HomeMy WebLinkAbout10181130_120 S. HARBOR #H - PlanPlanning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19)ELECTRICAL SIGN Santa Ana, CA 92702 (714) 647-5800 REQUIREMENTS www.santa-ana.org Code references are to the 2010 California Electrical Code (CEC) All signs require Planning Department approval. All electrical signs require electric plancheck and permit. 1. Manufacturer's instructions are required at the time of submittal C-11: 3-21-2011 2. Submit detailed installation instructions including diagrams to the Building Department for plan review at the time of submittal. Plans must include appropriate items noted by this bulletin. 3. Cash or surety bond in the amount of $200.00 is required at time of issuance for each address. The cash or surety bond will be refunded after all required finals. A building permit is also required - except for open or highlight neon lighting. Installation Requirements: CONTACT FIELD INSPECTOR PRIOR TO SIGN INSTALLATION. (SEE SECTION G OF THIS BULLETIN) 1. Conductors and equipment shall comply with California Electric Code Article 600. 2. All metal parts of a sign shall be bonded in the manner specified in Article 250. Isolated metal parts are permitted to be bonded by using an external green insulated conductor. Equipment grounding & bonding conductors must be sized by 110.26 and protected from physical damage. Minimum size is 14 AWG. CEC 600.7 3. A listed disconnect switch in the power supply primary, shall be installed within sight of sign or have permanently installed means for locking in an "OFF" position. This is also true for a transformer enclosure. CEC 600.6 4. A listed receptacle or an approved termination device shall be used for each neon electrode. To relieve stress at terminations, tubing shall be supported with listed tube supports in an approved manner within six inches of electrode connection. CEC 600.41 & 600.42 5. Every electric sign of any type shall be listed by an approved testing laboratory and shall be installed in conformance with this listing. That includes "1 of x", "2 of x" labeling for each separate unit of a multi-unit sign. CEC 600.3 6. All "can" letters and transformers housings shall have section labels that are readily visible after installation. CEC 600.4 7. Transformers shall be located where accessible and be securely fastened in place. Page 1 of 2 When not inside the sign, they need a 3 foot high x 3 foot wide x 3 foot deep workspace. Transformers are permitted to be located in attics or canopies provided there is a passageway at least 3 feet high x 2 feet wide with a minimum 12 inch catwalldwalkway from the point of entry. Transformers must be securely fastened and independent of T- bar when above a suspended ceiling. No part of sign may be fed with flexible cord when located above T-bar ceilings. CEC 600.21(E&F) & 400.8 8. Adequate illumination shall be provided for all working spaces about electrical equipment. This applies to attics and canopies when entry is required to service or inspect the equipment. At least one switch is required at entrance. CEC 110.34 & 600.21 9. Doorway to an attic or canopy space shall be minimum 3 feet by 2 feet wide. CEC 600.21(E) E. Open neon outline or highlight lighting. 1. To be treated as a sign by this department. However, Section D-5 & D-6 of this bulletin will not apply. 2. Neon,tubing shall be located where not normally exposed to physical damage. Open neon tubing below 9 feet shall be protected from physical damage by an approved shielding method. CEC 600.30 and 1 10.34(E) F. Light-Emitting Diode (LED) Signs 1. Will be treated as a sign by this department. All sign rules in sections A, B, C, D, F, and G will apply as appropriate. 2. LED illumination for signage must be a listed or recognized component. Many LED manufacturers specify particular brands and models of transformers some do not. Manufacturer information to clarify this issue is required on LED sign plans. 3. Unlisted LEDs may not be used in an electrical sign or as permanently installed illumination. 110.3 4. Please have packaging or catalog cut-sheets on hand for inspector to review when LED modules do not bear listing symbols. G. Inspections 1. Contact an Electrical Inspector one (1) workday (minimum) in advance of installation to arrange a site meeting on dav of installation. 2. Call for inspection Monday through Friday, 8:00- 8:30 a.m. at (714) 647-5821. Approved prints and the job card must be on site for inspection. Page 2 of 2 . October 1, 2013 SIGN COMPONENTS MANUAL (SAM) 90 6. The suitability of the diffuser to serve as a barrier or endosure shall be determined in the end use product. Consideration for addressing electrical, flammability, and mechanical properties shall be given. LOUISVILLE LAMP CO 3316 GILMORE INDUSTRIAL BLVD E352989 LOUISVILLE, KY 40213 Class 2 LED light board, Models LB-3624A, LB-3624B, LB-3624C. 1. These products are only suitable for connedion to a Class 2 power source rated 12 Volt DC or less. 2. These products has not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited circuit and which is rated greater than 12V DC. 3. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. When these products are used in applications other than signs the need to conduct a temperature test shall be considered. 7. These products cannot be wired in series. LUCKY VALLEY TECHNOLOGY (SHENZHEN) CO LTD NORTHERN DIST OF SCIENCE & TECH PARK 3 QIONG YU RD, 1 WORKSHOP, 6RT NAN SHAN DISTRICT E347782 SHENZHEN, GUANGDONG 518000 CHINA Class 2 Output LED Driver, Model RG180-W3V012SD0. 1. The output (Red/Black) of each unit complies with Class 2 criteria of UL 1310. 2. The device is provided with 18 AWG input and output leads. The suitability of input and output connections shall be determined in end-use application. 3. The suitability of grounding means shall be determined by end product. 4. The device is not intended for field wiring used. 5. The device is intended to be connected to a maximum 20 A branch circuit. 6. The devices are of the constant current type that requires the proper number of LED modules and controllers that does not exceed the maximum output voltage/current. 7. The measured maximum external enclosure temperature (Tc) is 77.2 degree C when the room ambient temperature are 60 degree C. The suitability shall be determined in end application. 8. The devices employ input surge suppression protection, Cat. No. S14K385E2K1 under UL File E321126, which is intended end-use SPD type 2. The suppressed voltage rating is 385 Vac. The suitability of use of this component shall be determined in the end-product application. 9. No mechanical test has been conducted for the models and the metal chassis is considered as dead metal. The devices shall be mounted in the intended manner in an enclosure, having adequate strength and thickness with acceptable spacing being provided. 10. The device has been evaluated for dry and damp locations use only. 11. In the end product, LED driver spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 12. In the end product, LED Drivers shall be located not less than 1 inch (25.4mm) apart when arranged end-to-end, and not less than 4 inches (102mm) apart when arranged otherwise. PLUCKYSTAR ELECTRONIC TECHNOLOGY CO LTD 10 FUSHENG RD HECHENG ST GAOMING DISTRICT E320022 FOSHAN, GUANGDONG 528500 CHINA LED Modules, Models LS0723x, LS0766x, LS0769x, LS0776x, LS0782x, LS0783x, and LS-KM02-x where that x may be R, G, B, Y, CW, VWV, P or O indicating LED Color. 1. These products are only suitable for connection to the output of a UL Listed or R/C Class 2 Power Supply rated 12VDC. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 requirements. 3. These products are rated per the Table on Page 2. When units are connected to a Class 2 circuit, their number is to be limited to draw a total wattage of no greater than the secondary current rating of each Class 2 power supply. 4. These products are suitable for use in dry, damp and wet locations without additional enclosures. LED Modules, Models LS0766HD, LS0791 R and LS0791 H. 1. These products are only suitable for connection to the output of a Class 2 power source. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 requirements. 3. The LED modules are rated as noted in the electrical ratings table. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations with supply sources rated at electrical ratings or less. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. These products may be secured in place in the end products by any means available. Class 2 LED modules, designated as LSXXXX-YY series, where XXXX and YY may be combinations of any numbers. 1. These products are only suitable for connection to a Class 2 power source rated 24 Volt DC or less. 2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy limited circuits. 91 SIGN COMPONENTS MANUAL (SAM)October 1, 2013 3. When these units are connected to a Class 2 supply circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. These products may be secured in place in the end product by any means available. LED Modules, Models LS-0767, LS-MZ0609, LS-MZ0612-2 and LS-MZ0612-3. 1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less. 2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy limited circuits. 3. When these units are connected to a Class 2 supply circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations. 5. These products are not required to be endosed or protected from the weather in the end product. 6. These products may be secured in place in the end product by any means available. LUMIFICIENT CORP E230262 8752 MONTICELLO LN NORTH MAPLE GROVE, MN 55369 Class 2 LED Modules, HRL-06-PFC-96, HRL-08-PFC-96-BMA, HRL-xx-PFC-96yy, where xx denotes 06 original model or 07 Alternate constructions, where yy denotes BM for the use of the CBI circuit breaker Model No. (BFQ1 PA-B07XC-0500X), Class 2 Power Unit. Model HYPERION R-Lite System-LED tape. Model HLR-PC power connector. Model HRL-IDC Power IDC connector. 1. The power.units were submitted and tested for a maximum manufacturer's recommended ambient (Tmra) of 40(C. 2. The HRL-06-PFC-96 power unit is provided with a conduit fitting suitable for 1/2 in. Trade Size rigid nonmetallic conduit. 3. The HRL-06-PFC-96 power unit, HRL-=-PFC-96yy and HRL-08-PFC-96BMA, HYPERION R-Lite System-LED tape, HLR-PC power connector, and HRL-IDC Power IDC connector are suitable for dry or damp locations 4. Temperature test at 40(C, Inputs and Dielectric test was conducted. The need for additional test shall be determined in the end used product. 5. The Model HRL-08-PFC-96BMA power unit is provided with a 1/2 in. Trade Size conduit opening. Class 2 LED modules Model HYPERION R-Lite System-LED tape, Model HLR-PC power connector, & Model HRL-IDC Power IDC connector. 1. The power units were submitted and tested for a maximum manufacturers recommended ambient (Tmra) of 40°C. 2. The HRI--06-PFC-96 power unit is provided with a conduit fitting suitable for 1/2 in. Trade Size rigid nonmetallic conduit. 3. The HRI--06-PFC-96 power unit, HRL-xx-PFC-96yy and HRI--08-PFC-96BMA, HYPERION R-Lite System-LED tape, HLR-PC- 200 power connector, HRL-JC-200 jumper connector and HRL-IDC-B Power IDC connector are suitable for dry or damp locations 4. Temperature test at 40°C, Inputs and Dielectric test was conducted. The need for additional test shall be determined in the end used product. 5. The Model HRL-08-PFC-96BMA power unit is provided with a 1/2 in. Trade Size conduit opening. LED Driver; Cat. No. Model HRL-06-PFC-24, HRL-xx-PFC-24yy where xx denotes 06 original model or 07 Alternate constructions, where yy denotes BM for the use of the CBI circuit breaker Model No. (BFQ1 PA-BO/XC-0500)<), Class 2 Power Unit. 1. The HRL-06-PFC-24 power unit was submitted and tested for a maximum manufacturer's recommended ambient (Tmra) of 40(C. 2. The HRL-06-PFC-24 power unit is intended for installation inside an electrical enclosure. Minimum spacing between adjacent power units is 4 in. 3. The HRL-06-PFC-24 power unit is suitable for dry or damp locations. Class 2 LED module, designated as Hyperion R2, Cat. No. HR2-XXXX, where XXXX may be replaced with any alphanumeric characters. 1. These products are only suitable for connection to a LPS or Class 2 power source rated 24 Volt AC or less. 2. These products are each rated max. 2.4 watts per module. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 3. These products are suitable for use in dry and damp locations with supply sources rated at 24 Volts AC or less. 4. These products may be secured in place in the end product by any means available. Class 2 LED Modules, designated as H-Lite-XXXX series, E-Lite-XXXX series, E-Lite-YYY series, where XXXX may be any numeric characters and YYY may be any alpha characters. 1.These products are only suitable for connection to a Class 2 power source rated 8 Volts AC or DC or less. 2. When units are connected to a Class 2 circuit, these products are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp or wet locations. 5. These products may be secured in place in the end product by any means available. Sign Accessories, Transformer, Class 2 Inherently limited, Model HRL-PSLP-13 and Transformers Class 2 Non-Inherently limited Models HRL-PS277-70, HRL-PS96-70, and HRL-PSSQ-25-T. 1. These LED Transformers have been evaluated to Class 2 output requirements for AC circuits with a maximum of two Class 2 output. 2. These products are provided with the following electrical ratings: Max. Input Model Input Volt HZ Amps Watts V(ac)Current A VA/Output #of Output HRL-PSLP-13 120 50/60 0.175 21 8.3 2.0 17 (1) HRL-PS277-70 277 50/60 0.347 94 8.5 5.0 42.5 (2) LED MODULE SERIES ITEM NO.:LS0783 LS0783H-3 SIZ 53.8mm • All the:size date above is in mm • Tolerance.for thesize date is *0.2mm APPLICATION: • ·Applicable for home, shopping mall, office meetihg room, hotel, cabinat,,and s.how windows, etc. E: r 51 15.8mm 17 7:4mn Sheet,No.:01 CRJ.o: E320022 LS0783H-4 . FEATURE: • NoUV or IR radiation. O; Su*er thin and flexibla • Waterproof IP65 • High Brightness SMD LED •, LED QTY: LS0783H-3: 3PCS L50783H=4:4PCS • 50000 hours long life span 9 Color Temperatore CW: 8000-9000K DW: 6000-6500K WW: 3000-330OK * lowtemperatorerising, less-than 20°C . Less than 7%.light decay ih 6,000 houfs testing . 120° Beaming Angle • Colour: LS0783H-3: G/B/P/WW/DW/CW LS0783H-'4: R/Y Absolute Maximum Rating at TA=25t Parameter :: ·Symbol Absolute Maximum Rating; .,·Unit Voltage Vilv DC12V VAC Elettrostatic Discharge ESD 2000 V Operating Temperature TOPR -20°C-45°C °C Storage Temperature TSTG -20°C-60°C °C Sheet No. : 02 Electrical/Optical Characteristics at TA=25t(VIN=DC12VAC, 50Hz) Colour Voltage Current Power CT/WL 3Luminous Ra WW DC12V 20mA 0.6W 3000-3300K ------ 64 Maximum Connection 100Pcs CW DC12V 20mA 0.6W 8000-9000K ------ 83 100Pcs R DC12V 20mA 0.6W 620-630nm ------ ------100Pcs G DC12V 20mA 0.6W 520-525nm ------ ------100Pcs P DC12V 20mA 0.6W 380-760nm ------ ------100Pcs Y DC12V 20mA 0.6W 585-595nm ------ ------100Pcs illuminated diagram 00 60°60° 90° 90'10016 BON 40%20,6 096 201· 4096 6096 80%100% INSTALLATION i 60% 1.Please rip PE adhesivetape on the back of the product, fhen stickto the obiects where you Want. 2.Use the screws to fasten it again. MAX 100PCS PowerDCUV ===== 3.Connectmultipleproduct (max 100 pcs), (The tatal powerconsumption of products should be lessthan 80% of driver's power),the connect the driver. • Connect red wire to the positive poiarity and blackwire to the negative polarity of power supply • Operate on 12 Volt DC Power Supply(constant voltage) • Wire length of powersupply should be no more than 3 meters;if more than that,suggest increasing wire diameter Sheet No. : 03 NOTE • Low voltage product, please make sure of the DC12v =t 2V input voltage • Please doh't press the elements on the PCB from any angle by stress • Non-bendable • Please don't install in flammable, explosive orcorrosive circumstances -·flaL-Ud__ 4\ t./4 9:4 .... /91 9. /7 17:I' rr,AFFMUVEW PLANNEG DIVISION MASTER I.D. 7-6 ill - Ill IKE 4 .. 0 ec Zooe 69 -L 'LANNER AL \ P DATE 4- 13 14 *RANSFERRED BY DATE PLANNING INSPECTION REQUIRED: ROUGH FINAL NONE>< MAME (714) - RETAIN P: ANS FOR /: i CURE REVISIONS.:UUBJEC-™' 93 {TE?bis :.».ECKED AND CONDiTIONS BELOV,/ 0 1%[3 7·.·(% > . ...3. D .'... ..·---·ONS/MODIFICATIONS u AL.t. f,·,:.h'.:.· 5 2.1 .'. ATCH EXISTING O SCRE.1 4 ' ,:1.26'...9 :.O O Subivill- 1-/c.'··08<CACT PLANS re,in,TIONC· 664 - 2014 -3 1 1 i/la-) 01 H -8 7-8 19 -»099/0-}t - °S 0-21 ploold 10 t.4 ,, 0/ Discount - r Li 1 1 t -=- ·-·21:- -TE--r .l Ir,1 , 1- r I'L 7 _T-· i 9•8#IlitTIN* 14861 Moran St. #B Westmister, CA 92683 (714)848-9616 Phone (714)740-5030 Fax Website:www.i2isigns.com Email: info@i2isigns.com COMMENTS: [il 1 L ' ....Pet*>90*«ehe . + :4·11'f¢#EW'922156: '2341*5 492% .3 .a„.yay.=;.4 N.nmit»Ze.·: · .----0-·..6/Ga-€92:2 . 911, e':, I- U 0 ...... .. '6 J·Juk·04-,··4-,3«hi'+'3*44"34 ...4 -F A I· 1 · U·r ' . - Tr#.%*4..116,,.-9T:.='ittebr 3.944*UAL>3-**#24=,»it..40.c.46?i·ew 'ft'*p'17:·r'417«f-·fr-**19&52 A .8.-2 =20=fi-&22*12113,1 .,4.*7.9€•'.3.,·21 ...4.2 Irr.·•. *21'.2,0-·,·P·-p Q'.tiu ,·. ·.7.>..:, -42,1;ZqU·;:,eAIJI V . · .... · ·L--2/ h.» j 2 ..44 -44-:ket tor:. 43 155.1 ,IMV//<1 *MM:9«6342,'d f '1 '''LE. - ..,A· 0, r· .,· /·.·Ara€,k·:P**r¥ /. ,.*a,i·,·.pot,8 -1. 1 1 0 18/3.4..01234...17.P:J'a '1 U Mi' 0 1 MABJaL, . '11 1 ' .t- - .....Z. 1'*.re 416 ...., SCALE: 1/8"=1' /,U-b• ··'ad../'. CLIENT:Hong Phat Restaurant ADDRESS 120 S. Harbor Blvd. Suite H Santa Ana LOCATION:Width 25' DATE:04/15/14 CONCEPT: A1234 SALES: RR DRAWNBY: RR CUSTOMER APPROVAL LANOLORD APPROVAL SIGNATURE DATE SIGNATURE DATE WE HAVE REVIEWED AND APPROVEDTHE SIGN DETAILED HEREINTO BE FABRICATED PER THE SPECIFICATtONS SHOWN ON THE DRAWING This sign is intended to be instamed In accordance with I the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. Contractors Lic. #917099 NOTE: This is an original drawing, created by i2i Signs Corp. It is submitted for your personal use in connection with a project being planned - for you by ili Signs. It is not PAGE to be show to anyone outside 1 your organization, nor is it to be used, reproduced, copied orOF exhibited in any fashion. Any 2 printed colors on drawing are approximate. 54'. -i#* /41/.64:4#...54: 20' Mt((Mnify*.4823?5¤Si,jE2475314%9 , .I L-L_--2__.7 -I ./ I 22* -/T,111:7.711.1 3.5 11: I ..I- I PRIN) -14861 Moran St. #B Westmister, CA 92683 EN,0Zi*REN"ge/M""Mag'MEW/liPE¥6)3¢'r-J ;* 4%:SK#+4*1*4 ..(714)848-9616 Phone (714)740-5030 Fax*444..4- 04' 44 Website:www.ilisigns.corn ;,53 MY.Pe.*bir#/4'. - 1 1 Email: info@i2isigns.com .mi,mE; 3.43 , 1 '.... COMMENTS: 9/ -1 1. MANUFACTURE·AND INSTALL (1) SET OF Il.UMINATED CHANNEL LETTERS & (1) SET OF 2" FOAM LETERING - 2. FACES:i € t/10' - - -i L r; 1 -COLOR"Hong Phat"20" H TO BE 1/8 RED ACRYLIC - "ASIAN NOODLES & BOBAS" 2" FOAM ACRYLI€ FACE RED , 1. I. , 3. RETURN:13>ruu)¢) .I , I ... :.7 .4 r- .-5"pEEP PAINTEDBLACK TRIMP CAP Bl:ACK Gdd .1 , . . I .: . ..,1- 1- I .- -. ", 1 4. ILLUMINATION: RED, 12 vdc LED LIGHT UNITS - SPACING: 2.5 UNIT 5. L ETTERS SHALL BE MOUNTED DIRECTLY ON 6X25 STUCCO WALL WITH NON-FERROus FASTENERS 1/4"x 1-1/2"PER LETTER (4) MIN.S/STROKE INCH 6. ALL WIRING AND COMPONENTS TO BE UL APPROVED. 7. TRANSFORMER TO BE UL LISTED 12 - 500 WATT AS NEEDED - DISC1*01-- -GL_ ..r --<8. UL LISTED 18AW G WIRE .1 ,§,WITCH 9. 6X25 STUCCO 10.ALL FASTERERS TO BE NON-FERROUS STAINLESS STEEL SCALE: 1/8'91' t. 44 8. 33-/31.pill-NOTE: This is an orjginal 5"DEPTH drawing, created)y)2i Signs Corp. It is sub*tt#el for yourWater drain hole - personal use in cAnectionI®R12:gigtjMI;4ing planned nus sign Stint*Rded to be -1 CUSTOMER APPROVAL WINI]LORD APPROVAL instatled in T;Rce with *Ayou by ili Signs. It is nbtCUENTHong Phat Restaurant the requIre*ts,of Article PAGE 4,be show to anyone outside600 ofthdNIDInal EIectrical ADDRESS 120 S. Harbor Blvd. Suite H Santa Ana '>7 .4- c..01:Wdr,0-/icable 2 j your organization, noris it to-4,; ,J j .lod,026,1Zs. This iNce.. #I * be used, reproduced, copied or LOCATION:Width 25' . SIGNATURE DATE SIGNATURE DATE $;oper grounding and --OF bonding of the sign. . -exhibited in any fashion. Any Contractors Lic.2 printed colors on drawing areWE HAVE REVIEWED AND APPROVED THE SIGN DETAILED HEREIN TO BE DATE:04/15/14 CONCEPT:A 1 234 SALES: RR DRAWN BY: RR FABRICATED PER THE SPECIFICATIONS SHOWN ON THE DRAWING #917099 approximate. 'r'K, 9 -22-1 4 \20 S \--1Clobor- 4¥¥\- City of Santa Ana, CBC & CEC 2013 Minimum (4) screws per letter,A local disconnect for the monument sign(s) is maximum 24" on center, 2"required or the dedicated circuit breaker(s) musl penetration, #10 sheet metal screws, & jbe jndividually lockable in the off position.¢2) W" drain holes per letter C 600-6;cess to any power supply in attic or aboveceiling shall be immediately from a ladder or -with a2x3 foot access door & passage with a-inch walkway. CEC 600-21 (d)(d)12City of Santa Ana Planning & Building Agency - ¥ PERMIT TYPE:-81-ELEC% PLBGELECTRICAL PLAN APPROVAL H GRADING PERMJT#10 1,Fl 13 This 802 01 plans and specificalons must be kept onthe job at all times and It Is'unlawful to make any OCC. GROUP 3 -38 (702 changes or atterations on same without written per-I mission from the Department of Building Safety CONSTR. TYPE City of Santa CODE EDITIO 201?.The approval of this plan and spectfications SHALL NOT44#Id to permit nor be an approval of tho I FLOOD ZONS= - violatio„ or any provisions of ANY City Ordinance or SWNJ#j.1-Al -FLOOD ZONE CERTIF. REQ'D YES -Appr*bk)(JinSCE[3'm)1 C 4:rry oF SANTAANA MICROFILM YES Alt), | DEPARTMENT OF BUILDING SAFETY i RADIANT BARRIER @ ROOF YES 4 ' RESIDENTIAL DEV. FEE YES No SCHOOL DISTRICT YES ABI M 0