Loading...
HomeMy WebLinkAbout2026 E Kemper Ave - PlanGENERAL NOTES AERIAL VIEW SHEET INDEX PV1 COVER PAGE PV2 SITE PLAN PV3 MOUNTING DETAIL - TLS PV4 ELECTRICAL DIAGRAM PV5 ELECTRICAL CALCS PV6 LABELS PV7 PLACARD REVISION HISTORY CUTSHEETS REV_0 - ORIGINAL PLAN SET VERSION APPLICABLE CODES:DESCRIPTION OF DESIGN: INSTALLATION OF GRID TIED, UTILITY INTERACTIVE PHOTOVOLTAIC SYSTEM EQUIPMENT:DC SYSTEM SIZE:KW BIPV SHINGLE (PV MODULE): AC SYSTEM SIZE:KW INVERTER: ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV 0 KW (DC)KW (AC)DELTA M4-TL-US PV1 GAF ENERGY TLS-2 COVER PAGE BY:Aldortega (30) (1) 1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. 2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. 3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4. IF THE INSTALLATION USES TIMBERLINE SOLAR SHINGLES - THE BIPV SHINGLES (PV MODULES) ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. 5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 6. DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. Santa Ana CA 92705 2026 Kemper Avenue 973-628-3411 5981 Optical Ct B #1062345 C-10 San Jose CA 95138 Lydia Pearson GAF Energy LLC (CA)1.71 4 PROJECT WILL INCLUDE THE COMPLETE REMOVAL OF THE EXISTING ASPHALT ROOF & UNDERLAYMENT 2022 2022 2022 2022 California Electrical Code California Building Code California Residential Code California Fire Code GAF ENERGY TLS-2 DELTA M4-TL-US 1.71 4 (30) (1) 10/21/2025 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 AZIMUTH:°PITCH:/12 ENERGY SHINGLE PART NUMBER:GAF ENERGY TLS-2 ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV 0 KW (DC)KW (AC)DELTA M4-TL-US PV2 GAF ENERGY TLS-2 SITE PLAN BY:Aldortega 10/21/2025 Lydia Pearson GAF Energy LLC (CA)1.71 973-628-3411 5981 Optical Ct2026 Kemper Avenue (30) 4 (1) B #1062345 C-10 San Jose CA 95138Santa Ana CA 92705 166 5.1256 5.1 UTILITY METERM INV MSP AC LC J-BOX BAT PV MAIN SERVICE PANEL LOAD CENTER AC DISCONNECT METER SOCKET (FOR UTILITY PV METER) INVERTER JUNCTION BOX BATTERY(IES) FIRE ACCESS PATHWAY (3' TYP.) EQUIPMENT LEGEND MP#1 ↑ NORTH Pass TOTAL ROOF AREA: 2,427.44 sq ft AREA OF PV MODULES: 102.36 sq ft %OF ROOF COVERED: 4.22% RIDGE SETBACKS 18" MINIMUM MP#2 MP#4 MP#6 MP#7 MP#8 MP#9 MP#10 MP#11 MP#12 MP#3 MP#5 MP#13 MP#14 ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV 0 KW (DC)KW (AC)DELTA M4-TL-US PV3 GAF ENERGY TLS-2 Mounting Detail - TLS BY:Aldortega 2026 Kemper Avenue (30) 10/21/2025 Lydia Pearson GAF Energy LLC (CA)1.71 973-628-3411 5981 Optical Ct 4 (1) Santa Ana CA 92705 B #1062345 C-10 San Jose CA 95138 INSTALLATION NOTES MINIMUM SHEATHING THICKNESS: 7/16" OSB or 15/32" PLYWOOD. FULL TEAR OFF REQUIRED PRIOR TO INSTALLATION TO VERIFY DECKING THICKNESS, CONDITION, AND CODE- COMPLIANT ATTACHMENT TO STRUCTURE. PLEASE SEE ATTACHED STAMPED STRUCTURAL ENGINEERING LETTER FOR ADDITIONAL EXPLANATION REGARDING PE REVIEW/ REQUIREMENTS FOR THE TIMBERLINE SOLAR PRODUCT. BIPV SHINGLES (PV MODULES) TOP VIEW (NOT TO SCALE) BIPV SHINGLES (PV MODULES)SIDE VIEW (NOT TO SCALE) WIRE SCHEDULE REF QTY WIRE SIZE / TYPE QTY WIRE SIZE / TYPE CONDUIT NOTES KEY QTY 1 (2)AWG PV WIRE, USE-2 COPPER N/A (OR CODE APPROVED EQUIVALENT)A 30 57W 2 (2)AWG THWN-2 (POS, NEG)(1)AWG THWN-2 (GND)EMT (OR CODE APPROVED EQUIVALENT)B 2 3A (3)AWG THWN-2 (L1,L2,N)(1)AWG THWN-2 (GND)EMT (OR CODE APPROVED EQUIVALENT)C 1 3B D 1 200 A 3C E 4 F 5 G 6 H 7 I 8 J 9 K 1 GROUND No AC (V)240V RATED POWER MAX OUTPUT 10 L GROUND AC (V)RATED POWER MAX OUTPUT COM SHIELDED CAT6 LOW VOLT RATED FOR USE CU WIRE - LOW VOLT COMM WIRES M GROUND AC (V)RATED POWER MAX OUTPUT ENERGY SHINGLE PART NUMBER:GAF ENERGY TLS-2 ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV 0 Lydia Pearson KW (DC)KW (AC)DELTA M4-TL-US PV4 2026 Kemper Avenue GAF ENERGY TLS-2 ELECTRICAL DIAGRAM Santa Ana BY:Aldortega WATTAGE BUSBAR RATING 1.71 RAPID SHUTDOWN INVERTER 1 TBD 95138 #10 3/4in 3/4in #10 92705 #10 CA #10 #10 CA TBD COMPONENT 4000W 16.0A NOTES AND DETAILSMODELMAKE GAF ENERGY GAF ENERGY TLS-2 GPI00010105DELTA AC DISCONNECT 1 UTILITY METER MAIN PANEL TECHNICAL SPECS PV SHINGLE EXISTING EXISTING TBD TBDAC DISCONNECT 2 DELTA DELTA M4-TL-US 10/21/2025 (1) (30) INVERTER 2 INVERTER 3 GAF Energy LLC (CA) 973-628-3411 5981 Optical Ct 4 B #1062345 C-10 San Jose SEE THE FOLLOWING PAGE FOR THE ELECTRICAL DIAGRAM GENERAL NOTES string(s)of2 15 INV1 3A MAIN SERVICE PANEL (E)200 A BUSBAR (E)200 A MAIN BREAKER 200 A/2P(E)20 A/2P(N) Max. Ambient Temperature (degF):PV Module Power (W): DC System Summary INVERTER INV 1 INV 2 INV 3 MPPT - PV INPUT 1 2 3 4 1 2 3 4 1 2 3 4 CIRCUIT REFERENCE SINGLE STRING REFERENCES QTY OF MODULES IN SERIES STRING VMP (V) STRING VOC (V) STRING IMP (A) STRING ISC (A) COMBINED STRING IMP (A) COMBINED STRING ISC (A) ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV 0 Lydia Pearson GAF Energy LLC (CA)KW (DC)KW (AC)DELTA M4-TL-US PV5 2026 Kemper Avenue 5981 Optical Ct GAF ENERGY TLS-2 ELECTRICAL CALCS Santa Ana BY:Aldortega DELTA M4-TL-US (blank)(blank) A A1 , A2 13.26 6.63 116.14 15 12.60 6.30 172.48 10/21/2025 1.71 4 (1) 5787.8 B #1062345 C-10 95138 973-628-3411 CA 92705 San Jose CA (30) GROUNDING & GENERAL NOTES (CONT'D) 5.TRANSITION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - TRANSITION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 6.AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. 7.CONDUIT CARRYING THE DC WIRES ARE BONDED AT THE INVERTER. 8. INVERTERS ARE UL 1741 COMPLIANT. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH GROUNDING & GENERAL NOTES TIMBERLINE SOLAR USES BIPV SHINGLES (PV MODULES) THAT ATTACH DIRECTLY TO THE ROOF DECKING LIKE ORDINARY ASPHALT SHINGLES.THE BIPV SHINGLES HAVE NO METAL FRAME AND ARE NOT RACK MOUNTED.THE SYSTEM HAS NO EXPOSED, CONDUCTIVE METAL AND REQUIRES NO EQUIPMENT GROUND CONDUCTOR (EGC) FOR THE BIPV SHINGLES, WIRE COVERS OR TRANSITION BOX.THE EGC PATH BEGINS AT THE CONNECTION OF THE CONDUIT (EMT OR FMC, TYPICALLY) AT THE TRANSITION BOX OR PASS THROUGH DEVICE AND TERMINATES AT THE MAIN SERVICE PANEL. TIMBERLINE SOLAR AS A SYSTEM HAS BEEN LISTED TO MEET THE RAPID SHUTDOWN REQUIREMENTS OF ARTICLE 690.12 IN THE 2020, 2017 AND 2014 NEC (ANSI/NFPA 70). ANY LOSS OF CONNECTION TO THE UTILITY GRID WILL TRIGGER RAPID SHUTDOWN OF THE DELTA MCI AND/OR DELTA RSS PV RAPID SHUTDOWN EQUIPMENT (PVRSE) LISTED TO ANSI UL 1741 AND AS A PV HAZARD CONTROL SYSTEM (PVHCS) LISTED TO ANSI/CAN/UL 3741. 1.A SECOND FACILITY GROUNDING ELECTRODE IS NOT REQUIRED PER [NEC 690.47(C)(3)] 2.PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 3.DC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 4.ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. INTERCONNECTION NOTES 1. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9] & [NEC 230.95] 2. SUPPLY SIDE INTERCONNECTION ACCORDING TO[NEC 2014, 2017 -705.12(A), NEC 2020, 2023 -705.11] WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH [NEC 240.21(B)] ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV 0 KW (DC)KW (AC)DELTA M4-TL-US PV6 GAF ENERGY TLS-2 LABELS BY:Aldortega 10/21/2025 Lydia Pearson GAF Energy LLC (CA)1.71 (30)5981 Optical Ct2026 Kemper Avenue 973-628-3411 4 (1) B #1062345 C-10 San Jose CA 95138Santa Ana CA 92705 LABEL 1 AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED UNGROUNDED CONDUCTORS MAY BE EXPOSED DURING SERVICE. NEC. 690.35(F) LABEL 2 FOR PV DISCONNECTING MEANS WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION.NEC 690.17(E), NEC 705.22 LABEL 3 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS.NEC 690.54, NEC 690.13 (B) LABEL 4 AT POINT OF INTERCONNECTION FOR EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUTS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES, EACHSERVICE EQUIPMENT AND ALL ELECTRIC POWER PRODUCTION SOURCE LOCATIONS.NEC 705.12(D)(3 LABEL 6 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR.NEC 705.12(D)(2)(3)(B) LABEL 7 SIGN LOCATED AT UTILITY SERVICE EQUIPMENT.NEC 690.56(C) LABEL 8 SIGN LOCATED AT PV COMBINER PANEL. NEC 705.12(B)(2)(3)(C) 240 16 LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE (NFPA 70) 2017 National Electric Code 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] LABEL 5 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS.NEC 690.31(G)(3&4) LABEL 9 -INVERTER AT PV DISCONNECTING MEANS. TO BE USED IF NEC 2014 APPLIES. NEC 690.53 LABEL 10 -INVERTER 1 AT PV DISCONNECTING MEANS. TO BE USED IF NEC 2017 APPLIES. NEC 690.53 172.4 6.63 380 6.30 172.4 6.63 LABEL 12 SIGN LOCATED AT INVERTER RAPID SHUTDOWN SWITCH. NEC 690.56(C)(2) LABEL 11 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY NEC 690.56(C)(1). CEC 690.56(C)(1)(A) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM INVERTER ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV 0 KW (DC)KW (AC)DELTA M4-TL-US PV7 GAF ENERGY TLS-2 PLACARD BY:Aldortega CAUTION 2026 Kemper Avenue, Santa Ana CA 92705 (30)973-628-3411 5981 Optical Ct POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS SHOWN: Santa Ana CA 92705 10/21/2025 Lydia Pearson GAF Energy LLC (CA)1.71 2026 Kemper Avenue San Jose CA 95138 4 (1) B #1062345 C-10 M MSP INV INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH MAIN DISTRIBUTION UTILITY DISCONNECT PV ARRAY Solar Inverter for North America Single Phase Solar Inverter for North America M4-TL-US | M5-TL-US | M6-TL-US | M8-TL-US | M10-TL-US | M10-4-TL-US Key Features: x Smart inverter with BLE, optional WiFi, Ethernet, 3G / 4G cellular communication x Optional revenue grade meter (compliant with ANSI C12.20, Class 0.5) x Support bi-directional cloud communication x Support remote diagnosis and OTA x Type 4 protection x Built-in AFCI & Rapid shutdown controller x CEC efficiency 97.5% x UL 1741 SB, HECO compliant x CA Rule 21 Phase 1 & 2 & 3 compliant Solar Inverter for North America Rev 16.1 - 2/2022 © Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Model M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-US M10-4-TL-US INPUT (DC) Max. system voltage 600 V Nominal voltage 380 V Max. operating voltage 540 V Operating MPPT voltage range 50 V to 480 V Max. input current per MPPT 12 A 12 A 12 A 12 A 20 A 12 A Max. short circuit current per MPPT 15 A 15 A 15 A 15 A 30 A 15 A Max. DC/AC ratio 1)1.35 DC disconnect Integrated MPP tracker 2 2 3 3 2 4 Input strings available 2 - 2 2 - 2 2 - 2 - 2 2 - 2 - 2 2 - 2 2 - 2 - 2 - 2 OUTPUT (AC) Nominal output power @ 240Vac 3840 W 4800 W 5760 W 7680 W 9600 W 9600 W Max. output power @ 240Vac 4000 W 5000 W 6000 W 8000 W 10000 W 10000 W Nominal output power @ 208Vac 3328 W 4160 W 4992 W 6656 W 8320 W 8320 W Max. output power @ 208Vac 3648 W 4560 W 5472 W 7296 W 9120 W 9120 W AC operating voltage range 183 Vac to 228 Vac @ 208 Vac 211 Vac to 264 Vac @ 240 Vac Max. continuous current 16 A 20 A 24 A 32 A 40 A 40 A Nominal operating frequency 60 Hz Operating frequency range 59.3 Hz to 60.5 Hz Adjustable frequency range 50 Hz to 66 Hz Night consumption < 1.5 W 2) THD @ nominal power < 3 % Power factor @ nominal power > 0.99 Adjustable power factor range 0.85i to 0.85c GENERAL SPECIFICATION Max. efficiency 98% CEC efficiency 97.0 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.0 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.0 % @ 208 V 97.5 % @ 240 V Operating temperature range -22 °F to 149 °F (-30 °C to 65 °C) with derating above 113 °F (45 °C) Storage temperature range -40 °F to 185 °F (-40 °C to 85 °C) Humidity 0% to 95% Max. operating altitude 9,843 ft (3,000 m) Acoustic noise < 45 dB(A) @ 3 ft (1m) Solar Inverter for North America Rev 16.1 - 2/2022 © Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Model M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-US M10-4-TL-US MECHANICAL DESIGN Dimensions (W x H x D)16.7 x 23.2 x 5.9 in (425 x 590 x 150 mm) Display LED indicators Weight 3)41.9 lbs (19.0 kg) 41.9 lbs (19.0 kg) 44.3 lbs (20.1 kg) 45.2 lbs (20.5 kg) 47.6 lbs (21.6 kg) 47.6 lbs (21.6 kg) Cooling Natural convection Natural convection with internal fan DC connection Spring contact type AC connection Spring contact type Communication interface BLE, optional WiFi, Ethernet, 3G / 4G cellular communication Remote diagnose/monitoring Bi-direction via cloud Remote firmware update Via cloud (optional) Enclosure material Die-casting aluminum STANDARDS Enclosure protection rating Type 4 Safety UL 1741, CSA-C22.2 No. 107.1-16 Software approval UL 1998 Ground fault protection UL 1741 CRD Anti-islanding protection IEEE 1547-2018, IEEE 1547.1-2020 EMC FCC part 15 Class B AFCI UL 1699B (Type 1), NEC 2020 Article 690.11 Rapid shutdown protection NEC 2020 690.12 4) Rapid shutdown transmitter Optional pre-installed 5) Integrated meter ANSI C12.20, Class 0.5 Grid support regulation UL 1741 SB, California Rule 21 phase 1 & 2 & 3, HECO Compliant WARRANTY Standard warranty 10 years 1) Please refer to technical note for detailed string configuration 2) Without consumption of communication card 3) Without weight of revenue grade meter 4) Compliant with APS rapid shutdown system or Tigo rapid shutdown system. Compliant with Delta MCI or Delta Smart RSS as part of listed or field labeled PV Hazard Control System/PV Rapid Shutdown Array. 5) Optional pre-installed with APS rapid shutdown transmitter or Tigo rapid shutdown transmitter Delta Electronics (Americas), Ltd. 46101 Fremont Blvd, Fremont, CA 94538 Sales Email: Inverter.Sales@deltaww.com Support Email: Inverter.Support@deltaww.com Sales Hotline: +1-877-440-5851 or +1-626-369-8021 Support Hotline: +1-877-442-4832 Support (Intl.): +1-626-369-8019 Monday to Friday from 6am to 6pm PST (apart from Holidays) www.Delta-Americas.com Residential Energy Storage Solution for North America Rev 11 – 04/2022 © Copyright 2018 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Accessory: Rapid Shutdown System (RSS) Features: z With PLC, no additional wire needed for control z Comply with NEC 2020, Article 690.12* z String level rapid shutdown z Type 4 protection z Support rack mount or solar module mount z Support series connection up to 2 sub strings z With high voltage DC relay, high reliability RATINGS Model Name Smart RSS Delta part number GPI00010105 Maximum system voltage 600 Vdc Maximum current on controlled conductor 25 A dc @70ºC, 18.7 A dc @80ºC Rated input operating voltage 50 Vdc to 550 Vdc Rated input operating current 20 A @ 70 °C 15 A @ 80 °C Fuse Rating NA Self-power consumption <4 W GENERAL DATA Dimensions (W x H x D)6.0 x 7.9 x 2.1 in (152 x 201 x 53 mm) Weight 3.77 lbs (1.708 kg) Cooling Natural convection DC input/output connectors MC4 and H4 Enclosure material Die cast aluminum Operating temperature -40 °F to 176 °F (-40 °C to 80 °C) Humidity 0% to 95% Maximum operating altitude 9,843 ft (3,000 m) above sea level STANDARD COMPLIANCE Enclosure protection rating Type 4 Safety UL 1741, CSA C22.2 No. 330-17 Rapid shutdown NEC 2020 Article 690.12* EMC FCC Part 15 Class B *Installed with a listed or field labeled PV hazard control system a .i am 0%00 ona m ■ ff0%0. Timberline Solar" isn't a solar panel system. It's a comprehensive building -integrated photovoltaic roofing system that incorporates energy shingles and roofing shingles to generate solar energy from either new or replacement roofs. It complies with all applicable building codes and required safety standards. EN Timberline Solar ES 2 Nailable Energy Shingles Electrical Characteristics' Pm.. (±5/.) V (±5/.) Ise (±5%) 57 W 10.85 V 6.63 A Vma (±5%b) 9.04 V Imp (±5%) 6.30 A Max. System Voltage 1,000 V Max. Series Fuse 15 A Protection Class Class II Positive Load Rating 1,600 Pa Max. Modules in Series 48 Max. Parallel Strings 2 Cell Type Monocrystalline PERC Connector Type Staubli MC4: PV-KBT4/6X-UR, PV-KST4/6X-UR Connector Compatibility Staubli EV02: PV-KBT4-EVO 2A/6X, PV-KST4-EVO 2A/6X Temp. Coeff. I., +0.04%/°C Temp. Coeff. Vo. -0.26/./°C Temp. Coeff. P_ -0.35%/°C Mechanical Characteristics Energy Shingle Dimensions 68'A" x 161/8" x 1" (1,746 x 428 x 26 mm) Active Exposure 65" x 7.56" (1,651 x 192 mm) Energy Shingle Weight 10.1 lb. (4.58 kg) Energy Shingle Coverage Approximately 30 energy shingles per square (1.7 kW per square) Installed System Weight 3.36 Ib. /sq. ft. Allowed Roof Pitch 2:12 or greater Sheathing Minimums 7/16' OSB or 75/32" plywood Max. Installation Altitude 13,100 ff. (4,000 m) Avg. Ambient Temp. Range -40°F to 122°F (-40°C to 50°C) AMERICA C' V . W401 Intertek Applies to Timberline CCRR-0580 Approved for installation Solar ES 211 in High Velocity Hurricane Zones (HVHZ) per Florida Product ApprovalFL41599. 40 Meets requirements of the Texas Department of Insurance(TDI). Certifications ■ Fire Certification UL 790 Class A ■ Wind Classification ASTM D3161 Class F ■ Rapid Shutdown Article 690.12 NEC UL 3741 ■ Module Certifications' UL 61730-1, -2 SECT 30 UL 1703 ■ BIPV System Certification UL 7103 ■ Impact Resistance UL 2218 Class 1 ■ Model TLS-2, TLS-2AJM ■ ETL Listed PV Hazard Control System UL 3741 ■ Florida Product Approval FL41599 16 V" In. (428 mm) 7.56 in. (192 mm) 65 in. (1,651 mm) i I In. (26 mm) 65 "/a In. (1,746 mm) 65 In. (1,651 mm) 1 All electrical data shown under standard test conditions (STC) (1,000 W/mz, 25°C ±2°, 1.5 AM). 2 See installation manual for requirements to achieve a System Fire Class Rating with this product. I UL 61730-1 & UL 61730-2 superseded UL 1703 effective 12/4/19, CD w ENERGY Energy from o every roofs CITY OF SANTA ANA Planning and Building Agency Approved FOR PERMIT ISSUANCE Master ID: Date: Barun Corp I Design and Engineering I 610.202.4506 I chrisk@baruncorp.com I www.baruncorp.com February 11, 2023 GAF Energy 5981 Optical Court San Jose, CA 95138 ATTN: GAF Energy – Engineering Department Barun Corp – Structural Engineering Team has reviewed the Timberline Solar ES Tech Specs. Based on the information provided, the Timberline Solar ES product weighs 10 lbs per energy shingle. The shingle size is 17.125 in x 63.8 in. The weight of the product is therefore, 1.32 lbs/sq ft (psf). Provided that most residential roofs have a typical asphalt comp shingle roof with weight ranges between 2 psf and 4 psf per layer, it is my opinion that the installation of the Timberline Solar ES Product will meet the 2022 California Existing Building Code Section 502.4 captured below. 502.4 Existing Structural Elements Carrying Gravity Load Any existing gravity load-carrying structural element for which an addition and its related alterations cause an increase in design dead, live or snow load, including snow drift effects, of more than 5 percent shall be replaced or altered as needed to carry the gravity loads required by the California Building Code for new structures. Sample Calculation: Existing Condition New Condition Roofing (Asphalt Comp Shing) 1 Layer: 2.5 psf Underlayment: 0.5 psf Sheathing: 1.5 psf Framing (2x4 @ 24” O.C. assumed): 1.0 psf Miscellaneous: 1.5 psf Timberline Solar ES: 1.32 psf Underlayment: 0.5 psf Sheathing: 1.5 psf Framing (2x4 @ 24” O.C. assumed): 1.0 psf Miscellaneous: 1.5 psf Total Roof Dead Load: 7.0 psf Total Roof Dead Load: 5.82 psf Load Increase = 5.82 psf / 7.0 psf = 0.83% < 1.05%. Hence, compliant with 2022 CEBC 502.4 Please feel free to contact us with any questions or concerns. Prepared by: Structural Engineering Team