HomeMy WebLinkAbout1601 N Bristol St - Phase 2 - REV 1 - PlanTRIMAR ENGINEERING
Structural Calculation
Project :Better Buzz - PO Menu & Canopy
Project address:1465 E Vista Way, Suite A
Vista, CA 92084
Prepared for :Western Sign & Awning
GENERAL NOTES
1.) DESIGN CODE : 2022 CBC
2.) DESIGN LOADS :ASCE 7-16
3.) WIND VELOCITY :
4.) PROVIDE PROTECTON AGAINST DISSIMILAR MATERIALS
5.) PROVIDE OPEN ENDS OF HOLLOW SECTIONS WITH FULLY WELDED CAP,
CAP THICKNESS TO BE SIMILAR TO HOLLOW SECTION THICKNESS.
6.) IN CASE OF CONFLICT BETWEEN ARCHITECTURAL/SHOP DRAWINGS &
THIS CALCULATION SET ( INCLUDING ANCHOR CALCULATION DRAWINGS ),
THIS CALCULATION SET SHALL GOVERN.
Prepared By:Cerenico G. Madrona, P.E., M.ASCE
7868 De Soto Ave.
Canoga Park, CA 91304
W: 818-453-0394 C: 818-667-1279
Email: eco@trimarengineering.com
96 MPH
5/27/2025
Job:Better Buzz - PO Menu & Canopy Pg. 2
1465 E Vista Way, Suite A, Vista, CA 92084
Dead Load, D
Element Weight
Sign Cabinet , Speaker Box 4 Psf
Roof cover 3 Psf
( See Western Sign & Awning drawings for structure details )
Risk Category =II
Exposure category (B, C or D) =C
Basic wind speed (3 sec. gust wind) V =96 mph
Topographic factor Kzt =1
Height to grade, in feet =h
Vertical dimension, in feet =s
Horizontal dimension, in feet =B
Return corner horizontal dimension, in feet =Lr
Sign gross area, in square feet =As
Kh = velocity pressure exposure coefficient evaluated at height, h,(Tab. 27.3-1)
Kd = wind directionality factor. (Tab. 26.6-1)=0.85
Site Elevation =461.49 ft.
Ke = ground elevation factor. (Tab. 26.9-1)=1
Velocity pressure, qh = 0.00256 Kh Kzt Kd Ke V2 ( 26.10-1 )
where: G = gust effect factor. (Sec. 26.11, page 269). =0.85
Cf = net force coefficient. (Fig. 29.3-1, page 323)
h Kh s B s / h B / s Lr As Cf qh p Width p
( PSF ) ( Psf ) ( PLF )
Sign Cabinet 5.750 0.85 4.052 6.979 0.70 1.72 0.417 28.28 1.61 17.05 23.33
Speaker Box 1.700 0.85 0.670 2.75 0.39 4.10 0.417 1.84 1.75 17.05 25.36
Pole 9.39 0.85 9.390 0.5 1.00 0.05 0.500 4.70 1.79 17.05 25.94 0.50 13
Use Fig. 27.3-4, MWFRS - Part 1 , Monoslope Free Roofs , θ ≤ 45°Use Fig. 27.3-4, MWFRS - Part 1 , Monoslope Free Roofs , θ ≤ 45°
ROOF LOAD CASE LOAD CASE
ANGLE
Ɵ CNW CNL CNW CNL
1.3 1.6 -0.9 -1.3
1.8 0.6 -1.9 0
Use Fig. 27.3-7, MWFRS - Part 1 , Monoslope Free Roofs , θ ≤ 45°, ϒ = 90°, 270°
ROOF LOAD Horizontal Net Design Pressure
ANGLE CASE Distance from p = qh G CN , (Psf)
Ɵ Windward Edge p
-17.39
-13.04
-8.69
7.24
7.24
4.35
Design based on 2022 CBC, ASCE 7-16
Design Loads
Wind Design Data
Design wind force, F = qh G Cf As
ELEMENT
CN
ALL
A3
≤ h -1.2
> h, ≤ 2h -0.9
> 2h -0.6
B3
≤ h 0.5
> h, ≤ 2h 0.5
> 2h
ϒ = 180°
18.84 23.18
B1 26.08 8.69
Obstructed
Wind Flow
OBSTRUCTED Net Design Pressure
WIND FLOW p = qh G CN , (Psf)
pW pL
ϒ = 0°
( See RISA calcs for structure members design )
A1 - B2
LOAD CASE
ALL
A1 - B2
Net Design Pressure
WIND FLOW p = qh G CN , (Psf)
pW pL
A2 -13.04 -18.84
B2 -27.53 0.00
0.3
OBSTRUCTED
15°A1
Job:Better Buzz - PO Menu & Canopy Pg. 3
1465 E Vista Way, Suite A, Vista, CA 92084
CBC 2022, ASCE 7-16 CHAPTER 11, 12, 13, 15 SEISMIC DESIGN CRITERIA
Risk Category =II
Seismic Importance factor =1
Site class =D
Seismic Design Category =D
Latitude (degrees) :
Longitude (degrees) :
Response Spectral Acc. (0.2 sec) Ss =
Response Spectral Acc.( 1.0 sec) S1 =
Soil Site Class D
Site Coefficient Fa =1.200
Site Coefficient Fv =1.959 ( ASCE 7-16 Table 11.4-2 )
Max Considered Earthquake Acc. SMS =Fa.Ss
Max Considered Earthquake Acc. SM1 =Fv.S1
@ 5% Damped Design SDS =2/3(SMS)
SD1 =2/3(SM1)
Design Base shear ( Equivalent Lateral Force Procedure )
SDS =0.740
SD1 =0.445
V = Cs W
Cs =SDS / ( R / Ie )
TL =8
R =3 Ωo =2 ( ASCE 7-16 Table 15.4-2 )
I e =1
Cs = 0.247
hn =8.93 ft
T = 0.02*hn^0.75 = 0.103 sec
Cs max = SD1 / (T*( R / Ie )) =1.437 But not < 0.03
Cs min = 0.044 SDS Ie =0.033
For S1 ≥ 0.6g : min. Cs = 0.8S1 / ( R / Ie ) =0.091
Cs =0.247 governs
Design base Shear, V = Cs W
Where: W = Structure dead load
Seismic Design Data
33.220654
-117.226052
92.50%g = 0.925g
34.10%g = 0.341g
= 1.110g
= 0.668g
= 0.740g
= 0.445g
( See RISA calcs for structure members design )
Job:Better Buzz - PO Menu & Canopy Pg. 4
1465 E Vista Way, Suite A, Vista, CA 92084
ISOMETRIC VIE
NTS
ALL JOINTS TO BE FULLY WELDED UNLESS OTHERWISE SHOWN IN THE DRAWINGS
( See Western Sign & Awning drawings for structure details )
ELEMENT SHAPE MATERIAL
Post HSS 6 x 6 x 3/16 A500 Grade B
Roof Beam RT 4.00 x 4.00 x 0.188 6061 - T6
MEMBERS DESIGN SUMMARY
Job:Better Buzz - PO Menu & Canopy Pg. 5
1465 E Vista Way, Suite A, Vista, CA 92084
Max. Base Reactions: ( From RISA calcs, LC 20 ,
Lateral Reactions at Base : X = 0.14 kip
Z = -0.073 kip
Resultant lateral reaction force, F = 0.158 kip
Moment Reactions at Base : MX = -0.343 kip-ft
MZ = -2.812 kip-ft
Resultant moment reaction, M = 2.833 kip-ft
Lever arm to Base = M / F = 17.94 Ft.
Design Lateral Force, F = 158 Lb
Required Depth of Embedment, d = 0.5 A { 1 + √ [ 1 +( 4.36 h / A ) ] }
Footing Diameter =2.00 Ft
Soil Pressure =100 PSF/FT
S1 =100 * 2
S1 =268.67 PSF
A =2.34 P / ( S1 b )
A = 2.00 ) = 0.69 Ft
Embedment Depth =
Embedment Depth = 4.03 Ft
USE : 24" Dia. x 4' - 1" Depth, Min. 2,500 psi Concrete Footing
Max. Base Reactions: ( From RISA calcs, LC52, Node N1)
X =0.234 Kip
Y =-0.701 Kip
Z =-0.122 Kip
MX =-0.572 Kip-Ft
MY =0.0 Kip-Ft
MZ =-4.706 Kip-Ft
See HILTI Profis Engineering calcs pages
USE : ( 4 ) 3/4" DIA. x 25" MIN. Embed. Depth,
Hex Head ASTM F1554 GR. 36 Galv. Steel
All- Thread Rod w/ Double Hex nut & washer at Bottom
ends on min. f'c = 2,500 psi Concrete Base
USE : 14-1/2" x 14-1/2" x 3/4" thk.
A36 Galv. Steel Base Plate
Design of Concrete Footing ( Nonconstrained )
Node N 1 )
* ( 4.03 / 3 )
( 2.34 * 158 ) / ( 268.67 *
( 0.5 * 0.7 ) * ( 1 + ( SQRT ( 1+( 4.36 * 17.94 / 0.69 ) ) ) )
Anchor Design
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
3D FRAME
Pg. 6
Better Buzz PO Menu & Canop…
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
MEMBERS
Pg. 7
Better Buzz PO Menu & Canop…
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
BOUNDARY
Pg. 8
Better Buzz PO Menu & Canop…
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
WIND LOAD CASE A1
Pg. 9
Better Buzz PO Menu & Canop…
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
WIND LOAD CASE B1
Pg. 10
Better Buzz PO Menu & Canop…
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
WIND LOAD CASE A2
Pg. 11
Better Buzz PO Menu & Canop…
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
WIND LOAD CASE B2
Pg. 12
Better Buzz PO Menu & Canop…
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
WIND LOAD CASE A3
Pg. 13
Better Buzz PO Menu & Canop…
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
WIND LOAD CASE B3
Pg. 14
Better Buzz PO Menu & Canop…
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 16
Hot Rolled Steel Properties
Label E [ksi] G [ksi] Nu Therm. Coeff. [1e⁵°F⁻¹] Density [k/ft³] Yield [ksi] Ry Fu [ksi] Rt
1 A500 Gr.B RND 29000 11154 0.3 0.65 0.527 42 1.4 58 1.3
2 A500 Gr.B Rect 29000 11154 0.3 0.65 0.527 46 1.4 58 1.3
3 A53 Gr.B 29000 11154 0.3 0.65 0.49 35 1.6 60 1.2
Aluminum Properties
Label E [ksi] G [ksi] Nu Therm. Coeff. [1e⁵°F⁻¹] Density [k/ft³] Table B.4 kt Ftu [ksi] Fty [ksi] Fcy [ksi] Fsu [ksi] Ct
1 6061-T6 10100 3787.5 0.33 1.3 0.1728 Table B.4-2 1 38 35 35 24 141
2 6063-T5 10100 3787.5 0.33 1.3 0.1728 Table B.4-2 1 22 16 16 13 141
3 6063-T6 10100 3787.5 0.33 1.3 0.1728 Table B.4-2 1 30 25 25 19 141
4 6061-T6 W 10100 3787.5 0.33 1.3 0.1728 Table B.4-1 1 24 15 15 15 141
Hot Rolled Steel Section Sets
Label Shape Type Design List Material Design Rule Area [in²]Iyy [in⁴]Izz [in⁴] J [in⁴]
1 Post HSS6X6X3 Column Tube A500 Gr.B Rect Typical 3.98 22.3 22.3 35
Aluminum Section Sets
Label Shape Type Design List Material Design Rule Area [in²] Iyy [in⁴]Izz [in⁴] J [in⁴]
1 Roof Beam RT4X4X0.188 Beam Rectangular Tubes 6061-T6 W Typical 2.87 6.96 6.96 10.4
Member Primary Data
Label I Node J Node Section/Shape Type Design List Material Design Rule
1 M1 N1 N17 Post Column Tube A500 Gr.B Rect Typical
2 M2 N12 N13 RIGID None None RIGID Typical
3 M3 N12 N19 Roof Beam Beam Rectangular Tubes 6061-T6 W Typical
4 M4 N13 N14 RIGID None None RIGID Typical
5 M5 N14 N18 Roof Beam Beam Rectangular Tubes 6061-T6 W Typical
6 M6 N18 N20 Roof Beam Beam Rectangular Tubes 6061-T6 W Typical
7 M7 N19 N18 Roof Beam Beam Rectangular Tubes 6061-T6 W Typical
8 M8 N21 N19 Roof Beam Beam Rectangular Tubes 6061-T6 W Typical
Node Coordinates
Label X [ft] Y [ft] Z [ft] Detach From Diaphragm
1 N1 0.831 0 3.49
2 N2 0.831 1.033 4.865
3 N3 0.831 1.033 2.115
4 N4 0.831 1.7 6.98
5 N5 0.831 1.7 4.865
6 N6 0.831 1.7 2.115
7 N7 0.831 1.7 0
8 N8 0.831 5.747 0
9 N9 0.831 5.747 6.98
10 N10 0 8.063307 0.24
11 N11 0 8.063307 6.74
12 N12 0.831 8.286 3.073
13 N13 0.831 8.286 3.49
14 N14 0.831 8.286 3.907
15 N15 3.8635 9.098654 6.74
16 N16 3.8635 9.098654 0.24
17 N17 0.831 9.39 3.49
18 N18 7.059 9.954988 3.907
19 N19 7.059 9.954988 3.073
20 N20 7.059 9.954988 4.99
21 N21 7.059 9.954988 1.99
22 N22 7.727 10.134 0.24
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 17
Node Coordinates (Continued)
Label X [ft] Y [ft] Z [ft] Detach From Diaphragm
23 N23 7.727 10.134 6.74
Node Boundary Conditions
Node Label X [k/in] Y [k/in] Z [k/in] X Rot [k-ft/rad] Y Rot [k-ft/rad] Z Rot [k-ft/rad]
1 N1 Reaction Reaction Reaction Reaction Reaction Reaction
Basic Load Cases
BLC Description BLC Factor Category X Gravity Y Gravity Z Gravity Distributed Area(Member)
1 Self Weight DL -1
2 Wind Load Case A1 WL 2 4
3 Wind Load Case B1 WL 2 4
4 Wind Load Case A2 WL 2 4
5 Wind Load Case B2 WL 2 4
6 Wind Load Case A3 WL 1 1
7 Wind Load Case B3 WL 1 1
8 Roof cover, Cabinet DL 0 DL 3
9 EQ Load X ELX 0.247
10 EQ Load Z ELZ 0.247
11 BLC 2 Transient Area Loads None 66
12 BLC 3 Transient Area Loads None 66
13 BLC 4 Transient Area Loads None 66
14 BLC 5 Transient Area Loads None 36
15 BLC 6 Transient Area Loads None 56
16 BLC 7 Transient Area Loads None 56
Load Combinations
Description Solve P-Delta BLC Factor BLC Factor BLC Factor Factor
1 ASCE ASD 1 Yes Y DL 1
2 ASCE ASD 3 Yes Y DL 1 RLL 1
3 ASCE ASD 4 Yes Y DL 1 RLL 0.75
4 ASCE ASD 5 Yes Y DL 1 2 0.6
5 ASCE ASD 5 Yes Y DL 1 3 0.6
6 ASCE ASD 5 Yes Y DL 1 4 0.6
7 ASCE ASD 5 Yes Y DL 1 5 0.6
8 ASCE ASD 5 Yes Y DL 1 6 0.6
9 ASCE ASD 5 Yes Y DL 1 7 0.6
10 ASCE ASD 6 Yes Y DL 1 2 0.45 RLL 0.75
11 ASCE ASD 6 Yes Y DL 1 3 0.45 RLL 0.75
12 ASCE ASD 6 Yes Y DL 1 4 0.45 RLL 0.75
13 ASCE ASD 6 Yes Y DL 1 5 0.45 RLL 0.75
14 ASCE ASD 6 Yes Y DL 1 6 0.45 RLL 0.75
15 ASCE ASD 6 Yes Y DL 1 7 0.45 RLL 0.75
16 ASCE ASD 7 Yes Y DL 0.6 2 0.6
17 ASCE ASD 7 Yes Y DL 0.6 3 0.6 0.5
18 ASCE ASD 7 Yes Y DL 0.6 4 0.6 0.5
19 ASCE ASD 7 Yes Y DL 0.6 5 0.6 0.5
20 ASCE ASD 7 Yes Y DL 0.6 6 0.6 0.5
21 ASCE ASD 7 Yes Y DL 0.6 7 0.6 0.5
22 ASCE ASD 8 Yes Y DL 1 Sds*DL 0.14 Om*ELX 0.7
23 ASCE ASD 8 Yes Y DL 1 Sds*DL 0.14 Om*ELZ 0.7
24 ASCE ASD 8 Yes Y DL 1 Sds*DL 0.14 Om*ELX -0.7
25 ASCE ASD 8 Yes Y DL 1 Sds*DL 0.14 Om*ELZ -0.7
26 ASCE ASD 9 Yes Y DL 1 Sds*DL 0.105 Om*ELX 0.525
27 ASCE ASD 9 Yes Y DL 1 Sds*DL 0.105 Om*ELZ 0.525
28 ASCE ASD 9 Yes Y DL 1 Sds*DL 0.105 Om*ELX -0.525
29 ASCE ASD 9 Yes Y DL 1 Sds*DL 0.105 Om*ELZ -0.525
30 ASCE ASD 10 Yes Y DL 0.6 Sds*DL -0.14 Om*ELX 0.7
31 ASCE ASD 10 Yes Y DL 0.6 Sds*DL -0.14 Om*ELZ 0.7
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 18
Load Combinations (Continued)
Description Solve P-Delta BLC Factor BLC Factor BLC Factor Factor
32 ASCE ASD 10 Yes Y DL 0.6 Sds*DL -0.14 Om*ELX -0.7
33 ASCE ASD 10 Yes Y DL 0.6 Sds*DL -0.14 Om*ELZ -0.7
34 ASCE Strength 1 Y DL 1.4
35 ASCE Strength 2 Y DL 1.2 RLL 0.5
36 ASCE Strength 3 Y DL 1.2 RLL 1.6 2 0.5
37 ASCE Strength 3 Y DL 1.2 RLL 1.6 3 0.5
38 ASCE Strength 3 Y DL 1.2 RLL 1.6 4 0.5
39 ASCE Strength 3 Y DL 1.2 RLL 1.6 5 0.5
40 ASCE Strength 3 Y DL 1.2 RLL 1.6 6 0.5
41 ASCE Strength 3 Y DL 1.2 RLL 1.6 7 0.5
42 ASCE Strength 4 Y DL 1.2 2 1 RLL 0.5
43 ASCE Strength 4 Y DL 1.2 3 1 RLL 0.5
44 ASCE Strength 4 Y DL 1.2 4 1 RLL 0.5
45 ASCE Strength 4 Y DL 1.2 5 1 RLL 0.5
46 ASCE Strength 4 Y DL 1.2 6 1 RLL 0.5
47 ASCE Strength 4 Y DL 1.2 7 1 RLL 0.5
48 ASCE Strength 5 Y DL 0.9 2 1
49 ASCE Strength 5 Y DL 0.9 3 1
50 ASCE Strength 5 Y DL 0.9 4 1
51 ASCE Strength 5 Y DL 0.9 5 1
52 ASCE Strength 5 Y DL 0.9 6 1
53 ASCE Strength 5 Y DL 0.9 7 1
54 ASCE Strength 6 Y DL 1.2 Sds*DL 0.2 Om*ELX 1
55 ASCE Strength 6 Y DL 1.2 Sds*DL 0.2 Om*ELZ 1
56 ASCE Strength 6 Y DL 1.2 Sds*DL 0.2 Om*ELX -1
57 ASCE Strength 6 Y DL 1.2 Sds*DL 0.2 Om*ELZ -1
58 ASCE Strength 7 Y DL 0.9 Sds*DL -0.2 Om*ELX 1
59 ASCE Strength 7 Y DL 0.9 Sds*DL -0.2 Om*ELZ 1
60 ASCE Strength 7 Y DL 0.9 Sds*DL -0.2 Om*ELX -1
61 ASCE Strength 7 Y DL 0.9 Sds*DL -0.2 Om*ELZ -1
Member Area Loads (BLC 2 : Wind Load Case A1)
Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
1 N16 N22 N23 N15 Perp Two Way 0.0188 0.0188 0.0188 0.0188
2 N10 N16 N15 N11 Perp Two Way 0.0232 0.0232 0.0232 0.0232
3 N4 N9 N8 N7 Perp Two Way 0.0233 0.0233 0.0233 0.0233
4 N2 N5 N6 N3 Perp Two Way 0.0254 0.0254 0.0254 0.0254
Member Area Loads (BLC 3 : Wind Load Case B1)
Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
1 N16 N22 N23 N15 Perp Two Way 0.0261 0.0261 0.0261 0.0261
2 N10 N16 N15 N11 Perp Two Way 0.0087 0.0087 0.0087 0.0087
3 N4 N9 N8 N7 Perp Two Way 0.0233 0.0233 0.0233 0.0233
4 N2 N5 N6 N3 Perp Two Way 0.0254 0.0254 0.0254 0.0254
Member Area Loads (BLC 4 : Wind Load Case A2)
Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
1 N16 N22 N23 N15 Perp Two Way -0.0188 -0.0188 -0.0188 -0.0188
2 N10 N16 N15 N11 Perp Two Way -0.013 -0.013 -0.013 -0.013
3 N4 N9 N8 N7 Perp Two Way -0.0233 -0.0233 -0.0233 -0.0233
4 N2 N5 N6 N3 Perp Two Way -0.0254 -0.0254 -0.0254 -0.0254
Member Area Loads (BLC 5 : Wind Load Case B2)
Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
1 N16 N22 N23 N15 Perp Two Way 0 0 0 0
2 N10 N16 N15 N11 Perp Two Way -0.0275 -0.0275 -0.0275 -0.0275
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 19
Member Area Loads (BLC 5 : Wind Load Case B2) (Continued)
Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
3 N4 N9 N8 N7 Perp Two Way -0.0233 -0.0233 -0.0233 -0.0233
4 N2 N5 N6 N3 Perp Two Way -0.0254 -0.0254 -0.0254 -0.0254
Member Area Loads (BLC 6 : Wind Load Case A3)
Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
1 N22 N23 N11 N10 Perp Two Way -0.0174 -0.0174 -0.0174 -0.0174
Member Area Loads (BLC 7 : Wind Load Case B3)
Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
1 N22 N23 N11 N10 Perp Two Way 0.0072 0.0072 0.0072 0.0072
Member Area Loads (BLC 8 : Roof cover, Cabinet DL)
Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
1 N11 N10 N22 N23 Y Two Way -0.003 -0.003 -0.003 -0.003
2 N9 N8 N7 N4 Y Two Way -0.004 -0.004 -0.004 -0.004
3 N2 N5 N6 N3 Y Two Way -0.004 -0.004 -0.004 -0.004
Member Distributed Loads (BLC 2 : Wind Load Case A1)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M1 X -0.013 -0.013 0 1
2 M1 X -0.013 -0.013 5.75 9.39
Member Distributed Loads (BLC 3 : Wind Load Case B1)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M1 X -0.013 -0.013 0 1
2 M1 X -0.013 -0.013 5.75 9.39
Member Distributed Loads (BLC 4 : Wind Load Case A2)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M1 X 0.013 0.013 0 1
2 M1 X 0.013 0.013 5.75 9.39
Member Distributed Loads (BLC 5 : Wind Load Case B2)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M1 X 0.013 0.013 0 1
2 M1 X 0.013 0.013 5.75 9.39
Member Distributed Loads (BLC 6 : Wind Load Case A3)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M1 Z 0.013 0.013 0 %100
Member Distributed Loads (BLC 7 : Wind Load Case B3)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M1 Z 0.013 0.013 0 %100
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 20
Member Distributed Loads (BLC 11 : BLC 2 Transient Area Loads)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M3 X 2.863e-6 0.0106 2.5791 3.3528
2 M3 Y -1.068e-5 -0.0396 2.5791 3.3528
3 M3 X 0.0106 0.0163 3.3528 4.1266
4 M3 Y -0.0396 -0.0608 3.3528 4.1266
5 M3 X 0.0163 0.0083 4.1266 4.9003
6 M3 Y -0.0608 -0.031 4.1266 4.9003
7 M3 X 0.0083 0.0053 4.9003 5.674
8 M3 Y -0.031 -0.0196 4.9003 5.674
9 M3 X 0.0053 0.0052 5.674 6.4478
10 M3 Y -0.0196 -0.0194 5.674 6.4478
11 M5 X 5.276e-5 0.0107 2.5791 3.3528
12 M5 Y -0.0001969 -0.0398 2.5791 3.3528
13 M5 X 0.0107 0.0159 3.3528 4.1266
14 M5 Y -0.0398 -0.0592 3.3528 4.1266
15 M5 X 0.0159 0.0084 4.1266 4.9003
16 M5 Y -0.0592 -0.0312 4.1266 4.9003
17 M5 X 0.0084 0.0058 4.9003 5.674
18 M5 Y -0.0312 -0.0216 4.9003 5.674
19 M5 X 0.0058 0.0047 5.674 6.4478
20 M5 Y -0.0216 -0.0177 5.674 6.4478
21 M6 X -0.004 0.0224 0 0.5415
22 M6 Y 0.0148 -0.0837 0 0.5415
23 M6 X 0.0224 0.0646 0.5415 1.083
24 M6 Y -0.0837 -0.2412 0.5415 1.083
25 M7 X 0.0036 0.0036 0 0.834
26 M7 Y -0.0133 -0.0133 0 0.834
27 M8 X 0.0646 0.0224 0 0.5415
28 M8 Y -0.2412 -0.0837 0 0.5415
29 M8 X 0.0224 -0.004 0.5415 1.083
30 M8 Y -0.0837 0.0148 0.5415 1.083
31 M2 X 0.2013 0.066 0 0.1043
32 M2 Y -0.7513 -0.2464 0 0.1043
33 M2 X 0.066 -0.0011 0.1043 0.2085
34 M2 Y -0.2464 0.0039 0.1043 0.2085
35 M2 X -0.0011 0.0001366 0.2085 0.3128
36 M2 Y 0.0039 -0.0005099 0.2085 0.3128
37 M2 X 0.0001366 0.0014 0.3128 0.417
38 M2 Y -0.0005099 -0.0051 0.3128 0.417
39 M3 X 0.0174 0.0221 0 0.7737
40 M3 Y -0.065 -0.0824 0 0.7737
41 M3 X 0.0221 0.0177 0.7737 1.5475
42 M3 Y -0.0824 -0.0659 0.7737 1.5475
43 M3 X 0.0177 0.0177 1.5475 2.3212
44 M3 Y -0.0659 -0.0659 1.5475 2.3212
45 M3 X 0.0177 0.0123 2.3212 3.0949
46 M3 Y -0.0659 -0.046 2.3212 3.0949
47 M3 X 0.0123 0.0002324 3.0949 3.8687
48 M3 Y -0.046 -0.0008673 3.0949 3.8687
49 M4 X -0.0002114 -0.0039 0 0.139
50 M4 Y 0.0007887 0.0147 0 0.139
51 M4 X -0.0039 0.0485 0.139 0.278
52 M4 Y 0.0147 -0.1811 0.139 0.278
53 M4 X 0.0485 0.1572 0.278 0.417
54 M4 Y -0.1811 -0.5865 0.278 0.417
55 M5 X 0.0175 0.0221 0 0.7737
56 M5 Y -0.0652 -0.0824 0 0.7737
57 M5 X 0.0221 0.0176 0.7737 1.5475
58 M5 Y -0.0824 -0.0658 0.7737 1.5475
59 M5 X 0.0176 0.0176 1.5475 2.3212
60 M5 Y -0.0658 -0.0658 1.5475 2.3212
61 M5 X 0.0176 0.0123 2.3212 3.0949
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 21
Member Distributed Loads (BLC 11 : BLC 2 Transient Area Loads) (Continued)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
62 M5 Y -0.0658 -0.0459 2.3212 3.0949
63 M5 X 0.0123 0.0002303 3.0949 3.8687
64 M5 Y -0.0459 -0.0008592 3.0949 3.8687
65 M1 X -0.1628 -0.1628 1.7 5.747
66 M1 X -0.0697 -0.0697 1.033 1.7
Member Distributed Loads (BLC 12 : BLC 3 Transient Area Loads)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M3 X 3.963e-6 0.0147 2.5791 3.3528
2 M3 Y -1.479e-5 -0.0548 2.5791 3.3528
3 M3 X 0.0147 0.0226 3.3528 4.1266
4 M3 Y -0.0548 -0.0842 3.3528 4.1266
5 M3 X 0.0226 0.0115 4.1266 4.9003
6 M3 Y -0.0842 -0.043 4.1266 4.9003
7 M3 X 0.0115 0.0073 4.9003 5.674
8 M3 Y -0.043 -0.0272 4.9003 5.674
9 M3 X 0.0073 0.0072 5.674 6.4478
10 M3 Y -0.0272 -0.0269 5.674 6.4478
11 M5 X 7.304e-5 0.0148 2.5791 3.3528
12 M5 Y -0.0002725 -0.0551 2.5791 3.3528
13 M5 X 0.0148 0.0219 3.3528 4.1266
14 M5 Y -0.0551 -0.0819 3.3528 4.1266
15 M5 X 0.0219 0.0116 4.1266 4.9003
16 M5 Y -0.0819 -0.0432 4.1266 4.9003
17 M5 X 0.0116 0.008 4.9003 5.674
18 M5 Y -0.0432 -0.0299 4.9003 5.674
19 M5 X 0.008 0.0066 5.674 6.4478
20 M5 Y -0.0299 -0.0245 5.674 6.4478
21 M6 X -0.0055 0.031 0 0.5415
22 M6 Y 0.0205 -0.1158 0 0.5415
23 M6 X 0.031 0.0895 0.5415 1.083
24 M6 Y -0.1158 -0.334 0.5415 1.083
25 M7 X 0.0049 0.0049 0 0.834
26 M7 Y -0.0184 -0.0184 0 0.834
27 M8 X 0.0895 0.031 0 0.5415
28 M8 Y -0.3339 -0.1158 0 0.5415
29 M8 X 0.031 -0.0055 0.5415 1.083
30 M8 Y -0.1158 0.0205 0.5415 1.083
31 M2 X 0.0755 0.0248 0 0.1043
32 M2 Y -0.2817 -0.0924 0 0.1043
33 M2 X 0.0248 -0.0003967 0.1043 0.2085
34 M2 Y -0.0924 0.0015 0.1043 0.2085
35 M2 X -0.0003967 5.122e-5 0.2085 0.3128
36 M2 Y 0.0015 -0.0001911 0.2085 0.3128
37 M2 X 5.122e-5 0.0005172 0.3128 0.417
38 M2 Y -0.0001911 -0.0019 0.3128 0.417
39 M3 X 0.0065 0.0083 0 0.7737
40 M3 Y -0.0244 -0.0309 0 0.7737
41 M3 X 0.0083 0.0066 0.7737 1.5475
42 M3 Y -0.0309 -0.0247 0.7737 1.5475
43 M3 X 0.0066 0.0066 1.5475 2.3212
44 M3 Y -0.0247 -0.0247 1.5475 2.3212
45 M3 X 0.0066 0.0046 2.3212 3.0949
46 M3 Y -0.0247 -0.0173 2.3212 3.0949
47 M3 X 0.0046 8.713e-5 3.0949 3.8687
48 M3 Y -0.0173 -0.0003251 3.0949 3.8687
49 M4 X -7.924e-5 -0.0015 0 0.139
50 M4 Y 0.0002957 0.0055 0 0.139
51 M4 X -0.0015 0.0182 0.139 0.278
52 M4 Y 0.0055 -0.0679 0.139 0.278
53 M4 X 0.0182 0.0589 0.278 0.417
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 22
Member Distributed Loads (BLC 12 : BLC 3 Transient Area Loads) (Continued)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
54 M4 Y -0.0679 -0.2199 0.278 0.417
55 M5 X 0.0066 0.0083 0 0.7737
56 M5 Y -0.0244 -0.0309 0 0.7737
57 M5 X 0.0083 0.0066 0.7737 1.5475
58 M5 Y -0.0309 -0.0247 0.7737 1.5475
59 M5 X 0.0066 0.0066 1.5475 2.3212
60 M5 Y -0.0247 -0.0247 1.5475 2.3212
61 M5 X 0.0066 0.0046 2.3212 3.0949
62 M5 Y -0.0247 -0.0172 2.3212 3.0949
63 M5 X 0.0046 8.632e-5 3.0949 3.8687
64 M5 Y -0.0172 -0.0003221 3.0949 3.8687
65 M1 X -0.1628 -0.1628 1.7 5.747
66 M1 X -0.0697 -0.0697 1.033 1.7
Member Distributed Loads (BLC 13 : BLC 4 Transient Area Loads)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M3 X -2.863e-6 -0.0106 2.5791 3.3528
2 M3 Y 1.068e-5 0.0396 2.5791 3.3528
3 M3 X -0.0106 -0.0163 3.3528 4.1266
4 M3 Y 0.0396 0.0608 3.3528 4.1266
5 M3 X -0.0163 -0.0083 4.1266 4.9003
6 M3 Y 0.0608 0.031 4.1266 4.9003
7 M3 X -0.0083 -0.0053 4.9003 5.674
8 M3 Y 0.031 0.0196 4.9003 5.674
9 M3 X -0.0053 -0.0052 5.674 6.4478
10 M3 Y 0.0196 0.0194 5.674 6.4478
11 M5 X -5.276e-5 -0.0107 2.5791 3.3528
12 M5 Y 0.0001969 0.0398 2.5791 3.3528
13 M5 X -0.0107 -0.0159 3.3528 4.1266
14 M5 Y 0.0398 0.0592 3.3528 4.1266
15 M5 X -0.0159 -0.0084 4.1266 4.9003
16 M5 Y 0.0592 0.0312 4.1266 4.9003
17 M5 X -0.0084 -0.0058 4.9003 5.674
18 M5 Y 0.0312 0.0216 4.9003 5.674
19 M5 X -0.0058 -0.0047 5.674 6.4478
20 M5 Y 0.0216 0.0177 5.674 6.4478
21 M6 X 0.004 -0.0224 0 0.5415
22 M6 Y -0.0148 0.0837 0 0.5415
23 M6 X -0.0224 -0.0646 0.5415 1.083
24 M6 Y 0.0837 0.2412 0.5415 1.083
25 M7 X -0.0036 -0.0036 0 0.834
26 M7 Y 0.0133 0.0133 0 0.834
27 M8 X -0.0646 -0.0224 0 0.5415
28 M8 Y 0.2412 0.0837 0 0.5415
29 M8 X -0.0224 0.004 0.5415 1.083
30 M8 Y 0.0837 -0.0148 0.5415 1.083
31 M2 X -0.1133 -0.0371 0 0.1043
32 M2 Y 0.4227 0.1386 0 0.1043
33 M2 X -0.0371 0.0005953 0.1043 0.2085
34 M2 Y 0.1386 -0.0022 0.1043 0.2085
35 M2 X 0.0005953 -7.686e-5 0.2085 0.3128
36 M2 Y -0.0022 0.0002868 0.2085 0.3128
37 M2 X -7.686e-5 -0.0007762 0.3128 0.417
38 M2 Y 0.0002868 0.0029 0.3128 0.417
39 M3 X -0.0098 -0.0124 0 0.7737
40 M3 Y 0.0366 0.0463 0 0.7737
41 M3 X -0.0124 -0.0099 0.7737 1.5475
42 M3 Y 0.0463 0.0371 0.7737 1.5475
43 M3 X -0.0099 -0.0099 1.5475 2.3212
44 M3 Y 0.0371 0.0371 1.5475 2.3212
45 M3 X -0.0099 -0.0069 2.3212 3.0949
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 23
Member Distributed Loads (BLC 13 : BLC 4 Transient Area Loads) (Continued)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
46 M3 Y 0.0371 0.0259 2.3212 3.0949
47 M3 X -0.0069 -0.0001307 3.0949 3.8687
48 M3 Y 0.0259 0.0004879 3.0949 3.8687
49 M4 X 0.0001189 0.0022 0 0.139
50 M4 Y -0.0004437 -0.0082 0 0.139
51 M4 X 0.0022 -0.0273 0.139 0.278
52 M4 Y -0.0082 0.1019 0.139 0.278
53 M4 X -0.0273 -0.0884 0.278 0.417
54 M4 Y 0.1019 0.3299 0.278 0.417
55 M5 X -0.0098 -0.0124 0 0.7737
56 M5 Y 0.0367 0.0464 0 0.7737
57 M5 X -0.0124 -0.0099 0.7737 1.5475
58 M5 Y 0.0464 0.037 0.7737 1.5475
59 M5 X -0.0099 -0.0099 1.5475 2.3212
60 M5 Y 0.037 0.037 1.5475 2.3212
61 M5 X -0.0099 -0.0069 2.3212 3.0949
62 M5 Y 0.037 0.0258 2.3212 3.0949
63 M5 X -0.0069 -0.0001295 3.0949 3.8687
64 M5 Y 0.0258 0.0004834 3.0949 3.8687
65 M1 X 0.1626 0.1626 1.7 5.747
66 M1 X 0.0699 0.0699 1.033 1.7
Member Distributed Loads (BLC 14 : BLC 5 Transient Area Loads)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M2 X -0.2391 -0.0784 0 0.1043
2 M2 Y 0.8923 0.2926 0 0.1043
3 M2 X -0.0784 0.0013 0.1043 0.2085
4 M2 Y 0.2926 -0.0047 0.1043 0.2085
5 M2 X 0.0013 -0.0001623 0.2085 0.3128
6 M2 Y -0.0047 0.0006056 0.2085 0.3128
7 M2 X -0.0001623 -0.0016 0.3128 0.417
8 M2 Y 0.0006056 0.0061 0.3128 0.417
9 M3 X -0.0207 -0.0262 0 0.7737
10 M3 Y 0.0772 0.0978 0 0.7737
11 M3 X -0.0262 -0.021 0.7737 1.5475
12 M3 Y 0.0978 0.0783 0.7737 1.5475
13 M3 X -0.021 -0.021 1.5475 2.3212
14 M3 Y 0.0783 0.0783 1.5475 2.3212
15 M3 X -0.021 -0.0146 2.3212 3.0949
16 M3 Y 0.0783 0.0547 2.3212 3.0949
17 M3 X -0.0146 -0.000276 3.0949 3.8687
18 M3 Y 0.0547 0.001 3.0949 3.8687
19 M4 X 0.000251 0.0047 0 0.139
20 M4 Y -0.0009367 -0.0174 0 0.139
21 M4 X 0.0047 -0.0576 0.139 0.278
22 M4 Y -0.0174 0.2151 0.139 0.278
23 M4 X -0.0576 -0.1867 0.278 0.417
24 M4 Y 0.2151 0.6965 0.278 0.417
25 M5 X -0.0208 -0.0262 0 0.7737
26 M5 Y 0.0775 0.0979 0 0.7737
27 M5 X -0.0262 -0.0209 0.7737 1.5475
28 M5 Y 0.0979 0.0781 0.7737 1.5475
29 M5 X -0.0209 -0.0209 1.5475 2.3212
30 M5 Y 0.0781 0.0781 1.5475 2.3212
31 M5 X -0.0209 -0.0146 2.3212 3.0949
32 M5 Y 0.0781 0.0546 2.3212 3.0949
33 M5 X -0.0146 -0.0002735 3.0949 3.8687
34 M5 Y 0.0546 0.001 3.0949 3.8687
35 M1 X 0.1626 0.1626 1.7 5.747
36 M1 X 0.0699 0.0699 1.033 1.7
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 24
Member Distributed Loads (BLC 15 : BLC 6 Transient Area Loads)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M5 X -0.016 -0.0162 1.2896 2.5791
2 M5 Y 0.0595 0.0603 1.2896 2.5791
3 M5 X -0.0162 -0.0124 2.5791 3.8687
4 M5 Y 0.0603 0.0464 2.5791 3.8687
5 M5 X -0.0124 -0.0072 3.8687 5.1582
6 M5 Y 0.0464 0.0269 3.8687 5.1582
7 M5 X -0.0072 -0.0013 5.1582 6.4478
8 M5 Y 0.0269 0.0047 5.1582 6.4478
9 M6 X 0.0024 -0.0004147 0 0.2708
10 M6 Y -0.0089 0.0015 0 0.2708
11 M6 X -0.0004147 -0.0044 0.2708 0.5415
12 M6 Y 0.0015 0.0165 0.2708 0.5415
13 M6 X -0.0044 -0.0413 0.5415 0.8123
14 M6 Y 0.0165 0.154 0.5415 0.8123
15 M6 X -0.0413 -0.1097 0.8123 1.083
16 M6 Y 0.154 0.4093 0.8123 1.083
17 M7 X -0.005 -0.005 0 0.834
18 M7 Y 0.0185 0.0185 0 0.834
19 M8 X -0.1098 -0.0413 0 0.2707
20 M8 Y 0.4097 0.154 0 0.2707
21 M8 X -0.0413 -0.0044 0.2707 0.5415
22 M8 Y 0.154 0.0165 0.2707 0.5415
23 M8 X -0.0044 -0.0004101 0.5415 0.8122
24 M8 Y 0.0165 0.0015 0.5415 0.8122
25 M8 X -0.0004101 0.0024 0.8122 1.083
26 M8 Y 0.0015 -0.009 0.8122 1.083
27 M2 X -0.1783 -0.0572 0 0.0834
28 M2 Y 0.6652 0.2134 0 0.0834
29 M2 X -0.0572 0.0023 0.0834 0.1668
30 M2 Y 0.2134 -0.0087 0.0834 0.1668
31 M2 X 0.0023 -0.0017 0.1668 0.2502
32 M2 Y -0.0087 0.0065 0.1668 0.2502
33 M2 X -0.0017 -0.0007516 0.2502 0.3336
34 M2 Y 0.0065 0.0028 0.2502 0.3336
35 M2 X -0.0007516 0.0058 0.3336 0.417
36 M2 Y 0.0028 -0.0217 0.3336 0.417
37 M3 X -0.0156 -0.015 0 1.2896
38 M3 Y 0.0582 0.0559 0 1.2896
39 M3 X -0.015 -0.0156 1.2896 2.5791
40 M3 Y 0.0559 0.0581 1.2896 2.5791
41 M3 X -0.0156 -0.0132 2.5791 3.8687
42 M3 Y 0.0581 0.0492 2.5791 3.8687
43 M3 X -0.0132 -0.007 3.8687 5.1582
44 M3 Y 0.0492 0.026 3.8687 5.1582
45 M3 X -0.007 -0.0011 5.1582 6.4478
46 M3 Y 0.026 0.0039 5.1582 6.4478
47 M4 X 0.0062 0.0001456 0 0.1042
48 M4 Y -0.023 -0.0005433 0 0.1042
49 M4 X 0.0001456 -0.0002228 0.1042 0.2085
50 M4 Y -0.0005433 0.0008313 0.1042 0.2085
51 M4 X -0.0002228 -0.0464 0.2085 0.3127
52 M4 Y 0.0008313 0.1732 0.2085 0.3127
53 M4 X -0.0464 -0.1476 0.3127 0.417
54 M4 Y 0.1732 0.5508 0.3127 0.417
55 M5 X -0.0125 -0.016 0 1.2896
56 M5 Y 0.0468 0.0595 0 1.2896
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 25
Member Distributed Loads (BLC 16 : BLC 7 Transient Area Loads)
Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
1 M2 X 0.0742 0.0238 0 0.0834
2 M2 Y -0.2769 -0.0889 0 0.0834
3 M2 X 0.0238 -0.0009735 0.0834 0.1668
4 M2 Y -0.0889 0.0036 0.0834 0.1668
5 M2 X -0.0009735 0.00072 0.1668 0.2502
6 M2 Y 0.0036 -0.0027 0.1668 0.2502
7 M2 X 0.00072 0.0003129 0.2502 0.3336
8 M2 Y -0.0027 -0.0012 0.2502 0.3336
9 M2 X 0.0003129 -0.0024 0.3336 0.417
10 M2 Y -0.0012 0.009 0.3336 0.417
11 M3 X 0.0065 0.0062 0 1.2896
12 M3 Y -0.0242 -0.0233 0 1.2896
13 M3 X 0.0062 0.0065 1.2896 2.5791
14 M3 Y -0.0233 -0.0242 1.2896 2.5791
15 M3 X 0.0065 0.0055 2.5791 3.8687
16 M3 Y -0.0242 -0.0205 2.5791 3.8687
17 M3 X 0.0055 0.0029 3.8687 5.1582
18 M3 Y -0.0205 -0.0108 3.8687 5.1582
19 M3 X 0.0029 0.0004378 5.1582 6.4478
20 M3 Y -0.0108 -0.0016 5.1582 6.4478
21 M4 X -0.0026 -6.062e-5 0 0.1042
22 M4 Y 0.0096 0.0002262 0 0.1042
23 M4 X -6.062e-5 9.275e-5 0.1042 0.2085
24 M4 Y 0.0002262 -0.0003461 0.1042 0.2085
25 M4 X 9.275e-5 0.0193 0.2085 0.3127
26 M4 Y -0.0003461 -0.0721 0.2085 0.3127
27 M4 X 0.0193 0.0615 0.3127 0.417
28 M4 Y -0.0721 -0.2293 0.3127 0.417
29 M5 X 0.0052 0.0066 0 1.2896
30 M5 Y -0.0195 -0.0248 0 1.2896
31 M5 X 0.0066 0.0067 1.2896 2.5791
32 M5 Y -0.0248 -0.0251 1.2896 2.5791
33 M5 X 0.0067 0.0052 2.5791 3.8687
34 M5 Y -0.0251 -0.0193 2.5791 3.8687
35 M5 X 0.0052 0.003 3.8687 5.1582
36 M5 Y -0.0193 -0.0112 3.8687 5.1582
37 M5 X 0.003 0.0005244 5.1582 6.4478
38 M5 Y -0.0112 -0.002 5.1582 6.4478
39 M6 X -0.0009981 0.0001726 0 0.2708
40 M6 Y 0.0037 -0.0006442 0 0.2708
41 M6 X 0.0001726 0.0018 0.2708 0.5415
42 M6 Y -0.0006442 -0.0069 0.2708 0.5415
43 M6 X 0.0018 0.0172 0.5415 0.8123
44 M6 Y -0.0069 -0.0641 0.5415 0.8123
45 M6 X 0.0172 0.0457 0.8123 1.083
46 M6 Y -0.0641 -0.1704 0.8123 1.083
47 M7 X 0.0021 0.0021 0 0.834
48 M7 Y -0.0077 -0.0077 0 0.834
49 M8 X 0.0457 0.0172 0 0.2707
50 M8 Y -0.1706 -0.0641 0 0.2707
51 M8 X 0.0172 0.0018 0.2707 0.5415
52 M8 Y -0.0641 -0.0069 0.2707 0.5415
53 M8 X 0.0018 0.0001708 0.5415 0.8122
54 M8 Y -0.0069 -0.0006372 0.5415 0.8122
55 M8 X 0.0001708 -0.001 0.8122 1.083
56 M8 Y -0.0006372 0.0037 0.8122 1.083
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 26
Envelope Node Reactions
Node Label X [k] LC Y [k] LC Z [k] LC MX [k-ft] LC MY [k-ft] LC MZ [k-ft] LC
1 N1 max 0.319 17 0.825 4 0 4 0.001 4 0 16 2.019 5
2 min -0.348 7 -0.409 20 -0.073 9 -0.345 9 0 7 -2.812 20
3 Totals:max 0.319 17 0.825 4 0 4
4 min -0.348 7 -0.409 20 -0.073 9
Envelope AISC 15TH (360-16): ASD Member Steel Code Checks
Member Shape Code Check Loc[ft] LC Shear Check Loc[ft] Dir LC Pnc/om [k]Pnt/om [k]Mnyy/om [k-ft]Mnzz/om [k-ft] Cb Eqn
1 M1 HSS6X6X3 0.172 0 20 0.011 0 y 19 94.129 109.629 18.501 18.501 1.227 H1-1b
Envelope AA ADM1-20: ASD - BUILDING Member Aluminum Code Checks
Member Shape Code CheckLoc[ft]LCShear CheckLoc[ft]DirLCPnc/Om[k]Pnt/Om[k] Mny/Om[k-ft] Mnz/Om[k-ft] Vny/Om[k] Vnz/Om[k]Cb Eqn
1 M3 RT4X4X0.188 0.485 0 5 0.046 0 y 4 21.185 26.091 2.636 2.636 7.047 7.047 2.049 H.1-1
2 M5 RT4X4X0.188 0.485 0 5 0.046 0 y 4 21.185 26.091 2.636 2.636 7.047 7.047 2.048 H.1-1
3 M6 RT4X4X0.188 0.034 0 5 0.013 0.056 y 5 26.091 26.091 2.636 2.636 7.047 7.047 2.14 H.1-1
4 M7 RT4X4X0.188 0.032 0 5 0.001 0 y 5 26.091 26.091 2.636 2.636 7.047 7.047 1.016 H.1-1
5 M8 RT4X4X0.188 0.034 1.083 5 0.013 1.027 y 5 26.091 26.091 2.636 2.636 7.047 7.047 2.14 H.1-1
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 27
Node Reactions
LC Node Label X [k] Y [k] Z [k] MX [k-ft] MY [k-ft] MZ [k-ft]LC Node Label X [k] Y [k] Z [k] MX [k-ft] MY [k-ft] MZ [k-ft]
1 20 N1 0.14 -0.409 -0.073 -0.343 0 -2.812
2 20 Totals:0.14 -0.409 -0.073
3 20 COG (ft):X: 4.607 Y: 10.018 Z: 3.489
Company
Designer
Job Number
Model Name
:
:
:
:
Trimar Engineering
CM
Better Buzz PO Menu & Canopy
Checked By : CM
RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 28
Node Reactions
LC Node Label X [k] Y [k] Z [k] MX [k-ft] MY [k-ft] MZ [k-ft]LC Node Label X [k] Y [k] Z [k] MX [k-ft] MY [k-ft] MZ [k-ft]
1 52 N1 0.234 -0.701 -0.122 -0.572 0 -4.706
2 52 Totals:0.234 -0.701 -0.122
3 52 COG (ft):X: 4.533 Y: 9.909 Z: 3.489
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
29
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Better Buzz - Menu & Canopy Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
29
CM
eco@trimarengineering.com
5/27/2025
Specifier's comments: Better Buzz - PO Menu & Canopy
1 Anchor Design
1.1 Input data
Anchor type and diameter: Hex Head ASTM F 1554 GR. 36 3/4
Item number: not available
Specification text:Æ 3/4 in Hex Head ASTM F 1554 GR. 36 with
25 in nominal embedment depth per Technical
data , cast in place installation per MPII,
Effective embedment depth: hef = 25.000 in.
Material: ASTM F 1554
Evaluation Service Report: Hilti Technical Data
Issued I Valid: - | -
Proof: Design Method ACI 318-19 / CIP
Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-19 Fig. R.17.7.2.1b)
Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.750 in.
Anchor plateCBFEM : lx x ly x t = 14.500 in. x 14.500 in. x 0.750 in.;
Profile: Square HSS (AISC), HSS6X6X.1875; (L x W x T) = 6.000 in. x 6.000 in. x 0.188 in.
Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 49.000 in.
Reinforcement: tension: not present, shear: not present;
edge reinforcement: none or < No. 4 bar
CBFEM - The anchor calculation is based on a component-based Finite Element Method (CBFEM)
Geometry [in.] & Loading [kip, ft.kip]
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
30
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Better Buzz - Menu & Canopy Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
30
CM
eco@trimarengineering.com
5/27/2025
1.1.1 Design results
Case Description Forces [kip] / Moments [ft.kip]Seismic Max. Util. Anchor [%]
1 Combination 1 N = 0.701; Vx = 0.234; Vy = -0.122;
Mx = 0.57200; My = -4.70600; Mz = 0.00000;
no 81
1.2 Load case/Resulting anchor forces
Anchor reactions [kip]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 -0.000 0.068 0.059 -0.034
2 3.549 0.059 0.057 -0.012
3 0.000 0.068 0.062 -0.027
4 4.083 0.073 0.055 -0.048
Resulting tension force in (x/y)=(4.750/0.332): 7.632 [kip]
Resulting compression force in (x/y)=(-2.142/-0.640): 7.216 [kip]
Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)
1.3 Tension load
Load Nua [kip]Capacity f Nn [kip]Utilization bN = Nua/f Nn Status
Steel Strength*4.083 14.529 29 OK
Pullout Strength*4.083 9.156 45 OK
Concrete Breakout Failure**7.632 9.449 81 OK
Concrete Side-Face Blowout, direction y+*4.083 11.960 35 OK
* highest loaded anchor **anchor group (anchors in tension)
1.3.1 Steel Strength
Nsa [kip]f f Nsa [kip]Nua [kip]
19.372 0.750 14.529 4.083
1.3.2 Pullout Strength
Np [kip]y c,p l a f f Npn [kip]Nua [kip]
13.080 1.000 1 0.700 9.156 4.083
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
31
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Better Buzz - Menu & Canopy Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
31
CM
eco@trimarengineering.com
5/27/2025
1.3.3 Concrete Breakout Failure
ANc [in.2]ANc0 [in.2]ca,min [in.]cac [in.]y c,N hef [in.]
402.56 874.03 5.282 -1.000 9.855
ec1,N [in.]y ec1,N ec2,N [in.]y ec2,N y ed,N kcr
0.000 1.000 0.332 0.978 0.807 24
l a Nb [kip]f f Ncbg [kip]Nua [kip]
1.000 37.123 0.700 9.449 7.632
1.3.4 Concrete Side-Face Blowout, direction y+
ca1 [in.]Abrg [in.2]l a Nsb [kip]agroup s [in.]
5.282 0.65 1.000 17.086 1.000 -
NSbg [kip]f f NSbg [kip]Nua [kip]
17.086 0.700 11.960 4.083
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
32
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Better Buzz - Menu & Canopy Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
32
CM
eco@trimarengineering.com
5/27/2025
1.4 Shear load
Load Vua [kip]Capacity f Vn [kip]Utilization bV = Vua/f Vn Status
Steel Strength*0.073 7.555 1 OK
Steel failure (with lever arm)*N/A N/A N/A N/A
Pryout Strength**0.264 40.045 1 OK
Concrete edge failure in direction x+**0.264 4.347 7 OK
* highest loaded anchor **anchor group (relevant anchors)
1.4.1 Steel Strength
Vsa [kip]f f Vsa [kip]Vua [kip]
11.623 0.650 7.555 0.073
1.4.2 Pryout Strength
ANc [in.2]ANc0 [in.2]ca,min [in.]kcp cac [in.]y c,N hef [in.]
402.56 111.60 5.282 2 -1.000 3.521
ec1,V [in.]y ec1,V ec2,V [in.]y ec2,V y ed,N kcr
0.000 1.000 0.000 1.000 1.000 24
l a Nb [kip]f f Vcpg [kip]Vua [kip]
1.000 7.929 0.700 40.045 0.264
1.4.3 Concrete edge failure in direction x+
le [in.]d0 [in.]c1 [in.]AVc [in.2]AVc0 [in.2]
6.000 0.750 5.282 158.97 125.55
y ed,V y parallel,V ec,V [in.]y ec,V y c,V y h,V
0.900 1.000 0.019 0.998 1.000 1.000
l a Vb [kip]f f Vcbg [kip]Vua [kip]
1.000 5.463 0.700 4.347 0.264
1.5 Combined tension and shear loads, per ACI 318-19 section 17.8
bN bV z Utilization bN,V [%]Status
0.808 0.061 5/3 71 OK
bNV = bz
N + bz
V <= 1
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
33
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Better Buzz - Menu & Canopy Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
33
CM
eco@trimarengineering.com
5/27/2025
1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA TR029,
etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum
required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• The equations presented in this report are based on imperial units. When inputs are displayed in metric units, the user should be aware that the
equations remain in their imperial format.
• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential
concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout
or pryout strength governs.
• For additional information about ACI 318 strength design provisions, please go to
https://viewer.joomag.com/profis-design-guide-us-en-summer-2021/0841849001625154758?short&/
• Attention! In case of compressive anchor forces a buckling check as well as the proof of the local load transfer into and within the base material
(incl. punching) has to be done separately.
• The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to elastic/plastic
displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment."
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
34
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Better Buzz - Menu & Canopy Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
34
CM
eco@trimarengineering.com
5/27/2025
Coordinates Anchor [in.]
Anchor x y c-x c+x c-y c+y
1 -4.750 -4.750 5.282 14.782 5.282 14.782
2 4.750 -4.750 14.782 5.282 5.282 14.782
3 -4.750 4.750 5.282 14.782 14.782 5.282
4 4.750 4.750 14.782 5.282 14.782 5.282
1.7 Installation data
Anchor type and diameter: Hex Head ASTM F 1554 GR.
36 3/4
Profile: Square HSS (AISC), HSS6X6X.1875; (L x W x T) = 6.000 in. x 6.000
in. x 0.188 in.
Item number: not available
Hole diameter in the fixture: df = 0.812 in. Maximum installation torque: -
Plate thickness (input): 0.750 in. Hole diameter in the base material: - in.
Hole depth in the base material: 25.000 in.
Minimum thickness of the base material: 26.000 in.
Æ 3/4 in Hex Head ASTM F 1554 GR. 36 with 25 in nominal embedment depth per Technical data , cast in place installation per MPII
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:35
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Better Buzz - Menu & Canopy Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
35
2 Anchor plate design
2.1 Input data
Anchor plate:Shape: Rectangular
lx x ly x t = 14.500 in x 14.500 in x 0.750 in
Calculation: CBFEM
Material: ASTM A36; Fy = 36,000 psi; εlim = 5.00%
Anchor type and size:Hex Head ASTM F 1554 GR. 36 3/4, hef = 25.000 in
Anchor stiffness:The anchor is modeled considering stiffness values determined from load displacement curves tested in an
independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor
stiffness has a major impact on the load distribution results.
Design method:AISC and LRFD-based design using component-based FEM
Stand-off installation:eb = 0.000 in (No stand-off); t = 0.750 in
Profile:HSS6X6X.1875; (L x W x T x FT) = 6.000 in x 6.000 in x 0.188 in x -
Material: ASTM A500 Gr.B Rect; Fy = 46,000 psi; εlim = 5.00%
Eccentricity x: 0.000 in
Eccentricity y: 0.000 in
Base material:Cracked concrete; 2500; fc,cyl = 2,500 psi; h = 49.000 in
Welds (profile to anchor plate):Type of redistribution: Plastic
Material: E70xx
Mesh size:Number of elements on edge: 8
Min. size of element: 0.394 in
Max. size of element: 1.969 in
2.2 Summary
Description Profile Anchor plate Concrete [%]
sEd [psi]ePl [%]sEd [psi]ePl [%]Hole bearing [%]
1 Combination 1 23,907 0.00 10,571 0.00 1 5
2.3 Anchor plate classification
Results below are displayed for the decisive load combinations: Combination 1
Anchor tension forces Equivalent rigid anchor plate (CBFEM)Component-based Finite Element Method
(CBFEM) anchor plate design
Anchor 1 -0.000 kip -0.000 kip
Anchor 2 2.674 kip 3.549 kip
Anchor 3 0.000 kip 0.000 kip
Anchor 4 3.156 kip 4.083 kip
User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can be
applied.
2.4 Profile/Stiffeners/Plate
Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for critical
cross sections, which should be performed outside of PROFIS Engineering.
2.4.1 Equivalent stress and plastic strain
Part Load
combination
Material fy [psi]elim [%]sEd [psi]ePl [%]Status
Plate Combination 1 ASTM A36 36,000 5.00 10,571 0.00 OK
Profile Combination 1 ASTM A500 Gr.B 46,000 5.00 14,247 0.00 OK
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:36
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Better Buzz - Menu & Canopy Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
36
Part Load
combination
Material fy [psi]elim [%]sEd [psi]ePl [%]Status
Rect
Profile Combination 1 ASTM A500 Gr.B
Rect
46,000 5.00 23,907 0.00 OK
Profile Combination 1 ASTM A500 Gr.B
Rect
46,000 5.00 14,958 0.00 OK
Profile Combination 1 ASTM A500 Gr.B
Rect
46,000 5.00 18,129 0.00 OK
2.4.1.1 Equivalent stress
Results below are displayed for the decisive load combination: 1 - Combination 1
46,000 psi
0 psi
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:37
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Better Buzz - Menu & Canopy Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
37
2.4.1.2 Plastic strain
Results below are displayed for the decisive load combination: 1 - Combination 1
5.00%
0.00%
2.4.2 Plate hole bearing resistance, AISC 360-16 Section J3
Decisive load combination: 1 - Combination 1
Results
V [kip]FRn [kip]Utilization [%]Status
Anchor 1 0.068 58.725 1 OK
Anchor 2 0.059 58.725 1 OK
Anchor 3 0.068 58.725 1 OK
Anchor 4 0.073 58.725 1 OK
2.5 Concrete
Decisive load combination: 1 - Combination 1
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:38
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Better Buzz - Menu & Canopy Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
38
2.5.1 Compression in concrete under the anchor plate
318 psi
0 psi
2.5.2 Concrete block compressive strength resistance check, AISC 360-16 Section J8
Results
Load combination Fp [psi]s [psi]Utilization [%]Status
Combination 1 2,225 110 5 OK
2.6 Symbol explanation
elim Limit plastic strain
ePl Plastic strain from CBFEM results
Fp Concrete block design bearing strength
fy Yield strength
s Average stress in concrete
sEd Equivalent stress
FRn Factored resistance
V Resultant of shear forces Vy, Vz in bolt.
2.7 Warnings
●By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability and
adequacy for your specific jurisdiction and project requirements.
●The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory. Please
note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution results.
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:39
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Better Buzz - Menu & Canopy Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
39
3 Summary of results
Design of the anchor plate, anchors, welds and other elements are based on CBFEM (component based finite element method) and AISC.
Load combination Max. utilization Status
Anchors Combination 1 81%OK
Anchor plate Combination 1 30%OK
Concrete Combination 1 5%OK
Profile Combination 1 52%OK
Fastening meets the design criteria!
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:40
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Better Buzz - Menu & Canopy Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
40
4 Remarks; Your Cooperation Duties
●Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to
using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put
in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret
norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a
specific application.
●You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not
use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in
each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.
TRIMAR ENGINEERING
Structural Calculation
Project :Better Buzz - Menuboard
Project address:1465 E Vista Way, Suite A
Vista, CA 92084
Prepared for :Western Sign & Awning
GENERAL NOTES
1.) DESIGN CODE : 2022 CBC
2.) DESIGN LOADS :ASCE 7-16
3.) WIND VELOCITY :
4.) PROVIDE PROTECTON AGAINST DISSIMILAR MATERIALS
5.) PROVIDE OPEN ENDS OF HOLLOW SECTIONS WITH FULLY WELDED CAP,
CAP THICKNESS TO BE SIMILAR TO HOLLOW SECTION THICKNESS.
6.) IN CASE OF CONFLICT BETWEEN ARCHITECTURAL/SHOP DRAWINGS &
THIS CALCULATION SET ( INCLUDING ANCHOR CALCULATION DRAWINGS ),
THIS CALCULATION SET SHALL GOVERN.
Prepared By:Cerenico G. Madrona, P.E., M.ASCE
7868 De Soto Ave.
Canoga Park, CA 91304
W: 818-453-0394 C: 818-667-1279
Email: eco@trimarengineering.com
96 MPH
5/27/2025
Job:Better Buzz - Menuboard Pg. 2
1465 E Vista Way, Suite A, Vista, CA 92084
Dead Load, D
Element Weight
Sign Cabinet 112 Lb
Pole 71 Lb
Total : 183 Lb
Risk Category =II
Exposure category (B, C or D) =C
Basic wind speed (3 sec. gust wind) V =96 mph
Topographic factor Kzt =1
Sign Height to grade, in feet =h
Vertical dimension, in feet =s
Horizontal dimension, in feet =B
Return corner horizontal dimension, in feet =Lr
Sign gross area, in square feet =As
Kh = velocity pressure exposure coefficient evaluated at height, h,(Tab. 27.3-1)
Kd = wind directionality factor. (Tab. 26.6-1)=0.85
Site Elevation =461.49 ft.
Ke = ground elevation factor. (Tab. 26.9-1)=1
Velocity pressure, qh = 0.00256 Kh Kzt Kd Ke V2 ( 26.10-1 )
where: G = gust effect factor. (Sec. 26.11, page 269). =0.85
Cf = net force coefficient. (Fig. 29.3-1, page 323)
h Kh s B s / h B / s Lr As Cf qh p
( PSF ) ( Psf )
Sign Cabinet 5.844 0.85 4.01 4.65 0.69 1.16 0.417 18.63 1.52 17.05 22.02
Pole 1.833 0.85 1.833 0.333 1.00 0.18 0.333 0.61 1.64 17.05 23.76
Moment arm to base Moment at base, M
( F t ) (Lb - F t )
Sign Cabinet 3.84 1576
Pole 1.008 15
Total :1590
Design based on 2022 CBC, ASCE 7-16
Design Loads
Wind Design Data
Design wind force, F = qh G Cf As
ELEMENT
425
ELEMENT Wind Force
F
410
15
Job:Better Buzz - Menuboard Pg. 3
1465 E Vista Way, Suite A, Vista, CA 92084
Job:Better Buzz - Menuboard Pg. 4
1465 E Vista Way, Suite A, Vista, CA 92084
Use ASCE 7, ASD Load combination 5: D + 0.6W :
Design forces:Wind Load, 0.6F = 255 Lb
Wind Moment, MW = 0.6M =954 Lb- Ft =11.45 Kip - in
Design Dead Load, D =183 Lb
Try : HSS 4 x 4 x 1/4 STEEL SQUARE HSS, A500 Gr. B Fy = 46 Ksi Fu = 58 Ksi
Geometric properties :
Wt = 12.21 plf h = 3.30 I = 7.8
A = 3.37 in^2 b = 3.30 Z = 4.69 in^3
Nom. t = 0.250 in. b / t = 14.2 S = 3.9
Design t = 0.233 h / t = 14.2 r = 1.52
C = 6.56
Check bending :
Check flange compactness :Limiting b / t ≤ 1.12 √ E / Fy =28.1 >14.2
Check flange slenderness :Limiting b / t ≤ 1.4 √ E / Fy =35.2 >14.2
Therefore flange is non-compact
Check web compactness :Limiting b / t ≤ 2.42 √ E / Fy =60.8 >14.2
Therefore web is compact
For compact web and flanges :
Mp = Fy Zx = 46 x 4.69 =215.74 kip-in = Mn
Available flexural strength = Mn/Ωb Ωb =1.67
Available flexural strength = 129.19 kip-in
Moment demand , M =11.45 kip-in <129.2 kip-in (Ok
USE : HSS 4 x 4 x 1/4 STEEL SQUARE HSS, A500 Gr. B Fy = 46 Ksi
Design Lateral Force, P = 0.6 F = 255 Lb
Lever arm to Base = Mw / P = 3.74 Ft.
Required Depth of Embedment, d = 0.5 A { 1 + √ [ 1 +( 4.36 h / A ) ] }
Footing Diameter =2.00 Ft
Soil Pressure =100 PSF/FT
S1 =100 * 2
S1 =212.67 PSF
A =2.34 P / ( S1 b )
A = ( 213 * 2.00 ) = 1.40 Ft
Embedment Depth =
Embedment Depth = 3.19 Ft
USE : 24 " Dia. x 3' - 3" Depth, Min. 2,500 psi Concrete Footing
/ 1.40 ) ) ) )
Design of Concrete Footing ( Nonconstrained )
* ( 3.19 / 3 )
( 2.34 * 255 ) /
( 0.5 * 1.4 ) * ( 1 + ( SQRT ( 1+( 4.36 * 3.74
Design of Pole
Job:Better Buzz - Menuboard Pg. 5
1465 E Vista Way, Suite A, Vista, CA 92084
USE Strength Load Combination 5 : 0.9D + 1.0W
F =425 Lb
0.9D =165 Lb
M =1590 Lb - Ft
See HILTI Profis Engineering calcs pages
USE : ( 4 ) 3/4" DIA. x 25" MIN. Embed. Depth,
Hex Head ASTM F1554 GR. 36 Galv. Steel
All- Thread Rod w/ Double Hex nut & washer at Bottom
ends on min. f'c = 2,500 psi Concrete Base
USE : 14-1/2" x 14-1/2" x 3/4" thk.
A36 Galv. Steel Base Plate
Base Anchor & Plate Design
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Menuboard Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
6
CM
eco@trimarengineering.com
5/27/2025
Specifier's comments: Better Buzz - Menuboard
1 Anchor Design
1.1 Input data
Anchor type and diameter: Hex Head ASTM F 1554 GR. 36 3/4
Item number: not available
Specification text:Æ 3/4 in Hex Head ASTM F 1554 GR. 36 with
25 in nominal embedment depth per Technical
data , cast in place installation per MPII,
Effective embedment depth: hef = 25.000 in.
Material: ASTM F 1554
Evaluation Service Report: Hilti Technical Data
Issued I Valid: - | -
Proof: Design Method ACI 318-19 / CIP
Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-19 Fig. R.17.7.2.1b)
Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.750 in.
Anchor plateCBFEM : lx x ly x t = 14.500 in. x 14.500 in. x 0.750 in.;
Profile: Square HSS (AISC), HSS4X4X.25; (L x W x T) = 4.000 in. x 4.000 in. x 0.250 in.
Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 39.000 in.
Reinforcement: tension: not present, shear: not present;
edge reinforcement: none or < No. 4 bar
CBFEM - The anchor calculation is based on a component-based Finite Element Method (CBFEM)
Geometry [in.] & Loading [lb, ft.lb]
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Menuboard Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
7
CM
eco@trimarengineering.com
5/27/2025
1.1.1 Design results
Case Description Forces [lb] / Moments [ft.lb]Seismic Max. Util. Anchor [%]
1 Combination 1 N = -165; Vx = 425; Vy = 0;
Mx = 0.000; My = 1,590.000; Mz = 0.000;
no 29
1.2 Load case/Resulting anchor forces
Anchor reactions [lb]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 1,359 107 107 6
2 0 106 106 -2
3 1,360 107 107 -6
4 0 106 106 2
Resulting tension force in (x/y)=(-4.750/0.002): 2,720 [lb]
Resulting compression force in (x/y)=(1.255/0.004): 3,040 [lb]
Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)
1.3 Tension load
Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status
Steel Strength*1,360 14,529 10 OK
Pullout Strength*1,360 9,156 15 OK
Concrete Breakout Failure**2,720 9,660 29 OK
Concrete Side-Face Blowout, direction y+*1,360 11,960 12 OK
* highest loaded anchor **anchor group (anchors in tension)
1.3.1 Steel Strength
Nsa [lb]f f Nsa [lb]Nua [lb]
19,372 0.750 14,529 1,360
1.3.2 Pullout Strength
Np [lb]y c,p l a f f Npn [lb]Nua [lb]
13,080 1.000 1 0.700 9,156 1,360
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Menuboard Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
8
CM
eco@trimarengineering.com
5/27/2025
1.3.3 Concrete Breakout Failure
ANc [in.2]ANc0 [in.2]ca,min [in.]cac [in.]y c,N hef [in.]
402.56 874.03 5.282 -1.000 9.855
ec1,N [in.]y ec1,N ec2,N [in.]y ec2,N y ed,N kcr
0.000 1.000 0.002 1.000 0.807 24
l a Nb [lb]f f Ncbg [lb]Nua [lb]
1.000 37,123 0.700 9,660 2,720
1.3.4 Concrete Side-Face Blowout, direction y+
ca1 [in.]Abrg [in.2]l a Nsb [lb]agroup s [in.]
5.282 0.65 1.000 17,086 1.000 -
NSbg [lb]f f NSbg [lb]Nua [lb]
17,086 0.700 11,960 1,360
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Menuboard Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
9
CM
eco@trimarengineering.com
5/27/2025
1.4 Shear load
Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status
Steel Strength*107 7,555 2 OK
Steel failure (with lever arm)*N/A N/A N/A N/A
Pryout Strength**425 40,045 2 OK
Concrete edge failure in direction y-**425 4,334 10 OK
* highest loaded anchor **anchor group (relevant anchors)
1.4.1 Steel Strength
Vsa [lb]f f Vsa [lb]Vua [lb]
11,623 0.650 7,555 107
1.4.2 Pryout Strength
ANc [in.2]ANc0 [in.2]ca,min [in.]kcp cac [in.]y c,N hef [in.]
402.56 111.60 5.282 2 -1.000 3.521
ec1,V [in.]y ec1,V ec2,V [in.]y ec2,V y ed,N kcr
0.000 1.000 0.000 1.000 1.000 24
l a Nb [lb]f f Vcpg [lb]Vua [lb]
1.000 7,929 0.700 40,045 425
1.4.3 Concrete edge failure in direction y-
le [in.]d0 [in.]c1 [in.]AVc [in.2]AVc0 [in.2]
6.000 0.750 5.282 158.97 125.55
y ed,V y parallel,V ec,V [in.]y ec,V y c,V y h,V
0.900 1.000 0.044 0.995 1.000 1.000
l a Vb [lb]f f Vcbg [lb]Vua [lb]
1.000 5,463 0.700 4,334 425
1.5 Combined tension and shear loads, per ACI 318-19 section 17.8
bN bV z Utilization bN,V [%]Status
0.282 0.098 5/3 15 OK
bNV = bz
N + bz
V <= 1
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Menuboard Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
10
CM
eco@trimarengineering.com
5/27/2025
1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA TR029,
etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum
required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• The equations presented in this report are based on imperial units. When inputs are displayed in metric units, the user should be aware that the
equations remain in their imperial format.
• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential
concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout
or pryout strength governs.
• For additional information about ACI 318 strength design provisions, please go to
https://viewer.joomag.com/profis-design-guide-us-en-summer-2021/0841849001625154758?short&/
• The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to elastic/plastic
displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment."
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
11
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Menuboard Base Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
11
CM
eco@trimarengineering.com
5/27/2025
Coordinates Anchor [in.]
Anchor x y c-x c+x c-y c+y
1 -4.750 -4.750 5.282 14.782 5.282 14.782
2 4.750 -4.750 14.782 5.282 5.282 14.782
3 -4.750 4.750 5.282 14.782 14.782 5.282
4 4.750 4.750 14.782 5.282 14.782 5.282
1.7 Installation data
Anchor type and diameter: Hex Head ASTM F 1554 GR.
36 3/4
Profile: Square HSS (AISC), HSS4X4X.25; (L x W x T) = 4.000 in. x 4.000 in. x
0.250 in.
Item number: not available
Hole diameter in the fixture: df = 0.812 in. Maximum installation torque: -
Plate thickness (input): 0.750 in. Hole diameter in the base material: - in.
Hole depth in the base material: 25.000 in.
Minimum thickness of the base material: 26.000 in.
Æ 3/4 in Hex Head ASTM F 1554 GR. 36 with 25 in nominal embedment depth per Technical data , cast in place installation per MPII
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:12
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Menuboard Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
12
2 Anchor plate design
2.1 Input data
Anchor plate:Shape: Rectangular
lx x ly x t = 14.500 in x 14.500 in x 0.750 in
Calculation: CBFEM
Material: ASTM A36; Fy = 36,000 psi; εlim = 5.00%
Anchor type and size:Hex Head ASTM F 1554 GR. 36 3/4, hef = 25.000 in
Anchor stiffness:The anchor is modeled considering stiffness values determined from load displacement curves tested in an
independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor
stiffness has a major impact on the load distribution results.
Design method:AISC and LRFD-based design using component-based FEM
Stand-off installation:eb = 0.000 in (No stand-off); t = 0.750 in
Profile:HSS4X4X.25; (L x W x T x FT) = 4.000 in x 4.000 in x 0.250 in x -
Material: ASTM A500 Gr.B Rect; Fy = 46,000 psi; εlim = 5.00%
Eccentricity x: 0.000 in
Eccentricity y: 0.000 in
Base material:Cracked concrete; 2500; fc,cyl = 2,500 psi; h = 39.000 in
Welds (profile to anchor plate):Type of redistribution: Plastic
Material: E70xx
Mesh size:Number of elements on edge: 8
Min. size of element: 0.394 in
Max. size of element: 1.969 in
2.2 Summary
Description Profile Anchor plate Concrete [%]
sEd [psi]ePl [%]sEd [psi]ePl [%]Hole bearing [%]
1 Combination 1 12,138 0.00 5,283 0.00 1 3
2.3 Anchor plate classification
Results below are displayed for the decisive load combinations: Combination 1
Anchor tension forces Equivalent rigid anchor plate (CBFEM)Component-based Finite Element Method
(CBFEM) anchor plate design
Anchor 1 884 lb 1,359 lb
Anchor 2 0 lb 0 lb
Anchor 3 884 lb 1,360 lb
Anchor 4 0 lb 0 lb
User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can be
applied.
2.4 Profile/Stiffeners/Plate
Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for critical
cross sections, which should be performed outside of PROFIS Engineering.
2.4.1 Equivalent stress and plastic strain
Part Load
combination
Material fy [psi]elim [%]sEd [psi]ePl [%]Status
Plate Combination 1 ASTM A36 36,000 5.00 5,283 0.00 OK
Profile Combination 1 ASTM A500 Gr.B 46,000 5.00 12,138 0.00 OK
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:13
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Menuboard Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
13
Part Load
combination
Material fy [psi]elim [%]sEd [psi]ePl [%]Status
Rect
Profile Combination 1 ASTM A500 Gr.B
Rect
46,000 5.00 9,360 0.00 OK
Profile Combination 1 ASTM A500 Gr.B
Rect
46,000 5.00 6,080 0.00 OK
Profile Combination 1 ASTM A500 Gr.B
Rect
46,000 5.00 6,153 0.00 OK
2.4.1.1 Equivalent stress
Results below are displayed for the decisive load combination: 1 - Combination 1
46,000 psi
0 psi
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:14
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Menuboard Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
14
2.4.1.2 Plastic strain
Results below are displayed for the decisive load combination: 1 - Combination 1
5.00%
0.00%
2.4.2 Plate hole bearing resistance, AISC 360-16 Section J3
Decisive load combination: 1 - Combination 1
Results
V [lb]FRn [lb]Utilization [%]Status
Anchor 1 107 58,725 1 OK
Anchor 2 106 58,725 1 OK
Anchor 3 107 58,725 1 OK
Anchor 4 106 58,725 1 OK
2.5 Concrete
Decisive load combination: 1 - Combination 1
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:15
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Menuboard Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
15
2.5.1 Compression in concrete under the anchor plate
127 psi
0 psi
2.5.2 Concrete block compressive strength resistance check, AISC 360-16 Section J8
Results
Load combination Fp [psi]s [psi]Utilization [%]Status
Combination 1 2,299 50 3 OK
2.6 Symbol explanation
elim Limit plastic strain
ePl Plastic strain from CBFEM results
Fp Concrete block design bearing strength
fy Yield strength
s Average stress in concrete
sEd Equivalent stress
FRn Factored resistance
V Resultant of shear forces Vy, Vz in bolt.
2.7 Warnings
●By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability and
adequacy for your specific jurisdiction and project requirements.
●The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory. Please
note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution results.
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:16
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Menuboard Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
16
3 Summary of results
Design of the anchor plate, anchors, welds and other elements are based on CBFEM (component based finite element method) and AISC.
Load combination Max. utilization Status
Anchors Combination 1 29%OK
Anchor plate Combination 1 15%OK
Concrete Combination 1 3%OK
Profile Combination 1 27%OK
Fastening meets the design criteria!
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:17
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Menuboard Base Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
17
4 Remarks; Your Cooperation Duties
●Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to
using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put
in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret
norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a
specific application.
●You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not
use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in
each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.
TRIMAR ENGINEERING
Structural Calculation
Project :Better Buzz - Pole Mounted Clearance Bar
Project address:1465 E Vista Way, Suite A
Vista, CA 92084
Prepared for :Western Sign & Awning
GENERAL NOTES
1.) DESIGN CODE : 2022 CBC
2.) DESIGN LOADS :ASCE 7-16
3.) WIND VELOCITY :
4.) PROVIDE PROTECTON AGAINST DISSIMILAR MATERIALS
5.) PROVIDE OPEN ENDS OF HOLLOW SECTIONS WITH FULLY WELDED CAP,
CAP THICKNESS TO BE SIMILAR TO HOLLOW SECTION THICKNESS.
6.) IN CASE OF CONFLICT BETWEEN ARCHITECTURAL/SHOP DRAWINGS &
THIS CALCULATION SET ( INCLUDING ANCHOR CALCULATION DRAWINGS ),
THIS CALCULATION SET SHALL GOVERN.
Prepared By:Cerenico G. Madrona, P.E., M.ASCE
7868 De Soto Ave.
Canoga Park, CA 91304
W: 818-453-0394 C: 818-667-1279
Email: eco@trimarengineering.com
96 MPH
5/27/2025
Job:Better Buzz - Pole Mounted Clearance Bar Pg. 2
1465 E Vista Way, Suite A, Vista, CA 92084
Dead Load, D
Element
Pole 126 Lb
Horiz. Pole & Clearance Bar 93 Lb
Total : 219 Lb
Risk Category =II
Exposure category (B, C or D) =C
Basic wind speed (3 sec. gust wind) V =96 mph
Topographic factor Kzt =1
Sign Height to grade, in feet =h
Vertical dimension, in feet =s
Horizontal dimension, in feet =B
Return corner horizontal dimension, in feet =Lr
Sign gross area, in square feet =As
Kh = velocity pressure exposure coefficient evaluated at height, h,(Tab. 27.3-1)
Kd = wind directionality factor. (Tab. 26.6-1)=0.85
Site Elevation =461.49 ft.
Ke = ground elevation factor. (Tab. 26.9-1)=1
Velocity pressure, qh = 0.00256 Kh Kzt Kd Ke V2 ( 26.10-1 )
where: G = gust effect factor. (Sec. 26.11, page 269). =0.85
Cf = net force coefficient. (Fig. 29.3-1, page 323)
h Kh s B s / h B / s Lr As Cf qh p
( PSF ) ( Psf )
Pole, Vertical 10.333 0.85 10.333 0.333 1.00 0.03 0.333 3.44 1.80 17.05 26.08
Pole, Horizontal - Case A 10.333 0.85 0.333 6.604 0.03 19.83 0.333 2.20 1.90 17.05 27.53
Clearance Bar - Case A 8.833 0.85 0.333 6.00 0.04 18.02 0.167 2.00 1.89 17.05 27.38
F Lever Arm to Base Moment Lever Arm to Torsion
( Lb )Base, Ft MW ( Lb - Ft ) Pole CL ( Lb - Ft )
Pole, Vertical 89.74 5.68 510 0.00 0
Pole, Horizontal - Case A 60.54 10.17 616 3.55 215
Clearance Bar - Case A 54.71 8.67 474 3.85 211
Total : 205.0 1600 426
Asi Distance Cf pi ( Psf )Torsion
(Lb - F t )
Pole, Horizontal - Case C 0.111 0.30 3.048 44 4.9 10.17 50 6.60 32
0.111 0.70 2.589 38 4.2 10.17 43 6.27 26
0.111 1.00 1.989 29 3.2 10.17 33 5.94 19
0.111 1.30 1.575 23 2.6 10.17 26 5.60 14
0.111 1.70 1.457 21 2.3 10.17 24 5.27 12
0.555 3.30 0.943 14 7.8 10.17 79 4.27 33
1.090 6.60 0.550 8 8.7 10.17 89 1.80 16
Total :2.20 34 343 153
Weight
ELEMENT Wind Force, F Moment arm Moment Torsion arm
Design based on 2022 CBC, ASCE 7-16
Design Loads
Wind Design Data
Design wind force, F = qh G Cf As
ELEMENT
ELEMENT
F to base ( F t ) at base (Lb - F t ) to pole ( F t )
Job:Better Buzz - Pole Mounted Clearance Bar Pg. 3
1465 E Vista Way, Suite A, Vista, CA 92084
Asi Distance Cf pi ( Psf )Torsion
(Lb - F t )
Clearance Bar - Case C 0.111 0.30 3.468 50 5.6 8.67 48 6.63 37
0.111 0.70 2.592 38 4.2 8.67 36 6.29 26
0.111 1.00 1.992 29 3.2 8.67 28 5.96 19
Total :0.111 1.30 1.555 23 2.5 8.67 22 5.63 14
0.111 1.70 1.428 21 2.3 8.67 20 5.29 12
0.555 3.30 0.931 13 7.5 8.67 65 4.29 32
0.888 6.00 0.550 8 7.1 8.67 61 2.13 15
Total :2.00 32 280 156
F to base ( F t ) at base (Lb - F t ) to pole ( F t )
ELEMENT Wind Force, F Moment arm Moment Torsion arm
Job:Better Buzz - Pole Mounted Clearance Bar Pg. 4
1465 E Vista Way, Suite A, Vista, CA 92084
By inspection, Case - A governs for horiz. pole & clearance bar wind forces.
USE ASD Load Combination 4 : 1.0D + 0.6W
Sign dead load, D =219 Lb =0.219 Kip
Horiz. Pole & Clearance Bar DL =93 Lb =0.093 Kip
Distance from geometric center of horiz. Pole & bar to pole base, d1 =45.60 in.
Dead load moment = D * d1 = My =4.224 Kip- in
Wind load = 0.6 * F =123 Lb =0.123 Kip
Wind load moment = Mx = 0.6Mw =960 Ft - Lb =11.52 Kip- in
0.6 x Torsion =255 Ft - Lb =3.06 Kip- in
Try : HSS 4 x 4 x 1/4 STEEL SQUARE HSS, A500 Gr. B Fy = 46 Ksi Fu = 58 Ksi
Geometric properties :
Wt = 12.21 plf h = 3.30 I = 7.8
A = 3.37 in^2 b = 3.30 Z = 4.69 in^3
Nom. t = 0.250 in. b / t = 14.2 S = 3.9
Design t = 0.233 h / t = 14.2 r = 1.52
C = 6.56
Check bending :
Check flange compactness :Limiting b / t ≤ 1.12 √ E / Fy =28.1 >14.2
Check flange slenderness :Limiting b / t ≤ 1.4 √ E / Fy =35.2 >14.2
Therefore flange is non-compact
Check web compactness :Limiting b / t ≤ 2.42 √ E / Fy =60.8 >14.2
Therefore web is compact
For compact web and flanges :
Mp = Fy Zx = 46 x 4.69 =215.74 kip-in = Mn
Available flexural strength = Mn/Ωb Ωb =1.67
Available flexural strength = 129.19 kip-in
Moment demand , My =4.22 kip-in <129.2 kip-in (Ok
Moment demand , Mx =11.5 kip-in <129.2 kip-in (Ok
Check Torsion capacity: Tn = Fcr C
Limiting h / t ≤ 2.45 √ E / Fy =61.5
Limiting h / t ≤ 3.07 √ E / Fy =77.1
When h / t ≤ 2.45 √ E / Fy : Fcr = 0.6 Fy =27.6
When 2.45 √ E / Fy < h / t ≤ 3.07 √ E / Fy : Fcr = 0.6 Fy [ 2.45 √ E / Fy ] / ( h / t ) =119.6
When 3.07 √ E / Fy < h / t ≤ 260 : Fcr = 0.458 π2E / ( h/t )2 =650.11
Tn =181 ΩT =1.67 Tc = Tn / ΩT =108 kip - in.
Tr =3.06 < 108 kip - in. ( Ok )
Tr / Tc = 0.028 < 0.20
Check Axial Load capacity:
Required Axial Strength, Pr =0.219 kip
K= 2.0 L = 124 in KL/r = 163.2 4.71√(E / Fy) = 118.3
KL/r > 118.3 Therefore Fcr = 0.877Fe Fe = ∏2 E / (KL/r)2 =10.75 Fcr = 9.43
Pn = Fcr Ag =31.78 Pn / Ω =19.03 kips >0.219 kips (Ok
Pr / Pc = 0.01 < 0.20
Interaction = Pr / 2Pc + ( Mr / Mc ) ≤ 1.0 =0.13 < 1.0 (Ok)
USE : HSS 4 x 4 x 1/4 STEEL SQUARE HSS, A5 Fy = 46 Ksi
Design of Pole
Job:Better Buzz - Pole Mounted Clearance Bar Pg. 5
1465 E Vista Way, Suite A, Vista, CA 92084
Moment demand , My =4.2 Kip- in
Moment demand , Mx =11.5 Kip- in
Resultant Moment demand , M = √ ( Mx2 + My2 ) =12.3 Kip- in =1022.5 Ft - Lb
Desi n Lateral Force, P = 0.6F =205 Lbs
Distance from ground surface to point of application of "P", h = M / P =4.99 Ft.
Required Depth of Embedment, d = 0.5 A { 1 + √ [ 1 +( 4.36 h / A ) ] }
Footing Diameter, b =2.00 Ft
Soil Pressure =100 PSF/FT
S1 =100 * 2
S1 =208.67 PSF
A =2.34 P / ( S1 b )
A = ( 209 * 2.00 ) = 1.15 Ft
Embedment Depth =
Embedment Depth = 3.14 Ft
USE : 24 " Dia. X 3' - 3" Depth, Min. 2,500 psi Concrete Footing
USE Strength Load Combination 4 : 1.2D + 1.0W
F =205 Lb
1.2D =263 Lb
Mx =1600 Lb - Ft
My =352 Lb - Ft
Torsion =426 Lb - Ft
See HILTI Profis Engineering calcs pages
USE : ( 4 ) 3/4" DIA. x 25" MIN. Embed. Depth,
Hex Head ASTM F1554 GR. 36 Galv. Steel
All- Thread Rod w/ Double Hex nut & washer at Bottom
ends on min. f'c = 2,500 psi Concrete Base
USE : 14-1/2" x 14-1/2" x 3/4" thk.
Design of Concrete Footing ( Nonconstrained )
Base Anchor & Plate Design
A36 Galv. Steel Base Plate
* ( 3.13 / 3 )
( 2.34 * 205 ) /
( 0.5 * 1.1 ) * ( 1 + ( SQRT ( 1+( 4.36 * 5.0 / 1.15 ) ) ) )
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Clearance Bar Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
6
CM
eco@trimarengineering.com
5/27/2025
Specifier's comments: Better Buzz - Pole Mounted Clearance Bar
1 Anchor Design
1.1 Input data
Anchor type and diameter: Hex Head ASTM F 1554 GR. 36 3/4
Item number: not available
Specification text:Æ 3/4 in Hex Head ASTM F 1554 GR. 36 with
25 in nominal embedment depth per Technical
data , cast in place installation per MPII,
Effective embedment depth: hef = 25.000 in.
Material: ASTM F 1554
Evaluation Service Report: Hilti Technical Data
Issued I Valid: - | -
Proof: Design Method ACI 318-19 / CIP
Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-19 Fig. R.17.7.2.1b)
Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.750 in.
Anchor plateCBFEM : lx x ly x t = 14.500 in. x 14.500 in. x 0.750 in.;
Profile: Square HSS (AISC), HSS4X4X.25; (L x W x T) = 4.000 in. x 4.000 in. x 0.250 in.
Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 39.000 in.
Reinforcement: tension: not present, shear: not present;
edge reinforcement: none or < No. 4 bar
CBFEM - The anchor calculation is based on a component-based Finite Element Method (CBFEM)
Geometry [in.] & Loading [lb, ft.lb]
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Clearance Bar Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
7
CM
eco@trimarengineering.com
5/27/2025
1.1.1 Design results
Case Description Forces [lb] / Moments [ft.lb]Seismic Max. Util. Anchor [%]
1 Combination 1 N = -263; Vx = 205; Vy = 0;
Mx = 352.000; My = 1,600.000; Mz = 426.000;
no 30
1.2 Load case/Resulting anchor forces
Anchor reactions [lb]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 1,199 226 185 -129
2 0 229 186 133
3 1,527 162 -83 -140
4 0 160 -84 136
Resulting tension force in (x/y)=(-4.750/0.570): 2,726 [lb]
Resulting compression force in (x/y)=(1.210/-0.932): 3,123 [lb]
Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)
1.3 Tension load
Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status
Steel Strength*1,527 14,529 11 OK
Pullout Strength*1,527 9,156 17 OK
Concrete Breakout Failure**2,726 9,302 30 OK
Concrete Side-Face Blowout, direction y+*1,527 11,960 13 OK
* highest loaded anchor **anchor group (anchors in tension)
1.3.1 Steel Strength
Nsa [lb]f f Nsa [lb]Nua [lb]
19,372 0.750 14,529 1,527
1.3.2 Pullout Strength
Np [lb]y c,p l a f f Npn [lb]Nua [lb]
13,080 1.000 1 0.700 9,156 1,527
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Clearance Bar Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
8
CM
eco@trimarengineering.com
5/27/2025
1.3.3 Concrete Breakout Failure
ANc [in.2]ANc0 [in.2]ca,min [in.]cac [in.]y c,N hef [in.]
402.56 874.03 5.282 -1.000 9.855
ec1,N [in.]y ec1,N ec2,N [in.]y ec2,N y ed,N kcr
0.000 1.000 0.570 0.963 0.807 24
l a Nb [lb]f f Ncbg [lb]Nua [lb]
1.000 37,123 0.700 9,302 2,726
1.3.4 Concrete Side-Face Blowout, direction y+
ca1 [in.]Abrg [in.2]l a Nsb [lb]agroup s [in.]
5.282 0.65 1.000 17,086 1.000 -
NSbg [lb]f f NSbg [lb]Nua [lb]
17,086 0.700 11,960 1,527
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Clearance Bar Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
9
CM
eco@trimarengineering.com
5/27/2025
1.4 Shear load
Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status
Steel Strength*229 7,555 4 OK
Steel failure (with lever arm)*N/A N/A N/A N/A
Pryout Strength*229 10,011 3 OK
Concrete edge failure in direction x+**459 2,933 16 OK
* highest loaded anchor **anchor group (relevant anchors)
1.4.1 Steel Strength
Vsa [lb]f f Vsa [lb]Vua [lb]
11,623 0.650 7,555 229
1.4.2 Pryout Strength
ANc [in.2]ANc0 [in.2]ca,min [in.]kcp cac [in.]y c,N hef [in.]
100.64 111.60 5.282 2 -1.000 3.521
ec1,V [in.]y ec1,V ec2,V [in.]y ec2,V y ed,N kcr
0.000 1.000 0.000 1.000 1.000 24
l a Nb [lb]f f Vcp [lb]Vua [lb]
1.000 7,929 0.700 10,011 229
1.4.3 Concrete edge failure in direction x+
le [in.]d0 [in.]c1 [in.]AVc [in.2]AVc0 [in.2]
6.000 0.750 5.282 158.97 125.55
y ed,V y parallel,V ec,V [in.]y ec,V y c,V y h,V
0.900 1.000 3.848 0.673 1.000 1.000
l a Vb [lb]f f Vcbg [lb]Vua [lb]
1.000 5,463 0.700 2,933 459
1.5 Combined tension and shear loads, per ACI 318-19 section 17.8
bN bV z Utilization bN,V [%]Status
0.293 0.156 5/3 18 OK
bNV = bz
N + bz
V <= 1
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Clearance Bar Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
10
CM
eco@trimarengineering.com
5/27/2025
1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA TR029,
etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum
required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• The equations presented in this report are based on imperial units. When inputs are displayed in metric units, the user should be aware that the
equations remain in their imperial format.
• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential
concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout
or pryout strength governs.
• For additional information about ACI 318 strength design provisions, please go to
https://viewer.joomag.com/profis-design-guide-us-en-summer-2021/0841849001625154758?short&/
• The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to elastic/plastic
displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment."
www.hilti.com
Hilti PROFIS Engineering 3.1.15
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
11
Company:
Address:
Phone I Fax:
Design:
Fastening point:
Trimar Engineering
7868 De Soto Avenue
818-453-0394 |
Clearance Bar Anchor Design
Top of Footing
Page:
Specifier:
E-Mail:
Date:
11
CM
eco@trimarengineering.com
5/27/2025
Coordinates Anchor [in.]
Anchor x y c-x c+x c-y c+y
1 -4.750 -4.750 5.282 14.782 5.282 14.782
2 4.750 -4.750 14.782 5.282 5.282 14.782
3 -4.750 4.750 5.282 14.782 14.782 5.282
4 4.750 4.750 14.782 5.282 14.782 5.282
1.7 Installation data
Anchor type and diameter: Hex Head ASTM F 1554 GR.
36 3/4
Profile: Square HSS (AISC), HSS4X4X.25; (L x W x T) = 4.000 in. x 4.000 in. x
0.250 in.
Item number: not available
Hole diameter in the fixture: df = 0.812 in. Maximum installation torque: -
Plate thickness (input): 0.750 in. Hole diameter in the base material: - in.
Hole depth in the base material: 25.000 in.
Minimum thickness of the base material: 26.000 in.
Æ 3/4 in Hex Head ASTM F 1554 GR. 36 with 25 in nominal embedment depth per Technical data , cast in place installation per MPII
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:12
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Clearance Bar Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
12
2 Anchor plate design
2.1 Input data
Anchor plate:Shape: Rectangular
lx x ly x t = 14.500 in x 14.500 in x 0.750 in
Calculation: CBFEM
Material: ASTM A36; Fy = 36,000 psi; εlim = 5.00%
Anchor type and size:Hex Head ASTM F 1554 GR. 36 3/4, hef = 25.000 in
Anchor stiffness:The anchor is modeled considering stiffness values determined from load displacement curves tested in an
independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor
stiffness has a major impact on the load distribution results.
Design method:AISC and LRFD-based design using component-based FEM
Stand-off installation:eb = 0.000 in (No stand-off); t = 0.750 in
Profile:HSS4X4X.25; (L x W x T x FT) = 4.000 in x 4.000 in x 0.250 in x -
Material: ASTM A500 Gr.B Rect; Fy = 46,000 psi; εlim = 5.00%
Eccentricity x: 0.000 in
Eccentricity y: 0.000 in
Base material:Cracked concrete; 2500; fc,cyl = 2,500 psi; h = 39.000 in
Welds (profile to anchor plate):Type of redistribution: Plastic
Material: E70xx
Mesh size:Number of elements on edge: 8
Min. size of element: 0.394 in
Max. size of element: 1.969 in
2.2 Summary
Description Profile Anchor plate Concrete [%]
sEd [psi]ePl [%]sEd [psi]ePl [%]Hole bearing [%]
1 Combination 1 14,218 0.00 5,834 0.00 1 3
2.3 Anchor plate classification
Results below are displayed for the decisive load combinations: Combination 1
Anchor tension forces Equivalent rigid anchor plate (CBFEM)Component-based Finite Element Method
(CBFEM) anchor plate design
Anchor 1 738 lb 1,199 lb
Anchor 2 0 lb 0 lb
Anchor 3 1,013 lb 1,527 lb
Anchor 4 0 lb 0 lb
User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can be
applied.
2.4 Profile/Stiffeners/Plate
Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for critical
cross sections, which should be performed outside of PROFIS Engineering.
2.4.1 Equivalent stress and plastic strain
Part Load
combination
Material fy [psi]elim [%]sEd [psi]ePl [%]Status
Plate Combination 1 ASTM A36 36,000 5.00 5,834 0.00 OK
Profile Combination 1 ASTM A500 Gr.B 46,000 5.00 14,218 0.00 OK
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:13
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Clearance Bar Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
13
Part Load
combination
Material fy [psi]elim [%]sEd [psi]ePl [%]Status
Rect
Profile Combination 1 ASTM A500 Gr.B
Rect
46,000 5.00 11,621 0.00 OK
Profile Combination 1 ASTM A500 Gr.B
Rect
46,000 5.00 6,184 0.00 OK
Profile Combination 1 ASTM A500 Gr.B
Rect
46,000 5.00 7,611 0.00 OK
2.4.1.1 Equivalent stress
Results below are displayed for the decisive load combination: 1 - Combination 1
46,000 psi
0 psi
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:14
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Clearance Bar Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
14
2.4.1.2 Plastic strain
Results below are displayed for the decisive load combination: 1 - Combination 1
5.00%
0.00%
2.4.2 Plate hole bearing resistance, AISC 360-16 Section J3
Decisive load combination: 1 - Combination 1
Results
V [lb]FRn [lb]Utilization [%]Status
Anchor 1 226 58,725 1 OK
Anchor 2 229 58,725 1 OK
Anchor 3 162 58,725 1 OK
Anchor 4 160 58,725 1 OK
2.5 Concrete
Decisive load combination: 1 - Combination 1
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:15
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Clearance Bar Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
15
2.5.1 Compression in concrete under the anchor plate
147 psi
0 psi
2.5.2 Concrete block compressive strength resistance check, AISC 360-16 Section J8
Results
Load combination Fp [psi]s [psi]Utilization [%]Status
Combination 1 2,614 53 3 OK
2.6 Symbol explanation
elim Limit plastic strain
ePl Plastic strain from CBFEM results
Fp Concrete block design bearing strength
fy Yield strength
s Average stress in concrete
sEd Equivalent stress
FRn Factored resistance
V Resultant of shear forces Vy, Vz in bolt.
2.7 Warnings
●By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability and
adequacy for your specific jurisdiction and project requirements.
●The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory. Please
note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution results.
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:16
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Clearance Bar Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
16
3 Summary of results
Design of the anchor plate, anchors, welds and other elements are based on CBFEM (component based finite element method) and AISC.
Load combination Max. utilization Status
Anchors Combination 1 30%OK
Anchor plate Combination 1 17%OK
Concrete Combination 1 3%OK
Profile Combination 1 31%OK
Fastening meets the design criteria!
Hilti PROFIS Engineering 3.1.15
www.hilti.com
Company:Trimar Engineering Page:17
Address:7868 De Soto Avenue Specifier:CM
Phone I Fax:818-453-0394 |E-Mail:eco@trimarengineering.com
Design:Clearance Bar Anchor Design Date:5/27/2025
Fastening point:Top of Footing
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
17
4 Remarks; Your Cooperation Duties
●Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to
using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put
in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret
norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a
specific application.
●You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not
use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in
each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.
VICINITY MAP
PROJECT INFORMATION SHEET INDEX
AN
D
G
E
N
E
R
A
L
N
O
T
E
S
TI
T
L
E
S
H
E
E
T
,
P
R
O
J
E
C
T
I
N
F
O
R
M
A
T
I
O
N
T1.1
PROJECT TEAM
DEFERRED/ SEPARATE SUBMITTAL
TENANT
KEVIN MACDONALD
801 UNIVERSITY AVENUE
SAN DIEGO, CA 92103
EMAIL: kevin.macdonald@betterbuzzcoffee.com
ARCHITECT
AMOR ARCHITECTURAL CORPORATION
9483 HAVEN AVENUE, SUITE 100
RANCHO CUCAMONGA, CA 91730
CONTACT:BILL BEEBE
PHONE: (909) 259-9971 EXT-102
FAX: (909) 944-8409
PHONE:bbeebe@amorarch.com
STRUCTURAL
LOVELACE ENGINEERING
10509 VISTA SORRENTO PKWY, SUITE 102,
SAN DIEGO, CA 92121
CONTACT:ALLEN LACTAOEN
PHONE: (858) 535-9111 EXT-107
EMAIL: alactaoen@lovelaceeng.com
MECHANICAL, PLUMBING,
ELECTRICAL
RIVAS DESIGN CONSULTANTS,LLC
CONTACT: CARLOS RIVAS
PHONE:(909) 997-0905
EMAIL:carlos@rivasdesignconsultants.com
NEW SHELL BUILDING & TENANT IMPROVEMENT
1601 N BRISTOL ST,
SANTA ANA, CA 92706
PROJECT ADDRESS: 1601 N BRISTOL ST,
SANTA ANA, CA 92706
PROPERTY ASSESSOR'S
PARCEL NUMBER (APN):405-252-21
ZONING:C-2, GENERAL COMMERCIAL
LOT/PARCEL AREA:18,814 S.F. (0.4319 Ac.)
CURRENT BUILDING CODE:ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES
INCLUDING LOCAL AMENDMENTS:
2022 CA BUILDING CODE 2022 CA ELECTRICAL CODE
2022 CA MECH CODE 2022 CA ENERGY CODE
2022 CA PLUMBING CODE 2022 CA FIRE CODE
ACCESSIBILITY CODE, 2022 CALIFORNIA BUILDING CODE
(TITLE 24, PART 2)
2022 CA GREEN BUILDING CODE
BUILDING SUMMARY
OCCUPANCY CLASSIFICATION:TENANT SPACE: RESTAURANT (GROUP B OCCUPANCY)
TYPE OF CONSTRUCTION: TYPE V-B NON RATED, NON-SPRINKLERED
NO. OF FLOORS:1
GROSS FLOOR AREA: 1,878 SF APPROX.
BUILDING AREA: 1,753 SF
TRASH ENCLOUSRE: 125 SF
TOTAL AREA:1,878 SF
AREA JUSTIFICATION:B OCCUPANCY, TYPE V-B
PER TABLE 601 FIRE RESISTANCE NOT REQUIRED
MAX ALLOWABLE AREA = 9,000 SF (1,878 SF; COMPLIED)
TENANT SPACE IS PROVIDED WITH 3 EXITS.
BUILDING GROSS AREA: 1,753 SF
BUILDING NET AREA: 1,634 SF
TRASH ENCLOUSRE: 125 SF
OCCUPANTS BASED ON SEATING/ + EMPLOYEES = 47
MAX. 3 EMPLOYEES PER SHIFT
1 RESTROOM/S REQUIRED AND PROVIDED
NUMBER OF FLOORS: SINGLE STORY
BUILDING HEIGHT:±21'-6"
MAX. ALLOWABLE BLDG HEIGHT:40'-0" (PER TABLE 504.3)
THE FOLLOWING ITEMS ARE TO BE SUBMITTED TO THE BUILDING DEPARTMENT FOR
REVIEW AND APPROVAL PRIOR TO INSTALLATION:
·BUILDING AND SITE SIGNAGE UNDER SEPARATE PERMIT
·DRIVE-THROUGH ELEMENTS UNDER SEPARATE PERMIT
·SITEWORK (GRADING/DRAINAGE, AC PAVING, LANDSCAPING, SITE LIGHTING,
CONCRETE CURBING) UNDER SEPARATE PERMIT
·EV CHARGING STATION EQUIPMENT
·METAL CANOPY UNDER SEPARATE PERMIT
N
PROJECT
SITE
BUILDING AND SAFETY NOTES
a. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE FOOT CLEAR AND UNOBSTRUCTED
ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES,
TRANSFORMER, VAULT, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE
LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY
POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO
COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES.
b. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE
ON THE DOWNSTREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE
EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (INCLUDES
COMMERCIAL ADDITIONS AND TI WORK OVER $10,000.) (SEPARATE PLUMBING PERMIT IS
REQUIRED).(PER ORDINANCE 170,158)
c. PROVIDE ULTRA-LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING
SHOWER HEAD AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION.
d. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE
AVAILABLE AT THE JOB SITE.
1.ALL CONTRACTORS AND SUBCONTRACTORS WILL THOROUGHLY FAMILIARIZE
THEMSELVES WITH THESE CONSTRUCTION DOCUMENTS AND WILL VERIFY EXISTING
SITE AND CONDITIONS PRIOR TO SUBMITTING A BID. ALL SUBCONTRACTORS WILL
PROVIDE ALL LABOR, SUPERVISION, AND MATERIALS OF EVERY TYPE WHICH MAY BE
NECESSARY FOR A SUCCESSFUL COMPLETION. ALL WORK TO BE PERFORMED IN A
GOOD AND WORKMANLIKE MANNER ACCORDING TO THE TRUE INTENT AND MEANING
OF THE DRAWINGS AND SPECIFICATIONS.
2.HVAC, PLUMBING AND ELECTRICAL DRAWINGS ARE INCLUDED IN, AND NOT
SUPPLEMENTARY TO, THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF EACH CONTRACTOR TO CHECK THE ARCHITECTURAL DRAWINGS
BEFORE INSTALLATION OF THEIR WORK. ANY DISCREPANCY BETWEEN THE
ARCHITECTURAL AND OTHER DRAWINGS SHALL BE BROUGHT TO THE ARCHITECT'S
ATTENTION BY THE CONTRACTOR FOR WRITTEN AND GRAPHIC CLARIFICATION.
3.THE CONTRACTOR SHALL FOCUS SPECIAL ATTENTION ON A FIELD REVIEW OF THE
EXISTING SITE IN WRITING PRIOR TO CONSTRUCTION. ANY CONDITIONS THAT ARE
FOUND TO BE INCONSISTENT WITH THESE DOCUMENTS OR WHERE THE INTENT IS IN
DOUBT SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR
RESOLUTION PRIOR TO BID SUBMITTAL. CONTRACTOR SHALL NOT RELY UPON ORAL
COMMUNICATIONS; ALL COMMUNICATIONS MUST BE IN WRITTEN OR GRAPHIC FORMAT.
4.REVISIONS TO WORK OR PLANS MUST BE APPROVED BY THE CITY AND BY LL / OR
LOCAL JURISDICTION's INSPECTION SERVICES PRIOR TO IMPLEMENTATION. ANY
ADDITIONS OR CHANGES TO WORK MUST BE AUTHORIZED IN WRITING BY THE
ARCHITECT AND OWNER. NO ALTERATIONS WILL BE MADE ON THIS PROJECT EXCEPT
UPON WRITTEN ORDER BY USING PREDETERMINED ARCHITECT SUPPLEMENTAL
INSTRUCTIONS, CHANGE ORDER OR CONSTRUCTION CHANGE DIRECTIVES.
5.CONTRACTOR IS RESPONSIBLE FOR THE MORE COSTLY AND TIME CONSUMING
RESOLUTION ON ALL CONFLICTING INFORMATION PRESENTED ON THE PLANS, OR
BETWEEN THE EXISTING CONDITIONS AND THE PLANS.
6.IF A CONFLICT OCCURS BETWEEN THE DESIGN DRAWINGS AND SPECIFICATIONS,
PROMPTLY NOTIFY THE ARCHITECT IN WRITING. AT THAT POINT, A WRITTEN
INTERPRETATION WILL BE MADE BY THE ARCHITECT AND SAID WRITTEN DECISION
SHALL BE CONSIDERED PART OF THE CONTRACT DOCUMENTS.
7.THIS ARCHITECT WILL NOT HAVE CONTROL OF, AND WILL NOT BE RESPONSIBLE FOR,
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR
SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK ON THIS
PROJECT OR FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR,
OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK ON THIS SITE, NOR FOR
THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE
INTENT OF THE CONTRACT AND OR CONSTRUCTION DOCUMENTS.
8.ALL CONTRACTORS WILL PROVIDE ADEQUATE BRACING AND / OR SHORING TO INSURE
STRUCTURAL STABILITY OF THE BUILDING AND ALL RELATED BUILDING COMPONENTS,
I.E.; STRUCTURAL WALLS, INTERIOR WALL ASSEMBLIES, ETC. DURING THE
CONSTRUCTION PHASE OF THIS PROJECT.
9.WORK WILL BE COORDINATED WITH ALL TRADES IN ORDER TO AVOID INTERFERENCE
AND AVOID OMISSIONS.
10.UNLESS NOTED OTHERWISE, ALL MATERIALS USED WILL BE NEW AND BEAR U.L.
LABELS WHERE REQUIRED AND MEET APPROPRIATE N.E.M.A. OR OTHER INDUSTRY
STANDARDS.
11.LAYOUT ALL PARTITIONS AND CABINETS BEFORE BEGINNING CONSTRUCTION TO
PREVENT ERRORS BY DISCREPANCY. ALL DRYWALL PARTITIONS AND CABINETS WILL
BE INSTALLED AS NOTED ON THE DRAWINGS. IF APPLICABLE, GENERAL CONTRACTOR
MUST OBTAIN RESOLUTION FROM ARCHITECT FOR ANY DISCREPANCIES PRIOR TO
CONSTRUCTION OF WALL PARTITIONS AND CABINETS.
12.EACH SUBCONTRACTOR WILL AMEND AND MAKE GOOD AT THEIR OWN COST, ANY
DEFECTS OR OTHER FAULTS IN THEIR WORKMANSHIP AND/OR THEIR SUPPLIED
MATERIALS.
13.VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO ORDERING, CUTTING AND / OR
INSTALLING MATERIAL, PRODUCT OR EQUIPMENT. IN THE EVENT OF ANY
DISCREPANCIES, CONTACT THE ARCHITECT FOR WRITTEN AND / OR GRAPHIC
DIRECTION PRIOR TO PROCEEDING WITH THAT WORK.
14.CONTRACTOR SHALL NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES.
IN THE EVENT OF OMISSION OF NECESSARY DIMENSIONS OR INFORMATION,
CONTRACTOR SHALL NOTIFY THE ARCHITECT. FIGURED AND CALCULATED DIMENSION
TAKE PRECEDENCE OVER SCALED MEASUREMENTS. DETAILED DRAWINGS AND
LARGER SCALE DRAWINGS TYPICALLY TAKES PRECEDENCE OVER SMALLER SCALE
DRAWINGS VERIFY WITH ARCHITECT. ALL PLAN DETAILS AND WALL SECTIONS ARE
ASSUMED TO BE TYPICAL CONDITIONS UNLESS DETAILED OR NOTED OTHERWISE.
15.PROVIDE SUFFICIENT BLOCKING IN STUD WALLS TO SUPPORT ALL ITEMS OR
EQUIPMENT SHOWN OR SPECIFIED TO BE ATTACHED TO THE WALLS. PROVIDE
ADDITIONAL STRUCTURAL SUPPORT (ANGLES, CHANNELS, ETC.) WITHIN WALLS WHERE
THE WEIGHT OF ATTACHED ITEMS OR EQUIPMENT IS TOO GREAT TO BE SUPPORTED
BY METAL STUDS. PROVIDE BLOCKING FOR OWNER FURNISHED OR INSTALLED ITEMS.
16.WEATHER CONDITIONS: CONTRACTOR(S) WILL PROTECT ALL PARTS OF THEIR WORK
FROM WEATHER DAMAGE DUE TO FROST, RAIN, HEAT, ETC. AND WILL MAKE GOOD TO
THE SATISFACTION OF THE ARCHITECT ANY PORTION OF THE WORK WHICH MAY HAVE
BECOME DAMAGED.
17.SITE SAFETY: EACH CONTRACTOR WILL ABIDE BY LOCAL AREA STANDARDS AND
RELATED O.S.H.A. STANDARDS FOR THE PROTECTION AND SAFETY FOR THEIR
EMPLOYEES ON SITE. THIS ARCHITECT WILL BE HELD HARMLESS BY BETTER BUZZ AND
GENERAL CONTRACTOR AND RELATED AWARDED TRADES ON THIS PROJECT FOR
ACCIDENTS OR INJURIES CAUSED OR ACCRUED ON THIS PROPERTY DURING THE
PRE / ACTUAL / POST CONSTRUCTION PHASES OF THIS PROJECT.
18.CONTRACTORS WILL BE RESPONSIBLE FOR REMOVAL AND ACCOUNT FOR QUANTITY
OF DEBRIS ACCUMULATED BY EACH TRADE. HOWEVER, EACH TRADE WILL KEEP THE
JOB SITE CLEAN AND SAFE AT ALL TIMES, ALONG w/ A BROOM / VACUUM FINISH AT THE
END OF EACH WORKING DAY.
19.TRANSITION OF DIFFERENT FLOORING MATERIALS AT DOORWAYS SHALL SHALL BE
FLUSH AND OCCUR AT CENTERLINE OF DOORS TYPICALLY.
20.PAINT ALL WALL SURFACES, DOOR FRAMES, WINDOW FRAMES, BULKHEADS AND
CEILINGS IN ROOMS WHERE INDICATED ON ROOM FINISH SCHEDULE. PAINT BEHIND
ALL MOVEABLE ITEMS ADJACENT TO WALLS RECEIVING PAINT AND RELOCATE ITEMS.
ALL NEW PAINTING SHALL INCLUDE (1) ONE COAT PRIMER AND (2) TWO COATS OF
PAINT (UNLESS NOTED OTHERWISE).
21.ALL WEATHER - EXPOSED SURFACES SHALL HAVE A WEATHER RESISTIVE BARRIER TO
PROTECT THE INTERIOR WALL COVERING AND EXTERIOR OPENINGS SHALL BE
FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF.
GENERAL NOTESABBREVIATIONS
AX.0
X
101
SYMBOL AND LEGEND
ELEVATION IDENTIFICATION
GRID LINE IDENTIFICATION
AX.0
X
ELEVATION DESIGNATION
1.0
A
N
SHEET REFERENCE NO.
PARTIAL SECTION IDENTIFICATION
SECTION DESIGNATION
SHEET REFERENCE NO.
AX.0
X
SECTION DETAIL IDENTIFICATION
DETAIL DESIGNATION
SHEET REFERENCE NO.
AX.0
X
ENLARGED DETAIL IDENTIFICATION
DETAIL DESIGNATION
SHEET REFERENCE NO.
INTERIOR ELEVATION IDENTIFICATION
ELEVATION DESIGNATION
SHEET REFERENCE NO.
F.O.M.
F.
O
.
S
.
GRID LINE
FACE OF STUD
FACE OF MASONRY
CENTER LINE OF COLUMN
ELEVATION REFERENCE IDENTIFICATION
TYP
12
SECTION /
ELEVATION /
FLOOR DATUM
AREA/ ROOM IDENTIFICATION
TILE SPECIFICATION
HEIGHT REFERENCE
ROOM NAME
PROJECT REFERENCE
N N NORTH ARROW
PROJECT SYMBOL IDENTIFICATION
DOOR NUMBER
MATERIAL NAME / FINISH NAME
WALL TYPE
FIXTURE / EQUIPMENT TYPE
WINDOW NUMBER
PROJECT ANNOTATION IDENTIFICATION
REVISION / ADDENDUM NUMBER
KEYNOTE NUMBER
0'-0"
FINISH FLOOR
2 B
101
F-1
GRAPHIC NAME
P-2
FDXSCXX-1
16
-
A
B
C
D
DETAIL DESIGNATION
DINING
101
9'-4"
GRID-1
ACOU-1
ROOM NUMBER
GRID SPECIFICATION
S H E E T N U M B E R
A2641
Pl
o
t
t
e
d
:
10
/
2
/
2
0
2
5
1
1
:
0
2
P
M
(
la
u
r
e
)
F
i
l
e
:
01
_
a
2
6
4
1
_
t
1
.
1
_
t
i
t
l
e
s
h
e
e
t
.
d
w
g
PROJECT NUMBER
2025.10.03
DATE
R E V I S I O N S
S T A M P
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
P
R
O
J
E
C
T
L
O
C
A
T
I
O
N
C O N S U L T A N T
S
H
E
E
T
T
I
T
L
E
C COPYRIGHT 2025 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.
16
0
1
N
B
R
I
S
T
O
L
S
T
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
6
Kevin MacDonald
801 University Avenue
San Diego, CA 92103
kevin.macdonald@betterbuzzcoffee.com
9431 HAVEN AVENUE, SUITE 212
RANCHO CUCAMONGA, CA 91730
P. 909.259.9971 | F. 909.944.8409
www.AmorArch.com
WEST COAST | CENTRAL | EAST COAST
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
TE
STA RN
FOAOCFLI
AI
LICENSED ARCHITECTWILLIAA.AMOR
DATE
8/31/2027
M
C - 24421
RENEWAL
DATE SIGNED: 10/03/2025
1 1/24/25 PLAN CHECK CORRECTIONS
2 4/1/25 PLAN CHECK CORRECTIONS
3 5/2/25 PLAN CHECK CORRECTIONS
4 10/3/25 CHANGE BULLETIN
REVISIONS
T1.1 TITLE SHEET, PROJECT INFORMATION, AND GENERAL NOTES
T1.2 GENERAL CONSTRUCTION NOTES & PROJECT RESPONSIBILITIES
T1.3 ADA STANDARDS - ACCESSIBLE DESIGN PLAN
1 2 3 4 5
A4.1
INTERIOR ELEVATIONS
A5.1
ENLARGED RESTROOM PLANS & ELEVATIONS
DETAILS
A7.2
POWER DATA PLAN
AR
C
H
I
T
E
C
T
U
R
A
L
A1.1 NEW FLOOR PLAN
A2.1
REFLECTED CEILING PLAN
EQUIPMENT / FIXTURE PLANK1.1
DOOR SCHEDULE, HARDWARE NOTES & DETAILS
A8.1
INTERIOR ELEVATIONS
A6.1
A3.1
ROOF PLAN
A7.1
T2.1 LIFE SAFETY PLAN
EQ
U
I
P
M
E
N
T
EXTERIOR ELEVATIONS
FINISH SCHEDULEA2.2
A9.1
EQUIPMENT / FIXTURE SCHEDULEK2.1
EQUIPMENT / FIXTURE SCHEDULE CONTINUEDK2.2
ST
R
U
C
T
U
R
A
L
STRUCTURAL GENERAL NOTESS1.0
A5.2
A1.2
FLOOR FINISH PLAN
EXTERIOR ELEVATIONS
FOUNDATION PLAN/ NOTESS2.0
ROOFING FRAMING PLAN/ NOTESS3.0
STRUCTURAL DETAILSS4.0
STRUCTURAL DETAILSS4.1
STRUCTURAL DETAILSS4.2
STANDARD STRUCTURAL DETAILSS5.0
STANDARD STRUCTURAL DETAILSS5.1
ME
C
H
A
N
I
C
A
L
MECHANICAL GENERAL NOTES, ABBREVIATIONS & SYMBOLSM0.1
EL
E
C
T
R
I
C
A
L
ELECTRICAL GENERAL NOTESE0.1
PL
U
M
B
I
N
G
PLUMBING GENERAL NOTES, ABBREVIATIONS & SYMBOLSP0.1
PLUMBING SCHEDULES
PLUMBING SPECIFICATIONS
PLUMBING SITE PLAN
PLUMBING DOMESTIC WATER PLAN
PLUMBING WASTE & VENT PLAN
PLUMBING REVERSE OSMOSIS & FILTERED WATER PLAN
PLUMBING RISERS
ELECTRICAL SYMBOLS AND ABBREVIATIONSE0.2
ELECTRICAL SPECIFICATIONSE0.3
KITCHEN EQUIPMENT SCHEDULESE0.4
KITCHEN EQUIPMENT SCHEDULESE0.5
ELECTRICAL SITE PLANE1.1
ELECTRICAL POWER FLOOR PLANE2.1
ELECTRICAL LIGHTING PLANE2.2
ELECTRICAL POWER ROOF PLANE3.1
ELECTRICAL POWER ROOF PLANE4.1
TITLE-24 ENERGY COMPLIANCE FORMSE5.1
TITLE-24 ENERGY COMPLIANCE FORMSE5.2
MECHANICAL SCHEDULESM0.2
M0.3
M2.1
M3.1
M4.1
TITLE 24- ENERGY COMPLIANCE FORMSM5.1
M5.2
CAPTIVE AIRE DRAWINGSM6.1
M6.2
MECHANICAL SPECIFICAITONS
MECHANICAL FLOOR PLAN
MECHANICAL ROOF PLAN
MECHANICAL DETAILS
TITLE 24- ENERGY COMPLIANCE FORMS
CAPTIVE AIRE DRAWINGS
DESCRIPTIVE SUMMARY OF WORK
THE WORK INCLUDES ALL LABOR, MATERIALS, AND EQUIPMENT TO BUILD, FINISH, AND
PROVIDE NEW COMMERCIAL BUILDING AND TENANT IMPROVEMENT FOR PROPOSED
RESTAURANT.
THE WORK SHALL INCLUDE ALL ITEMS REQUIRED AS SHOWN ON THE DRAWINGS.
ALL MECHANICAL EQUIPMENT / SYSTEMS, ALL ELECTRICAL SYSTEMS, AND EQUIPMENT
ARE TO BE INCLUDED FOR A COMPLETE OPERATING SYSTEM WITH COORDINATION AND
INSTALLATION INCLUDED.
EXTERIOR:
NEW TRASH ENCLOSURE
NEW PATIO IMPROVEMENTS
INTERIOR:
NEW INTERIOR PARTITIONS AND DOORS
NEW FLOOR, WALL AND CEILING FINISHES, PAINT/ GRAPHIC SIGNAGE.
NEW LIGHTING FIXTURES/ OUTLETS AND SWITCHES.
NEW MECHANICAL DUCTWORK, KITCHEN HOOD AND EXHAUST SYSTEMS
NEW PLUMBING FIXTURES AND KITCHEN EQUIPMENT
P0.2
P0.3
P1.1
P2.1
P2.2
P2.3
P2.4
PLUMBING ROOF PLANP3.1
PLUMBING DETAILSP4.1
PLUMBING DETAILSP4.2
TITLE-24 ENERGY COMPLIANCE FORMSP5.1
A5.3 WALL DETAILS
AS1.1 SITE PLAN
SITE DETAILS
SITE DETAILS
AS2.1
AS2.2
A5.4 EXTERIOR DETAILS
T1.4 2022 CAL-GREEN NON-RESIDENTIAL MEASURES
T1.5 2022 CAL-GREEN NON-RESIDENTIAL MEASURES
PER 2022 CA PLUMBING CODE, TABLE 422.1 MINIMUM PLUMBING FACILITIES,
(OCCUPANT LOAD OF 49 OCCUPANTS. 20 MALE AND 20 FEMALE)
WATER CLOSETS
(FIXTURES PER PERSON)
URINALS
(FIXTURES PER PERSON)
LAVATORIES
(FIXTURES PER PERSON)
MALE
1: 1-50
MALE
1: 1-100
FEMALE
2: 16-30
MALE
1: 1-75
FEMALE
1: 1-50
REQUIREMENT:
MALE
1
MALE
1
FEMALE
1
MALE
1
FEMALE
1
B OCC.
PER CALIFORNIA PLUMBING CODE 2022, 422.2 SEPARATE FACILITIES
EXCEPTION: #3 - IN BUSINESS AND MERCANTILE OCCUPANCIES WITH A TOTAL OCCUPANT LOAD
OF 50 OR LESS INCLUDING CUSTOMERS AND EMPLOYEES, ONE TOILET FACILITY, DESIGNED FOR
USE BY NO MORE THAN ONE PERSON AT A TIME, SHALL BE PERMITTED FOR USE BY BOTH SEXES.
PROVIDED:
ALL GENDER
1
ALL GENDER
1 -
MINIMUM NUMBER OF REQUIRED
PLUMBING FIXTURES
T1.6 2022 CAL-GREEN NON-RESIDENTIAL MEASURES
CEILING DETAILSA3.2
PLUMBING EQUIPMENT PLANP2.5
P2.6 PLUMBING EQUIPMENT SCHEDULE
PLUMBING SCHEDULESP0.4
BUILDING SECURITY REGULATIONS:
FOR NEW BUILDINGS AND ADDITIONS, ALTERATIONS, AND REPAIRS WITHIN ANY
TWELVE-MONTH PERIOD EXCEED FIFTY (50%) PERCENT OF THE VALUE OF ANY EXISTING
BUILDING OR STRUCTURE, EACH BUILDING OR STRUCTURE SHALL BE MADE TO
CONFORM TO THE REQUIREMENTS FOR NEW BUILDINGS OR STRUCTURES AND COMPLY
WITH THE BUILDING SECURITY REGULATIONS. SANTA ANA MUNICIPAL CODE CHAPTER 8,
DIVISION 3.
DETAILSA8.2
4
BA
K
E
R
Y
CA
S
E
28
"
X
2
5
"
1
2
3.2
5
6
E D C B AF
1
2
4
5
6
3
ENTRY
EN
T
R
Y
30x48
30
x
4
8
18
x
4
8
5-
t
i
e
r
18
x
4
2
18x60
5-tier
18
x
4
8
5-
t
i
e
r
18
x
4
2
18x60
5-tier
18x60
5-tier
18
x
3
6
5-
t
i
e
r
18x60
5-tier
18x60
5-tier
18x60
5-tier
18x60
5-tier
18x60
5-tier
18
x
3
6
5-
t
i
e
r
BAKERY CASE
30x48
A5.2
8
6
A5.2
6
A5.1
8
A5.1
DRIVE THRU
107
10'-0"
DINING
101
14'-2"
14'-2"
100
14'-2"
PRODUCTION BAR
106
10'-0"
SERVICE
105
10'-0"SALES
102
10'-0"
COOKLINE
108
10'-0"
PREP
111
10'-0"
WALK-IN FREEZER
110
-
MECH RM
113
ELEC RM
112
10'-0"
DRY STORAGE
109
10'-0"
UNISEX RESTROOM
104
9'-0"HALLWAY
103
10'-0"
101
102
103
107
104
105
56'-7"
11'-4"20'-0"16'-8"8'-7"
38
'
-
0
"
30
'
-
6
"
7'
-
6
"
57'-1"
2'-6"3'-4"9'-7"15'-0"8'-7"
7'
-
0
"
16
'
-
0
"
7'
-
0
"
30
'
-
6
"
6"
4'
-
0
"
21
'
-
9
"
3'
-
0
"
2'
-
0
"
3'-6"
3'-0"
1
TYP.
2
3
4
5
6
7 8
159
9
10
13
14
14
16
17
17
17
18
19
20
3'
-
0
"
4'
-
0
"
6'-5"9'-8"
12
17
8
A7.1
A
D
C
B
8
A7.1
E
12
A6.1
2
A8.1
8
A7.1
F
G
8
A7.2
C
E
D
8
A7.2
J
G
C
H
8
A7.2 I
8
A7.2 BA
106
A5.3
4
A5.3
16
A5.3
12
3'
-
1
"
7'
-
8
"
9"
3'
-
0
"
13
'
-
0
"
3'
-
0
"
2'-0"
6'-6"
1'-9"
A
B
D
E
F
2'-6"6'-5"2'-6"
4'-0"
C
21
21
21
222
A8.2
3'
-
9
"
4'-2"
3'-7"
3'
-
7
"
4'-6"
3'-7"
3'-8"
3'
-
5
"
4'-7"
3'-4"
3'
-
3
"
3'-1"
3'-11"
4'
-
2
"
3'
-
6
"
3'-9"
AS2.1
8
AS2.1
8
AS2.1
8
1'
-
0
"
5'
-
2
"
13
'
-
2
"
3'
-
5
"
5'-3"5'-5"8'-11"
3'
-
5
"
7'
-
1
"
11'-9"
1'
-
6
"
7"
11
"
7'
-
1
0
"
5'
-
1
"
12
'
-
3
"
3'-4"4'-2"2'-7"
3'-9"
5"4'
-
5
"
2'
-
7
"
5'
-
4
"
2'
-
6
"
2'
-
6
"
2'
-
1
0
"
EQ EQ
10'-3"5'-10"
1'-4"3'-6"
9'
-
8
"
7'
-
9
"
4'
-
6
"
3'
-
1
1
"
3'
-
3
"
15'-7"
1'
-
6
"
7'-9"
21'-6"8'-1"
6'
-
1
"
17
'
-
7
"
9'
-
0
"
5'-4"
1'-7"
8'
-
0
"
1'
-
1
"
5'
-
1
0
"
9'-9"
4'-11"4'-11"
12
'
-
5
"
5'
-
2
"
9'-2"
7'-8"
7'
-
3
"
4'-1"
8"
10'-11"
4'
-
1
1
"
1'-2"
(N
)
F
L
O
O
R
P
L
A
N
A1.1(N) FLOOR PLAN
1/4" = 1'-0"
KEYNOTES
1
2 INSTALL 4'-0" W X 10'-0" H X 18 GA STAINLESS STEEL PANEL BEHIND OVENS. REFER TO
INTERIOR KITCHEN ELEVATIONS AND EQUIPMENT PLAN FOR EXACT LOCATION AND SIZE.
GC SHALL VERIFY THAT THE PANELS WILL EXTEND 18" AROUND ALL HEAT PRODUCING
EQUIPMENT TO CONFORM TO MANUFACTURER SPECIFICATIONS.
ALL GYPSUM BOARD BELOW FINISHED CEILING HEIGHT IS TO BE PREPARED FOR
PAINTING (LEVEL 5 FINISH) OR WALL COVERING AS INDICATED ON INTERIOR ELEVATIONS
AND FINISH SCHEDULE. SEE GENERAL CONSTRUCTION NOTES FOR DINING AREA
GENERAL CONTRACTOR (G.C.) TO PROVIDE 2"X2"XFULL HEIGHT HIGH CORNER GUARDS
ON ALL OUTSIDE CORNERS @ KITCHEN WALL, PROVIDE COMPLETE WRAP ON END
WALLS.
HOOD WALL TO BE CONSTRUCTED WITH 6" X20 GAUGE METAL STUDS AT 24" O.C. AND (2)
LAYERS OF 5/8" FIRE RATED GYPSUM ON BOTH SIDES OF WALL
G.C. TO INSTALL 18 GA. STAINLESS STEEL PANELS ON WALL. REFER TO EQUIPMENT
SCHEDULE FOR SIZES AND INTERIOR ELEVATIONS FOR LOCATIONS
(E) DOOR & FRAME TO REMAIN. ALL DOORS SHALL BE ABLE TO BE OPENED FROM THE
EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT.
MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS SHALL NOT BE USED.
PAINTED TO BE ORANGE
PROVISIONS FOR EXIT DISCHARGE LIGHTING ARE SHOWN ON THE LIGHTING PLAN.
PROVIDE STAINLESS STEEL FLASHING AT WALK-IN FREEZER AND COOLER CORNERS.
PORTABLE FIRE EXTINGUISHER PER NFPA-10 AND INSTALLED BY GC ON SITE AND
SUBJECT TO LOCAL JURISDICTION APPROVAL.
PROVIDE 1/2" PLYWOOD SHEATHING AT ALL SHELVES AS DIMENSIONED ON INTERIOR
ELEVATIONS.
SOLID SURFACE SPLASH GUARD TO MATCH COUNTERTOP.
SOFFIT ABOVE COUNTER STAINED TO MATCH COUNTER (SERVES AS BOUNDARY FOR
CEILING CHANGE BETWEEN KITCHEN AND DINING).
3
4
5
6
7
8
9
10
11
12
13
8SCALE
1/4" = 1'-0"
N
(N) ALUMINUM STOREFRONT SYSTEM W/ FIXED, LOW-E INSULATED GLAZING14
(N) AIR CURTAIN DOOR SWITCH ACTIVATED15
(N) AUTOMATIC DRIVE THRU WINDOW16
17 LINE OF (N) METAL CANOPY ABOVE
DETAIL NUMBER
SHEET NUMBER
SHEET NUMBER
DETAIL NUMBER
XXX
DOOR NUMBER. SEE SHEET A9.1 FOR DETAILS
ARROW INDICATES DIRECTION OF VIEW
FRAMING SCHEDULE
101
DENOTES BLOCKING AS REQUIRED
EXISTING FRAMING
FURRED WALL INFILL. 2X GYP. BD. ON BOTH SIDES
A WINDOW TAG. SEE SHEET A9.1 FOR DETAILS
2X4 METAL FRAMING @ 16" O.C.
2X6 METAL FRAMING @ 16" O.C.
2X8 METAL FRAMING @ 16" O.C.
2X6 METAL FRAMING @ 16" O.C. w/ (2) LAYERS 5/8" TYPE 'X' GYP. BD.
SPECIFICATION
DIVISION 9: FINISHES SECTION 9A: GYPSUM WALLBOARD
GENERAL PROVISIONS
SCOPE: FURNISH AND INSTALL GYPSUM WALLBOARD AS A SUBSTRATE FOR OTHER
FINISH MATERIALS ON ALL INTERIOR WALLS (AND THE INTERIOR PORTIONS OF
EXTERIOR WALLS WHERE REQUIRED). FURNISH AND INSTALL GYPSUM BOARD
SUSPENDED CEILING WITH HANGERS AND SUPPORTS AS RECOMMENDED BY
MANUFACTURER.
1.MATERIALS
MATERIAL NAMES ARE BASED ON A NATIONAL GYPSUM GOLD BOND STA-SMOOTH BEVEL
EDGE SYSTEM. USE GOLD BOND OR EQUAL SYSTEM BY U.S. GYPSUM.
WALLS (EXCEPT WHERE NOTED): 1/2" STA-SMOOTH GYPSUM WALLBOARD
WALLS WHERE NOTED: 1/2" THICK TAPERED EDGE M/R (MOISTURE
RESISTANT) GYPSUM WALLBOARD
DROPPED CEILING WHERE NOTED:1/2" STA-SMOOTH GYPSUM WALLBOARD
FIRE RATED WHERE NOTED OR 5/8" FIRE SHIELD (GYPSUM WALLBOARD)
REQUIRED BY CODE
2.FASTENERS:
A.GWB-54 1-5/8" LONG ANNULAR RING SHANK NAILS MEETING THE REQUIREMENTS OF
ASTM C-380.
B.1-1/4" LONG TYPE-W DRYWALL SCREWS TO WOOD STUDS.
C.1-1/4" LONG TYPE-S DRYWALL SCREWS TO INTERIOR METAL STUDS.
D.1-1/4" LONG TYPE-S12 CORROSION RESISTANT SCREWS FOR EXTERIOR GYPSUM
SHEATHING TO METAL STUDS.
E.JOINT TREATMENT COMPOUND SHALL BE READY MIXED. JOINT TAPE SHALL BE CROSS
FIBERED, PERFORATED, FEATHER EDGED. CORNER BEADS SHALL BE GALVANIZED
STEEL ROLL-FORMED U-SHAPED CHANNELS.
F.HANGERS AND SUPPORTS: 2X4 WOOD FRAMING. SUBSTITUTION: FOR STEEL TRUSS
BUILDINGS 1-1/2" CARRYING CHANNELS, 3/4" FURRING CHANNELS, 8 GAGE HANGER
WIRES, 16 GAGE TIE WIRES, AND 1" TYPE S SCREWS.
PERFORMANCE
1. INSTALLATION
A.CUTTING WALLBOARD: GYPSUM WALLBOARD SHALL BE CUT BY SCORING AND BREAKING,
OR BY SAWING, WORKING FROM THE FACE SIDE. WHERE BOARD MEETS PROJECTING
SURFACES, IT SHALL BE SCRIBED NEATLY.
B.INSTALLING WALLBOARD: GYPSUM WALLBOARD SHALL BE APPLIED AT RIGHT ANGLES TO
FRAMING MEMBERS. BOARDS OF MAXIMUM PRACTICAL LENGTH SHALL BE USED SO
THAT AN ABSOLUTE MINIMUM NUMBER OF END JOINTS OCCUR. WALLBOARD JOINTS AT
OPENINGS SHALL BE LOCATED SO THAT NO END JOINT SHALL ALIGN WITH EDGES OF
OPENINGS. END JOINTS SHALL BE STAGGERED.
C.FASTENING WALLBOARD: ATTACH WITH SCREWS OR NAILS SPACED APPROXIMATELY 8"
O.C.. THE NAILS SHALL BE DRIVEN HOME WITH THE HEAD SLIGHTLY BELOW THE SURFACE
OF THE BOARD IN A DIMPLE FORMED BY THE DRIVING TOOL.
D.FASTENING EXTERIOR GYPSUM SHEATHING: ATTACH TO METAL STUDS (OPTIONAL) WITH
SCREWS @ 12" O.C. WITH HEAD FLUSH WITH SURFACE.
E.JOINTS FINISHING: JOINT COMPOUND, QUICK-TREAT, AND TOPPING COMPOUND SHALL
BE APPLIED IN ACCORDANCE WITH PRINTED INSTRUCTIONS CONTAINED IN THE
PACKAGE. A UNIFORMLY THIN LAYER OF JOINT COMPOUND SHALL BE APPLIED OVER THE
JOINT UNDER THE TAPE TO PROVIDE PROPER BOND. CEILING AND WALL ANGLES AND
INSIDE CORNER ANGLES SHALL BE REINFORCED WITH THE TAPE FOLDED TO CONFORM
TO THE ANGLE AND EMBEDDED IN THE COMPOUND.
AFTER THE COMPOUND IS THOROUGHLY DRY, APPROXIMATELY TWENTY FOUR (24)
HOURS FOR REGULAR COMPOUND, 2-1/2 HOURS FOR QUICK TREAT, THE TAPE SHALL BE
COVERED WITH A COAT OF JOINT COMPOUND OR TOPPING COMPOUND SPREAD OVER
THE TAPE APPROXIMATELY 3" ON EACH SIDE OF TAPE, AND FEATHERED OUT AT THE
EDGE. AFTER THOROUGHLY DRY, APPLY ANOTHER CROWN OVER JOINTS. THIS COAT
SHALL BE SMOOTH AND THE EDGES FEATHERED APPROXIMATELY 3" BEYOND THE
PRECEDING COAT. ALLOW EACH APPLICATION OF COMPOUND TO JOINTS AND NAIL
HEADS TO DRY, THEN SAND IF NECESSARY. ALL WALLBOARD AND TREATED AREAS
SHALL BE SMOOTH (LEVEL 5) AND READY FOR PAINTING.
KITCHEN WALL NOTES:
1.ALL KITCHEN WALLS SHALL RECEIVE 1/2" USG DUROCK INSTALLED UP TO 18" AFF, AND
1/2" MOISTURE RESISTANT PLYWOOD OR 5/8" DUROCK WALL BOARD OR 1/2" GYPSUM
BOARD. REFER TO THE FLOOR PLAN FOR APPLICATIONS. PLYWOOD IS NEEDED FOR
SHELVING, 5/8" DUROCK IS NEEDED AT ALL HEAT PRODUCING EQUIPMENT AND 1/2"
GYPSUM BOARD AT ALL OTHER LOCATIONS.
RESTROOM WALL NOTES:
1.ALL RESTROOM WALLS SHALL RECEIVE 1/2" USG DUROCK INSTALLED UP TO 18" AFF,
AND 1/2" MOISTURE RESISTANT GYPSUM BOARD FROM 18" TO UNDERSIDE OF TRUSSES.
BLOCKING SHALL BE PROVIDED WHERE TOILET ROOM ACCESSORIES ARE BEING
INSTALLED.
DINING AREA NOTES:
1.MARLITE TO ADHERE TO 1/2" PLYWOOD SUBSTRATE. PLYWOOD FROM FINISH FLOOR TO
2'-10" AFF.
2.MARLITE COVERING ON 1/2" GYPSUM BOARD.
3.INSTALL 1/2" GYPSUM WALL BOARD FROM 2'-10" TO UNDERSIDE OF TRUSSES.
BLOCKING NOTES:
1."xxxxxxx" INDICATES BLOCKING REQUIRED IN WALL FOR PLUMBING LINES AND
RESTROOM ACCESSORIES. BLOCKING SHALL BE FIRE RETARDANT WHERE REQUIRED BY
CODE.
2.CONTRACTOR TO VERIFY REQUIREMENTS WITH LOCAL BUILDING OFFICIALS PRIOR TO
BIDDING. CONTRACTOR IS RESPONSIBLE FOR OBTAINING MANUFACTURERS CUT
SHEETS AND LOCATING BLOCKING AS REQUIRED. THIS INCLUDES KITCHEN EQUIPMENT
AND ITEMS FURNISHED AND INSTALLED BY OTHERS.
FRAMING NOTES:
1.CONTRACTOR MAY SUBSTITUTE METAL STUDS FOR INTERIOR WALL, AND SOFFIT
FRAMING. WHERE USED, METAL FRAMING TO BE 25 GA. UNLESS NOTED OTHERWISE
(U.N.O.).
GENERAL CONSTRUCTION NOTES
2.REFER TO FRAMING NOTES FOR WALL SECTIONS.
3.ALL INTERIOR WOOD FRAMING TO BE #2 SPRUCE, FIR OR WHITE PINE OR OF EQUAL
GRADE. WHERE REQUIRED BY CODE, FRAMING SHALL BE #2 FIRE RETARDANT
YELLOW PINE. CONTRACTOR TO VERIFY REQUIREMENTS WITH LOCAL BUILDING
OFFICIALS PRIOR TO BIDDING.
4.ALL WOOD IN CONTACT WITH THE SLAB MUST BE PRESSURE TREATED.
5.ALL INTERIOR WALLS TO BE FRAMED TO UNDERSIDE OF TRUSS U.N.O..
6.ALL INTERIOR WALLS THAT ARE NOT SHEAR WALLS TO BE ANCHORED W/ 5/8" DIA.
EXPANSION ANCHORS AT 6'-0" O.C. SEE STRUCTURAL DWGS. FOR SHEAR WALL
ANCHORS.
GENERAL NOTES:
1.HANDICAP ACCESS TO BUILDING IS DESIGNED ACCORDING TO APPLICABLE CODE.
G.C. TO ENSURE THAT ALL DIRECTIONS AND DIMENSIONS GIVEN ARE STRICTLY
ADHERED TO. IF CHANGES ARE MADE THAT CONTRADICT WITH THE DRAWING, OR IF
EXISTING FIELD CONDITIONS MAKE THE DRAWINGS NOT APPLICABLE, THE ARCHITECT
MUST BE CONTACTED IMMEDIATELY.
2.ALL GLAZING WITHIN A 24" ARC OF DOORS WHOSE BOTTOM IS LESS THAN 60" ABOVE
THE FLOOR AND ALL GLAZING IN DOORS IS SAFETY, TEMPERED.
DIMENSIONS ARE SHOWN:
1.EXTERIOR WALLS: FROM INTERIOR FACE OF GYPSUM BOARD TO THE EXTERIOR FACE
OF PLYWOOD.
2.INTERIOR WALLS: FROM THE FACE OF FINISH WALL TO THE FACE OF FINISH WALL,
U.N.O..
18
19
20 PASS THROUGH OPENING AT WALL
S H E E T N U M B E R
A2641
Pl
o
t
t
e
d
:
10
/
3
/
2
0
2
5
8
:
5
0
A
M
(
la
u
r
e
)
F
i
l
e
:
09
_
a
2
6
4
1
_
a
1
.
1
_
f
l
o
o
r
p
l
a
n
.
d
w
g
PROJECT NUMBER
2025.10.03
DATE
R E V I S I O N S
S T A M P
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
P
R
O
J
E
C
T
L
O
C
A
T
I
O
N
C O N S U L T A N T
S
H
E
E
T
T
I
T
L
E
C COPYRIGHT 2025 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.
16
0
1
N
B
R
I
S
T
O
L
S
T
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
6
Kevin MacDonald
801 University Avenue
San Diego, CA 92103
kevin.macdonald@betterbuzzcoffee.com
9431 HAVEN AVENUE, SUITE 212
RANCHO CUCAMONGA, CA 91730
P. 909.259.9971 | F. 909.944.8409
www.AmorArch.com
WEST COAST | CENTRAL | EAST COAST
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
TE
STA RN
FOAOCFLI
AI
LICENSED ARCHITECTWILLIAA.AMOR
DATE
8/31/2027
M
C - 24421
RENEWAL
DATE SIGNED: 10/03/2025
1 1/24/25 PLAN CHECK CORRECTIONS
2 4/1/25 PLAN CHECK CORRECTIONS
3 5/2/25 PLAN CHECK CORRECTIONS
4 10/3/25 CHANGE BULLETIN
ELECTRICAL PANELS / EQUIPMENT
WALL LEGEND
(N) EXTERIOR WALL
(N) INTERIOR WALL. SEE FRAMING SCHEDULE.
(N) COOLER WALL
(N) TACTILE EXIT SIGN
(N) INTERNATIONAL ACCESSIBILITY SYMBOL
T1.3
2
T1.3
4
21 FURNITURE SHOWN IN DASHED LINES PROVIDED BY OWNER. GC TO INSTALL.
22 BUILT-IN COMMUNITY TABLE. SEE DETAIL A8.2
2
A8.2
3
A8.2
4
4
4
4 4
CE
I
L
I
N
G
D
E
T
A
I
L
S
A3.2
S H E E T N U M B E R
A2641
Pl
o
t
t
e
d
:
10
/
2
/
2
0
2
5
1
1
:
0
2
P
M
(
la
u
r
e
)
F
i
l
e
:
13
_
a
2
6
4
1
_
a
3
.
2
_
r
c
p
d
e
t
a
i
l
s
.
d
w
g
PROJECT NUMBER
2025.10.03
DATE
R E V I S I O N S
S T A M P
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
P
R
O
J
E
C
T
L
O
C
A
T
I
O
N
C O N S U L T A N T
S
H
E
E
T
T
I
T
L
E
C COPYRIGHT 2025 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.
16
0
1
N
B
R
I
S
T
O
L
S
T
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
6
Kevin MacDonald
801 University Avenue
San Diego, CA 92103
kevin.macdonald@betterbuzzcoffee.com
9431 HAVEN AVENUE, SUITE 212
RANCHO CUCAMONGA, CA 91730
P. 909.259.9971 | F. 909.944.8409
www.AmorArch.com
WEST COAST | CENTRAL | EAST COAST
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
TE
STA RN
FOAOCFLI
AI
LICENSED ARCHITECTWILLIAA.AMOR
DATE
8/31/2027
M
C - 24421
RENEWAL
DATE SIGNED: 10/03/2025
1 1/24/25 PLAN CHECK CORRECTIONS
2 4/1/25 PLAN CHECK CORRECTIONS
3 5/2/25 PLAN CHECK CORRECTIONS
4 10/3/25 CHANGE BULLETIN
HEAVY DUTY
MAIN TEE
MAX., T
Y
P
.
45°
TYP.
CROSS TEE6'' MAX.
#6 STSM
SCREW
VERTICAL STRUT 12'-0" O.C.,
6'-0" MAX. FROM WALL.
ATTACH TO ROOF DECK
ABOVE.
SPLAY-WIRE VERTICAL BRACING PERPENDICULAR TO
RUNNER. HANGERS TO BE 12 GALVANIZED, SOFT -
ANNEALED MILD STEEL WIRE AT 12'-0'' O.C. AND 6'-0" MAX.
FROM END WALLS. ATTACHED WITH MINIMUM OF (3)
TURNS TO CEILING SUSPENSION MEMBERS AND TO 14" x 2.5''
EYE LAG SCREW INTO BOTTOM EDGE OF ROOF JOIST.
PROVIDE COUNTER SLOPING WIRES WHERE WIRES ARE
SPLAYED MORE THAN 1 IN 6 OUT OF PLUMB.
2''
NOTE:
GROUP OF (4) 45° WIRES
AND VERTICAL STRUT
OCCUR AT THE SAME
INTERSECTIONS.
#12 GA. SPLAY-WIRE
LATERAL BRACING IN
PLANE OF EACH RUNNER,
AND TIED w/ (4) TIGHT
TURNS, TYP.
CEILING BRACING DETAIL 3" = 1'-0"
SCALE
ACOUSTICAL CEILING SUSPENSION SYSTEM, ICC-ES REPORT: ESR-1222
NOTE:
EYE LAG SCREW TO HAVE
MIN. 1-1/4" PENETRATION
SPREADER
FASTENED TO WALL
WALL STRUCTURE
(SEE FLOOR PLAN FOR TYPE)
HEAVY DUTY
T-BAR SYSTEM
NOTE:
1.PROVIDE SPREADER BAR IF CROSS TEE OR MAIN TEE DISTANCE TO
WALL IS GREATER THAN 8''.
2.TWO ADJACENT CEILING GRID EDGES MUST BE ATTACHED TO THE
PERIMETER ANGLE, AND THE OTHER TWO EDGES MUST BE FREE TO
SLIDE AND HAVE 3/4'' MINIMUM CLEARANCE FROM WALL.
3/4" MIN.
8" (MAX.)
CEILING PERIMETER 3" = 1'-0"
SCALE
2" MIN.
ACOUSTICAL CEILING
SUSPENSION SYSTEM
ICC-ES REPORT: ESR-1222
TYP. T-BAR GRID 3" = 1'-0"
SCALE
S
(TYP.)
45° MAX.
W
(TYP.)
45° MAX.
N
E
12 GA. VERTICAL HANGER
WIRES @ 4'-0" OC EA. WAY,
TYP., w/ MIN. 3 TIGHT
TURNS IN 1 1/2" AT BOTH
ENDS OF WIRE
SET OF FOUR 12 GA.
BRACING WIRES AT 12'-0"
OC EA. WAY, TYP., w/MIN. 4
TIGHT TURNS IN 1 1/2" AT
BOTH ENDS OF WIRE
COMPRESSION STRUTS LOCATED WITH
SETS OF BRACING WIRES AT 12'-0" OC
EA. WAY - STEEL SECTION WITH L/R
RATIO OF 200 MAXIMUM. ATTACH TO
MAIN RUNNERS WITH 1/4 INCH Ø
MACHINE BOLTS AND TO SLAB ABOVE
WITH 0.177"Ø POWDER-DRIVEN FAS-
TENERS. COMPRESSION STRUT SHALL
NOT REPLACE HANGER WIRE. 6' MAX.
TO THE WALL
NOTE:
FOR CONNECTIONS OF
BRACING AND HANGER
WIRES TO THE
STRUCTURE ABOVE, SEE
CEILING NOTES.
2" (MAX.) FROM
BRACING WIRES TO
CROSS RUNNERS
GRID SYSTEM
MAIN RUNNER
CROSS RUNNER
SOFFIT DETAIL 1 1/2" = 1'-0"
SCALE
(E) ROOF DECK
(V.I.F.)
(E) TRUSSES
CONT. METAL
TOP TRACK,
TYP.
PAINTED MTL.
CORNER BEAD, TYP.
CONT. METAL TRACK
(E) TRUSSES
5/8" GYPSUM BOARD
PAINTED PER
ELEVATION
3 5/8" x 20 GA.
METAL STUDS
@16" O.C, TYP.
5/8" GYPSUM BOARD
PAINTED PER
FINISH SCHEDULE
3 5/8" x 20 GA.
METAL STUDS
@16" O.C, TYP.
METAL STUDS
@16" O.C, TYP.
2
3
4
7
FIXTURE CONNECTION 1 1/2" = 1'-0"
SCALE
(E) 2x4 JOISTS OR
(N) BLOCKING @ 24" O.C.(E) ROOF SHEATHING
WIRING RUN WITHIN UNISTRUT
CLOSURE STRIP
POWER CABLE FROM LIGHT FIXTURE,
CLIPPED TO DOWN ROD
(BY LIGHT FIXTURE MANUFACTURER)
ATTACH P1000KO 1-5/8"
UNISTRUT PRIMARY RAIL
FACE DOWN TO (E) JOIST
PER INDUSTRY STANDARDS
J-BOX AS REQUIRED
BY FIXTURE
MANUFACTURER
WHERE OCCURS, ATTACH UNISTRUT PERPENDICULARLY OVER
(2) JOISTS MINIMUM (TYPICAL)
CEILING HT. SEE RCP
6"
UNISTRUT SECONDARY RAIL
CONNECT TO BEAM
ROD AND HANGER
1
5/8" GYPSUM BOARD
7/8" HAT CHANNELS
NOTE:
ARMSTRONG GYPSUM BOARD
SUSPENSION SYSTEM, OR AN
APPROVED ALTERNATE TO STICK
BUILT DESIGN.
DIAGONAL #12 HANGER
WIRE TO CONTROL RACKING
OF CEILING SYSTEM
1 1/2" METAL STUDS
HUNG FROM TOP CHORD
OF ROOF JOISTS
#10 VERTICAL HANGER
WIRE, AT 48" O.C.
SCALE
N.T.S.SUSPENDED GYPSUM BOARD CEILING DETAIL
ICC ESR-1166P
8WIRE CONNECTION SCALE
3" = 1'-0"
AT WOOD JOIST OR RAFTER TO BOTTOM OF JOIST
TJI UPPER FLANGE TJI LOWER FLANGE
3"
1
4" DIA. SCREW EYE W/ FULL
TREAD EMBED. 1 1
4" MIN. TYP.
ALL CONNECTION
JOIST OR
RAFTER
BRACING WIRE
FOR BRACING WIRE -
FULLY EMBED. SCREW
EYE TREADS IN
DIRECTION OF WIRE
HANGER WIRE HANGER WIRE -
3 TIGHT TURNS & BRACING
WIRES - (4) TIGHT TURNS
2"
M
I
N
1
4" DIA. DRILLED
HOLE
NOTE: SOLID BLOCKING
REQUIRED FOR EITHER
TYPE OF BRACING WIRE
DO NOT INSERT SCREW
EYES INTO SIDE OF TJI
FLANGE
NOTE: DO NOT INSERT SCREW
EYES PERPENDICULAR TO
WEB IN FLANGE
TJI
BRACING WIRE
1" MIN
1
4" DIA. SCREW
EYE W/ 1 1
4" MIN.
PENETRATION
TJI
BRACING WIRE
9
4
18x48
5-tier
18x42
18
x
6
0
5-
t
i
e
r
18x48
5-tier
18x42
18
x
6
0
5-
t
i
e
r
NOTE:
DIMENSIONS SHOWN ARE ACTUAL DIMENSIONS
2"2'-10"4"
13
-
9
-
7'
-
1
"
10'-11"
KEYNOTES:
REFER TO EQUIPMENT SCHEDULE ON SHEET K2.1 -K2.2 FOR MORE INFORMATION.
4-TIER COOLER STORAGE SHELVING
WALK-IN COOLER WITH LIGHT KIT
EVAPORATOR COIL FOR WALK-IN COOLER
SCALE
1/2" = 1'-0"DETAIL 2
SELF CLOSING HINGES
2" DIAL THERMOMETER
PILOT SWITCH
84" FLUSH BOTTOM DOOR
SCALE
3/8" = 1'-0"
DOOR @ COOLER
KICK PLATE (32"X32")
NOTE:
NO DIAMOND PLATE FINISH WILL BE USED
FOR THE INTERIOR AND EXTERIOR OF
THE WALK-IN FREEZER & COOLER,
INCLUDING THE DOOR KICKPLATE
WA
L
L
P
E
R
P
L
A
N
4"
M
I
N
.
AI
R
G
A
P
WALK-IN WALL
BACKER-ROD
& SEALANT
FULL LENGTH .040 ALUM.
CLOSURE ANGLE W/ HEMMED
EDGES W/ SILICONE BEAD
CONT. EACH SIDE
SCALE
3" = 1'-0"
FLASHING @ W.I.C.
EXTERIOR WALL
SCALE
N.T.S.
NOTE:
SEE SHEET T1.1 DEFERRED SUBMITTAL
FOUNDATION DETAILS AND ADDITIONAL NOTES. TO BE PROVIDED AT TIME OF SUBMITTAL.
G.C. TO COMPLY WITH ALL W.I.B. MANUFACTURER RECOMMENDATIONS FOR
PREPARATION AND INSTALLATION OF W.I.B. SLAB.
COOLER REFRIGERATION SHALL BE SIZED TO MAINTAIN 34 DEG. F. FREEZER
REFRIGERATION SHALL BE SIZED TO MAINTAIN -10 DEG. F. WALK-IN COOLER SHALL BE
PROVIDED WITHOUT FLOOR. WALK-IN FREEZER SHALL BE PROVIDED WITH 4" INSULATED
FLOOR AND INTERIOR RAMP AT DOOR.
THE WALK-IN MANUFACTURER WILL PROVIDE:
1) THE WALK-IN COOLER & FREEZER
2) REFRIGERATION EQUIP. SIZED TO MEET BETTER BUZZ REQUIREMENTS, FACTORY
ASSEMBLED AND WITH LOW AMBIENT CONTROLS, INCLUDING ALL WIRING,
REFRIGERATION PIPING, W/ REMOTE UNITS MOUNTED ON S.S. RAILS LOCATED ON
THE ROOF, AND READY FOR FINAL CONNECTION TO ALL NECESSARY UTILITIES.
3) DELIVERY OF THE BOXES
4) CONTRACTOR TO INSTALL WALK-IN BOX AND REFRIG.
IT SHALL BE THE RESPONSIBILITY OF THE G.C. TO CONTACT WALK-IN BOX PROVIDER AND
OBTAIN A COPY OF THE SHOP DRAWINGS FOR THIS PROJECT PRIOR TO ROUGH IN OF
UTILITIES. FAILURE TO OBTAIN SHOP DRAWINGS PRIOR TO ROUGH IN WILL NOT RESULT IN
EXTRA CHARGES TO THE OWNER FOR RELOCATION OF UTILITIES.
W.I.B. NOTES
DE
T
A
I
L
S
A8.1
913
10
12
S H E E T N U M B E R
A2641
Pl
o
t
t
e
d
:
10
/
2
/
2
0
2
5
1
1
:
0
2
P
M
(
la
u
r
e
)
F
i
l
e
:
21
_
a
2
6
4
1
_
a
8
.
1
_
d
e
t
a
i
l
s
.
d
w
g
PROJECT NUMBER
2025.10.03
DATE
R E V I S I O N S
S T A M P
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
P
R
O
J
E
C
T
L
O
C
A
T
I
O
N
C O N S U L T A N T
S
H
E
E
T
T
I
T
L
E
C COPYRIGHT 2025 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.
16
0
1
N
B
R
I
S
T
O
L
S
T
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
6
Kevin MacDonald
801 University Avenue
San Diego, CA 92103
kevin.macdonald@betterbuzzcoffee.com
9431 HAVEN AVENUE, SUITE 212
RANCHO CUCAMONGA, CA 91730
P. 909.259.9971 | F. 909.944.8409
www.AmorArch.com
WEST COAST | CENTRAL | EAST COAST
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
TE
STA RN
FOAOCFLI
AI
LICENSED ARCHITECTWILLIAA.AMOR
DATE
8/31/2027
M
C - 24421
RENEWAL
DATE SIGNED: 10/03/2025
1 1/24/25 PLAN CHECK CORRECTIONS
2 4/1/25 PLAN CHECK CORRECTIONS
3 5/2/25 PLAN CHECK CORRECTIONS
4 10/3/25 CHANGE BULLETIN
SCALECOUNTER COVED BASE 3/4" = 1'-0"
TILE BASE
COUNTER/ CABINET
3/8" MIN.
(TYP.)
FLOOR TILE
3/8" RADIUS BASE COVE4"
MI
N
COUNTER BASE
SCALEWALL COVED BASE 3/4" = 1'-0"
TILE BASE
3/8" MIN.
(TYP.)
FLOOR TILE
3/8" RADIUS BASE COVE
6"
GYPSUM BOARD
(INTERIOR WALL)
SCALE
WALL MOUNT BRACKET
PANEL BRACKET
3'-7 1/2"
1'-3 3/4"1'-0"1'-3 3/4"
N.T.S.
9"
1'
-
4
"
10
"
1'
-
3
"
3"
7 1/2"
MONITOR BRACKET DETAIL (SIDE AND REAR)
3/4" = 1'-0"
SCALESELF-SERVE COUNTER ELEVATION
FINISH ENTIRE WALL INCLUDING PAINTING
PRIOR TO INSTALLATION OF MILL WORK
3/4" PLYWOOD FACING
W/ PLASTIC LAM.
WOOD PANEL FINISH
1/2" PLYWOOD CABINET FLUSH
MOUNTED DOORS W/ LAM.
WOOD PANEL FINISH W/ (3)
STAINLESS STEEL, WIRE
PULLS AND PIANO HINGES, (2)
PER DOOR
4"
8'-0" (VERIFY IN FIELD)
PROVIDE WOOD BRACE
CENTER LINE OF COUNTER SS-1 SOLID SURFACE
COUNTER-TOP, WITH
BACK-SPLASH TO MATCH
2'
-
1
0
"
M
A
X
.
48
"
M
A
X
.
TO
C
O
N
T
R
O
L
A
C
C
E
S
S
STAINLESS STEEL LEG
COVED BASE w/
3/8" RAD. BEYOND
PROTECT
SYRUP LINES
FROM TRUSS
ANGLE
BUNDLED
SYRUP LINES &
FILTERED
WATER LINE
OPTIONAL
INSTALLATION
1" WIDE GALV.
STRAPS @ EA.
TRUSS (MIN.6'-0")
BOTTOM CHORD
OF ROOF TRUSS
NOTE:
SYRUP LINE BUNDLE (OWNER
FURNISHED, AND INSTALLED)
6" = 1'-0"
SCALESYRUP LINESSCALEWALL & FLOOR JOINT @
RESTROOM 3" = 1'-0"
SCHLUTER DILEX AHK ACGB
(BRUSHED CHROME) OR EQUAL
IN 3/8" MIN. RADIUS COVING
TILES, SEE FINISH SCHEDULE
1/8" SANDED OR EPOXY GROUT
ON WALL AND FLOOR. SEE FINISH
SCHEDULE
BONDED WATERPROOFING
MEMBRANE
CEMENTITIOUS
BOND COAT
2'
-
0
"
M
I
N
.
3
48
15
1417
16
12
16
18 TYP. INTERIOR WALL 1 1/2" = 1'-0"
SCALE
SEE RCP
CEILING HT.
SUSPENDED T-BAR CEILING
CONCRETE SLAB
BOTTOM ROOF STRUCTURE
CONT. 18GA. BOTTOM
TRACK w/ .145" x 1 1/4" MIN.
HILTI FASTENERS @ 16"
O.C. MAX.
(ICC ESR 1663)
-
16
20 GA. SLOTTED SLIP
TRACK
1/
2
"
16GA. SLOTTED TOP CHANNEL TRACK
w/ (2) #10 TEX SCREWS AT 16" O.C.
6"
T
Y
P
.
1'
-
6
"
DU
R
O
C
K
20 GA. 4" OR 6" METAL STUDS @
16" O.C. SEE PLAN
5/8" TYPE "X" GYPSUM BOARD
·6" ABOVE LAY-IN CEILINGS,
·END AT GYP. BOARD CEILINGS
·FULL HEIGHT AT OPEN CEILINGS
A8.2
5
WALL BASE DETAIL 3" = 1'-0"
SCALE
SCHED. WALL
SEE WALL TYPES
00_WALL BASE_
(E) CONCRETE SLAB
FINISH PER
SCHEDULE
CONTINUOUS METAL
BOTTOM TRACK w/ .145"
x 1 1/4" MIN. HILTI X-U
FASTENERS @ 16" O.C.
MAX. ESR 2269, LARR
25675
KITCHEN
4"
1/2" CONTINUOUS
SEALANT
6"
SCHEDULED WALL
BASE SEE FINISH
FLOOR PLAN FOR
SPECS.
SCHEDULED BASE,
SEE FINISH FLOOR
PLAN FOR SPECS.
FRP
4
4
30x48
5'-0"10'-8"
2'
-
6
"
27
"
M
I
N
.
CL
E
A
R
9"
28
"
M
I
N
34
"
M
A
X
.
19"
MIN.
2'-6"2'-6"2'-10"2'-6"2'-6"2'-10"
3'
-
6
"
EQ EQ
2'-6"
34
"
M
A
X
2'
-
3
"
5'-0"10'-8"
+34"+42"
PLAN VIEW
SECTION (ADA)ELEVATION SECTION
30"W X 24"H
CLEAR SPACE
ACCESSIBLE TABLE
WILL BE ATTACHED TO
THE COMMUNITY TABLE
30"W X 24"H
CLEAR SPACE
COMMUNITY TABLE
INSTALLED BY
MILLWORK VENDOR
POP-UP RECEPTACLES.
SEE ELECTRICAL
POP-UP RECEPTACLES.
SEE ELECTRICAL
A8.2
3
A8.2
4
SCALE
1/2" = 1'-0"COMMUNITY TABLE WITH ADA 2
DE
T
A
I
L
S
A8.2
S H E E T N U M B E R
A2641
Pl
o
t
t
e
d
:
10
/
2
/
2
0
2
5
1
1
:
0
2
P
M
(
la
u
r
e
)
F
i
l
e
:
21
_
a
2
6
4
1
_
a
8
.
1
_
d
e
t
a
i
l
s
.
d
w
g
PROJECT NUMBER
2025.10.03
DATE
R E V I S I O N S
S T A M P
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
P
R
O
J
E
C
T
L
O
C
A
T
I
O
N
C O N S U L T A N T
S
H
E
E
T
T
I
T
L
E
C COPYRIGHT 2025 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.
16
0
1
N
B
R
I
S
T
O
L
S
T
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
6
Kevin MacDonald
801 University Avenue
San Diego, CA 92103
kevin.macdonald@betterbuzzcoffee.com
9431 HAVEN AVENUE, SUITE 212
RANCHO CUCAMONGA, CA 91730
P. 909.259.9971 | F. 909.944.8409
www.AmorArch.com
WEST COAST | CENTRAL | EAST COAST
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
TE
STA RN
FOAOCFLI
AI
LICENSED ARCHITECTWILLIAA.AMOR
DATE
8/31/2027
M
C - 24421
RENEWAL
DATE SIGNED: 10/03/2025
1 1/24/25 PLAN CHECK CORRECTIONS
2 4/1/25 PLAN CHECK CORRECTIONS
3 5/2/25 PLAN CHECK CORRECTIONS
4 10/3/25 CHANGE BULLETIN
FIN. FLR.
0'-0"
COMMUNITY TABLE
SECTION 1" = 1'-0"
SCALE
NOTE:
1.GENERAL CONTRACTOR TO COORDINATE w/ OWNER FOR LED REQUIREMENTS
2.ALL WELDS TO BE SHOP WELDS. ANY FIELD WELDING WILL REQUIRE INSPECTION.
CONT. METAL T&B TRACK
HSS 4 x2x3/16" @ 4'-0" O.C.
CONT. 1/2" THICK PLATE
(E) CONC. SLAB
.145" x 1 1/4" MIN. HILTI X-U
FASTENERS @ 16" O.C. MAX.
ESR 2269, LARR 25675
1"
1"
6" SQ.X1/2" BASE PLATE
HSS 4x2x3/16"
A PLAN VIEW
1/4
3"
M
I
N
.
EM
B
E
D
PROVIDE POWER
FOR RECEPTACLE
2'-6"
TABLETOP6"℄
TOP &
BOT.1/4
1'-0"1'-0"
3'
-
6
"
34
"
M
A
X
.
28
"
M
I
N
FINISH FLOOR
0'-0"
CONC. FLOOR
ACCESSIBLE COMMUNITY
TABLE SECTION 1" = 1'-0"
SCALE
PROVIDE POWER
FOR RECEPTACLE
2'-6"
CONT. METAL TOP &
BOTTOM TRACK
1'-3"1'-3"
TABLETOP6"
CONT. 1/2" THICK PLATE℄
TOP &
BOT.
HSS 4x2x3/16" @4'-0" O.C.
6" SQ.x1/2" BASE W/
DRILL AND (4) 1/2"Ø
EPOXY ANCHORS
(HILTI HIT-HY 200,
ICC ESR-3187)
3"
M
I
N
.
EM
B
E
D
1/4
A
1"
1"
6" SQ.X1/2" BASE PLATE
HSS 4x2x3/16"
A PLAN VIEW
1/4
NOTE:
FOR TOE & KNEE
CLEARANCES SEE SHEET T1.3
1'-0"1'-0"
34
4
5'
-
8
"
3'-0"
LOCKNET
HARDWARE SET
3'-0"
(E
)
7
'
-
0
"
7'
-
0
"
10
"
10
"
TYPE A
(N) STOREFRONT
TYPE D
(N) METAL DOOR
TYPE C
(N) SOLID CORE DOOR
1-3/4" BIRCH
NOTE:
CONTRACTOR TO FIELD VERIFY DIMENSIONS.
TYPE B
(N) STOREFRONT
ELIASONELIASON
6'-0"
7'
-
0
"
TYPE E
(N) SOLID CORE DOOR
1-3/4" BIRCH
TEMPERED
GLASS
SEE SCHEDULE
TEMPERED
GLASS
10
"
8'
-
0
"
TYPE F
(N) SOLID CORE DOOR
TEMPERED
GLASS
3'-0"
10
"
SEE PLAN
2'
-
9
"
4'
-
6
"
4'-0"
R.O.
VIEW FROM EXTERIOR
BP-7241E Cali 432 DRIVE-THRU WINDOW
OPENING TO BE A MAXIMUM OF 432 SQ.
FINISH FLOOR
SE
E
E
L
E
V
A
T
I
O
N
S
MA
T
C
H
E
X
I
S
T
I
N
G
H
T
.
A
N
D
F
I
N
I
S
H
E
S
SEE PLAN
FINISH FLR.
TEMP TEMP
SERVICE OPENING:
29 1/2" (W) X 14" (H) =413 sq
MAX. 432 sq.
ADDITIONAL PANEL AT
EXTERIOR SIDE BY MFR.
(BP-7241E-CA)
DRIVE-THRU WINDOW:
29 1/2"x14" SERVICE OPENING WILL MANUF. TO MEET THE MAX.
ALLOWABLE OPENING. THE SERVICE OPENING SHALL NOT BE CLOSER
TOGETHER THAN 18". EACH OPENING SHALL BE PROVIDED WITH A
SOLID OR SCREENED WINDOW, EQUIPPED WITH A SELF-CLOSING
DEVICE. SCREENING SHALL BE AT LEAST 16 MESH PER SQUARE INCH.
PASS OR DRIVE THOUGH WINDOWS OF UP TO 432 SQ. SHOULD BE
EQUIPPED WITH AN AIR CURTAIN DEVICE.
AIR CURTAIN SEE K1.1
TYPE A TYPE B
SE
E
E
L
E
V
A
T
I
O
N
S
MA
T
C
H
E
X
I
S
T
I
N
G
H
T
.
A
N
D
F
I
N
I
S
H
E
S
SEE PLAN
FINISH FLR.
TEMP
TYPE DTYPE C
FINISH FLR.
12
'
-
0
"
12'-4"
EQ 6'-0"EQ
3'
-
1
1
"
8'
-
1
"
SEE DOOR SCHEDULE
3'
-
0
"
3'
-
6
"
F
O
R
C
3'
-
0
"
DIVISION 8: DOORS, WINDOWS AND GLASS
SECTION 8B: INTERIOR WOOD CORE DOORS AND FRAMES
GENERAL PROVISIONS
1.SCOPE: FURNISH AND INSTALL ALL INTERIOR WOOD CORE DOORS AND RELATED
ALUMINUM FRAMES. REFER TO NATIONAL ACCOUNT DIRECTORY.
MATERIALS
1.DOORS ARE WOOD CORE SOLID DOORS. SEE DOOR SCHEDULE FOR SIZE,
MATERIAL, HARDWARE, AND FINISH. FRAMES SHALL BE HOLLOW METAL AND
FINISHED PER FINISH SCHEDULE.
2.SEE HARDWARE SCHEDULE FOR HARDWARE AND MANUFACTURERS.
3.SEE SECTION 10A FOR TOILET STALL DOORS WHERE APPLICABLE.
PERFORMANCE
1.INSTALLATION: INSTALL IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS. CAULK AROUND ABUTTING EDGES WITH CLEAR SILICONE.
SECTION 8C: STEEL DOORS AND FRAMES
GENERAL PROVISIONS
1. SCOPE: THE GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, AND
APPLICABLE PORTIONS OF DIVISION I OF THE SPECIFICATIONS ARE PART OF THIS
SECTION.
2. FURNISH AND INSTALL ALL STEEL DOORS AND FRAMES, COMPLETE WITH JAMB
ANCHORS.
MATERIALS
1. DOORS AND FRAMES BY PIONEER INDUSTRIES, INC., STEELCRAFT, OR CECO.
DOOR FRAMES SHALL BE OF 16 GAUGE COLD ROLLED STEEL. THEY SHALL BE
MITERED AND WELDED AT CORNERS. FRAMES SHALL BE FURNISHED FACTORY-
PRIMED AND SHALL HAVE THREE (3) "T" TYPE JAMB ANCHORS FOR EACH SIDE OF EACH
FRAME. CAULK AROUND ALL ABUTTING EDGES WITH CLEAR SILICONE.
DOORS SHALL BE CONSTRUCTED OF TWO (2) SHEETS OF 18 GAUGE COLD ROLLED
STEEL, WITH VERTICAL STIFFENERS NOT OVER 6" APART AND TOP AND BOTTOM EDGES
REINFORCED HORIZONTALLY BY STEEL CHANNELS, JOINTS AT EDGES OF DOOR SHALL
BE CONTINUOUSLY WELDED. DOORS SHALL BE SOUND DEADENED BY FILLING CORE
WITH MINERAL WOOL INSULATION. THEY SHALL BE THOROUGHLY CLEANED OF
GREASE AND OTHER IMPURITIES, FILLED FLUSH, AND GIVEN TWO (2) COATS OF
BAKED-ON RUST RESISTANT METALLIC PRIMER.
2. SEE HARDWARE SCHEDULE FOR HARDWARE AND MANUFACTURERS.
SPECIFICATIONS
1.COMPLETE SUBMITTALS ARE REQUIRED FOR APPROVAL PRIOR TO ANY ORDERING/ WORK
2.G.C. TO VERIFY THAT EXISTING DOORS TO REMAIN ARE IN GOOD WORKING CONDITION.
AND SHALL KEEP THE EXISTING HARDWARE U.N.O. OR FOUND TO NOT FUNCTION
PROPERLY.
3.NEW BEST LOCK LEVER TYPE HARDWARE, FINISH TO MATCH EXISTING. G.C. TO VERIFY IN
FIELD.
4.EXIT DOORS SHALL BE OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY
OR SPECIAL KNOWLEDGE OR EFFORT. CBC 1010.1.9
5.G.C. TO PROVIDE SIGNAGE ON PRIMARY EGRESS DOORS STATING "THIS DOOR TO REMAIN
UNLOCKED WHEN THIS SPACE IS OCCUPIED."
6.ALL FINISH HARDWARE TO COMPLY WITH ALL GOVERNING AND ACCESSIBILITY CODES.
7.ALL DOOR EDGES SHALL BE PRIMED AND PAINTED. VERIFY COLOR WITH INTERIOR
ELEVATIONS.
8.PROVIDE A FLOOR MOUNTED DOOR STOP FOR DOORS THAT SWING AGAINST THE WALL.
9.ALL DOOR SILENCERS SHALL BE INSTALLED AFTER DOOR AND FRAME HAVE RECEIVED
FINAL PAINTED.
10.INSTALL CAULKING AROUND DOOR FRAME JAMBS, HEAD AND AT BOTTOM OF FRAME.
SEAL BOTTOM OF WOOD DOORS.
11.DOOR OPENING FORCE: FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE
ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE MAXIMUM FORCE
FOR PUSHING OR PULLING OPEN, EXTERIOR OR INTERIOR HINGED DOORS w/ CLOSER AND
SLIDING OR FOLDING DOORS, SHALL NOT EXCEED FIVE POUNDS (22.2 N) MAXIMUM.
12.OVERHEAD AUTOMATIC SWITCH AIR CURTAINS MUST BE PROVIDED AT ALL DELIVERY
DOORS. THE AIR CURTAIN WILL PRODUCE AN AIR FLOW (8) EIGHT INCHES THICK AT THE
DISCHARGE OPENING AND WITH AN AIR VELOCITY OF NOT LESS THAN 1600 FPM (FEET PER
MINUTE) ACROSS THE ENTIRE OPENING MEASURED AT THREE (3) FEET BELOW THE AIR
CURTAIN.
13.HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES
THAT ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT
REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. (11B-309.4). OPERABLE
PARTS OF SUCH HARDWARE SHALL BE 34" MINIMUM AND 44" MAXIMUM ABOVE THE FINISH
FLOOR OR GROUND (11B-404.2.7)
14.ALL NEW DOORS MUST BE EQUIPPED WITH LEVEL TYPE HANDLE.
15.DOOR AND FRAME SHALL BE FULLY ASSEMBLED AND ALL HARDWARE SHALL BE
INSTALLED BY SKILLED CRAFTSMEN AT THE FACTORY AND THE UNIT DELIVERED TO THE
JOBSITE READY FOR INSTALLATION. THE DOOR, HARDWARE AND THE HARDWARE
INSTALLATION SHALL CARRY A MANUFACTURER'S 14-MONTH WARRANTY W/ 24 HOUR
SERVICE. (TOLL FREE NUMBER TO BE DISPLAYED ON DOOR). DOORS TO BE FACTORY
FINISHED IN DARK BRONZE.
16.H4101 FLUSH BOLT ON INACTIVE LEAF OF PAIR ONLY.
DOOR NOTES AND HARDWARE
DOOR HINGES: USE 3-1/2" SCREWS (ALL HARDWARE TO BE STAINLESS STEEL)
SIGNAGE: "MEN" / "WOMEN" / "UNISEX" ON TOILET ROOM DOOR
SIGNAGE: "EMPLOYEE ONLY" ON PASSAGE DOOR
DOOR CLOSER: LCN 1460 ALUMINUM CLOSER
RESTROOMS THAT OPEN INTO A RETAIL FOOD ESTABLISHMENT MUST BE COMPLETELY
ENCLOSED WITH SELF-CLOSING DOORS.
1
2
3
4
5
WITH TEMPERED VISION LIGHT
KICK PLATE, FULL WIDTH OF DOOR @ 10 INCH MIN HT. AT BASE
PROVIDE ACCESSIBLE IDENTIFICATION SYMBOLS
6
7
8
9 SEE FINISH SCHEDULES FOR PAINT COLOR
10
11
AIR CURTAIN
12
PROVIDE DECAL "NO DELIVERIES, USE BACK DOOR"
13
PROVIDE (HAGER, 4500 SERIES) PANIC HARDWARE TO EXIT DOOR. PANIC HARDWARE
SHALL COMPLY WITH FIRE MARSHALS REQUIREMENTS.
14
INSULATED DOOR BY WALK-IN COMBO MANUFACTURER
15
PROVIDE DECAL "ALL DELIVERIES AT THIS DOOR"
EXTERIOR DOORS ARE SELF-CLOSING, AND RODENT PROOFED
REMARK NOTES
16 PROVIDE PRIVACY DEADBOLT WITH OCCUPANCY INDICATOR
17
PROVIDE SIGN "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED"
ABOVE DOOR. SIGN TO BE 1 INCH (25MM) HIGH AND IN CONTRASTING COLORS WITH
BACKGROUND. SIGN TO BE ILLUMINATED
DO
O
R
S
C
H
E
D
U
L
E
A9.1
MARK SIZE DOOR
DOORS BY COOLER MANUFACTURER
HD
W
R
.
S
E
T
PU
S
H
/
P
U
L
L
VI
E
W
E
R
KI
C
K
P
L
A
T
E
PA
N
I
C
LO
U
V
E
R
S
WE
A
T
H
E
R
-
ST
R
I
P
P
I
N
G
LO
C
K
S
E
T
CL
O
S
E
R
TH
R
E
S
H
ST
O
P
BU
T
T
S
FRAME
DETAIL
QUANTITY
FRAME
REMARKS
11 15
102
103
104
105
101
13
DOOR SCHEDULE
DOOR TYPES
SCALE 3N.T.S.
106
11 15
107
WINDOW TYPES
SCALE 12N.T.S.8 4
HARDWARE SET NO. 1:
1-1/2 PR. HINGES McKINNEY BEARING HINGES, 4-1/2" X 4-1/2" US26D
1 EA. PULL/PUSH HANDLE SCHLAGE
1 EA. FLOOR STOP BALDWIN #4000 FLOOR MOUNT
1 EA. KICKPLATE BURNS 8" X 30" X 8" 16GA. US628
1 EA. CLOSER LCN 1460 ALUMINUM CLOSER
FOLLOWING ITEMS PROVIDED & INSTALLED BY G.C.:
1 EA. SIGN HANDICAP ACCESSIBILITY (ADA)
1 EA. SIGN AS REQD: "MEN" 7" X 2"
"WOMEN" 7" X 2"HARDWARE SET NO. 2:
1-1/2 PR. HINGES McKINNEY BEARING HINGES, 4-1/2" X 4-1/2" US26D
1 EA. KICKPLATE BURNS 8" X 30" X 8" 16GA. US26D
1 EA. LATCHSET W/LOCK SCHLAGE SATURN X US26D
1 EA. 6"x6" VIEWING WINDOW
1 EA. CLOSER LCN 1460 ALUMINUM CLOSER
DOOR HARDWARE
S H E E T N U M B E R
A2641
Pl
o
t
t
e
d
:
10
/
2
/
2
0
2
5
1
1
:
0
2
P
M
(
la
u
r
e
)
F
i
l
e
:
22
_
a
2
6
4
1
_
a
9
.
1
_
d
o
o
r
s
c
h
e
d
u
l
e
.
d
w
g
PROJECT NUMBER
2025.10.03
DATE
R E V I S I O N S
S T A M P
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
P
R
O
J
E
C
T
L
O
C
A
T
I
O
N
C O N S U L T A N T
S
H
E
E
T
T
I
T
L
E
C COPYRIGHT 2025 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.
16
0
1
N
B
R
I
S
T
O
L
S
T
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
6
Kevin MacDonald
801 University Avenue
San Diego, CA 92103
kevin.macdonald@betterbuzzcoffee.com
9431 HAVEN AVENUE, SUITE 212
RANCHO CUCAMONGA, CA 91730
P. 909.259.9971 | F. 909.944.8409
www.AmorArch.com
WEST COAST | CENTRAL | EAST COAST
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
TE
STA RN
FOAOCFLI
AI
LICENSED ARCHITECTWILLIAA.AMOR
DATE
8/31/2027
M
C - 24421
RENEWAL
DATE SIGNED: 10/03/2025
1 1/24/25 PLAN CHECK CORRECTIONS
2 4/1/25 PLAN CHECK CORRECTIONS
3 5/2/25 PLAN CHECK CORRECTIONS
4 10/3/25 CHANGE BULLETIN
MARK SIZE TYPE GLAZING
WINDOW SCHEDULE
A
B
C
D
E
16
OPERABLE FRAME
FINISH
FRAME
MATERIAL REMARKS
F
17
17
EXTERIOR DOOR JAMB 3" = 1'-0"
SCALE
2"
HOLLOW METAL FRAME
ACCESS DOOR
SEE DOOR SCHEDULE
SEALANT & BACK ROD
EACH SIDE, CONT.
DBL 2x6 JAMB
5/8" GYPSUM BOARD
SEE FINISH SCHEDULE
INTERIOREXTERIOR
6"
EXISTING AND/OR
NEW 6" WINDOW TRIM
WHERE OCCURS
2 LAYERS GRADE 'D' OR 60
MIN.GRADE 'D' MIN
MOISTURE BARRIER(BLDG
PAPER) TYPICAL BEHIND
STUCCO & STONE VINEER
2x6 STUD WALL
@ 16" O.C.
FOAM SHAPE
EXTERIOR DOOR HEAD 3" = 1'-0"
SCALE
2"
HOLLOW METAL FRAME
ACCESS DOOR
SEE DOOR SCHEDULE
SEALANT & BACK ROD
EACH SIDE, CONT.
6x HEADER
5/8" GYPSUM BOARD
SEE FINISH SCHEDULE
INTERIOREXTERIOR
6"
EXISTING AND/OR
NEW 6" WINDOW TRIM
WHERE OCCURS
2x6 STUD WALL
@ 16" O.C.
FOAM SHAPE
2 LAYERS GRADE 'D' OR 60
MIN.GRADE 'D' MIN
MOISTURE BARRIER(BLDG
PAPER) TYPICAL BEHIND
STUCCO & STONE VINEER
910
2"2"
PARTITION
WIDTH
INTERIOR DOOR HEAD 3" = 1'-0"
SCALE
5/8" GYP. BD.
EA. SIDE
EXTEND GYP. BD.
INTO FRAME 5/8" MIN.
JAMB ANCHOR
HOLLOW METAL
FRAME
DOOR - PER SCHEDULE
STANDARD RABBET
2"
5/
8
"
5/
8
"
M
I
N
.
(T
Y
P
.
)
1/2" EA.
SIDE (TYP.)
BOX HEADER
SEE 5/ A7.1
5/8"2"
5/8" MIN.
(TYP.)
PA
R
T
I
T
I
O
N
WI
D
T
H
1/
2
"
EA
C
H
S
I
D
E
2"
2"
5/8" GYPSUM BOARD
EACH SIDE
HOLLOW
METAL FRAME
DOOR - PER
SCHEDULE
INTERIOR DOOR JAMB 3" = 1'-0"
SCALE
DOUBLE
METAL STUDS
4
NO
PA
R
K
I
N
G
EV
EV
EV
SECONDARY CONDUIT WITH PULL STRINGS TO UTILITY POWER
COMPANY TRANSFORMER
(VERIFY AND COORDINATE WITH SCE DESIGN FOR
REQUIREMENTS AND DETAILS)
2" EMPTY CONDUIT WITH PULL
STRING TO TELECOM
P.D.C.(VERIFY AND
COORDINATE)
'MDB'
1" C TO D.T.
WINDOW
1"C TO 'C'
J
J
MENU BOARD
AND SPEAKER
1"C TO 'C'
J
PRE-ORDER
BOARD
DT SIGN J
1"C, PROVIDE PULL STRING
(TYP. FOR PARKING LOT
LIGHTING AND DT SIGN CIRCUITS)
HP-3
'F'
'F'
'F'
'F''F'
'F'
'F''F'
'F'
'F''F'
'F'
SITE DEVELOPMENT
UNDER SEPARATE PERMIT
HP-1 - (2#10 + #12 GND. CU)
PANEL 'B'
PANEL 'HP'
B-70
HP-12,14
B-84
HP-8,10
B-78
B-72
HP-4,6
1.REFER TO E0.1 FOR ADDITIONAL GENERAL NOTES.
2.FIELD VERIFY EXACT LOCATION & ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL
CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT.
3.ALL CONDUIT FOR THE CAT5 (TELEPHONE) SHALL BE EMT - NO FLEX CONDUIT.
4.COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD. WRITTEN PERMISSION FROM THE LANDLORD
SHALL BE RECEIVED PRIOR TO ANY WORK BEING PERFORMED. ALL ROOF PENETRATIONS TO BE BY
LANDLORD'S CONTRACTOR AT TENANT'S ELECTRICAL CONTRACTOR'S EXPENSE.
5.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL COMMUNICATION WIRING. ALL CABLING SHALL BE BLUE
PLENUM RATED CAT5e. ALL CABLE & TERMINATION SHALL BE TESTED & LABELED AT BOTH ENDS. THE
ELECTRICAL CONTRACTOR SHALL TERMINATE ALL WIRING AT OUTLET LOCATIONS ON PLANS & CONNECT
ALL WIRING TO THE PATCH PANEL FOR ALL COMMUNICATIONS. THE OWNER WILL CONNECT PATCH PANEL
TO SERVER.
6.ALL COMMUNICATION OUTLETS SHALL HAVE A 1" CONDUIT STUB UP TO ACCESSIBLE CEILING SPACE FOR
DATA WIRING. PROVIDE INSULATED BUSHING AT EACH CONDUIT END. VERIFY EXACT LOCATION WITH
ARCHITECT PRIOR TO INSTALLATION. CONNECT ALL CABLES INTO IT SPACE.
7.ANY BRANCH CIRCUIT THAT SERVE NEW AIR COMPRESSORS, SHALL HAVE A "FULL SIZED" NEUTRAL
CONDUCTOR (MATCHING THE CONDUCTOR SIZE OF THE CURRENT CARRYING CONDUCTORS INSTALLED).
8.ALL UNDERGROUND CONDUITS SHALL BE INSTALLED IN ACCORDANCE WITH N.E.C. 300.5.
9.ANY PROPOSED TRENCHING FOR ELECTRICAL CONDUITS SHOWN PLANS SHALL BE CONSIDERED AS
SUGGESTED TRENCH ROUTING - CONTRACTOR TO ADJUST AS REQUIRED DUE TO SITE CONDITIONS.
COORDINATE ROUTING OF ALL UNDERGROUND CONDUITS WITH YOSHINOYA'S CONSTRUCTION MANAGER
PRIOR TO TRENCHING.
10.RECEPTACLES SHALL BE PROTECTED W/ GFCI DEVICES (RECEPTACLE OR BREAKER) CONTRACTOR TO
PROVIDE LOWEST COST SOLUTION. THIS IS TO BE DETERMINED AND VERIFIED BY ELECTRICAL
CONTRACTOR. AS REQUIRED BY CURRENT ADOPTED NEC CODE & ANY LOCAL AMENDMENTS .
EL
E
C
T
R
I
C
A
L
S
I
T
E
P
L
A
N
E1.1
GENERAL NOTES (AS APPLICABLE)
S H E E T N U M B E R
A2641
Pl
o
t
t
e
d
:
10
/
7
/
2
0
2
5
3
:
5
2
A
M
(
me
p
-
1
)
F
i
l
e
:
be
t
t
e
r
b
u
z
z
s
a
n
t
a
a
n
a
c
a
_
e
l
e
c
t
r
i
c
a
l
s
e
t
.
d
w
g
PROJECT NUMBER
2024.06.27
DATE
R E V I S I O N S
S T A M P
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
P
R
O
J
E
C
T
L
O
C
A
T
I
O
N
C O N S U L T A N T
S
H
E
E
T
T
I
T
L
E
C COPYRIGHT 2024 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.
16
0
1
N
B
R
I
S
T
O
L
S
T
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
6
Kevin MacDonald
801 University Avenue
San Diego, CA 92103
kevin.macdonald@betterbuzzcoffee.com
9431 HAVEN AVENUE, SUITE 212
RANCHO CUCAMONGA, CA 91730
P. 909.259.9971 | F. 909.944.8409
www.AmorArch.com
WEST COAST | CENTRAL | EAST COAST
909-997-0905
CARLOS RIVAS
carlos@rivasdesignconsultants.com
MECHANICAL I ELECTRICAL I PLUMBING
TE
STA RNFOAOCFLI
AI
LICENSED ARCHITECTWILLIAA.AMOR
DATE
8/31/2027
M
C - 24421
RENEWAL
2025-02-05 PLAN CHECK CORRECTIONS1
2025-04-07 PLAN CHECK CORRECTIONS2
2025-10-06 ELECTRICAL CLARIFICATIONS3
ELECTRICAL SITE PLAN 1SCALE
1" = 10'-0"
N
KEYNOTESKEYNOTES
3
3
BA
K
E
R
Y
CA
S
E
28
"
X
2
5
"
KOBILE
PICK-UP SHELVES
GRAB-N-GO
1
2
3.2
5
6
E C.1 B AF
E D C B AF
1
2
4
5
6
3
ENTRY
EN
T
R
Y
18
x
4
8
5-
t
i
e
r
18
x
4
2
18x60
5-tier
18
x
4
8
5-
t
i
e
r
18
x
4
2
18x60
5-tier
18x60
5-tier
18
x
3
6
5-
t
i
e
r
18x60
5-tier
18x60
5-tier
18x60
5-tier
18x60
5-tier
18x60
5-tier
18
x
3
6
5-
t
i
e
r
BAKERY CASE
BA
K
E
R
Y
CA
S
E
28
"
X
2
5
"
KOBILE
PICK-UP SHELVES
GRAB-N-GO
1
2
3.2
5
6
E C.1 B AF
E D C B AF
1
2
4
5
6
3
ENTRY
EN
T
R
Y
18
x
4
8
5-
t
i
e
r
18
x
4
2
18x60
5-tier
18
x
4
8
5-
t
i
e
r
18
x
4
2
18x60
5-tier
18x60
5-tier
18
x
3
6
5-
t
i
e
r
18x60
5-tier
18x60
5-tier
18x60
5-tier
18x60
5-tier
18x60
5-tier
18
x
3
6
5-
t
i
e
r
BAKERY CASE
J
J
J
1
1
2
TE
L
E
.
JJ
J
J
J
J
3
3
3
3
3
3
4
4
4
4
JJ
3 3
J4
6
5
J
B-27 B-29
B-58
B-11J
B-35
B-38,40,42
B-7
'B''HP'
B-56
A-30
A-32
A-10,12
A-14,16
A-18,20
A-22,24
A-26,28
B-52
B-54
A-8
B-3
B-1
A-41
A-39
A-37
B-5
B-55
A-21,23
A-15,17
B-53
B-49
B-47 B-51
B-48
B-46
B-45
A-1
B-43
B-44
A-3
B-23,25
A-5
B-19
B-17
A-36,38
B-50
A-33,35A-19
A-27
A-31
A-25
C-15
A-11 A-4 A-2
A-6
A-11
A-13
B-60
'A'B-68
7
A-49
A-49
A-49
A-49
A-49
A-49
1.REFER TO E0.1 FOR ADDITIONAL GENERAL NOTES.
2.FIELD VERIFY EXACT LOCATION & ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL
CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT.
3.ALL CONDUIT FOR THE CAT5 (TELEPHONE) SHALL BE EMT - NO FLEX CONDUIT.
4.COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD. WRITTEN PERMISSION FROM THE LANDLORD
SHALL BE RECEIVED PRIOR TO ANY WORK BEING PERFORMED. ALL ROOF PENETRATIONS TO BE BY
LANDLORD'S CONTRACTOR AT TENANT'S ELECTRICAL CONTRACTOR'S EXPENSE.
5.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL COMMUNICATION WIRING. ALL CABLING SHALL BE BLUE
PLENUM RATED CAT5e. ALL CABLE & TERMINATION SHALL BE TESTED & LABELED AT BOTH ENDS. THE
ELECTRICAL CONTRACTOR SHALL TERMINATE ALL WIRING AT OUTLET LOCATIONS ON PLANS & CONNECT
ALL WIRING TO THE PATCH PANEL FOR ALL COMMUNICATIONS. THE OWNER WILL CONNECT PATCH PANEL
TO SERVER.
6.ALL COMMUNICATION OUTLETS SHALL HAVE A 1" CONDUIT STUB UP TO ACCESSIBLE CEILING SPACE FOR
DATA WIRING. PROVIDE INSULATED BUSHING AT EACH CONDUIT END. VERIFY EXACT LOCATION WITH
ARCHITECT PRIOR TO INSTALLATION. CONNECT ALL CABLES INTO IT SPACE.
7.ANY BRANCH CIRCUIT THAT SERVE NEW AIR COMPRESSORS, SHALL HAVE A "FULL SIZED" NEUTRAL
CONDUCTOR (MATCHING THE CONDUCTOR SIZE OF THE CURRENT CARRYING CONDUCTORS INSTALLED).
8.ALL UNDERGROUND CONDUITS SHALL BE INSTALLED IN ACCORDANCE WITH N.E.C. 300.5.
9.ANY PROPOSED TRENCHING FOR ELECTRICAL CONDUITS SHOWN PLANS SHALL BE CONSIDERED AS
SUGGESTED TRENCH ROUTING - CONTRACTOR TO ADJUST AS REQUIRED DUE TO SITE CONDITIONS.
COORDINATE ROUTING OF ALL UNDERGROUND CONDUITS WITH YOSHINOYA'S CONSTRUCTION MANAGER
PRIOR TO TRENCHING.
10.RECEPTACLES SHALL BE PROTECTED W/ GFCI DEVICES (RECEPTACLE OR BREAKER) CONTRACTOR TO
PROVIDE LOWEST COST SOLUTION. THIS IS TO BE DETERMINED AND VERIFIED BY ELECTRICAL
CONTRACTOR. AS REQUIRED BY CURRENT ADOPTED NEC CODE & ANY LOCAL AMENDMENTS .
EL
E
C
T
R
I
C
A
L
P
O
W
E
R
P
L
A
N
E2.1
GENERAL NOTES (AS APPLICABLE)
S H E E T N U M B E R
A2641
Pl
o
t
t
e
d
:
10
/
7
/
2
0
2
5
3
:
4
5
A
M
(
me
p
-
1
)
F
i
l
e
:
be
t
t
e
r
b
u
z
z
s
a
n
t
a
a
n
a
c
a
_
e
l
e
c
t
r
i
c
a
l
s
e
t
.
d
w
g
PROJECT NUMBER
2024.06.27
DATE
R E V I S I O N S
S T A M P
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
P
R
O
J
E
C
T
L
O
C
A
T
I
O
N
C O N S U L T A N T
S
H
E
E
T
T
I
T
L
E
C COPYRIGHT 2024 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.
16
0
1
N
B
R
I
S
T
O
L
S
T
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
6
Kevin MacDonald
801 University Avenue
San Diego, CA 92103
kevin.macdonald@betterbuzzcoffee.com
9431 HAVEN AVENUE, SUITE 212
RANCHO CUCAMONGA, CA 91730
P. 909.259.9971 | F. 909.944.8409
www.AmorArch.com
WEST COAST | CENTRAL | EAST COAST
909-997-0905
CARLOS RIVAS
carlos@rivasdesignconsultants.com
MECHANICAL I ELECTRICAL I PLUMBING
TE
STA RNFOAOCFLI
AI
LICENSED ARCHITECTWILLIAA.AMOR
DATE
8/31/2027
M
C - 24421
RENEWAL
2025-02-05 PLAN CHECK CORRECTIONS1
2025-04-07 PLAN CHECK CORRECTIONS2
2025-10-06 ELECTRICAL CLARIFICATIONS3
ELECTRICAL POWER PLAN 1/4" = 1'-0"1SCALE
1/4" = 1'-0"
N
KEYNOTES
1
KEYNOTES
1 (N) ELECTRICAL PANEL, SEE ELECTRICAL DRAWINGS
2 MAIN SWITCHBOARD
3 JUNCTION BOX FOR SIGNAGE
4 RECESSED MOUNT 20A DUPLEX GFI POP-UP RECEPTACLES W/ 20USB CHARGING PORT
5 LIGHTING CONTROL PANEL
6 TELEPHONE TERM BACKBOARD
LEGEND
DATA POINT OF CONNECTION
PHONE JACK
(E) DENOTES EXISTING DEVICE TO REMAIN
(D) DENOTES EXISTING DEVICE TO BE DEMOLISHED
(N) DENOTES NEW DEVICE
(R) DENOTES DEVICE TO BE RELOCATED.
J JUNCTION BOX
TV TELEVISION JACK
LEGEND
COMBO PHONE AND DATA RECEPTACLE MOUNTED
FLUSH
SINGLE RECEPTACLE
(E) DENOTES EXISTING DEVICE TO REMAIN
(D) DENOTES EXISTING DEVICE TO BE DEMOLISHED
(R) DENOTES DEVICE TO BE RELOCATED.
J
TV
DUPLEX RECEPTACLE
QUAD RECEPTACLE
ISOLATED GROUND DUPLEX RECEPTACLE
HIGH VOLTAGE RECEPTACLE
ELECTRICAL INTERCONNECTION
7 ALL 120V AND 240V KITCHEN OUTLETS SHALL BE GFCI PROTECTED
(C) DENOTES NEW DEVICE IN CEILING
3
1. FIELD VERIFY MINIMUM AIC RATINGS OF EXISTING ELECTRICAL EQUIPMENTS.
2. ADJUST CIRCUITING ON PANELBOARDS AS REQUIRED TO MAINTAIN MAXIMUM 10% LOAD IMBALANCE.
3. PROVIDE A COMPLETE TYPED DIRECTORY IN EACH PANELBOARD TO INCLUDE EXISTING LOADS TO
REMAIN AS WELL AS NEW LOADS. DIRECTORY SHALL INDICATE EQUIPMENT NAME AND/OR
ROOM NUMBER OF EQUIPMENT OR DEVICES FOR BOTH NEW AND EXISTING LOADS PER NEC 408.4.
4. PANELBOARDS IDENTIFICATION LABEL SHALL INCLUDE THE NAME WHERE POWER SUPPLY
ORIGINATES PER NEC 408.4.
5. CIRCUIT BREAKERS SERVING FIRE ALARM SYSTEM PANELS AND POWER SUPPLIES SHALL BE IDENTIFIED
AS FIRE ALARM, PROVIDED WITH LOCK ON DEVICE, AND HAVE A RED COLORED HANDLE OR PAINTED
RED.
6. FIELD VERIFY AVAILABLE FAULT CURRENT AT SERVICE ENTRANCE WITH UTILITY COMPANY PRIOR TO
PROCUREMENT OF ELECTRICAL DISTRIBUTION EQUIPMENT AND VERIFY MINIMUM FAULT INTERRUPTING
RATINGS OF MAIN SWICTHBOARD AND BRANCH PANELBOARD.
7. ALL OVERCURRENT DEVICES IN AN INDIVIDUAL PIECE OF EQUIPMENT SHALL HAVE AN AIC RATING
EQUAL TO THE OVERALL RATING OF THE EQUIPMENT.
8. ALL TERMINATIONS AND ENCLOSURES SHALL BE RATED FOR USE WITH 75 DEGREE CELSIUS
CONDUCTORS.
9. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHBOARDS, DISTRIBUTION BORADS, AND PANELBOARDS
RATED AT 400AMPS OR GREATER, SHALL BE PROVIDED WITH A MAIN OVERCURRENT DEVICE AND
BUSSING RATED AT 100% CONTINUOUS OPERATION.
10. ALL BRANCH OR FEEDER CIRCUIT OVER CURRENT DEVICES RATED AT 400AMPS OR HIGHER SHALL BE
RATED FOR 100%
EL
E
C
T
R
I
C
A
L
S
I
N
G
L
E
L
I
N
E
A
N
D
P
A
N
E
L
S
C
H
E
D
U
L
E
E4.1
GENERAL NOTES (AS APPLICABLE)
S H E E T N U M B E R
A2641
Pl
o
t
t
e
d
:
11
/
7
/
2
0
2
5
8
:
2
0
A
M
(
cr
i
v
a
)
F
i
l
e
:
be
t
t
e
r
b
u
z
z
s
a
n
t
a
a
n
a
c
a
_
e
l
e
c
t
r
i
c
a
l
s
e
t
.
d
w
g
PROJECT NUMBER
2024.06.27
DATE
R E V I S I O N S
S T A M P
SHEETS BEARING THIS SEAL AND WET SIGNATURE
ARE AUTHENTICATED. RESPONSIBILITY FOR ALL
OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS
ARE DISCLAIMED.
P
R
O
J
E
C
T
L
O
C
A
T
I
O
N
C O N S U L T A N T
S
H
E
E
T
T
I
T
L
E
C COPYRIGHT 2024 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.
16
0
1
N
B
R
I
S
T
O
L
S
T
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
6
Kevin MacDonald
801 University Avenue
San Diego, CA 92103
kevin.macdonald@betterbuzzcoffee.com
9431 HAVEN AVENUE, SUITE 212
RANCHO CUCAMONGA, CA 91730
P. 909.259.9971 | F. 909.944.8409
www.AmorArch.com
WEST COAST | CENTRAL | EAST COAST
909-997-0905
CARLOS RIVAS
carlos@rivasdesignconsultants.com
MECHANICAL I ELECTRICAL I PLUMBING
TE
STA RN
FOAOCFLI
AI
LICENSED ARCHITECTWILLIAA.AMOR
DATE
8/31/2027
M
C - 24421
RENEWAL
2025-02-05 PLAN CHECK CORRECTIONS1
2025-04-07 PLAN CHECK CORRECTIONS2
2025-10-06 ELECTRICAL CLARIFICATIONS3
2025-11-07 PLAN CHECK CORRECTIONS4
TO UTILITY POWER COMPANY
(VERIFY REQUIREMENTS)
SEE DETAIL
# 2/0
PANEL
'A'
200A
3P
F2004
1
PANEL
'B'
200A
3P
F2004
2
PANEL
'C'
100A
3P
F1004
3
PANEL
'D'
225A
3P
F2254
4
100A
3P
5
600A
3P
PANEL MDB: 600A, 120/208V, 3PH, 4W, 65 KAIC
U
G
P
S
M
EWH-1
COPPER FEEDER SCHEDULE
3PH, 4W, w/ GROUND
FEEDER
F8004
F6004
F4004
F2504
F2254
F2004
F1754
F1504
F1254
F1004
F904
F804
F704
F604
F504
F404
F304
F204
F10004
F12004
F16004
F20004
F30004
F40004
AMPS
20
30
40
50
60
70
80
90
100
125
150
175
200
225
250
400
600
800
1000
1200
1600
2000
3000
4000
CONDUIT
3/4"C
3/4"C
3/4"C
1"C
1"C
1-1/4"C
1-1/4"C
1-1/4"C
1-1/2"C
2"C
2"C
2"C
2"C
2-1/2"C
3"C
4"C
(2) 3"C.
(2) 4"C
(3) 4"C
(4) 3"C
(5) 4"C
(5) 5"C
(8) 5"C
(10) 5"C
CONDUCTOR
4#12
4#10
4#6
4#8
4#4
4#4
4#2
4#2
4#1
4#1/0
4#1/0
4#2/0
4#3/0
4#4/0
4#250KCMIL
4#500KCMIL
4#350KCMIL
4#500KCMIL
4#500KCMIL
4#350KCMIL
4#500KCMIL
4#600KCMIL
4#500KCMIL
4#600KCMIL
GROUND
#12
#10
#10
#10
#10
#8
#8
#8
#8
#6
#6
#6
#6
#4
#4
#2
#1
#1/0
#3/0
#3/0
#4/0
250KCMIL
500KCMIL
500KCMIL
KEYED NOTE:
MAIN BREAKER OF 600A MUST BE ON
CONTINUOUS DUTY RATING1
1
F1004
PANEL
'HP'
225A
3P
F2254
6
1
F3004 300 3"C 4#350KCMIL #4
EV
CAPABLE
SPACES
EV
CAPABLE
SPACES
65
NO
PA
R
K
I
N
G
(E) MCDONALD'S
ZONE: SP1
ZONE: SP1
ZONE: R1
EN
T
R
Y
ENTRY
8
AS2.1
DN
DN
EV
EV
EV
PROPOSED BETTER
BUZZ
WITH DRIVE-THRU
APPROX.
1,753 GROSS S.F.
1,634 NET S.F.
ACCESSIBLE PATH
OF TRAVEL
ACCESSIBLE PATH
OF TRAVEL
65
15'-0"
BLDG SETBACK
41'-3"
10'-2"
25'-0"
174'-6"
STREET FRONTAGE
285'-6"
PTO W. 17TH STREET 10'-1"
10
'
-
2
"
3'
-
2
"
12'-0"
49'-6"16'-0"7'-6"11'-0"3'-6"
45
'
-
1
0
"
5'
-
2
"
12
'
-
0
"
50
'
-
1
0
"
44'-5"
28'-0"
12
'
-
0
"
38'-0"4'-0"4'-0"
11'-0"
13
'
-
2
"
1'
-
6
"
12
'
-
0
"
3'
-
1
0
"
6'
-
4
"
6'
-
6
"
17
'
-
4
"
18'-1"19'-0"
8'
-
7
"
25
'
-
1
1
"
W.
1
7
T
H
S
T
R
E
E
T
8'-0"
13
'
-
4
"
18
'
-
2
"
22'-0"
10'-0"
15'-0"15'-0"
8'
-
6
"
8"
(E) MCDONALD'S
ZONE: SP1
ZONE: SP1
ZONE: R1
R. 20'
R. 20'
R. 20'
R. 20'
R. 20'
(N) "NO LEFT
TURN"