HomeMy WebLinkAbout1409 & 1411 W 7th - PlanE E E E E E E E E E E E E E E E E E W W W W W W W W W W W W W W W W W W W W W S S S S S S S S S S S S S S S S S S S W 7TH ST 4 (E) DRIVEWAY 7 LINE OF CURB PROPERTY LINE 50.00' PR O P E R T Y L I N E 1 4 0 . 8 7 5 ' PR O P E R T Y L I N E 1 4 0 . 8 7 5 ' PROPERTY LINE 50.00' (E) TO BE DEMO GARAGE 220 SF (E) ENTRY PORCH 2 (E) 6'H x 113.5' APPX. LONG BLOCK WALL 2 (E) 6'H x 113.5' APPX. LONG BLOCK WALL 8 7 8 P. U . E . 6' - 0 " 3 ' - 0 " 2 (E) 6'H x 49.5' APPX. LONG BLOCK WALL 6' SCE EASEMENT 32 ' - 5 1 / 2 " 13'-0" 5' - 5 1 / 2 " 12'-6" 28 ' - 2 1 / 2 " 9'-11 1/2" 18 ' - 6 " 12'-0" 12 ' - 2 1 / 2 " 7'-11" 12 ' - 0 " 22'-0" (E) 6'H x 50' APPX. LONG GATE 13 20 21 56 ' - 1 1 1 / 2 " SIDE WALK PUBLIC PARKWAY CENTER LINE OF STREET (E) WATER METER EA V E 1' - 0 " 1'-0" 1' - 0 " 11 1/2" 1' - 0 " 1'-0" 1' - 0 " 1' - 0 " 1'-0" 27 ' - 3 " 9 ' - 5 1 / 2 " 2 0 ' - 6 1 / 2 " 30 ' - 0 " 18 (E) BED 1 (E) BATH 1 (E) 4:12 SLOPE (E) MAIN HOUSE 1411 7TH ST. SANTA ANA, CA 92703 991 SF (E) KITCHEN (E) 4:12 SLOPE (E ) 4 : 1 2 SL O P E (E ) 4 : 1 2 SL O P E (E) 4:12 SLOPE (E ) 4 : 1 2 SL O P E (E) BED 2 (E) BATH 2 (E ) C L O S E T (E ) C L O S E T (E) HALL (E ) L A U N D R Y (E) OFFICE (E) LIVING (E) ELECTRIC 18 (N ) S T O R A G E 12'-4 1/2" 5'-8" 22'-0" 8'-4 1/2" 5'-8" 13'-0" 6'-5 1/2" 12'-6" 10'-0" 2'-4 1/2" 20 ' - 6 1 / 2 " 9 ' - 5 1 / 2 " 2 7 ' - 3 " 30 ' - 0 " W 7TH ST LINE OF CURB PROPERTY LINE 50.00' PR O P E R T Y L I N E 1 4 0 . 8 7 5 ' PR O P E R T Y L I N E 1 4 0 . 8 7 5 ' PROPERTY LINE 50.00' (E) ENTRY PORCH 2 (E) 6'H x 113.5' APPX. LONG BLOCK WALL 2 (E) 6'H x 113.5' APPX. LONG BLOCK WALL 8 2 (E) 6'H x 49.5' APPX. LONG BLOCK WALL 6' SCE EASEMENT (E) 6'H x 50' APPX. LONG GATE 13 20 SIDE WALK PUBLIC PARKWAY CENTER LINE OF STREET (E) WATER METER 4'-6 1/2" 20'-5 1/2" 25'-0" 49 ' - 8 " 40'-0" 23 ' - 6 " 6'-7 1/2" 12'-5 1/2" 5'-11" 24 ' - 1 " 2' - 1 " EAVE 1'-0" 1' - 0 " 1'-0" 1' - 0 " 1'-0" EA V E 1' - 0 " 1'-0" 32 ' - 5 1 / 2 " BLDG.SEP 8' - 5 ' ' . SIDE SB 6'-0''.1 1.1 7SIDE SB 4'-0''. 15 11 (N) BEDROOM 1 (N) BEDROOM 3 (N) CLOSEST (N) CLOSEST (N) BATH 1 (N) BATH 2 (N) BEDROOM 2 (N) LIVING 12 (N) DINING (N) KITCHEN (N) LAUNDRY (N) HOUSE ENTRY (N) 4:12 SLOPE (N) 4:12 SLOPE (N ) C L O S E S T EAVE PROJECTION. MATCH EXISTING ALL AROUND 1'-0" 1' - 0 " 1'-0" 1' - 0 " 1' - 0 " 1'-0" 1' - 0 " 1' - 0 " P. U . E . 6' - 0 " 3' - 0 " 10 A-07 1-HOUR FIRE- RESISTANCE-RATED 4.1 (N) DRIVEWAY (E) BED 1 (E) BATH 1 (E) 4:12 SLOPE (E) MAIN HOUSE 1411 7TH ST. SANTA ANA, CA 92703 991 SF (E) KITCHEN (E) 4:12 SLOPE (E ) 4 : 1 2 SL O P E (E ) 4 : 1 2 SL O P E (E) 4:12 SLOPE (E ) 4 : 1 2 SL O P E (E) BED 2 (E) BATH 2 (E ) C L O S E T (E ) C L O S E T (E) HALL (E ) L A U N D R Y (E) OFFICE (E) LIVING (E) ELECTRIC 18 (N) ADU 1409 7TH ST. SANTA ANA, CA 92703 990 SF (N) 504 SF MAIN HOUSE 2-CAR GARAGE (E) SEWER LATERAL V.I.F. 4" DIA. CLAY PIPE* *6 (E ) C L O S E T *5 FINISH GRADE AROUND THE STRUCTURE / ADDITION SHALL SLOPE AWAY FROM THE FOUNDATION A MINIMUM OF 5% FOR A MINIMUM DISTANCE OF 10 FEET. 2% SLOPE FROM AWAY FROM BUILDING (ALL AROUND) (N) 4:12 SLOPE (N) 4:12 SLOPE (N ) 4 : 1 2 SL O P E (N ) 4 : 1 2 SL O P E BEGIN CONSTRUCTION MEASUREMENT AT THIS CORNER 11" 1 A-08.1 1-HOUR FIRE- RESISTANCE-RATED 1 A-08.1 1-HOUR FIRE- RESISTANCE-RATED3 RE A R S E T B A C K 10 ' - 0 " (N) PORCH 26 SF 2 2' - 1 0 1 / 2 " 2' - 1 0 " 2' - 1 0 1 / 2 " 3'-0" 3'-0" 3 PROJECT CONTACT OWNERSHIP IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA A-01 TITLE SHEET / SITE PLANS / ROOF PLANS SI N G L E F A M I L Y R E S I D E N C E 14 1 1 7 T H S T . SA N T A A N A , C A 9 2 7 0 3 DETACHED ADU: 3 BEDROOMS, 2 BATHROOMS, LIVING, KITCHEN, DINING, AND LAUNDRY 11/05/2024 PLAN CHECK SUBMITTAL CINDY LY 12962 MAIN STREET GARDEN GROVE, CA 92840 PHONE: (657) 233-5233 EMAIL: CINDY@HAUSOFLINES.COM ALPHANRI LLC 12962 MAIN STREET GARDEN GROVE, CA 92840 PHONE: 657-233-5233 EMAIL: HELLO@PIGROUP.IO 8' SCALE : 3/32" = 1'-0" 0 16'24' THE PROPOSED PROJECT IS A 990 SF ONE-STORY DETACHED ACCESSORY DWELLING UNIT, 3 BEDROOMS, 2 BATHROOMS, LIVING, DINING, KITCHEN, AND LAUNDRY. DEMO EXISTING MAIN HOUSE GARAGE. STUCCO WALL TO MATCH EXISTING FOR DEMOLISHED DOOR. NEW PROPOSED 504 SF 2-CAR GARAGE FOR MAIN HOUSE. SOLAR SYSTEM ON SEPARATE PERMIT. SHEET INDEX VICINITY MAP PROJECT DATAGENERAL NOTES SCOPE OF WORK SITE PLAN NOTES 1. DEMOLITION CONTRACTOR SHALL RELOCATE REUSABLE MATERIALS TO DESIGNATED SALVAGE AREA, NON-USABLE MATERIALS SHALL BE PLACED APPROPRIATELY IN REFUSE BIN AND SHALL BE COVERED AT NIGHT AND DURING RELATIVE HIGH WINDS, RAIN, ETC...REFUSE BIN SHALL BE COVERED DURING TRANSFER TO AND FROM DUMP SITE. CONTRACTOR TO BE LIABLE FOR REFUSE SPILLING. ALL DEBRIS TO BE HAULED AWAY AND CLEAN-UP SHALL BE COMPLETED TO BROOM FINISH. EXISTING MATERIALS AND/OR STRUCTURE TO REMAIN SHALL BE PROTECTED FROM DUST, PAINT CHIPPING, ETC..., BY USE OF PLASTIC OR WHATEVER IS REQUIRED FOR PROPER PROTECTION. EXISTING STRUCTURES SHALL HAVE BRACING AND SHORING AS REQUIRED TO PROTECT THE EXISTING STRUCTURE. PROVIDE DE-WATERING FACILITIES FOR CONSTRUCTION AS REQUIRED. COORDINATE AS-BUILT INFORMATION, STRUCTURAL, ETC. TO DESIGNER/ENGINEER AS REQUIRED. 2. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. 3. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOTCLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL- BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES - WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 4. WHEN UTILITIES METER ALTERATION / RELOCATION OCCUR, INSTALLATION PROCEDURES SHALL BE VERIFIED AND APPROVED BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION. 5. NOTIFY AQMD FOR ASBESTOS REMOVAL PROCEDURE AND SUBMIT ASBESTOS REPORT TO BUILDING DIVISION PRIOR TO DEMOLITION PERMIT ISSUANCE. 6. MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF THIS PLAN REVIEW AND APPROVAL. MEP ARE SUBJECT TO BUILDING FIELD INSPECTION. 7. SETBACKS INDICATE REQUIRED MINIMUM DISTANCE FROM PROPERTY LINES. CONTRACTOR TO VERIFY ON SITE. 8.THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN “SFR SF” OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN “SFR SF” OF THE EXISTING RESIDENCE. 1) THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, ETC) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/ OR ADDITIONAL EXPENSES. 2) AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. 3) PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. 4) PROVIDE 72" HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE. 5) ALL CONSTRUCTION WASTE AND DEBRIS MUST BE CONTAINERIZED AT ALL TIMES 7) FINAL APPROVAL REQUIRED BY THE PUBLIC WORKS DEPARTMENT FOR STREET IMPROVEMENTS, CURB CORES, CURB/GUTTERS, ETC. SEPARATE PUBLIC WORKS PERMIT REQUIRED FOR DRIVEWAYS, APPROACH TO DRIVEWAY, SEWER LATERALS AND ANY WORK IN RIGHT OF WAY. 8) ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND AMENDMENTS. 9) A SURVEY SHALL BE PROVIDED BY A LICENSED SURVEYOR ON STRUCTURES WHICH DEFINE PROPERTY LINES, SET BACKS, DESIGNATED PARKLAND OR STREET RIGHT-OF-WAY. 10) DUST CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT. 11) WATER HEATER MUST BE STRAPPED TO WALL; SEE DETAIL ON SHEET A-07. 12) PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR WATER CONSUMPTION. 13) LAG BOLTS: PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR SMOOTH SHANK PORTION. 91 NDS 14) BLOCKING. ROOF RAFTERS AND CEILING JOINTS SHALL BE SUPPORTED LATERALLY TO PREVENT ROTATION & LATERAL DISPLACEMENT IN ACCORDANCE w/ THE PROVISIONS OF CH.8 & CH.6 15) CONTRACTOR AND/OR OWNER SHALL VERIFY CONSTRUCTION SITE TO CONFIRM THAT THERE IS NO TRACE OF DEMOLISHED SWIMMING POOL WITHIN 5 FT FROM PROPOSED PERIMETER OF THE CONSTRUCTION SITE. OTHERWISE, THEY NEED TO SUBMIT SOIL COMPACTION REPORT FROM LICENSED SOIL ENGINEER TO BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. 17) SHEAR WALLS, LATHING & PLASTER IN MATERIALS SHALL CONFORM TO THE STANDARDS LISTED IN CH.6 & CH.7 CRC 18) ALL BOLT HOLES SHALL BE DRILLED 1/32 TO 1/16" OVERSIZED." ENGINEER MUST INCLUDE IN STRUCTURAL OBSERVATION NOTES. 19) PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. 21) CONCRETE 3000 PSI 22) PARALLEL BEAM E.2.0 PSL 23) UFER GROUND IS REQUIRED AT NEW ELECTRICAL SERVICE. 24) UNDERGROUND UTILITIES REQUIRED ON SITE PLAN AND SHOW FOR ELECTRICAL, CABLE TV. AND TELEPHONE 25) ARC FAULT CIRCUIT INTERRUPTION PROTECTION IS REQUIRED FOR ALL BRANCH CIRCUITS PER 2022 CRC210.12 SHALL BE AFCI PROTECTED 26) BATHROOMS, KITCHEN, GARAGE & OUTSIDE OUTLETS WILL BE GFCI PROTECTED RECEPTACLE OUTLETS. 27) WATER SAVING WATER CLOSET w/ 1.28 GALLONS PER FLUSH. 28) PROVIDE MECHANICAL VENTILATION FOR BATHROOMS AND LAUNDRY ROOMS WITHOUT OPENABLE WINDOW. 29) GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24 INCH ARC OF A DOORWAY'S VERTICAL EDGE MUST COMPLY WITH CH. 3 CRC 30) LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. 31) EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDE AN AVERAGE ILLUMINATION OF 6 FEET-CADLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" ABOVE THE FLOOR LEVEL. 32) THE CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS, SURVEY THE PROPERTY AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND SCOPE OF WORK. ALL COST SUBMITTED SHALL BE BASED ON A THROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY DISCREPANCY AND/OR UNCERTAINTY AS TO WHAT MATERIALS OR PRODUCT IS TO BE USED SHOULD BE VERIFIED WITH THE OWNER OR ENGINEER OF RECORD. 33) DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE. 34) IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE OWNER AND THE DESIGNERS/ENGINEERS SHALL BE NOTIFIED, IN WRITING, IMMEDIATELY. A-01 TITLE SHEET / SITE PLANS / ROOF PLANS A-02 CALGREEN MANDATORY MEASURES A-03 CALGREEN MANDATORY MEASURES A-04 MAIN HOUSE (E) FLOOR PLAN & (E) ELEVATION A-04.1 MAIN HOUSE (N) FLOOR PLAN & (N) ELEVATION A-05 ADU FLOOR PLAN & ELECTRICAL/LIGHTING PLAN A-06 ADU ELEVATIONS & SECTIONS A-07 WALL AND ROOF DETAILS A-08 ARCHITECTURAL DETAILS A-08.1 ARCHITECTURAL DETAILS (CONT.) A-09 AGING-IN-PLACE / FALL PREVENTION NOTES & FEATURES / ELECTRIC-READY REQUIREMENTS D.01 SITE DRAINAGE PLAN S.0 GENERAL NOTES S1 FOUNDATION AND ROOF FRAMING PLAN SD1 STRUCTURAL DETAILS SD2 STRUCTURAL DETAILS T-24.1 RESIDENTIAL TITLE-24 T-24.2 RESIDENTIAL TITLE-24 PARKING REQUIREMENTS NOTWITHSTANDING ANY OTHER LAW, A LOCAL AGENCY, WHETHER OR NOT IT HAS ADOPTED AN ORDINANCE GOVERNING ACCESSORY DWELLING UNITS IN ACCORDANCE WITH SUBDIVISION, SHALL NOT IMPOSE PARKING STANDARDS FOR AN ACCESSORY DWELLING UNIT IN ANY OF THE FOLLOWING INSTANCES: THE ACCESSORY DWELLING UNIT IS LOCATED WITHIN ONE-HALF MILE WALKING DISTANCE OF PUBLIC TRANSIT.(BUSTOP # 6124) THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES: 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES APPLICABLE CODES SITE PLAN KEYNOTES LANDSCAPE LEGEND PV SYSTEM WILL BE UNDER A SEPARATE PERMIT THE MAIN ELECTRICAL SERVICE PANEL RATING OF 200 AMPS. THE MAIN SERVICE PANEL SHALL HAVE A MINIMUM BUSBAR A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR ELECTRIC INSTALLATION. THE RESERVED SPACE SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION AND SHALL BE PERMANENTLY MARKED AS "FOR FUTURE SOLAR ELECTRIC". SEPARATE PERMIT 1 (N) MAIN 2-METER ELEC PANEL 200A 2 (E) PERIMETER FENCE / BLOCK WALL 3 4 (E) DRIVEWAY 5 6 7 (E) LANDSCAPE 8 (E) TREE 9 (E) AC UNIT 10 11 12 SPACE FOR SOLAR PANEL INSTALLATION 13 (E) GATE 14 15 (N) AC UNIT INVERTER / METERING EQUIPMENT & PATHWAY FOR ROUTING FROM THE SOLAR ZONE TO THE MAIN SERVICE PANEL. (N) MAILBOX FOR ACCESSORY DWELLING UNIT ADJACENT TO MAIN HOUSE MAILBOX16 PROPOSED LOCATION OF THE NATURAL GAS METER TYPICALLY WITHIN FIVE FEET OF THE STRUCTURE’S FRONT WALL BUT NOT CLOSER THAN ONE FOOT FROM THE FRONT EDGE 17 (E) MAIN HOUSE ELEC. METER18 19 (E) WATER METER 20 1.1 (N) ADU SUB ELEC PANEL 100 AMP (N) MAIN HOUSE SUB ELEC PANEL 100 AMP SEE DETAIL 10/A.09 FOR 1-HR FIRE RESISTANT EAVE PROJECTION (N) WATER TANKLESS HEATER SEWER LINE FROM ADU ADU WATER POINT OF CONNECTION (E) ACCESSORY STRUCTURES NO LONGER ON SITE (GOOGLE MAP SHOWS OUTDATED CONDITION) 21 NEW (1) 24" BOX CANOPY TREE NEW (6) 5-GAL SHRUBS NEW (10) 1-GAL SHRUBS (E) GRASS NEW PERMEABLE HARDSCAPE STRUCTURE MATERIALS: EXTERIOR WALLS -WHITE STUCCO ROOF -GREY SHINGLES NOTE: ALL PLANT MATERIALS SELECTED FROM LA COASTAL GARDENS AND WWW.BEWATERWISE.COM ARE ACCEPTABLE DROUGHT TOLERANT PLANTS. LEGAL DESCRIPTION ASSESSORS PARCEL NO. APN: 405-074-30 FLOOD FEMA SHFA'S ZONE X LOT SIZE 7,100 SF ZONE R-1 RESIDENTIAL EXISTING STRUCTURE 991 SF NEW ADU 990 SF PORCH 26 SF NEW 2-CAR GARAGE 504 SF TOTAL 2,511 SF EXISTING: 991 SF (BUILDING FOOTPRINT) NEW: 990 SF, 504 SF 2-CAR GARAGE + 26 SF PORCH = 1520 SF (ADU LESS THAN 800 SF EXEMPT FROM LOT COVERAGE CALCULATION) LOT COVERAGE = 2,511 SF / 7,100 SF = 35.3% (LEGAL NON- COMPLIANCE) OCCUPANCY GROUP R-3/U CONSTRUCTION TYPE V-B AUTO. FIRE SPRINKLER MAIN HOUSE = NO; NUMBER OF STORIES MAIN HOUSE = 1; CALIFORNIA DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT THE CALIFORNIA DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT ISSUED AN ACCESSORY DWELLING UNIT HANDBOOK WITH UPDATES AND LAWS EFFECTIVE JANUARY 1, 2021(HTTPS://WWW.HCD.CA.GOV/POLICY-RESEARCH/DOCS/ADU_DECEMBER_2020 _HANDBOOK.PDF) "STATE ADU LAW DOES NOT ALLOW FOR THE LIMITATION ON THE NUMBER OF BEDROOMS OF AN ADU. A LIMIT ON THE NUMBER OF BEDROOMS COULD BE CONSTRUED AS A DISCRIMINATORY PRACTICE TOWARDS PROTECTED CLASSES, SUCH AS FAMILIAL STATUS, AND WOULD BE CONSIDERED A CONSTRAINT ON THE DEVELOPMENT OF ADUS." PROJECT DIRECTORY NE W A D U A D D R E S S 14 0 9 7 T H S T . SA N T A A N A , C A 9 2 7 0 3 3/32" = 1'-0"1EXISTING SITE PLAN / ROOF PLAN 4.1 (N) DRIVEWAY OWNERSHIP ALPHANRI LLC 12962 MAIN STREET GARDEN GROVE, CA 92840 PHONE: 657-233-5233 EMAIL: HELLO@PIGROUP.IO DESIGNER HAUS OF LINES 12962 MAIN STREET GARDEN GROVE, CA 92840 PHONE: (657) 233-5233 EMAIL: CINDY@HAUSOFLINES.COM ENGINEER MICHAEL MALCOLM PHILLIPS 14161 HAMMON PL WESTMINSTER, CA 92683 PHONE: (714) 213-1608 EMAIL: ONETRANG10@GMAIL.COM LICENSE: C-68338 TITLE 24 PM GROUP 7634 NANCY LN STANTON, CA 90680 PHONE: (174) 213-1608 • THE PROPERTY, MAIN DWELLING AND GARAGE SHALL BE SECURED WITHIN 24 HOURS FROM THE POSTING OF THE NOTICE AND ORDER TO ABTE A PUBLIC NUISANCE. • OBTAIN THE REQUIRED BUILDING PERMITS AND FINAL INSPECTIONS FOR THE BROKEN OR MISSING WINDOW REPAIR WORK. • REPAIR OR REPLACE ALL DETERIORATED OR DILAPIDATED EXTERIOR SURFACES, TO INCLUDE DAMAGE AND DRY ROTTED WOOD ON THE BUILDING EXTERIOR; BUT NOT LINITED TO SIDING, FASCIA BOARDS, EAVES, TRIM, WALLS, FLOORS, CEILINGS, DECKS, PORCHES, BALCONIES, GUARDRAILS AND HANDRAILS. SANTA ANA MUNICIPALCODE SECTION 8-1170/CA HEALTH AND SAFETY CODE SECTIONS 17920.3 (A-O); (A) (14); (E); (J) AND (K). SAMC 8-2000/INTERNATIONAL PROPERTY MAINTENANCE CODE SECTIONS 304.1,304.1.1,304.2. • REPLACE ALL BROKEN WINDOWS, WINDOW FRAMES AND GLAZING IN COMPLIANCE WITH CA BUILDING CODES AND CA HEALTH & SAFETY CODE STANDARDS. • OBTAIN PERMITS FOR ALL WINDOW CHANGE OUTS INSTALLED WITHOUT THE BENEFIT OF A BUILDING PERMIT. SAMC 8-2000/INTERNATIONAL PROPERTY MAINTENANCE SECTION CODE(S) 304.13,304.13.1, 304.13.2 AND 304.14. SAMC 8-43 AND 8-94/CA BUILDING CODE SECTION 105.1 (PERMIT REQUIRED) AND CA BUILDING CODE SECTION 1103.12 (FINAL INSPECTION REQUIRED). • REPAIR OR REPLACE ALL EXTERIOR SURFACES IN DISREPAIR AND PROVIDE PROPER WEATHER PROTECTION IN COMPLIANCE WITH INTERNATIONAL PROPERTY MAINTENANCE CODE STANDARDS. SAMC 8-2000/INTERNATIONAL PROPERTY MAINTENANCE SECTION CODE 304.2. • REPAIR OR REPLACE DETERIORATED OR DILAPIDATED PERIMETER FENCING. SAMC SECTION 8-1951(C)/SAMC 8-1170 AND CA HEALTH & SAFETY CODE SECTION (A) (14) & (C). ADDITIONAL AUTHORITY: MONITORING PROGRAM IS REQUIRED IN COMPLIANCE WITH SAMC SECTION 8-1988. A. ANY REGISTRABLE PROPERTY SHALL BE MAINTAINED IN COMPLIANCE WITH THE REQUIREMENTS OF THIS CHAPTER AND CODE CHAPTERS 16, CHAPTER 41, THE UNIFORM CODE FOR THE ABATEMENT OF DANGEROUS BUILDINGS, INTERNATIONAL PROPERTY MAINTENANCE CODE AND CALIFORNIA HEALTH AND SAFETY CODE SECTION 17920.3. B. REGISTRABLE PROPERTY SHALL BE KEPT FREE OF WEEDS, DRY BRUSH, DEAD VEGETATION, EXCESSIVE FOLIAGE GROWTH, TRASH, JUNK, DEBRIS, BUILDING MATERIALS, ANY ACCUMULATION OF NEWSPAPER, CIRCULAR FLYERS, NOTICES (EXCEPT THOSE REQUIRED BY FEDERAL, STATE OR LOCAL LAW), DISCARDED PERSONAL ITEMS INCLUDING, BUT NOT LIMITED TO, FURNITURE, CLOTHING, LARGE AND SMALL APPLIANCES, PRINTED MATERIAL OR ANY OTHER ITEMS THAT GIVE THE APPEARANCE THAT THE PROPERTY IS ABANDONED, C. REGISTRABLE PROPERTY SHALL BE MAINTAINED FREE OF GRAFFITI, TAGGING OR SIMILAR MARKING IN ACCORDANCE WITH ARTICLE IV OF CHAPTER 10 OF THIS CODE. ANY REMOVAL OR PAINTING OVER OF GRAFFITI SHALL BE WITH AN EXTERIOR GRADE PAINT THAT MATCHES THE COLOR OF THE EXTERIOR OF THE STRUCTURE. D. VISIBLE YARDS SHALL BE LANDSCAPED AND CONTINUOUSLY MAINTAINED BY PROPER PRUNING, MOWING OF LAWNS, WEEDING, REMOVAL OF LITTER, FERTILIZING, REPLACEMENT OF PLANTS AND DECORATIVE MATERIALS WHEN NECESSARY, AND THE REGULAR WATERING OF PLANTS. LANDSCAPING INCLUDES, BUT IS NOT LIMITED TO, GRASS, GROUND COVERS, BUSHES, SHRUBS, HEDGES OR SIMILAR PLANTINGS, DECORATIVE ROCK OR BARK OR ARTIFICIAL TURF/SOD DESIGNED SPECIFICALLY FOR RESIDENTIAL INSTALLATION AND STANDARDS LISTED IN SECTION 41-609 "LANDSCAPE," AND ABIDE BY THE PLANNING AND PUBLIC WORKS DIVISION LANDSCAPE STANDARDS. LANDSCAPING DOES NOT INCLUDE WEEDS, GRAVEL, BROKEN CONCRETE, ASPHALT, PLASTIC SHEETING, MULCH, INDOOR-OUTDOOR CARPET OR ANY SIMILAR MATERIAL. E. POOLS AND SPAS SHALL BE KEPT IN WORKING ORDER SO THAT WATER REMAINS CLEAR AND FREE OF POLLUTANTS, MOSQUITO LARVAE, AND DEBRIS, OR ALTERNATIVELY SHALL BE DRAINED AND KEPT DRY. HI EITHER CASE, PROPERTIES WITH POOLS AND/OR SPAS MUST COMPLY WITH THE MINIMUM SECURITY FENCING REQUIREMENTS SET FORTH IN ARTICLE XIII OF THIS CHAPTER AND MINIMUM STATE STANDARDS, WHICHEVER IS MORE RESTRICTIVE. NOTICE & ORDER TO REPAIR SUBSTANDARD BUILDING AND ABATE PUBLIC NUISANCE: F. ADHERENCE TO THIS SECTION DOES NOT RELIEVE THE BENEFICIARY/TRUSTEE OR PROPERTY OWNER OF OBLIGATIONS SET FORTH IN ANY COVENANTS, CONDITIONS AND RESTRICTIONS AND/OR HOMEOWNER'S ASSOCIATION RULES AND REGULATIONS WHICH MAY APPLY TO THE PROPERTY. G. AN ENFORCEMENT OFFICIAL MAY ALLOW EXCEPTIONS TO THE MAINTENANCE STANDARDS SET FORTH IN THIS SECTION FOR REGISTRABLE PROPERTY THAT HAS SUBMITTED A DEVELOPMENT APPLICATION WITH THE CITY AND IS UNDERGOING THE APPROVAL PROCESS OR IS UNDER CONSTRUCTION AND/OR REPAIR, THAT IS DILIGENTLY PURSUED FOR AT LEAST THREE (3) BUSINESS DAYS PER WEEK, AND IS UNDERTAKEN IN COMPLIANCE WITH ALL APPLICABLE LAWS INCLUDING, BUT NOT LIMITED TO, CITY PERMITTING REQUIREMENTS H. THE BUILDING IS THE SUBJECT OF AN ACTIVE BUILDING PERMIT FOR REPAIR OR REHABILITATION AND THE OWNER IS PROGRESSING DILIGENTLY TO COMPLETE THE REPAIR OR REHABILITATION; THE BUILDING MEETS ALL APPLICABLE CODES, IS ACTIVELY MAINTAINED IN ACCORDANCE WITH ALL CITY ORDINANCES, IS READY FOR OCCUPANCY, AND IS ACTIVELY BEING OFFERED FOR SALE, LEASE, OR RENT. I. THE OWNER OF ANY BOARDED BUILDING, WHETHER BOARDED BY VOLUNTARY ACTION OF THE OWNER OR AS A RESULT OF ENFORCEMENT ACTIVITY BY THE CITY, SHALL CAUSE THE BOARDED BUILDING TO BE REHABILITATED FOR OCCUPANCY WITHIN NINETY (90) DAYS AFTER THE BUILDING IS BOARDED AND SHALL COMPLY WITH THE PROVISIONS OF SUBSECTIONS A THROUGH H OF THIS SECTION, AS WELL AS ALL OTHER PROVISIONS OF THE CITY CODE. J. IT IS DECLARED A PUBLIC NUISANCE FOR ANY PERSON, PARTNERSHIP, ASSOCIATION, CORPORATION, FIDUCIARY, OR OTHER LEGAL ENTITY THAT OWNS, LEASES, OCCUPIES, CONTROLS OR MANAGES ANY BUILDING OR PROPERTY SUBJECT TO THIS CHAPTER TO CAUSE, PERMIT, OR MAINTAIN SUCH BUILDING OR PROPERTY IN VIOLATION OF SUBSECTIONS A THROUGH I OF THIS SECTION. K. K. WITHIN THIRTY (30) DAYS AFTER A PROPERTY BECOMES A VACANT BUILDING AS DEFINED HEREIN, THE OWNER OF A VACANT RESIDENTIAL, COMMERCIAL, HISTORICAL, OR INDUSTRIAL BUILDING SHALL CAUSE SAID BUILDING TO BE REGISTERED AS A VACANT BUILDING PURSUANT TO THE PROVISIONS OF SECTION 8-1985 OF THIS CHAPTER AND SHALL PAY THE REGISTRATION FEE REQUIRED PER SECTION 8-1989. FURTHER, THE OWNER OF SAID VACANT BUILDING SHALL COMPLY WITH ALL APPLICABLE PROVISIONS OF THIS CODE WITH RESPECT TO PROPERTY MAINTENANCE, NUISANCE ABATEMENT, LOCAL PROPERTY MANAGEMENT REQUIREMENTS AND MONITORING. SAMC 8-1987. - SECURITY REQUIREMENTS. A. ABANDONED AND VACANT PROPERTIES SHALL BE SECURED SO AS NOT TO BE ACCESSIBLE TO UNAUTHORIZED PERSONS. B. SECURING OF VACANT OR ABANDONED PROPERTY INCLUDES BUT IS NOT LIMITED TO CLOSING AND LOCKING OF WINDOWS, DOORS (WALK-THROUGH, SLIDING AND GARAGE), GATES AND ANY OTHER OPENING THAT MAY ALLOW ACCESS TO THE INTERIOR OF THE PROPERTY AND OR STRUCTURE^). IN THE CASE OF BROKEN WINDOWS SECURING MEANS RE-GLAZING OR BOARDING THE WINDOW. IF DEEMED NECESSARY BY THE CODE ENFORCEMENT MANAGER, SECURING OF VACANT OR ABANDONED PROPERTY MAY REQUIRE THE PROVISION OF ON-SITE SECURITY GUARD SERVICES. SUCH SERVICES SHALL BE OF SUFFICIENT DURATION AND FREQUENCY TO ENSURE THAT THE PROPERTY REMAINS SECURE AND NO UNAUTHORIZED PERSONS MAY GAIN ENTRY. C. IF THE VACANT OR ABANDONED PROPERTY IS OWNED BY A CORPORATION AND/OR OUT OF AREA BENEFICIARY/TRUSTEE/OWNER, A LOCAL PROPERTY MANAGEMENT COMPANY SHALL BE CONTRACTED TO PERFORM WEEKLY INSPECTIONS TO VERIFY THAT THE ABANDONED PROPERTY IS MAINTAINED IN ACCORDANCE WITH THE REQUIREMENTS OF THIS SECTION, AND ANY OTHER APPLICABLE LAWS. D. THE PROPERTY SHALL BE POSTED WITH THE NAME AND 24-HOUR CONTACT PHONE NUMBER OF THE LOCAL PROPERTY MANAGEMENT COMPANY. THE POSTING SHALL BE NO LESS THAN EIGHTEEN (18) INCHES X TWENTY-FOUR (24) INCHES, SHALL BE OF A FONT THAT IS LEGIBLE FROM A DISTANCE OF FORTY-FIVE (45) FEET, AND SHALL CONTAIN THE FOLLOWING VERBIAGE;"THIS PROPERTY MANAGED BY________," AND "TO REPORT PROBLEMS OR CONCERNS CALL(NAME AND PHONE NUMBER)." E. THE POSTING SHALL BE PLACED ON THE INTERIOR OF A WINDOW FACING THE STREET TO THE FRONT OF THE PROPERTY SO IT IS VISIBLE FROM THE STREET, OR SECURED TO THE EXTERIOR OF THE BUILDING/STRUCTURE FACING THE STREET OF THE FRONT OF THE PROPERTY SO IT IS VISIBLE FROM THE STREET. IF NO SUCH AREA EXISTS, THE POSTING SHALL BE ON A STAKE OF SUFFICIENT SIZE TO SUPPORT THE POSTING, IN A LOCATION THAT IS VISIBLE FROM THE STREET TO THE FRONT OF THE PROPERTY, AND TO THE EXTENT POSSIBLE, NOT READILY SUBJECT TO POTENTIAL VANDALISM. EXTERIOR POSTING MUST BE CONSTRUCTED OF, AND PRINTED WITH WEATHER RESISTANT MATERIALS. F. THE LOCAL PROPERTY MANAGEMENT COMPANY SHALL INSPECT THE PROPERTY ON A WEEKLY BASIS, OR MORE FREQUENTLY, TO DETERMINE IF THE PROPERTY IS IN COMPLIANCE WITH THE REQUIREMENTS OF THIS DIVISION. IF IT IS DETERMINED THAT THE PROPERTY IS NOT IN COMPLIANCE, IT IS THE COMPANY'S RESPONSIBILITY TO BRING THE PROPERTY INTO COMPLIANCE. G. THE DUTIES AND OBLIGATIONS SPECIFIED IN THIS SECTION SHALL BE JOINT AND SEVERAL AMONG AND BETWEEN ALL TRUSTEES AND BENEFICIARIES AND THEIR RESPECTIVE AGENTS. H. BONDING AND FENCING REQUIREMENTS FOR VACANT BUILDINGS. SYMBOLS LEGEND DRAINAGE DIRECTION AND SLOPE PROPERTY LINE CORNER POINTS AND ELEVATION DATUM KEYNOTE CALLOUTS EXISTING WALL TO REMAIN AND NEW WALLS WALL TO BE DEMOLISHED 2% # 3/32" = 1'-0"2PROPOSED SITE PLAN / ROOF PLAN 1 04/02/2025 PLAN CHECK RESUBMITTAL PARK & REC DEVELOPMENT FEE CALCULATION ADU SF / SFD SF = RATIO 990 SF / 991 SF = 0.99 THE ADU SF/ SFD RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN SFR SF OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN SFR SF. 2 06/19/2025 PLAN CHECK RESUBMITTAL 2 2 06/19/2025 PLAN CHECK RESUBMITTAL 3 10/09/2025 REVISION NOT USED NOT USED 3 33 TITLE 24 T24-1 Job # Sheet No.: Scale Date Pl a n C h e c k # : __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ SEAL: SHEET DESCRIPTION : 08/19/2024 S24211 DE T A C H E D A D U 14 1 1 W 7 T H S T , SA N T A A N A , C A 9 2 7 0 3 Pr o j e c t f o r : CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:1411 W 7th St - ADU Calculation Date/Time:2025-10-20T22:10:23-07:00 (Page 1 of 11) Calculation Description:Title 24 Analysis Input File Name:1411 W 7th St - T24.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-10-20   22:10:51 GENERAL INFORMATION 01 Project Name 1411 W 7th St - ADU 02 Run Title Title 24 Analysis 03 Project Location 1411 W 7th St 04 City Santa Ana 05 Standards Version 2022 06 Zip code 92703 07 Software Version EnergyPro 9.2 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)90 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 3 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)990 19 Glazing Percentage (%)13.43% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type All electric 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 425-P010316798A-000-000-0000000-0000 10/20/2025 22:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:1411 W 7th St - ADU Calculation Date/Time:2025-10-20T22:10:23-07:00 (Page 2 of 11) Calculation Description:Title 24 Analysis Input File Name:1411 W 7th St - T24.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-10-20   22:10:51 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 34.2 40.9 32.6 Proposed Design 34.1 39.8 31.9 0.1 1.1 0.7 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 2.40 kWdc •PV System resized to 2.40 kWdc (a factor of 2.399) to achieve 'Standard Design PV' PV scaling 425-P010316798A-000-000-0000000-0000 10/20/2025 22:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:1411 W 7th St - ADU Calculation Date/Time:2025-10-20T22:10:23-07:00 (Page 3 of 11) Calculation Description:Title 24 Analysis Input File Name:1411 W 7th St - T24.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-10-20   22:10:51 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.03 0.19 0.88 6.52 -0.85 -6.33 Space Cooling 1.14 26.23 0.77 23.02 0.37 3.21 IAQ Ventilation 0.47 4.89 0.47 4.89 0 0 Water Heating 2.01 21.35 1.54 16.75 0.47 4.6 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 3.65 52.66 3.66 51.18 -0.01 1.48 Photovoltaics -2.66 -81.3 -2.66 -80.9 Battery 0 0 Flexibility Indoor Lighting 0.86 8.08 0.86 8.08 Appl. & Cooking 4.1 49.2 4.04 48.64 Plug Loads 5.53 56.31 5.53 56.31 Outdoor Lighting 0.2 1.75 0.2 1.75 TOTAL COMPLIANCE 11.68 86.7 11.63 85.06 425-P010316798A-000-000-0000000-0000 10/20/2025 22:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:1411 W 7th St - ADU Calculation Date/Time:2025-10-20T22:10:23-07:00 (Page 4 of 11) Calculation Description:Title 24 Analysis Input File Name:1411 W 7th St - T24.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-10-20   22:10:51 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 19.96 19.32 0.64 3.21 Net EUI2 6.44 5.81 0.63 9.78 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 2.4 NA Standard (14-17%)Fixed none true 150-270 n/a n/a <=7:12 96 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Fan Efficacy Watts/CFM •Verified heat pump rated heating capacity •Duct leakage testing 425-P010316798A-000-000-0000000-0000 10/20/2025 22:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:1411 W 7th St - ADU Calculation Date/Time:2025-10-20T22:10:23-07:00 (Page 5 of 11) Calculation Description:Title 24 Analysis Input File Name:1411 W 7th St - T24.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-10-20   22:10:51 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 1411 W 7th St - ADU 990 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status ADU Area Conditioned New Heat Pump1 990 8 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) North Wall ADU Area R-15 Wall 0 Right 212 41.8 90 South Wall ADU Area R-15 Wall 0 Right 152 60 90 East Wall ADU Area R-15 Wall 90 Front 184 29 90 West Wall ADU Area R-15 Wall 270 Back 184 40 90 Roof ADU Area R-30 + R-15 Roof Attic n/a n/a 990 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic ADU Area Attic RoofADU Area Ventilated 4 0.1 0.85 Yes No 425-P010316798A-000-000-0000000-0000 10/20/2025 22:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:1411 W 7th St - ADU Calculation Date/Time:2025-10-20T22:10:23-07:00 (Page 6 of 11) Calculation Description:Title 24 Analysis Input File Name:1411 W 7th St - T24.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-10-20   22:10:51 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading WA-5040 Window North Wall Right 0 1 20 0.3 NFRC 0.22 NFRC Bug Screen WC-2020 Window North Wall Right 0 1 4 0.3 NFRC 0.22 NFRC Bug Screen WA-5040 2 Window South Wall Right 0 1 20 0.3 NFRC 0.22 NFRC Bug Screen WA-5040 3 Window South Wall Right 0 1 20 0.3 NFRC 0.22 NFRC Bug Screen WB-3030 Window East Wall Front 90 1 9 0.3 NFRC 0.22 NFRC Bug Screen WA-5040 4 Window East Wall Front 90 1 20 0.3 NFRC 0.22 NFRC Bug Screen WA-5040 5 Window West Wall Back 270 1 20 0.3 NFRC 0.22 NFRC Bug Screen WA-5040 6 Window West Wall Back 270 1 20 0.3 NFRC 0.22 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor D1.1-2868 North Wall 17.8 0.5 D3-3068 South Wall 20 0.5 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade ADU Area 990 0.1 none 0 80%No 425-P010316798A-000-000-0000000-0000 10/20/2025 22:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:1411 W 7th St - ADU Calculation Date/Time:2025-10-20T22:10:23-07:00 (Page 7 of 11) Calculation Description:Title 24 Analysis Input File Name:1411 W 7th St - T24.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-10-20   22:10:51 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco Attic RoofADU Area Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-15 None / 0 0.07 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-2.0 insul. R-30 + R-15 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032 Over Ceiling Joists: R-20.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) 425-P010316798A-000-000-0000000-0000 10/20/2025 22:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:1411 W 7th St - ADU Calculation Date/Time:2025-10-20T22:10:23-07:00 (Page 8 of 11) Calculation Description:Title 24 Analysis Input File Name:1411 W 7th St - T24.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-10-20   22:10:51 WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 40 Rheem PROPH40 T2 RH37515 (40 gal, JA13) Outside ADU Area ADU Area WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type New Heat Pump1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 HVAC Fan 1 Air Distribution System 1 Setback HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Central split HP 1 HSPF 8.8 24000 20000 EERSEER 15 12.2 Not Zonal Single Speed Heat Pump System 1-hers-htpump 425-P010316798A-000-000-0000000-0000 10/20/2025 22:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:1411 W 7th St - ADU Calculation Date/Time:2025-10-20T22:10:23-07:00 (Page 9 of 11) Calculation Description:Title 24 Analysis Input File Name:1411 W 7th St - T24.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-10-20   22:10:51 HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 350 Not Required Not Required No No Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Sealed and Tested Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan 425-P010316798A-000-000-0000000-0000 10/20/2025 22:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:1411 W 7th St - ADU Calculation Date/Time:2025-10-20T22:10:23-07:00 (Page 10 of 11) Calculation Description:Title 24 Analysis Input File Name:1411 W 7th St - T24.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-10-20   22:10:51 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 59 0.35 Exhaust No n/a / n/a No Yes 425-P010316798A-000-000-0000000-0000 10/20/2025 22:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:1411 W 7th St - ADU Calculation Date/Time:2025-10-20T22:10:23-07:00 (Page 11 of 11) Calculation Description:Title 24 Analysis Input File Name:1411 W 7th St - T24.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-10-20   22:10:51 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Trang Ho PM GROUP 10/20/2025 7634 NANCY LN STANTON, CA 90680 1742131608 Trang Ho PM GROUP 10/20/2025 7634 NANCY LN STANTON, CA 90680 1742131608 425-P010316798A-000-000-0000000-0000 10/20/2025 22:12 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.