HomeMy WebLinkAbout10179203_3839 W. 1ST B-8 - Plan (2)Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www. santa-ana.orq ELECTRICAL SIGN REQUIREMENTS M*'ANg,t322.90&4#jgmj#Aft&#4979172**EVagEDBf#St#Yikagar,WT4Oke/J/RIA*wew#St yee,,SliT10%939,7.8 Code references are to the 2010 California Electrical Code (CEC) A. All signs require Planning Department approval. B. All electrical signs require electric plancheck and permit. 1. Manufacturer's instructions are required at the time of submittal. C-11: 3-21-2011 2. Submit detailed installation instructions including diagrams to the Building Department for plan review at the time of submittal. Plans must include appropriate items noted by this bulletin. 3. Cash or surety bond in the amount of $200.00 is required at time of issuance for each address. The cash or surety bond will be refunded after all.required finals. C. A building permit is also required - except for open or highlight neon lighting. \.D. Installation Requirements: CONTACT FIELD INSPECTOR PRIOR TO SIGN INSTALLATION. (SEE SECTION G OF THIS BULLETIN) 1. Conductors and equipment shall comply with California Electric Code Article 600. 2. All metal parts of a sign shall be bonded in tfie manner specified in Article 250. Isolated metal parts are permitted to be bonded by using an external green insulated conductor. Equipment grounding & bonding conductors must be sized by 110.26 and protected from physical damage. Minimum size is 14 AWG. CEC 600.7 3. A listed disconnect switch in the power supply primary, shall be installed within sight of sign or have permanently installed means for locking in an "OFF" position. This is also true for a transformer enclosure. CEC 600.6 4. A listed receptacle or an approved termination device shall be used for each neon electrode. To relieve stress at terminations, tubing shall be supported with listed tube supports in an approved manner within six inches of electrode connection. CEC 600.41 & 600.42 5. Every electric sign of any type shall be listed by an approved testing laboratory and shall be installed in conformance with this listing. That includes "1 of x", "2 of x" labeling for each separate unit of a multi-unit sign. CEC 600.3 6. All "can" letters and transformers housings shall have section labels that are readily visible after installation. CEC 600.4 7. Transformers shall be located where accessible and be securely fastened in place. Page 1 of 2 , When not inside the sign, they need a 3 foot high x 3 foot wide x 3 foot deep workspace. Transformers are permitted to be located in attics or canopies provided there is a passageway at least 3 feet high x 2 feet wide with a minimum 12 inch catwalk/walkway from the point of entry. Transformers must be securely fastened and independent of T- bar when above a suspended ceiling. No part of sign mav be fed with flexible cord when located above T-bar ceilings. CEC 600.21(E&F) & 400.8 8. Adequate illumination shall be provided for all working spaces about electrical equipment. This applies to attics and canopies when entry is required to service or inspect the equipment. At least one switch is required at entrance. CEC 110.34 & 600.21 9. Doorway to an attic or canopy space shall be minimum 3 feet by 2 feet wide. CEC 600.21(E) E. Open neon outline or highlight lighting. 1. To be treated as a sign by this department. However, Section D-5 & D-6 of this bulletin will not apply. 2. Neon tubing shall be located where not normally exposed to physical damage. Open neon tubing below 9 feet shall be protected from physical damage by an approved shielding method. CEC 600.30 and 1 10.34(E) F. Light-Emitting Diode (LED) Signs 1. Will be treated as a sign by this department. All sign rules in sections A, B, C, D, F, and G will apply as appropriate. 2. LED illumination for signage must be a listed or recognized component. Many LED manufacturers specify particular brands and models of transformers some do not. Manufacturer information to clarify this issue is required on LED sign plans. 3. Unlisted LEDs may not be used in an electrical sign or as permanently installed illumination. 110.3 4. Please have packaging or catalog cut-sheets on hand for inspector to review when LED modules do not bear listing symbols. G. Inspections 1. Contact an Electrical Inspector one (1) workday (minimum) in advance of installation to arrange a site meeting on dav of installation. 2. Call for inspection Monday through Friday, 8:00- 8:30 a.m. at (714) 647-5821. Approved prints and the job card must be on site for inspection. Page 2 of 2 November 14,2012 SIGN COMPONENTS MANUAL (SAM)120 5. When these products are used in applications other than signs or outline lighting, the need to conduct a temperature test shall be considered. SILICON CONSTELLATIONS INC 2980 SCOTT BLVD E324890 SANTA CLARA, CA 95054 LED Modules, Model No. REELLIOUS I. 1. These products are only suitable for connection to a Class 2 power source rated 30 Volt DC or less. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited circuit and which is rated greater than 30 V DC. 3. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 30 Volts DC or less. 5. These produds are not required to be endosed or protected from the weather in the end product. 6. These products may be secured in place in the end product by any means available. 7. When these products are used in applications other than signs or outline lighting, the need to conduct a temperature test shall be considered. SINO-OPTO USA LLC, DBA LED LIGHTING SERVICES LLC E342085 3575 COMMERCIAL AVE NORTHBROOK, IL 60062 LED Tube, Cat. Nos. LLIT8-48-18W, LLIT8-24-10W 1. These products are suitable for use in dry, or damp locations. 2. The lamp is maintained not less than 2 inches (50.8 mm) from combustible materials such as wood or plastic and parts that are a source of heat or arcing. Spacing from lampholder to sign housing is zero. 3. This LED lamp is not for use with internally shunted bipin lampholders used with fluorescent instant start lamps. SINO-OPTO USA LLC, DBA LED LIGHTING SERVICES LLC 3575 COMMERCIAL AVE E345360 NORTHBROOK, IL 60062 LED Tube, Cat. No. SN-T. 1. These products are suitable for use in dry, or damp locations. 2. The lamp is maintained not less than 2 inches (50.8 mm) from combustible materials such as wood or plastic and parts that are a source of heat or arcing. Spacing from lampholder to sign housing is zero. 3. This LED lamp is not for use with internally shunted bipin lampholders used with fluorescent instant start lamps. LED Tube, Cat. No. LLI-T10DBL. 1. Manufacturefs name, trade name, or trademark. 2. Distinctive catalog or model number. 3. The electrical ratings. 4. When multiple manufactures are involved, then a Factory ID identifying the product to a particular factory shall be provided. 5. Optional - "For Connection with Class 2 Circuits Only." SLOANLED, DIV OF SLOAN CO INC 5725 OLIVAS PARK DR E215393 VENTURA, CA 93003 LED Modules, Cat. Nos. 701261, 701261-PW, 701340, with suffix -R, -O,-Y, -B, -G, -W or -A; Cat. Nos. 701340-PW with suffix - R, -O, -Y, -A, -B, -G or-\N Cat. No. 701340-CM. 1.These products are only suitable for connection to a UL Listed or Recognized Class 2,24 V dc power source for Model 701340 and 7.5 V dc or 5 V dc power source for Model 701261. 2.These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies. 3.The total number of Model 701261 LED Lighting Units are not to exceed a total of 75 units per Class 2 drcuit. The total number of Model 701340 LED Lighting Units are not to exceed a total of 40 units per Class 2 circuit. 4.These products are suitable for use in dry, damp and wet locations. 5.These products are not required to be enclosed or protected from weather. Class 2 LEDs, 'ThinLED", Model 701228 , with suffix -A, -B, -G, -R, -W or -Y; Cat. No. 701228-18, with suffix -A, -B, -G, -R, -W or -Y. 1. These products are only suitable for connection to a UL Listed or Recognized Class 2, max. 12 V dc power source. Only Models 701228-A, -R, or -Y are only suitable for connection to UL Listed or. Recognized Class 2, max. 7.5 V dc. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies. 3. The total number of these products when interconnected is not to exceed a total of 14 feet or 14 "ThinLED" units per Class 2 circuit. These products are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations. 5. These products are not required to be enclosed or protected from weather. Class 2 power supply, Model LED Outline Lighting Systems "FlexiBRIGHT", Cat. No. 701499-X-Y, where X and Y may be any alphanumeric character. 1. These products are only suitable for connection to a UL Listed or Recognized Class 2,12 volt DC power source or less. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies. 121 SIGN COMPONENTS MANUAL (SAM)November 14,2012 3. These products are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply per Class 2 circuit. 4. These products are provided with wire soldered on the printed wiring board for connection. 5. These products are suitable for use in dry, damp and wet locations. Class 2 LEDs, Modules designated, "LED STRIPE2 (Border Light)" and "701956-XXXXXX" series, where XXXXXX may be replaced with alphanumeric characters. 1. These products are only suitable for connection to a UL Listed or Recognized Class 2, 15 Volt or less DC power source. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies. 3. Class 2 LEDs, "LED STRIPE2 (Border Light)", is rated max. 48 Watts per module. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations. Class 2 LED Module, Cat. No. 701269-00000000<x-MB Series, where x=0000= may be blank or any alphanumeric characters. 1. These products have been evaluated only for use when connected to the Class 2 output of a Listed or Recognized power source rated 15 V DC or less. 2. These products are suitable for use in dry, damp and wet locations with supply sources rated at 15V DC or less. 3. These products are not required to be endosed or protected from the weather in the end product. 4. These products may be secured in the end product with any available means. 5. These products are rated for a maximum of 7.5 watts or less per module. Class 2 LED Border Light, Class 2 "Border Light", Cat. No. 701189-XXXXXXXXXX series. 1. These products are only suitable for connection to a Class 2 power source, rated 30 Volt DC or less. 2. These produds have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limits and which is rated greater than 30 V DC. 3. These products are each rated max. 100 Watts per unit. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations when rated maximum 30 VDC. 5. These products are not required to be enclosed or protected from the weather in the end product when rated 30 VDC or less. 6. These products may be secured in place in the end product by any means available. 7. When these products are used in applications other than signs or outline lighting, the need to conduct a temperature test shall be considered. LED Strips, Cat. No. 701174, 701181 and 701195 with suffix -R, -Y, -A, -B, -W, or -G followed by -1" through -24". 1. These products are only suitable for connection to a UL Listed or Recognized Class 2,24 volt AC power source. 2. These produds have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies. 3. These products may be cut into segments through a black mark provided on the printed wiring board. No other cut across the board is permitted. 4. Cat. No. 701174 is rated for 4.2 watts per foot, Cat. No. 701181 is rated for 9.2 watts per foot and Cat. No. 701195 is rated at 1.5 Watts per foot. The total number of feet of each type and inches for the inch unit are not to produce a total wattage of greater than 60 watts per Class 2 circuit. 5. These produds are suitable for use in dry, damp and wet locations. 6. These products are not required to be enclosed or protected from weather. Class 2 LED Module, Cat. No. 701946-XXYYYYYYZZZ series, where XX, YYYYYY and ZZZ may be replaced with any alphanumeric characters or blank. 1. These products are suitable for use in dry, damp and wet locations and supplied only with a Class 2 power source rated 24 Volt DC or less. 2. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 3. These products are not required to be enclosed or protected from the weather in the end product. 4. These products may be secured in place in the end product by any means available. Class 2 power supply, Model 701285. 1. Power supply is intended to power LEDs in signs. 2. Power supply model is intended for permanent connection only. 3. These units are suitable for use in dry location without a need for an additional enclosure and in damp locations when installed inside a sign that complies with the Exclusion of Water Test in UL 48. 4. If the power supply output wiring is extended longer than the 5 foot leads provided, the spliced connections shall be made inside a Listed junction box suitable for the application included with proper grounding. Class 2 power supply, Cat. Nos. 701349, 701351. 1. Power supply models 701349 and 701351 are intended to power LEDs in signs. 2. Power supply model 701349 and 701351 are intended for permanent connection only. 3. These units are suitable for use in dry location without a need for an additional enclosure and in damp locations when installed inside a sign that complies with the Exclusion of Water Test in UL 48. 5. These power supplies have two outputs. The Class 2 output circuits are not to be conductively connected to each other in the sign by wiring or other type of component. 6. The maximum rated output power for Model 701349 is 42 watts at each Class 2 output. The maximum rated output power for Model 701351 is 60 watts at each Class 2 output. Class 2 power supplies, Models 701507-MOD, 701507-MOD277 (AD060S277/347-SLN). All may be followed by alphanumeric sumx. 1. These power supplies have a maximum of one Class 2 output. The output of these power supplies has been evaluated to Class 2 output requirements for dc circuits. 2. These products with Class 2 outputs are suitable for use in dry, damp and wet locations. 3. In the end product, power supply spacing to other heat producing components shall be minimum 4 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 4. When used in wet locations, each unit shall be provided with Listed (QCRV) 1/2 inch, liquid tight conduit fittings on primary circuit. November 14,2012 SIGN COMPONENTS MANUAL (SAM)122 5. When used in a cord connected product, the need for conducting a leakage current test shall be considered in the end product. 6. When not marked for Dry and Damp Locations Only the power supply primary bracket shall be provided with min. 3.5 threads and maximum 5 threads tapered for connection to liquid tight conduit fitting. If less than 3.5 threads, the liquid tight shall be provided with watertight fitting Listed (QCRV) 1/2 inch, liquid tight conduit fittings. 7. The suitability of grounding connection shall be determined in the end-use product. Class 2 power supply, Model 701680. 1. The product shall be installed in compliance with the mounting, spacing, casualty, and segregation requirements of the ultimate application. 2. These units are provided with a Class 105(A) insulation system. 3. The suitability of the input and output connections shall be determined in each end use application. 4. These power units are intended for dry or damp location use only. 5. Strain Relief on input lead construction and Impact Tests have not been investigated. 6. The polymeric enclosure of each unit has not been evaluated as ultimate enclosure. The flame class of polymeric enclosure of each unit is V-2, and the necessity of additional fire barriers shall be determined in end product. 7. Multiple power supplies shall be spaced at least 25mm (1 in.) end to end or 102mm (4 in.) in other directions. If lesser spacings are used, then the Temperature Test shall be conducted in the end use product. For reference the maximum enclosure (case) temperature on the power supply was 90°C when tested at 58.4° ambient. Class 2 power supply, Model 701680-MW. 1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 output. 2. The load powered by the Class 2 output of the power supplies rated at max 30 VDC or less are suitable for use in dry, damp and wet locations. 3. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 4. These products are provided with the following electrical ratings: 1 In.P.Mt_Output Model Vac | A Hz Vdc tA i701680-MW ]100-240 0.55 50/60 12 | 1.67 5. These products shall be enclosed in the end product. 6. These power supplies are suitable for use in dr'y and damp locations. Class 2 power supply, Model 701681. 1. The product shall be installed in compliance with the mounting, spacing, casualty, and segregation requirements of the ultimate application. 2. These units are provided with a Class 105(A) insulation system. 3. Input leads are Style 1015, No. 18 AWG, rated VW-1,600 V, 105°C. Output leads are Style 1430, No. 18 AWG, rated VW-1, 300 V, 105°C. The suitability of the input and output connections shall be determined in each end use application. 4. These power units are intended for dry or damp location use only. 5. Strain Relief and Impact Tests have not been investigated on input lead construction. The suitability of the endosure as ultimate enclosure shall be determined in the end-use application. 6. The polymeric enclosure of each unit has not been evaluated as ultimate enclosure. The flame class of the polymeric enclosure is V-0 and the necessity of additional fire barriers shall be determined in end product. 7. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. Class 2 power supplies, Model 701495. 1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of four Class 2 outputs. 2. These power supplies are only suitable for use in dry, damp and wet locations. 3. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. Class 2 power LED Lighting Strip, 701912-QQXXYYZZZ series, where QQ represents length, XX represents the LED color temperature, YY represents configuration and ZZZ represents the LED drive current. 1. These products are only suitable for connection to a Class 2 power source, rated 24VDC. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limits and which is rated greater than 24VDC. 3. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations with supply sources rated class 2. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. These products may be secured in place in the end product by any means available. 7. When these products are used in applications other than signs or outline lighting, the need to conduct a temperature test shall be considered. Class 2 "Dimming Control Knob" potentiometer, Model 701843. 1. These products are only suitable for connection to the output of a UL Listed or Recognized Class 2 power supply rated max 12 VDC. 2. These products are suitable for use in dry and damp locations. 3. These products are suitable for factory wiring only. 4. These products are 1 Kohm potentiometers intended for connection to max 12 VDC Class 2 power supply that drops the voltage to a 0-10 V signal to feed into the PWM dimmer. SPARTECH PLASTICS E202184 3454 N DETROIT ST WARSAW, IN 46580 Rigid sign enclosure systems, designated SunGard, Sungard Plus, PC-2000, DuraGard and PC-2000 Plus. 4' CHANNEL LETTER DETAIL See Figure On Page 2 For Mouting Method) --' #!· .-mig- · -igpgr=.f--ee:-6 -=- na--¥-7 "· r#.M.-10.-IM....„... .. . . The building sign will be installed with a IiII ("Cherry Picker)7tjPr.=31:C.... I • from the parking lot sp - TT SIGNS installer v - TT SIGNS inshller ..1, .Tr'ME&&112 Signis cente#edically &@#AnIly. zone I <P > PLANNER *hon¥Ay<40€2 DATE-lf@/13__ TRANSFERRED BY DATE PLANNING INSPECTION REQUiRED: ROUGH FINAL A NONE_ NAMENd@. )nap. (714) (#42 - 5300 24" G 9\\ 3\_,2-3 RETAIN PLANS FOR FUTURE RE..·':2:CES -- SUBJECT TO im:'33' CHECKED AND I . 31"IONS BELQW; O INTER,:OF· · «.',tv 6.1(4'N 3133 -81 O NO EXTE.'' O ALL UATEr C··· -1 (ER'·.ONS/MOL.··· i-iONS . f...i·.; fo i.r:..TCH EXIST:NG O SCREEN*C REQUIRED O SUBMIT LA,vDSCAPE PLANS tflf .Date: 6-18-2013 Prolect: T&K NAILS . UC.# 788515 RICHARD LE Address : 3839 W 1 St, Suite B.8 15103 Moran St TEL.714-373-4840 Santa Ana,CA 92703 Westminster . Ca 92683 FAX. 714-373-0360 Tel: CONDiTIONX Landlord's Ap Name:14 u, DDate: CC> tl !61 250 r.---- .05 Atuminum Channel Letters, FLUSH MOUNT TO WALL Ul Label Appropriate Non-Corrosive Mounting Hardware For Wall Material W Drain Holes In Letier Bottom 4 GB.core 115 VAC Power Supply esa or PS-2 Depending on Number of LED Modules} Mount In Dry Area Only. 3 Acryic Faces LED Lights -18 GA Wire From Power Supply To LED Connector Inside Each Letter. Four Supply Leads Per Powerpack. (Note: Length Of Each Lead Wire Must Be the Same To Each Set Of LED Ughts To Avoid Intensity ddlerences) -Metal Pass-Thru In Wall For Supply Leads -Electrical To Power Supply In Flexible Conduit Cut-Off Swilch To Be Visible From LED Power Supply. Bectrical To Box And Final Hook-up By G.C. 8ectrician. (120v-20 amp circuit) SECTION DETAIL - CHANNEL LETTERS - 5" DEEPALUMINUM CHANNEL LETTERS U.L LABLE. RETURN PAINT BRONZE COLOR - 3M" BRONZE TRIMCAPS - FONT LETTER: HELVETICA MEDIUM FONT - UL # E213701 -ACRYLIC 2793 RED - SLOAN LED LIGHT CONNECT 12 VOLT DC SLOAN POWER SUPPLY W/ DISCONNECT SWITCH - 1M DRAIN HOLE ENc,r EXCBE=D r'/12 - 4 TO 6 (3/16" X X SCREW) PER LETTER SITE PLAN - pl-.Ill.7 C NORTHGATE MARKET CVS PHARMACY =SHOPS "A". F 9mmro' r--b 0 111]Illuill liu lilli] 111 2 .974 057- #57- R 44 SHOPS T "B" Z Ii******1 19 1110 SHOPS tb mu '-; 1-- 1 // 1 LUALL FIRST STREET mil. J 6 4 4 N .... a *81001 ma j D . 29. Apollo Lighting System IP68* ChanneLED module medium to large face lit signs and IP68 • Uses the most energy efficient LEDs on the market today • Soft white color • Completely sealed module (IP68) • Run 56 ft. per 60W power supply · Constant Current Technology (CCT) • UL and cUL recognized, CE, CSA Certified · RoHS and WEEE compliant SPECIFICATIONS: Dimensions Lx Wx H 3 1/2in x 3/8in x 5/8in Modules per foot 2 Power per module .48W Viewing Angle 150° Maximum coverage per row Can depth Row coverage 4in to 5in 6in >5in 7in Operating temperature -40°C to +65°C Fastening Peel-n-stick and mechanical Packaging 25ft per tray, 5 trays per carton r . I - 1 - LUmens Item.Description · Part Number . - - - per foot - - J Apollo White (5000K)701269-W6-MB 96 Uses SloanLED 12 Volt DC Power Supply * IP68 - Ingress Protection Rating is a 2-digit numerical rating. This rating classifies the degrees of protection against dust, water, and impact that electrical equipment and enclosures can afford. 68 is the most stringent rating. Value-Line .B Economical solution · Classic performer · Run up to 75ft per 60W 12 VDC power supply · Constant Current Technology (CCT) · UL and cUL recognized, CE, CSA Certified • RoHS and WEEE compliant SPECIFICATIONS: Dimensions Lx Wx H Long 4in x 1/2in x 9/16in Short 2in x 1/2in x 9/16in Mini 11/8in x 7/16in x 1/2in Modules per foot Long 2 Short 3 Mini 4 Power per module White Long/Short .36W White Mini .27W Red Long/Short .6W Viewing Angle Whites 105° Reds 90° Maximum coverage per row by Color Can depth Row cow Red 5in 5in White 5in 4in Operating temperature -40°C to +70°C Fastening Peel-n-stick and mechanical Packaging 25ft per tray, 5 trays per carton Item 'i-21-1.- Paft , 7. ->(-1.- -1.umen Description 3 -r---' Nurtb?rh». - }_4 f < perfoi White Long (6800K)701269-WLX-MB 60 White Short (6800K)701269-WSX-MB 60 White Mini (6800K)701269-WTX-MB 60 Red Long 701269-RL-MB 22 Red Short 701269-RS-MB 22 Uses SloanLED 12 Volt DC Power Supply ... blul al,Tal ll l e, •,al fl.1 ard -2, ra 1 0, Ilal al I art SloanLED's 12 Volt DC Power Supplies The Sign Industry's Favorite Power Supply Modular 60-W Self Contained 20 1 P68 Rated i :2*im'- it. 47<' UL rated fo* · IP68 Rated (Ingress Protection 68) · IP68 is verified resistance to the intrusion of solids and water, even in harsh environments · Operating Temperatures -40° to 60° C • Auto-resetting · No fuses to replace or circuit breaker to reset. Short Circuit Protection automatically resets when short condition is corrected V · Small compact #ize • Operating Temveratures -40° to 60C nd damp locations · RoHS and;NEEE compliant · Modular design · Cluster with standard J-boxes to create multiple 60 Watt legs • UL, cUL, CSA, TUV, CE certification · UL certified for field retrofits · RoHS and WEEE compliant Quad 240 6 - • Built-in circuit protection fJRZUrr¢ntifvdliage and temperature • Operating Temperatures -40° to 60° C • UL recognition for dry, damp and wet locations SPECIFICATIONS for all SloanLED 12 Volt DC Power Supply Item Part # ·-Nominal Input input ' Power i Enclosure Spec :Overall -Dimensions Description Number f Voltage Current Output Dry> Damp Wet- 1.x Wx H Self Contained 20 701680 120-240 V 0.3 A 20 W X X 4.75in x 1.5 in x lin wiweigru2*9 NiNE[i#(MI*162 iED@109 11@8 @59 222 '080@011@D Modular 60-277 701507-MOD277 277-347 V 0.5 A 60 W X X X 10.5in x 2.5in€&65iru=;© Quad 240 (4 legs) 701495 120 V 3.0 A 240 W X X X 9.5irt x 5.9in#Br2j@ Power supplies carry required UL, cUL and CSA certification · Self Contained 20 and Modular 60 also carry CE certifica.:;a 7 Dimmer Solutions All SloanLED 12 Volt DC products can be dimmed using our dimming module (PN 701817) and either our manual Dim Control Box (PN 701843) or approved automatic controller. Fnstallation Cat)15SloanLED offers 18 gauge (PN '02490) and 14 gauge (PN 400301-100) to make yodtinstallation easier. i· al_ (7-1 rl- \-s 1 01 7 q€ 0-3420 652295- 3€5°\2 U \2* 6--g i , City of Santa Ana, CBC & CEC 2010C \62 < Minimum (4) screws per letter,maximum 24" on center, z nonatritinn ,#10 sheet metal screws, & holes per letter ' Ful n.-ul,u,•,- i /'.el (2) 194" drainr . I- 1 4 -'.t is.Q A local disconnect Mr the mon'ufnerit isign(s)required or the dedicated circuit-breaker(s) mus · 4 be individually lockable in th-6 off'bosjtion.9 : t - r. r95@,600-6to anypowar supply i;iattic prjboveAccessceiling shall be irrimbdiately frbki-aladder orth a 2 x3 fool access doot & passage with a1Anch walkway. ,CEC 600L21 (8)0) 11 6 1,City of Santa Ana Pihnning'&-Building Agency t 1 - - · . • I rt ..0 ELECTRICAL- .1 +1 It ;f ' PLAN APPROVAL .·'| drhis set of plans and specifications must be kept on the job at all times and It Is unlawful to make any .changes or alterations on same without wrltten.per- < mission from the Department of Building Safety- City ot Santa Ana. , - ..... PERMIT TYPE:<IE** ( MECH PERMIT#101 02(98 OCC. GROUP - CONSTR.TYPF CODE EDITION 20 11 FLOOD ZONE 1 1 ) ,. ' -The approval of this plan and speclficallons SHALLt NOT be held to permit nor be an approval of the , violation or any provisions of ANY City Ordinancei or State LaW.. Appr09*yll. 411/ iI .2 · CITY OF SANTA ANA - ;-. /1£- -' .DEPARTMENT OF BUILDING SAFETY 9 - FLOOD ZONE CERTIF. REQ'D YES . MICROFILM YES RADIANT BARRIER @ ROOF YES < - RESIDENTIAL DEV. FEE YES SCHOOL DISTRICT YES'i ..... t@@NE0kFULk,itch4£1.44-·tfu al-•.2... 6 1·9-•43 • 4-4 ·---4 »...r. l tlj\ 0 1-A ... P ,7