Loading...
HomeMy WebLinkAbout901 N Westwood - Plan (2)Template_version_v5_2025.04.08 PAGE REV: B1 7/16/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SCOPE OF WORK GENERAL NOTES VICINITY MAPABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N)NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX REV NAME DATE COMMENTS • ALL WORK SHALL COMPLY WITH 2022 CRC/CBC/CEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH CEC 2022. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH CEC 2022. • PHOTOVOLTAIC SYSTEM IS FUNCTIONALLY GROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A). • MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN SYSTEM IN COMPLIANCE WITH CEC 2022 690.12(B)(1) WHERE CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D). COVER SHEET PV-1.0 #ESTAMPCS #SSTAMPCS • STANDARD SCOPE NOTES: • ENERGY STORAGE SYSTEM: (2) TESLA: POWERWALL 3 (AC COUPLED) 1707000-XX-Y : 13.5 kWh PER PW3 TOTAL ENERGY CAPACITY (IN kWh): 27kWH • EXISTING SOLAR SYSTEM INSTALLED. POWER-CONTROLLED SYSTEM (PCS) ENABLED EQUIPMENT INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS NEW 225A LOAD CENTER PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL PV-4.2 ELECTRICAL CALCS PV-4.3 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE 2 B1B1 Template_version_v5_2025.04.08 PAGE REV: B1 7/16/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL PLPLPLPL PL PL PL PL PL PL ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP POWERWALL ENERGY STORAGE SYSTEM (ESS) BG BACKUP GATEWAY GP GENERATION PANEL ELECTRIC VEHICLE SUPPLY EQUPMENTEV MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) SUNRUN METER DEDICATED PV METER SERVICE ENTRANCE INTERIOR EQUIPMENT SHOWN AS DASHED SE MP SM PM INV AC DC SUB-PANELSP CB IQ COMBINER BOX METER ADAPTERMA GROUNDING ELECTRODE ENERGY STORAGE SYSTEM BP BACKUP LOADS PANEL BI BACKUP INTERFACE 1 COMMUNICATION WIRESAM MD MICROGRID INTERCONNECT DEVICE ACREL METER SOLAREDGE METERSEMPV LOAD CENTERLC LEGEND SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND WILL APPEAR IN SITE PLAN RSD EXTERNAL RAPID SHUTDOWN SWITCH (E) CHIMNEY SITE PLAN - SCALE = 3/64" = 1'-0" AC MDMP SE (E) RESIDENCE (E) GATE (TYP) (E) FENCE (E) PV EQUIPMENT (E) PV ARRAY (TYP) RSD INV AC (E) DETACHED STRUCTURE (TYP) (E) PATIO (TYP) AC ACCB (E) PV EQUIPMENT WESTWOOD AVE LC B1 B1 B1 Template_version_v5_2025.04.08 PAGE REV: B1 7/16/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46J-BOX 18 Jinko Solar: JKM320M-60HBL EE Existing SolarEdge Technologies: SE7600H-USE Existing Inverter(s) J-BOX 13 JA Solar: JAM54S31-390/MR (13) Enphase Energy: IQ7PLUS-72-x-US EE Exising Enphase Combiner Panel E (E) AC DISCONNECT E (N) TESLA REMOTE METER (1) SOLAR PV CURRENT TRANSFORMER C FACILITY GROUND EXISTING 200A MAIN BREAKER END FED EXISTING 200A MAIN PANEL 225A BUS 120/240VAC, SINGLE PHASE SERVICE 2 NEW 225A LOAD CENTER (2) (N) 60A ESS BREAKER (E) 40A PV BREAKER (E) 20A PV BREAKER C (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 1 TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL 3 1707000-XX-Y (AC COUPLED) 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 1 B (N) IMO PE69-3020, DISCONNECT SWITCH, 3P, 16A RSD TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL (AC COUPLED) 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 1 RSD (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 1 B 200A (E) AC DISCONNECT E • POINT OF INTERCONNECTION: CEC 2022: 705.3 LOAD BREAKER AT OPPOSITE END OF BUSBAR • METER NUMBER:222013-005604 • EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS • NOTE: TOTAL (E+N) PV BACKFEED = 180A USED FOR INTERCONNECTION CALCULATIONS M TESLA BACKUP SWITCH 20A 40A 60A 60A PV-4.0 ELECTRICAL #ESTAMP B1 POWER CONTROL SYSTEM (PCS): • A PCS IS INSTALLED IN ACCORDANCE WITH CEC 2022 705.13 • THE PCS SHALL LIMIT GENERATION SOURCE OUTPUT SUCH THAT CURRENT FROM ALL SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR SUPPLIED BY THE POWER PRODUCTION SOURCES • ANY BUSBAR OR CONDUCTOR ON THE LOAD SIDE OF THE SERVICE DISCONNECT NOT MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. • ACCESS TO PCS CONTROLS IS RESTRICTED TO QUALIFIED PERSONS IN ACCORDANCE WITH 240.6(C). • ENERGY STORAGE SYSTEM: (1) TESLA: POWERWALL 3 1707000-XX-Y • ENABLE PCS SETPOINTS: - 160 A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL - 0 A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) B1 B1 Template_version_v5_2025.04.08 PAGE REV: B1 7/16/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT E EXISTING 1 Battery Output (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT 2 Load Center (2) 3/0 AWG THHN/THWN-2 (1) 3/0 AWG THHN/THWN-2 4 AWG THHN/THWN-2 2 EMT #ESTAMP CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER 2019 CEC 210.12 ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D). PV-4.1 ELECTRICAL B1 Template_version_v5_2025.04.08 PAGE REV: B1 7/16/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 ALLOWABLE BACKFEED ALLOWABLE BACKFEED = MAIN BREAKER RATING = 200A 200A ≤ 200A → INTERCONNECTION MEETS CEC 2022 705.13 REQUIREMENTS WIRE AMPACITY CALCULATED FROM 310.15(B)(16) & (17) AS APPROPRIATE WITH AMBIENT TEMPERATURE CALCULATIONS FROM 310.15(B)(3)(C) AND RACEWAY FILL ADJUSTMENTS FROM 310.15(B)(3)(A). CONDUIT ON THE ROOF SHALL BE INSTALLED NO LESS THAN 1" ABOVE THE ROOF DECK. PV CIRCUIT CONDUCTOR AMPACITY IS CONSTRAINED USING THE 75°C COLUMN WITH THE CONTINUOUS DUTY UPRATING OR THE 90°C COLUMN WITH THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS WITHOUT THE CONTINUOUS DUTY UPRATING PER 690.8(B), WHICHEVER RESULTS WITH A LARGER WIRE SIZE. NON-PV CIRCUIT CONDUCTORS USE THE AMPACITY IN THE 75°C COLUMN OR THE 90°C COLUMN WITH THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS, WHICHEVER IS LESS (110.14(C) & 310.15(A)(2)). THE RATING OF THE CONDUCTOR AFTER ADJUSTMENTS SHALL BE GREATER THAN, OR EQUAL TO, THE CONTINUOUS DUTY UPRATED CURRENT. CALC EX: WIRE AMPACITY X AMBIENT TEMP. CORR. FACTOR X CONDUIT FILL ADJ. FACTOR >= OUTPUT CURRENT •TAG 1: BATTERY OUTPUT: 6 AWG RATED 65A, 68.25A >= 60A •TAG 2: LOAD CENTER FEEDER: 3/0 AWG RATED 200A, 204.75A >= 200A PV-4.2 ELECTRICAL CALCS B1 B1 Template_version_v5_2025.04.08 PAGE REV: C 8/26/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 40 20 20 15 20 0 LIGHTING AND RECEPTACLE OTHER ESS BREAKER FUTURE 225A/200A MAIN PANEL (E) PV ESS BREAKER 15 25 20 20 15 LIGHTING AND RECEPTACLE LIGHTING AND RECEPTACLE LIGHTING AND RECEPTACLE LIGHTING AND RECEPTACLE LIGHTING AND RECEPTACLE LIGHTING AND RECEPTACLE OTHER 60 60 40 20 0 (N) FEEDER BREAKER 20TRM PANEL SCHEDULE PV-4.3 #ESTAMP MAIN BREAKER (N) 225A LOAD CENTER 20 (E) PV C Template_version_v5_2025.04.08 PAGE REV: B1 7/16/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 NOMINAL ESS VOLTAGE VAC LABEL LOCATION: ENERGY STORAGE SYSTEM PER CODE(S): 2020 NEC 706.15(C), 2022 CEC 706.15(C) 120/240 520 VDCMAXIMUM ESS DC VOLTAGE:60 ENERGY STORAGE SYSTEM DISCONNECT SIGNAGE PV-5.0 #ESTAMP WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2), CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. ELECTRICAL SHOCK HAZARD WARNING LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC 2022: 690.13(B) ! WARNING! SOURCES: UTILITY GRID, BATTERY AND PV SOLAR ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC 2022: 705.12(C) LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT INVERTER 1 LABEL LOCATION: REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4 LOCATION: MAIN PANEL SIZE: 4.25" X 1.25" PCS CONTROLLED CURRENT SETTING: 160 A THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM IS CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION. WARNING: THIS SENSOR IS PART OF A POWER CONTROL SYSTEM. DO NOT REMOVE. REPLACE ONLY WITH THE SAME TYPE AND RATING. WARNING: THIS SENSOR IS PART OF A POWER CONTROL SYSTEM. DO NOT REMOVE. REPLACE ONLY WITH THE SAME TYPE AND RATING. REQUIREMENT: UL 1741, SECTION 206.3 LOCATION: AROUND THE CT WIRE BY CLAMP SIZE 4.25" X 0.75" B1 B1 Template_version_v5_2025.04.08 PAGE REV: C 8/26/2025 JOSE GUERRERO 901 WESTWOOD AVE SANTA ANA CA 92703 PROJECT NUMBER: 109R-901GUER2 SHEET DESIGNER: JOHNPAUL JOSHY CUSTOMER RESIDENCE: TEL. (657) 731-4773 APN: 405-231-22 (415) 580-6920 ex3 Template_version_v5_2025.04.08 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE 2 PV-5.1 #ESTAMP CAUTION: 901 WESTWOOD AVE SANTA ANA CA 92703 PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MAIN SERVICE ENTRANCE SYSTEM SHUTDOWN DISCONNECT( 1 OF 3) PV SYSTEM(S) ARE EQUIPPED WITH RAPID SHUTDOWN DEVICE(S) SYSTEM SHUTDOWN DISCONNECT( 2 OF 3) SYSTEM SHUTDOWN DISCONNECT( 3 OF 3) INVERTER & ENERGY STORAGE UNIT (EXT) INVERTER & ENERGY STORAGE UNIT (EXT) AC DISCONNECT (EXT) AC DISCONNECT (EXT) C