HomeMy WebLinkAbout10195812 - PermitE
Project Address: 2601 N Laird St
Assessor's Parcel 399-154-07 Lot: 54
Unit Bldg: Address Range:Suite Range:
Zoning: RlBlock: NA Itacl:2419 Hrstoric No
city of Santa Ana 20 Civic Center Plaza (M-'19), Santa Ana, CA,27O2 Building
Permit Counter: (714) 647-5800 lnspection Requests: (714) 667-2738 lnspector Section: (714) 647-5853
Permit #: I Ol95812
Pin #: 58019
Building Use:
Job Type:
Nature of Work:
Existing Bldg. & Use
Proposed Use:
Single Family Dwelling
Solar
Solar
Sfd Wdet garago
R-3, U
VB
cBc 2016
x-0602320144J
'l st FL Area
2nd FL Area
Other Areas
Garage Area
Total
Patio:
T.l.Area:
Yards Req'd
Valuation: S4,000.00
Occupancy:
Constr Type
Code:
Flood Zone:
# of Stories:
Description of Work: lnstall new 2.40 kw roof mounted solar PV system (8 panels) Per PV checklist
Planning Conditions:
Botchi:426510lficer (:TYH
ID! NGARC IAlof?
1r.r 195912,.?
3/8/2r'l I g
IrRns+: 62
Rel+:
Engineer
Address
Tronsoct ion Totol
50uth tiest Sun Solor' InL,
t626.i?
Owner:
Address
Phone:
Tenant
De Pham
2601 N Laird St
Santa Ana, CA 927061224
(714) 7504030
Contractor: South West Sun Solar, lnc.
Address: 13752 Harbor Blvd
Garden Grove, CA 92843
Phone: (714) 582-3909
State Lic #: 1004667
Lic Type: C-10
Bus. Lic #: 350754
Workers' Compensation lnsurance
Carrier: COMMERCE & INDUSTRY INSURA
Poiicy #: 033571255
Expires: 0610'112018
Bu i Id ins
t_t1 1 16(t(t2- :;16010t-rt-
BIdg Stds kevo I v ine
r.tl 1160(12- 5161200tr-
V iso
(:(:+ : *r*****r*r *r872,(
_ 150r.1. (nj
t1 .00
t626 ,12
Auth+:01(t?:iG
Phone:
License #
Architect /
Desiqner:
Address:
Phone:
License #
Zuniga. Alliss
Dalel
Date:
Date: 03/08/2018
Subject to Field:
M
Misc. Receipt
Misc. Receipl
Misc. Receipt
07776002 51501 Permit Fee
07776002 57672 81d9. Stds. Revolving
07776002 57600 cenetal Plan Update
$500.00
$1.00
$0.00
No
No
No
No
Fire lnsp Req'd:
Police lnsp. Req'd
No
No Account#Tota I
Flood Zone Cerl Req'd: No 01116002 51601
Every pomit issued shall becono invalid unless the wo* on the site authonzed by
such peinit is commenced within 180 days aftot its issuance,ot iflhe wo* aulhotized
on the site by such pemil is suspended ot abandoned for a penod o1180 days aftet
the tirno the wotu is commsnced
lnspector MID#: 2018-141978
01 1 16002 51612
$500 00
$1.00
Fee Total
Paid to Oate:
Balance Due:
$501 00
$0.00
$501 .00
Planning Approval By
Plan Checked By:
Permit lssued By:
NPDES lnsp. Req'd:
PWA lnsp Req'd:
Planning lnsp. Req'd:
Landscaping lnsp. Req'd
DATE ID/SIG.COMMENTS OWN}:R BTJILDEI' DI:I,CARATION
I hd.try artrii un& Frry ol Fjury rh,r I m crcnfl 6oi rh. (blnradoB t-i:@ Irw rorrh. follo$i,8..a,.lsa70.rI5
UuJns !d Proasion (irj.) Any (-ry or Coudt shth r.qntr6 d Fmn lo oddd. s. inFo\e &mlislt or Ep6r rh .
'l4doe Fnr ", '1r isM.. i\o rcquB rh.4dEd lor $cfi Fn lo filc. nsn d ndoEr rhd tE oi nE i licar.n p!m{n
Io lh. r,orisioN oflh. Contarors Li.avn lj* (( hrptr 9, Conhocins s h s.ction 7000 oaD,vt$.I oarh. tlBinds .nd
Itot srnrN Cod€) or lh.l IE or $. is .!mF rhcrdrom od rh. hdri! for rh. alL*.n.(nllrion An, violdion ofscclion')0! 1.5 t'y dnj
q,ph.mr for r Fn'r rbjdr rrE rrrlicet nr !cirilp.nrlrlof mr m{. rha nrc hun&.d (lrlls(ism}
l, &\ osns of I h. rroFny. or Dy .mrk,rc wirn war6 a rh.ir en. mnrpdsnon. $ ill d. rh. tro* dd 0E slrrlw i< n{
iddr,al or o lIs<rl aor idl. ( S( 70.14, BurinB md tto li<rcB Codc llr Contrky r Licmr lis &6 nor .rply k d o\ n6 of
rh.ImF! * b hILl o, ur{mrc rlEoa ,ri *ho &a exh *o{ h'lMlf o. h6-lf or rh^ru*t tir d hd o*n .hphr6.
Forilnl rhd $ch mFo1ffi G mt dd'd.i or.fidrd fo. sL l[ ho$6r, rlr hilditB n in{"*._-od 6 $ld $inm om j6
ofcorr{ rF( $. o$E lrlitb *ill haE lh. tudo orfm\ilts $i hc s5. dij d hild or itr{roc.lh. IroF} fd th.,nq$Eo,
l. E o$fr orrhc Frpdr, m dcluir.ly ro rrluB r h ltaGj.odracioR b.onrrucr ilr Fojci (lir 7or-l- &8'6
!d ltl'bsin ( o&: Th. ConrrIlois Lic€M L.* dc mr @lt r. D0$.6 of Fopa!' $h. b{iktr or inrove rtd(n.
md who Nnrds for !u.h Fojd3 $irh i ( odrado(3) li.sEqj puBuln ro rh. (i'nrr.cu r l-icc@ lr$,
I M.rmr, uto:L. sdri,n
Drr.: Ornc:
1loRkriis-con, Pirlta^ rxrN
IECI,A8^IIOI
I lE.tD .ili'n uid.r Fsxl of Fl!4 oft oarh. folh*n's &dsdirtri
I hrv. drkl *rll ,nrimrn ! ( d ia,.d. of (i\.sr ro S.ll lctrr€ to M,k6' .on:Fsdrn. N Fovdcd for by Srtun r 7(tu orrh.
Il&tr (id., for rh. Ffonnk--. d r rh. so* ntrwhichth.psnil ir L$u.d
Vl h.rcand\illn.F ain *.rt6 conFErion iMr, ..6 r.rtutra! b sGib. !?0oofrh.libo, (ir!., for ih. Flnmm. ol
rh. $o,t fo. *hich lhis p.tr is isuqj My trorkG .onFMion iNurMc. .nid rd Brh(y numb6 r.:
cuF I TTG- 071 -{ 7 - 1'2,( .o ,.or*,' l:16
I c.niithd inlh.pcf{runccof lh. so fo. *hi(h lhls p6nit Lt N!cd, I shlll not oploy any p..$r in any men(
s e ro bdoc ubj.t lo llE *nr6 @.rra!d6n lrst orcdifo@ !d qr rhri ,t l lrnukt h.(r lutrar ro rtr
sortd' snp.,srb. prst si(rc oasdkn .! 700 of rb. lihor Cod.. I ttLll fonhsnh lripry I'irh rbos F.r s.a
W ,ININC l'rilurc to *@ *ork6 comFcsrion covdag. ii uihwtuL Md shall subF d aploF ro aimin.l lEDftis sd
civil nncs up to on. hun.lr.! thousnd d.llds (lllrrr mr€MIion. .hnuscs ss r,(triddl tor lhc
sdr0n t076 0f rh. l itrr ( fri. inr6d .'ri
DECIJEAIIOB
I hdtb .rm uftr6 pd[l.lt of Fjur_v rld I m lkas] orld Frldon ol CnrFd 9 (offirrj $ nh Sdion 70()(] ) of Ur Bion !
ol rh. B6ilB,.d kof6ioB cod.. dj ny licde i! E tuU loc di.lfd
.n,*,r'^< (-1C /oo t67
7? (Y
CONSTNUCIION I r^TnIAG CEACY
I h6tt, rrm uBr6 FuXy of Fju J.. r hn rhd. ir ! @dru.rior lsxhls lsdy for rlr Frotu. of rh. *sr for *n.h rh6 Fni !
isu.d (s*.1097, crv. c.)
aftu(aNl-lc(Jlaara!
I h.dy lfm unld d!rh, of Fiury orc ol
'h.
followin! d.<lErioN
DnRnndn Pd'r}&b6r$ Ndlin. ntr r.<brl R.suhlnB(Tnk {0. Pan6}
Rqu&d l.rrd oaNotiiulr,.
I cdir\ rhd rlE f.d..rl reuL'irN Errdin8 ab.snB.dord d. d spplf,rbL
'o
rhi rroF
lc.1r lv rh.r I h (rcadlh'\ il) (alio tr:u \rarcrliirr1rd\trc rnlnrnrrbn Ncnr'(r I alre lo.o'nply s(h rll( 'ryand
( fLnly
ordinacs afll Slat. l!*s Eldi.8 lo .,rl hs.t_ .ulhrn. (FB.r'lalir6 of rhis Cil, and CouDly t! drq upon lll
ab!. mrion n t'nrFnJ for
ApDli.itrl or.\r.tr1 shnnltr L+ -tZ
Set Backs
Forms/Steel/Holdowns
Erection Pads
UFER Ground
SLAB Floor
Subf loor/VenUl nsulation
Roof Shealhing
Shear Wall
Framing
lnsulation/Energy
Dtywall I I/Ext.4nt. Lath laltb r\UttL bY-frown Coat I I (
Itrla so n ry
Pool Fence
T-Bar
Handicap Req
Deputy Final Report
E Final Reportrnee r
Flood Zone Certif
FINAL \l,i\\g u4t0\)
Certificate of Occu pancy
Notes, Remarks, Etc IM.l,v oV q r3 lb
I
BUILDING. INSPECTOR RECORD
SITE.WORK
I
I
I
I
I
I
*,,SANTA
NA,"Tffi
Planning E Bullding Agency
Building Satoty Divislon
20 Clvlc Csnter Plaza
P.O. Box '1988 (M-19)
Santa Ana, CA 92702
(714) 547.5800
www.santa-ana.org
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
sol-01 CBC 2013
Solar Photovoltaic (PV) Checktist for Detached STNGLE FAMtLy RESTDENCES Onty
lnslructlons: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO s ets of plans, of
minimum '11" x 17" size. lf answo rinq NO to anv of the ouestions. Dlan check shall be re q u ired.
Project Adarees; 2601 LAIRD ST' SANTA ANA, CA 92706
Contractor Company Name:
Contractor License Number:
SOUTHWEST SUN SOLAR, INC
1004667
YES NO Ai6 the following appllcable to the propossd project?
Will the PV system layout provide the rsquired three-foot wide clear access pathways
per Section 605.1 1 of tho Califomia Fire Code, and is this shown on the roof plan?
Will the PV system bs installed on a roof having only one roofing layer with no
overjays?
Will the PV anay be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of th6 roof?
Will the PV system weigh maximum 4 pounds per square feet or less?
Will ths PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
Will the PV system be inslallod with a space of 2" minimum to 10" maximum between
the underside o, modules and the surfacs of the roof?
Will the PV system be installed without using any balast system or counter-weight
sYStem?
Will the anchors bs installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
Will the minimum 5/16" lag screws bs installed with a minimum of 2-112 inch
embedmsnt into roof raners (with pre-drilled holes) and is this minimum embedment
shown on the plans?
Are ALL the structural pages of the plans WET stamped and signed by a California
a tr
Ettr
I tso
10 Efl
licensed professional engineer? (including project specific site plan, PV I
anchorage spacing, anchorage details and manufaclurs/s pV suppo rmation.)
I certify under penalty ot periury undor the laws ot lhe State of California that bove is true:
4
5
2
3
6
7
I
trD
Eto
Etr
Ettr
Etr
ao
pr;61 x3mg. TRANG CONG PHAM
phone Number: 7'14 582 3909
Signature
Date:
Emait Address: PERMIT
Rev:811712O15
@SoUTHWESTSUNSOLAR.COM
e
2 /E
EXPEDITED PERMIT PROCESS FOR PV SYSTTII.S
MICRO_INVERTER
The Solar America Board for Codes and Sundards (Solar ABCS) Expedited permit pro-
cess provides a means ro differentiate sysrems that can be permitted quickly and easily
due to their similarity with the majoriry of small-scale PV systems. Those sysrems with
unique characteristics may be handled with small addirions to rhis Expedited permit
Process or may require much more information, depending on the uniqueness of the
installation.
The following pages contain forms for the Micro-lnvener ro use with the Expedired Per-
mit Process. The Standard Srring, AC Module. and Supply-Side Connection forms
are also available as interacrive PDF files at ww\,v.solarabcs.org/permitting. In jurisdic-
tions that have adopted the Expedited Permit Process for PV Systems. rhese forms can
be filled out electronically and submitted in either prinred form and via email. An elec-
tronic format is used so thar rhe supplied informarion is srandardized and legible for the
local jurisdicrion.
R D
llAR 08 2018
City of Santa Ana
1olt6 5;1-lstr
ECEIVE
EXPEDITED PERMI-T PROClSS FOR PV SYSTEMS - MICRO-INVIRTER
I
I
. EXPEDITED PERMIT PROCESS FOR SMALL.SCALE I'V SYSTIN45
MICRO_INVERTER
The information in rhis guideline is inrended to help local jurisdicrions and conrracrors idenriry when PV system insallations
are simple. needing only a basic review and when an installation is more complex. It is likely that 50 % -75% of all residential
systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been
suggested to provide as a path to permit approval.
Requireil InJormation for Permit:
l. Site plan showing location of ma.;or componenrs on the propeny. This drawing need not be exactly to scale, but r(
should represenr relative location of componenrs at sire (see supplied example site plan). Pv arrays on dwellings
with a 3 perimerer space at ridge and sides may not need separare hre service review
2. Electrical diagram showing PV array conhguration, wiring sysrem, overcurrent protection, invertet disconnects,
required signs, and ac connection to building (see supplied srandard electrical diagram).
3. specificarion sheets and insrallarion manuals (if available) for all manufactured components including. but not
Iimired ro. PV modules. inverter(s). combiner box. disconnec(s. and mounting system.
Step 1 : Structural Review o[ PV Array Mounting System
Is tlre array to be mounled on a dehned, permitted mof structure? EYes ENo
IJ No due to non-compbant rooJ or a ground mount, submit completed worhsheet Jor the structure wKS L
Roof InJofination:
l. Is the roofing rype lighNeight (Yes = composition. lightweight masonry metal, erc. .)Yes
If No, submit completed worhsheetlor rooJ structure WKSI (No = heavy masonry, slate, etc...)
2. Does the roof have a single roof covenngi Eyes Eno
IJ No, submit completed worhsheetfor roof stucture WKSI.
3. Provide method and rype of wearherproohng roof penetrations (e.9. nashing, caulk)Flashing
t I ounting Sy st em I nJo nnation :
l. ls the mounting strucure an elgrneered product designed ro mount PV modules with no more ahan an 18" gap
beneath the module frames? EJves Euo
II No, prwidc details ol structural attachment certiled W a design professional.
2. For manufactured mounting sysrems. hll out information on rhe mounting system below:
a Mounting Sysaem Manufacturer SWH Product N ame and Model#Solar Mount
b Toral weichr of PV Modules and Rarls 368 lbs
c. Total Number of Attachment Pornts 18
d. Weighr per Atrachment Point (b + c)20.44 lbs (if greater than 45 lbs, see WKSI)
e. Maximum Spacing Between Attachment Poin(s on a Rail inches (see product manual for
maxrmum spacing allowed based on maximum design wind speed)
f. Total Surface Area of PV Modules (square feet)141 19 ft2
g. Distribured weight of Pv Module on Roof (b + 0 2.61 lbs/ft'z
IJ distributed weght of the Pv ststem is geater than 5 lbstf , see WKSI .
Step 2: Electrical Review o[ PV System (Calculations for Electrical Diagram)
ln order for a PV s!6tem to be considercd for an expedited permit pocess, the following must apply:
l. PV modules, utiliry-interactive inveners, and combiner boxes are identihed for use in PV systems.
2. The Pv array is composed of 4 series strings or less per inverter
3. The total inverrer capacity has a conrinuous ac power output 15,440 watts or less
4. The ac interconnection point is on the load side of service disconnecring means (690.64(8)).
5. One of the sBndard electrical diagrams (E l.l. El.I a, E l lb. or E l.lc) can be used ro accurately represent the PV
sysrem. lnteractive PDF diagrams are available ar www solarabcs.org/permifting.
I-'ill out the standard electrical diogram completely. A guide to the electrical diagrsm is provided to help the L\)plicdtlt
uiderstand each blank to jll in. If the electrical systetn is more conplex than the standard etectrical diagrati ./.tn effecti |t lt
cotnmunicqte, provide an alternative diagram with aryropriate detail.
2 EXPEDITED PERMIT I'IIOCESS TOR IV SYSTEMS - MICRO.INVTIU I'IT
PROPERTY LINE
--
r---,
I
SHED
4'-]l._
SHED
5
5
/
-i..
qG
I
4.-6
ooriiFei
PV-02
Prop€rty Layout
S6b 3ri2" - 1'
2
o
o'
t!
.H
T E 96d E 3fB : F;
6
3
EE5.3
fris3g
lssli
oc
o
oa
c
=a
o
0)3E)o
@
I
3
iE
E,*
q.{l
t rcperylveq
LEGEID I
tMnMEin Etec-trical Servic€ Pan€t I
EAC Oisconnocl I
lllMlnv€rter I
SIESub PanouEl6ctncal Load Conter I
XEcombin6r BorP8nolboard I
ErcPaD€lboard For Solar Only
IEExisting Sol6r Equipmont I
MICRO- I NVERTER ELECTRICAL DIAG RAM
2
F
co
Uo
c-
F
:
a-
Lo
One-Line Standard Electrical Diagram
for Micro-lnverter PV Systems
SOUTBWEST SIJN SOT-AR NC
I 3752 H REOR BLVI)
G^ROEN GROVE, CA 92843
Site Name: w NoarRrNH
Site Address:219 S BA(ER ST. SANTA ANA. CAe27o3
System AC Size: 3.60
NIS
o EQUIPM'NT SCHEOL]LE
TAG DESCRIPTION PART NUMBER I NOIES
I rnlu sor-rn -rs+ooocro1nl
I E ptr-. la6+x-us(ra$l)
l^r.,.3R
-
I
2
TPv Dc * ac MoDTJLE
]Dc/Ac TNVERTER oacRo)
E"9r,arj."Ll UTILITY
SERVtCt
I5AC COMB PANEL (rF USEO)
6 GEN METER (F USED)
8
AC OTSCONNECT (rF USEO)Sqd6 D 30.mp OU221RB / 5o.ht OU222RB NEIVIA 3R
ISERVTCE
PANEL
SEE GUIOE APPENDIX D FOR
INFORMATION ON MODULE ANO
ARRAY GROUNDING
MICRO.INVERTERS
IN BRANCH-
CIRCUIT
BUILDING
GROUNDING
ELECTRODE
MICRO.INVERTERS
IN ERANCH.
CIRCUIT
t---
FOR UNUSED MODULES
PUT 'N/A' in ALANK ABOVE
A
OESCRIPTION OR CONOUCTOR TYPE COND,
GAUGE
usE"tr* PVr,/rREr - Turo
GEC I EGC D X ALL THAT APPLY
EXTERIOR CABLE LISTED w/ INV MFG
THWI+2 O or XHHW-2 O o. RHW-2 tr i
GEC r EGC D X er-L lXll lpplVlt-
NO DC GEC IF 690,35 SYSTEM
rnwuz O-or xxnw-z O a Rnw-2 g I
GEC D EGC D X ALL THAT APPLY
NUMAER OF
CONDUCTORS
irFg_c"!19
MFG C"bl"
CONDUIT CONDUIT
ryPE SIZEtq t*4
SAME SAME
T
5
MO0 MOO MOO
DC
AC DISCO
r Box
)
INVERTER
OCPD
MOD MOO
E
DC oc
SAME SAME
I
1
2 M
MOO
i
I
A AA
A
CONDUIT AND CONDUCTOR SCHEOULE
3
NOTES FOR MICRO-INVERTER ELEC-TRICAL DIACRAM
:
F
,.)
cd
F
ad
a-
o
=o
I
Notes for One-Line Standard Electrical
Diaoram for Sinole-Phase PV SystemsSOUTHWEST SUN SOT-AR NC
13752 8ARBOR BIVO
GARD€N GROVE CA 923'3
Site Nam€: DE PHAM
S ite AddfgSS: 260 1 L rRo sr saNTA aNA cA 92706
System AC Size: 2.40
NIS
SIGNS-SEE GUIDT SICTION 7
OCPD = OVERCURRENT PROTECTION DEVICE
INVERTER RAIINGS (Guide Section 4)
INV€RTfA MOOEI r06-60-s-us (240v)
MAX OC VOLT RATING 48
POWER @ 4o'C
NOMINAL AC VOLTAGE
SIGN FOR DC DISCONNFCI
PV MOoUtt RATINGS @ STC lcuide Section 5)
Moourr MA(r TRINA SOLAR
MOOUTE MODEL
] uu powEn-ponrr cunnslrr {r,")
MAX POWER.POINT VOLTAGE (V!P)
TSM-300DD05A.08([
NATToNAL ELEcrRrca coDE REFERENCES
sHowN AS (rvEc )oo(.x,
No sign nocessary sinc€ 690.51
marking on PV modulo covers
neoded information
SIGN FOR INVERTER OCPD AND AC
DTSCONNECT (tF USEO)OPEN4IRCUIT VOLTAGE (VE)
I sroarc,ncu,r cu^n:*. 1,*1
] u* ar",aa ,ra= (o"rr)
19.191_
r32 5l__
139.9
ls64 I t SOLAR PV SYSTEM
AC POINT OF CONNECTION
l
15
300
,600
.1 '12
7.68- - l
ACOUTPUT CURiENI
MAXIMUM POWER (PUd)
MAX VOLTAGE (TYP 6OOV@)
Voc TEMP coEFF (mvfco or 9rfc tr)
IF COEFF SUPPLIED, CIRCLE UNIIS
MAX AC CURRENT
MAX OCPD RATING
1240
P!
0.96
t,u
NOMINAI AC VOTTAG E 240V
1 ) LOWEST EXPECf AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN
EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
IiISTALLATION LOCATION LOWEST EXPECTEOAMBIENT TEMP 'O
.C
2 ) HIGHEST CONTINUOUS AMBIENT TEMPERATURE AASED ON ASHRAE HIGHEST
MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALI.ATIoN LocATIoN, HIGHEST coNTINUoUS TEMPERATURE 6L"C
2 ) 2OO9 ASHRAE FUNDAMENTALS 2% DESIGN TEMPEMTURFS DO NOT EXCEED
47'C IN THE UNITED STATES (PALM SPRINGS, CA IS 44 IOC) FOR T ESS THAN 9
CURRENT{ARRYING CONDUCTORS IN ROOF'MOUNTEO SUNLIT CONDUIT AT
LEAST 0,5'ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF
47"C OR LESS (ALL OF UNITED STATES),
s) 12 AWG, 90'C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES
WITH lsc OF 7.6a AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER
FUSE,
b) 1O AWG, gO"C CONDUCTORS ARE GENERALLY ACCEPTABLF FOR MODUI FS
WllH lsc OF I6 AMPS OR LESS wHFN PROTECTEO BY A t'AMP OR SMALLER
FUSE
THIS PANEL FED BY MULTIPLE
SOURCES (UTILITY AND SOLAR)
NOTES FOR INVERTER CIRCUITS (Guid6 Section 8 and 9)
1)rF UTtLrrY REOUTRES A VTSTBLE-BREAK SWITCH. DOES TH|S SWTTCH MEET THE
REOUIREMENT? YESo NOD T.I/A tr
2) IF GENERATION METER REOUIRED. OOES THIS METER SOCKET MEET THE
REQUIREMENT? YES O NOtr N/A O
3) SIZE PHOTOVOLTAIC POWER SOURCE (OC) CONOUCTORS BASEO ON MAX
CURRENT oN NEc 69o.s3 srGN oR ocpD AAitNG AT DrscoNNEcr
4)SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER
OCPD AMPERE RATING. (Soo Guld6 Ss€don 9)
5) IOTAL OF INVERTER OUTPUT CIRCUIT OCPD(3), ONE FOR EACH MICRG
INVERTER cIFCUTT_ DoEs ToTAL SUPPLY aREAKERS coMPLY WITH 120% aUsaAR
ExcEPTloN lN 690.64(a)(2)(a)? YEsO NoD
I
NoTES FOR ARRAY clRcUlT WIRING (Guido Soctron 6 and 8 and Appondix E)
l
I
NOTES FOR ALL DRAWNGS:
Enphase
I