Loading...
HomeMy WebLinkAbout1901 E Dyer Rd Unit#A - REV 1 - Plan? A3.1 1 6’ − 2 1 / 4 " 55 SF UNISEX RESTROOM 101 125 SF BREAK ROOM 102 WAITING AREA 2’ − 7"4’ − 0"2’ − 7" 9’ − 6 1/2" 9’ − 6 3/4" 5’ − 8 5/8" 4’ − 0" 2’ − 7" 1 2 2 2 2 3 1050 SF HAIR SALON 100 1 4 1 4 4 A3.1 27 7 7 8 9 10 11 12 CLR. 18"13 14 15 ’ − 0 " 9" 13 ’ − 1 " 9" 5’ − 0" 3’ − 0 " 11 ’ − 8 " W/D REF. CL R 3’ − 0 " 0 ROOM NAME 101 ROOM NAME & NUMBER. KEYNOTE CALLOUT − REF THIS SHEET DOOR − REF DOOR SCHEDULE SHEET A10.1 WALL TYPE − REF SHEET AD7.3 EXISTING WALL TO REMAIN NEW STUD WALL 2A FIRE EXTINGUISHER, SURFACE MOUNTED WITH WALL BRACKET. 48" TO TOP OF EXTINGUISHER ? 0 EXISTING RETAIL STORE EXISTING STORAGE 4 4 4 44 4 5 5 5 6 6 6 PE R S C H E D U L E 2" 2" SCHEDULE PER 2" I INTERIOR AS NOTED THIS DOCUMENT, THE IDEAS AND DESIGNS INCORPORATED HERE IN, ASAN INSTRUMENT OF PROFESSIONALSERVICE, IS THE PROPERTY OF MNDESIGNS CO. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF MND. THIS DOCUMENT IS NOT TO BE REPRODUCED AND/OR MODIFIED IN ANY WAY, NOR SHALL ANY REPRODUCTION OF THIS DOCUMENT BE MODIFIED WITHOUT THE PRIOR WRITTEN CONSENT OF MND. THIS DOCUMENT HAS BEEN PREPARED TO DESCRIBE PROPOSED NEW WORK AND DOES NOT NECESSARILY REPRESENT AS-BUILT OR EXISTING CONDITIONS. MND DOES NOT WARRANT, IN ANY WAY, THE ACCURACY OF THIS INFORMATION AND SHALL NOT BE RESPONSIBLE FOR ANY DISCREPANCY BETWEEN THIS DOCUMENT AND THE EXISTING CONDITIONS. DATE JOB NO.: SCALE: DATE: CHECKED BY: DRAWN BY: SHEET: ISSUE / REVISION STAMP: AS NOTED A PER P.C.C.03.21.2025 ISSUED FOR P.C. TITLE: B REVISION 07.30.2025 AZIZ KERALLS PROJECT MA MA 24100 OVERALL FLOOR PLAN A1.1 1901 E. DYER RD, UNIT A, SANTA ANA, CA 92705 AZ HAIR LOUNGE CLIENT 1901 E. DYER RD, UNIT A, SANTA ANA, CA 92705 01/28/2025 SCALE 1/4" = 1’−0"1PROPOSED FLOOR PLAN KEYNOTES 1 SHAMPOO WASH STATION 2 STYLING STATION 3 FRONT DESK RECEPTION 4 EXISTING COLUMN TO REMAIN 5 EXISTING DOOR TO REMAIN 6 EXISTING STOREFRONT TO REMIAN 7 DISPLAY SHELVES 8 UNISEX WALL SIGN 9 UNISEX DOOR SIGN 10 EMPLOYEES ONLY SIGN 11 NEW ELECTRICAL SUB−PANEL, REFER TO ELECTRICAL DWGS 12 REFRIGERATOR BIBB 13 WHEEL CHAIR SPACE 14 36" ACCESSIBLE ROUTE PLAN LEGEND FLOOR PLAN NOTES 1. ALL COUNTER HEIGHTS TO BE 34 INCHES IN HEIGHT. 2. ALL EQUIPMENT LOCATED ON COUNTERS, FOOD TRAYS, OR OTHER DISPENSERS INTENDED FOR USE BY PATRONS, SHALL BE LOCATED AND DESIGNED TO BE ACCESSIBLE IN ACCORDANCE WITH THE PROVISIONS OF CBC CH.11B. 3. INSTALL TILE PER MANUFACTURERS RECOMMENDATIONS. 4. TILE TO BE SET ON DIMENSIONALLY STABLE CONCRETE SUBFLOOR TO CONFORM TO ANSI A108.5 WITH ACRYLIC MODIFIED DRY SET MORTAR. ALL DRY SET MORTAR IS TO BE MIXED WITH ACRYLIC ADMIX IN LIEU OF WATER. 5. FLOOR TILE GROUTING IS TO CONFORM WITH ANSI A108.10 FOR GROUTING OF FLOOR TILE WITH ACRYLIC MODIFIED PORTLAND CEMENT GROUT. ALL GROUT IS TO BE MIXED WITH LIQUID WHICH CONSISTS OF ONE PART CLEAN WATER AND ONE PART ACRYLIC MORTAR ADMIX AS RECOMMENDED BY MANUFACTURER. 6. CLEAN TILE SURFACES AS THOROUGHLY AS POSSIBLE ON COMPLETION OF GROUTING AND REMOVE ALL GROUT HAZE. ACID BASED CLEANERS SPECIFICALLY PROHIBITED. RINSE TILE WORK THOROUGHLY WITH CLEAN WATER BEFORE AND AFTER USING AQUA MIX HEAVY DUTY TILE & GROUT CLEANER. POLISH W/ SOFT CLOTH. 7. SEAL GROUT WITH CUSTOM BUILDING PRODUCTS PENETRATING SEALER, APPLY PER MANUFACTURERS RECOMMENDATIONS. 8. ALL EXTERIOR WINDOWS ARE FIXED. 9. ALL WOOD IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED, MOISTURE RESISTANT WOOD. 10. ALL THE CABINETS UNDER THE BEVERAGE COUNTERS ARE EQUIPPED WITH LOCKING MECHANISMS. 11. EXTERIOR WALL DIMS ARE TO FACE OF CONCRETE FOUNDATION, OR CMU. U.O.N., FLOOR SINK DIMS ARE FROM FACE OF CONCRETE FOUNDATION U.O.N., INTERIOR WALL DIMS ARE TO FACE OF STUD U.O.N. ALL MIN. AND CLEAR DIMENSIONS ARE TO AND FROM FACE OF FINISH. DIMENSIONAL TOLERANCE FOR FORMWORK AND FINISHED CONCRETE INSTALLATION SHALL BE 1/4" IN 10’−0" FOR PLAN DIMENSIONS AND ELEVATIONS. 12. ALL SEALANT TO BE PAINTABLE. SEAL PERIMETER OF ALL WALL OPENINGS AND JOINTS WHERE MOVEMENT OF SURFACES WILL ADMIT AIR OR WATER INTO BUILDING. SEAL ALL CONDUIT PENETRATIONS TO BUILDING. 13. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE AND INSTALL ALL WOOD BLOCKING, FURRING STRIPS, OR GROUNDS DETAILED OR REQUIRED TO PROVIDE ANCHORAGE FOR ALL FINISHES, ACCESSORIES, FIXTURES, ETC. AS REQUIRED TO COMPLETE ALL WORK. ALL BLOCKING AND OR/BACKING SHALL BE SECURELY BOLTED OR OTHERWISE ANCHORED IN PLACE. 14. FIRE EXTINGUISHER: #10 CLASS ABC WITH UL RATING 4A−60BC. SURFACE MOUNTED ON WALL. 15. GENERAL CONTRACTOR SHALL VERIFY ALL BUILDING DIMENSIONS, AND SITE GRADES PRIOR TO START OF WORK. NNNN DE SI G NS ME A NA AGAI BY 562.412.0662 mea na @mndesi gns c o.c o m www.mndesi gns c o.c o m MNDesi gns DEMOLITION NOTES 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED PERMITS FOR DEMOLITION WORK. 2. THE CONTRACTOR SHALL VISIT AND CAREFULLY EXAMINE THE SITE, AND SHALL FULLY INFORM THEMSELVES AS TO ALL THE EXISTING CONDITIONS AND LIMITATIONS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTING ALL REQUIRED PEDESTRIAN PROTECTION, INCLUDING FENCES AND CANOPY; FOR CAPPING EXISTING SEWER LINES, ELECTRICAL CONDUITS, ETC. AND SHALL HAVE THE ABOVE ITEMS INSPECTED PRIOR TO STARTING ANY DEMOLITION. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBEYING ALL STANDARD OSHA SAFETY RULES AS SET FORTH IN THE OSHA (STATE OF CALIFORNIA) CONSTRUCTION SAFETY ORDERS. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTING ALL TEMPORARY SHORING BRACING, ETC., FOR EXISTING CONSTRUCTION TO REMAIN. DESIGN OF ALL TEMPORARY SUPPORTS SHALL CONSIDER ALL DEAD LOADS, LIVE LOADS, IMPACT LOADS, ETC., PER C.B.C. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE ORDER OF WORK TO BE PERFORMED FOR SHORING, DEMOLITION, AND NEW CONSTRUCTION FOR THE ENTIRE PROJECT. THE CONTRACTOR SHALL COORDINATE AND BE RESPONSIBLE FOR THE DISCONNECTION AND CAPPING OF ALL AFFECTED UTILITY SERVICES. ALL DISCONNECTIONS SHALL BE DONE IN ACCORDANCE WITH THE REGULATIONS OF THE UTILITY CONCERNED. CAP ALL UTILITIES BELOW GRADE. 7. THE CONTRACTOR SHALL COORDINATE THE WORK TO MINIMIZE THE INTERRUPTION OF UTILITY SERVICES, PARTICULARLY WATER, GAS, ELECTRIC, SEWER AND TELEPHONE SERVICES. WHEN POSSIBLE, INTERRUPTIONS TO SERVICES SHALL BE MADE DURING NON− OPERATING HOURS. SHOULD IT BE NECESSARY TO SHUT DOWN SERVICES DURING OPERATING HOURS, THE CONTRACTOR IS REQUIRED TO GIVE THE OWNER’S REPRESENTATIVE 24 HOURS WRITTEN NOTICE, AND BE LIMITED TO 30 MINUTE TIME INTERVALS, UNLESS OTHER ARRANGEMENTS ARE MUTUALLY AGREED UPON IN ADVANCE. 8. PROVIDE ADEQUATE PROTECTION TO EXISTING FACILITIES, AND AREAS NOT REQUIRED TO BE ALTERED. EXECUTE THE WORK IN SUCH A MANNER SO AS TO AVOID INTERFERENCE WITH THE USE OF, OR PASSAGE TO AND FROM ADJOINING BUILDINGS AND FACILITIES. 9. PERFORM ALL DEMOLITION AND REMOVAL OF WORK INDICATED ON DRAWINGS. SAWCUTS ARE REQUIRED AT THE BOUNDARIES OF CONCRETE, ASPHALT, AND MASONRY BLOCK WORK, TO BE REMOVED. 10. EXPLOSIVE, BLASTING, BURNING OF MATERIALS AND DEBRIS WILL NOT BE PERMITTED ON THE SITE. 11. ITEMS NOT DESIGNATED FOR RETENTION BY THE OWNER BECOME THE PROPERTY OF THE CONTRACTOR, WHO SHALL REMOVE SAME FROM THE SITE. VERIFY 48 HOURS PRIOR TO COMMENCING DEMOLITION WHETHER THERE ARE ANY ITEMS DESIGNATED TO BE RETAINED BY THE OWNER. REMOVE AND DELIVER ANY OWNER CLAIMED ITEMS TO THE SITE STORAGE AREA DESIGNATED BY THE OWNER. 12. CLEAN−UP; DURING THE DEMOLITION WORK, CONTRACTOR SHALL REMOVE ALL DEMOLISHED PARTS, TRASH AND DIRT IN A MANNER WHICH WILL LIMIT THE SPREAD OF DIRT AND DUST TO THE OTHER AREAS OF THE SITE. DIRECT TRASH AND DUST SPREAD TO OTHER AREAS SHALL BE CLEANED AND REMOVED FROM THE SITE BY THE CONTRACTOR. UPON COMPLETION OF WORK HEREIN SPECIFIED, ALL AFFECTED AREAS WILL BE LEFT THOROUGHLY CLEAN AND IN A SAFE CONDITION, FREE FROM MATERIALS OR EQUIPMENT EXCEPT SALVAGED MATERIALS TO BE RETAINED BY THE OWNER. 13. HAZARDOUS MATERIALS: UNLESS OTHERWISE PROVIDED, THE ENGINEER AND HIS CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO ASBESTOS, ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES. SCALE 1/4" = 1’−0"2EXISTING FLOOR PLAN NNNN FINISH SCHEDULE ROOM #ROOM NAME FLOOR WALL BASE WALL PAINT WALL COVER CLG CLG HEIGHT REMARKSN E S W N E S W E N S W 100 HAIR SALON F−2 B−1 B−1 B−1 B−1 P−1 P−1 P−1 P−1 C−2 EXPOSED CEILING TO BE PAINTED BLACK 101 UNISEX RESTROOM F−1 B−1 B−1 B−1 B−1 WC−1 WC−1 WC−1 WC−1 C−1 9’ − 0" 102 BREAK ROOM F−2 B−1 B−1 B−1 B−1 P−1 P−1 P−1 P−1 WC−2 WC−2 EXISTING 9’ − 0"CEILING TO BE PAINTED WHITE DOOR SCHEDULE DOOR # TYPE SIZE MATERIAL REMARKSWIDTH HEIGHT DOOR FRAME 1 I 3’ − 0" 7’ − 0" D1 F1 DOOR GENERAL NOTES 1. ALL SWINGING PANEL DOORS ARE ACCESSIBLE 2. ALL ACCESS CONTROLLED DOORS SHALL BE "FAIL−OPEN" WHEN FIRE ALARM IS ACTIVATED OR DURING LOSS OF POWER 3. THE ACTUATING PORTION OF THE RELEASING DEVICE SHALL EXTEND AT LEAST ONE−HALF OF THE DOOR LEAF WIDTH. 4. THE MAXIUMUM UNLATCHING FORCE DOES NOT EXCEED 15−POUNDS 5. WHERE KEY−LOCKING DEVICES ARE USED, POST A SIGN ON OR ADJACENT TO REQUIRED MAIN EXIT DOOR WITH 1−IN. LETTERING STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" 6. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. DOOR HARDWARE NOTES 1. EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE, OR EFFORT. DOOR HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERATING DEVICES SHALL BE INSTALLED 34 TO 48 IN. ABOVE THE FINISHED FLOOR. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. (1010.1.9) 2. FOR ALL DOORS, VERIFY LOCKING FUNCTIONS AND MASTER KEYING WITH OWNER PRIOR TO INSTALLATION 3. ALL DOORS SHALL HAVE LEVERED HANDLES UNLESS NOTED OTHERWISE 4. OPENING HARDWARE IS TO BE INSTALLED BETWEEN 34" AND 48" ABOVE FINISH FLOOR 5. ALL SWINGING PANEL DOORS TO HAVE 10" KICK PLATE (AS NOTED) OR SMOOTH SURFACE OF EQUAL SPACE PER CBC 1133B.2.6 6. ALL DOOR THRESHOLD TO BE MAXIMUM OF 1/2" FOR ADA ACCESIBILITY DOOR MATERIAL D1 HOLLOW METAL PANEL FRAME MATERIAL F1 HOLLOW METAL FRAME DOOR KEYNOTES 10. ALL INTERIOR CONCRETE: SMOOTH STEEL TROWEL FINISH 11. FINISH MATERIALS SHALL COMPLY WITH CALGREEN SECTIONS 5.504.4.1 THROUGH 5.504.4.6 12. VERIFICATION OF COMPLIANCE WITH CALGREEN SHALL BE PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. 13. INTERIOR WALL AND CEILING FINISH MATERIALS APPLIED TO WALLS AND CEILINGS SHALL BE TESTED AS SPECIFIED IN SECTION 803. 14. NON−ABSORBENT INTERIOR FLOOR AND WALL FINISHES SHALL BE USED WITHIN AT LEAST 2 FEET AROUND AND PERPENDICULAR TO EXTEIOR ENTRIES AND/OR OPENINGS SUBJECT TO FOOT TRAFFIC 15. WALLS AND CEILINGS OF ALL ROOMS SHALL BE OF A DURABLE, SMOOTH, NONABSORBENT, AND EASILY CLEANABLE SURFACE EXCEPT FOR AREAS AS SPECIFIED IN 114271 (B). WHEN OTHERWISE INSTALLED, THEY SHALL BE MOUNTED OR ENCLOSED SO AS TO FACILITATE CLEANING. ATTACHMENTS TO WALLS AND CEILINGS, SUCH AS LIGHT FIXTURES, MECHANICAL ROOM VENTILATION SYSTEM COMPONENTS, VENT COVERS, WALL MOUNTED FANS, DECORATIVE ITEMS, AND OTHER ATTACHMENTS, SHALL BE EASILY CLEANABLE. SECTION #: 114143, 114271 1. CEILING CONTRACTOR TO SUBMIT SHOP DRAWINGS OF ALL WORK BEING PERFORMED 2. INSTALL OWENS CORNING FIBERGLAS BATT INSULATION ’FLAME SPREAD 25’ W−PSK INSULATION W/ EXTENDED FLANGES. COMPLIES W/ ASTM E−84, TYPE II, CLASS A "FLAME SPREAD" IS CLASS I. 3. ALL PAINT TO HAVE 1 PRIMER COAT AND 2 FINISH COATS 4. ALL CONSTRUCTION MATERIALS SHALL BE NON−COMBUSTIBLE EXCEPT THOSE ALLOWED IN IFC SECTION 807.1.2 AND IN ACCRDANCE WITH IBC SECTION 803.11 (I.E. CLASS A CEILING TILES AND INSULATIONS AND FIRE TREATED WOOD, IF USED) 5. ALL FINISHES AND COVERINGS SPECIFIED ARE BASIS OF DESIGN AND THE CONTRACTOR MAY SUBMIT FOR APPROVED EQUAL 6. PROVIDE MOISTURE RESISTANT GYPSUM BOARD IN ALL WET AREAS 7. DRYWALL FINISH TO BE CLASS 4 8. ALL SURFACES: EGG−SHELL FINISH PER SPECIFICATION 9. KITCHEN, JANITOR AND RESTROOM SURFACES: SEMI−GLOSS FINISH PER SPECIFICATION FINISH GENERAL NOTES B−1 700 SERIES, THERMOPLASTIC RUBBER ROPPE / 4" x 1/8" x 120’ COVE DARK GRAY OR TENANT TO SELECT WALL BASE WC−2 FRP MARLITE STANDARD FRP PEBBLED SURFACE/ WHITE UP TO 4’−0" ABOVE THE MOP SINK WC−1 WALL TILE DALTILE 4 X 12 DESERT GRAY / MATTE OR TENANT TO SELECT WALL COVER P−1 PAINT BENJAMIN MOORE − AURA WHITE / SEMI−GLOSS OR TENANT TO SELECT WALL PAINT F−2 SEALED CONCRETE EXISTING CONCRETE EXISTING CONCRETE OR TENANT TO SELECT F−1 PORCELAIN TILE DALTILE 2x2 SUEDE GRAY D208 / MATTE OR TENANT TO SELECT FLOORING PL−1 PLASTIC LAMINATE WILSONART / SOFT−CLOSE LINEN D427−60 OR TENANT TO SELECT SS−1 SOLID SURFACE CORIAN EVEREST OR TENANT TO SELECT CASEWORK C−2 OPEN STRUCTURE OPEN STRUCTURE BLACK OR TENANT TO SELECT C−1 WATER RESISTIVE GYPSUM BOARD USG ENSEMBLE ACOUSTICAL WHITE / SMOOTH SURFACE OR TENANT TO SELECT CEILING ITEM # ITEM NAME MANUF / PRODUCT COLOR / FINISH COMMENTS FINISH LEGEND B B REVISION Bldg# 101124765 APPROVALS PLNG - CSantanaBLDG - CSG Consultants EQ EQ EQ E Q HAIR SALON 100 UNISEX RESTROOM 101 BREAK ROOM 102 9’−0" 9’−0" 1 TYP. 2 1 3 33 TYP. E.S.GYPSUM BD CEILING ? CEILING HEIGHT A.F.F. KEYNOTE CALLOUT − SEE THIS SHEET ROOM NAME & NUMBER ROOM NAME 101 1 X 4 SURFACE MTD LIGHTING FIXTURE PER ELEC DWGS ILLUMINATED EXIT SIGN − REF ELEC DWGS 0 EXPOSED STRUCTUREE.S. MILL WORK CABINET OR COUNTER 3/8" R CERAMIC FLOOR TILE BASE TILE 1/4" THICK MAX. SETTING BED (TYP.) 3/16" GROUT (TYP.) SEALED CONCRETE 3/8" R CERAMIC TILE BASE 1/4" THINSET GROUT SETTING BED WALL FINISH OR FACE OF CABINET (WHERE OCCURS) 3/8" R CERAMIC FLOOR TILE BASE TILE 1/4" THICK MAX. SETTING BED (TYP.) 3/16" GROUT (TYP.) 3/4" CDX PLYWD., WRAP ENTIRE SHELF w/ 24 GA. STAINLESS STEEL OR EQUAL. WATER HEATER, SEE PLUMBING DRAWINGS GALV. SHEET METAL PAN PAINT SEISMIC STRAP BLOCKING T.F.S. CEILING PER PLAN 5/8" GYP. BD. OVER 2 X FRAMING @ 16" O.C. F.R.P. PANEL, T.O. MOP SINK TO UNDERSIDE OF WATER HEATER SHELF PER RCP 6’ − 0" BRACE SUPPORT PER GC INTERIORINTERIOR DOOR AND FRAME PER SCHEDULE HEADER & JAMB PER LIGHT GAUGE CONSTRUCTION WALL PER WALL TYPE ADA COMPLIANT THRESHOLD SET IN SEALANT PER SCHEDULE CONC FLOOR PER STRUCT FLOOR FINISH PER SCHEDULE HEAD/JAMB THRESHOLD NOTE: THRESHOLD OCCURS AT CHANGE OF FLOOR MATERIALS 5/8" GYP. BD. 2x6 CEILING JOISTS @ 16" O.C. 2x LEDGER HU24 1/2" x 3 1/2" LAG @ EACH STUD (16" O.C.) PER RCP FINISHED MATERIAL 1 1/4" ~ GRAB BAR PER NOTE: GRAB BAR TO SUPPORT 250 POUNDS MINIMUM. METAL STUD BACKING TO MATCH WALL THICKNESS METAL BACKING PLATE ATTACH W/ 3 3/8" R.H.M.S. AS SHOWN 1 1/2" 33 " T O 3 6 " FI N I S H F L O O R AS NOTED THIS DOCUMENT, THE IDEAS AND DESIGNS INCORPORATED HERE IN, ASAN INSTRUMENT OF PROFESSIONALSERVICE, IS THE PROPERTY OF MNDESIGNS CO. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF MND. THIS DOCUMENT IS NOT TO BE REPRODUCED AND/OR MODIFIED IN ANY WAY, NOR SHALL ANY REPRODUCTION OF THIS DOCUMENT BE MODIFIED WITHOUT THE PRIOR WRITTEN CONSENT OF MND. THIS DOCUMENT HAS BEEN PREPARED TO DESCRIBE PROPOSED NEW WORK AND DOES NOT NECESSARILY REPRESENT AS-BUILT OR EXISTING CONDITIONS. MND DOES NOT WARRANT, IN ANY WAY, THE ACCURACY OF THIS INFORMATION AND SHALL NOT BE RESPONSIBLE FOR ANY DISCREPANCY BETWEEN THIS DOCUMENT AND THE EXISTING CONDITIONS. DATE JOB NO.: SCALE: DATE: CHECKED BY: DRAWN BY: SHEET: ISSUE / REVISION STAMP: AS NOTED A PER P.C.C.03.21.2025 ISSUED FOR P.C. TITLE: B REVISION 07.30.2025 AZIZ KERALLS PROJECT MA MA 24100 REFLECTED CEILING PLAN & DETAILS A2.1 1901 E. DYER RD, UNIT A, SANTA ANA, CA 92705 AZ HAIR LOUNGE CLIENT 1901 E. DYER RD, UNIT A, SANTA ANA, CA 92705 01/28/2025 SCALE 1/4" = 1’−0"1REFLECTED CEILING PLAN KEYNOTES 1 NEW LIGHT, REFER TO ELECTRICAL DWGS 2 WATER HEATER ABOVE 3 EXISTING COLUMN TO REMAIN RCP LEGEND RCP NOTES 1. REF ELECTRICAL DWGS FOR ALL POWER, DATA & LIGHTING FIXTURE INFO 2. REF MECHANICAL DWGS FOR ALL DUCTS & VENTS LAYOUT 3. REF FINISH SCHEDULE FOR ADDITIONAL INFO DE SI G NS ME A NA AGAI BY 562.412.0662 mea na @mndesi gns c o.c o m www.mndesi gns c o.c o m MNDesi gns SCALE 3/4" = 1’−0"5BASE TILE DETAIL SCALE 3/4" = 1’−0"2WATER/HEATER DETAIL SCALE 3" = 1’−0"6INT DR HEAD/JAMB/THRESHOLD SCALE 1" = 1’−0"4CEILING TRANSITION SCALE 1 1/2" = 1’−0"3GRAB BAR SUPPORT NNNN B