Loading...
HomeMy WebLinkAbout2709 N Dayna Street - Plan Name: Address: Thank you, 1833 S. Victory Blvd. Glendale, CA 91201 Toll-Free 800.552.9970 | Office 818.804.3122 | Fax 818.804.3123 www.SolarOptimum.com 2709 Dayna Street, Santa Ana, CA 92705 Jeffrey Cheng I give permission to Solar Optimum to install 10.88 KS PV SYSTEM 25 PV MODULES 1-TESLA POWERWALL 3 ESS 1-TESLA POWERWALL 3 EXPANSION UNIT Docusign Envelope ID: FCA229CC-3183-4147-9550-9E1B38C3C3AF 10/20/2025 Certificate Of Completion Envelope Id: FCA229CC-3183-4147-9550-9E1B38C3C3AF Status: Completed Subject: Complete with Docusign: Homeowner authorization letter to install solar panels.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 4 Initials: 0 Permitting Team AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 614 W Colorado St Glendale, CA 91204-1104 permitting@solaroptimum.com IP Address: 104.15.149.101 Record Tracking Status: Original 10/20/2025 2:23:09 PM Holder: Permitting Team permitting@solaroptimum.com Location: DocuSign Signer Events Signature Timestamp Jeffrey Cheng jeffreycheng92@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Drawn on Device Using IP Address: 2001:57a:e207:12e0:41c:7f93:f09f:8865 Signed using mobile Sent: 10/20/2025 2:23:59 PM Viewed: 10/20/2025 2:34:04 PM Signed: 10/20/2025 2:34:13 PM Electronic Record and Signature Disclosure: Accepted: 10/20/2025 2:34:04 PM ID: 3ec847b4-b59a-4e26-ae74-a8e5408f35f7 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 10/20/2025 2:23:59 PM Certified Delivered Security Checked 10/20/2025 2:34:04 PM Signing Complete Security Checked 10/20/2025 2:34:13 PM Completed Security Checked 10/20/2025 2:34:13 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, Solar Optimum, Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to these terms and conditions, please confirm your agreement by clicking the ‘I agree’ button at the bottom of this document. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures Electronic Record and Signature Disclosure created on: 9/24/2015 10:32:27 AM Parties agreed to: Jeffrey Cheng electronically from us. How to contact Solar Optimum, Inc. : You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: accounting@solaroptimum.com To advise Solar Optimum, Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at accounting@solaroptimum.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address.. In addition, you must notify DocuSign, Inc. to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from Solar Optimum, Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an e-mail to accounting@solaroptimum.com and in the body of such request you must state your e-mail address, full name, US Postal address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with Solar Optimum, Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an e-mail to accounting@solaroptimum.com and in the body of such request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that: • I can access and read this Electronic CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC RECORD AND SIGNATURE DISCLOSURES document; and • I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and • Until or unless I notify Solar Optimum, Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by Solar Optimum, Inc. during the course of my relationship with you. REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI COVER SHEET SCOPE OF WORK SYSTEM SIZE: 25 X 435 = 10.88KW CEC AC: 9.92KW MODULES: (25) MISSION SOLAR: MSX10-435HN0B 435W MODULES MCI: (09) TESLA MCI-2 (240V) MODULE MAX POWER (P/MAX): 435W INVERTER: (01) TESLA POWERWALL 3 @ (240V) (01) TESLA POWERWALL 3 EXPANSION UNIT RACKING: UNIRAC LIGHT RAIL ATTACHMENT: UNIRAC FLASH LOC DUO VICINITY MAP GENERAL NOTES: CODE SUMMARY THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA PLUMBING CODE 2020 NATIONAL ELECTRICAL CODE ALL OTHER ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGENCIES. ·LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. ·THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES ·PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED ·ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED ·ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703, UL1741 AND UL1703 ·ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT ·THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED ·THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS ·IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE, IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE ·EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" ·A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH CAL-OSHA REGULATIONS ·PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER, AND SYSTEM COMPLIES WITH 690.35. ·MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. ·INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. ·ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED, LABELED, AND INSTALLED PER THE NEC, THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. ·CONDUITS AND CABLES EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8" ABOVE ROOF SURFACE. NEC 310.15(B)(3)(c) ·THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTAND A MINIMUM 110 MPH WIND LOAD. BUILDING INFORMATION: 1 STORY HOUSE TYPE OF CONSTRUCTION: V-B OCCUPANCY: RESIDENTIAL GROUP R - 3 ASSESSOR PARCEL: 39053211 ROOF TYPE: COMPOSITE SHINGLE ROOF RAFTERS: 2"X6" @ 24" O.C. ELECTRICAL INFORMATION UTILITY COMPANY: SCE (UNDERGROUND) MAIN SERVICE AMPERAGE: 225A ARRAY TILT:ARRAY AZIMUTH: #1 - 22°#1 - 180° #2 - 22°#2 - 90° TABLE OF CONTENTS PAGE #DESCRIPTION PV 1 COVER SHEET PV 2 SITE PLAN PV 3 ARRAY DETAIL PV 4 STRING LAYOUT PV 5-6B ATTACHMENT DETAIL PV 7 ELECTRICAL DIAGRAM PV 8 ELECTRICAL CALCULATION PV 9 PLACARD PV 10+SPEC SHEETS MSP UMPW3DC ACD BAT JB ACD 58 ' - 8 " 102'-9" 102'-9" 58 ' - 8 " SITE PLAN REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SITE PLAN: SCALE:- 3/32" = 1'-0" ARRAY PITCH AZIMUTH SOLAR AREA (SQFT) SOLAR LOAD (LBS) ROOF AREA (SQFT) ROOF AREA COVERED BY SOLAR # MODULES #1 22°180°526.50 1174.00 3071.49 17.14%08 #2 22°90°17 ·FOR PHOTOVOLTAIC ARRAYS OCCUPYING 33% OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A MINIMUM 18" SETBACK IS REQUIRED ON BOTH SIDES OF HORIZONTAL RIDGE. CFC 605.11.2.2 (IRC R324.6.2) ·TOTAL SOLAR AREA: 526.50 SQFT ·TOTAL ROOF AREA: 3071.49 SQFT ·TOTAL ROOF AREA COVERED BY SOLAR: 17.14% LEGEND MSP MAIN SERVICE PANEL UM UTILITY METER JB JUNCTION BOX ACD AC DISCONNECT BAT POWERWALL 3 EXPANSION TPW TESLA POWERWALL 3 DC DC DISCONNECT MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 25 MODULES MODULE TYPE = MISSION SOLAR MSX10-435HN0B 435W MODULES MODULE WEIGHT = 46.96LBS / 21.3KG. MODULE DIMENSIONS = 67.80" x 44.73" = 21.06 SF UNIT WEIGHT OF ARRAY = 2.22 PSF PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E ARRAY #1 (8) MISSION SOLAR: MSX10-435HN0B 435W MODULES ARRAY #2 (17) MISSION SOLAR: MSX10-435HN0B 435W MODULES (E) CHIMNEY (E) FENCE (E) GATE ROOF ACCESS POINT DRIVEWAY (N) 3/4" CONDUIT RUN MIN. 7/8" ABOVE ROOF (N) JUNCTION BOX ON ROOF (N) TESLA POWERWALL 3 DC EXPANSION UNIT (N) TESLA POWERWALL 3 (N) 60A FUSED AC DISCONNECT (N) DC DISCONNECT (N) 60A AC DISCONNECT (E) 225A MAIN SERVICE PANEL, 240V (E) UTILITY METER (N) TESLA BACKUP SWITCH 18 " F I R E S E T B A C K 18 " F I R E S E T B A C K 36" FIRE SETBACK DA Y N A S T 36" FIRE SETBACK UM PW 3 DC BA T JB AC D REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI ARRAY DETAIL # MODULES PER ARRAY ROOF TYPE ATTACHMENT ROOF HEIGHT FRAME MATERIAL FRAME TYPE FRAME SIZE OC SPACING AR-01 8 COMPOSITE SHINGLE UNIRAC FLASH LOC DUO 1 STORY WOOD RAFTERS 2"X6"24" O.C. AR-02 17 COMPOSITE SHINGLE UNIRAC FLASH LOC DUO 1 STORY WOOD RAFTERS 2"X6"24" O.C. LOAD CALCULATION ITEM #OR LIN FT WEIGHT PER (lbs) TOTAL WEIGHT (lbs) MODULES 25 47.0 1174.00 RAILS 309.71 0.4 135.0 ATTACHMENTS 44 0.65 28.60 TILT LEGS 0 3.5 0 RSD 9 0.4 3.6 TOTAL WEIGHT 1341.2 WEIGHT PER MOUNT 1341.2 / 44 = 30.5 lbs/Mount lbs AR-01 - SCALE: 1/8" = 1'-0" PITCH: 22° AZIMUTH: 180° 2"X6" RAFTERS @ 24" O.C. UNIRAC FLASH LOC DUO ATTACHMENT @ 72" O.C. (N) 06 TESLA RSD MCI-2 (N) 03 TESLA RSD MCI-2 (N) UNIRAC SOLARMOUNT LIGHT RACKING SYSTEM AR-02 - SCALE: 1/8" = 1'-0" PITCH: 22° AZIMUTH: 90° MODULES: 25 MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 110 MPH 3-SEC GUST. LAG SCREWS: 5/16" X 3-1/2" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. DESIGN CRITERIA 1'-10" 11 ' - 5 " 3' - 1 1 " 16'-7"20'-10"15'-7" 8'-2"38'6'-9" 1'-6" 11 ' - 5 " 7' - 5 " 3'-8" TYP. 6' TYP. MSP UMPW3DC ACD BAT JB ACD REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI STRING LAYOUT (25) MISSION SOLAR MSX10-435HN0B 435W MODULES (1) STRING OF 09 MODULES CONNECTED IN PARALLEL. (2) STRINGS OF 08 MODULES CONNECTED IN PARALLEL. STRING LAYOUT: SCALE:- 1/8"=1'-0"BILL OF MATERIALS EQUIPMENT QTY SOLAR PV MODULE 25 RSD 9 AC DISCONNECT 2 POWERWALL 3 1 POWERWALL 3 EXPANSION 1 DC DISCONNECT 1 BACKUP SWITCH 1 ATTACHMENT 44 RAILS 168"13 RAIL SPLICE 6 MID CLAMPS 22 END CLAMPS 16 GROUNDING LUG 4 DA Y N A S T A-1 A-2 A-3 A-4 A-5 A-6 A-7 A-8 A-9 B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 C-5 C-6 C-7 C-8 C-4 C-3 C-2 C-1 REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI ATTACHMENT DETAIL 2 ATTACHMENT DETAIL ( section view) PV-5 SCALE: NTS 1 ATTACHMENT DETAIL PV-5 SCALE: NTSSCALE: 1"=1' UNIRAC LIGHT RAIL (TYP.) GROUNDING MID/END CLAMP 2"X6" RAFTER @ 24" O.C. UNIRAC FLASH LOC DUO (2) #12-14 SCREW HWH, SS, SELF DR WITH #12 EPDM WASHER (2) #12-14 SCREW HWH, SS, SELF DR WITH #12 EPDM WASHER (E) ROOF SHEATHING ASPHALT SHINGLE ROOF 2"X6" RAFTER @ 24" O.C. SS SERRATED FLANGE NUT SOLAR MODULE GROUNDING END CLAMP UNIRAC LIGHT RAIL (TYP.) UNIRAC FLASH LOC DUO ~6 " TESLA POWERWALL 3 TESLA POWERWALL 3 DC EXPANSION UNIT REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI ATTACHMENT DETAIL 2 ELECTRICAL EQUIPMENT ELEVATION SCALE: NTSPV-6 1 CONDUIT DETAILS SCALE: NTSPV-6 (4) 1/4" x 3-1/2" LAG BOLTS W/ MIN. 2-1/2" EMBEDMENT (2 TOP & 2 BOTTOM) IN TO (E) STUDS USING 2 STUDS MIN. TESLA POWERWALL 3 (E) 2"x4" WALL STUDS TESLA POWERWALL 3 WALL-MOUNTED DETAIL STRAIN RELIEF J-BOX RAIN TIGHT, STEEL EMT CONNECTOR CONDUIT ABOVE ROOF TO LOAD CENTER/MAIN SERVICE STRUT STRAP EMT CONDUIT APPROVED LONG LASTING BLOCK (N) 60A FUSED AC DISCONNECT (N) DC DISCONNECT (N) 60A AC DISCONNECT (E) 225A MAIN SERVICE PANEL, 240V (E) UTILITY METER (N) TESLA BACKUP SWITCH (E) WINDOWS ELECTRICAL EQUIPMENT LOCATION SOUTH WALL PV ARRAY 1'1' REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6A CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI ATTACHMENT DETAIL 1 SECURE FIRST END SCALE: NTSPV-6A REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6B CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI ATTACHMENT DETAIL 1 GROUNDING DETAIL SCALE: NTSPV-6B REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI ELECTRICAL 1 STRING B2 (N) JUNCTION BOX NEMA 3R UL LISTED 1 1 STRING A2 9 8 SHIELDED VNTC CABLE (600V) (4) #18 AWG THWN-2 G BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V, 60Hz TO UTILITY GRID GROUNDING ELECTRODE SYSTEM (E) MAIN SERVICE PANEL, 225A RATED, 240V M (N) TESLA BACKUP SWITCH 60A PROJECT DESCRIPTION:- MODULES: (N) (25) MISSION SOLAR: MSX10-435HN0B 435W MODULES SYSTEM SIZE: 10.88 KW INVERTER: (N) (1) TESLA POWERWALL 3 11.5KW, (240V) BATTERY: (N) (1) TESLA POWERWALL 3 EXPANSION UNIT RSD: (N) (09) TESLA RSD MCI-2 NOTES: ·ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. ·THE ESS CIRCUIT BREAKER SHALL BE SECURED IN PLACE BY AN ADDITIONAL FASTENER PER SECTION 408.36(D). THE BREAKER AND FASTENER SHALL BE MADE BY THE SAME MANUFACTURER. ·THE BACKFEED BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE MAIN BREAKER OR INPUT FEEDER. ·TERMINATION POINTS FOR ELECTRICAL EQUIPMENT ARE RATED FOR 60/75 DEGREES CELSIUS. ·THE DISTANCE FOR RELOCATED LOADS IS LESS THAN 6 ft. ·DISTANCE BETWEEN ESD AND SUBPANEL < 5'. CONDUIT SCHEDULE GROUND #CONDUIT CONDUCTOR (RED/BLACK)NEUTRAL (WHITE)CONDUCTOR (CONTROL CABLE)(GREEN)(BARE COPPER) 1 FREE AIR (6) 10 AWG PV WIRE/USE-2 NONE NONE (1) 6 AWG 2 3/4" EMT (6) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 NONE 3 3/4" EMT (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 NONE FROM THE RSD CONNECTOR IN THE TESLA POWERWALL 3 REMOVE THE FACTORY JUMPERS AND FEED A SECOND SYSTEM SHUTDOWN SWITCH SOLAR SHUTDOWN DEVICE MID-CIRCUIT INTERRUPTER (MCI) IS PART OF THE PV SYSTEM RAPID SHUTDOWN (RSD) FUNTION IN ACCORDANCE WITH ARTICLE 690 OF THE APPLICABLE NEC (N) AC DISCONNECT: 240V, 60A NON FUSED NEMA 3R, UL LISTED DC AC (N) TESLA POWERWALL 3 11.5kW, 48A, 240V NEMA 3R, UL LISTED BATTERY MPPT #1 MPPT #2 12V GND CN+CN- MPPT #3 MPPT #4 MPPT #5 MPPT #6 (N) DC DISCONNECT IMO 600V SI16-PEL64R-2 (2) #14 THWN-2 3 TESLA POWERWALL 3 EXPANSION UNIT 11.5 KW , 48 A , 240V NEMA 3R. UL LISTED BATTERY EXPANSION HARNESS MISSION SOLAR: MSX10-435HN0B 435W MODULES (3) TESLA RSD MCI-2, 240V (1) STRING OF (8) MODULES 3 INCLUDED WITH SEPARATE ENERGY STORAGE BATTERY AGREEMENT 2 (12) TESLA RSD MCI-2 MISSION SOLAR: MSX10-435HN0B 435W MODULES (3) TESLA RSD MCI-2, 240V (1) STRING OF (8) MODULES MISSION SOLAR: MSX10-435HN0B 435W MODULES (3) TESLA RSD MCI-2, 240V (1) STRING OF (9) MODULES 1 STRING C2 8 (N) AC DISCONNECT: 240V, 60A FUSED NEMA 3R, UL LISTED 60A FUSED 3 (N) 60A BACKFEED BREAKER AT THE OPPOSITE END OF THE MAIN SERVICE BUSBAR FROM THE MAIN OVER CURRENT DEVICE. (E) MAIN BREAKER 200A/2P RATED, 240V (E) 225A MAIN SERVICE PANEL 120% RULE - NEC 705.15 (B)(3)(2) UTILITY FEED + ESS + SOLAR BACKFEED 200A + 60A = 260A BUS RATING x 120% 225A x 120% = 270A SERVICE INFO UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: SCE 240V SQUARE D SOUTH WALL UNDERGROUND 225A MAIN BREAKER 200A REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI WIRING CALCULATIONS ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 AMBIENT TEMPERATURE SPECS AMBIENT TEMP (HIGH TEMP 2%) RECORD LOW TEMP 1° 33° CONDUIT HEIGHT 7/8" ROOF TOP TEMP 75° CONDUCTOR TEMPERATURE RATE 75° OPTIMIZER SPECIFICATIONS POWER OPTIMIZER TESLA PV RAPID SHUTDOWN NOMNAL INPUT DC CURRENT 13A MAX INPUT SHORT CIRCUIT CURRENT 15A DC INPUT POWER 1000VDC DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER: AC CONDUCTOR AMPACITY CALCULATIONS: INVERTER TO EX MSP. EXPECTED WIRE TEMP (In Celsius)33° TEMP. CORRECTION PER TABLE (310.16)0.94 NO. OF CURRENT CARRYING CONDUCTORS 6 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 35A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 18.75A 1.25 X MAX. DC OUTPUT CURRENT (RSD) DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 32.90ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity EXPECTED WIRE TEMP (In Celsius)33° TEMP. CORRECTION PER TABLE (310.16)0.94 NO. OF CURRENT CARRYING CONDUCTORS 6 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 35A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 18.75A 1.25 X MAX. DC OUTPUT CURRENT (RSD) DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 26.32ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity No. OF INVERTER 1 EXPECTED WIRE TEMP (In Celsius)33° TEMP. CORRECTION PER TABLE (310.16)0.94 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1 CIRCUIT CONDUCTOR SIZE 6AWG CIRCUIT CONDUCTOR AMPACITY 65A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 60.00A 1.25 X MAX INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 61.10ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (60.00A) otherwise less the entry for circuit conductor size and ampacity SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # VMP IMP VOC ISC MISSION SOLAR MSX10-435HN0B 435W MODULES MODULE DIMENSION 33.31V 13.07A 39.56V 13.79A 67.8"L x 44.73"W x 1.18"D (In Inch) MODULE TEMPERATURE COEFFICIENT OF Voc -0.24%/°C MSP UMPW3DC ACD BAT JB ACD REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI PLACARDS CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN 2709 DAYNA ST, SANTA ANA, CA 92705 ADHESIVE FASTENED SIGNS: ·THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. ·WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. ·ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] SIGNAGE FORMAT: ALL LETTERS SHALL BE CAPITALIZED, 3/8" WHITE LETTERING ON RED BACKGROUND, ARIAL OR SIMILAR FONT, NON-BOLD; REFLECTIVE, ON WEATHER- RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING) WILL BE USED; DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT. LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION LABEL LOCATION: CONDUIT, COMBINER BOX WARNING: PHOTOVOLTAIC POWER SOURCE WARNING ELECTRIC SHOCK HAZARD LABEL LOCATION: DC DISCONNECT, INVERTER IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED PV/BATTERY DISCONNECT RATED AC OPERATING CURRENT 48.00 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS ! NOTICE PV SYSTEM COMBINER PANEL DO NOT ADD LOADS TO THIS PANEL LABEL LOCATION: LOAD CENTER [Only use when applicable for PV load center] SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN WARNING PHOTOVOLTAIC SYSTEM DO NOT RELOCATE THIS BREAKER LABEL LOCATION: POINT OF INTERCONNECTION [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] ! LABEL LOCATION: POINT OF INTERCONNECTION WARNING TRI POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER [To be used when inverter is ungrounded] ! WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION ! RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: PV SOLAR SHUTDOWN SWITCH NO MORE THAN 3FT FROM THE SWITCH TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY PHOTOVOLTAIC DC DISCONNECT ADC VDC VDC ADC LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). RATED MAXIMUM POWER-POINT CURRENT: RATED MAXIMUM POWER-POINT VOLTAGE: MAXIMUM SYSTEM VOLTAGE: MAXIMUM SHORT CIRCUIT CURRENT: 11.89 336.8 390.4 12.85 ! PER THE 2022 CEC 705.10. CAUTION : MULTIPLE SOURCES OF POWER. DA Y N A S T TESLA POWERWALL 3 DC EXPANSION UNIT TESLA POWERWALL 3 225A MAIN SERVICE PANEL UTILITY METER TESLA BACKUP SWITCH FUSED AC DISCONNECT DC DISCONNECT AC DISCONNECT PV ARRAY REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-14 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-15 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-16 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-17 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-18 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-19 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-20 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-21 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-22 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-23 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-24 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-25 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-26 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JE F F R E Y C H E N G ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-27 CONTRACTOR NAME CONTRACTOR INFORMATION PH O N E : - +1 4 1 5 3 6 1 0 8 4 5 27 0 9 D A Y N A S T , SA N T A A N A , C A 9 2 7 0 5 AH J : - SA N T A A N A C I T Y CO U N T Y : - (O R A N G E C O U N T Y ) SOLAR OPTIMUM 501 W. GLENOAKS BLVD #555 GLENDALE, CA, 91202 (818) 804-3122 CALIFORNIA C-10 LIC# 972228 ARPIAR TARVERDI SPECS SHEET Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 2709 Dayna Street, Santa Ana, CA 92705 SOLAR OPTIMUM 972228 X X X X X X X X X X LORENA HERNANDEZ 818-804-3122 09/22/25 lorenahernandez@solaroptimum.com