SCOPE OF WORK GENERAL NOTES
VICINITY MAPABBREVIATIONS
A AMPERE
AC ALTERNATING CURRENT
AFC ARC FAULT CIRCUIT INTERUPTER
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT
(E)EXISTING
ESS ENERGY STORAGE SYSTEM
MSP MAIN SERVICE PANEL
(N)NEW
PRE-FAB PRE-FABRICATED
PSF POUNDS PER SQUARE FOOT
PV PHOTOVOLTAIC
RSD RAPID SHUTDOWN DEVICE
TL TRANSFORMERLESS
V VOLTS
W WATTS
SHEET INDEX
REV NAME DATE COMMENTS
• ALL WORK SHALL COMPLY WITH 2022 CRC/CBC/CEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND
INSTALLATION INSTRUCTIONS.
• PHOTOVOLTAIC SYSTEM WILL COMPLY WITH CEC 2022.
• ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH CEC 2022.
• PHOTOVOLTAIC SYSTEM IS FUNCTIONALLY GROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE
INVERTER. SYSTEM COMPLIES WITH 690.41(A).
• MODULES CONFORM TO AND ARE LISTED UNDER UL 61730.
• INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
• RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
• SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED.
• RAPID SHUTDOWN SYSTEM IN COMPLIANCE WITH CEC 2022 690.12(B)(1) WHERE CONDUCTORS OUTSIDE OF THE
ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE
THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS
• CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D).
COVER SHEET
PV-1.0
#ESTAMPCS
#SSTAMPCS
• STANDARD SCOPE NOTES:
• ENERGY STORAGE SYSTEM: (2) TESLA: POWERWALL 3 (AC
COUPLED) 1707000-XX-Y : 13.5 kWh PER PW3
TOTAL ENERGY CAPACITY (IN kWh): 27kWH
• EXISTING SOLAR SYSTEM INSTALLED.
POWER-CONTROLLED SYSTEM (PCS) ENABLED EQUIPMENT
INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS
NEW 225A LOAD CENTER
PAGE # DESCRIPTION
PV-1.0 COVER SHEET
PV-2.0 SITE PLAN
PV-4.0 ELECTRICAL
PV-4.1 ELECTRICAL
PV-4.2 ELECTRICAL CALCS
PV-4.3 PANEL SCHEDULE
PV-5.0 SIGNAGE
PV-5.1 SIGNAGE 2
B1B1
Template_version_v5_2025.04.08
PAGE
REV: B1 7/16/2025
JOSE GUERRERO
901 WESTWOOD AVE SANTA
ANA CA 92703
PROJECT NUMBER:
109R-901GUER2
SHEET
DESIGNER:
JOHNPAUL JOSHY
CUSTOMER RESIDENCE:
TEL. (657) 731-4773
APN: 405-231-22
(415) 580-6920 ex3
Template_version_v5_2025.04.08
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
PL
PL
PLPLPLPL
PL
PL
PL PL PL PL
ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS
IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE
SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET
EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE
DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE
FIRE TESTING.
SITE PLAN
PV-2.0
#SSTAMPSP
#ESTAMPSP
POWERWALL ENERGY
STORAGE SYSTEM (ESS)
BG BACKUP GATEWAY
GP GENERATION PANEL
ELECTRIC VEHICLE
SUPPLY EQUPMENTEV
MAIN PANEL
INVERTER(S)
AC DISCONNECT(S)
DC DISCONNECT(S)
SUNRUN METER
DEDICATED PV METER
SERVICE ENTRANCE
INTERIOR EQUIPMENT
SHOWN AS DASHED
SE
MP
SM
PM
INV
AC
DC
SUB-PANELSP
CB IQ COMBINER BOX
METER ADAPTERMA
GROUNDING
ELECTRODE
ENERGY STORAGE
SYSTEM
BP BACKUP LOADS PANEL
BI BACKUP INTERFACE 1 COMMUNICATION
WIRESAM
MD MICROGRID
INTERCONNECT DEVICE
ACREL METER
SOLAREDGE METERSEMPV LOAD CENTERLC
LEGEND
SCALE: NTS
NOTE: NOT ALL ITEMS IN LEGEND
WILL APPEAR IN SITE PLAN
RSD
EXTERNAL
RAPID
SHUTDOWN
SWITCH
(E) CHIMNEY
SITE PLAN - SCALE = 3/64" = 1'-0"
AC
MDMP
SE
(E) RESIDENCE
(E) GATE (TYP)
(E) FENCE
(E) PV EQUIPMENT
(E) PV ARRAY (TYP)
RSD
INV
AC
(E) DETACHED
STRUCTURE (TYP)
(E) PATIO (TYP)
AC
ACCB
(E) PV EQUIPMENT
WESTWOOD AVE
LC
B1
B1
B1
Template_version_v5_2025.04.08
PAGE
REV: B1 7/16/2025
JOSE GUERRERO
901 WESTWOOD AVE SANTA
ANA CA 92703
PROJECT NUMBER:
109R-901GUER2
SHEET
DESIGNER:
JOHNPAUL JOSHY
CUSTOMER RESIDENCE:
TEL. (657) 731-4773
APN: 405-231-22
(415) 580-6920 ex3
Template_version_v5_2025.04.08
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46J-BOX
18 Jinko Solar:
JKM320M-60HBL
EE
Existing SolarEdge
Technologies:
SE7600H-USE
Existing Inverter(s)
J-BOX
13 JA Solar: JAM54S31-390/MR
(13) Enphase Energy: IQ7PLUS-72-x-US
EE
Exising Enphase Combiner Panel
E
(E) AC
DISCONNECT
E
(N) TESLA REMOTE METER
(1) SOLAR PV CURRENT TRANSFORMER
C
FACILITY
GROUND
EXISTING 200A
MAIN BREAKER
END FED
EXISTING 200A
MAIN PANEL
225A BUS
120/240VAC,
SINGLE
PHASE
SERVICE
2
NEW 225A LOAD CENTER
(2) (N) 60A ESS BREAKER
(E) 40A PV BREAKER
(E) 20A PV BREAKER
C
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A , 2P
120/240VAC
1
TESLA
POWERWALL 3 1707000-XX-Y
TESLA: POWERWALL
3 1707000-XX-Y
(AC COUPLED)
11500 WATT
INVERTER
LOAD RATED DC
DISCONNECT WITH
AFCI RAPID
SHUTDOWN
COMPLIANT
1
B
(N) IMO PE69-3020,
DISCONNECT
SWITCH, 3P, 16A
RSD
TESLA
POWERWALL 3 1707000-XX-Y
TESLA: POWERWALL
(AC COUPLED)
3 1707000-XX-Y
11500 WATT
INVERTER
LOAD RATED DC
DISCONNECT WITH
AFCI RAPID
SHUTDOWN
COMPLIANT
1
RSD
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A , 2P
120/240VAC
1
B
200A
(E) AC
DISCONNECT
E
• POINT OF INTERCONNECTION: CEC 2022: 705.3 LOAD BREAKER AT OPPOSITE END OF BUSBAR
• METER NUMBER:222013-005604
• EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS
• NOTE: TOTAL (E+N) PV BACKFEED = 180A USED FOR INTERCONNECTION CALCULATIONS
M
TESLA
BACKUP
SWITCH
20A
40A
60A
60A
PV-4.0
ELECTRICAL
#ESTAMP
B1
POWER CONTROL SYSTEM (PCS):
• A PCS IS INSTALLED IN ACCORDANCE WITH CEC 2022 705.13
• THE PCS SHALL LIMIT GENERATION SOURCE OUTPUT SUCH THAT CURRENT
FROM ALL SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY
BUSBAR OR CONDUCTOR SUPPLIED BY THE POWER PRODUCTION SOURCES
• ANY BUSBAR OR CONDUCTOR ON THE LOAD SIDE OF THE SERVICE
DISCONNECT NOT MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE
705.12.
• ACCESS TO PCS CONTROLS IS RESTRICTED TO QUALIFIED PERSONS IN
ACCORDANCE WITH 240.6(C).
• ENERGY STORAGE SYSTEM: (1) TESLA: POWERWALL 3 1707000-XX-Y
• ENABLE PCS
SETPOINTS:
- 160 A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL
- 0 A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120%
COMPLIANT)
B1
B1
Template_version_v5_2025.04.08
PAGE
REV: B1 7/16/2025
JOSE GUERRERO
901 WESTWOOD AVE SANTA
ANA CA 92703
PROJECT NUMBER:
109R-901GUER2
SHEET
DESIGNER:
JOHNPAUL JOSHY
CUSTOMER RESIDENCE:
TEL. (657) 731-4773
APN: 405-231-22
(415) 580-6920 ex3
Template_version_v5_2025.04.08
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
CONDUIT SCHEDULE
TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT
E EXISTING
1 Battery Output (2) 6 AWG
THHN/THWN-2
(1) 6 AWG
THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT
2 Load Center (2) 3/0 AWG
THHN/THWN-2
(1) 3/0 AWG
THHN/THWN-2 4 AWG THHN/THWN-2 2 EMT
#ESTAMP
CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS
RODS OR COLD WATER GAS BOND
IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION
APPLIES PER 2019 CEC 210.12
ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE
IDENTIFIED, GROUPED, AND EQUIPPED WITH A 2-POLE
OCPD BREAKER PER CEC 210.4(B,D).
PV-4.1
ELECTRICAL
B1
Template_version_v5_2025.04.08
PAGE
REV: B1 7/16/2025
JOSE GUERRERO
901 WESTWOOD AVE SANTA
ANA CA 92703
PROJECT NUMBER:
109R-901GUER2
SHEET
DESIGNER:
JOHNPAUL JOSHY
CUSTOMER RESIDENCE:
TEL. (657) 731-4773
APN: 405-231-22
(415) 580-6920 ex3
Template_version_v5_2025.04.08
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
ALLOWABLE BACKFEED
ALLOWABLE BACKFEED = MAIN BREAKER RATING = 200A
200A ≤ 200A → INTERCONNECTION MEETS CEC 2022 705.13 REQUIREMENTS
WIRE AMPACITY CALCULATED FROM 310.15(B)(16) & (17) AS APPROPRIATE WITH AMBIENT
TEMPERATURE CALCULATIONS FROM 310.15(B)(3)(C) AND RACEWAY FILL ADJUSTMENTS
FROM 310.15(B)(3)(A). CONDUIT ON THE ROOF SHALL BE INSTALLED NO LESS THAN 1" ABOVE
THE ROOF DECK. PV CIRCUIT CONDUCTOR AMPACITY IS CONSTRAINED USING THE 75°C
COLUMN WITH THE CONTINUOUS DUTY UPRATING OR THE 90°C COLUMN WITH THE
RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS WITHOUT THE
CONTINUOUS DUTY UPRATING PER 690.8(B), WHICHEVER RESULTS WITH A LARGER WIRE
SIZE. NON-PV CIRCUIT CONDUCTORS USE THE AMPACITY IN THE 75°C COLUMN OR THE 90°C
COLUMN WITH THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS,
WHICHEVER IS LESS (110.14(C) & 310.15(A)(2)). THE RATING OF THE CONDUCTOR AFTER
ADJUSTMENTS SHALL BE GREATER THAN, OR EQUAL TO, THE CONTINUOUS DUTY UPRATED
CURRENT.
CALC EX: WIRE AMPACITY X AMBIENT TEMP. CORR. FACTOR X CONDUIT FILL ADJ. FACTOR >=
OUTPUT CURRENT
•TAG 1: BATTERY OUTPUT: 6 AWG RATED 65A, 68.25A >= 60A
•TAG 2: LOAD CENTER FEEDER: 3/0 AWG RATED 200A, 204.75A >= 200A
PV-4.2
ELECTRICAL CALCS
B1
B1
Template_version_v5_2025.04.08
PAGE
REV: C 8/26/2025
JOSE GUERRERO
901 WESTWOOD AVE SANTA
ANA CA 92703
PROJECT NUMBER:
109R-901GUER2
SHEET
DESIGNER:
JOHNPAUL JOSHY
CUSTOMER RESIDENCE:
TEL. (657) 731-4773
APN: 405-231-22
(415) 580-6920 ex3
Template_version_v5_2025.04.08
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
40
20
20
15
20
0
LIGHTING AND
RECEPTACLE
OTHER
ESS BREAKER
FUTURE 225A/200A MAIN
PANEL
(E) PV
ESS BREAKER
15
25
20
20
15
LIGHTING AND
RECEPTACLE
LIGHTING AND
RECEPTACLE
LIGHTING AND
RECEPTACLE
LIGHTING AND
RECEPTACLE
LIGHTING AND
RECEPTACLE
LIGHTING AND
RECEPTACLE
OTHER
60
60
40
20
0
(N) FEEDER
BREAKER
20TRM
PANEL SCHEDULE
PV-4.3
#ESTAMP
MAIN BREAKER
(N) 225A LOAD CENTER
20 (E) PV
C
Template_version_v5_2025.04.08
PAGE
REV: B1 7/16/2025
JOSE GUERRERO
901 WESTWOOD AVE SANTA
ANA CA 92703
PROJECT NUMBER:
109R-901GUER2
SHEET
DESIGNER:
JOHNPAUL JOSHY
CUSTOMER RESIDENCE:
TEL. (657) 731-4773
APN: 405-231-22
(415) 580-6920 ex3
Template_version_v5_2025.04.08
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
NOMINAL ESS VOLTAGE VAC
LABEL LOCATION:
ENERGY STORAGE SYSTEM
PER CODE(S): 2020 NEC 706.15(C), 2022 CEC 706.15(C)
120/240
520 VDCMAXIMUM ESS DC VOLTAGE:60
ENERGY STORAGE SYSTEM DISCONNECT
SIGNAGE
PV-5.0
#ESTAMP
WARNING!
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS
OCPD (IF APPLICABLE).
PER CODE(S): NEC 2020: 705.12(B)(3)(2),
CEC 2022: 705.12(B)(3)(2)
NOTES AND SPECIFICATIONS:
·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
·DO NOT COVER EXISTING MANUFACTURER LABELS.
ELECTRICAL SHOCK HAZARD
WARNING
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S),
AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020: 690.13(B), CEC
2022: 690.13(B)
!
WARNING!
SOURCES: UTILITY GRID,
BATTERY AND PV SOLAR
ELECTRIC SYSTEM
THREE POWER SUPPLY
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): NEC 2020: 705.12(C), CEC
2022: 705.12(C)
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54
PV SYSTEM DISCONNECT
INVERTER 1
LABEL LOCATION:
REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4
LOCATION: MAIN PANEL
SIZE: 4.25" X 1.25"
PCS CONTROLLED CURRENT SETTING: 160 A
THE MAXIMUM OUTPUT CURRENT FROM THIS
SYSTEM IS CONTROLLED ELECTRONICALLY.
REFER TO THE MANUFACTURER'S
INSTRUCTIONS FOR MORE INFORMATION.
WARNING: THIS SENSOR IS PART
OF A POWER CONTROL SYSTEM.
DO NOT REMOVE. REPLACE ONLY
WITH THE SAME TYPE AND RATING.
WARNING: THIS SENSOR IS PART
OF A POWER CONTROL SYSTEM.
DO NOT REMOVE. REPLACE ONLY
WITH THE SAME TYPE AND RATING.
REQUIREMENT: UL 1741, SECTION 206.3
LOCATION: AROUND THE CT WIRE BY CLAMP
SIZE 4.25" X 0.75"
B1
B1
Template_version_v5_2025.04.08
PAGE
REV: C 8/26/2025
JOSE GUERRERO
901 WESTWOOD AVE SANTA
ANA CA 92703
PROJECT NUMBER:
109R-901GUER2
SHEET
DESIGNER:
JOHNPAUL JOSHY
CUSTOMER RESIDENCE:
TEL. (657) 731-4773
APN: 405-231-22
(415) 580-6920 ex3
Template_version_v5_2025.04.08
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SIGNAGE 2
PV-5.1
#ESTAMP
CAUTION:
901 WESTWOOD AVE SANTA ANA CA 92703
PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10
MULTIPLE SOURCES OF POWER
PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10
MAIN SERVICE ENTRANCE
SYSTEM SHUTDOWN
DISCONNECT( 1 OF 3)
PV SYSTEM(S) ARE EQUIPPED
WITH RAPID SHUTDOWN
DEVICE(S)
SYSTEM SHUTDOWN
DISCONNECT( 2 OF 3)
SYSTEM SHUTDOWN
DISCONNECT( 3 OF 3)
INVERTER & ENERGY STORAGE UNIT (EXT)
INVERTER & ENERGY STORAGE UNIT (EXT)
AC DISCONNECT (EXT)
AC DISCONNECT (EXT)
C