Loading...
HomeMy WebLinkAbout1330 E Seventeenth-Roof Screening - PlanSANTA ANA, CA 2025 RTU SCREENING PROJECT VICINITY MAP LOCATION MAP ARCHITECTURAL: PROJECT TEAM SCOTT KLOPFER 1220 MARSHALL STREET NE MINNEAPOLIS, MN 55413 (612)677-7133 scott.klopfer@rsparch.com MATTHEW FLANSBURG 1000 NICOLLET MALL TPN-1384 MINNEAPOLIS, MN 55403 (612)761-6788 matthew.flansburg@target.com TARGET CONTACT: REMODEL SCOPE OF WORK ROOF:SCOPE OF WORK INCLUDE INSTALLATION OF RTU MOUNTED SCREENS ON EXISTING RTUS. A. NO ASBESTOS AND NO ASBESTOS-BEARING MATERIALS ARE ALLOWED ON THIS PROJECT THE EXISTING OCCUPANCY, USE, LIFE SAFETY AND EGRESS ARE NOT IMPACTED BY THE COMPLETED WORK. B. EXISTING BUILDING IS FULLY SPRINKLERED. C. SITE ZONING REMODEL BUILDING CODE INFO C-4 PLANNED SHOPPING CENTER DEVELOPMENT FIRE ZONE OR DISTRICT N/A SEISMIC DESIGN CATEGORY DESIGN CATEGORY 'D' BUILDING OCCUPANCY CLASSIFICATION M - MERCANTILE BUILDING CONSTRUCTION TYPE TYPE III-B W/4-60' YARDS TO BE MAINTAINED BUILDING ALLOWABLE FLOOR AREA UNLIMITED - FULLY SPRINKLERED ACTUAL BUILDING AREA: 115,993 SF AFFECTED AREA OF WORK: 925 SF BUILDING ALLOWABLE HEIGHT ALLOWED: 2 STORIES: 40' MAXIMUM ACTUAL: 1 STORY 26'-6" ACTUAL - EXISTING BUILDING CODE CURRENT: 2022 CALIFORNIA BUILDING CODE W/ LOCAL AMENDMENTS 2022 CALIFORNIA EXISTING BUILDING CODE 2001 W/ LOCAL AMENDMENTS 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE W/ LOCAL AMENDMENTS (CALGREEN) LOCAL JURISDICTION CODE CURRENT: CITY OF SANTA ANA MUNICIPAL CODE ACCESSIBILITY CODE CURRENT: 2022 CALIFORNIA BUILDING CODE 11B W/ LOCAL AMENDMENTS MECHANICAL CODE ORIGINAL: CALIFORNIA MECHANICAL CODE, 1998 EDITION (98 CMC) UNIFORM MECHANICAL CODE, 1997 EDITION (97 UMC) CURRENT: 2022 CALIFORNIA MECHANICAL CODE W/ LOCAL AMENDMENTS PLUMBING CODE CURRENT: 2022 CALIFORNIA PLUMBING CODE W/ LOCAL AMENDMENTS FIRE / LIFE SAFETY CODE CURRENT: 2022 CALIFORNIA FIRE CODE W/ LOCAL AMENDMENTS ELECTRICAL CODE CURRENT: 2022 CALIFORNIA ELECTRICAL CODE W/ LOCAL AMENDMENTS ENERGY / GAS CURRENT: 2022 CALIFORNIA ENERGY CODE W/ LOCAL AMENDMENTS HEALTH / FOOD SERVICE ORIGINAL: ORANGE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT CURRENT: COUNTY OF ORANGE HEALTH CARE AGENCY: CONSTRUCTION GUIDE - RETAIL (R 01/15) COUNTY OF ORANGE HEALTH CARE AGENCY: CONSTRUCTION GUIDE - PREPACKAGED RETAIL (R 06/09) NO ASBESTOS AND NO ASBESTOS-BEARING MATERIALS ARE ALLOWED ON THIS PROJECT NORTH SHEET INDEX SHEET # SHEET NAME 00_GENERAL G001 COVER SHEET 40_ARCHITECTURAL A141 ROOF PLAN & DETAILS A142 RTU SCREENS A143 ROOF PLAN SIGHTLINES R 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 Drawn By Checked By Project Number DATE: 08/04/2025 SCOTT M. KLOPFER EXP. DATE: 02/28/2027 REG. NO. C38207 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 RSP Architects, Ltd. rsparch.com Config: XX 8/4/2025 1:55:03 PM SA N T A A N A , C A 13 3 0 E A S T 1 7 T H S T . SA N T A A N A , C A 9 2 7 0 5 G001 COVER SHEET SMK SMK T-0286 1 Date No Description 05/23/2025 PERMIT ISSUE 07/14/2025 1 PLAN REVIEW COMMENTS 07/14/2025 COMPLETE CONSTRUCTION C C D D FF G G JJ K K L L M M 7 7 8 86 6 1 1 B B A A 2 2 3 3 4 4 5 5 EE HH (E ) S L O P E (E ) S L O P E 1 A143 2 A143 3 A143 4 A143 (E) RTU-13 T/O UNIT @ 123'-10" SCREENED BY (E) SCREENWALL (E) SCREEN WALL, T/O WALL ELEVATION @ 124'-10" (E) DHU-10 T/O UNIT @ 125'-9" SCREENED BY (E) SCREENWALL (E) REFRIGERATION, T/O UNIT @ AT 124'-10" SCREENED BY (E) SCREENWALL (E) RTU-7 T/O UNIT @ 125'-9" (E) RTU-4 T/O UNIT @ 125'-1" SCREENED BY (E) SCREENWALL (E) RTU-1 T/O UNIT @ 125'-11" W/ UNIT MOUNTED SCREENING (E) RTU-2 T/O UNIT @ 125'-11" W/ UNIT MOUNTED SCREENING (E) RTU-14 T/O UNIT @ 123'-0" SCREENED BY (E) PARAPET (E) DHU-9 T/O UNIT @ 126'-9" SCREENED BY (E) SCREENWALL RTU-8 T/O UNIT @ 126'-1" (E) DHU-6 T/O UNIT @ 126'-9" W/ UNIT MOUNTED SCREENING (E) RTU-5 T/O UNIT @ 125'-11" SCREENED BY (E) SCREENWALL (E) RTU-3 T/O UNIT @ 125'-10" SCREENED BY (E) SCREENWALL (E) RTU-12 T/O UNIT @ 125'-2" W/ UNIT MOUNTED SCREENING (E) SCREEN WALL, T/O WALL @ 124'-0" (E) RTU-11 T/O UNIT @ 125'-2" SCREENED BY (E) SCREENWALL (E) SCREEN WALL, T/O WALL @ 125'-0" (E) SCREEN WALL, T/O WALL ELEVATION @ 124'-10" (E) SCREEN WALL, T/O WALL ELEVATION @ 124'-10" (E) SCREEN WALL, T/O WALL ELEVATION @ 124'-10" (E) SCREEN WALL. (E) T/O PARAPET @ 123'-0" (E) T/O PARAPET @ 129'-0" (E) T/O PARAPET @ 125'-8" (E) T/O PARAPET @ 123'-0" (E) T/O PARAPET @ 125'-8" (E) CONDENSING UNITS T/O UNITS @ 122'-6" SCREENED BY (E) PARAPET (E) CONDENSING UNITS T/O UNITS @ 122'-6" SCREENED BY (E) SCREENWALL (E) SCREEN WALL, T/O WALL ELEVATION @ 124'-10" NOTE: THE MECHANICAL UNIT ELEVATIONS LISTED ARE CALCULATED USING AN ASSUMED 14" TALL (E) ROOF CURB, A NEW 14" ADAPTOR CURB, AND THE MANUFACTURER'S UNIT CUTSHEET. V.I.F. ACTUAL HIEGHTS AND ENSURE UNIT MOUNTED SCREENS ALIGN TO TOP OF UNITS. 52" ENVISOR UNIT MOUNTED SCREEN SYSTEM, 3 SIDES, SOLID PAN PANELS, C-10 TO MATCH ADJACENT SCREEN WALLS. SEE 52" ENVISOR UNIT MOUNTED SCREEN SYSTEM, 2 SIDES, SOLID PAN PANELS, C-10 TO MATCH ADJACENT SCREEN WALLS. SEE 52" ENVISOR UNIT MOUNTED SCREEN SYSTEM, 3 SIDES, SOLID PAN PANELS, C-10 TO MATCH ADJACENT SCREEN WALLS. SEE (E) RTU-15 T/O UNIT @ 122'-11" W/ UNIT MOUNTED SCREENING 35" ENVISOR UNIT MOUNTED SCREEN SYSTEM, 3 SIDES, SOLID PAN PANELS, C-10 TO MATCH ADJACENT SCREEN WALLS. SEE A142 1 A142 1 A142 1 A142 1 AREA OF WORK AREA OF WORK AREA OF WORK V. I . F . 66 ' - 0 1 / 4 " V.I.F. 41'-9 1/4" V. I . F . 85 ' - 2 " V.I.F. 129'-7 1/8" V.I.F. 25'-4 1/8" V. I . F . 41 ' - 1 0 3 / 4 " SCALE:1/16" = 1'-0"A141 1 ROOF PLAN GENERAL NOTES -ROOF PLAN A. B. C. D. ROOF SLOPES INDICATED ON THE PLANS INDICATE EXISTING ROOF SLOPE UNLESS NOTED OTHERWISE. E. MEMBRANE ROOFING, ROOF INSULATION, MEMBRANE FLASHING, FASTENERS, ETC ARE FURNISHED BY OWNER. SEE SPEC FOR COMPLETE LISTING. F. G. VERIFY EXISTING ROOF ELEMENTS IN AREAS OF WORK AND MODIFY/REMOVE ROOF ELEMENTS AS REQUIRED. H. G14 J. K. NOT USED. NOT USED. NOT USED. NOT USED. NOT USED. NOT USED. NOT USED. R 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 Drawn By Checked By Project Number DATE: 08/04/2025 SCOTT M. KLOPFER EXP. DATE: 02/28/2027 REG. NO. C38207 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 RSP Architects, Ltd. rsparch.com Config: XX 8/4/2025 1:55:05 PM SA N T A A N A , C A 13 3 0 E A S T 1 7 T H S T . SA N T A A N A , C A 9 2 7 0 5 A141 ROOF PLAN & DETAILS SMK SMK T-0286 SIGHTLINE VIEWPOINT 1, SOUTH ELEVATION (SIDE) SIGHTLINE VIEWPOINT 2, NORTH ELEVATION (SIDE) SIGHTLINE VIEWPOINT 3, WEST ELEVATION (FRONT) SIGHTLINE VIEWPOINT 4, EAST ELEVATION (BACK) Date No Description 05/23/2025 PERMIT ISSUE 07/14/2025 COMPLETE CONSTRUCTION RTU SCREEN NOTES A. B. C. RTU SCREEN PANEL SIZE TO VARY BASED ON OVERALL HEIGHT OF EXISTING RTU. PANEL SIZES TO BE VERIFIED IN FIELD PRIOR TO ORDERING. RTU PANELS TO BE SOLID PAN, WITH A SMOOTH FINISH. WIDE RIB PANEL SHOWN IN CUT SHEET IS FOR GENERAL REFERENCE ONLY. RTU SCREEN SYSTEM TO BE FACTORY PAINTED TO MATCH C-10. COLOR TO MATCH ADJACENT EXISTING RTU SCREEN WALLS. R 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 Drawn By Checked By Project Number DATE: 08/04/2025 SCOTT M. KLOPFER EXP. DATE: 02/28/2027 REG. NO. C38207 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 RSP Architects, Ltd. rsparch.com Config: XX 8/4/2025 1:55:05 PM SA N T A A N A , C A 13 3 0 E A S T 1 7 T H S T . SA N T A A N A , C A 9 2 7 0 5 A142 RTU SCREENS SMK SMK T-0286 A142 1 RTU SCREENINGRTU SCREENING Date No Description 05/23/2025 PERMIT ISSUE 07/14/2025 COMPLETE CONSTRUCTION C D F G J K L M 7 861 B A 2 3 4 5 E H 1 A143 1 A143 2 A143 2 A143 3 A143 3 A143 4 A143 4 A143 BUILDING FACE APPROXIMATELY 300'-0" FROM THE BUILDING FACE APPROXIMATELY 300'-0" FROM THE BUILDING FACE APPROXIMATELY 300'-0" FROM THE BUILDING FACE APPROXIMATELY 300'-0" FROM THE BU I L D I N G F A C E AP P R O X I M A T E L Y 3 0 0 ' - 0 " F R O M T H E BU I L D I N G F A C E AP P R O X I M A T E L Y 3 0 0 ' - 0 " F R O M T H E BU I L D I N G F A C E AP P R O X I M A T E L Y 3 0 0 ' - 0 " F R O M T H E BU I L D I N G F A C E AP P R O X I M A T E L Y 3 0 0 ' - 0 " F R O M T H E EL = 100' - 0" LEVEL 1 - T/O SLAB EL = 100' - 0" LEVEL 1 - T/O SLAB 7 861 EL = 119' - 0" T/O PARAPET EL = 119' - 0" T/O PARAPET 2 3 4 5 T/O (E) SCREEN WALL 125'-1" (E) RTU-12, SCREENED BY UNIT MOUNTED SCREEN T/O (E) SCREEN WALL 124'-0" (E) SCREEN WALL (E) SCREEN WALL (E) SCREEN WALL UNIT MOUNTED SCREEN 5' - 6 " BUILDING FACE APPROXIMATELY 300'-0" FROM THE BUILDING FACE APPROXIMATELY 300'-0" FROM THE T/O (E) SCREEN WALL 125'-10" (E) DHU-6, SCREENED BY UNIT MOUNTED SCREEN UNIT MOUNTED SCREEN(E) RTU-5, SCREENED BY (E) SCREEN WALL (E) RTU-3, SCREENED BY (E) SCREEN WALL (E) CU, SCREENED BY (E) BUILDING PARAPET (E) RTU-4, SCREENED BY (E) SCREEN WALL EL = 100' - 0" LEVEL 1 - T/O SLAB EL = 100' - 0" LEVEL 1 - T/O SLAB CDFGJKLM B A EL = 119' - 0" T/O PARAPET EL = 119' - 0" T/O PARAPET EH T/O (E) SCREEN WALL 125'-10" (E) RTU-3, SCREENED BY (E) SCREEN WALL T/O (E) SCREEN WALL 126'-9" (E) SCREEN WALL (E) SCREEN WALL (E) SCREEN WALL BUILDING FACE APPROXIMATELY 300'-0" TO THE BUILDING FACE APPROXIMATELY 300'-0" FROM THE 5' - 6 " (E) CU, SCREENED BY (E) SCREEN WALL (E) DHU-6, SCREENED BY UNIT MOUNTED SCREEN UNIT MOUNTED SCREEN (E) RTU-1, SCREENED BY UNIT MOUNTED SCREEN UNIT MOUNTED SCREEN (E) RTU-2 (BEYOND), SCREENED BY UNIT MOUNTED SCREEN UNIT MOUNTED SCREEN (E) DHU-9, SCREENED BY (E) SCREEN WALL (E) RTU-8, SCREENED BY (E) SCREEN WALL (E) RTU-5, SCREENED BY (E) SCREEN WALL EL = 100' - 0" LEVEL 1 - T/O SLAB EL = 100' - 0" LEVEL 1 - T/O SLAB C D F G J K L MBA EL = 119' - 0" T/O PARAPET EL = 129' - 0" T/O (E) PARAPET E H (E) RTU-12, SCREENED BY UNIT MOUNTED SCREEN T/O (E) SCREEN WALL 124'-0" T/O (E) SCREEN WALL 125'-0" (E) SCREEN WALL T/O (E) SCREEN WALL 127'-1"T/O (E) SCREEN WALL 126'-9" (E) SCREEN WALL(E) SCREEN WALL BUILDING FACE APPROXIMATELY 300'-0" FROM THE BUILDING FACE APPROXIMATELY 300'-0" FROM THE 5' - 6 " 5' - 6 " UNIT MOUNTED SCREEN (E) RTU-15, SCREENED BY UNIT MOUNTED SCREEN UNIT MOUNTED SCREEN EL = 100' - 0" LEVEL 1 - T/O SLAB EL = 100' - 0" LEVEL 1 - T/O SLAB 7 861 EL = 119' - 0" T/O PARAPET EL = 119' - 0" T/O PARAPET 2 3 4 5(E) RTU-14, SCREENED BY (E) SCREENWALL (E) RTU-2, SCREENED BY UNIT MOUNTED SCREEN T/O (E) SCREEN WALL 124'-10" T/O (E) SCREEN WALL 127'-1" BUILDING FACE APPROXIMATELY 300'-0" FROM THE 5' - 6 " BUILDING FACE APPROXIMATELY 300'-0" FROM THE 5' - 6 " (E) RTU-15, SCREENED BY UNIT MOUNTED SCREEN (E) RTU-1, SCREENED BY UNIT MOUNTED SCREEN UNIT MOUNTED SCREEN UNIT MOUNTED SCREEN UNIT MOUNTED SCREEN R 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 Drawn By Checked By Project Number DATE: 08/04/2025 SCOTT M. KLOPFER EXP. DATE: 02/28/2027 REG. NO. C38207 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 RSP Architects, Ltd. rsparch.com Config: XX 8/4/2025 1:55:07 PM SA N T A A N A , C A 13 3 0 E A S T 1 7 T H S T . SA N T A A N A , C A 9 2 7 0 5 A143 ROOF PLAN SIGHTLINES SMK SMK/RDP T-0286 SCALE:1/16" = 1'-0"A143 1 SITELINE SECTION 1 SCALE:1/16" = 1'-0"A143 2 SITELINE SECTION 2 SCALE:1/16" = 1'-0"A143 3 SITELINE SECTION 3 SCALE:1/16" = 1'-0"A143 4 SITELINE SECTION 4 GENERAL NOTES A. ALL DHUs SHOWN ARE NEW ON EXISTING CURBS. EXISTING UNITS ARE NOT SHOWN FOR CLARITY OF SCOPE OF WORK B. DHU, CURB ADAPTER, AND EXISTING CURB HEIGHTS ARE ALL PROVIDED BY MECH C. PARAPET HEIGHTS AND APPROXIMATE ROOF SLOPES ARE CALCULATED FROM EXISTING DRAWINGS D. NO SPOT ELEVATIONS WERE AVAILABLE FOR USE IN THE PREPERATION OF THESE SECTION STUDIES. GRADE IS ASSUMED TO BE 100'-0" E. UPON INSTALLATION, ANY VISIBLE EQUIPMENT SHALL BE SCREENED PER THE ZONING CODE. 1 Date No Description 05/23/2025 PERMIT ISSUE 07/14/2025 1 PLAN REVIEW COMMENTS 07/14/2025 COMPLETE CONSTRUCTION RTU SCREEN NOTES A. B. C. RTU SCREEN PANEL SIZE TO VARY BASED ON OVERALL HEIGHT OF EXISTING RTU. PANEL SIZES TO BE VERIFIED IN FIELD PRIOR TO ORDERING. RTU PANELS TO BE SOLID PAN, WITH A SMOOTH FINISH. WIDE RIB PANEL SHOWN IN CUT SHEET IS FOR GENERAL REFERENCE ONLY. RTU SCREEN SYSTEM TO BE FACTORY PAINTED TO MATCH C-10. COLOR TO MATCH ADJACENT EXISTING RTU SCREEN WALLS. R 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 Drawn By Checked By Project Number DATE: 05/23/2025 SCOTT M. KLOPFER EXP. DATE: 02/28/2027 REG. NO. C38207 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 RSP Architects, Ltd. rsparch.com Config: XX 5/26/2025 10:00:21 PM SA N T A A N A , C A 13 3 0 E A S T 1 7 T H S T . SA N T A A N A , C A 9 2 7 0 5 A142 RTU SCREENS SMK SMK T-0286 Date No Description 05/23/2025 PERMIT ISSUE A142 1 RTU SCREENINGRTU SCREENING 02/28/202502/28/2027 05/26/25 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs