Loading...
HomeMy WebLinkAbout1303 N Bristol St - REV 1 - PlanSITE 49,085 S.F. 2,973 S.F. BUILDING CODE REFERENCE CODE ELECTRICAL CODE PLUMBING CODE MECHANICAL CODE FIRE CODE ENERGY CODE ACCESSIBILITY CODE GREEN BUILDING CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA BUILDING CODE CHAPTER 11B 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE - CAL GREEN SITE STATISTICS *SEE CIVIL DRAWINGS FOR ALL OTHER SITE INFORMATION NOT SHOWN ON THIS COVER SHEET PARKING STATISTICS 2021 CALIFORNIA RETAIL FOOD CODEHEALTH CODE SCOPE OF WORK:RESTROOM PLUMBING FIXTURES SEE SHEET CRA FOR RESTROOM PLUMBING FIXTURE REQUIREMENTSGROUND UP CONSTRUCTION OF A NEW RESTAURANT WITH ATTACHED CORRAL OUTDOOR PATIO COVER AREA. INCLUDED IN THIS WORK UNDER THIS PERMIT ARE THE FOLLOWING: 1.DRIVE-THRU WINDOW CANOPY 2.MENU BOARD FOOTINGS AND CANOPY 3.OUTDOOR PATIO COVER 4.TRASH ENCLOSURE WITH METAL COVER 5.LIGHT POLE FOOTINGS 6.DRIVE-THRU EQUIPMENT FOOTINGS 7.LANDSCAPE AND IRRIGATION 1.REFER TO SHEET GN1.0 FOR GENERAL NOTES AND REFER TO SHEET GN1.1 FIRE DEPT. & HEALTH DEPT. NOTES 2.THE STATED DIMENSIONS SHALL TAKE PRECEDENCE OVER GRAPHICS. DO NOT SCALE THE DRAWINGS. THE ARCHITECT SHOULD BE NOTIFIED OF ANY DISCREPANCIES. 3.DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS ARE NOT INTENDED AND SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR OWNER PRIOR TO CONTINUING WITH THE AFFECTED PORTIONS OF THE WORK. 4.THE BIDDING AND CONSTRUCTION OF THE PROJECT WILL BE ADMINISTERED BY THE OWNER. 5.THE APPROVED PLANS (FOR CONSTRUCTION) SET SHALL BE KEPT ON SITE AT ALL TIMES, INCLUDING ALL ADDENDA, SUPPLEMENTAL INSTRUCTIONS, CHANGE ORDERS AND COPIES OF APPROVED SUBMITTALS. 6.AT ALL TIMES, THE GENERAL CONTRACTOR SHALL CLOSELY SUPERVISE THE WORK OF ALL SUBCONTRACTORS AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS & TECHNIQUES, INCLUDING SAFETY PROCEDURES AND / OR COORDINATING / SEQUENCING ALL TRADES. 7.THE GENERAL CONTRACTOR IS RESPONSIBLE TO CARRY WORKMEN'S COMPENSATION AS REQUIRED BY LAW AND / OR GOVERNING AUTHORITY, 8.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE SAFETY & CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION. 9.THE GENERAL CONTRACTOR SHALL ADHERE AND COMPLY WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS REGARDING JOB SITE SAFETY. 10.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK AND THAT OF HIS SUBCONTRACTORS FOR LOSSES AND DAMAGES TO EQUIPMENT, TOOLS AND MATERIALS USED IN CONJUNCTION WITH THE WORK FOR FOR ACTS OF HIS EMPLOYEES AND ALL SUBCONTRACT WORKERS. 11.CLEANING: THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE OF CONSTRUCTION DEBRIS & TRASH. *SEE CIVIL DRAWINGS FOR ALL OTHER SITE INFORMATION NOT SHOWN ON THIS COVER SHEET A ANNEALED AC AIR CONDITIONING ACT ACOUSTIC CEILING TILE AFF ABOVE FINISH FLOOR AHU AIR HANDLING UNIT AL ALUMINUM BLCKG BLOCKING ASPH ASPHALT CJ CONTROL JOINT CLNG CEILING CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONT CONTINUOUS CPT CARPET CT CERAMIC TILE CL CENTERLINE DBL DOUBLE DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DWG DRAWING DS DOWNSPOUT EA EACH EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATION EQ EQUAL EXIST EXISTING FD FLOOR DRAIN FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISH FLOOR FR FIRE RATED FRP FIBERGLASS REINFORCED PLASTIC GALV GALVANIZED GYP BD GYPSUM BOARD HC HANDICAP HDW HARDWARE HM HOLLOW METAL HT HEIGHT HVAC HEATING,VENTILATION, AIR CONDITIONING INSUL INSULATION MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MO MASONRY OPENING MR MOISTURE RESISTANT MTL METAL NA NOT APPLICABLE NIC NOT IN CONTRACT NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OPP OPPOSITE PF PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PT PRESSURE TREATED PTD PAINTED QT QUARRY TILE R RADIUS REBAR REINFORCING BAR REF REFERENCE REQ'D REQUIRED RO ROUGH OPENING SF STOREFRONT SB SPLASHBLOCK SIM SIMILAR SPEC SPECIFICATION SS STAINLESS STEEL STL STEEL STOR STORAGE SUSP SUSPENDED T TEMPERED TYP TYPICAL UNO UNLESS NOTED OTHERWISE VCT VINYL COMPOSITION TILE VERT VERTICAL WD WOOD WP WATERPROOF WWF WELDED WIRE FABRIC LANDLORD CIVIL ENGINEER KIESEL DESIGN 422 E. MAIN STREET VENTURA, CA 93001 PHONE: 805-947-0730 CONTACT: JACK KIESEL jack@kieseldesign.com LANDSCAPE ARCHITECT MEP ENGINEER STRUCTURAL ENGINEER SIGNS & AWNINGSSOILS ENGINEER TERRACON 50 GOLDENLAND CRT. STE. 100 SACRAMENTO, CA 95834 PHONE: 916-246-5096 CONTACT: STAYSHA DELGADO staysha.delgado@terracon.com ARCHITECTTENANT UTILITY CONSULTANT E4 324 Avenida De La Estrella, Ste B SAN CLEMENTE, CA 92672 PHONE: 949-353-5134 CONTACT: NICOLE CAPLAN nicole@4design.com PROJECT COVER SHEET PCS WRIGHT ENGINEERS 2 VENTURE, SUITE 200 IRVINE, CA 92618 PHONE:949-477-4001 FAX:559-323-9633 CONTACT: TOM ALLEN tallen@wrightengineers.com 2022 CALIFORNIA ELECTRICAL CODE 32,549 S.F. 13,369 S.F. CITY OF SANTA ANA MUNICIPAL CODEMUNICIPAL CODE 1.SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE, WHO SHALL REVIEW THEM AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. 2.PLANS FOR THE DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED IN A TIMELY MANNER THAT ALLOWS A MINIMUM OF 30 DAYS FOR INITIAL PLAN REVIEW. ALL COMMENTS RELATED TO THE DEFERRED SUBMITTAL MUST BE ADDRESSED TO THE SATISFACTION OF THE PLAN CHECK DIVISION PRIOR TO APPROVAL OF THE SUBMITTAL ITEMS. 3.DEFERRED ITEMS SHALL BE SUBMITTED BY THE GENERAL CONTRACTOR TO THE LOCAL JURISDICTION FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING: 1.SIGNAGE AND MENU BOARD 2.FIRE SPRINKLERS 3.FIRE ALARM 4.FIRE SERVICE UNDERGROUND SYSTEM 5.C02. SP1 BRISTOL STREET CORRIDOR RESTAURANT #C1032 1303 N Bristol St. Santa Ana, CA 92706 P6E-AV- SCHEME B 03 A R C H I T E C T U R A L 07 P L U M B I N G 08 E L E C T R I C A L 01 G E N E R A L FRAMING PLANA1.20 DOOR SCHEDULE & ELEVATIONSA2.10 FINISH FLOOR PLAN A3.20 INTERIOR ELEVATIONSA5.20 RESTROOM PLAN AND ELEVATIONS BUILDING SECTIONSA6.10 WALL SECTIONSA7.10 WALL SECTIONS WALL SECTIONS WALL SECTIONS A8.20 REFLECTED CEILING PLANA1.30 ROOF PLANA1.50 PROJECT COVER SHEET PCS SLAB COORDINATION PLANA1.21 KEYNOTE FLOOR PLANA1.10 TRASH ENCLOSURE PLAN & DETAILS A0.21 DOOR DETAILSA2.11 WINDOW SCHEDULE & ELEVATIONSA2.20 A3.10 FINISH SCHEDULE EXTERIOR ELEVATIONSA4.10 EXTERIOR ELEVATIONSA4.20 INTERIOR ELEVATIONSA5.10 A5.30 A7.20 A7.30 A7.40 PLAN DETAILSA8.10 SECTION DETAILS A8.30 INTERIOR DETAILS A8.31 INTERIOR DETAILS ENLARGED REFLECTED CEILING PLANA1.31 WINDOW DETAILSA2.21 ROOF FRAMING PLANS2.1 FOUNDATION DETAILSS4.1 S4.2 FRAMING DETAILS HVAC FLOOR PLANM1.1 HVAC SCHEDULES AND DETAILSM2.1 KITCHEN HOOD DETAILS AND HVAC SPECS.M3.1 WATER PLUMBING PLANP1.1 ROOF PLUMBING PLANP2.1 WASTE, VENT & GAS RISER DIAGRAMP3.1 PLUMBING DETAILSP4.1 PLUMBING SPECIFICATIONSP6.1 ELECTRICAL SITE PLAN POWER FLOOR PLANE2.1 LIGHTING FLOOR PLAN RISERS, SCHEDULES AND DETAILSE3.1A LIGHTING FIXTURE SCHEDULEE3.2 ELECTRICAL DETAILS ELECTRICAL SPECIFICATIONSE4.2 EQUIPMENT FLOOR PLANFS1.10 EQUIPMENT SCHEDULEFS2.10 EQUIPMENT KEY PLAN FS3.10 EQUIPMENT INTERIOR ELEVATIONSFS3.20 FS3.30 FS3.40 FS3.50 M3.2 P5.1 HVAC ROOF PLANM1.2 GREASE RECLAMATION DETAILSP7.1 E1.0 A8.40 ROOF DETAILS A8.21 SECTION DETAILS WINDOW DETAILSA2.22 PLUMBING CALCULATIONS ENLARGED ELEVATIONS & DETAILSA4.30 TRUSS COORDINATION PLANA1.40 WALL SECTIONSA7.50 WATER RISER DIAGRAMP3.2 E3.3 A0.20 ACCESSIBILITY SITE PLANA0.10 SEATING FLOOR PLANFS1.11 CO2 DETAILSP4.2 WALL SECTIONSA7.60 PATIO PLANA0.12 ACCESSIBILITY SITE DETAILSA0.11 SITE DETAILS INDEX OF DRAWINGS NOTESSH E E T TI T L E DI S C I P L I N E NOTESSH E E T TI T L E DI S C I P L I N E SHEET DESCRIPTION GENERAL & BID NOTESGN1.0 FOUNDATION DETAILS S6.1 TRASH ENCLOSURE FRAMING & FOUNDATION PLANS S6.2 TRASH ENCLOSURE DETAILS KITCHEN HOOD NOTES AND HVAC NOTES WASTE & GREASE PLUMBING PLANP1.2 POWER ROOF PLANE2.3 PLUMBING SITE PLANP1.0 WALL SECTIONSA7.70 UTILITY PLAN EROSION CONTROL PLAN CIVIL COVER SHEETC1.0 GRADING AND DRAINAGE PLAN CONSTRUCTION DETAILS 02 C I V I L ( F O R R E F E R E N C E ) HOOD DRAWINGS (FOR REFERENCE) ELECTRICAL COVER SHEETE0.0 CEILING DETAILSA1.32 EXISTING CONDITIONS 03 L A N D S C A P E IRRIGATION PLANL2.1 L2.2 L2.3 L3.1 L3.2 PLANTING PLAN L3.3 L3.4 PLANTING & MULCH DETAILS L3.5 PLANTING SPECIFICATIONS COVER SHEETL0.0 MATERIALS PLANL1.1 SOILS REPORT IRRIGATION NOTES L2.4 IRRIGATION DETAILS L2.5 IRRIGATION DETAILS L2.6 IRRIGATION SPECIFICATIONS PATIO FINISH & SAWCUT PLANL1.2 IRRIGATION DETAILS L2.7 IRRIGATION SPECIFICATIONS PLANTING SPECIFICATIONS REMOTE CANOPY PLAN & DETAILS. ELECTRICAL DETAILSE3.4 SITE KEYNOTE PLAN A0.31 REMOTE CANOPY PLAN & SECTIONSA0.32 PATIO RCP, ROOF PLANA0.13 KIMLEY HORN 245 E. THIRD STREET, LONG BEACH, CA 90802 PHONE: 652-549-2132 CONTACT: JULIA CHANG julia.chang@kimley-horn.com PLANNING DIVISION 20 CIVIC CENTER PLAZA SANTA ANA, CA 92701 PHONE:714-667-2700 CITY OF SANTA ANA HEALTH DEPARTMENT 1241 E. DYER RD. SUITE 120 SANTA ANA, CA 92707 PHONE: 714-433-6074 ORANGE COUNTY CHARLES MANH AND ANN MANH, AS TRUSTEES OF THE MANH FAMILY TRUST PHONE: 714-642-5573 CONTACT: CHARLIE MANH charliemanh@hotmail.com REMOTE CANOPY PLANSS3.1 L3.6 PRIVATE GENERAL NOTES 06 M E C H A N I C A L C1.1 C2.0 C3.0 C5.0 C6.0 C6.1 C7.0 C8.0 EQUIPMENT INTERIOR ELEVATIONS EQUIPMENT INTERIOR ELEVATIONS EQUIPMENT INTERIOR ELEVATIONS DEFERRED SUBMITTALS SHALL INCLUDE THE FOLLOWING: A.FIRE SPRINKLERS B.FIRE ALARM SYSTEM - SEE FIRE DEPT. NOTE #3 ON SHEET GN1.0 C.PRE-FABRICATED WOOD TRUSSES D.WALK-IN COOLER/FREEZER UNIT E.MENU BOARD & SIGNAGE F.KITCHEN HOOD PACKAGE G.DUCT FIRE EXTINGUISHING SYSTEM H.FIRE SERVICE UNDERGROUND SYSTEM 05 S T R U C T U R A L GRADING AND DRAINAGE PLAN S5.1 FRAMING DETAILSS5.2 FRAMING DETAILSS5.3 FRAMING DETAILSS5.4 FRAMING DETAILSS5.5 AGI 412 N. CEDAR BLUFF RD. SUITE 306 KNOXVILLE, TN 37923 PHONE: 800-877-7868 X3204 CONTACT: MEGAN WIGGINS mwiggins@agi.net ACCESSIBILITY DETAILS AC1 CALGREEN CHECK LISTG0.11 CRA CODE REFERENCE ANALYSIS CONDITIONS OF APPROVAL COA ACCESSIBILITY DETAILS AC2 ACCESSIBILITY DETAILS AC3 ACCESSIBILITY DETAILS AC4 CALGREEN CHECK LISTG0.12 CALGREEN CHECK LISTG0.13 CALGREEN CHECK LISTG0.14 04 A W N I N G S0.8 S1.1 FOUNDATION PLAN S0.5 S0.7 S0.4 S0.6 NOTES AND SCHEDULES TYPICAL DETAILS TYPICAL DETAILS TYPICAL DETAILS TYPICAL DETAILS GENERAL STRUCTURAL NOTES GENERAL STRUCTURAL NOTES GENERAL STRUCTURAL NOTESS0.3 S0.2 S0.1 E2.2 RISERS, SCHEDULES AND DETAILSE3.1B VOLTAGE DROP CALCULATIONSE4.4 DRIVE THRU CANOPY PLAN & DETAILS.A0.30 SP1 BRISTOL STREET CORRIDOR RAISING CANE'S RESTAURANTS, L.L.C. 6800 BISHOP RD PLANO, TX 75024 PHONE: 423-807-0008 CONTACT: SARAH HOLMES sholmes@hdgroupinc.com BUILDING DIVISION 20 CIVIC CENTER PLAZA ROSS ANNEX, M-20 SANTA ANA, CA 92701 PHONE: 714-647-5800 CITY OF SANTA ANA FIRE DEPARTMENT 1439 S BROADWAY SANTA ANA, CA 92707 PHONE: 714-567-3236 ORANGE COUNTY FIRE AUTHORITY EROSION CONTROL DETAILC3.1 DEMOLITION PLANC4.0 DIMENSIONAL CONTROL AND SITE PLANC5.1 C6.2 GRADING SECTIONS CONSTRUCTION DETAILSC8.1 DRIVE THRU CANOPY PLANE1.1 ELECTRICAL SITE PHOTOMETRICSE1.2 CONSTRUCTION TYPE OCCUPANCY FIRE SPRINKLERS HEIGHT OF BUILDING MAXIMUM STORIES MAXIMUM AREA BUILDING AREA TOTAL OCCUPANT LOAD TYPE VB ASSEMBLY (A-2) YES 40-FEET ALLOWED ONE (1) 24,000 S.F. ALLOWED 3,540 S.F. (INCLUDING CORRAL) 87 - SEE SHEET CRA BUILDING AREA (GROSS AREA) CORRAL AREA OUTDOOR PATIO BUILDING HEIGHT 405 - 272 - 24, PARCEL 1, 2, & 3 TOTAL SITE AREA BUILDING AREA IMPERVIOUS AREA LANDSCAPE AREA LAND USE ZONING APN 2,973 S.F. 290 S.F. ±1232 S.F. 23'-4" T.O. PARAPET PM DESIGN GROUP, INC. 76 E. MITCHELL DR. PHOENIX, AZ 85012 CELL PHONE: 623-432-0596 CONTACT: CHUCK BENNETT cbennett@pmdginc.com A9.10 A9.20 A9.30 A9.40 A9.50 A9.60 PROJECT SPECIFICATIONS PROJECT SPECIFICATIONS PROJECT SPECIFICATIONS PROJECT SPECIFICATIONS PROJECT SPECIFICATIONS PROJECT SPECIFICATIONS M3.3 M3.4 M3.5 M3.6 M3.7 M3.8 M3.9 M3.10 M3.11 M3.12 M3.13 M3.15 M3.16 M3.17 HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) HOOD DRAWINGS (FOR REFERENCE) 09 F O O D S E R V I C E BU I L D I N G SU B M I T T A L CODE INFORMATION PROJECT STATISTICS BUILDING CODE ANALYSIS GENERAL PROJECT NOTES: ABBREVIATIONS PROJECT TEAM & CONTACT INFORMATION VICINITY MAP DEFERRED SUBMITTALS:SEPARATE PERMITS: PM DESIGN GROUP, INC. 19401 40th AVE. WEST, SUITE 420 LYNNWOOD, WA 98036 PHONE:425-409-2496 CONTACT: JAMES YBARRA JYBARRA@PMDGINC.COM DOOR DETAILSA2.12 WINDOW DETAILSA2.23 PLAN DETAILSA8.11 PUBLIC GENERAL NOTESC2.1 CONSTRUCTION DETAILSC8.2 PLANTING SPECIFICATIONS STRUCTURALS.1 STRUCTURALS.2 STRUCTURALS.3 STRUCTURALS.4 S4.3 FOUNDATION DETAILS M3.14 M3.18 HOOD DRAWINGS (FOR REFERENCE) M3.19 HOOD DRAWINGS (FOR REFERENCE) M3.20 HOOD DRAWINGS (FOR REFERENCE) M3.21 HOOD DRAWINGS (FOR REFERENCE) M4.1 T-24 FORMS ELECTRICAL SPECIFICATIONSE4.1 Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 LL Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Professional of Record:JEFF LIEDERMAN Kitchen Issue Date: 10 76 E. MITCHELL DR. PHOENIX, AZ 85012 CONTACT: CHUCK BENNETT (623) 432-0596 CBENNETT@PMDGINC.COM Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:CB 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION ARCHITECTURE SITE PLANA0.09 BU I L D I N G SU B M I T T A L M4.2 T-24 FORMS M4.3 T-24 FORMS M4.4 T-24 FORMS M4.5 T-24 FORMS M4.6 T-24 FORMS ENERGY CODE COMPLIANCE FORMSE4.3A ENERGY CODE COMPLIANCE FORMSE4.3B WALL SECTIONSA7.80 SE Q . # SE Q . # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 99 96 97 98 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 1 1 24'-8" T.O. ENTRY TOWER NOTES THE PROJECT ADDRESS IS IN THE FEMA DESIGNATED ZONE X.4 192 ENERGY CODE COMPLIANCE FORMSE4.3C COVER SHEET001 GENERAL NOTES002 GENERAL NOTES003 DEMOLITION PLAN004 STREET IMPROVEMENT PLAN & PROFILE 005 006 007 NOTES AND DETAILS001 002 NORTH BRISTOL STREET 193 194 195 196 197 198 199 200 201 STREET IMPROVEMENT PLAN & PROFILE WATER & SEWER IMP. PLAN & PROFILE 1 2 4 A C E 3 3.70.70.6 Y 1.11 2 4 A C E 1 4 3.2 3.8 F 3 3.70.7 0.6 0.7 0.6 Y 1.1 1 1/4" = 1'-0" FRAMING PLAN 1.ALL EXTERIOR STUD DIMENSIONS ARE TO FACE OF PLYWOOD / CONC. FOOTING, TYPICAL U.N.O. - SEE A1.21 FOR SLAB DIMENSIONS & FOUNDATION PLAN 2.ALL INTERIOR STUDS DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE 3.ALL STUDS ARE TO BE 16" O.C. UNLESS NOTED OTHERWISE. 4..FINISH MATERIALS AND THICKNESS NOT SHOWN FOR CLARITY. REFER TO SHEET A3.20 FINISH FLOOR PLAN. 4. REFER TO STRUCTURAL FRAMING & SHEAR WALL PLANS AND SCHEDULES FOR DETAILS AND REQUIRED SHEATHING. 5.ALL KITCHEN AREA & WET WALLS TO HAVE DUROCK BRAND CEMENT BOARD FROM F.F. TO 8" A.F.F. W/ 1/2" PLYWOOD ABOVE. FINISH AS SCHEDULED. 6. REFER TO SHEETS FS1.10 & FS2.10 FOR BLOCKING LOCATIONS AND REQUIREMENTS OF OWNER PROVIDED MILLWORK, INSTALLED BY GENERAL CONTRACTOR. 7.REFER TO SHEET A1.30 FOR HEADER AND SOFFIT LOCATIONS AND HEIGHTS. 8. DIMENSION LEADERS ARE LOCATED AT EDGE OF SLAB, EDGE OF BRICK, VISIBLE FACE OF MASONRY, FACE OF STUDS OR CENTERLINE OF STUDS UNLESS NOTED OTHERWISE. 9.FOR ALL AIR CONDITIONING, EXHAUST & SUPPLY FANS, HVAC & REFRIGERATION EQUIPMENT CURBS; GENERAL CONTRACTOR SHALL PROVIDE & INSTALL SUITABLE BLOCKING IN WALLS & CEILINGS TO SUPPORT FIXTURES, EQUIPMENT & CANOPIES. 10. G.C. SHALL PROVIDE NECESSARY BLOCKING FOR ALL OWNER PROVIDED SIGNAGE & TABLE SUPPORTS. 11.G.C. SHALL PROVIDE NECESSARY BLOCKING FOR ALL OWNER PROVIDED SIGNAGE & TABLE SUPPORTS. GENERAL NOTES THE FOLLOWING ROOMS SHALL HAVE 1/2" DURCOCK BRAND CEMENT BOARD FROM F.F. TO 4" A.F.F. WITH 1 2" PLYWOOD ABOVE IN LIEU OF G.W.B. (ON INTERIOR SIDE) EXCEPT AT HOOD. F.R.P FINISH AS SCHEDULED: SEE SHEET A3.20. DUROCK BRAND CEMENT BOARD SHALL BE CONTINUOUS BEHIND ENTIRE LENGTH OF HOOD FROM FLOOR TO 18" ABOVE SUSPENDED CEILING AND EXTEND 18" ON EACH SIDE OF HOOD. 1. KITCHEN 2. B.O.H. 3. STORAGE PLYWOOD BACKING NOTE EXTERIOR WALL METAL STUD (16 GA.) CONSTRUCT PER UL263-U433: METAL STUDS WITH 3-1 2 " UNFACED MINERAL FIBER INSULATION WITHIN WALL CAVITY INTERIOR WALL WALL LEGEND WALL TYPES LEGEND ASSEMBLY TYPES 2x4 WOOD STUDS @ 16" O.C. UNLESS NOTED OTHERWISE 2x6 WOOD STUDS @ 16" O.C. UNLESS NOTED OTHERWISE. EXTERIOR PERIMETER WALLS TO RECEIVE CAVITY INSULATION AS INDICATED IN SPECIFICATIONS. 2x8 WOOD STUDS @ 16" O.C. UNLESS NOTED OTHERWISE HYPHENATED NUMBERS DENOTE DOUBLE-STUD WALL CONSTRUCT PER UL263-U433: 1 1/2" & 6" METAL STUDS WITH 3-1 2 " UNFACED MINERAL FIBER INSULATION WITHIN WALL CAVITY REINFORCED CONCRETE MASONRY WALL SHEAR WALL, RE: STRUCTURAL SHEATHING TYPES EXTERIOR PLYWOOD SHEATHING 1 2" CDX PLYWOOD OR OSB SHEATHING WITH 4" STRIP OF CEMENT BOARD AT BASE 1 2" CDX PLYWOOD OR OSB SHEATHING WITH 4" STRIP OF CEMENT BOARD AT BASE + 1 2" GYPSUM WALLBOARD 1 2" CDX PLYWOOD OR OSB SHEATHING WITH 4" STRIP OF CEMENT BOARD AT BASE + 1 4" TILE BACKER BOARD 1 2" FIBER CEMENT BOARD CONSTRUCT PER UL263-U433: 5 8" CEMENT BOARD SHEATHING ON BOTH SIDES 4 6 8 UL CM P P PG PG PT PT CB CB X X UL UL #-#DRIVE-THRU PAY DRIVE-THRU PICKUP KITCHEN DINING ROOM SERVING AREA CUSTOMER PICK UP RESTROOM VESTIBULE RESTROOM 1 RESTROOM 3 MECH. ROOM FREEZER COOLER EXTERIOR CORRAL KITCHEN (BOH) KITCHEN 52'-1" 24'-3"3'-10" R.O. 1'-11" 60 ' - 4 " 13 ' - 7 1 2" 52'-1" 4'-3"11'-71 2" R.O. 21'-61 2"4'-01 2" R.O. 1'-9" 25 ' - 0 " 14 ' - 0 1 2" 18'-1"23'-0" 12'-2" 55 ' - 8 " 20 ' - 0 1 2" R. O . 24 ' - 7 " 3' - 1 0 1 2" 1' - 0 " 2' - 0 1 2" R. O . 10 " 12'-2" 1' - 8 1 2" 8' - 2 1 4" 4' - 3 " 4' - 0 1 2" 14 ' - 1 3 4" 6' - 9 " 9' - 0 1 2" 7' - 0 1 4" 2' - 5 " 4' - 1 1 1 2" 3' - 3 " 2' - 1 1 " 5' - 3 1 2" 5' - 9 " 6' - 4 " 5' - 6 " 6' - 8 " 7' - 3 " 3' - 2 " 4' - 5 1 2" 3' - 1 " 4' - 5 1 2" 2' - 4 1 2" 4' - 4 " R. O . 4' - 7 3 4" 1' - 1 " 22 ' - 3 1 4" 5'-51 2"3'-61 2" 3'-4"3'-4" 1'-81 2" 9'-31 2" 1'-91 2" 2'-8"3'-2"3'-3"6'-11" 13'-4" 9'-2" 8'-53 4" 2'-91 2" 5'-9" 3'-4"4'-51 2" 2' - 5 1 2" COLUMN RE: STRUCTURAL EDGE OF CEILING SOFFIT FRAMING ABOVE. RE: RCP EDGE OF CEILING SOFFIT FRAMING ABOVE EDGE OF CEILING SOFFIT FRAMING ABOVE EDGE OF CEILING SOFFIT FRAMING ABOVE 1'-10" 9'-7" 8'-61 2" R.O. 6" 7' - 0 1 2" R . O . 13 ' - 5 1 2" R . O . 6" 3' - 2 1 2" 2' - 0 " 1' - 3 " 3'-3"13'-11" 6'-0"5'-0" 10 ' - 4 " COLUMN RE: STRUCTURAL 3' - 2 1 2" 5' - 3 " 2' - 9 1 2" 12'-21 2"3'-51 2" 11" COLUMN RE: STRUCT. 3" PVC PIPE CHASE TO RUN BETWEEN KITCHEN THROUGH WALL TO BEVERAGE CABINET (FOR KETCHUP LINES), RE: 11/A8.10 ELECTRICAL PANEL ROUGH-IN. RE: ELEC 7'-0" 3x3 STEEL POST, RE: STRUCTURAL 51 2" 6' - 4 " R. O . 1' - 4 " 7" 3' - 4 " 4" 4'-01 2" 5'-31 2" RESTROOM 2 1'-1" 3' - 0 " 12 ' - 1 " 3'-63 4"13'-0" 3' - 9 1 2" 1' - 0 " 6' - 8 " 11 ' - 3 " BLOCKING SUSPENDED FROM TRUSS BOTTOM CHORD EDGE OF CEILING SOFFIT FRAMING ABOVE EDGE OF CEILING SOFFIT FRAMING ABOVE 13'-1"13'-8"11'-0" 3' - 0 " 4P PT 6P P 4 P P 6 P PT 4 P PT 6 P PT 6 P PT 6 P PT 6PG X 6PT PT 6 PT X 6 P X 4PT 6 PT 4P PT 6X P 4PT P 4 P P 6 PT P 4P P 4PT PT 4 P P 6X CB 4 PT 4 PT 4 P PT 4 P PT 4 P PT 6P PT 6CB P 6X P 6 P P 6P PT 6X CB 6 CB P 6 P P 6 P P 4P P 4P P 6 X P 4P P 6X P 6X P 6- 4 P P 6 X UL ULUL UL 6 X P 6 PT X 6P X 5'-6" PARTIAL HEIGHT WALL 9'-61 2"3'-101 2"4'-1"6'-2"10'-0"9'-6"2'-11"5'-0" PARTIAL HEIGHT WALL 3'-5" PARTIAL HEIGHT WALL 2' - 8 1 2" 7" 7" 2' - 8 1 2" 4' - 8 " 4'-0" 4'-91 4"4'-91 4" 1' - 0 " 3' - 6 1 2" R. O . 11 2" 6" 3' - 6 1 2" R. O . 11 2" 3'-6"10'-0"3'-6" 6 PT PT 6 PT PT 6- 4 PT X 6- 6 PT X 1'-63 4" 6' - 4 1 2" 6-6PT X 6PT X 6PT X 6X P 6 X P 6" 6"11'-3" R.O. 5" 6 P P 4- 6 P X 6-4X P 3'-8" 3'-10"3'-101 2" 3' - 2 1 2" 15 ' - 4 3 4" 17'-8"22'-10" 5'-6"22'-10" 17 ' - 0 " 17 ' - 0 " 11 ' - 6 " 14 ' - 3 1 4" 4' - 2 1 2" SUPPLY SWITCH GEAR 4' - 1 0 " 4'-21 4"7"1"4'-61 4"2" 4" 3'-6" R.O. E A 0 B.2 0 C.7 Z D B B.9 41 2"8'-6" R.O. 1" 31 2" 2'-0" 1' - 5 " 1'-0" 4' - 0 " 6 X 6- 6 PT X ABOVE ABOVE 6X P 2" M I N . 64'-3" 3'-4"51 2" Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 LL Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Professional of Record:JEFF LIEDERMAN Kitchen Issue Date: 10 76 E. MITCHELL DR. PHOENIX, AZ 85012 CONTACT: CHUCK BENNETT (623) 432-0596 CBENNETT@PMDGINC.COM Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:CB 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION FRAMING PLAN A1.20 A 1 2 4 A C E 1 4 3.2 3.8 F 1 A7.80 2 A7.20 3 A7.20 2 A7.10 1 A7.20 2 A6.10 1 A6.10 1 A7.30 1 A7.70 1 A7.50 1 A6.10 3 A7.10 3 3.70.7 0.6 0.7 0.6 1 A7.10 2 A7.50 Y 1 A7.60 2 A7.60 2 A7.30 1.1 2 A7.70 1 1/4" = 1'-0" REFLECTED CEILING PLAN A.REFER TO MECHANICAL DRAWINGS FOR HVAC PLAN, SECTIONS, DUCT SIZES, SUPPLY & RETURN AIR GRILLE SIZES. B.REFER TO ELECTRICAL DRAWINGS FOR LIGHTING LAYOUT REQUIREMENTS & ADDITIONAL INFORMATION. C.REFER TO FINISH SCHEDULE AND SPECIFICATIONS FOR MATERIALS. D.ALL BLOCKING FOR FIXTURES SUSPENDED FROM CEILING IS SHOWN IN THE FRAMING PLAN. E.BACK OF HOUSE DIFFUSERS (KITCHEN) TO BE WHITE ENAMEL FINISH. FRONT OF HOUSE DIFFUSERS INSTALLED IN GYPSUM CEILINGS (FRONT COUNTER AREA, RESTROOM VESTIBULE, RESTROOMS) TO BE ALUMINUM FINISH. FRONT OF HOUSE RETURN AIR GRILLS TO BE FLAT BLACK PRE-FINISHED ALUMINUM. EXPOSED DUCTWORK TO BE UNPAINTED GALVANIZED MILL FINISH F.PROVIDE 2X4 WOOD PURLINS ON FLAT TO TIE DINING ROOM TRUSSES TOGETHER ON TOP OF BOTTOM CHORD. GC TO COORDINATE SPACING OF PURLINS WITH MECHANICAL INSTALLATION, LIGHTING LAYOUT, DECO CLOUD ELEMENTS, ETC. PAINT PURLINS TO MATCH TRUSSES (BLACK) G.CENTER LIGHTS, DIFFUSERS, FANS, ETC. BETWEEN OPEN CEILING TRUSSES. UNLESS OTHERWISE NOTED H.CENTER DIFFUSERS BETWEEN LIGHTS IN SOLID CEILING CONDITIONS I.LIGHT FIXTURES IN OPEN CEILING AREA SHALL BE BLACK FINISH J.LIGHT FIXTURES IN SOLID CEILING AREA, INCLUDING CEILING CLOUDS SHALL BE ANODIZED ALUMINUM FINISH K.ALL DIFFUSERS IN OPEN CEILING AND SOLID CEILING AREAS SHALL BE MILL FINISH. BOH LAY-IN CEILING DIFFUSERS SHALL BE WHITE L.FINISH SPRINKLER HEADS IN OPEN CEILING AREA SHALL BE BLACK FINISH M.FINISH SPRINKLER HEADS IN SOLID CEILING AREAS SHALL BE CHROME FINISH N.WOOD CEILING PLANKS SHALL BE INSTALLED AT RANDOM LENGTHS. END JOINT SPACING SHALL BE OFFSET A MINIMUM OF 12" BETWEEN ADJACENT PLANKS O.CONTRACTOR TO VERIFY LOCATION OF PENDANT FIXTURES WITH OWNER / ARCHITECT PRIOR TO INSTALLATION TO ENSURE COORDINATION WITH FURNITURE. RE: ELEC. & MECH DWGS. 2x4 LED LIGHT FIXTURE 2x2 LED LIGHT FIXTURE LINEAR LIGHT FIXTURE DINING CEILING FAN MOUNT B. O FAN 9'-0" A.F.F. RECESSED CAN LIGHT RECESSED SQUARE LIGHT WALL WASH LIGHT PENDANT LIGHT - CEILING LEVEL ALIGN BOTTOM OF PENDANT TO B. O. TRUSS FACE SPUNEC FIXTURE MOUT 7'-5' AFF TO ℄ OF FIXTURE WALL SCONCE INTERIOR OUTDOOR PENDANT LIGHT. B. O. PENDANT 9'-0" A.F.F. HVAC RETURN AIR HVAC SUPPLY DIFFUSER HVAC DIFFUSER FESTOON LIGHTING TO ATTACH TO CABLE: PART #HF2-EY90QC ORDER FROM LIGHTING SUPPLIER, CABLE TO ATTACH TO EYELETS SPACED 5' MAX. BOTTOM OF SWAG 8'-10 EXTENDED SCONCES SPOT LIGHT ACCESS HATCHPATIO CEILING FAN MOUNT B. O. FAN 9'-6" A.F.F. EXIT LIGHT X'-X" CLG. HT.CEILING HEIGHT KEY NOTE ROOM NAME DETAIL OR SECTION DESIGNATION FINISH TAG 00 A0.00 ROOM NAME 00 XXX-X EXTERIOR WALL SCONCE 1.UNDERSIDE METAL DECK REMAIN NATURAL GALVANIZED FINISH 2.CEILING ACCESS a.CEILING ACCESS DOOR. SEE 10/A8.30 b.CEILING ACCESS PANEL WOOD FINISH TO MATCH & ALIGN WITH ADJACENT CEILING. SEE 9/A8.30 3.ROOF ACCESS HATCH & LADDER. RE: 11/A8.30 4.WINDOW SIGN 5.SHELVING UNITS SUSPENDED FROM CEILING. BLOCKING REQUIRED - SEE SHEETS FS1.10 & FS2.10 6.LIGHT MOUNTED UNDER CABINET TO UPPER SHELF 7.OPEN TRELLIS STRUCTURE. RE: STRUCT. DWG'S. 8.FRONT COUNTER CEILING CLOUD SUPPLIED BY OWNER VIA MILLWORK VENDER, SCHEME "B" FINISH W-3 9.DINING ROOM CEILING CLOUD, SCHEME 'B' FINISH W-2, ALIGN WITH CENTER OF ACCENT TILE 10.MUSIC SPEAKER SHELF PER MILLWORK. PROVIDE BLOCKING IN WALL, REFER TO FOOD SERVICE ELEVATIONS SHEET FS3.40 11.LINE OF GYP. BULKHEAD. REFER TO INTERIOR ELEVS. FOR FINISH. 12.MENU BOARD CEILING MOUNTED. BLOCKING REQ'D. 13.CEILING MOUNTED DRIVE THRU MONITORS, BLOCKING REQ'D. 14.AWNING BY OTHERS (AGI). G.C. SHALL COORD. WITH STRUCTURAL DWGS, RE: AWNING DWGS 15.EXTERIOR SPEAKERS, RE: EXT. ELEVS. & ELEC. DWGS. 16.STAINLESS STEEL HOOD, UNPAINTED, RE: MECH. DWGS. 17.2x6 WOOD C.J. OR 6"x20 GA. METAL JOIST @ 16" O.C 18.2'x4' ACOUSTIC CEILING PANEL SPACED 8' O.C. PARALLEL TO TRUSSES AND 4' O.C. PERPENDICULAR TO TRUSSES. PANELS FASTENED TO B.O. ROOF DECK 19.PROVIDE BLCKG. BETWEEN TRUSSES TO SURFACE MOUNT A1E FIXTURE. B.O. BLCKG. 14 1/4" ABOVE B.O. TRUSS 20.18" MIN. 1-HR FIRE RATED ACOUSTICAL CEILING TILE SYSTEM AROUND HOOD AREA 21.TRUSS, DECKING AT DINING AREA PAINT P-2 (TYP. U.N.O) 22.AIR CURTAIN (MARS LPN2-42) AT SERVICE DOOR 603. REFER TO MECH. DWG'S.. 23.AIR CURTAIN AT DRIVE-THRU WINDOWS RE: SPECS. SECT. 08.56.19. MECHANICAL DWGS 24.COOLER LIGHTING BY COOLER MANUFACTURER. 25.5/8" W.R. GYP. BD. CEILING - ATTACH TO BOTTOM OF ROOF TRUSS CHORD. 26.MISTER PUMP HANGER. 27.EXHAUST FAN. RE: MECH. DWG'S. # 2'x2' ACOUSTICAL CEILING TILE (WASHABLE). SEE DET. 1,2,5,6,7,15/A1.32 *NOTE: REFER TO CEILING KEYNOTES FOR ADDITIONAL FINISH OPTIONS CYPRESS WOOD CEILING PLANKS (SUPPLIED AND INSTALLED BY G.C.) GYP. BD CEILING - PAINTED. SEE DET. 8,9,10/A1.3.2 2'x4' TECTUM ACOUSTIC CEILING PANEL PAINT P-2 ACT W-2 ACP 8'-9" 18'-0" 8' - 8 " 9'-7" AFF CLOUD 9 20'-0" 6'-0"4'-0"2'-0"4'-0"2'-0"2'-0"4'-0"2'-0"4'-0" 1 A1.31 DRIVE-THRU PAY DRIVE-THRU PICKUP KITCHEN DINING ROOM SERVING AREA RESTROOM VESTIBULE RESTROOM 1 RESTROOM 3 MECH. ROOM FREEZER COOLER KITCHEN (BOH) KITCHEN 2' - 3 " 1' - 1 0 " 2' - 0 " 2' - 0 " 2' - 0 " 4' - 2 " 3'-0" EQEQ 4' - 0 " 3'-0"3'-0"3'-0"EQ 3'-5"EQ3'-0"3'-0"EQEQ2'-8"EQ 1' - 5 " SUPPLY 1 CUSTOMER PICK UP 2a W-2 10 15 15 15 2a 9'-0" AFF CEILING 10'-0" AFF CEILING 9'-6" AFF CEILING 9'-6" AFF CEILING 9'-6" AFF CEILING 9'-4" AFF HEADER 12'-2" AFF CEILING 9'-4" AFF HEADER 9'-4" AFF HEADER 10'-0" AFF CEILING ACT 6 ACT ACT ACT HOOD UNPAINTED STAINLESS STEEL RE: MECHANICAL HOOD UNPAINTED STAINLESS STEEL RE: MECHANICAL P-4 P-3 P-3 P-3 P-3 10'-11 1/2" AFF CEILING P-1 10'-8" AFF CEILING P-2 2a P-1 P-2 P-4 13 12 5 4'-5" 9'-0" AFF CEILING 9'-0" AFF CEILING 3 P-2 8 2' - 3 " 2' - 3 " EQ EQ 2a P-3 P-3 1' - 5 " 12'-2" AFF CEILING 5 2 A8.30 2 A8.30 8'-0" AFF HEADER 9'-6" AFF HEADER 10 12 ' - 3 " 4' - 6 " P-11B ACCENT TRUSS 4 A8.30 9'-6" AFF CEILING 5 19 10'-0" 3' - 0 " 5' - 0 " P-2 18 TYP. 6' - 0 " EQ EQ EQ EQ 3'-4"2'-3"2'-3"3'-4" EQ EQ EQ EQ 1'-3" EQ EQ 24 TYP. 22 12'-11" ℄ OF WINDOW 3' - 6 " 23 16 16 4 4 P-4 RESTROOM 2 17 17 17 9'-0" AFF CEILING 17 TYP. 21 TYP. 20 20 20 20 20 14 23 2 A0.30 1 1 1 MT-1 W-2 26 11 5' - 6 " 9' - 3 " 3' - 3 " 7'-6" AFF HEADER 3'-111 2"8'-2"8'-2"8'-2" EQ 5'-0" EQ 5'-0" 6' - 2 " 5' - 0 " 5' - 0 " EQ EQ.EQ. EQ EQ EQ EQ 7' - 0 " 7' - 0 " EQ EQ 2' - 5 1 2" 2'-1" MANAGER'S OFFICE EQEQ 8 A8.30 5' - 0 " 5 W-2 14 4'-0" 9' - 0 " ℄ O F W I N D O W 9'-6" ℄ OF WINDOW 4' - 0 " W-2 12-2" AFF CEILING 12-2" AFF CEILING EQ EQ EQ 12'-2"" AFF SOFFIT 1'-7" EQ 5'-0"5'-0"EQ EQ EQ 10'-0" AFF HEADER SWITCH GEAR P-3 P-3 4'-0"3'-9" E A 0 B.2 0 C.7 Z 2 A6.10 D B 1 A7.40 B.9 EQ EQ 8' - 0 " EQ 8' - 0 " 9' - 5 " EXTERIOR CORRAL RCP MATERIAL LEGENDSYMBOL LEGEND REFLECTED CEILING PLAN LEGEND REFLECTED CEILING PLAN KEY NOTES GENERAL NOTES 7 25 25 +12" A.F.F +12'-3" A.F.F +12'-3" A.F.F 11'-7" 7 EQ 1 A8.30 EQ 27 3 A7.50 1 A0.13 14 Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 LL Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Professional of Record:JEFF LIEDERMAN Kitchen Issue Date: 10 76 E. MITCHELL DR. PHOENIX, AZ 85012 CONTACT: CHUCK BENNETT (623) 432-0596 CBENNETT@PMDGINC.COM Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:CB 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION REFLECTED CEILING PLAN A1.30 33 3 A AA A 120v D/T WINDOW RETURN 1' - 6 " 120v 3'-10" 120v 4' - 0 " 120v 10"8" 612"1'-4" FIXEDOPEN 1 ELEVATION (Drive-Thru Beverage & Ice Area) 3/8"= 1'-0" FS3.1 2 ELEVATION (Cookline & D/T Pickup) 3/8"= 1'-0" FS3.1 3 ELEV 3/8"= 1'-0" FS3.1 5 ELEVATION (Prep) 3/8"= 1'-0" FS3.14ELEV/Prep 3/8"= 1'-0" FS3.1 6 ELEV/Prep 3/8"= 1'-0" FS3.1 7 ELEV/Pay WDW 3/8"= 1'-0" FS3.1 8 ELEV/Pay WDW 3/8"= 1'-0" FS3.1 9 ELEV/Pay WDW 3/8"= 1'-0" FS3.1 10 ELEVATION (Electrical Panels) 3/8"= 1'-0" FS3.1 11 ELEVATION (Cookline Support Line) 3/8"= 1'-0" FS3.1 12 ELEVATION (Toast Line) 3/8"= 1'-0" FS3.1 13 ELEVATION (Bread Rack, Hand Sink, Lockers) 3/8"= 1'-0" FS3.1 1' - 6 " FW-A 4' - 0 " 9" HW 1'-0" 6" 4' - 0 " 6" 4'-9" 5' - 6 " 5' - 0 " 4" PVC CHASE FOR COKE BUNDLE, STUB ABOVE CEILING, ELBOW AT WALL PENETRATION ON DRIVE-THRU SIDE. 4' - 0 " 2'-4" 2' - 0 " 1'-10"1'-2" 2' - 0 " 3'-9" 2'-4" 1'-0" 6' - 4 " 6'-9" 2'-6" 4" PVC CHASE FOR ICE CONDENSERS, STUB ABOVE CEILING, ELBOW AT WALL PENETRATION ON DRIVE-THRU SIDE 1'-10"1'-8" 6"8" KDS MONITOR DIMENSION FROM CORNER AT WALL, TO CLEAR OPENING IN THE HOOD CANOPY. CONTROL PANEL WILL EXTEND BEYOND TO THE LEFT 17'-10" 2'-1" 4' - 6 " STUB 1.5" E.C. ABOVE CEILING, TO SHARED BACK OF HOUSE AREA, DOWN TO MUD RING. (PROVIDE PULL STRING) 5' - 6 " 9'-33 4"COMM. LINES 3,4 & KP-2; TO OFFICE; PHONE LINE 3 BUMP BAR IN WINDOW RETURN HOOD ELECTRICAL CONTROL AND ANSUL CABINETS 6"MIN. CLEARANCE EDGE OF COOKING SURFACE TO EDGE OF HOOD CANOPY (VERIFY CODE) GAS LINE TO BE PER DRAWINGS AND ANY CODES 4" CLEAR OPEN AREA OF CANOPY CONTROL/ANSUL/ELECTRIAL PANEL FOR HOOD. ALL HOOD PLACEMENT DIMENSIONS ARE TO OPEN PART OF CANOPY (VERIFY WHICH END(S) THIS UNIT IS INSTALLED ON)6" STUB 1.5" E.C. ABOVE CEILING, THEN DOWN TO MUD RING. (PROVIDE PULL STRING)3/4" GALVANIZED GREASE DISPOSAL PIPING STUBBED TO ACTUAL OR FUTURE PLANNED LOCATION. NEED TO LEAVE CLEARANCE FOR 4" COVER OVER PIPE. (VERIFY WITH OWNER) 7'-11"6" 1' - 6 " 6" KDS MONITOR GAS LINE 1' - 0 " 3'-3"3'-7" 9"9" 2' - 0 " 1' - 6 " 3'-3"3'-3" DARPRO LINE 2'-6" 6' - 0 " 1' - 6 " 3'-6" 9"8" STUB JBOX & 3 4" E.C. IN DRYWALL WINDOW RETURN, ABOVE CEILING FOR MICROPHONE 4' - 6 " 4' - 6 " 1'-3" 4' - 6 " DUPLEX RECEPTACLE, INSIDE 8X8 BOX, TO FACE LENGTH OF 8X8 BOX. 8x8 J-BOX, WITH (1) 2" RIGID CONDUIT FOR WIRELESS BASE (HME) (STUB ABOVE CEILING) 5' - 0 " STUB 1-1/2" E.C. ABOVE CEILING AND DOWN TO TWO MUD RINGS. (PROVIDE PULL STRING(S)). 6' - 0 " 1'-2"6" 7'-1" 2' - 3 " 1'-11"4" DRIVE-THRU MONITOR (SHARED) STUB 1-1/2" E.C. ABOVE CEILING, DOWN TO TWO MUD RINGS FOR DATA TO EACH REGISTER AND MONITOR ON WALL STUB 3 4" E.C. ABOVE CEILING OUT TO DRIVE-THRU SPEAKER POST FOR WIRING AND LOOP DETECTOR (PROVIDE PULL STRING) OUTLET FOR WIRELESS HEADSET CHARGING 7' - 6 " 1'-8" 1' - 6 " DRIVE-THRU CANOPY BACKLIT SWITCH (S) STUB 1 1/2" E.C. ABOVE CEILING OUT TO CANOPY AMENITIES (PROVIDE PULL STRING) 6" 2'-9" 2' - 0 " CEILING DUPLEX RECEPTACLE AT CEILING MONITOR POST SUPPORT BLOCKING NEEDED FOR MOUNTING POST 5'-6" HOOD 6" 7' - 0 " 4"1'-4" 3'-9" 1'-6" 7' - 0 " 8' - 6 " GREASE DISPOSAL REMOTE CONTROL PANEL UNIT AND HARNESS BY OTHERS. 30 FT. LATERAL DISTANCE FROM DISPOSAL TANK 6' - 6 " KDS STUB 1.5" E.C. ABOVE CEILING, THEN DOWN TO MUD RING. (PROVIDE PULL STRING) 6' - 0 " 1' - 6 " 4' - 2 " 6"5" 6"7" 1' - 6 " 1'-0" 4" 6" 1' - 6 " 1'-3" Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 LL Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Professional of Record:JEFF LIEDERMAN Kitchen Issue Date: 10 76 E. MITCHELL DR. PHOENIX, AZ 85012 CONTACT: CHUCK BENNETT (623) 432-0596 CBENNETT@PMDGINC.COM Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:CB 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION EQUIPMENT ELEVATIONS FS3.20 2 3 A 3' - 6 " 120v 2'-4" HW CW 1' - 6 " 120v FW-A 4' - 0 " 3'-5" 8" 120v 3' - 6 " 5' - 6 " 1' - 1 0 " TW O D R A W E R L A T E R A L FI L E W I T H S T O R A G E CA B I N E T A B O V E SHELVING SHELVING 6' - 9 " 1'-7" 120v 10 ' - 0 " PHONE LINES (1 & 2) 4' - 0 " 1' - 6 " MONI T O R MONI T O R PRINTER SAFE DESK 6' - 1 0 " 10"3'-1"1'-7" 8"4" 1'-0"8"8" PHONE LINES (3 & 4) 120v(IG) 120v(IG) DUPLEX NOT ISOLATED GROUND CAT-5 120v(IG) OV E R H E A D S H E L V I N G U N I T 1" CONDUIT ABOVE CEILING 4' - 6 " 9' - 6 " 4'-8" 3'-9" TYCO BOX TRANSMITTER 6" 8" 9' - 6 " 120v 120v 120v 6" 120v 3' - 8 " 8' - 6 " 8' - 1 0 " LIGHT LIGHT 120v SINGLE RECEPTACLE AND DEDICATED CIRCUIT FOR SAFE 1'-8" (3) DOUBLE GANG J-BOX(S) BOXES FOR MUSIC ATTENUATOR(S) 21 ELEVATION (Prep) 3/8"= 1'-0" FS3.1 22 ELEVATION (Office) 3/8"= 1'-0" FS3.1 23 ELEVATION (Office) 3/8"= 1'-0" FS3.1 24 ELEVATION (Office) 3/8"= 1'-0" FS3.1 25 ELEVATION (Office) 3/8"= 1'-0" FS3.1 26 ELEVATION (Cane's Gear) 3/8"= 1'-0" FS3.1 HW 4' - 0 " 6" HOSE BIB, HOT WATER, FOR CHEMICAL SYSTEM DISPENSER HW CW 2'-6" 3' - 0 " HW CW 5'-2"10" 1' - 6 " 14 . 5 " CL E A R 1' - 0 " 4' - 0 " 1' - 6 " 1' - 6 " 2' - 0 " 3" PVC CHASE BETWEEN WALL FROM UNDER COUNTER THRU WALL TO END OF CABINET ON OTHER SIDE. (KETCHUP LINES) 17 ELEV (Mop) 3/8"= 1'-0" FS3.1 18 ELEV (Mop) 3/8"= 1'-0" FS3.1 20 ELEVATION (3-Compartment Sink) 3/8"= 1'-0" FS3.1 TWO 8"X8"X4" PLYWOOD BOXES WRAPPED IN FRP, STRAPPED/MOUNTED TO WALL FOR COKE BUNDLED SYRUP LINES. INSTALL LASCO FITTINGS INC. #9851040 SCH80C SOLID STYLE SLIP 4" FLANGE 6' - 8 " 1'-6" 9' - 3 " 1'-0"6" 12 0 v 2'-0" NOTE: PUMPS TO BE MOUNTED ON WALL AND NOT ON RACK. FW-A FW-A 19 ELEVATION (Soda Bib Racks) 3/8"= 1'-0" FS3.1 9' - 0 " 7' - 1 0 " 120v 1' - 6 " 120v120v FW-A 2'-2" 1'-6"8" 15 ELEVATION (Pickup WDW POP & 3rd Board) 3/8"= 1'-0" FS3.1 7' - 0 " 7' - 6 " 16 ELEVATION (Cooler Door, Dry Storage, & Rear Door) 3/8"= 1'-0" FS3.1 7' - 6 " J-BOXES FOR THERMOSTATS 5' - 6 " J-BOXES FOR GFCI OVERRIDES FOR EQUIP UNDER THE HOOD (CONFIRM NUMBER NEEDED) 4' - 1 0 " 3' - 6 " 6" 9" STUB 3 4" E.C. ABOVE CEILING S/S COVER PLATE, SWITCH BANK FOR BOH 3-WAY & PILOT LIGHT INTERIOR SIGN(S) SWITCH. DECORA S/S COVER PLATE, SWITCH BANK FOR LOBBY FAN(S) SHARED CONTROLLER, PATIO FAN(S) SHARED CONTROLLER, AND LOBBY NIGHT LIGHT CONTROLLER VOLUME CONTROLS DOUBLE GANG BOX FOR LOBBY ATTENUATOR S/S DECORA COVER PLATE 14 ELEVATION (Office Wall & Dining Board) 3/8"= 1'-0" FS3.1 6' - 6 " 1'-512" HOLD ALL CUBBIES 1' - 6 " 10" BUMP BAR 5'-4" 4' - 0 " BUMP BAR 1' - 6 " STUB 1.5" E.C. ABOVE CEILING, THEN DOWN TO MUD RING. (PROVIDE PULL STRING) 6' - 0 " 2'-3"2'-1" 6" 4' - 6 " D/T WINDOW RETURN 612" 1' - 6 " 1'-9" 6' - 6 " 6" POWER AND DATA ON THIS SOFFIT VERTICAL SURFACE NEAR END OF PIPE SHELVING UNIT., RUN POWER CORD AND DATA LINE OVER AND DOWN PIPE TO END PANEL OF WOODEN BOX, TO KDS 4"1'-4" BUMP BAR AT FRONT EDGE OF SHELF CEILING DUPLEX RECEPTACLE AT CEILING MONITOR POST SUPPORT. BLOCKING NEEDED FOR MOUNTING POST. CEILING DATA JBOX AT CEILING MONITOR POST SUPPORT KITCHEN 3-WAY LIGHT SWITCH SINGLE GANG BOX WITH CONDUIT CHASE STUBBED TO CEILING ABOVE, FOR SECURITY KEYPAD WIRINGJ-BOX FOR DOOR BELL ON THE EXTERIOR SIDE OF THIS WALL ANSUL PULL STATION (SHOWN SURFACE MOUNTED, CAN BE IN THE WALL) J-BOX ON THIS SIDE OF WALL FROM EXTERIOR DOOR BELL BELOW, FOR SURFACE MOUNTED BELL, THEN CONDUIT CONTINUED TO CEILING ABOVE J-BOX ABOVE CEILING, TO POWER TRANSFORMER TO DETEX PANIC BAR ALARM AND FOR TRANSFORMER TO DOOR BELL 5' - 0 " 3' - 0 " 4' - 0 " 3' - 6 " METAL FLAP DOOR, AT BOTH VISION WINDOWS, HINGED AT TOP 6" 6" 1' - 7 " PROVIDE BLOCKING ABOVE DOOR FOR OPTIONAL FLY FAN, MARS MODEL LPN248-1UA-OB. VERIFY INSTALLATION OF FAN WITH OWNER CONDUIT FROM DEXTEX PANIC BAR ALARM TO DOOR CONTACT LOCATION, 6" FROM EDGE OF DOOR J-BOX FOR DOOR BELL ON THE EXTERIOR SIDE OF THIS WALL 6" MUD RING FOR NETWORK ROUTER NETWORK ROUNTER 9' - 0 " CW FW-A FW-B 1'-6"1'-0"4'-0" Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 LL Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Professional of Record:JEFF LIEDERMAN Kitchen Issue Date: 10 76 E. MITCHELL DR. PHOENIX, AZ 85012 CONTACT: CHUCK BENNETT (623) 432-0596 CBENNETT@PMDGINC.COM Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:CB 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION EQUIPMENT ELEVATIONS FS3.30 3 3 3 A 1355 E Cooley Dr, Ste C Colton, CA 92324 P (909) 824-7311 Terracon.com January 28, 2025 Raising Cane's Restaurants, LLC 800 Bishop Road, Suite 210 Plano, TX 75024-4274 Attn: Ms. Kristen Roberts E: KRoberts@raisingcanes.com P: (972) 769-3348 Re: Plan Review Letter RC# 1032 - Santa Ana 1303 N Bristol St Santa Ana, California Terracon Project Number CB235017 Dear Ms. Roberts: At the request of Sara Emami from PM Design, on your behalf, Terracon has prepared this letter to document our review of the structural plans prepared for the proposed project. References: 1.“Raising Cane’s Restaurant #C1032”, 1303 N. Bristol St., Santa Ana, CA 92706, P6E- HV Scheme B, Sheets S0.1, S0.4, S0.5, S0.8, S1.1, S3.1 S4.1, S4.2, S4.3, S6.1, and S6.2, prepared by Wright Structural Engineers, dated July 1, 2024, building resubmittal date of January 20, 2025. 2.“Geotechnical Engineering Report”, Raising Cane’s Restaurant (RC-1032) – Santa Ana, Terracon Project Number CB235017, prepared by Terracon, dated March 23, 2023. It is our opinion that the geotechnical recommendations presented in our geotechnical engineering report (Reference 2) appear to have generally been incorporated into the referenced plan sheets cited above (Reference 1). The referenced documents have been reviewed for Geotechnical aspects only. We make no representation regarding accuracy of dimensions, quantities, measurement, calculations or any portion of the design not related to the geotechnical aspects of this project. Plan Review Letter RC# 1032 - Santa Ana | Santa Ana, California January 28, 2025 | Terracon Project Number CB235017 Facilities |Environmental |Geotechnical | Materials 2 If you have any inquiries or comments regarding this letter, please do not hesitate to contact the undersigned at your convenience. Sincerely, Terracon Consultants, Inc. Phillip Penrose, P.E. Project Engineer 1 2 4 1 4 3.2 3.8 3 3.70.7 0.6 0.7 0.6 1.1 DRIVE-THRU PAY DRIVE-THRU PICKUP DINING ROOM SERVING AREA CUSTOMER PICK UP RESTROOM VESTIBULE RESTROOM 1 RESTROOM 3 MECH. ROOM FREEZER COOLER EXTERIOR CORRAL KITCHEN (BOH) KITCHEN RESTROOM 2 SUPPLY SWITCH GEAR OFFICE UTILITY CABINET. 24 X 1 8 X 8 . 6 2 B O X UTILITY CABINET. § U.L. LISTED RECESSED ROUND LED FIXTURE AND LED LIGHT. 9" § U. L . L I S T E D R E C E S S E D R O U N D L E D FI X T U R E A N D L E D L I G H T . E A 0 B.2 0 C.7 Z D B B.9 MECHANICAL SYMBOL SCHEDULE2 KEYNOTES3 A C E F Y Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE M1.1 HVAC FLOOR PLAN 1 HVAC FLOOR PLAN 1/4"= 1'-0" A A A A 4 MOUNTED EXHAUST FAN N.T.S. CURB MOUNTING FOR ROOF- ROOFTOP UNIT 5 SUPPORT AND DRAIN DETAIL N.T.S. 3 ROUND DUCT BRANCH RUNOUT CONNECTION DETAIL N.T.S. 2 ROOFTOP UNIT DETAIL N.T.S. 8 OUTDOOR AIR REQUIREMENTS - 2022 CMC 7 AIR BALANCE SCHEDULE N.T.S. SPIRAL DUCT SUPPORT6 FOR RR EXHAUST TO RTU-110N.T.S. LOW VOLTAGE THERMOSTAT WIRING DIAGRAM 9 AIR CURTAIN SCHEDULE 1 MECHANICAL EQUIPMENT SCHEDULES Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE M2.1 HVAC SCHEDULES AND DETAILS A 1 WALL CANOPY KITCHEN HOOD1 DETAIL N.T.S. 3 HOOD EXHAUST FAN / MAKE-UP AIR UNIT DETAILS N.T.S. 2 WALL CANOPY KITCHEN HOOD2 DETAIL N.T.S. 14' 6"NOM./14' 6.00"OD. 16'-6.00" OVERALL LENGTH 54" 12" UTILITY CABINET. 24 X 1 8 X 8 . 6 2 B O X 12" UTILITY CABINET. 2" 24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"12"12" 18" 24 3/4" 9" 12" 24" 49 1/2" 9" 12" 24" 49 1/2" 9" 12" 24" 49 1/2" 9" 12" 24" LIGHTING FOR ACPSP JOB # 6950327 - HOOD #1 INPUT: 120V AC, 1 PHASE, 50/60HZ, 3.5 WATTS PER LIGHT. TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH, WIRE PER HOOD ELECTRICAL CONTROL PANEL SCHEMATIC. TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH, WIRE BLACK AND WHITE WIRE TO A 120VAC SERVICE. END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY. 1" LAYER OF INSULATION FACTORY INSTALLED IN INTERNAL BACK STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 3" § 40 15/16" 12" Ø14" 90 1/16"43" 12" Ø14" U.L. LISTED RECESSED ROUND LED FIXTURE AND LED LIGHT. 1" 1.00" WIDE INSULATED BACKSPLASH 122.00" HIGH X 234.00" LONG. NOTE: ADDITIONAL HANGING ANGLES PROVIDED FOR HOODS 12' AND LONGER. 5' 6"NOM./5' 6.00"OD. 54" 2" 21"21"12"12" 18" 33" 9" 12" 28" LIGHTING FOR ACPSP JOB # 6950327 - HOOD #2 INPUT: 120V AC, 1 PHASE, 50/60HZ, 3.5 WATTS PER LIGHT. TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH, WIRE PER HOOD ELECTRICAL CONTROL PANEL SCHEMATIC. TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH, WIRE BLACK AND WHITE WIRE TO A 120VAC SERVICE. END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY. 1" LAYER OF INSULATION FACTORY INSTALLED IN INTERNAL BACK STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 3" § 33"33" 12" Ø10" U.L. LISTED RECESSED ROUND LED FIXTURE AND LED LIGHT. 1" 1.00" WIDE INSULATED BACKSPLASH 122.00" HIGH X 66.00" LONG. 1" LAYER OF INSULATION FACTORY INSTALLED IN 3" INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. §EXHAUST RISER. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. ATTACHING PLATES. SUPPLY RISER WITH VOLUME DAMPER. 6" 2 3/4" 14" LED. 18" 1.00" WIDE INSULATED BACKSPLASH 122.00" HIGH X 234.00" LONG. FIELD WRAPPER 8.00" HIGH (SEE HOOD OPTIONS TABLE). 1" LAYER OF INSULATION FACTORY INSTALLED ON TOP OF HOOD. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 23" 23" LEFT AND RIGHT QUARTER END PANELS. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54"1" 55" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 1" LAYER OF INSULATION FACTORY INSTALLED IN 3" INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. §EXHAUST RISER. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. ATTACHING PLATES. SUPPLY RISER WITH VOLUME DAMPER. 6" 2 3/4" 14" LED. 18" 1.00" WIDE INSULATED BACKSPLASH 122.00" HIGH X 66.00" LONG. FIELD WRAPPER 8.00" HIGH (SEE HOOD OPTIONS TABLE). 1" LAYER OF INSULATION FACTORY INSTALLED ON TOP OF HOOD. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 23" 23" LEFT AND RIGHT QUARTER END PANELS. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54"1" 55" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. M3.1 KITCHEN HOOD DETAILS AND HVAC SPECS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A Louisiana Office REGION 27 PHONE: (985) 781 - 4107 EMAIL: reg27@captiveaire.com FOR QUESTIONS, CALL THE 1 2 KH-1 KH-2 5424 ND-2-PSP-F 5424 ND-2-PSP-F CAPTIVEAIRE CAPTIVEAIRE 14' 6" 5' 6" 600 DEG 450 DEG I I HEAVY MEDIUM 225 175 3262 962 4" 4" 4" 14" 14" 10" 1631 1631 962 1526 1526 1764 -0.636" -0.636" -0.504" 2544 770 430 SS WHERE EXPOSED 430 SS WHERE EXPOSED ALONE ALONE ALONE ALONE HOOD NO TAG MODEL MANUFACTURER LENGTH MAX COOKING TEMP TYPE APPLIANCE DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM RISER(S) WIDTH LENG HEIGHT DIA CFM VEL SP TOTAL SUPPLY CFM HOOD CONSTRUCTION HOOD CONFIG END TO END ROW 1 2 KH-1 KH-2 CAPTRATE SOLO FILTER CAPTRATE SOLO FILTER 10 4 20" 20" 16" 16" 85% SEE FILTER SPEC 85% SEE FILTER SPEC 9 4 RECESSED ROUND RECESSED ROUND NO NO LEFT RIGHT 12"x54"x24" 12"x54"x24" TANK FS TANK FS 4.0 4.0 SC-311110MA 1 LIGHT 1 FAN YES YES 1627 LBS 446 LBS HOOD NO TAG FILTER(S) TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS LIGHT(S) QTY TYPE WIRE GUARD UTILITY CABINET(S) LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WEIGHT 1 2 KH-1 KH-2 FIELD WRAPPER 8.00" HIGH FRONT, LEFT, RIGHT. BACKSPLASH 122.00" HIGH X 234.00" LONG X 1.00" WIDE INSULATED 430 SS VERTICAL. RIGHT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS. LEFT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS. INSULATION FOR TOP OF HOOD. STRUCTURAL FRONT PANEL. INSULATION FOR BACK OF HOOD. RISER SENSOR INSTALL 6IN PLEN. FULL DIMENSION HANGING BRACKET - FRONT. FIELD WRAPPER 8.00" HIGH FRONT, LEFT, RIGHT. BACKSPLASH 122.00" HIGH X 66.00" LONG X 1.00" WIDE INSULATED 430 SS VERTICAL. RIGHT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS. LEFT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS. INSULATION FOR TOP OF HOOD. INSULATION FOR BACK OF HOOD. RISER SENSOR INSTALL 6IN PLEN. HOOD NO TAG OPTION 1 2 KH-1 KH-2 Front Front 198" 66" 18" 18" 6" 6" MUA MUA MUA MUA MUA 12" 12" 12" 12" 12" 24" 24" 24" 24" 28" 636 636 636 636 770 0.181" 0.181" 0.181" 0.181" 0.178" HOOD NO TAG POS LENGTH WIDTH HEIGHT TYPE RISER(S) WIDTH LENG DIA CFM SP 1500500 FLOW RATE (CFM) 1000 0.00 0 0.50 PR E S S U R E D R O P ( i n . H 2 0 ) PRESSURE DROP VS. FLOW RATE RRSPECIFICATION: CAPTRATE GREASE-STOP SOLO FILTER A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, THE CAPTRATE GREASE-STOP SOLO FILTER IS A SINGLE-STAGE FILTER FEATURING LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND COMPONENTS WHEN ASSEMBLED. 2-INCH DEEP HOOD CHANNEL(S). TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO FR A C T I O N A L E F F I C I E N C Y ( % ) 0 0.1 20 40 1.0 PARTICLE DIAMETER (UM) 10.0 EFFICIENCY VS. PARTICLE DIAMETER 60 80 100 THE CAPTRATE GREASE-STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. TE A NSF ACCORDANCE No. 96 NFPA WITH BUILT IN SLI DTE RO CH B N RAN I,OR M . YR OR LAIGNTSB AT CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. NFPA #96. NSF STANDARD #2. UL STANDARD #1046. INT. MECH. CODE (IMC). ULC-S649. 1.00 1.50 2.00 2.50 3.00 3.50 MANUFACTURER APPROVED FOR USE IN SOLID FUEL APPLICATIONS AS A SPARK ARRESTER. GREASE DUCT & CHIMNEY SPECIFICATIONS: PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW" ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW" IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW" DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATION GUIDE. PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING MODEL "DW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" PER 12", HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12". DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN HORIZONTAL RUNS. IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. § CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF LISTED, PRE-FABRICATED ROUND GREASE EXHAUST DUCT TO REDUCE STATIC PRESSURE IN THE SYSTEM, MINIMIZE INSTALLATION AND INSPECTION TIMES, AND ENSURE DUCT IS LIQUID TIGHT CUSTOMER APPROVAL TO MANUFACTURE: ___' - ___" VERIFY CEILING HEIGHT HVAC DISTRIBUTION NOTE HIGH VELOCITY DIFFUSERS OR HVAC RETURNS SHOULD NOT BE PLACED WITHIN TEN (10) FEET OF THE EXHAUST HOOD. PERFORATED DIFFUSERS ARE RECOMMENDED. PATENT NUMBERS AC-PSP WALL (CANADA) - CA PATENT 2820509. AC-PSP (UNITED STATES) - US PATENT 7963830 B2. AC-PSP ISLAND (CANADA) - CA PATENT 2520330. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m MARVIN BORDELON FOR QUESTIONS, CALL FAX: (919) 747-5637, REG27@CAPTIVEAIRE.COM REGION 27 59040 Amber Street Ste B, Slidell, LA 70461 PHONE: (985) 781-4107 ALL SPECIFIERS & CONTRACTORS SHOULD CONTACT REG27 CAPTIVE AIRE OFFICE TO COORDINATE PROPER INTEGRATION OF KITCHEN VENTILATION SYSTEM FOR PROJECT NATIONAL ACCOUNT M3.3 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A 14' 6"NOM./14' 6.00"OD. 16'-6.00" OVERALL LENGTH 54" 12" UTILITY CABINET. 24 X 1 8 X 8 . 6 2 B O X 12" UTILITY CABINET. 2" 24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"12"12" 18" 24 3/4" 9" 12" 24" 49 1/2" 9" 12" 24" 49 1/2" 9" 12" 24" 49 1/2" 9" 12" 24" LIGHTING FOR ACPSP JOB # 6950327 - HOOD #1 INPUT: 120V AC, 1 PHASE, 50/60HZ, 3.5 WATTS PER LIGHT. TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH, WIRE PER HOOD ELECTRICAL CONTROL PANEL SCHEMATIC. TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH, WIRE BLACK AND WHITE WIRE TO A 120VAC SERVICE. END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY. 1" LAYER OF INSULATION FACTORY INSTALLED IN INTERNAL BACK STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 3" § 40 15/16" 12" Ø14" 90 1/16"43" 12" Ø14" U.L. LISTED RECESSED ROUND LED FIXTURE AND LED LIGHT. 1" 1.00" WIDE INSULATED BACKSPLASH 122.00" HIGH X 234.00" LONG. NOTE: ADDITIONAL HANGING ANGLES PROVIDED FOR HOODS 12' AND LONGER. 5' 6"NOM./5' 6.00"OD. 54" 2" 21"21"12"12" 18" 33" 9" 12" 28" LIGHTING FOR ACPSP JOB # 6950327 - HOOD #2 INPUT: 120V AC, 1 PHASE, 50/60HZ, 3.5 WATTS PER LIGHT. TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH, WIRE PER HOOD ELECTRICAL CONTROL PANEL SCHEMATIC. TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH, WIRE BLACK AND WHITE WIRE TO A 120VAC SERVICE. END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY. 1" LAYER OF INSULATION FACTORY INSTALLED IN INTERNAL BACK STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 3" § 33"33" 12" Ø10" U.L. LISTED RECESSED ROUND LED FIXTURE AND LED LIGHT. 1" 1.00" WIDE INSULATED BACKSPLASH 122.00" HIGH X 66.00" LONG. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. FULL LENGTH HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). FULL LENGTH HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. SUPPLY PLENUM HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR SUPPLY PLENUM). SUPPLY PLENUM HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR PSP HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) HOODS #SURFACE *CLEARANCE 1 TOP 0" FRONT 0" BACK 0" LEFT 0" RIGHT 0" 2 TOP 0" FRONT 0" BACK 0" LEFT 18" RIGHT 18" - *0" CLEARANCE TO COMBUSTIBLES CONFORMS TO UL710 STANDARD. - HOOD MOUNTED UTILITY CABINETS REQUIRE 36" SERVICE CLEARANCE. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.4 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A 1" LAYER OF INSULATION FACTORY INSTALLED IN 3" INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. §EXHAUST RISER. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. ATTACHING PLATES. SUPPLY RISER WITH VOLUME DAMPER. 6" 2 3/4" 14" LED. 18" 1.00" WIDE INSULATED BACKSPLASH 122.00" HIGH X 234.00" LONG. FIELD WRAPPER 8.00" HIGH (SEE HOOD OPTIONS TABLE). 1" LAYER OF INSULATION FACTORY INSTALLED ON TOP OF HOOD. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 23" 23" LEFT AND RIGHT QUARTER END PANELS. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54"1" 55" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 1" LAYER OF INSULATION FACTORY INSTALLED IN 3" INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. §EXHAUST RISER. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. ATTACHING PLATES. SUPPLY RISER WITH VOLUME DAMPER. 6" 2 3/4" 14" LED. 18" 1.00" WIDE INSULATED BACKSPLASH 122.00" HIGH X 66.00" LONG. FIELD WRAPPER 8.00" HIGH (SEE HOOD OPTIONS TABLE). 1" LAYER OF INSULATION FACTORY INSTALLED ON TOP OF HOOD. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 23" 23" LEFT AND RIGHT QUARTER END PANELS. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54"1" 55" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 1" COMBUSTIBLE WALL LENGTH - STAINLESS STEEL BACKSPLASH INSULATED WITH 1" THICK DUCTBOARD WITH FOIL BACKING. - INSULATED BACKSPLASH REQUIRES APPLIANCES WITH CLEARANCE TO COMBUSTIBLES REQUIREMENTS TO BE MOUNTED A MINIMUM OF 6" OFF OF THE COMBUSTIBLE WALL. -HOOD REAR INSULATION MUST BE UTILIZED WITH INSULATED. BACKSPLASH, UNLESS INSULATED BACKSPLASH EXTENDS TO TOP OF HOOD. SLIDE TOP FLANGE BEHIND LOWER REAR EDGE OF HOOD UNLESS LOCAL JURISDICTION REQUIRES EXTENDED BACKSPLASH FLANGES LOCATED AT TOP AND BOTTOM HEIGHT SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.5 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A 1 2 TANK FS PCU TANK 4.0 4.0/4.0/4.0 4.0/4.0/4.0 20 60 36 62 28 FIRE CABINET LEFT FIRE CABINET RIGHT PCU UTILITY CABINET LEFT, HOOD 1 RIGHT, HOOD 1 N/A FIRE SYSTEM NO TAG TYPE SIZE MAX FP DESIGN FP INSTALLATION SYSTEM LOCATION ON HOOD 1 SC ELECTRICAL 2.500 CAPTIVEAIRE SYSTEMS FIRE SYSTEM NO TAG TYPE SIZE SUPPLIED BY 1 2 0 - 0 - TANK FIRE SUPPRESSION POST-DISCHARGE PROCEDURE UTILITY CABINET LABEL SHEET. 0 - 0 - TANK FIRE SUPPRESSION MAINTENANCE GUIDE UTILITY CABINET LABEL SHEET. 0 - 0 - 12-F28021-32144-OT-360 DUCT FIRE THERMOSTAT WITH 12 FOOT WIRE LEADS. NO, CLOSE ON TEMP RISE AT 360°F. (A0034310). 0 - 0 - 4429K153 1/2" MALE NPT TO 1/2" FEMALE NPT ELBOW, BRASS. 0 - 0 - 4429K422 1/2" X 1/4" BRASS REDUCING BUSHING. 0 - 0 - 79525 1/2" 90 PRO-PRESS ELBOW WITH 1/2” NPT FEMALE CONNECTION, VIEGA. 0 - 0 - 79580 1/2" X 1/2" PRO-PRESS TEE X 1/2” NPT FEMALE CONNECTION, VIEGA. 0 - 0 - 87-120045-001 HOSE, SECONDARY ACTUATOR HOSE, 7.5" BRAIDED STAINLESS STEEL, TANK FIRE SUPPRESSION. 0 - 0 - 87-300001-001 TANK - PRESSURIZED TANK USED FOR TANK FIRE SUPPRESSION. 0 - 0 - 87-300030-001 PRIMARY ACTUATOR KIT (PAK) - ACTUATOR AND RELEASE SOLENOID ASSEMBLY, ONE NEEDED PER FIRE SYSTEM, SUPERVISED, TANK FIRE SUPPRESSION. 0 - 0 - 87-300152-001 HARDWARE, SVA BOLTS, TANK FIRE SUPPRESSION. 0 - 0 - 98694A115 HARDWARE, DATANKLOCK LOCKING BRACKET SQUARE NUTS 5/16" ZINC, TANK FIRE SUPPRESSION. 0 - 0 - A0034332 JUNCTION BOX FOR MANUAL PULL STATION. 1.5" DEEP BACK BOX, RED COLOR. 0 - 0 - A31484 1/4" NPT SCHRADER VALVE AND CAP, JB INDUSTRIES. 1/4" FLARE X 1/4" MPT HALF UNION. USED ON TANK SERVICE PORT. 0 - 0 - DATANKLOCK DISCHARGE ADAPTER TANK LOCKING PLATE FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY CABINETS, TANK FIRE SUPPRESSION. 0 - 0 - SLPCON-03FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 2' GAP. KIT CONTAINS 5 FEET OF BLACK MG WIRE, 5 FEET OF TAN MG WIRE, 3 FEET OF FLEXIBLE CONDUIT, AND TWO 7/8" CONNECTORS. 0 - 0 - SLPCON-10FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 9' GAP OR BACK TO BACK HOODS. KIT CONTAINS 12 FEET OF BLACK MG WIRE, 12 FEET OF TAN MG WIRE, 10 FEET OF FLEXIBLE CONDUIT, AND TWO 7/8" CONNECTORS. 0 - 0 - SLPCON-30FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO CONNECT THE SUPERVISED LOOP BETWEEN HOODS WITH UPTO 29' GAP. KIT CONTAINS 32 FEET OF BLACK MG WIRE, 32 FEET OF TAN MG WIRE, 30 FEET OF FLEXIBLE CONDUIT, AND TWO 7/8" CONNECTORS. 0 - 0 - TANK STRAP TANK STRAP - USED FOR TANK FIRE SUPPRESSION. 0 - 0 - TFS-UCTANKBRACKET TANK BRACKET FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY CABINETS, TANK FIRE SUPPRESSION. 0 - 0 - WK-283952-000 DISCHARGE ADAPTER, TANK FIRE SUPPRESSION. 34 - 34 - A0034331 24VDC SINGLE ACTION MANUAL ACTUATION DEVICE (PUSH/PULL STATION) WITH PROTECTIVE COVER, ONE (1) NORMALLY OPEN CONTACT. RED COLOR. 0 - 0 - 87-120042-001 SECONDARY ACTUATOR VALVE (SVA) - SINGLE ACTUATOR, REQUIRES PRIMARY RELEASE ACTUATOR, TANK FIRE SUPPRESSION. 0 - 0 - 87-120045-001 HOSE, SECONDARY ACTUATOR HOSE, 7.5" BRAIDED STAINLESS STEEL, TANK FIRE SUPPRESSION. 0 - 0 - 87-300001-001 TANK - PRESSURIZED TANK USED FOR TANK FIRE SUPPRESSION. 0 - 0 - 87-300030-001 PRIMARY ACTUATOR KIT (PAK) - ACTUATOR AND RELEASE SOLENOID ASSEMBLY, ONE NEEDED PER FIRE SYSTEM, SUPERVISED, TANK FIRE SUPPRESSION. 0 - 0 - 87-300033-001 DIN CONNECTOR, CANFIELD PART #5J560-201-EU0A, TANK FIRE SUPPRESSION, SUBMINATURE SOLENOID CONNECTION (CED VENDOR 30377). 0 - 0 - 87-300152-001 HARDWARE, SVA BOLTS, TANK FIRE SUPPRESSION. 0 - 0 - TANK STRAP TANK STRAP - USED FOR TANK FIRE SUPPRESSION. 0 - 0 - TFS-UCTANKBRACKET TANK BRACKET FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY CABINETS, TANK FIRE SUPPRESSION. 0 - 0 - WK-283952-000 DISCHARGE ADAPTER, TANK FIRE SUPPRESSION. 1 1 3 4 3 3 4 2 4 2 16 8 2 3 4 1 1 1 12 4 4 2 2 2 3 1 1 6 9 3 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 FIRE SYSTEM NO TAG KEY NUMBER - PART DESCRIPTION QTY BY FACTORY QTY BY DIST SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.6 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. 12" Ø14" 12" Ø14" HOOD FRONT HOOD BACK HOOD # 1 (KH-1) JOB # 6950327 FS # 1 MODEL: ND-2-PSP-F SIZE: 54"x24" LENGTH: 14' 6" TA N K O V E R L A P P I N G P R O T E C T I O N - 3 0 HI G H P R O X I M I T Y 16 2 . 0 0 " L X 2 4 . 0 0 " D DUCT S 360 OL-F DUCT S 360 OL-F OL-F OL-F 24.00" 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F NOZZLE HEIGHT 35-50" FROM COOKING SURFACE. (45.25") 18.00"27.60"27.60"27.60"27.60"27.60"18.00" SLPCON-03FT KIT SLPCON-30FT KIT - SYSTEM REQUIRES A MINIMUM OF 7 FT OF EQUIVALENT PIPE LENGTH BETWEEN TANK AND NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES. EACH 90 DEGREE ELBOW ADDS 1.3 FT OFEQUIVALENT LENGTH. SEE MANUAL FOR DETAILS - SYSTEM REQUIRES A MINIMUM OF 7 FT OF EQUIVALENT PIPE LENGTH BETWEEN TANK AND NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES. EACH 90 DEGREE ELBOW ADDS 1.3 FT OF EQUIVALENT LENGTH. SEE MANUAL FOR DETAILS 7 1 2 5 - SYSTEM REQUIRES A MINIMUM OF 7 FT OF EQUIVALENT PIPE LENGTH BETWEEN TANK AND NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES. EACH 90 DEGREE ELBOW ADDS 1.3 FT OFEQUIVALENT LENGTH. SEE MANUAL FOR DETAILS - SYSTEM REQUIRES A MINIMUM OF 7 FT OF EQUIVALENT PIPE LENGTH BETWEEN TANK AND NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES. EACH 90 DEGREE ELBOW ADDS 1.3 FT OF EQUIVALENT LENGTH. SEE MANUAL FOR DETAILS 1 631 1 3 6 2 5 FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. 12" Ø10" HOOD FRONT HOOD BACK HOOD # 2 (KH-2) JOB # 6950327 FS # 1 MODEL: ND-2-PSP-F SIZE: 54"x24" LENGTH: 5' 6" TA N K O V E R L A P P I N G P R O T E C T I O N - 3 6 HI G H P R O X I M I T Y 54 . 0 0 " L X 2 4 . 0 0 " D DUCT S 360 OL-F OL-F 24.00" 21.50" OL-F 21.50" OL-F NOZZLE HEIGHT 35-50" FROM COOKING SURFACE. (45.25") 18.00"30.00"18.00" SLPCON-10FT KIT PL E N U M ALTERNATE FIELD-CONNECTION POINTPL E N U M PL E N U M NOTES - FIELD PIPE DROPS AS SHOWN PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS. - FIELD INSTALLED DROP: FACTORY WILL PROVIDE QTY 2 60IN LONG PIECES OF CHROME PLATED PIPING SHIPPED LOOSE TO BE FIELD-INSTALLED. - SHIP LOOSE DROP: FACTORY WILL PROVIDE THE EXACT CHROME PIPE LENGTH NEEDED SHIPPED LOOSE TO BE FIELD-INSTALLED. - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - OVERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN OBSTRUCTION. - IF APPLICABLE, EXTENDED PRE-PIPED DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS PRE-ENGINEERED FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS. - OL-F NOZZLE PART NUMBER REPLACES 3070-3/8H-10-SS JOB #: 6950327. JOB NAME: RAISING CANE'S 1032. SYSTEM SIZE: TANK-SP-1 WITH REMOTE TANK-SP-3 DESIGN FP: 62. MAXIMUM FP: 80. HOOD # 1 14' 6.00" LONG x 54" WIDE x 24" HIGH. RISER # 1 SIZE: 14" DIA. RISER # 2 SIZE: 14" DIA. HOOD # 1 METAL BLOW-OFF CAPS INCLUDED. HOOD # 2 5' 6.00" LONG x 54" WIDE x 24" HIGH. RISER # 1 SIZE: 10" DIA. HOOD # 2 METAL BLOW-OFF CAPS INCLUDED. - HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITIONAL DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK CONTAINS ANY HORIZONTAL RUNS OVER 25 FT IN LENGTH. - MEDIUM TO LIGHT-DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE ANY ADDITIONAL DOWNSTREAM DETECTION. AGENT DISTRIBUTION PIPING LIMITATIONS PIPE SECTION MAX PIPE LENGTH (FT) MAX SUPPLY LINE TO FIRST OVERLAPPING NOZZLE 42 OVERLAPPING NOZZLE APPLIANCE BRANCH 10 DEDICATED NOZZLE APPLIANCE BRANCH 10 PRESSURE SUPERVISION SWITCH. PRIMARY ACTUATOR RELEASE. 4 GALLON TANK. 7 6 5 4 2 1 PRIMARY HOSE ASSEMBLY. SECONDARY ACTUATOR RELEASE.3 SECONDARY HOSE ASSEMBLY. REMOTE MANUAL ACTUATION DEVICE. 1" LAYER OF INSULATION FACTORY INSTALLED IN 3" INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. §EXHAUST RISER. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. ATTACHING PLATES. SUPPLY RISER WITH VOLUME DAMPER. 6" 2 3/4" 14" LED. 18" 1.00" WIDE INSULATED BACKSPLASH 122.00" HIGH X 234.00" LONG. FIELD WRAPPER 8.00" HIGH (SEE HOOD OPTIONS TABLE). 1" LAYER OF INSULATION FACTORY INSTALLED ON TOP OF HOOD. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 23" 23" LEFT AND RIGHT QUARTER END PANELS. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54"1" 55" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 21 1/2" 1" LAYER OF INSULATION FACTORY INSTALLED IN 3" INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. §EXHAUST RISER. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. ATTACHING PLATES. SUPPLY RISER WITH VOLUME DAMPER. 6" 2 3/4" 14" LED. 18" 1.00" WIDE INSULATED BACKSPLASH 122.00" HIGH X 66.00" LONG. FIELD WRAPPER 8.00" HIGH (SEE HOOD OPTIONS TABLE). 1" LAYER OF INSULATION FACTORY INSTALLED ON TOP OF HOOD. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 23" 23" LEFT AND RIGHT QUARTER END PANELS. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54"1" 55" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 21 1/2" TANK FIRE SUPPRESSION PUSH 4-5/8" 3-3/16" 5-3/8" 7-3/8" INCLUDES: FIELD INSTALLATION AND HOOKUP DURING NORMAL BUSINESS HOURS BY CERTIFIED INSTALLERS ONLY IN THE LOCATION NOTED ABOVE, TWO SITE VISITS ONLY (ONE VISIT TO SET PULL STATION & SYSTEM HOOKUP AND ONE VISIT FOR ONE TEST; ADDITIONAL VISITS WILL RESULT IN ADDITIONAL CHARGES), ONE MECHANICAL OR ELECTRICAL GAS VALVE PER SYSTEM AT A MAXIMUM SIZE OF 2", PERMIT, AND SYSTEM TEST. EXCLUDES: UNION LABOR & PREVAILING WAGE (LABOR & WAGES WILL BE ADDED IF APPLICABLE), GAS VALVE INSTALLATION, ELECTRICAL HOOKUP AND CONNECTIONS, HANGING OF FIRE CABINET, SHUNT TRIP, HANDHELD EXTINGUISHER(S), ON-SITE RE-PIPING DUE TO EQUIPMENT LAYOUT CHANGES.SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.7 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A 26" 34"Ø 42" 18" MINIMUM CLEARANCE TO COMBUSTIBLES. 18" MINIMUM CLEARANCE TO COMBUSTIBLES. 18" MINIMUM CLEARANCE TO COMBUSTIBLES. 18" MINIMUM CLEARANCE TO COMBUSTIBLES. 46 1/8" 5 1/4" 28" FIRE SENSOR. NOZZLE PART# . 1/8" GASKET. 28" 1/8" GASKET. 28" 1/8" GASKET. 35" FIRE SENSOR. 25 1/4" 56 3/8" 30 1/2" 42 3/8" 49 1/4" 2" DRAIN EXTENSION.56 3/16"2" 28 3/16" 119 5/16" 86 5/8" 205 7/8" SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.8 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A 1 PCU-1 1 USBI24DD-RM CAPTIVEAIRE 4224 2.100 1321 ODP,PREMIUM 7.500 5.5620 3 208 22.3 1400 FPM 2197 35.8 FAN UNIT NO TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA DISCHARGE VELOCITY WEIGHT (LBS)SONES 2 MAU-1 A2-20D-MPU 1 2 2.5 5 208-230 208-230 3 PHASE 3 PHASE 60 HZ 60 HZ 11.2 AMPS 21.4 AMPS 9.07 AMPS 17.4 AMPS 20 AMPS 30 AMPS 14 AWG 10 AWG 14 14 FAN UNIT NO TAG FAN UNIT MODEL #CONDENSER NO TONNAGE VOLTAGE PHASE FREQUENCY MCA RLA MAX FUSE SIZE MIN WIRE SIZE SEER 2 MAU-1 1 A2-20D-MPU 20MF-2-MOD A2 2700 3314 0.500 1251 ODP,PREMIUM 2.000 1.1050 3 208 6.1 7.7A 15A 1348 13.7 FAN UNIT NO TAG QTY FAN UNIT MODEL #BLOWER HOUSING MIN CFM DESIGN CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA MCA MOCP WEIGHT (LBS)SONES 2 MAU-1 DX 3314 90.0°F 69.0°F 74.2°F 63.8°F ------------56.8 MBH 54.8 MBH 2.0 MBH --------------------------- FAN UNIT NO TAG COIL TYPE DESIGN CFM COOLING ENTERING DB TEMP ENTERING WB TEMP LEAVING DB TEMP LEAVING WB TEMP ENTERING FLUID TEMP LEAVING FLUID TEMP FLUID FLOW RATE PERCENT GLYCOL TOTAL CAPACITY SENSIBLE CAPACITY LATENT CAPACITY HEATING ENTERING DB TEMP LEAVING DB TEMP ENTERING FLUID TEMP LEAVING FLUID TEMP FLUID FLOW RATE PERCENT GLYCOL STEAM PRESSURE TOTAL CAPACITY SENSIBLE CAPACITY 1 2 PCU-1 MAU-1 YES FAN UNIT NO TAG EXHAUST GREASE CUP GRAVITY DAMPER WALL MOUNT SUPPLY SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 2 3 4 # 2 MAU-1 PCU-1 20 LBS 76 LBS 76 LBS 125 LBS RAIL CURB CURB RAIL RAIL RAIL RAIL RAIL 6.000"W X 21.000"L X 20.000"H. 31.000"W X 121.000"L X 20.000"H INSULATED. 31.000"W X 121.000"L X 20.000"H INSULATED. 6.000"W X 45.250"L X 20.000"H. 6.000"W X 45.250"L X 20.000"H. 6.000"W X 45.250"L X 20.000"H. 6.000"W X 45.250"L X 20.000"H. 6.000"W X 45.250"L X 20.000"H. NO ON FAN TAG WEIGHT ITEM SIZE SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.9 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A FAN UNIT NO TAG QTY DESCRIPTION 1 PCU-1 1 UTILITY SET GREASE CUP 1 BI24 - 24" DISCHARGE EXTENSION 1 BI - DISCHARGE ORIENTATION VERTICAL UPPER LEFT - CW INLET SIDE 1 BI24 - INLET CONNECTION STANDARD 24" FLANGED GREASE DUCT 1 POLLUTION CONTROL UNIT WITH PREFILTER, DUAL HIGH EFFICIENCY, AND ODOR CONTROL FILTERS WITH INSTALLED ELECTRIC DETECTION SYSTEM. PRESET TO ACTIVATE AT 360° F. SIZE 4 1 PCU-SIZE 4 USBI-24 DD 1 BLUE RUBBER VIBRATION ISOLATORS FOR BI UTILITY SETS (SET OF 8) 1 2 YEAR PARTS WARRANTY 2 MAU-1 1 SIZE 2 UNTEMPERED COMMERCIAL DOWN DISCHARGE FOR DIRECT DRIVE AHUS 1 INSULATED BLOWER SECTION SIZE 1-2 COMMERCIAL 1 MIXING BOX SHELL FOR SIZE 2 MOD PACKAGE UNIT CONDENSER SUPPORT 1 7.5 TON 2 CIRCUIT (2.5/5) MODULAR PACKAGED COOLING OPTION FOR SIZE 2 MUA (2,700 TO 4,500 CFM), 208V/230V, 3 PHASE. COOLING THERMOSTAT OR PROGRAMMABLE STAT REQUIRED FOR PROPER OPERATION 1 MOD PACKAGE UNIT AC CONTROLS FOR UNTEMPERED FANS 1 SHIP CONDENSERS LOOSE - TWO CONDENSERS, THREE PHASE - CONDENSER DISCONNECTS SHIPPED LOOSE. ALL PIPING AND WIRING BETWEEN INDOOR AND OUTDOOR UNITS BY OTHERS 1 SEPARATE 120V WIRING PACKAGE (REQUIRED AND USED ONLY FOR DCV OR PREWIRE WITH VFD) - THREE PHASE ONLY 1 2 YEAR PARTS WARRANTY SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.10 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A 13 1/4" 25 3/4" 28 3/16" 43 15/16" 41 3/4" 26" 34"Ø42" 18" MINIMUM CLEARANCE TO COMBUSTIBLES. 18" MINIMUM CLEARANCE TO COMBUSTIBLES. 18" MINIMUM CLEARANCE TO COMBUSTIBLES. 18" MINIMUM CLEARANCE TO COMBUSTIBLES. 46 1/8" 5 1/4" 28" 1/8" GASKET. 28" 1/8" GASKET. 28" 1/8" GASKET. 35" SERVICE DISCONNECT SWITCH. UL 1978 BOLTED DOOR CONSTRUCTION. 25 1/4" 56 3/8" 30 1/2" 42 3/8" 49 1/4" 2" DRAIN EXTENSION.56 3/16"2" 28 3/16" 119 5/16" 86 5/8" 205 7/8" 12"9"9"9" 18" MINIMUM CLEARANCE TO COMBUSTIBLES. 18" MINIMUM CLEARANCE TO COMBUSTIBLES. 44" 42 5/8" 46 1/2" EXTENSION. 45 1/4"45 1/4" 6" 61 3/16" 92 5/8" 150 7/8" 202" 20.000" HIGH EQUIPMENT RAIL. 14 3/4" L ETSDI R PCU OPTIONS: - PCU ADVANCED FILTER MONITORING SYSTEM- SIZE 4. - INLET 41.719" BY 43.963" RECTANGULAR TO 34" ROUND TRANSITION FOR SIZE 4. 26" LONG. - UL-1978/UL-8782 CONSTRUCTION FOR PCUS-BOLTED DOOR DESIGN- SIZE 4. - CLIMATE CONTROLLED UTILITY CABINET FOR FIRE SYSTEM INSTALLATION. FOR USE WITH FIRE SYSTEMS. FAN OPTIONS: - UTILITY SET GREASE CUP - BI24 - 24" DISCHARGE EXTENSION. - BI - DISCHARGE ORIENTATION VERTICAL UPPER LEFT - CW INLET SIDE. - BI24 - INLET CONNECTION STANDARD 24" FLANGED GREASE DUCT. - POLLUTION CONTROL UNIT WITH PREFILTER, DUAL HIGH EFFICIENCY, AND ODOR CONTROL FILTERS WITH INSTALLED ELECTRIC DETECTION SYSTEM. PRESET TO ACTIVATE AT 360° F. SIZE 4 - PCU-SIZE 4 USBI-24 DD - BLUE RUBBER VIBRATION ISOLATORS FOR BI UTILITY SETS (SET OF 8) - 2 YEAR PARTS WARRANTY 1 2 3 4 CAPTRATE SOLO HIGH EFFICIENCY HIGH EFFICIENCY OC 100% CARBON MERV 8 MERV 15 MERV 15 N/A 10 10 10 10 20X25X2 20X25X4 20X25X4 20X25X4 0.345 0.228 0.228 0.704 1.505 PCU FILTER SPECIFICATIONS DESIGN CFM - 4224 MODULE FILTER TYPE FILTER EFFICIENCY QTY SIZE SP(CLEAN) (in WC) SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.11 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A 121" FLEX CONDUIT FOR FIELD WIRING. BLOWER DISCHARGE. 16" 10" 18 3/4" 8 5/8" LIFTING LUG. AIRFLOW. BLOWER/MOTOR ACCESS DOOR 24" SERVICE CLEARANCE REQ. SERVICE DISCONNECT SWITCH. AIRFLOW. COOLING COIL MODULE. 1" MPT CONNECTION FOR SS PITCHED DRAIN PAN. COIL ACCESS DOOR.AIRFLOW. AIRFLOW. 49 3/8" 16 1/4" 31" 20" EQUIPMENT CURB. 40 1/8" 36 3/4" 42 1/8" 47 3/4" 49 3/8" 82 1/4" 42 1/8" 178" MIN. 20" MINIMUM STRAIGHT DUCT PER AMCA* FAN #2 A2-20D-MPU - SUPPLY FAN (MAU-1) 1. SUPPLY UNIT WITH 20" MIXED FLOW DIRECT DRIVE FAN IN SIZE #2 HOUSING. 2. INTAKE HOOD WITH EZ FILTERS. 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT. 4. DOWN DISCHARGE CONSTRUCTION FOR SIZE 2 UNTEMPERED DIRECT DRIVE AHUS. 5. INSULATED BLOWER HOUSING SIZES 1-2 COMMERCIAL MODULAR. 6. SUPPORT SHELL FOR SIZE 2 MODULAR PACKAGE UNIT. INCLUDES CONTROL VESTIBULE. INCLUDES CONDENSER SUPPORTS. DOES NOT INCLUDE RETURN AIR OR INLET AIR DAMPER. 7. 7.5 TON, DUAL CIRCUIT (2.5/5) MODULAR PACKAGED COOLING OPTION FOR SIZE 2 MODULAR PACKAGED UNIT. INCLUDES CONDENSER, DX COIL, FILTER/DRYER KIT, THERMAL EXPANSION VALVE. (2,700 TO 4,500 CFM) WHEN ORDERED WITH OPPOSITE AIRFLOW CONDENSERS ACCESS AND COIL PIPING WILL REMAIN IN STANDARD POSITION. DRAIN AND SLEDS WILL MOVE TO THE OPPOSITE SIDE. ANY OTHER CHANGE WILL REQUIRE CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. COIL = 3EZ1101C. 8. CONTROL PACKAGE FOR MOD PACKAGE UNIT COOLING ONLY UNIT. INCLUDES AIRFLOW PROVING SWITCH, RTULINK-ACHP BOARD AND TERMINAL BLOCKS. 9. SHIP CONDENSERS LOOSE. THE REFRIGERATION LINES WILL NEED TO BE STUBBED OUT 12 INCHES. THE SUCTION LINES NEEDS TO BE INSULATED INSIDE THE COIL MODULE. ROTARY DISCONNECT SHOULD NOT BE INSTALLED ON THE POST, BLANK POST SHOULD BE USED IN PLACE. ALL PIPING AND WIRING BETWEEN INDOOR AND OUTDOOR UNITS BY OTHERS. 10. SEPARATE 120VAC WIRING PACKAGE FOR MAKE-UP AIR UNITS. OPTION MUST BE SELECTED WHEN MOUNTING VFD IN PREWIRE PANEL OR WITH DCV PACKAGE. PROVIDES SEPARATE 120VAC INPUT TO SUPPLY FAN. THIS 120V SIGNAL MUST BE RUN BY ELECTRICIAN FROM DCV TO MUA SWITCH. 11. HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER/MPU SECTION). 12. 2 YEAR PARTS WARRANTY. *NOTE: SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. SUGGESTED STRAIGHT DUCT SIZE IS 20" x 20". **NOTE: CONDENSERS SHIPPED LOOSE FOR REMOTE MOUNTING. ALL WIRING AND PIPING BETWEEN INDOOR AND OUTDOOR UNIT TO BE COMPLETED BY OTHERS. L ETSDI R ROOF OPENING 2" SMALLER THAN CURB DIMENSION. 6" 6" 3" FLANGE. 20 GAUGE CONSTRUCTION. STEEL 20" 31"121" OPTIONS: - FULL BOTTOM CORNERS. CURB. 6" 24" SERVICE. 24" SERVICE. 24" SERVICE. 24" SERVICE. 18"18" 48" CLEARANCE REQUIRED ABOVE CONDENSERS. (NOTE: **CONDENSERS SHOWN HERE ARE NOT DRAWN AT SCALE). 6"12" 12" 12" 12" 18" 12" MIN. 5 13/16" CLEAN OUT. TYPICAL DRAIN TRAP INSTALL NO UNIONS. RECOMMENDED COOLING COIL DRAIN TRAP CONFIGURATION. NOTES: 1) 1" DIAMETER PVC PIPE ONLY. 2) USE ONLY LOW PROFILE COUPLINGS. 3) ADD CLEAN OUT AS SHOWN. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m 21"21" 22 15 16" SUCTION LINE LIQUID LINE 6" 20" 22 15 16" 6" M3.12 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A SW-01 BK BK MT-01 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 GR BK GR Label Description Location MT-01 Supply motor [2] SW-01 Main disconnect switch [2] Component Identification 23 BK BK BK Installed Options DENOTES INTERNAL WIRING DENOTES FIELD WIRING NOTES 7 8RD(DCV SF1)WH (DCV N1) DCV/VFD Wiring (MAY NOT BE NEEDED DEPENDING ON OPTIONS) IF DCV IS NOT PRESENT, RD AND WH WIRES FROM SEPARATE 120VAC SOURCE RTUlink-ACHPTS-06 [16] DDP-106-313 AFSPS-01 [17] SW-02 CONDENSER 1 CONDENSER 2 GR 3 PHASE 208/230 BL GR BL 9 5 COIL 13 23 CONT2 11 21 COMP1 10 6 CONT1 COIL 13 11 23 21 T3 T2 T1 BL 21 BL BL BL SW-02 RD RD RD 11 7 3 12 8 4 208/230 3 PHASE T3 COMP2 T2 T1 RD RD RD BL Condenser Wiring [18]40 Amp Rotary DisconnectSW-02 [15] Cooling Transformer(40va)TR-05 [4] BK WH 1 TR-05115 BL 24 YW N RCR1 BK RD WH WH YW RC YW RC OR Y2 GY Y1 MOCP = 10 AMPS FOR CONTROL WIRING DROP FOR DISCONNECT CONNECTION !ATTENTION ELECTRICIAN! CONNECT POWER TO THE DROP 1 2 5 6 3 4 BL [16-17]Overflow Switch SW-06 TS-06 + COOL STAGE ON TIMER = 2 MIN. COOL STAGE OFF TIMER = 2 MIN. COOL HYSTERESIS = 1 MIN. C SN-01 BK GY OR +C SN-02 BK [20]Outside Air SensorSN-01 [20]Discharge Air SensorSN-02 STANDARD PARAMETERS Y1 Y2 Outside Temp Discharge Temp RD RD RC PS-01 R1 BK NO C NC C BL R SW-06 FL R1 Alarm 1 AirflowBL BL YW RD BK CONDENSER(S) TO BE FIELD WIRED CONTROL MODE = COOL STAGE BASED ON = OUTSIDE ACTIVATE BASED ON = OUTSIDE MODE CHANGE TIME = 5 MIN. SINGLE STAGE COOLING STAGE 1 COOLING SETPOINT = 85°F TWO STAGES COOLING STAGE 1 COOLING SETPOINT = 85°F STAGE 2 COOLING SETPOINT = 95°F THREE STAGES COOLING STAGE 1 COOLING SETPOINT = 85°F STAGE 2 COOLING SETPOINT = 90°F STAGE 3 COOLING SETPOINT = 95°F IS FACTORY SUPPLIED Y1 Y2 WIRE COLOR YW - YELLOW GY - GRAY PR - PURPLE GR - GREENBL-BLUE BR - BROWN OR - ORANGE BK-BLACK WH - WHITE PK - PINK RD - RED SUPPLY 2.0HP-208V-3P-6.1FLA MOTOR INFO ELECTRICAL INFORMATION MOTOR CIRCUIT MCA: 7.7A CONTROL CIRCUIT MCA: 1.0A MOTOR CIRCUIT MOP: 15A CONTROL CIRCUIT MOP: 15A COND1 MCA = 21.4A COND1 MOP = 30A COND2 MCA = 11.2A COND2 MOP = 20A DRAWING NUMBER JOB MODELSHIP DATEA6950327-2 6950327 - Raising Cane's 1032 7/2/2025 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Label Description Location MT-01 Fan Motor [3] SW-01 Main disconnect switch [3] Component Identification 23 Installed Options RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES FIELD WIRING DENOTES INTERNAL WIRING NOTES SW-01 BK BK MT-01 GR BK GR BK BK BK 5 6 3 4 1 2 GR EXHAUST 7.5HP-208V-3P-22.3FLA VFD PART: ESV552N02TXB571 MOTOR INFO ELECTRICAL INFORMATION MOTOR/CTRL MCA: 27.9A MOTOR/CTRL MOP: 50A DRAWING NUMBER JOB MODELSHIP DATEEXH6950327-1 6950327 - Raising Cane's 1032 7/2/2025 24 25 23 22 21 20 XX TERMINAL IN PANEL INTERNAL WIRING FIELD WIRING NOTES 19 18 17 16 15 14 13 12 7 9 11 10 8 6 5 4 3 DRAWING NUMBER 2 1 JOB NAME JOB NUMBER DATE COMPONENT IDENTIFICATION DescriptionLabel Location PCU#2-6950327-1 Raising Cane's 1032 6950327 7/2/2025 PCB-01 J1 - 4 ( I O 2 ) J1 - 3 ( I O 3 ) J1 - 2 ( I O 4 ) J1 - 1 ( N ) J1 - 5 ( I O 1 ) J1 - 6 ( P 2 ) J1 - 7 ( P 3 ) J1 - 8 ( H 1 ) N1 H1 P2 J4 J3 FOR STANDARD CONTROL PANEL, CONNECT H1, N1 P2 TO LIKE TERMINALS IN ELECTRICAL CONTROL PACKAGEFOR SC OR DCV, CONNECT CAT-5 CABLE FROM RJ-45 INSIDE PCU TO J3 OF ECPM03 PCB. PR - PURPLE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK RD - RED BL - BLUE GY - GRAY OR/BL - ORANGE/BLUE (STRIPE) BL/RD - BLUE/RED (STRIPE)RD/GN - RED/GREEN (STRIPE) GR - GREEN YW - YELLOW WIRE COLOR TO ECPM03 BOARD FAULT OUTPUT NEUTRAL 120 VAC INCOMING POWER 24 VAC RELAY RA-x CB-01 DSW-01 FH1 PCU-AFM WH BK BK BK MO D B U S C O M M U N I C A T I O N CB-01 Circuit Breaker [6] DSW-01 Disconnect Switch [6] PCB-01 PCUAFM - A0018883 [2] Drawing Shown De-energizedTamper switches made C to NO when door is closed (Typical) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 DRAWING NUMBER JOB NUMBER JOB NAME MODEL DATE Installed Options DENOTES INTERNAL WIRING DENOTES FIELD WIRING ** TERMINAL 11 PROVIDES COOLING CONNECTION WH - WHITE RD - RED OR - ORANGE BR - BROWN BL - BLUE BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR NOTES PCU#2-6950327-2 Raising Cane's 1032 6950327 7/2/2025 WH SET THERMOSTAT TS-01 (HEAT) TO 40°F. SET THERMOSTAT TS-02 (COOL) TO 90°F. 120VAC FROM FIRE SYSTEM ECP, MOCP=15 AMPS N1 H1 WH BK TS-02 BL WH R W B MT-02 MT-01 CB-01 TS-01 BK R RDB YW W HS-02 HS-01 T6031A1136 THERMOSTAT T6031A1136 THERMOSTAT S201U-K15 CIRCUIT BREAKER 1976K42 EXHAUST FAN 1976K42 EXHAUST FAN 200WSTPHTR HEATER Component Identification 200WSTPHTR HEATER Description TS-02 TS-01 CB-01 MT-02 MT-01 HS-02 HS-01 Label Location [3] [2] [1] [1] [2] [2] [1] CB-01 INSIDE ECP BOX SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.13 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A 1 2 SC-311110MA PCU-CAS-TANK UTILITY CABINET LEFT PCU CONDITIONED TOP MOUNT UC UTILITY CABINET LEFT HOOD # 1 NO SWITCHES 1 LIGHT 1 FAN 2 OTHER SMART CONTROLS THERMOSTATIC CONTROL W/ RELAY ON/OFF WITH SUPPLY PCU-1 MAU-1 EXHAUST SUPPLY 3 3 7.500 2.000 208 208 22.3 6.1 NO TAG PACKAGE #LOCATION SWITCHES LOCATION QUANTITY OPTION FANS CONTROLLED FAN TAG TYPE ɸ HP VOLT FLA Field Connection Antennas Wired OR Paddle Field Connection to Router OR Ethernet switch Connection for Modbus Factory wired OR Field Wired Terminal Blocks for wired connection Cellular Module Compute module DESCRIPTION OF OPERATION: 6950327 Raising Cane's 1032 SC-311110MA 7/2/2025 INSTALL ECP #1-1 3 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. BREAKER PANEL TO PRIMARY CONTROL PANEL Responsibility: Electrician BREAKER PANEL PRIMARY CONTROL PANEL BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED BREAKER 1PH CONTROL POWER. DO NOT WIRE TO GFCI OR SHUNT TRIP BREAKER. Hot Neutral H1 N1120 V 15 A Ground GND 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 WIRE TO VFD QUICK CONNECTOR BREAKER 3PH MCA: MOCP: LINE LINE Ground PCU-1 SM-1 GND L1 L2 LINE L3208 V 27.9 A 40 A BREAKER 3PH WIRE TO VFD QUICK CONNECTOR MCA: MOCP: LINE LINE 208 V Ground MAU-1 SM-2 GND L4 L5 LINE L67.6 A 15 A BREAKER PANEL TO FANS Responsibility: Electrician BREAKER PANEL FANS POWER TO CONDENSER LINE LINE208-230 20 Amps MAU-1 LINE COND 1 3 PHASE POWER TO CONDENSER LINE LINE208-230 30 Amps MAU-1 LINE COND 2 3 PHASE CONTROL PANEL TO FANS Responsibility: Electrician PRIMARY PANEL FANS Load Wiring WIRE TO VFD QUICK WIRE TO DISCONNECT CONNECTOR MUST HAVE ITS OWN CONDUIT DO NOT SHARE CONDUIT! FLA: HP: VOLT: PCU-101 LOAD LEG 1 LOAD LEG 2 GND GROUND FAN: SM-1 LOAD LEG 3 U1 V1 W1 22.3 7.500 208 V Load Wiring BLACK BLACK BLACK GREEN WIRE TO VFD QUICK CONNECTOR WHITE RED FLA: HP: VOLT: MUST HAVE ITS OWN CONDUIT DO NOT SHARE CONDUIT! IF VFD MOUNTED IN 2ND PANEL, WIRE SF SIGNAL FROM PANEL WITH ECPM03. U2 V2 W2 LOAD LEG 1 LOAD LEG 2 LOAD LEG 3 GND GROUND MAU-101FAN: SM-2 N1 120V NEUTRAL 120V HOT N1 6.1 2.000 208 V H1 POLLUTION UNIT COMM LINK CONTROL IF MULTIPLE PCUs ON JOB, WIRE EACH CAT-5 IN DAISY CHAIN LOOP, WITH END OF LINE TERMINATOR ON LAST UNIT. CAT-5 ETHERNET CABLE EACH ADDITIONAL UNIT MUST HAVE MODBUS ADDRESS SET. INSIDE PCU J3 ECPM03 J3 CONTROL PANEL TO ACCESSORY ITEMS Responsibility: Electrician CONTROL PANEL COMPONENT ALL SWITCHES FACTORY WIRED CAT-5 CONNECTION CONTROL PANEL SWITCHES TO J4 CONTROL PANEL HOOD LIGHTS TO 1400 W MAX WIRE TO J-BOX ON TOP OF HOOD B1 W1 GND BLACK WHITE GREEN HOOD LIGHTS 1 WIRE DIRECTLY TO COMMUNICATION ROUTERCOMM MODULE. NET REQUIRES 1) DHCP 2) UDP PORT 1444 & 1445 OPEN FOR CAT-5 ETHERNET CONNECTION CONTROL PANEL WORLD WIDE TO WEB OUTBOUND TRAFFIC ONLY. -- WIRE TO CONTROL BOARD. INSTALL SENSOR IN ROOM AWAY FROM HEAT SOURCES. DO NOT INSTALL SENSOR CONTROL PANEL ROOM TEMP TO SENSOR ON THE CEILING GRID, SEE MANUAL. GROUPS: T1A T1B ROOM TEMP FACTORY WIRED TEMPERATURE SENSOR. MOUNTED IN HOOD CAPTURE CONTROL PANEL CAPTURE VOLUME TO SENSOR VOLUME. T2A T2B HOOD 1 CAPTURE 1 FACTORY WIRED TEMPERATURE SENSOR. MOUNTED IN HOOD CAPTURE CONTROL PANEL CAPTURE VOLUME TO SENSOR VOLUME. T3A T3B HOOD 1 CAPTURE 2 WIRE TO CONTROL BOARD. SENSOR MOUNTED IN HOOD CAPTURE CONTROL PANEL CAPTURE VOLUME TO SENSOR VOLUME. T4A T4B HOOD 2 CAPTURE 1 WIRE TO CONTROL BOARD. SENSOR MOUNTED IN SUPPLY PLENUM. CONTROL PANEL PSP SENSOR TO T5A T5B HOOD 2 PSP TEMP CONTROL PANEL PSP LED TO LIGHTS WIRE TO J-BOX ON TOP OF PSP. CONNECT TO RESPECTIVE HOOD LIGHTING CIRCUIT. NOTE: DO NOT HOOD LIGHT INPUT MATCH WIRE IN SERIES WITH HOOD LIGHTS. BLACK WHITE GREEN PSP LIGHTS HOT NEUTRAL GROUND CONTROL PANEL GAS VALVE TO 120V ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. GAS N1 HOT TO GAS VALVE NEUTRAL GAS SOLENOID THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE SPECIFICATIONS CONTROL PANEL EXTERNAL SIGNAL FOR SHUNT TRIP ST TERMINAL IS ENERGIZED IN FIRE CONDITION. CONTROL PANEL EXTERNAL SIGNAL FOR CONTACTOR COIL KS TERMINAL IS DE-ENERGIZED IN FIRE CONDITION. ST N1 NEUTRAL FROM SHUNT COIL HOT TO SHUNT COIL SHUNT COIL KS N1 NEUTRAL_TO_CONTACTOR_COIL HOT_TO_CONTACTOR_COIL CONTACTOR_COIL SPARE CONTACTS WILL MAKE CONTROL PANEL ON/OFF WITH DRY CONTACT SUPPLY FAN COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. GROUP 1 SFC1 SFO1 COMMON NORMALLY OPEN SFC2 SFO2 COMMON NORMALLY OPEN CONTROL PANEL EXTERNAL TO SWITCH SIGNAL SWITCH THROUGH BMS WILL ACTIVATE ZONE1 FANS AND LIGHTS H1 IO1 BMS SWITCH C NO CONTROL PANEL GAS VALVE TO 24V DC ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. (NOT NEEDED IF USING 120V GAS VALVE). LGV N1D POSITIVE TO GAS VALVE NEGATIVE GAS SOLENOID DESCRIPTION OF OPERATION: 6950327 Raising Cane's 1032 SC-311110MA 7/2/2025 INSTALL ECP #1-2 3 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. CONTROL PANEL TO FIRE SYSTEM Responsibility: ALARM CONTRACTOR CONTROL PANEL COMPONENT CONTROL PANEL BUILDING SIGNAL FOR FIRE ALARM PANEL AL1 AL2 J9 BUILDING ALARM PANEL FIRE INPUT WIRE DIRECTLY TO CORE CIRCUIT BOARD. AL1 WILL MAKE AL2 IN FIRE CONDITION. CONTROL PANEL BUILDING SIGNAL FOR TROUBLE TROUBLE RELAY CONTACTS WILL MAKE TBC TO TBL IN TROUBLE CONDITION. BUILDING ALARM PANEL ALARM TBC TBL COMMON NORMALLY CLOSED CONTROL PANEL TO FIRE SYSTEM Responsibility: CERTIFIED INSTALLER CONTROL PANEL COMPONENT FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. 21 22 23 24 FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat CONTROL PANEL MOUNTED FIRE TO DUCT DETECTION STAT(S) FIRE STATS CONTROL PANEL SYSTEM PULL TO FIRE STATION MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 is mounted on J10, remove the jumpers and wire in the supervised actuation loop. Microswitch MS-01 is optional for fire system interlock. Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master FS panel(s) in each manual activation loop for simultaneous activation. See Fire system drawings for more information. 101 102 103 104 AUX-01 AU1 AU2 PULL STATION MS-01 C NO Micro SW MAD-01 C NO Manual Actuation Device Adjacent FS Panel CAT-5 CONNECTIONCONTROL PANEL MASTER FS TO BOARD. PLACE END OF LINE PLUG EOL120AIN EMPTY JACK. PN: EOL120A CORE PCB ADDITIONAL DEVICES MAY BE INLINE. ECPM03 UNLESS VFD, PCU, OR OTHER COMPONENT IN SERIES. J3 J5 J6 CONTROL PANEL MASTER FS TO PANEL WIRE TO LIKE TERMINALS IN ALL CORE PANELS THAT MUST ACTIVATE TOGETHER. SET MASTER & SLAVE DIP SWITCHES PER FIRE SYSTEM SHIELDED TWISTED PAIRINTERLOCK NETWORK MASTER CORE MANUAL. CA CB CC BLACK RED SHIELD CA CB CC DESCRIPTION OF OPERATION: 6950327 Raising Cane's 1032 SC-311110MA 7/2/2025 INSTALL ECP #1-3 Fire System #1 TANK FS - 4.0 / Remote - 4.0/4.0/4.0. FS-1: MASTER DESCRIPTION OF OPERATION: 6950327 Raising Cane's 1032 SC-311110MA 7/2/2025 INSTALL ECP #1-4 Fire System #1 TANK FS - 4.0 / Remote - 4.0/4.0/4.0. FS-1: MASTER SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.14 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A DESCRIPTION OF OPERATION: 6950327 Raising Cane's 1032 SC-311110MA 7/2/2025 INSTALL ECP #1-5 Fire System #1 TANK FS - 4.0 / Remote - 4.0/4.0/4.0. FS-1: MASTER WH BK A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CIRCUIT BOARDS MOTOR POWER CIRCUIT PANEL LID COMPONENT LIST LABEL DESCRIPTION PN: ST-X varies Starter PN: OL-X varies Overload PN: C-X varies Contactor PN: TS-x A/CP-PO-T4"-EXPL Duct Thermostat 120 VAC RELAY RA-x 24 VDC RELAY RD-x PN: PS-1 MDP18-24A-1C Power Sup. 24VDC BK PN: RA-x 34.110.0184.0 120V Relay DPDT WH PN: RA-x 34.110.0184.0 120V Relay DPDT GR UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. N1 H1 DC - GN D DC + 8H1 7PCU 6ST 5KS 4KTS 3GAS 2AR1 1N1 120VJ9 5OV1 4SF1 3EF1 2B1 1IO1 120VJ7 AR1 H12x N12x B1 EF1 SF1 BK IO1 BK BK BK JUMPERW1 BK 14AWG BK 64 RD-1 BL PRDC+RO1 PN: RD-x 34.110.0188.0 24VDC Light Relay BK WHSF1RA-2 RD-1 24V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 J6 N1N1 RO 1 FAN PANEL COOLING DRY CONTACTS (SHOWN DE-ENERGIZED) PCU AFM (field wired to end of line) HOOD LIGHTS J3 ECPM03/DAISY CHAIN AR1 H1JUMPER FIRE SYSTEM BK BK BK GAS KS ST NOTE: Configure for PCU AFM control NOTE: Configure ECPM03 for CORE J3 ECPM03/DAISY CHAIN SM-1 SM-2 ECPM03 J10 IL 1 A IL 1 B JUMPER MAKE UP AIR INTERLOCK. 1 2 11 1 JUMPER 1 2 11 1 JUMPER NOTE: All items on ECPM03 J5 line to be daisy chained from one component to the next, with EOL120A at end of line. Place PN: EOL120A in empty RJ45 port. J3 ECPM03 or Previous EOL J5 MASTER CORE RA-2-1 SFC1 SFO1 14 AWG YW RA-2-2 SFC2 SFO2 14 AWG YW 24 X 18 X 8.62 BOX CONTROL INPUT 120V H1=LINE, N1=NEUTRAL, 15A BREAKER. DO NOT CONNECT TO SHUNT TRIP BREAKER. SEE INSTALLATION SCHEMATIC FOR ADDITIONAL REQ. LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN WH / B L BL H1N1 DC - DC + LN -+ PS-01 AC 24V GN D DCKSKSBKKS BK BK GAS ST BKEF1 PR WH GR / Y W WH / B L BL J4 J5J4J5 FAN SECONDARY PANEL COOLING IF NECESSARY EF1 WHBK J1 ECPM03 SCADA WIRED BK RD + - DEST DEST ILB ILC ILA DEST DEST TO ETH CAT-5 PN: SCADA SCADA Module SHDANT Wired to Master CORE (if applicable) Use shielded wire BK RD SD JUMPER ECPM03 J10 IL 2 A IL 2 B TERMINAL GAS USED FOR 120V POWERED GAS VALVES ONLY N1 6950327 Raising Cane's 1... FACTORY SC-311110MA 7/2/2025 ECP #1-6 3 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. BK BK BK BK BK BK BK BK BK BK BK BK U/T1 V/T2 W/T3 L1 L2 L3/N GR GR GND VFD: HP: MTR: FLA: P107: P108: P410: P150: P100: P194: P101: P131: P167: P103: P102: L1 L2 L3 10 AWG 3 PH 40 A 208 V U1 V1 W1 SM-1 ESV552N02TXB571 225 01 01 11 96 00 22.3 7.500 PCU-1 N/A N/A 76.1 75.0 0.0 GND BK BK BK BK BK BK BK BK BK BK BK BK U/T1 V/T2 W/T3 L1 L2 L3/N GR GR GND VFD: HP: MTR: FLA: P107: P108: P410: P150: P100: P194: P101: P131: P167: P103: P102: L4 L5 L6 14 AWG 3 PH 15 A 208 V U2 V2 W2 SM-2 ESV152N02YXB571 225 01 01 21 87 00 6.1 2.000 MAU-1 N/A N/A 52.6 49.2 0.0 GND A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CORE FIRE PROTECTION COMPONENT LIST LABEL DESCRIPTION 120 VAC RELAY RA-x 24 VDC RELAY RD-x 24 VOLT BATTERY PACK 5 AMP FUSE RD SHIELDED TWISTED PAIR PCB-2 J3-2 J4-1 J3-11 J4-3 J4-2 J4-8 J4-9 J4-12 J3-14 J4-5 J3-13 J3-4 J4-6 J3-10 J2-1 J2-2 J2-3 J2-4 J7-2 J7-3 J7-1 J3-1 J3-3 RD RD BR RD MAX 16AWG RD BK ORRD PKRD BRRD RD OR/BL BK 18AWG BK BK J3-5 J1-1 J1-2 RD BK BK RD FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. + + RD BK BK RD Shield BK RD RS-485 CORE INTERLOCK NETWORK. Connection to other CORE Panels or Communication Module. See Installation Schematic for Connection. N1D 3xH1D3x DISCONNECT J1 21 22 23 24 16AWG WHN1 H1 PN: 1606-XLP-60EQ Adjust power supply to 27.5 Volts with an accurate Digital Volt Meter or with an HMI plugged into the CORE board. NL +- PS-02 60W GR BK GND PN: PCB-2 PCBCORE-APP CORE PCB PN: PS-02 1606-XLP-60E CORE POWER SUPPLY PN: WS-x varies Water Solenoid PN: LT-06 WL-1090D1-28V 24V Red Ind. Light PN: LL-01 AQ5510 Surf. Level Sensor PN: AA-01 SCE120LA3FP1B Audible Alarm PN: PB-XX ZB4BA2/ZB4BZ1015 Prime/Reset Switch PN: SW-04 BZ-2RQ1-A2 Tamper Switch PN: SP-1 50000-805 Surfactant Pump PB-01 Prime / Reset RD-20 Trouble Relay RD-17 Fire Relay DRY CONTACTS (SHOWN DE-ENGERGIZED) AA-01 Audible Alarm SW-04 Door Tamper Switch C NO FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. Factory mounted hood sensors will be terminated at junction box on top of hood. PN: GV-1 varies 24v DC Gas Valve INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition. RD-18-1 YW J3-16 J3-8 LT-6 R FIRE INDICATOR DIP Switch ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES. RD/GNRDRD-19 Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS Kill Switch, wire EKC and EKS terminals to like terminals in UDS panel. RD-19-1 EKC EST EKS YW INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition. RD-18-1 YW RD OR/BLRD-18 Auxiliary Interlock Relay PN: FS-XX 12-F28021-000360 Duct Fire Sensor PN: LT-05 WL-1090D3-28V 24V YLW Ind. Light PN: PS-01 Station STI-SS2431 Remote Puill/Push FOR SHIPMENT J10-1 J10-2 J10-3 J10-4 RD BK BK RD 101 102 103 104 MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 should be mounted on J10 if there is no manual actuation device and no microswitch. MAD-01 C NO Manual Actuation Device MS-01 C NO Micro SW 1 2 3 4 5 6 7 8 SW 1 ON PUT END OF LINE PLUG IN EMPTY RJ45 J3 ECPM03 UNLESS PCU AFM OR OTHER COMPONENT IN SERIES. CAT-5 WIRING (MASTER ONLY) FIELD WIRED IF REMOTE PREWIRE PN: RD-XX PLC-RPT-24DC/21 24VDC Phoenix Relay AUX-01 AU1 AU2 Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master CORE panel(s) in each manual activation loop for simultaneous activation. AU1/AU2 will have continuity for 10 seconds if adjacent panel goes into fire condition, activating this CORE Panel but allowing for a reset after 10 seconds. NOTE: AU1/AU2 terminals of CORE Panel should not be wired into its own manual activation loop.Adjacent CORE Panel Master CORE set DIP SW 8 to CLOSED position. Slave CORE with address 1 set DIP SW 8 to CLOSED position. All other CORES set DIP SW 8 OPEN. 18AWG LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN FIRE INDICATOR FAULT CONDITION FLASH CODES 2 Release Solenoid 3 Pressure Switch 4 Auxiliary Fault 5 Microcontroller Fault 6 N/A 7 Supervised Loop 8 Ground Fault 9 Surfactant Low 10 Battery Voltage Low 11 AC Power Failure 12 Door Tamper Switch 13 Test Mode 14 CORE Interlock Network 15 Fault on Hood in Interlock Network 16 Fault on PCU in Interlock Network FIRE ALARM SYSTEM DRY CONTACTS. Termials AL1 & AL2 make in FIRE. To Building Fire Alarm Panel J9 AL1 AL2 J3-7 FIRE SYSTEM DRY CONTACTS. Dry contacts will make C2 to AR2 when system is armed. RD-17-1 C2 AR2 14 AWG YW TROUBLE RELAY. Contact terminals TBC & TBL make if there is trouble. Contact terminals TBC & TOK make if the system is ok. RD-20-1 TBC TBL TOK YW PR RS SW-05-1 Test Armed 3 4 YW RS-1 RELEASE SOLENOID BLBR RD ORSW-05-3 Test Armed 3 4 J4-13 PN: SW-05 ZB5AD2 TEST/ARM Switch J3-10 J3-7 PR RS2 SW-05-2 Test Armed 3 4 YW RS-2 RELEASE SOLENOID BLBR J4-9RDPSORJ4-9 PS-1 PSX WH WH RD PN: PWS-01 24VDC 18W POWER 24VDC Power Suppl CA CB CC AU1AU1 AU2AU2 TR2 PN: MAD-01 DEVICE MANUAL ACTIVATION GAS VALVES SHOULD BE WIRED TO MASTER CORE BOARD ONLY. RDRD GV-1 24V DC Gas ValveLGVPK TERMINAL LGV USED FOR 24VDC POWERED GAS VALVES ONLY. PS-X QTY-1 Pressure Switches PS-1 WIRED IN SERIES. A TERMINAL BLOCK SHOULD BE ADDED BETWEEN EACH PRESSURE SWITCH PRESSURE SWITCHES SHOULD BEQTY-2 (2nd Contact) 6950327 Raising Cane's 1... FACTORY SC-311110MA 7/2/2025 ECP #1-7 Fire System #1 TANK FS - 4.0 / Remote - 4.0/4.0/4.0. FS-1: MASTER A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CORE FIRE PROTECTION COMPONENT LIST LABEL DESCRIPTION 120 VAC RELAY RA-x 24 VDC RELAY RD-x 24 VOLT BATTERY PACK 5 AMP FUSE RD SHIELDED TWISTED PAIR PCB-2 J3-2 J4-1 J3-11 J4-3 J4-2 J4-8 J4-9 J4-12 J3-14 J4-5 J3-13 J3-4 J4-6 J3-10 J2-1 J2-2 J2-3 J2-4 J7-2 J7-3 J7-1 J3-1 J3-3 RD RD BR RD MAX 16AWG RD BK ORRD PKRD BRRD RD OR/BL BK 18AWG BK BK J3-5 J1-1 J1-2 RD BK BK RD FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. + + RD BK BK RD Shield BK RD RS-485 CORE INTERLOCK NETWORK. Connection to other CORE Panels or Communication Module. See Installation Schematic for Connection. N1D 3xH1D3x DISCONNECT J1 21 22 23 24 16AWG WHN1 H1 PN: 1606-XLP-60EQ Adjust power supply to 27.5 Volts with an accurate Digital Volt Meter or with an HMI plugged into the CORE board. NL +- PS-02 60W GR BK GND PN: PCB-2 PCBCORE-APP CORE PCB PN: PS-02 1606-XLP-60E CORE POWER SUPPLY PN: WS-x varies Water Solenoid PN: LT-06 WL-1090D1-28V 24V Red Ind. Light PN: LL-01 AQ5510 Surf. Level Sensor PN: AA-01 SCE120LA3FP1B Audible Alarm PN: PB-XX ZB4BA2/ZB4BZ1015 Prime/Reset Switch PN: SW-04 BZ-2RQ1-A2 Tamper Switch PN: SP-1 50000-805 Surfactant Pump PB-01 Prime / Reset RD-20 Trouble Relay RD-17 Fire Relay DRY CONTACTS (SHOWN DE-ENGERGIZED) AA-01 Audible Alarm SW-04 Door Tamper Switch C NO FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. Factory mounted hood sensors will be terminated at junction box on top of hood. PN: GV-1 varies 24v DC Gas Valve INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition. J3-16 J3-8 LT-6 R FIRE INDICATOR DIP Switch ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES. RD/GNRDRD-19 Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS Kill Switch, wire EKC and EKS terminals to like terminals in UDS panel. RD-19-1 EKC EST EKS YW INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition. RD OR/BLRD-18 Auxiliary Interlock Relay PN: FS-XX 12-F28021-000360 Duct Fire Sensor PN: LT-05 WL-1090D3-28V 24V YLW Ind. Light PN: PS-01 Station STI-SS2431 Remote Puill/Push FOR SHIPMENT J10-1 J10-2 J10-3 J10-4 RD BK BK RD 101 102 103 104 MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 should be mounted on J10 if there is no manual actuation device and no microswitch. MAD-01 C NO Manual Actuation Device MS-01 C NO Micro SW 1 2 3 4 5 6 7 8 SW 1 ON PUT END OF LINE PLUG IN EMPTY RJ45 J3 ECPM03 UNLESS PCU AFM OR OTHER COMPONENT IN SERIES. CAT-5 WIRING (MASTER ONLY) FIELD WIRED IF REMOTE PREWIRE PN: RD-XX PLC-RPT-24DC/21 24VDC Phoenix Relay AUX-01 AU1 AU2 Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master CORE panel(s) in each manual activation loop for simultaneous activation. AU1/AU2 will have continuity for 10 seconds if adjacent panel goes into fire condition, activating this CORE Panel but allowing for a reset after 10 seconds. NOTE: AU1/AU2 terminals of CORE Panel should not be wired into its own manual activation loop.Adjacent CORE Panel Master CORE set DIP SW 8 to CLOSED position. Slave CORE with address 1 set DIP SW 8 to CLOSED position. All other CORES set DIP SW 8 OPEN. 18AWG LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN Wired to PCU AFM Master CORE Wired to FIRE INDICATOR FAULT CONDITION FLASH CODES 2 Release Solenoid 3 Pressure Switch 4 Auxiliary Fault 5 Microcontroller Fault 6 N/A 7 Supervised Loop 8 Ground Fault 9 Surfactant Low 10 Battery Voltage Low 11 AC Power Failure 12 Door Tamper Switch 13 Test Mode 14 CORE Interlock Network 15 Fault on Hood in Interlock Network 16 Fault on PCU in Interlock Network FIRE ALARM SYSTEM DRY CONTACTS. Termials AL1 & AL2 make in FIRE. To Building Fire Alarm Panel J9 AL1 AL2 J3-7 FIRE SYSTEM DRY CONTACTS. Dry contacts will make C2 to AR2 when system is armed. RD-17-1 C2 AR2 14 AWG YW TROUBLE RELAY. Contact terminals TBC & TBL make if there is trouble. Contact terminals TBC & TOK make if the system is ok. RD-20-1 TBC TBL TOK YW RD PS OR J4-9 PN: PS EWC-PRESSURE Pressure Switch PR RS SW-05-1 Test Armed 3 4 YW RS-1 RELEASE SOLENOID BLBR RD ORSW-05-3 Test Armed 3 4 J4-13 PN: SW-05 ZB5AD2 TEST/ARM Switch CAT-5 SCADA TO ETH BK RD + - PN: SCADA SCADA Module WIRED ANT RS2PRSW-05-2 Test Armed 3 4 YW PS-1 Pressure Switch WH WH / B L BL H1N1 DC - DC + LN -+ PWS-01 AC 24V DC PN: PWS-01 24VDC 18W POWER 24VDC Power Suppl CA CB CC AU1AU1 AU2AU2 TR2 CC CB CA PN: MAD-01 DEVICE MANUAL ACTIVATION GAS VALVES SHOULD BE WIRED TO MASTER CORE BOARD ONLY. RDRD GV-1 24V DC Gas ValveLGVPK TERMINAL LGV USED FOR 24VDC POWERED GAS VALVES ONLY. H1 CB-01 BK CB-01 INSIDE ECP BOX, WIRED TO UCPCU BK TO UCPCU PN: CB-01 S201U-K15 15A Circuit Breaker (2nd Contact) BK WHH1 N1 FAN PANEL COOLING *POWER FROM H1/N1 ONLY ON STANDALONE PACKAGE W/O ECP 6950327 Raising Cane's 1... FACTORY PCU-CAS-TANK 7/2/2025 ECP #2-1 PCU Tank-based Fire Protection System equipped with Electronic Detection, and Electronic Activation, utilizing CORE board as a Listed Release Mechanism. Installed in Utility Cabinet with integral prewire panel. 12 X 18 X 8.62 Box SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.15 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.16 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A HORIZONTAL VERTICAL TYPE DUCT DIAMETER SUPPORT SPACING (FT) 2R (18") 8"7' 10"7' 12"7' 14"7' 16"7' 18"5' 20"5' 22"5' DOUBLE WALL FACTORY BUILT DUCTWORK - ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW. - FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE ENTIRE INSTALLATION AND OPERATION MANUAL - DUCTWORK SHALL SLOPE NOT LESS THAN 1/16" PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR. - WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16" PER LINEAR FOOT. 24"5' WALL SUPPORT (FT) CURB SUPPORT (FT) FLOOR SUPPORT (FT) 18'24'24' 3R & 3Z (5"-24")10'24'24' 3Z (26" -36")10'20'20' 26"5' 28"5' 30"5' 32"5' 34"5' 36"5' 2R & 2R HT (5"-16")20'24'24' 7"7' 6"7' 5"7' DO NOT LEAK TEST USING SMOKE BOMBS CONTAINING CHLORINES/CHLORIDES. CONSULT WITH CAPTIVEAIRE FOR PROPER LEAK TESTING METHODS. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.17 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A 20" DW1620SADKIT - HORIZONTAL SUPPORTS 28" DW2428SADKIT - HORIZONTAL SUPPORTS DW2026DWCHASESUPASY - CHASEWAY SUPPORT 5" MAX 34 1/4" 34 1/4" 30" DW2630SADKIT - HORIZONTAL SUPPORTS SUPPORT SYSTEM DETAILS #1 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.18 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A H1-E1 H1-E2H2-E1 P10 P12 P13 P23 P24 P25 P26 P27 P28 P29 P3 P32 P33 P34 P35 P36P4P5P6P7P8P9 45.1" 176.5"MAX 169" 162"MIN 115.5"MAX 112" 78"MIN 82.1" 45.06" 41.00 102.8"36.95"15.79"29.22"17.79" 247.6" 16.79" 139.5"MAX 136" 102"MIN 141.5"MAX 138" 104"MIN 152.5"MAX 149" 115"MIN 152.5"MAX 149" 115"MIN 45.06" 176.5"MAX 169" 162"MIN 115.5"MAX 112" 78"MIN 82.1" 45.1" 41.00 102.8"36.95"15.79"29.22"17.79" 247.6" 16.79" 139.5"MAX 136" 102"MIN 141.5"MAX 138" 104"MIN 152.5"MAX 149" 115"MIN 152.5"MAX 149" 115"MIN 176.5"MAX 169" 162"MIN 45.1"45.06" 115.5"MAX 112" 78"MIN 82.1" 41.00 102.8"36.95"15.79"29.22"17.79" 247.6" 16.79" 139.5"MAX 136" 102"MIN 141.5"MAX 138" 104"MIN 152.5"MAX 149" 115"MIN 152.5"MAX 149" 115"MIN DUCTWORK #1 FRONT VIEW SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.19 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A H1-E1 H2-E1 P1 P16P17P19 P2P22 P26 P27 P28 P33 P35 P37 P4 92.5"MAX 70" 55"MIN 65.2" 47.5"MAX 42" 33"MIN 115.5"MAX 112" 78"MIN 28.5"MAX 23" 14"MIN 157.5"MAX 135" 120"MIN 92.5"MAX 70" 55"MIN 65.2" 47.5"MAX 42" 33"MIN 115.5"MAX 112" 78"MIN 28.5"MAX 23" 14"MIN 157.5"MAX 135" 120"MIN 47.5"MAX 42" 33"MIN65.2" 92.5"MAX 70" 55"MIN 115.5"MAX 112" 78"MIN 28.5"MAX 23" 14"MIN 157.5"MAX 135" 120"MIN DUCTWORK #1 SIDE VIEW P1 P10 P12 P13 P14 P15 P17 P18 P19 P2 P20P21P22 P23 P24 P25 P3 P32P33 P34 P35 P36 P37 P4 P5 P6 P7 P8P9 45.05" 92.5"MAX 70" 55"MIN 65.01" 176.5"MAX 169" 162"MIN 47.5"MAX 42" 33"MIN 82.01" 45.01"45.01" 92.5"MAX 70" 55"MIN 65.01" 176.5"MAX 169" 162"MIN 47.5"MAX 42" 33"MIN 82.01" 45.05" 47.5"MAX 42" 33"MIN 176.5"MAX 169" 162"MIN 65.01" 92.5"MAX 70" 55"MIN 45.05"45.01" 82.01" DUCTWORK #1 TOP VIEW SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.20 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A H1-E1 H1-E2 H2-E1 P1 P10 P12 P13 P14 P15 P16 P17 P19 P2 P20 P21 P22 P23 P24 P25 P26 P27 P28 P29 P3 P30 P32 P33 P35 P36 P37 P4 P5 P6 P7 P8 P9 DUCTWORK #1 SE VIEW SYSTEM DESIGN VERIFICATION (SDV) IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS HAD A COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL. TYPICALLY, THE SDV WILL BE PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE. ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP CHARGES. DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER. SHOULD A RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE SALES OFFICE WILL BE NOTIFIED. THERE WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 6950327 MASTER DRAWING Ra i s i n g C a n e ' s 1 0 3 2 SA N T A A N A , C A , 9 2 7 0 1 Lo u i s i a n a O f f i c e 59 0 4 0 A m b e r S t r e e t , S u i t e B , S l i d e l l , L A , 7 0 4 6 1 P H O N E : ( 9 8 5 ) 7 8 1 - 4 1 0 7 F A X : 9 1 9 7 4 7 5 6 3 7 E M A I L : r e g 2 7 @ c a p t i v e a i r e . c o m M3.21 HOOD DRAWINGS Te l e : 9 7 2 - 7 6 9 - 3 1 0 0 F a x : 9 7 2 - 7 6 9 - 3 1 0 1 68 0 0 B i s h o p R o a d , P l a n o , T X 7 5 0 2 4 Date: Project Number: Sheet Number: Drawn By: Store: Re s t a u r a n t S u p p o r t O f f i c e RAC23003.0 07.12.2024 MAM & JJD Sheet Title: 1 07.01.2024 VERSION 2024-1.0 RELEASE Prototype : Date Issued:Bulletin Number: Design Bulletin Updates: Prototype Issue Date: - 2 3 REVISIONS: 4 5 6 7 A 9 Kitchen Issue Date: 10 Raising Cane's Restaurant #C1032 1303 N. Bristol st. Santa Ana, CA 92706 P6E-HV Scheme B 09 / 1 2 / 2 0 2 5 P E R M I T R E V I S I O N - B U L L E T I N 1 09/05/24 BLDG. SUBMITTAL PERMIT SET P6E-AV SCHEME B 2024-1.0 07.01.2024 Check By:MMM 07.01.2024 09/27/24 PLANNING RESPONSE 11/01/24 HEALTH DEP. RESUBMITTAL 12/12/24 HEALTH DEP. RESUBMITTAL 1/20/25 BUILDING. RESUBMITTAL 2/21/25 BUILDING. RESUBMITTAL 05/02/2025 BID SET 06/25/2025 CONSTRUCTION SET 09/12/2025 PERMIT REVISION Professional of Record: 19401 40TH AVE W SUITE 420 LYNNWOOD, WA 98036 CONTACT: MARK MANGLICMOT, P.E. (425) 516-7882 MMANGLICMOT@PMDGINC.COM 09/12/25 MARK MANGLICMOT, PE A