HomeMy WebLinkAbout20164262 - PermitCity of Santa Ana
Permit Counter: (714) 647-5800
20 Civic Center Plaza (M-19), Santa Ana, CA 92702 Electrical Permit #: 2(,16,426,2
Pin #: 62135lnspection Requests: (7'14) 667-2738 lnspector Section: (714) 647-5853
Project Address: 410 S Diamond St Bldg:
Tract: 4659
Address Range:
Historic: No
Suite Range:
Zoning; R1
W
Assessor'sParcel: 0'10-011-'17 Lot.50
Owner:
Address
Ling Nguyen
410 S. Oiamond Street
Santa Ana, CA 92703
(714) 510-5293
Fee Type Amount Qt)Fee
Phone
Tenant Name
Contractor
Address:
Thomas lnternational Comp
PO Box 877
Midway City, CA 92555
(7r4) 5r0.5293Phone
State Lic #: 876125
Lic Type: A, C-10
Bus. Lic #: 367085
Workers' Compensation lnsuranceCarrier: Exempt
Policy #:
Expires;
Building Use:
Job Type:
Nature of Work
Single Family Dwelling
Solar
Solar
Occupancy;
Constr Type
Code:
R-3, U
VB
cEc 2016 Notes: lnstall new 5.2 kw solar PV system. (18 panels) ALL
FEES PA|O ON 10194293.
Planning Conditions
Planning Approval By
Plan Checked By:
Permit lssued By:
Subject to Field:
Zuniga, Allissa
Date
Date
Date 09t26t2017
Account#
Misc. Receipl:
Misc. Receipt:
Misc. Receipt;
Total
Buildins Permit #: 10194293
Every permil issued sha becorne invalid unless lhe wo* on the site
authonzed by such pe/mit is commenced wtthin180 days aftet its
6suance, ot it the wo* authonzed on lhe site by such permit is suspondod
ot abandon1d for a poiod of 180 days aftet the line lhe work is
commenced
$0 00
$0 00
s0.00
lnspector MID#: 2017-138916
Fee Total:
Paid to Date:
Balance Due:
U nit:
Block; NA
ELECTRICAL.INSPECTOR RECORD
APPROVALS DATE tD/stG.COMMENTS l)$Nt R rl ll.Dl k lrtl.r AR l I ll,N
tltEbyrrmunLrF !y ol Frrry lh, I o cr.qi rDh rlx CrdtutE LIBE l,w ror rtr folheh! Erc,n (S(
'0.!l5au!6i ml PmL$nn CoL) An, Cdy d Cotly *hrh EquBr . FL lo 6d.d rld. utFtrw. &fr,uh '. q.r ev
(turuE. F$r ro 'rt 8rurru, .tqr G&rt i,t {,pta6r t skh Fmr ro rik r rBEd (.l.ffir thrl lE m.lr u lEnhl nortid
b rlE Flvni'nr 6f rh. Conktld r Li€ns{ llw (Cnttr.r 9. cl'mftEii8 w h s.cl!'n 7000 or r,ivirb. I r th. Bnun's lnJ
Pmf.$br. cuL) or rh.r h.q nr !r.r.,!i rlEEfiom "n E b't! tu rlr rlks'rl 'rcq nn Anv lFhrD"I sai i" Tol I lbvrv
.t!'lErt rr, r IEmn rubj.tk rlr qi0hsr l. r Liv FMhyofmi mrc th.. rrk h!nl,6r !b[.r. (t100].
l.rr o*mrolrt rn)Fny, tx my.rnt,rt tw h wrtcl.r rrEt.t.amFno.n w ld.rlEw'rr.,n[rrdtu6n
d.rH * ofl.r.d ld rl {Sd 70L, Buitrii.ri Prn$onr CrL: Irr C.tudir'r lro* tr} drEt mr +il, to o.vEr oi
rlx F.FnPtn bxth d flF,s ttEsa lrl $'lb dftr uh kfi hrNlf or h.Elr or llnulh hn q t*, ow. .mPlor..r.
t'iovdat rh.r rurh imlrnErft e mr id.nldl or.fi.En lrtr ek li krw. rlE ttriLluS.r in+6rwmd t {'! *irhin.ft ,t{
ofd,l!*L[ rlE OvF. Burlls *dl ,I,E tlE tw,Ln of F'ri4lh.r lrddxdd ril t! ! n lqrDt rlr FFiv lu rlE F{r( or
-1.
a! owRr or rlF F't'.dy, !m .r.lurv.ly conlrsrDs *'lh I'ccn\.d cont&roF lo .rn$tu1 ltr ln Ft (Scc 7044. Burift(
.!, hDa(rn GxL TlE codr&lr't Li..n( 1,,.h! n +!ly b e o*ftr ol protEny lho buu! or i,lpmE! rh.frr,
.,rl *h, $d*t n, Gi FuFr! wlh . G,nfu.in |r.tr<n tnrd I' rlE corr4t*'1 b.n- uv)
_l m.rcnpt u lcr Scii,r
IAB8EEIi:qAMEAEAUAN
DECIJEAIIA!
I lEEn, .lfm ud.r Foly of F,ury m .l th folh*ha &.1{.roB:
-lb!r.&lpiudullin.c.nlf.d.olchnE
l0 s.lt-lntur fur wr6' $q.nrr.. r FDYrr.l fo. hv s&rirn r7(l) ot rlr
tlru Cd., tu rtE lErrollr[E. oI rlt mll rd Ehrh rh. Fmr ir Btu.d
I h.r!. -rll Drrrs Pork.ri ..f,{rnurx'n ormr.. 1! rcquftn h, Sdr x,h !7(ll.r rh. Irlrn Cixr.. [i, ttF lrn')'fuE ' or
rlr s.rk ktr wl,khrh^ r(nN r\ \1.(l Mv {ttrl eohFnerin mrurr._c.rfttr ttl F,l.y nuhh.rt.:
I{dnyrh.rmih.FrtormBtolrh.*orlkr*hrhrhrFrnnFrndi.Irhrlln.mPh,rnyFB).tn.nvmar'
o .\ b tBnm ruhj-r l.lh. k*t6' drnpc.t.l nn L*! or Ctllrodo, .nl .aN rhd rr I !L,!lt tE.r {hiar k' rrE
k,rt.r( (,mp.nel ion pmvisonr or Ssl,on t?00 of rht I rtrr. C(xlt. I dEIl, l,ln hw h ohfly wilh rh)t pn,v'\r'nr..
WAnNNC Fnhft r' euE k'*.6' lrnltndi). d,wnlt ! unL*tuL rnt rh.ll 3nl'Fr s dtlt,F kl anlsl FnlF.il
(, o htrndrcd rlnnrdJ dolhri (!l(x).ll(tl). h !'lil ir (, rh. (,{ o, .onll'emln)n dae3cr ri pn'vrl.(l Lr rh'
S(rrr 1076 or rh. lrhtr CqL. Dr.r.{ d,
I lEEh).lli.m ud.r |rn y ol Frrry ttr I d h.n<rl unLr F'vlrn lrrFd 9 (o.Etunl *rh SalD ?m)) ol DrYtrrr :l
of th. Burftrt url Pmf.ribnr Cut. .tl hy ltc.* t! 6 tull nrt .d .fftr
to g1b tzs-
dt-) h. l>
Ih.ftby!lllmunJ.rlxnrlryotP.rurylnalrh.tiu(,nrrtu(r$ntnlmsir.Ny(rlhcJ'.rrorme.ofrh.strklirr*h(hrhFtm{N
ASt TIANLTECIdEA!1A!
I hdlhy rnm und.r Fn.l, oa IErjlry or ol lh. 10110*6r dehnl kr.l
r).mLsn P.rhr+Alkqor flold.trb.IiLnl R.SuLlaN (Trk,lI} P.n6l
_R.queJ lrtl.r ol Nritr.hn
l..ndy rh, rlr ld.r.t E!!Ll-ns as$lot (rE{d! kmv.l & d {?h.bl lo lhu tmFl
I r.n'lvrll( I hrv. rrrlrln\ rlrl rkln rl (rlc rhrlrh. !h'v. nl,) la3rdbcomfly*(h{ll(irylnd(-,nrnrv
'UD. eonqddkr. lrl hcr.trv !trrhrd. rcFcedtr'vci ofrht (-[r r*]O)unrrh.nrcr uF)n rtrtx{uBlt,rl Srir. lir\ t!!uu I
.ll,e mntbr{ Iftr.ny ltr
Appli$nl.r/\qcnl Sisno(u
.1-)L t>'
Site-Work
Underoround
Pole Bases
Lioht Standards
Spas, Pool, Fountains
Siqns (monument)
Life Satety /Low Voltage
Fire Alarm / Dampers
Communicalions Cable
Building
Under Slab / Floor
Bondinq / Groundino / UFER
Transformers
Torqueinq
Sub-Panels
Air Conditioners
Roof Top Equipment
Factory Wired Unit
Walls (Conduit)
Walls (Rouqh)
Ceilinos (Hard & Soff it Rouqh
Ceilinqs (T-Bar Rouqh)
Meter Release
Rouoh
Service Meter I
FINAL \0 )r r+{Vlil/11t1
INotes, Remarks, Etc.
n(EJ rS- !O97. C'!. C )ld.itNtE:
r-
I
I
I
I
I
I
!
I
I
I
SANIA
Planning t Bullding Agency
Building Safety Oivision
20 Clvlc Center Plaza
P.O, Box 1988 ( -19)
Santa Ana, CA92702
(714) 647-5600
www.santa-ana.org
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
sol4't csc 2013
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAmILY RESIDENCES Onty
lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification seclion below. A clpy of this form shall be attach€d to each of TWO sets of plans, of
minimum 11" x 17'
Prorocl Addross:
size. lf answerlnq NO to anv of the ou ons, Dlan check shall be requlred.
,hJA ca qz-b'41o Ei**nost.
tal{1A tLs
Aro ths following appllcablo to the proposed proJect?
Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the Califomia Fire Code, and is this shown on the roof plan?
Wll the PV system be installed on a roof having only one roofing layer with no
overlays?
Wilt the PV anay be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
Will the PV system weigh maximum 4 pounds per square feet or less?
be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
Willthe PV system be installed with a space of 2" minimum to 10" maximum between
the undersid€ of modules and the qurface of the roof?
Will the PV system be installed withdJt using any ballast syst€m or counter-\ueight
system?
Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
\Mll the minimum y16'lag screws be installed with a minimum ol2-1l2inch
omb€dment into roof rafters (with predrilled holes) and is this minimum €mbedment
shown on the plans?
fue ALL the structural pages of the plans stamped and signed by a Califomia
licensed professkrnal engineea (including projec{ specific site plan, F / layout,
anchorage spacing, anchorage details and manufacture/s PV support information.)
I certify under penalty of pedury undor the laus of tha Stato of
Contractor Company Name:
Contractor License Number:
YES NO1aa
26tr
3 [-d El
4gtr
10.
ds
6s
Ma
du
Ma
Print Name:
Phone Number:
'Thoraas /,abr nah,wal (st rrn aau
6
7
I
Signature:
C.tfomta thrt th€ eP.tlglltlo
(J?J^:t -o^* -L
Date;
Email Address
,d6L( ao W1,{ t- Nv.^i.Q, a vrcr l " ttm,
l-IL--T
t\t .
4 v-' ro'c- rt q3
[,xl'l:l)lt't: t) l)l:liMll. ['ROCl,ss [:()ti SMAl.l-5(-Al l, I'V 5\'sI'IN4s
STANr)ARD SrrrrNc 5\'\ r r N1
The informarion in rhis guideline is intended to help local jurisdictions and conrractors idenrify when PV sysrem installations
are simple. needing only a basic review and when an installation is more complex. Ir is likely that 50 -75% of all residenrial
sysaems will comply with these simple criteria. fur projects that fail to meer rhe simple crireria, resolurion sreps have been
suggested to provide as a parh ro permit approval.
Required lnJortnat ion .for Pertnit:
l. Site plan showing loca(ion of major components on rhe protrrty. This drawing need nor be exactly ro scale. bur ir
should represenr relative locarion of componenrs ar sire (see\upplied example sire plan). PV arrays on dwellings
with a 5' perimerer space at ridge and sides may not need separate fire service review.
2. Electrical diagram showing PV array conhguration, wiring system, overcurrent protecrion. inverter. disconnects,
required signs, and ac connecrion ro building (see supplied standard electrical diagram).
3. Specificarion sheets and insrallation manuals (if available) for all manufactured componenrs ancluding, but not
limited (o. PV modules, inverter(s), combiner box. disconnects. and mounting system.
Step 1, Structural Rcuic* o[ PV Array Mounting System
Is the array to be mounted on a defined, p€rmitted roof structur€?
f No due to non-compliant rool or a ground mount, submit completed wo
Roaf lt{'ortnation:
I . ls the roohng type lighrweighr (Yes = composirion. lightweighr ffArtry/i
Etoc
PL
roof
IJ No. submit completed worksheet Ior roof stucture WXSI (No heA v),6l4le. etc
2. Does rhe roof have a single roof covering?a Yes No
rk.sh ture
me
ll *'.--orus
llorrntin-r7 S.t'st (m lnlbrfi it ion :
l. ls rhe mounting strucrure an
benearh the module frames?
IJ No, submit completed worksheet Ior rooJ structure wKSl
L Provide method and rype of weatherproohng roof penerrarions (a g flashing; caulk)
en neered product design to motrnr PV modules wirh no
Yes !No
Ij No, proide detaib of sffuctutal attachment cefiiled by a desigrLpqts€snal
2. For manufactured mounting systems, frll out informario( ofl the mountlng sysrem beloly
a. Mounring Sysrem Manufacrurer lronRidge Producr Namc and Model#lronRidge
b. Total Weight of PV Modules and Rails 871
c. Total Number of Atrachment Points
seal
an I8"gap
o
e
d. Weight per Attachment Point (b + c)25.6 (if g
Maximum Spacing Berween Attachmenr PointS on a. Rail 12
maximum spacing allowed based on maximum design wind speed)
Toral Surface Area of PV Modules (square feeo fr'
reater rhan 45 llrs,sr)
es(se$ ppd '$13'for
f.
g Distributed Weight of PV Module on Roof (b + F)27 lbs/fr'
II distributed weight ol the PV system is greater than 5 lbsfP, see WI<SI . : ' '
Stcp 2, Electrical Revie- o[ PV System (Calculations [o, Eln.t,i.ul D,ag,ar) SEP :
In order for a PV s)rstem to be consldercd for an expedited permlt process, the fiollowing muscw{y:
l. PV modules, urility-in(eractive inveners. and combiner boxes are identihed for use in Pv systems.
2. The PV array is composed of 4 series srrings or less per invener.
3. The total invener capacity has a continuous ac power outpur 13.440 Watts or less
4. The ac interconnecrion point is on rhe load side of service disconnecring means (690.64(8)).
5. One of the s6ndard electrical diagrams (El .1, El.la. El . I b, or E L I c) can be used to accurately represent the Pv
system. lnteractive PDF diagrams are available i( !\\\\\ s(,lirr.il){ \ or(/ln r llrIlllr{
r'.)D?Dn/,rir?1.,. l)r'tt|idr ttti elk,t',t tir'. dii]qnotl tt,irh appropriitt.tl nil
2 I \l't t)t llt) I'l R\|l l'ti()( I\\ I()ti l'\'\\\ \t\
FlashFool
,l
I
STANT)ARI) Sl.IIING SYSTEM SITI. I,LAN
,.
,1,
Site Plan
for SmalFScale, Single-Phase PV Systems
cdt .5r m
AddB rt Prsr
Iw- td!.. Cop.,ty
l51a &!ffi D.. S{rt I lL Sile Name: L,rvr,c,F"
Sile Address: .,o o.ft..n s,. seE
^M c e27or
Svstem AC Size . r.3 rft
e*. lv s.l!, P.nIr S.Pi!. trc
c*i.a rv TIC NTS Darr:09-25-2017 kr4 Total
L
!l
,#il. pacE 3
26 O t€"OC RAFTERS 9q
:T
NH
Its
3Ec
6cNt<(
;qE
*EE
H9$
600FFIIJ
88?B3BIJ
uJF
,
Ii
3
e
rii
o
o
-;ihP-83,'-
E?:!5itI{.i=ig{
ti,vgnonon E
l/SE Prlild Numbar Ula8244ae-l7l
Weeroe,-.n.\n.r..
65 e5"
,,9r
Edfr
E;qE
;qEe
EHE*zzz
EE3f
OE
ES
d9
Un
I
HirYC
6
I
3
I
{r0 I)tAl}t()Nt) STREET
02'5 10' t5' 20 SCALE:
1/8"='l !0"xAlihi,9a!-xl{u!q..'cs.{I
"3',
18 MOOULES
ROOF TrLT @ 20'
AZTMUTH @ 90"
LAMSON
BROS
ELECTRIC
o
I
I
I
I
I
I
il
--,\
t\
I
il
Ir
U I
I
I
I
,,,f:,'. P^cE 2
P/L 67'
9q
'IAH
i;a
:8,
l<r(
;d$
*E*
HgEi=8
9--6
b
o(.)oFFTIJ(aato
88?
=B;POINT LOAO CALCULATIOiI PER ARRAY
rrEM rfF, X.1?9, rot^L r'/Er6rlr
ITIODULES 18 3?.71D3 715 bE
RALS l2O 0.5b! 60 b3
RACKING PARTS 3{ 0.5br 17 lb.
ntT LEGS 0 3.5 b. O b.
ffinff$,i.i rE ..iDs 7e b!
TOTAI 'N,EEHI 071 D6
xotxrlE oL aloi.lldv) 65.95' r39,a1' . lE.OrC.n
VIETGHI PER UOUNT A7l t 3a . 2!.! lb.rlounl
1',-11 I
IU!
t!
bo
)
L
bo
)
t
it
o-
to
-Ji
E3e
€x<98at:{:>:>Qzr=rE?WEIGHT PER SO FI 871 / 325 3q.n.. 2.7|b./tq.lt
wINo UPLIFT CAI.CULATION ((I r P)..8T IO < L r EIO
X..'fffitHI-1.'If, roors . zzoro
P ! lrhd Et.!{ !5 FrLrrra'o.r,-{r.fu !2r 0 4./.
E-1.9 rfr.rna.dmir 2.5 lrn
o. ordry or .c t@E !r
a,
g
g
6
H:E
IE6R
*5sE
^zO6E_r5:
XiE";;v d2
igBt
6.
6E{}
{j--
TO
&ia
?rL
10'
g
I
a
I
trr.c.ct.[EL.o &r ec {IO DIAMOND STREET
0' 4' 10' 20' 30'm'SCALE:
1/16".'l'4"
2 x
Tt
LAMSON
BROS
ELECTRIC
I
II
| ,, uoor...
I
I noor nrr o zo' N--llazlMurHos' l\ I.l L\
.t
I
\TA N(
One-Line Standard Electrical Diagram for
Small-Scale, Single-Phase PV SystemsTlw.l.....bdcdio..r'
Site Address:
Site Name LrY Neu,6
System AC Size
o €QUIPMENT SCHIDULE
_r4
1
2
3
!_
6
7
_8-
9
G LE!!BlPlloN
qoqAEly!9o'4E _-,_
t44E!4Y
$qI.llF.9_s._Eql_
qeug!!!ER (rF usEo)__
qc qrq9, uLE9r ___
9914q$/EEIEL____qE!,,!tErEL([_qxEe)_
4c--P-rqcqryltlqL lrl_usEE
SERMCE PANEL
PART NUMBER
!!,,:]{:r9- -
2
ll..lrrPrlllNTt.3
NOTES
UTII-ITY
SERVICE
lIg_vAc 200 A MArN, _:9LA BUS| =_19_A TNVERTER OCPD
(SEE NOTE 5 FOR INVERTER OCPDs ALSO SEE GUIDE SECTION 9)
a!r
Disregard if
provided with
inverter
BUILDING
GROUNOING
ELECTRODEFOR UNUSED SERIES STRINGS
PUT "N/A' rn BLANK ABOVE
SE€ GUIDEAPPENDIX C FOR
INFORMATION ON MOOULE ANO
ARRAY GROUNOING
A CONDUIT AND CONDUCTOR S(HtOULE
TAG DESCRIPTION OR CONOUCTOR TYPE qo!9.
q4qgE
!!l!h
_y_! ,l!1,_
!!u_i4gqi_sF
CONOUCTORS
1
_ __.t__
!9!D!]I
TYPE
NlA
CONDUIT
stzE
N/A99F:? o o, ryvl4lE a
BAEE goPlqE E_.r grDj
9_o_ ft9.(EG-91
M!1!{:-? o erlH{ry_? tr-!!!!!t?_q
t$l{:1Q orllr{4t1tr pr!!!t1Q
!!!q!LL LEPEqc
!c q Ro vlo r!!G.F-!'lEcIBeqE !e!qr
IHItr? tr et!!!t2 o_ gE!ry-2 tr
INSULATED EGC
2
3
1
5
9_ [,roDULEs rN
SERtES SOURCE-CtRCUtT.
1.80xi,ODULES IN !
se-FiEE36un c ec rn c u tr I
COMEINER rNvttTtR
AC DISCOoc Drsco
MoDULES IN !
se-nressounce-crncurr!
INVERTER
OCPD
ocP )
I MoDULES tN I
seTEsS6uace-crncurr 1
NTS Drre
1
-]
srcrlr" ro -1
ls.trdr.3E!@ tluo I
A A
ltl
Notes for One-Line Standard Electrical
Diagram for Single-Phase PV Systemsi'oukt[b{lcdlo.ny
r5r! sroorh.rdv o, sd.lrL
System AC Size
Site Name
srzE
NTS Dale
SIGNS-SEE GUIDE SECTION 7
NOTES FOR ALL DRAWNGS SIGN FOR DC DISCONNECTPV MODULE RATINGS @ STC (Gurde Seclion 5)iTSolar World
OCPD = OVERCURRENT PROTECTION DEVICE PHOTOVOLTAIC POWER SOURCE
sw 295
NATIONAL ELECTRICAL CODE' REFERENCES
sHovlr.r AS /NEc )oo( )oa)
RATEO MPP CURRENT 30
RATED MPP VOLTAGE 500
M^J( POVTER-POTNT CURRENT (t!,)7U I MAX SYSTEM VOLTAGE 600
MAX POWER-PO|NT VOTTAGE (VMe)28.9 INVERTER RATINGS (Guide Sec,lion 4)
=
MAX CIRCUIT CURRENT
oPEN-CtRCUTT VOLTAGE Crc.)36.7 INVERTER MAKE Solar Edge
SHORT.CIRCUIT CURRENT (I !c)8.17
31.25
TNVERTER MoDEL SE6000 H-US
WARNING: ELECTRICAL SHOCK
HAZARD-{INE ANO LOAO MAY BE
ENERGIZED IN OPEN POSITION
MAX SERTES FUSE (OCPD)MAX DC VOLT RATING 19"0 u
9.,9 K -n208 v
MAXTMUM POWER (Pva)295 w MAX POWER @ 40'C SIGN FOR INVERTER OCPD AND
AC DTSCONNECT (rF USED)
MAX VOLTAGE (TYP 500Ve)600 v NOMINAL AC VOI-TAGE f -soun pv svsreu- I
\IOC TEMP COE
l
IF COEFF SUPPt - ____
FF (hVPCO or %PC !)-0.43 MAX AC CURRENT
30
AC POINT OF CONNECTION
LIED CIRCLE U Hrrs I MAX OCPD RATING
THIS PANEL FED BY MULTIPLE.L'gry,-ITY ANO SOLAR)
NOTES FOR ARRAY CIRCUIT wlRING (Guide Scclion 6 and 8 and Appendix D)NOTES FOR INVERTER CIRCUITS (Guid6 Secton I Bnd 9)
1 ) LOV\EST EXPECl AMBIENT TEMPERATURE SASED OI{ ASHRAE MINIMUM MEAN
EXTREME DRY BULB TEMPERATURE FOR ASHFAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION LOWEST EXPECTEO AMBIENT TEMP ,, "C
1) IF UTILMY REOUIRES A MSIBLE.BREAK SWTCH DOES THIS Sv'JlTCH MEET THE
REQUIREMENT? YES! NOE] }.I/A tr
2) IF GENERATION METER REOUIRED, DOES IHIS METER SOCKET MEET THE
REOUIREMENT? YES ! NO tr N/A O
3) SIZE PHOTOVOLTAIC POV'/ER SOURCE (DC) CONDUCTORS BASED ON MAX
cURRENT oN NEc Bgo 53 stc oR ocpo &Atlilc AT otscoNNEcr
1) SIZE INVERTER OUTPUT CIRCUIT (AC) CONOUCTORS ACCOROIT{G TO ITIVERTER
OCPO AITPERE MTING. (Src Guir. Sccton s)
s) TOTAL OF ' INVERTER OCPO(!). ONE FOR EACH INVERTER. DOES IOTAL
supply SREAREES coMply vt TH 12b% susBAR ExcEpnoN rN 6s0 61(g)(zxa)?YESO NOO
2,) HIGHEST CONTINUOUS A},lBIENT TEMPERATURE EASEO ON ASHRAE HIGHEST
MO}/TH 2% DRY SULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCAION. HIGHEST CONTINUOUS TETTPERATURE -t:_oc
2,) 2OO5 ASHME FUI{OEMENTALS 2'4 DESIGN TEMPERATURES OO NOT EXCEEO
47rc IN THE UNITEO STATES (PALM SPRINGS CA IS 4',1"C), FOR LESS THAN 9
CURRENT.CARRYING CONOUCTORS IN ROOF4IOUNTEO SUNLIT CONDUI AT
LEAST 0,5'ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF
17oC OR LESS (ALL OF UN|TE0 STATES).
a) 12 AWG, gO'C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MOOULES
IMTH l6c OF 7 68 AMPS OR LESS WHEN PROTECTED BY A 1zAUP OR SMALLER
FUSE,
b] IO AIAiG gO€ CONDUCTORS ARE GEiIERALLY ACCEPTABLE FOR MOOULES
IAITH I6C OF S,6 A}'PS OR I.ESS W}IEN PROTECTED BY A
's.AMP
OR SUALLER
FUSE
AC OUTPUT CURRENf
NOMINAL AC VOLTAGE
NOTES FOR S-TANDAI{D S-TRINC S\STEM ELECTI{ICAL DIACRAM
a
._
=:
--!
F
2
:'
!
Site Address ."*" *- .". .,