 3/4" HWS & R 1" CHWS & R 3/4" HWS & R 1"CHWS & R 3/4" HWS & R 1 1/4" CHWS & R 1" HWS & R 1" CHWS & R 1" HWS & R 3/4" HWS & R 3/4" CHWS & R 3/4" HWS & R 3/4" CHWS & R FC ELEV 1 2" HWS & R 3" HWS & R 2 3 HX 1 2 1/2" CHWS & R 4 CHWP 1-2 CHWP 1-1 HWP 1-1 HWP 1-2 1 1/2" HWS & R 1 1/4" HWS & R 1 1/2" CHWS & R1 1/4" CHWS & R 1" HWS & R 3/4" HWS & R 3/4" CHWS & R 1 1/2 " HWS & R 1 1/2" HWS & R 2 " CHWS & R 1 1/4" HWS & R 1 1/4 " CHWS & R 1 1/4"CHWS & R 1" HWS & R 3/4" CHWS & R REFRIGERANT PIPES FC B1-1 5 MECH 003 OFFICE 012 OFFICE 013 STAFF MEETING ROOM 014 OFFICE 015 OFFICE 017 (E) ELEV. CONTROL RM. 005A ARCHIVES 002 ELEV. CONTROL 018 FIRE AL.RM 006 ELEVATOR-ABAN. 007 MECH-ABAN. 008 STAFF OFFICE 001 STAFF BREAK ROOM 004 OFFICE 016 ? ? ALL GENDER RESTROOM 010 I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 M2.2-1 MECHANICAL BASEMENT FLOOR PIPING PLAN 1/8" = 1'-0"1 MECHANICALBASEMENT PIPING PLAN KEY NOTES 1 2" HWS & HWR UP TO FIRST FLOOR 2 2" CHWS & CHWR UP TO FIRST FLOOR 1 1/4" HWS & HWR UP TP FIRST FLOOR 3 MECHANICAL CONTRACTOR CHILLED WATER AND STEAM POINT OF CONNECTION TO EXISTING PIPING. PROVIDE NEW ISOLATION VALVES. 4 4" BUTTERFLY TYPE ISOLATION VALVE WITH ACTUATOR. VALVE ON THE CHILLED WATER RETURN PIPE SHALL BE INTERLOCKED TO CHILLED WATER PUMPS CHWP 1-1 & CHWP 1-2. ISOLATION VALVE SEQUENCE OF OPERATIONS: ON A DEMAND FOR CHILLED WATER (3 FCU/AHU VALVES COMMANDED OPEN MORE THAN 50%, ADJUSTABLE), BEGIN PUMP ENABLE SEQUENCE: •OPEN THE ISOLATION VALVE. •AFTER ISOLATION VALVE IS PROVED OPEN BY THE VALVE END SWITCHES, ENABLE PUMPS. •PUMPS MODULATE TO MAINTAIN CHW DIFFERENTIAL PRESSURE. WHEN CHILLED WATER IS NOT REQUIRED (ALL FCU/AHU VALVES COMMANDED LESS THAN 10%), BEGIN PUMP SHUTDOWN SEQUENCE: •PUMPS ARE DISABLED AND SPEED COMMANDED TO 0. •ISOLATION VALVE IS COMMANDED CLOSED. REV # DESCRIPTION DATE #020 ASI 03.21.2025 #187 RFI 06.10.2025 #001 ASI 08.19.2024 5 REFRIGERANT PIPES UP TO THE ROOF CONNECTED TO OUTDOOR UNIT CU-B1-1 #187 RFI #187 RFI T B-3 T B-1 T B-4 T B-8 T B-2 T B-6 T B-10 T B-11 T B-7 T B-5 TB-9 TVAV-B-1 T FC -B1 -1 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 CC DD EE FF HH 72"x20" 240 CD-2 240 CD-2 240 CD-2 180 CD-2 180 CD-2 180 CD-2 180 CD-2 240 CD-2 240 CD-2 180 CD-2 180 CD-2 180 CD-2 180 CD-2 240 CD-2 240 CD-2 100 CD-1 (TYP. OF 3) 100 CD-1 (TYP. OF 2) (TYP. OF 2) (TYP. OF 2) 14"ø 10"ø 10"ø 14"ø 12"ø 10"ø 8"ø 8"ø 14"ø 12"ø 10"ø 14"ø 12"ø 10"ø 10"ø 10"ø 14"ø 12"ø 10"ø 8"ø 8"ø 14"ø 12"ø 10"ø 14"ø 180 CD-2 240 CD-2 180 CD-2 180 CD-2 240 CD-2 10"ø 32"X30" OUTSIDE AIR 12"ø 10"ø 10"ø 10"ø8"ø 8"ø8"ø 8"ø 180 CD-2 FC B3 FC B4 FC B5 FC B6 FC B7 FC B8 FC B9 FC B1 140 CD-1 10"x10" 6"ø 6"ø 8"ø 8"ø 10"x8" 8"ø 10"x8" 8"ø 8"ø FC B10 FC B2 FC B11 10"x8" 8"ø 8"ø FC ELEV 7DSD7 DSD 7 DSD 7 DSD 7 DSD 7 DSD 7 DSD 1 5 DSD 7 4 3 2 EF B-2 EF B-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 6"ø 8"ø 6"ø 10"ø 8"ø 8"ø 14"ø 14"ø 8"ø 8"ø 10"ø 8"ø 180 CD-1 160 CD-1 6"ø 12"ø 8"ø 16"ø 12 9 8 12 12 12 9 12 10 8 11 13 8"ø 8"ø 8"ø8"ø 8"ø8"ø 8"ø 8"ø 180 SD-5 180 SD-5 180 SD-5 14 FC ELEC ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 8"ø ---- RG-1 6"ø 8"ø U/CU/C 15 15 6 AHU B-1 8"Ø EXHAUST DUCT CONNECTED TO WATER HEATER. 6"ø6"ø 6"x6" VAV B-1 300 SD-4 (TYP.) (TYP. OF 4) FC B1-1 16 300 SD-6 10"ø 12"x10" 12"x12" 14"x14" 10"ø 6"ø 1100 RG-2 MECH 003 OFFICE 012 OFFICE 013 STAFF MEETING ROOM 014 OFFICE 015 OFFICE 017 (E) ELEV. CONTROL RM. 005A ARCHIVES 002 ELEV. CONTROL 018 FIRE AL.RM 006 ELEVATOR-ABAN. 007 MECH-ABAN. 008 STAFF OFFICE 001 STAFF BREAK ROOM 004 399 SF OFFICE 016 ALL GENDER RESTROOM 010 ELECTRICAL 019 STORAGE 022 JANITOR. 023 STORAGE 005 221 SF ELEVATOR LOBBY 009 I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 M2.4-1 MECHANICAL BASEMENT FLOOR PLAN - REMODEL 1/8" = 1'-0"1 MECHANICAL REMODEL PLAN - BASEMENT KEY NOTES 1 EXISTING 60"X36" FLOOR OPENING FOR (E) 60"X36" RETURN AIR TUNNEL. REMOVE AND DISCARD EXISTING FLOOR DAMPER AND REPLACE WITH NEW DAMPER AND AUTOMATED ACTUATOR FOR AIR BALANCING. 2 EXISTING 26"X24" FLOOR OPENING FOR (E) 26"X24" OUTSIDE AIR TUNNEL. REMOVE AND DISCARD EXISTING OUTSIDE AIR FLOOR DAMPER AND REPLACE WITH NEW DAMPER AND AUTOMATED ACTUATOR FOR AIR BALANCING. 3 EXISTING 32"X30" FLOOR OPENING FOR (E) 32"X30" OUTSIDE AIR TUNNEL. REMOVE AND DISCARD EXISTING OUTSIDE AIR FLOOR DAMPER AND REPLACE WITH NEW DAMPER AND AUTOMATED ACTUATOR FOR AIR BALANCING. 4 72"X20"(1"L) SUPPLY AIR DUCT UP TO SECOND FLOOR. 5 72"X20"(1"L) SUPPLY AIR DUCT UP TO FIRST FLOOR 6 8"X6" EXHAUST DUCT UP TO FIRST FLOOR 7 PROVIDE NEW DUCT SMOKE DETECTOR. AUTOMATIVE SHUTOFF SHALL BE ACCOMPLISHED BY INTERUPTING THE POWER SOURCE OF THE UNIT UPON DETECTION OF SMOKE IN THE MAIN SUPPLY AIR DUCT. 8 OUTSIDE AIR VOLUME DAMPER SET @ 60 CFM 9 OUTSIDE AIR VOLUME DAMPER SET @ 90 CFM 10 OUTSIDE AIR VOLUME DAMPER SET @ 110 CFM 11 OUTSIDE AIR VOLUME DAMPER SET @ 130 CFM 12 OUTSIDE AIR VOLUME DAMPER SET @ 160 CFM 13 16"⌀OUTSIDE AIR DUCT UP TO THE ROOF TO SUPPLY FAN SF-1 14 SIEMENS DDC CONTROL PANEL. 15 CEILING EXHAUST FAN PROVIDED WITH BACKDRAFT DAMPER. REV # DESCRIPTION DATE #020 ASI 03.21.2025 #187 RFI 06.10.2025 16 OUTSIDE AIR VOLUME DAMPER SET @ 100 CFM #187 RFI #187 RFI T1-5 T 1-4B T 1-4A T 1-3C T 1-3B T 1-3A T 1-7 T 1-16 T1-17 T 1-18 T 1-13 T 1-12 T 1-11 T 1-10 T 1-14 T 1-6 T 1-2 T1-15 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 CC DD EE FF HH 2000 SD-3 2000 SD-3 1500 SD-2 40"x8"40"x8" 1000 SD-1 1000 SD-1 VAV 1-3B VAV 1-3C-1 VAV 1-3C-2 VAV 1-4A VAV 1-4B 40"x8" VAV 1-5 24"x10" 30 " x 1 2 " 12"x10" 350 CD-5 200 CD-3 VAV 1-13 14"ø 10"ø 50 CD-760"x12" 60"x12" 12"x10" 20"x72" 8"ø 14"ø 14"ø 14"ø14"ø 14"ø 12"ø 12"x10" 50 CD-7 6"ø 200 CD-3 400 CD-6 400 CD-6 400 CD-6 400 CD-6 400 CD-6 400 CD-6 200 CD-3 200 CD-3 200 CD-3 8"ø 350 CD-5 350 CD-5 350 CD-5 200 CD-3 200 CD-3 10"ø 6"ø 6"ø 200 CD-3 200 CD-3 200 CD-3 VAV 1-18VAV 1-15 VAV 1-16 12"ø VAV 1-17 VAV 1-7 2000 SD-3 40"x8"40"x8" 72"x10" 72"x10" 72"x10" 72"x10" 60"x12" VAV 1-3A 14"ø 60"x12"60"x12" VAV 1-128"x10" 8"x6" 6"ø 6"ø 110 CD-4 (TYP. OF 4) 155 CD-3 (TYP. OF 2) 24"x10" 12 " x 1 0 " 12 " x 1 0 " 8"ø (TYP.) (TYP. OF 4) (TYP. OF 4) CSFD CSFD FC IT VAV 1-2 30 " x 1 2 " 1000 SD-1 1000 SD-1 24"x10" 2 1 3 4 CSFD CSFD5 40"x6" 40"x6" 10"ø 10"ø 2000 SD-3 2000 SD-3 300 EG-1 160 CD-8 100 EG-2 6"ø 10"ø 10"ø 100 EG-2 250 EG-1 300 TG-1 300 TG-1 600 TG-2 VAV 1-11 48 " x 1 2 " 6"ø 12"ø 6 7 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 8"ø VAV 1-6 8"ø 8"ø 12"ø 12"ø 72"x24" 8 9 10 8"x6" 11 200 CD-1 (TYP. OF 6) 8"ø 8"ø 8"ø10"x8" 10"x8" 10"x8" 8"ø 8"ø 8"ø 8"ø 8"ø10"x8" 230 CD-1 (TYP. OF 6) 16"x12" 20"x12" 8"ø 12"x8" 8"ø 8"ø 12"x8" 8"ø 8"ø 12"x8" 8"ø 24"x12" 30"x12" 18"x12" 24"x12" 12"x12" 210 CD-1 (TYP. OF 2) 26"x12" ---- RG-1 (TYP. OF 10) AHU 1-1 100 EG-2 (TYP. OF 2) 8"x6" 6"ø 6"ø 16"x10" 10"ø 10"ø 6"ø 100 EG-2 24"x10" 12 30"x12" 14"x12" 12"ø 10"ø 10"ø 10"ø 8"ø 10"ø 12"ø 8"ø 8"ø 10"ø 14"ø VAV 1-14 ---- RG-1 ---- RG-1 8"ø 12"ø 12"ø 10"ø8"ø 40"x8" 8"ø VAV 1-10 8"x8" 8"ø8"ø 6"ø CSFD 13 20"x72"R.A 14 GREAT READING ROOM 101 YOUTH STACKS 117 MECH. 113 ALL GENDER RESTROOM 114 ALL GENDER RESTROOM 115 NURSING/SENSORY 116 JAN. RM 112 MEN RR 110 WOMEN RR 111 FIREPLACE ROOM 122 STORAGE 108 BOOKSTORE 109 SORTING 123 STAFF MEN RESTROOM 105 BOOKMOBILE ROOM 103 OFFICE 103A TODDLERS AND INFANTS 120 STAFF-WOMEN RESTROOM 104 FAMILY ZONE 121 MEETING/COMMUNITY ROOM 102 I.T. 106 I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 M2.4-2 MECHANICAL FIRST FLOOR PLAN - REMODEL 1/8" = 1'-0"1 MECHANICAL REMODEL PLAN - FIRST FLOOR KEY NOTES 1 24"X10" EXHAUST DUCT UP TO THE SECOND FLOOR. 2 12"X10" EXHAUST DUCT UP TO THE SECOND FLOOR. 3 72"X20"(1"L) SUPPLY AIR DUCT UP TO THE SECOND FLOOR AND DOWN TO THE BASEMENT. 4 72"X20"(1"L) SUPPLY AIR DUCT DOWN TO THE BASEMENT. 5 NEW AIR HANDLING UNIT. REFER TO MECHANICAL EQUIPMENT SCHEDULES. 6 16"⌀OUTSIDE AIR DUCT UP TO THE ROOF TO SUPPLY FAN SF-1. 7 SIEMENS DDC CONTROL PANEL. 8 CONNECT NEW OUTSIDE AIR DUCT TO EXISTING AIR INTAKE WALL LOUVER. 9 8' x 2' EXISTING OUTSIDE AIR INTAKE LOUVER TO BE REPLACE WITH 8' x 2' NEW OUTSIDE AIR INTAKE LOUVER. 10 3' x 2' EXISTING OUTSIDE AIR INTAKE LOUVER TO BE REPLACE WITH 3' x 2' NEW OUTSIDE AIR INTAKE LOUVER. 11 8"X6" EXHAUST DUCT DOWN TO THE BASEMENT LEVEL 12 O.A VOLUME DAMPER SET @ 850 CFM REV # DESCRIPTION DATE #020 ASI 03.21.2025 #142 RFI 04.28.2025 #178 RFI 06.10.2025 13 24"X24" WALL ACCESS PANEL TO ACCESS DUCT MOUNTED COMBINATION FIRE SMOKE DAMPER AT FLOOR PENETRATION. #178 RFI #178 RFI 14 COMBINATION FIRE SMOKE DAMPER TO BE INSTALLED AT FLOOR PENETRATION. T 2-11 T 2-13 T 2-12 T 2-8 T 2-6 T 2-1 T 2-2 T 2-3 T2-5 T 2-4 T 2-15T2-9 T T 2-14 T 2-16 FE C FE C FEC 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 CC DD EE FF HH 400 CD-6 300 CD-5 10"ø 12"ø VAV 2-1 300 CD-5 150 CD-3 VAV 2-3 8"ø10"ø 300 CD-5 400 CD-6 400 CD-6 10"ø 8"ø 150 CD-3 VAV 2-2 10"ø 14"ø 8"ø 150 CD-3 VAV 2-5 14"ø 10"ø 8"ø 24 " x 1 2 " 60"x12"8"ø 12"ø 400 CD-6 600 CD-6 200 CD-3 VAV 2-6 12"ø 8"ø 8"ø 12"ø 1000 CD-9 1000 CD-9 1000 CD-9 60"x12" VAV 2-8 350 CD-5 350 CD-5 200 CD-3 200 CD-3 400 CD-6 400 CD-6 400 CD-6 400 CD-6 400 CD-6 8"ø 8"ø 8"ø 14"ø 12"ø 8"ø 8"ø 12"ø 24 " x 1 2 " 10"ø 14"ø 18"ø 8"ø 12"ø 8"ø 8"ø 8"ø VAV 2-11 VAV 2-14 200 CD-3 200 CD-3 12"ø 12"ø 12"ø 12"ø 14"ø 200 CD-3 VAV 2-12 8"ø 12"x10"10"ø10"ø 10"ø 200 CD-3 14"ø 12"ø 24 " x 1 2 " 150 CD-3 150 CD-3 VAV 2-13 VAV 2-4 15 CSFD 3 2 CSFD 4 EF 2-1 EF 2-2 EF 2-3 6"ø6"ø6"ø 6 ---- RG-1---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 ---- RG-1 7 8 10"ø 8"ø VAV 2-16 200 CD-3 200 CD-3200 CD-3 8"ø 8"ø 250 CD-5 250 CD-5 10"ø10"ø ---- RG-1 ---- RG-1 10"ø8"ø 200 CD-3 8"ø VAV 2-15VAV 2-9 9 9 24"x16" 24"x16" 10 11 (TYP.)8"ø 8"ø 12EF 2-4 12"ø (TYP. OF 6) (TYP. OF 2) U/CU/CU/C 16"x10" 22"x14" 22"x12" 16"x1 0 " 22"x8" (E) 22"x14" 6 STUDY 201 VESTIBULE SEATING 200A JAN.RM 217 ALL GENDER RESTROOM 2T1 ALL GENDER RESTROOM 2T2 STAFF RESTROOM 2T3 STUDY 220 STAFF MEETING ROOM 221 STUDY 202 STAIR 3 2S3 MAKER STORAGE 216 OFFICE 226 OFFICE 223 STAFF OFFICE 224 STORAGE 200B YA STUDY BOOTH 211A YOUNG ADULT 211 HISTORY 222 OFFICE 225 ADULT STACKS 200 ELEC. RM. 218 MAKER SPACE 212 VIDEO EDITING BOOTH 213 VIDEO RECORDING BOOTH 214 I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 M2.4-3 MECHANICAL SECOND FLOOR PLAN - REMODEL 1/8" = 1'-0"1 MECHANICAL REMODEL PLAN - SECOND FLOOR KEY NOTES 1 72"X20" (1"L) SUPPLY AIR DUCT DOWN TO BASEMENT PLAN. 2 24"X10" EXHAUST DUCT DOWN TO FIRST FLOOR. 3 12"X10" EXHAUST DUCT DOWN TO FIRST FLOOR. 4 24"X10" EXHAUST DUCT UP THRU THE ROOF TO EXHAUST FAN EF 1-1. 5 12"X10" EXHAUST DUCT UP THRU THE ROOF TO EXCHANGE FAN EF 1-2. 6 6"⌀EXHAUST DUCT UP THRU THE ROOF. TERMINATE WITH ROOF CAP 6" MINIMUM ABOVE THE ROOF. 7 16"⌀OUTSIDE AIR DUCT UP TO THE ROOF TO SUPPLY FAN SF-1 8 SIEMENS DDC CONTROL PANEL. 9 40"X 24" TRANSFER AIR GRILLE TO MATCH EXISTING LOCATION. 10 72"X 20" RETURN AIR OPENING. 11 CEILING RETURN SOUND BOOT. SEE DETAIL 5/ M4.0-1 12 8" EXHAUST AIR DUCT UP THRU THE ROOF. TERMINATED WITH ROOF CAP. REV # DESCRIPTION DATE RFI-53 02.19.2025 #020 ASI 03.21.2025 #178 RFI 06.10.2025 #178 RFI 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 CC DD EE FF HH EF 1-2 EF 1-1 CU IT CU ELEV 2 1 CU ELEC 3 4 4 SF B1 16"ø 5 55 6 444 777 CU B1-1 8 5 I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 M2.4-4 MECHANICAL ROOF PLAN - REMODEL 1/8" = 1'-0"1 MECHANICAL ROOF PLAN KEY NOTES 1 24"X10" EXHAUST DUCT DOWN THRU THE ROOF. 2 12"X10" EXHAUST DUCT DOWN THRU THE ROOF. 3 16"⌀OUTSIDE AIR DUCT DOWN THRU THE ROOF. 4 EXHAUST AIR TERMINATION SHALL BE NOT LESS THAN 10 FEET FROM OUTSIDE AIR INTAKE. 5 8" MINIMUM ROOF LEVEL PAD (SEE DETAIL 7 / M4.0-3) 6 8" EXHAUST AIR DUCT UP FROM SECOND FLOOR. 7 6"⌀EXHAUST DUCT DOWN THRU THE ROOF TO THE SECOND FLOOR. REV # DESCRIPTION DATE #020 ASI 03.21.2025 #187 RFI 06.10.2025 8 REFRIGERANT PIPES DOWN THRU THE ROOF. #187 RFI #187 RFI ~ ~ ~ ~ CHILLED WATER COIL AIR HANDLING UNIT PIPING DIAGRAM SCALE: NOT TO SCALE AIR HANDLING UNIT ATTACHEMENT SCALE: NOT TO SCALE VAV TERMINAL DETAIL SCALE: NOT TO SCALE PUMP DETAIL SCALE: NOT TO SCALE STEAM HEAT EXCHANGER PIPING SCALE: NOT TO SCALE VAV REHEAT COIL DETAIL SCALE: NOT TO SCALE CONDENSING UNIT DETAIL SCALE: NOT TO SCALE COOLING COIL CONDENSATE TRAP SCALE: NOT TO SCALE CU -- STEAM MAIN STRAINER FULL SIZE BY-PASS STEAM CONTROL 0-60 PSIG PRESS 0-30" HG. VAC. COMPOUND GAUGE FULL SIZE BY-PASS (CONVERTER) HEAT EXCHANGER STRAINER TO FS DIRT LEG FOR VACUUM BREAKER SWING CHECK BLOW-OFF VALVE CONDENSATE RETURN SWING CHECK STEAM TRAP AUTOMATIC HOFFMAN 78 AIR VENT (TYP.) GRISWOLD FLOW CONTROL VALVE COOLING UNION (TYP.) COIL W/WELL (TYP.) THERMOMETER TRERICE 9" P TO SUPPLY HOSE END VALVE S.O.V. STRAINER WITH MAIN TO RETURN (CONTROLLED BY DDC. AUTOMATIC TEMPERTURE CONTROL VALVE CONTROLLER) S.O.V. PRESSURE GAUGE MAIN PETES PLUG (TYP.) RECTANGULAR OR ROUND MAIN SUPPLY DUCT. VAV TERMINAL HEATING COIL MANUAL VOLUME DAMPERS AT EACH TAKE-OFF. 45° ENTRY BRANCH TAKE-OFF SHEET METAL PLENUM WITH 1" LINER. 1/8" WIRE ROPE (TYP) THIMBLE (TYP) CROSBY FORGED WIRE ROPE CLIP. INSTALL TWO PER CABLE END PER MANUFACTURER'S INSTRUCTIONS (TYP) DUCT TRANSITION SEE 7/M5.3 DETAIL FOR UPPER ATTACHMENT (TYP) SLACK AIRCRAFT CABLE (TYP.) PETES PLUG STRAINER & W/ INTEGRAL BELIMO 3-WAY BALL VALVE FOR MANUAL AIR 1/4" GUAGE COCK VENTING CHARACTERIZED UNION (TYP.) AIRFLOW COIL PETES PLUG STRAINER & W/ INTEGRAL CONTROL VALVE BELIMO PICCV BALL VALVE FOR MANUAL AIR 1/4" GUAGE COCK VENTING PETES PLUG (TYP.) UNION (TYP.) AIRFLOW COIL SEE ZONE SCHEDULES FOR THREE WAY VALVE LOCATIONS ISOLATION BALL VALVE CONTROL VALVEPRESSURE INDEPENDENT FLOW CONTROL VALVE ISOLATION BALL VALVE BALANCING VALVE TO FAN COIL UNIT REFRIGERANT LINES 8" ROOF LEVEL PAD ROOF LEVEL NOTE: EXTERIOR GAS LINE TO HAVE 3/4" ARMAFLEX INSULATION WRAPPED WRAPPED W/ ALUMINUM JACKETING AND VAPOUR SEALED. ISOLATION PADS. ONE EACH CORNER (MIN. OF 4). 24 GAGE GALVANIZED SHEET METAL FLASHING CAP. NAIL TO CURB. FINISHED ROOF 4" HIGH CANT STRIP ALL AROUND. ROOF STRUCTURE (2) #10 SMS EA 4"x 4"x 1/8" ANGLE (4)TOTAL STRAIGHT INLET DUCT SHALL BE MINIMUM 3 DUCT DIAMETERS IN LENGTH. CONDENSATE PUMP 3/4" BALL VALVE (TYP) PRESSURE GAUGE FOR CHECK AND FOR SHUTOFF CONTROL) BALANCING CONTROL (NOT TO BE USED TRIPLE DUTY VALVE GATE OR BALL VALVE PETE'S PLUG (TYP) BUTTERFLY VALVE FOR VICTAULIC COUPLING (TYP) SHUTOFF CONTROL (TYP OF 2) PIPE SUPPORT (TYP.) LEG OF ANGLE (2 MIN ON OPPOSITE SIDE OF UNIT) 3/8" STRUCT 1 SHEATING #10 SMS @ 4" OC MAX AROUND PERIMETER #10 SMS @ 12" OC MAX (TYP.) 800T 150-43 TRACK AT PAD PERIMETER (TYP.) (USE (1) #10 SMS EA FLANGE TO TRACK AT PERPENDICULAR TRACK INTERSECTIONS.) #12 SMS @ 24" OC MAX INTO DECK HIGH FLUTES AROUND PERIMETER ( 4 SCREWS MIN EA SIDE) 600S 162-43 STUD BLOCKING AT EA UNIT ANGLE ANCHOR (L3X3X12GA CLIP EA END OF BLOCKING W/(3) #10 SMS EA LEG) 800S 162-43 STUD @ 16" OC (TYP.) (USE (1) #10 SMS EA FLANGE TO TRACK AT EA END OF STUD) UNIT WITH COIL TYPE "L" COPPER TUBING WITH WROUGHT COPPER FITTINGS. OPEN VENT TO ATMOSPHERE WITH PERFORATED (MINIMUM OF FOUR 1/8" HOLES) COPPER CAP. CAP SHALL BE REMOVABLE. TRAP DEPTH SHALL BE 3" MINIMUM OR 1" GREATER THAN THE TOTAL STATIC PRESSURE OF THE SUPPLY FAN (IN.WG.), WHICHEVER IS GREATER. DIELECTRIC UNION DRAIN PAN 1% SLOPE (MIN) MINIMUM 1" ABOVE FLOOD RIM OF DRAIN PAN. 2 14 5 6 3 7 8 GLOBE VALVE VALVE G.V. GVTO FS DIRT LEG STEAM TRAP GV GV GV 12" MIN. 18" MIN. LPR WATER IN & OUT GV GV GV GV GV G.V. NOTE: 1. FOR PIPE SIZES & CONTINUATION SEE DRAWINGS. 2. INSULATE PIPING & HEAT EXCHANGER PER SPECIFICATIONS. NOTE: AFTER STARTUP - REPLACE FINE MESH STRAINERS WITH 3/16" MESH S.S. STRAINERS. NOTE: 1. UNIT ANCHORAGE TO ISOLATORS PER ISOLATOR MFR. ISOLATOR CURB ANCHORAGE TO STRUCTURE PER STRUCTURAL ENGINEER (3/S7.0-1) 1/4" STEEL PLATE X 3"W X 6"L MINIMUM SPRING ISOLATED BASE RAIL AIR HANDLER CONCRETE FLOOR WITH 2-3/4" MINIMUM EMBEDMENT 1/2" HILTI HSLB AT 24" O.C. MINIMUM NOTES: REFER TO STRUCTURAL DRAWINGS FOR LOADING LIMITATIONS TO STRUCTURAL, GENERIC DETAILS, AND ANCHOR REQUIREMENTS. ALSO REFER TO STRUCTURAL DRAWINGS FOR MINIMUM SEISMIC REQUIREMENTS FOR CONFORMANCE WITH 2022 CBC. NEOPRENE WASHER/BUSHING UNDER STEEL WASHER NOTE: 1. ALL VAV BOXES SHALL BE SEISMICALLY BRACED 10" NOTES: 1. CONDENSATE PIPE TERMINATION SHALL BE LOCATED A MINIMUM OF 1" ABOVE THE FLOOD RIM OF AN APPROVED TRAPPED RECEPTOR, LANDSCAPING AREA OR OTHER LOCATION AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. 2. ALL INTERIOR CONDENSATE DRAIN PIPING ABOVE CEILINGS SHALL BE INSULATED. 3. PROVIDE PIPE SUPPORTS AS REQUIRED TO MAINTAIN MINIMUM 1% SLOPE. 4. INSTALL TRAP PARALLEL TO UNIT, IF POSSIBLE. 5. MINIMUM CONDENSATE PIPE SIZES SHALL BE PER THE FOLLOWING TABLE UNLESS LARGER SIZE IS SHOWN ON PLANS OR AS REQUIRED BY AUTHORITY HAVING JURISDICTION AND/OR LOCAL BUILDING CODE REQUIREMENTS. CAPACITY SIZE UP TO 20 TONS 3/4" 21 TO 40 TONS 1" I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 M4.0-3 MECHANICAL DETAILS REV # DESCRIPTION DATE #201 RFI 06.09.2025 #201 RFI MARK FIXTURE ROUGH-IN-SIZE FIXTURE UNIT DESCRIPTION/REMARKS TRAP S/W V CW HW WASTE WATER WC-1 WATER CLOSET (FLUSH VALVE) ACCESSIBLE INT 4" 2" 1 1/2" - 4 5 AMERICAN STANDARD "AFWALL MILLENIUM" #3351.101, 16 1/2"HT. WALL MOUNTED, TOP SPUD, VITREOUS CHINA, ELONGATED BOWL, FLUSH VALVE TOILET. JAY R SMITH #0211Y SINGLE ADJUSTABLE HEAVY DUTY WATER CLOSET CARRIER 750LB OR EQUAL. INSTALL IN COMPLIANCE WITH ADA REQUIREMENTS. AMTC #HSM-801-CT-11 1.1 GPF, TOUCHLESS, SENSOR OPERATED DIAPHRAGM VALVE, MANUAL OVERRIDE BUTTON, HIGH BACK PRESSURE VACUUM BREAKER, FOUR (4) "C" ALKALINE BATTERIES. FLUSHOMETER TO BE MINIMUM 1.5" BELOW ADA GRAB BAR. AMERICAN STANDARD #5901.100SS OPEN FRONT LESS COVER, SELF SUSTAINING, HEAVY DUTY TOILET SEAT. WC-2 WATER CLOSET (FLUSH VALVE) BACK TO BACK ACCESSIBLE AND NON-ACCESSIBLE INT 4" 2" 1 1/2" - 4 5 AMERICAN STANDARD "AFWALL MILLENIUM" #3351.101, BACK TO BACK 16-1/2" HEIGHT AND STANDARD HEIGHT. WALL MOUNTED, TOP SPUD, VITREOUS CHINA, ELONGATED BOWL, FLUSH VALVE TOILET. JAY R SMITH #0221Y DOUBLE ADJUSTABLE HEAVY DUTY WATER CLOSET CARRIER 750LB OR EQUAL. INSTALL IN COMPLIANCE WITH ADA REQUIREMENTS. AMTC #HSM-801-CT-11 1.1 GPF, TOUCHLESS, SENSOR OPERATED DIAPHRAGM VALVE, MANUAL OVERRIDE BUTTON, HIGH BACK PRESSURE VACUUM BREAKER, FOUR (4) "C" ALKALINE BATTERIES. FLUSHOMETER TO BE MINIMUM 1.5" BELOW ADA GRAB BAR. AMERICAN STANDARD #5901.100SS OPEN FRONT LESS COVER, SELF SUSTAINING, HEAVY DUTY TOILET SEAT. PPP #FVP-1VB FLUSH VALVE TAILPIECE TRAP PRIMER WITH VACUUM BREAKER, AS REQUIRED PER PLAN. REFER TO DETAIL 4/P3.0. WC-3 WATER CLOSET (FLUSH VALVE)INT 4" 2" 1 1/2" - 4 5 AMERICAN STANDARD "AFWALL MILLENIUM" #3351.101, STANDARD HEIGHT WALL MOUNTED, TOP SPUD, VITREOUS CHINA, ELONGATED BOWL, FLUSH VALVE TOILET. JAY R SMITH #0211Y SINGLE ADJUSTABLE HEAVY DUTY WATER CLOSET CARRIER 750LB OR EQUAL. AMTC #HSM-801-CT-11 1.1 GPF, TOUCHLESS, SENSOR OPERATED DIAPHRAGM VALVE, MANUAL OVERRIDE BUTTON, HIGH BACK PRESSURE VACUUM BREAKER, FOUR (4) "C" ALKALINE BATTERIES. AMERICAN STANDARD #5901.100SS OPEN FRONT LESS COVER, SELF SUSTAINING, HEAVY DUTY TOILET SEAT. WC-4 WATER CLOSET (FLUSH VALVE) BACK TO BACK INT 4" 2" 1 1/2" - 4 5 AMERICAN STANDARD "AFWALL MILLENIUM" #3351.101, BACK TO BACK STANDARD HEIGHT. WALL MOUNTED, TOP SPUD, VITREOUS CHINA, ELONGATED BOWL, FLUSH VALVE TOILET. JAY R SMITH #0221Y DOUBLE ADJUSTABLE HEAVY DUTY WATER CLOSET CARRIER 750LB OR EQUAL. AMTC #HSM-801-CT-11 1.1 GPF, TOUCHLESS, SENSOR OPERATED DIAPHRAGM VALVE, MANUAL OVERRIDE BUTTON, HIGH BACK PRESSURE VACUUM BREAKER, FOUR (4) "C" ALKALINE BATTERIES. AMERICAN STANDARD #5901.100SS OPEN FRONT LESS COVER, SELF SUSTAINING, HEAVY DUTY TOILET SEAT. WC-5 WATER CLOSET (FLUSH VALVE) BACK TO BACK WITH URINAL INT 4" 2" 1 1/2" - 4 5 AMERICAN STANDARD "AFWALL MILLENIUM" #3351.101, STANDARD HEIGHT WALL MOUNTED, TOP SPUD, VITREOUS CHINA, ELONGATED BOWL, FLUSH VALVE TOILET. JAY R SMITH #0209Y SINGLE ADJUSTABLE HEAVY DUTY WATER CLOSET CARRIER WITH 2" AUXILIARY NO-HUB URINAL (UR-3). AMTC #HSM-801-CT-11 1.1 GPF, TOUCHLESS, SENSOR OPERATED DIAPHRAGM VALVE, MANUAL OVERRIDE BUTTON, HIGH BACK PRESSURE VACUUM BREAKER, FOUR (4) "C" ALKALINE BATTERIES. AMERICAN STANDARD #5901.100SS OPEN FRONT LESS COVER, SELF SUSTAINING, HEAVY DUTY TOILET SEAT. WC-6 WATER CLOSET (FLUSH VALVE) (ACCESSIBLE) INT 4" 2" 1 1/2" - 4 5 AMERICAN STANDARD "AFWALL MILLENIUM" #3351.101, 16 1/2"HT. WALL MOUNTED, TOP SPUD, VITREOUS CHINA, ELONGATED BOWL, FLUSH VALVE TOILET. JAY R SMITH #0211Y SINGLE ADJUSTABLE HEAVY DUTY WATER CLOSET CARRIER 750LB OR EQUAL. INSTALL IN COMPLIANCE WITH ADA REQUIREMENTS. AMTC #MF-700-T11 EXPOSED MANUAL DIAPHRAGM FLUSHOMETER, 1.1 GPF, CHROME PLATED. FLUSHOMETER TO BE MINIMUM 1.5" BELOW ADA GRAB BAR. AMERICAN STANDARD #5901.100SS OPEN FRONT LESS COVER, SELF SUSTAINING, HEAVY DUTY TOILET SEAT. PPP #FVP-1VB FLUSH VALVE TAILPIECE TRAP PRIMER WITH VACUUM BREAKER, AS REQUIRED PER PLAN. REFER TO DETAIL 4/P3.0. WC-7 WATER CLOSET (FLUSH VALVE)INT 4" 2" 1 1/2" - 4 5 AMERICAN STANDARD "AFWALL MILLENIUM" #3351.101, STANDARD HEIGHT WALL MOUNTED, TOP SPUD, VITREOUS CHINA, ELONGATED BOWL, FLUSH VALVE TOILET. JAY R SMITH #0211Y SINGLE ADJUSTABLE HEAVY DUTY WATER CLOSET CARRIER 750LB OR EQUAL. AMTC #MF-700-T11 EXPOSED MANUAL DIAPHRAGM FLUSHOMETER, 1.1 GPF, CHROME PLATED. AMERICAN STANDARD #5901.100SS OPEN FRONT LESS COVER, SELF SUSTAINING, HEAVY DUTY TOILET SEAT. UR-1 URINAL (ACCESIBLE)2" 2" 2" 1-1/2" - 2 4 AMERICAN STANDARD "WASHBROOK" #6590.001, WASHDOWN, TOP SPUD, VITREOUS CHINA, WALL MOUNTED, COLOR:WHITE AMTC #HSM-801FG-CU-18 0.125 GPF, TOUCHLESS, SENSOR OPERATED VALVE, MANUAL OVERRIDE BUTTON, HIGH BACK PRESSURE VACUUM BREAKER, FOUR (4) "C" ALKALINE BATTERIES. PROGRAMMABLE SETTINGS ON TIMER MODE ALLOW FLUSHING ONCE EVERY 30 MINUTES, 1, 2, OR 3 HOURS. JAY R. SMITH FIXTURE CARRIER SUPPORT. INSTALL IN COMPLIANCE WITH ADA REQUIREMENTS. UR-2 URINAL 2" 2" 2" 1-1/2" - 2 4 AMERICAN STANDARD "WASHBROOK" #6590.001, WASHDOWN, TOP SPUD, VITREOUS CHINA, WALL MOUNTED, COLOR:WHITE AMTC #HSM-801FG-CU-18 0.125 GPF, TOUCHLESS, SENSOR OPERATED VALVE, MANUAL OVERRIDE BUTTON, HIGH BACK PRESSURE VACUUM BREAKER, FOUR (4) "C" ALKALINE BATTERIES. PROGRAMMABLE SETTINGS ON TIMER MODE ALLOW FLUSHING ONCE EVERY 30 MINUTES, 1, 2, OR 3 HOURS. JAY R. SMITH FIXTURE CARRIER SUPPORT. UR-3 URINAL (ACCESIBLE)2" 2" 2" 1-1/2" - 2 4 AMERICAN STANDARD "WASHBROOK" #6590.001, WASHDOWN, TOP SPUD, VITREOUS CHINA, WALL MOUNTED, COLOR:WHITE AMTC #HSM-801FG-CU-18 0.125 GPF, TOUCHLESS, SENSOR OPERATED VALVE, MANUAL OVERRIDE BUTTON, HIGH BACK PRESSURE VACUUM BREAKER, FOUR (4) "C" ALKALINE BATTERIES. PROGRAMMABLE SETTINGS ON TIMER MODE ALLOW FLUSHING ONCE EVERY 30 MINUTES, 1, 2, OR 3 HOURS. JAY R. SMITH FIXTURE CARRIER SUPPORT. INSTALL IN COMPLIANCE WITH ADA REQUIREMENTS. CONNECT WITH WC-5. MARK FIXTURE ROUGH-IN-SIZE FIXTURE UNIT DESCRIPTION/REMARKS TRAP S/W V CW HW WASTE WATER LV-1 LAVATORY ONE STATION (UNDERMOUNT) ACCESSIBLE 1 1/2" 2" 2" 1/2" 1/2" 1 1 SLOAN DSG-81000 INTEGRATED SINK SYSTEM, ONE STATION CORIAN,WALL HUNG LAVATORY. COLOR: WHITE. MCGUIRE CHROME PLATED 17 GA. CAST BRASS LA PATTERN P-TRAP, SLIP JOINT NUTS AND CHROME PLATED BRASS SECURED ESCUTCHEON AND CLEANOUT PLUG. SLOAN ETF-420-LG-CP-0.35GPM-MLM-BAA-FCT FAUCET 0.35 GPM, 6VDC PLUG-IN ADAPTOR, CHICAGO FAUCET 1013-ABCP STOPS AND SUPPLIES, PROVIDE WITH TMV-1. SLOAN ESD-420-CP SOAP DISPENSOR, 4 "D" ALKALINE BATTERIES, 6VDC PLUG-IN ADAPTOR #ESD-324 (PN 0346090) SOAP DISPENSER ADAPTOR PLUG-IN CONNECTS TO MAX TWO (2) SOAP DISPENSERS. MCGUIRE PRE-MOLDED PVC COVERING HW & CW SUPPLIES & P-TRAP SHALL BE WRAPPED FOR HANDICAP PROTECTION. GROHE MOUNTING KIT. INSTALL IN COMPLIANCE WITH ADA REQUIREMENTS. LV-2 LAVATORY TWO STATION (UNDERMOUNT) ACCESSIBLE 1 1/2" 2" 2" 1/2" 1/2" 1 1 SLOAN DSG-82000 INTEGRATED SINK SYSTEM, TWO STATION CORIAN,WALL HUNG LAVATORY. COLOR: WHITE. MCGUIRE CHROME PLATED 17 GA. CAST BRASS LA PATTERN P-TRAP, SLIP JOINT NUTS AND CHROME PLATED BRASS SECURED ESCUTCHEON AND CLEANOUT PLUG. SLOAN ETF-420-LG-CP-0.35GPM-MLM-BAA-FCT FAUCET 0.35 GPM, 6VDC PLUG-IN ADAPTOR, CHICAGO FAUCET 1013-ABCP STOPS AND SUPPLIES, PROVIDE WITH TMV-1. SLOAN ESD-420-CP SOAP DISPENSOR, 4 "D" ALKALINE BATTERIES, 6VDC PLUG-IN ADAPTOR #ESD-324 (PN 0346090) SOAP DISPENSER ADAPTOR PLUG-IN CONNECTS TO MAX TWO (2) SOAP DISPENSERS. MCGUIRE PRE-MOLDED PVC COVERING HW & CW SUPPLIES & P-TRAP SHALL BE WRAPPED FOR HANDICAP PROTECTION. GROHE MOUNTING KIT. INSTALL IN COMPLIANCE WITH ADA REQUIREMENTS. LV-3 LAVATORY THREE STATION (UNDERMOUNT) ACCESSIBLE 1 1/2" 2" 2" 1/2" 1/2" 1 1 SLOAN DSG-83000 INTEGRATED SINK SYSTEM, THREE STATION CORIAN,WALL HUNG LAVATORY. COLOR: WHITE. MCGUIRE CHROME PLATED 17 GA. CAST BRASS LA PATTERN P-TRAP, SLIP JOINT NUTS AND CHROME PLATED BRASS SECURED ESCUTCHEON AND CLEANOUT PLUG. SLOAN ETF-420-LG-CP-0.35GPM-MLM-BAA-FCT FAUCET 0.35 GPM, 6VDC PLUG-IN ADAPTOR, CHICAGO FAUCET 1013-ABCP STOPS AND SUPPLIES, PROVIDE WITH TMV-1. SLOAN ESD-420-CP SOAP DISPENSOR, 4 "D" ALKALINE BATTERIES, 6VDC PLUG-IN ADAPTOR #ESD-324 (PN 0346090) SOAP DISPENSER ADAPTOR PLUG-IN CONNECTS TO MAX TWO (2) SOAP DISPENSERS. MCGUIRE PRE-MOLDED PVC COVERING HW & CW SUPPLIES & P-TRAP SHALL BE WRAPPED FOR HANDICAP PROTECTION. GROHE MOUNTING KIT. INSTALL IN COMPLIANCE WITH ADA REQUIREMENTS. LV-4 LAVATORY (WALL MOUNT) ACCESSIBLE 1 1/2" 2" 2" 1/2" 1/2" 1 1 AMERICAN STANDARD "DECORUM" #9024.904EC, 20" X 18-1/4" X 5" DEEP, WALL HUNG LAVATORY. THREE HOLE 4" CENTERS, LESS OVERFLOW, VIRTREOUS CHINA COLOR: WHITE. MCGUIRE CHROME PLATED 17 GA. CAST BRASS LA PATTERN P-TRAP, SLIP JOINT NUTS AND CHROME PLATED BRASS SECURED ESCUTCHEON AND CLEANOUT PLUG. SLOAN ETF-420-LG-CP-0.35GPM-MLM-BAA-FCT FAUCET 0.35 GPM, 6VDC PLUG-IN ADAPTOR, CHICAGO FAUCET 1013-ABCP STOPS AND SUPPLIES, PROVIDE WITH TMV-1. SLOAN ESD-420-CP SOAP DISPENSOR, 4 "D" ALKALINE BATTERIES, 6VDC PLUG-IN ADAPTOR #ESD-324 (PN 0346090) SOAP DISPENSER ADAPTOR PLUG-IN CONNECTS TO MAX TWO (2) SOAP DISPENSERS. MCGUIRE PRE-MOLDED PVC COVERING HW & CW SUPPLIES & P-TRAP SHALL BE WRAPPED FOR HANDICAP PROTECTION. GROHE MOUNTING KIT. INSTALL IN COMPLIANCE WITH ADA REQUIREMENTS. KS-1 KITCHEN SINK (SINGLE COMPARTMENT) 2" 2" 1-1/2" 1/2" 1/2" 2 2 ELKAY #ELUHAD211545 18-1/4" X 23-1/2" X 4-3/8" DEEP SINGLE COMPARTMENT UNDERMOUNTSINK ADA SINK, 18 GAUGE TYPE 300 STAINLESS STEEL. MCGUIRE CHROME PLATED 17 GA. CAST BRASS P-TRAP, SLIP JOINT NUTS AND CHROME PLATED BRASS SECURED ESCUTCHEON AND CLEANOUT PLUG. GROHE "MINTA" #30300000, 1.75 GPM, SINGLE HOLE PULL-DOWN, SINGLE HANDLE, SWIVEL SPOUT, 1.5 GPM COUPLING GROHE #64-999-000 COLOR: SUPERSTEEL INFINITY. ADA COMPLIANT. IN-SINK-ERATOR PRO 750 EVOLUTION SERIES. 120V, 15 AMPS, 60Hz, 3/4 HP. WITH WALL SWITCH. KS-2 KITCHEN SINK (DOUBLE COMPARTMENT) 2" 2" 1-1/2" 1/2" 1/2" 2 2 ELKAY #ECTSRAD33226TBG 33" X 22" X 6" DEEP DOUBLE COMPARTMENT UNDERMOUNTSINK ADA SINK, 18 GAUGE TYPE 300 STAINLESS STEEL. MCGUIRE CHROME PLATED 17 GA. CAST BRASS P-TRAP, SLIP JOINT NUTS AND CHROME PLATED BRASS SECURED ESCUTCHEON AND CLEANOUT PLUG. GROHE "MINTA" #30300000, 1.75 GPM, SINGLE HOLE PULL-DOWN, SINGLE HANDLE, SWIVEL SPOUT, 1.5 GPM COUPLING GROHE #64-999-000 COLOR: SUPERSTEEL INFINITY. ADA COMPLIANT. IN-SINK-ERATOR PRO 750 EVOLUTION SERIES. 120V, 15 AMPS, 60Hz, 3/4 HP. WITH WALL SWITCH. S-1 MAKER STORAGE SINK (SINGLE COMPARTMENT) 2" 2" 1-1/2" 1/2" 1/2" 2 2 ELKAY #ELUHAD211545 18-1/4" X 23-1/2" X 4-3/8" DEEP SINGLE COMPARTMENT UNDERMOUNTSINK ADA SINK, 18 GAUGE TYPE 300 STAINLESS STEEL. MCGUIRE CHROME PLATED 17 GA. CAST BRASS P-TRAP, SLIP JOINT NUTS AND CHROME PLATED BRASS SECURED ESCUTCHEON AND CLEANOUT PLUG. GROHE "MINTA" #30300000, 1.75 GPM, SINGLE HOLE PULL-DOWN, SINGLE HANDLE, SWIVEL SPOUT, 1.5 GPM COUPLING GROHE #64-999-000 COLOR: SUPERSTEEL INFINITY. ADA COMPLIANT. DF-1 ELECTRIC WATER COOLER (BI-LEVEL) (BOTTLE FILL) 1-1/4" 2" 2" 1/2" - 1 1 MURDOCK #A171.8-FGVR-BF12-CSC3-WF1 SINGLE DRINKING FOUNTAIN WITH BOTTLE FILL,RECESSED WALL MOUNTED, SATIN STAINLESS STEEL, BARRIER FREE, 8 GPH @50 DEG. F. WATER WITH 80 DEG. F. INLET WATER AT 90 DEG. F. AMBIENT. 1/5 HP, 115 VOLT, 1 PHASE COMPLETE W/ CONCEALED MOUNTING FRAME AND 1 MICRON FILTER. CHICAGO #45LK STRAIGHT ANGLE STOP W/ 1/2" FEMALE INLET/OUTLET. MS-1 MOP SINK 3" 3" 2" 1/2" 1/2" 3 3 ADVANCE TABCO #9-OP-20 FLOOR MOUNTED MOP SINK, 16 GAUGE TYPE "304" STAINLESS STEEL. 21" X 25" X 10". #K-16 FREE FLOW DRAIN AMERICAN STANDARD #8350.243 EXPOSED YOKE WALL MOUNT UTILITY FAUCET, 3" CAST BRASS SPOUT WITH VACUUM BREAKER, INTEGRAL STOPS, 8" CENTERS, LEVER HANDLES, BUCKET HOOK, 3/4" THREADED HOSE END. RB-1 REFRIGERATOR BOX - - - 1/2" - - .5 SIOUX CHIEF #696G1010PF, ICE MAKER OUTLET BOX WITH WATER HAMMER ARRESTOR FD-1 FLOOR DRAIN 2" 2" 2" 1/2" TP - - -JAY R SMITH #2005YB-B-P050 CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE, WEEPHOLES, HEAVY DUTY WITH POLISHED STAINLESS STEEL STRAINER WITH TRAP PRIMER CONNECTION. FS-1 FLOOR SINK 2" 2" 2" 1/2" TP - - -JAY R SMITH 3100Y-C-12, 10" X 10" X 6" DEEP, SANI-CEPTOR ACID RESISTANT COATED FLOOR SINK, WITH SEEPAGE HOLES, NICKEL BRONZE RIM 1/2 GRATE. TMV-1 THERMOSTATIC MIXING VALVE - - - 1/2" 1/2" - -APOLLO VALVE 34DLF-402-B17 #MVDBR-LF. SET TEMPERATURE TO 100 DEG. F. ASSE 1070 COMPLIANT. MOUNT BELOW FIXTURE. TMV-1 MASTER MIXING VALVE - - - 1-1/4" 1-1/4" - -APOLLO VALVE MASTER MIXING VALVE. SET TEMPERATURE TO 120 DEG. F. MOUNT AT HEAT PUMP WATER HEATER FCO-1 FLOOR CLEANOUT -SEE PLANS - - - - -JAY R SMITH #4040-U SERIES SQUARE TOP FLOOR CLEANOUT WITH VANDAL PROOF TOP. WCO-1 WALL CLEANOUT -SEE PLANS - - - - -JAY R SMITH #4420 SERIES CLEANOUT WITH FACE OF WALL COVER. TP-1 TRAP PRIMER - - - 1/2" - - -JAY R. SMITH #2694 TRAP DEFENDER, PRESSURE DROP ACTIVATED TRAP PRIMER WITH ACCESS PANEL. BRASS BODY. WITH DISTRIBUTION UNIT. SHUT-OFF VALVE TO BE UPSTREAM OF TRAP PRIMER WHA-1 HAMMER ARRESTOR - - - - - - -JAY R SMITH #5200 SERIES HYDROTROL JUNIIOR PISTON TYPE WATER HAMMER ARRESTOR. INSTALL PER MANUFACTURERS RECOMMENDATION CALGREEN TABLE A5.303.2.3.1 FIXTURE TYPE BASELINE FLOW RATE SHOWERS HEADS 1.8 GPM @ 60 PSI LAVATORY FAUCETS NON RESIDENTIAL 0.5 GPM @ 80 PSI WASH FOUNTAINS 1.8 GALLONS / CYCLE / 20 [RIM SPACE (IN) @ 60 PSI] METERING FOUNTAINS 0.20 GALLONS / CYCLE METERING FOUNTAINS FOR WASH FOUNTAINS 0.20 GALLONS / CYCLE / 20 [RIM SPACE (IN) @ 60 PSI] GRAVITY TANK TYPE WATER CLOSETS 1.28 GALLONS / FLUSH FLUSHOMETER TANK WATER CLOSETS 1.28 GALLONS / FLUSH FLUSHOMETER VALVE WATER CLOSETS 1.28 GALLONS / FLUSH ELECTROMECHANICAL HYDRAULIC WATER CLOSETS 1.28 GALLONS / FLUSH URINALS 0.125 GALLONS / FLUSH 1. INCLUDES WATER CLOSETS WITH AN EFFECTIVE FLUSH RATE OF 1.12 GALS OR LESS WHEN TESTED PER ASME A 112.19.2 AND ASME A 112.19.14 2. SEE CALGREEN TABLE A5.503.2.2 FOR ADDITIONAL NOTES AND REFERENCES. 3. WHERE COMPLYING FAUCETS ARE UNAVAILABLE, AERATORS RATED AT 0.35 GPM OR OTHER MEANS MAY BE USED TO ACHIEVE REDUCTION. 4. WALL MOUNTED URINALS @ 0.125 GPF. PLUMBING FIXTURE SCHEDULE PLUMBING FIXTURE SCHEDULE WATER REDUCTION FIXTURE FLOW RATE PIPE MATERIAL SCHEDULE SERVICE LOCATION MATERIALS SANITARY WASTE AND VENT ABOVE GRADE SOLID WALL PVC SCH. 40 ASTM D2665 DWV WITH PVC SOCKET FITTINGS. ASTM D2665 IN ACCORDANCE WITH ASTM D3311 DWV PATTERNS TO FIT SCH. 40 PIPE. ADHESIVE PRIMER ASTM F656 SOLVENT CEMENT ASTM D2564 SANITARY WASTE BELOW GRADE HARD DRAWN COPPER TYPE "L" ASTM B88. PERMANENTLY COLOR MARKED WITH MANUFACTURER'S TRADEMARK AND COUNTRY OF ORIGIN. TYPE "L" SHALL BE MARKED IN BLUE. COPPER PRESSURE SEAL JOINT FITTINGS, EPDM O-RINGS AND PIPE STOPS. MINIMUM 200 PSIG WORKING PRESSURE RATING AT 250 DEG. F. DOMESTIC WATER WATER HEATER PIPING NEWAGE EPOXY COATED HUBLESS, CAST IRON SOIL PIPE AND FITTING SERVICE CLASS, ASTM A888 AND CISPI 301. MIN. 4 BAND NEWAGE EXTRA HEAVY DUTY COUPLINGS, ASTM C 1540, ASTM C564, IAPMO LISTED. I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 P0.1-1 PLUMBING SCHEDULES RFI REV # DESCRIPTION DATE RFI 51 #008 ASI 04.11.2025 #008 ASI 2 2 3 3 EE FF STAFF BREAK ROOM 004 WC-6 LV-1 TMV-1 MS-1 HPWH-1 ET-1 CP-1 KS-1 3/4"HW UP3/4"HW UP (LV) 2"FD-1 3/ 4 " ø C W 3/ 4 " ø H W 1/ 2 " ø H W R 1/ 2 " ø H W R RB-1 (LV) LV-1 TMV-1 2"FD-1 WC-6 (S) 3/4"HW AND CW UP 1 1/2"ø CW 2"ø CW 1"ø CW 3/4"ø HW 3/ 4 " ø H W 1" ø H W 1/2"ø CW 1/ 2 " ø C W 3/ 4 " ø H W 2 2 3 3 EE FF ALL GENDER RESTROOM 010 STAFF BREAK ROOM 004 SE-1 SE-2 WC-4 WC-4 LV-1 3"MS-1 WCO 2"FD-1 2"FD-1 WCO WCO KS-1 WCO (WC) (FD) (UR) (LV)(LV) (FD) 4" ø W 4"ø W 4"ø W 2" ø W 2"ø W 2"ø W 4"ø W 2"ø W 2"ø W 2"ø W 2"ø W 2" ø W 3/4"ø CD 3/ 4 " ø C D WCO 2"ø V (E)4"W 3/4"ø CD 3/ 4 " ø C D FANCOIL SEE MECH PLANS 2" ø W 2"ø W 4"ø W4" ø W 2"ø W 3"ø W 3" ø W 2" FORCE PIPING (S) 2" ø W 3"V FROM BASIN 2"ø W 2"ø V 3"V UP PIT CONTROL PANEL 2" ø V 7 7 8 8 9 9 FF HH WOMEN RR 111 MEN RR 110 ALL GENDER RESTROOM 115 ALL GENDER RESTROOM 114 NURSING/SENSORY 116 JAN. RM 112 2" ø W WC-3 WC-2WC-1 WC-3 WC-4 WC-4 WC-5 WC-1 WC-4WC-4 UR-2 UR-2 UR-3 (E)MS DF-1 LV-3 TMV-1 LV-2 TMV-1 LV-4 LV-4 DF-1 2"ø V 2"ø V 2"ø V 2"ø V 2"ø V 2"ø W (WC) (LV) (LV) (LV) (WC) (FS) 2"W DOWN 4"W DOWN 2" ø W (E)FS 2"ø W 2"ø V4"ø W 2"ø V2" ø V 2" ø V 2" ø V 7 7 8 8 9 9 FF HH WOMEN RR 111 MEN RR 110 ALL GENDER RESTROOM 115 ALL GENDER RESTROOM 114 NURSING/SENSORY 116 JAN. RM 112 3/ 4 " ø C W 3/ 4 " ø H W 3/ 4 " ø C W 3/ 4 " ø H W 3/ 4 " ø C W WC-3 WC-2 WC-1 WC-3 WC-4 WC-4 WC-5 WC-1 WC-4WC-4 UR-2 UR-2 UR-3 (E)MS DF-1 LV-3 TMV-1 LV-2 TMV-1 LV-4 TMV-1 LV-4 TMV-1 DF-1 2"CW UP 2"CW UP 2"CW DOWN 1-1/4"CW UP 1-1/4"CW DOWN (LV)(LV) 2"CW HEADER2-1/2"CW DOWN 2"ø CW2"ø CW 3/ 4 " ø C W 3/ 4 " ø C W 2" ø C W 1"ø HW3/4"ø HW 1" ø H W 3/4"ø CW 1"ø HW 1 1 / 4 " ø H W 1 1 / 4 " ø H W 1" ø C W 3/ 4 " ø C W TP-1 3/4"ø CW BEH. A.P. I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. SHEET NOTES N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ELECTRICAL-PLMUMBING-MECHANICAL 1920 MAIN STREET, SUITE 820 IRVINE, CA92614 TEL: 949.516.6480 BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 P2.5-1 ENLARGED PLUMBING FLOOR PLAN RESTROOMS 1/4" = 1'-0"1 ENLARGED DOMESTIC WATER FLOOR PLAN RESTROOM BASEMENT 1/4" = 1'-0"2 ENLARGED SANITARY AND VENT FLOOR PLAN RESTROOM BASEMENT 1/4" = 1'-0"4 ENLARGED SANITARY AND VENT FLOOR PLAN RESTROOM FIRST FLOOR 1/4" = 1'-0"3 ENLARGED DOMESTIC WATER FLOOR PLAN RESTROOM FIRST FLOOR 096 RFI 096 RFI REV # DESCRIPTION DATE #020 ASI 03.21.2025 096 RFI 03.27.2025 #177 RFI 05.21.2025 #177 RFI #177 RFI RO S S S T R E E T LI M I T O F W O R K LIMIT OF WORK SANTA ANA LIBRARY LIMIT OF WORK LIMIT OF WORK PA R K I N G S T R U C T U R E LI M I T O F W O R K KID'S AREA N.A.P. T R TR EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL TR EXISTING TO REMAIN Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z LI M I T O F W O R K LIMIT OF WORK SANTA ANA LIBRARY LIMIT OF WORK LIMIT OF WORK PA R K I N G S T R U C T U R E LI M I T O F W O R K KID'S AREA N.A.P. 7'-4"7'-4"7'-4"7'-4" T R TR EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL TR EXISTING TO REMAIN terra n I N T E G R A T I O N Landscape Architecture CA#5231 Planning + Design + Sustainability 143 S. Olive St. Orange I CA I 92866 714-724-9814 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 REV #DESCRIPTION DATE #9 RFI 10.23.2024 BID SET 04/30/2024 FINAL PERMIT/ CONFORM SET 08/02/2024 #19 RFI 3.28.2025 #20 RFI 3.28.2025 #57.1 RFI 6.18.2025 CONSTRUCTION PLAN LA-2.0 NORTH 0 10'20'40' SCALE: 1" = 20'-0" PA PA PA PA PA PA CONSTRUCTION LEGEND SYMBOL DESCRIPTION DETAIL MANUFACTURER MATERIAL/ MODEL COLOR/ FINISH NOTES LANDSCAPE SHADE STRUCTURE B/ LA-2.2 PRISMATIC POWDER COAT POST: WHITE COLOR & FINISH TO MATCH EAST GARDEN PORTHOLE ON ARCHITECTURE TRELLIS: CINDERBLOCK BROWN COLOR SEE STRUCTURAL ENGINEERING PLANS FOR CONSTRUCTION COLOR SAMPLES TO BE PROVIDED BY FABRICATOR CONCRETE AMPHITHEATER SEATING B/ LA-2.2 DAVIS CONCRETE DAYTON SUPERIOR COLOR: PEBBLE FINISH: TOP CAST #1 COMPOSITE WOOD DECK D,E,F/LA-2.1 CALI BAMBOO 888-788-2254 SEDONA TRUORGANICS 3G WIDE COMPOSITE WWW.CALIBAMBOO.COM PROVIDE SAMPLES FOR APPROVAL PAVING CONCRETE FLATWORK - VEHICULAR SEE CIVIL PLANS DAVIS CONCRETE DAYTON SUPERIOR PIP CONCRETE COLOR: PEBBLE FINISH: TOPCAST #1 & SEEDED 10MM DARK-COLORED COARSE AGGREGATE SAMPLES TO BE PROVIDED FOR APPROVAL CONCRETE FLATWORK SEE CIVIL PLANS DAVIS CONCRETE DAYTON SUPERIOR PIP CONCRETE COLOR: PEBBLE FINISH: TOPCAST #1 COLORED CONCRETE - VEHICULAR SEE CIVIL PLANS DAVIS CONCRETE DAYTON SUPERIOR PIP CONCRETE COLOR: PEBBLE FINISH: TOPCAST #1 COLORED CONCRETE SEE CIVIL PLANS DAVIS CONCRETE DAYTON SUPERIOR PIP CONCRETE COLOR: PEBBLE FINISH: TOPCAST #1 & SEEDED 10MM DARK-COLORED COARSE AGGREGATE SAMPLES TO BE PROVIDED FOR APPROVAL 18" WIDE CONCRETE BAND - VEHICULAR B/ LA-2.1 PIP CONCRETE NATURAL GRAY CONCRETE / BROOM FINISH 12" WIDE CONCRETE BAND B/ LA-2.1 PIP CONCRETE NATURAL GRAY CONCRETE / BROOM FINISH 6" WIDE CONCRETE HEADER C/ LA-2.1 PIP CONCRETE NATURAL GRAY CONCRETE / BROOM FINISH COBBLE C/ LA-2.1 1" - 3" SMOOTH PEBBLE COLOR: GRAY TONES SAMPLES TO BE PROVIDED FOR APPROVAL. 4" MIN DEPTH. CONCRETE STEPS I/ LA-2.1 DAVIS CONCRETE DAYTON SUPERIOR PIP CONCRETE COLOR: PEBBLE FINISH: TOPCAST #1 PERMEABLE PAVERS F/ LA-2.2 STEPSTONE, INC. 3X18X4 NARROW MODULAR PAVERS WITH 1/8" T-BARS FOR PERMEABILITY COLOR: ALMOND FINISH: 1806 LIGHT SANDBLAST SAMPLES TO BE PROVIDED FOR APPROVAL 6" BAND AT PAVER EDGE F/ LA-2.2 DAVIS CONCRETE DAYTON SUPERIOR PIP CONCRETE COLOR: PEBBLE FINISH: TOPCAST #1 WALLS SEATWALL D/ LA-2.1 DAVIS CONCRETE DAYTON SUPERIOR COLOR: PEBBLE FINISH: TOPCAST #1 PLANTER WALL F/ LA-2.1 DAVIS CONCRETE DAYTON SUPERIOR VALORI PRECAST COLOR: PEBBLE FINISH: TOPCAST #1 CAP: 3" SQUARE, GRIS SANDBLAST SAMPLES TO BE PROVIDED FOR APPROVAL FENCING / GATES 8' HT. FENCING A/ LA-2.2 PRISMATIC POWDER COAT TUBULAR STEEL CINDERBLOCK BROWN SHOP DRAWINGS TO BE SUBMITTED FOR APPROVAL PEDESTRIAN GATE - SINGLE C/ LA-2.2 PRISMATIC POWDER COAT TUBULAR STEEL CINDERBLOCK BROWN SHOP DRAWINGS TO BE SUBMITTED FOR APPROVAL PEDESTRIAN GATE - DOUBLE D/ LA-2.2 PRISMATIC POWDER COAT TUBULAR STEEL CINDERBLOCK BROWN SHOP DRAWINGS TO BE SUBMITTED FOR APPROVAL L-1 L-2 L-3 P-1 P-2 P-3 P-4 P-5 P-6 P-7 P-8 P-9 P-10 P-11 W-1 W-2 F-1 F-2 F-3 REFERENCE LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION TRASH ENCLOSURE PER ARCHITECT MODULAR WETLAND SYSTEM BY CIVIL ENGINEER DRIVEWAY APRON PER CIVIL ENGINEER DETECTABLE WARNING PER CIVIL ENGINEER CURB PER CIVIL ENGINEER LIGHT POLE STANDARDS PER LIGHTING CONSULTANT CURB RAMP BY CIVIL ENGINEER SOUTH TRELLIS BY ARCHITECT CONCRETE PARKING LOT BY CIVIL ENGINEER EXPANSION JOINTS - SEE LA-2.1 FOR DETAIL NEW LIBRARY MONUMENT SIGN BY SIGNAGE CONSULTANT 1 7 2 8 3 9 4 10 5 11 6 NOTES 1.CONTRACTOR TO CONTACT LANDSCAPE ARCHITECT AND/OR OWNER IF ANY DISCREPANCIES BETWEEN LEGEND AND PLAN AND/OR PLANS AND SITE OCCUR. 2.EXISTING SECURITY LIGHT POLES TO BE REMOVED. 3.EXISTING PLAQUES AND TIME CAPSULE TO BE RELOCATED PER PLAN, SEE CALL OUT S-3 4.CONTRACTOR TO COORDINATE EXACT LOCATIONS OF CONCRETE DRIVE ISLE EXPANSION JOINTS WITH FUTURE STEAM UTILITY PLANS. CIVIC CENTER DRIVE PA PA PA PA PA TURF PAPA PA PA PA PA PA PA PA PA PA (2) EXISTING LIGHT STANDARDS TO REMAIN- PROTECT IN PLACE EXISTING CONCRETE SIDEWALK TO REMAIN, PROTECT IN PLACE EXISTING CONCRETE SIDEWALK TO REMAIN, PROTECT IN PLACE L-2 L-3 W-2 LI M I T O F W O R K F-1 S-1 P-2 P-2 P-3 1 2 3 3 3 4 4 5 PA 6 EXISTING STATUE TO REMAIN, PROTECT IN PLACE P-7 P-2 P-9 P-7 P-8 EXISTING FICUS, PROTECT IN PLACE. NOT IN SCOPE - SHOWN FOR ADDITIONAL INFORMATION EXISTING PILASTERS TO REMAIN, PROTECT IN PLACE P-2 7 W-2 PA 19'-9" 5'-0" 24'-0" 9' - 0 " 3' - 0 " 1'-9" 1' - 8 " 6'-9" 1' - 6 " AL I G N 9'-7" 2'-0"15'-0" 11'-6" 10'-9" CONTRACTOR TO COORDINATE TRANSITIONS BETWEEN NEW & EXISTING ELEMENTS IN THIS LOCATION W/ DESIGN TEAM PRIOR TO INSTALLATION C LA-2.2 B LA-2.2 9'-10" 47'-9" R10 ' - 6 " 9'-10" 8 8 PA CONCRETE HEADER SHALL BE CLEAR OF CENTER OF TREE TRUNK BY 6'-0" MIN. TYPICAL FOR BOTH 5' - 0 " 5' - 0 " 8' - 0 " 3'-0" W-1 F-1 P-8 F-2 F-3 F-1 P-2 P-2P-2 S-3 S-6 S-8 P-4 P-2 P-4 P-2 2'-2" 11 ' - 6 " 6' - 0 " 6'-0" 3'-0" 13'-7" 8'-7"8'-0"12'-7" 12 ' - 0 " 10 ' - 0 " 17 ' - 0 " 3'-0" AL I G N Ø3 5 ' - 0 " 4' - 0 " EXISTING FICUS, PROTECT IN PLACE. NOT IN SCOPE - SHOWN FOR ADDITIONAL INFORMATION ADA COMPANION SEATING AT AMPHITHEATER BENCH P-5 CONTRACTOR TO REMOVE BACKFLOW, MASTER VALVE, AND FLOW SENSOR. HALF OF EXISTING PLANTER TO BE CONCRETE FILLED. WHERE NEW CONCRETE IS REQUIRED, EXTEND EXISTING COLOR/ FINISH FROM ADJACENT PLAYGROUND AREA. PA P-6 TURF P-3 P-6 P-6 10 S-5 S-3 FLAGPOLE TO REMAIN. PROTECT IN PLACE S-3 L-1 P-2 S-4 S-4 3' - 0 " S-2 14'-7" CONSTRUCTION LEGEND cont'd SYMBOL DESCRIPTION DETAIL MANUFACTURER MATERIAL/ MODEL COLOR/ FINISH NOTES SITE AMENITIES BOOK DROP G/ LA-2.1 KINGSLEY LIBRARY EQUIPMENT 60 C-SERIES, 00-9860 LUSTER REFER TO MANUFACTURERS SPECIFICATIONS FOR INSTALLATION. DEPOSITARY OPENING TO BE STREET FACING FOR EASY CART REMOVAL PARKING METER PER CIVIL N/A N/A N/A PARKING METER PROVIDED BY CITY OF SANTA ANA PARKING METER OPERATIONS (CDA) RELOCATED LIBRARY TIME CAPSULE/ PLAQUE SEE CIVIL ENGINEER DEMOLITION PLAN C1.2-0 N/A N/A N/A N/A EXISTING PLAQUES AND TIME CAPSULE TO BE RELOCATED AND APPROVED BY LIBRARY PRIOR TO ANY HARDSCAPE POUR. CONTRACTOR SHALL SAFELY PACK AND COORDINATE TIME CAPSULE STORAGE LOCATION WITH LIBRARY UNTIL FINAL INSTALL. RECEPTACLE BINS N/A FORMS AND SURFACES APEX RECEPTACLE, 36-GALLON SPLIT-STREAM WITH RAIN COVER AND TOOL OPERATED SECURITY LATCH. INSET MATERIAL: STAINLESS STEEL IN SATIN FINISH LID, RAINCOVER, AND FRAME MATERIAL: ALUMINUM POWDERCOAT WHITE FINISH GRAPHIC: BLACK BACKGROUND, LITTER AND RECYCLING TOTAL QTY: 3, SURFACE MOUNT PLANTER POTS E/ LA-2.2 OLD TOWN FIBERGLASS PROTO - PCL3930FL WHITE, MATTE FINISH QTY 2 BIKE RACKS N/A STREETSCAPES.BIZ ARTISTIC BOOK BIKE RACK - READ - RBR-FT-PC DERO LIGHT GRAY RAL 7042 QTY 2, SURFACE MOUNT, INSTALL PER MANUFACTURERS RECOMMENDATIONS BOLLARDS N/A GRAINGER CBOL-42-4 STAINLESS STEEL QTY 2, SURFACE MOUNT CERAMIC PAVEMENT MARKERS N/A STOP-PAINTING.COM 6" ROUND CERAMIC ROAD REFLECTORS WHITE, NON-REFLECTIVE INSTALL PER MANUFACTURER'S RECOMMENDATION ENTRY POTTERY E/ LA-2.2 WAUSAUTILE.COM SL4034 CONCRETE PEDESTAL PLANTER PRIOR TO PURCHASE, VERIFY COLOR WITH LANDSCAPE ARCHITECT QTY: 2, SEE F / LA-3.3 FOR ENTRY POTTERY DETAIL S-1 S-2 S-3 S-4 S-5 S-6 S-7 S-8 S-9 L-3 9 S-2 P-2 Ø4'- 0 " 9'-7" 6'-0" 3'-0" P-10 P-10 P-6 11 P-6 P-3 11 11 S-4 P-11 11 P-11 S-7 P-1 P-5 ASI #19 ASI #19 ASI #20 P-2 P-6 ASI #20 ASI #20 ASI #20 S-9 ASI #20 ASI #20 RFI 57.1 RFI 57.1 terra n I N T E G R A T I O N Landscape Architecture CA#5231 Planning + Design + Sustainability 143 S. Olive St. Orange I CA I 92866 714-724-9814 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 REV #DESCRIPTION DATE #9 RFI 10.23.2024 BID SET 04/30/2024 FINAL PERMIT/ CONFORM SET 08/02/2024 #19 RFI 3.28.2025 #20 RFI 3.28.2025 #57.1 RFI 6.18.2025 CONSTRUCTION DETAILS LA-2.1 LEGEND 1.8 1/4"X7/8"X8' DECKING BOARD.3/16" EXPANSION SPACE BETWEEN BOARDS AND 1/4" EXPANSION SPACE ON ALL BUTT ENDS. 2.4x4 PRESSURE-TREATED JOIST. 3.8X8 CONCRETE FOOTING WITH Z-MAX STRAP 4.JOIST HANGER. BOLT TO CONCRETE CURB 5.CONCRETE CURB WITH #4 REBAR 6.ADJACENT CONCRETE SEAT WALL - PER STRUCTURAL ENGINEER 7.95% COMPACT SUB-GRADE PER CITY REQUEST 8.LANDSCAPE FABRIC UNDER DECK STAKED FOR WEED ABATEMENT 9.1"X4" PRESSURE-TREATED SLEEPER BOARD. MOUNT TO CONCRETE SLAB 10.CONCRETE SLAB 11.EXPANSION JOINT. SEE SEPARATE DETAIL NOTES A.CONTRACTOR SHALL FIELD VERIFY ALL EXISTING SITE CONDITIONS AND GRADES PRIOR TO FABRICATION. B.INSTALL PER MANUFACTURER RECOMMENDATIONS C.ALL WOOD IN CONTACT WITH CONCRETE AND/ OR EARTH SHALL BE TREATED WOOD. D.ALL INDENTATIONS ON ACCESSIBLE PATH OF TRAVEL SHALL NOT EXCEED 1/2" AND SHALL BE BEVELED IN 1/4" INCREMENTS. E.CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR LANDSCAPE ARCHITECT APPROVAL PRIOR TO CONSTRUCTION. F.ALL GRADES TO BE COORDINATED WITH CIVIL ENGINEER'S DRAWINGS 4'-0" O.C. CL CL 123 42 5 6 8 7 SECTION AT ROUND DECK PLAN VIEW N.T.S. FO O T I N G S : 4 ' O . C . 35' 4' PA PA PA PA PA JO I S T S : 4 ' O . C . HARDSCAPE HARDSCAPE PA 4'-0" O.C. CL CL 19 7 SECTION - DECKING ON CONCRETE SLAB (LINEAR) 10 ADJACENT CONCRETE CURB AT ROUND DECK 11 6" M I N . DECKING ON CONCRETE SLAB ROUND DECK LEGEND 1.CONCRETE BAND SEEDED 10MM DARK-COLORED COARSE AGGREGATE. 2.1/2" RADIUS 3.#4 REBAR 4.FINISHED SURFACE OF ADJACENT PAVING WHERE OCCURS 5.FINISHED GRADE OF ADJACENT LANDSCAPE WHERE OCCURS 6.95% COMPACT SUBGRADE PER CITY REQUEST 7.STAINLESS STEEL METAL DIVIDER STRIP (1 4" X 1") OR APPROVED EQUAL NOTES A.CONSTRUCT A HAND TOOLED JOINT EVERY 8' O.C. AND EXPANSION JOINT EVERY 24' O.C. B.ALL VEHICULAR BANDS SHALL BE COORDINATED AND VERIFIED WITH CIVIL ENGINEER SECTION 6" 12" OR 18" 2 1 45 6 2" F O R S H R U B S 1" F O R T U R F 3"CLR. 3 LEGEND 1.6" CONCRETE HEADER 2.1/4" RADIUS 3.FINISHED GRADE OF ADJACENT DECOMPOSED GRANITE WHERE OCCURS 4.FINISHED GRADE OF ADJACENT LANDSCAPE WHERE OCCURS 5.95% COMPACT SUB-GRADE PER CITY REQUEST 6.4" MIN. OF DECORATIVE COBBLE. 7.PATCHED SHAFT (WHERE OCCURS), PER STRUCTURAL ENGINEER 8.LANDSCAPE FILTER FABRIC 9.ADJACENT EXISTING ARCHITECTURE WALL NOTES A.CONSTRUCT A HAND TOOLED JOINT EVERY 6' O.C. AND EXPANSION JOINT EVERY 24' O.C. SECTION AT PLANTERS 6" 6" 2 1 3 5 2" A T S H R U B S 1" A T T U R F SECTION AT COBBLE 6 1 7 8 9 4" - 6 " 4 2" A T S H R U B S 1" A T T U R F 4 A B I F D E G H CONCRETE BAND - 12" OR 18" WIDE CONCRETE HEADER - 6" WIDE COMPOSITE WOOD DECKING SCALE: 1" = 1'-0" SCALE: 3/4" = 1'-0" SCALE: 1" = 1'-0" SCALE: 1/2" = 1'-0" SCALE: 1" = 1'-0"SCALE: NTS C SCALE: N.T.S. LEGEND 1.ADJACENT HARDSCAPE/ FINISH SURFACE - SEE CONSTRUCTION PLAN 2.CONCRETE STEPS 3.SAFETY GROOVES TO BE TROWELED WITHIN 1" OF STAIR TREAD EDGE 4.1/2" RADIUS, ALL STEPS 5.EXPANSION JOINT, SEE SEPARATE DETAIL NOTES A.REINFORCEMENT PER STRUCTURAL ENGINEER 1'-0" 1-1/2" 6" 1 2 3 4 5 CONCRETE STEPS LEGEND 1.CONCRETE FLATWORK - SEE SEPARATE DETAIL ON CIVIL ENGINEER'S PLANS 2.1/2" POLYETHLENE FOAM W/ 1/2" TEAR-AWAY STRIP. CAP WITH SELF-LEVELING JOINT SEALER. HAND SEED JOINTS WITH SAND 3.95% COMPACT SUB-GRADE PER CITY REQUEST 1 2 3 SECTION NOTES A.EXPANSION JOINTS ARE REQUIRED WHERE TWO OR MORE BUILDING OR STRUCTURAL ELEMENTS JOIN (I.E. WALL, COLUMN, THRESHOLD, STEPS, CURB, OR FENCE SLAT), OR TO SEPARATE LARGE SLABS OR DIFFERENT POURS. EXPANSION JOINTSEAT WALL AND DECKING SECTION 1'-6" 22'-0" +/-4'-0"6'-0" +/- 1' - 6 " LEGEND SECTION 221 3 1.8 1/4"X7/8"X8' COMPOSITE WOOD DECKING 2.4X4 PRESSURE TREATED JOIST 3.JOIST HANGER. BOLT INTO ADJACENT CONCRETE 4.#4 REBAR 5.8X8 FOOTING 6.CONCRETE CURB. INSTALL BELOW DECKING 7.PLANTER AREA DRAIN PER CIVIL ENGINEER 8.POURED IN PLACE SEAT WALL AND FOOTING. SEE STRUCTURAL ENGINEERING PLANS FOR FOOTING AND REINFORCEMENT 9.1" CHAMFER 10.TREE AND ROOTBALL PER PLANTING PLAN 11.FINISH GRADE 12.ELL BRACKET 13.95% COMPACT SUB-GRADE PER CITY REQUEST 14.LANDSCAPE FABRIC UNDER DECK STAKED IN PLACE FOR WEED ABATEMENT 6 2" MIN. NOTES A.INSTALL TREES PRIOR TO DECK JOISTS B.ALL GRADES TO BE COORDINATED WITH CIVIL ENGINEER'S DRAWINGS 5 7 8 11 9 3" MAX. 10 1" 4" 1' - 2 " 1/2"8" 2" 2" 4" 1' - 2 " F.G. 8" 1 1 2 2 3 6 6 8 6 3 F.G. 12 12 MOUNTING DETAILS N.T.S. 3 1313 4 4 4 14 LEGEND 1.ADJACENT PAVING 2.PRECAST CONCRETE CAP PER CONSTRUCTION LEGEND 3.RAISED PLANTER WALL AND FOOTING. REFER TO STRUCTURAL PLANS FOR FOOTING AND REINFORCEMENT 4.PLANTING BACKFILL MIX. REFER TO PLANTING SPECIFICATIONS 5.95% COMPACT SUBGRADE PER CITY REQUEST 6.COMPOSITE WOOD DECKING 7.4X4 SUPPORT FRAME JOIST - SEE SEPARATE DETAIL 8.8X8 FOOTING 9.FINISH GRADE 10.POURED IN PLACE SEATWALL AND FOOTING. SEE STRUCTURAL ENGINEERING PLANS FOR FOOTING AND REINFORCEMENT 11.CONCRETE CURB WITH #4 REBAR 12.LANDSCAPE FABRIC UNDER DECK STAKED IN PLACE FOR WEED ABATEMENT SECTION 2" 2" 1' - 4 " 2' - 0 " 876 1'-6"2"2" 1'-0" 2"2" 1'-0" 2"2" 1'-0" 2 1 3 45 7 10 91' - 6 " PER PLAN PER PLANPER PLAN 11 2' - 0 " 1' - 6 " 2 NOTES A.ALL GRADES TO BE COORDINATED WITH CIVIL ENGINEER'S DRAWINGS5 12 RAISED PLANTER AND DECKING SECTION SCALE: 1/2" = 1'-0" LEGEND 1.OUTDOOR DEPOSITORY. SEE CONSTRUCTION LEGEND FOR MANUFACTURER AND COLOR. INSTALL PER MANUFACTURER'S RECOMMENDATION 2.FINISH GRADE 3.VEHICULAR CONCRETE DRIVEWAY AND CURB (6"). REFER TO SEPARATE CIVIL ENGINEER'S PLANS FOR DETAIL 4.EXPANSION JOINT BETWEEN POURS. SEE SEPARATE DETAIL AND CONSTRUCTION PLAN 5.CERAMIC PAVEMENT MARKERS PER CIVIL ENGINEER. COLOR TO BE WHITE 6.FINISH SURFACE1 2 NOTES A.DEPOSITORY DOOR TO BE STREET FACING FOR EASY BOOK CART REMOVAL ST R E E T S I D E 3 6" MIN. 45 6 BOOK DROP PARKING METER - CITY OF SANTA ANA STANDARD DETAIL SCALE: 1/2" = 1'-0" RFI 57.1 SYMBOL MANUFACTURER/MODEL/DESCRIPTION ARC PSI GPM RADIUS RAIN BIRD RD-06-S-P30-F-U 08 HE-V TURF SPRAY, 6IN. POP-UP, WITH 30 PSI IN-STEM PRESSURE REGULATION, SEAL-A-MATIC CHECK VALVE, AND FLOW-SHIELD TECHNOLOGY. 1/2IN. NPT FEMALE THREADED INLET. ADJ 30 ≤ 1.19 8' RAIN BIRD RD-06-S-P30-F-U 12 HE-V TURF SPRAY, 6IN. POP-UP, WITH 30 PSI IN-STEM PRESSURE REGULATION, SEAL-A-MATIC CHECK VALVE, AND FLOW-SHIELD TECHNOLOGY. 1/2IN. NPT FEMALE THREADED INLET. ADJ 30 ≤ 2.38 12' RAIN BIRD RD-06-S-P30-F-U 15 HE-V TURF SPRAY, 6IN. POP-UP, WITH 30 PSI IN-STEM PRESSURE REGULATION, SEAL-A-MATIC CHECK VALVE, AND FLOW-SHIELD TECHNOLOGY. 1/2IN. NPT FEMALE THREADED INLET. ADJ 30 ≤ 3.71 15' RAIN BIRD 1806-1400 FLOOD 1401 FLOOD BUBBLER 6.0IN. POPUP 360 20 0.25 3' SYMBOL MANUFACTURER/MODEL/DESCRIPTION PIPE TRANSITION POINT PIPE TRANSITION POINT FROM PVC LATERAL TO DRIP TUBING WITH RISER TO ABOVE GRADE INSTALLATION. RAIN BIRD MDCFCAP DRIPLINE FLUSH VALVE CAP IN COMPRESSION FITTING COUPLER. RAIN BIRD ARV050 1/2IN. AIR RELIEF VALVE WITH A 6IN. DRIP VALVE BOX (SEB 7XB EMITTER BOX). USE WITH INSTALLATION BELOW SOIL. HUNTER SD-B-STK MICRO SPRAY FOR RESIDENTIAL/COMMERCIAL USE. EIGHT STREAMS OF WATER, WITH 360 DEGREE SPRAY. 15PSI TO 30PSI. SOLO-DRIP WITH BARB AND 6IN. STAKE. AREA TO RECEIVE DRIPLINE RAIN BIRD XFS-04-18 XFS SUB-SURFACE PRESSURE COMPENSATING DRIPLINE W/COPPER SHIELD TECHNOLOGY. 0.4 GPH EMITTERS AT 18" O.C. LATERALS SPACED AT 18" APART, WITH EMITTERS OFFSET FOR TRIANGULAR PATTERN. UV RESISTANT. SPECIFY XF INSERT FITTINGS. SYMBOL MANUFACTURER/MODEL/DESCRIPTION RAIN BIRD EFB-CP 1IN. BRASS REMOTE CONTROL VALVE, THAT IS CONTAMINATION PROOF W/SELF-FLUSHING FILTER SCREEN. GLOBE CONFIGURATION, RAIN BIRD EFB-CP-PRS-D 1IN. BRASS REMOTE CONTROL VALVE, THAT IS CONTAMINATION PROOF W/SELF-FLUSHING FILTER SCREEN. GLOBE CONFIGURATION. USE NIBCO T-113-K GATE VALVE BEFORE VALVE. ADD RAIN BIRD PRF-100-RBY FILTER WITH VALVE. HUNTER HQ-5LRC QUICK COUPLER VALVE, YELLOW LOCKING RUBBER COVER, RED BRASS AND STAINLESS STEEL, WITH 1IN. NPT INLET, 1-PIECE BODY. NIBCO T-113-K CLASS 125 BRONZE GATE SHUT OFF VALVE WITH CROSS HANDLE, SAME SIZE AS MAINLINE PIPE DIAMETER AT VALVE LOCATION. GRISWOLD 2160 1-1/2" 1IN.-8IN. SOLENOID, NORMALLY OPEN MASTER VALVE. CAST IRON AND BRONZE MATERIAL. NPT END CONNECTION. FEBCO LF850-U-S 2" REDUCED PRESSURE BACKFLOW ASSEMBLY CALSENSE CS3000-32-S/CS3-GR-KIT/TP-110 CS3000 SERIES 32 STATION AUTOMATIC CONTROLLER WITH STAINLESS STEEL TOP-ENTRY PEDESTAL ENCLOSURE AND 4G LTE CELLULAR MODEM WITH ANTENNA. FLOW METER TO BE INSTALLED, SEE SEPARATE CALLOUT. CONTRACTOR TO CONTACT CITY PUBLIC WORKS PRIOR TO PURCHASING TO VERIFY COMMUNICATIONS OPTIONS, EXISTING CALSENSE CELLULAR DATA PLAN, AND EXISTING INTEGRATION WITH PLAYGROUND. CALSENSE REP: DAVID MEEHAN (760) 580-1829 CALSENSE FM-1.5B 1.5" BRONZE FLOW METER IN 1" BRASS TEE. WIRE CONTROLLER USING #14 AWG WIRE IN 1" CONDUIT, INSTALL PER MANUFACTURERS RECOMMENDATIONS. MULTIPLE FLOW SENSORS REQUIRE SEPARATE CONDUIT RUNS. STRONG BOX SBBC-45CR LOW PROFILE, TUBE AND WIRE CONSTRUCTION SMOOTH TOUCH SURFACE, COLD ROLLED STEEL, BACKFLOW ENCLOSURE. 46.5IN.L, 28IN.H, 17.75IN.W. CALSENSE RB-1 TIPPING BUCKET RAIN SENSOR MOUNT TO BUILDING UNDER CITY AND HISTORICAL ARCHITECT REVIEW. WIRED PER MANUFACTURERS INSTRUCTIONS WATER METER 2" DOMESTIC WATER. SEE POINT OF CONNECTION NOTES. IRRIGATION LATERAL LINE: PVC SCHEDULE 40 SEE PIPE SIZING CHART IRRIGATION MAINLINE: PVC CLASS 315 SDR 13.5 PIPE SLEEVE: PVC SCHEDULE 40 8 21 51 NO SYMBOL 360 MV BF A FS BE RS M FLOW AVAILABLE Water Meter Size: Flow Available PRESSURE AVAILABLE Static Pressure at POC: Elevation Change: Service Line Size: Length of Service Line: Pressure Available: DESIGN ANALYSIS Maximum Station Flow: Flow Available at POC: Residual Flow Available: Critical Station: Design Pressure: Friction Loss: Fittings Loss: Elevation Loss: Loss through Valve: Pressure Req. at Critical Station: Loss for Fittings: Loss for Main Line: Loss for POC to Valve Elevation: Loss for Backflow: Loss for Master Valve: Loss for Water Meter: Critical Station Pressure at POC: Pressure Available: Residual Pressure Available: Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z CIVIC CENTER DRIVE RO S S S T R E E T LI M I T O F W O R K LIMIT OF WORK SANTA ANA LIBRARY LIMIT OF WORK LIMIT OF WORK PA R K I N G S T R U C T U R E LI M I T O F W O R K KID'S AREA N.A.P. T R TR EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL TR EXISTING TO REMAIN A 6.53A-4 1"Area for Dripline ZONE 10.4A-5 1"Area for Dripline ZONE 5.45 A-3 1"Area for Dripline ZONE 21 2121 51 51 21 21 21 2121 51 51 21 2121 21 21 21 21 21 51 51 51 51 51 21 2151 51 51 3 4" 3 4"1" 1" 3 4"3 4" 3 4" 114"3 4" 3 4" 1"3 4" 1"3 4" 3 4" 6A-6 1"Bubbler ZONE 1.91A-7 1"Area for Dripline ZONE 16.9A-8 1"Area for Dripline ZONE A-920.5 1"Turf Spray ZONE A-109.2 1"Turf Spray ZONE 10.4A-11 1"Turf Spray ZONE 20.7A-12 1"Turf Spray ZONE A-1310.7 1"Area for Dripline ZONE A-143.5 1"Bubbler ZONE 2" 2" BE 1" 1" A-17.36 1"Area for Dripline ZONE A-22 1"Bubbler ZONE 3 4" 51 51 21 21 21 21 21 21 21 21 21 21 51 888 8 8 3 4" 3 4"3 4" 3 4" M BF FS MV 3 4" 2" RS 11 4" 1" 11 4" 1" 114" 11 4" 1" 3 4" 114"11 4" 3 4"3 4" #" ## # VALVE CALLOUT VALVE NUMBER VALVE FLOW HYDROZONE VALVE SIZE terra n I N T E G R A T I O N Landscape Architecture CA#5231 Planning + Design + Sustainability 143 S. Olive St. Orange I CA I 92866 714-724-9814 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 REV #DESCRIPTION DATE #9 RFI 10.23.2024 BID SET 04/30/2024 FINAL PERMIT/ CONFORM SET 08/02/2024 #19 RFI 3.28.2025 #20 RFI 3.28.2025 #57.1 RFI 6.18.2025 IRRIGATION PLAN LA-3.0 1.POINT OF CONNECTION (POC) SHALL BE AT NEWLY PROVIDED 2" WATER METER AND SERVICE LINE. INSTALL NEW 2" BACKFLOW PREVENTOR, 1 1/2" MASTER VALVE, AND 1 1/2" FLOW METER AT LOCATION INDICATED ON CIVIC CENTER DRIVE. REFERENCE CIVIL ENGINEERING UTILITY PLANS FOR MORE INFORMATION 2.CONTRACTOR SHALL CAP EXISTING IRRIGATION TO SITE AND ABANDON CURRENT OPERATING EQUIPMENT. NEW IRRIGATION SHALL BE INSTALLED PER PLAN. 3.THE CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION AND WATER PRESSURE IN THE FIELD PRIOR TO STARTING WORK. THE DYNAMIC WATER PRESSURE SHALL BE MEASURED AT THE MAXIMUM SYSTEM DEMAND AS INDICATED BELOW. IF ANY OF THE POC INFORMATION SHOWN ON THESE DRAWINGS IS FOUND TO BE DIFFERENT THAN THE ACTUAL POC INFORMATION GATHERED IN THE FIELD, IMMEDIATELY NOTIFY THE LANDSCAPE ARCHITECT,SHOULD THE CONTRACTOR FAIL TO VERIFY THE POC INFORMATION AS SHOWN HEREIN, ANY CHANGES REQUIRED BY LOW PRESSURE OR VOLUME SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AT NO ADDITIONAL COST TO THE CITY/ OWNER. WATER PRESSURE AT METER 60-65 PSI DESIGN WATER PRESSURE 30 PSI 4.CONTROLLER NOTE: 4.1.THE CONTRACTOR SHALL REMOVE THE EXISTING IRRIGATION CONTROLLER, AND INSTALL NEW CALSENSE CONTROLLER PER IRRIGATION LEGEND. RE-ESTABLISH CONNECTION TO EXISTING POWER SUPPLY. CONNECT & INTEGRATE EXISTING PLAYGROUND STATIONS INTO NEW CONTROLLER. 1.CONTRACTOR TO INSTALL ALL IRRIGATION EQUIPMENT WITHIN LIMIT OF SITE WORK. SHOWN FOR CLARITY ONLY - IRRIGATION IS SCHEMATIC. 2.THE IRRIGATION PLAN IS DIAGRAMMATIC. CONTRACTOR CAN ROUTE PIPING IN A FREE FORM MANNER, AVOIDING OBJECTS LIKE LIGHT STANDARDS, TRANSFORMER PADS, EQUIPMENT VAULTS, SUB-SURFACE ROCK TOO LARGE TO REMOVE, ETC. DRIPLINE NOTES LATERAL PIPE SIZING FLOW PIPE SIZE FLOW PIPE SIZE 0-8 GPM 3/4"22.1-28 1 1/2" 8.1-12 GPM 1"28.1-45 2" 12.1-22 GPM 1 1/4"45.1+2 1/2" COMPLIANCE NOTE I HAVE COMPLIED WITH THE CRITERIA OF THE ORDINANCE AND APPLIED THEM FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLANS. 3/17/2022 LANDSCAPE ARCHITECT DATE POINT OF CONNECTION NOTES IRRIGATION LEGEND INSTALL BUBBLERS ON OUTER EDGE OF MULCH LINE. SEE PLANTING PLAN FOR MULCH LINE. WIRE SLEEVE: PVC SCHEDULE 40. BURY MIN. 24" BELOW GRADE, EXTEND MIN. 12" BEYOND EDGE. NO SYMBOL NORTH 0 10'20'40' SCALE: 1" = 20'-0" CONNECT NEW MAINLINE TO EXISTING MAINLINE SERVICING CHILDREN'S PLAYGROUND THROUGH SHUT OFF VALVE. SHUT OFF VALVE TO BE LOCATED IN EXISTING PLANTER AND TO RECEIVE 3" LAYER OF BARK MULCH PER PLANTING PLANS CONTRACTOR TO REMOVE EXISTING BACKFLOW, MASTER VALVE, AND FLOW SENSOR ONLY. EXISTING CHILDREN'S PLAYGROUND IRRIGATION TO BE INCORPORATED INTO NEW OVERALL LIBRARY IRRIGATION SYSTEM REFER TO CIVIL PLANS PREPARED BY KPFF/ UTILITY PLAN SHEET C1-5.1 FOR MORE INFORMATION AND COORDINATION PRESSURE MAINLINE SHALL BE LOCATED IN PLANTER IN A LOCATION FREE OF OBSTRUCTIONS AND MINIMUM OF 5' FROM TREE ROOTBALL. PLAN SHOWN FOR CLARITY PURPOSES ONLY. ASI #19 ASI #19 ASI #20 ASI #20 ASI #20 ASI #20 ASI #20 RFI 57.1 SYMBOL BOTANICAL / COMMON NAME SIZE WUCOLS QTY TREES LAURUS X 'SARATOGA' SARATOGA HYBRID LAUREL 24" BOX MED 9 PHOENIX DACTYLIFERA DATE PALM 20` BTH LOW 5 QUERCUS AGRIFOLIA COAST LIVE OAK 48" BOX LOW 5 EXISTING TREE TO REMAIN MAGNOLIA GRANDIFLORA SOUTHERN MAGNOLIA ---MED 2 SYMBOL BOTANICAL / COMMON NAME SIZE WUCOLS SPACING QTY SHRUBS ABUTILON PALMERI INDIAN MALLOW 5 GAL.LOW 48" o.c.17 ACANTHUS MOLLIS BEAR'S BREECH 5 GAL.MED 36" o.c.64 AGAVE ATTENUATA FOXTAIL AGAVE 5 GAL.LOW 48" o.c.26 ELYMUS CONDENSATUS 'CANYON PRINCE' CANYON PRINCE WILD RYE 5 GAL.LOW 48" o.c.97 FRANGULA CALIFORNICA 'EVE CASE' EVE CASE COFFEEBERRY 5 GAL.V.LOW 36" o.c.423 LIRIOPE MUSCARI 'BIG BLUE' BIG BLUE LILYTURF 5 GAL.LOW 18" o.c.4 MUHLENBERGIA RIGENS DEER GRASS 5 GAL.LOW 36" o.c.300 SALVIA CLEVELANDII 'POZO BLUE' POZO BLUE CLEVELAND SAGE 1 GAL.V.LOW 48" o.c.166 SIMMONDSIA CHINENSIS 'VISTA' JOJOBA 5 GAL.V.LOW 48" o.c.59 SYMBOL BOTANICAL / COMMON NAME SIZE WATER USE SPACING QTY SHRUB AREAS EUPHORBIA RIGIDA YELLOW SPURGE 1 GAL.LOW 18" o.c.198 SYMBOL BOTANICAL / COMMON NAME SIZE WUCOLS SPACING QTY GROUND COVERS BACCHARIS PILULARIS 'TWIN PEAKS' TWIN PEAKS COYOTE BRUSH 5 GAL.LOW 48" o.c.181 LANTANA MONTEVIDENSIS `MONMA` WHITE LIGHTNIN` TRAILING LANTANA 1 GAL.LOW 24" o.c.292 TURF MARATHON II MARATHON II SOD HIGH 2,981 SF Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z RO S S S T R E E T LI M I T O F W O R K LIMIT OF WORK SANTA ANA LIBRARY LIMIT OF WORK LIMIT OF WORK PA R K I N G S T R U C T U R E LI M I T O F W O R K KID'S AREA N.A.P. T R TR EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL EV CAPABLE PARKING STALL TR EXISTING TO REMAIN 2 3 1 LI M I T O F W O R K TR SYMBOL BOTANICAL / COMMON NAME SIZE WUCOLS QTY EXISTING PALMS TO BE RELOCATED NOTE: SHOWN WITH THE NUMBERS 1,2,3 PHOENIX CANARIENSIS CANARY ISLAND DATE PALM ---LOW 3 EXISTING PALMS TO REMAIN PHOENIX CANARIENSIS CANARY ISLAND DATE PALM ---LOW 3 ALTERNATE OPTION = PALM TRANSPLANT 1,2,3 ADJACENT #'S (1,2,3) CORRESPOND TO ALTERNATE OPTION TRANSPLANTING. REFER TO REMARKS ON LEGEND ON TREE DISPOSITION PLAN, LA-1.0 REMARKS terra n I N T E G R A T I O N Landscape Architecture CA#5231 Planning + Design + Sustainability 143 S. Olive St. Orange I CA I 92866 714-724-9814 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- 22575-01 REV #DESCRIPTION DATE #9 RFI 10.23.2024 BID SET 04/30/2024 FINAL PERMIT/ CONFORM SET 08/02/2024 #19 RFI 3.28.2025 #20 RFI 3.28.2025 #57.1 RFI 6.18.2025 PLANTING PLAN LA-4.0 PLANTING LEGEND 1.MULCH 3" MINIMUM LAYER MULCH SHALL BE APPLIED IN ALL PLANTER AREAS (NOT INCLUDING TURF AREAS). MULCH TO BE AGUINAGA FOREST FLOOR MULCH 1/2" OR APPROVED EQUAL. 2.ROOT BARRIER ROOT BARRIERS ARE REQUIRED WHERE TREES ARE PLANTED LESS THAN FIVE (5) FEET OF SIDEWALK, WALLS, STRUCTURES, CURBS, PAVING, PUBLIC IMPROVEMENTS WITHIN R.O.W. (TYP.), WATER, SEWER, STORM DRAIN, ETC. ROOT BARRIER TO BE DEEPROOT MODEL #UB 36-2 (800.458.7668) OR APPROVED EQUAL. 3.PLANT QUANTITIES CONTRACTOR TO NOTE THAT THE QUANTITIES ON LEGEND AND PLANT CALLOUTS HAVE BEEN PROVIDED FOR QUICK REFERENCE ONLY. IT IS REQUIRED THAT THE CONTRACTOR NOT RELY ON THE ACCURACY OF THESE QUANTITIES AND PROVIDE THEIR OWN PLANT MATERIAL COUNTS, BASED OFF SYMBOLS SHOWN ON PLAN, AT THE TIME OF PREPARING BID. ANY DISCREPANCY IN THE PLANT QUANTITIES AND SIZES SHOULD BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE LANDSCAPE ARCHITECT PRIOR TO PURCHASING. 4.DRAIN LINES CONTRACTOR TO LOCATE ALL DRAIN LINES IN FIELD PRIOR TO THE INSTALLATION OF TREES. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF ANY CONFLICT WITH TREE OR PALM LOCATIONS WITH STORM DRAIN LINES. 5.SOILS REPORT CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ONE (1) AGRONOMIC SOILS TESTS AND INSTALL PLANT MATERIAL PER REPORT AND SOIL RECOMMENDATIONS. 4.TREE SETBACKS TRAFFIC SIGNALS, STOP SIGNS 20 FEET UNDERGROUND UTILITY 5 FEET SEWER LINES 10 FEET ABOVE GROUND UTILITY 10 FEET DRIVEWAYS 10 FEET INTERSECTIONS (INTERSECT OF CURB LINES OF TWO STREETS) 25 FEET UNLESS OTHERWISE DIRECTED BY THE CITY OF SANTA ANA THESE MINIMUM TREE SETBACK SHALL BE MET PLANTING NOTES NORTH 0 10'20'40' SCALE: 1" = 20'-0" COMPLIANCE NOTE I HAVE COMPLIED WITH THE CRITERIA OF THE ORDINANCE AND APPLIED THEM FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLANS. 3/17/2022 LANDSCAPE ARCHITECT DATE NORTH 0 5'10'20' SCALE: 1" = 10'-0" EAST GARDEN LANDSCAPE LIGHTING CIVIC CENTER DRIVE LIGHTING LEGEND (LOW VOLTAGE) MANUFACTURER TYPE NOTE FX LUMINAIRE #A-KN-FB IN GRADE LIGHT LINE VOLT INPUT 110-277V: INTEGRATED LED LAMP: BLACK FINISH: COWLING SHROUD: DIE CAST ALUMINUM EXISTING FICUS, PROTECT IN PLACE. NOT IN SCOPE - SHOWN FOR ADDITIONAL INFORMATION EXISTING FICUS, PROTECT IN PLACE. NOT IN SCOPE - SHOWN FOR ADDITIONAL INFORMATION ADJUST PLANTS IN FIELD TO ALLOW FOR UTILITY ACCESS AND SCREENING ADJUST PLANTS IN FIELD TO ALLOW FOR UTILITY ACCESS AND SCREENING TREE IN RAISED PLANTER WITH ROOT BARRIER TO PROTECT UTILITY TREES PLANTED IN RAISED PLANTERS - NO UTILITY INTERFERENCE -MALE FRUITLESS ASI #19 ASI ASI #20 ASI ASI #19 ASI #20 ASI #20 ASI #19 ASI #20 ASI #20 ASI #20 RFI 57.1 RFI 57.1 INSERTION POINT (N) (N) (N) (N) J (N) (N) (N) (N) (N) J (N)J (N) J (N) (N) (N)(N)(N)(N)(N) (N) J (N) (N) (N) (N)(N) J (N) (N) 5' -6-1/2" 4' - 9 " 4' -0-1/2" 7' -11" 3' - 1 1 - 1 / 2 " 5' -6-1/2" 5' 5' -10" 5' 5' -6-1/2" 5' 5' -6-1/2"5' -6-1/2" 5' 7' -10" 7' -8-1/2" 7' -6" 5' 3' -9" FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT TOP AROUND COLUMN. THE OVERHEAD/SLATWALL ARE SHORTER IN THIS OFFICE DUE TO THE COLUMN. FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT TOP AROUND COLUMN. THE OVERHEAD/SLATWALL ARE SHORTER IN THIS OFFICE DUE TO THE COLUMN. WS-1 WS-1 WS-1 CR-4 CR-4 WS-1 CT-1 WS-2 CT-1 SS-1B ST-3 WS-1 CT-1 WS-3 CT-1 WS-1 WS-1 SS-1B WS-1 WS-1 SS-1A CR-4 ST-3 CT-1 SS-1B CR-3 WS-2 CT-1 WS-1 SS-1B WS-3 CT-1 ST-3 CT-1 CR-4 CR-4 WS-4 SS-1B CT-1 SS-1B CT-1 WS-3 SS-1B WS-1 TR-1B SS-1B ST-3 ST-3 WS-3 SS-1A CT-1 SS-1B CT-1 TR-1C WS-1 ST-3 SS-1B CT-1 WS-3 ST-3 CT-1 WS-1 ST-3 WS-1 SS-1B CT-1 WS-1 WS-1 CT-1 CR-4 CT-1 SS-1B CR-3 CT-1 SS-1B SS-1B CR-3 ST-3 ST-2 CT-1 SS-1A CT-1 WS-3 ST-3 CT-1 ST-3ST-3 FL-1 CT-1 SS-1A SS-1A WS-3 ST-3 WS-1 CT-1 WS-3 SS-1B WS-1 SS-1A CT-1 CT-1 SS-1A WS-1 WS-1 SS-1B CT-1 CR-3 CT-1 ST-3 ST-3 TR-1D CT-1 SS-1A CT-1 WS-1 SS-1B SS-1A SS-1A CT-1 WS-1 SS-1A WS-1 ST-3 SS-1B WS-1 ST-4 CT-1 WS-1 ST-3 ST-3 WS-4 SS-1B ST-3 ST-3 CT-1 ST-4 WS-3 CT-1 WS-4 WS-3 WS-1 WS-2 WS-3 ST-3 CT-1 CT-1 CT-1 CT-1 CT-1 WS-1 WS-3 WS-1 WS-2 WS-4 CR-3 WS-1 WS-1 CT-1 WS-3 CR-4 SS-1A SS-1B CT-1 WS-3 CT-1 CR-3 CT-1 WS-3 WS-1 SS-1A FL-1 SS-1B ST-3 CT-1 WS-1 CR-3 ST-3 SS-1B CT-1 CT-1 SS-1B SS-1A WS-2 CT-1 WS-1 CT-1 WS-4 CT-1CT-1CT-1 CT-1CT-1 3' 2' -8-1/2" 7' -6-1/2" 4' 3' -8" 2' 9' -2-1/2" 5' -4" 3' 7' 7' 1' -3" 3' 6' -11" 3' -10"3' -10" 4' -11-1/2" 2' -6" 3' -7" 2' -5-1/2" 3' 3' -2" 6' -9" 4' -10" 3' 3' -0-1/2" 4' -3" 6' -5-1/2" 3' -10" 1 4C 2 4C 2 4C 3 3 4C 1 4C 2 4C 14C 2 1 1 22 3 4C4C 3 1 4C4C 2 3 3 2 1 1 1 3 2 3 2 1 4C 1 4C 3 2 4C 4C 3 4C 2 4C 1 1 2 4C 4C 1 4C 3 4C 1 4C 3 2 4C 22 2 3 3 4C3 4C 4C 3 3 4C 4C 3 2 4C 4C 3 1 4C 3 4C 4C 3 2 1 4C4C 3 3 2 1 4C 2 4C 4C 3 4C 3 3 4C 4C 3 2 2 4C 4C 1 1 1 11 3 1 1 1 4C 3 4C 3 4C2 3 4C 3 4C 15' R SM-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 LOCL-2 SM-1 SM-1 SM-1 SM-1 FOL-2FOL-2FOL-2FOL-2FOL-2 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3FOL-3FOL-3FOL-3 FOL-3 FOL-3 SM-1 SM-1 FOL-2 FOL-2 FOL-2 FOL-2 FOL-2FOL-2FOL-2FOL-2 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-3 LOCL-2 LOCL-2 LOCL-2 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-1 LOCL-2 LOCL-2 LOCL-2 LOCL-2 FE C FE C FE C FE C FE C DW SM - 1 S M - 1 S M - 1 SM - 1 S M - 1 SM - 1 S M - 1 SM - 2 SM - 1 SM-1 SM - 1 SM - 1 SM-1 SM - 1 FE C SM - 1 INSERTION POINT (N) (N) (N) (N) J (N) (N) (N) (N) (N) J (N)J (N) J (N) (N) (N)(N)(N)(N)(N) (N) J (N) (N) (N) (N)(N) J (N) (N) 5' -6-1/2" 4' -9" 4' -0-1/2" 7' -11" 3' -11-1/2" 5' -6-1/2" 5' 5' -10" 5' 5' -6-1/2" 5' 5' -6-1/2"5' -6-1/2" 5' 7' -10" 7' -8-1/2" 7' -6" 5' 3' -9" FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT TOP AROUND COLUMN. THE OVERHEAD/SLATWALL ARE SHORTER IN THIS OFFICE DUE TO THE COLUMN. FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT WORKSURFACE AROUND COLUMN. STATION HAS A SMALLER WIDTH OVERHEAD FIELD CUT TOP AROUND COLUMN. THE OVERHEAD/SLATWALL ARE SHORTER IN THIS OFFICE DUE TO THE COLUMN. WS-1 WS-1 WS-1 CR-4 CR-4 WS-1 CT-1 WS-2 CT-1 SS-1B ST-3 WS-1 CT-1 WS-3 CT-1 WS-1 WS-1 SS-1B WS-1 WS-1 SS-1A CR-4 ST-3 CT-1 SS-1B CR-3 WS-2 CT-1 WS-1 SS-1B WS-3 CT-1 ST-3 CT-1 CR-4 CR-4 WS-4 SS-1B CT-1 SS-1B CT-1 WS-3 SS-1B WS-1 TR-1B SS-1B ST-3 ST-3 WS-3 SS-1A CT-1 SS-1B CT-1 TR-1C WS-1 ST-3 SS-1B CT-1 WS-3 ST-3 CT-1 WS-1 ST-3 WS-1 SS-1B CT-1 WS-1 WS-1 CT-1 CR-4 CT-1 SS-1B CR-3 CT-1 SS-1B SS-1B CR-3 ST-3 ST-2 CT-1 SS-1A CT-1 WS-3 ST-3 CT-1 ST-3ST-3 FL-1 CT-1 SS-1A SS-1A WS-3 ST-3 WS-1 CT-1 WS-3 SS-1B WS-1 SS-1A CT-1 CT-1 SS-1A WS-1 WS-1 SS-1B CT-1 CR-3 CT-1 ST-3 ST-3 TR-1D CT-1 SS-1A CT-1 WS-1 SS-1B SS-1A SS-1A CT-1 WS-1 SS-1A WS-1 ST-3 SS-1B WS-1 ST-4 CT-1 WS-1 ST-3 ST-3 WS-4 SS-1B ST-3 ST-3 CT-1 ST-4 WS-3 CT-1 WS-4 WS-3 WS-1 WS-2 WS-3 ST-3 CT-1 CT-1 CT-1 CT-1 CT-1 WS-1 WS-3 WS-1 WS-2 WS-4 CR-3 WS-1 WS-1 CT-1 WS-3 CR-4 SS-1A SS-1B CT-1 WS-3 CT-1 CR-3 CT-1 WS-3 WS-1 SS-1A FL-1 SS-1B ST-3 CT-1 WS-1 CR-3 ST-3 SS-1B CT-1 CT-1 SS-1B SS-1A WS-2 CT-1 WS-1 CT-1 WS-4 CT-1CT-1CT-1 CT-1CT-1 3' 2' -8-1/2" 7' -6-1/2" 4' 3' -8" 2' 9' -2-1/2" 5' -4" 3' 7' 7' 1' -3" 3' 6' -11" 3' -10"3' -10" 4' -11-1/2" 2' -6" 3' -7" 2' -5-1/2" 3' 3' -2" 6' -9" 4' -10" 3' 3' -0-1/2" 4' -3" 6' -5-1/2" 3' -10" 1 4C 2 4C 2 4C 3 3 4C 1 4C 2 4C 14C 2 1 1 22 3 4C4C 3 1 4C4C 2 3 3 2 1 1 1 3 2 3 2 1 4C 1 4C 3 2 4C 4C 3 4C 2 4C 1 1 2 4C 4C 1 4C 3 4C 1 4C 3 2 4C 22 2 3 3 4C3 4C 4C 3 3 4C 4C 3 2 4C 4C 3 1 4C 3 4C 4C 3 2 1 4C4C 3 3 2 1 4C 2 4C 4C 3 4C 3 3 4C 4C 3 2 2 4C 4C 1 1 1 11 3 1 1 1 4C 3 4C 3 4C2 3 4C 3 4C 15' FC6 2T MCP FT FC 3 FC3 FT FT FT FT FT FC3 12345678910 C D E F G H Printer + copier Misc. storage MECH 003 ELEVATOR-ABAN. 007 FIRE AL.RM 006 MECH-ABAN. 008 ARCHIVES 002 STAFF OFFICE 001 OFFICE 012 OFFICE 013 STAFF MEETING ROOM 014 OFFICE 015 ALL GENDER RESTROOM 010 OFFICE 017 Work table Compact shelving Cabinets Locker & Cabinets Snack Machine Drink Machine Work table open shelves Book shelves Op e n S h e l v e s STAFF BREAK ROOM 004 (E) ELEV. CONTROL RM. 005A OFFICE 016 Compact shelving ELECTRICAL 019 ELEV. CONTROL 018 Existing PAM Cabinet Ex i s t i n g M i c r o f i l m Ca b i n e t Ne w PA M Ca b i n e t New Cabinet STORAGE 005 Trash/ Recycle Bin JANITOR. 023 ALL GENDER RESTROOM 011 STORAGE 022 002-AA T 014-DA 4D 014-BA 4D 006-BA 2D 003-BA 4D TKN2001 TKN2002 TKN2003 001-EA O 2D 001-EB O 2D 001-ED O 2D 001-EC O 2D 001-EE O 2D 001-EF O 2D 001-EG O 2D 001-EH O 2D 001-GA O 2D 001-GB O 2D 001-GC O 2D 001-GD O 2D 001-GE O 2D 001-GF O 2D 001-GG O 2D 001-GH O 2D 001-IA O 2D 001-IB O 2D 001-IC O 2D 001-ID O 2D 001-IE O 2D 001-IF O 2D 001-IG O 2D 001-IH O 2D 001-JA O 2D 001-JB O 2D 001-JC O 2D 001-JD O 2D 001-FA O 2D 001-FB O 2D 001-FD O 2D 001-FC O 2D 001-FE O 2D 001-FF O 2D 001-FG O 2D 001-FH O 2D 001-HA O 2D 001-HB O 2D 001-HD O 2D 001-HC O 2D 001-HF O 2D 001-HE O 2D 001-HH O 2D 001-HG O 2D 001-CA 2D 001-CB 2D 001-CC 2D 018-AA 2D ELEC-BA 4D TKN2003 TKN2005 TKN2001 004-AA T 005A-DA 1D STORAGE 005 001-JE O 2D 001-JF O 2D 001-JG O 2D 001-JH O 2D 10 2 " 29" 001-KA 2D 1 ASI 009 001-LA 2D 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 012-DA 4D 1 ASI 009 013-DA 4D 1 ASI 009 014-EA 4D 1 ASI 009 014-DB A 2D 015-DA 4D 1 ASI 009 016-DA 4D 1 ASI 009 017-DA 4D 1 ASI 009 1 ASI 009 001-MA 4D 1 ASI 009 002-EA 4D 1 ASI 009 ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 TN2.1-0 COMMUNICATIONS FLOOR PLAN - BASEMENT 1/8" = 1'-0"1 COMMUNICATIONS FLOOR PLAN - BASEMENT KEYNOTES TKN2001 COORDINATE LOCATION WITH THE WORK OF DIVISION 14. TKN2002 COORDINATE LOCATION WITH THE WORK OF DIVISIONS 22, 23 & 25. TKN2003 COORDINATE LOCATION WITH THE WORK OF DIVISION 26. TKN2005 LOCATE TWO-WAY COMMUNICATIONS MASTER CONTROL PANEL ADJACENT TO FIRE ALARM CONTROL PANEL - SEE ELECTRICAL/FIRE ALARM PLANS. SHEET NOTE 1. STRUCTURED CABLING WORK OF THIS SHEET, UNLESS OTHERWISE NOTED, TO BE PROVIDED UNDER THE WORK OF A SEPARATE “E-RATE”/FCC SCHOOLS AND LIBRARY FUND CONTRACTOR USING PATHWAYS INSTALLED UNDER THE WORK OF THIS PROJECT. REV # DESCRIPTION DATE ASI 009 06/02/2025 FC6 FT FT 12345678910 C D E F G H YOUTH STACKS 117 BOOKMOBILE ROOM 103 STAFF-WOMEN RESTROOM 104 STAFF MEN RESTROOM 105 MEN RR 110 WOMEN RR 111 JAN. RM 112 MECH. 113 ALL GENDER RESTROOM 114 ALL GENDER RESTROOM 115 ADULT STACKS 119 YOUTH STACKS 118 GREAT READING ROOM 101 FIREPLACE ROOM 122 I.T. 106 SORTING 123 STORAGE 108 BOOKSTORE 109 TODDLERS AND INFANTS 120 FAMILY ZONE 121 OFFICE 103A NURSING/SENSORY 116 STORAGE 124 MEETING/COMMUNITY ROOM 102 VESTIBULE 107 VESTIBULE 100 TN4.1-0 1 117-HA 2D 117-FA 2D 108-AA 2D 123-EA 2D 123-BA 2D 123-DA 2D 103-CB 2D 102-DA 2D 103-DA 2D 103-BA 2D 102-AA 6D 102-CE 2D 102-CB 2D 102-CA 2D 100-AB 2D 122-DA 2D TKN2004 103-CA 2D 103-EA O 2D 103-EB O 2D 103A-BA 4D 101-CD 6D 117-EB 1D 117-EA 1D TKN2010 TKN2010 101-EA 6D 101-EB 4D 107-EA 1D TKN2010 TKN2010 TKN2010 101-CC 1D TKN2010 TKN2010 101-CA 6D 106-DA 3D 102-EA 4D 102-CC A 2D 102-CD A 2D 102-EB 4D 102-DB A 2D 123-EB 2D 123-AA 2D 123-DB 1D 107-BE A 1D FP4 TKN2010 TKN2012 TKN2013 FP4 FP4 FP4 FP4 FP6 FP6 101-FA 4D 101-FB 4D FP4 101-FC 2D FP4 FP4 TKN0029 FP4 100-EA 1D 107-EB 1D 101-CB 1D FP6 101-FD 4D FP6 101-FE 4D 100-AA A 1D 101-AA A 1D 101-AB A 1D 101-AC 2D 107-BA 1D 107-BB 1D 107-BC 1D 107-BD 1D 1 RFI 141 1 RFI 141 ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 TN2.1-1 COMMUNICATIONS FLOOR PLAN - FIRST FLOOR 1/8" = 1'-0"1 COMMUNICATIONS FLOOR PLAN - FIRST FLOOR KEYNOTES TKN0029 (3) 4" C. TKN2004 COORDINATE LOCATION WITH THE WORK OF DIVISION 28. TKN2010 COORDINATE WITH LOCATION OF RFID BOOK GATE STATION LOCATIONS. TKN2012 SURFACE MOUNT IN AV RACK - COORDINATE WITH LOCATION OF RACK AS SHOWN ON TA SHEETS AND WORK OF SECTION 27 41 16. TKN2013 FOR USE WITH BOOK DROP - COORDINATE WITH WORK OF BOOK DROP. SHEET NOTE 1. STRUCTURED CABLING WORK OF THIS SHEET, UNLESS OTHERWISE NOTED, TO BE PROVIDED UNDER THE WORK OF A SEPARATE “E-RATE”/FCC SCHOOLS AND LIBRARY FUND CONTRACTOR USING PATHWAYS INSTALLED UNDER THE WORK OF THIS PROJECT. REV # DESCRIPTION DATE 1 RFI 141 04.23.2025 12345678910 C D E F G H STAFF OFFICE 001 MECH 003 ALL GENDER RESTROOM 010 STAFF MEETING ROOM 014 OFFICE 013 OFFICE 012 ARCHIVES 002 ELEV. CONTROL 018 FIRE AL.RM 006 ELEVATOR-ABAN. 007 MECH-ABAN. 008 (E) ELEV. CONTROL RM. 005A STAFF BREAK ROOM 004 OFFICE 015 OFFICE 016 OFFICE 017 STORAGE 005 STAFF OFFICE 001 ALL GENDER RESTROOM 011 004-ZA W 2D 016-ZA W 2D MECH-ZA W 2D 002-ZA W 2D 001-ZA W 2D 001-ZB W 2D CORR-ZA W 2D TKN0405 TKN0029 TKN0019TKN1005 TKN1005 TKN1004 TKN1005 TKN1005 TKN1004 TKN1005 TKN1005 TKN1004 009-YA 1D 001-YA 1D TKN1007 TKN1007 J18 TKN1004 TKN1004 TKN1004 TKN1005 TKN1004 TKN0008 TKN1005 TKN0405 TKN0405TKN0405TKN0405TKN0405TKN0405TKN0405 TKN1004 TKN1005 TKN1004 TKN1005 TKN1004 TKN1004 1 RFI 159, RFI 161 1 RFI 157, RFI 161 1 RFI 159, RFI 161 1 RFI 159, RFI 161 1 RFI 159, RFI 161 1 1 RFI 159, RFI 161 1 RFI 159, RFI 161 1 RFI 159, RFI 161 1 RFI 159, RFI 161 1 RFI 159, RFI 161 1 RFI 159, RFI 161 1 RFI 159, RFI 161 1 RFI 159, RFI 161 1 RFI 159, RFI 1611 RFI 159, RFI 161 1 RFI 159, RFI 161 1 RFI 159, RFI 161 1 RFI 159, RFI 161 ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO.N ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 TN6.1-0 COMMUNICATIONS RCP - BASEMENT 1/8" = 1'-0"1 COMMUNICATIONS RCP - BASEMENT KEYNOTES TKN0008 3" C. TKN0019 (2) 4" C. TKN0029 (3) 4" C. TKN0405 18-2 CTW SUPPORTED FROM DECK. CTW LENGTH TO FIT BETWEEN BEAM. PROVIDE 6" GAP FROM SIDE OF BEAM TO CTW. TKN1004 RE-USE EXISTING CABLE TRAY AS INDICATED ON THE REFLECTED CEILING PLAN AND EXTEND EXISTING CABLE TRAY TO CTW. TKN1005 ADJUST EXISTING CABLE TRAY HEIGHT ABOVE CEILING LINE. CUT (E) CABLE TRAY LENGTH TO FIT BETWEEN BEAM, PROVIDE 6" GAP FROM SIDE OF BEAM TO (E) CABLE TRAY AND GRIND EDGE OF (E) CABLE TRAY FOR A SMOOTH FINISH. TKN1007 WAO FOR SECURITY CAMERA. SEE TY SERIES DRAWING FOR EXACT LOCATION. SHEET NOTE 1. STRUCTURED CABLING WORK OF THIS SHEET, UNLESS OTHERWISE NOTED, TO BE PROVIDED UNDER THE WORK OF A SEPARATE "E-RATE"/FCC SCHOOLS AND LIBRARY FUND CONTRACTOR USING PATHWAYS INSTALLED UNDER THE WORK OF THIS PROJECT. 2. "E-RATE" CONTRACTOR IS RESPONSIBLE TO PROVIDE THEIR OWN J-HOOKS/CABLE HOOKS AS REQUIRED. 3. ABOVE CEILING BASKET TRAY CABLE SUPPORT -TYPE CTW - WHERE INDICATED, TO BE PROVIDED UNDER THE WORK OF THE BASE BUILDING CONSTRUCTION CONTRACT. REV # DESCRIPTION DATE RFI 159, RFI 161 05/19/2025 1 RFI 159, RFI 161 1 RFI 159, RFI 161 Pl a t e S t a t i o n N o . Ro o m N o . Ro o m N a m e "F " T y p e C o n n e c t o r Ca t . 6 J a c k C o u n t U T P 6 - 4 Ca t . 6 J a c k C o u n t U T P 6 - 4 O P TO T A L F I L L Ca t 6 C k t # 1 L a b e l i n g Ca t 6 C k t # 2 L a b e l i n g Ca t 6 C k t # 3 L a b e l i n g Ca t 6 C k t # 4 L a b e l i n g Ca t 6 C k t # 5 L a b e l i n g Ca t 6 C k t # 6 L a b e l i n g "F " C o n n e c t o r C k t L a b e l i n g UT P 6 - 4 F I L L RG - 6 M F I L L Ho m e R u n L o c a t i o n No t e s BASEMENT 001-CA 001 STAFF OFFICE 0 2 0 2 0001 0002 2 IT ROOM 106 001-CB 0 2 0 2 0003 0004 2 IT ROOM 106 001-CC 0 2 0 2 0005 0006 2 IT ROOM 106 001-EA 0 2 0 2 0007 0008 2 IT ROOM 106 001-EB 0 2 0 2 0009 0010 2 IT ROOM 106 001-EC 0 2 0 2 0011 0012 2 IT ROOM 106 001-ED 0 2 0 2 0013 0014 2 IT ROOM 106 001-EE 0 2 0 2 0015 0016 2 IT ROOM 106 001-EF 0 2 0 2 0017 0018 2 IT ROOM 106 001-EG 0 2 0 2 0019 0020 2 IT ROOM 106 001-EH 0 2 0 2 0021 0022 2 IT ROOM 106 001-FA 0 2 0 2 0023 0024 2 IT ROOM 106 001-FB 0 2 0 2 0025 0026 2 IT ROOM 106 001-FC 0 2 0 2 0027 0028 2 IT ROOM 106 001-FD 0 2 0 2 0029 0030 2 IT ROOM 106 001-FE 0 2 0 2 0031 0032 2 IT ROOM 106 001-FF 0 2 0 2 0033 0034 2 IT ROOM 106 001-FG 0 2 0 2 0035 0036 2 IT ROOM 106 001-FH 0 2 0 2 0037 0038 2 IT ROOM 106 001-GA 0 2 0 2 0039 0040 2 IT ROOM 106 001-GB 0 2 0 2 0041 0042 2 IT ROOM 106 001-GC 0 2 0 2 0043 0044 2 IT ROOM 106 001-GD 0 2 0 2 0045 0046 2 IT ROOM 106 001-GE 0 2 0 2 0047 0048 2 IT ROOM 106 001-GF 0 2 0 2 0049 0050 2 IT ROOM 106 001-GG 0 2 0 2 0051 0052 2 IT ROOM 106 001-GH 0 2 0 2 0053 0054 2 IT ROOM 106 001-HA 0 2 0 2 0055 0056 2 IT ROOM 106 001-HB 0 2 0 2 0057 0058 2 IT ROOM 106 001-HC 0 2 0 2 0059 0060 2 IT ROOM 106 001-HD 0 2 0 2 0061 0062 2 IT ROOM 106 001-HE 0 2 0 2 0063 0064 2 IT ROOM 106 001-HF 0 2 0 2 0065 0066 2 IT ROOM 106 001-HG 0 2 0 2 0067 0068 2 IT ROOM 106 001-HH 0 2 0 2 0069 0070 2 IT ROOM 106 001-IA 0 2 0 2 0071 0072 2 IT ROOM 106 001-IB 0 2 0 2 0073 0074 2 IT ROOM 106 001-IC 0 2 0 2 0075 0076 2 IT ROOM 106 001-ID 0 2 0 2 0077 0078 2 IT ROOM 106 001-IE 0 2 0 2 0079 0080 2 IT ROOM 106 001-IF 0 2 0 2 0081 0082 2 IT ROOM 106 001-IG 0 2 0 2 0083 0084 2 IT ROOM 106 001-IH 0 2 0 2 0085 0086 2 IT ROOM 106 001-JA 0 2 0 2 0087 0088 2 IT ROOM 106 001-JB 0 2 0 2 0089 0090 2 IT ROOM 106 001-JC 0 2 0 2 0091 0092 2 IT ROOM 106 001-JD 0 2 0 2 0093 0094 2 IT ROOM 106 001-JE 0 2 0 2 0095 0096 2 IT ROOM 106 001-JF 0 2 0 2 0097 0098 2 IT ROOM 106 001-JG 0 2 0 2 0099 0100 2 IT ROOM 106 001-JH 0 2 0 2 0101 0102 2 IT ROOM 106 001-KA 0 2 0 2 0103 0104 2 IT ROOM 106 001-LA 0 2 0 2 0105 0106 2 IT ROOM 106 001-MA 0 4 0 4 0107 0108 0109 0110 4 IT ROOM 106 001-YA 0 1 0 1 0111 1 IT ROOM 106 001-ZA 0 2 0 2 0112 0113 2 IT ROOM 106 001-ZB 0 2 0 2 0114 0115 2 IT ROOM 106 002-AA 002 ARCHIVES 0 1 0 1 0116 1 IT ROOM 106 002-EA 0 4 0 4 0117 0118 0119 0120 4 IT ROOM 106 002-ZA 0 2 0 2 0121 0122 2 IT ROOM 106 003-BA 003 MECH 0 4 0 4 0123 0124 0125 0126 4 IT ROOM 106 003-ZA 0 2 0 2 0127 0128 2 IT ROOM 106 004-AA 004 STAFF BREAK ROOM 0 1 0 1 0129 1 IT ROOM 106 004-ZA 0 2 0 2 0130 0131 2 IT ROOM 106 005A-DA 005A (E) ELEV. CONTROL RM 0 1 0 1 0132 1 IT ROOM 106 006-BA 006 FIRE ALARM 0 2 0 2 0133 0134 2 IT ROOM 106 009-YA 009 VESTIBULE 0 1 0 1 0135 1 IT ROOM 106 012-DA 012 OFFICE 0 4 0 4 0136 0137 0138 0139 4 IT ROOM 106 013-DA 013 OFFICE 0 4 0 4 0140 0141 0142 0143 4 IT ROOM 106 014-BA 014 STAFF MEETING ROOM 0 4 0 4 0144 0145 0146 0147 4 IT ROOM 106 014-DA 0 4 0 4 0148 0149 0150 0151 4 IT ROOM 106 014-DB 0 2 0 2 0152 0153 2 IT ROOM 106 014-EA 0 4 0 4 0154 0155 0156 0157 4 IT ROOM 106 015-DA 015 OFFICE 0 4 0 4 0158 0159 0160 0161 4 IT ROOM 106 016-DA 016 OFFICE 0 4 0 4 0162 0163 0164 0165 4 IT ROOM 106 016-ZA 0 2 0 2 0166 0167 2 IT ROOM 106 017-DA 017 OFFICE 0 2 0 2 0168 0169 2 IT ROOM 106 018-AA 018 ELEV CONTROL 0 2 0 2 0170 0171 2 IT ROOM 106 ELEC-BA ELEC ELECTRICAL 0 4 0 4 0172 0173 0174 0175 4 IT ROOM 106 CORR-ZA CORR ?0 2 0 2 0176 0177 2 IT ROOM 106 TOTAL - BASEMENT 0 177 0 177 0 177 0 Min. 48 port patch panel req.4 4 Pl a t e S t a t i o n N o . Ro o m N o . Ro o m N a m e "F " T y p e C o n n e c t o r Ca t . 6 J a c k C o u n t U T P 6 - 4 Ac c e s s P o i n t J a c k C a t . 6 a J a c k Co u n t TO T A L F I L L Ca t 6 C k t # 1 L a b e l i n g Ca t 6 C k t # 2 L a b e l i n g Ca t 6 C k t # 3 L a b e l i n g Ca t 6 C k t # 4 L a b e l i n g Ca t 6 C k t # 5 L a b e l i n g Ca t 6 C k t # 6 L a b e l i n g "F " C o n n e c t o r C k t L a b e l i n g UT P 6 - 4 F I L L RG - 6 M F I L L Ho m e R u n L o c a t i o n No t e s SITE PLAN EXT-YQ EXT EXTERIOR 0 1 1 0001 1 IT 106 EXT-YR 0 1 1 0002 1 IT 106 EXT-YS 0 1 1 0003 1 IT 106 EXT-YT 0 1 1 0004 1 IT 106 EXT-YU 0 1 1 0005 1 IT 106 EXT-ZA 0 2 2 0006 0007 2 IT 106 EXT-ZB 0 2 2 0008 0009 2 IT 106 TOTAL - SITE PLAN 0 9 0 9 0 9 0 Min. 48 port patch panel req.1 1 ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 TN8.0-1 SITE PLAN & BASEMENT DEVICE SCHEDULES REV # DESCRIPTION DATE ASI 009 06/02/2025 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 1 ASI 009 Pl a t e S t a t i o n N o . Ro o m N o . Ro o m N a m e "F " T y p e C o n n e c t o r Ca t . 6 J a c k C o u n t U T P 6 - 4 Ca t . 6 J a c k C o u n t U T P 6 - 4 O P TO T A L F I L L Ca t 6 C k t # 1 L a b e l i n g Ca t 6 C k t # 2 L a b e l i n g Ca t 6 C k t # 3 L a b e l i n g Ca t 6 C k t # 4 L a b e l i n g Ca t 6 C k t # 5 L a b e l i n g Ca t 6 C k t # 6 L a b e l i n g "F " C o n n e c t o r C k t L a b e l i n g UT P 6 - 4 F I L L RG - 6 M F I L L Ho m e R u n L o c a t i o n No t e s FIRST FLOOR 100-AA 100 VESTIBULE 0 2 0 2 0001 0002 2 IT ROOM 106 100-EA 0 1 0 1 0003 1 IT ROOM 106 100-YA 0 1 0 1 0004 1 IT ROOM 106 101-AA 101 GREAT READING ROOM 0 1 0 1 0005 1 IT ROOM 106 101-AB 0 1 0 1 0006 1 IT ROOM 106 101-AC 0 2 0 2 0007 0008 2 IT ROOM 106 101-CA 0 6 0 6 0009 0010 0011 0012 0013 0014 6 IT ROOM 106 101-CB 0 1 0 1 0015 1 IT ROOM 106 101-CC 0 1 0 1 0016 1 IT ROOM 106 101-CD 0 6 0 6 0017 0018 0019 0020 0021 0022 6 IT ROOM 106 101-EA 0 4 0 4 0023 0024 0025 0026 4 IT ROOM 106 101-EB 0 4 0 4 0027 0028 0029 0030 4 IT ROOM 106 101-FA 0 4 0 4 0031 0032 0033 0034 4 IT ROOM 106 101-FB 0 4 0 4 0035 0036 0037 0038 4 IT ROOM 106 101-FC 0 2 0 2 0039 0040 2 IT ROOM 106 101-FD 0 4 0 4 0041 0042 0043 0044 4 IT ROOM 106 101-FE 0 4 0 4 0045 0046 0047 0048 4 IT ROOM 106 101-YA 0 1 0 1 0049 1 IT ROOM 106 101-YB 0 1 0 1 0050 1 IT ROOM 106 101-YC 0 1 0 1 0051 1 IT ROOM 106 101-YD 0 1 0 1 0052 1 IT ROOM 106 102-AA 102 MEETING COMMUNITY ROOM 0 6 0 6 0053 0054 0055 0056 0057 0058 6 IT ROOM 106 102-CA 0 2 0 2 0059 0060 2 IT ROOM 106 102-CB 0 2 0 2 0061 0062 2 IT ROOM 106 102-CC 0 2 0 2 0063 0064 2 IT ROOM 106 102-CD 0 2 0 2 0065 0066 2 IT ROOM 106 102-CE 0 2 0 2 0067 0068 2 IT ROOM 106 102-DA 0 2 0 2 0069 0070 2 IT ROOM 106 102-DB 0 2 0 2 0071 0072 2 IT ROOM 106 102-EA 0 4 0 4 0073 0074 0075 0076 4 IT ROOM 106 102-EB 0 4 0 4 0077 0078 0079 0080 4 IT ROOM 106 102-ZA 0 2 0 2 0081 0082 2 IT ROOM 106 102-ZB 0 2 0 2 0083 0084 2 IT ROOM 106 103-BA 103 BOOKMOBILE ROOM 0 2 0 2 0085 0086 2 IT ROOM 106 103-CA 0 2 0 2 0087 0088 2 IT ROOM 106 103-CB 0 2 0 2 0089 0090 2 IT ROOM 106 103-DA 0 2 0 2 0091 0092 2 IT ROOM 106 103-EA 0 2 0 2 0093 0094 2 IT ROOM 106 103-EB 0 2 0 2 0095 0096 2 IT ROOM 106 103-ZA 0 2 0 2 0097 0098 2 IT ROOM 106 103A-BA 103A OFFICE 0 4 0 4 0099 0100 0101 0102 4 IT ROOM 106 106-DA 106 IT 0 3 0 3 0103 0104 0105 3 IT ROOM 106 107-BA 107 VESTIBULE 0 1 0 1 0106 1 IT ROOM 106 107-BB 0 1 0 1 0107 1 IT ROOM 106 107-BC 0 1 0 1 0108 1 IT ROOM 106 107-BD 0 1 0 1 0109 1 IT ROOM 106 107-BE 0 1 0 1 0110 1 IT ROOM 106 107-EA 0 1 0 1 0111 1 IT ROOM 106 107-EB 0 1 0 1 0112 1 IT ROOM 106 107-YB 0 1 0 1 0113 1 IT ROOM 106 108-AA 108 STORAGE 0 2 0 2 0114 0115 2 IT ROOM 106 117-EA 117 YOUTH STACK 0 1 0 1 0116 1 IT ROOM 106 117-EB 0 1 0 1 0117 1 IT ROOM 106 117-FA 0 2 0 2 0118 0119 2 IT ROOM 106 117-HA 0 2 0 2 0120 0121 2 IT ROOM 106 117-ZA 0 2 0 2 0122 0123 2 IT ROOM 106 117-ZB 0 2 0 2 0124 0125 2 IT ROOM 106 117-YA 0 1 0 1 0126 1 IT ROOM 106 117-YB 0 1 0 1 0127 1 IT ROOM 106 120-ZA 120 TODDLERS AND INFANTS 0 2 0 2 0128 0129 2 IT ROOM 106 120-YA 0 1 0 1 0130 1 IT ROOM 106 120-YB 0 1 0 1 0131 1 IT ROOM 106 122-DA 122 FIRE PLACE ROOM 0 2 0 2 0132 0133 2 IT ROOM 106 122-ZA 0 2 0 2 0134 0135 2 IT ROOM 106 123-AA 123 SORTING 0 2 0 2 0136 0137 2 IT ROOM 106 123-BA 0 2 0 2 0138 0139 2 IT ROOM 106 123-DA 0 2 0 2 0140 0141 2 IT ROOM 106 123-DB 0 1 0 1 0142 1 IT ROOM 106 123-EA 0 2 0 2 0143 0144 2 IT ROOM 106 123-EB 0 2 0 2 0145 0146 2 IT ROOM 106 123-ZA 0 2 0 2 0147 0148 2 IT ROOM 106 0 0 0 0 EXT-YC EXT EXTERIOR 0 1 0 1 0149 1 IT ROOM 106 EXT-YD 0 1 0 1 0150 1 IT ROOM 106 EXT-YE 0 1 0 1 0151 1 IT ROOM 106 EXT-YF 0 1 0 1 0152 1 IT ROOM 106 EXT-YG 0 1 0 1 0153 1 IT ROOM 106 EXT-YH 0 1 0 1 0154 1 IT ROOM 106 EXT-YI 0 1 0 1 0155 1 IT ROOM 106 EXT-YJ 0 1 0 1 0156 1 IT ROOM 106 EXT-YK 0 1 0 1 0157 1 IT ROOM 106 EXT-YL 0 1 0 1 0158 1 IT ROOM 106 EXT-YM 0 1 0 1 0159 1 IT ROOM 106 EXT-YN 0 1 0 1 0160 1 IT ROOM 106 EXT-YO 0 1 0 1 0161 1 IT ROOM 106 EXT-YP 0 1 0 1 0162 1 IT ROOM 106 EXT-YQ 0 1 0 1 0163 1 IT ROOM 106 TOTAL - FIRST FLOOR 0 162 0 162 0 162 0 Min. 48 port patch panel req.4 4 Pl a t e S t a t i o n N o . Ro o m N o . Ro o m N a m e "F " T y p e C o n n e c t o r Ca t . 6 J a c k C o u n t U T P 6 - 4 Ca t . 6 J a c k C o u n t U T P 6 - 4 O P TO T A L F I L L Ca t 6 C k t # 1 L a b e l i n g Ca t 6 C k t # 2 L a b e l i n g Ca t 6 C k t # 3 L a b e l i n g Ca t 6 C k t # 4 L a b e l i n g Ca t 6 C k t # 5 L a b e l i n g Ca t 6 C k t # 6 L a b e l i n g "F " C o n n e c t o r C k t L a b e l i n g UT P 6 - 4 F I L L RG - 6 M F I L L Ho m e R u n L o c a t i o n No t e s SECOND FLOOR 200-EA 200 ADULT STACKS 0 4 0 4 0001 0002 0003 0004 4 IT ROOM 106 200-YA 0 1 0 1 0005 1 IT ROOM 106 200-YB 0 1 0 1 0006 1 IT ROOM 106 200-YC 0 1 0 1 0007 1 IT ROOM 106 200-ZA 0 2 0 2 0008 0009 2 IT ROOM 106 200-ZB 0 2 0 2 0010 0011 2 IT ROOM 106 200-ZC 0 2 0 2 0012 0013 2 IT ROOM 106 200-ZD 0 2 0 2 0014 0015 2 IT ROOM 106 200-ZE 0 2 0 2 0016 0017 2 IT ROOM 106 200-ZF 0 2 0 2 0018 0019 2 IT ROOM 106 200A-YA 200A VESTIBULE SEATING 0 2 0 2 0020 0021 2 IT ROOM 106 201-AA 201 STUDY 0 2 0 2 0022 0023 2 IT ROOM 106 201-BA 0 2 0 2 0024 0025 2 IT ROOM 106 201-BB 0 1 0 1 0026 1 IT ROOM 106 202-CA 202 STUDY 0 2 0 2 0027 0028 2 IT ROOM 106 202-CB 0 1 0 1 0029 1 IT ROOM 106 0 0 0 0 211-CA 211 YOUNG ADULT 0 2 0 2 0030 0031 2 IT ROOM 106 211-CB 0 2 0 2 0032 0033 2 IT ROOM 106 211-DA 0 1 0 1 0034 1 IT ROOM 106 211-DB 0 2 0 2 0035 0036 2 IT ROOM 106 211-DC 0 6 0 6 0037 0038 0039 0040 0041 0042 6 IT ROOM 106 211-YA 0 1 0 1 0043 1 IT ROOM 106 211-ZA 0 2 0 2 0044 0045 2 IT ROOM 106 211A-BA 211A YA STUDY BOOTH 0 1 0 1 0046 1 IT ROOM 106 211A-BB 0 2 0 2 0047 0048 2 IT ROOM 106 212-BA 212 MAKER SPACE 0 2 0 2 0049 0050 2 IT ROOM 106 212-CA 0 2 0 2 0051 0052 2 IT ROOM 106 212-CB 0 2 0 2 0053 0054 2 IT ROOM 106 212-DA 0 2 0 2 0055 0056 2 IT ROOM 106 212-DB 0 2 0 2 0057 0058 2 IT ROOM 106 212-DC 0 1 0 1 0059 1 IT ROOM 106 212-EA 0 4 0 4 0060 0061 0062 0063 4 IT ROOM 106 212-ZA 0 2 0 2 0064 0065 2 IT ROOM 106 213-BA 213 VIDEO EDITING BOOTH 0 2 0 2 0066 0067 2 IT ROOM 106 213-DA 0 2 0 2 0068 0069 2 IT ROOM 106 214-AA 214 VIDEO RECORDING BOOTH 0 2 0 2 0070 0071 2 IT ROOM 106 216-DA 216 MAKER STORAGE 0 2 0 2 0072 0073 2 IT ROOM 106 216-EA 0 4 0 4 0074 0075 0076 0077 4 IT ROOM 106 216-YA 0 1 0 1 0078 1 IT ROOM 106 220-BA 220 STUDY 0 2 0 2 0079 0080 2 IT ROOM 106 221-CA 221 STUDY 0 1 0 1 0081 1 IT ROOM 106 221-CB 0 2 0 2 0082 0083 2 IT ROOM 106 222-AA 222 HIDTORY 0 2 0 2 0084 0085 2 IT ROOM 106 222-BA 0 2 0 2 0086 0087 2 IT ROOM 106 222-BB 0 2 0 2 0088 0089 2 IT ROOM 106 222-DA 0 2 0 2 0090 0091 2 IT ROOM 106 222-EA 0 2 0 2 0092 0093 2 IT ROOM 106 222-EB 0 4 0 4 0094 0095 0096 0097 4 IT ROOM 106 222-YA 0 1 0 1 0098 1 IT ROOM 106 223-CA 223 OFFICE 0 4 0 4 0099 0100 0101 0102 4 IT ROOM 106 224-AA 224 STAFF OFFICE 0 2 0 2 0103 0104 2 IT ROOM 106 224-AB 0 2 0 2 0105 0106 2 IT ROOM 106 224-CA 0 2 0 2 0107 0108 2 IT ROOM 106 224-DA 0 2 0 2 0109 0110 2 IT ROOM 106 224-ZA 0 2 0 2 0111 0112 2 IT ROOM 106 225-CA 225 STAFF OFFICE 0 4 0 4 0113 0114 0115 0116 4 IT ROOM 106 226-CA 226 OFFICE 0 4 0 4 0117 0118 0119 0120 4 IT ROOM 106 226-ZA 0 2 0 2 0121 0122 2 IT ROOM 106 TOTAL - SECOND FLOOR 0 122 0 122 0 122 0 Min. 48 port patch panel req.3 3 ST 09-30-2025 O ARCHITECT FOFCALE REN. AT ARN NO. SE LICNE C-27893 D T EC HIT ARC DAVID SCHNEE I U E I H U 9 AS.O A FRANCN 4 0 8 0 H I N S L11 AL E CR NDEN VA ,N I N G CRAE TCEI T SC S N N G R O U P 7 S 5 06 C 07 18 2 P R A O 90 A EU C + ER 4 SHEET TITLE AND NO. ISSUE DATE PROJECT: CA REG. Project Arch.---- ---- BID SET FINAL PERMIT/CONFORM SET 04/30/2024 08/02/2024 22575-01 26 CIVIC CENTER PLAZA SANTA ANA CA 92701 SANTA ANA LIBRARY RENOVATION CITY OF SANTA ANA 26 CIVIC CENTER PLAZA SANTA ANA, CA 92701 TN8.0-2 FIRST & SECOND FLOOR DEVICE SCHEDULES REV # DESCRIPTION DATE 1 RFI 141 04.23.2025 1 RFI 141 1 RFI 141 1 RFI 141 1 RFI 141 City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-1 SECTION 08 71 00 - DOOR HARDWARE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions of Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes items known commercially as finish or door hardware that are required for swing, sliding, and folding doors, except special types of unique hardware specified in the same sections as the doors and door frames on which they are installed. B. This Section includes the following, but is not necessarily limited to: 1. Door Hardware, including electric hardware. 2. Storefront and Entrance door hardware. 3. Thresholds, gasketing and weather-stripping. C. Related Sections: The following sections are noted as containing requirements that relate to this Section, but may not be limited to this listing. D. 1. Division 8: Section – Hollow Metal Doors and Frames. 2. Division 8: Section - Flush Wood Doors. 3. Division 8: Section - Aluminum Storefront. 4. Division 28: Section - Fire/Life-Safety Systems & Security Access Systems. 1.3 REFERENCES (USE DATE OF STANDARD IN EFFECT AS OF BID DATE.) A. 2022 California Building Code, CCR, Title 24. B. BHMA – Builders’ Hardware Manufacturers Association C. CCR – California Code of Regulations, Title 24, Part 2, California State Accessibility Standards. D. DHI – Door and Hardware Institute E. NFPA - National Fire Protection Association. 1. NFPA 80 - Fire Doors and Other Opening Protectives 2. NFPA 105 - Smoke and Draft Control Door Assemblies F. UL - Underwriters Laboratories. 1. UL 10C - Fire Tests of Door Assemblies 2. UL 305 - Panic Hardware G. WHI - Warnock Hersey Incorporated H. SDI - Steel Door Institute City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-2 DOOR HARDWARE 1.4 SUBMITTALS & SUBSTITUTIONS A. General: Submit in accordance with Conditions of the Contract and Division 1 Specification sections. B. Submit product data (catalog cuts) including manufacturers' technical product information for each item of door hardware, installation instructions, maintenance of operating parts and finish, and other information necessary to show compliance with requirements. C. Submit six (6) copies of schedule organized vertically into “Hardware Sets” with index of doors and headings, indicating complete designations of every item required for each door or opening. Include following information: 1. Include a Cover Sheet with; a. Job Name, location, telephone number. b. Architects name, location and telephone number. c. Contractors name, location, telephone number and job number. d. Suppliers name, location, telephone number and job number. e. Hardware consultant's name, location and telephone number. 2. Job Index information included; a. Numerical door number index including; door number, hardware heading number and page number. b. Complete keying information (referred to DHI hand-book "Keying Systems and Nomenclature"). Provision should be made in the schedule to provide keying information when available; if it is not available at the time the preliminary schedule is submitted. c. Manufacturers' names and abbreviations for all materials. d. Explanation of abbreviations, symbols, and codes used in the schedule. e. Mounting locations for hardware. f. Clarification statements or questions. g. Catalog cuts and manufacturer’s technical data and instructions. 3. Vertical schedule format sample: Heading Number 1 (Hardware group or set number – HW -1) (a) 1 Single Door #1 - Exterior from Corridor 101 (b) 90° (c) RH (d) 3' 0"x7' 0" x 1-3/4" x (e) 20 Minute (f) WD x HM (g) 1 (h) (i) ea (j) Hinges - (k) 5BB1HW 4.5 x 4.5 NRP (l) ½ TMS (m) 626 (n) IVE 2 6AA 1 ea Lockset - ND50PD x RHO x RH x 10-025 x JTMS 626 SCH (a) - Single or pair with opening number and location. (b) - Degree of opening (c) - Hand of door(s) (d) - Door and frame dimensions and door thickness. (e) - Label requirements if any. (f) - Door by frame material. (g) - (Optional) Hardware item line #. (h) - Keyset Symbol. (i) - Quantity. (j) - Product description. (k) - Product Number. (l) - Fastenings and other pertinent information. (m) - Hardware finish codes per ANSI A156.18. (n) - Manufacture abbreviation. D. Make substitution requests in accordance with Division 1. Substitution requests must be made prior to bid date. Include product data and indicate benefit to the project. Furnish samples of any proposed substitution. City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-3 E. Wiring Diagrams: Provide product data and wiring and riser diagrams for all electrical products listed in the Hardware Schedule portion of this section. F. Keying Schedule: Submit separate detailed schedule indicating clearly how the City's final instructions on keying of locks has been fulfilled. G. Templates for doors, frames, and other work specified to be factory prepared for the installation of door hardware. Check shop drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements. H. Furnish as-built/as-installed schedule with close-out documents, including keying schedule and transcript, wiring/riser diagrams, manufacturers’ installation and adjustment and maintenance information. I. LEED Certification Points: Submit information and certifications necessary to achieve maximum points for LEED certification; coordinate and cooperate with Owner and Architect in providing information necessary for required LEED rating. 1.5 QUALITY ASSURANCE A. Obtain each type of hardware (latch and lock sets, hinges, closers, exit devices, etc.) from a single manufacturer. B. Supplier Qualifications: A recognized architectural door hardware supplier, with warehousing facilities in the project's vicinity, that has a record of successful in-service performance for supplying door hardware similar in quantity, type, and quality to that indicated for this project and that employs an experienced architectural hardware consultant (AHC) who is available to Owner, Architect, and Contractor, at reasonable times during the course of the Work, for consultation. 1. Responsible for detailing, scheduling and ordering of finish hardware. 2. Meet with Owner to finalize keying requirements and to obtain final instructions in writing. 3. Stock parts for products supplied and are capable of repairing and replacing hardware items found defective within warranty periods. C. Hardware Installer: Company specializing in the installation of commercial door hardware with five years documented experience. D. Fire-Rated Openings: Provide door hardware for fire-rated openings that complies with NFPA Standard No. 80 and requirements of authorities having jurisdiction. Provide only items of door hardware that are listed and tested by UL or Warnock Hersey for given type/size opening and degree of label. Provide proper latching hardware, door closers, approved-bearing hinges and seals whether listed in the Hardware Schedule or not. 1. Where emergency exit devices are required on fire-rated doors, (with supplementary marking on doors' UL labels indicating "Fire Door to be Equipped with Fire Exit Hardware") provide UL label on exit devices indicating "Fire Exit Hardware". E. Exit Doors: Operable from inside with single motion without the use of a key or special knowledge or effort. F. Product packaging to be labelled in compliance with CA Prop 65, Safe Drinking Water and Toxic Enforcement Act of 1986. 1.6 DELIVERY, STORAGE AND HANDLING A. Coordinate delivery of packaged hardware items to the appropriate locations (shop or field) for installation. City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-4 DOOR HARDWARE B. Hardware items shall be individually packaged in manufacturers’ original containers, complete with proper fasteners. Clearly mark packages on outside to indicate contents and locations in hardware schedule and in work. C. Provide locked storage area for hardware, protect from moisture, sunlight, paint, chemicals, etc. D. Contractor to inventory door hardware jointly with representatives of hardware supplier and hardware installer until each all are satisfied that count is correct. 1.7 WARRANTY A. Provide warranties of respective manufacturers’ regular terms of sale from day of project acceptance as follows: 1. Locksets: Seven (7) years. 2. Electronic: One (1) year. 3. Closers: Thirty (30) years. 4. Exit devices: Three (3) years. 5. All other hardware: Two (2) years. 1.8 MAINTENANCE A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions as needed for Owner's continued adjustment, maintenance, and removal and replacement of door hardware. 1.9 PRE-INSTALLATION CONFERENCE A. Convene a pre-installation conference at least one week prior to beginning work of this section. B. Attendance: Architect, Construction Manager, Contractor, Security Contractor, Hardware Supplier, Installer, Key Owner Personnel, and Project Inspector. C. Agenda: Review hardware schedule, products, installation procedures and coordination required with related work. Review City's keying standards. City to provide keying schedule. PRODUCTS 1.10 MANUFACTURERS Item Manufacturer Acceptable Substitutes Hinges Ives Hager, Stanley, McKinney Locks, Latches & Cylinders Corbin Russwin Owner Standard Exit Devices Von Duprin Or Approved Equal Closers LCN Or Approved Equal Push, Pulls & Protection Plates Ives Trimco, BBW, DCI Flush Bolts Ives Trimco, BBW, DCI City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-5 Stops Ives Trimco, BBW, DCI Overhead Stops Glynn-Johnson Or Approved Equal Thresholds Zero Pemko, National Guard Seals & Bottoms Zero Pemko, National Guard 1.11 MATERIALS A. Hinges: Exterior out-swinging door butts shall be non-ferrous material and shall have stainless steel hinge pins. All doors to have non-rising pins. Provide ball bearing hinges at all exterior doors and doors with closers. B. 1. Hinges shall be sized in accordance with the following: a. Height: 1) Doors up to 42" wide: 4-1/2" inches. 2) Doors 42" to 48" wide: 5 inches. b. Width: Sufficient to clear frame and trim when door swings 180 degrees. c. Number of Hinges: Furnish 3 hinges per leaf to 7'-5" in height. Add one for each additional 2 feet in height. 2. Furnish non-removable pins (NRP) at all exterior out-swing doors and interior key lock doors with reverse bevels. C. Continuous Hinges: As manufactured by Ives, an Allegion Company. UL rated as required. D. Heavy Duty Cylindrical Locks and Latches: Corbin Russwin CL3300 1. Provide cylindrical locksets exceeding the ANSI/BHMA A156.2 Grade 1 performance standards for strength, security, and durability in the categories below: 2. Cycle life - tested to minimum 16 million cycles per ANSI/BHMA A156.2 Cycle Test with no visible lever sag or use of performance aids such as set screws or spacers 3. UL 10C for 4’-0” x 10’-0” 3-hour fire door. 4. Cylinders: Refer to “KEYING” article, herein. 5. Provide locks with standard 2-3/4 inches (70 mm) backset, unless noted otherwise, with 1/2 inch latch throw capable of UL listing of 3 hours on a 4’ x 10’ opening. Provide proper latch throw for UL listing at pairs. 6. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim. 7. Provide wired electrified options as scheduled in the hardware sets. 8. Lever Trim: Solid cast levers without plastic inserts, and wrought roses on both sides. E. Exit devices: Von Duprin as scheduled. 1. Provide certificate by independent testing laboratory that device has completed over 1,000,000 cycles and can still meet ANSI/BHMA A156.3 - 2001 standards. 2. All internal parts shall be of cold-rolled steel with zinc dichromate coating. 3. Mechanism case shall have an average thickness of .140". 4. Compression spring engineering. 5. Non-handed basic device design with center case interchangeable with all functions. 6. All devices shall have quiet return fluid dampeners. 7. All latchbolts shall be deadlocking with ¾” throw and have a self-lubricating coating to reduce friction and wear. 8. Device shall bear UL label for fire and or panic as may be required. 9. All surface strikes shall be roller type and utilize a plate underneath to prevent movement. 10. Lever Trim: “Breakaway” design, forged brass or bronze escutcheon with a minimum of .130” thickness, match lockset lever design. City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-6 DOOR HARDWARE 11. Removable Mullions: Removable with single turn of building key. Securely reinstalled without need for key. 12. Furnish glass bead kits for vision lites where required. 13. All Exit Devices to be sex-bolted to the doors. 14. Panic Hardware shall comply with CBC Section 11B.404.2.7 and shall be mounted between 34" and 44" above the finished floor surface. a. Provide exit devices UL certified to meet maximum 5 pound requirements according to the California Building Code section 11B-309.4, and UL listed for Panic Exterior Fire Exit Hardware. b. F. Closers: LCN or approved equal. Place closers inside building, stairs, room, etc. 1. Door closer cylinders shall be of high strength cast iron construction with double heat treated pinion shaft to provide low wear operating capabilities of internal parts throughout the life of the installation. All door closers shall be tested to ANSI/BHMA A156.4 test requirements by a BHMA certified testing laboratory. A written certification showing successful completion of a minimum of 10,000,000 cycles must be provided. 2. All door closers shall be fully hydraulic and have full rack and pinion action with a shaft diameter of a minimum of 11/16 inch and piston diameter of 1 inch to ensure longevity and durability under all closer applications. 3. All parallel arm closers shall incorporate one piece solid forged steel arms with bronze bushings. 1-9/16” steel stud shoulder bolts, shall be incorporated in regular arms, hold- open arms, arms with hold open and stop built in. All other closers to have forged steel main arms for strength, durability, and aesthetics for versatility of trim accommodation, high strength and long life. 4. All parallel arm closers so detailed shall provide advanced backcheck for doors subject to severe abuse or extreme wind conditions. This advanced backcheck shall be located to begin cushioning the opening swing of the door at approximately 45 degrees. The intensity of the backcheck shall be fully adjustable by tamper resistant non-critical screw valve. 5. Closers shall be installed to permit doors to swing 180 degrees. 6. All closers shall utilize a stable fluid withstanding temperature range of 120 degrees F. to - 30 degrees F. without requiring seasonal adjustment of closer speed to properly close the door. 7. Provide the manufactures drop plates, brackets and spacers as required at narrow head rails and special frame conditions. NO wood plates or spacers will be allowed. 8. Maximum effort to operate closers shall not exceed 5 lbs., such pull or push effort being applied at right angles to hinged doors. Compensating devices or automatic door operators may be utilized to meet the above standards. When fire doors are required, the maximum effort to operate the closer may be increased but shall not exceed 15 lbs. when specifically approved by fire marshal. All closers shall be adjusted to operate with the minimum amount of opening force and still close and latch the door. These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. Per 11B-404.2.8.1, door shall take at least 5 seconds to move from an open position of 90 degrees to a position of 12 degrees from the latch jamb. G. Flush Bolts & Dust Proof Strikes: Automatic Flush Bolts shall be of the low operating force design. Utilize the top bolt only model for interior doors where applicable and as permitted by testing procedures. 1. Manual flush bolts only permitted on storage or mechanical openings as scheduled. 2. Provide dust proof strikes at openings using bottom bolts. H. Door Stops: 1. Unless otherwise noted in Hardware Sets, provide floor type with appropriate fasteners. Where wall type cannot be used, provide floor type. If neither can be used, provide overhead type. City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-7 2. Do not install floor stops more than four (4) inches from the face of the wall or partition (2016 CBC Section 11B-307). 3. Overhead stops shall be made of stainless steel and non-plastic mechanisms and finished metal end caps. Field-changeable hold-open, friction and stop-only functions. I. Protection Plates: Fabricate either kick, armor, or mop plates with four beveled edges. Provide kick plates 10" high and 2" LDW. Sizes of armor and mop plates shall be listed in the Hardware Schedule. Furnish with machine or wood screws of bronze or stainless to match other hardware. J. Thresholds: As Scheduled and per details. 1. Thresholds shall not exceed 1/2" in height, with a beveled surface of 1:2 maximum slope. 2. Set thresholds in a full bed of butyl-rubber or polyisobutylene mastic sealant complying with requirements in Division 7 “Thermal and Moisture Protection”. 3. Use ¼” fasteners, red-head flat-head sleeve anchors (SS/FHSL). 4. Thresholds shall comply with CBC Section 11B-404.2.5. K. Seals: Provide silicone gasket at all rated and exterior doors. 1. Fire-rated Doors, Resilient Seals: UL10C Classified complies with NFPA 80 & NFPA 252. Coordinate with selected door manufacturers' and selected frame manufacturers' requirements. 2. Fire-rated Doors, Intumescent Seals: Furnished by selected door manufacturer. Furnish fire-labeled opening assembly complete and in full compliance with UL10C Classified complies with NFPA 80 & NFPA 252. Where required, intumescent seals vary in requirement by door type and door manufacture -- careful coordination required. 3. Smoke & Draft Control Doors, Provide UL10C Classified complies with NFPA 80 & NFPA 252 for use on “S” labeled Positive Pressure door assemblies. 1.12 KEYING A. Furnish a masterkey system as directed by the owner or architect. B. A detailed keying schedule is to be prepared by the City and/or architect. Each keyed cylinder on every keyed lock is to be listed separately showing the door #, key group (in BHMA terminology), cylinder type, finish and location on the door. C. Furnish construction keying for doors requiring locking during construction. D. Furnish all keys with visual key control. (Not all options listed below are available at the same time.) 1. Stamp key “Do Not Duplicate”. 2. Stamp (BHMA) key symbol on key. 3. Delete key “bitting” from the key bow. E. Furnish all cylinders with visual key control. (Not all options listed below are available at the same time.) 1. Stamp (BHMA) key symbol on face of cylinder plug (VKC). F. Furnish mechanical keys as follows: 1. Furnish 2 cut change keys for each different change key code. 2. Furnish 1 uncut key blank for each change key code. 3. Furnish 6 cut masterkeys for each different masterkey set. 4. Furnish 3 uncut key blanks for each masterkey set. 5. Furnish 2 cut control keys cut to the top masterkey for permanent I/C cylinders. 6. Furnish 1 cut control key cut to each SKD combination. City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-8 DOOR HARDWARE 1.13 FINISHES A. Generally to be brushed chrome (626 on bronze/brass and 652 on steel) unless otherwise noted. B. Door closers shall be powder-coated to match other hardware, unless otherwise noted. C. Aluminum items to be finished anodized aluminum except thresholds which can be furnished as standard mill finish. 1.14 FASTENERS A. Screws for strikes, face plates and similar items shall be flat head, countersunk type, provide machine screws for metal and standard wood screws for wood. B. Screws for butt hinges shall be flathead, countersunk, full-thread type. C. Fastening of closer bases or closer shoes to doors shall be by means of sex bolts and spray painted to match closer finish. D. Provide expansion anchors for attaching hardware items to concrete or masonry. E. All exposed fasteners shall have a phillips head. F. Finish of exposed screws to match surface finish of hardware or other adjacent work. G. All Exit Devices and Lock Protectors shall be fastened to the door by the means of sex bolts or through bolts. EXECUTION 1.15 INSPECTION A. Verify that doors and frames are square and plumb and ready to receive work and dimensions are as instructed by the manufacturer. B. Beginning of installation means acceptance of existing conditions. C. Fire-Rated Door Assembly Inspection: Upon completion of the installation, all fire door assemblies shall be inspected to confirm proper operation of the closing device and latching device and that only the manufacturer’s furnished fasteners are used for installation and that it meets all criteria of a fire door assembly per NFPA 80 (Standard for Fire Doors and Other Opening Protectives) 2016 Edition. A written record shall be maintained and transmitted to the Owner to be made available to the Authority Having Jurisdiction (AHJ). The inspection of the swinging fire doors shall be performed by a certified FDAI (Fire Door Assembly Inspector) with knowledge and understanding of the operating components of the type of door being subjected to the inspection. The record shall list each fire door assembly throughout the project and include each door number, an itemized list of hardware set components at each door opening, and each door location in the facility. 1.16 INSTALLATION A. Install hardware in accordance with manufacturer's instructions and requirements of DHI. B. Use the templates provided by hardware item manufacturer. City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-9 C. Mounting heights for hardware shall be as recommended by the Door and Hardware Institute. Operating hardware will to be located between 34" and 44" AFF. D. Set units level, plumb and true to line and location. Adjust and reinforce the attachment substrate as necessary for proper installation and operation. E. Drill and countersink units that are not factory-prepared for anchorage fasteners. Space fasteners and anchors in accordance with industry standards. F. Set thresholds for exterior doors in full bed of butyl-rubber sealant. G. If hand of door is changed during construction, make necessary changes in hardware at no additional cost. H. Hardware Installer shall coordinate with security contractor to route cable to connect electrified locks, panic hardware and fire exit hardware to power transfers or electric hinges at the time these items are installed so as to avoid disassembly and reinstallation of hardware. I. Hardware Installer shall also be present with the security contractor when the power is turned on for the testing of the electronic hardware applications. Installer shall make adjustments to solenoids, latches, vertical rods and closers to insure proper and secure operation. J. All wiring for electro-mechanical hardware mounted on the door shall be connected through the power transfer and terminated in the interface junction box specified for in the Electrical Section. K. Conductors shall be minimum 18 gage stranded, multicolored. A minimum 12 in. loop of conductors shall be coiled in the interface junction box. Each conductor shall be permanently marked with its function. L. If a power supply is specified in the hardware sets, all conductors shall be terminated in the power supply. Make all connections required for proper operation between the power supply and the electro-mechanical hardware. Provide the proper size conductors as specified in the manufacturer’s technical documentation. 1.17 ADJUST AND CLEAN A. Adjust and check each operating item of hardware and each door, to ensure proper operation or function of every unit. Replace units which cannot be adjusted to operate freely and smoothly as intended for the application made. B. Clean adjacent surface soiled by hardware installation. C. Final Adjustment: Wherever hardware installation is made more than one month prior to acceptance or occupancy, return to that work area and make final check and adjustment of all hardware items in such space or area. Clean operating items as necessary to restore proper function and finish of hardware and doors. Adjust door control devices to compensate for final operation of heating and ventilating equipment. D. Instruct Owner's Personnel in proper adjustment and maintenance of hardware finishes, during the final adjustment of hardware. E. Continued Maintenance Service: Approximately six months after the completion of the project, the Contractor accompanied by the Architectural Hardware Consultant, shall return to the project and re-adjust every item of hardware to restore proper functions of doors and hardware. Consult with and instruct Owner's personnel in recommended additions to the maintenance procedures. Replace hardware items which have deteriorated or failed due to faulty design, materials or City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-10 DOOR HARDWARE installation of hardware units. Prepare a written report of current and predictable problems (of substantial nature) in the performance of the hardware. 1.18 HARDWARE LOCATIONS A. Conform to CCR, Title 24, Part 2; and ADAAG; and the drawings for access-compliant positioning requirements for the disabled. 1.19 FIELD QUALITY CONTROL A. Contractor is responsible for providing the services of an Architectural Hardware Consultant (AHC) or a proprietary product technician to inspect installation and certify that hardware and its installation have been furnished and installed in accordance with manufacturers’ instructions and as specified herein. 1.20 SCHEDULE A. The items listed in the following schedule shall conform to the requirements of the foregoing specifications. B. While the hardware schedule is intended to cover all doors, and other movable parts of the building, and establish type and standard of quality, the contractor is responsible for examining the Plans and Specifications and furnishing proper hardware for all openings whether listed or not. If there are any omissions in hardware groups in regard to regular doors they shall be called to the attention of the Architect prior to bid opening for instruction; otherwise, list will be considered Complete. No extras will be allowed for omissions. C. The Door Schedule on the Drawings indicates which hardware set is used with each door. Manufacturers Abbreviation Name ACC Accurate Lock & Hardware Co C-R Corbin Russwin Architectural Hardware CAV Cavity Slider CRO Crown Industrial GLY Glynn-Johnson Corp IVE H.B. Ives LCN LCN Commercial Division SCE Schlage Electronic Security SCH Schlage Lock Company STA Stanley Security Solutions VON Von Duprin WIK Wikk Industries ZER Zero International Inc City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-11 99299 OPT0342167 VERSION 3 GROUP NO. (E) EXISTING HARDWARE TO REMAIN GROUP NO. 01 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA STOREROOM LOCK SET CLX3357 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA OH STOP 90S 630 GLY GROUP NO. 02 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA STOREROOM LOCK SET CLX3357 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA WALL STOP WS401/402CVX 626 IVE 3 EA SILENCER SR64 GRY IVE GROUP NO. 03 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA STOREROOM LOCK SET CLX3357 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP CUSH 689 LCN 1 EA GASKETING 188SBK PSA BK ZER City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-12 DOOR HARDWARE GROUP NO. 04 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA STOREROOM LOCK SET CLX3357 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP 689 LCN 1 EA WALL STOP WS401/402CVX 626 IVE 1 EA GASKETING 188SBK PSA BK ZER GROUP NO. 05 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA OFFICE LOCK 8824 LXL 626 ACC 1 EA LEVER TRIM MATCH BUILDING STANDARD 626 C-R 1 EA MORTISE CYLINDER AS REQUIRED BY NARROW STILE LOCK MFR 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA FLOOR STOP FS439 682 IVE GROUP NO. 06 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA OFFICE LOCK 8824 LXL 626 ACC 1 EA LEVER TRIM MATCH BUILDING STANDARD 626 C-R 1 EA MORTISE CYLINDER AS REQUIRED BY NARROW STILE LOCK MFR 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA FLOOR STOP FS439 682 IVE 1 SET SEAL BY AL FRAME MANUFACTURER 1 EA DOOR BOTTOM 364AA AA ZER City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-13 GROUP NO. 07 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA CLASSROOM LOCK 8845 LXL 626 ACC 1 EA LEVER TRIM MATCH BUILDING STANDARD 626 C-R 1 EA MORTISE CYLINDER AS REQUIRED BY NARROW STILE LOCK MFR 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA FLOOR STOP FS439 682 IVE GROUP NO. 08 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA CLASSROOM LOCK 8845 LXL 626 ACC 1 EA LEVER TRIM MATCH BUILDING STANDARD 626 C-R 1 EA MORTISE CYLINDER AS REQUIRED BY NARROW STILE LOCK MFR 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP REG OR PA AS REQ 689 LCN 1 EA FLOOR STOP FS439 682 IVE GROUP NO. 09 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA PRIVACY LOCK ML2030 PSA V20 626 C-R 1 EA SURFACE CLOSER 4040XP 689 LCN 1 EA WALL STOP WS401/402CVX 626 IVE City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-14 DOOR HARDWARE GROUP NO. 10 2 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 652 IVE 1 EA EU MORTISE LOCK L9492LEU 17A L583-363 XL13-346 RX DM CON 12/24 VDC 626 SCH 1 EA MORTISE CYLINDER CR1080 CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP 689 LCN 1 EA WALL STOP WS401/402CVX 626 IVE CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 TURNING THUMBTURN SHUNTS POWER TO THE CARD READER. GROUP NO. 11 2 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 652 IVE 1 EA EU STOREROOM LOCK CLX33905 M92 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP 689 LCN 1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE 1 EA WALL STOP WS401/402CVX 626 IVE CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-15 GROUP NO. 12 2 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 652 IVE 1 EA EU STOREROOM LOCK CLX33905 M92 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP 689 LCN 1 EA WALL STOP WS401/402CVX 626 IVE 1 SET SEAL BY AL FRAME MANUFACTURER 1 EA DOOR BOTTOM 364AA AA ZER 1 EA VIEWER U698 (@ 222) 626 IVE CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 GROUP NO. 13 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA EU STOREROOM LOCK CLX33905 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP EDA 689 LCN 1 EA WALL STOP WS401/402CVX 626 IVE GROUP NO. 14 2 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 652 IVE 1 EA EU STOREROOM LOCK CLX33905 M92 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA OH STOP 100S 630 GLY 1 EA SURFACE CLOSER 4040XP ST-1630 689 LCN 1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE 1 EA WALL STOP WS401/402CVX 626 IVE CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-16 DOOR HARDWARE GROUP NO. 15 2 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 652 IVE 1 EA EU STOREROOM LOCK CXL33905 M92 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP REG OR PA AS REQ 689 LCN 1 EA WALL STOP WS401/402CVX 626 IVE 1 EA DOOR BOTTOM 364AA AA ZER CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 GROUP NO. 16 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA PASSAGE SET CLX3310 PZD 626 C-R 1 EA SURFACE CLOSER 4040XP 689 LCN 1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE 1 EA WALL STOP WS401/402CVX 626 IVE GROUP NO. 17 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA PASSAGE SET CLX3310 PZD 626 C-R 1 EA SURFACE CLOSER 4040XP 689 LCN 1 EA MAGNET SEM7850 12V/24V/120V 689 LCN 1 EA GASKETING 188SBK PSA BK ZER MAG HOLDER TIED TO FIRE ALARM City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-17 GROUP NO. 18 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA FIRE EXIT HARDWARE AX-98-L-NL-F-17 626 VON 1 EA RIM CYLINDER CR3080 CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP CUSH 689 LCN 1 EA GASKETING 188SBK PSA BK ZER GROUP NO. 19 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA STOREROOM LOCK SET CLX3357 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP EDA 689 LCN 1 EA WALL STOP WS401/402CVX 626 IVE 1 EA DOOR BOTTOM 364AA AA ZER GROUP NO. 20 2 EA CONT. HINGE 112XY EPT 628 IVE 2 EA POWER TRANSFER EPT10 689 VON 1 EA ELEC PANIC HARDWARE RX-QELX-AX-3549A-EO-LBL 626 VON 1 EA ELEC PANIC HARDWARE RX-QELX-AX-3549A-NL-OP-388- LBL 626 VON 1 EA RIM CYLINDER CR3080 CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 2 EA 90 DEG OFFSET PULL 8190EZHD 10" O 630-316 IVE 2 EA SURFACE CLOSER 4040XP SCUSH 689 LCN 1 SET SEAL BY AL FRAME MANUFACTURER 2 EA DOOR BOTTOM 364AA AA ZER CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-18 DOOR HARDWARE GROUP NO. 21 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 652 IVE 1 EA MORTISE EU LOCK M8859EU AE LXL 626 ACC 1 EA LEVER TRIM MATCH BUILDING STANDARD 626 C-R 1 EA MORTISE CYLINDER AS REQUIRED BY NARROW STILE LOCK MFR 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP 689 LCN 1 EA FLOOR STOP FS439 682 IVE CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 GROUP NO. 22 1 EA ELECTRIC HINGE 5BB1 TW8 - SIZE AND THICKNESS TO MATCH EXISTING 652 IVE 1 EA ELEC TRIM M996-L-RV-17-FS 626 VON 1 EA RIM CYLINDER CR3080 CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 BALANCE OF HARDWARE EXISTING TO REMAIN City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-19 GROUP NO. 23 – NOT USED GROUP NO. 24 1 EA CONT. HINGE 112XY 628 IVE 1 EA CONT. HINGE 112XY TWP 628 IVE 1 EA MANUAL FLUSH BOLT FB458 626 IVE 1 EA MORTISE EU LOCK M8859EU LXL 626 ACC 1 EA LEVER TRIM MATCH BUILDING STANDARD 626 C-R 1 EA MORTISE CYLINDER AS REQUIRED BY NARROW STILE LOCK MFR 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP EDA 689 LCN CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 GROUP NO. 25 3 EA HINGE 5BB1 5 X 4.5 652 IVE 1 EA STOREROOM LOCK SET CLX3357 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA OH STOP 90S 630 GLY 3 EA SILENCER SR64 GRY IVE GROUP NO. 26 6 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA MANUAL FLUSH BOLT FB458 626 IVE 1 EA PASSAGE SET CLX3310 PZD 626 C-R 2 EA OH STOP 100S 630 GLY 2 EA SILENCER SR64 GRY IVE City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-20 DOOR HARDWARE GROUP NO. 27 1 SET POCKET DOOR TRACK AND HARDWARE CSS4K4080 AL CAV 1 EA SLIDING DOOR LOCK 2001ADAP-3 626 ACC 1 EA MORTISE CYLINDER CR1080 CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R GROUP NO. 29 - NOT USED GROUP NO. 30 4 EA GATE HINGE BB855A 5" X 6" OR BY GATE FABRICATOR 600 STA 2 EA CANE BOLT 0524.00021 Z CRO 1 EA PADLOCK MATCH KEYING SYSTEM 606 C-R 1 EA HASP 7" FLAT CRO GROUP NO. 31 3 EA HINGE 5BB1 4.5 X 4.5 NRP 630 IVE 1 EA STOREROOM LOCK SET CLX3357 PZD 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP SCUSH SRI 689 LCN 3 EA SILENCER SR64 GRY IVE GROUP NO. 32 6 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA MANUAL FLUSH BOLT FB358 626 IVE 1 EA STOREROOM LOCK SET CLX3357 PZD 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 2 EA OH STOP 90S 630 GLY City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-21 GROUP NO. 33 2 EA HINGE 5BB1 5 X 4.5 652 IVE 1 EA ELECTRIC HINGE 5BB1 5 X 4.5 TW8 652 IVE 1 EA MORTISE EU LOCK M8859EU AE LXL 626 ACC 1 EA LEVER TRIM MATCH BUILDING STANDARD 626 C-R 1 EA MORTISE CYLINDER AS REQUIRED BY NARROW STILE LOCK MFR 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP REG OR PA AS REQ 689 LCN 1 EA FLOOR STOP FS439 682 IVE CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 GROUP NO. 34 1 EA PANIC HARDWARE AX-98-L-17 626 VON 1 EA RIM CYLINDER CR3080 CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R BALANCE OF HARDWARE EXISTING TO REMAIN GROUP NO. 35 2 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 652 IVE 1 EA EU STOREROOM LOCK CL33905 PZD 626 C-R 1 EA SURFACE CLOSER 4040XP 689 LCN 1 EA WALL STOP WS401/402CVX 626 IVE CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-22 DOOR HARDWARE GROUP NO. 36 2 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 652 IVE 1 EA EU MORTISE LOCK W/ INDICATOR XL13-346 L9492LEU 17A L583-363 XL13-346 RX DM CON 12/24 VDC 626 SCH 1 EA MORTISE CYLINDER CR1080 CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA SURFACE CLOSER 4040XP SCUSH 689 LCN REMOTE RELEASE - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 TURNING THUMBTURN SHUNTS POWER TO REMOTE RELEASE. GROUP NO. 37 6 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA CONST LATCHING BOLT FB51T 630 IVE 1 EA STOREROOM LOCK SET CLX3357 PZD CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA COORDINATOR COR X FL 628 IVE 2 EA MOUNTING BRACKET MB SP28 IVE 2 EA SURFACE CLOSER 4040XP CUSH 689 LCN 1 EA GASKETING 188SBK PSA BK ZER 1 EA ASTRAGAL 43STST OR BY HM DOOR MFR STST ZER GROUP NO. 38 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA PASSAGE SET CLX3310 PZD 626 C-R 1 EA SURFACE CLOSER 4040XP EDA 689 LCN 1 EA WALL STOP WS401/402CVX 626 IVE 1 EA GASKETING 188SBK PSA BK ZER City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-23 GROUP NO. G01 1 EA PANIC HARDWARE OUT-AX-98-L-17-WH 626 VON 1 EA RIM CYLINDER CR3080 CT6R 626 C-R BALANCE OF HARDWARE EXISTING TO REMAIN GROUP NO. H01 1 EA ELECTRIC HINGE 5BB1 TW8 - SIZE AND THICKNESS TO MATCH EXISTING 630 IVE 1 EA ELEC TRIM M996-L-RV-17-FSE 626 VON 1 EA SWITCH SWITCH KIT-RX VON CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 BALANCE OF HARDWARE EXISTING TO REMAIN GROUP NO. H02 2 EA PIVOT SET 7215 SET 626 IVE 2 EA INTERMEDIATE PIVOT 7215 INT 626 IVE 2 EA POWER TRANSFER EPT10 689 VON 1 EA ELEC PANIC HARDWARE RX-QELX-AX-3549A-EO-LBL 626 VON 1 EA ELEC PANIC HARDWARE RX-QELX-AX-3549A-NL-OP-388- LBL 626 VON 1 EA MORTISE CYLINDER CR1080 CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 2 EA 90 DEG OFFSET PULL 8190EZHD 10" O 630-316 IVE 1 EA SURF. AUTO OPERATOR 9553 REG2 LESS TRACK AS REQ (120/240 VAC) ANCLR LCN 4 EA ACTUATOR 4 X 4 - 3 630 WIK 1 EA BOLLARD SQ-5 PREPPED FOR HI/LO ACTUATOR AND CARD READER 630 WIK 1 SET SEAL SET WEATHERSTRIP BY DOOR/FRAME MANUFACTURER 2 EA DOOR SWEEP 39A A ZER 1 EA THRESHOLD PER DETAIL A ZER CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-24 DOOR HARDWARE GROUP NO. H03 2 EA PIVOT SET 7215 SET 626 IVE 2 EA POWER TRANSFER EPT10 689 VON 1 EA ELEC PANIC HARDWARE RX-QELX-AX-3549A-EO-LBL 626 VON 1 EA ELEC PANIC HARDWARE RX-QELX-AX-3549A-NL-OP-388- LBL 626 VON 1 EA RIM CYLINDER CR3080 CTLR 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 2 EA 90 DEG OFFSET PULL 8190EZHD 10" O 630-316 IVE 1 EA SURF. AUTO OPERATOR 9553 REG2 LESS TRACK AS REQ (120/240 VAC) ANCLR LCN 4 EA ACTUATOR 4 X 4 - 3 630 WIK 1 EA BOLLARD SQ-5 PREPPED FOR HI/LO ACTUATOR AND CARD READER 630 WIK 1 SET SEAL SET WEATHERSTRIP BY DOOR/FRAME MANUFACTURER 2 EA DOOR SWEEP 39A A ZER 1 EA THRESHOLD PER DETAIL A ZER CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 GROUP NO. H04 2 EA DOOR CORD 788C-18 WITH 20 GAUGE WIRES 626 SCE 1 EA ELEC PANIC HARDWARE RX-QELX-PA-AX-3549A-EO-LBL 626 VON 1 EA ELEC PANIC HARDWARE RX-QELX-PA-AX-3549A-NL-OP- 388-LBL-CON 626 VON 1 EA MORTISE CYLINDER CR1080 CT6R 626 C-R 1 EA RIM CYLINDER CR3080 CTLR 626 C-R 2 EA PERMANENT CORE CR8000 626 C-R 1 EA SURF. AUTO OPERATOR 9553 REG2 LESS TRACK AS REQ (120/240 VAC) ANCLR LCN 4 EA ACTUATOR 4 X 4 - 3 630 WIK 1 EA BOLLARD SQ-5 630 WIK 1 EA KEY SWITCH 653-1414 L2 12/24 VDC 630 SCE BALANCE OF HARDWARE EXISTING TO REMAIN EXIT DEVICES MUST BE MECHANICALLY DOGGED FOR AUTO OPERATOR TO OPEN DOORS. AUTO OPERATOR TO BE TURNED OFF VIA KEY SWITCH WHEN EXIT DEVICES ARE UNDOGGED. City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Allegion Group 4 Project No. 22575-01 May 07, 2025 DOOR HARDWARE 087100-25 GROUP NO. H05 1 EA PIVOT SET 7215 SET 626 IVE 1 EA POWER TRANSFER EPT10 689 VON 1 EA ELEC PANIC HARDWARE RX-QELX-AX-35A-T-360T-299 626 VON 2 EA MORTISE CYLINDER CR1080 CT6R 626 C-R 1 EA PERMANENT CORE CR8000 626 C-R 1 EA 90 DEG OFFSET PULL 8190EZHD 10" O 630-316 IVE 1 EA SURF. AUTO OPERATOR 9542 AS REQ (120/240 VAC) ANCLR LCN 4 EA ACTUATOR 4 X 4 - 3 630 WIK 1 SET SEAL SET WEATHERSTRIP BY DOOR/FRAME MANUFACTURER 1 EA DOOR SWEEP 39A A ZER 1 EA THRESHOLD PER DETAIL A ZER 1 EA KEY SWITCH 653-1414 L2 12/24 VDC 630 SCE AUTO OPERATOR, KEY SWITCH, ACTUATORS TO BE WIRED SO THAT THE OUTSIDE ACUATOR IS POWERED AND THE EXIT DEVICE IS ELECTRONICALLY DOGGED SIMULTANEOUSLY VIA KEYSWITCH. GROUP NO. H06 1 EA ELECTRIC HINGE 5BB1 TW8 - SIZE AND THICKNESS TO MATCH EXISTING 630 IVE 1 EA ELEC TRIM M996-L-RV-17-FSE 626 VON CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 BALANCE OF HARDWARE EXISTING TO REMAIN City of Santa Ana Public Library Renovation Allegion Group 4 Architecture Research + Planning, Inc. May 07, 2025 Group 4 Project No. 22575-01 087100-26 DOOR HARDWARE GROUP NO. H07 2 EA HINGE 5BB1 NRP - SIZE AND THICKNESS TO MATCH EXISTING 630 IVE 1 EA ELECTRIC HINGE 5BB1 TW8 - SIZE AND THICKNESS TO MATCH EXISTING 630 IVE 1 EA EU STOREROOM LOCK CLX33905 M92 PZD CT6R 626 C-R 1 EA SURFACE CLOSER 4040XP SCUSH 689 LCN 1 EA GASKETING 188SBK PSA BK ZER 1 EA DOOR SWEEP 39A A ZER 1 EA THRESHOLD PER DETAIL A ZER CARD READER - WORK OF DIVISION 28 CARD READER - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 POWER SUPPLY - WORK OF DIVISION 28 END OF SECTION City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Group 4 Project No. 22575-01 RFI #121 – April 16, 2025 OPERABLE PARTITIONS 10 2226-1 SECTION 10 2226 – OPERABLE PARTITIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SECTION INCLUDES A. Operable Partitions: Manually operated Electric, center stacking, top supported operable wall with panels hinged in groups of two for Community Room. 1.3 RELATED SECTIONS A. Section 05 1200 – Structural Steel Framing: Steel carrier beams for operable partition top track. 1.4 ACTION SUBMITTALS A. Product Data: Material descriptions, construction details, finishes, installation details, and operating instructions for each type of operable panel partition, component, and accessory specified. Included data on acoustical performance, surface-burning characteristics, and durability. B. Shop Drawings: Show location and extent of operable panel partitions. Include plans, elevations, sections, details, attachments to other construction and accessories. Indicate dimensions; weights; conditions at openings and for storage; and required installation, storage, and operating clearances. Indicate location and installation requirements for hardware and track, and direction of travel. Show blocking to be provided by others. Include the following: 1. Calculations: Calculate requirements for supporting operable panel partitions and verify capacity of carriers and track components to support loads; indicate deflection limits for partition and adjacent construction. C. Setting Drawings: For embedded items and cutouts required in other work, including support beam-punching template. D. Coordination Drawings: Reflected ceiling plans, drawn to scale, on which the following items are shown and coordinated with each other, based on input from installers of the items involved: 1. Suspended ceiling components. 2. Structural members to which suspension systems will be attached. 3. Size and location of initial access modules for acoustical tile. 4. Items penetrating finished ceiling, including the following: a. Lighting fixtures. b. HVAC ductwork, outlets, and inlets. c. HVAC controls. d. Interface with laser system, lighting and shading controls. e. Speakers. f. Sprinklers. City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. RFI #121 – April 16, 2025 Group 4 Project No. 22575-01 10 2226-2 OPERABLE PARTITIONS g. Smoke detectors. h. Access panels. i. Ceiling fans. E. Samples for Verification: For each type of exposed material, finish, covering, or facing indicated, prepared on Samples of size indicated below: 1. Textile: Full width by not less than 36-inch- (914-mm-) long section of fabric from dye lot to be used for the Work, with specified treatments applied. Show complete pattern repeat. 2. Panel Edge Material: Not less than 3 inches (75 mm) long. 1.5 INFORMATIONAL SUBMITTALS A. Submit acoustical test reports showing product conformance with ASTM E90 and ASTM C423. B. Seismic Qualification Certificates: For operable panel partitions, accessories, and components, from manufacturer. 1. Basis for Certification: Indicate whether withstand certification is based on actual test of assembled components or on calculation. 2. Dimensioned Outline Drawings of Equipment Unit: Identify center of gravity and locate and describe mounting and anchorage provisions. 3. Detailed description of equipment anchorage devices on which the certification is based and their installation requirements. C. Product Certificates: Submit letter signed by manufacturer certifying that operable walls to be furnished on this project comply with the requirements of the specification. D. Product Test Reports: From an independent testing agency indicating that each operable panel partition complies with requirements. Submit the following: 1. Report for STC. 2. Proof load testing of track/trolley/bracket/hanger rod assembly. 3. Other proof load tests as may be identified in 'PART 2 of this Section. E. Field Test Reports: Indicate and interpret test results for compliance with performance requirements. 1. The City reserves the right to field sound test the operable wall within 60 days of the date of Project Acceptance. Cost for field sound testing shall the responsibility of the City. 1.6 CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: For operable panel partitions to include in maintenance manuals. In addition to items specified in Division 1 Section "Operation and Maintenance Data," include the following: 1. Panel finish facings and finishes for exposed trim and accessories. Include precautions for cleaning materials and methods that could be detrimental to finishes and performance. 2. Seals, hardware, track, carriers, and other operating components. B. Warranty: Executed special warranty specified in this Section. City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Group 4 Project No. 22575-01 RFI #121 – April 16, 2025 OPERABLE PARTITIONS 10 2226-3 1.7 MAINTENANCE MATERIAL SUBMITTALS A. Furnish extra materials from the same production run that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. 1. Panel Finish-Facing Material: Furnish full width in quantity to cover both sides of two panels when installed. 1.8 QUALITY ASSURANCE A. Installer Qualifications: An experienced installer who is certified in writing by the operable wall manufacturer as qualified to install the manufacturer's partition system for work similar in material, design, and extent to that indicated for this project. B. Testing Agency Qualifications: An independent NVLAP-accredited testing laboratory with experience and capability to conduct the testing indicated, as documented according to ASTM E548. NVLAP-accredited laboratories must document accreditation, based on a ''Certificate of Accreditation'' and a ''Scope of Accreditation'' listing the test methods specified. C. Fire-Test-Response Characteristics: Provide panels with finishes meeting one of the following as determined by testing identical products by UL or another testing and inspecting agency acceptable to authorities having jurisdiction: 1. Surface-Burning Characteristics: As determined by testing per ASTM E84. a. Flame-Spread Index: 25 or less. b. Smoke-Developed Index: 450 or less. 2. Fire Growth Contribution: Textile wall coverings comply with the acceptance criteria of NFPA 265. D. Forest Certification: Provide components made with all wood products obtained from forests certified by an FSC-accredited certification body to comply with FSC STD-01-001, "FSC Principles and Criteria for Forest Stewardship." 1.9 DELIVERY, STORAGE, AND HANDLING A. Protectively package and sequence panels in order for installation. Clearly mark packages and panels with numbering system used on Shop Drawings. Do not use permanent markings on panels. B. Deliver materials in order as required by schedule for installation. C. Handle materials in accordance with manufacturer's instructions. 1.10 SITE CONDITIONS A. Field Measurements: Verify actual dimensions of operable panel partition openings by field measurements before fabrication. 1.11 WARRANTY A. Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of operable panel partitions that fail in materials, fabrication, or installation within specified warranty period. 1. Failures include, but are not limited to, the following: a. Faulty operation of operable panel partitions. City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. RFI #121 – April 16, 2025 Group 4 Project No. 22575-01 10 2226-4 OPERABLE PARTITIONS b. Deterioration of metals, metal finishes, and other materials beyond normal wear. 2. Warranty Period, Panels: Five years from date of Substantial Completion. 3. Warranty Period, Fixed Top Seals, Track, Carriers, and its Component Parts: Ten years from date of Substantial Completion. PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. Seismic Performance: Operable panel partitions shall withstand the effects of earthquake motions determined according to SEI/ASCE 7. 1. The term "withstand" means "the panels will remain in place without separation of any parts from the system when subjected to the seismic forces specified." B. Acoustical Performance: Provide operable panel partitions tested by a qualified testing agency for the following acoustical properties according to test methods indicated: 1. Sound-Transmission Requirements: Operable panel partition assembly tested for laboratory sound-transmission loss performance according to ASTM E90, determined by ASTM E413, and rated for not less than the STC indicated. 2. Noise-Reduction Requirements: Operable panel partition assembly, identical to partition tested for STC, tested for sound-absorption performance according to ASTM C423, and rated for not less than the NRC indicated. 3. STC: 52. 2.2 MANUFACTURERS A. Basis-of-Design Product: The design for the operable partition is based on the manufacturer identified below. Subject to compliance with requirements, provide the named product or a comparable product by one of the following: 1. Basis-of-Design: KWIK-WALL 3000 Series. 2. Advanced Equipment Corporation. 3. Modernfold, Inc. 4. Or approved equal. 2.3 PANELS A. Product: Manually operated, top-supported, flat panels hinged in pairs of two. 1. Panels shall be nominally 4” thick, of equal width, and continuously hinged. 2. Height: 9’-0”. 3. Panel faces shall be laminated to appropriate substrate to meet the STC requirement specified in Acoustical Performance Article herein. a. Face Material: Fabric Finish, gray. b. Horizontal Splice: None. 4. Frames shall be of 16 gauge painted galvannealed steel with integral factory applied aluminum vertical edge and face protection. Face finish shall wrap around the vertical panel edges and provide no protective vertical face trim. 5. Vertical sound seals shall be of tongue and groove configuration, ensure panel-to- panel alignment and prevent sound leaks between panels. 6. Horizontal top seals shall be fixed continuous contact dual 4-finger vinyl. 7. All standard panels shall have bottom retractable seals which provide a minimum of 2” floor clearance during movement of the partition, including all panels adjacent to pass door(s). City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Group 4 Project No. 22575-01 RFI #121 – April 16, 2025 OPERABLE PARTITIONS 10 2226-5 a. Retractable bottom floor seal to exert downward seal force when activated. Floating or rigid seals that maintain contact with the floor during partition movement will not be acceptable. 8. Optional: Bottom seals shall be fixed continuous contact 4-finger vinyl. 9. No floor mounted seal activators are allowed. 10. Panels must provide wall-to-wall contact for tight acoustical seal. Operable wall systems that do not extend to the back of storage pocket are not acceptable. B. Weight of the panels shall be 5.7-10.2 lbs. per sq. ft. based on options selected. C. Suspension System: 1. Track shall be structural aluminum. Track shall be supported by adjustable steel hanger brackets connected to structural support by pairs of 3/8-inch (9.5 mm) diameter threaded rods. a. Exposed track soffit: Track soffit to be integral to track shape and shall be powder-coated off-white paint finish. Track must accommodate termination of plenum sound barriers on both sides of track for maximum sound control. b. Carriers: One trolley per panel with 3-inch (76 mm) diameter glass-reinforced nylon all steel precision-ground ball-bearing wheels. Steel-wheeled or reinforced polymer trolleys on aluminum track not permitted. Trolleys shall attach to panels with 1/2-inch (13 mm) diameter pendent bolt mounted to welded steel mounting plate. D. Safety Requirements: 1. Low profile hinges shall be of steel and project no more than 1/4" (6) beyond panel faces. Panels to have a minimum of three hinges. 2. Each panel must be supported by a single carrier allowing the panels to stack freely without the use of rub rails near the pocket, thus decreasing the risk of injury while stacking into a pocket. 3. Partition shall be operated by two (2) control stations wired in series and located on opposite sides and ends of the partition. The key stations require human contact to be activated ensuring supervised operation of the partition system. E. Finishes 1. Face finish: Factory applied stain resistant fabric, upgraded from manufacturer’s standard selection. 2. Exposed metal trim and seal color: As selected by Architect from manufacturer’s standard colors. F. Accessories: 1. ADA compliant pass door meeting requirements indicated on Drawings, of the same thickness and construction as the basic panels. Pass door leaf has perimeter trim to protect face finish and to provide visual identification as required by California Building Code. 2. Finished end cover. 3. Recessed exit sign. 4. Lead panel with bulb seal. 5. Pocket doors. G. Pass Doors: Fabricated to comply with ADA requirements. Swinging single door built into and matching panel finish and thickness; complete with frames and operating hardware. Hinges finished to match other hardware. 1. Single Pass Door/s: 36 by 80 inches (914 by 2032 mm), provide with concealed door closer equipped with hold open device. 2. Hand pull on both sides of door. City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. RFI #121 – April 16, 2025 Group 4 Project No. 22575-01 10 2226-6 OPERABLE PARTITIONS 3. Panic hardware with or without locking lever handle. 4. Exit Sign: Provide above pass doors, flush mounted, self-illuminated. 2.4 OPERATION A. Panels are manually moved from the storage area, positioned in the opening, and seals set. B. Retractable Horizontal Seals: 1. Retractable horizontal seals shall be activated by a removable quickset operating handle located approximately 42” (1067) from the floor in the panel edge. Seal activation requires approximately 15 lbs. (6.8 kg) of force per panel and approximately a 190 degree turn of the removable handle. Top and bottom retractable seals on each panel shall be operated simultaneously. C. Automatic Floor Seals: 1. Horizontal seals shall be activated by pressing the edge of the panel into the edge of the adjacent panel or wall. 2. Seal activation requires approximately 15 lbs. (6.8 kg) of force per panel. D. Final partition closure: Expander mechanism with a nominal 5" [127] of travel, activated from the face of the panel using a removable wrench as supplied by manufacturer. The Expander Panel shall be equipped with an adjustable bottom seal. 2.5 ACOUSTICAL PERFORMANCE A. Acoustical performance shall be tested at a laboratory accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) and in accordance with ASTM E90 Test Standards. Standard panel construction shall have obtained an STC rating of 52 minimum. 2.6 PANEL CONSTRUCTION A. Operable Acoustical Panels: Operable acoustical panel partition system, including panels, seals, finish facing, suspension system, operators, and accessories. B. Panel Operation: Manually-operated, continuously-hinged panels. C. Panel Construction: Provide top reinforcement as required to support panel from suspension components and provide reinforcement for hardware attachment. Fabricate panels with tight hairline joints and concealed fasteners. Fabricate panels so finished in-place partition is rigid; level; plumb; aligned, with tight joints and uniform appearance; and free of bow, warp, twist, deformation, and surface and finish irregularities. D. Dimensions: Fabricate operable acoustical panel partitions to form an assembled system of dimensions indicated and verified by field measurements. 1. Panel Width: As indicated. E. Hardware: Manufacturer's standard as required to operate operable panel partition and accessories; with decorative, protective finish. 1. Hinges: Manufacturer's standard. 2. Exit Device: Manufacturer's standard. F. Hardware: Manufacturer's standard as required to operate operable panel partition and accessories; with decorative, protective finish to match panel trim finish. City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Group 4 Project No. 22575-01 RFI #121 – April 16, 2025 OPERABLE PARTITIONS 10 2226-7 2.7 SEALS A. General: Provide types of seals indicated that produce operable panel partitions complying with acoustical performance requirements and the following: 1. Manufacturer's standard seals. 2. Seals made from materials and in profiles that minimize sound leakage. 3. Seals fitting tight at contact surfaces and sealing continuously between adjacent panels and between operable panel partition perimeter and adjacent surfaces, when operable panel partition is extended and closed. B. Horizontal Top Seals: 1. Continuous-contact, extruded-PVC seal exerting uniform constant pressure on track. C. Vertical Seals: Deep-nesting, interlocking astragals mounted on each edge of panel, with continuous PVC acoustical seals. D. Top Seals: Panel top seals shall be fixed, flexible multi-fin. E. Horizontal Bottom Seals: PVC-faced, mechanical, retractable, constant-force-contact seal exerting uniform constant pressure on floor when extended, ensuring horizontal and vertical sealing and resisting panel movement. 1. Automatically Operated for Acoustical Panels: Extension and retraction of bottom seal automatically operated by movement of partition, with operating range not less than 2 inches (50 mm) between retracted seal and floor finish. 2.8 SUSPENSION SYSTEM A. Suspension Tracks: Aluminum with adjustable steel hanger rods for overhead support, designed for type of operation, size and weight of operable panel partitions as indicated. Size track to support partition operation and storage without damage to suspension system, operable panel partitions, or adjacent construction. Limit track deflection to no more than 0.10 inch between bracket supports. Provide a continuous system of track sections and accessories to accommodate configuration and layout indicated for partition operation and storage. 1. Model No.: 425 for Hinged Pairs of panels. B. Carriers: Trolley system as required for configuration type, size, and weight of partition and for easy operation; with ball-bearing wheels. C. Aluminum Finish: Mill finish or manufacturer's standard, factory-applied, decorative finish unless otherwise indicated. D. Steel Finish: Manufacturer's standard, factory-applied, corrosion-resistant, protective coating unless otherwise indicated. E. Proof Load Testing: Submit test report from nationally recognized independent laboratory showing that assembly of track/trolley/bracket/hanger rod sustains a load of 8,000 pounds at mid-point of 48-inch simple span. Load applied to trolley via pendant bolt. City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. RFI #121 – April 16, 2025 Group 4 Project No. 22575-01 10 2226-8 OPERABLE PARTITIONS PART 3 - EXECUTION 3.1 EXAMINATION A. Examine flooring, structural support, and opening, with installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of operable panel partitions. B. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. General: Comply with ASTM E557 except as otherwise required by operable panel partition manufacturer's written installation instructions. B. Install operable panel partitions and accessories after other finishing operations, including painting, have been completed. C. Install panels from marked packages in numbered sequence indicated on Shop Drawings. D. Broken, cracked, chipped, deformed, or unmatched panels are not acceptable. E. Broken, cracked, deformed, or unmatched gasketing or gasketing with gaps at butted ends is not acceptable. 3.3 FIELD QUALITY CONTROL A. Optional Testing: City reserves the right to field sound test partition installation within 60 days of installation. City Representative shall engage a qualified, professional, acoustical engineer to perform field tests and to prepare test reports. Cost of the field sound tests shall be responsibility of the City. B. Testing Methodology: Perform testing of installed operable panel partition for noise isolation according to ASTM E336, determined by ASTM E413, and rated for not less than STC indicated. Adjust and fit partitions to comply with STC test method requirements. C. Repair or replace operable panel partitions that do not comply with requirements. 1. Should operable panel partitions fail to achieve the specified STC, partition supplier shall make corrections/adjustments and pay for the cost of retesting. 2. In the event that the specified STC is not achieved after corrections/adjustments and retesting and the partition supplier has not been able to demonstrate that flanking sound through the surrounding building construction is the cause for failure then the partition supplier, at its own cost, shall replace the operable partition with a new partition that is capable of achieving the specified STC and pay for the cost of field sound testing this partition installation. D. Prepare written test and inspection reports and submit to the City Representative. 3.4 ADJUSTING A. Adjust operable panel partitions to operate smoothly, easily, and quietly, free from binding, warp, excessive deflection, distortion, nonalignment, misplacement, disruption, or malfunctioning, throughout entire operational range. Lubricate hardware and other moving parts as indicated by wall manufacturer. City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. Group 4 Project No. 22575-01 RFI #121 – April 16, 2025 OPERABLE PARTITIONS 10 2226-9 B. Adjust storage pocket doors to operate smoothly and easily, without binding or warping. Check and readjust operating hardware. Confirm that latches and locks engage accurately and securely without forcing or binding. 3.5 CLEANING A. Clean soiled surfaces on completing installation of operable panel partitions, to remove dust, adhesives, and other foreign materials according to manufacturer's written instructions. B. Provide final protection and maintain conditions, in a manner acceptable to manufacturer and Installer that ensure operable panel partitions are without damage or deterioration at time of Substantial Completion. C. Replace panels that cannot be cleaned and/or repaired, in a manner approved by Architect, before time of Substantial Completion. D. Construction Waste Management: Manage construction waste in accordance with provisions of Section 01 7419 Construction Waste Management and Disposal. 3.6 DEMONSTRATION A. Engage a factory-authorized service representative to train City's maintenance personnel to adjust, operate, and maintain operable panel partitions. 1. Test and adjust seals, hardware, carriers, tracks, pass doors, pocket doors, controls, safety devices and other operable wall components. Replace damaged or malfunctioning operable components. 2. Train City's maintenance personnel on procedures and schedules for servicing and maintaining equipment and schedules. 3. Review data in maintenance manuals. END OF SECTION 10 2226 City of Santa Ana Public Library Renovation Group 4 Architecture Research + Planning, Inc. RFI #121 – April 16, 2025 Group 4 Project No. 22575-01 10 2226-10 OPERABLE PARTITIONS This Page Intentionally Left Blank