HomeMy WebLinkAbout1 E MacArthur Pl Unit 800 - Plumbing Only - PlanPLUMBING COVER SHEET P-1.1 Electrical Mechanical Plumbing 333 City Blvd. West, Suite 300 Orange CA 92826 office fax (714) 449-1646 (714) 449-1946 Consulting Engineers 3042.08Project Number: Sheet Number Sheet Title PRINT DATE DATE CHECKED DRAWN cad 10.07.24 Sorin A. Brie REVISIONS DESCRIPTION DATE USABLE: PROJECT TENANT SQUARE FOOTAGE 23,000 U.S.F. INTERIOR PLANNING & DESIGN P&D INC. 3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626 949.724.1499 / www.spaces-oc.com EIGHTH FLOOR Ma c A r t h u r P l a c e 1 M a c A r t h u r P l a c e Sa n t a A n a , C A 9 2 7 0 7 NEW AMERICAN FUNDING WITH ELEVATOR LOBBY AND REST ROOMS SUITE 800/8TH FLR 1 M a c A r t h u r P l . , S u i t e 8 0 0 ( N e w A m e r i c a n F u n d i n g ) , S a n t a A n a C A 1 M a c A r t h u r P l . , S u i t e 8 0 0 ( N e w A m e r i c a n F u n d i n g ) , S a n t a A n a C A LEGENDPLUMBING FIXTURE SCHEDULEPLUMBING NOTES SHEET INDEX PIPE MATERIAL SCHEDULE · · · · · · · · · · · · SCOPE OF WORK · · · · · · · · PLUMBING FIXTURE SCHEDULE GENERAL NOTES · · \\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\08\Suite 800 (New American Funding)\1 MacArthur Pl., Suite 800 (New American Funding) P-1 Plumbing Cover Sheet.dwg, 7/2/2025 3:43:00 PM PLUMBING DETAILS P-1.2 Electrical Mechanical Plumbing 333 City Blvd. West, Suite 300 Orange CA 92826 office fax (714) 449-1646 (714) 449-1946 Consulting Engineers 3042.08Project Number: Sheet Number Sheet Title PRINT DATE DATE CHECKED DRAWN cad 10.07.24 Sorin A. Brie REVISIONS DESCRIPTION DATE USABLE: PROJECT TENANT SQUARE FOOTAGE 23,000 U.S.F. INTERIOR PLANNING & DESIGN P&D INC. 3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626 949.724.1499 / www.spaces-oc.com EIGHTH FLOOR Ma c A r t h u r P l a c e 1 M a c A r t h u r P l a c e Sa n t a A n a , C A 9 2 7 0 7 NEW AMERICAN FUNDING WITH ELEVATOR LOBBY AND REST ROOMS SUITE 800/8TH FLR 1 M a c A r t h u r P l . , S u i t e 8 0 0 ( N e w A m e r i c a n F u n d i n g ) , S a n t a A n a C A 1 M a c A r t h u r P l . , S u i t e 8 0 0 ( N e w A m e r i c a n F u n d i n g ) , S a n t a A n a C A SCHEDULE FOR SINGLE PIPE HANGERS 3/4" THRU 6" PIPE SUPPORT SPACING SCHEDULE 2 INSTA-HOT INSTALLATION DETAIL TYPICAL COUNTER DETAIL 1 4TYPICAL FIRESTOP PENETRATION DETAIL 3 1. WALL ASSEMBLY -- THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300, U400 OR V400 SERIES WALL AND PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS -- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED MAX 16 IN. (406 MM) OC. STEEL STUDS TO BE MIN 3-1/2 IN. (89 MM) DEEP, FABRICATED FROM 25 MSG GALV STEEL, SPACED MAX 24 IN. (610 MM) OC. B. GYPSUM BOARD* -- THE GYPSUM BOARD TYPE, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM OPENING IS 12 IN. (305 MM). THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. 2. THROUGH PENETRANT -- ONE METALLIC PIPE, CONDUIT OR TUBE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE MIN ANNULAR SPACE BETWEEN THE PIPE, CONDUIT OR TUBE AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 7-7/8 IN. (200 MM). PIPE CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBES MAY BE USED: A. STEEL PIPE -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. B. IRON PIPE -- NOM 4IN. (102 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. CONDUIT -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT. D. CONDUIT -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC CONDUIT. E. COPPER TUBING -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. F. COPPER PIPE -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. 3. FIRESTOP SYSTEM -- THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. PACKING MATERIAL -- GLASS FIBER OR MINERAL WOOL BATT INSULATION FIRMLY PACKED WITHIN THE WALL CAVITY AROUND THE OPENING AS A PERMANENT FORM. B. FILL, VOID OR CAVITY MATERIAL*-FOAM -- FILL MATERIAL APPLIED WITHIN ANNULUS FLUSH WITH BOTH SURFACES OF THE WALL. MIN FILL MATERIAL THICKNESS FOR 1 HR F RATING IS 4-3/4 IN. (121 MM). MIN FILL MATERIAL THICKNESS FOR 2 HR F RATING IS 6 IN. (152 MM). HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP 620 FIRE FOAM *BEARING THE UL CLASSIFICATION MARK Hilti Firestop Systems A A SECTION A-A WL 1 2 8 9 System No. W-L-1289 F Ratings -- 1 and 2 Hr (See Items 1 and 3) T Rating -- 0 Hr L-RA TING AT AMBIENT = LESS THAN 1 CFM / SQ FT L Rating at Ambient -- Less Than 1 CFM/sq ft L Rating at 400 F -- Less Than 1 CFM/sq ft UL 1479 and CAN/ULC-S115 52-HOUR SLAB PENETRATION DETAIL A A F RATING - 2 HR T RATING - 2 HR ANSI / UL1479 (ASTM E814) - 2 HR - 0 HR - 2 HR - 0 HR F RATING FT RATING FH RATING FTH RATING CAN / ULC S115 1. Wall Assembly -- The 1 or 2 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300, U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs -- Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced max 16 in. (406 mm) OC. Steel studs to be min 3-1/2 in. (89 mm) deep, fabricated from 25 MSG galv steel, spaced max 24 in. (610 mm) OC. B. Gypsum Board* -- The gypsum board type, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam opening is 12 in. (305 mm). The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrant -- One metallic pipe, conduit or tube to be installed either concentrically or eccentrically within the firestop system. The min annular space between the pipe, conduit or tube and the periphery of the opening shall be min 0 in. (point contact) to max 7-7/8 in. (200 mm). Pipe conduit or tube to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubes may be used: A. Steel Pipe -- Nom 4 in. (102 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe -- Nom 4in. (102 mm) diam (or smaller) cast or ductile iron pipe. C. Conduit -- Nom 4 in. (102 mm) diam (or smaller) rigid steel conduit. D. Conduit -- Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic conduit. E. Copper Tubing -- Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tubing. F. Copper Pipe -- Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe. 3. Firestop System -- The firestop system shall consist of the following: A. Packing Material -- Glass fiber or mineral wool batt insulation firmly packed within the wall cavity around the opening as a permanent form. B. Fill, Void or Cavity Material*-Foam -- Fill material applied within annulus flush with both surfaces of the wall. Min fill material thickness for 1 hr F Rating is 4-3/4 in. (121 mm). Min fill material thickness for 2 hr F Rating is 6 in. (152 mm). HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP 620 Fire Foam *Bearing the UL Classification Mark System No. F-A-1014 FA 1 0 1 4 Hilti Firestop Systems HOT WATER PIPING INSULATION DETAIL 6 FIXED AIR GAP 7 PIPE SUPPORT INSTALLATION DETAIL DISHWASHER HOOK-UP 8 WALL CLEANOUT 9 ELECTRONIC TRAP PRIMER 10 \\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\08\Suite 800 (New American Funding)\1 MacArthur Pl., Suite 800 (New American Funding) P-1 Plumbing Cover Sheet.dwg, 7/2/2025 3:43:04 PM PLUMBING TITLE 24 CALCULATIONS P-1.3 Electrical Mechanical Plumbing 333 City Blvd. West, Suite 300 Orange CA 92826 office fax (714) 449-1646 (714) 449-1946 Consulting Engineers 3042.08Project Number: Sheet Number Sheet Title PRINT DATE DATE CHECKED DRAWN cad 10.07.24 Sorin A. Brie REVISIONS DESCRIPTION DATE USABLE: PROJECT TENANT SQUARE FOOTAGE 23,000 U.S.F. INTERIOR PLANNING & DESIGN P&D INC. 3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626 949.724.1499 / www.spaces-oc.com EIGHTH FLOOR Ma c A r t h u r P l a c e 1 M a c A r t h u r P l a c e Sa n t a A n a , C A 9 2 7 0 7 NEW AMERICAN FUNDING WITH ELEVATOR LOBBY AND REST ROOMS SUITE 800/8TH FLR 1 M a c A r t h u r P l . , S u i t e 8 0 0 ( N e w A m e r i c a n F u n d i n g ) , S a n t a A n a C A 1 M a c A r t h u r P l . , S u i t e 8 0 0 ( N e w A m e r i c a n F u n d i n g ) , S a n t a A n a C A Fariborz Mozhgani Engineered Spaces Inc. 333 City Blvd., West, Suite 300 Orange CA 92868 2024-09-18 M-33211 (714) 449-1646 2024-09-18 333 City Blvd., West, Suite 300 Orange CA 92868 (714) 449-1646 \\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\08\Suite 800 (New American Funding)\1 MacArthur Pl., Suite 800 (New American Funding) P-1 Plumbing Cover Sheet.dwg, 7/2/2025 3:43:07 PM 8TH FLOOR N WOOD LOCK FE N FE N FE N FE N FE N PROJECT NORTH AREA OF PERMIT PLUMBING PLAN P-2 Electrical Mechanical Plumbing 333 City Blvd. West, Suite 300 Orange CA 92826 office fax (714) 449-1646 (714) 449-1946 Consulting Engineers 3042.08Project Number: Sheet Number Sheet Title PRINT DATE DATE CHECKED DRAWN cad 10.07.24 Sorin A. Brie REVISIONS DESCRIPTION DATE USABLE: PROJECT TENANT SQUARE FOOTAGE 23,000 U.S.F. INTERIOR PLANNING & DESIGN P&D INC. 3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626 949.724.1499 / www.spaces-oc.com EIGHTH FLOOR Ma c A r t h u r P l a c e 1 M a c A r t h u r P l a c e Sa n t a A n a , C A 9 2 7 0 7 NEW AMERICAN FUNDING WITH ELEVATOR LOBBY AND REST ROOMS SUITE 800/8TH FLR 1 M a c A r t h u r P l . , S u i t e 8 0 0 ( N e w A m e r i c a n F u n d i n g ) , S a n t a A n a C A 1 M a c A r t h u r P l . , S u i t e 8 0 0 ( N e w A m e r i c a n F u n d i n g ) , S a n t a A n a C A LIVE LOADS 2 LIVE LOADS 3 LIVE LOADS 4 PLUMBIN CONSTRUCTION PLAN 1 PLUMBING PLAN NOTES · · · · LINE ITEM: \\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\08\Suite 800 (New American Funding)\1 MacArthur Pl., Suite 800 (New American Funding) P-2 Plumbing Plan.dwg, 7/2/2025 3:43:23 PM PLUMBING SPECIFICATIONS P-3 Electrical Mechanical Plumbing 333 City Blvd. West, Suite 300 Orange CA 92826 office fax (714) 449-1646 (714) 449-1946 Consulting Engineers 3042.08Project Number: Sheet Number Sheet Title PRINT DATE DATE CHECKED DRAWN cad 10.07.24 Sorin A. Brie REVISIONS DESCRIPTION DATE USABLE: PROJECT TENANT SQUARE FOOTAGE 23,000 U.S.F. INTERIOR PLANNING & DESIGN P&D INC. 3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626 949.724.1499 / www.spaces-oc.com EIGHTH FLOOR Ma c A r t h u r P l a c e 1 M a c A r t h u r P l a c e Sa n t a A n a , C A 9 2 7 0 7 NEW AMERICAN FUNDING WITH ELEVATOR LOBBY AND REST ROOMS SUITE 800/8TH FLR 1 M a c A r t h u r P l . , S u i t e 8 0 0 ( N e w A m e r i c a n F u n d i n g ) , S a n t a A n a C A 1 M a c A r t h u r P l . , S u i t e 8 0 0 ( N e w A m e r i c a n F u n d i n g ) , S a n t a A n a C A \\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\08\Suite 800 (New American Funding)\1 MacArthur Pl., Suite 800 (New American Funding) P-3 Plumbing Specifications.dwg, 7/2/2025 3:43:29 PM