Loading...
HomeMy WebLinkAbout1801 E Dyer Rd - REV 1 - PlanDESCRIPTION ABV.ABOVE A.C.T.ACOUSTICAL CEILING TILE A.D.A.AMERICANS WITH DISABILITIES ACT ADD'L ADDITIONAL A.F.F.ABOVE FINISH FLOOR A.S.T.M.AMERICAN SOCIETY FOR TESTING AND MATERIALS BD.BOARD BM.BEAM B.O.BOTTOM OF C.J.CONTROL JOINT C.L.CENTERLINE CLG.CEILING CLR.CLEAR C.M.U.CONCRETE MASONRY UNIT C.O.CLEANOUT COL.COLUMN CONC.CONCRETE C.W.COLD WATER DEMO DEMOLISH OR DEMOLITION DIA.DIAMETER DIM.DIMENSION DS.DOWNSPOUT DN.DOWN DWG.DRAWING DESCRIPTION EA.EACH E.I.F.S.EXTERIOR FINISH AND INSULATION SYSTEM E.J.EXPANSION JOINT ELEV.ELEVATION EQ.EQUAL EXT.EXTERIOR F.D.FLOOR DRAIN OR FIRE DAMPER OR FIRE DEPARTMENT F.E.FIRE EXTINGUISHER F.F.FINISH FLOOR FIN.FINISH FIXT.FIXTURE FLR.FLOOR F.O.FINISH OPENING F.R.T.FIRE RETARDANT TREATED FT.FEET GA.GAUGE G.C.GENERAL CONTRACTOR GYP.GYPSUM HB.HOSE BIB HDW.HARDWARE H.M.HOLLOW METAL HT.HEIGHT HTR.HEATER DESCRIPTION H.W.HOT WATER I.B.C.INTERNATIONAL BUILDING CODE I.D.INSIDE DIAMETER IN.INCH INFO INFORMATION INSUL.INSULATION INT.INTERIOR kV KILOVOLT kVA KILOVOLT-AMPS kW KILOWATT kWH KILOWATT-HOUR LL.LANDLORD MAX.MAXIMUM M.D.F.MEDIUM DENSITY FIBERBOARD MIN.MINIMUM M.O.MASONRY OPENING MTL.METAL N/A NOT APPLICABLE NEC.NATIONAL ELECTRICAL CODE NFPA.NATIONAL FIRE PROTECTION ASSOCIATION N.I.C.NOT IN CONTRACT NOM.NOMINAL N.T.S.NOT TO SCALE O.C.ON CENTER DESCRIPTION O.D.OUTSIDE DIAMETER OPP.OPPOSITE PLBG.PLUMBING PLY.PLYWOOD PNL.PANEL PNT.PAINT PR PAIR P.S.I.POUNDS PER SQUARE INCH P.S.F.POUNDS PER SQUARE FOOT PT.POINT P.V.C.POLY VINYL CHLORIDE r.RADIUS R.C.P.REFLECTED CEILING PLAN RD ROUND R.O.ROUGH OPENING REINF.REINFORCED OR REINFORCING REQ'D REQUIRED REV.REVISION RGH.ROUGH R.T.U.ROOF TOP UNIT R.W.L.RAIN WATER LEADER S.F.SQUARE FEET SIM.SIMILAR SPEC.SPECIFIED OR SPECIFICATION S.Q.SQUARE DESCRIPTION S.S.STAINLESS STEEL STC.SOUND TRANSMISSION COEFFICIENT STD.STANDARD STL.STEEL STRUCT.STRUCTURE SUSP.SUSPENDED T&G TONGUE AND GROOVE TA TO ABOVE T.B.D.TO BE DETERMINED TEMP.TEMPORARY T.O.TOP OF TPO.THERMOPLASTIC POLYOLEFIN TYP.TYPICAL U.L.UNDERWRITER'S LABORATORY U.N.O.UNLESS NOTED OTHERWISE U/S UNDERSIDE V.I.F.VERIFY IN FIELD V.C.T.VINYL COMPOSITION TILE W/WITH W/O WITHOUT WD.WOOD W.H.WATER HEATER W.P.WEATHER PROOF GENERAL PE R M I T S E T 08 / 0 1 / 2 0 2 4 RE V I S I O N 1 12 / 1 2 / 2 0 2 4 RE V I S I O N 1 (R E - I S S U E ) 01 / 1 0 / 2 0 2 5 RE V I S I O N 2 01 / 2 9 / 2 0 2 5 RE V I S I O N 3 02 / 1 4 / 2 0 2 5 RE V I S I O N 4 06 / 0 4 / 2 0 2 5 RE V I S I O N 5 07 / 2 3 / 2 0 2 5 G000 COVER SHEET G002 ACCESSIBILITY NOTES CIVIL C-1 OF 3 COVER SHEET C-2 OF 3 WATER PLAN C-3 OF 3 DETAILS ARCHITECTURAL A000 CPU CANOPY PLANS & ELEVATIONS A001 CPU CANOPY WALL SECTIONS A002 ADA KEY PLAN A002.1 OVERALL KEY PLAN A003 ENLARGED DEMO PLAN A004 ENLARGED FLOOR PLAN A005 INTERIOR ELEVATIONS & DETAILS STRUCTURAL S001 GENERAL STRUCTURAL NOTES S002 SPECIAL INSPECTION TABLES S100 CANOPY PLANS S200 SECTIONS & DETAILS PLUMBING P101 PLUMBING PLAN AND SCHEDULE FIRE PROTECTION FP100 NEW FIRE SPRINKLER PLAN, NOTES, AND DETAILS TENANT FLOOR & DECOR 2500 WINDY RIDGE PARKWAY, SE ATLANTA, GEORGIA 30339 CONTACT: KEVIN LITTLE EMAIL: KEVIN.LITTLE@FLOORANDDECOR.COM PHONE: (770) 359-8452 ARCHITECT ARCHITECTURAL DESIGN GUILD 2710 SUTTON BOULEVARD ST. LOUIS, MISSOURI 63143 CONTACT: SAM ESTES EMAIL: SESTES@ADG-STL.COM PHONE: (314) 644-1234 MECHANICAL, PLUMBING & ELECTRICAL ENGINEER ARCHITECTURAL DESIGN GUILD 2710 SUTTON BOULEVARD ST. LOUIS, MISSOURI 63143 CONTACT: JACK BRUNS EMAIL: JBRUNS@ADG-STL.COM PHONE: (314) 644-1234 FIRE PROTECTION CODE CONSULTANTS INC. 2043 WOODLAND PARKWAY, SUITE 300 ST. LOUIS, MO 63146 CONTACT: DENNIS KROCKER EMAIL: dennisk@codeconsultants.com PHONE: (314) 991-2633 REMOVED FROM SET FIRST ISSUE / REISSUED WITH REVISIONS REISSUED WITHOUT REVISIONS STORE #1291801 E DYER ROAD SANTA ANA, CA 92705 FLOOR & DECOR 1.THE BUILDING SHALL BE CONSTRUCTED IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES, LAWS AND REGULATIONS IN ORDER TO INSURE A FINAL CERTIFICATE OF OCCUPANCY FROM GOVERNING AUTHORITIES. 2.THE GENERAL CONTRACTOR AND ALL SUB-CONCTRACTORS SHALL FIELD VERIFY JOB SITE CONDITIONS PRIOR TO COMMENCEMENT OF ANY WORK AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH ANY WORK. 3.BIDDERS, BY BIDDING, CERTIFY THAT THE DRAWINGS AND THE SPECIFICATION BOOK HAVE BEEN REVIEWED AND THAT LABOR AND MATERIALS REQUIRED FOR A COMPLETE AND PROPER INSTALLATION ARE INCLUDED IN THEIR SUBMITTED BIDDING DOCUMENTS. 4.DURING THE COURSE OF CONSTRUCTION, IF THE CONTRACTOR UNCOVERS ANY CODE VIOLATIONS KNOWN TO THE CONTRACTOR OR ANY DISCREPANCY WITH THE DESIGN, THEY SHALL NOTIFY THE ARCHITECT AND FLOOR AND DECOR'S CONSTRUCTION PROJECT MANAGER IMMEDIATELY. 5.ALL MATERIALS INDICATED AS NEW SHALL BE PROVIDED BY CONTRACTOR UNLESS OTHERWISE NOTED. NO SUBSTITUTIONS ALLOWED. 6.CONTRACTOR SHALL ASSEMBLE AND INSTALL MATERIALS/PRODUCTS IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRIAL/ASSOCIATION STANDARDS. 7.THE CONTRACTOR IS RESPONSIBLE FOR ALL TRADE PERMITS REQUIRED TO COMPLETE THE WORK. 8.IF THE CONTRACTOR DISCOVERS, AT ANY TIME DURING DEMOLITION, CONSTRUCTION AND/OR REMODELING OPERATIONS, EXISTING CONDITIONS THAT COULD INCLUDE THE PRESENCE OF MOLD AND/OR MILDEW, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER'S REPRESENTATIVE AND THE ARCHITECT. 9.DO NOT SCALE THE DRAWINGS. 10.ALL ITEMS CONTAINED WITHIN THESE DOCUMENTS ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 11.SEE GENERAL CONDITIONS FOR ADDITIONAL APPLICABLE NOTES AND REQUIREMENTS. FLOOR & DECOR INDEX PROJECT DIRECTORY VICINITY MAP GENERAL NOTES SITE PHOTO TYPICAL ABBREVIATIONS REPLACEMENT OF EXISTING LOADING DOCK CANOPY. RESTROOMS ON THE FIRST AND SECOND FLOOR ARE BEING REMODELED PER AHJ ACCESSIBILITY COMMENTS RECEIVED. SCOPE OF WORK STATEMENT LOADING DOCK KEY PLAN BUILDING 2022 CALIFORNIA EXISTING BUILDING CODE MECHANICAL 2022 CALIFORNIA MECHANICAL CODE PLUMBING 2022 CALIFORNIA PLUMBING CODE ELECTRICAL 2022 CALIFORNIA ELECTRICAL CODE ENERGY 2022 CALIFORNIA ENERGY CODE FIRE 2022 CALIFORNIA FIRE CODE ACCESSIBILITY 2022 CBC - CHAPTER 11B (ICC/ANSI A 117.1-2009) GREEN 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE CONSTRUCTION TYPE IIIB OCCUPANCY M - MERCHANTILE FULLY SPRINKLERED YES (EXISTING) GROSS BUILDING AREA 55,667 SQ. FT. (EXISTING) CANOPY AREA 586 SQ. FT. CODE ANALYSIS APPLICABLE CODES FUNCTION OF SPACE GROSS FLOOR AREA STOCK 3,755 SQ. FT. (EXISTING) SALES 48,862 SQ. FT. (EXISTING) BUSINESS 1,400 SQ. FT. (EXISTING) *GROSS FLOOR AREA IS MEASURED FROM THE INSIDE FACE OF EXTERIOR WALLS PER SECTION 202 AREA OF NORTH WALL (COL. LINE A) 316'-5" x 22'-2"= 8011sf WALL OPENING CALCULATION AREA OF OPENINGS IN (COL. LINE A) (4) @25sf, (1) @ 100 sf = 200sf TOTAL PERCENTAGE OF OPENINGS = 2.5% PERCENTAGE OF ALLOWABLE OPENING AREA = 10 TO LESS THAN 15 FEET SEPARATION/PROTECTED 45% > 2.5% MAXIMUM AREA OF EXTERIOR WALL OPENINGS 1.THE SPACE IS PROTECTED WITH AN AUTOMATIC FIRE PROTECTION SYSTEM CONFORMING TO NFPA 13. 2.THE GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND HYDRAULIC CALCULATIONS FOR REVIEW AND APPROVAL TO THE AUTHORITY HAVING JURISDICTION PRIOR TO ALTERING THE SYSTEM. G.C. TO SUBMIT SPRINKLER DRAWINGS TO THE FIRE SPRINKLER ENGINEER FOR REVIEW & APPROVAL PRIOR TO SUBMITTAL TO AHJ. 1.FIRE SPRINKLER SYSTEMS: FIRE PROTECTION CONTRACTOR IS TO PROVIDE ENGINEERED DOCUMENTS FOR THE DESIGN OF THE FIRE PROTECTION SYSTEM MODIFICATIONS PER STATE AND LOCAL CODES. CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING ANY APPLICABLE PERMITS. 2.FIRE ALARM SYSTEMS: FIRE ALARM CONTRACTOR IS TO PROVIDE ENGINEERED DOCUMENTS FOR THE DESIGN OF THE FIRE ALARM SYSTEM MODIFICATIONS PER STATE AND LOCAL CODES. CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING ANY APPLICABLE PERMITS. FIRE PROTECTION NOTES DEFERRED PERMIT SUBMITTALS 1801 EAST DYER RD. SANTA ANA, CA 92705 CONSULTANT PROJECT 2022.0315.00 54,016 SF OWNER PHONE:(404) 471-1634 129 08/01/2024 SA N T A A N A , C A L I F O R N I A 2023 Q2 ALL ARCHITECTURAL AND ENGINEERINGDRAWINGS ARE IN CONFIDENCE ANDDISSEMINATION MAY NOT BE MADE WITHOUTPRIOR WRITTEN CONSENT OF THE ARCHITECT.ALL COMMON LAW RIGHTS OF COPYRIGHT ANDOTHERWISE ARE HEREBY SPECIFICALLY RESERVED 2500 WINDY RIDGE PARKWAY, SE ATLANTA, GA 30339 ISSUE DRAWN: CHECKED: SHEET SEAL AREA : JOB NUMBER: ISSUE DATE: STORE NUMBER: ST O R E # 1 2 9 PROTOTYPE: CITY APPROVAL STAMP PERMIT SET 08/01/2024 LICENSE: #C-39437 EXP: 07/31/2025 1 REVISION 1 12/12/2024 1 REVISION 1 (RE-ISSUE)01/10/2025 2 REVISION 2 01/29/2025 3 REVISION 3 02/14/2025 4 REVISION 4 06/04/2025 5 REVISION 5 07/23/2025 COVER SHEET G000 GJS/RAB AJB 5 Revision to 101120910 (iss. on 3/11/25)Rev 1 #101125080 APPROVALS: BLDG - T. Le 3' - 4 " 2'-8" 1" 15 2'-0"24'-8" 0'-0" A.F.F. FINISH FLOOR 15'-0" A.F.F. B.O. CANOPY CAST-IN-PLACE CONCRETE COLUMN BASE, PAINT P-2 CONTINUOUS CAULK TO MATCH ADJACENT SURFACE - TYPICAL 8" HSS COLUMN, PAINT P-1 DOWNSPOUT ALONG SIDE OF COLUMN (AWAY FROM CENTER OF CANOPY; CONNECT TO GUTTER OUTLET; EXIT TO DAYLIGHT EXTERIOR SIDE OF CANOPY HSS BEAM, PAINT P-1 - SEE STRUCTURAL 18'-0" A.F.F. T.O. CANOPY TPO BASE FLASHING BIRD NETTING (BIRD NET 2000 OR EQUIVALENT, COLOR: BLACK) AT UNDERSIDE OF CANOPY ALUCOBOND AXCENT .040” ACM PANEL (COLOR TO MATCH P-3) OVER 3/4" EXTERIOR GRADE PLYWOOD METAL STUDS - SEE STRUCTURAL STEEL BEAM, PAINT P-1 - SEE STRUCTURAL 1/2" EXTERIOR GRADE PLYWOOD 60 MIL. TPO ROOF MEMBRANE OVER 1 1/2" RIGID INSULATION OVER METAL DECK 1 WALL SECTION AT CPU CANOPY SCALE: 3/4" = 1'-0" SHEAR PLATE , PAINT P-1- SEE STRUCTURAL ADHESIVE ANCHORS - SEE STRUCTURAL CAP PLATE , PAINT P-1 - SEE STRUCTURAL PLATE, PAINT P-1 - SEE STRUCTURAL METAL DECK - SEE STRUCTURAL STEEL ANGLE - SEE STRUCTURAL STEEL ANGLE - SEE STRUCTURAL 8" SLOPE TOP 1/4" PER FOOT AWAY FROM COLUMN 3 A001 4 A001 2 A001 CRICKET - TAPER INSULATION 1/4" PER FT. DOWN TOWARD DRAIN PRIMARY & SECONDARY ROOF DRAINS - SEE PLUMBING FIXTURE SCHEDULE ON A000 18'-0" A.F.F. T.O. CANOPY TAPERED PAC-TITE .040” ALUMINUM COPING - COLOR TO MATCH P-3 STEEL STUDS - SEE STRUCTURAL DRAWINGS ROOF MEMBRANE BASE FLASHING LAPPED OVER TOP BLOCKING AND SEALED AT ROOF DECK 60 MIL TPO ROOF MEMBRANE OVER 1 1/2" RIGID INSUL OVER METAL DECK SLOPE 3 5 / 8 " ALUCOBOND AXCENT .040” ACM PANEL - COLOR TO MATCH P-3 4 COPING DETAIL SCALE: 1-1/2" = 1'-0" 15'-0" A.F.F. B.O. CANOPY METAL STUDS, PAINT P-1 - SEE STRUCTURAL 2 EAVE DETAIL SCALE: 1-1/2" = 1'-0" 3 FLASHING DETAIL SCALE: 1-1/2" = 1'-0" TPO BASE FLASHING 60 MIL. TPO ROOF MEMBRANE OVER 1 1/2" RIGID INSULATION OVER METAL DECK ADHESIVE ANCHORS - SEE STRUCTURAL PLATE, PAINT P-1 - SEE STRUCTURAL STEEL ANGLE - SEE STRUCTURAL METAL DECK - SEE STRUCTURAL ROOF DRAIN - SEE PLUMBING FIXTURE SCHEDULE ON A000 ALUCOBOND AXCENT .040” ACM PANEL (COLOR TO MATCH P-3) OVER 3/4" EXTERIOR GRADE PLYWOOD STEEL ANGLE, PAINT P-1 - SEE STRUCTURAL 1801 EAST DYER RD. SANTA ANA, CA 92705 CONSULTANT PROJECT 2022.0315.00 54,016 SF OWNER PHONE:(404) 471-1634 129 08/01/2024 SA N T A A N A , C A L I F O R N I A 2023 Q2 ALL ARCHITECTURAL AND ENGINEERINGDRAWINGS ARE IN CONFIDENCE ANDDISSEMINATION MAY NOT BE MADE WITHOUTPRIOR WRITTEN CONSENT OF THE ARCHITECT.ALL COMMON LAW RIGHTS OF COPYRIGHT ANDOTHERWISE ARE HEREBY SPECIFICALLY RESERVED 2500 WINDY RIDGE PARKWAY, SE ATLANTA, GA 30339 ISSUE DRAWN: CHECKED: SHEET SEAL AREA : JOB NUMBER: ISSUE DATE: STORE NUMBER: ST O R E # 1 2 9 PROTOTYPE: CITY APPROVAL STAMP PERMIT SET 08/01/2024 LICENSE: #C-39437 EXP: 07/31/2025 1 REVISION 1 12/12/2024 1 REVISION 1 (RE-ISSUE)01/10/2025 2 REVISION 2 01/29/2025 3 REVISION 3 02/14/2025 4 REVISION 4 06/04/2025 5 REVISION 5 07/23/2025 CPU CANOPY WALL SECTIONS A001 HL/RAB AJB 5 5