Loading...
HomeMy WebLinkAbout709 W Jonquil Rd - Plan Name: Michael Yi Address: 709 W Jonquil Rd, Santa Ana, CA 92706 I give permission to Solar Optimum to install 8.26 KW PV SYSTEM 19 PV Modules 1-TESLA POWERWALL 3 ESS at the above property. Thank you, 1833 S. Victory Blvd. Glendale, CA 91201 Toll-Free 800.552.9970 | Office 818.804.3122 | Fax 818.804.3123 www.SolarOptimum.com Docusign Envelope ID: 73FFCFFE-2960-4516-9D2D-30DD45889A43 10/6/2025 Certificate Of Completion Envelope Id: 73FFCFFE-2960-4516-9D2D-30DD45889A43 Status: Completed Subject: Complete with Docusign: Homeowner authorization letter to install solar panels.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 4 Initials: 0 Permitting Team AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 614 W Colorado St Glendale, CA 91204-1104 permitting@solaroptimum.com IP Address: 104.15.149.101 Record Tracking Status: Original 10/6/2025 1:27:55 PM Holder: Permitting Team permitting@solaroptimum.com Location: DocuSign Signer Events Signature Timestamp Michael YI michaelyi1203@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Drawn on Device Using IP Address: 76.175.216.215 Signed using mobile Sent: 10/6/2025 1:28:22 PM Viewed: 10/6/2025 2:49:31 PM Signed: 10/6/2025 2:49:51 PM Electronic Record and Signature Disclosure: Accepted: 8/28/2025 1:21:58 PM ID: df1dd282-986f-4b8c-add9-5a58f64f1281 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 10/6/2025 1:28:22 PM Certified Delivered Security Checked 10/6/2025 2:49:31 PM Signing Complete Security Checked 10/6/2025 2:49:51 PM Completed Security Checked 10/6/2025 2:49:51 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, Solar Optimum, Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to these terms and conditions, please confirm your agreement by clicking the ‘I agree’ button at the bottom of this document. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures Electronic Record and Signature Disclosure created on: 9/24/2015 10:32:27 AM Parties agreed to: Michael YI electronically from us. How to contact Solar Optimum, Inc. : You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: accounting@solaroptimum.com To advise Solar Optimum, Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at accounting@solaroptimum.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address.. In addition, you must notify DocuSign, Inc. to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from Solar Optimum, Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an e-mail to accounting@solaroptimum.com and in the body of such request you must state your e-mail address, full name, US Postal address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with Solar Optimum, Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an e-mail to accounting@solaroptimum.com and in the body of such request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that: • I can access and read this Electronic CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC RECORD AND SIGNATURE DISCLOSURES document; and • I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and • Until or unless I notify Solar Optimum, Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by Solar Optimum, Inc. during the course of my relationship with you. Solar Optimum, Inc., 614 W. Colorado St., Glendale, CA 91204 Tel: (818)745-1475 Page 1 of 9 STRUCTURAL CALCULATIONS for SOLAR ELECTRIC SYSTEM FOR MICHAEL YI AT 709 W JONQUIL RD, SANTA ANA, CA 92706, USA PROJECT : PAGE : CLIENT : DESIGN BY : JOB NO. : DATE : REVIEW BY : INPUT DATA Exposure category (B, C or D) Importance factor, pg 77, (0.87, 1.0 or 1.15)I =Category II Basic wind speed (IBC Tab 1609.3.1V3S)V =mph Topographic factor (Sec.6.5.7.2, pg 26 & 45)Kzt =Flat Building height to eave he =ft Building height to ridge hr =ft Building length L =ft Building width B =ft Effective area of components A =11 ft2 DESIGN SUMMARY Max horizontal force normal to building length, L, face =21.49 kips Max horizontal force normal to building length, B, face =23.33 kips Max total horizontal torsional load =188.16 ft-kips Max total upward force =70.99 kips ANALYSIS Velocity pressure qh = 0.00256 Kh Kzt Kd V2 I =psf where:qh = velocity pressure at mean roof height, h. (Eq. 6-15, page 27) Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-3, Case 1,pg 79)=0.91 Kd = wind directionality factor. (Tab. 6-4, for building, page 80)=0.85 h = mean roof height =21.50 ft < 60 ft, [Satisfactory] < Min (L, B), [Satisfactory] Design pressures for MWFRS p = qh [(G Cpf )-(G Cpi )] where:p = pressure in appropriate zone. (Eq. 6-18, page 28).pmin =10 psf (Sec. 6.1.4.1 & 6.1.4.2) G Cp f = product of gust effect factor and external pressure coefficient, see table below. (Fig. 6-10, page 53 & 54) G Cp i = product of gust effect factor and internal pressure coefficient.(Fig. 6-5, Enclosed Building, page 47) =0.18 or -0.18 a = width of edge strips, Fig 6-10, note 9, page 54, MAX[ MIN(0.1B, 0.4h), 0.04B,3] =6.00 ft Net Pressures (psf), Basic Load Cases Net Pressures (psf), Torsional Load Cases 13.13 0.00 13.13 (+GCp i )(-GCp i )(+GCp i )(-GCp i )(+GCp i )(-GCp i ) 1 0.47 6.98 15.62 0.40 5.28 13.93 1T 0.47 1.74 3.91 2 -0.69 -20.89 -12.25 -0.69 -20.89 -12.25 2T -0.69 -5.22 -3.06 3 -0.43 -14.64 -5.99 -0.37 -13.21 -4.56 3T -0.43 -3.66 -1.50 4 -0.37 -13.11 -4.46 -0.29 -11.29 -2.64 4T -0.37 -3.28 -1.12 1E 0.71 12.80 21.44 0.61 10.33 18.97 0.00 2E -1.07 -30.02 -21.37 -1.07 -30.02 -21.37 3E -0.62 -19.13 -10.49 -0.53 -17.05 -8.40 (+GCp i )(-GCp i ) 4E -0.54 -17.38 -8.74 -0.43 -14.65 -6.00 1T 0.40 1.32 3.48 5 -0.45 -15.13 -6.48 -0.45 -15.13 -6.48 2T -0.69 -5.22 -3.06 6 -0.45 -15.13 -6.48 -0.45 -15.13 -6.48 3T -0.37 -3.30 -1.14 4T -0.29 -2.82 -0.66 Net Pressure withG Cp f Roof angle q = G Cp f Net Pressure with Roof angle q = G Cp f Net Pressure with Surface Roof angle q = G Cp f Net Pressure withSurface Roof angle q = Surface Wind Analysis for Low-rise Building, Based on ASCE 7-16 / IBC 2021 / CBC 2022 C 1.00 110 1 18 22.38 Page 2 of 9 25 60 40 MICHAEL YI 709 W JONQUIL RD, SANTA ANA, CA 92706 LOAD CRITERIA WEIGHT OF MODULE 45 LB MODULE LENGTH 5.975 FT MODULE WIDTH 3.33 FT MODULE AREA 19.90 FT^2 UNIT WT OF MODULE 2.26 PSF AVG RACKING WT 0.3 PSF TOTAL AVG WT (MODULE+RACKING)2.56 PSF NO OF MODULE 19 CONNECTION POINT TRIB LENGTH 6 FT CONNECTION POINT TRIB WIDTH 6 FT MAX. SPACING CONN POINT TRIB. AREA 36 FT^2 LOAD PER CONN PT LOAD 92 LB ROOF SLOPE 21.00 DEGREE SLIING FORCE 33.04 LB LOAD*SIN(ROOF SLOPE ) LOAD ON EXISTING ROOF 1) ROOFING 10.00 PSF 2) 5/8" PLYWOOD 1.8 PSF 3) ROOF RAFTER 3.1 PSF 4) INSULATION 1.5 PSF 5) MISC 1.5 PSF TOTAL DL 17.90 PSF ROOF AREA 2400 SF TOTAL ROOF WT 42.96 KIP WALL WT 2.40 KIP TOTAL BUILDING DL 45.36 KIP EACH MODULE AREA 19.90 TOTAL AREA OF MODULE 378.04 SF TOTAL MODULE WT 2.27 KIP ADDITIONAL DL ADDED TO EXISTING BUILDING 5.00 % LATERAL LOAD ANALYSIS COMMENTS SINCE TOTAL ADDED DL TO THE BUILDING IS LESS THAN 10%, PER CBC 2022 EXISTING LATERAL RESISTING ELEMENTS WILL NOT BE AFFECTED VERTICAL LOAD ANALYSIS COMMENTS PER CBC SECTION 1607.13.5.1 EXCEPTION 1, THE ROOF LL NEED NOT TO BE APPLIED TO THE AREA OCCUPIED BY THE SOLAR MODULES WHERE THE CLEAR SPACE BETWEEN PANELS AND ROOF SURFACE IS 24" OR LESS. THEREFORE, DESIGN LOAD BY ADDING SOLAR MODULE OF 2.75 PSF IS LESS THAN WITHOUT MODULES AND HENCE EXISTING FRAMING WILL THEREFORE BE OK. Page 3 of 9 MICHAEL YI 709 W JONQUIL RD, SANTA ANA, CA 92706 CONNECTION DESIGN VELOCITY PRESSURE, qh 22.38 PSF (SEE WIND LOAD CALC) A) LATERAL FORCE Fh FOR ROOFTOP STRUCTURES (FOR ONE CONN POINT) (ONE SCREW PER CONN POINT) HORIZONTAL WIND FORCE, Fh = qh * Gcr * Af ASCE 7-16, Eq. 29.4.4 WIDTH OF BUILDING, B 40 FT MEAN HEIGHT OF BLDG, H 24 FT CONNECTION POINT TRIB LENGTH, l 6 FT MAX. SPACING CONNECTION POINT PROJECTED HEIGHT, h0.99 FT [2.75' SIN(ROOF SLOPE)] VERTICAL PROJECTED AREA, Af 5.91 FT^2 Gcr 1.9 IF(B*H*0.1>Af,1.9)ASCE 7-16, Eq. 29.4.4 WIND LATERAL FORCE, Fh 251.4 LB SLIDING FORCE 33.04 DESIGN LATERAL FORCE 284.43 B) VERTICAL FORCE Fv FOR ROOFTOP STRUCTURES ( (FOR ONE CONN POINT) VERTICAL WIND FORCE, Fv = qh * Gcr * Ar ASCE 7-16, Eq. 29.4.4 WIDTH OF BUILDING, B 40 FT LENGTH OF BLDG, L 60 FT CONNECTION POINT TRIB LENGTH, l 6 FT CONNECTION POINT TRIB WIDTH, w 2.57 FT [2.75' COS(ROOF SLOPE)] HORIZONTAL PROJECTED AREA, Ar 15.40 FT^2 Gcr 1.4 IF(B*L*0.1>Ar,1.5)ASCE 7-16, Eq. 29.4.4 WIND VERTICAL FORCE, Fv 482.7 LB DESIGN WITHDRAWL FORCE 482.7 Page 4 of 9 MICHAEL YI 709 W JONQUIL RD, SANTA ANA, CA 92706 CONNECTION DESIGN DESIGN LATERAL FORCE 284.433 USE LAG SCREW 5/16"INCH CAPACITY PER ONE SCREW, ZII 210 LB (NDS 2021 REFERENCE DESIGN VALUE, SEE ATTACHED) DESIGN CAPACITY, ZII '558.6 LB DESIGN IS GOOD DESIGN WITHDRAWL FORCE 482.653 USE LAG SCREW 5/16"INCH WITHDRAWL CAPACITY 266 LB (NDS 2021 REFERENCE DESIGN VALUE, SEE ATTACHED) DESIGN WITHDRAWL CAPACITY 884.45 LB DESIGN IS GOOD COMBINED WIND SHEAR/UPLIFT 0.30 0.259 0.56 < 1.0 DESIGN IS GOOD (UPLIFT)(SHEAR) USE (2) 5/16" DIA X 3 1/2" LONG 2.5" MIN EMBEDMENT LAG SCREW PER CONNECTION POINT Page 5 of 9 MICHAEL YI 709 W JONQUIL RD, SANTA ANA, CA 92706 BATTERY CALCULATION LOAD CRITERIA WEIGHT OF BATTERY 287 LB MODULE LENGTH 45.3 INCH MODULE WIDTH 29.7 INCH LOAD PER CONN PT LOAD 72 LB WALL MOUNTAIN 90.00 DEGREE SLIING FORCE 71.75 LB LOAD*SIN(ROOF SLOPE ) Page 6 of 9 MICHAEL YI 709 W JONQUIL RD, SANTA ANA, CA 92706 BATTERY CALCULATION CONNECTION DESIGN DESIGN LATERAL FORCE 71.75 USE LAG SCREW 3/8 INCH CAPACITY PER ONE SCREW, ZII 200 LB (NDS 2018 REFERENCE DESIGN VALUE, SEE ATTACHED) DESIGN CAPACITY, ZII '266 LB DESIGN IS GOOD DESIGN WITHDRAWL FORCE 71.75 USE LAG SCREW 3/8 INCH WITHDRAWL CAPACITY 305 LB (NDS 2018 REFERENCE DESIGN VALUE, SEE ATTACHED) DESIGN WITHDRAWL CAPACITY 1419.78 LB DESIGN IS GOOD COMBINED WIND SHEAR/UPLIFT 0.00 0.073 0.08 < 1.0 DESIGN IS GOOD (UPLIFT)(SHEAR) USE (4) 3/8" DIA X 3-1/2" LONG 2.5" MIN THREAD EMBEDMENT LAG SCREW PER BATTERY Page 7 of 9 Page 8 of 9 Page 9 of 9 60.06' 60.01' 10 4 . 5 7 ' 10 1 . 0 0 ' 24 ' - 0 " 40 ' - 2 " 2'-3" 6'-8" MSP UM ACD DCD ACDPW3 JB 1 COVER PAGE PV-1 SCALE: NTSPV-1 2 VICINITY MAP SCALE: NTSPV-1 1 HOUSE PHOTO COVER PAGE SHEET INDEX PV-1 COVER PAGE PV-2 ROOF PLAN & MODULES PV-3 STRING LAYOUT PV-4 ATTACHMENT DETAIL PV-4.1 BUILDING & WALL ELEVATION PV-4.2 BATTERY MOUNTING DETAILS PV-5 SINGLE LINE DIAGRAM PV-6 WIRING CALCULATION PV-7 PLACARDS PV-8+ EQUIPMENT SPECIFICATIONS AHJ: SANTA ANA CITY COUNTY- ORANGE COUNTY SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI SCALE: 1/16" = 1'-0" SCOPE OF WORK: GOAL : 11,219 kWh PV PRODUCTION : 10,337 kWh DC SYSTEM SIZE: 19 X 435 = 8.265 kW DC AC SIZE: 7.58 KW CEC MODULES: (19) MISSION SOLAR: MSX10-435HN0B (435W) MODULES INVERTER: (01) TESLA POWERWALL 3 (INTEGRATED SOLAR BATTERY SYSTEM), 11.5kW, 13.5kWh PANEL: (E) 200A MAIN PANEL, (E) 200A MAIN BREAKER AC DISCONNECT: (N) PV/BATTERY FUSED DISCONNECT 60A, 1PH, 240VAC NEMA 3R AC DISCONNECT: (N) PV/BATTERY DISCONNECT 60A, 1PH, 240VAC NEMA 3R BATTERY: (N) (01) TESLA POWERWALL 3 BACKUP SWITCH: (N) TESLA BACKUP SWITCH DC DISCONNECT: (N) DC DISCONNECT, IMO 600V: SI16-PEL64R-2 MCI-2 : (N) 07 - SOLAR SHUTDOWN DEVICE SUB PANEL: (E) 70A RATED SUB PANEL,240V (INSIDE GARAGE) NOTES: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. THE BACKFEED BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE MAIN BREAKER OR INPUT FEEDER. TERMINATION POINTS FOR ELECTRICAL EQUIPMENT ARE RATED FOR 60/75 DEGREES CELSIUS. BUILDING INFORMATION 1-STORY HOUSE SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE : V-B OCCUPANCY : R3 FIRE SPRINKLER : NO ROOF : COMP. SHINGLE APN : 002-037-14 ARRAY LOCATION PROJECT SITE GOVERNING CODES THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA PLUMBING CODE 2020 NATIONAL ELECTRICAL CODE ALL OTHER ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGENCIES. (E) DETACHED GARAGE ROOF #02 (05) MISSION SOLAR: MSX10-435HN0B 435W MODULES (E) FENCE (N) JUNCTION BOX (N) TESLA POWERWALL 3 (INTEGRATED SOLAR BATTERY SYSTEM), 11.5KW, 13.5KWH (N) 60A PV/BATTERY FUSED DISCONNECT (E) 200A MAIN SERVICE PANEL, 240V (E) UTILITY METER (N) TESLA BACKUP SWITCH (E) GATE (N) DC DISCONNECT (N) 60A PV/BATTERY DISCONNECT PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E 1-STORY HOUSE W JONQUIL RD EX I S T I N G DR I V E W A Y (E) SHED ROOF #01 (11) MISSION SOLAR: MSX10-435HN0B 435W MODULES ROOF #03 (03) MISSION SOLAR: MSX10-435HN0B 435W MODULES Elect #20187087 APPROVALS: ELECT - M. Smith ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. *** 18" F I R E S E T B A C K 18" F I R E S E T B A C K 18" F I R E S E T B A C K 18" F I R E S E T B A C K 18" F I R E S E T B A C K 18" F I R E S E T B A C K MSP UM ACD DCD ACDPW3 JB 18" FIRE SETBACK 18" FIRE SETBACK 18" F I R E S E T B A C K 18" F I R E S E T B A C K 18" F I R E S E T B A C K 18" F I R E S E T B A C K 36" F I R E S E T B A C K 18" FIRE SETBACK 18" FIRE SETBACK 5' - 1 1 " 11 ' - 5 " 6' - 2 " 3'-9"7'-6"1'-10" 3'-11"19'-0" 1'-0" 9' - 5 " 19 ' - 1 1 " 9' - 9 " 3"5'-8"1'-10" SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI ROOF PLAN & MODULES SCALE: 1/8" = 1'-0" 1 PV-2 ROOF PLAN & MODULES MISSION SOLAR: MSX10-435HN0B 435W MODULES 44.73" 67 . 8 " MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 19 MODULES MODULE TYPE = MISSION SOLAR: MSX10-435HN0B 435W MODULES MODULE DIMENSIONS = 67.8"x 44.73" = 21.06 SF MODULE WEIGHT = 46.96 LBS / 21.3 KG. TOTAL WEIGHT: (19)1.5 + (07)0.26+ (19)46.96 = 922LBS. WEIGHT PER CONNECTION: 922 LBS / 45 STANDOFF = 20.50 LBS TOTAL ARRAY AREA = 400.14 SF DISTRIBUTED LOAD = 922 LBS / 400.14 SF = 2.31 PSF ARRAY AREA WITH WHOLE ROOF AREA ROOF # OF MODULES TOTAL ARRAY AREA (SQ. FT.) WHOLE ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1-#3 19 400.14 1616.41 24.75 ARRAY AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 11 231.55 380.00 60.93 #2 05 105.25 331.69 31.73 #3 03 63.15 153.35 41.18 ROOF DESCRIPTION TABLE ROOF TYPE COMP. SHINGLE ROOF ROOF TILT AZIMUTH RAFTER SIZE RAFTER SPACING #1 21°180°2"x4"24" O.C. #2 21°270°2"x4"24" O.C. #3 21°90°2"x4"24" O.C. OCCUPANCY CLASS: R3 CONSTRUCTION TYPE: V-B CBC/CRC EDITION: 2022 (N) UNIRAC SM LIGHT RAIL (45) UNIRAC FLASHLOC DUO ATTACHMENTS @ 72" O.C. (N) 07 - SOLAR SHUTDOWN DEVICE (MCI-2) - ROOF #02 (05) MISSION SOLAR: MSX10-435HN0B 435W MODULES 3/4" EMT CONDUIT RUN ON ROOF (N) JUNCTION BOX (E) CHIMNEY ROOF ACCESS POINT (N) TESLA POWERWALL 3 (INTEGRATED SOLAR BATTERY SYSTEM), 11.5KW, 13.5KWH (N) 60A PV/BATTERY FUSED DISCONNECT (E) 200A MAIN SERVICE PANEL, 240V (E) UTILITY METER (N) TESLA BACKUP SWITCH (N) DC DISCONNECT (N) 60A PV/BATTERY DISCONNECT ROOF #01 (11) MISSION SOLAR: MSX10-435HN0B 435W MODULES ROOF #03 (03) MISSION SOLAR: MSX10-435HN0B 435W MODULES W JONQUIL RD ROOF #1 TILT - 21° AZIM. - 180° ROOF #2 TILT - 21° AZIM. - 270° ROOF #3 TILT - 21° AZIM. - 90° (E) BACK OF RESIDENCE (E) FRONT OF RESIDENCE MSP UM ACD DCD ACDPW3 JB STRING LAYOUT SCALE: 1/8" = 1'-0" 1 PV-3 SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI STRING LAYOUT BILL OF MATERIALS EQUIPMENT QTY SOLAR PV MODULE 19 MCI-2 07 TESLA POWERWALL 3 1 TESLA BACKUP SWITCH 1 JUNCTION BOX 1 60A PV/BATTERY FUSED DISCONNECT 1 60A PV/BATTERY DISCONNECT 1 DC DISCONNECT 1 RAILS 168"12 RAIL SPLICE 2 MID CLAMPS 24 END CLAMPS 28 ATTACHMENT 45 GROUNDING LUG 7 STRING 1 STRING 2 STRING 3 STRING 4 W JONQUIL RD (E) BACK OF RESIDENCE (E) FRONT OF RESIDENCE 6" M A X SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI ATTACHMENT DETAIL SCALE: NTS 2 PV-4 ATTACHMENT DETAIL SCALE: NTS 1 PV-4 ATTACHMENT DETAIL (ENLARGED VIEW) PV MODULE (E) COMP. SHINGLE PV MODULEUNIRAC SOLAR RACKING UNIVERSAL END CLAMP (OR GROUNDING MID CLAMP) ALUMN "L" BRACKET W3/8" SS BOLT & NUT UNIRAC SM LIGHT RAIL (E) COMP. SHINGLE UNIRAC FLASHLOC DUO ATTACHMENTS (2) 5/16"x3.5" SS LAG BOLT WITH MIN 2.5" THREAD EMBEDMENT, SEALED PENETRATION 2"X 4" RAFTER @ 24" O.C. FLASHING SEE FOR ENLARGED VIEW 2"X 4 " R A F T E R @ 2 4 " O . C . 2' - 2 " MI N . 10 ' - 0 " 16 ' - 5 " 15 ' - 5 " 2' - 2 " MI N . SCALE: 3/8" = 1'-0" 2 PV-4.1 WALL ELEVATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4.1 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI BUILDING & WALL ELEVATION SCALE: 3/16" = 1'-0" 1 PV-4.1 BUILDING ELEVATION NORTH SIDE OF WALL ELEVATION (N) PV ARRAY (TYP.) (E) 200A MAIN SERVICE PANEL, 240V (E) UTILITY METER (N) TESLA BACKUP SWITCH (N) DC DISCONNECT (N) 60A PV/BATTERY DISCONNECT (N) TESLA POWERWALL 3 (INTEGRATED SOLAR BATTERY SYSTEM), 11.5KW, 13.5KWH (N) 60A PV/BATTERY FUSED DISCONNECT (E) 70A RATED SUB PANEL,240V (INSIDE GARAGE) VENT VENT VENT WI N D O W SOUTH SIDE OF WALL ELEVATION (E) CHIMENY (E) WINDOW (TYP.)(E) DOOR (N) TESLA POWERWALL 3 (INTEGRATED SOLAR BATTERY SYSTEM), 11.5KW, 13.5KWH (N) 60A PV/BATTERY FUSED DISCONNECT SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4.2 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI BATTERY MOUNTING DETAILS BATTERY MOUNTING DETAILS SCALE: 1" = 1'-0" 1 PV-4.2 TESLA POWERWALL 3 MOUNTING DETAILS (4) 3/8" x 3-1/2" LAG BOLTS W/ MIN. 2-1/2" EMBEDMENT (2 TOP & 2 BOTTOM) IN TO (E) STUDS USING 2 STUDS MIN. TESLA POWERWALL 3 (E) 2"X4" WALL STUDS 2' - 2 " M I N . SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI SINGLE LINE DIAGRAM SCALE: N.T.S 1 PV-5 SINGLE LINE DIAGRAM SERVICE INFO UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MSP BUS RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V SCE NORTH EATON 200 A (EXISTING) OVERHEAD 19 - MISSION SOLAR: MSX10-435HN0B 435W MODULES 07 - SOLAR SHUTDOWN DEVICE (MCI-2) 01 - TESLA POWERWALL 3 (INTEGRATED SOLAR BATTERY SYSTEM), 11.5kW, 13.5kWh 01- TESLA BACKUP SWITCH (01) STRING OF 06 MODULES CONNECTED IN SERIES. (02) STRINGS OF 05 MODULES CONNECTED IN SERIES. (01) STRING OF 03 MODULES CONNECTED IN SERIES. MAIN BREAKER RATING:200 A (EXISTING) Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) Tag # 1 1 2 2 3 STRANDED BARE COPPER GROUND (EGC/GEC) THWN-2 PV WIRE THWN-2 - Ground THWN-2 THWN-2 - Ground Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size 10 AWG 6 AWG (NOT IN CONDUIT) 10 AWG 8 AWG 8 AWG 8 (4V+, 4V-) B/R 1 BARE 8 (4V+, 4V-) B/R 1 (GRN) 3 (1L1, 1L2, 1N) B/R/W 1 (GRN) EMT 3/4" 3/4"EMT EMT EMT3 6 AWG - 3/4" 3/4" - - - (OR EQUIVALENT) (OR EQUIVALENT) (OR EQUIVALENT) (OR EQUIVALENT) (OR EQUIVALENT) (OR EQUIVALENT) (OR EQUIVALENT) (OR EQUIVALENT) (OR EQUIVALENT) (OR EQUIVALENT) MINIMUM MOUNTING HEIGHT OF CABLES IS 7/8 INCHES ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. THE BACKFEED BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE MAIN BREAKER OR INPUT FEEDER. TERMINATION POINTS FOR ELECTRICAL EQUIPMENT ARE RATED FOR 60/75 DEGREES CELSIUS. NOTES: (N) 19 - MISSION SOLAR: MSX10-435HN0B 435W MODULES 21 3 (N) JUNCTION BOX 600V, NEMA 3 UL LISTED 1 DC AC (N) TESLA POWERWALL 3 (INTEGRATED SOLAR BATTERY SYSTEM), 11.5kW, 13.5kWh BATTERY MCI2 21 3 MCI2 MCI2 MCI2 4 2 G GROUNDING ELECTRODE SYSTEM 200A M BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V UTILITY PROVIDER: SCE UTILITY METER NO: 304 069 022 (E) MAIN SERVICE PANEL, 200A BUS RATED, 240V TO UTILITY GRID (N) TESLA BACKUP SWITCH USE TANDEM BREAKER TO MAKE ROOM FOR PV BREAKER 4 3 (E) 200A MAIN BREAKER (N) 60A/2P PV BREAKER (2) #14 THWN-2 (N) DC DISCONNECT, IMO 600V: SI16-PEL64R-2 5 (N) 07 - SOLAR SHUTDOWN DEVICE (MCI-2) 3 SHIELDED VNTC CABLE (600V) (4) #18 AWG THWN-2 60A 21 3 MCI2 MCI2 54 PCS CONTROLLED BUSBAR 120% RULE - NOT APPLICABLE THIS DESIGN EXCEEDS THE 120% RULE AS 705.12 COMPLIANCE IS NOT APPLICABLE FOR THIS PCS CONTROLLED SYSTEM. THE PROVISIONS OF 705.13 SUPERSEDE AND OVERRIDE ANY REQUIREMENTS STIPULATED UNDER 705.12 FOR THIS SPECIFIC SETUP. DOCUMENTATION ON PCS BUSBAR PROTECTION IS PROVIDED IN SPEC SHEETS. 705.13(A): Monitoring The PCS controller shall monitor all currents within the PCS. Any busbar or conductor on the load side of the service disconnecting means that is not monitored by the PCS shall comply with 705.12. NOTE: THE MAXIMUM OPERATING CURRENTS IN CONTROLLED BUSBARS OR CONDUCTORS ARE LIMITED BY THE SETTINGS OF THE POWER CONTROL SYSTEM (PCS) AND MAY BE LOWER THAN THE SUM OF THE CURRENTS OF THE CONNECTED CONTROLLED POWER SOURCES. THE SETTINGS OF THE PCS CONTROLLED CURRENTS MAY BE USED FOR CALCULATION OF THE DESIGN CURRENTS USED IN THE RELEVANT SECTIONS OF NEC ARTICLE 690 AND 705. 21 3 MCI2 3 BUS BAR OVERLOAD PROTECTION USED TO LIMIT CONTINUOUS CURRENT ON BUS BAR TO 160A. THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM TOWARDS THE MAIN PANEL IS CONTROLLED ELECTRONICALLY. PCS LABEL MAXIMUM CURRENT SETTING: 160A DATE OF CALCULATION AND SETTING: 17/SEP/2025 IDENTIFICATION OF LOADS AND SOURCES ASSOCIATED WITH THE CURRENT LIMITING FEATURE: POWERWALL 3 INVERTER OUTPUT "THE SETTING FOR THE PCS CURRENT LIMITING FEATURE SHALL NOT BE BYPASSED" 60A (N) PV/BATTERY DISCONNECT 60A, 1PH, 240VAC NEMA 3R (N) PV/BATTERY FUSED DISCONNECT 60A, WITH 60A FUSED 1PH, 240VAC NEMA 3R 6 5 SYSTEM SIZE: TOTAL DC SYSTEM SIZE: 8.265 kW STC DC TOTAL AC SYSTEM SIZE: 7.58 kW CEC AC SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI WIRING CALCULATION SCALE: N.T.S 1 PV-6 WIRING CALCULATION ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 75 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 INVERTER SPECIFICATIONS MANUFACTURER / MODEL #TESLA POWERWALL 3 NOMINAL OUTPUT CURRENT 48A NOMINAL OUTPUT VOLTAGE 240 VAC AMBIENT TEMPERATURE SPECS AMBIENT TEMP (HIGH TEMP 2%)33° CONDUIT HEIGHT 7/8" ROOF TOP TEMP 33° CONDUCTOR TEMPERATURE RATE ON ROOF 75° CONDUCTOR TEMPERATURE RATE OFF ROOF 75° DC CONDUCTOR AMPACITY CALCULATIONS: FROM ROOF TOP JUNCTION BOX TO TESLA POWERWALL 3 AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT EXPECTED WIRE TEMP (°C): 33° TEMP CORRECTION PER TABLE 310.15: 0.94 #OF CURRENT CARRYING CONDUCTORS: 08 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 0.70 CIRCUIT CONDUCTOR SIZE: 10 AWG CIRCUIT CONDUCTOR AMPACITY: 35A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): 1.25 X MODULES ISC CURRENT PER STRING STRING #1 : 1.25 X 13.79 = 17.24A STRING #2 : 1.25 X 13.79 = 17.24A STRING #3 : 1.25 X 13.79 = 17.24A STRING #4 : 1.25 X 13.79 = 17.24A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15 TEMP CORR. PER NEC TABLE 310.15 X CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.94 X 0.70 X 35 = 23.03A EXPECTED WIRE TEMP (°C): 33° TEMP CORRECTION PER NEC TABLE 310.15: 0.94 CIRCUIT CONDUCTOR SIZE: 6 AWG CIRCUIT CONDUCTOR AMPACITY: 65A #OF CURRENT CARRYING CONDUCTORS: 3 CONDUIT FILL PER NEC 310.15(B)(2)(a): 1.00 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): 1.25 X OUTPUT CURRENT OF TESLA POWERWALL 3 1.25 X 48 = 60.00A DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.15: TEMP CORR. PER NEC 310.15 X CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.94 X 1.00 X 65 = 61.10A AC CONDUCTOR AMPACITY CALCULATIONS: FROM TESLA POWERWALL 3 TO (EX.) MSP: MSP UM ACD DCD ACD PW3 SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI PLACARDS CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN THE PROJECT SHALL COMPLY WITH THE CURRENT VERSION OF THE DEPARTMENT ELECTRICAL POWER SOURCE DISCONNECT PLACARDING SYSTEM ENERGY STORAGE SYSTEM 1.MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE,WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. 2.ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITH MINIMUM 3/8" LETTER HEIGHT,WHITE ON RED BACKGROUND. 3.MAIN SERVICE DISCONNECT MARKING SHALL BE PLACED ADJACENT TO MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER IS OPERATED. 4.MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS,ENCLOSURES,CABLE ASSEMBLIES,AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM.MARKING SHALL BE PLACED EVERY 10',AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS, AND AT ALL DC COMBINER AND JUNCTION BOXES. 5.DO NOT US SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE. SIGNAGE NOTES SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. 690.56(C)(1)(a) SIGNAGE LOCATIONS: MAIN SERVICE PANEL 6" X 3 1/2" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 690.13 (B) SIGNAGE LOCATIONS: MAIN SERVICE PANEL PV COMBINER BOX PV SYSTEM AC DISCONNECT INDOOR/OUTDOOR SUB PANEL WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL 110.27 (C) SIGNAGE LOCATIONS: MAIN SERVICE PANEL PV COMBINER BOX PV SYSTEM AC DISCONNECT INDOOR/OUTDOOR SUB PANEL PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEED CAUTION 690.13 (F), 705.12(B)(3-4) & 690.59 SIGNAGE LOCATIONS: PV COMBINER BOX INDOOR/OUTDOOR SUB PANEL WARNING! NEC 705.12 (B)(2)(c) SIGNAGE LOCATIONS: MAIN SERVICE PANEL INDOOR/OUTDOOR SUB PANEL POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM NEC 690.56(C)(3) SIGNAGE LOCATIONS: MAIN SERVICE PANEL WARNING LABEL LOCATION: BATTERY SUBPANEL PANELS THAT COMPLY WITH CEC 705.12(D)(2)(3)(C) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES,EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE,SHALL NOT EXCEED AMPACITY OF BUSBAR. WARNING LABEL LOCATIONS: BATTERIES INVERTER ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED !! ! ! ! RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM TRI POWER GRID, ESS AND PV WARNING 705.12(B)3-4 & 690.59 SIGNAGE LOCATIONS: MAIN SERVICE PANEL PV COMBINER BOX ! CAUTION TRI POWER SOURCE SECOND SOURCE IS AC BATTERY THIRD SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: SERVICE DISCONNECT SUBPANELS ! PHOTOVOLTAIC DC DISCONNECT RATED MAXIMUM POWER-POINT CURRENT: RATED MAXIMUM POWER-POINT VOLTAGE: MAXIMUM SYSTEM VOLTAGE: MAXIMUM SHORT CIRCUIT CURRENT: ADC VDC VDC ADC17.24 13.07 199.86 251.60 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S) MAXIMUM AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 48.00 AMPS 240 VAC PV/BATTERY FUSED DISCONNECT 690.54 SIGNAGE LOCATIONS: PV SYSTEM AC DISCONNECT SIGNAGE LOCATIONS: BATTERY BATTERY 1 OF 1 WARNING LABEL LOCATIONS: MAIN PANEL PANELS THAT COMPLY WITH CEC 705.12(D)(2)(3)(B) INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE ! MAIN SERVICE PANEL UTILITY METER BACKUP SWITCH BUS BAR OVERLOAD PROTECTION USED TO LIMIT CONTINUOUS CURRENT ON BUS BAR TO 160A. THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM TOWARDS THE MAIN PANEL IS CONTROLLED ELECTRONICALLY. PCS LABEL MAXIMUM CURRENT SETTING: 160A DATE OF CALCULATION AND SETTING: 17/SEP/2025 IDENTIFICATION OF LOADS AND SOURCES ASSOCIATED WITH THE CURRENT LIMITING FEATURE: POWERWALL 3 INVERTER OUTPUT "THE SETTING FOR THE PCS CURRENT LIMITING FEATURE SHALL NOT BE BYPASSED" LABEL LOCATIONS: MAIN SERVICE PANEL 2020 NEC.705.13 MAXIMUM AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 48.00 AMPS 240 VAC PV/BATTERY DISCONNECT 690.54 SIGNAGE LOCATIONS: PV SYSTEM AC DISCONNECT LABEL LOCATION: ESS Unit (S) DC DISCONNECT PV/BATTERY DISCONNECT PV ARRAY (TYP.) PV/BATTERY FUSED DISCONNET W JONQUIL RD SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-14 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-15 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-16 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-17 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-18 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-19 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI D 17" X 11" REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-20 M I C H A E L Y I 70 9 W J O N Q U I L R D , S A N T A AN A , C A 9 2 7 0 6 , U S A REVDATEDESCRIPTION NEW09/17/2025ORIGINAL PLAN CONTRACTOR SOLAR OPTIMUM INC. ADDRESS: 1833 S VICTORY BLVD, GLENDALE, CA 91201, USA TEL:(818)804-3122 LIC#: 972228, C-10 AP N : 00 2 - 0 3 7 - 1 4 ARPIAR TARVERDI EQUIPMENT SPECIFICATION Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 709 W Jonquil Rd, Santa Ana, CA 92706 SOLAR OPTIMUM 972228 X X X X X X X X X X LORENA HERNANDEZ 818-804-3122 09/22/25 lorenahernandez@solaroptimum.com