HomeMy WebLinkAbout1414 W Edinger Ave-REV 1 (Columns) - PlanDEMOLITION PLAN LEGEND EXISTING PARTITION TO BE DEMOLISHED EXISTING PARTITION TO REMAIN ACOUSTICAL CEILING SYSTEM TO BE DEMOLISHED EXISTING DOOR & FRAME TO BE DEMOLISHED EXISTING DOOR & FRAME TO REMAIN GYP. BOARD CEILING TO BE DEMOLISHED 1. DEMOLITION GENERAL NOTES APPLY TO ALL DEMOLITION SHEETS. 2. COORDINATE DEMOLITION AND PHASING EFFORTS WITH ARCHITECT AND OWNER'S REPRESENTATIVES. EVERY EFFORT SHALL BE MADE TO MINIMIZE DISRUPTION OF OWNER'S OPERATIONS AND TO PROVIDE BUILDING USER'S SAFETY. EXCESSIVE NOISE OR VIBRATION SHALL BE PRE-APPROVED AND COORDINATED WITH OWNER'S REPRESENTATIVE AND LANDLORD. 3. VERIFY EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS AND NOTIFY ARCHITECT OF DISCREPANCIES. 4. VERIFY AND MAINTAIN LOCATION OF EXISTING POWER, COMMUNICATION AND DATA CABLES TO PREVENT INTERRUPTION OF SERVICE. 5. COORDINATE DISRUPTION OF UTILITY SERVICES WITH OWNER, LANDLORD AND AS SPECIFIED. 6. EXISTING MATERIALS SHALL NOT BE REUSED UNLESS NOTED OTHERWISE OR AS AUTHORIZED BY ARCHITECT. 7. THE OWNER SHALL RESERVE THE RIGHT TO SALVAGE ANY MATERIALS. 8. PROVIDE PROTECTION FOR EXISTING BUILDING MATERIALS AND EQUIPMENT FROM DAMAGE DUE TO DEMOLITION OR CONSTRUCTION-RELATED INCIDENT PERFORMED UNDER THIS CONTRACT. 9. REPAIR OR REPLACE ITEMS DAMAGED AS A RESULT OF DEMOLITION OR CONSTRUCTION TO MATCH EXISTING FINISH AND /OR CONDITION. 10. CONSTRUCT TEMPORARY CONSTRUCTION PARTITIONS WITHIN EXISTING BUILDING WHICH OFFER A ONE-HOUR ENCLOSURE TO ISOLATE DEMOLITION AND CONSTRUCTION WORK FROM GENERAL PUBLIC AND AS DEEMED NECESSARY BY OWNER AND CODE OFFICIAL HAVING JURISDICTION. COORDINATE LOCATIONS WITH OWNER AND LANDLORD. MAINTAIN MEANS OF EGRESS THROUGHOUT THE WORK. 11. MAINTAIN A SECURE, DUST-PROOF, WEATHER-TIGHT ENCLOSURE. 12. WHERE PLASTER/STUD WALLS ARE INDICATED TO BE REMOVED; PREPARE ADJACENT WALLS TO RECEIVE NEW PATCH/FINISH BY SAWCUTTING ADJACENT PLASTER FINISH A MINIMUM OF 12 INCHES BEYOND DEMOLITION. 13. PATCH FLOOR, WALL AND CEILING PENETRATIONS RESULTING FROM REMOVAL OR REROUTING OF NEW OR EXISTING PIPING, DUCTWORK, CONDUIT, ETC. AS REQUIRED TO MAINTAIN FIRE SEPARATIONS. MATCH FINISH OF NEW OR EXISTING ADJACENT SURFACES 14. CAP DISCONNECTED MECHANICAL PIPING LINES WITHIN WALL OR FLOOR. PATCH AND FINISH AS REQUIRED TO MATCH NEW OR EXISTING ADJACENT SURFACES. 15. SEE MECHANICAL AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK. 16. SUITE HAS 2 EXISTING 200 AMP ELECTRICAL PANELS THAT CAN BE RELOCATED FOR NEW LAYOUT. 17. ON ROOF WHERE EQUIPMENT IS SITTING THERE IS EQUIPMENT ABANDONED AND A LOT OF DEBRIEF THAT NEED TO ME REMOVE AND HAUL AWAY, AND DO A POSSIBLE ROOF REPAIR AFTER REMOVAL. DEMOLITION PLAN NOTES DEMOLITION PLAN KEYNOTES ENRTY ENRTY W-2 W-2 W-4 W-1 202 202 203 201 201 204 204 ENRTY 202 205 206 207 207 204 209 209 210 W-1 210 A-3.02 8 12 13 211 211 1 1 WALL TYPES LEGEND NEW INTERIOR PARTITION METAL STUD WALL: • 5/8" GYP. BD. • 3-5/8" MIN. 25 GA. METAL STUD @ 16" O.C. & R-13 MIN. • SOUND ATTENUATION BATT INS. • 5/8" GYP. BD. • WALL HEIGHT: 11'-0" 1i 1i W-7 W-8 EXISTING STOREFRONT TO REMAIN1iW-1 1iW-9 EXISTING EXTERIOR CMU WALL TO REMAIN, TYP.1iW-2 EXISTING INTERIOR FURR WALL TO REMAIN, TYP.1iW-4 NEW INTERIOR PARTITION LOW METAL STUD WALL: • 5/8" GYP. BD. • 3-5/8" MIN. 25 GA. METAL STUD @ 16" O.C. • SOUND ATTENUATION BATT INS. PROVIDE LATERAL BRACING POST @4'-0" O.C. • 5/8" GYP. BD. • WALL HEIGHT: 7'-0" NEW INTERIOR PARTITION WET METAL STUD WALL: • 5/8" MOISTURE RESISTANT GYP. BD. • 6" MIN. 25 GA. METAL STUD @ 16" O.C. & R-13 MIN. • SOUND ATTENUATION BATT INS. • 5/8" MOISTURE RESISTANT GYP. BD. • WALL HEIGHT: 9'-0" THESE PLANS ARE FOR REVIEW ONLY AND NOT FOR CONSTRUCTION UNLESS THEY INCLUDE THE STAMP AND SIGNATURE OF ARCHITECT/ENGINEER AND THE APPROVAL OF THE APPROPRIATE GOVERNMENT AGENCY C-38176 MARC A. ABDELSAYED RENEWAL DATE LICENSED A RCHITECT STATE OF C ALIFORNIA 07/31/2025 Scale Date Drawn By Checked By Project Number REVISIONS JOB SITE: PLAN: PHONE: PLAN CHECK / JOB NO. 50 S De Lacey Ave. Unit #210 Pasadena, CA 91105 (760) 673-6837 (760) 673-2550 info@369architects.com As indicated 10 / 8 / 2 0 2 5 1 0 : 5 7 : 2 4 A M A-1.01 DEMO FLOOR PLAN 1414 W EDINGER AVE, SANTA ANA, CA 92704 CA N A M D E N T A L SA N T A A N A Checker J.F. 10/08/25 24001 1/4" = 1'-0" 1 EXISTING / DEMOLITION FLOOR PLAN 201 (E) EXTERIOR WALL W/STUCCO FINISH TO REMAIN. TYP. 202 (E) STOREFRONT GLASS SYSTEM TO REMAIN, TYP. 203 (E) STOREFRONT ENTRY DOOR TO REMAIN, TYP. 204 (E) FULL HEIGHT INT. PARTITION WALL TO BE DEMOLISHED. PREP AREA FOR (N) CONSTRUCTION, TYP. 205 (E) CONTRACTOR TO REVIEW W/ TENANT AND BUILDING OWNER ON (E) ITEMS TO BE REUSED SUCH AS DOORS, FRAMES, LIGHTING, SWITCHES, POWER RECEPTACLES, AND PHONE/DATA JACKS, ETC. 206 (E) GENERAL CONTRACTOR TO VERIFY IF ANY DEMOLISHED WALLS OR COLUMN FURRING CONTAIN MECHANICAL OR PLUMBING & ADVISE CLIENT & ARCHITECT. 207 (E) CEILING SYSTEM TO BE DEMOLISHED. 209 (E) REMOVE ALL TENANT SUPPLIED HVAC UNITS. 210 (E) DOOR AND FRAME TO BE DEMOLISHED. 211 (E) COLUMN TO REMAIN. REFER TO STRUCTURAL PLANS FOR MORE INFO. No. Description Date 1 REVISION 1 10/08/25 EXAM ROOM 136 EXAM ROOM 135 EXAM ROOM 134 LOUNGE 132 UTILITY 131 RECEPTION 125 WAITING AREA 120 PLAY AREA 121 TOILET 123 TOILET 124 OFFICE/IT 122 CORRIDOR 137 EXAM ROOM 133 LAB 126 COATS 138 EXAM ROOM 130 EXAM ROOM 129 EXAM ROOM 128 EXAM ROOM 127 16' - 2"0' - 5"13' - 11 1/4"0' - 5"23' - 5 1/4" 6' - 2 " 0' - 5 " 10 ' - 1 1 3 / 4 " 0' - 5 " 10 ' - 0 " 0' - 5 " 10 ' - 0 " 0' - 5 " 10 ' - 0 " 0' - 5 " 10 ' - 0 " 8' - 6 1/2"0' - 5"10' - 4"0' - 5"21' - 2"0' - 5"10' - 4 1/2" 16 ' - 0 " 0' - 5 " 26 ' - 4 3 / 4 " 0' - 5 " 16 ' - 0 " 59 ' - 2 3 / 4 " 59 ' - 2 3 / 4 " 51' - 8" TY P . EQ TY P . EQ 3' - 4 1/2" TYP. 4' - 2 1/2" 1' - 10" TYP. 5' - 4" 1' - 2 " 10 ' - 1 1 " 5' - 1 0 3 / 4 " 4' - 0 " TYP. 2' - 2" TYP. 5' - 4" TY P . 4' - 2 1 / 2 " TY P . 3' - 8 1 / 2 " 5' - 4 " 2' - 2 " TYP. 3' - 8 1/2" TYP. 4' - 2 1/2" 21' - 4" 15' - 0 3/4"14' - 0"3' - 3 1/4" 5' - 7 " 11 ' - 0 " 1' - 0 " 4' - 0 " 15 ' - 8 " 7' - 0"4' - 0" 7' - 7 " 8' - 0 " 6' - 8"6' - 8" 11' - 0"1' - 0"4' - 6"5' - 0 1/2" 2' - 9 " 3' - 4 " 16 ' - 1 3 / 4 " 4' - 7 " 16 ' - 5 " 11' - 7" 13' - 2"3' - 3 1/2" A-3.02 2 3 A-3.018 7 A-3.01 14 13 A-3.01 11 12 9 10 A-3.02 1 A-3.01 3 65 4 A-3.011 A-3.01 2 2' - 3 " 2' - 5 " 2' - 0 " 2' - 0 " W-9 W-8 W-7 W-7 FEC FE C FE C FEC W-2 W-2 W-4 308 302 315 318 301 315 318 308 301 306 317319 303 316 314 305305 313 307 304309 311 310 312 1 3 4 5 6 7 8 9 10 11 2 321 W-9 W-9 W-9 W-9 W-9 W-9 W-9 W-8 W-8 W-8 W-8 W-7 W-7 W-7 320 W-1 W-8 322 322 323 A-3.0115 W-7 W-7 G-07 12 G-07 12 A-3.02 6 7 4 5 DTL 8/G-06 DTL 8/G-06 48"30 " 324 324 1 1 WALL TYPES LEGEND NEW INTERIOR PARTITION METAL STUD WALL: • 5/8" GYP. BD. • 3-5/8" MIN. 25 GA. METAL STUD @ 16" O.C. & R-13 MIN. • SOUND ATTENUATION BATT INS. • 5/8" GYP. BD. • WALL HEIGHT: 11'-0" 1i 1i W-7 W-8 EXISTING STOREFRONT TO REMAIN1iW-1 1iW-9 EXISTING EXTERIOR CMU WALL TO REMAIN, TYP.1iW-2 EXISTING INTERIOR FURR WALL TO REMAIN, TYP.1iW-4 NEW INTERIOR PARTITION LOW METAL STUD WALL: • 5/8" GYP. BD. • 3-5/8" MIN. 25 GA. METAL STUD @ 16" O.C. • SOUND ATTENUATION BATT INS. PROVIDE LATERAL BRACING POST @4'-0" O.C. • 5/8" GYP. BD. • WALL HEIGHT: 7'-0" NEW INTERIOR PARTITION WET METAL STUD WALL: • 5/8" MOISTURE RESISTANT GYP. BD. • 6" MIN. 25 GA. METAL STUD @ 16" O.C. & R-13 MIN. • SOUND ATTENUATION BATT INS. • 5/8" MOISTURE RESISTANT GYP. BD. • WALL HEIGHT: 9'-0" 1. CONSTRUCTION NOTES APPLY TO ALL SHEETS. 2. ALL DIMENSIONS ARE ACTUAL AND ARE TO FACE OF GYP BD CLAD METAL STUD PARTITIONS OR CENTERLINE OF COLUMN, UNLESS NOTED OTHERWISE. 3. PROVISIONS SHALL BE MADE AT FULL HEIGHT NONBEARING WALLS FOR 2-INCH VERTICAL MOVEMENT OF BUILDING STRUCTURE WITHOUT TRANSFER OF COMPRESSIVE LOADS TO WALL. FILL IRREGULARITIES BETWEEN TOP OF WALL AND DECK ABOVE WITH FIRE SAFING INSULATION OR FIRE STOPPING MATERIALS AS REQUIRED TO MEET FIRE RATING OF RESPECTIVE WALLS. 4. GYPSUM BOARD AND PLASTER SURFACES SHALL BE ISOLATED WITH CONTROL JOINTS WERE INDICATED ON DRAWINGS AND/OR AS DESCRIBED IN THE SPECIFICATIONS. 5. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL 2" X 10" CONTINUOUS FIRE RETARDANT TREATED WOOD BLOCKING OR 10" WIDE METAL BACKING IN STEEL STUD PARTITIONS FOR PROPER ANCHORAGE OF WALL ATTACHED ITEMS INCLUDING BUT NOT LIMITED TO THE FOLLOWING: GRAB BARS, CASEWORK, MILLWORK, TOILET ACCESSORIES, TOILET PARTITIONS, WALL MOUNTED FIXTURES, MARKER BOARDS, TACK BOARDS, DOOR STOPS, AUDIO VISUAL BRACKETS, ETC. 6. SEE SHEET CP1.2 FOR LOCATION OF FIRE-RESISTANCE-RATED WALLS. WALLS OF FIRE- RESISTANCE-RATED CONSTRUCTION SHALL EXTEND TO UNDERSIDE OF FLOOR OR ROOF DECK ABOVE. 7. SEAL PENETRATIONS THROUGH FIRE-RESISTANCE-RATED CONSTRUCTION WITH THROUGH-PENETRATION FIRESTOP MATERIAL AS REQUIRED TO ACHIEVE RESPECTIVE FIRE-RESISTIVE RATING AND SMOKE STOPPAGE. 8. FIRE-RATED ENCLOSURES AROUND STEEL COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO UNDERSIDE OF FLOOR OR ROOF DECK ABOVE FOR EACH LEVEL. 9. INCLUDE OWNER-FURNISHED AND INSTALLED ITEMS AND OWNER FURNISHED AND CONTRACTOR INSTALLED ITEMS IN THE CONSTRUCTION SCHEDULE, AND COORDINATE WITH OWNER TO ACCOMMODATE THESE ITEMS. 10. EVERY AISLE SHALL BE NOT LESS THAN 36 INCHES WIDE IF SERVING ONLY ONE SIDE, AND LESS THAN 44 INCHES WIDE IF SERVING BOTH SIDES. 11. THE SURFACE OF FLOORS SHALL BE SLIP RESISTANT. WHEN TESTED IN ACCORDANCE WITH ASTM C1028B TEST PROCEDURE FOR COEFFICIENT OF FRICTION, TILE MUST ACHIEVE A WET AND DRY VALUE OF NOT LESS THAN 0.60. PRIOR TO THE INSTALLATION OF THE FLOOR COVERING. A WRITTEN STATEMENT FROM THE FLOORING MANUFACTURER MUST BE SUBMITTED TO THE BUILDING DIVISION, COMMUNITY DEVELOPMENT DEPARTMENT STATING THAT THE PRODUCT TO BE INSTALLED MEETS CURRENT INDUSTRY STANDARDS FOR SLIP RESISTANCE 12. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. LOCKS AND LATCHES IN BUILDINGS IN OCCUPANCY GROUP A HAVING AN OCCUPANT LOAD OF 300 OR LESS, GROUPS B, F, M, AND S, AND IN PLACES OF RELIGIOUS WORSHIP, THE MAIN EXTERIOR DOOR OR DOORS ARE PERMITTED TO BE EQUIPPED WITH KEY-OPERATED LOCKING DEVICES FROM THE EGRESS SIDE PROVIDE: A. THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS LOCKED, B. A READILY VISIBLE DURABLE SIGN IS POSTED ON EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. THE SIGN SHALL BE IN LETTERS 1 INCH (25 MM) HIGH ON A CONTRASTING BACKGROUND C. THE USE OF A KEY OPERATED DEVICE IS REVOCABLE BY THE BUILDING OFFICIAL FOR DUE CAUSE. CBC 1008.1.9.3 & 1008.1.9.4 13. FIRE BLOCKING MUST BE PROVIDED IN ACCORDANCE WITH SECTION 718.2 AT THE FOLLOWING LOCATIONS: a. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS. b. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT 10-FOOT INTERVALS ALONG THE LENGTH OF THE WALL. c. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE. CONSTRUCTION PLAN NOTES FLOOR PLAN KEYNOTES 1. NEW PLUMBING FIXTURES AND FITTINGS SHALL NOT EXCEED THE MAXIMUM ALLOWABLE FLOW RATES SPECIFIED IN SECTION 5.303.3. 2. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80 PSI, OR THE SHOWER SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN OPERATION AT A TIME. 3. CONSTRUCTION WASTE SHALL BE REDUCED BY 65% THRU A CITY OF LOS ANGELES CERTIFIED HAULER 4. NON-RESIDENTIAL ADDITIONS AND ALTERATIONS SHALL REQUIRE VERIFICATION THAT CALIFORNIA PROHIBITED UNIVERSAL WASTE MATERIALS ARE DISPOSED OF PROPERLY AND DIVERTED FROM LANDFILLS. (5.408.2) 5. A FINAL REPORT FOR THE TESTING AND ADJUSTING OF ALL NEW SYSTEMS SHALL BE COMPLETED PRIOR TO FINAL APPROVAL BY THE FIELD INSPECTOR. THIS REPORT SHALL BE SIGNED BY THE INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES.(5.410.4.4) 6. AN OPERATION & SYSTEMS MANUAL, SHALL BE PROVIDED TO THE OWNER OR REPRESENTATIVE AND TO THE FIELD INSPECTOR AT THE TIME OF FINAL INSPECTION. (5.410.4.5) 7. IF THE NEW HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MERV OF 8. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY. 8. ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT. 9. ARCHITECTURAL PAINTS AND COATINGS, ADHESIVES, CAULKS AND SEALANTS SHALL COMPLY WITH THE VOLATILE ORGANIC COMPOUND (VOC) LIMITS LISTED IN TABLES 5.504.4.1- 5.504.4.3. 10. THE VOC CONTENT VERIFICATION CHECKLIST, FORM GRN 2, SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURER’S SPECIFICATIONS SHOWING VOC CONTENT FOR ALL APPLICABLE PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION. 11. ALL NEW CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING: CARPET AND RUG INSTITUTE’S GREEN LABEL PLUS PROGRAM II. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH’S SPECIFICATION 01350 III. NSF/ANSI 140 AT THE GOLD LEVEL OR HIGHER IV. SCIENTIFIC CERTIFICATIONS SYSTEMS SUSTAINABLE CHOICE V. COMPLIANT WITH THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS CALIFORNIA (CA-CHPS) CRITERIA INTERPRETATION FOR EQ 7.0 AND 7.1 AND PC/GRN/CORR.LST.01 (REV. 2/2/2017) WWW.LADBS.ORG PAGE 5 OF 7 LISTED IN THE CHPS HIGH PERFORMANCE PRODUCT DATABASE. (5.504.4.4) 12. ALL NEW CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM. (5.504.4.4.1) 13. NEW HARDWOOD PLYWOOD, PARTICLE BOARD, AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD PRODUCTS USED IN THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE FORMALDEHYDE LIMITS LISTED IN TABLE 5.504.4.5. (5.504.4.5) 14. THE FORMALDEHYDE EMISSIONS VERIFICATION CHECKLIST, FORM GRN 3, SHALL BE COMPLETED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURER’S SPECIFICATIONS SHOWING FORMALDEHYDE CONTENT FOR ALL APPLICABLE WOOD PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION.” (5.504.4.5) 15. 80% OF THE TOTAL AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING: CERTIFIED AS A CHPS LOW-EMITTING MATERIAL IN THE CHPS HIGH PERFORMANCE PRODUCTS DATABASE II. CERTIFIED UNDER UL GREENGUARD GOLD III. CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOORSCORE PROGRAM IV. MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH’S SPECIFICATION 01350 (5.504.4.6) 16. AN AIR FILTER WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8 OR HIGHER SHALL BE INSTALLED IN THE MECHANICAL SYSTEM FOR OUTSIDE AND RETURN AIR PRIOR TO OCCUPANCY. (5.504.5.3) 17. MECHANICALLY VENTILATED BUILDINGS WITHIN 1,000 FEET OF A FREEWAY SHALL PROVIDE REGULARLY OCCUPIED AREAS OF THE BUILDING WITH A MERV 13 FILTER FOR OUTSIDE AND RETURN AIR. FILTERS SHALL BE INSTALLED PRIOR TO OCCUPANCY AND RECOMMENDATIONS FOR MAINTENANCE WITH FILTERS OF THE SAME VALUE SHALL BE INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL. (5.504.5.3) 18. ADDITIONS AND ALTERATIONS TO A BUILDING OR TENANT SPACE THAT MEET THE SCOPING PROVISIONS IN SECTION 301.3 FOR NONRESIDENTIAL ADDITIONS AND ALTERATIONS, SHALL REQUIRE VERIFICATION THAT UNIVERSAL WASTE ITEMS SUCH AS FLUORESCENT LAMPS AND BALLAST AND MERCURY CONTAINING THERMOSTATS AS WELL AS OTHER CALIFORNIA PROHIBITED UNIVERSAL WASTE MATERIALS ARE DISPOSED OF PROPERLY AND ARE DIVERTED FROM LANDFILLS. UNIVERSAL WASTE MEANS ANY OF THE FOLLOWING WASTES THAT ARE CONDITIONALLY EXEMPT FROM CLASSIFICATION AS HAZARDOUS WASTES PURSUANT TO SECTION 66261.9: (A) BATTERIES AS DESCRIBED IN SECTION 66273.2; (B) THERMOSTATS AS DESCRIBED IN SECTION 66273.4; (C) LAMPS AS DESCRIBED IN SECTION 66273.5; AND (D) CATHODE RAY TUBE MATERIALS AS DESCRIBED IN SECTION 66273.6. REFER TO CALIFORNIA UNIVERSAL WASTE RULE FINAL TEXT. GREEN BUILDING NOTES THESE PLANS ARE FOR REVIEW ONLY AND NOT FOR CONSTRUCTION UNLESS THEY INCLUDE THE STAMP AND SIGNATURE OF ARCHITECT/ENGINEER AND THE APPROVAL OF THE APPROPRIATE GOVERNMENT AGENCY C-38176 MARC A. ABDELSAYED RENEWAL DATE LICENSED A RCHITECT STATE OF C ALIFORNIA 07/31/2025 Scale Date Drawn By Checked By Project Number REVISIONS JOB SITE: PLAN: PHONE: PLAN CHECK / JOB NO. 50 S De Lacey Ave. Unit #210 Pasadena, CA 91105 (760) 673-6837 (760) 673-2550 info@369architects.com As indicated 10 / 8 / 2 0 2 5 1 0 : 5 7 : 2 4 A M A-2.01 PROPOSED FLOOR PLAN 1414 W EDINGER AVE, SANTA ANA, CA 92704 CA N A M D E N T A L SA N T A A N A Checker J.F. 10/08/25 24001 1/4" = 1'-0" 1 PROPOSED CONSTRUCTION PLAN 301 (N) INT. METAL STUD WALL PER WALL LEGEND, TYP. 302 (N) INT. DOOR PER SCHEDULE. PROVIDE COAT HOOK ON BACK OF DOOR OF ALL EXAMS, OFFICES, & RESTROOMS, TYP. 303 (N) 4'-0" TALL WINDOW. 1/4" TEMPERED GLAZING IN ALUMINUM FRAME. T/ FRAME TO MATCH INTERIOR DOOR FRAME HEIGHT. FRAME COLOR TO MATCH EXISTING STOREFRONT. 304 (E) STOREFRONT ENTRY DOOR TO REMAIN CLOSED. 305 (N) SINGLE COMP. ACCESSIBLE RESTROOM W/ UNISEX RESTROOM SIGNAGE. 306 SOLID HATCH DENOTES (N) MILLWORK AND/OR SOLID SURFACE COUNTERTOP AT 34" A.F.F. MAXIMUM, TYP. 307 EQUIPMENT/FURNITURE SHOWN FOR REFERENCE ONLY. FURNISHED AND INSTALLED BY TENANT. 308 (N) SEMI RECESSED FIRE EXTINGUISHER CABINET (POTTER ROEMER 7012-A FULL GLASS ). PAINT TO MATCH ADJ. WALL, TYP. 309 ACCESSIBLE TRANSACTION COUNTER AREA @ 30" A.F.F. WITH 36" MIN. CLEAR AREA. 310 SOLID SURFACE COUNTER TOP WORK SURFACE AT 30" A.F.F. 311 SOLID SURFACE TRANSACTION COUNTER AT 42" A.F.F. WITH PLASTIC LAMINATE WALL COVERING ON WAITING AREA SIDE OF KNEE WALL. 312 UPPER CABINETS 30" TALL WALL CABINETS. 313 PROVIDE FIRE TREATED WOOD BLOCKING FOR TV MOUNTING. TVS AND MOUNTING BRACKETS FURNISHED BY TENANT AND INSTALLED BY G.C. G.C. TO COORDINATE WITH ELECTRICAL AND LOW VOLTAGE CONTRACTORS. 314 PROVIDE 48"X96"X1/2" FIRE TREATED PLYWOOD FOR NETWORK, COMMUNICATION, AND A/V EQUIPMENT INSTALLATION. SECURE TO WALL AND PAINT TO MATCH OFFICE INTERIOR. 315 PROVIDE 52 1/2" WIDE X 50 1/2" HIGH ROUGH OPENING FOR X-RAY CABINET @ 42"A.F.F. VERIFY X-RAY EQUIPMENT ROUGH-IN AND INSTALLATION REQUIREMENTS WITH EQUIPMENT SUPPLIER. 316 SOLID SURFACE COUNTERTOP WITH BASE & WALL CABINETS. COUNTERTOP @ 34" A.F.F. T/WALL CABINETS. (AT LAB). 317 SOLID SURFACE COUNTERTOP WITH BASE & WALL CABINETS. COUNTERTOP @ 34" A.F.F. WALL CABINETS (AT BREAK ROOM). 318 DENTAL EQUIPMENT FURNISHED BY TENANT AND INSTALLED BY EQUIPMENT SUPPLIER. G.C. SHALL COORDINATE REQUIRED ROUGH-IN AND FINAL CONNECTIONS WITH ALL TRADES. 319 ROD & SHELF FURNISHED AND INSTALLED BY G.C. TOP OF SHELF INSTALLED AT 48" A.F.F. PROVIDE FIRE TREATED WOOD BLOCKING. 320 (N) REFILLABLE WATER JUG DISPENSER, PROVIDED BY TENANT. 321 VIDEO GAME CONSOLES FURNISHED BY TENANT AND INSTALLED BY G.C. G.C. TO COORDINATE FINAL CONNECTIONS WITH ELECTRICAL CONTRACTOR. 322 WALL TO BE OPEN ON TOP WITH 2'-0" WALL ENDS 323 INFILL THIS AREA WITH MATERIAL TO MATCH EXISTING CONSTRUCTION 324 (E) COLUMN TO REMAIN. REFER TO STRUCTURAL PLANS FOR MORE INFO. STUD SIZE STUD GAUGE STUD GAUGE 12" OC. 16" OC. 24" OC. 15' 14' 12'252 1/2" 19' 16' 14'253 5/8" 25' 20 21'206" RECOMMENDED MIN, SIZE CHART FOR NON-LOAD BEARING COMPOSITION STEEL STUD WALLS (2 LAYERS 5/8" THICK GYP. BD.) No. Description Date 1 REVISION 1 10/08/25 WATER CLOSET2 FIXTURESQTY. LIST OF NEW PLUMBING FIXTURES 2 8 3 1 8 2 1 LAVATORY SINK LOUNGE/LAB SINK MOP SINK CHAIRS FLOOR DRAIN FLOOR SINK S T R U C T U R A L N O T E SSTRUCTURAL ABBREVIATIONS S1.0 AL ENGINE R RNIA E OFESSI C77737G ISTERED CIVIL R STAT E PR ON O EXP. 6-30-27 E OF CALIF SIGNED: 10/07/25 R E V I S I O N REVISIONSMARKDATE SHEET OF 5 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 25-422 U.P./L.G. E.C.10-7-25 1 2 3 OW N E R : AN A H E I M L I N C O L N PR O P E R T I E S L L C AD D R E S S : 14 1 4 W E D I N G E R A V E , SA N T A A N A , C A 9 2 7 0 4 TE N A N T I M P R O V E M E N T AD D I T I O N & R E M O D E L PR O J E C T A D D R E S S : 14 1 4 W E D I N G E R A V E , SA N T A A N A , C A 9 2 7 0 4 14 1 2 E S P A N O L A V E . , MO N T E B E L L O , C A 9 0 6 4 0 WW W . E C A E N G I N E E R I N G . C O M IN F O @ E C A E N G I N E E R I N G . C O M P: 5 6 2 7 0 8 3 5 8 6 STRUCTURAL NOTES 1 8 DETAIL 4 DETAIL 3 DETAIL 2 DETAIL 1 DETAIL 8 DETAIL 7 DETAIL 6 DETAIL 5 DETAIL DETAIL DETAIL 9 DETAIL1112 AL ENGINE R RNIA E OFESSI C77737G ISTERED CIVIL R STAT E PR ON O EXP. 6-30-27 E OF CALIF SIGNED: 10/07/25 R E V I S I O N REVISIONSMARKDATE SHEET OF 5 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 25-422 U.P. E.C.Oct. 7, 25 1 2 3 OW N E R : AN A H E I M L I N C O L N PR O P E R T I E S L L C AD D R E S S : 14 1 4 W E D I N G E R A V E , SA N T A A N A , C A 9 2 7 0 4 TE N A N T I M P R O V E M E N T AD D I T I O N & R E M O D E L PR O J E C T A D D R E S S : 14 1 4 W E D I N G E R A V E , SA N T A A N A , C A 9 2 7 0 4 14 1 2 E S P A N O L A V E . , MO N T E B E L L O , C A 9 0 6 4 0 WW W . E C A E N G I N E E R I N G . C O M IN F O @ E C A E N G I N E E R I N G . C O M P: 5 6 2 7 0 8 3 5 8 6 TYPICAL DETAILS 2 S1.1 4 DETAIL 2 DETAIL 8 DETAIL 6 DETAIL 5 DETAIL DETAIL DETAIL 9 DETAIL1012 3 DETAIL 7 DETAIL DETAIL11 AL ENGINE R RNIA E OF ESSI C77737G ISTERED CIV IL R STAT E PR ON O EXP. 6-30-27 E OF CALIF SIGNED: 10/07/25 R E V I S I O N REVISIONSMARKDATE SHEET OF 5 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 25-422 U.P. E.C.Oct. 7, 25 1 2 3 OW N E R : AN A H E I M L I N C O L N PR O P E R T I E S L L C AD D R E S S : 14 1 4 W E D I N G E R A V E , SA N T A A N A , C A 9 2 7 0 4 TE N A N T I M P R O V E M E N T AD D I T I O N & R E M O D E L PR O J E C T A D D R E S S : 14 1 4 W E D I N G E R A V E , SA N T A A N A , C A 9 2 7 0 4 14 1 2 E S P A N O L A V E . , MO N T E B E L L O , C A 9 0 6 4 0 WW W . E C A E N G I N E E R I N G . C O M IN F O @ E C A E N G I N E E R I N G . C O M P: 5 6 2 7 0 8 3 5 8 6 TYPICAL DETAILS 3 S1.2 FOUNDATION PLAN scale: 1/4"=1'-0" PLAN NOTES LEGEND NOTE: CONTRACTOR IS RESPONSIBLE TO VERIFY ALL THE EXISTING CONDITION AND SHALL NOTIFY THE ENGINEER OF RECORD IF ANY DISCREPANCIES FOUND. AL ENGINE R RNIA E OF ESSI C77737G ISTERED CIVIL R STAT E PR ON O EXP. 6-30-27 E OF CALIF SIGNED: 10/07/25 R E V I S I O N REVISIONSMARKDATE SHEET OF 5 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 25-422 U.P. E.C.Oct. 7, 25 1 2 3 OW N E R : AN A H E I M L I N C O L N PR O P E R T I E S L L C AD D R E S S : 14 1 4 W E D I N G E R A V E , SA N T A A N A , C A 9 2 7 0 4 TE N A N T I M P R O V E M E N T AD D I T I O N & R E M O D E L PR O J E C T A D D R E S S : 14 1 4 W E D I N G E R A V E , SA N T A A N A , C A 9 2 7 0 4 14 1 2 E S P A N O L A V E . , MO N T E B E L L O , C A 9 0 6 4 0 WW W . E C A E N G I N E E R I N G . C O M IN F O @ E C A E N G I N E E R I N G . C O M P: 5 6 2 7 0 8 3 5 8 6 FOUNDATION PLAN 4 S2.0 ROOF FRAMING PLAN scale: 1/4"=1'-0" GENERAL CONTRACTOR NOTES ADDITIONAL NOTES PLAN NOTES LEGEND NOTE: CONTRACTOR IS RESPONSIBLE TO VERIFY ALL THE EXISTING CONDITION AND SHALL NOTIFY THE ENGINEER OF RECORD IF ANY DISCREPANCIES FOUND. C.J. ± ± ± ± AL ENGINE R RNIA E OF ESSI C77737G ISTERED CIVIL R STAT E PR ON O EXP. 6-30-27 E OF CALIF SIGNED: 10/07/25 R E V I S I O N REVISIONSMARKDATE SHEET OF 5 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 25-422 U.P. E.C.Oct. 7, 25 1 2 3 OW N E R : AN A H E I M L I N C O L N PR O P E R T I E S L L C AD D R E S S : 14 1 4 W E D I N G E R A V E , SA N T A A N A , C A 9 2 7 0 4 TE N A N T I M P R O V E M E N T AD D I T I O N & R E M O D E L PR O J E C T A D D R E S S : 14 1 4 W E D I N G E R A V E , SA N T A A N A , C A 9 2 7 0 4 14 1 2 E S P A N O L A V E . , MO N T E B E L L O , C A 9 0 6 4 0 WW W . E C A E N G I N E E R I N G . C O M IN F O @ E C A E N G I N E E R I N G . C O M P: 5 6 2 7 0 8 3 5 8 6 ROOF FRMG. PLAN 5 S2.1 EC + Associates Engineering www.ecaengineering.com 1412 Espanol Ave Montebello, CA 90640 P: 562 708 3586 STRUCTURAL CALCULATIONS FOR: NEW COLUMNS AND FOUNDATION FOR CANAM DENTAL PROJECT ADDRESS: 1414 W. EDINGER AVE. SANTA ANA, CA 92704 SIGNED: 10/7/2025 JOB NO.: 25-422__ JOB      ENGR.     EC JOB NO.     SHEET NO. DESIGN CRITERIA 1 Soil supporting footings is natural grade or engineered fill. 2 Soil allowable bearing pressure used in design_______________________________  3 Footing shall extend_____  minimum into undisturbed soil or_____ below finish grade whichever is lower.  4 All concrete shall develop a minimum compressive strength of 2500 psi in 28 days. 5 Reinforcing steel shall conform to ASTM 615, Grade 60. 6 Structural steel shall conform to the following: Wide flange shapes ASTM A992 TS shapes ASTM A500, Grade B Pipe shapes ASTM A53 , Grade B Other rolled shapes, Bars and plates ASTM A36 7 Structural steel shall be fabricated in a shop of an approved fabricator. 8 All welding shall be done by Certified Welders. 9 Concrete Block shall conform to ASTM C90, Grade N‐1. 10 Grout shall develop 2000 psi in 28 days. 11 Mortar shall be Type S and develop 1800 psi in 28 days. 12 All lumber shall be grade marked Douglas Fir. (Grading rule No. 17) Light Framing Construction Joist & Planks No. 2 Beams & Stringers No. 1 Posts & Timbers No. 1 13 Glue Laminated Timbers shall be combination No. 24F‐V8. 14 Plywood shall conform to PS 1‐95, Structural 1. 15 All material and workmanship shall conform to the requirements of 2022 California Building Code. ROOF LOADS roof rafter Roof lt wt tile (eaglelight)10.0 psf 10.0 psf 1/2" plywwod 1.5 psf 1.5 psf rafters 4.0 psf 4.0 psf insulation 0.5 psf Ceiling 3.0 psf beams/headers 1.0 psf MP&E/ misc.5.0 psf 1.0 psf D=25.0 psf 16.5 psf Lr=20.0 psf FLOOR LOADS flooring 1.0 psf 3/4" plywood 2.3 psf joist 3.0 psf ceiling 4.0 psf beams/headers 2.0 psf MP&E/ misc.2.7 psf D=15.0 psf L=40.0 psf EXTERIOR WALL LOADS 7/8" stucco 10.0 psf 1/2" plywood 1.5 psf 2x6 studs at 16"oc 1.5 psf insulation 0.5 psf 1/2" gyp board 2.3 psf MP&E/ misc.0.2 psf D=16.0 psf INTERIOR WALL LOADS 1/2" gyp board 2.3 psf 1/2" plywood 1.5 psf 2x6 studs at 16"oc 1.5 psf insulation 0.5 psf 1/2" gyp board 2.3 psf MP&E/ misc.1.9 psf D=10.0 psf ENGR.     EC DATE:SHEET NO. Fb Ft Fcperp.Fc Fv E E min CONSTRUCTION 1000 650 625 1650 180 1,500,000 550,000 NO. 2 900 575 625 1350 180 1,600,000 580,000 NO. 1 1200 825 625 1000 170 1,600,000 580,000 NO. 1 1350 675 625 925 170 1,600,000 580,000 COMBINATION 2400 1100 650 1650 265 1,800,000 930,000 NO. 24F‐V8 y‐dir 1450 1100 560 1650 230 1,600,000 830,000 (1)THE ABOVE VALUES ARE TAKEN FROM THE 2018 NDS. (2)USE STANDARD GRADING RULE NO. 17. DESIGNATION GRADE GLU‐LAM BEAMS THICKNESS 2" TO 4" THICK  2" TO 4' WIDE 2" TO 4" THICK 1/3/2023 15:35 DOUGLAS FIR‐LARCH  DESIGN VALUES 6" & WIDER 5x5 AND LARGER WIDTH NOT MORE  2" GREATER THAN THAN 2" GREATER THAN THICKNESS 5" & THICKER  BEAM & STRINGER LIGHT FRAMING JOIST & PLANKS WIDTH MORE THAN POST & TIMBER PROJECT: JOB NO. POST AREA ALLOWABLE LOAD (KIPS)-UNSUPPORTED HEIGHT IN FT (LOAD TABLE 100%) SIZE IN 2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2X4 5.25 1.00 2X4 X 5.25 4.58 3.61 2.87 2.32 1.91 1.60 1.35 1.16 1.00 2X4 5.25 1.05 2X4 X 5.25 4.67 3.72 2.98 2.42 2.00 1.67 1.42 1.22 1.05 2X6 8.25 1.66 2X6 X 8.25 10.49 9.66 8.68 7.65 6.67 5.79 5.04 4.40 3.86 3.41 3.03 2.71 2.43 2.19 1.99 1.81 1.66 2X8 10.88 2.18 2X8 X 10.88 14.3 13.9 13.3 12.5 11.7 10.7 9.8 8.8 7.96 7.17 6.46 5.84 5.29 4.81 4.39 4.01 3.68 3X4 8.75 4.57 3.46 2.70 2.15 1.76 3X4 X 8.75 7.78 6.20 4.97 4.04 3.33 2.79 2.36 2.03 1.76 3X6 13.75 7.14 5.42 4.23 3.38 2.76 3X6 X 13.75 17.5 16.1 14.5 12.8 11.1 9.7 8.39 7.33 6.43 5.68 5.05 4.51 4.05 3.66 3.31 3.02 2.76 3X8 18.13 9.35 7.11 5.56 4.45 3.63 3X8 X 18.13 23.9 23.1 22.1 20.9 19.4 17.9 16.3 14.7 13.3 11.9 10.8 9.7 8.82 8.01 7.31 6.68 6.13 4X4 12.25 10.9 8.68 6.96 5.66 4.67 3.90 3.31 2.84 2.46 4X6 19.25 16.8 13.5 10.9 8.85 7.31 6.12 5.19 4.46 3.86 4X6 X 19.25 24.5 22.5 20.3 17.9 15.6 13.5 11.7 10.3 9.01 7.96 7.07 6.31 5.67 5.12 4.64 4.23 3.86 4X8 25.38 21.8 17.6 14.2 11.6 9.6 8.04 6.83 5.86 5.08 4X8 X 25.38 33.5 32.4 30.9 29.2 27.2 25.0 22.8 20.6 18.6 16.7 15.1 13.6 12.3 11.2 10.2 9.4 8.59 6X6 30.25 27.6 26.3 24.8 23.0 20.9 18.8 16.8 15.0 13.3 11.9 10.7 9.59 8.66 7.84 7.13 6.51 5.97 6X8 41.25 37.6 35.9 33.8 31.3 28.5 25.7 22.9 20.4 18.2 16.2 14.6 13.1 11.8 10.7 9.7 8.9 8.1 6X8 X 41.25 39.3 38.5 37.5 36.2 34.7 33.0 31.0 28.9 26.8 24.6 22.6 20.7 18.9 17.4 15.9 14.7 13.5 6X10 52.25 44.4 42.7 40.4 37.7 34.7 31.5 28.3 25.4 22.7 20.3 18.2 16.4 14.8 13.5 12.3 11.2 10.3 6X10 X 52.25 47.2 46.7 46.2 45.5 44.7 43.8 42.8 41.5 40.2 38.6 37.0 35.2 33.3 31.5 29.6 27.8 26.1 8X8 56.25 53.8 52.8 51.5 50.0 48.1 45.9 43.4 40.7 37.9 35.0 32.3 29.6 27.2 25.0 23.0 21.2 19.6 X INDICATES BRACED IN WEAK DIRECTION ALL VALUES BASED ON DOUGLAS FIR-LARCH No . 1 GR A D E Co n s t No . 2 No . 2 No . 2 PROJECT: JOB NO. POST AREA ALLOWABLE LOAD (KIPS)-UNSUPPORTED HEIGHT IN FT (LOAD TABLE 125%) SIZE IN 2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2X4 5.25 1.01 2X4 X 5.25 4.83 3.73 2.94 2.36 1.93 1.61 1.36 1.17 1.01 2X4 5.25 1.06 2X4 X 5.25 4.97 3.87 3.06 2.47 2.03 1.69 1.43 1.23 1.06 2X6 8.25 1.67 2X6 X 8.25 12.40 11.08 9.64 8.26 7.06 6.04 5.20 4.51 3.94 3.47 3.07 2.74 2.46 2.21 2.01 1.82 1.67 2X8 10.88 2.19 2X8 X 10.88 17.5 16.7 15.7 14.5 13.2 11.9 10.6 9.4 8.37 7.47 6.69 6.01 5.42 4.91 4.46 4.07 3.73 3X4 8.75 4.67 3.51 2.72 2.17 1.77 3X4 X 8.75 8.28 6.45 5.11 4.12 3.38 2.82 2.39 2.04 1.77 3X6 13.75 7.32 5.50 4.27 3.41 2.78 3X6 X 13.75 20.7 18.5 16.1 13.8 11.8 10.1 8.67 7.52 6.57 5.78 5.12 4.57 4.09 3.69 3.34 3.04 2.78 3X8 18.13 9.60 7.24 5.62 4.49 3.66 3X8 X 18.13 29.2 27.9 26.2 24.2 22.0 19.8 17.6 15.7 14.0 12.4 11.1 10.0 9.03 8.18 7.44 6.79 6.22 4X4 12.25 11.6 9.03 7.15 5.76 4.73 3.95 3.34 2.86 2.48 4X6 19.25 18.0 14.1 11.2 9.03 7.42 6.19 5.24 4.49 3.89 4X6 X 19.25 28.9 25.8 22.5 19.3 16.5 14.1 12.1 10.5 9.20 8.09 7.17 6.39 5.73 5.17 4.68 4.26 3.89 4X8 25.38 23.5 18.4 14.7 11.9 9.8 8.15 6.90 5.91 5.12 4X8 X 25.38 40.9 39.0 36.7 33.9 30.8 27.7 24.7 21.9 19.5 17.4 15.6 14.0 12.6 11.5 10.4 9.5 8.71 6X6 30.25 33.4 31.4 28.8 26.0 23.1 20.3 17.8 15.7 13.9 12.3 10.9 9.80 8.81 7.97 7.23 6.59 6.03 6X8 41.25 45.6 42.8 39.3 35.4 31.5 27.7 24.3 21.4 18.9 16.7 14.9 13.4 12.0 10.9 9.9 9.0 8.2 6X8 X 41.25 48.5 47.1 45.4 43.3 40.8 38.0 35.0 32.0 29.1 26.4 23.9 21.7 19.7 18.0 16.4 15.0 13.8 6X10 52.25 54.0 51.1 47.4 43.1 38.6 34.3 30.3 26.7 23.7 21.0 18.8 16.8 15.1 13.7 12.4 11.3 10.4 6X10 X 52.25 58.6 57.8 56.9 55.9 54.6 53.0 51.2 49.2 46.9 44.5 41.9 39.3 36.8 34.3 31.9 29.7 27.6 8X8 56.25 66.4 64.7 62.6 60.0 56.8 53.3 49.4 45.4 41.5 37.8 34.4 31.2 28.5 26.0 23.8 21.8 20.0 X INDICATES BRACED IN WEAK DIRECTION ALL VALUES BASED ON DOUGLAS FIR-LARCH No . 1 GR A D E Co n s t No . 2 No . 2 No . 2 PROJECT: JOB NO. POST AREA ALLOWABLE LOAD (KIPS)-UNSUPPORTED HEIGHT IN FT (LOAD TABLE 160%) SIZE IN 2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2X4 5.25 1.01 2X4 X 5.25 5.03 3.83 2.99 2.39 1.95 1.63 1.37 1.17 1.01 2X4 5.25 1.07 2X4 X 5.25 5.22 3.99 3.13 2.51 2.05 1.71 1.44 1.23 1.07 2X6 8.25 1.68 2X6 X 8.25 14.56 12.48 10.49 8.78 7.37 6.24 5.34 4.61 4.01 3.52 3.11 2.77 2.48 2.23 2.02 1.84 1.68 2X8 10.88 2.21 2X8 X 10.88 21.6 20.2 18.5 16.6 14.7 12.9 11.3 9.9 8.71 7.71 6.87 6.14 5.53 4.99 4.53 4.13 3.78 3X4 8.75 4.76 3.56 2.75 2.19 1.78 3X4 X 8.75 8.70 6.66 5.22 4.18 3.42 2.85 2.40 2.06 1.78 3X6 13.75 7.46 5.58 4.31 3.43 2.79 3X6 X 13.75 24.3 20.8 17.5 14.6 12.3 10.4 8.90 7.68 6.68 5.86 5.18 4.61 4.13 3.72 3.37 3.06 2.79 3X8 18.13 9.81 7.34 5.68 4.52 3.68 3X8 X 18.13 36.1 33.7 30.8 27.6 24.4 21.4 18.8 16.5 14.5 12.9 11.4 10.2 9.21 8.32 7.55 6.88 6.29 4X4 12.25 12.2 9.32 7.30 5.85 4.79 3.99 3.37 2.88 2.49 4X6 19.25 19.0 14.6 11.4 9.18 7.51 6.25 5.28 4.52 3.91 4X6 X 19.25 34.0 29.1 24.5 20.5 17.2 14.6 12.5 10.7 9.36 8.21 7.26 6.46 5.78 5.21 4.71 4.28 3.91 4X8 25.38 24.8 19.1 15.0 12.1 9.9 8.23 6.96 5.95 5.15 4X8 X 25.38 50.5 47.2 43.2 38.7 34.2 30.0 26.3 23.1 20.3 18.0 16.0 14.3 12.9 11.6 10.6 9.6 8.81 6X6 30.25 40.7 37.2 33.1 28.9 25.0 21.6 18.7 16.3 14.3 12.6 11.2 9.97 8.95 8.07 7.31 6.66 6.08 6X8 41.25 55.6 50.7 45.1 39.4 34.1 29.4 25.5 22.2 19.5 17.2 15.2 13.6 12.2 11.0 10.0 9.1 8.3 6X8 X 41.25 60.7 58.3 55.3 51.6 47.5 43.1 38.8 34.7 31.1 27.8 25.0 22.5 20.3 18.5 16.8 15.3 14.1 6X10 52.25 66.2 61.0 54.9 48.4 42.2 36.6 31.9 27.8 24.4 21.6 19.2 17.1 15.4 13.9 12.6 11.5 10.5 6X10 X 52.25 74.3 73.0 71.4 69.5 67.2 64.5 61.3 57.9 54.2 50.5 46.7 43.1 39.8 36.6 33.8 31.2 28.8 8X8 56.25 83.3 80.3 76.5 72.0 66.7 61.0 55.2 49.7 44.7 40.1 36.1 32.6 29.5 26.8 24.4 22.3 20.4 X INDICATES BRACED IN WEAK DIRECTION ALL VALUES BASED ON DOUGLAS FIR-LARCH No . 1 GR A D E Co n s t No . 2 No . 2 No . 2 ROOF FRAMING PLAN Wood Beam LIC# : KW-06019792, Build:20.24.04.09 EC + Associates Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:R.R-1 Project File: 25-422 1414 W EDINGER AVE.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0250, Lr = 0.020 ksf, Tributary Width = 1.333 ft, (ROOF LOADS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.994: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 9.625 ft 49.28 psi= = 1,125.00 psi 2x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 2x12 Maximum Shear Stress Ratio 0.219 : 1 0.000 ft= = 1,118.03 psi Maximum Deflection 0 <360 332 Ratio =0 <180 Max Downward Transient Deflection 0.291 in 793 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.695 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 19.250 ft 1 0.802 0.177 0.90 1.000 1.001.00 1.00 1.71 649.7 810.0 0.32 162.01.00 28.61.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.250 ft 1 0.994 0.219 1.25 1.000 1.001.00 1.00 2.95 1,118.0 1,125.0 0.55 225.01.00 49.31.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.250 ft 1 0.890 0.196 1.25 1.000 1.001.00 1.00 2.64 1,000.9 1,125.0 0.50 225.01.00 44.11.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.250 ft 1 0.271 0.060 1.60 1.000 1.001.00 1.00 1.03 389.8 1,440.0 0.19 288.01.00 17.21.00 . Wood Beam LIC# : KW-06019792, Build:20.24.04.09 EC + Associates Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:R.R-1 Project File: 25-422 1414 W EDINGER AVE.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.6945 9.695 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.613 0.613 Max Upward from Load Combinations 0.613 0.613 Max Upward from Load Cases 0.356 0.356 D Only 0.356 0.356 +D+Lr 0.613 0.613 +D+0.750Lr 0.548 0.548 +0.60D 0.214 0.214 Lr Only 0.257 0.257 Wood Beam LIC# : KW-06019792, Build:20.24.04.09 EC + Associates Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RB2 WITH SISTER 2x12 RAFTERS Project File: 25-422 1414 W EDINGER AVE.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.2E 2,900.0 2,900.0 2,900.0 750.0 2,200.0 1,118.19 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0250, Lr = 0.020 ksf, Tributary Width = 0.6665 ft, (ROOF LOADS) Uniform Load : D = 0.0250, Lr = 0.020 ksf, Tributary Width = 2.250 ft, (ROOF LOADS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.171: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 9.625 ft 27.54 psi= = 3,651.06 psi 6.50 X 11.250Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 362.50 psi== Section used for this span 6.50 X 11.250 Maximum Shear Stress Ratio 0.076 : 1 0.000 ft= = 624.84 psi Maximum Deflection 0 <360 818 Ratio =0 <180 Max Downward Transient Deflection 0.107 in 2162 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.282 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 19.250 ft 1 0.148 0.066 0.90 1.007 1.001.00 1.00 4.44 388.4 2,628.8 0.83 261.01.00 17.11.00 1.00+D+Lr 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.250 ft 1 0.171 0.076 1.25 1.007 1.001.00 1.00 7.14 624.8 3,651.1 1.34 362.51.00 27.51.00 1.00+D+0.750Lr 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.250 ft 1 0.155 0.069 1.25 1.007 1.001.00 1.00 6.46 565.7 3,651.1 1.22 362.51.00 24.91.00 1.00+0.60D 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 19.250 ft 1 0.050 0.022 1.60 1.007 1.001.00 1.00 2.66 233.0 4,673.4 0.50 464.01.00 10.31.00 . Wood Beam LIC# : KW-06019792, Build:20.24.04.09 EC + Associates Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RB2 WITH SISTER 2x12 RAFTERS Project File: 25-422 1414 W EDINGER AVE.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.2823 9.695 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.483 1.483 Max Upward from Load Combinations 1.483 1.483 Max Upward from Load Cases 0.922 0.922 D Only 0.922 0.922 +D+Lr 1.483 1.483 +D+0.750Lr 1.343 1.343 +0.60D 0.553 0.553 Lr Only 0.561 0.561 Wood Beam LIC# : KW-06019792, Build:20.24.04.09 EC + Associates Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:R.R-1 OPPOSITE DIRECTION Project File: 25-422 1414 W EDINGER AVE.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0250, Lr = 0.020 ksf, Tributary Width = 1.333 ft, (ROOF LOADS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.054: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 2.250 ft 7.43 psi= = 1,125.00 psi 2x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 2x12 Maximum Shear Stress Ratio 0.033 : 1 3.564 ft= = 61.10 psi Maximum Deflection 0 <360 26036 Ratio =0 <180 Max Downward Transient Deflection 0 in 0 Ratio =<360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.002 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v n/a n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 4.50 ft 1 0.044 0.027 0.90 1.000 1.001.00 1.00 0.09 35.5 810.0 0.05 162.01.00 4.31.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 4.50 ft 1 0.054 0.033 1.25 1.000 1.001.00 1.00 0.16 61.1 1,125.0 0.08 225.01.00 7.41.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 4.50 ft 1 0.049 0.030 1.25 1.000 1.001.00 1.00 0.14 54.7 1,125.0 0.07 225.01.00 6.71.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 4.50 ft 1 0.015 0.009 1.60 1.000 1.001.00 1.00 0.06 21.3 1,440.0 0.03 288.01.00 2.61.00 . Wood Beam LIC# : KW-06019792, Build:20.24.04.09 EC + Associates Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:R.R-1 OPPOSITE DIRECTION Project File: 25-422 1414 W EDINGER AVE.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.0021 2.266 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.143 0.143 Max Upward from Load Combinations 0.143 0.143 Max Upward from Load Cases 0.083 0.083 D Only 0.083 0.083 +D+Lr 0.143 0.143 +D+0.750Lr 0.128 0.128 +0.60D 0.050 0.050 Lr Only 0.060 0.060 Wood Beam LIC# : KW-06019792, Build:20.24.04.09 EC + Associates Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RB1 Project File: 25-422 1414 W EDINGER AVE.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.2E 2,900.0 2,900.0 2,900.0 750.0 2,200.0 1,118.19 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Uniform Load : D = 0.0250, Lr = 0.020 ksf, Tributary Width = 1.333 ft, (ROOF LOADS) Load for Span Number 2 Point Load : D = 4.070, Lr = 4.470 k @ 4.250 ft, (EXISTING BEAM) Uniform Load : D = 0.0250, Lr = 0.020 ksf, Tributary Width = 1.333 ft, (ROOF LOADS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.552: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 9.833 ft 112.54 psi= = 3,651.06 psi 10.50 X 11.250Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 362.50 psi== Section used for this span 10.50 X 11.250 Maximum Shear Stress Ratio 0.310 : 1 9.833 ft= = 2,013.90 psi Maximum Deflection 1599 >=360 222 Ratio =848 >=180 Max Downward Transient Deflection 0.239 in 426 Ratio =>=360 Max Upward Transient Deflection -0.074 in Ratio = Max Downward Total Deflection 0.456 in Ratio =>=180 Max Upward Total Deflection -0.139 in fb: Actual F'b fv: Actual F'v Span: 2 : Lr Only Span: 1 : Lr Only Span: 2 : +D+Lr Span: 1 : +D+Lr .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 9.833 ft 1 0.370 0.209 0.90 1.007 1.001.00 1.00 17.93 971.6 2,628.8 4.30 261.01.00 54.61.00 1.00Length = 4.250 ft 2 0.370 0.209 0.90 1.007 1.001.00 1.00 17.93 971.6 2,628.8 4.30 261.01.00 54.61.00 1.00+D+Lr 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.833 ft 1 0.552 0.310 1.25 1.007 1.001.00 1.00 37.17 2,013.9 3,651.1 8.86 362.51.00 112.51.00 1.00Length = 4.250 ft 2 0.552 0.310 1.25 1.007 1.001.00 1.00 37.17 2,013.9 3,651.1 8.86 362.51.00 112.51.00 Wood Beam LIC# : KW-06019792, Build:20.24.04.09 EC + Associates Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION:RB1 Project File: 25-422 1414 W EDINGER AVE.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+D+0.750Lr 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.833 ft 1 0.480 0.271 1.25 1.007 1.001.00 1.00 32.36 1,753.3 3,651.1 7.72 362.51.00 98.11.00 1.00Length = 4.250 ft 2 0.480 0.271 1.25 1.007 1.001.00 1.00 32.36 1,753.3 3,651.1 7.72 362.51.00 98.11.00 1.00+0.60D 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.833 ft 1 0.125 0.071 1.60 1.007 1.001.00 1.00 10.76 582.9 4,673.4 2.58 464.01.00 32.81.00 1.00Length = 4.250 ft 2 0.125 0.071 1.60 1.007 1.001.00 1.00 10.76 582.9 4,673.4 2.58 464.01.00 32.81.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr10.0000 0.000 -0.1391 5.768 +D+Lr 2 0.4558 4.250 0.0000 5.768 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 13.209 Max Upward from Load Combinations 13.209 Max Upward from Load Cases 6.671 Max Downward from all Load Conditio -3.304 Max Downward from Load Combinations -3.304 Max Downward from Load Cases (Resis -1.825 D Only -1.478 6.538 +D+Lr -3.304 13.209 +D+0.750Lr -2.847 11.541 +0.60D -0.887 3.923 Lr Only -1.825 6.671 PROJECT: Bar #Area (in2) Soil Bearing Pressure:Miscellaneous:3 0.11 q =1500 psf column footprint =4 in 4 0.20 qu = q x 1.6 =2400 psf steel spacing factor =10 5 0.31 (for selection of steel spacing vs. size only) 6 0.44 Material Strengths:7 0.60 concrete =2500 psi Notes:8 0.78 fy =60 ksi Assumes Pu = 1.6 (DL + LL)9 1.00 10 1.23 11 1.56 Mark: Size Thick Pmax Depth Mu a As As As min As (ft) -SQ. (in) (k) (in)Vact (k)Vall (k)OK?Vact (k)Vall (k)OK? (k-in) (in) (Req'd)(200/Fy)(.0018) Use USE: 1.5 12 3.04 8 0.0 12.2 Y 2.7 65.3 Y 7 0.02 0.02 0.72 0.39 0.39 2 # 4 2.0 12 5.40 8 0.7 16.3 Y 6.5 65.3 Y 18 0.05 0.04 0.96 0.52 0.52 3 # 4 2.5 12 8.44 8 2.3 20.4 Y 11.3 65.3 Y 38 0.08 0.09 1.20 0.65 0.65 4 # 4 3.0 12 12.15 8 4.3 24.5 Y 17.3 65.3 Y 69 0.13 0.16 1.44 0.78 0.78 4 # 4 3.5 12 16.5 8 6.9 28.6 Y 24.3 65.3 Y 114 0.18 0.27 1.68 0.91 0.91 5 # 4 4.0 12 21.6 8 10.1 32.6 Y 32.4 65.3 Y 174 0.24 0.41 1.92 1.04 1.04 6 # 4 4.5 12 27.3 8 13.8 36.7 Y 41.6 65.3 Y 253 0.31 0.60 2.16 1.17 1.17 4 # 5 5.0 12 33.8 8 18.0 40.8 Y 51.8 65.3 Y 353 0.39 0.84 2.40 1.30 1.30 5 # 5 5.5 12 40.8 8 22.8 44.9 Y 63.2 65.3 Y 476 0.49 1.14 2.64 1.43 1.51 5 # 5 6.0 15 47.3 11 24.2 67.3 Y 72.3 112.2 Y 607 0.41 1.04 3.60 1.94 1.94 7 # 5 ONE WAY SHEAR: TWO WAY SHEAR: FOUNDATION PLAN JOB 6697 PALO VERDE PL ENGR. EC JOB NO. 25-257 SHEET NO. SPREAD FOOTINGS P1 =K P2 =K P3 =K P4 =K USE:TYPE 3.0 FOOTING P1 =K P2 =K P3 =K P4 =K USE:TYPE 3.0 FOOTING P1 =K P2 =K P3 =K P4 =K USE:TYPE 3.0 FOOTING P1 =K P2 =K P3 =K P4 =K P ALLOW.=K USE:TYPE 2.0 FOOTING P1 =K P2 =K P3 =K P4 =K P ALLOW.=K USE:TYPE 3.5 FOOTING 0 0 9.389 12.15 9.34 8.856 12.15 F1 9.389 0 0 F2 F3 0 12.15 0 0 0 0 9.34 8.856 F5 1.83 0 F4 1.48 3.31 5.4 0 16.538 6.54 6.67 0 013.21 FOUNDATION CALCS.