RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
sol-01 cBc 2013
Solar Photovoltaic (PV) Checklist for Detached STNGLE FAMTLY RESIDENCES Onty
lnstructlons: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certiflcation section below. A copy of this form shall be attached to each oi TWO sets of plans, of
minimum 11" x 17" size NO estion lan check shall be re
Project Address:1606 HURON, SANTA ANA, CA 92706
SOUTHWEST SUN SOLAR, INC
contractorLiconseNumber: 1004667
2
3
6
7
YES NO
m tr
8 Etr
AE
Etr
Etr
tstr
Etr
Ettr
atr
I
I cerlify under penalty of pe{ury under the laws of the State of California t the aqove is true:
print Name: MlMl NGO Signature:
phone Number: 714 582 3909
Ema it Address: PERMIT@SOUTHWESTSUNSOLAR.COM
/t
-)c
*-SNTA
ANA-"ffi
Are the following applicable to the proposed project?
Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the Califomia Fire Code, and is this shown on the roof plan?
Will the PV system be installed on a roof having only one roofing layer with no
overlays?
Will the PV array be flush mounted to the existing roof so that the plane of lhe
modules (panels) are parallel to lhe plane of the roof?
Will the PV system weigh maximum 4 pounds per square feel or less?
Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
Will the PV system be installed with a space of 2" minimum to 10" maximum between
the underside of modules and the surface of the roof?
Will the PV system be installed without using any ballast system or counter-weighl
system?
Will the anchors be installed with a maximum horizonlal anchor spacing of 6 feet
and is this maximum horizonlal spacing shown on the plans?
Will the minimum 5/16" lag screws bs installed with a minimum 012-112inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
Are ALL the structural pages ofthe plans WET stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacture/s PV support information.)
Date:
Contractor Company Name:
4.
5.
lO.EE
Re\:811712015