HomeMy WebLinkAbout1 E MacArthur Pl Unit 800 - Plumbing Only - PlanPLUMBING
COVER
SHEET
P-1.1
Electrical Mechanical Plumbing
333 City Blvd. West, Suite 300
Orange CA 92826
office
fax
(714) 449-1646
(714) 449-1946
Consulting Engineers
3042.08Project Number:
Sheet Number
Sheet Title
PRINT DATE
DATE
CHECKED
DRAWN
cad
10.07.24
Sorin A. Brie
REVISIONS
DESCRIPTION DATE
USABLE:
PROJECT
TENANT
SQUARE FOOTAGE
23,000 U.S.F.
INTERIOR PLANNING &
DESIGN
P&D INC.
3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626
949.724.1499 / www.spaces-oc.com
EIGHTH
FLOOR
Ma
c
A
r
t
h
u
r
P
l
a
c
e
1
M
a
c
A
r
t
h
u
r
P
l
a
c
e
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
7
NEW
AMERICAN
FUNDING
WITH ELEVATOR LOBBY
AND REST ROOMS
SUITE 800/8TH FLR
1
M
a
c
A
r
t
h
u
r
P
l
.
,
S
u
i
t
e
8
0
0
(
N
e
w
A
m
e
r
i
c
a
n
F
u
n
d
i
n
g
)
,
S
a
n
t
a
A
n
a
C
A
1
M
a
c
A
r
t
h
u
r
P
l
.
,
S
u
i
t
e
8
0
0
(
N
e
w
A
m
e
r
i
c
a
n
F
u
n
d
i
n
g
)
,
S
a
n
t
a
A
n
a
C
A
LEGENDPLUMBING FIXTURE SCHEDULEPLUMBING NOTES
SHEET INDEX
PIPE MATERIAL SCHEDULE
·
·
·
·
·
·
·
·
·
·
·
·
SCOPE OF WORK
·
·
·
·
·
·
·
·
PLUMBING FIXTURE SCHEDULE
GENERAL NOTES
·
·
\\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\08\Suite 800 (New American Funding)\1 MacArthur Pl., Suite 800 (New American Funding) P-1 Plumbing Cover Sheet.dwg, 7/2/2025 3:43:00 PM
PLUMBING
DETAILS
P-1.2
Electrical Mechanical Plumbing
333 City Blvd. West, Suite 300
Orange CA 92826
office
fax
(714) 449-1646
(714) 449-1946
Consulting Engineers
3042.08Project Number:
Sheet Number
Sheet Title
PRINT DATE
DATE
CHECKED
DRAWN
cad
10.07.24
Sorin A. Brie
REVISIONS
DESCRIPTION DATE
USABLE:
PROJECT
TENANT
SQUARE FOOTAGE
23,000 U.S.F.
INTERIOR PLANNING &
DESIGN
P&D INC.
3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626
949.724.1499 / www.spaces-oc.com
EIGHTH
FLOOR
Ma
c
A
r
t
h
u
r
P
l
a
c
e
1
M
a
c
A
r
t
h
u
r
P
l
a
c
e
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
7
NEW
AMERICAN
FUNDING
WITH ELEVATOR LOBBY
AND REST ROOMS
SUITE 800/8TH FLR
1
M
a
c
A
r
t
h
u
r
P
l
.
,
S
u
i
t
e
8
0
0
(
N
e
w
A
m
e
r
i
c
a
n
F
u
n
d
i
n
g
)
,
S
a
n
t
a
A
n
a
C
A
1
M
a
c
A
r
t
h
u
r
P
l
.
,
S
u
i
t
e
8
0
0
(
N
e
w
A
m
e
r
i
c
a
n
F
u
n
d
i
n
g
)
,
S
a
n
t
a
A
n
a
C
A
SCHEDULE FOR SINGLE PIPE HANGERS 3/4" THRU 6"
PIPE SUPPORT SPACING SCHEDULE
2
INSTA-HOT INSTALLATION DETAIL
TYPICAL COUNTER DETAIL 1
4TYPICAL FIRESTOP PENETRATION DETAIL
3
1. WALL ASSEMBLY -- THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER
DESCRIBED IN THE INDIVIDUAL U300, U400 OR V400 SERIES WALL AND PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE
FOLLOWING CONSTRUCTION FEATURES:
A. STUDS -- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM)
LUMBER SPACED MAX 16 IN. (406 MM) OC. STEEL STUDS TO BE MIN 3-1/2 IN. (89 MM) DEEP, FABRICATED FROM 25 MSG GALV STEEL, SPACED MAX 24 IN. (610
MM) OC.
B. GYPSUM BOARD* -- THE GYPSUM BOARD TYPE, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL
WALL AND PARTITION DESIGN. MAX DIAM OPENING IS 12 IN. (305 MM).
THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED.
2. THROUGH PENETRANT -- ONE METALLIC PIPE, CONDUIT OR TUBE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP
SYSTEM. THE MIN ANNULAR SPACE BETWEEN THE PIPE, CONDUIT OR TUBE AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO
MAX 7-7/8 IN. (200 MM). PIPE CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF
METALLIC PIPES, CONDUITS OR TUBES MAY BE USED:
A. STEEL PIPE -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.
B. IRON PIPE -- NOM 4IN. (102 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
C. CONDUIT -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT.
D. CONDUIT -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC CONDUIT.
E. COPPER TUBING -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING.
F. COPPER PIPE -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
3. FIRESTOP SYSTEM -- THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING:
A. PACKING MATERIAL -- GLASS FIBER OR MINERAL WOOL BATT INSULATION FIRMLY PACKED WITHIN THE WALL CAVITY AROUND THE OPENING AS A
PERMANENT FORM.
B. FILL, VOID OR CAVITY MATERIAL*-FOAM -- FILL MATERIAL APPLIED WITHIN ANNULUS FLUSH WITH BOTH SURFACES OF THE WALL. MIN FILL MATERIAL
THICKNESS FOR 1 HR F RATING IS 4-3/4 IN. (121 MM). MIN FILL MATERIAL THICKNESS FOR 2 HR F RATING IS 6 IN. (152 MM).
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP 620 FIRE FOAM
*BEARING THE UL CLASSIFICATION MARK
Hilti Firestop Systems
A
A SECTION A-A
WL
1
2
8
9
System No. W-L-1289
F Ratings -- 1 and 2 Hr (See Items 1 and 3)
T Rating -- 0 Hr
L-RA TING AT AMBIENT = LESS THAN 1 CFM / SQ FT
L Rating at Ambient -- Less Than 1 CFM/sq ft
L Rating at 400 F -- Less Than 1 CFM/sq ft
UL 1479 and CAN/ULC-S115
52-HOUR SLAB PENETRATION DETAIL
A
A
F RATING - 2 HR
T RATING - 2 HR
ANSI / UL1479 (ASTM E814)
- 2 HR
- 0 HR
- 2 HR
- 0 HR
F RATING
FT RATING
FH RATING
FTH RATING
CAN / ULC S115
1. Wall Assembly -- The 1 or 2 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described
in the individual U300, U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following
construction features:
A. Studs -- Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51
by 102 mm) lumber spaced max 16 in. (406 mm) OC. Steel studs to be min 3-1/2 in. (89 mm) deep, fabricated from 25 MSG galv steel,
spaced max 24 in. (610 mm) OC.
B. Gypsum Board* -- The gypsum board type, number of layers, fastener type and sheet orientation shall be as specified in the
individual Wall and Partition Design. Max diam opening is 12 in. (305 mm). The hourly F Rating of the firestop system is equal to the
hourly fire rating of the wall assembly in which it is installed.
2. Through Penetrant -- One metallic pipe, conduit or tube to be installed either concentrically or eccentrically within the firestop system. The
min annular space between the pipe, conduit or tube and the periphery of the opening shall be min 0 in. (point contact) to max 7-7/8 in. (200
mm). Pipe conduit or tube to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or
tubes may be used:
A. Steel Pipe -- Nom 4 in. (102 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Iron Pipe -- Nom 4in. (102 mm) diam (or smaller) cast or ductile iron pipe.
C. Conduit -- Nom 4 in. (102 mm) diam (or smaller) rigid steel conduit.
D. Conduit -- Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic conduit.
E. Copper Tubing -- Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tubing.
F. Copper Pipe -- Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe.
3. Firestop System -- The firestop system shall consist of the following:
A. Packing Material -- Glass fiber or mineral wool batt insulation firmly packed within the wall cavity around the opening as a
permanent form.
B. Fill, Void or Cavity Material*-Foam -- Fill material applied within annulus flush with both surfaces of the wall. Min fill material
thickness for 1 hr F Rating is 4-3/4 in. (121 mm). Min fill material thickness for 2 hr F Rating is 6 in. (152 mm).
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP 620 Fire Foam
*Bearing the UL Classification Mark
System No. F-A-1014
FA
1
0
1
4
Hilti Firestop Systems
HOT WATER PIPING INSULATION DETAIL 6
FIXED AIR GAP 7
PIPE SUPPORT INSTALLATION DETAIL
DISHWASHER HOOK-UP 8
WALL CLEANOUT 9
ELECTRONIC TRAP PRIMER 10
\\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\08\Suite 800 (New American Funding)\1 MacArthur Pl., Suite 800 (New American Funding) P-1 Plumbing Cover Sheet.dwg, 7/2/2025 3:43:04 PM
PLUMBING
TITLE 24
CALCULATIONS
P-1.3
Electrical Mechanical Plumbing
333 City Blvd. West, Suite 300
Orange CA 92826
office
fax
(714) 449-1646
(714) 449-1946
Consulting Engineers
3042.08Project Number:
Sheet Number
Sheet Title
PRINT DATE
DATE
CHECKED
DRAWN
cad
10.07.24
Sorin A. Brie
REVISIONS
DESCRIPTION DATE
USABLE:
PROJECT
TENANT
SQUARE FOOTAGE
23,000 U.S.F.
INTERIOR PLANNING &
DESIGN
P&D INC.
3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626
949.724.1499 / www.spaces-oc.com
EIGHTH
FLOOR
Ma
c
A
r
t
h
u
r
P
l
a
c
e
1
M
a
c
A
r
t
h
u
r
P
l
a
c
e
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
7
NEW
AMERICAN
FUNDING
WITH ELEVATOR LOBBY
AND REST ROOMS
SUITE 800/8TH FLR
1
M
a
c
A
r
t
h
u
r
P
l
.
,
S
u
i
t
e
8
0
0
(
N
e
w
A
m
e
r
i
c
a
n
F
u
n
d
i
n
g
)
,
S
a
n
t
a
A
n
a
C
A
1
M
a
c
A
r
t
h
u
r
P
l
.
,
S
u
i
t
e
8
0
0
(
N
e
w
A
m
e
r
i
c
a
n
F
u
n
d
i
n
g
)
,
S
a
n
t
a
A
n
a
C
A
Fariborz Mozhgani
Engineered Spaces Inc.
333 City Blvd., West, Suite 300
Orange CA 92868
2024-09-18
M-33211
(714) 449-1646
2024-09-18
333 City Blvd., West, Suite 300
Orange CA 92868 (714) 449-1646
\\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\08\Suite 800 (New American Funding)\1 MacArthur Pl., Suite 800 (New American Funding) P-1 Plumbing Cover Sheet.dwg, 7/2/2025 3:43:07 PM
8TH FLOOR
N
WOOD
LOCK
FE
N
FE
N
FE
N
FE
N
FE
N
PROJECT
NORTH AREA OF PERMIT
PLUMBING
PLAN
P-2
Electrical Mechanical Plumbing
333 City Blvd. West, Suite 300
Orange CA 92826
office
fax
(714) 449-1646
(714) 449-1946
Consulting Engineers
3042.08Project Number:
Sheet Number
Sheet Title
PRINT DATE
DATE
CHECKED
DRAWN
cad
10.07.24
Sorin A. Brie
REVISIONS
DESCRIPTION DATE
USABLE:
PROJECT
TENANT
SQUARE FOOTAGE
23,000 U.S.F.
INTERIOR PLANNING &
DESIGN
P&D INC.
3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626
949.724.1499 / www.spaces-oc.com
EIGHTH
FLOOR
Ma
c
A
r
t
h
u
r
P
l
a
c
e
1
M
a
c
A
r
t
h
u
r
P
l
a
c
e
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
7
NEW
AMERICAN
FUNDING
WITH ELEVATOR LOBBY
AND REST ROOMS
SUITE 800/8TH FLR
1
M
a
c
A
r
t
h
u
r
P
l
.
,
S
u
i
t
e
8
0
0
(
N
e
w
A
m
e
r
i
c
a
n
F
u
n
d
i
n
g
)
,
S
a
n
t
a
A
n
a
C
A
1
M
a
c
A
r
t
h
u
r
P
l
.
,
S
u
i
t
e
8
0
0
(
N
e
w
A
m
e
r
i
c
a
n
F
u
n
d
i
n
g
)
,
S
a
n
t
a
A
n
a
C
A
LIVE LOADS 2 LIVE LOADS 3 LIVE LOADS 4
PLUMBIN CONSTRUCTION PLAN 1
PLUMBING PLAN NOTES
·
·
·
·
LINE ITEM:
\\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\08\Suite 800 (New American Funding)\1 MacArthur Pl., Suite 800 (New American Funding) P-2 Plumbing Plan.dwg, 7/2/2025 3:43:23 PM
PLUMBING
SPECIFICATIONS
P-3
Electrical Mechanical Plumbing
333 City Blvd. West, Suite 300
Orange CA 92826
office
fax
(714) 449-1646
(714) 449-1946
Consulting Engineers
3042.08Project Number:
Sheet Number
Sheet Title
PRINT DATE
DATE
CHECKED
DRAWN
cad
10.07.24
Sorin A. Brie
REVISIONS
DESCRIPTION DATE
USABLE:
PROJECT
TENANT
SQUARE FOOTAGE
23,000 U.S.F.
INTERIOR PLANNING &
DESIGN
P&D INC.
3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626
949.724.1499 / www.spaces-oc.com
EIGHTH
FLOOR
Ma
c
A
r
t
h
u
r
P
l
a
c
e
1
M
a
c
A
r
t
h
u
r
P
l
a
c
e
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
7
NEW
AMERICAN
FUNDING
WITH ELEVATOR LOBBY
AND REST ROOMS
SUITE 800/8TH FLR
1
M
a
c
A
r
t
h
u
r
P
l
.
,
S
u
i
t
e
8
0
0
(
N
e
w
A
m
e
r
i
c
a
n
F
u
n
d
i
n
g
)
,
S
a
n
t
a
A
n
a
C
A
1
M
a
c
A
r
t
h
u
r
P
l
.
,
S
u
i
t
e
8
0
0
(
N
e
w
A
m
e
r
i
c
a
n
F
u
n
d
i
n
g
)
,
S
a
n
t
a
A
n
a
C
A
\\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\08\Suite 800 (New American Funding)\1 MacArthur Pl., Suite 800 (New American Funding) P-3 Plumbing Specifications.dwg, 7/2/2025 3:43:29 PM