Loading...
HomeMy WebLinkAbout10180972_2725 N. BRISTOL - PlanA) Planning & Building Agency guilding and Safety Division !0 Civic Center Plaza '.0. Box 1988 (M-19)ELECTRICAL SIGN ianta Ana, CA 92702 714) 647-5800 REQUIREMENTS vww. santa-ana.orq % I- Code references are to the 2010 California Electrical Code (CEC) All signs require Planning Department approval. All electrical signs require electric plancheck and permit. 1. Manufacturer's instructions are required at the time of submittal. C-11: 3-21-2011 2. Submit detailed installation instructions including diagrams to the Building Department for plan review at the time of submittal. Plans must include appropriate items noted by this bulletin. 3. Cash or surety bond in the amount of $200.00 is required at time of issuance for each address. The cash or surety bond will be refunded after all required finals. A building permit is also required - except for open or highlight neon lighting. Installation Requirements: CONTACT FIELD INSPECTOR PRIOR TO SIGN INSTALLATION. (SEE SECTION G OF THIS BULLETIN) 1. Conductors and equipment shall comply with California Electric Code Article 600. 2. All metal parts of a sign shall be bonded in the manner specified in Article 250. Isolated metal parts are permitted to be bonded by using an external green insulated conductor. Equipment grounding & bonding conductors must be sized by 110.26 and protected from physical damage. Minimum size is 14 AWG. CEC 600.7 3. A listed disconnect switch in the power supply primary, shall be installed within sight of sign or have permanently installed means for locking in an "OFF" position. This is also true for a transformer enclosure. CEC 600.6 4. A listed receptacle or an approved termination device shall be used for each neon electrode. To relieve stress at terminations, tubing shall be supported with listed tube supports in an approved manner within six inches of electrode connection. CEC 600.41 & 600.42 5. Every electric sign of any type shall be listed by an approved testing laboratory and shall be installed in conformance with this listing. That includes "1 of x", "2 of x" labeling for each separate unit of a multi-unit sign. CEC 600.3 6. All "can" letters and transformers housings shall have section labels that are readily visible after installation. CEC 600.4 7. Transformers shall be located where accessible and be securely fastened in place. Page 1 of 2 When not inside the sign, they need a 3 foot high x 3 foot wide x 3 foot deep workspace. Transformers are permitted to be located in attics or canopies provided there is a passageway at least 3 feet high x 2 feet wide with a minimum 12 inch catwalk/walkway from the point of entry. Transformers must be securely fastened and independent of T- bar when above a suspended ceiling. No part of sign mav be fed with flexible cord when located above T-bar ceilings. CEC 600.21(E&F) & 400.8 8. Adequate illumination shall be provided for all working spaces about electrical equipment. This applies to attics and canopies when entry is required to service or inspect the equipment. At least one switch is required at entrance. CEC 110.34 & 600.21 9. Doorway to an attic or canopy space shall be minimum 3 feet by 2 feet wide. CEC 600.21(E) E. Open neon outline or highlight lighting. 1. To be treated as a sign by this department. However, Section D-5 & D-6 of this bulletin will not apply. 2. Neon tubing shall be located where not normally exposed to physical damage. Open neon tubing below 9 feet shall be protected from physical damage by an approved shielding method. CEC 600.30 and 1 10.34(E) F. Light-Emitting Diode (LED) Signs 1. Will be treated as a sign by this department. All sign rules in sections A, B, C, D, F, and G will apply as appropriate. 2. LED illumination for signage must be a listed or recognized component. Many LED manufacturers specify particular brands and models of transformers some do not. Manufacturer information to clarify this issue is required on LED sign plans. 3. Unlisted LEDs may not be used in an electrical sign or as permanently installed illumination. 11.0.3 4. Please have packaging or catalog cut-sheets on hand for inspector to review when LED modules do not bear listing symbols. G. Inspections 1. Contact an Electrical Inspector one (1) workday (minimum) in advance of installation to arrange a site meeting on dav of installation. 2. Call for inspection Monday through Friday, 8:00- 8:30 a.m. at (714) 647-5821. Approved prints and the job card must be on site for inspection. Page 2 of 2 .j LED Modules Specifications Model Item No. Intended Applications Available Colors Dimensions (lxWxH) # LED Bulbs / Module # Modules per ft. Power Consumption per module Power Consumption per ft. *Modules per 60W power supply -Lumen per Module -Lumen per Foot -Lumen Efficaq(Lm/w) Input Voltage Viewing Angle Operating Temperature Housing Wire Waterproof Rating Application Method Warranty Cenifications° DdraED Medium DuraLED Shon DLM3KDLM3RGB ,DLSZW, DISZR, DLSZG, DLS2B Standard'*nnel Lett4 Na,row Channel Letters Pure White (001<),08 Pure White (8500k), Red, Green, Blue 2.60° x 0.59' ¥811 1.500 x 0.47" x.28" 3x High BrigesN,mps 2x High Brightness Lamps 2/\ 3 O.725/0.48W 1.44W A modules (37ft)111 modules (3710 47.7 Im 95.4 Im / ft 66.3 lumens /watt 12V DC 120° -30°C - 70°C / -22°F - 158©F ABS slyrene copolymer AWG18,1007 IP68: dry, damp, and wet locations Double-sided tape 4-Year Umited Warranty UL Recognized (SAM) for US & Canada, CE *At 85% load capacity wider <113 1 Operating Temperature using a standard 60W LED power supply. 0- Brightness data based on 8500K, Pure White. Offiaal lM·79 report available upon request.O-00 maLED RGB 15 66i UL Recogmied.,7 · RGB Controller Specifications Input Voltage 9-15 DCV Weight 0.15 lbs Operating temp.-4 to 140°F Wet rating Dry and damp location Max. operating current per controller 5 Amp Max. serial connection 60W or 80 RGB Modules Max. connection of Sub·controllers 23 units 110 Emerson Place. Brooklyn, NY 11205 718-399-3333 43 Engineers Lane, Farmingdale, NY 11735 631·420-4400 0 °=LED 1171? 0 D e 9 E 2% k..1 n mr; " i: 3 '- / ,,3:;it fli- ap ,9, iv,ir.id. DuraLED module series for channel letters bring together quality illumination, reliability, and convenience in one complete package under one root Based on the latest and brightest LED technology in the market, Dura LED modules are energy efficient long lasting and easy to use, designed for use in all types of channel letter applications in indoors and outdoors applications Also packed with tons of enprgy-saving, safpty, and convenience features, there is no need to look further! DuraLED series is your complete LED solution for all your channel letter applications. n Practical, convenient and bright illumination solution for all types of channel letter applications .Im 0 Available in a variety of modules for fitting into 1341915 variety of channel letters f-th\ Ell YOJ'-I. Codib DuraLED RGB This module can produce many different colors when used with the RGB controller. Easy to use, just push a button to select any of the seven programmed color changing modes or select all modes to display in sequence. Can also be set to any color with the stop mode. 4#j *4,i O DuraLED Short is available in pure white red, green & blue modules, DuraLED Medium is available in pure white 13 Reliable & long lasting illumination m Bright 3-chip LEI)5 with strictest RANK control ¤ Double-sided PCB printing for additional thermal management O Slim & light-weight design n IP68 fully waterproof design for wet & damp location applicabons ¤ 4 Year Limited Exchange Warranty RGB Controller 0 8 different color-changing simulation effects 5 Cari be used as either Main controller or Sub-controller - max 80 modules for each controller ¤ Speed adjustable for the simulation O Comnact size Color Modes Model IR Ir.FFIFRFFHHF:FFIM O Simple installation & easy operation l'Al 1-1 1 1 1 1 -4- 1 -+-1 Available Modules: r RDuraLED Short Screw mount hole LEI) indicator -Bimr,r, In,lin,on tor current color MODE H-tz¤*e=Ot--- . --=dUL.* 1011- } -- 7-1/7 - -7-1/20 --2 RPure White Green t '9 4- -J 2 -55*NM UdL .-W L (7,4 -J,--1 L---Il-liltlel'.21/--- -CI.•Uh;411=2 r Red Blue..- DuraLED Medium IEER,Pozte.Clii K'L 9 M wide - 6 ode 7 Seque,•ce Asplay Spoid ial ' LED 440#tor -(10 i,ght : Paste Mod, A Stop Mo •10, ourrent MODE --Screw mount hole (lb lei:): Slower M(0 to 9) Sl K ort, S *wint rAM 2-7/8- r Pure White T ' 2/'-3 1 1 4 17'-10 80 sq ft9'-41/4" 7,blanet 7.675 11 LIC 42" p5'-5 1/40 J' fitness'L 63.5 sq ft38 sq ft 4 18'-81/2" GENERAL NOTES: - INTERNALLY ILLUMINATED "LED" CHANNEL LETTER WALL SIGN - UL 2161 COMPLIANT - SIGN AREA 182 SQ. FT. LettersLOgO OVER 7 'h LOGO LED CHANNEL MOUNT -1 ---- a LED CHANNEL FLUSH MOUNT NOTES: 1. 5"Deep.063 Aklmlnum Retums · Black 2. 1"Metal Mokmgs · Black 1 3/16" PIe*lass Faces· Wlite ,/ Vinyl Graphics 4 3/8" Threaded Rod · ntru Bolts 5. 3/8"Bolls 6. 292' Galvanized Wai Brackets 7. low Voltage Wklng from LED Strlp to Translormer & LED Powersouco 9. LED Ughtlng System,/HIgh Intenilly (Est 400 Candes per Meters Squars·GE Systems) 10. ,063 Allmlnum Backs· 11 3/16" Alumint,n Angled Aner Ramei< Weep H*s for Di,Inage . 9 L.LK -@ 3 3 1 ® NQIES: 1. F' Deep.063 Alumblum Returns · Purple to Match 3M Tms. 234118 Mulbe,ry ® 2.1" Vinyl Trim Cap·Black 1 3/16"Ple*ss Faces · White,/ Purple Vlmll to Natch 311 Trans. 230·118 Mi lberry 4.063 Aluminum Backs · 5. LED Ughtklg System w/High Intensity (Est 400 Candes per Metere Squars·GE Systems) 6. low Voltage Wiring from LED Sulp to Trlonner 7. LED Powersol•ce B. 1/4' Threaded Rod · TI,u Bolt 9, Weep Holes fo, Dralnage i > 3' i -t 9' - 4" Q 3' 1715 15' CO··f a. 3 0 1 A 200' parking lot frontage PLANET FITNESS 2725 N. BRISTOL STREET SANTAANA, CA 92706 '6 . LETTERS & LOGOS SIGN COMPANY INC. 22472 RIPPLING BROOK LAKE FOREST, CA 92630 949.583.9355 4;rv 1 U,¢50 k :<iblar. .ef t 1 -p==9*-- b' 72/AIL' #.#-'*6-11 , SIGN LOCATION 211*#1 -a t =22» ,EM.-4 112: i r - 'r,-0 WEST MEMORY LANE 0 e 0725- N M \ 0 (909-1,1 0 015% 3-1 9 \S0 A local disconnect for the monument sign(s)required or the dedicated c!rcuit breaker(s) musbe individually lockable in the off position. CEC 600-6000 cess to any power suppiy in attic or aboveediately from a ladder orUng sha\\ be immth a2*3 foot access door & passage with aWi-inch walkway. CEC 600-21 (d)(d)12 of Santa Ana Planning & Building AgencyC\W City of Santa Ana. CBC & CEC 2013t Minimum (4) screws per letter,maximum 24" on center, 2" penetration, #10 sheet metal screws, &(2) 44" drain holes per letter ELECTRICAL PLAN APPROVAL PERMIT TYPE:dec€*r pLBG 1 MECH *ADINGThis set of plans and speclfications must be lapt on | the job at all times and it Is unlawful to make any| changes or alterallons on same wIthout writtm pey- [1 mission from the Department of Building Safety,City Of Santa Ana. The approval 01 this plan and specifications SHALL, NOT bo beld to permit nor be an approval of theviola©3*Zr any provisions of ANY City Ordinanoeor State Law. .1 Approved 0*»83-U LIll_19' dITY OF SANTAANA DEPARTMENT OF BUILDING SAFETY ' %- PERMIT#10 I grarl,€ / OCC. GROUP 2201 A855 17 6 CONSTR. TYPE CODE EDITION 20 6 FLOOD ZONE X FLOOD ZONE CERTIF. REQ'D YES *O MICROFILM YES NC- RADIANT BARRIER @ ROOF YES <1 RESIDENTIAL DEV. FEE YES NO - j SCHOOL DISTRICT YES NO L- i....- :622£,6-49.12:64>· ... .,-*·Nza;Ase=.Mu,yp