HomeMy WebLinkAbout2010 E First St Units #200 & 210 - REV 1 - PlanS
O
V
O
V
S
S
S
S
S
S
OVVVOVVVOVVV
19 TYP.
5 TYP.
6 TYP.
4
8 TYP.
11
15
182081119415
13 TYP.
18
13 TYP.
9 TYP.
191071
7
1
20
20
7
16
10
24
20
1413
5
107
6
5
19
18
20
TYP.
TYP.
TYP.
TYP.
TYP.TYP.TYP.TYP.TYP.
23
23
1
9
TYP.
TYP.
TYP.
TYP.
19
4
2
2
3
3
3 3
3
3
33
3
3 3
3
3
3
3
1
2
3
3
2
3
9 TYP.18
20
3
3
3
3
2
25
24
10
24
18
20
26
10
3
27
15
15
13
14
A-2.0
SHEET NO.
2402
REVISIONS:
4/12/2024DATE:
PROJECT NO.
PERMIT NO.
Dr
.
B
e
s
h
a
i
A
S
C
20
1
0
E
.
1
s
t
S
t
r
e
e
t
,
S
t
e
.
2
0
0
&
2
1
0
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
5
Ne
w
A
m
b
u
l
a
t
o
r
y
C
a
r
e
F
a
c
i
l
i
t
y
T
e
n
a
n
t
I
m
p
r
o
v
e
m
e
n
t
10/31/25
REN. DATE
C-26955
OIF
NRI
LOFCA
SAUNDERS
TATS
E
CETIHCADESRCILEN
NIALL F.
A
T
1/4" = 1'-0"
REFLECTED CEILING PLAN
2.0
A
N
REFLECTED
CEILING PLAN
CEILING PLAN KEYNOTES
1.COORDINATE REFLECTED CEILING INSTALLATION WITH MECHANICAL AND ELECTRICAL REQUIREMENTS - SEE E-SERIES &
M-SERIES DWGS. VERIFY ALL HVAC DIFUSER LOCATIONS IN FIELD.
2. CEILINGS INDICATED AS GYP. BD. TO BE 5/8" TYPE 'X' WITH SMOOTH WASHABLE PAINTED FINISH. ATTACHED GYPSUM
BOARD TO MTL. STUD JOISTS AT 16" O.C. STUD JOISTS TO SPAN SHORTEST DIST. BETWEEN ADJ. WALLS IN EA. CASE.
3. INTERIOR CEILING HEIGHTS VARY - SEE SHEET NOTE ABOVE, AND FINISH SCHEDULE.
4. DO NOT SCALE FROM PLANS. FIELD VERIFY ALL DIMENSIONS & REPORT ANY DISCREPANCIES TO ARCHITECT AT ONCE.
5.EXIT SIGNS TO BE INTERNALLY ILLUM. AND PROVIDED W/ BATTERY BACK-UP OF MIN. 1 -1/2 HOURS DURATION IN CASE OF
PRIMARY POWER LOSS.
6.PROVIDE MIN. 1 FOOT-CANDLE ILLUM. IN ALL OCCUPIED AREAS OF THE BUILDING AND EGRESS ROUTES.
GENERAL NOTES
1.NEW SUSPENDED T-BAR CEILING SYSTEM: ARMSTRONG SEISMIC RX HEAVY DUTY - SUPRAFINE XL 7500 9/16" TEESERIES
W/24"x24" (SEE PLAN) ASTRO-CLIMA ACOUSTIC LAY-IN TILES.OR SELECTED BY OWNER - SEE DETAILS.
2.NEW GYP. BD. CEILING W/ SMOOTH TEXTURE FINISH: GYP. BD. CEILING: 5/8" TYPE 'X' GYPSUM BOARD ON 2X 20 GA.
MTL. JOIST STUDS 16" O.C. W/ BLK'G. / BRACING AS - CEILING HEIGHTS AS NOTED BELOW. SEMIGLOSS SHEEN
WASHABLE PAINT.
3.NEW 5" LED DOWNLIGHT - TYP. - SEE ELEC.
4.NEW EDGE-ILLUM. EXIT SIGN (EXIT DOORWAYS, ETC.). PROVIDE UNIT W/ 90 MINUTE BATTERY BACK-UP - SEE ELEC.
5.2'x2' HVAC REGISTER / RTN. - SEE MECH. SCHEDULE
6.2'x2'/4' FLUSH PANEL LED LIGHT FIXTURES - SEE ELEC. FIXTURE SCHEDULE
7.3" TRIMLESS LED DOWNLIGHT - LITHONIA OR EQ.
8.NEW 30" DIA. DECORATIVE LED CHANDELIER (AS PROVIDED BY OWNER) - COORD. W/ ELEC. - ALL PENDANT FIXTURES
TO BE HUNG PER MANUF. DIRECTIONS.
9.PROVIDE 4" SOUND INSULATION BLANKETS OVER THE TOP OF WALLS - TYP. ALL WALLS OF EXAM RMS.
10.CONNECT TO EXHAUST DUCT VENTED TO EXTERIOR.
11.NEW GYP. BD. SOFFIT W/ 3" LED DOWNLIGHTING.
12.LINEAR SLOT DIFFUSER - THIS LOCATION ONLY.
13.50 KVA ELEC. TRANSFORMER LOCN. - SEE STRUCT. SUPPORT DETAIL BELOW - ACCESS VIA ADJ. SUSPENDED CLG. TILES
14.75 KVA ELEC. TRANSFORMER LOCN. - SEE STRUCT. SUPPORT DETAIL BELOW - ACCESS VIA ADJ. SUSPENDED CLG. TILES
ACCESS PANEL:
FOR CEILING ACCESS PANEL SEE 0A7.0
FOR ROOF HATCH SEE 0A7.0
MECHANICAL REGISTERS:
REFER TO MECHANICAL DRAWINGS FOR FIXTURE TYPES
LIGHT FIXTURES ETC. (REFER TO ELECTRICAL DWGS:
ILLUMINATED EXIT SIGNS (W/ 90 MIN. BATTERY BACKUP)
2'X4' RECESSED LED PARABOLIC
2'X4' FLAT PANEL LED LIGHT
2'X4' RECESSED LED W/ PLASTIC PRISMATIC LENS
(SEALED CLEAN ROOM FIXTURES IN OP ROOMS)
RECESSED LED DOWNLIGHT (W/ LENS IN OP ROOM)
LED UNDER-CABINET TASK LIGHT (ALKO OR EQ.)
CEILING SPEAKERS (W/ SEP. VOL. CONTROL)
LED WALL SCONCE / VANITY LIGHT AT 84" AFF
CONCEALED LED LED TAPE LIGHT - CONTINUOUS
CEILING LEGEND
NOTE:
ELECTRICALLY POWERED, SELF-LUMINOUS AND
PHOTO LUMINESCENT EXIT SIGNS SHALL BE
LISTED AND LABELED IN ACCORDANCE WITH UL
924 AND SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURERS INSTRUCTIONS AND
CHAPTER 27. EXIT SIGNS SHALL BE ILLUMINATED
AT ALL TIMES. CBC 1011.4
CEILING HEIGHTS
CEILING ACCESSORIES
(REFER TO ELECTRICAL DRAWINGS)
CEILING SPEAKERS
(W/ SEPARATE VOLUME CONTROL)
CABLE TV OUTLET
NURSE CALL LIGHT
DRYWALL CEILING ACCESS HATCH
(GASKETTED AT STERILE ROOMS)H
SP
TV
SP
2 9'-0"
ALL CEILING HEIGHTS SUBJECT TO FIELD VERIFICATION
3 10'-0"
1 7'-0"
6
A6.0
7
A6.0
6
A6.0
7
A6.0
4
A6.2
4
A6.2
8
A6.0
8
A6.0
4
A6.0
12
A6.0
9
A6.2
5
A6.2
8
A6.2
8
A6.2
A BUILDING REVIEW
REVISIONS 11-21-24
B FIELD REVISIONS
2-12-25