HomeMy WebLinkAbout2224 N Concord St - REV 1 - PlanREVISIONS BY
DRAWN BY:
SCALE: AS NOTED
A1
1
Th
e
s
e
d
r
a
w
i
n
g
s
a
n
d
s
p
e
c
i
f
i
c
a
t
i
o
n
s
a
r
e
t
h
e
p
r
o
p
e
r
t
y
an
d
c
o
p
y
r
i
g
h
t
o
f
T
.
P
.
C
.
D
r
a
f
t
i
n
g
S
e
r
v
i
c
e
s
an
d
s
h
a
l
l
n
o
t
b
e
u
s
e
d
i
n
a
n
y
o
t
h
e
r
w
o
r
k
e
x
c
e
p
t
by
a
g
r
e
e
m
e
n
t
w
i
t
h
T
.
P
.
C
.
D
r
a
f
t
i
n
g
S
e
r
v
i
c
e
s
Wr
i
t
t
e
n
d
i
m
e
n
s
i
o
n
s
s
h
a
l
l
t
a
k
e
p
r
e
c
e
d
e
n
c
e
o
v
e
r
sc
a
l
e
d
d
i
m
e
n
s
i
o
n
s
a
n
d
s
h
a
l
l
b
e
v
e
r
i
f
i
e
d
a
t
t
h
e
jo
b
s
i
t
e
.
A
n
y
d
i
s
c
r
e
p
a
n
c
i
e
s
s
h
a
l
l
b
e
b
r
o
u
g
h
t
to
t
h
e
a
t
t
e
n
t
i
o
n
o
f
T
h
e
o
d
o
r
e
C
r
i
s
t
e
s
c
u
pr
i
o
r
t
o
s
t
a
r
t
w
o
r
k
.
SHEET 1
OF 1 SHEETS
T.
P
.
C
.
D
R
A
F
T
I
N
G
S
E
R
V
I
C
E
S
14
4
0
1
S
y
l
v
a
n
S
t
.
#
2
0
9
,
V
a
n
N
u
y
s
,
C
A
9
1
4
0
1
,
T
e
l
:
(
8
1
8
)
9
1
6
-
6
8
9
6
PR
O
P
O
S
E
D
:
S
W
I
M
M
I
N
G
P
O
O
L
AD
D
R
E
S
S
:
2
2
2
4
C
O
N
C
O
R
D
S
T
DATE: 1-NOV-2023
JOB :
th
e
o
d
o
r
e
c
r
i
s
t
e
s
c
u
@
y
a
h
o
o
.
c
o
m
EDDIE
PR
E
P
A
R
E
D
F
O
R
:
1 SITE PLAN N
(E)
SINGLE FAMILY DWELLING
TWO STORIES
3,318.00 SQ.FT.
(E)
GARAGE
204.00 SQ.FT.
(E)
PATIO COVER
425.70 SQ.FT.
2224 CONCORD ST
15
'
-
1
0
"
(N)ADU
759.00SQ.FT.
5'-0"
5'-5"
E
S
A
N
T
A
C
L
A
R
A
A
V
E
(N) SWIMMING POOL
(N) POOL
EQUIPMENT
8'-0"
DEEP
8'
-
2
"
POOL CONSTRUCTION NOTES:
1.POOL ENCLOSURE TO BE AT LEAST 60 INCHES ABOVE GRADE MEASURED ON THE SIDE OF THE BARRIER THAT FACES AWAY FROM THE SWIMMING POOL.
2.POOL ENCLOSURE GATES SHALL OPEN OUTWARD AWAY FROM THE POOL AND SHALL BE SELF-CLOSING AND SELF-LATCHING. THE LATCH TO BE MINIMUM 4.5 FEET ABOVE THE GROUND.
3.THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS,
VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE
LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES.
4.AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWNSTREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE
BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 170, 158) SEPARATE PLUMBING PERMIT IS REQUIRED.
5.POOL ENCLOSURE:THE TOP OF THE BARRIER SHALL BE AT LEAST 60 INCHES ABOVE GRADE MEASURED ON THE SIDE OF THE BARRIER THAT FACES AWAY FROM THE SWIMMING POOL. THE MAXIMUM
VERTICAL CLEARANCE BETWEEN GRADE AND THE BOTTOM OF THE BARRIER SHALL BE 2 INCHES MEASURED ON THE SIDE OF THE BARRIER THAT FACES AWAY FROM THE SWIMMING POOL. THE GATE
SHALL OPEN OUTWARD AWAY FROM THE POOL AND SHALL BE SELF-CLOSING AND HAVE A SELF-LATCHING DEVICE. THE LATCH SHALL BE LOCATED A MINIMUM 54 INCHES ABOVE THE GROU 3109.4.1.7,
6109(A)
6.PROVIDE AN ALARM FOR DOORS TO THE DWELLING THAT FORM A PART OF THE POOL ENCLOSURE. THE ALARM SHALL PROVIDE AN AUDIBLE WARNING WHEN THE DOOR OR ITS SCREEN, IF PRESENT, ARE
OPENED. THE ALARM(S) SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 2017 AND INDEPENDENTLY CERTIFIED TO THE ASTM STANDARD F2208. THE ALARMS SHALL BE EQUIPPED WITH A
DEACTIVATION SWITCH LOCATED IN ACCORDANCE 54” ABOVE THE FLOOR FOR UNITS NOT REQUIRED TO BE ACCESSIBLE AND BETWEEN 48 AND 54 INCHES FOR UNITS REQUIRED TO BE ACCESSIBLE.
3109.4.1.8, 3109.4.4.2
7.SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ANSI/APSP-7 (3109.5)
8.A MINIMUM OF (2) DROWNING PREVENTING SAFETY FEATURES SHALL BE INSTALLED PER Section 3109.2 ON THE BUILDING CODE AND SECTION 11592 OF THE CALIFORNIA SWIMMING POOL SAFETY ACT
ADDITIONAL PLAN NOTES:
VERIFY WATER DEPTH WITH OWNER PRIOR TO EXCAVATION.
SPA SEATING AND JETS TO BE DISCUSSED WITH OWNER PRIOR TO PLUMBING LAYOUT.
FINISHES TO BE DETERMINED BUY CONTRACTOR AND OWNER
PRIOR TO START WORK.
YARD ELEVATIONS AND DRAINAGE TO BE DETERMINED PRIOR TO EXCAVATION.
DECKS TO SLOPE 2% AWAY FROM DWELLING AND FROM POOL.
PROVIDE YARD/DECK DRAINS TO APPROVED LOCATION.
N
NOTES:
PROVIDE ALL EXTERIOR DOORS
WITH POOL SAFETY ALARMS PER
CITY STANDARD
PROVIDE WATER MOTION POOL
SAFETY ALARM
(E) 6'-0" HIGH
SELF-CLOSING
SELF-LATCHING
GATE
w/ COMPLIANT
LATCH
(E) 5'-6" HIGH FENCE
(E
)
5
'
-
6
"
H
I
G
H
F
E
N
C
E
3'-3"
3'
-
0
"
Provide pool alarm that complies with ASTM F2208, capable of detecting unauthorized entry into the water. The alarm shall:
Be independently certified to meet ASTM F2208.
Sound an audible alarm both in the pool area and within the home.
Not rely solely on perimeter or door alarms.
Detect surface or subsurface disturbances caused by unintended entry
SCOPE OF WORK: NEW SWIMMING POOL
ALL WORK TO COMPLY WITH 2022 CBC
(N) 18"
RAISED
SPA 4'
DEEP
4'-0"
DEEP
5'-0"
7'-0"
7'
-
0
"
12
'
-
0
"
(N) BAJA
6'
-
0
"
6'-0"
Digitally signed by Matthew Thompson on 06/04/2025 - 1749020400 - 24-01135-dg
100
Revision to 101120081 (issued
on 6/11/25)
REV 1 #101124789
APPROVALS:
PLNG - C. Santana
BLDG - A. So
PUBLIC WORKS - B. Sarlak
Digitally signed by Matthew Thompson on 06/04/2025 - 1749020400 - 24-01135-dg