Loading...
HomeMy WebLinkAbout2010 E First St Units #200 & 210 - REV 1 - PlanS O V O V S S S S S S OVVVOVVVOVVV 19 TYP. 5 TYP. 6 TYP. 4 8 TYP. 11 15 182081119415 13 TYP. 18 13 TYP. 9 TYP. 191071 7 1 20 20 7 16 10 24 20 1413 5 107 6 5 19 18 20 TYP. TYP. TYP. TYP. TYP.TYP.TYP.TYP.TYP. 23 23 1 9 TYP. TYP. TYP. TYP. 19 4 2 2 3 3 3 3 3 3 33 3 3 3 3 3 3 3 1 2 3 3 2 3 9 TYP.18 20 3 3 3 3 2 25 24 10 24 18 20 26 10 3 27 15 15 13 14 A-2.0 SHEET NO. 2402 REVISIONS: 4/12/2024DATE: PROJECT NO. PERMIT NO. Dr . B e s h a i A S C 20 1 0 E . 1 s t S t r e e t , S t e . 2 0 0 & 2 1 0 , S a n t a A n a , C A 9 2 7 0 5 Ne w A m b u l a t o r y C a r e F a c i l i t y T e n a n t I m p r o v e m e n t 10/31/25 REN. DATE C-26955 OIF NRI LOFCA SAUNDERS TATS E CETIHCADESRCILEN NIALL F. A T 1/4" = 1'-0" REFLECTED CEILING PLAN 2.0 A N REFLECTED CEILING PLAN CEILING PLAN KEYNOTES 1.COORDINATE REFLECTED CEILING INSTALLATION WITH MECHANICAL AND ELECTRICAL REQUIREMENTS - SEE E-SERIES & M-SERIES DWGS. VERIFY ALL HVAC DIFUSER LOCATIONS IN FIELD. 2. CEILINGS INDICATED AS GYP. BD. TO BE 5/8" TYPE 'X' WITH SMOOTH WASHABLE PAINTED FINISH. ATTACHED GYPSUM BOARD TO MTL. STUD JOISTS AT 16" O.C. STUD JOISTS TO SPAN SHORTEST DIST. BETWEEN ADJ. WALLS IN EA. CASE. 3. INTERIOR CEILING HEIGHTS VARY - SEE SHEET NOTE ABOVE, AND FINISH SCHEDULE. 4. DO NOT SCALE FROM PLANS. FIELD VERIFY ALL DIMENSIONS & REPORT ANY DISCREPANCIES TO ARCHITECT AT ONCE. 5.EXIT SIGNS TO BE INTERNALLY ILLUM. AND PROVIDED W/ BATTERY BACK-UP OF MIN. 1 -1/2 HOURS DURATION IN CASE OF PRIMARY POWER LOSS. 6.PROVIDE MIN. 1 FOOT-CANDLE ILLUM. IN ALL OCCUPIED AREAS OF THE BUILDING AND EGRESS ROUTES. GENERAL NOTES 1.NEW SUSPENDED T-BAR CEILING SYSTEM: ARMSTRONG SEISMIC RX HEAVY DUTY - SUPRAFINE XL 7500 9/16" TEESERIES W/24"x24" (SEE PLAN) ASTRO-CLIMA ACOUSTIC LAY-IN TILES.OR SELECTED BY OWNER - SEE DETAILS. 2.NEW GYP. BD. CEILING W/ SMOOTH TEXTURE FINISH: GYP. BD. CEILING: 5/8" TYPE 'X' GYPSUM BOARD ON 2X 20 GA. MTL. JOIST STUDS 16" O.C. W/ BLK'G. / BRACING AS - CEILING HEIGHTS AS NOTED BELOW. SEMIGLOSS SHEEN WASHABLE PAINT. 3.NEW 5" LED DOWNLIGHT - TYP. - SEE ELEC. 4.NEW EDGE-ILLUM. EXIT SIGN (EXIT DOORWAYS, ETC.). PROVIDE UNIT W/ 90 MINUTE BATTERY BACK-UP - SEE ELEC. 5.2'x2' HVAC REGISTER / RTN. - SEE MECH. SCHEDULE 6.2'x2'/4' FLUSH PANEL LED LIGHT FIXTURES - SEE ELEC. FIXTURE SCHEDULE 7.3" TRIMLESS LED DOWNLIGHT - LITHONIA OR EQ. 8.NEW 30" DIA. DECORATIVE LED CHANDELIER (AS PROVIDED BY OWNER) - COORD. W/ ELEC. - ALL PENDANT FIXTURES TO BE HUNG PER MANUF. DIRECTIONS. 9.PROVIDE 4" SOUND INSULATION BLANKETS OVER THE TOP OF WALLS - TYP. ALL WALLS OF EXAM RMS. 10.CONNECT TO EXHAUST DUCT VENTED TO EXTERIOR. 11.NEW GYP. BD. SOFFIT W/ 3" LED DOWNLIGHTING. 12.LINEAR SLOT DIFFUSER - THIS LOCATION ONLY. 13.50 KVA ELEC. TRANSFORMER LOCN. - SEE STRUCT. SUPPORT DETAIL BELOW - ACCESS VIA ADJ. SUSPENDED CLG. TILES 14.75 KVA ELEC. TRANSFORMER LOCN. - SEE STRUCT. SUPPORT DETAIL BELOW - ACCESS VIA ADJ. SUSPENDED CLG. TILES ACCESS PANEL: FOR CEILING ACCESS PANEL SEE 0A7.0 FOR ROOF HATCH SEE 0A7.0 MECHANICAL REGISTERS: REFER TO MECHANICAL DRAWINGS FOR FIXTURE TYPES LIGHT FIXTURES ETC. (REFER TO ELECTRICAL DWGS: ILLUMINATED EXIT SIGNS (W/ 90 MIN. BATTERY BACKUP) 2'X4' RECESSED LED PARABOLIC 2'X4' FLAT PANEL LED LIGHT 2'X4' RECESSED LED W/ PLASTIC PRISMATIC LENS (SEALED CLEAN ROOM FIXTURES IN OP ROOMS) RECESSED LED DOWNLIGHT (W/ LENS IN OP ROOM) LED UNDER-CABINET TASK LIGHT (ALKO OR EQ.) CEILING SPEAKERS (W/ SEP. VOL. CONTROL) LED WALL SCONCE / VANITY LIGHT AT 84" AFF CONCEALED LED LED TAPE LIGHT - CONTINUOUS CEILING LEGEND NOTE: ELECTRICALLY POWERED, SELF-LUMINOUS AND PHOTO LUMINESCENT EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND CHAPTER 27. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. CBC 1011.4 CEILING HEIGHTS CEILING ACCESSORIES (REFER TO ELECTRICAL DRAWINGS) CEILING SPEAKERS (W/ SEPARATE VOLUME CONTROL) CABLE TV OUTLET NURSE CALL LIGHT DRYWALL CEILING ACCESS HATCH (GASKETTED AT STERILE ROOMS)H SP TV SP 2 9'-0" ALL CEILING HEIGHTS SUBJECT TO FIELD VERIFICATION 3 10'-0" 1 7'-0" 6 A6.0 7 A6.0 6 A6.0 7 A6.0 4 A6.2 4 A6.2 8 A6.0 8 A6.0 4 A6.0 12 A6.0 9 A6.2 5 A6.2 8 A6.2 8 A6.2 A BUILDING REVIEW REVISIONS 11-21-24 B FIELD REVISIONS 2-12-25