Loading...
HomeMy WebLinkAbout10181747_3357 S. BRISTOL - PlanPlanning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org ELECTRICAL SIGN REQUIREMENTS Code references are to the 2010 California Electrical Code (CEC) A. All signs require Planning Department approval. B. All electrical signs require electric plancheck and permit. 1. Manufacturer's instructions are required at the time of submittal. C-11: 3-21-2011 2. Submit detailed installation instructions including diagrams to the Building Department for plan review at the time of submittal. Plans must include appropriate items noted by this bulletin. 3. Cash or surety bond in the amount of $200.00 is required at time of issuance for each address. The cash or surety bond will ba refunded after all required finals. C. A building permit is also required - except for open or highlight neon lighting. D. Installation Requirements: CONTACT FIELD INSPECTOR PRIOR TO SIGN INSTALLATION. (SEE SECTION G OF THIS BULLETIN) 1. Conductors and equipment shall comply with California Electric Code Article 600. 2. All metal parts of a sign shall be bonded in the manner specified in Article 250. Isolated metal parts are permitted to be bonded by using an external green insulated conductor. Equipment grounding & bonding conductors must be sized by 110.26 and protected from physical damage. Minimum size is 14 AWG. CEC 600.7 3. A listed disconnect switch in the power supply primary, shall be installed within sight of sign or have permanently installed means for locking in an "OFF" position. This is also true for a transformer enclosure. CEC 600.6 4. A listed receptacle or an approved termination device shall be used for each neon electrode. To relieve stress at terminations, tubing shall be supported with listed tube supports in an approved manner within six inches of electrode connection. CEC 600.41 & 600.42 5. Every electric sign of any type shall be listed by an approved testing laboratory and shall be installed in conformance with this Ii;sting. That includes "1 of x", "2 of x" labeling for each separate unit of a multi-unit sign. CEC 600.3 6. All "can" letters and transformers housings shall have section labels that are readily visible after installation. CEC 600.4 7. Transformers shall be located where accessible and be securely fastened in place. Page 1 of 2 When not inside the sign, they need a 3 foot high x 3 foot wide x 3 foot deep workspace. Transformers are permitted to be located in attics or canopies provided there is a passageway at least 3 feet high x 2 feet wide With a minimum 12 inch catwalk/walkway from the point of entry. Transformers must be securely fastened and independent of T- bar when above; a suspended ceiling. No part of sign may be fed with flexible cord when located above T-bar ceilings. CEC 600.21(E&F) & 400.8 8. Adequate illumination shall be provided for all working spaces about electrical equipment. This applies to attics and canopies when entry is required to service or inspect the equipment. At least one switch is required at entrance. CEC 110.34 & 600.21 9. Doorway to an attic or canopy space shall be minimum 3 feet by 2 feet wide. CEC 600.21(E) E. Open neon outline or highlight lighting. 1. To be treated as a sign by this department. However, Section D-5 & D-6 of this bulletin will not apply. 2. Neon tubing shall be located where not normally exposed to physical damage. Open neon tubing below 9 feet shall be protected from physical damage by an approved shielding method. CEC 600.30 and 110.34(E) F. Light-Emitting Diode (LED) Signs 1. Will be treated as a sign by this department. All sign rules in sections A, B, C, D, F, and G will apply as appropriate. 2. LED illumination for signage must be a listed or recognized component. Many LED manufacturers specify particular brands and models of transformers some do not. Manufacturer information to clarify this issue is required on LED sign plans. 3. Unlisted LEDs may not be used in an electrical sign or as permanently installed illumination. 110.3 4. Please have packaging or catalog cut-sheets on hand for inspector to review when LED modules do not bear listing symbols. G. Inspections 1. Contact an Electrical Inspector one (1) workday (minimum) in advance of installation to arrange a site meeting on day of installation. 2. Call for inspection Monday through Friday, 8:00- 8:30 a.m. at (714) 647-5821. Approved prints and the job card must be on site for inspection. Page 2 of 2 --- - .50163 - *. 25 S. MAIN STREET, GARDNEA CA 90248 CS.-* 0 - :'310-769-0700 : 888-392-4931 E-MAIL: INFOSIGNINSTALLERS.ORG / EXTERIOR SIGN SITE PLAN APPROVED PREPARED FOR:PLANNING DIViSION MASTER I.D. 1,0(4 , /(41 60 . DAISO JAPAN - SANTA ANA G.P. 66 /6 A .Zork Cl 3357 S. BRISTOL ST SANTA ANA, CA 92704 PLANNER /y-72 ' DATE 6 -/7 -f ¥ #V . ARCHiTECTURAL STRUCTURAL ACCEPTED FOR CONSTRUCTSON SEPARATE PERMITS ARE REQUIRED FOR DAISO 0,"ELECTRICAL, PLUMBING & MECHANICAL PLANS This set of plans and specifications must be kept on the job JAPAN •at all times and it is unlawful to make any changes oralterations on same without written permission from the, City of Santa Ana. The acceptance of this plan and specifications SHALL NOT be held to permit nor be an approval of the violation of anyprovisions of ANY City Ordinance or State Law. , Accepted By C.!Ji Floheq CITY OF SANTA ANA Date / 2 72 4 TRANSFERRED BY -DATE - PLANNiNG INSPECTION REQUIRED:H.ONE 4ROUGHSiMAL Fj/n -(714) ri·--A R' 0-1 r. r.' c :.·r•.0 0 2-·n iRC 70 .-;'·79-kIC SUBJECT TO A-LE:S CHECKED AND CONDITIONS BELOW: U NO E;-3-1.:>:I P../.LTERATiONS,MODIFICATIONS O ALL M.-',",-Ek:.':.LS TO MATCH EXISTING ·WiRED I -9.-/ ..... I .U b:,civ:i-1- 1./.t'OSCAPE PLANSO WE- C.A.a.,ui) i eFfsr c.,·•¢gt;'6 10 .AA.\22/ 3 UOLUJ)11 ..t PROPERTY MANAGEMENT:TENANT: Brixmor Property Group Daiso California LLC 3636 Nobel Drive Suite 300 26523 Danti Court San Diego, California 92122 Hayward, California 94545 TEL: (858) 202-1125 TEL: (510) 78+0828 FAX: (858) 457-1848 FAX: (510) 784-8941 Contact:Tyler Barry Contact:Yoshihide Murata LUatlled..... CLIENT NAME:DOCUMENT#: CLIENT'S SIGNATUBEj<lk 95@32» ' PROPERTY OWNER'S SIGNATURE YOUR SIGNATURE ACKNOWLEDGES FULL APPROVAL OF DESIGN CONTENT AND LAYOUT. RELEASING METRO SIGNS FROM RESPONSIBILITY IN REGARD TO INCORRECT DESIGN AND INFORMATION, THE COLORS SHOWN ARE ONLY REPRESENTATIVE OF ACTUAL PMS COLOR CALL OUTS. FINAL DATE COLOR WILL BE MATCHED AS CLOSE AS POSSIBLE, COMMENSURATE WITH MATERIALS USED. THIS DESIGN IS PROPRIETARY PROPERTY AND MAY NOT4-<5.14)BE USED WITHOUT THE EXPRESSED WRITTEN CONSENT OF METRO DATE'SIGNS. PLEASE FAXAPPROVED PROOF TO 888-392-4931 METROSIGNS 15225 S. Main Street Gardena, CA 90248 Tel: 310-769-0700 Fax: 888-392-4931 E-MAIL: info@signinstallers.org ' S. BRISTOL ST SANTA ANA, CA 92704 Storefrontage: 71 ft 3Nn ALBadOUd r7 21,000 SF 1 AU 14 £ i 1'2 ft L.7 . 6 12 \, rr I / /19 I \ I -1 . / ,5*/ 4· %§§ Iii 13.. 57. tral .w/?R ,4-8120950 99 k.. / -/590 \ . §¥:.\\ . .. . / ill 4, 0 2 1 9,9§ . 0 \ / 0 050 \ , \ =Z \ 1.91 / \-4 4 -. ./ . -1·· ··.·.-: v ··...1 Ul «ap;.p.· . - -.) 111-1'111111111 i l i l l i l l I fffi l l 111-11-ri l i l il l l]11'11 lit' 11 1.11'111:11.11 -11.11 81*1"1111*1·k]1 8,1\\\\\bl D. 014 /V /V «44%/\/ A G\\\\\\\4\\\\04« %»%491\\\\\\\\\\\19 0= 1 1D 42Ill \\\\\\\\\\\\9 231. 5I 3"\\\\N 0 O NI ION1,rm":wri I. El 1,211 1111111110 Fl 1,1,111,111 III 1,1] 11,1 lilli.1 IER I.I I.I.I I:I I.!.I I I.I I J I I I J. I I.l !,I Il:1 f?-1 ........... : h.... U ell : PROPERTY UNE . BRISTOL STREET 71-*.j '11 1 ,1 2 9'893'•ra A : 9 5 I 14 2 2 W C/la-e Ae Wt•-hES¥» • I 11 ... i *Cum/Al ;1-,e=•MchEI: :1 4,17*41.-19 4-,£,nt.,b•,Irtier-1 ..1 1-:21[ .1 - W Ma/Artly ENd W Ma©Arthu Blvd ! 0 C*Cr, A. Sign Approval for Daiso Japan approved for General layout and design as exhibited. Brixmor GA Bristol Plaza, LP 8,>dflk >24*- Sheila Pocknett, Property Manager Date: June 5, 2014 -t Proposed Sign #1 INTERNALLY ILLUMINATED CHANNEL LETTERS:Qty: 1 set Overall Size: 6'- 51/2"H x 17'-10"W (77.50"H x 214"W) DAISO .," JAPAN * Sign Area: 115.17 Sq Ft,AYStore Frontage: 71 ft < W JOB#:CLIENT NAME:DOCUMENT#: DESIGNED DATE: SENT DATE: - DESIGNER:CLIENT'S SIGNATURE DATE REVISED DATE: SENT DATE:kmt/kiditil Y .P 0 -A.S.,4 DESIGNER:PROPERTY OWNER'S SIGNATURE DATE ' Location: 3357 S. BRISTOL ST SANTA ANA, CA 92704 INTERNALLY ILLUMINATED CHANNEL LETTERS:Qty: 1 set Overall Size: 6'- 5 1/2"H x 17'-10"W (77.50"H x 214"W) YOUR SIGNATURE ACKNOWLEDGES FULLAPPROVAL OF DESIGN CONTENT AND LAYOUT, RELEASING METRO SIGNS FROM RESPONSIBILITY IN REGARD TO INCORRECT DESIGN AND INFORMATION. THE COLORS SHOWN ARE ONLY REPRESENTATIVE OF ACTUAL PMS COLOR CALL OUTS. FINAL COLOR WILL BE MATCHED AS CLOSE AS POSSIBLE, COMMENSURATE WITH MATERIALS USED. THIS DESIGN IS PROPRIETARY PROPERTYAND MAY NOT BE USED WITHOUT THE EXPRESSED WRITTEN CONSENT OF METRO SIGNS. PLEASE FAX APPROVED PROOF TO 888-392-4931 Sign Approval for Daiso Japan approved for General layout and design as exhibited. Brixmor GA Bristol Plaza, LP METROSIGNS 15225 S. Main Street Gardena, CA 90248 Tel: 310-769-0700 Fax: 888-392-4931 E-MAIL: info@signinstallers.org By:%222 9££520 Sheila Pocknett, Property Manager Date: June 5, 2014 T.O.P. 4 25' - 4" -- - -1 /-- - 1 El-\T.Qlp.-3 , f - 4 . 3 22'-4"-- 02 -. DAISO 0,"1 T.O.P. 2 19' - 10". JAPAN • ,/ I 01 4 . 1.211 7 ililili/4/0/'I d/, 2 22 22 1-2111'I'1'I','I'1'1'11 11litillil \P/221211 I1II1III 11 1 1.1 1.1 1 1 '1 I'I'Ii'I'I'I'I 1 1 1 1 1 1 1 1 --1 !11!11 1.11\ I \# L-21 Ual 4331 A 01 I 1111,11 11/ :I'I'''I'I'IIII,1I 1 II1I,II11 11 1 / 1 lilli--EXIST. BRICK; ,I,I,1,1,1,1'I1'1 , IIIItIIII WALL BEYOND 04 1I,1II1II1 11 1.1 l il i 11. ; 1'1'I'1'1'1'1'11' [ 111111'11 1IIII111I,Level 1 0' - 0" 71 ft (STORE FRONTAGE) Sign Area: 115.17 SqFt Store Frontage: 71 ft 17'- 10" JOB#:CLIENT NAME:DOCUMENT#: DESIGNED DATE: SENT DATE: - DESIGNER:CLIENT'S SIGNATURE REVISED DATE: SENT DATE:\9LJ.. -14*03(09 DESIGNER:PROPERTY OWNER'S SIGNATURE YOUR SIGNATURE ACKNOWLEDGES FULLAPPROVAL OF DESIGN CONTENT AND LAYOUT, RELEASING METRO SIGNS FROM RESPONSIBILITY IN REGARD TO INCORRECT DESIGN AND INFORMATION. THE COLORS SHOWNI ARE ONLY REPRESENTATIVE OF ACTUAL PMS COLOR CALL OUTS. FINAL DATE COLOR WILL BE MATCHED AS CLOSE AS POSSIBLE, COMMENSURATE WITH MATERIALS USED. THIS DESIGN IS PROPRIETARY PROPERTY AND MAY NOT6 -6- 14 BE USED WITHOUT THE EXPRESSED WRITTEN CONSENT OF METRO DATE'SIGNS. PLEASE FAX APPROVED PROOF TO 888-392-4931 METRO SIGNS 15225 S. Main Street Gardena, CA 90248 Tel: 310-769-0700 Fax: 888-392-4931 E-MAIL: info@signinstallers.org .040 ALUM. RETURNS 4'LOCatiOn: 3357 S. BRISTOL ST SANTA ANA, CA 92704 with 3/16·Clear Lexan Backing. INTERNALLY ILLUMINATED CHANNEL LETTERS (SOUTH ELEVATION): -» 3/4'Trim Cap--1 ,/1-1 Qty: 1 set (Silver) . Overall Size: 6'- 5 1/2"H x 17'-10"W (77.50"H x 214"W)T:-MiN. 2"*»7RA170<J 3/8-Diam. 7-long Lag Bok Copy: FOUR SQUARE LOGOS, DAISO, JAPAN 1/8· Acrylic Face with -(Min.4 per Letters) Colo,TranslucentVinyt SQUAREs: 15"H, 17'; 23'; and 24"H DAISO (ENG): 30"H Letter 12¥W}ITE LED MODULES BORDER: 4"H x 214"W 5TUCCOWALL - LED Power SupplyJAPAN: 20"H Letter v-331/ -Disconnect Switch Face: 1/8" Acrylic with Color Translucent Vinyl Overlays 1- 4-30Return: 4"Thick, Silver,.040 Aluminum 'Wh Trim Cap: 3/4", Silver :'|-J-Box Illumination: 12V WHITE LED, FRONT & BACK COMBO LIT | |11/2'Spacers AUELECTRICAL 4 /--l.» fletters to be pegged offofwall}COMPONENTS ' ELECTRICAL NOTEE=Zi lit. ELECTRICAL PRIMARY CIRCUITS kful BE DEDICATED ISOLATED CIRCUITS PROVIDED..CLENT/OTHER. G. TO PROVEE ACCESS,liTY TO REMOTE TRANSFORMERS AND OR BALLASTS FOR INSTALLATION AND SERVICE. Sign Approval for Daiso Jagan approved for General layout and design as exhibited. APPROVED --9- TYR CHANNEL LETTER SECTION DETAIL FINU ELECTRICAL FROM BREAKER TO t¢FT NEAR SIGN AREA TOBIE PROVIDEDBYCENTRTHER SCALE: NTS Brixmor GA Bristol Plaza, LP 0,>22212, 468 Sheila Pocknett, Property Manager --matejune 5, 2014 DAISO. 24 COLOR SPECIFICATION: PINK LETTERS: 3M 3630-133 (RASPBERRY, PMS220C) DICE: 3M3630-83 (REGAL RED, PMS187C) 3M3630-57 (OLYMPIC BLUE) 3M3630-156 (VIVID GREEN, PMS 335C) 3M3630-118 (INTENSE MAGENTA„ PMS241 C) 3M3630-61 (SLATE GRAY) Sign Area: 115.17 SqFt Store Frontage: 71 ft.IAVAIN 0 15 17'- 10 FRONT LIT CHANNEL LETTER - CUT SHEET DIAGRAM S 5" Aluminum Return Aluminum Back Acrylic Face 1 Pass Through Grommet- Clinched and Caulked Seam LED Illumination- Drain Hole MIN. (21 * " pse LE77« FRONT VIEW LED Lead Wire C'Whip") 50' Aluminum Return 1" Trim Cap Pass Through Grommet Power Supply LED illumination, 1 111Ill SIDE VIEW FLUSH MOUNT UL48 41.1.1 (ej Conditions of use for components required to complete wtrtng* cIm iaecognized Componenr LED. Class 2 Illumination SystemModules Suitable for wet or dry location; Faotory Wired. (Narna of oomponent mfg.) 2. Recognized Component" Class 2 Power Supply in 24 ga sheet metal enclosure. Power supplv lactory installed in enclosure. Secure enclosure to wall swface with four (4; wall board fasteners 3. Type PLC cable* irated for use wilhout conduit in damp or dly location. Connect power supply output leads with:insulated compression wirecannectors to matching color of free oonductom in secdon letter Bundle neatly and secure to wall with piastic cable ties witEn 12" of conduit and enclosure and at 6' intervals. C.Im k § 4. Drill r dia holes thwough cement block facia, perpendicular to wall at locations shown on full size installation pattern. Secure 1/2",unning thread to metal letter back. Remove paint from metal at point of conne©0on to condul Double lock=nut, ,p,renal tight Insert 12" rning thread through holes in wail. Apply silacone sealant around conduit and hole in cement block before litting the letter back flush with wall surface. 5. Thread groundjng bushing onto 1/2* running thread ©ondwit, Attach No. 14 bonding jumper to each bushing (6>and to one Power suppgy endosure Bond enclosures 10 branch circuil equipment ground. 6. Channel letter subassembly sign body suitable for wet localion. One 1/4- drain hole in low points of each letter. Attaoh metal letter back to building lacia with 1/4" concrete fasteners at predrilled Iczations in letter back. *3* tal7. No. 14 MC Cable between power supply enclosures and disconnect. Secure to wall with cable lies, Malhin twelve (121 inches of te,mination at enclosure and at no Oess than al six fool (6) intervals 8. Safety Switch / Single Pole / Dry gocation. Firmly secure in piaoe with wallboard fastners Branch circuit conductors of suitable capacity and approvd type to section sign by others, (120 V / 20 AMP / 792 VA) tdO. *66) COPY OF MANUFACTURERS CONDmONS OF USE FOR EACH OOMPONENT ANACNED AND INCLUDED AS PART OF INSTALLA71O9 INSTRUCm©HS. Appendi©GG 321 10 40,01-'1'· . . ,$: 249: e, it'/ f '<¥-'trely 1 · 3 ·2 -,; Pip*,:„.· :'·-b t[$1 ··i'.· 29· ' '4;*P»81*,1,· - M,;1#-434;!1*€, ", 4. ,-17 ISTIEN[ill.AFTXm)ifrll<ISEiesTJME!1 14#44©vi t..7,-- ·- 7, 7 -· ' - ,--, df*10%74.·3 ..DA'76:21:, -.24 *Di>.5934 IM Model No. ECO2S-W Product Image -218737//51/lus/LO Features Optimized products for price sensitive market 3chip SMD LED mounted, CE Approved ( € High luminosity& Compactdesign Slight current drop through wire to wire connection (vs. Soldering) Max. 50 modules in series Reverse voltage, current protection Double-sided PCB design to maximize heat release 120° Viewing angle creates better silhouettes with even light distribution Durable epoxy resin fill for waterproof rating with IP68 12V DC operation requires a constant voltage Power supply (Sold separately) Product dimension and connections Case Dimension: 38L x 12W x 7H mm,Weight: 7g per module LED Pitch : 25mm, Wire length : 60mm, Center to Center : 98mm Maximum run in series: 50 modules 38 , 60 , 38 4 t=In,n- n r, ,r-1 n 1--1 ninCEI P B *-81 ,9.N 25 19.5 8.5| 25 KE 98 Product dimension and connections Product No. Color Operating Power ...... Power / Current Dissipation LED Spec Luminous intensity(mcd) Luminous intensity(Im) Dominent Wavelength Standard Color Temperature Module connection & Cuttability Recommended Channel Height Operating Temperature Storage Temperature ............................................ Waterproofing rate Cable Case Materials [ECO2S - W] w I E i ® ,< 03 1 am DC 12V 0.48 W, 40mA 120° Viewing angle, 50,000hr rated life, made in Korea 11,000 4,200 7,200 1,600 2,400 31.2 11.9 20.3 4.5 7.2 - i 625 525 460 - 8,500 --:- Wire to Wire Series connection, every module Min. 80mm -20°C- 60°C -30°C- 70°C ........................... IP68 awg18, 1007-SPT-1(105°C) ABS housing + Ductile Epoxy Treatment MC EED 1*EN: m-Head office : 4F, Daedeak B/D, 513-32 Amsa-dong, Kangdong-gu, Seoul, Korea Factory : 16-5, Kakok-Ii, Hwuado-eup, Namyangju-si, KyungKi-Do, Korea Website : www.ncled.co.kr Email to saf¢$11(@tri:cladkzLRr :r,t 0,4:.4..44'Fti;&&7:3/ 4 -11 I' --.4-17 -66 -d '-44I l'ILL'I'470*17040%01*044 996*516/ * DIAGRAM for ECO Series 2 ' C·> OciOUTPUTI 1. Maximum run : 50 pcs in series / depends on SMPS in parallel SUPE Itil :AC. UIP{fr fo 01 lo 0 i° 01 fo 01 10 OJ P 01 lo oJ 00 2. Maximum Usage of SMPS Capacitv = SMPS capacity * 0.8 (80%) ex) In case using 200W SMPS, 200W * 0.8 = 160 W for the best stability Watts of LED Modules = Number of LEDs * 0.24W ex) In case 200pcs of ECO3S-W, 200 *3* 0.24 = 144W 3. Pitch between modules : See the last page CAUTION Any actions against following contents will cause serious issues such as malfunction, electric shock or burn. I. Do not connect directly to AC 100V / 220V !. Make sure that the wire connection of INPUT (AC 100V/ 220V) & OUTPUT (DC 12V) is not switched. 1. Make sure that its polarity (+, -) is connected right. (Red lined-cable : +, White cable : -) I. Do not over the maximum connectable numbers of module. 50EA in series. 9. Do not cut wire or any kinds of wiring while modules are connected with live power source 1. Avoid installation under rain or high humidity for outdoor use. Installed LED Sign must be covered for outdoor use. Should be protected from rain and direct ray of the sun for a long term use. It can causes crack of LED lamps. For indoor use where possibly has human contacts must be covered too. '. Do not use in the circumstance of over 70% humidity 1. Do not tough LED lamps with sharp objects 9. Make holes for water drain on the down side of channel letter for outdoor use. 0. Strand of modules must be capped with wire nut, compression tube or insulating tape to protect from electric leakage. "m:218) *Ragg*q Head office : 4F, Daedeak 8/D, 513-32 Amsa-dong, Kangdong-gu, Seoul, Korea Factory : 16-5, Kakok-li, Hwuado-eup, Namyangju-si, KyungKi-Do, Korea Website : www.ncled.co.kr Email to salks/@rlded.co..k¢ A IE LED Channel Installation direction Tools & Supplies Wire Stripper, Drill, Screw Driver, Tower, Wire nuts, Nippers, Insulating tape, Compression Tube, Connection cable to power, Bushing. (Option: Slilicon and Screws) Materials * LED Modules: ECO Series Modules * Channel Letter Height : 80-120mm * Recommended cover materials: Light diffusion PC (Polycarbonate) or Acrylic exclusive for LED * Recommended paint color inside channel letter : White color for better reflection of LED lights 1. Clean the moisture,dust and oil inside the channel letter and check if there is scratch or breakage. Adhesive tape will be taken off easily in case products is mounted on dirty and uneven surfaces. 2. Using predetermined layout, place LED modules with adhesive tape on the backside of modules. Make sure that modules are firmly attached on the surface. Do not press down directly on the top of LED lamp to avoid any damages. 3. Make holes using drill, one for wiring on the backside of channel letter, another one for water drain on downside. Use bushing to protect wires from an electric leakage. 4. To fix modules permanently, spread silicon on the side of modules 5. Do wire between LED modules and power supply(SMPS) minimizing the wire length. ( Above 5meter wiring, need consulting) 6. Cap all strand of modules using wire nut or compression tube, silicon for waterproofing. 7. Power on the power supply(SMPS) and do lighting test. N 8. If lighting has no problem, cover the channel letter and check the exterior. N'10 WES•soiq Head office : 4F, Daedeak B/D, 513-32 Amsa-dong, Kangdong-gu, Seoul, Korea Factory : 16-5, Kakok-Ii, Hwuado-eup, Namyangju-si, KyungKi-Do, Korea Website : www.ncled.co.kr Email to safesi @ncred.co.* ay.» • Mvt' ' .**»92 '1 96" 0· '.©t "6.«. 2,40>49 .:94Af©43*%(·4 46>d.£, 4-4*tn ..!ft.-2..4 k-'41 304,1. A • A *,1 A -r r. It r- /*#* 0.t*J . p Jp' · · <:#4:4 :*9$$ t'I„& ete .... :d ...# . I.;I LA . 1-<.+ ./. I.·v. 2 A Ir »'.'.-I>q,· .4. P.iQ'c ..·..?47 :24< I i LED Module Diagram SMPS (DC12V) 1.4711 !1*·1 1 U.!13%LU Z= 2038221 (AC{00-2409] 11 ® LED Module Pitch + i ECO 1 ECO 23. 1 ECO 2 598+1. 3& 30 9& 30.38. 30.24 4929: L fc#.1 f.-71 G-7 'f- 1-7 .-/ ·r/=m. ·r.=.1- '45.45.45. 55 -· 55 - * g 62 62 ECO 3S - - _ EC-0 3 *_ . EGO 4 '45 . 45 45.45 -66. 34.. 66.·'134. 66.34. 66 1 1 1 66 -M . 66. 3.4 66 34 66 070 NCEED WME#.iq Head office : 4F, Daedeak 8/D, 513-32 Amsa-dong, Kangdong-gu, Seoul, Korea Factory : 16-5, Kakok-li, Hwuado-eup, Namyangju-si, KyungKi-Do, Korea Website : www.ncled.co.kr Email to sal*51 @n¢fed.co.f« SIGN COMPONENTS MANUAL (SAM)October 1, 2013 11. This material has not been investigated for the securement of conduit, electrode housings or the like, suitability shall be determined in the end product. NANJING CEDAR GREEN TECHNOLOGIES CO LTD 739 SHENGAN AVENUEY BINJIANG DEVELOPMENT AREA JIANGNING DISTRICT E358556 NANJING, JIANGSU CHINA Class 2 LED modules, Cat. No. CD-MXX-XXX-XX-XX-XXX series. The first X can be any one of the Arabic numerals of 1 through 9, these indicate LED quantity; The second X can be any letter in alphabet, represent for beam angel; The third X is for the supplier of the lamp; The fourth X is for the model of the lamp; The fifth X can be any one of alphanumeric characters; The sixth and seventh X is for the color; The eighth and ninth X is for the product versions; The last three X are for the input voltage, 12V represent the input voltage is 12VDC, 15V represent the input voltage is 15VDC. 1. These products are only suitable for connection to a Class 2 power source, rated 15 Volt DC or less. (For model CD- MXX-XXX- XX-XX-15V) 2. These products are only suitable for connection to a Class 2 power source, rated 12 Volt DC or less. (For model CD- MXX-XXX- XX-XX-12V) 3. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limits and which is rated greater than electrical ratings. 4. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 5. These products are suitable for use in dry, damp and wet locations with supply sources rated at 15 Vdc or less. (For model CD- MXX-)O(X-XX-XX-15V) 6. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Vdc or less. (For model'CD- MXX-XXX-XX-)O<-12V) 7. These products are not required to be enclosed or protected from the weather in the end product. 8. The suitability of supply leads shall be determined in end use. NANOLUMENSINC 4900 AVALON RIDGE PKY NORCROSS, GA 30071 Component Signs, Models NS-400, NS-500, NS-521, NS-600, NS-625, NS-1000. 1. These components should be installed in accordance with the manufacturer's installation instructions. 2. These products are suitable for use in dry locations. 3. Each power supply can only drive max number of 15 modules. 4. These units are rated as follows; E348993 Input Output Per Power Supply Input Voltage : Max. Input Current Input Frequency Output Voltage Max. Output Current Model Designation (Vac) (A) (Hz)(Vdc) (A) < NS-400, NS-500, NS-521,120-240 -5-2.5 50/60 5 60 1 NS-600, NS-625, NS- 1000 5. These products shall be enclosed in a suitable electric enclosure in the end product. 6. When provided with attachment plug, this product shall be connected to a dedicated receptacle in a permanently connected sign. 7. These products are suitable for factory installation only. NC LED CO LTD 16-17 GAGOK-RI HWADO-EUP E347462 NAMYANGJU-SI, GYEONGGI-DO 472-841 REPUBLIC OF KOREA Sign Accessories, Class 2 LED Modules: HLC1, HLC2S, HLC2, HLC3S, HLC3, HLC4, OMX-L4, OMX-L3, OMX-M3, OMX-M2, OMX-S2, OMX-Nl, CC-IF'-04, CC-IP-03L, CC-IP-03, CC-IF)-02L, CC-IP-02, CC-IP-01, ELW4, ELW3L, ELW3, ELW2L, Elm, ELW1, CCL4S, CCL3L, CCL3, CCL2L, CCL2, CCL1, L)<-HLC4, LX-HLC3S, ID<-HLC2S, EC01, ECO2S, EC02, ECO3S, EC03, ECC)4, EC-IP-04, EC-IF'-03L, EC-IP-03, EC-IP-02L, EC-IP-02, EC-IP-01, eco max OM)<-L4, eco max OMX-L3, eco max OMX-M3, eco max OM)<-M2, eco max OM)<-S2, eco max OMX-Nl, LX-ECO4, LX-ECO3S, LX-ECO2S, NCP1, NCP2S, NCP2, NCP3S, NCP), NCP4, CCL4, NCO, NCC3S, NCC2, NCC2S, NCCI, LX-HLC4, LX-HLC3S, LX-HLC2S, LX-EC04, LX-EC03S, LX- ECO2S, MIN13, RGB3, RGB4, LX-RGB3, LX-RGB4. 1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less. 2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy limited circuit and is rated greater than 12V DC. 3. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. These products may be secured in place in the end product by any means. NEO-NEON LED LIGHTING INTERNATIONAL LTD BLK B, 12th FL E252578 rl 4- 27- I q 333-7 LS 34 3-4/ --:44 *rGRADING 58 A,hi Mjl i I -117 37 '4:.1 .../ 4,0..3 - --V-366 YES19/CT it -*#,90 7 r ---38 :.%. .1 it«I 44