Loading...
HomeMy WebLinkAbout1209 N Elaine Dr - Misc. Permit,--SANTA NAJ|il}ffi Planning & Building Agency Building Safety DiviBlon 20 Civic Center Plaza "'' "t*[f,oENrALr.mT P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-s8oo www.santa-ana.org rq R[C'D PHOTOVOLTAIC CHECKLIST IUI CitY of Santa Ana sol-01 cBC 2013 Solai Photovoltaic (PV) Checklist for Detached STNGLE FAMTLY RESIDENGES Only lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 1 1" x 17" size. lf answerino NO to anv of the ouestions. Dlan check shall be required. Project Address:1209 ELAINE DR, SANTA ANA, CA 92703 contractor company Name: SOUTHWEST SUN SOLAR, INC contractorLicenseNumber: 1004667 4 6 7 YES NO Ettr z. Eltr I Etr g tstr ro. BE mtr Ettr8tr Etr atr Are the following applicable to the proposed proJect? Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the Califomia Fire Code, and is this shown on the roof plan? Will the PV system be installed on a roof having only one roollng layer with no overlays? Will the PV array be flush mounted to the existing roof so that the plane of lhe modules (panels) are parallel to the plane of the roof? Will the PV system weigh maximum 4 pounds per square feet or less? Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? Will the PV system be installed with a space of 2" minimum to 10" maximum between the underside of modules and the surface of the roof? Will the PV system bs installed without using any ballast system or counter-weight system? Will lhe anchors be installed wilh a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? Will the minimum 5/16" lag screws be installed with a minimum ol2-112inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? Are ALL the structural pages of the plans WET stamped and signed by a Californja licensed professional engineer? (including project speciflc site plan, PV layout, anchorage spacing, anchorage detalls and manufaclurer's PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: print Name: MlMl NGO phone Number: 714 582 3909 Signature Date: Email Address Re\:al1712015 PERMIT@SOUTHWESTSUNSOLAR.COM