Loading...
HomeMy WebLinkAbout3941 S Bristol St - PlanCOVER SHEET E-01 E-01 E-02 E-03 E-04 E-05 E-06 E-07 E-08 E-09 E-10 SCOPE OF WORK 1.EV CHARGERS - PROVIDE AND INSTALL: 1.1.(5) NEW LOOP INFINITY FLASH 300KW, DUAL-PORT, PEDESTAL MOUNT, EV CHARGERS. (10 PORTS TOTAL) 2.ELECTRICAL EQUIPMENT - PROVIDE AND INSTALL: 2.1.(1) NEW UTILITY TRANSFORMER. 2.2.(1) NEW MSB: 3000A, 480/277V, 3ɸ, 4W, 65kAIC, NEMA 3R ENCLOSURE. 2.2.1. (1) NEW EV METER. 2.2.2. (1) NEW 3000A, 480V, 3P, 65kAIC MAIN CIRCUIT BREAKER. 2.2.3 (5) NEW LOOP INFINITY FLASH POWER CABINET, 480V, 3ɸ, 3W, 65kAIC, NEMA 3R ENCLOSURES. 2.2.4. (5) NEW 600A, 480V, 3P, 42kAIC CIRCUIT BREAKERS. 3.MISCELLANEOUS: PROVIDE AND INSTALL: 3.1.(23) STANDARD BOLLARDS. 3.2.(8) REMOVABLE BOLLARDS. 3.3.(10) EV CHARGING ONLY STENCILS. 12" LETTERING. PAINTED WHITE. 3.4.(9) EV PARKING - ONLY WHILE CHARGING SIGN. 3.5.(1) EV PARKING - ONLY WHILE CHARGING SIGN WITH ISA. 3.6.(1) NO PARKING STENCIL. 12" LETTERING. PAINTED WHITE. 3.7.PAINTED PARKING DIVIDER LINES. 3.8.XYLOSMA CONGESTRUM. LANDSCAPING SCREENING FOR ALL MECHANICAL EQUIPMENT ASIDE FROM THE CHARGING STATIONS PER CITY REQUIREMENT. TABLE OF CONTENTS ·COVER PAGE ·SITE PLAN ·EV LAYOUT ·SCE LAYOUT ·SINGLE LINE DIAGRAM (SLD) ·DATA SHEETS ·REF-SIGNS & STENCILS ·REF-STRUCTURAL ·REF-TRENCHING & LANDSCAPING ·REF - ACCESSIBLE REACH REVISIONS DESCRIPTION DATE REV AHJ CORRECTION A 10/17/2025 A A VICINITY MAP CLARK LONGHURST, PRESIDENT, C&I DIV. SITELOGIQ, INC. LICENSE NO. 1054171 C-10 ELECTRICAL PE R M I T A P P L I C A T I O N THE DRAWING AND THE DESIGN SHOWN IS PROPERTY OF SITELOGIQ, INC. THE REPRODUCTION, COPYING, OR USE OF THIS DRAWING WITHOUT WRITTEN CONSENT OF SITELOGIQ IS PROHIBITED. ANY INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION. EVCS DESIGN DOCUMENTS DRAWN BY: CHECKED BY: DATE: REVISION: SHEET: TEMPLATE:5.14.2025 SU N F L O W E R M E T R O 39 4 1 S O U T H B R I S T O L S T R E E T , SA N T A A N A , C A 9 2 7 0 4 EL ANP 10.24.2025 A COMIND009300_42020_RENEWABLE ENERGY PARTNERS_SUNFLOWER METRO SANTA ANA_EV_REV A.DWG BUILDING DATA ·APN: 410-301-49 ·OCCUPANCY CLASS: B ·LEGAL DESCRIPTION: P BK 41 PG 6 PAR 2 PM 41-6 POR OF PAR 2 GENERAL NOTES 1. THIS PROJECT WILL COMPLY WITH THE FOLLOWING BUILDING CODES AND ASSOCIATED CITY OF SANTA ANA AMENDMENTS. 1.1.2022 CALIFORNIA BUILDING CODE (CBC) AND/OR CALIFORNIA RESIDENTIAL CODE (CRC) 1.2.2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN) 1.3.2022 CALIFORNIA ELECTRICAL CODE (CEC) 1.4.2022 CALIFORNIA MECHANICAL CODE (CMC) 1.5.2022 CALIFORNIA PLUMBING CODE (CPC) 1.6.2022 CALIFORNIA FIRE CODE (CFC) 1.7.2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS (CBEES) . 2. ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED OR CERTIFIED BY A NATIONALLY RECOGNIZED LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL HEALTH ADMINISTRATION (OSHA). 3 ALL ASSOCIATED ELECTRICAL EQUIPMENT ARC FLASH WARNING SHALL COMPLY WITH NEC ARTICLE 110.16 AND AVAILABLE FAULT CURRENT MARKING SHALL COMPLY WITH NEC ARTICLE 110.24. 4 A WRITTEN TEST RECORD SHALL BE PROVIDED TO THE CITY INSPECTOR PRIOR TO APPROVAL AND METER RELEASE PER CEC 230.95. 5 SERVICE ADDRESS TO BE VERIFIED WITH CITY PLANNING PRIOR TO METER RELEASE. A A SUNFLOWER AVE SUNFLOWER AVE SUNFLOWER AVE S B R I S T O L S T S B R I S T O L S T SUNFLOWER AVE BUILDING B BUILDING A BUILDING C PROPERTY LINE PROPERTY LINE S B R I S T O L S T PA R K C E N T E R D R PA R K C E N T E R D R S B R I S T O L S T S B R I S T O L S T S B R I S T O L S T AC C E S S R O A D SITE PLAN E-02SCALE: SITE PLAN 1" - 30'-0" KEY NOTES: [#] 1.(E) BUILDING. 2.(E) SIDEWALK. 3.(E) LANDSCAPE. 4.(E) 8' -6" STANDARD EV CHARGING STALLS. 5.(N) 12'-0" VAN ACCESSIBLE EV CHARGING STALL. (E) MAX. SLOPE OF 2% IN ALL DIRECTIONS. 6.(E) ACCESS AISLE. 7.(N) ACCESS AISLE. 8.(N) 5'-0" (MIN) PATH OF TRAVEL. (E) MAX. RUNNING SLOPE OF 5%. MAX. CROSS SLOPE OF 2%. 9.(E) UTILITY TRANSFORMER. 10.(N) UTILITY TRANSFORMER. 11.(N) MSB. REFER TO SINGLE LINE DIAGRAM (SLD) SHEET [E-05] FOR ADDITIONAL INFORMATION. 12.(E) UTILITY VAULT 13.(E) UTILITY PRIMARY RUN 14.(N) LOOP INFINITY FLASH 300KW POWER CABINETS. REFER TO SINGLE LINE DIAGRAM (SLD) SHEET [E-05] FOR ADDITIONAL INFORMATION. SITELOGIQ, INC SCOPE OF WORK AREA. SEE SHEET NO. E-03. 4 1 1 1 2 2 2 2 2 2 2 2 1 3 3 3 333 33 3 3 3 3 3 4 4 4 4 4 4 4 5 6 8 7 9 10 11 1 1 4 3 3 3 3 3 3 3 3 33 2 2 2 2 2 2 2 2 2 21 1 12 2 3 13 3 SCE UTILITY SCOPE OF WORK AREA. SEE SHEET NO. E-04. 3 3 3 PE R M I T A P P L I C A T I O N THE DRAWING AND THE DESIGN SHOWN IS PROPERTY OF SITELOGIQ, INC. THE REPRODUCTION, COPYING, OR USE OF THIS DRAWING WITHOUT WRITTEN CONSENT OF SITELOGIQ IS PROHIBITED. ANY INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION. EVCS DESIGN DOCUMENTS DRAWN BY: CHECKED BY: DATE: REVISION: SHEET: TEMPLATE:5.14.2025 SU N F L O W E R M E T R O 39 4 1 S O U T H B R I S T O L S T R E E T , SA N T A A N A , C A 9 2 7 0 4 EL ANP 10.24.2025 A COMIND009300_42020_RENEWABLE ENERGY PARTNERS_SUNFLOWER METRO SANTA ANA_EV_REV A.DWG 14 14 CLARK LONGHURST, PRESIDENT, C&I DIV. SITELOGIQ, INC. LICENSE NO. 1054171 C-10 ELECTRICAL 8'-6"8'-6"8'-6"8'-6"8'-6"8'-6"8'-6"8'-6" 8'-6"8'-6" 18'-0" 18'-0" 12'-0"5'-0"29'-3" EV CHARGING ONLY EV CHARGING ONLY EV CHARGING ONLY EV CHARGING ONLY EV CHARGING ONLY EV CHARGING ONLY EV CHARGING ONLY EV CHARGING ONLY EV CHARGING ONLY NO PARKING EV CHARGING ONLY 4'-0" NO PARKING 4'-0" 4'-0" 21'-1" 15'-7" 1'-8"1'-8" 3'-7" 3'-7" EV LAYOUT E-03SCALE: EV LAYOUT 1/8" = 1'-0" KEY NOTES: [#] 1.(N) LOOP INFINITY FLASH 300KW DUAL PORT PEDESTAL MOUNTED CHARGING STATIONS. 2.(N) LOOP INFINITY FLASH 300KW POWER CABINETS. 3.(N) STANDARD BOLLARDS. SEE SHEET [E-07] FOR DETAILS. 4.(N) EV CHARGING ONLY STENCILS. 12" LETTERING. PAINTED WHITE. 5.(N) EV PARKING - ONLY WHILE CHARGING SIGNS. SEE SHEET [E-07] FOR DETAILS 6.(N) 8' -6" STANDARD EV CHARGING STALLS. DOUBLE STRIPPED PER CITY REQUIREMENTS. 7.(N) PAINTED PARKING DIVIDER LINES. 8.(N) 12'-0" VAN ACCESSIBLE EV CHARGING STALL. (E) MAX. SLOPE OF 2% IN ALL DIRECTIONS. 9.NOT USED. 10.(N) STANDARD ACCESSIBILITY STALL. (E) SLOPE OF 2% IN ALL DIRECTIONS. 11.(N) ACCESS AISLE. (E) MAX. SLOPE OF 2% IN ALL DIRECTIONS. PAINTED WHITE. 12.(N) NO PARKING STENCIL. 12" LETTERING. PAINTED WHITE. 13.(N) 5'-0" (MIN) PATH OF TRAVEL. (E) MAX. RUNNING SLOPE OF 5%. MAX. CROSS SLOPE OF 2%. 14.(E) UTILITY TRANSFORMER. 15.(N) UTILITY TRANSFORMER. 16.(N) MSB. REFER TO SINGLE LINE DIAGRAM (SLD) SHEET [E-05] FOR ADDITIONAL INFORMATION. 17.(N) APPROXIMATE CONDUIT ROUTE. 18.(E) ACCESS AISLE. 19.(E) BUILDING. 20.(E) SIDEWALK. 21.(E) LANDSCAPE. 22.(N) EV PARKING - ONLY WHILE CHARGING SIGN WITH ISA. 23.(N) 30"X48" CHARGER OPERATION CLEAR SPACE. 24.(E) APPROXIMATE UTILITY CONDUIT ROUTE 25.(N) STANDARD REMOVABLE BOLLARDS. SEE SHEET [E-07] FOR DETAILS. 26.(N) POWER CABINET PAD 27.(N) LANDSCAPE SCREENING PER CITY REQUIREMENTS, SAME HEIGHT AS MECHANICAL EQUIPMENT. MAINTAINING ACCESS CLEARANCE. REFER TO SHEET [E-08]. SCALE: KEYPLAN NTS 1 1 1 1 1 2 2 3 3 33 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 67777777 7 77 7 10 8 5 11 11 12 13 14 15 16 17 18 19 19 19 20 20 20 20 21 21 21 21 21 21 21 21 22 23 24 PE R M I T A P P L I C A T I O N THE DRAWING AND THE DESIGN SHOWN IS PROPERTY OF SITELOGIQ, INC. THE REPRODUCTION, COPYING, OR USE OF THIS DRAWING WITHOUT WRITTEN CONSENT OF SITELOGIQ IS PROHIBITED. ANY INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION. EVCS DESIGN DOCUMENTS DRAWN BY: CHECKED BY: DATE: REVISION: SHEET: TEMPLATE:5.14.2025 SU N F L O W E R M E T R O 39 4 1 S O U T H B R I S T O L S T R E E T , SA N T A A N A , C A 9 2 7 0 4 EL ANP 10.24.2025 A COMIND009300_42020_RENEWABLE ENERGY PARTNERS_SUNFLOWER METRO SANTA ANA_EV_REV A.DWG 25 26 3 3 3 3 27 27 27 A A A CLARK LONGHURST, PRESIDENT, C&I DIV. SITELOGIQ, INC. LICENSE NO. 1054171 C-10 ELECTRICAL SUNFLOWER AVE AC C E S S R O A D SCE UTILITY LAYOUT E-04SCALE: SCE UTILITY LAYOUT 1/8" = 1'-0" KEY NOTES: [#] 1.(E) APPROXIMATE UTILITY CONDUIT ROUTE. 2.(E) UTILITY VAULT 3.(E) ACCESS AISLE. 4.(E) BUILDING. 5.(E) SIDEWALK. 6.(E) LANDSCAPE. SCALE: KEYPLAN NTS 1 5 6 6 6 6 55 5 5 5 5 4 4 6 6 5 5 3 3 3 3 3 2 PE R M I T A P P L I C A T I O N THE DRAWING AND THE DESIGN SHOWN IS PROPERTY OF SITELOGIQ, INC. THE REPRODUCTION, COPYING, OR USE OF THIS DRAWING WITHOUT WRITTEN CONSENT OF SITELOGIQ IS PROHIBITED. ANY INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION. EVCS DESIGN DOCUMENTS DRAWN BY: CHECKED BY: DATE: REVISION: SHEET: TEMPLATE:5.14.2025 SU N F L O W E R M E T R O 39 4 1 S O U T H B R I S T O L S T R E E T , SA N T A A N A , C A 9 2 7 0 4 EL ANP 10.24.2025 A COMIND009300_42020_RENEWABLE ENERGY PARTNERS_SUNFLOWER METRO SANTA ANA_EV_REV A.DWG CLARK LONGHURST, PRESIDENT, C&I DIV. SITELOGIQ, INC. LICENSE NO. 1054171 C-10 ELECTRICAL 95" 77" 18" 96" ONLY WHILE CHARGING ELECTRIC VEHICLE PARKING 12" 1" ABOVE GRADE 4" TYP. 2%2% TOP TO SLOPETOP TO SLOPE 3" MIN. BELOW GRADE EV CHARGING ONLY 4'-0" 4" 27" 3" 18" 6" MIN 3" 30" 4" SCALE: EV PARKING SIGN - ONLY WHILE CHARGING 1" = 1'-0" REFERENCE DRAWING (EV SIGNAGE) FRONT RIGHT 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.1 2.1 2.9 3.1 2.10 2.1 2.3 SCALE: STANDARD BOLLARD 1/8" = 1'-0"SCALE: EV SIGNAGE SECTION DETAIL 3" = 1'-0" SCALE: EV PARKING STENCILKEY NOTES: [#] 1.BOLLARDS: 1.1.GALVANIZED STEEL PIPE (1 4" MIN. WALL). 1.2.BLACK PLASTIC CAP. 1.3.4" HDG. PIPE X 60" LENGTH, 1 4 " WALL THICKNESS (SAP 10210917). 1.4.0.2 C.Y. CONCRETE, 4000 PSI @ 28 DAYS, TYPE 1 CEMENT. 1.5.FINISHED SURFACE. 1.6.5" HDG. PIPE SLEEVE (BASE) X 30" LENGTH 1 4 WALL THICKNESS. 1.7.MECHANICAL ANCHORS, PER SITE CONDITIONS. 1.8.CONCRETE ENCASEMENT, PER SITE CONDITIONS. 2.EV SIGNAGE: 2.1.1 3 4" PRE-DRILLED, GALVANIZED STEEL, SQUARE TUBE POST. 14 GAUGE. 7 16" HOLES ON 1" INTERVAL. 2.2.1 4" BRUSHED ALUMINUM BACKER PANEL. 2.3.SMARTSIGN 3M, REFLECTIVE, "ELECTRIC VEHICLE PARKING - ONLY WHILE CHARGING" GRAPHIC. 18" X 12". COLORS: GREEN & WHITE. NOTE: WALL MOUNTED SIGNS ARE ANCHORED DIRECTLY TO THE WALL. 2.4.STAINLESS STEEL COUNTERSUNK MECHANICAL FASTENERS WITH STAINLESS STEEL THREADED POST INSERTS. 2.5.SILICONE ADHESIVE. 2.6.CONCRETE FOOTING WITH MOW STRIP. TROWEL SMOOTH FINISH WITH ROUNDED EDGES. 2.7.SUB-GRADE CONCRETE FOOTING, PER SITE CONDITIONS. 2.8.SQUARE, SURFACE MOUNT, POST ANCHOR. 6" X 6" X 6". 2.9.MECHANICAL ANCHORS, PER SITE CONDITIONS. 2.10.EXISTING CONCRETE. 3.PARKING STENCIL 3.1.TRAFFIC ZONE MARKING PAINT (5GAL/BUCKET). GREEN OR WHITE TO CONTRAST SURFACE. 3.2.PARKING SPACE STRIPE(S) UTILIZE SAME GREEN OR WHITE PAINT AS EV STENCIL.E-07 PE R M I T A P P L I C A T I O N THE DRAWING AND THE DESIGN SHOWN IS PROPERTY OF SITELOGIQ, INC. THE REPRODUCTION, COPYING, OR USE OF THIS DRAWING WITHOUT WRITTEN CONSENT OF SITELOGIQ IS PROHIBITED. ANY INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION. EVCS DESIGN DOCUMENTS DRAWN BY: CHECKED BY: DATE: REVISION: SHEET: TEMPLATE:5.14.2025 SU N F L O W E R M E T R O 39 4 1 S O U T H B R I S T O L S T R E E T , SA N T A A N A , C A 9 2 7 0 4 EL ANP 10.24.2025 A COMIND009300_42020_RENEWABLE ENERGY PARTNERS_SUNFLOWER METRO SANTA ANA_EV_REV A.DWG SCALE: REMOVABLE BOLLARD 1/8" = 1'=0" 1.3 1.6 1.4 1.5 1.7 1.2 1.1 1.8 CLARK LONGHURST, PRESIDENT, C&I DIV. SITELOGIQ, INC. LICENSE NO. 1054171 C-10 ELECTRICAL REFERENCE DRAWING (STRUCTURAL) KEYNOTES: [#] 1.LOOP INFINITY FLASH POWER CABINET, CONCRETE FOUNDATION. PER MANUFACTURERS REQUIREMENTS. 2.LOOP INFINITY FLASH EV CHARGER, CONCRETE FOUNDATION. PER MANUFACTURERS REQUIREMENTS. E-08 PE R M I T A P P L I C A T I O N THE DRAWING AND THE DESIGN SHOWN IS PROPERTY OF SITELOGIQ, INC. THE REPRODUCTION, COPYING, OR USE OF THIS DRAWING WITHOUT WRITTEN CONSENT OF SITELOGIQ IS PROHIBITED. ANY INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION. EVCS DESIGN DOCUMENTS DRAWN BY: CHECKED BY: DATE: REVISION: SHEET: TEMPLATE:5.14.2025 SU N F L O W E R M E T R O 39 4 1 S O U T H B R I S T O L S T R E E T , SA N T A A N A , C A 9 2 7 0 4 EL ANP 10.24.2025 A COMIND009300_42020_RENEWABLE ENERGY PARTNERS_SUNFLOWER METRO SANTA ANA_EV_REV A.DWG 1 2 CLARK LONGHURST, PRESIDENT, C&I DIV. SITELOGIQ, INC. LICENSE NO. 1054171 C-10 ELECTRICAL 48" MAX34" MAX 10" MAX 46" MAX34" MAX 10"-24" MAX 15" MIN 48" MAX 10" MAX 9" 6" MAX 30" 48" 30" 48" 30" 48" 15" MIN 48" MAX REFERENCE DRAWING (REACH HEIGHT) SCALE: ACCESSIBLE CHARGER REACH HEIGHTS 1" = 1'-0" KEY NOTES: [#] 1.ACCESSIBLE EV CHARGERS: MOUNTING HEIGHT SHALL COMPLIED WITH 2022 CEC 625.5 (24" MIN. A.F.F) AND (2022 CBC 11B-309 48" MAX. A.F.F.) 2.NON-ACCESSIBLE EV CHARGERS: MOUNTING HEIGHT SHALL COMPLIED WITH 2022 (CEC 625.5 24" MIN. A.F.F.) E-09 PE R M I T A P P L I C A T I O N THE DRAWING AND THE DESIGN SHOWN IS PROPERTY OF SITELOGIQ, INC. THE REPRODUCTION, COPYING, OR USE OF THIS DRAWING WITHOUT WRITTEN CONSENT OF SITELOGIQ IS PROHIBITED. ANY INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION. EVCS DESIGN DOCUMENTS DRAWN BY: CHECKED BY: DATE: REVISION: SHEET: TEMPLATE:5.14.2025 SU N F L O W E R M E T R O 39 4 1 S O U T H B R I S T O L S T R E E T , SA N T A A N A , C A 9 2 7 0 4 EL ANP 7.24.2025 COMIND009300_42020_RENEWABLE ENERGY PARTNERS_SUNFLOWER METRO SANTA ANA_EV.DWG CLARK LONGHURST, PRESIDENT, C&I DIV. SITELOGIQ, INC. LICENSE NO. 1054171 C-10 ELECTRICAL 48" MAX34" MAX 10" MAX 46" MAX34" MAX 10"-24" MAX 15" MIN 48" MAX 10" MAX 9" 6" MAX 30" 48" 30" 48" 30" 48" 15" MIN 48" MAX REFERENCE DRAWING (REACH HEIGHT) SCALE: ACCESSIBLE CHARGER REACH HEIGHTS 1" = 1'-0" KEY NOTES: [#] 1.ACCESSIBLE EV CHARGERS: MOUNTING HEIGHT SHALL COMPLY WITH 2022 CEC 625.5 (24" MIN. A.F.F) AND (2022 CBC 11B-309 48" MAX. A.F.F.) 2.NON-ACCESSIBLE EV CHARGERS: MOUNTING HEIGHT SHALL COMPLY WITH 2022 (CEC 625.5 24" MIN. A.F.F.) E-10 PE R M I T A P P L I C A T I O N THE DRAWING AND THE DESIGN SHOWN IS PROPERTY OF SITELOGIQ, INC. THE REPRODUCTION, COPYING, OR USE OF THIS DRAWING WITHOUT WRITTEN CONSENT OF SITELOGIQ IS PROHIBITED. ANY INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION. EVCS DESIGN DOCUMENTS DRAWN BY: CHECKED BY: DATE: REVISION: SHEET: TEMPLATE:5.14.2025 SU N F L O W E R M E T R O 39 4 1 S O U T H B R I S T O L S T R E E T , SA N T A A N A , C A 9 2 7 0 4 EL ANP 10.24.2025 A COMIND009300_42020_RENEWABLE ENERGY PARTNERS_SUNFLOWER METRO SANTA ANA_EV_REV A.DWG CLARK LONGHURST, PRESIDENT, C&I DIV. SITELOGIQ, INC. LICENSE NO. 1054171 C-10 ELECTRICAL T GND A (N) UTILITY TRANSFORMER (N) MSB: 3000A, 480/277V, 3PH, 4W, 65kAIC NEMA 3R PLAN NOTES: 1.ALL OCPD SHALL BE LOCKED OUT IN AN OPEN POSITION. 2.MAIN CIRCUIT BREAKER TO BE PROVIDED WITH GROUND-FAULT PROTECTION OF EQUIPMENT AND SHALL BE PERFORMANCE TESTED PRIOR TO ENERGIZATION VIA THE PRIMARY CURRENT INJECTION PROCCESS. A WRITTEN TEST RECORD SHALL BE PROVIDED TO THE CITY INSPECTOR PRIOR TO APPROVAL AND METER RELEASE PER CEC 230.95. 3.SERVICE ADDRESS TO BE VERIFIED WITH CITY PLANNING PRIOR TO METER RELEASE. NEW EXISTING LEGEND 1 NUMBER OF CHARGING UNITS:5 NUMBER OF PORTS:10 ELECTRICAL RATING PER POWER CABINET:LEVEL 3: 433A, 480V MAXIMUM CAPACITY PER PORT (DC):300KW MAX (150KW EACH IF SHARED) LOAD SHARING:YES 2 ELECTRICAL PANEL RATING:(N) MSB: 3000A, 480/277V, 3PH, 4W, 65kAIC NEMA 3R ENCLOSURE (N) SERVICE METERM (N) 3000A/3P 2 (N) (2) 5/8" x 8'-0" COPPER CLAD GROUND ROD INSTALLATION PER NEC 250-62, 250-64, AND 250-68 (2) #1/0 BARE COPPER GROUNDING ELECTRODE CONDUCTOR PER NEC 250-66(A) 6'-0" MIN. (N) EVCS #1 DUAL PORT LOOP INFINITY (N) EVCS #2 DUAL PORT LOOP INFINITY (N) EVCS #3 DUAL PORT LOOP INFINITY (N) EVCS #4 DUAL PORT LOOP INFINITY B B (N) 600A/3P (N) POWER CABINET 1 (N) POWER CABINET 2 C C (N) 600A/3P B (N) 600A/3P (N) POWER CABINET 3 C B (N) 600A/3P (N) POWER CABINET 4 C 1 1 1 1 (N) EVCS #5 DUAL PORT LOOP INFINITY B (N) 600A/3P (N) POWER CABINET 5 C 1 3 SINGLE LINE DIAGRAM E-05 PE R M I T A P P L I C A T I O N THE DRAWING AND THE DESIGN SHOWN IS PROPERTY OF SITELOGIQ, INC. THE REPRODUCTION, COPYING, OR USE OF THIS DRAWING WITHOUT WRITTEN CONSENT OF SITELOGIQ IS PROHIBITED. ANY INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION. EVCS DESIGN DOCUMENTS DRAWN BY: CHECKED BY: DATE: REVISION: SHEET: TEMPLATE:5.14.2025 SU N F L O W E R M E T R O 39 4 1 S O U T H B R I S T O L S T R E E T , SA N T A A N A , C A 9 2 7 0 4 EL ANP 10.24.2025 A COMIND009300_42020_RENEWABLE ENERGY PARTNERS_SUNFLOWER METRO SANTA ANA_EV_REV A.DWG A CLARK LONGHURST, PRESIDENT, C&I DIV. SITELOGIQ, INC. LICENSE NO. 1054171 C-10 ELECTRICAL DATA SHEETS E-06 PE R M I T A P P L I C A T I O N THE DRAWING AND THE DESIGN SHOWN IS PROPERTY OF SITELOGIQ, INC. THE REPRODUCTION, COPYING, OR USE OF THIS DRAWING WITHOUT WRITTEN CONSENT OF SITELOGIQ IS PROHIBITED. ANY INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION. EVCS DESIGN DOCUMENTS DRAWN BY: CHECKED BY: DATE: REVISION: SHEET: TEMPLATE:5.14.2025 SU N F L O W E R M E T R O 39 4 1 S O U T H B R I S T O L S T R E E T , SA N T A A N A , C A 9 2 7 0 4 EL ANP 10.24.2025 A COMIND009300_42020_RENEWABLE ENERGY PARTNERS_SUNFLOWER METRO SANTA ANA_EV_REV A.DWG CLARK LONGHURST, PRESIDENT, C&I DIV. SITELOGIQ, INC. LICENSE NO. 1054171 C-10 ELECTRICAL YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 3941 S Bristol St, 4 EV Charging 4 4 4 4 4 4 4 4 4 Kristina Losorelli 760 780-6059 08 15 2025 Santa Ana KL KL O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs