Loading...
HomeMy WebLinkAbout10181103_3118 S. LOWELL - PlanCITY OF SANTA ANA BUILDING PERMIT APPLICATION WORKSHEET PLEASE PRINT PROJECT ADDRESS: 3118 S Lowell Street USE OF BUILDING: RESIDENTIAL COMMERCIAL SUITE: INDUSTRIAL OTHER 3/2/05:forms/Bldg.App.Worksheet SAPIN #I o 1 -€) 1 .Ce MASTERID# NATURE OF WORK: NEW ADD ALTERIT.I.DEMO REROOF REPAIR SIGN MISC NEW/ADDITION/ALTERATION· 1ST FL.. . SF BASEMENT: YES/NO SF NO. OF STORIES: 2ND FL.. . SF PATIO/ENCL. PATIO:SF BLDG. HEIGHT: TOTAL OF OTHER FLS:SF RES. REMODEL: SF PROPOSED USE GARAGE/CARPORT: . SF ALTER/T.I.: SF JOB DESCRIPTION (non-residential projects see reverse side of this application) : 4 .15 k.w @60+ 'nY]Jr¥hfil36\Oten n pAW,W\,t; 17 m<C.¥-0-\YWEEk.AS, 1 dITS conritck, LOF>cow; 4 BUILDING OWNER'S NAME:PHONE NO:714-545-5280Eric Dalhes ADDRESS·CITY·STATE:CA ZIPr 927073118 S Lowell Street ·Santa Ana TENANT'S NAME (Comm/Ind):PHONE NO: CONTRACTOR'S NAME: Vivint Solar STATE CONTR. #: 973756 LICENSE CLASS:PHONE NO: C-46 657-600-8252 ADDRESS:CITY:STATE:ZIP' 1529 E MeFadden Ave Suite A Santa Ana CA 92705 WORKERS COMP. POLICY# WC 029342335 EXP. DATE: 11-1-2014 INSURANCE COMPANY: AIG Claims, Inc. SANTA ANA BUS. LIC. # ARCHITECT/ENGINEER:STATE LICENSE #:PHONE NO: ADDRESS:CITY:STATE:ZIP: CONTACT NAME: Amber Steinbeck PHONE Ne: 657-600-8252 / 714-815-5772 E-MAIL ADDRESS: amber.steinbeck@vivintsolar.com / OrangeCountySolar@vivint.com OFFICE USE ONLY:ACC OR SPC (CIRCLE ONE)HRS PER BLDG. FEE $ 49- OCC, GROUP:RECEIPT#:P/C FEE PD $ TYPE OF CONSTR:VALUATION: $71 , 150.03 SUBMITTAL DATE: H,-46 -44 FIRE SPKR: YES / NO A/C: YES / NO ,FLOOD ZONE.PROCESSED (-6 RES. DEV. FEE: YES/NO PRIOR DWELLING UNIT: YES / NO COMMENTS: PLANNING OK TO CHECK & DATE-BLDG. DEPT. APPROVAL & DATE PLNG CONDITIONS: PLEASE CHECK ALL THAT APPLY TO YOUR PROJECT JOB DESCRIPTION CHECKLIST: El Additional square footage 0 Awnings E Canopy £ Card readers Il Ceiling work U Change of occupancy (use) U Disabled accessible (H/C) restrooms E Dust collector U Elevator shaft U Exteriof doors or windows Equipment pads U Interior demo E Kitchen equipment L U Partition walls El Rated corridors U Rated shafts C] Roof mounted equipment E Security bars U Screening for equipment O Skylights E Stairs U Storefront/facade improvements U Storage racks or shelving over 5'-9" U Walk-in coolers ITEMS REQUIRING SEPARATE BUILDING PERMIT APPLICATIONS: Block wall Complete demo Fence Fire signaling system Fire sprinklers Flagpole Lawn sprinkler system Light Stahdards Parking lot paving Parking lot striping ¥ Pedestrian protection Pool/Spa Signs Spray booth Temporary power pole Trash enclosure GENERAL NOTES: INDEX OF DRAWINGS SHEET PV 1.0 - SITE PLAN SHEET PV 2.0 - ROOF PLAN SHEET PV 3.0 - MOUNT DETAILS -- ARCHITECTURAL STRUCTURALACCEPTED FOR CONSTRGCTION SEPARATE PERMNS ARE REGLURED FOR' ELECTRICAL, PLUMBING & MECHANICAL PLANE; rhts 801 of plans and specifications must b 3 kept on the jot.at 84 times and it is unlawful to make any changes or11*,erations oR same without written, permission from ;thE -JUNCTION BOX ATTACHED TO ARRAY USING ZEP ZS-GAB TO KEEP JUNCTION BOX OFF ROOF, Covourr {ris'MILOD 04*20- dPfl/6 0€ MUSE City of Santa Ana. The acceptance of this plan and specifications SHALL N01 be held to permit nor bean approval of thi violation of ani provisions of ANY City Ordinance or State L aw. uun - 1 1-1 SAL ;mir- Date Issued-t-R--3*1 UTILITY METER LOCATION APPROWEA ELECTRICAL PANEGING i'VISiON - -tj 90614 ···4Mrlof G.P Zmt PLANNER /3 DATE t l TRANSFERRED BY DATE PLANNING INSPECTION REQUIRED: ROUGH FINAL _NONE / NAME (714) - RETAIN PLANS FOR FUTURE REVISIONS. SUBJECT TO ITEMS CHECKED AND CONDITIONS BELOW: O INTERIOR TI ONLY O NO EXTER!(DR ALTERATIONS/MODIFICATIONS O ALL VATERIALS TO ?CATCH EXISTING O SCRec,JIN·.0 8,(t=U' i=,lco O ..3_·bi.'i;T LANDSCAPE PLANS 1 STORE@il*t!©INRE PERMITTYPE:«EDLECT PLBG - MECH GRADING PERMIT# \0\-%\. 103 ... OCC. GROUP R 3- / CONSTR. TYPE VA CODE EDITION 8 c__10 13/ FLOOD ZONF l FLOOD ZONE CERTIF. REQ'pYES O 'A /NO ] NO_ NO !1llill, \/ MiCROFILM YES ' " RADiANT BARRIER 94ooF YES I RESIDENTIAL DEy'EE YES .. fkr:Hont. D:s.TAT YES _«-14////lill/Uillifililillill/li//in' '4/n, 04-7///illi//////1 l li///ill/ill ll/lli, - aillillillillillillillillilli7/lillilll/f/Illflifill/Jili,---:f'/lummuum - 3' OFFSET FOR · ROOF ACCESS PV SYSTEM SIZE: 4.25 kW DC / / ' / 9% 100 .' li / / / / 17) Yingli Energy YL250P-29b MODULES WITH, -» (17) Enphase M215-60-2LL-S2x-ZC MICRO-INVERTERS. (ONE ON THE BACK O;F EACH MODULE) 1. ALL WORK SHALL CONFORM TO 2013 CBC, 2013 CRC, 2013 CPC, 2013 CMC, 2013 CEC, 2013 CALIFORNIA ENERGY CODE, 2013 CA lf') COGREEN CODE AND CITY ORDINANCES w 3;INSPECTION NOTES. - , . 1. THE FIRST REQUIRED INSPECTION SHALL *BE FOR IHE MODULE-RACK SUPPORT BASES.CD co- MODULE RACK SUPPORT BASES SHALL BE.....---e-·--- INSTALLED PER MANUFACTURE' INSTALLATION INSTRUCUONS.AR¢ @TE@§6RAL 2. LADDERS SHALL BE PROVIDED AND' SECURED TO THE STRUTURE FOR INSPECTIOPURPOSES.23 25 3. CONTRACTOR TO BE PRESENT FOR liIRSTAND FINAL INSPECTIONS.1 *U'I ¤2.3 pt nFS|NG4. ALL INVERTERS, MOTOR GENERATO.S2©T I©(131.tf'f C·<12 PHOTOVOLTAIC MODULES, PHOTOVOLTAIC ERs 00 ipocifica PANELS, AC PHOTOVOLTA]C MODULES this set 6 SOURCE-CIRCUITS COMBINERS, AN[M @ , bl same wittioutCHARGE CONTROLLERS INTENDED FOR usd**91.-'Ana IN' A PHOTOVOLTAIC POWER SYSTEM SHALC.\ty 01 3% 1114 -- IDENTIFIED AND LISTED FOR THE; APPLICATION PER 690.4(D).t he acof ptance ct u lis plan < 5. THE DISCHARGE OFPOLLUTANTS TO ANYle held .0 permit nc r be an STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM BYPRODUCTS,nrovisious of AN" City Ordin SOIL PARTICULATE, CONSTRUCTION WASTE MATERIAL OR WASTEWATER GENERATED ON -....-*-*--*CONSTRUCTION SITE OR BY CONSTRUCTION 1(*#Py 10 By ACTIVITIES SHALL BE PLACED, CONVEYED OR CITY Or DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM.1 1» A 04 8/ M C) M 2 0 -U) m GO OF 1" ElVIT CONDUIT (Ua) FROM JUNCTION BOX TO ELEC PANEL C 9 ' g M X m 20/ co % E.+J 0 - 9 2C co 62 (D i1-LLI.0 W 25:53fA > z .. 05 05' u : >- L.U. LLI Z [n ECE I 4> fe of Cah.,/4 --1' d W z0 ..4....····....1,0- b #=a < < 0 * -600 APR 1 5 2014 2 -SHEET CD NAME:09:4, 0 -0..b 6/. S2 %> %: 97375..° e yCity of Santa Ana 4/ 0'Conics,0 O LUZ"411,111"%„0 --1 1- < .-Ii'. 00 SHEET( NUMBER: PV SYSTEM SEE PLAN 7 O-- SCALE: 1/8" = 1'-0" C A AO & epa ' ci-UL.UUJI L 0 41 a 4/t LL INDEX OF DRAWINGS SHEET PV 1.0 - SITE PLAN SHEET PV 2.0 - ROOF PLAN SHEET PV 3.0 - MOUNT DETAILS ARCHNECTURAL STRUCTURALACCEPTED FOR CON:STR 3CTiON SEPARATE PERMQTS ARE REQi MED FOR ELE©miCAL, PLUMBING & MECHANICAL PLANE, rhis 801 of plans and specifications must b 3 kept on the jot3.2 at! times and it is unlawful to make any changes 01atterations on same without written, pernlission from theCity of Santa Ana. . The acceptance of this plan and specifications SHALL N01be haiti to permit nor be an approval of the violation of aniprovisions of ANY Citv Orriinmnce or State L aw. i ' Date -S Accepted B 3 -1-/9 A----et,YOF S;ir-- I L[)ate Issued.4-.u_3-Ld-j- UTILITY METER LOCATIOK ALPRO¥*D ELECTRICAL PANEP1*ANNING51VISION \- j PV INTERCONNECTION POINT, - , / -%k?A'*'1@ASE?;INECT SWITCH L.'-i Zone rit.IVIN,=n TRANSFERRED BY DATE PLANNING INSPECTION REQUIRED: ROUGH FINAL NONE / NAME (714) - RETAIN PLANS FOR FUTURE REVISIONS. SUBJECT TO ITEMS CHECKED AND CONDITIONS BELOW: O INTERIOR TI ONLY O NO EXTERIC-P,#t rERATIONS/MODIFICATIONS O ALI vaTER!*ch ; 2 CATCH EXISTING O Or.... RE-ND•M. S.LU -RED O .1-juid -AbboLAPE PLANS 1 STOR'(5@,4-BUGALIRE &1'0-A AG i /1. YES NO 62- -YES 1 -NO W YES NO_4 YES \ NO/ lilli!11111Ill!11111 li 11*91 PERMIT TYPE:-BLD-LECT PLBG MECH GRADING -JUNCTION BOX ATTACHED TO ARRAY USING ZEP ZS-GAB TOPERMIT# \o \ ls\L Upy:t KEEP JUNCTION BOX OFF ROOF, OCC. GROUP R.3 -/ CONSTR.TYPE VO 1 CODE EDITION (O -f C--A.D f.g,/ _ FLOOD ZONE --Cououff i,5-i,u. UL#Ne,0 676 · oF th;AcE FLOOD ZONE GERTIE. REQ'YES -70 j - - MICROFILM ..RADIANT BARRIER 940 " .' RESIDENTIAL DEy/FEE .il :43-1001 Dis-VAT 4-kililly///#ll/illillii'//ili 1 1- 3' OFFSET FOR ' 0>. ROOF ACCESS PV SYSTEM SIZE: 4.25 kW DC 1 ' / -/ /' ME ©BI APR 152 /City of San / 17) Yingli Energy YL250P-29b MODULES WITH -4 (17) Enphase M215-60-2LL-S2x-ZC MICRO-INVERTERS. (ONE ON THE BACK OF EACH MODULE) GENERAL NOTES: 1. ALL WORK SHALL CONFORM TO 2013 CBC, 2013 CRC, 2013 CPC, 2013 CMC. 2013 CEC: 2013 CALIFORNIA ENERGY CODE. 2013 CA. M GREEN CODE AND CITY ORDINANCES CD INSPECTION NOTES: * 5 1 THE FIRST REQUIRED INSPECTION SHALL BE FOR THE MODULE-RACK SUPPORT BASES. a) MODULE RACK SUPPORT BASESSHALL BE--e-'-/.man INSTALLED PER MANUFACTURE'!7=---ARC *fTE=wimogg:.INSTALLATION INSTRUCTIONS.05/J2. LADDERS SHALL BE PROVIDED AN[1 .P- 2,,NO-1 n.!EbSECURED TO THE STRUTURE FOR INSRECTIOe 805 RE@*'4&# (D 30&PURPOSES. -,J '6 D3 CONTRACTOR TO BE PRESENT FOR FIRST *rg '913- letrrs B AND FINAL INSPECTIONS.'8 SEPP 0, „_,f% g j,:Jrdorde4. ALL INVERTERS, MOTOR GENERATORSNg:£©3% C(1269.<e ·PHOTOVOLTAIC MODULES. PHOTOVOLTAI,0 01 1*PS 100 cificaPANELS AC PHOTOVOLTAIC MODULES 9 114 3 unlawfS6UIRCE-CIRCUITS COMBINERS, ill[9£41* il ?71_-n'Q without CHARGE CONTROLLERS INTENDED FOR US&109*OR -Ill SU IN A PHOTOVOLTAIC POWER SYSTEM SHAL[Mw 01 St nla A a IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(D). 5. THE DISCHARGE OF POLLUTANTS TO ANYNO SOLID WASTE, PETROLEUM BYPRODUCTovis ol AN" Cty OnSTORM DRAINAGE SYSTEM IS PROHIBITED. SOIL PARTICULATE, CONSTRUCTION WASTE MATERIAL OR WASTEWATER GENERATED ONCONSTRUCTION SITE OR BY CONSTRUCTION 1**Py y ACTIVITIES SHALL BE PLACED, CONVEYED OR CITY OF DISCHARGED INTO THE STREET: GUTTER OR STORM DRAIN SYSTEM. 114101* 1 0.- 04 .- m 0 5,3 05' OF 1" EMT CONDUIT (OCD FROM JUNCTION BOX TO ELEC PANEL C C Wh m(0 545*O-95 C »EEL -.I Zmh CU s=23 - D c _1 of €X: W > „- ME: tEEl a Z40 4/09h J < 6£00 - SHEETdE Ii-I-CD NAME: Ana ',PO' ConUB,0"O LUg-1 +CL - - ..1 co SHEETC¤ NUMBER: PV SYSTEM SITE PLAN - r-0 - SCALE: 1/8" = 1'-0" G.P n, Al,Aten Irs Pl DATE (. 1 7 'eof CIt,1 0/44> 2.......0:444 ,%, .10 & c...,#, 11"'1114, A -24 Roof Section 2 Roof Az.rpm: 150 Roof Tilt 23 -1 -TIE INTO METER# 222013570883 Roof Section 1 Ro:]f Azimuth: 150 Roof Tilt 23 CD 0 . 0, g O 02 r--4@t: 00) 4>01 - 140,1.2.O. 0 58 co<O S &06*CHAMIC Cl 41 te natie anywritteu permiss; ind spacification mc jor State La, llllllllIIlllllllllUIllI1Ill' illl/lillillillillK,furfA ANA UT1- / 1 / 1 / l t-TN+LL.V / 1 i CHIMENY |-3L--1 'llillillillillillill1111111111111Illi .lillijillilliJUN-N-Ill-Flill 1 B 0 .. 'iTMYTl-iii 7///// / / / i ///////0. -Cal) --' 'l+U-lJ llillijill, -g 91:-1 I Ill FITI.- tlld i i e tz. -OMP. SHINGLE d f i1 7 51 1 0 5 65 0efEP%59 44 1- 1- 3 -3 1 0, swom'•V.17 MODULES ROOF VENT(S) 0 n : cody U) Z PLUMBING VENT(S-,Peed Co@> 'P SHEET !NUMBER: PV SYSTEM ROOF PLAN MAXIMUM OUTPUT SHALL BE RATED FOR ARRAY ORIENTED TO THE EAST SCALE: 1/4" = 1'-0" e- 9661>6 L COMP MOUNT (ZS-CMA) WATERPROOFING SEALANT AS NEEDED. WITH FLASHING PV ARRAY TYP. ELEVATION i 5/16"0-18xl" STAINLESS LEVELING FOOT (ZS-LFB) --STEEL M.B.: TORQUE = 16+1 ft-·lbs. NOT TO SCALE r« r I 1»41 i WASHER PACKAGED 5- WITH COMP MOUNT 1 ) MOUNTING X m nk DETAILty PV MODULE, UP. MOUNT TO RAFTERS OF COMP SHINGLE ROOF, PARALLEL WITH PLANE OF ROOF NJ 0-5/16"0* 4 112"MINIMUM- --1 ;SHALL NO T STAINLESS.STEEL LAG.SCREW daug,1 of c. 'y TORQUE = 13+2 ft-lbs. i lie===I r --42=29 LEVELING FOOT ON COMP MOUNT 2% NOT TO SCALE Bl PERMITTED LEVELING: /.--FOOT SPACING -LEVELINA FOOT (ZS-LFB) ,_„ FRAMING BELOW SHOWNDASHED FOR CLARITY CANTILEVER = L/3 OR LESS ZEP COMPATIBLE HYBRID (2' MAX CANTILEVER). 1 1 PV'MODULE INTERLOCK ,#,%"111114,/,4,MA SPACING 48'' ¤ | | /·''f < I I I I 1- I 0 01 Ca/if 4/ - 9 1 - PHDTOVOLTAIC MODULE 1 1 1 i 1 1 1 1 PETE M C® 41 '4 111 1 CM 1 1 111 1 1! 1 * i Cody»Ze=¥=, 1 1 1 1 111 1 1 1 11 1 1- 1- - \- INTERLOCK (ZS-ILED HYBRID INTERLOCk 11 1 LEVELING FOOT (ZS-LFB)R0OF FRAMING 11 1 11 1 1 4. 1 ,ljl!l /,4,'sed Conf',00' LEVELINGFOOT (ZS-LFB) SHEET NAME: INTERLOCK (ZS-ILB) -PERMITTED LEVELING 20PV SYSTEM MOUNT DETAIL FOOT SPACING (6· MAX SPAN)SHEET SCALE: 1/2" = 1'-0" NUMBER: MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 3 Inverter Ratings (Guide Section 41 MODULE DETAIL |Inverter Make/Model Enphase M215-60-2LL-S2x-ZC Max DC Volt: Rating 45 Volts Yingli Energy YL250P-29b 1 Max Power @ 40°C 2,M Watts SOLAR MODULE |Nominal AC Voltage 240 Volts\\\1 Max AC Current 0.9 Amps Max OCPD Rating 20 Amps O Cond lit and Corductor Schedde Tag Desgiption Wire Gauge #of Conductors:Conduit Type,Condi,il Size :1 Enphase engage cable - THWN-2 12 AWG 4 N,·A -Free Air N/A - Free Air 1 Bare Ctipper Ground (EGC/GEC) 6 AWG 1 N/A - Free All N/A - Free Air 2 THWN-2 10 AWG 3 EMT 0'21" 2 THWN-2 - Ground 8·AWG 1 EMT 01-1 3 THWN-2 8 AWG 3 PVC 0'-1 " 3 THWN-2 - Ground 8 AWG 1: PVC 0'-1 Max Numberof Panels/Circuit 17 NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9) 1.) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS 1 Enphase M215-60-2LL-S2x-ZC SWITCH MEET THE REQUIREMENTS? MICRO-INVERTER AT -YES NO X NA EACH MODULE: ATTACHED 2.) IF GENERATION METER REQUIRED,:DOES THIS METER WITH ZEP HARDWARE SOCKET MEET THE REQUIREMENTS? YES NO X NA 3.) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON SIGN OR OCPD RATING AT DISCONNECT. 4.) SIZE INVERTER OUTPUT (AC) CONDUCTORS ACCORDING MICRO-INVERTER CONNECTION 1 TO INVERTER OCPD AMPERE RATING (See Guide Section 9).ENPHASE ENGAGE TRUNK CABLE- 5.) TOTAL OF 1.- INVERTER OCPD(s). ONE FOR EACH PV CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY ] WITH 120% BUSBAR EXCEPTION X YES NO #6 BARE CU GROUND (GROUNDING ARRAY)Signs (See Guide Section 7) Sign for inverter OCPD and AC Disconnect:If Main Disconnect is Solar PV System AC Point of rated less than the Connection Busbar rating: AC Output Current 19.125000 Amps "Caution-Solar Nominal AC Volt.240 Volts Connection. Do Not increase size of main ' THIS PANEL FED BY MULTIPLE SOURCES disconnect" (UTILITY AND SOLAR) PV Module Ratings @ STC (Guide Section 5)(D -2 E Model Make/Model Yingli) Energy YL250P-29b E C·gl 0 $<EMax Power-Point Current (Imp)8.11 Anips O 3 9-z Max Power-Point Voltage (Vmp)30.2 Volts Al -/i D Open-Circuit Voltage (Voc)37.8 Volts ..00 1.0 w' 5 20 Short-Circuit Current (Isc)8.65 Amps a) (D %< Max Series Fuse (OCPD)15 Amps E un Nominal Maximum Power!at STC (Pmax)240 Watts m 2 Maximum System Voltage 1000(IEC)/600(UL) 5 Voc Temperature Coefficient -0.33 %26 NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): 1.) Lowest expected ambient temperature based on ASHRAE minimum mean extreme dry bulb temperature for ASHRAE location most similar to installation location. -1.5°C 2.) Highest continuous ambient temperature based on ASHRAE highest month 2% dry bulb temperature for ASHRAE location most similar to installation location· 37°C 3.) 2005 ASHRAE fundamentals 2% design temperatures do not exceed 47°C in the United States (Palm Springs, CA is 44.1'C). For less than 9 current-cartying conductors in roof-mounted sunlit conduit at least 0.5" above roof and using the outdoof design temperature of 47°C or less (all of United States). a.) 12 AWG, 90''C conductors are generally acceptable for modules with Isc of 7.68 Amps m or less when protected by a 12-Amp or smaller fuse.0 b.) 10 AWG, 90°C conductors are genetally acceptable for modules with Isc of 9.6 Amps a01 or less when protected by a 15-Amp or smaller fuse.0- A .. C NOTE: ALL PLACARDS SHALL HAVE A RED BACKGROUND,47- MINIMUM 3/8" LETTER HEIGHTS, ALL CAPITAL- LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE WEATHER MATERIAL SUITABLE FOR THE ENVIROMENT.e>55 '8Y':4,4 0) 20 0 -***fro. t.Cd , .• AJJ-4 0- I•.Llj 4 POINT OF DELIVERY ,g@-t,¢136Gy,t. oram 2- k €2 - I . -9 0 # / PV CIRCUIT 1: 17 MODULES/PARALLEL - 0 [=) 4340 e AND INTERCONNECTION %50°·&?· 8731€*.•f 4 $A 0--00 CP **',rea CorM*>4,,'tl VISIBLE/.LOCKABLE 'KNIFE' A/C DISCONNECT 1 EXISTING 240V/100A 4 LOAD-CENTER »>0/1CE.ilin SHEET NAME: 20& 1=3Nll-L DIAG,R, Y Siemens # LNF222R/3-1 /2/ 60A/240v < NOTE: NEUTRAL CONDUCTOR(S) OMITTED FOR CLARITY \\Ey JUNCTION/ UNFUSED ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR.BOX NEMA3 WARNING LABELS WITH WHITE LETTERS/RED BACKGROUND WILL BE PROVIDED ON A/C DISCONNECT SHEET NUMBER: E 1.0/In . i M, D-2-jq 3 117 2 lo(,-* LOCY /co 3 *20 r 4 i 1 i %4'b Photo-voltaic Placard Labels All labels have red back grounds with white lettering. All labels are made of reflective, weather resistant material that is suitable for the environment. All labels appear on this sheet as they·would appear posted on equipment. A WARN Al G Property of Vivint Solar TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKIG ISDE PANEL Listed on Junction Boxes and Main Panel This solar photovoltaic system anti its components are the sole personal property of Vivint Solar- SOLAR BREAKER DO NOT RELOCATE .listed ;on Disconnect Listed on PV Breaker WARNING DUAL POWER SOURCE property of \Avint Solar SECOND SOURCE IS PV SYSTEM PHOTOVOLTAIC BROPERTY OF-VIVINT SOLAR AC DISCONNECT Listed on Main Panel Listed on Disconhect 'PHOTOVOLTAIC AC DISCONNECT Riopedy *f Mitint Solah ' Y. MAX. AC OPERATING CURRENT: PHOTOVOLTAIa*HSCONNECT_ -i MAXIMUM AC OPERATIiNG CURRENT: NOMINAL:OPERATING ACVOLTAGE Listed on Discenhect Listed on Discohnect W Listed on all conduit 3/29/2014 3637872 - Zepulator ZepSolar Bill Of Materials And Layout 3637872 Name:Street Address: 3118 S Lowell St Email:Suite/PO#: Phone:City, State., Zip: Santa Ana, California 92707 Country: UAited States System Details Module Manufacturer PVModule Quantity of PVModules Array Size (kW) Yingli Solar YL250P-29b 14 3.500 Mounting System Manufacturer Mounting System Type Rooftype Attachment Type Module-level electr.onics Zep Solar ZS Comp Composition Shihgle Comp Mount, Type C Enphase Energy - M215-Z http:/Nwm.zepulator.com/projects/52842/summary'bomiprint 1/3 4 3/29/2014 3637872 - Zepulator Bill of Materials Core Components Part Description Quantity YL250P-29b Yingli Solaf YI250 P 29b 14 M215 Z 14 850-1184 Leveling Foot 21 850-1448 DC Wire Clip 56 850-1209 Enphase Connector Br.acket 14 850-1178 Interlock 14 850-1172 Ground Zep 1 850-1361 Array Skirt, black 5 850-1421 Grip 10 850-1405 End Cap 5 850-:1345 Comp Mount, Type. C 21 850-lli96 Universal Box Bracket 1 Tools Part Description Quantity 850-1201 Zep Tool 2 850-1199 Zep Flat Tool 1 http:/Awm.zepulator.com/projects/52842/summary'bom_Print 2/3 -4 3/29/2014 3637872 - Zepulator Layout The following array drawing'represehts the Zep System default materials configuration. The layout and BOM is based on the Interior zone;spacing. If modules fall in other zones please revise your BOM accordingly. -a - 24,00 10.42 http:#mm.zeputator.com/projects/52842/summarybom_print:3/3 4 3/29/2014 3637872 - Zepulator ZepSolar Bill Of Materials And Layout 3637872 Name:Street Address: 3118 S Lowell St Email:Suite/PO#: Phone:City, State, Zip: Santa Ana, California 92707 Country: United States System Details Module Manufacturer PVModule Quantity of PV Modules Array Size (kW) Yingli Solar YL250P-29b 2 0.500 Mounting System Manufacturer Mounting System Type Rooftype Attachment Type Module-level electronics Zep Solar zs comp Camposition Shingle Comp Mount, Type C Enphase Energy - M215-Z http:l/*m,zepulator.col·n/projects/52842/summary'bom_print 1/3 11 3/29/2014 3637872 - Zepulator Bill of Materials Core Components Part Description Quantity YL250P-29b Yingli Solar Yi250 P 29b 2 M215 Z 2 850-1397 Leveling Foot 4 850-1448 DC Wire Clip 8 850-1209 Enphase Connector Bracket 2 850-1388 Interlock 2 850-1172 Ground Zep 1 850-1371 Afray Skin, black 1 850-1421 Grip 2 850-1405 End Cap 2 850-1345 Comp Mount, Type C 4 850-1'196 Universal Box Bracket 1 Tools Part Description Quantity 850-1201 Zep Tool 2 850-1199 Zep Flat Tool 1 http:/4MN.zepulator.coniprojects/52842/summaryiborniprint 2/3 3/29/2014 3637872 - Zepulator Layout The following array dfawing represents the Zep System default materials configuration. The layout and BOM is based !on the Interior zeneispacing. If modules fall in other zones please revise your BDM accordingly. . 1 19.00 11.46 http://vwm.zepulator.cor€projects?52842/summarifbom_print 313 3/2W2014 3637872 - Zepulator ZepSolar Bill Of Materials And Layout 3637872 Name:Street Address: 3118 S Lowell St Email:Suite/PO#: Phone:City, State, Zip: Santa Ana, California 92707 Country: United States System Details Module Manufacturer PVModule Quantityof PVModules Array Size (kW) Yingli Solar YL250P-29b 1 0.250 Mounting System Manufacturer Mounting System Type Rooftype Attachment Type Module-level electronics Zepi Solar ZS Comp Composition 'Shingle Comp Mount, Type C Enphase Energy - M215-Z http:/A,ww.zepulator.corn/projects/52842'summarifbom_print 18 3/29/2014 3637872 - Zepulator Bill of Materials Core Components Part Description Quantity YL250P-29b Yingli Solar YI250 P 29b 1 M215 Z 1 850-1184 Leveling Foot 4 850-1448 DC Wire Clip 4 850-1209 Enphase Connector Bracket 1 850-1178 Interlock 1 850-1172 Ground Zep 1 850-1361 Array Skirt, black 1 850-1421 G rip 2 850-1405 End Cap 2 850-1345 Comp Mount Type C 4 850-1196 Univefsal Box Bracket 1 Tools Part Description Quantity 850-1201 Zep Tool 2 850-1199 Zep Flat Tool 1 http:/Awm.zepulator.com/projects/52842/surrimarybom_print 2/3 1, 3/29/2014 3637872 - Zepulator Layout The following array drawing represehts the Zep System default materials configuration. The layout and BOM is based on the Interior zone spacing. If modules fall in other zones please revise your BOM accordingly. 24.00 16.96 http:#vwm.zepulator.corn/projects/52842/summarybom-print 3/3; Customer AR Customer ddress 3637872 3118 S Lowell St Santa Anai CA Utility Company Name Utility Account Number Electfical Meter Number Estimated Annual CONSUMPTION Estimated Annual PRODUCTION SCE 3-009-1949-35 222013-570883 5674.5 5755 Offset: 101.4% Number of Panels Total System Size/DC Source Rating/Total Array Output (DC Watts) Irnverier Ampere Rating (Amps AC) Number of Phases Inverter Voltage Rating Nominal DC Volts Inverter Power Factor (96) Module Manufactuferand Model Number Power'Rating per Module (DC Watts) Inverter Manufacturer and Model Number l'nverter Continuous AC Rating (AC Watts) Inverter Peak'Efficiency (96) 17 4250 0.9 1 240 30.2 0.95 Yingli Energy YL250P-29b 250 Enphase M215-60-2LL--522 215 96.3% Totals Number of Modules/Inverters System Size/DC Source Rating/Array Output (DC Watts) Total Inverter Ratihg (kW AC) Total Inverter Output (AC Watts) Estimated Production Building Permit Valuation Electfical Permit Valuation Total Valuation @ $5.00/Watt:5.00 17 4250 0.215 215 5755 $ 850.00 $ 20,400.00 $ 21,250.00 $ 21,250.00 Building Pefmit Valuation per watt $ 0.20 Electrical Permit Valuation per watt $ 4.80 Constraint:USAGE Customer Estimated Monthly Usage:(Total annual usage: 5674.5 kWh) January February March April 589 420 496 390 May lone July August 387.5 450 418.5 403 September October November December 450 449.5 570 651 4 Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Proiect Information Project Name:ERIC DALNES Projecti Address:3118 S Lowell St, Santa Ana CA A. System Description: The array consisi·s o f a 1.25 kW DC roof-mounted Phdtovoltaic power system operat·ing in parallel with the utility grid. There are (17) 250-watt modules and (17) 215-wat·r micrig-inverters, inounted on rhe [racl< of each PV module. The animy includes (1) PV circuii (s). The array:is mounced to the oofusing the engineered racking solui:ion froin Zep Solar. B. Site Design Temperature: Average low ternperature Average high temperature: (From Fu'llerton Municipal AP weather station) 0.9 °C (33.62 °19 40.9 °C (105.62 OLD C. Minimum Design Loads: Ground Snow Load:0 pa (ASCE 7-10(7.2)) Design Wind Speed:100 mph (ASCE 7-10(26.5 1)) 2. Structural Review of PV Arrav Mounting Svstem: A. System Description: 1.R,-,r, f r.ype 2. Method and t.ype of weacherproofingroofpenetrations: Comp. Shingle Flashing B. Mounting System Information: 1. Mounting system is an engineered product designed to mount P.V modules 2. For. manufact:uted mounting systems, followinginfermation applies: a. Mount:ing Sys[·cm Manufacturer:Zep Solar b. Product Name:ZS Comp e. Total Weighi. of PV Modules and mounting hafdwarb:715.8 lbs d. Total nurnber o f attachment points: 29 c. Weight per attachment point:24.68 lbs/square foot f. Maximum spacing between airachment points: *See attached engineering calcs g. Total surface area of PV :11·r:ir:297.98 square feet h. Arm- Pounds pEr squ:irc foot:2.4 Ibs/square foot i. Distribi,ied weiglic of PV artat on reef- sections: -Roofs=cdon I:(14) moduler, (21) atuchments 28.07'pounds per square foot -Roof section 2 (3) modules, (8) airachm,nts 15.79 pounds per square fuor Vivint 6 7. 4 3. Electrical Components: A. Module (UL 1703 Listed) Yingli Energy- YL.250P-29b Qty 17 modules Module Specs Pmax - nonlinal >maximum powet: at STC Vinp - rat:ed ve][age at maximum power Voc - rated open-circuit voltage Imp - rated current at maximum power Ist- race ishort circuit current 250 watts 30.2 volts 37:8 vofts 8.11 amps 8.63 amps B. Inverter (UL 1741 listed) Enphast M215-60-2LL-S22 Qty 17 inverters Inverter Specs 1. Input Data (:DC in) Recommended input power (DC) -260 ward Max. input DC Voltage -45 volts Peak power tracking vc)]rage -22V - 36V Min./Max. start voirage -22V/45V Max. DC shorr circuit current -15:imps Max. inpuT current -10.5 amps 2. Output Data (AC Out) Max. output power -215 watts Norninal output current .0,9 amps Nominal veltage 240 volts Max. units per PV circuit -17 micro-inverters Max. OCPD rating -20 amp circuit breaker C. System Configuration Numbeu: of'PV eireti'ts 1 PV circuit 1 -17 modules/inverters (20) amp breaker Vivint D. Electrical Calculations 1. PV Circuit current PV circuir nominal current Continuous current adjustment factor PV circuit continuozi: curren[ rating 15:.3 amps 125% 19.125 amps 2013 CEC Article 705.60(B)) 2. Overcurrent protection device rating PV'circuit continuous current rating Next standard sjze fuse/breaker Ed prorec[ conducroIs 'li9.125 amps 20 amp breaker Use 20 amp AC rated fuse or breaker 3. Conductor conditions of use adjustment (conductor ampacity derate) a. Temperature adder Average high remperature 40.9 '°.C (105.62 °19 Conduit is installed 1"'above the roof surface .Add 22 °C to ambient Adjusted maximum ambient temperature 62.9 °C (145.22°p) 2013 CEC Table 310.15(B)®(a) b. PV Circuit current adjustment for new ambient temperature Derate factof for 62.9 ec 045.22°P)58% Adjusted PV circuit continuous current 32.9 amps 2013 GEC Table 310.16 (boriom of cble) c. PV Circuit curfent adjustment for conduit fill Number of current-carrying conductors Conduit Till deratle factor Final Adjusied PV circuit continuous current 3 cooductors 100°Z, 32.9 amps 2013 GEC Table 310.15(B)(2)00 Total derated ampacity for PV circuit 32.95amps Conductors (tag2 on 1-line) must be rated for a minimum of 32.9 amps THWN-2 (90 °C) #10AWG conduttor is rated for 4.0 amps (Use #10AWG or larger)2013 CECTable 310.16 4. Voltage drop (keep below 3% total) 2.porrs: 1. Voltage drop across longest PV circuit micro-inverters (from modules to i-box) 2. Vo[[age drop across AC conducrors (from j-box co point e finterconneccion) 1. Mirco-invertcf voliage drop:0.24% The largest nufnber o f micro-inverrers ina row in theent:ire array is 7 inCircuit 1. According to manufaciurer'.i specifications this equals a foltage drop of 0.24 %. 2. AC corductor vololgc drop: = Ix R x D (+ 240 x 100 0 conver[ to percent) = (Nominal current of laogest circui 0 x (Resistance of #10AWG coppet) x (Total wire run) = f.Circu.it 1 norninal current is 13.3 , nps) x (0.00126@x (1 305 + @40 volts) x BOO)1.04% Total system voltage drop:1.28% Vivint -1.- EA 3/29/2014 3637872 - Zepulator ZepSolar Enigineering Calculations 3637872 Name:Street Address: 3118 S Lowell St Email:Suite/PO#: Phone:City, State, Zip: Santa Ana, California 92707 Country: United States System Details; Module Manufacturer PV Module Quantity of PV Modules Array Size (kW) Yingli Solar YL250P-29b 14 3.500 Mounting System Manufacturer Mounting System Type Rooftype Attachment Type Module-level electronics Zep Solar ZS Comp Composition Shingle Comp Mount: Type C Enphase Energy - M215-Z http://vwm.zepulator:com/projects/52842/summaryeng ineering_print 1/4 3/29/2014 3637872 - Zepulator Engineering Calculations Design Variables Description (Symbol)Value Unit Module Orientation Landscape Module Weight 45.2 lbs Average Roof Height (h)15.0 A Least: Horizontal Dimension (lhd)30.0 ft Edge and Corher Dirnehsion "a"3.0 ft Roof Slope (8)23.0 deg RaftenTruss spacing 24.0 in Rafter/Truss dimehsion Min. nominal framing member depth of 4: Basic Wind Speed (V)110 mph Exposure Category B Ground Snow,Load (Pg) 0 Dsf Risk Category 11 Topographic Factor (Kzt)1.0 Thermal Factor for Snow Load (Ct)1.2 Exposure Factor for Snow Load (Ce)0.9 Effective Wind Area 10 *2 Snow Load Calculations (Using calculation procedure of ASCE 7-10 Chapter 7) Description (Symbol)Interior Edge Corner Unit Flat Roof Snow Load (Pf)0.0 0.0 0.0 psf Slope Factor (Cs)0.9 0.9 0.9 Roof Snow Load 0.0 0.0 0.0 psf Wind Pressure Calculations. (Using simplified procedure of ASCE 7-10 Chapter 27) De scription (Symbol)Interior Edge Corner Unit Net Design Wind Pressure uplift (Pnet3O_up)-19.9 -34.7 -51.3 psf Net Design Wind Pressure doymforce (Pnet30__down)12.5 12.'5 12.5 psf http:/Nwm.zepulator.corn/projects/52842/summary/engineering_print 2/4 3/29/2014 3637872- Zepulator Adjustment Factor for Height and Exposure Category (A) 1.0 1.0 1.0 Design Wind Pressure uplift (Wup)-19.9 -34.7 -51.3 psf Design Wind Pressure downforce (Wdown)16.0 16.0 16.0 psf AS.D Load Combinations (Using calculation procedure of ASCE 7-10 Section 2.4) Description (Symbol)Interior Edge Corner Unit Dead Load (D)2.6 2.6 2.6 psf Snow Load (S) O.0 0.0 0.0 psf Load Combination 1 (D+0.7570.6*Wdown)+0-759 9.6 9.6 9.6 pdf Load Combination 2 (D+0.6*Wdown)12.0 12.0 12.0 psf Load Combination 3 (D+S)2.4 2.4 2.4 psf Uplift Design Load (0.6*D+0.6'Wup)-10.5 -19.4 -29.4 psf; Maximum Absolute Design Load (Pabs)12.0 12.0 12.0 psf Spacing Calculations Description (Symbol)Inte rior Edge Corner Unit Max allowable spacing between attachments 7.2.0 72.0 72.0 in User selected spacing between attachments given a rafter/truss spacing of 24.0 in 72.0 7:2.0 72.0 in Max cantilever from attachments to perimeter of PV array 24.0 24.0 24.0 in Distributed and Point Load Calculations (In conformance with Solar ABC's Expedited Permit Process for PV System (EPP)) Description (Symbol)Value Unit Weight of Modules 632.8 lbs Weight of Mounting System 48.97 lbs Total System Weight 681.77 lbs' Total Array Area 246.18 ft@ Distributed Weight 2.77 pdf Total Number of Attachments 21 Weight: per Attachfnent Point 32.47 psf http:#wwN.zepulator.corn/projects/52842/summary/engineering_print 3/4 3/29/2014 3637872 - Zepul ator hip://\A,m.zepulator.corn/projects/52842/summaryeng ineeriAg_print 4/4 3/29/2014 3637872 - Zepul ator 0, ZepSolar Engineering Calculations 3637872 Name:Street Address: 3118 S Lowell St Email:Suite/PO#: Phone:City, State, Zip: Santa Ana, California 92707 Country: United States System Details Module Manufacturer PVModule Quantity of PV Modules Array Size (kW) Yingli Solar YL250P-29b 2 0.500 Mounting System Manufacturer Mounting System Type Roof type Attachment Type Module-level electronics Zep Solar ZS Comp Composition Shingle Comp Mount, Type C Enphase Ehergy - M215-Z htp://Owm.zepulator.dom/projects/52842/sumniary/engiheerihig-print 1/4 3/29/2014 3637872 - Zepulator Engineering Calculations Design Variables Description (Symbol)Value Unit Module Orientation Portrait Module Weight 45 2 lbs Average Roof Height (h)15.0 ft Least Horizontal Dimension (Ihd)30.0 ft Edge and Corner Dimension "a"3.0 ff Roof Slopeite)23.0 deg Rafter/Truss spacing 24.0 in Rafter/Truss dimension Min. nominal framing member depth of 4 Basic Wind Speed (V)110 mph Exposure Category B Ground Snow Load (Pg) 0 W Risk Category 11 Topographic Factor (Kzt) 1.0 Thermal Factor for Snow Load (Ct)1.2 Exposure Factor for Snow Load (Ce)0.9 Effective Wind Area 10 M Snow Load Calculations (Using calculation procedure of ASCE 7-10 Chapter 7) Description (Symbol)Intefiof Edge Corner Uhit Flat Roof Snow Load (Pr)0.0 0.0 0.0 Psf Slope Factor (Cs)0.9 0.9 0.9 Roof Snow Load 0.0;0.0 0.0 psf Wind Pressure Calculations (Usihg simplified procedure of ASCE 7-10 Chapter 27) Description (Symbol)Interior Edge Cother Unit Net Design Wind Pressure ublift (Pnet30_up)-19.9 -34.7 -51.3 psf Net Design Wind Pressure downforce (Pnet30_dawn)12.5 12.5 12.5 psf http:/Nwm.zepulator.com/projects/52842/summaryfeng ineering_print 24 3/29/2014 3637872 - Zepulator Adjustment Factor for Height and Exposure Category (A)1.0 1.0 1.0 Design Wind Pressure uplift (Wup)-19.9 -34.7 -51.3 psf Design Wind Pressure downforce (Wdown)16.0 16.0 16.0 psf ASD Load Combinations (Using calculation procedure of ASCE 7-10 Section 2.4) Description (Symbol)Interior Edge Corner Unit Dead Load (D)2.6 2.6 2.6 psf Snow Load (S) 0.0 0.0 0.0 psf Load Combination 1 (D+0.7570.6*Wdown)+0.75*S) 9.6 9.6 9.6 psf Load Combination 2 (D+0.6*Wdown)1:2.0 12.0 12.0 p. sf Load Combinatibn 3 (D+S)2.4 24 2.4 psf Uplift Design Load (0.6*D+0.6*Wup)-10.5 -19.4 -29.4 w Maximum Absolute Design Load (Pabs)12.0 12.0 12.0 psT Spacing Calculations Description (Symbol)Inte rior Edge Corner Unit Max allowable spacing between attachments 72.0 72.0 49.0 in User selected spacing between attachments given a rafter/truss spacing of 24.0 in 72.0 72.0 48.0 in Max cantilever from attachments to perimeter of PV array 24.0 24.0 1 640 in Distributed and Point Load Calculations (In conformance with Solar ABC's Expedited Permit Process for PV System (EPP)), Description (Symbol)Value Unit Weight of Modules 90.4 lbs Weight;of Mounting System 8.95 lbs Total System Weight 99.35 lbs Total Array Area 35.117 ft2 Distributed Weight 2.82 W Total Number of;Attachments 4 Weight pdf Attachment Point 24.84 psT httpi/Awm.zepulator.com/projects/52842/sumniary/engiheeringa.print 3/4 3/29/2014 3637872 - Zepulator http:/hwm.zepulator.conl/projects/52842/summary/eng ineeri ng_print . 3/29/2014 3637872.- Zepulator ZepSolar Engineering Calculations 3637872 Name:Street Address:.3118 S Lowell St Email:Suite/PO#: Phone:City, State, Zip: Santa Ana, California 92707 Country: United States System Details Module Manufacturer PVModule Quantity of PV Modules Array Size (kW) Yingli Solar YL250P-29b 1 0.250 Mounting System Manufacturer Mounting System Type Rooftype Attachment Type Module-level electronics Zep Solar ZS Comp Composition Shingle Comp Mount. Type C Enphase Energy - M215-Z http:/A,ww.zepulator.corn/projects/52842/summary/ehgineering_print 1/4 3/29/2014 3637872 - Zepulator Engineering Calculations Design Variables Description (Symbol)Value Unit Module Orientation Landscape Module Weight 45.2 lbs Average Roof Height (h)15.0 ft Least Horizontal Dimension (Ihd)30.0 ft Edge and Corner Dimension "a"3.0 ft Roof Slope (0)23.0 deg Rafter/Truss spacing 24.0 in Rafter/Truss dimension Min. nominal framing member depth of 4" Basic Wind Speed (V)110 mph Exposure Category B Ground Snow Load (Pg) 0 psf Risk Category 11 Topographic Factor (Kzi) 1.0 Thermal Factor for Snow Load (Ct)1.2 Exposure Factorrfor Snow Load (Ce)0.9 Effective Wind Area 10 M Snow Load Calculations (Using calculation procedure of ASCE 7-10 Chapter 7) Description (S¥mbol)Interior Edge Corner Un it Flat-Roof'Snow Load (Pt)0.0 0.0 0.0; psf Slope Factor CCS)0.9 0.9 0.9 Roof Snow Load 0.0 0.0 0.0 psT Wind Pressure Calculations (Usihg simplified procedure of ASCE 7-10 Chapter 27) Description (Symbol)Interior Edge Corner Un it Net Design Wind Pressure ubljft (Pnet30_up)-19.9 -34.7 -51.3 psf Net Desi¢in Wind Pressure downforcea<Phet3O (IowA)12.5 li2.5 12.5 psf http:/Nwm.zepulator.com/projects/52842/summary¢eng ineeting_print 2/4 3/29/2014 3637872 - Zepulator Adjustment Factor for Height and Exposure Category (A)1.0 1.0 1.0 Design Wind Pressure upiift (Wup)-19.9 -34.7 -51.3 psf Design Wind Pressure downforce (down)16.0 16.0 16.0 psf ASD Load Combinations (Using calculation procedure of ASCE 7-10 Section 2.4) Description (Symbol)Interior Edge Corner Un it Dead Load (D) 2.6 2.6 2.6 psf Snowload (S) 01.0 0.0 0.0 posf Load Combination 1 (D+0.7570.6*Wdown)+0.75*S)9.6 9.6 9.6 psf Load Combination 2 (D+0.6*Wdown)12.0 12.0 12.0 psf Load Combination 3 (D+S)2.4 2.4 24 psf Uplift Design Load (0.6*D+0.6*Wup)-10.5 -19.4 -29.4 psf Maximum Absolute Design Load (Pabs')12.0 12.0 12.0 psf Spacing Calculations Description (Symbol)Interior Edge Corner Unit Max allowable spacing between attachments 72.0 72.0 72.0 in User selected sbacing between attachments given a fafter/truss spacing iof 24.0 in 72.0 72.0 72.0 in Max cantilever frbm attachments to perimeter of PV array 24.0 24.0 24.0 in Distributed and Point Load Calculations (In conformance with Solar ABC's Expedited Permit Process for PV System (EPP)) Description (Symbol)Value Unit Weight of Modules 45.2 lbs Weight of Mounting System 8.4 lbs Total System Weight 53.6 lbs Total Array Ar.ea 17.58 M Distributed Weight 3.05 psf Total Number of Attachments 4 Weight per Attacbment Point 13.4 psf http://wvm.zepulator.con«ojects/52842/summaryfeng ineeting_print 3/4 juu.d--Bullau!6ud>Cleujuins/DOE*sioa,[oid/woo·lojeindez·Awwvt:dull ®4eindez - ZZ8Z€9£*LOZ/61/£ YGE 60 YL260P-29b YL255P-29b CELL SERIES YL250P-29b YL245P-29b YL240P-29b YINeijFRFLAR U.S. Soccer Powered by Y ngli Solar YINGL SOLAR YGE SERIES · Our signature product line is a top performer in every application, from rooftop systems to utility-scale power plants. 1 Ii I ii:I BUILT TO PERFORM High performance, multicrystalline solar cells deliver a module series efficiency of up to 15.9%, reducing installation costs and maximizing the kWh output per unit area. Tight positive power tolerance of 0 / +3% ensures modules are delivered at or above rated power, improving system performance through the reduction of module mismatch loss. With proven experience in over 7 GW of projects worldwide, Yingli modules deliver reliable performance in residential, commercial, and utility-scale applications. IPROVEN QUALITY AND RELIABILITY Robust, corrosion resistant aluminum frame independently tested to withstand wind and snow loads of up to 2400Pa and 5400Pa, respectively, ensuring mechanical stability. Independent labs certify that Yingli modules resist the highest levels of ammonia and salt mist, demonstrating their reliable performance in challenging environmental condtions Manufacturing facility certified by TOV Rheinland to the following standards: ISo9001 Quality Management System, ISO 14001 Environmental Management System, and BS OHSAS 18001 Occupational Health and Safety. Leading limited power warranty* ensures 91.2% of rated power for 10 years, and 80.7% of rated power for 25 years. 10-year limited product warranty. ' In compliance with our warranty tenns and conditions UL 1703 and ULC 1703, CEC, FSEC, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007. SA8000 CO!!)us LISTEO AMOIC,VOLTIC,•001/1 4400 If you buy from Yingli Americas.Ying!, Americas acts as the Importerand complies wi*all applicablemr,Es Cuitomerscanbuy from Yingli Amer,15 with no wor™that they will be liable for anyimport tariffs YINGLISOLAR.COM/US Yingli Americas YGE 60 CELL SERIES Powered by YINGLI ELECTRICAL PERFORMANCE GENERAL CHARACTERISTICS Module type 1.57in (4(knm) YL26DP-29b YL255P-29b YL25OP.29b YL.245P-29b YL 240P-29b Dimefisionis (1 /W/Hl 64.96in (1650mm)/38.98in (990mm)/ Power owtput P_ W 260 255 250 245 240 Weight 40.8!bs;08.51<g)Power output tolerince5 AP- 96 -0/+3 Module efficiency qn %15.9 15.6 15.3 15.0 14.7 '/allege Ot Pr,u.V..9 V 30.3 30.0 29.8 29.6 29.3 PACKAGING SPECIFICATIONS Current at P...4 A 8.59 8.49 8.39 8.28 8.18 Number of modules per palld 26 Open-circuit voltage V. V 37.7 37.7 37.6 37.5 37.5 Numbor of palle por 40' antall,6/.6 Short<ircuit current 1. A 9.09 9.01 8.92 8.83 8.75 Packaging box dimensions 67.32in(1710mm)/45.67in (1160mm) (L/W/H) /46.38in (1178mml STC: 1000W/m# inadiance, 25•C cell temperaium, AM 1 5g spectim according to EN 60904-3 Average relative emciency reduction of 3,3% at 2[10W/m2 according,0 EN 60904-1 Box weight 1133[bs (514kg) Electrical oarameters at Nominal Ooeratina Cell Temoerature INC)(11 Units: inch (mm) Power output P... W 189.7 186.0 182.4 178.7 175.1 38.98 (9901 Voltagest Pri,•6- V 27.6 27.4 27.2 27-0 26.8 37.24 (946)1,57 404 Current at P....|rrw A 6.87 6.79 6.71 6.62 6.54 1 Open-circuit,voltage VIc V 34.8 34.8 347 34.6 34.6 W -1- Shon circuit current 1. A 735 7.28 7.21 7.14 NOCT: open<ink operating celltemperawe at 80CW/mZ irradiance. 20'C ambiennemp,fature, lm/6 wind speed 7.07 :4 i THERMAL CHARACTERISTICS Nominal operating dell temperature NOCT •C Temperature coafficlent of Pm.. ¥96/"C Temperaturecoeffident of V. 8- 96/f Temperature coefficient of 6,6 94•C Tarnparature cookient of V.pp 0-- 9W-C 46 +A 2 -0.42 -0.32 0.05 -0.42 LL Groun<Ing hotese 1 1 6.00-236(6) Mounrighclas 2-0.256.0,315 {6.54 OPERATING CO'NDITIONS Max.system voltage Max.;series fuse rating Limiting reverse current Operating temperature range Max. hailstona impact (diameter /velocity) 600Vocor 1000Voc 15A 15A -40 to 1857 640 to 85·C) 25mm /23m/: 04Dramago holes 8-0.12*0.315 (3*8} 2=p 1 .. 14 m 3.94(100) ------ ''' 0,47 1/21 6. CONSTRUCTION MATERIALS 5 SECTON B.-B ; Front cover (material /thickness) Cell (quantity / materlal /dimensions / numbet of busbars) Encepsulant (mater'lai) Frame (material / color /edge scaling) Junction box (ingress protection rating) Cable (length / aoss·sectional ares) Connector (type / ingress pratection rating} low-iron tempered glass /3.2mm 60/ multicrystallinesilicon / 156mm x 156mm / 2 or 3 ethylene vinyl acetate (EVA) anondized aluminum alloy / :ilvcror bldck / Illicone or tape 2IP65 1100mm/'4mm' Mc4 or Amphenol H4 1 iIP67 , I , / / 1.26 (321 Warning: Read the Installation and User Manual in its entirety before handling installing. and operating Ying[i modules. Our Partners The specifications in this datasheet are not guaranteed and are subject to cbange without prior notice, This datasheer complies with EN 50380:2003 requirements Yingli Green Energy Americas, Inc. info@yingliamericas.com Tel: +1 (888) 686-8820 YINIILAR YINGLISOLAR.COM/US I NYSE:YGE ©Yingli Greer Energy Holding Co. Ltd. YGE60CelISerie52013_EN_201309Vol U.5.Soccer Powered by Yingli 5olar IN) ENPH AS E M2'-0-VIICROINVERTER [e] enphaseENERGY The M215-Z Microinverter attaches directly to the frame of Zep Compatible solar modules for seamless integration with the Zep System. Like all Enphase Microinverters, it improves energy harvest, increases reliability, and dramatically simplifies design and management of solar power systems. The Enphase System includes the microinverter, the Envoy Communications Gateway, and Enlighten, Enphase's monitoring and analysis software. enphase.com h. ) e - Maximum energy production PRODUCTIVE -Resilient to dust, debris and shading - Performance monitoring per module - System availability greater than 99.8% RELIABLE - No single point of system failure - Quick and simple design, installation SMART and management - 24/7 monitoring and analysis - Low voltage DC SAFE -Reduced fire risk 0 US W ENPHASE M215-Z MICROINVERTER - TECHNICAL DATA ,Recommended input power (STC) Maximum input DC voltage Peak power tracking voltage Operating fange Min./Max. start voltage Max. DC short circuit current Max. input current Output Data (AC) Maximum output power Nominal output current Nominal voltage/range Extended voltage/range Nominal frequency/range Extended frequency range 1 Power Factor Maximum units per 20A branch circuit Maximum output fault curfent Efficiency 190 - 260W 45V 22V - 36V 16V - 36V 22W45V 15A 10.5A @208 Vac @240 Vac 215W 215W 1.OA Cam*at nominal duration) 0.9A (arms at nominal duration) 208V/183-229V 240V/211-264V 208V/179-232V 240V/206-269V 60.0/59.3-60.5 Hz 60.0/59.3-60.5 Hz 60.0/59.2-60.6 Hz 60.0/59.2-60.6 Hz >0.95 >0.95 25 (three phase)17 (single phase) 1.05 Arms, over 3 cycles. 25.2 Apeak, 1.74ms duration CEC weighted efficiency 96.0% Peak inverter efficiency 96.3% Static MPPT efficiency (weighted, reference EN50530)996% Dynamic MPPT efficiency (fast irradiation changes, referehce EN50530)99.3% Night time power consumption 46mW Mechanical Data Ambienttemperature range Operating temperature range (internal) Dimensions (WxHxD) Weight Cooling Enclosure environmental rating . Features Compatibility Communication Warranty Monitoring Compliance Enphase Energy, Inc. 201 1 st Street Petaluma, CA 94952 Phone: 877-797-4743 Fax: 707-763-0784 info@enphaseenergy.com httpd/www.enphase.com -409C:to + 65°C -40°C to + 85°C 17.3 cm x 16.4 cm x 2.5 cm (6.8" x 6.45" x 1.07 1.6 kg (3.5 lbs) Natural convection - No fans Outdoor - NEMA 6 Pairs with Zep Compatible Modules (60-cell only) Power line 25-year limited warranty Free lifetime monitoring via Enlighten software UL1741/IEEE1547, FCC Part 15 Class B CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01 *without mounting bracket October 25, 2011 Installing the M215 Microinverter (M215-60) Read and follow all warnings and instructions in the M215 Installation and Operation Manual at http://www.enphase.com/support before installing the M215 Microinverter™. Install the Envoy Communications Gateway Install according to the steps in the Envoy Quick insta# Guide. Leave the Envoy running while you install the micfoinverters so that any required Envoy software upgrade completes. Envoy (-03 broadband router Warning: Do not remove power from the Envoy if the LCD displays: "Upgrading. . . Do Not Unplug." AC power 1 cord B Ethernet cable 0 \\ Position the Enphase EngageM Cable a. Lay out the cabling along the' installed racking for the AC branch circuit. terminator - b. Install an appropriately rated, off-the-shelf junction box at a suitable location on the racking./0-21 /h2-9<-) Engage CableSee notes in Step Details on back. 6 AC junction box . 2*6 drop conr 49 0 \cable ties Cld¢t. connects to drop connectors M215 DC connectors Check the drop connector labels to be sure that you have the right cable. You must wse 240 VAC cable for single phase or 208 VAC cable for three-phase. 120® Cul M21 5 Microinverter Quick Install Guide Attach the Microinverters to the PV Racking a. Mark the approximate centers of each PV module on the PV racking. See notes in Step Detai/s on back. 4 0, V...,053 b. Mount the microinverters under the PV module, away from rain and sun. Do not mount the microinverter in a position that allows long-term exposure to direct sunlight or in a vertical orientation that allows water to collect in the DC connector recess. c. Torque the microinverter fasteners as follows: • 5Nm (45-50 in-lbs) for 6 mm (1/47 hardware • 9Nm (80-85 in-lbs) for 8mm (5/16") hardware Ground the System a. Route a continuous GEC (grounding electrode conductor) through each of the microinverters to the NEC-approved AC grounding electrode. See notes in Step Detai/s on back. b. Torque each 10/32 grounding cleat screw to 2 N m (20-25 in-lbs). f # 0 0 0 0 "k GEC- Dress the Cable a. Attach the cabling to the rack using cable clips or tie wraps. b. Dress any excess cabling in loops so that it does not contact the root. cable clip release ho/es Keep the drop /1 connector release holes /-2,4t?j clear and i.-'' accessible. i Connect the Microinverters a. Remove and discard the temporary shipping cap from the cable connector and connect the microinverter. Usten for two clicks as the connectors engage. ' F ==1 ' b. Cover any unused connectors with sealing caps. Listen for two clicks as the connectors engage. See notes in Step Details on back. 9- L nmi inrlinn 1 /r=h cleat \7)Do not use shipping caps to cover unused connectors. The shipping cap does not provide an adequate environmental seal. (J) Terminate the Unused End of the Cablea. Remove 60 mm (2.5") of the cable sheath from the conductors. -1 b. Check that all terminator parts are present. hex Wire nut organizer l l c. Slide the hex nut onto the cable. d. Insert the cable end all the way into the wire organizer (up to the stop). e. Attach the cap. bend wires down - into recesses of wire organizer and trim to length . place cap over the wire organizer 1 - ho/d the cap ·. . 77 with the of/scon- ned tool or a #2 screwdriver d'' j! 19 ,rotate the hex nut 1 21,0- with your hand or.> N.»\01 a wrench until the latching mechanism meets the base-do not over torque f. Attach the terminated cable end to the PV racking with a cable clip or tie wrap. 0 0/%53/6 ) Connect the Cable to the AC Junction Box Connect the cable into the AC branch circuit junction box. See notes in Step Detai/s on back. Complete the Installation Map Build the map manually, or you can use the ArrayGun feature from the Enphase Installer Toolkit to build the system. For more information, go to http://enphase.com/products/arravgun/. To manually build the map, peel the removable se- rial number label from each microinverter and affix ill to the respective location on the map included with this guide. -/ =2==LIZE-serial - number /abets -1-1 Connect the PV Modules a. Mount the PV modules above the microinverters. b. Connect the DC leads of each PV module to the DC input connectors of their corresponding microinverter. 60-cell PV module verify polarity on at least one unit pair Of'J cap 0 Never unscrew the hex nut. This action can twist and damage the cable. . -4 11 Energize the System a. Turn ON the AC disconnect or circuit breaker for the branch circuit, b. Turn ON the main utility-grid AC circuit breaker. Your system will start producing power after a five-minute wait time. --. status LEDt ., One minute after DC power is ap- plied, the status LED on the under- side of each M215 will blink green six times to indicate normal start up. Next Step Refer to the Envoy Communications Gateway Quick /nsta# Guide for information on Envoy® installation and Eniighten® access. Step Details 0 NOTE: Verify that AC voltage at the site Ts within range: 240 Volt AC Split Phase 208 Volt AC Three Phase Ll to L.2 211 to 264 VAC Ll to L.2 to L3 183 to 229 VAC Lli L2, to N 106 to 132 VAC Ll. L.2, L3 to N 106 to 132 VAC WARNING: Only use electrical system components approved for wet locations. WARNING: Do NOT exceed the maximum number of micro- inverters n an AC branch circuit as listed in the table below. Each branch circuit must be protected by a dedicated circuit breaker ot 20 A or less. Service type Max M215s per branch 240 VAC split phase 1 7 208 VAC three phase 25 WARNING: Size the AC wire gauge to account for voltage drop for both the branch circuit and all upstream conductors leading back to the PCC. See Circuit Calculations for /0215 at http:// www.enphase.com/support. 0 WARNING: Allow a minimum of 1.9 cm (0.75") between the roof and the microinverter. Also allow 1.3 cm CO.50") between the back ot the PV module and the top of the microinverter. NOTE: Torque the microinverter fasteners to the values shown. Do not over torque: • 6 mm (1/4") mounting hardware -5 Nm (45-50 In-lbs) • 8 mm (5/161 mounting hardware -9 Nm (80-85 in-lbs) Using a power screwdriver is not recommended due to the risk of thread galling. 0 NOTE: The AC output neutral is not bonded to ground inside the microinverter, NOTE: The M215 grounding cleat can accommodate a 6 to 8 AWG conductor. Torque the 10/32 grounding cleat screw to 2 N m (20-25 in-lbs). Do not over torque. Using a power screw- driver is not recommended due to the risk of thread galling. 0 WARNING: Install scaling caps on all unused AC connectors as these become live when the system iq energized by the utility The IP67-rated T disconnectsealing caps are required for tool protection against moisture ingress. NOTE: To remove a scaling cap, you must use the Enphase disconnect tool a #2 Philiips screwdriver. 0 Enphase Energy, Inc. 1420 N. McDowell Blvd. Petaluma, CA 94954 USA info@enphaseeriergy com http://www.enphase.corn NOTE: The Engage Cable uses the following wiring scheme. 240 Volt AC, Split Phase Wiring 208 Volt AC, Three Phase Wiring Blact< - Ll Black-Ll Red - L2 Red - L2 White - Neutral Blue - 1-3 Green - Ground White - Neutral Greeri - Ground C US © 2013 Enphase Energy Inc. All rights reserved. 00 ZepSolar ZSComp ZS Comp™ from Zep Solaroffers the fastest and least expensive way to mount PV arrayson composition shingle roofs. With a series of drop-in and quarter-turn connections, ZS Comp offers real [aborsavings compared toconventional mountingsystems. The structural connections of ZS Comp are auto-grounding, eliminating the need for separate grounding hardware. And with its hyper-bonded ground ng matrix, ZS Comp offers the safest, most reliable way to ground PV arrays. Key System Benefits Key Technical Features Drarnalica tty reduces inslallation TUV tested zo IEC 61215 for 5400Pa time load conditions Eliminates mountirig rails and clip Suitable forhigh wind applications hardware Interlock El L listed to UL I 103 as Eliminates separate groundlig ground bondmeans hardware Ground Zep UL and ETL listed to UL U.tra-reliable hyper bonded 467 as grounding and bonding device grounding matrix --- -- - -- - -- -- - Intertock, Leveling footand Ground Rapid, too-accessible precision Zep listed to UL 2703 Eis PV bond,ng array leveling device Ultra-low parts count Enhanced aesthetics Datasheet: /.S Comp Zep Compatible" ZS Comp mounting hardwareis designed for use with Zep Compatibler. PV modules from leading PV module manufacturers' Visit zepsolar.com for a current list of Zep Compatible™ PV modules. Our Other Product Families ZS Aero ZS Seam ZS Span ZSTile ZS Trap ZS Wave Page 1 Of 2 COMp,0 LISTED Datasheet: ZS Comp Components Interlock V.(203 ,(34) e The Intertock trowdes north-south ung easi west structural and ground bond con,recilons creating a structurally contiguous hyper banded array. Interlock UL lisled to UL 2?03 and ET. listed to UL I703 Leveling Foot 40 AA apparatus and altow& for 22%y aftaY height adjustment (125' throw) UL listed to UL 2703 Comp Mount Type C Ground Zep n -tull all lr™n 26 9mm rheGround Zep frovidesa point o f connection betwieen the PV arra,and the equipment grounding conductor One Grcund Zep is required for every 72 PV modules t)Land ETL 1,ted to WL 467 1 fi listed te l 1 2703 Universal Box Bracket DC Wire Clip Grip The Universal Box Bncket atiows rapid attachment 04 eler trical !10<05 to the mollule frame Clips into Zep Groove for ultra-fast and easy management of OC PV wiring Leve ing Feet or Cam Feet UL isted to UL 2703 Array Skin End Cap Tools The Array Ski, t facilitates PUSV frofit row wriSt<(13(101 while Drovidiflg a clean look al the front of tne PV array Ill listed to Ut 2703 The End Cap provide:. an destfietic cover for the exposed end of the Array Skirt Made of anodized aluminum Ultisted leUL 2703 Zeo Too! 4 (unctions. 1 tool Flat 1'003 Rjr ' fiter modi,keremoval his Meurn,FN does MI cre@e gar Boles, •afflati liylfu SDIW HT iblul Its Wad,rl. M Mvtm ZED Sll|drs 1 *d afflY £ M 12,026 m Ine w,11 en wom,il wri,ly for e cll ''GL] '1<CIC JUCESMIRCOMgIllf '01 r.1 R I091]48 J:; Parent /16]13.65<15 & IM I Palf?hir Fultlm# L@51 11%03[e J.i y H 201] 10 15 AM Page 2 of 2 7.epSol, ar ZS Comp™Need Help?Quick Start If // USTechnica[Support www,zepsolar.com +1 (415) 230-2096 Support Manuals ,-.4 support@zepsolar.com Videos Training www.zepulator.com Zepulator online design tool Components Notice Tools and Accessories This Quick Start Guide 15 intended to provide a quick introduction to the standard installation procedure for the Zep Solar' roottop mounting solution ZS Comp'.4 Core Components Please visit the Zep Solar web site at www.ze,solar.com for further resources, including installation videos, fut[-length installation guides. the Zepulator" online design tool. component- level installation videos, Engineering Certificaton Letters with Span Tables and training ctasses 6 Zep Tool For technical support questions, or to schedule a training class, please contact Zep Solar Support Comp Mount. Type C Interlock Copyright Notice #30 Ton Bit © 2013 Zep Solar, Inc. Zep Solar reserves the right to make specifications changes without prior notice. All rights reserved. Leveling Foot Grip End Caps PAGE 8 ul Molill,00 Jun,Il 10 13515 RM Documint Nn 800·4 51·COI Re, A .ww./pmo"reorn PAGEI ,·c» 34 . ZS Comp Quick St,rt k-12- - ZSCempOIck 5tarl 11 Ground ZeD 2 Layout Remaining Rows Module dimeision \ ... \ + 1/2" 15 6 Span Table 4 lookup Roof Attachments Ground the Array 8 AWG 45 inch-lbs 14-10 AWG 40 inch-[bs 6 AWG 50 inch-tbs 1. / r77 3€ ....epsolar.com L.Mt WH June Il, 2185.15 PM Doturnmn:Ne 000445&301 Re, A ......p-/r=I PAGE 7 ims,wint, dwoo SZ -- :30¥d 25 Comp Oulck 6*1 12 8b Manage Wires 4 Align First Row -r The DC Wire Clip hotds wires In two orientations. 5 Arn 1.25" Level alt Feet to string line 8c Secure Leveling Feet ..0. 3y Sk:-1 Complete first module row. Rotate onto Leveling Feet a Use Zep Align with center mark Tool Lr m . Irl -1 1 *- i 1 Connect Skin sections0 l 1 1.25-e . ....ap•6=tom Lait ModlflJun,1120135·1504 Documm: No 800-1451-001 Rev A wiw.ze/501*Dom nAOCI zicomp Quick St,rt 1¥d ZS Comp 0/lk Start 13 Level rnDLI Grip The Grip secures the Array Skirt to the Leveling Feet 8 First Row m-At;qn . I . En .,9- -UT gap Lower Drop in second module One Grip for each front-row I-* Leveling Foot V 4- 7 - .'0 Kickstand ---i First Module 8a Interlock Modules a Atign Use Zep Tool El kl,gn t . L e e Kickstan Interlock in closed position Swivel Slide ----- -- --- ..../plolar.om I.•stl'loditied Jui,ell 20135,15PM Dac. ment N, 500·1451·001 Re, A -va¥.le'll ./.com PAGE 5 CD 0.3 0 \41 3 1 0-1 W ZS Comp Oulok Stert ZGCorn, 0,1011 St-t 14