HomeMy WebLinkAbout1303 N Bristol St - REV 1 - PlanSITE
49,085 S.F.
2,973 S.F.
BUILDING CODE
REFERENCE CODE
ELECTRICAL CODE
PLUMBING CODE
MECHANICAL CODE
FIRE CODE
ENERGY CODE
ACCESSIBILITY CODE
GREEN BUILDING CODE
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA FIRE CODE
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA BUILDING CODE CHAPTER 11B
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE - CAL GREEN
SITE STATISTICS *SEE CIVIL DRAWINGS FOR ALL OTHER SITE INFORMATION
NOT SHOWN ON THIS COVER SHEET
PARKING STATISTICS
2021 CALIFORNIA RETAIL FOOD CODEHEALTH CODE
SCOPE OF WORK:RESTROOM PLUMBING FIXTURES
SEE SHEET CRA FOR RESTROOM PLUMBING FIXTURE REQUIREMENTSGROUND UP CONSTRUCTION OF A NEW RESTAURANT WITH ATTACHED CORRAL OUTDOOR PATIO COVER AREA. INCLUDED IN THIS
WORK UNDER THIS PERMIT ARE THE FOLLOWING:
1.DRIVE-THRU WINDOW CANOPY
2.MENU BOARD FOOTINGS AND CANOPY
3.OUTDOOR PATIO COVER
4.TRASH ENCLOSURE WITH METAL COVER
5.LIGHT POLE FOOTINGS
6.DRIVE-THRU EQUIPMENT FOOTINGS
7.LANDSCAPE AND IRRIGATION
1.REFER TO SHEET GN1.0 FOR GENERAL NOTES AND REFER TO SHEET GN1.1 FIRE DEPT. & HEALTH DEPT. NOTES
2.THE STATED DIMENSIONS SHALL TAKE PRECEDENCE OVER GRAPHICS. DO NOT SCALE THE DRAWINGS. THE ARCHITECT SHOULD BE NOTIFIED OF ANY DISCREPANCIES.
3.DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS ARE NOT INTENDED AND SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR OWNER PRIOR TO CONTINUING WITH THE AFFECTED
PORTIONS OF THE WORK.
4.THE BIDDING AND CONSTRUCTION OF THE PROJECT WILL BE ADMINISTERED BY THE OWNER.
5.THE APPROVED PLANS (FOR CONSTRUCTION) SET SHALL BE KEPT ON SITE AT ALL TIMES, INCLUDING ALL ADDENDA, SUPPLEMENTAL INSTRUCTIONS, CHANGE ORDERS AND COPIES OF APPROVED SUBMITTALS.
6.AT ALL TIMES, THE GENERAL CONTRACTOR SHALL CLOSELY SUPERVISE THE WORK OF ALL SUBCONTRACTORS AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS & TECHNIQUES,
INCLUDING SAFETY PROCEDURES AND / OR COORDINATING / SEQUENCING ALL TRADES.
7.THE GENERAL CONTRACTOR IS RESPONSIBLE TO CARRY WORKMEN'S COMPENSATION AS REQUIRED BY LAW AND / OR GOVERNING AUTHORITY,
8.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE SAFETY & CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION.
9.THE GENERAL CONTRACTOR SHALL ADHERE AND COMPLY WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS REGARDING JOB SITE SAFETY.
10.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK AND THAT OF HIS SUBCONTRACTORS FOR LOSSES AND DAMAGES TO EQUIPMENT, TOOLS AND MATERIALS USED IN CONJUNCTION WITH THE WORK
FOR FOR ACTS OF HIS EMPLOYEES AND ALL SUBCONTRACT WORKERS.
11.CLEANING: THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE OF CONSTRUCTION DEBRIS & TRASH.
*SEE CIVIL DRAWINGS FOR ALL OTHER SITE INFORMATION
NOT SHOWN ON THIS COVER SHEET
A ANNEALED
AC AIR CONDITIONING
ACT ACOUSTIC CEILING TILE
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
AL ALUMINUM
BLCKG BLOCKING
ASPH ASPHALT
CJ CONTROL JOINT
CLNG CEILING
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CPT CARPET
CT CERAMIC TILE
CL CENTERLINE
DBL DOUBLE
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DWG DRAWING
DS DOWNSPOUT
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATION
EQ EQUAL
EXIST EXISTING
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FR FIRE RATED
FRP FIBERGLASS REINFORCED PLASTIC
GALV GALVANIZED
GYP BD GYPSUM BOARD
HC HANDICAP
HDW HARDWARE
HM HOLLOW METAL
HT HEIGHT
HVAC HEATING,VENTILATION, AIR
CONDITIONING
INSUL INSULATION
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MO MASONRY OPENING
MR MOISTURE RESISTANT
MTL METAL
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OPP OPPOSITE
PF PRE-FABRICATED
PSF POUNDS PER SQUARE FOOT
PT PRESSURE TREATED
PTD PAINTED
QT QUARRY TILE
R RADIUS
REBAR REINFORCING BAR
REF REFERENCE
REQ'D REQUIRED
RO ROUGH OPENING
SF STOREFRONT
SB SPLASHBLOCK
SIM SIMILAR
SPEC SPECIFICATION
SS STAINLESS STEEL
STL STEEL
STOR STORAGE
SUSP SUSPENDED
T TEMPERED
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
WD WOOD
WP WATERPROOF
WWF WELDED WIRE FABRIC
LANDLORD CIVIL ENGINEER
KIESEL DESIGN
422 E. MAIN STREET
VENTURA, CA 93001
PHONE: 805-947-0730
CONTACT: JACK KIESEL
jack@kieseldesign.com
LANDSCAPE ARCHITECT MEP ENGINEER
STRUCTURAL ENGINEER
SIGNS & AWNINGSSOILS ENGINEER
TERRACON
50 GOLDENLAND CRT. STE. 100
SACRAMENTO, CA 95834
PHONE: 916-246-5096
CONTACT: STAYSHA DELGADO
staysha.delgado@terracon.com
ARCHITECTTENANT
UTILITY CONSULTANT
E4
324 Avenida De La Estrella, Ste B
SAN CLEMENTE, CA 92672
PHONE: 949-353-5134
CONTACT: NICOLE CAPLAN
nicole@4design.com
PROJECT
COVER SHEET
PCS
WRIGHT ENGINEERS
2 VENTURE, SUITE 200
IRVINE, CA 92618
PHONE:949-477-4001
FAX:559-323-9633
CONTACT: TOM ALLEN
tallen@wrightengineers.com
2022 CALIFORNIA ELECTRICAL CODE
32,549 S.F.
13,369 S.F.
CITY OF SANTA ANA MUNICIPAL CODEMUNICIPAL CODE
1.SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
RESPONSIBLE CHARGE, WHO SHALL REVIEW THEM AND THAT THEY
HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE
DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL
NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS
HAVE BEEN APPROVED BY THE BUILDING OFFICIAL.
2.PLANS FOR THE DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED IN
A TIMELY MANNER THAT ALLOWS A MINIMUM OF 30 DAYS FOR INITIAL
PLAN REVIEW. ALL COMMENTS RELATED TO THE DEFERRED SUBMITTAL
MUST BE ADDRESSED TO THE SATISFACTION OF THE PLAN CHECK
DIVISION PRIOR TO APPROVAL OF THE SUBMITTAL ITEMS.
3.DEFERRED ITEMS SHALL BE SUBMITTED BY THE GENERAL
CONTRACTOR TO THE LOCAL JURISDICTION FOR REVIEW AND
APPROVAL PRIOR TO INSTALLATION.
SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING:
1.SIGNAGE AND MENU BOARD
2.FIRE SPRINKLERS
3.FIRE ALARM
4.FIRE SERVICE UNDERGROUND SYSTEM
5.C02.
SP1 BRISTOL STREET CORRIDOR
RESTAURANT #C1032
1303 N Bristol St.
Santa Ana, CA 92706
P6E-AV- SCHEME B
03
A
R
C
H
I
T
E
C
T
U
R
A
L
07
P
L
U
M
B
I
N
G
08
E
L
E
C
T
R
I
C
A
L
01
G
E
N
E
R
A
L
FRAMING PLANA1.20
DOOR SCHEDULE & ELEVATIONSA2.10
FINISH FLOOR PLAN A3.20
INTERIOR ELEVATIONSA5.20
RESTROOM PLAN AND ELEVATIONS
BUILDING SECTIONSA6.10
WALL SECTIONSA7.10
WALL SECTIONS
WALL SECTIONS
WALL SECTIONS
A8.20
REFLECTED CEILING PLANA1.30
ROOF PLANA1.50
PROJECT COVER SHEET PCS
SLAB COORDINATION PLANA1.21
KEYNOTE FLOOR PLANA1.10
TRASH ENCLOSURE PLAN & DETAILS
A0.21
DOOR DETAILSA2.11
WINDOW SCHEDULE & ELEVATIONSA2.20
A3.10 FINISH SCHEDULE
EXTERIOR ELEVATIONSA4.10
EXTERIOR ELEVATIONSA4.20
INTERIOR ELEVATIONSA5.10
A5.30
A7.20
A7.30
A7.40
PLAN DETAILSA8.10
SECTION DETAILS
A8.30 INTERIOR DETAILS
A8.31 INTERIOR DETAILS
ENLARGED REFLECTED CEILING PLANA1.31
WINDOW DETAILSA2.21
ROOF FRAMING PLANS2.1
FOUNDATION DETAILSS4.1
S4.2
FRAMING DETAILS
HVAC FLOOR PLANM1.1
HVAC SCHEDULES AND DETAILSM2.1
KITCHEN HOOD DETAILS AND HVAC SPECS.M3.1
WATER PLUMBING PLANP1.1
ROOF PLUMBING PLANP2.1
WASTE, VENT & GAS RISER DIAGRAMP3.1
PLUMBING DETAILSP4.1
PLUMBING SPECIFICATIONSP6.1
ELECTRICAL SITE PLAN
POWER FLOOR PLANE2.1
LIGHTING FLOOR PLAN
RISERS, SCHEDULES AND DETAILSE3.1A
LIGHTING FIXTURE SCHEDULEE3.2
ELECTRICAL DETAILS
ELECTRICAL SPECIFICATIONSE4.2
EQUIPMENT FLOOR PLANFS1.10
EQUIPMENT SCHEDULEFS2.10
EQUIPMENT KEY PLAN FS3.10
EQUIPMENT INTERIOR ELEVATIONSFS3.20
FS3.30
FS3.40
FS3.50
M3.2
P5.1
HVAC ROOF PLANM1.2
GREASE RECLAMATION DETAILSP7.1
E1.0
A8.40 ROOF DETAILS
A8.21 SECTION DETAILS
WINDOW DETAILSA2.22
PLUMBING CALCULATIONS
ENLARGED ELEVATIONS & DETAILSA4.30
TRUSS COORDINATION PLANA1.40
WALL SECTIONSA7.50
WATER RISER DIAGRAMP3.2
E3.3
A0.20
ACCESSIBILITY SITE PLANA0.10
SEATING FLOOR PLANFS1.11
CO2 DETAILSP4.2
WALL SECTIONSA7.60
PATIO PLANA0.12
ACCESSIBILITY SITE DETAILSA0.11
SITE DETAILS
INDEX OF DRAWINGS
NOTESSH
E
E
T
TI
T
L
E
DI
S
C
I
P
L
I
N
E
NOTESSH
E
E
T
TI
T
L
E
DI
S
C
I
P
L
I
N
E
SHEET DESCRIPTION
GENERAL & BID NOTESGN1.0
FOUNDATION DETAILS
S6.1 TRASH ENCLOSURE FRAMING & FOUNDATION PLANS
S6.2 TRASH ENCLOSURE DETAILS
KITCHEN HOOD NOTES AND HVAC NOTES
WASTE & GREASE PLUMBING PLANP1.2
POWER ROOF PLANE2.3
PLUMBING SITE PLANP1.0
WALL SECTIONSA7.70
UTILITY PLAN
EROSION CONTROL PLAN
CIVIL COVER SHEETC1.0
GRADING AND DRAINAGE PLAN
CONSTRUCTION DETAILS
02
C
I
V
I
L
(
F
O
R
R
E
F
E
R
E
N
C
E
)
HOOD DRAWINGS (FOR REFERENCE)
ELECTRICAL COVER SHEETE0.0
CEILING DETAILSA1.32
EXISTING CONDITIONS
03
L
A
N
D
S
C
A
P
E
IRRIGATION PLANL2.1
L2.2
L2.3
L3.1
L3.2
PLANTING PLAN
L3.3
L3.4
PLANTING & MULCH DETAILS
L3.5
PLANTING SPECIFICATIONS
COVER SHEETL0.0
MATERIALS PLANL1.1
SOILS REPORT
IRRIGATION NOTES
L2.4
IRRIGATION DETAILS
L2.5
IRRIGATION DETAILS
L2.6 IRRIGATION SPECIFICATIONS
PATIO FINISH & SAWCUT PLANL1.2
IRRIGATION DETAILS
L2.7 IRRIGATION SPECIFICATIONS
PLANTING SPECIFICATIONS
REMOTE CANOPY PLAN & DETAILS.
ELECTRICAL DETAILSE3.4
SITE KEYNOTE PLAN
A0.31
REMOTE CANOPY PLAN & SECTIONSA0.32
PATIO RCP, ROOF PLANA0.13
KIMLEY HORN
245 E. THIRD STREET,
LONG BEACH, CA 90802
PHONE: 652-549-2132
CONTACT: JULIA CHANG
julia.chang@kimley-horn.com
PLANNING DIVISION
20 CIVIC CENTER PLAZA
SANTA ANA, CA 92701
PHONE:714-667-2700
CITY OF SANTA ANA
HEALTH DEPARTMENT
1241 E. DYER RD. SUITE 120
SANTA ANA, CA 92707
PHONE: 714-433-6074
ORANGE COUNTY
CHARLES MANH AND ANN MANH,
AS TRUSTEES OF THE MANH FAMILY
TRUST
PHONE: 714-642-5573
CONTACT: CHARLIE MANH
charliemanh@hotmail.com
REMOTE CANOPY PLANSS3.1
L3.6
PRIVATE GENERAL NOTES
06
M
E
C
H
A
N
I
C
A
L
C1.1
C2.0
C3.0
C5.0
C6.0
C6.1
C7.0
C8.0
EQUIPMENT INTERIOR ELEVATIONS
EQUIPMENT INTERIOR ELEVATIONS
EQUIPMENT INTERIOR ELEVATIONS
DEFERRED SUBMITTALS SHALL INCLUDE THE FOLLOWING:
A.FIRE SPRINKLERS
B.FIRE ALARM SYSTEM - SEE FIRE DEPT. NOTE #3
ON SHEET GN1.0
C.PRE-FABRICATED WOOD TRUSSES
D.WALK-IN COOLER/FREEZER UNIT
E.MENU BOARD & SIGNAGE
F.KITCHEN HOOD PACKAGE
G.DUCT FIRE EXTINGUISHING SYSTEM
H.FIRE SERVICE UNDERGROUND SYSTEM
05
S
T
R
U
C
T
U
R
A
L
GRADING AND DRAINAGE PLAN
S5.1
FRAMING DETAILSS5.2
FRAMING DETAILSS5.3
FRAMING DETAILSS5.4
FRAMING DETAILSS5.5
AGI
412 N. CEDAR BLUFF RD.
SUITE 306
KNOXVILLE, TN 37923
PHONE: 800-877-7868 X3204
CONTACT: MEGAN WIGGINS
mwiggins@agi.net
ACCESSIBILITY DETAILS AC1
CALGREEN CHECK LISTG0.11
CRA CODE REFERENCE ANALYSIS
CONDITIONS OF APPROVAL COA
ACCESSIBILITY DETAILS AC2
ACCESSIBILITY DETAILS AC3
ACCESSIBILITY DETAILS AC4
CALGREEN CHECK LISTG0.12
CALGREEN CHECK LISTG0.13
CALGREEN CHECK LISTG0.14
04
A
W
N
I
N
G
S0.8
S1.1 FOUNDATION PLAN
S0.5
S0.7
S0.4
S0.6
NOTES AND SCHEDULES
TYPICAL DETAILS
TYPICAL DETAILS
TYPICAL DETAILS
TYPICAL DETAILS
GENERAL STRUCTURAL NOTES
GENERAL STRUCTURAL NOTES
GENERAL STRUCTURAL NOTESS0.3
S0.2
S0.1
E2.2
RISERS, SCHEDULES AND DETAILSE3.1B
VOLTAGE DROP CALCULATIONSE4.4
DRIVE THRU CANOPY PLAN & DETAILS.A0.30
SP1 BRISTOL STREET CORRIDOR
RAISING CANE'S RESTAURANTS, L.L.C.
6800 BISHOP RD
PLANO, TX 75024
PHONE: 423-807-0008
CONTACT: SARAH HOLMES
sholmes@hdgroupinc.com
BUILDING DIVISION
20 CIVIC CENTER PLAZA
ROSS ANNEX, M-20
SANTA ANA, CA 92701
PHONE: 714-647-5800
CITY OF SANTA ANA
FIRE DEPARTMENT
1439 S BROADWAY
SANTA ANA, CA 92707
PHONE: 714-567-3236
ORANGE COUNTY FIRE
AUTHORITY
EROSION CONTROL DETAILC3.1
DEMOLITION PLANC4.0
DIMENSIONAL CONTROL AND SITE PLANC5.1
C6.2 GRADING SECTIONS
CONSTRUCTION DETAILSC8.1
DRIVE THRU CANOPY PLANE1.1
ELECTRICAL SITE PHOTOMETRICSE1.2
CONSTRUCTION TYPE
OCCUPANCY
FIRE SPRINKLERS
HEIGHT OF BUILDING
MAXIMUM STORIES
MAXIMUM AREA
BUILDING AREA
TOTAL OCCUPANT LOAD
TYPE VB
ASSEMBLY (A-2)
YES
40-FEET ALLOWED
ONE (1)
24,000 S.F. ALLOWED
3,540 S.F. (INCLUDING CORRAL)
87 - SEE SHEET CRA
BUILDING AREA (GROSS AREA)
CORRAL AREA
OUTDOOR PATIO
BUILDING HEIGHT
405 - 272 - 24, PARCEL 1, 2, & 3
TOTAL SITE AREA
BUILDING AREA
IMPERVIOUS AREA
LANDSCAPE AREA
LAND USE
ZONING
APN
2,973 S.F.
290 S.F.
±1232 S.F.
23'-4" T.O. PARAPET
PM DESIGN GROUP, INC.
76 E. MITCHELL DR.
PHOENIX, AZ 85012
CELL PHONE: 623-432-0596
CONTACT: CHUCK BENNETT
cbennett@pmdginc.com
A9.10
A9.20
A9.30
A9.40
A9.50
A9.60
PROJECT SPECIFICATIONS
PROJECT SPECIFICATIONS
PROJECT SPECIFICATIONS
PROJECT SPECIFICATIONS
PROJECT SPECIFICATIONS
PROJECT SPECIFICATIONS
M3.3
M3.4
M3.5
M3.6
M3.7
M3.8
M3.9
M3.10
M3.11
M3.12
M3.13
M3.15
M3.16
M3.17
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
HOOD DRAWINGS (FOR REFERENCE)
09
F
O
O
D
S
E
R
V
I
C
E
BU
I
L
D
I
N
G
SU
B
M
I
T
T
A
L
CODE INFORMATION PROJECT STATISTICS
BUILDING CODE ANALYSIS
GENERAL PROJECT NOTES:
ABBREVIATIONS
PROJECT TEAM & CONTACT INFORMATION VICINITY MAP
DEFERRED SUBMITTALS:SEPARATE PERMITS:
PM DESIGN GROUP, INC.
19401 40th AVE. WEST, SUITE 420
LYNNWOOD, WA 98036
PHONE:425-409-2496
CONTACT: JAMES YBARRA
JYBARRA@PMDGINC.COM
DOOR DETAILSA2.12
WINDOW DETAILSA2.23
PLAN DETAILSA8.11
PUBLIC GENERAL NOTESC2.1
CONSTRUCTION DETAILSC8.2
PLANTING SPECIFICATIONS
STRUCTURALS.1
STRUCTURALS.2
STRUCTURALS.3
STRUCTURALS.4
S4.3 FOUNDATION DETAILS
M3.14
M3.18 HOOD DRAWINGS (FOR REFERENCE)
M3.19 HOOD DRAWINGS (FOR REFERENCE)
M3.20 HOOD DRAWINGS (FOR REFERENCE)
M3.21 HOOD DRAWINGS (FOR REFERENCE)
M4.1 T-24 FORMS
ELECTRICAL SPECIFICATIONSE4.1
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
LL
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Professional of Record:JEFF LIEDERMAN
Kitchen Issue Date:
10
76 E. MITCHELL DR.
PHOENIX, AZ 85012
CONTACT: CHUCK BENNETT
(623) 432-0596
CBENNETT@PMDGINC.COM
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:CB
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
ARCHITECTURE SITE PLANA0.09
BU
I
L
D
I
N
G
SU
B
M
I
T
T
A
L
M4.2 T-24 FORMS
M4.3 T-24 FORMS
M4.4 T-24 FORMS
M4.5 T-24 FORMS
M4.6 T-24 FORMS
ENERGY CODE COMPLIANCE FORMSE4.3A
ENERGY CODE COMPLIANCE FORMSE4.3B
WALL SECTIONSA7.80
SE
Q
.
#
SE
Q
.
#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
99
96
97
98
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
1
1
24'-8" T.O. ENTRY TOWER
NOTES
THE PROJECT ADDRESS IS IN THE FEMA DESIGNATED ZONE X.4
192 ENERGY CODE COMPLIANCE FORMSE4.3C
COVER SHEET001
GENERAL NOTES002
GENERAL NOTES003
DEMOLITION PLAN004
STREET IMPROVEMENT PLAN & PROFILE 005
006
007
NOTES AND DETAILS001
002 NORTH BRISTOL STREET
193
194
195
196
197
198
199
200
201
STREET IMPROVEMENT PLAN & PROFILE
WATER & SEWER IMP. PLAN & PROFILE
1 2 4
A
C
E
3 3.70.70.6
Y
1.11 2 4
A
C
E
1 4
3.2 3.8
F
3 3.70.7
0.6 0.7
0.6
Y
1.1
1 1/4" = 1'-0"
FRAMING PLAN
1.ALL EXTERIOR STUD DIMENSIONS ARE TO FACE OF PLYWOOD / CONC. FOOTING, TYPICAL U.N.O. - SEE A1.21
FOR SLAB DIMENSIONS & FOUNDATION PLAN
2.ALL INTERIOR STUDS DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE
3.ALL STUDS ARE TO BE 16" O.C. UNLESS NOTED OTHERWISE.
4..FINISH MATERIALS AND THICKNESS NOT SHOWN FOR CLARITY. REFER TO SHEET A3.20 FINISH FLOOR PLAN.
4. REFER TO STRUCTURAL FRAMING & SHEAR WALL PLANS AND SCHEDULES FOR DETAILS AND REQUIRED
SHEATHING.
5.ALL KITCHEN AREA & WET WALLS TO HAVE DUROCK BRAND CEMENT BOARD FROM F.F. TO 8" A.F.F. W/ 1/2"
PLYWOOD ABOVE. FINISH AS SCHEDULED.
6. REFER TO SHEETS FS1.10 & FS2.10 FOR BLOCKING LOCATIONS AND REQUIREMENTS OF OWNER PROVIDED
MILLWORK, INSTALLED BY GENERAL CONTRACTOR.
7.REFER TO SHEET A1.30 FOR HEADER AND SOFFIT LOCATIONS AND HEIGHTS.
8. DIMENSION LEADERS ARE LOCATED AT EDGE OF SLAB, EDGE OF BRICK, VISIBLE FACE OF MASONRY, FACE
OF STUDS OR CENTERLINE OF STUDS UNLESS NOTED OTHERWISE.
9.FOR ALL AIR CONDITIONING, EXHAUST & SUPPLY FANS, HVAC & REFRIGERATION EQUIPMENT CURBS;
GENERAL CONTRACTOR SHALL PROVIDE & INSTALL SUITABLE BLOCKING IN WALLS & CEILINGS TO SUPPORT
FIXTURES, EQUIPMENT & CANOPIES.
10. G.C. SHALL PROVIDE NECESSARY BLOCKING FOR ALL OWNER PROVIDED SIGNAGE & TABLE SUPPORTS.
11.G.C. SHALL PROVIDE NECESSARY BLOCKING FOR ALL OWNER PROVIDED SIGNAGE & TABLE SUPPORTS.
GENERAL NOTES
THE FOLLOWING ROOMS SHALL HAVE 1/2" DURCOCK BRAND CEMENT BOARD
FROM F.F. TO 4" A.F.F. WITH 1
2" PLYWOOD ABOVE IN LIEU OF G.W.B. (ON INTERIOR
SIDE) EXCEPT AT HOOD. F.R.P FINISH AS SCHEDULED: SEE SHEET A3.20.
DUROCK BRAND CEMENT BOARD SHALL BE CONTINUOUS BEHIND ENTIRE
LENGTH OF HOOD FROM FLOOR TO 18" ABOVE SUSPENDED CEILING AND
EXTEND 18" ON EACH SIDE OF HOOD.
1. KITCHEN
2. B.O.H.
3. STORAGE
PLYWOOD BACKING NOTE
EXTERIOR WALL
METAL STUD (16 GA.)
CONSTRUCT PER UL263-U433: METAL STUDS WITH 3-1 2 " UNFACED MINERAL FIBER
INSULATION WITHIN WALL CAVITY
INTERIOR WALL
WALL LEGEND
WALL TYPES LEGEND
ASSEMBLY
TYPES
2x4 WOOD STUDS @ 16" O.C. UNLESS NOTED OTHERWISE
2x6 WOOD STUDS @ 16" O.C. UNLESS NOTED OTHERWISE. EXTERIOR PERIMETER WALLS TO
RECEIVE CAVITY INSULATION AS INDICATED IN SPECIFICATIONS.
2x8 WOOD STUDS @ 16" O.C. UNLESS NOTED OTHERWISE
HYPHENATED NUMBERS DENOTE DOUBLE-STUD WALL
CONSTRUCT PER UL263-U433: 1 1/2" & 6" METAL STUDS WITH 3-1 2 " UNFACED MINERAL FIBER
INSULATION WITHIN WALL CAVITY
REINFORCED CONCRETE MASONRY WALL
SHEAR WALL, RE: STRUCTURAL
SHEATHING
TYPES
EXTERIOR PLYWOOD SHEATHING
1 2" CDX PLYWOOD OR OSB SHEATHING WITH 4" STRIP OF CEMENT BOARD AT BASE
1 2" CDX PLYWOOD OR OSB SHEATHING WITH 4" STRIP OF CEMENT BOARD AT BASE + 1 2" GYPSUM
WALLBOARD
1 2" CDX PLYWOOD OR OSB SHEATHING WITH 4" STRIP OF CEMENT BOARD AT BASE + 1 4" TILE
BACKER BOARD
1 2" FIBER CEMENT BOARD
CONSTRUCT PER UL263-U433: 5 8" CEMENT BOARD SHEATHING ON BOTH SIDES
4
6
8
UL
CM
P P
PG PG
PT PT
CB CB
X X
UL UL
#-#DRIVE-THRU
PAY
DRIVE-THRU
PICKUP
KITCHEN
DINING ROOM
SERVING AREA
CUSTOMER PICK UP
RESTROOM
VESTIBULE
RESTROOM 1
RESTROOM 3
MECH.
ROOM
FREEZER
COOLER
EXTERIOR CORRAL
KITCHEN (BOH)
KITCHEN
52'-1"
24'-3"3'-10"
R.O.
1'-11"
60
'
-
4
"
13
'
-
7
1
2"
52'-1"
4'-3"11'-71 2"
R.O.
21'-61 2"4'-01 2"
R.O.
1'-9"
25
'
-
0
"
14
'
-
0
1
2"
18'-1"23'-0"
12'-2"
55
'
-
8
"
20
'
-
0
1
2"
R.
O
.
24
'
-
7
"
3'
-
1
0
1
2"
1'
-
0
"
2'
-
0
1
2"
R.
O
.
10
"
12'-2"
1'
-
8
1
2"
8'
-
2
1
4"
4'
-
3
"
4'
-
0
1
2"
14
'
-
1
3
4"
6'
-
9
"
9'
-
0
1
2"
7'
-
0
1
4"
2'
-
5
"
4'
-
1
1
1
2"
3'
-
3
"
2'
-
1
1
"
5'
-
3
1
2"
5'
-
9
"
6'
-
4
"
5'
-
6
"
6'
-
8
"
7'
-
3
"
3'
-
2
"
4'
-
5
1
2"
3'
-
1
"
4'
-
5
1
2"
2'
-
4
1
2"
4'
-
4
"
R.
O
.
4'
-
7
3
4"
1'
-
1
"
22
'
-
3
1
4"
5'-51 2"3'-61 2"
3'-4"3'-4"
1'-81 2"
9'-31 2"
1'-91 2"
2'-8"3'-2"3'-3"6'-11"
13'-4"
9'-2"
8'-53 4"
2'-91 2"
5'-9"
3'-4"4'-51 2"
2'
-
5
1
2"
COLUMN
RE: STRUCTURAL
EDGE OF CEILING SOFFIT
FRAMING ABOVE. RE: RCP
EDGE OF CEILING SOFFIT
FRAMING ABOVE
EDGE OF CEILING SOFFIT
FRAMING ABOVE
EDGE OF CEILING SOFFIT
FRAMING ABOVE
1'-10"
9'-7"
8'-61 2" R.O.
6"
7'
-
0
1
2"
R
.
O
.
13
'
-
5
1
2"
R
.
O
.
6"
3'
-
2
1
2"
2'
-
0
"
1'
-
3
"
3'-3"13'-11"
6'-0"5'-0"
10
'
-
4
"
COLUMN
RE: STRUCTURAL
3'
-
2
1
2"
5'
-
3
"
2'
-
9
1
2"
12'-21 2"3'-51 2"
11"
COLUMN
RE: STRUCT.
3" PVC PIPE CHASE TO
RUN BETWEEN KITCHEN
THROUGH WALL TO
BEVERAGE CABINET
(FOR KETCHUP LINES),
RE: 11/A8.10
ELECTRICAL PANEL
ROUGH-IN. RE: ELEC
7'-0"
3x3 STEEL POST,
RE: STRUCTURAL
51 2"
6'
-
4
"
R.
O
.
1'
-
4
"
7"
3'
-
4
"
4"
4'-01 2"
5'-31 2"
RESTROOM 2
1'-1"
3'
-
0
"
12
'
-
1
"
3'-63 4"13'-0"
3'
-
9
1
2"
1'
-
0
"
6'
-
8
"
11
'
-
3
"
BLOCKING SUSPENDED
FROM TRUSS BOTTOM
CHORD
EDGE OF CEILING SOFFIT
FRAMING ABOVE
EDGE OF CEILING SOFFIT
FRAMING ABOVE
13'-1"13'-8"11'-0"
3'
-
0
"
4P PT
6P P
4
P
P
6
P
PT
4
P
PT
6
P
PT
6
P
PT
6
P
PT
6PG X
6PT PT
6
PT
X
6
P
X
4PT
6
PT
4P PT
6X P
4PT P
4
P
P
6
PT
P
4P P
4PT PT
4
P
P
6X CB
4 PT
4
PT
4
P
PT
4
P
PT
4
P
PT
6P PT
6CB P
6X P
6
P
P
6P PT
6X CB
6
CB
P
6
P
P
6
P
P
4P P 4P P
6
X
P
4P P
6X P
6X P
6-
4
P
P
6
X
UL
ULUL UL
6
X
P
6
PT
X
6P X
5'-6"
PARTIAL HEIGHT WALL
9'-61 2"3'-101 2"4'-1"6'-2"10'-0"9'-6"2'-11"5'-0"
PARTIAL HEIGHT WALL
3'-5"
PARTIAL HEIGHT WALL
2'
-
8
1
2"
7"
7"
2'
-
8
1
2"
4'
-
8
"
4'-0"
4'-91 4"4'-91 4"
1'
-
0
"
3'
-
6
1
2"
R.
O
.
11
2"
6"
3'
-
6
1
2"
R.
O
.
11
2"
3'-6"10'-0"3'-6"
6
PT
PT
6
PT
PT
6-
4
PT
X
6-
6
PT
X
1'-63 4"
6'
-
4
1
2"
6-6PT X
6PT X
6PT X
6X P
6
X
P
6"
6"11'-3"
R.O.
5"
6
P
P
4-
6
P
X
6-4X P
3'-8"
3'-10"3'-101 2"
3'
-
2
1
2"
15
'
-
4
3
4"
17'-8"22'-10"
5'-6"22'-10"
17
'
-
0
"
17
'
-
0
"
11
'
-
6
"
14
'
-
3
1
4"
4'
-
2
1
2"
SUPPLY
SWITCH GEAR
4'
-
1
0
"
4'-21 4"7"1"4'-61 4"2"
4"
3'-6"
R.O.
E
A
0
B.2
0
C.7
Z
D
B
B.9
41 2"8'-6"
R.O.
1"
31 2"
2'-0"
1'
-
5
"
1'-0"
4'
-
0
"
6
X
6-
6
PT
X
ABOVE
ABOVE
6X P
2"
M
I
N
.
64'-3"
3'-4"51 2"
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
LL
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Professional of Record:JEFF LIEDERMAN
Kitchen Issue Date:
10
76 E. MITCHELL DR.
PHOENIX, AZ 85012
CONTACT: CHUCK BENNETT
(623) 432-0596
CBENNETT@PMDGINC.COM
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:CB
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
FRAMING PLAN
A1.20
A
1 2 4
A
C
E
1 4
3.2 3.8
F
1
A7.80
2
A7.20
3
A7.20
2
A7.10
1
A7.20
2
A6.10
1
A6.10
1
A7.30
1
A7.70
1
A7.50
1
A6.10
3
A7.10
3 3.70.7
0.6 0.7
0.6
1
A7.10
2
A7.50
Y
1
A7.60
2
A7.60
2
A7.30
1.1
2
A7.70
1 1/4" = 1'-0"
REFLECTED CEILING PLAN
A.REFER TO MECHANICAL DRAWINGS FOR HVAC PLAN, SECTIONS, DUCT SIZES, SUPPLY & RETURN AIR GRILLE
SIZES.
B.REFER TO ELECTRICAL DRAWINGS FOR LIGHTING LAYOUT REQUIREMENTS & ADDITIONAL INFORMATION.
C.REFER TO FINISH SCHEDULE AND SPECIFICATIONS FOR MATERIALS.
D.ALL BLOCKING FOR FIXTURES SUSPENDED FROM CEILING IS SHOWN IN THE FRAMING PLAN.
E.BACK OF HOUSE DIFFUSERS (KITCHEN) TO BE WHITE ENAMEL FINISH. FRONT OF HOUSE DIFFUSERS INSTALLED
IN GYPSUM CEILINGS (FRONT COUNTER AREA, RESTROOM VESTIBULE, RESTROOMS) TO BE ALUMINUM FINISH.
FRONT OF HOUSE RETURN AIR GRILLS TO BE FLAT BLACK PRE-FINISHED ALUMINUM. EXPOSED DUCTWORK TO
BE UNPAINTED GALVANIZED MILL FINISH
F.PROVIDE 2X4 WOOD PURLINS ON FLAT TO TIE DINING ROOM TRUSSES TOGETHER ON TOP OF BOTTOM CHORD.
GC TO COORDINATE SPACING OF PURLINS WITH MECHANICAL INSTALLATION, LIGHTING LAYOUT, DECO CLOUD
ELEMENTS, ETC. PAINT PURLINS TO MATCH TRUSSES (BLACK)
G.CENTER LIGHTS, DIFFUSERS, FANS, ETC. BETWEEN OPEN CEILING TRUSSES. UNLESS OTHERWISE NOTED
H.CENTER DIFFUSERS BETWEEN LIGHTS IN SOLID CEILING CONDITIONS
I.LIGHT FIXTURES IN OPEN CEILING AREA SHALL BE BLACK FINISH
J.LIGHT FIXTURES IN SOLID CEILING AREA, INCLUDING CEILING CLOUDS SHALL BE ANODIZED ALUMINUM FINISH
K.ALL DIFFUSERS IN OPEN CEILING AND SOLID CEILING AREAS SHALL BE MILL FINISH. BOH LAY-IN CEILING
DIFFUSERS SHALL BE WHITE
L.FINISH SPRINKLER HEADS IN OPEN CEILING AREA SHALL BE BLACK FINISH
M.FINISH SPRINKLER HEADS IN SOLID CEILING AREAS SHALL BE CHROME FINISH
N.WOOD CEILING PLANKS SHALL BE INSTALLED AT RANDOM LENGTHS. END JOINT SPACING SHALL BE OFFSET A
MINIMUM OF 12" BETWEEN ADJACENT PLANKS
O.CONTRACTOR TO VERIFY LOCATION OF PENDANT FIXTURES WITH OWNER / ARCHITECT PRIOR TO
INSTALLATION TO ENSURE COORDINATION WITH FURNITURE.
RE: ELEC. & MECH DWGS.
2x4 LED LIGHT
FIXTURE
2x2 LED LIGHT
FIXTURE
LINEAR LIGHT
FIXTURE
DINING CEILING
FAN MOUNT B. O
FAN 9'-0" A.F.F.
RECESSED CAN LIGHT
RECESSED
SQUARE LIGHT
WALL WASH
LIGHT
PENDANT LIGHT -
CEILING LEVEL ALIGN
BOTTOM OF PENDANT
TO B. O. TRUSS FACE
SPUNEC FIXTURE MOUT
7'-5' AFF TO ℄ OF FIXTURE
WALL SCONCE
INTERIOR
OUTDOOR
PENDANT LIGHT.
B. O. PENDANT
9'-0" A.F.F.
HVAC
RETURN AIR
HVAC SUPPLY
DIFFUSER
HVAC
DIFFUSER
FESTOON LIGHTING TO
ATTACH TO CABLE: PART
#HF2-EY90QC ORDER
FROM LIGHTING SUPPLIER,
CABLE TO ATTACH TO
EYELETS SPACED 5' MAX.
BOTTOM OF SWAG 8'-10
EXTENDED
SCONCES
SPOT
LIGHT
ACCESS
HATCHPATIO CEILING FAN
MOUNT
B. O. FAN 9'-6" A.F.F.
EXIT LIGHT
X'-X"
CLG. HT.CEILING HEIGHT
KEY NOTE
ROOM NAME
DETAIL OR
SECTION
DESIGNATION
FINISH TAG
00
A0.00
ROOM NAME
00
XXX-X
EXTERIOR WALL
SCONCE
1.UNDERSIDE METAL DECK REMAIN NATURAL GALVANIZED FINISH
2.CEILING ACCESS
a.CEILING ACCESS DOOR. SEE 10/A8.30
b.CEILING ACCESS PANEL WOOD FINISH TO MATCH & ALIGN WITH ADJACENT CEILING. SEE 9/A8.30
3.ROOF ACCESS HATCH & LADDER. RE: 11/A8.30
4.WINDOW SIGN
5.SHELVING UNITS SUSPENDED FROM CEILING. BLOCKING REQUIRED - SEE SHEETS FS1.10 & FS2.10
6.LIGHT MOUNTED UNDER CABINET TO UPPER SHELF
7.OPEN TRELLIS STRUCTURE. RE: STRUCT. DWG'S.
8.FRONT COUNTER CEILING CLOUD SUPPLIED BY OWNER VIA MILLWORK VENDER, SCHEME "B" FINISH W-3
9.DINING ROOM CEILING CLOUD, SCHEME 'B' FINISH W-2, ALIGN WITH CENTER OF ACCENT TILE
10.MUSIC SPEAKER SHELF PER MILLWORK. PROVIDE BLOCKING IN WALL, REFER TO FOOD SERVICE ELEVATIONS
SHEET FS3.40
11.LINE OF GYP. BULKHEAD. REFER TO INTERIOR ELEVS. FOR FINISH.
12.MENU BOARD CEILING MOUNTED. BLOCKING REQ'D.
13.CEILING MOUNTED DRIVE THRU MONITORS, BLOCKING REQ'D.
14.AWNING BY OTHERS (AGI). G.C. SHALL COORD. WITH STRUCTURAL DWGS, RE: AWNING DWGS
15.EXTERIOR SPEAKERS, RE: EXT. ELEVS. & ELEC. DWGS.
16.STAINLESS STEEL HOOD, UNPAINTED, RE: MECH. DWGS.
17.2x6 WOOD C.J. OR 6"x20 GA. METAL JOIST @ 16" O.C
18.2'x4' ACOUSTIC CEILING PANEL SPACED 8' O.C. PARALLEL TO TRUSSES AND 4' O.C. PERPENDICULAR TO
TRUSSES. PANELS FASTENED TO B.O. ROOF DECK
19.PROVIDE BLCKG. BETWEEN TRUSSES TO SURFACE MOUNT A1E FIXTURE. B.O. BLCKG. 14 1/4" ABOVE B.O.
TRUSS
20.18" MIN. 1-HR FIRE RATED ACOUSTICAL CEILING TILE SYSTEM AROUND HOOD AREA
21.TRUSS, DECKING AT DINING AREA PAINT P-2 (TYP. U.N.O)
22.AIR CURTAIN (MARS LPN2-42) AT SERVICE DOOR 603. REFER TO MECH. DWG'S..
23.AIR CURTAIN AT DRIVE-THRU WINDOWS RE: SPECS. SECT. 08.56.19. MECHANICAL DWGS
24.COOLER LIGHTING BY COOLER MANUFACTURER.
25.5/8" W.R. GYP. BD. CEILING - ATTACH TO BOTTOM OF ROOF TRUSS CHORD.
26.MISTER PUMP HANGER.
27.EXHAUST FAN. RE: MECH. DWG'S.
#
2'x2' ACOUSTICAL CEILING TILE
(WASHABLE). SEE DET.
1,2,5,6,7,15/A1.32
*NOTE: REFER TO CEILING KEYNOTES FOR ADDITIONAL FINISH OPTIONS
CYPRESS WOOD CEILING
PLANKS (SUPPLIED AND
INSTALLED BY G.C.)
GYP. BD CEILING - PAINTED. SEE
DET. 8,9,10/A1.3.2
2'x4' TECTUM ACOUSTIC
CEILING PANEL PAINT P-2
ACT
W-2
ACP
8'-9"
18'-0"
8'
-
8
"
9'-7" AFF
CLOUD 9
20'-0"
6'-0"4'-0"2'-0"4'-0"2'-0"2'-0"4'-0"2'-0"4'-0"
1
A1.31
DRIVE-THRU
PAY
DRIVE-THRU
PICKUP
KITCHEN
DINING
ROOM
SERVING AREA
RESTROOM
VESTIBULE
RESTROOM 1
RESTROOM 3
MECH.
ROOM
FREEZER
COOLER
KITCHEN (BOH)
KITCHEN
2'
-
3
"
1'
-
1
0
"
2'
-
0
"
2'
-
0
"
2'
-
0
"
4'
-
2
"
3'-0"
EQEQ
4'
-
0
"
3'-0"3'-0"3'-0"EQ 3'-5"EQ3'-0"3'-0"EQEQ2'-8"EQ
1'
-
5
"
SUPPLY 1
CUSTOMER PICK UP
2a
W-2
10
15
15
15
2a
9'-0" AFF
CEILING
10'-0" AFF
CEILING
9'-6" AFF
CEILING
9'-6" AFF
CEILING
9'-6" AFF
CEILING
9'-4" AFF
HEADER
12'-2" AFF
CEILING
9'-4" AFF
HEADER
9'-4" AFF
HEADER
10'-0" AFF
CEILING
ACT
6
ACT
ACT
ACT
HOOD UNPAINTED STAINLESS STEEL RE: MECHANICAL
HOOD UNPAINTED
STAINLESS STEEL
RE: MECHANICAL
P-4
P-3
P-3
P-3
P-3
10'-11 1/2" AFF
CEILING
P-1
10'-8" AFF
CEILING
P-2
2a
P-1
P-2
P-4
13
12
5
4'-5"
9'-0" AFF
CEILING
9'-0" AFF
CEILING
3
P-2
8
2'
-
3
"
2'
-
3
"
EQ
EQ
2a
P-3
P-3
1'
-
5
"
12'-2" AFF
CEILING
5
2
A8.30
2
A8.30
8'-0" AFF
HEADER
9'-6" AFF
HEADER
10
12
'
-
3
"
4'
-
6
"
P-11B
ACCENT
TRUSS
4
A8.30
9'-6" AFF
CEILING
5
19
10'-0"
3'
-
0
"
5'
-
0
"
P-2
18
TYP.
6'
-
0
"
EQ
EQ
EQ
EQ
3'-4"2'-3"2'-3"3'-4"
EQ
EQ
EQ
EQ
1'-3"
EQ
EQ
24
TYP.
22
12'-11"
℄ OF WINDOW
3'
-
6
"
23
16
16
4
4
P-4
RESTROOM 2
17
17
17
9'-0" AFF
CEILING
17
TYP.
21
TYP.
20
20
20
20
20
14
23
2
A0.30
1
1
1
MT-1
W-2
26
11
5'
-
6
"
9'
-
3
"
3'
-
3
"
7'-6" AFF
HEADER
3'-111 2"8'-2"8'-2"8'-2"
EQ
5'-0"
EQ
5'-0"
6'
-
2
"
5'
-
0
"
5'
-
0
"
EQ
EQ.EQ.
EQ
EQ
EQ
EQ
7'
-
0
"
7'
-
0
"
EQ
EQ
2'
-
5
1
2"
2'-1"
MANAGER'S
OFFICE
EQEQ
8
A8.30
5'
-
0
"
5
W-2
14
4'-0"
9'
-
0
"
℄ O
F
W
I
N
D
O
W
9'-6"
℄ OF WINDOW
4'
-
0
"
W-2
12-2" AFF
CEILING
12-2" AFF
CEILING
EQ
EQ EQ
12'-2"" AFF
SOFFIT
1'-7"
EQ 5'-0"5'-0"EQ
EQ
EQ
10'-0" AFF
HEADER
SWITCH GEAR
P-3
P-3
4'-0"3'-9"
E
A
0
B.2
0
C.7
Z
2
A6.10
D
B
1
A7.40
B.9
EQ EQ
8'
-
0
"
EQ
8'
-
0
"
9'
-
5
"
EXTERIOR
CORRAL
RCP MATERIAL LEGENDSYMBOL LEGEND
REFLECTED CEILING PLAN LEGEND
REFLECTED CEILING PLAN KEY NOTES
GENERAL NOTES
7
25
25
+12"
A.F.F
+12'-3"
A.F.F
+12'-3"
A.F.F
11'-7"
7
EQ
1
A8.30
EQ
27
3
A7.50
1
A0.13
14
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
LL
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Professional of Record:JEFF LIEDERMAN
Kitchen Issue Date:
10
76 E. MITCHELL DR.
PHOENIX, AZ 85012
CONTACT: CHUCK BENNETT
(623) 432-0596
CBENNETT@PMDGINC.COM
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:CB
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
REFLECTED CEILING
PLAN
A1.30
33
3
A
AA
A
120v
D/T WINDOW
RETURN
1'
-
6
"
120v
3'-10"
120v
4'
-
0
"
120v
10"8"
612"1'-4"
FIXEDOPEN
1 ELEVATION (Drive-Thru Beverage & Ice Area)
3/8"= 1'-0"
FS3.1 2 ELEVATION (Cookline & D/T Pickup)
3/8"= 1'-0"
FS3.1
3 ELEV
3/8"= 1'-0"
FS3.1 5 ELEVATION (Prep)
3/8"= 1'-0"
FS3.14ELEV/Prep
3/8"= 1'-0"
FS3.1 6 ELEV/Prep
3/8"= 1'-0"
FS3.1 7 ELEV/Pay WDW
3/8"= 1'-0"
FS3.1 8 ELEV/Pay WDW
3/8"= 1'-0"
FS3.1 9 ELEV/Pay WDW
3/8"= 1'-0"
FS3.1 10 ELEVATION (Electrical Panels)
3/8"= 1'-0"
FS3.1
11 ELEVATION (Cookline Support Line)
3/8"= 1'-0"
FS3.1 12 ELEVATION (Toast Line)
3/8"= 1'-0"
FS3.1 13 ELEVATION (Bread Rack, Hand Sink, Lockers)
3/8"= 1'-0"
FS3.1
1'
-
6
"
FW-A
4'
-
0
"
9"
HW
1'-0"
6"
4'
-
0
"
6"
4'-9"
5'
-
6
"
5'
-
0
"
4" PVC CHASE FOR COKE
BUNDLE, STUB ABOVE
CEILING, ELBOW AT WALL
PENETRATION ON
DRIVE-THRU SIDE.
4'
-
0
"
2'-4"
2'
-
0
"
1'-10"1'-2"
2'
-
0
"
3'-9"
2'-4"
1'-0"
6'
-
4
"
6'-9"
2'-6"
4" PVC CHASE FOR ICE
CONDENSERS, STUB ABOVE
CEILING, ELBOW AT WALL
PENETRATION ON DRIVE-THRU SIDE
1'-10"1'-8"
6"8"
KDS MONITOR
DIMENSION FROM CORNER AT WALL, TO CLEAR
OPENING IN THE HOOD CANOPY. CONTROL PANEL
WILL EXTEND BEYOND TO THE LEFT
17'-10"
2'-1"
4'
-
6
"
STUB 1.5" E.C. ABOVE CEILING, TO SHARED
BACK OF HOUSE AREA, DOWN TO MUD RING.
(PROVIDE PULL STRING)
5'
-
6
"
9'-33 4"COMM. LINES 3,4 & KP-2; TO OFFICE; PHONE LINE 3
BUMP BAR IN WINDOW RETURN
HOOD ELECTRICAL CONTROL AND ANSUL CABINETS
6"MIN. CLEARANCE EDGE OF COOKING SURFACE TO EDGE OF HOOD
CANOPY (VERIFY CODE)
GAS LINE TO BE PER
DRAWINGS AND ANY CODES
4"
CLEAR OPEN AREA OF CANOPY
CONTROL/ANSUL/ELECTRIAL PANEL FOR HOOD. ALL HOOD PLACEMENT DIMENSIONS ARE
TO OPEN PART OF CANOPY (VERIFY WHICH END(S) THIS UNIT IS INSTALLED ON)6"
STUB 1.5" E.C. ABOVE CEILING, THEN DOWN TO MUD RING. (PROVIDE PULL STRING)3/4" GALVANIZED GREASE DISPOSAL PIPING
STUBBED TO ACTUAL OR FUTURE PLANNED
LOCATION. NEED TO LEAVE CLEARANCE FOR 4"
COVER OVER PIPE. (VERIFY WITH OWNER)
7'-11"6"
1'
-
6
"
6"
KDS MONITOR
GAS LINE
1'
-
0
"
3'-3"3'-7"
9"9"
2'
-
0
"
1'
-
6
"
3'-3"3'-3"
DARPRO LINE
2'-6"
6'
-
0
"
1'
-
6
"
3'-6"
9"8"
STUB JBOX & 3 4" E.C. IN
DRYWALL WINDOW
RETURN, ABOVE CEILING
FOR MICROPHONE
4'
-
6
"
4'
-
6
"
1'-3"
4'
-
6
"
DUPLEX RECEPTACLE, INSIDE 8X8 BOX,
TO FACE LENGTH OF 8X8 BOX.
8x8 J-BOX, WITH (1) 2" RIGID CONDUIT FOR
WIRELESS BASE (HME) (STUB ABOVE CEILING)
5'
-
0
"
STUB 1-1/2" E.C. ABOVE CEILING
AND DOWN TO TWO MUD RINGS.
(PROVIDE PULL STRING(S)).
6'
-
0
"
1'-2"6"
7'-1"
2'
-
3
"
1'-11"4"
DRIVE-THRU MONITOR
(SHARED)
STUB 1-1/2" E.C. ABOVE
CEILING, DOWN TO TWO MUD
RINGS FOR DATA TO EACH
REGISTER AND MONITOR ON
WALL
STUB 3 4" E.C. ABOVE CEILING
OUT TO DRIVE-THRU SPEAKER
POST FOR WIRING AND LOOP
DETECTOR (PROVIDE PULL
STRING)
OUTLET FOR WIRELESS HEADSET
CHARGING
7'
-
6
"
1'-8"
1'
-
6
"
DRIVE-THRU CANOPY BACKLIT
SWITCH (S)
STUB 1 1/2" E.C. ABOVE CEILING
OUT TO CANOPY AMENITIES
(PROVIDE PULL STRING)
6"
2'-9"
2'
-
0
"
CEILING DUPLEX RECEPTACLE AT CEILING
MONITOR POST SUPPORT
BLOCKING NEEDED FOR
MOUNTING POST
5'-6"
HOOD
6"
7'
-
0
"
4"1'-4"
3'-9"
1'-6"
7'
-
0
"
8'
-
6
"
GREASE DISPOSAL REMOTE CONTROL
PANEL UNIT AND HARNESS BY OTHERS.
30 FT. LATERAL DISTANCE FROM
DISPOSAL TANK
6'
-
6
"
KDS
STUB 1.5" E.C. ABOVE CEILING, THEN DOWN TO MUD RING. (PROVIDE PULL STRING)
6'
-
0
"
1'
-
6
"
4'
-
2
"
6"5"
6"7"
1'
-
6
"
1'-0"
4"
6"
1'
-
6
"
1'-3"
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
LL
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Professional of Record:JEFF LIEDERMAN
Kitchen Issue Date:
10
76 E. MITCHELL DR.
PHOENIX, AZ 85012
CONTACT: CHUCK BENNETT
(623) 432-0596
CBENNETT@PMDGINC.COM
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:CB
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
EQUIPMENT
ELEVATIONS
FS3.20
2
3
A
3'
-
6
"
120v
2'-4"
HW CW
1'
-
6
"
120v
FW-A
4'
-
0
"
3'-5"
8"
120v
3'
-
6
"
5'
-
6
"
1'
-
1
0
"
TW
O
D
R
A
W
E
R
L
A
T
E
R
A
L
FI
L
E
W
I
T
H
S
T
O
R
A
G
E
CA
B
I
N
E
T
A
B
O
V
E
SHELVING
SHELVING
6'
-
9
"
1'-7"
120v
10
'
-
0
"
PHONE LINES
(1 & 2)
4'
-
0
"
1'
-
6
"
MONI
T
O
R
MONI
T
O
R
PRINTER
SAFE
DESK
6'
-
1
0
"
10"3'-1"1'-7"
8"4"
1'-0"8"8"
PHONE LINES
(3 & 4)
120v(IG)
120v(IG)
DUPLEX NOT
ISOLATED
GROUND
CAT-5
120v(IG)
OV
E
R
H
E
A
D
S
H
E
L
V
I
N
G
U
N
I
T
1" CONDUIT ABOVE
CEILING
4'
-
6
"
9'
-
6
"
4'-8"
3'-9"
TYCO
BOX
TRANSMITTER
6"
8"
9'
-
6
"
120v 120v
120v
6"
120v
3'
-
8
"
8'
-
6
"
8'
-
1
0
"
LIGHT
LIGHT
120v
SINGLE RECEPTACLE
AND DEDICATED
CIRCUIT FOR SAFE
1'-8"
(3) DOUBLE GANG J-BOX(S) BOXES
FOR MUSIC ATTENUATOR(S)
21 ELEVATION (Prep)
3/8"= 1'-0"
FS3.1 22 ELEVATION (Office)
3/8"= 1'-0"
FS3.1 23 ELEVATION (Office)
3/8"= 1'-0"
FS3.1 24 ELEVATION (Office)
3/8"= 1'-0"
FS3.1 25 ELEVATION (Office)
3/8"= 1'-0"
FS3.1 26 ELEVATION (Cane's Gear)
3/8"= 1'-0"
FS3.1
HW
4'
-
0
"
6"
HOSE BIB, HOT
WATER, FOR
CHEMICAL SYSTEM
DISPENSER
HW CW
2'-6"
3'
-
0
"
HW CW
5'-2"10"
1'
-
6
"
14
.
5
"
CL
E
A
R
1'
-
0
"
4'
-
0
"
1'
-
6
"
1'
-
6
"
2'
-
0
"
3" PVC CHASE BETWEEN WALL FROM UNDER COUNTER THRU
WALL TO END OF CABINET ON OTHER SIDE. (KETCHUP LINES)
17 ELEV (Mop)
3/8"= 1'-0"
FS3.1 18 ELEV (Mop)
3/8"= 1'-0"
FS3.1 20 ELEVATION (3-Compartment Sink)
3/8"= 1'-0"
FS3.1
TWO 8"X8"X4" PLYWOOD BOXES WRAPPED IN FRP, STRAPPED/MOUNTED
TO WALL FOR COKE BUNDLED SYRUP LINES. INSTALL LASCO FITTINGS
INC. #9851040 SCH80C SOLID STYLE SLIP 4" FLANGE
6'
-
8
"
1'-6"
9'
-
3
"
1'-0"6"
12
0
v
2'-0"
NOTE:
PUMPS TO BE MOUNTED
ON WALL AND NOT ON
RACK.
FW-A
FW-A
19 ELEVATION (Soda Bib Racks)
3/8"= 1'-0"
FS3.1
9'
-
0
"
7'
-
1
0
"
120v
1'
-
6
"
120v120v
FW-A
2'-2"
1'-6"8"
15 ELEVATION (Pickup WDW POP & 3rd Board)
3/8"= 1'-0"
FS3.1
7'
-
0
"
7'
-
6
"
16 ELEVATION (Cooler Door, Dry Storage, & Rear Door)
3/8"= 1'-0"
FS3.1
7'
-
6
"
J-BOXES FOR
THERMOSTATS
5'
-
6
"
J-BOXES FOR GFCI OVERRIDES FOR EQUIP
UNDER THE HOOD (CONFIRM NUMBER
NEEDED)
4'
-
1
0
"
3'
-
6
"
6"
9"
STUB 3 4" E.C. ABOVE CEILING
S/S COVER PLATE, SWITCH BANK FOR BOH 3-WAY & PILOT LIGHT INTERIOR
SIGN(S) SWITCH.
DECORA S/S COVER PLATE, SWITCH BANK FOR LOBBY FAN(S) SHARED CONTROLLER,
PATIO FAN(S) SHARED CONTROLLER, AND LOBBY NIGHT LIGHT CONTROLLER
VOLUME CONTROLS
DOUBLE GANG BOX FOR LOBBY ATTENUATOR
S/S DECORA COVER PLATE
14 ELEVATION (Office Wall & Dining Board)
3/8"= 1'-0"
FS3.1
6'
-
6
"
1'-512"
HOLD
ALL
CUBBIES
1'
-
6
"
10"
BUMP BAR
5'-4"
4'
-
0
"
BUMP BAR
1'
-
6
"
STUB 1.5" E.C. ABOVE CEILING, THEN DOWN TO
MUD RING. (PROVIDE PULL STRING)
6'
-
0
"
2'-3"2'-1"
6"
4'
-
6
"
D/T WINDOW
RETURN
612"
1'
-
6
"
1'-9"
6'
-
6
"
6"
POWER AND DATA ON THIS SOFFIT VERTICAL SURFACE NEAR END
OF PIPE SHELVING UNIT., RUN POWER CORD AND DATA LINE OVER
AND DOWN PIPE TO END PANEL OF WOODEN BOX, TO KDS
4"1'-4"
BUMP BAR AT FRONT
EDGE OF SHELF
CEILING DUPLEX RECEPTACLE AT CEILING MONITOR
POST SUPPORT.
BLOCKING NEEDED FOR MOUNTING POST.
CEILING DATA JBOX AT CEILING MONITOR POST
SUPPORT
KITCHEN 3-WAY LIGHT SWITCH
SINGLE GANG BOX WITH CONDUIT CHASE STUBBED TO
CEILING ABOVE, FOR SECURITY KEYPAD WIRINGJ-BOX FOR DOOR BELL ON THE
EXTERIOR SIDE OF THIS WALL
ANSUL PULL STATION (SHOWN SURFACE
MOUNTED, CAN BE IN THE WALL)
J-BOX ON THIS SIDE OF WALL FROM EXTERIOR
DOOR BELL BELOW, FOR SURFACE MOUNTED
BELL, THEN CONDUIT CONTINUED TO CEILING
ABOVE
J-BOX ABOVE CEILING, TO POWER TRANSFORMER
TO DETEX PANIC BAR ALARM AND FOR
TRANSFORMER TO DOOR BELL
5'
-
0
"
3'
-
0
"
4'
-
0
"
3'
-
6
"
METAL FLAP DOOR, AT BOTH
VISION WINDOWS, HINGED AT TOP
6"
6"
1'
-
7
"
PROVIDE BLOCKING ABOVE DOOR
FOR OPTIONAL FLY FAN, MARS MODEL
LPN248-1UA-OB. VERIFY INSTALLATION
OF FAN WITH OWNER
CONDUIT FROM DEXTEX PANIC BAR
ALARM TO DOOR CONTACT LOCATION,
6" FROM EDGE OF DOOR
J-BOX FOR DOOR BELL ON THE EXTERIOR
SIDE OF THIS WALL
6"
MUD RING FOR
NETWORK ROUTER
NETWORK
ROUNTER
9'
-
0
"
CW FW-A FW-B
1'-6"1'-0"4'-0"
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
LL
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Professional of Record:JEFF LIEDERMAN
Kitchen Issue Date:
10
76 E. MITCHELL DR.
PHOENIX, AZ 85012
CONTACT: CHUCK BENNETT
(623) 432-0596
CBENNETT@PMDGINC.COM
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:CB
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
EQUIPMENT
ELEVATIONS
FS3.30
3
3
3
A
1355 E Cooley Dr, Ste C
Colton, CA 92324
P (909) 824-7311
Terracon.com
January 28, 2025
Raising Cane's Restaurants, LLC
800 Bishop Road, Suite 210
Plano, TX 75024-4274
Attn: Ms. Kristen Roberts
E: KRoberts@raisingcanes.com
P: (972) 769-3348
Re: Plan Review Letter
RC# 1032 - Santa Ana
1303 N Bristol St
Santa Ana, California
Terracon Project Number CB235017
Dear Ms. Roberts:
At the request of Sara Emami from PM Design, on your behalf, Terracon has prepared
this letter to document our review of the structural plans prepared for the proposed
project.
References:
1.“Raising Cane’s Restaurant #C1032”, 1303 N. Bristol St., Santa Ana, CA 92706, P6E-
HV Scheme B, Sheets S0.1, S0.4, S0.5, S0.8, S1.1, S3.1 S4.1, S4.2, S4.3, S6.1, and
S6.2, prepared by Wright Structural Engineers, dated July 1, 2024, building
resubmittal date of January 20, 2025.
2.“Geotechnical Engineering Report”, Raising Cane’s Restaurant (RC-1032) – Santa
Ana, Terracon Project Number CB235017, prepared by Terracon, dated March 23,
2023.
It is our opinion that the geotechnical recommendations presented in our geotechnical
engineering report (Reference 2) appear to have generally been incorporated into the
referenced plan sheets cited above (Reference 1).
The referenced documents have been reviewed for Geotechnical aspects only. We make
no representation regarding accuracy of dimensions, quantities, measurement,
calculations or any portion of the design not related to the geotechnical aspects of this
project.
Plan Review Letter
RC# 1032 - Santa Ana | Santa Ana, California
January 28, 2025 | Terracon Project Number CB235017
Facilities |Environmental |Geotechnical | Materials 2
If you have any inquiries or comments regarding this letter, please do not hesitate to
contact the undersigned at your convenience.
Sincerely,
Terracon Consultants, Inc.
Phillip Penrose, P.E.
Project Engineer
1 2 4
1 4
3.2 3.8
3 3.70.7
0.6 0.7
0.6 1.1
DRIVE-THRU
PAY DRIVE-THRU
PICKUP
DINING ROOM
SERVING AREA
CUSTOMER PICK UP
RESTROOM
VESTIBULE
RESTROOM 1
RESTROOM 3
MECH.
ROOM
FREEZER
COOLER
EXTERIOR CORRAL
KITCHEN (BOH)
KITCHEN
RESTROOM 2
SUPPLY
SWITCH GEAR
OFFICE
UTILITY
CABINET.
24
X
1
8
X
8
.
6
2
B
O
X
UTILITY
CABINET.
§
U.L. LISTED RECESSED ROUND LED
FIXTURE AND LED LIGHT.
9"
§
U.
L
.
L
I
S
T
E
D
R
E
C
E
S
S
E
D
R
O
U
N
D
L
E
D
FI
X
T
U
R
E
A
N
D
L
E
D
L
I
G
H
T
.
E
A
0
B.2
0
C.7
Z
D
B
B.9
MECHANICAL SYMBOL SCHEDULE2
KEYNOTES3
A
C
E
F
Y
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
M1.1
HVAC FLOOR PLAN
1 HVAC FLOOR PLAN
1/4"= 1'-0"
A
A
A
A
4 MOUNTED EXHAUST FAN
N.T.S.
CURB MOUNTING FOR ROOF-
ROOFTOP UNIT
5 SUPPORT AND DRAIN DETAIL
N.T.S.
3 ROUND DUCT BRANCH RUNOUT CONNECTION DETAIL
N.T.S.
2 ROOFTOP UNIT DETAIL
N.T.S.
8 OUTDOOR AIR REQUIREMENTS - 2022 CMC
7 AIR BALANCE SCHEDULE
N.T.S.
SPIRAL DUCT SUPPORT6
FOR RR EXHAUST TO RTU-110N.T.S.
LOW VOLTAGE THERMOSTAT WIRING DIAGRAM
9 AIR CURTAIN SCHEDULE
1 MECHANICAL EQUIPMENT SCHEDULES
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
M2.1
HVAC SCHEDULES
AND DETAILS
A
1 WALL CANOPY KITCHEN HOOD1 DETAIL
N.T.S.
3 HOOD EXHAUST FAN / MAKE-UP AIR UNIT DETAILS
N.T.S.
2 WALL CANOPY KITCHEN HOOD2 DETAIL
N.T.S.
14' 6"NOM./14' 6.00"OD.
16'-6.00" OVERALL LENGTH
54"
12"
UTILITY
CABINET.
24
X
1
8
X
8
.
6
2
B
O
X
12"
UTILITY
CABINET.
2"
24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"12"12"
18"
24 3/4"
9"
12"
24"
49 1/2"
9"
12"
24"
49 1/2"
9"
12"
24"
49 1/2"
9"
12"
24"
LIGHTING FOR ACPSP JOB # 6950327 - HOOD #1
INPUT: 120V AC, 1 PHASE, 50/60HZ, 3.5 WATTS PER LIGHT.
TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH, WIRE PER
HOOD ELECTRICAL CONTROL PANEL SCHEMATIC.
TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH, WIRE
BLACK AND WHITE WIRE TO A 120VAC SERVICE.
END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM
J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY.
1" LAYER OF INSULATION FACTORY
INSTALLED IN INTERNAL BACK STANDOFF.
MEETS 0 INCH REQUIREMENTS FOR
CLEARANCE TO COMBUSTIBLE SURFACES.
3"
§
40 15/16"
12"
Ø14"
90 1/16"43"
12"
Ø14"
U.L. LISTED RECESSED ROUND LED
FIXTURE AND LED LIGHT.
1"
1.00" WIDE INSULATED
BACKSPLASH 122.00" HIGH
X 234.00" LONG.
NOTE: ADDITIONAL HANGING ANGLES PROVIDED FOR HOODS 12' AND LONGER.
5' 6"NOM./5' 6.00"OD.
54"
2"
21"21"12"12"
18"
33"
9"
12"
28"
LIGHTING FOR ACPSP JOB # 6950327 - HOOD #2
INPUT: 120V AC, 1 PHASE, 50/60HZ, 3.5 WATTS PER LIGHT.
TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH, WIRE PER
HOOD ELECTRICAL CONTROL PANEL SCHEMATIC.
TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH, WIRE
BLACK AND WHITE WIRE TO A 120VAC SERVICE.
END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM
J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY.
1" LAYER OF INSULATION FACTORY
INSTALLED IN INTERNAL BACK STANDOFF.
MEETS 0 INCH REQUIREMENTS FOR
CLEARANCE TO COMBUSTIBLE SURFACES.
3"
§
33"33"
12"
Ø10"
U.L. LISTED RECESSED ROUND LED
FIXTURE AND LED LIGHT.
1"
1.00" WIDE INSULATED
BACKSPLASH 122.00" HIGH
X 66.00" LONG.
1" LAYER OF INSULATION FACTORY
INSTALLED IN 3" INTERNAL STANDOFF.
MEETS 0 INCH REQUIREMENTS FOR
CLEARANCE TO COMBUSTIBLE SURFACES.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§EXHAUST RISER.
HANGING ANGLE.
RECESSED ROUND LED FIXTURE AND LED LIGHT,
3500 K WARM OUTPUT.
23.5% OPEN STAINLESS
STEEL PERFORATED PANEL.
ATTACHING PLATES.
SUPPLY RISER WITH
VOLUME DAMPER.
6"
2 3/4"
14"
LED.
18"
1.00" WIDE INSULATED
BACKSPLASH 122.00" HIGH
X 234.00" LONG.
FIELD WRAPPER 8.00" HIGH
(SEE HOOD OPTIONS TABLE).
1" LAYER OF INSULATION FACTORY INSTALLED
ON TOP OF HOOD. MEETS 0 INCH
REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE
SURFACES.
23"
23"
LEFT AND RIGHT QUARTER END PANELS.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"1"
55"
*6"
*6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING.
*6" CLEARANCE ABOVE HOOD
REQUIRED FOR FIRE SYSTEM PIPING.
*24"
*24" CLEARANCE ABOVE HOOD
RECOMMENDED FOR SERVICEABILITY.
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" CAPTRATE SOLO
FILTER WITH HOOK.
1" LAYER OF INSULATION FACTORY
INSTALLED IN 3" INTERNAL STANDOFF.
MEETS 0 INCH REQUIREMENTS FOR
CLEARANCE TO COMBUSTIBLE SURFACES.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§EXHAUST RISER.
HANGING ANGLE.
RECESSED ROUND LED FIXTURE AND LED LIGHT,
3500 K WARM OUTPUT.
23.5% OPEN STAINLESS
STEEL PERFORATED PANEL.
ATTACHING PLATES.
SUPPLY RISER WITH
VOLUME DAMPER.
6"
2 3/4"
14"
LED.
18"
1.00" WIDE INSULATED
BACKSPLASH 122.00" HIGH
X 66.00" LONG.
FIELD WRAPPER 8.00" HIGH
(SEE HOOD OPTIONS TABLE).
1" LAYER OF INSULATION FACTORY INSTALLED
ON TOP OF HOOD. MEETS 0 INCH
REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE
SURFACES.
23"
23"
LEFT AND RIGHT QUARTER END PANELS.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"1"
55"
*6"
*6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING.
*6" CLEARANCE ABOVE HOOD
REQUIRED FOR FIRE SYSTEM PIPING.
*24"
*24" CLEARANCE ABOVE HOOD
RECOMMENDED FOR SERVICEABILITY.
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" CAPTRATE SOLO
FILTER WITH HOOK.
M3.1
KITCHEN HOOD DETAILS
AND HVAC SPECS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
Louisiana Office
REGION 27
PHONE: (985) 781 - 4107
EMAIL: reg27@captiveaire.com
FOR QUESTIONS, CALL THE
1
2
KH-1
KH-2
5424
ND-2-PSP-F
5424
ND-2-PSP-F
CAPTIVEAIRE
CAPTIVEAIRE
14' 6"
5' 6"
600
DEG
450
DEG
I
I
HEAVY
MEDIUM
225
175
3262
962
4"
4"
4"
14"
14"
10"
1631
1631
962
1526
1526
1764
-0.636"
-0.636"
-0.504"
2544
770
430 SS
WHERE EXPOSED
430 SS
WHERE EXPOSED
ALONE
ALONE
ALONE
ALONE
HOOD
NO TAG MODEL MANUFACTURER LENGTH
MAX
COOKING
TEMP
TYPE APPLIANCE
DUTY
DESIGN
CFM/FT
TOTAL
EXH CFM
EXHAUST PLENUM
RISER(S)
WIDTH LENG HEIGHT DIA CFM VEL SP
TOTAL
SUPPLY
CFM
HOOD
CONSTRUCTION
HOOD CONFIG
END TO
END ROW
1
2
KH-1
KH-2
CAPTRATE SOLO FILTER
CAPTRATE SOLO FILTER
10
4
20"
20"
16"
16"
85% SEE FILTER SPEC
85% SEE FILTER SPEC
9
4
RECESSED ROUND
RECESSED ROUND
NO
NO
LEFT
RIGHT
12"x54"x24"
12"x54"x24"
TANK FS
TANK FS
4.0
4.0
SC-311110MA
1 LIGHT
1 FAN YES
YES
1627
LBS
446
LBS
HOOD
NO TAG
FILTER(S)
TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS
LIGHT(S)
QTY TYPE WIRE
GUARD
UTILITY CABINET(S)
LOCATION SIZE
FIRE SYSTEM
TYPE SIZE
ELECTRICAL
MODEL #
SWITCHES
QUANTITY
FIRE
SYSTEM
PIPING
HOOD
HANGING
WEIGHT
1
2
KH-1
KH-2
FIELD WRAPPER 8.00" HIGH FRONT, LEFT, RIGHT.
BACKSPLASH 122.00" HIGH X 234.00" LONG X 1.00" WIDE INSULATED 430 SS VERTICAL.
RIGHT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS.
LEFT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS.
INSULATION FOR TOP OF HOOD.
STRUCTURAL FRONT PANEL.
INSULATION FOR BACK OF HOOD.
RISER SENSOR INSTALL 6IN PLEN.
FULL DIMENSION HANGING BRACKET - FRONT.
FIELD WRAPPER 8.00" HIGH FRONT, LEFT, RIGHT.
BACKSPLASH 122.00" HIGH X 66.00" LONG X 1.00" WIDE INSULATED 430 SS VERTICAL.
RIGHT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS.
LEFT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS.
INSULATION FOR TOP OF HOOD.
INSULATION FOR BACK OF HOOD.
RISER SENSOR INSTALL 6IN PLEN.
HOOD
NO TAG OPTION
1
2
KH-1
KH-2
Front
Front
198"
66"
18"
18"
6"
6"
MUA
MUA
MUA
MUA
MUA
12"
12"
12"
12"
12"
24"
24"
24"
24"
28"
636
636
636
636
770
0.181"
0.181"
0.181"
0.181"
0.178"
HOOD
NO TAG POS LENGTH WIDTH HEIGHT TYPE
RISER(S)
WIDTH LENG DIA CFM SP
1500500
FLOW RATE (CFM)
1000
0.00
0
0.50
PR
E
S
S
U
R
E
D
R
O
P
(
i
n
.
H
2
0
)
PRESSURE DROP VS. FLOW RATE
RRSPECIFICATION: CAPTRATE GREASE-STOP SOLO FILTER
A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN,
THE CAPTRATE GREASE-STOP SOLO FILTER IS A SINGLE-STAGE FILTER FEATURING
LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE.
FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD
GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE
PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND
COMPONENTS WHEN ASSEMBLED.
2-INCH DEEP HOOD CHANNEL(S).
TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY.
UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO
FR
A
C
T
I
O
N
A
L
E
F
F
I
C
I
E
N
C
Y
(
%
)
0
0.1
20
40
1.0
PARTICLE DIAMETER (UM)
10.0
EFFICIENCY VS. PARTICLE DIAMETER
60
80
100
THE CAPTRATE GREASE-STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05.
TE
A
NSF ACCORDANCE
No. 96
NFPA
WITH
BUILT
IN
SLI DTE
RO
CH
B
N
RAN I,OR M
.
YR
OR
LAIGNTSB
AT
CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:.
NFPA #96.
NSF STANDARD #2.
UL STANDARD #1046.
INT. MECH. CODE (IMC).
ULC-S649.
1.00
1.50
2.00
2.50
3.00
3.50
MANUFACTURER APPROVED FOR USE IN SOLID FUEL APPLICATIONS AS A SPARK ARRESTER.
GREASE DUCT & CHIMNEY SPECIFICATIONS:
PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW"
ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW"
IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING
CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW"
DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER
THE MANUFACTURES INSTALLATION GUIDE.
PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER
MANUFACTURES LISTING MODEL "DW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" PER 12",
HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12".
DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN
HORIZONTAL RUNS.
IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT
LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL
"DW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE
430 STAINLESS OUTER SHELL.
§
CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF
LISTED, PRE-FABRICATED ROUND GREASE EXHAUST
DUCT TO REDUCE STATIC PRESSURE IN THE SYSTEM,
MINIMIZE INSTALLATION AND INSPECTION TIMES, AND
ENSURE DUCT IS LIQUID TIGHT
CUSTOMER APPROVAL TO MANUFACTURE:
___' - ___"
VERIFY CEILING HEIGHT
HVAC DISTRIBUTION NOTE
HIGH VELOCITY DIFFUSERS OR HVAC RETURNS SHOULD
NOT BE PLACED WITHIN TEN (10) FEET OF THE EXHAUST
HOOD. PERFORATED DIFFUSERS ARE RECOMMENDED.
PATENT NUMBERS
AC-PSP WALL (CANADA) - CA PATENT 2820509.
AC-PSP (UNITED STATES) - US PATENT 7963830 B2.
AC-PSP ISLAND (CANADA) - CA PATENT 2520330.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
MARVIN BORDELON
FOR QUESTIONS, CALL
FAX: (919) 747-5637, REG27@CAPTIVEAIRE.COM
REGION 27
59040 Amber Street Ste B, Slidell, LA 70461
PHONE: (985) 781-4107
ALL SPECIFIERS & CONTRACTORS SHOULD CONTACT
REG27 CAPTIVE AIRE OFFICE TO COORDINATE
PROPER INTEGRATION OF KITCHEN VENTILATION
SYSTEM FOR PROJECT
NATIONAL ACCOUNT
M3.3
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
14' 6"NOM./14' 6.00"OD.
16'-6.00" OVERALL LENGTH
54"
12"
UTILITY
CABINET.
24
X
1
8
X
8
.
6
2
B
O
X
12"
UTILITY
CABINET.
2"
24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"12"12"
18"
24 3/4"
9"
12"
24"
49 1/2"
9"
12"
24"
49 1/2"
9"
12"
24"
49 1/2"
9"
12"
24"
LIGHTING FOR ACPSP JOB # 6950327 - HOOD #1
INPUT: 120V AC, 1 PHASE, 50/60HZ, 3.5 WATTS PER LIGHT.
TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH, WIRE PER
HOOD ELECTRICAL CONTROL PANEL SCHEMATIC.
TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH, WIRE
BLACK AND WHITE WIRE TO A 120VAC SERVICE.
END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM
J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY.
1" LAYER OF INSULATION FACTORY
INSTALLED IN INTERNAL BACK STANDOFF.
MEETS 0 INCH REQUIREMENTS FOR
CLEARANCE TO COMBUSTIBLE SURFACES.
3"
§
40 15/16"
12"
Ø14"
90 1/16"43"
12"
Ø14"
U.L. LISTED RECESSED ROUND LED
FIXTURE AND LED LIGHT.
1"
1.00" WIDE INSULATED
BACKSPLASH 122.00" HIGH
X 234.00" LONG.
NOTE: ADDITIONAL HANGING ANGLES PROVIDED FOR HOODS 12' AND LONGER.
5' 6"NOM./5' 6.00"OD.
54"
2"
21"21"12"12"
18"
33"
9"
12"
28"
LIGHTING FOR ACPSP JOB # 6950327 - HOOD #2
INPUT: 120V AC, 1 PHASE, 50/60HZ, 3.5 WATTS PER LIGHT.
TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH, WIRE PER
HOOD ELECTRICAL CONTROL PANEL SCHEMATIC.
TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH, WIRE
BLACK AND WHITE WIRE TO A 120VAC SERVICE.
END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM
J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY.
1" LAYER OF INSULATION FACTORY
INSTALLED IN INTERNAL BACK STANDOFF.
MEETS 0 INCH REQUIREMENTS FOR
CLEARANCE TO COMBUSTIBLE SURFACES.
3"
§
33"33"
12"
Ø10"
U.L. LISTED RECESSED ROUND LED
FIXTURE AND LED LIGHT.
1"
1.00" WIDE INSULATED
BACKSPLASH 122.00" HIGH
X 66.00" LONG.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUT.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUTS.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL ALL-THREAD.
HOOD CORNER
HANGING ANGLE
(WEIGHT BEARING
ANCHOR POINT
FOR HOOD).
HOOD CORNER
HANGING ANGLE
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUTS.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
ASSEMBLY INSTRUCTIONS
HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5
(MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING
ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS
AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE
DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING
ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED
THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57
FT-LBS.
(HARDWARE BY INSTALLER)
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUT.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
FULL LENGTH
HANGING ANGLE
(WEIGHT BEARING
ANCHOR POINT
FOR HOOD).
FULL LENGTH
HANGING ANGLE
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL ALL-THREAD.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUTS.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUT.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
ASSEMBLY INSTRUCTIONS
HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5
(MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING
ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS
AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE
DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS.
SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR
FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED
THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57
FT-LBS.
(HARDWARE BY INSTALLER)
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUT.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
SUPPLY PLENUM
HANGING ANGLE
(WEIGHT BEARING
ANCHOR POINT
FOR SUPPLY
PLENUM).
SUPPLY PLENUM
HANGING ANGLE
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL ALL-THREAD.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUTS.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
1/2" - 13 TPI
GRADE 5 (MINIMUM)
STEEL HEX NUT.
1/2" GRADE 5
(MINIMUM) STEEL
FLAT WASHER.
ASSEMBLY INSTRUCTIONS
HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5
(MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING
ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS
AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE
DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS.
SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR PSP
HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH
BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS.
(HARDWARE BY INSTALLER)
HOODS #SURFACE *CLEARANCE
1
TOP 0"
FRONT 0"
BACK 0"
LEFT 0"
RIGHT 0"
2
TOP 0"
FRONT 0"
BACK 0"
LEFT 18"
RIGHT 18"
- *0" CLEARANCE TO COMBUSTIBLES CONFORMS TO UL710
STANDARD.
- HOOD MOUNTED UTILITY CABINETS REQUIRE 36" SERVICE
CLEARANCE.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.4
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
1" LAYER OF INSULATION FACTORY
INSTALLED IN 3" INTERNAL STANDOFF.
MEETS 0 INCH REQUIREMENTS FOR
CLEARANCE TO COMBUSTIBLE SURFACES.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§EXHAUST RISER.
HANGING ANGLE.
RECESSED ROUND LED FIXTURE AND LED LIGHT,
3500 K WARM OUTPUT.
23.5% OPEN STAINLESS
STEEL PERFORATED PANEL.
ATTACHING PLATES.
SUPPLY RISER WITH
VOLUME DAMPER.
6"
2 3/4"
14"
LED.
18"
1.00" WIDE INSULATED
BACKSPLASH 122.00" HIGH
X 234.00" LONG.
FIELD WRAPPER 8.00" HIGH
(SEE HOOD OPTIONS TABLE).
1" LAYER OF INSULATION FACTORY INSTALLED
ON TOP OF HOOD. MEETS 0 INCH
REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE
SURFACES.
23"
23"
LEFT AND RIGHT QUARTER END PANELS.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"1"
55"
*6"
*6" CLEARANCE ABOVE HOOD
REQUIRED FOR FIRE SYSTEM PIPING.
*6" CLEARANCE ABOVE HOOD
REQUIRED FOR FIRE SYSTEM PIPING.
*24"
*24" CLEARANCE ABOVE HOOD
RECOMMENDED FOR SERVICEABILITY.
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" CAPTRATE SOLO
FILTER WITH HOOK.
1" LAYER OF INSULATION FACTORY
INSTALLED IN 3" INTERNAL STANDOFF.
MEETS 0 INCH REQUIREMENTS FOR
CLEARANCE TO COMBUSTIBLE SURFACES.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§EXHAUST RISER.
HANGING ANGLE.
RECESSED ROUND LED FIXTURE AND LED LIGHT,
3500 K WARM OUTPUT.
23.5% OPEN STAINLESS
STEEL PERFORATED PANEL.
ATTACHING PLATES.
SUPPLY RISER WITH
VOLUME DAMPER.
6"
2 3/4"
14"
LED.
18"
1.00" WIDE INSULATED
BACKSPLASH 122.00" HIGH
X 66.00" LONG.
FIELD WRAPPER 8.00" HIGH
(SEE HOOD OPTIONS TABLE).
1" LAYER OF INSULATION FACTORY INSTALLED
ON TOP OF HOOD. MEETS 0 INCH
REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE
SURFACES.
23"
23"
LEFT AND RIGHT QUARTER END PANELS.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"1"
55"
*6"
*6" CLEARANCE ABOVE HOOD
REQUIRED FOR FIRE SYSTEM PIPING.
*6" CLEARANCE ABOVE HOOD
REQUIRED FOR FIRE SYSTEM PIPING.
*24"
*24" CLEARANCE ABOVE HOOD
RECOMMENDED FOR SERVICEABILITY.
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" CAPTRATE SOLO
FILTER WITH HOOK.
1"
COMBUSTIBLE WALL
LENGTH
- STAINLESS STEEL BACKSPLASH INSULATED WITH 1" THICK
DUCTBOARD WITH FOIL BACKING.
- INSULATED BACKSPLASH REQUIRES APPLIANCES WITH
CLEARANCE TO COMBUSTIBLES REQUIREMENTS TO BE
MOUNTED A MINIMUM OF 6" OFF OF THE COMBUSTIBLE WALL.
-HOOD REAR INSULATION MUST BE UTILIZED WITH INSULATED.
BACKSPLASH, UNLESS INSULATED BACKSPLASH EXTENDS TO
TOP OF HOOD.
SLIDE TOP FLANGE BEHIND LOWER
REAR EDGE OF HOOD UNLESS
LOCAL JURISDICTION REQUIRES
EXTENDED BACKSPLASH
FLANGES LOCATED
AT TOP AND BOTTOM
HEIGHT
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.5
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
1
2
TANK FS
PCU TANK
4.0
4.0/4.0/4.0
4.0/4.0/4.0
20
60
36
62
28
FIRE CABINET LEFT
FIRE CABINET RIGHT
PCU UTILITY CABINET
LEFT, HOOD 1
RIGHT, HOOD 1
N/A
FIRE
SYSTEM
NO
TAG TYPE SIZE MAX FP DESIGN
FP
INSTALLATION
SYSTEM LOCATION ON HOOD
1 SC ELECTRICAL 2.500 CAPTIVEAIRE SYSTEMS
FIRE
SYSTEM
NO
TAG TYPE SIZE SUPPLIED BY
1
2
0 - 0 - TANK FIRE SUPPRESSION POST-DISCHARGE PROCEDURE UTILITY CABINET LABEL SHEET.
0 - 0 - TANK FIRE SUPPRESSION MAINTENANCE GUIDE UTILITY CABINET LABEL SHEET.
0 - 0 - 12-F28021-32144-OT-360 DUCT FIRE THERMOSTAT WITH 12 FOOT WIRE LEADS. NO,
CLOSE ON TEMP RISE AT 360°F. (A0034310).
0 - 0 - 4429K153 1/2" MALE NPT TO 1/2" FEMALE NPT ELBOW, BRASS.
0 - 0 - 4429K422 1/2" X 1/4" BRASS REDUCING BUSHING.
0 - 0 - 79525 1/2" 90 PRO-PRESS ELBOW WITH 1/2” NPT FEMALE CONNECTION, VIEGA.
0 - 0 - 79580 1/2" X 1/2" PRO-PRESS TEE X 1/2” NPT FEMALE CONNECTION, VIEGA.
0 - 0 - 87-120045-001 HOSE, SECONDARY ACTUATOR HOSE, 7.5" BRAIDED STAINLESS STEEL,
TANK FIRE SUPPRESSION.
0 - 0 - 87-300001-001 TANK - PRESSURIZED TANK USED FOR TANK FIRE SUPPRESSION.
0 - 0 - 87-300030-001 PRIMARY ACTUATOR KIT (PAK) - ACTUATOR AND RELEASE SOLENOID
ASSEMBLY, ONE NEEDED PER FIRE SYSTEM, SUPERVISED, TANK FIRE SUPPRESSION.
0 - 0 - 87-300152-001 HARDWARE, SVA BOLTS, TANK FIRE SUPPRESSION.
0 - 0 - 98694A115 HARDWARE, DATANKLOCK LOCKING BRACKET SQUARE NUTS 5/16" ZINC, TANK
FIRE SUPPRESSION.
0 - 0 - A0034332 JUNCTION BOX FOR MANUAL PULL STATION. 1.5" DEEP BACK BOX, RED COLOR.
0 - 0 - A31484 1/4" NPT SCHRADER VALVE AND CAP, JB INDUSTRIES. 1/4" FLARE X 1/4"
MPT HALF UNION. USED ON TANK SERVICE PORT.
0 - 0 - DATANKLOCK DISCHARGE ADAPTER TANK LOCKING PLATE FOR FIRE SYSTEM TANK INSTALLATION
IN UTILITY CABINETS, TANK FIRE SUPPRESSION.
0 - 0 - SLPCON-03FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO
CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 2' GAP. KIT
CONTAINS 5 FEET OF BLACK MG WIRE, 5 FEET OF TAN MG WIRE, 3 FEET OF FLEXIBLE CONDUIT,
AND TWO 7/8" CONNECTORS.
0 - 0 - SLPCON-10FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO
CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 9' GAP OR BACK
TO BACK HOODS. KIT CONTAINS 12 FEET OF BLACK MG WIRE, 12 FEET OF TAN MG WIRE, 10
FEET OF FLEXIBLE CONDUIT, AND TWO 7/8" CONNECTORS.
0 - 0 - SLPCON-30FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO
CONNECT THE SUPERVISED LOOP BETWEEN HOODS WITH UPTO 29' GAP. KIT CONTAINS 32 FEET
OF BLACK MG WIRE, 32 FEET OF TAN MG WIRE, 30 FEET OF FLEXIBLE CONDUIT, AND TWO 7/8"
CONNECTORS.
0 - 0 - TANK STRAP TANK STRAP - USED FOR TANK FIRE SUPPRESSION.
0 - 0 - TFS-UCTANKBRACKET TANK BRACKET FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY
CABINETS, TANK FIRE SUPPRESSION.
0 - 0 - WK-283952-000 DISCHARGE ADAPTER, TANK FIRE SUPPRESSION.
34 - 34 - A0034331 24VDC SINGLE ACTION MANUAL ACTUATION DEVICE (PUSH/PULL STATION)
WITH PROTECTIVE COVER, ONE (1) NORMALLY OPEN CONTACT. RED COLOR.
0 - 0 - 87-120042-001 SECONDARY ACTUATOR VALVE (SVA) - SINGLE ACTUATOR, REQUIRES
PRIMARY RELEASE ACTUATOR, TANK FIRE SUPPRESSION.
0 - 0 - 87-120045-001 HOSE, SECONDARY ACTUATOR HOSE, 7.5" BRAIDED STAINLESS STEEL,
TANK FIRE SUPPRESSION.
0 - 0 - 87-300001-001 TANK - PRESSURIZED TANK USED FOR TANK FIRE SUPPRESSION.
0 - 0 - 87-300030-001 PRIMARY ACTUATOR KIT (PAK) - ACTUATOR AND RELEASE SOLENOID
ASSEMBLY, ONE NEEDED PER FIRE SYSTEM, SUPERVISED, TANK FIRE SUPPRESSION.
0 - 0 - 87-300033-001 DIN CONNECTOR, CANFIELD PART #5J560-201-EU0A, TANK FIRE SUPPRESSION,
SUBMINATURE SOLENOID CONNECTION (CED VENDOR 30377).
0 - 0 - 87-300152-001 HARDWARE, SVA BOLTS, TANK FIRE SUPPRESSION.
0 - 0 - TANK STRAP TANK STRAP - USED FOR TANK FIRE SUPPRESSION.
0 - 0 - TFS-UCTANKBRACKET TANK BRACKET FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY
CABINETS, TANK FIRE SUPPRESSION.
0 - 0 - WK-283952-000 DISCHARGE ADAPTER, TANK FIRE SUPPRESSION.
1
1
3
4
3
3
4
2
4
2
16
8
2
3
4
1
1
1
12
4
4
2
2
2
3
1
1
6
9
3
3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
FIRE
SYSTEM
NO
TAG KEY NUMBER - PART DESCRIPTION QTY BY
FACTORY
QTY BY
DIST
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.6
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
FACTORY PIPING EXTENDS A MAXIMUM
OF 6" ABOVE THE TOP OF THE HOOD.
12"
Ø14"
12"
Ø14"
HOOD FRONT
HOOD BACK
HOOD # 1 (KH-1) JOB # 6950327 FS # 1
MODEL: ND-2-PSP-F SIZE: 54"x24" LENGTH: 14' 6"
TA
N
K
O
V
E
R
L
A
P
P
I
N
G
P
R
O
T
E
C
T
I
O
N
-
3
0
HI
G
H
P
R
O
X
I
M
I
T
Y
16
2
.
0
0
"
L
X
2
4
.
0
0
"
D
DUCT
S
360
OL-F
DUCT
S
360
OL-F
OL-F OL-F
24.00"
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
NOZZLE HEIGHT
35-50" FROM
COOKING SURFACE.
(45.25")
18.00"27.60"27.60"27.60"27.60"27.60"18.00"
SLPCON-03FT
KIT
SLPCON-30FT
KIT
- SYSTEM REQUIRES A MINIMUM OF 7 FT OF
EQUIVALENT PIPE LENGTH BETWEEN TANK AND
NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES.
EACH 90 DEGREE ELBOW ADDS 1.3 FT OFEQUIVALENT LENGTH. SEE MANUAL FOR DETAILS
- SYSTEM REQUIRES A MINIMUM OF 7 FT OF
EQUIVALENT PIPE LENGTH BETWEEN TANK AND
NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES.
EACH 90 DEGREE ELBOW ADDS 1.3 FT OF
EQUIVALENT LENGTH. SEE MANUAL FOR DETAILS
7
1 2 5
- SYSTEM REQUIRES A MINIMUM OF 7 FT OF
EQUIVALENT PIPE LENGTH BETWEEN TANK AND
NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES.
EACH 90 DEGREE ELBOW ADDS 1.3 FT OFEQUIVALENT LENGTH. SEE MANUAL FOR DETAILS
- SYSTEM REQUIRES A MINIMUM OF 7 FT OF
EQUIVALENT PIPE LENGTH BETWEEN TANK AND
NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES.
EACH 90 DEGREE ELBOW ADDS 1.3 FT OF
EQUIVALENT LENGTH. SEE MANUAL FOR DETAILS
1
631
1 3 6
2 5
FACTORY PIPING EXTENDS A MAXIMUM
OF 6" ABOVE THE TOP OF THE HOOD.
12"
Ø10"
HOOD FRONT
HOOD BACK
HOOD # 2 (KH-2) JOB # 6950327 FS # 1
MODEL: ND-2-PSP-F SIZE: 54"x24" LENGTH: 5' 6"
TA
N
K
O
V
E
R
L
A
P
P
I
N
G
P
R
O
T
E
C
T
I
O
N
-
3
6
HI
G
H
P
R
O
X
I
M
I
T
Y
54
.
0
0
"
L
X
2
4
.
0
0
"
D
DUCT
S
360
OL-F
OL-F
24.00"
21.50"
OL-F
21.50"
OL-F
NOZZLE HEIGHT
35-50" FROM
COOKING SURFACE.
(45.25")
18.00"30.00"18.00"
SLPCON-10FT
KIT
PL
E
N
U
M
ALTERNATE FIELD-CONNECTION POINTPL
E
N
U
M
PL
E
N
U
M
NOTES
- FIELD PIPE DROPS AS SHOWN
PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS.
- FIELD INSTALLED DROP: FACTORY WILL PROVIDE QTY 2 60IN LONG PIECES OF CHROME
PLATED PIPING SHIPPED LOOSE TO BE FIELD-INSTALLED.
- SHIP LOOSE DROP: FACTORY WILL PROVIDE THE EXACT CHROME PIPE LENGTH NEEDED
SHIPPED LOOSE TO BE FIELD-INSTALLED.
- RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING,
SALAMANDERS, ETC.
- OVERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN OBSTRUCTION.
- IF APPLICABLE, EXTENDED PRE-PIPED DROPS ARE SHIPPED LOOSE.
- FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD.
- APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE
SIZE, NOT THE OVERALL APPLIANCE SIZE.
- THIS PRE-ENGINEERED FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS.
- OL-F NOZZLE PART NUMBER REPLACES 3070-3/8H-10-SS
JOB #: 6950327.
JOB NAME: RAISING CANE'S 1032.
SYSTEM SIZE: TANK-SP-1 WITH REMOTE TANK-SP-3 DESIGN FP: 62. MAXIMUM FP: 80.
HOOD # 1 14' 6.00" LONG x 54" WIDE x 24" HIGH.
RISER # 1 SIZE: 14" DIA.
RISER # 2 SIZE: 14" DIA.
HOOD # 1 METAL BLOW-OFF CAPS INCLUDED.
HOOD # 2 5' 6.00" LONG x 54" WIDE x 24" HIGH.
RISER # 1 SIZE: 10" DIA.
HOOD # 2 METAL BLOW-OFF CAPS INCLUDED.
- HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITIONAL DOWNSTREAM
FIRESTAT IN THE EVENT THAT THE DUCTWORK CONTAINS ANY HORIZONTAL RUNS OVER 25
FT IN LENGTH.
- MEDIUM TO LIGHT-DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE ANY ADDITIONAL
DOWNSTREAM DETECTION.
AGENT DISTRIBUTION PIPING LIMITATIONS
PIPE SECTION MAX PIPE LENGTH (FT)
MAX SUPPLY LINE TO FIRST OVERLAPPING NOZZLE 42
OVERLAPPING NOZZLE APPLIANCE BRANCH 10
DEDICATED NOZZLE APPLIANCE BRANCH 10
PRESSURE SUPERVISION SWITCH.
PRIMARY ACTUATOR RELEASE.
4 GALLON TANK.
7
6
5
4
2
1
PRIMARY HOSE ASSEMBLY.
SECONDARY ACTUATOR RELEASE.3
SECONDARY HOSE ASSEMBLY.
REMOTE MANUAL ACTUATION DEVICE.
1" LAYER OF INSULATION FACTORY
INSTALLED IN 3" INTERNAL STANDOFF.
MEETS 0 INCH REQUIREMENTS FOR
CLEARANCE TO COMBUSTIBLE SURFACES.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§EXHAUST RISER.
HANGING ANGLE.
RECESSED ROUND LED FIXTURE AND LED LIGHT,
3500 K WARM OUTPUT.
23.5% OPEN STAINLESS
STEEL PERFORATED PANEL.
ATTACHING PLATES.
SUPPLY RISER WITH
VOLUME DAMPER.
6"
2 3/4"
14"
LED.
18"
1.00" WIDE INSULATED
BACKSPLASH 122.00" HIGH
X 234.00" LONG.
FIELD WRAPPER 8.00" HIGH
(SEE HOOD OPTIONS TABLE).
1" LAYER OF INSULATION FACTORY INSTALLED
ON TOP OF HOOD. MEETS 0 INCH
REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE
SURFACES.
23"
23"
LEFT AND RIGHT QUARTER END PANELS.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"1"
55"
*6"
*6" CLEARANCE ABOVE HOOD
REQUIRED FOR FIRE SYSTEM PIPING.
*6" CLEARANCE ABOVE HOOD
REQUIRED FOR FIRE SYSTEM PIPING.
*24"
*24" CLEARANCE ABOVE HOOD
RECOMMENDED FOR SERVICEABILITY.
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" CAPTRATE SOLO
FILTER WITH HOOK.
21 1/2"
1" LAYER OF INSULATION FACTORY
INSTALLED IN 3" INTERNAL STANDOFF.
MEETS 0 INCH REQUIREMENTS FOR
CLEARANCE TO COMBUSTIBLE SURFACES.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§EXHAUST RISER.
HANGING ANGLE.
RECESSED ROUND LED FIXTURE AND LED LIGHT,
3500 K WARM OUTPUT.
23.5% OPEN STAINLESS
STEEL PERFORATED PANEL.
ATTACHING PLATES.
SUPPLY RISER WITH
VOLUME DAMPER.
6"
2 3/4"
14"
LED.
18"
1.00" WIDE INSULATED
BACKSPLASH 122.00" HIGH
X 66.00" LONG.
FIELD WRAPPER 8.00" HIGH
(SEE HOOD OPTIONS TABLE).
1" LAYER OF INSULATION FACTORY INSTALLED
ON TOP OF HOOD. MEETS 0 INCH
REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE
SURFACES.
23"
23"
LEFT AND RIGHT QUARTER END PANELS.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"1"
55"
*6"
*6" CLEARANCE ABOVE HOOD
REQUIRED FOR FIRE SYSTEM PIPING.
*6" CLEARANCE ABOVE HOOD
REQUIRED FOR FIRE SYSTEM PIPING.
*24"
*24" CLEARANCE ABOVE HOOD
RECOMMENDED FOR SERVICEABILITY.
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" CAPTRATE SOLO
FILTER WITH HOOK.
21 1/2"
TANK FIRE
SUPPRESSION
PUSH
4-5/8"
3-3/16"
5-3/8"
7-3/8"
INCLUDES: FIELD INSTALLATION AND HOOKUP DURING NORMAL BUSINESS HOURS BY
CERTIFIED INSTALLERS ONLY IN THE LOCATION NOTED ABOVE, TWO SITE VISITS ONLY (ONE
VISIT TO SET PULL STATION & SYSTEM HOOKUP AND ONE VISIT FOR ONE TEST; ADDITIONAL
VISITS WILL RESULT IN ADDITIONAL CHARGES), ONE MECHANICAL OR ELECTRICAL GAS
VALVE PER SYSTEM AT A MAXIMUM SIZE OF 2", PERMIT, AND SYSTEM TEST.
EXCLUDES: UNION LABOR & PREVAILING WAGE (LABOR & WAGES WILL BE ADDED IF
APPLICABLE), GAS VALVE INSTALLATION, ELECTRICAL HOOKUP AND CONNECTIONS, HANGING
OF FIRE CABINET, SHUNT TRIP, HANDHELD EXTINGUISHER(S), ON-SITE RE-PIPING DUE TO
EQUIPMENT LAYOUT CHANGES.SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.7
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
26"
34"Ø 42"
18"
MINIMUM
CLEARANCE
TO
COMBUSTIBLES.
18"
MINIMUM
CLEARANCE
TO
COMBUSTIBLES.
18"
MINIMUM
CLEARANCE
TO
COMBUSTIBLES.
18"
MINIMUM
CLEARANCE
TO
COMBUSTIBLES.
46 1/8"
5 1/4"
28"
FIRE SENSOR.
NOZZLE PART#
.
1/8"
GASKET.
28"
1/8"
GASKET.
28"
1/8"
GASKET.
35"
FIRE SENSOR.
25 1/4"
56 3/8"
30 1/2"
42 3/8"
49 1/4"
2" DRAIN
EXTENSION.56 3/16"2"
28 3/16"
119 5/16"
86 5/8"
205 7/8"
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.8
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
1 PCU-1 1 USBI24DD-RM CAPTIVEAIRE 4224 2.100 1321 ODP,PREMIUM 7.500 5.5620 3 208 22.3 1400 FPM 2197 35.8
FAN
UNIT
NO
TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR
ENCL HP BHP PHASE VOLT FLA DISCHARGE
VELOCITY
WEIGHT
(LBS)SONES
2 MAU-1 A2-20D-MPU 1
2
2.5
5
208-230
208-230
3 PHASE
3 PHASE
60 HZ
60 HZ
11.2 AMPS
21.4 AMPS
9.07 AMPS
17.4 AMPS
20 AMPS
30 AMPS
14 AWG
10 AWG
14
14
FAN
UNIT
NO
TAG FAN UNIT MODEL #CONDENSER
NO TONNAGE VOLTAGE PHASE FREQUENCY MCA RLA MAX FUSE
SIZE
MIN WIRE
SIZE SEER
2 MAU-1 1 A2-20D-MPU 20MF-2-MOD A2 2700 3314 0.500 1251 ODP,PREMIUM 2.000 1.1050 3 208 6.1 7.7A 15A 1348 13.7
FAN
UNIT
NO
TAG QTY FAN UNIT MODEL #BLOWER HOUSING MIN
CFM
DESIGN
CFM ESP RPM MOTOR
ENCL HP BHP PHASE VOLT FLA MCA MOCP WEIGHT
(LBS)SONES
2 MAU-1 DX 3314 90.0°F 69.0°F 74.2°F 63.8°F ------------56.8 MBH 54.8 MBH 2.0 MBH ---------------------------
FAN
UNIT
NO
TAG COIL
TYPE
DESIGN
CFM
COOLING
ENTERING DB
TEMP
ENTERING WB
TEMP
LEAVING DB
TEMP
LEAVING WB
TEMP
ENTERING
FLUID TEMP
LEAVING FLUID
TEMP
FLUID FLOW
RATE
PERCENT
GLYCOL
TOTAL
CAPACITY
SENSIBLE
CAPACITY
LATENT
CAPACITY
HEATING
ENTERING DB
TEMP
LEAVING DB
TEMP
ENTERING
FLUID TEMP
LEAVING FLUID
TEMP
FLUID FLOW
RATE
PERCENT
GLYCOL
STEAM
PRESSURE
TOTAL
CAPACITY
SENSIBLE
CAPACITY
1
2
PCU-1
MAU-1
YES
FAN
UNIT
NO
TAG
EXHAUST
GREASE
CUP
GRAVITY
DAMPER
WALL
MOUNT
SUPPLY
SIDE
DISCHARGE
GRAVITY
DAMPER
MOTORIZED
DAMPER
WALL
MOUNT
1
2
3
4
# 2 MAU-1
PCU-1
20 LBS
76 LBS
76 LBS
125 LBS
RAIL
CURB
CURB
RAIL
RAIL
RAIL
RAIL
RAIL
6.000"W X 21.000"L X 20.000"H.
31.000"W X 121.000"L X 20.000"H INSULATED.
31.000"W X 121.000"L X 20.000"H INSULATED.
6.000"W X 45.250"L X 20.000"H.
6.000"W X 45.250"L X 20.000"H.
6.000"W X 45.250"L X 20.000"H.
6.000"W X 45.250"L X 20.000"H.
6.000"W X 45.250"L X 20.000"H.
NO ON
FAN TAG WEIGHT ITEM SIZE
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.9
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
FAN
UNIT
NO
TAG QTY DESCRIPTION
1 PCU-1
1 UTILITY SET GREASE CUP
1 BI24 - 24" DISCHARGE EXTENSION
1 BI - DISCHARGE ORIENTATION VERTICAL UPPER LEFT - CW INLET SIDE
1 BI24 - INLET CONNECTION STANDARD 24" FLANGED GREASE DUCT
1
POLLUTION CONTROL UNIT WITH PREFILTER, DUAL HIGH EFFICIENCY, AND ODOR CONTROL
FILTERS WITH INSTALLED ELECTRIC DETECTION SYSTEM. PRESET TO ACTIVATE AT 360°
F. SIZE 4
1 PCU-SIZE 4 USBI-24 DD
1 BLUE RUBBER VIBRATION ISOLATORS FOR BI UTILITY SETS (SET OF 8)
1 2 YEAR PARTS WARRANTY
2 MAU-1
1 SIZE 2 UNTEMPERED COMMERCIAL DOWN DISCHARGE FOR DIRECT DRIVE AHUS
1 INSULATED BLOWER SECTION SIZE 1-2 COMMERCIAL
1 MIXING BOX SHELL FOR SIZE 2 MOD PACKAGE UNIT CONDENSER SUPPORT
1
7.5 TON 2 CIRCUIT (2.5/5) MODULAR PACKAGED COOLING OPTION FOR SIZE 2 MUA (2,700
TO 4,500 CFM), 208V/230V, 3 PHASE. COOLING THERMOSTAT OR PROGRAMMABLE STAT REQUIRED
FOR PROPER OPERATION
1 MOD PACKAGE UNIT AC CONTROLS FOR UNTEMPERED FANS
1 SHIP CONDENSERS LOOSE - TWO CONDENSERS, THREE PHASE - CONDENSER DISCONNECTS
SHIPPED LOOSE. ALL PIPING AND WIRING BETWEEN INDOOR AND OUTDOOR UNITS BY OTHERS
1 SEPARATE 120V WIRING PACKAGE (REQUIRED AND USED ONLY FOR DCV OR PREWIRE WITH
VFD) - THREE PHASE ONLY
1 2 YEAR PARTS WARRANTY
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.10
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
13 1/4"
25 3/4"
28 3/16"
43 15/16"
41 3/4"
26"
34"Ø42"
18"
MINIMUM
CLEARANCE
TO
COMBUSTIBLES.
18"
MINIMUM
CLEARANCE
TO
COMBUSTIBLES.
18"
MINIMUM
CLEARANCE
TO
COMBUSTIBLES.
18"
MINIMUM
CLEARANCE
TO
COMBUSTIBLES.
46 1/8"
5 1/4"
28"
1/8"
GASKET.
28"
1/8"
GASKET.
28"
1/8"
GASKET.
35"
SERVICE
DISCONNECT
SWITCH.
UL 1978 BOLTED
DOOR CONSTRUCTION.
25 1/4"
56 3/8"
30 1/2"
42 3/8"
49 1/4"
2" DRAIN
EXTENSION.56 3/16"2"
28 3/16"
119 5/16"
86 5/8"
205 7/8"
12"9"9"9"
18"
MINIMUM
CLEARANCE
TO
COMBUSTIBLES.
18"
MINIMUM
CLEARANCE
TO
COMBUSTIBLES.
44"
42 5/8"
46 1/2"
EXTENSION.
45 1/4"45 1/4"
6"
61 3/16"
92 5/8"
150 7/8"
202"
20.000" HIGH
EQUIPMENT
RAIL.
14 3/4"
L ETSDI
R
PCU OPTIONS:
- PCU ADVANCED FILTER MONITORING SYSTEM- SIZE 4.
- INLET 41.719" BY 43.963" RECTANGULAR TO 34" ROUND TRANSITION FOR SIZE 4. 26" LONG.
- UL-1978/UL-8782 CONSTRUCTION FOR PCUS-BOLTED DOOR DESIGN- SIZE 4.
- CLIMATE CONTROLLED UTILITY CABINET FOR FIRE SYSTEM INSTALLATION. FOR USE WITH FIRE SYSTEMS.
FAN OPTIONS:
- UTILITY SET GREASE CUP
- BI24 - 24" DISCHARGE EXTENSION.
- BI - DISCHARGE ORIENTATION VERTICAL UPPER
LEFT - CW INLET SIDE.
- BI24 - INLET CONNECTION STANDARD 24"
FLANGED GREASE DUCT.
- POLLUTION CONTROL UNIT WITH PREFILTER,
DUAL HIGH EFFICIENCY, AND ODOR CONTROL
FILTERS WITH INSTALLED ELECTRIC DETECTION
SYSTEM. PRESET TO ACTIVATE AT 360° F. SIZE 4
- PCU-SIZE 4 USBI-24 DD
- BLUE RUBBER VIBRATION ISOLATORS FOR BI
UTILITY SETS (SET OF 8)
- 2 YEAR PARTS WARRANTY
1
2
3
4
CAPTRATE SOLO
HIGH EFFICIENCY
HIGH EFFICIENCY
OC 100% CARBON
MERV 8
MERV 15
MERV 15
N/A
10
10
10
10
20X25X2
20X25X4
20X25X4
20X25X4
0.345
0.228
0.228
0.704
1.505
PCU FILTER SPECIFICATIONS
DESIGN CFM - 4224
MODULE FILTER TYPE FILTER EFFICIENCY QTY SIZE SP(CLEAN)
(in WC)
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.11
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
121"
FLEX
CONDUIT
FOR FIELD
WIRING.
BLOWER DISCHARGE.
16"
10"
18 3/4"
8 5/8"
LIFTING LUG.
AIRFLOW.
BLOWER/MOTOR
ACCESS DOOR
24" SERVICE
CLEARANCE REQ.
SERVICE DISCONNECT
SWITCH.
AIRFLOW.
COOLING
COIL
MODULE.
1" MPT CONNECTION FOR
SS PITCHED DRAIN PAN.
COIL
ACCESS
DOOR.AIRFLOW.
AIRFLOW.
49 3/8"
16 1/4"
31"
20" EQUIPMENT CURB.
40 1/8"
36 3/4"
42 1/8"
47 3/4"
49 3/8"
82 1/4"
42 1/8"
178"
MIN. 20"
MINIMUM
STRAIGHT
DUCT
PER AMCA*
FAN #2 A2-20D-MPU - SUPPLY FAN (MAU-1)
1. SUPPLY UNIT WITH 20" MIXED FLOW DIRECT DRIVE FAN IN SIZE #2 HOUSING.
2. INTAKE HOOD WITH EZ FILTERS.
3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT.
4. DOWN DISCHARGE CONSTRUCTION FOR SIZE 2 UNTEMPERED DIRECT DRIVE AHUS.
5. INSULATED BLOWER HOUSING SIZES 1-2 COMMERCIAL MODULAR.
6. SUPPORT SHELL FOR SIZE 2 MODULAR PACKAGE UNIT. INCLUDES CONTROL VESTIBULE. INCLUDES CONDENSER SUPPORTS. DOES NOT INCLUDE
RETURN AIR OR INLET AIR DAMPER.
7. 7.5 TON, DUAL CIRCUIT (2.5/5) MODULAR PACKAGED COOLING OPTION FOR SIZE 2 MODULAR PACKAGED UNIT. INCLUDES CONDENSER, DX COIL,
FILTER/DRYER KIT, THERMAL EXPANSION VALVE. (2,700 TO 4,500 CFM) WHEN ORDERED WITH OPPOSITE AIRFLOW CONDENSERS ACCESS AND COIL PIPING
WILL REMAIN IN STANDARD POSITION. DRAIN AND SLEDS WILL MOVE TO THE OPPOSITE SIDE. ANY OTHER CHANGE WILL REQUIRE CLI. CONDENSERS
REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. COIL = 3EZ1101C.
8. CONTROL PACKAGE FOR MOD PACKAGE UNIT COOLING ONLY UNIT. INCLUDES AIRFLOW PROVING SWITCH, RTULINK-ACHP BOARD AND TERMINAL BLOCKS.
9. SHIP CONDENSERS LOOSE. THE REFRIGERATION LINES WILL NEED TO BE STUBBED OUT 12 INCHES. THE SUCTION LINES NEEDS TO BE INSULATED INSIDE
THE COIL MODULE. ROTARY DISCONNECT SHOULD NOT BE INSTALLED ON THE POST, BLANK POST SHOULD BE USED IN PLACE. ALL PIPING AND WIRING
BETWEEN INDOOR AND OUTDOOR UNITS BY OTHERS.
10. SEPARATE 120VAC WIRING PACKAGE FOR MAKE-UP AIR UNITS. OPTION MUST BE SELECTED WHEN MOUNTING VFD IN PREWIRE PANEL OR WITH DCV
PACKAGE. PROVIDES SEPARATE 120VAC INPUT TO SUPPLY FAN. THIS 120V SIGNAL MUST BE RUN BY ELECTRICIAN FROM DCV TO MUA SWITCH.
11. HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER/MPU SECTION).
12. 2 YEAR PARTS WARRANTY.
*NOTE: SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF
UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST BE RADIUS THROAT, RADIUS BACK WITH
TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE
DUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT
TO SUPPORT DUCT IN ANY WAY. FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT.
SUGGESTED STRAIGHT DUCT SIZE IS 20" x 20".
**NOTE: CONDENSERS SHIPPED LOOSE FOR REMOTE MOUNTING. ALL WIRING AND PIPING BETWEEN INDOOR AND OUTDOOR UNIT TO BE COMPLETED BY
OTHERS.
L ETSDI
R
ROOF OPENING 2" SMALLER THAN CURB DIMENSION.
6"
6"
3" FLANGE.
20 GAUGE
CONSTRUCTION.
STEEL
20"
31"121"
OPTIONS:
- FULL BOTTOM CORNERS.
CURB.
6"
24"
SERVICE.
24"
SERVICE.
24"
SERVICE.
24"
SERVICE.
18"18"
48" CLEARANCE REQUIRED ABOVE CONDENSERS.
(NOTE: **CONDENSERS SHOWN HERE ARE NOT DRAWN AT SCALE).
6"12"
12"
12"
12"
18"
12" MIN.
5 13/16"
CLEAN OUT.
TYPICAL DRAIN TRAP INSTALL
NO UNIONS.
RECOMMENDED COOLING COIL
DRAIN TRAP CONFIGURATION.
NOTES:
1) 1" DIAMETER PVC PIPE ONLY.
2) USE ONLY LOW PROFILE COUPLINGS.
3) ADD CLEAN OUT AS SHOWN.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
21"21"
22 15
16"
SUCTION LINE
LIQUID LINE
6"
20"
22 15
16"
6"
M3.12
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
SW-01
BK
BK
MT-01
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
GR
BK
GR
Label Description Location
MT-01 Supply motor [2]
SW-01 Main disconnect switch [2]
Component Identification
23
BK
BK
BK
Installed Options
DENOTES INTERNAL WIRING
DENOTES FIELD WIRING
NOTES
7 8RD(DCV SF1)WH (DCV N1)
DCV/VFD Wiring
(MAY NOT BE NEEDED DEPENDING ON OPTIONS)
IF DCV IS NOT PRESENT, RD AND WH WIRES FROM
SEPARATE 120VAC SOURCE
RTUlink-ACHPTS-06 [16]
DDP-106-313 AFSPS-01 [17]
SW-02
CONDENSER 1
CONDENSER 2
GR
3 PHASE
208/230
BL
GR
BL
9
5
COIL
13 23
CONT2
11 21
COMP1
10
6 CONT1
COIL
13
11
23
21 T3
T2
T1
BL 21 BL
BL
BL
SW-02
RD
RD
RD
11
7
3
12
8
4
208/230
3 PHASE
T3
COMP2
T2
T1
RD
RD
RD
BL
Condenser Wiring
[18]40 Amp Rotary DisconnectSW-02 [15]
Cooling Transformer(40va)TR-05 [4]
BK WH
1 TR-05115
BL 24 YW
N
RCR1
BK RD WH WH
YW
RC
YW
RC
OR
Y2
GY
Y1
MOCP = 10 AMPS FOR CONTROL WIRING
DROP FOR DISCONNECT CONNECTION
!ATTENTION ELECTRICIAN!
CONNECT POWER TO THE DROP
1 2
5 6
3 4
BL
[16-17]Overflow Switch SW-06
TS-06
+
COOL STAGE ON TIMER = 2 MIN.
COOL STAGE OFF TIMER = 2 MIN.
COOL HYSTERESIS = 1 MIN.
C
SN-01
BK
GY
OR
+C
SN-02
BK
[20]Outside Air SensorSN-01
[20]Discharge Air SensorSN-02
STANDARD PARAMETERS
Y1
Y2
Outside
Temp
Discharge
Temp
RD RD
RC
PS-01
R1
BK
NO
C
NC
C
BL R
SW-06
FL
R1
Alarm 1
AirflowBL
BL
YW
RD
BK
CONDENSER(S) TO
BE FIELD WIRED
CONTROL MODE = COOL
STAGE BASED ON = OUTSIDE
ACTIVATE BASED ON = OUTSIDE
MODE CHANGE TIME = 5 MIN.
SINGLE STAGE COOLING
STAGE 1 COOLING SETPOINT = 85°F
TWO STAGES COOLING
STAGE 1 COOLING SETPOINT = 85°F
STAGE 2 COOLING SETPOINT = 95°F
THREE STAGES COOLING
STAGE 1 COOLING SETPOINT = 85°F
STAGE 2 COOLING SETPOINT = 90°F
STAGE 3 COOLING SETPOINT = 95°F
IS FACTORY SUPPLIED
Y1
Y2
WIRE COLOR
YW - YELLOW
GY - GRAY
PR - PURPLE
GR - GREENBL-BLUE
BR - BROWN
OR - ORANGE
BK-BLACK
WH - WHITE
PK - PINK
RD - RED
SUPPLY 2.0HP-208V-3P-6.1FLA
MOTOR INFO
ELECTRICAL INFORMATION
MOTOR CIRCUIT MCA: 7.7A
CONTROL CIRCUIT MCA: 1.0A
MOTOR CIRCUIT MOP: 15A
CONTROL CIRCUIT MOP: 15A
COND1 MCA = 21.4A COND1 MOP = 30A
COND2 MCA = 11.2A COND2 MOP = 20A
DRAWING NUMBER
JOB
MODELSHIP DATEA6950327-2
6950327 - Raising Cane's 1032
7/2/2025
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Label Description Location
MT-01 Fan Motor [3]
SW-01 Main disconnect switch [3]
Component Identification
23
Installed Options
RD - RED
BL - BLUE
WH - WHITE
OR - ORANGE
BR - BROWN
BK - BLACK
PK - PINK
PR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
DENOTES FIELD WIRING
DENOTES INTERNAL WIRING
NOTES
SW-01
BK
BK
MT-01
GR
BK
GR
BK
BK
BK
5 6
3 4
1 2
GR
EXHAUST 7.5HP-208V-3P-22.3FLA
VFD PART: ESV552N02TXB571
MOTOR INFO
ELECTRICAL INFORMATION
MOTOR/CTRL MCA: 27.9A
MOTOR/CTRL MOP: 50A
DRAWING NUMBER
JOB
MODELSHIP DATEEXH6950327-1
6950327 - Raising Cane's 1032
7/2/2025
24
25
23
22
21
20
XX TERMINAL IN PANEL
INTERNAL WIRING
FIELD WIRING
NOTES
19
18
17
16
15
14
13
12
7
9
11
10
8
6
5
4
3
DRAWING NUMBER
2
1
JOB NAME
JOB NUMBER
DATE
COMPONENT IDENTIFICATION
DescriptionLabel Location
PCU#2-6950327-1
Raising Cane's 1032
6950327
7/2/2025
PCB-01
J1
-
4
(
I
O
2
)
J1
-
3
(
I
O
3
)
J1
-
2
(
I
O
4
)
J1
-
1
(
N
)
J1
-
5
(
I
O
1
)
J1
-
6
(
P
2
)
J1
-
7
(
P
3
)
J1
-
8
(
H
1
)
N1 H1
P2
J4 J3
FOR STANDARD CONTROL PANEL, CONNECT H1, N1 P2 TO LIKE TERMINALS IN ELECTRICAL CONTROL PACKAGEFOR SC OR DCV, CONNECT CAT-5 CABLE FROM RJ-45 INSIDE PCU TO J3 OF ECPM03 PCB.
PR - PURPLE
WH - WHITE
OR - ORANGE
BR - BROWN
BK - BLACK
PK - PINK
RD - RED
BL - BLUE
GY - GRAY
OR/BL - ORANGE/BLUE
(STRIPE)
BL/RD - BLUE/RED
(STRIPE)RD/GN - RED/GREEN
(STRIPE)
GR - GREEN
YW - YELLOW
WIRE COLOR
TO ECPM03 BOARD
FAULT OUTPUT
NEUTRAL 120 VAC INCOMING POWER
24 VAC
RELAY
RA-x
CB-01 DSW-01
FH1
PCU-AFM
WH BK
BK
BK
MO
D
B
U
S
C
O
M
M
U
N
I
C
A
T
I
O
N
CB-01 Circuit Breaker [6]
DSW-01 Disconnect Switch [6]
PCB-01 PCUAFM - A0018883 [2]
Drawing Shown De-energizedTamper switches made C to NO when door is closed (Typical)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
DRAWING NUMBER JOB NUMBER
JOB NAME
MODEL
DATE
Installed Options
DENOTES INTERNAL WIRING
DENOTES FIELD WIRING
** TERMINAL 11 PROVIDES COOLING
CONNECTION
WH - WHITE
RD - RED
OR - ORANGE
BR - BROWN
BL - BLUE
BK - BLACK
PK - PINK
PR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
NOTES
PCU#2-6950327-2
Raising Cane's 1032
6950327
7/2/2025
WH
SET THERMOSTAT TS-01 (HEAT) TO 40°F.
SET THERMOSTAT TS-02 (COOL) TO 90°F.
120VAC FROM FIRE SYSTEM ECP, MOCP=15 AMPS
N1
H1
WH
BK
TS-02
BL
WH
R
W
B
MT-02
MT-01
CB-01 TS-01
BK R RDB
YW
W
HS-02
HS-01
T6031A1136 THERMOSTAT
T6031A1136 THERMOSTAT
S201U-K15 CIRCUIT BREAKER
1976K42 EXHAUST FAN
1976K42 EXHAUST FAN
200WSTPHTR HEATER
Component Identification
200WSTPHTR HEATER
Description
TS-02
TS-01
CB-01
MT-02
MT-01
HS-02
HS-01
Label Location
[3]
[2]
[1]
[1]
[2]
[2]
[1]
CB-01 INSIDE ECP BOX
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.13
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
1
2
SC-311110MA
PCU-CAS-TANK
UTILITY CABINET LEFT
PCU CONDITIONED TOP MOUNT UC
UTILITY CABINET LEFT
HOOD # 1
NO SWITCHES
1 LIGHT
1 FAN
2 OTHER
SMART CONTROLS THERMOSTATIC CONTROL W/
RELAY ON/OFF WITH SUPPLY
PCU-1
MAU-1
EXHAUST
SUPPLY
3
3
7.500
2.000
208
208
22.3
6.1
NO TAG PACKAGE #LOCATION
SWITCHES
LOCATION QUANTITY
OPTION
FANS CONTROLLED
FAN TAG TYPE ɸ HP VOLT FLA
Field Connection Antennas
Wired OR Paddle
Field Connection to Router
OR Ethernet switch
Connection for Modbus
Factory wired OR Field Wired
Terminal Blocks for wired connection
Cellular Module
Compute module
DESCRIPTION OF OPERATION:
6950327
Raising Cane's 1032
SC-311110MA
7/2/2025
INSTALL
ECP #1-1
3 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room
temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD.
BREAKER PANEL TO PRIMARY CONTROL PANEL
Responsibility: Electrician
BREAKER PANEL PRIMARY CONTROL PANEL
BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED
BREAKER 1PH
CONTROL POWER. DO NOT WIRE
TO GFCI OR SHUNT TRIP BREAKER.
Hot
Neutral
H1
N1120 V
15 A
Ground GND
1ST HOOD LIGHT BREAKER SHARED W/ CONTROL
POWER. SWITCH #1
WIRE TO VFD QUICK CONNECTOR
BREAKER 3PH
MCA:
MOCP:
LINE
LINE
Ground
PCU-1 SM-1
GND
L1
L2
LINE L3208 V
27.9 A
40 A
BREAKER 3PH
WIRE TO VFD QUICK CONNECTOR
MCA:
MOCP:
LINE
LINE
208 V
Ground
MAU-1 SM-2
GND
L4
L5
LINE L67.6 A
15 A
BREAKER PANEL TO FANS
Responsibility: Electrician
BREAKER PANEL FANS
POWER TO
CONDENSER
LINE
LINE208-230
20 Amps
MAU-1
LINE
COND 1
3 PHASE
POWER TO
CONDENSER
LINE
LINE208-230
30 Amps
MAU-1
LINE
COND 2
3 PHASE
CONTROL PANEL TO FANS
Responsibility: Electrician
PRIMARY PANEL FANS
Load Wiring
WIRE TO
VFD QUICK
WIRE TO
DISCONNECT
CONNECTOR
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
FLA:
HP:
VOLT:
PCU-101
LOAD LEG 1
LOAD LEG 2
GND GROUND
FAN:
SM-1
LOAD LEG 3
U1
V1
W1
22.3
7.500
208 V
Load Wiring BLACK
BLACK
BLACK
GREEN
WIRE TO
VFD QUICK
CONNECTOR WHITE
RED
FLA:
HP:
VOLT:
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
IF VFD MOUNTED IN
2ND PANEL, WIRE SF
SIGNAL FROM PANEL
WITH ECPM03.
U2
V2
W2
LOAD LEG 1
LOAD LEG 2
LOAD LEG 3
GND GROUND
MAU-101FAN:
SM-2
N1 120V NEUTRAL
120V HOT
N1
6.1
2.000
208 V
H1
POLLUTION
UNIT
COMM LINK
CONTROL
IF MULTIPLE PCUs ON JOB,
WIRE EACH CAT-5 IN DAISY
CHAIN LOOP, WITH END OF LINE
TERMINATOR ON LAST UNIT.
CAT-5 ETHERNET CABLE
EACH ADDITIONAL UNIT MUST
HAVE MODBUS ADDRESS SET.
INSIDE PCU
J3
ECPM03
J3
CONTROL PANEL TO ACCESSORY ITEMS
Responsibility: Electrician
CONTROL PANEL COMPONENT
ALL SWITCHES FACTORY WIRED
CAT-5 CONNECTION
CONTROL PANEL
SWITCHES
TO J4
CONTROL PANEL
HOOD LIGHTS
TO
1400 W MAX WIRE TO J-BOX ON TOP OF HOOD
B1
W1
GND
BLACK
WHITE
GREEN
HOOD LIGHTS 1
WIRE DIRECTLY TO COMMUNICATION
ROUTERCOMM
MODULE. NET REQUIRES 1) DHCP 2)
UDP PORT 1444 & 1445 OPEN FOR
CAT-5 ETHERNET CONNECTION
CONTROL PANEL
WORLD WIDE
TO
WEB
OUTBOUND TRAFFIC ONLY.
--
WIRE TO CONTROL BOARD. INSTALL
SENSOR IN ROOM AWAY FROM HEAT
SOURCES. DO NOT INSTALL SENSOR
CONTROL PANEL
ROOM TEMP
TO
SENSOR
ON THE CEILING GRID, SEE MANUAL.
GROUPS:
T1A
T1B ROOM TEMP
FACTORY WIRED TEMPERATURE
SENSOR. MOUNTED IN HOOD CAPTURE
CONTROL PANEL
CAPTURE VOLUME
TO
SENSOR VOLUME.
T2A
T2B HOOD 1
CAPTURE 1
FACTORY WIRED TEMPERATURE
SENSOR. MOUNTED IN HOOD CAPTURE
CONTROL PANEL
CAPTURE VOLUME
TO
SENSOR VOLUME.
T3A
T3B HOOD 1
CAPTURE 2
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN HOOD CAPTURE
CONTROL PANEL
CAPTURE VOLUME
TO
SENSOR VOLUME.
T4A
T4B HOOD 2
CAPTURE 1
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN SUPPLY PLENUM.
CONTROL PANEL
PSP SENSOR
TO
T5A
T5B HOOD 2
PSP TEMP
CONTROL PANEL
PSP LED
TO
LIGHTS WIRE TO J-BOX ON TOP OF PSP.
CONNECT TO RESPECTIVE HOOD
LIGHTING CIRCUIT. NOTE: DO NOT
HOOD
LIGHT
INPUT
MATCH
WIRE IN SERIES WITH HOOD LIGHTS.
BLACK
WHITE
GREEN
PSP LIGHTS
HOT
NEUTRAL
GROUND
CONTROL PANEL
GAS VALVE
TO
120V ONLY
ONLY ENERGIZED THROUGH LCD
HMI WHEN FIRE SYSTEM ARMED.
GAS
N1
HOT TO GAS VALVE
NEUTRAL
GAS SOLENOID
THE FOLLOWING CONNECTIONS
MAY OR MAY NOT BE
REQUIRED BASED ON JOBSITE
SPECIFICATIONS
CONTROL PANEL
EXTERNAL
SIGNAL FOR
SHUNT TRIP
ST TERMINAL IS ENERGIZED
IN FIRE CONDITION.
CONTROL PANEL
EXTERNAL
SIGNAL FOR
CONTACTOR COIL
KS TERMINAL IS DE-ENERGIZED
IN FIRE CONDITION.
ST
N1 NEUTRAL FROM SHUNT COIL
HOT TO SHUNT COIL SHUNT COIL
KS
N1 NEUTRAL_TO_CONTACTOR_COIL
HOT_TO_CONTACTOR_COIL CONTACTOR_COIL
SPARE CONTACTS WILL MAKE
CONTROL PANEL
ON/OFF WITH
DRY CONTACT
SUPPLY FAN
COMMON TO NORMALLY OPEN
WHEN SUPPLY FAN IS ON.
GROUP 1
SFC1
SFO1
COMMON
NORMALLY OPEN
SFC2
SFO2
COMMON
NORMALLY OPEN
CONTROL PANEL
EXTERNAL
TO
SWITCH
SIGNAL SWITCH THROUGH BMS
WILL ACTIVATE ZONE1 FANS AND
LIGHTS
H1
IO1
BMS SWITCH
C NO
CONTROL PANEL
GAS VALVE
TO
24V DC ONLY
ONLY ENERGIZED THROUGH LCD
HMI WHEN FIRE SYSTEM ARMED.
(NOT NEEDED IF USING 120V
GAS VALVE).
LGV
N1D
POSITIVE TO GAS VALVE
NEGATIVE
GAS SOLENOID
DESCRIPTION OF OPERATION:
6950327
Raising Cane's 1032
SC-311110MA
7/2/2025
INSTALL
ECP #1-2
3 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room
temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD.
CONTROL PANEL TO FIRE SYSTEM
Responsibility: ALARM CONTRACTOR
CONTROL PANEL COMPONENT
CONTROL PANEL
BUILDING
SIGNAL FOR
FIRE ALARM
PANEL
AL1
AL2
J9
BUILDING
ALARM PANEL
FIRE INPUT
WIRE DIRECTLY TO CORE CIRCUIT
BOARD. AL1 WILL MAKE AL2 IN FIRE
CONDITION.
CONTROL PANEL
BUILDING
SIGNAL FOR
TROUBLE TROUBLE RELAY CONTACTS WILL
MAKE TBC TO TBL IN TROUBLE
CONDITION.
BUILDING
ALARM PANEL
ALARM
TBC
TBL
COMMON
NORMALLY CLOSED
CONTROL PANEL TO FIRE SYSTEM
Responsibility: CERTIFIED INSTALLER
CONTROL PANEL COMPONENT
FIRE STAT SUPERVISED LOOP
May be mixed factory and field wiring. See
Installation Schematic. Multiple fire sensors
possible.
HIGH TEMP WIRE (842 F), PN: SLPCON-xFT
required for all Supervised Loop wiring in contact
with a hood. All other wiring shall be PN: 6320UL,
Belden or similar.
21
22
23
24
FS-01
BK WH
Fire Stat
FS-02
BK WH
Fire Stat
CONTROL PANEL
MOUNTED FIRE
TO DUCT
DETECTION
STAT(S)
FIRE STATS
CONTROL PANEL
SYSTEM PULL
TO FIRE
STATION
MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM
LOOP.
Multiple manual actuation possible.
Multiple manual actuation possible.
A Plug jumper with wires from pin1 to pin4 and from pin2 to
pin3 is mounted on J10, remove the jumpers and
wire in the supervised actuation loop.
Microswitch MS-01 is optional for fire
system interlock.
Auxiliary Interlock (AUX-01):
Wire AU1 / AU2 of adjacent Master FS panel(s) in each
manual activation loop for simultaneous activation. See Fire
system drawings for more information.
101
102
103
104
AUX-01
AU1 AU2
PULL STATION
MS-01
C NO
Micro SW
MAD-01
C NO
Manual
Actuation
Device
Adjacent
FS
Panel
CAT-5 CONNECTIONCONTROL PANEL
MASTER FS
TO
BOARD.
PLACE END OF LINE PLUG
EOL120AIN EMPTY JACK. PN: EOL120A
CORE PCB
ADDITIONAL DEVICES MAY BE INLINE.
ECPM03
UNLESS VFD, PCU,
OR OTHER COMPONENT IN SERIES.
J3 J5
J6
CONTROL PANEL
MASTER FS
TO
PANEL
WIRE TO LIKE TERMINALS IN ALL
CORE PANELS THAT MUST ACTIVATE
TOGETHER. SET MASTER & SLAVE
DIP SWITCHES PER FIRE SYSTEM
SHIELDED TWISTED PAIRINTERLOCK NETWORK MASTER CORE
MANUAL.
CA
CB
CC
BLACK
RED
SHIELD
CA
CB
CC
DESCRIPTION OF OPERATION:
6950327
Raising Cane's 1032
SC-311110MA
7/2/2025
INSTALL
ECP #1-3
Fire System #1 TANK FS - 4.0 / Remote - 4.0/4.0/4.0.
FS-1: MASTER
DESCRIPTION OF OPERATION:
6950327
Raising Cane's 1032
SC-311110MA
7/2/2025
INSTALL
ECP #1-4
Fire System #1 TANK FS - 4.0 / Remote - 4.0/4.0/4.0.
FS-1: MASTER
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.14
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
DESCRIPTION OF OPERATION:
6950327
Raising Cane's 1032
SC-311110MA
7/2/2025
INSTALL
ECP #1-5
Fire System #1 TANK FS - 4.0 / Remote - 4.0/4.0/4.0.
FS-1: MASTER
WH
BK
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
FACTORY WIRING
SCHEMATIC
CIRCUIT BOARDS
MOTOR POWER CIRCUIT
PANEL LID
COMPONENT LIST
LABEL DESCRIPTION
PN:
ST-X
varies
Starter
PN:
OL-X
varies
Overload
PN:
C-X
varies
Contactor
PN:
TS-x
A/CP-PO-T4"-EXPL
Duct Thermostat
120 VAC
RELAY
RA-x
24 VDC
RELAY
RD-x
PN:
PS-1
MDP18-24A-1C
Power Sup. 24VDC
BK
PN:
RA-x
34.110.0184.0
120V Relay DPDT
WH
PN:
RA-x
34.110.0184.0
120V Relay DPDT
GR
UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG.
N1
H1
DC
-
GN
D
DC
+
8H1
7PCU
6ST
5KS
4KTS
3GAS
2AR1
1N1
120VJ9
5OV1
4SF1
3EF1
2B1
1IO1
120VJ7
AR1
H12x
N12x
B1
EF1
SF1
BK IO1
BK
BK
BK
JUMPERW1
BK 14AWG BK
64
RD-1
BL PRDC+RO1
PN:
RD-x
34.110.0188.0
24VDC Light Relay
BK WHSF1RA-2
RD-1
24V
1 2 3 4 5 6 7
8 9 10 11 12 13 14
J6
N1N1
RO
1
FAN
PANEL COOLING
DRY CONTACTS (SHOWN DE-ENERGIZED)
PCU AFM (field wired to end of line)
HOOD LIGHTS
J3
ECPM03/DAISY CHAIN
AR1 H1JUMPER FIRE SYSTEM
BK
BK
BK
GAS
KS
ST
NOTE: Configure for PCU AFM control
NOTE: Configure ECPM03 for CORE
J3
ECPM03/DAISY CHAIN
SM-1 SM-2
ECPM03
J10
IL
1
A
IL
1
B
JUMPER
MAKE UP AIR INTERLOCK.
1
2
11
1 JUMPER
1
2
11
1 JUMPER
NOTE: All items on ECPM03 J5 line to be daisy chained
from one component to the next, with EOL120A at end
of line. Place PN: EOL120A in empty RJ45 port.
J3
ECPM03 or Previous EOL
J5
MASTER CORE
RA-2-1
SFC1
SFO1
14 AWG
YW
RA-2-2
SFC2
SFO2
14 AWG
YW
24 X 18 X 8.62 BOX
CONTROL INPUT 120V
H1=LINE, N1=NEUTRAL, 15A
BREAKER. DO NOT CONNECT
TO SHUNT TRIP BREAKER.
SEE INSTALLATION
SCHEMATIC FOR ADDITIONAL
REQ.
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
YW- YELLOW
GY- GREY
PR- PURPLE
RD- RED
GR- GREEN
WH
/
B
L
BL
H1N1
DC
-
DC
+
LN
-+
PS-01
AC
24V
GN
D
DCKSKSBKKS
BK
BK
GAS
ST
BKEF1
PR
WH
GR
/
Y
W
WH
/
B
L
BL
J4 J5J4J5
FAN
SECONDARY PANEL COOLING IF NECESSARY
EF1 WHBK
J1
ECPM03
SCADA
WIRED BK
RD
+
-
DEST
DEST
ILB
ILC
ILA
DEST
DEST
TO ETH
CAT-5
PN:
SCADA SCADA Module
SHDANT
Wired to
Master CORE
(if applicable)
Use shielded wire
BK
RD
SD
JUMPER
ECPM03
J10
IL
2
A
IL
2
B
TERMINAL GAS USED FOR
120V POWERED GAS VALVES
ONLY
N1
6950327
Raising Cane's 1...
FACTORY
SC-311110MA
7/2/2025
ECP #1-6
3 Phase w/ control for 1 Exhaust
Fan, 1 Supply Fan, Exhaust on in
Fire, Lights out in Fire, Relay On/Off
with Supply Fan, Fan(s) On/Off
Thermostatically Controlled. Room
temperature sensor shipped loose
for field installation. INVERTER
DUTY 3 PHASE MOTOR
REQUIRED FOR USE WITH VFD.
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
U/T1
V/T2
W/T3
L1
L2
L3/N
GR
GR
GND
VFD:
HP:
MTR:
FLA:
P107:
P108:
P410:
P150:
P100:
P194:
P101:
P131:
P167:
P103:
P102:
L1
L2
L3
10 AWG
3 PH
40 A
208 V
U1
V1
W1
SM-1
ESV552N02TXB571 225
01
01
11
96
00
22.3
7.500
PCU-1
N/A
N/A
76.1
75.0
0.0
GND
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
U/T1
V/T2
W/T3
L1
L2
L3/N
GR
GR
GND
VFD:
HP:
MTR:
FLA:
P107:
P108:
P410:
P150:
P100:
P194:
P101:
P131:
P167:
P103:
P102:
L4
L5
L6
14 AWG
3 PH
15 A
208 V
U2
V2
W2
SM-2
ESV152N02YXB571 225
01
01
21
87
00
6.1
2.000
MAU-1
N/A
N/A
52.6
49.2
0.0
GND
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
FACTORY WIRING
SCHEMATIC
CORE FIRE
PROTECTION
COMPONENT LIST
LABEL DESCRIPTION
120 VAC
RELAY
RA-x
24 VDC
RELAY
RD-x
24 VOLT BATTERY PACK
5 AMP FUSE
RD
SHIELDED TWISTED PAIR
PCB-2
J3-2
J4-1
J3-11
J4-3
J4-2
J4-8
J4-9
J4-12
J3-14
J4-5
J3-13
J3-4
J4-6
J3-10
J2-1
J2-2
J2-3
J2-4
J7-2
J7-3
J7-1
J3-1 J3-3
RD
RD BR
RD
MAX 16AWG
RD BK
ORRD
PKRD
BRRD
RD OR/BL
BK 18AWG
BK
BK
J3-5
J1-1
J1-2
RD
BK
BK
RD
FIRE STAT SUPERVISED LOOP
May be mixed factory and field wiring. See
Installation Schematic. Multiple fire sensors
possible.
+
+
RD
BK
BK
RD
Shield
BK
RD
RS-485 CORE INTERLOCK
NETWORK. Connection to other
CORE Panels or Communication
Module. See Installation Schematic
for Connection.
N1D 3xH1D3x
DISCONNECT J1
21
22
23
24
16AWG
WHN1
H1
PN: 1606-XLP-60EQ
Adjust power supply to 27.5 Volts with an
accurate Digital Volt Meter or with an HMI
plugged into the CORE board.
NL
+-
PS-02 60W
GR
BK
GND
PN:
PCB-2
PCBCORE-APP
CORE PCB
PN:
PS-02
1606-XLP-60E
CORE POWER SUPPLY
PN:
WS-x
varies
Water Solenoid
PN:
LT-06
WL-1090D1-28V
24V Red Ind. Light
PN:
LL-01
AQ5510
Surf. Level Sensor
PN:
AA-01
SCE120LA3FP1B
Audible Alarm
PN:
PB-XX
ZB4BA2/ZB4BZ1015
Prime/Reset Switch
PN:
SW-04
BZ-2RQ1-A2
Tamper Switch
PN:
SP-1
50000-805
Surfactant Pump
PB-01
Prime / Reset
RD-20
Trouble Relay
RD-17
Fire Relay
DRY CONTACTS (SHOWN DE-ENGERGIZED)
AA-01
Audible Alarm
SW-04
Door Tamper Switch
C NO
FS-01
BK WH
Fire Stat
FS-02
BK WH
Fire Stat
HIGH TEMP WIRE (842 F), PN:
SLPCON-xFT required for all
Supervised Loop wiring in contact with
a hood. All other wiring shall be PN:
6320UL, Belden or similar. Factory
mounted hood sensors will be
terminated at junction box on top of
hood.
PN:
GV-1
varies
24v DC Gas Valve
INTERLOCK FOR AUTOMAN ACTIVATION. Used
for activating 120V automan or adjacent Master
CORE panels during active Fire Condition.
RD-18-1
YW
J3-16
J3-8
LT-6
R
FIRE INDICATOR
DIP Switch
ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD
BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES.
RD/GNRDRD-19
Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS
Kill Switch, wire EKC and EKS terminals to like
terminals in UDS panel.
RD-19-1
EKC
EST
EKS
YW
INTERLOCK FOR AUTOMAN ACTIVATION. Used
for activating 120V automan or adjacent Master
CORE panels during active Fire Condition.
RD-18-1
YW
RD OR/BLRD-18
Auxiliary Interlock Relay
PN:
FS-XX
12-F28021-000360
Duct Fire Sensor
PN:
LT-05
WL-1090D3-28V
24V YLW Ind. Light
PN:
PS-01
Station STI-SS2431
Remote Puill/Push
FOR SHIPMENT
J10-1
J10-2
J10-3
J10-4
RD
BK
BK
RD
101
102
103
104
MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM
LOOP.
Multiple manual actuation possible.
A Plug jumper with wires from pin1 to pin4 and from pin2 to
pin3 should be mounted on J10 if there is no manual
actuation device and no microswitch.
MAD-01
C NO
Manual
Actuation
Device
MS-01
C NO
Micro SW
1 2 3 4 5 6 7 8
SW
1
ON
PUT END OF LINE PLUG IN EMPTY RJ45
J3
ECPM03
UNLESS PCU AFM OR OTHER COMPONENT IN SERIES.
CAT-5 WIRING (MASTER ONLY)
FIELD WIRED IF REMOTE PREWIRE
PN:
RD-XX
PLC-RPT-24DC/21
24VDC Phoenix Relay
AUX-01
AU1 AU2
Auxiliary Interlock (AUX-01):
Wire AU1 / AU2 of adjacent Master CORE panel(s) in each
manual activation loop for simultaneous activation.
AU1/AU2 will have continuity for 10 seconds if adjacent panel
goes into fire condition, activating this CORE Panel but
allowing for a reset after 10 seconds.
NOTE: AU1/AU2 terminals of CORE Panel should not be
wired into its own manual activation loop.Adjacent
CORE Panel
Master CORE set DIP
SW 8 to CLOSED
position. Slave CORE
with address 1 set
DIP SW 8 to
CLOSED position. All
other CORES set DIP
SW 8 OPEN.
18AWG
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
YW- YELLOW
GY- GREY
PR- PURPLE
RD- RED
GR- GREEN
FIRE INDICATOR FAULT CONDITION FLASH CODES
2 Release Solenoid
3 Pressure Switch
4 Auxiliary Fault
5 Microcontroller Fault
6 N/A
7 Supervised Loop
8 Ground Fault
9 Surfactant Low
10 Battery Voltage Low
11 AC Power Failure
12 Door Tamper Switch
13 Test Mode
14 CORE Interlock Network
15 Fault on Hood in Interlock Network
16 Fault on PCU in Interlock Network
FIRE ALARM SYSTEM DRY CONTACTS. Termials
AL1 & AL2 make in FIRE.
To Building Fire Alarm
Panel
J9
AL1
AL2
J3-7
FIRE SYSTEM DRY CONTACTS.
Dry contacts will make C2 to AR2 when system is
armed.
RD-17-1
C2
AR2
14 AWG
YW
TROUBLE RELAY. Contact terminals TBC & TBL
make if there is trouble. Contact terminals TBC &
TOK make if the system is ok.
RD-20-1
TBC
TBL
TOK
YW
PR RS
SW-05-1
Test Armed
3 4 YW RS-1
RELEASE SOLENOID
BLBR
RD ORSW-05-3
Test Armed
3 4 J4-13
PN:
SW-05
ZB5AD2
TEST/ARM Switch
J3-10
J3-7
PR RS2
SW-05-2
Test Armed
3 4 YW RS-2
RELEASE SOLENOID
BLBR
J4-9RDPSORJ4-9
PS-1
PSX
WH
WH
RD
PN:
PWS-01
24VDC 18W POWER
24VDC Power Suppl
CA
CB
CC
AU1AU1
AU2AU2
TR2
PN:
MAD-01
DEVICE
MANUAL ACTIVATION
GAS VALVES SHOULD BE WIRED TO
MASTER CORE BOARD ONLY.
RDRD
GV-1
24V DC Gas ValveLGVPK TERMINAL LGV USED FOR 24VDC
POWERED GAS VALVES ONLY.
PS-X
QTY-1
Pressure
Switches
PS-1
WIRED IN SERIES. A TERMINAL BLOCK SHOULD
BE ADDED BETWEEN EACH PRESSURE SWITCH
PRESSURE SWITCHES SHOULD BEQTY-2
(2nd Contact)
6950327
Raising Cane's 1...
FACTORY
SC-311110MA
7/2/2025
ECP #1-7
Fire System #1 TANK FS - 4.0 /
Remote - 4.0/4.0/4.0.
FS-1: MASTER
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
FACTORY WIRING
SCHEMATIC
CORE FIRE
PROTECTION
COMPONENT LIST
LABEL DESCRIPTION
120 VAC
RELAY
RA-x
24 VDC
RELAY
RD-x
24 VOLT BATTERY PACK
5 AMP FUSE
RD
SHIELDED TWISTED PAIR
PCB-2
J3-2
J4-1
J3-11
J4-3
J4-2
J4-8
J4-9
J4-12
J3-14
J4-5
J3-13
J3-4
J4-6
J3-10
J2-1
J2-2
J2-3
J2-4
J7-2
J7-3
J7-1
J3-1 J3-3
RD
RD BR
RD
MAX 16AWG
RD BK
ORRD
PKRD
BRRD
RD OR/BL
BK 18AWG
BK
BK
J3-5
J1-1
J1-2
RD
BK
BK
RD
FIRE STAT SUPERVISED LOOP
May be mixed factory and field wiring. See
Installation Schematic. Multiple fire sensors
possible.
+
+
RD
BK
BK
RD
Shield
BK
RD
RS-485 CORE INTERLOCK
NETWORK. Connection to other
CORE Panels or Communication
Module. See Installation Schematic
for Connection.
N1D 3xH1D3x
DISCONNECT J1
21
22
23
24
16AWG
WHN1
H1
PN: 1606-XLP-60EQ
Adjust power supply to 27.5 Volts with an
accurate Digital Volt Meter or with an HMI
plugged into the CORE board.
NL
+-
PS-02 60W
GR
BK
GND
PN:
PCB-2
PCBCORE-APP
CORE PCB
PN:
PS-02
1606-XLP-60E
CORE POWER SUPPLY
PN:
WS-x
varies
Water Solenoid
PN:
LT-06
WL-1090D1-28V
24V Red Ind. Light
PN:
LL-01
AQ5510
Surf. Level Sensor
PN:
AA-01
SCE120LA3FP1B
Audible Alarm
PN:
PB-XX
ZB4BA2/ZB4BZ1015
Prime/Reset Switch
PN:
SW-04
BZ-2RQ1-A2
Tamper Switch
PN:
SP-1
50000-805
Surfactant Pump
PB-01
Prime / Reset
RD-20
Trouble Relay
RD-17
Fire Relay
DRY CONTACTS (SHOWN DE-ENGERGIZED)
AA-01
Audible Alarm
SW-04
Door Tamper Switch
C NO
FS-01
BK WH
Fire Stat
FS-02
BK WH
Fire Stat
HIGH TEMP WIRE (842 F), PN:
SLPCON-xFT required for all
Supervised Loop wiring in contact with
a hood. All other wiring shall be PN:
6320UL, Belden or similar. Factory
mounted hood sensors will be
terminated at junction box on top of
hood.
PN:
GV-1
varies
24v DC Gas Valve
INTERLOCK FOR AUTOMAN ACTIVATION. Used
for activating 120V automan or adjacent Master
CORE panels during active Fire Condition.
J3-16
J3-8
LT-6
R
FIRE INDICATOR
DIP Switch
ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD
BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES.
RD/GNRDRD-19
Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS
Kill Switch, wire EKC and EKS terminals to like
terminals in UDS panel.
RD-19-1
EKC
EST
EKS
YW
INTERLOCK FOR AUTOMAN ACTIVATION. Used
for activating 120V automan or adjacent Master
CORE panels during active Fire Condition.
RD OR/BLRD-18
Auxiliary Interlock Relay
PN:
FS-XX
12-F28021-000360
Duct Fire Sensor
PN:
LT-05
WL-1090D3-28V
24V YLW Ind. Light
PN:
PS-01
Station STI-SS2431
Remote Puill/Push
FOR SHIPMENT
J10-1
J10-2
J10-3
J10-4
RD
BK
BK
RD
101
102
103
104
MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM
LOOP.
Multiple manual actuation possible.
A Plug jumper with wires from pin1 to pin4 and from pin2 to
pin3 should be mounted on J10 if there is no manual
actuation device and no microswitch.
MAD-01
C NO
Manual
Actuation
Device
MS-01
C NO
Micro SW
1 2 3 4 5 6 7 8
SW
1
ON
PUT END OF LINE PLUG IN EMPTY RJ45
J3
ECPM03
UNLESS PCU AFM OR OTHER COMPONENT IN SERIES.
CAT-5 WIRING (MASTER ONLY)
FIELD WIRED IF REMOTE PREWIRE
PN:
RD-XX
PLC-RPT-24DC/21
24VDC Phoenix Relay
AUX-01
AU1 AU2
Auxiliary Interlock (AUX-01):
Wire AU1 / AU2 of adjacent Master CORE panel(s) in each
manual activation loop for simultaneous activation.
AU1/AU2 will have continuity for 10 seconds if adjacent panel
goes into fire condition, activating this CORE Panel but
allowing for a reset after 10 seconds.
NOTE: AU1/AU2 terminals of CORE Panel should not be
wired into its own manual activation loop.Adjacent
CORE Panel
Master CORE set DIP
SW 8 to CLOSED
position. Slave CORE
with address 1 set
DIP SW 8 to
CLOSED position. All
other CORES set DIP
SW 8 OPEN.
18AWG
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
YW- YELLOW
GY- GREY
PR- PURPLE
RD- RED
GR- GREEN
Wired to
PCU AFM
Master CORE
Wired to
FIRE INDICATOR FAULT CONDITION FLASH CODES
2 Release Solenoid
3 Pressure Switch
4 Auxiliary Fault
5 Microcontroller Fault
6 N/A
7 Supervised Loop
8 Ground Fault
9 Surfactant Low
10 Battery Voltage Low
11 AC Power Failure
12 Door Tamper Switch
13 Test Mode
14 CORE Interlock Network
15 Fault on Hood in Interlock Network
16 Fault on PCU in Interlock Network
FIRE ALARM SYSTEM DRY CONTACTS. Termials
AL1 & AL2 make in FIRE.
To Building Fire Alarm
Panel
J9
AL1
AL2
J3-7
FIRE SYSTEM DRY CONTACTS.
Dry contacts will make C2 to AR2 when system is
armed.
RD-17-1
C2
AR2
14 AWG
YW
TROUBLE RELAY. Contact terminals TBC & TBL
make if there is trouble. Contact terminals TBC &
TOK make if the system is ok.
RD-20-1
TBC
TBL
TOK
YW
RD PS OR J4-9
PN:
PS
EWC-PRESSURE
Pressure Switch
PR RS
SW-05-1
Test Armed
3 4 YW RS-1
RELEASE SOLENOID
BLBR
RD ORSW-05-3
Test Armed
3 4 J4-13
PN:
SW-05
ZB5AD2
TEST/ARM Switch
CAT-5
SCADA
TO ETH
BK
RD
+
-
PN:
SCADA SCADA Module
WIRED
ANT
RS2PRSW-05-2
Test Armed
3 4 YW
PS-1
Pressure Switch
WH
WH
/
B
L
BL
H1N1
DC
-
DC
+
LN
-+
PWS-01
AC
24V
DC
PN:
PWS-01
24VDC 18W POWER
24VDC Power Suppl
CA
CB
CC
AU1AU1
AU2AU2
TR2
CC
CB
CA
PN:
MAD-01
DEVICE
MANUAL ACTIVATION
GAS VALVES SHOULD BE WIRED TO
MASTER CORE BOARD ONLY.
RDRD
GV-1
24V DC Gas ValveLGVPK TERMINAL LGV USED FOR 24VDC
POWERED GAS VALVES ONLY.
H1
CB-01
BK
CB-01 INSIDE ECP BOX, WIRED TO UCPCU
BK TO UCPCU
PN:
CB-01
S201U-K15
15A Circuit Breaker
(2nd Contact)
BK WHH1 N1
FAN
PANEL COOLING
*POWER FROM H1/N1 ONLY ON STANDALONE PACKAGE W/O ECP
6950327
Raising Cane's 1...
FACTORY
PCU-CAS-TANK
7/2/2025
ECP #2-1
PCU Tank-based Fire Protection
System equipped with Electronic
Detection, and Electronic Activation,
utilizing CORE board as a Listed
Release Mechanism. Installed in
Utility Cabinet with integral prewire
panel.
12 X 18 X 8.62 Box
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.15
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.16
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
HORIZONTAL VERTICAL
TYPE
DUCT DIAMETER SUPPORT SPACING (FT)
2R (18")
8"7'
10"7'
12"7'
14"7'
16"7'
18"5'
20"5'
22"5'
DOUBLE WALL FACTORY BUILT DUCTWORK
- ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW.
- FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE ENTIRE INSTALLATION AND OPERATION MANUAL
- DUCTWORK SHALL SLOPE NOT LESS THAN 1/16" PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR.
- WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16" PER LINEAR FOOT.
24"5'
WALL
SUPPORT (FT)
CURB
SUPPORT (FT)
FLOOR
SUPPORT (FT)
18'24'24'
3R & 3Z (5"-24")10'24'24'
3Z (26" -36")10'20'20'
26"5'
28"5'
30"5'
32"5'
34"5'
36"5'
2R & 2R HT (5"-16")20'24'24'
7"7'
6"7'
5"7'
DO NOT LEAK TEST USING SMOKE BOMBS CONTAINING
CHLORINES/CHLORIDES. CONSULT WITH CAPTIVEAIRE
FOR PROPER LEAK TESTING METHODS.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.17
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
20"
DW1620SADKIT - HORIZONTAL SUPPORTS
28"
DW2428SADKIT - HORIZONTAL SUPPORTS
DW2026DWCHASESUPASY - CHASEWAY SUPPORT
5" MAX
34 1/4"
34 1/4"
30"
DW2630SADKIT - HORIZONTAL SUPPORTS
SUPPORT SYSTEM DETAILS #1
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.18
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
H1-E1 H1-E2H2-E1
P10 P12 P13 P23 P24 P25
P26
P27
P28
P29
P3
P32
P33
P34
P35
P36P4P5P6P7P8P9
45.1"
176.5"MAX
169"
162"MIN
115.5"MAX
112"
78"MIN
82.1"
45.06"
41.00
102.8"36.95"15.79"29.22"17.79"
247.6"
16.79"
139.5"MAX
136"
102"MIN
141.5"MAX
138"
104"MIN
152.5"MAX
149"
115"MIN
152.5"MAX
149"
115"MIN
45.06"
176.5"MAX
169"
162"MIN
115.5"MAX
112"
78"MIN
82.1"
45.1"
41.00
102.8"36.95"15.79"29.22"17.79"
247.6"
16.79"
139.5"MAX
136"
102"MIN
141.5"MAX
138"
104"MIN
152.5"MAX
149"
115"MIN
152.5"MAX
149"
115"MIN
176.5"MAX
169"
162"MIN 45.1"45.06"
115.5"MAX
112"
78"MIN
82.1"
41.00
102.8"36.95"15.79"29.22"17.79"
247.6"
16.79"
139.5"MAX
136"
102"MIN
141.5"MAX
138"
104"MIN
152.5"MAX
149"
115"MIN
152.5"MAX
149"
115"MIN
DUCTWORK #1 FRONT VIEW
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.19
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
H1-E1 H2-E1
P1
P16P17P19
P2P22
P26
P27
P28
P33
P35
P37 P4
92.5"MAX
70"
55"MIN 65.2"
47.5"MAX
42"
33"MIN
115.5"MAX
112"
78"MIN
28.5"MAX
23"
14"MIN
157.5"MAX
135"
120"MIN
92.5"MAX
70"
55"MIN 65.2"
47.5"MAX
42"
33"MIN
115.5"MAX
112"
78"MIN
28.5"MAX
23"
14"MIN
157.5"MAX
135"
120"MIN
47.5"MAX
42"
33"MIN65.2"
92.5"MAX
70"
55"MIN
115.5"MAX
112"
78"MIN
28.5"MAX
23"
14"MIN
157.5"MAX
135"
120"MIN
DUCTWORK #1 SIDE VIEW
P1
P10 P12 P13
P14
P15
P17
P18
P19
P2
P20P21P22 P23 P24 P25
P3
P32P33 P34 P35
P36
P37
P4 P5 P6 P7 P8P9
45.05"
92.5"MAX
70"
55"MIN
65.01"
176.5"MAX
169"
162"MIN
47.5"MAX
42"
33"MIN
82.01"
45.01"45.01"
92.5"MAX
70"
55"MIN
65.01"
176.5"MAX
169"
162"MIN
47.5"MAX
42"
33"MIN
82.01"
45.05"
47.5"MAX
42"
33"MIN
176.5"MAX
169"
162"MIN
65.01"
92.5"MAX
70"
55"MIN
45.05"45.01"
82.01"
DUCTWORK #1 TOP VIEW
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.20
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A
H1-E1
H1-E2
H2-E1
P1
P10
P12
P13 P14
P15 P16 P17 P19
P2
P20
P21
P22
P23
P24
P25
P26
P27
P28
P29
P3
P30
P32
P33
P35
P36
P37
P4
P5
P6
P7
P8
P9
DUCTWORK #1 SE VIEW
SYSTEM DESIGN VERIFICATION (SDV)
IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS HAD A
COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL. TYPICALLY, THE SDV WILL BE PERFORMED AFTER
ALL INSPECTIONS ARE COMPLETE.
ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE
ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES
WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO
RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND
BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY THAT CANNOT
BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP CHARGES.
DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER. SHOULD A
RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE SALES OFFICE WILL BE NOTIFIED. THERE
WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
6950327
MASTER DRAWING
Ra
i
s
i
n
g
C
a
n
e
'
s
1
0
3
2
SA
N
T
A
A
N
A
,
C
A
,
9
2
7
0
1
Lo
u
i
s
i
a
n
a
O
f
f
i
c
e
59
0
4
0
A
m
b
e
r
S
t
r
e
e
t
,
S
u
i
t
e
B
,
S
l
i
d
e
l
l
,
L
A
,
7
0
4
6
1
P
H
O
N
E
:
(
9
8
5
)
7
8
1
-
4
1
0
7
F
A
X
:
9
1
9
7
4
7
5
6
3
7
E
M
A
I
L
:
r
e
g
2
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
M3.21
HOOD DRAWINGS
Te
l
e
:
9
7
2
-
7
6
9
-
3
1
0
0
F
a
x
:
9
7
2
-
7
6
9
-
3
1
0
1
68
0
0
B
i
s
h
o
p
R
o
a
d
,
P
l
a
n
o
,
T
X
7
5
0
2
4
Date:
Project Number:
Sheet Number:
Drawn By:
Store:
Re
s
t
a
u
r
a
n
t
S
u
p
p
o
r
t
O
f
f
i
c
e
RAC23003.0
07.12.2024
MAM & JJD
Sheet Title:
1
07.01.2024 VERSION 2024-1.0 RELEASE
Prototype :
Date Issued:Bulletin Number:
Design Bulletin Updates:
Prototype Issue Date:
-
2
3
REVISIONS:
4
5
6
7
A
9
Kitchen Issue Date:
10
Raising Cane's
Restaurant #C1032
1303 N. Bristol st.
Santa Ana, CA 92706
P6E-HV Scheme B
09
/
1
2
/
2
0
2
5
P
E
R
M
I
T
R
E
V
I
S
I
O
N
-
B
U
L
L
E
T
I
N
1
09/05/24 BLDG. SUBMITTAL
PERMIT SET
P6E-AV SCHEME B 2024-1.0
07.01.2024
Check By:MMM
07.01.2024
09/27/24 PLANNING RESPONSE
11/01/24 HEALTH DEP. RESUBMITTAL
12/12/24 HEALTH DEP. RESUBMITTAL
1/20/25 BUILDING. RESUBMITTAL
2/21/25 BUILDING. RESUBMITTAL
05/02/2025 BID SET
06/25/2025 CONSTRUCTION SET
09/12/2025 PERMIT REVISION
Professional of Record:
19401 40TH AVE W
SUITE 420
LYNNWOOD, WA 98036
CONTACT: MARK MANGLICMOT, P.E.
(425) 516-7882
MMANGLICMOT@PMDGINC.COM
09/12/25
MARK MANGLICMOT, PE
A