Loading...
HomeMy WebLinkAbout10196163 - PermitCity of Santa Ana Permit Counter: (714) 647-5800 :r0 Civic Center Plaza (M-19), Sa,',ta Ana, CA92702 lnspection Requests: (714) 667-2738 lnspector Sectionr (714\ 647-5853 Bu ild ing Permit #: lO{96{63 Pin #: 6983{ q Project Address: 1319 S Po rlaf.9l Assessor's Parcel:'t09-274-05 Lot: 47 Unit Bldg. Address Range:Suile Range: Zoning: RlBlockr NA Itacl. 1574 Hisloric. No Building Usel Job Type: Nature of Work: Existing Bldg. & Use Proposed Use: Single Family Owelling Patio Cover Reroof/Windows/Patio SFD w/att garage Occupancy: Constr Type Code: Flood Zone # of Stories: R.3, U VB cBc 2016 x4602320257 J 1st FL Area: 2nd FL Area: Other Areas: Garage Area Total: Patio: 380 T.l.Area: Yards Req'd: Valuation: $19,500.00 Description of Work: Add attachod patio cover ESR-2676P/change out windows-same size, same style/Reroof w/t.o.-Remove and apply comp shingles/replace sheathing as req'd/handout given Planning Conditions: Ownerl Address Desiree Garza 1319 S Poplar St Santa Ana, CA 92704 Contractor: J D F Construction lnc Address: 201 Gemini Ave Brea, CA 92821 Phone: (714) 729-0680 Slate Lic #: 956749 Lic Type: B, C-20, C-39 Bus. Lic #: 340898 Workers' Compensation lnsurance: Carrier: Falls Lake Fire and Casualty ComF Policy #: FLA000855 Expires: 08/15/2018 Engineer Address Archatect / Desiqner: Address: Planning Approval By: Plan Checked By: Permit lssued By: NPDES lnsp. Req'd: PWA lnsp. Req'd: Planning lnsp. Req'd: Landscaping lnsp. Req'd $lr'r",n"no"r, xutny Dale: 0411712018 Date: Oale 0411712018 Subject to Field Misc. Receipt Misc. Receipl Misic. Receipt 07776002 o89o70oI 0 777600 2 o177600 2 0 777600 2 51JA01 21000 57672 s7600 51607 Permil Foe SMIP - Category 1 Bldg. Stds. Revolving General Plan Update lssuance Ni, Ann $612 78 s2.54 $1.00 $21 .25 $52.98No No No No Fire lnsp. Req'd: Police lnsp. Req'd NoNo Account#Total Flood Zone Cerl. Req'd: No Every pemit issued shall becoma invalid unless th€ wolr( on the site authotized by such pemil is commenced wihin 180 days afret ils issuance.or if lhe wo* aulhonzed on tha sile by such pemit is suspended or abandoned fot a period o1180 days after the time lhe wo* is conrnenced. $690 5s $0.00 $690.55 lnspector MtD# 2018-142762 $21.2s $665.76 $1.00 $2.54 Fee Tolal: Paid to Date: Balance Oue: Phone: Tenant: Phone: License # Phone: License #: 01 I 16002 51600 01 1 16002 51601 01 1 16002 51612 08901001 24000 BUILDING- INSPECTOR BECORD SITE.WORK DATE ID/SIG COMMENTS Set Backs Forms/Steel/Holdowns UFER Ground SLAB Floor Subf loor/VenVl nsulation Rool Sheathinq 4/2//d.. Shear Wall Framinq lnsu lation/Energy Drywall Ext./lnt. Lath Brown Coat Masonry Pool Fence T-Bar Handicap Req. Deputy Final Report Engineer Final Report Flood Zone Certif a ./--\ FINAL Certilicate of Occu nc Notes, Remarks, Etc 1 rooC Co rrl J I Itt tg 5(/67-) owNl:x Btrll.oF.l Dr:r,( ARAnoN I h.reny lmrm u kr Fnalry of p.rrlry rhd I .fl cr.nli fiom rh. Cdntar"rt Liuc llr ft, tnc tuik,*h8 Erln rsc 70:rl 5 Bulincs{ ,ni Pn)rcsion Conc) Any C y o, Coury shi(h rcqutc\ a Frnnr h c.nsrN.r. !h6. inrn,rc. a.m'lirh .r EI'ri, any drucrun. pri,trr,, irr issuituc. trl\o ftqui..s rh.,mli.r tur ru.h Frfu t,liL: r \i8rcd {ltcnrnl rhul lEor sh. k li.cn*l Pusudnl to rhc l,ortn6\ .1thc Co n.nn ( Liccnrd li* ((lupls 9. Co'n'tuft-in8 *irh Sr.tion TtXXr of Divkion I ol lh. Blsinc* and I,rl,f.rsl'N (ixk)or rhar h.Mrh. r.rn{ir rh.rcfnnn Bnl rh.ha(i< Lr rrr {lk*d.rcq,ri'. AnyvrbriontrrSclr{7oll5bylny .fi'lranr fitr r lE.md \ubr.rr rlE rpplEanr !o !$np.Elrtof mr mrcrhrn firc hundrcd d.lhh rl5txrr _1. d\ nr,kr olh. loFny,,, nry.nrlDlrs rirh *!8.\ r rlr sh (mFnqtirn. *illd' rrr f,,,1ad rhc {tu18 Btr{ '.rcd.n or ollcEd ntr eb l S( Tlg,l. EusirEss ond ttoL*tr,ni Cadc: 't h. (i,nrrrcror's I n e * l re d(,c( nor amly nt rn o*rcr nt rhcpmIany *h' hlild\ or iq,oh\ rl@ ,rrdwh,d,{i\uchn,Ahinx.lforh.r*llorrhn)uIhhi\orhcro*ncn{l.rcc.. nrorilcd rh"r uh invnntftnhern inkrddl., ullinl ft.sL ll h,Nrs ill hoitlinq Dr i'lt,kmnr is v,klwrhrnorc )ttr ofco,rpkr,n. rlr ().mr AtriUd sill h.!r rlr hnLtr olFnrn8 rttsr hc rdxdr,n tlild or iryn,f rh. I'oldy nt tlr llnqr{ of Lr\ow'r nrh.I'nrl{nt.rnr.rlhtrcly.oori(nNtr h l'(rn{d n trr,(rn\ r,' .oniru.r ilr tr,,(r ( Sd rrrs. tlutn}\ irl ln'rs\rr(inlc lhcContrxrntr \l i.cn\c l-us,n).\ norrlnlyt) !trr*tr(r ofprol[n) *h hnrldsorimp(nt\rh.rcotr. nnd sho.onri.t(t)r$.hp,!.(l\wirh!(i!.x.n)(\rlrcrs'1r,tr'\urnrr,rhr(i,ntr.rtr'\l.ircNcLrw) I rmcr.mfl u*lcr Ssli,n rlltf,lBr_r:9Nu;litAlllt! III,(IABATru! I hcrch) rfinnr nn,lcr Jrnrhyol,u|uyonc ofrhc nrll"$nrt d..liruri,tr^ -l h!rc {rl unl m inhin . Ccn irr . ol Conynr h s.lr lniur. tor r.rld ! (,nltnsrion. r{ Pf,n ilcd for by sdrmn tTlr) or rh. Itrhor (in . !,r rrF Fr.),mBr .l 'lE *on lo. f,hrh tlr Fnril i( irsu.n Ih{r.a f,nl trbrntrin r or lcr eoqf,tr\ari'n i.\ur itu.. $ rcq!trlrl hv S$i n h lTllr of rh. I jh C-ftlc- Lt rh. |]( ormmc nl rhc rol ir shrh rhs Firnir r{ N{nt Mysorkcrr $ rt{.s!rt). insonn.. .!ri.r lnd F)l.ynu $d r. I.cnrl, lhrr rnrh.r'erl|ru'{.olrhc*orli(trshf,hrhrFrmi r Furd.I \hJlllmr.onl(') J ) p(^.n inrynrnnrr w, r\ n, h.$nr n'hF.r t! rhL *or\d \ com|tninh.n h* \ ' 't (-rlil nr.,' JtN rhri ifl \lx,ultlti(m \obj..r i'rlt *o cr cr lxn\Dri(n, ptuv'\i,,ii n su i( .17u)olrhr l-nhtr(ix1c.l \hrll. hrrh*i(hco dy $d h rln,$ fhui\i"n\ WARNIN(; I'uilur h c.ur. q,rlcn'conrp.n\tu,tr, .!v.,rsc i\ trih$lxl, tr(l \hnll suhJc.r nrr urPl{Drr ro rnniml ltiDkics rfrl ciril inc\ ut r, .m hutut.J thouu l oll \lSlr[lxxrr 'n ddd n,ni,rri!'\! ,f\' nntr\ n,n. J]ru3c' J. nlo\{lcd i(tr rhc ' ::: - ;/;r7i *' "': ;,, W! , I lltri\tjtt ((J\ lt{,Ac rok DIIiI.ASAIII}N o{ rh( I}uri'k$ n l\.ft\\(r\ (-,xlr. rnl nry lr.n$ N r ltrllnnT r rlk\r y-w'Lty'z 1t r'or ljQllil3llglrol{rEBDllriari[llI I lErbt rmrn uftLr lEMhyof F.llry rhd tlrrc irr co.{Mrion Lndtr3 !3.rf (tr rh. FfomL! of rh. mrk for stih lhi IM $ rskn r*L !1197. Cn Ct kndcrr Nlm APPT I(,TNT DECI TATI(JN I ruLeq mimuRkr pcmh) of Frrnt oft th. n,lL,*rn8lALldarn'nr l)cn,lili'n l'.r,nn\ ArlEdo( N.i'li.!rx,n l:ffltral R.ttrLrirn\ iIdl. Jtl. Ir 6r Roqtrtr.,l l.rrcrolNoiili. r I c.dri! rllrr rhc tcdcrrln!uIrk,tr\ rrsrl,n! x.lr(o\,.trx*rlrr( trfr r't)rlk.'$k h rhis I'of\r _l c.n 'ly rh,i I llr\ c r.:d rh^ rnnl{rrx,n nd {dr thr rh. rh)\. i.b.nurhrn tr .,r(r I n3re t, (,mdt f, irh rll (-rry tnl (i'unry oRliMrc\ xnl Shr. l jr\ rhrins kt t{ rllins c.n<rtur k,n. d hdch} au htrrr. rqKrnrlri\.r olrhF(ir}ridCounr!k'.nh uFntlI rhJrc trrnri(nrd tn'Jiny tu in\Fa Applic.rl or Aa.nl Sltmturc P.mite Em (p.lDl): 'KW Er-4 't/t2y'7 JtA Erection Pads P O rG;tr6r-crlZ 1 {1 (\- 40an F z$ tsIF z s z tEA6 EJ.t HZ \E IABZ l.1 E,z 3rS \= J: 1 I :E- ss f. a- t>10 q 19,t+z l* * E c-\&l* lw t\7 Ub ; $ !(- l- I=lB.h lil "t tr., 7tt--l- --D -t EF fh s: rrl I I I 9essq,n .o}}.^ HiBE: I: ,^-> %HssrEg e{5}Hi *i. s96'F_ 'rt f,q*le B*! oorP'tcNql t'qg B- Jt6r 4s_o -.P'}:E ef;EI\-/ F 6 d too -- t{- HIcc aB ot$fl'u r$lr*l !E +lE F CF FT -l= dl- *€clrP=d"',-<\\Z I I t I *-SNTA NA,tffi Planning & Building Agency 20 Civic Center Plaza Ross Annex Smoke & CO Alarm Affidavit 1r'rSP,02 2Dr 3 CPCIThis document mqy be lound ot. (Please use a black or blue ink ball-point pen) http //www. sa n ta-ana.orq/o bai Project Address i3l1 5, ,P"p/e.,-r At Srrbl Permit Number: Property Owner:-9-4)!/WLl- C o ntra cto r )Co Lice n se #7 State of California requires that smoke and carbon monoxide (CO) alarms are installed in residential bu ildings. California Residential Code (CRC) Section R314.1and R315.2 states in part that existing dwellings be "retrofitted with smoke alarms and carbon monoxide alarms. CRC Section R314.3 and R314.3.3 define the requ ired locations. A so,t boxes below must be checked: I Crrbon monoxide alarms: Are installed outside of each sleeping area in the immediate vicinity of bedrooms and also on each level of the dwelling. Alarms are required in bedrooms with gas-fired appliances (i.e. hot water heater, cooktop, furnace) or a fireplace. psmokgalarms: Are installed in each room used for sleeping, in each hallway outside of a sleeping room, and on each level of the dwelling. Retrofitted detectors may be battery-operated for buildings where no interior alterations are performed. Combination Smoke/CO alarms must comply with all applicable standards and be approved by the State Fire Marshall (SFM). Battery llfe must be 10 years. I hereby certify that I am the contractor or the property owner of the above project. lfurther certify that smoke alarms and carbon monoxide alarms have been installed in compliance with the governing Codes and have been tested to be functional. l, also, hereby certify that lwill retest the alarms per the manufacturer's instructions. (check onel r L,cen sed Co ntractor tr P rope rty wner NOTE: Ihrs sef-c ertification is only used lor projects thdt ofied the EXTERIOR of the structure. This process is applicable ONLY to projects where occess to the interior oI the dwelling by a Sdntd Ano lnspector is not required. LI.*4 l^,L'Ddte:4 /s, /,< Have this completed form and the job-card readily available on final inspectionl P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www. santa-ana.olq I I f ? Signoture: I I I