rq R[C'D PHOTOVOLTAIC
CHECKLIST
IUI
CitY of Santa Ana
sol-01 cBC 2013
Solai Photovoltaic (PV) Checklist for Detached STNGLE FAMTLY RESIDENGES Only
lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 1 1" x 17" size. lf answerino NO to anv of the ouestions. Dlan check shall be required.
Project Address:1209 ELAINE DR, SANTA ANA, CA 92703
contractor company Name: SOUTHWEST SUN SOLAR, INC
contractorLicenseNumber: 1004667
4
6
7
YES NO
Ettr
z. Eltr
I Etr
g tstr
ro. BE
mtr
Ettr8tr
Etr
atr
Are the following applicable to the proposed proJect?
Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the Califomia Fire Code, and is this shown on the roof plan?
Will the PV system be installed on a roof having only one roollng layer with no
overlays?
Will the PV array be flush mounted to the existing roof so that the plane of lhe
modules (panels) are parallel to the plane of the roof?
Will the PV system weigh maximum 4 pounds per square feet or less?
Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
Will the PV system be installed with a space of 2" minimum to 10" maximum between
the underside of modules and the surface of the roof?
Will the PV system bs installed without using any ballast system or counter-weight
system?
Will lhe anchors be installed wilh a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
Will the minimum 5/16" lag screws be installed with a minimum ol2-112inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
Are ALL the structural pages of the plans WET stamped and signed by a Californja
licensed professional engineer? (including project speciflc site plan, PV layout,
anchorage spacing, anchorage detalls and manufaclurer's PV support information.)