HomeMy WebLinkAbout1108 3%4 N Harbor Blvd Unit# WCC03 - PlanNOT F O R ONS T R U C T NOT F O R ONS T R U C T NOT F O R ONS T R U C T NOT F O R ONS T R U C T NOT F O R ONS T R U C T r CITY OF SANTA ANA Planning and Building Agency Project #: KHCLE-80917 FA Number. 12844672 Site Name: BUDGET INN HOTEL APPENDIX A ROOFTOP REVIEW SUMMARY FORM ATn MVt6 d FOR PERMIT ISSUANCE Master ID: Date: CITY OF SANTA ANA Planning and Building Agency �d IUANCE 0 s 0 3 0 0 0 v 0� o m s= 0s m N mN m c 3 3 -o m 3 0 � o � N v O �G N � N � C N N O. 3 O. W ID W J O W 3 CITY OF SANTA ANA Planning and Building Agency FA Number: 10086011 Site Name: 1341VINELAND APPENDIX B LOAD COMPARISON RESULTS Project #: KHCLE-79770 Page 2 Anni rnvpd FOR PERMIT ISSUANCE Master ID- Date: CITY OF SANTA ANA Planning and Building Agency Rooftop Loading Comparison PROJECTr r USID 253185 FA Number 12844672 Site Name BUDGET INN HOTEL KH Project # KHCLE-80917 PREVIOUS ANALYSIS Equipment DEAD LOADS (2021DESIGN) I quantity I Unit Weight (Ibs) I Total Weight (Ins) Antenna (Generic) 1 9 1 68 612 DC Unit 1 2 34.9 69.8 Radio (Generic) 1 36 72 2592 Total Appurtenance Weight (Ibs) 3274 + PROPOSED Equipment REMAINING Quantity DEAD LOADS Unit Weight (Ibs) Total Weight (Ibs) RRUS-8843 62/1366A 3 75 225 RRUS-4449 65/612 3 73 219 RRUS-4478 B14 3 59.4 178.2 RRUS-E2 B29 3 52.9 158.7 RRUS-4415 B30 3 47.4 142.2 DC Unit 3 34.9 104.7 Commscope NNH4-65A-R6H4 3 86.5 259.5 Ericsson AIR6472 B77G/B77M 3 67.1 201.3 Quintel QS4658-3E 3 67.9 203.7 Quintel4658-7 3 68 204 Total Appurtenance Weight (Ibs) 1896 Proposed Equipment SUMMARY DEAD LOAD Previous SA Dead Load 3274 Proposed+Existing Dead Load 1896 Percent Increase 1 -42.1% Note: Equipment is fully shielded by existing concealment structure; therefore, there is negligible change in lateral wind loading. Seismic loading directly correlates to dead load; therefore, there is a similar percent increase in lateral and vertical seismic loading. Kiml Approved OW*n ISSUANCE Master ID: Date: Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N T-1 EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS TITLE SHEET SITE NUMBER: CLL01585 SITE NAME: BUDGET INN HOTEL FA#: 12844672 USID#: 253185 SHEET INDEX APPROVALS AERIAL VIEWVICINITY MAP DRIVING DIRECTIONS SITE INFORMATION CODE COMPLIANCE PROJECT TEAM GENERAL NOTES PROJECT DESCRIPTION AT&T RF ENGINEER: SAQ MANAGER: PROJECT MANAGER: ZONING VENDOR: LEASING VENDOR: ZONING MANAGER: PROPERTY OWNER: APPROVED BY:DATE: AT&T OPERATIONS: THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS & AUTHORIZE THE SUBCONTRACTOR TO PROCEED WITH THE ZONING DESCRIBED HEREIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT & MAY IMPOSE CHANGES OR MODIFICATIONS. AT&T WIRELESS PROPOSES TO INSTALL A WIRELESS COMMUNICATIONS FACILITY. THE SCOPE WILL CONSIST OF THE FOLLOWING: UNDERGROUND SERVICE ALERT UTILITY NOTIFICATION CENTER OF CALIFORNIA (800) 422-4133 WWW.CALIFORNIA811.ORG CALL 2-14 WORKING DAYS UTILITY NOTIFICATION PRIOR TO CONSTRUCTION THIS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. A TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE. NO SANITARY SEWER SERVICE, POTABLE WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS NEW. IF CONTRACTOR ENCOUNTERS CONDITIONS IN FIELD, EITHER UNFORESEEN OR IN SOME MANNER IN CONFLICT WITH THESE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE REGISTERED DESIGN PROFESSIONAL OF SUCH CONDITIONS IN WRITING AND SHALL ACKNOWLEDGE ANY WORK DONE OUTSIDE OF JURISDICTIONAL PERMITTED PLANS IS DONE AT CONTRACTORS OWN RISK. FOR "SPECIAL INSPECTIONS" SPECIFIC TO THIS PROJECT PURSUANT TO CBC SECTION 1704.3, SEE SHEET T-4, "STATEMENT OF SPECIAL INSPECTIONS" SUBCONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. FULL SIZE = 24”x36”. ANY OTHER SIZE PRINT IS NOT ORIGINAL SCALE. ALL INDICATED DIMENSIONS SHALL TAKE PRECEDENT OVER SCALED DIMENSIONS. SITE SITE PROJECT MANAGER: EUKON GROUP 65 POST, SUITE 1000 IRVINE, CA 92618 CONTACT: AUSTIN PAPPAS PHONE: (949) 292-4312 EMAIL: austin@eukongroup.com RF ENGINEER: SITE ACQUISITION: ZONING: EUKON GROUP 65 POST, SUITE 1000 IRVINE, CA 92618 CONTACT: JERRY AMBROSE PHONE: (805) 637-7407 EMAIL: jambrose@wireless01.com A&E CONTACT: CONSTRUCTION: ·FIELD VERIFY AZIMUTHS AND ENSURE THE ANTENNAS ARE SHOOTING THE DESIGNED AZIMUTHS ·REMOVE (3) EXISTING AIR6449 B77D ·INSTALL (3) AIR6472 DB CBAND /DOD B77G/B77M ·REPLUMB (3) 8843 B2/B66A RRH TO POS1/POS3 ·REPLUMB (3) 4478 B14 RRH TO POS3/POS4 ·REUSE (3) EXISTING DC9, (9) POWER TRUNKS, (3) FIBER TRUNKS ·REUSE (1) EXISTING NETSURE 7100 INDOOR POWER PLANT W/-58 ·INSTALL (4) C48/58 -2000P3 ·REUSE (12) EXISTING R48-2000e3 ·REUSE (28) EXISTING SBS170F ·REUSE (3) EXISTING 50A BREAKERS ·REMOVE ALL MDT BRACKETS ADDRESS: TELEPHONE COMPANY:- POWER COMPANY:- CONSTRUCTION TYPE:I-B OCCUPANCY GROUP:R-1 PARCEL NUMBER:198-011-05 ZONING DISTRICT:SP2 ZONING JURISDICTION:CITY OF SANTA ANA LONGITUDE (NAD 83):117° 55' 13.929" W LATITUDE (NAD 83): 33.754653° COUNTY:ORANGE COUNTY PROPERTY OWNER:NORTH HARBOR 1.HEAD SOUTHEAST ON INDUSTRIAL DR. THEN 0.09 MI 2.TURN LEFT ONTO RED HILL AVE. THEN 0.1 MI 3.TURN LEFT ONTO EDINGER AVE. THEN 0.5 MI 4.TURN LEFT ONTO NEWPORT AVE. THEN 0.3 MI 5.TURN RIGHT AND TAKE RAMP ONTO CA-55 N (COSTA MESA FWY). THEN 0.9 MI 6.TAKE EXIT 10B TOWARD SANTA ANA ONTO I-5 N (SANTA ANA FWY). THEN 3.7 MI 7.TAKE EXIT 106 TOWARD LONG BEACH ONTO CA-22 W (GARDEN GROVE FWY). THEN 3.0 MI 8.TAKE EXIT 12 TOWARD HARBOR BLVD. THEN 0.3 MI 9.TURN LEFT ONTO HARBOR BLVD. THEN 1.0 MI 10.TURN RIGHT.THEN 0.06 MI 11.1108 N HARBOR BLVD SANTA ANA, CALIFORNIA 92703-1619 DIRECTIONS FROM AT&T OFFICE AT 1452 EDINGER AVE, TUSTIN, CA 92780 ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, AND IS EXEMPTED FROM ACCESSIBILITY REQUIREMENTS IN ACCORDANCE WITH 2022 CALIFORNIA BUILDING CODE SECTION 11B-203.5. THIS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. A TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE. NO SANITARY SEWER SERVICE, POTABLE WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS NEW. 1.2022 CALIFORNIA ADMINISTRATIVE CODE 2.2022 CALIFORNIA BUILDING CODE 3.2022 CALIFORNIA ELECTRIC CODE 4.2022 CALIFORNIA MECHANICAL CODE 5.2022 CALIFORNIA PLUMBING CODE 6.2022 CALIFORNIA FIRE CODE 7.ANY LOCAL BUILDING CODE AMENDMENTS 8.CITY/COUNTY ORDINANCES 9.ANSI / TIA-222 STRUCTURAL CODE 10.NFPA 780 - LIGHTING PROTECTION CODE SITE TYPE: ROOFTOP SITE ADDRESS: 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 PRIMARY #: WSLOS0068836 SHEET DESCRIPTION T-1 TITLE SHEET A-2 EXISTING AND NEW EQUIPMENT PLAN A-3 EXISTING AND NEW ANTENNA PLAN A-4 A-5 EXISTING AND NEW SOUTH ELEVATIONS A-1.1 ENLARGED SITE PLAN A-1 SITE PLAN REV A A A A A A A T-2 GENERAL NOTES, LEGEND, AND ABBREVIATIONS A T-3 GENERAL SIGNAGE A EQUIPMENT DETAILS A A-4.1 A-3.1 EXISTING AND NEW RRU AND ANTENNA SCHEDULE A 1770 COWAN AVE., STE. 200 -117.920536° 33° 45' 16.7502" N EXISTING AND NEW EAST ELEVATIONS IRVINE, CA 92614 EUKON GROUP 65 POST, SUITE 1000 IRVINE, CA 92618 CONTACT: JERRY AMBROSE PHONE: (805) 637-7407 EMAIL: jambrose@wireless01.com JARED BROOKCONTACT: AT&T 1452 EDINGER AVE, 3RD FLOOR TUSTIN, CA 92780 CONTACT: SANDEEP MANGAT PHONE: (530) 540-4201 EMAIL: sm2840@att.com AT&T 1452 EDINGER AVE, 3RD FLOOR TUSTIN, CA 92780 CONTACT: DAVID TOVLIN PHONE: (562) 243-5168 EMAIL: dt2777@att.com EUKON GROUP 65 POST, SUITE 1000 IRVINE, CA 92618 CONTACT: FRANCISCO ESPINOZA PHONE: (949) 577-3953 EMAIL: francisco.espinoza@eukongroup.com AGN-1 DC POWER DIAGRAM / EQUIPMENT & ANTENNA GROUNDING AGN-2 GROUNDING DETAILS HOUSING PARTNERS LP NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N T-2 EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS ABBREVIATIONS GENERAL NOTES, LEGEND, AND ABBREVIATIONS GENERAL NOTES 15 1.THE FACILITY IS AN UNOCCUPIED DIGITAL TELECOMMUNICATION FACILITY. 2.PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 3.PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION ENGINEER AND ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 4.THE CONTRACTOR SHALL OBTAIN, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 5.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 6.ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 7.THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE IMPLEMENTATION ENGINEER AND WITH THE LANDLORD'S AUTHORIZED REPRESENTATIVE. 8.SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH U.L. LISTED AND FIRE CODE APPROVED MATERIALS. 9.PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING CONSTRUCTION. 10.DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 11.REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY DRAWING (SHEET LS1 OR SHEET C-1), SHALL NOT BE USED TO IDENTIFY OR ESTABLISH THE BEARING OF TRUE NORTH AT THE SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANY SURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL NOTIFY THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THE TRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO NOTIFY THE ENGINEER. 12.THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, VEGETATION, GALVANIZED SURFACES, ETC., AND UPON COMPLETION OF WORK REPAIR ANY DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF AT&T. 13.KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY NATURE. 14.PENETRATIONS OF ROOF MEMBRANES SHALL BE PATCHED/FLASHED AND MADE WATERTIGHT USING LIKE MATERIALS IN ACCORDANCE WITH NRCA ROOFING STANDARDS AND DETAILS. CONTRACTOR SHALL OBTAIN DETAILING CLARIFICATION FOR SITE-SPECIFIC CONDITIONS FROM ENGINEER, IF NECESSARY, BEFORE PROCEEDING. 15.BEFORE ORDERING AND/OR BEFORE FABRICATING/CONSTRUCTING/INSTALLING ANY ITEMS, VERIFY THE TYPES AND QUANTITIES. 16.CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE AND PAGER, AND KEEP SAME ON SITE WHENEVER PERSONNEL ARE ON SITE. 17.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON THE SITE AND NOTIFY THE PROJECT MANAGER OF ANY DISCREPANCIES BEFORE STARTING ANY WORK. 18.CONTRACTOR TO PROVIDE COMPLETE SET OF AS BUILT DRAWINGS WITHIN 10 WORKING DAYS OF PROJECT COMPLETION. 19.CONTRACTOR IS TO EXCAVATE 6" BELOW EXISTING GRADE AND SPRAY WITH WEED CONTROL. REPLACE WITH CLASS II AGGREGATE BASE AND CRUSHED WASHED ROCK. AS SPECIFIED ON SITE PLAN. 20.CONTRACTOR SHALL PROVIDE TOILET FACILITY DURING ALL PHASES OF CONSTRUCTION. 21.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION OR THE FABRICATION OF MATERIALS TO BE INSTALLED AT THE SITE, THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS INCLUDING AS-BUILT DIMENSIONS OF EXISTING STRUCTURES OR STRUCTURAL ELEMENTS HAVING A BEARING ON THE SCOPE OF THE WORK TO BE PERFORMED. IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THE DIMENSIONS OR CONDITIONS FOUND TO BE EXISTING IN THE FIELD, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND OBTAIN DESIGN RESOLUTION PRIOR TO PROCEEDING WITH THE PORTION(S) OF THE WORK AFFECTED. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO SO NOTIFY THE ENGINEER AND OBTAIN RESOLUTION BEFORE PROCEEDING. NOTES FOR EXISTING AT&T CELL SITES: 1.PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. 2.SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 3.THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK BY SUBCONTRACTOR SHALL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY WORK ON EXISTING EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK SHOULD BE SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS AFTER MIDNIGHT. 4.SINCE THE CELL SITE IS ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL RF EXPOSURE MONITORS ARE ADVISED TO BE WORN TO ALERT OF ANY DANGEROUS EXPOSURE LEVELS. 5.SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. SUBCONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS NECESSARY. SUBCONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. 6.SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. LEGEND 7 - - - - A AMPERE A&E ARCHITECTURE AND ENGINEERING A.B. ANCHOR BOLT ABV. ABOVE AC ALTERNATE CURRENT/AIR CONDITIONER ACCA ANTENNA CABLE COVER ASSEMBLY ADD'L ADDITIONAL A.F.F. ABOVE FINISHED FLOOR A.F.G. ABOVE FINISHED GRADE AIC AMPERE INTERRUPTING CAPACITY ALUM. ALUMINUM ALT. ALTERNATE ANT. ANTENNA APPR0X. APPROXIMATE(LY) ARCH. ARCHITECT(URAL) AT. AMPERE TRIP AWG. AMERICAN WIRE GAUGE BATT. BATTERY BD. BOARD BLDG. BUILDING BLK. BLOCK BLKG. BLOCKING BM. BEAM B.N. BOUNDARY NAILING BR. BRANCH BRKR. BREAKER BTCW. BARE TINNED COPPER WIRE BTS. BASE TRANSMISSION SYSTEM B.O.F. BOTTOM OF FOOTING B/U BACK-UP CABINET C CONDUIT CAB. CABINET CANT. CANTILEVER(ED) CB. CIRCUIT BREAKER CDMA CODE-DIVISION MULTIPLE ACCESS CDUK CONSOLIDATION DISTRIBUTION UNIT KIT C.I.P. CAST IN PLACE CKT. CIRCUIT C CENTERLINE CLG. CEILING CLR. CLEAR CMU CONCRETE MASONRY UNIT COL. COLUMN CONC. CONCRETE CONN. CONNECTION(OR) CONST. CONSTRUCTION CONT. CONTINUOUS d PENNY (NAILS) DBL. DOUBLE DC DIRECT CURRENT DEM. DEMAND DEPT. DEPARTMENT D.F. DOUGLAS FIR DIA. DIAMETER DIAG. DIAGONAL DIM. DIMENSION DO DITO (THE SAME) DWG. DRAWING(S) DWL. DOWEL(S) (E)EXISTING EA. EACH EGR. EMERGENCY GENERATOR RECEPTACLE EL. ELEVATION ELEC. ELECTRICAL ELEV. ELEVATOR EMT. ELECTRICAL METALLIC TUBING E.N. EDGE NAIL ENCL. ENCLOSURE ENG. ENGINEER EQ. EQUAL ESR EVALUATION SERVICE REPORT EXP. EXPANSION EXT. EXTERIOR FAB. FABRICATION(OR) FAC. FACTOR F/A FIRE ALARM F.F. FINISH FLOOR F.G. FINISH GRADE F.J. FLOOR JOIST FIN. FINISH(ED) FLR. FLOOR FLUOR FLUORESCENT FDN. FOUNDATION F.O.C. FACE OF CONCRETE F.O.M. FACE OF MASONRY F.O.S. FACE OF STUD F.O.W. FACE OF WALL FRP FIBER REINFORCE POLYMER F.S. FINISH SURFACE FT.(') FOOT (FEET) FTG. FOOTING FU FUSE G GROUND GR GROWTH (CABINET) GA. GAUGE GALV. GALVANIZE(D) GEN. GENERATOR G.F.C.I. GROUND FAULT CIRCUIT INTERRUPTER GLB. (GLU-LAM) GLUE LAMINATED BEAM GND GROUND GPS GLOBAL POSITIONING SYSTEM GRND. GROUND GSM GLOBAL SYSTEM MOBILE HDBC HARD DRAWN COPPER WIRE HDR. HEADER HGR. HANGER HPS HIGH PRESSURE SODIUM HT. HEIGHT ICC INTERNATIONAL CODE COUNCIL ICGB. ISOLATED COPPER GROUND BUS ILC INTEGRATED LEAD CENTER IN.(") INCH(ES) INT. INTERIOR L.LONG(ITUDINAL) LARR LOS ANGELES RESEARCH REPORT LB.(#) POUND(S) L.B. LAG BOLTS L.F. LINEAR FEET (FOOT) LG. LENGTH LPS LOW PRESSURE SODIUM LTE LONG TERM EVOLUTION MAS. MASONRY MAX. MAXIMUM M.B. MACHINE BOLT MECH. MECHANICAL MFR. MANUFACTURER MIN. MINIMUM MISC. MISCELLANEOUS MLO MAIN LUGS ONLY MTD. MOUNTED MTG. MOUNTING MTL. METAL MTS. MANUAL TRANSFER SWITCH N NEUTRAL (N) NEW NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOC. NO.(#) NUMBER N.T.S. NOT TO SCALE OBIF OPTICAL BASEBAND INTERFACE OH OVERHEAD O.C. ON CENTER OPNG. OPENING (P)PROPOSED P POLE P/C PRECAST CONCRETE PCS PERSONAL COMMUNICATION SERVICES PH PHASE PLY. PLYWOOD PNLBD PANELBOARD PPC POWER PROTECTION CABINET PRC PRIMARY RADIO CABINET L.PROPERTY OR PROPERTY LINE PRI PRIMARY P.S.F. POUNDS PER SQUARE FOOT P.S.I. POUNDS PER SQUARE INCH P.T. PRESSURE TREATED P.T.D.F. PRESSURE TREATED DOUGLAS FUR PWR. POWER QTY. QUANTITY RAD.RADIATION R RADIUS RBS RADIO BASE STATION RCPT. RECEPTACLE REF. REFERENCE REINF. REINFORCEMENT(ING) REQ'D. REQUIRED RF RADIO FREQUENCY RGS. RIGID GALVANIZED STEEL R.J. ROOF JOIST R.R. ROOF RAFTER RRU REMOTE RADIO UNIT (RADIO TRANSCEIVER) RX-AIT RECEIVER AIR INTERFACE TRAY SAF SAFETY SAQ SITE ACQUISITION SCH. SCHEDULE SDBC SOFT DRAWN BARE COPPER SEC SECONDARY SHT. SHEET SIM. SIMILAR S.N. SOLID NEUTRAL SPEC. SPECIFICATION(S) SQ. SQUARE S.S. STAINLESS STEEL STD. STANDARD STL. STEEL STRUC. STRUCTURAL SURF SURFACE SW SWITCH TEL. TELEPHONE TEMP. TEMPORARY THK. THICK(NESS) TMA TOWER MOUNTED AMPLIFIER (DC SUPPLY VOLTAGE) T.N. TOE NAIL T.O.A. TOP OF ANTENNA T.O.C. TOP OF CURB T.O.F. TOP OF FOUNDATION T.O.P. TOP OF PLATE OR PARAPET T.O.R.TOP OF ROOF T.O.S. TOP OF STEEL T.O.W. TOP OF WALL TYP. TYPICAL U.G. UNDER GROUND U.L. UNDERWRITERS LABORATORY INC. UMTS UNIVERSAL MOBIL TECH. SYS. U.N.O. UNLESS NOTED OTHERWISE V VOLT VAC VOLT ALTERNATING CURRENT V.I.F. VERIFY IN FIELD W WATT OR WIRE WD WIDE(WIDTH) W/ WITH W/O WITHOUT WD. WOOD W.P. WEATHERPROOF WT. WEIGHT XFER TRANSFER XFMR TRANSFORMER XLPE CROSS-LINK POLYETHYLENE 1 1 L PROPERTY LINE / LEASE AREA NEW POWER CABLE NEW FIBER CABLE NEW POWER AND FIBER CABLES NEW HYBRID CABLES OVERHEAD POWER CABLES OVERHEAD COMMUNICATIONS CABLES EXISTING POWER CABLES EXISTING COMMUNICATION CABLES EXISTING WATER PIPES EXISTING SEWER PIPES EXISTING STORM DRAIN PIPES EXISTING GAS PIPES EXISTING GASOLINE PIPES CHAIN-LINK FENCING GROUTED OR PLASTER BRICK MASONRY CONCRETE STEEL EARTH GRAVEL PLYWOOD SAND WOOD CONTINUOUS WOOD BLOCKING SPOT ELEVATION REVISION GRID REFERENCE ELECTRICAL BOX TELEPHONE BOX ELECTRICAL METER SAFETY SWITCH (DISCONNECT) AUTOMATIC TRANSFER SWITCH CIRCUIT BREAKER ELECTRICAL SWITCH SMOKE DETECTOR TRANSFORMER UTILITY POLE POLE MOUNTED XFMR PAD MOUNTED XFMR DETAIL REFERENCE ELEVATION REFERENCE SECTION REFERENCE PWR FBR OHP OHT E T W S SD G GS X CENTER LINE E T M - - NEW COAX CABLES S S P/F HYBD COAX GROUND ROD GROUND ROD WITH INSPECTION/TEST WELL EXOTHERMIC GROUND CONNECTION COMPRESSION GROUND CONNECTION CHEMICAL ELECTROLYTIC GROUNDING GROUNDING CONDUCTOR GROUND BAR NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N T-3 EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS AT&T REQUIRED SIGNAGE GENERAL SIGNAGE 1 GENERATOR BATTERY NO SCALE 3 2 W 2 BATTERY NO SCALE 3 0 W 2 CAUTION SIGNS NO SCALE INFO SIGN #5 NO SCALE CAUTION SIGN NO SCALE INFO SIGN #3 NO SCALE INFO SIGN #2 NO SCALE INFO SIGN #4 NO SCALE INFO SIGN #1 NO SCALE STRUCTURE TYPE DIESEL NO SCALE 0 2 0 0 SIGNAGE GUIDELINES CHART GENERAL SIGNAGE GUIDELINES INFO SIGN #1 INFO SIGN #2 INFO SIGN #3 INFO SIGN #4 INFO SIGN #5 STRIPING NOTICE SIGN CAUTION SIGN TOWERS MONOPOLE / MONOPINE / MONOPALM / FAUX EUCALYPTUS / BROADLEAF SCE TOWERS / TOWERS WITH HIGH VOLTAGE LIGHT POLES / FLAG POLES UTILITY WOOD POLES (JPA) MICROCELLS MOUNTED ON NON-JPA POLES ROOFTOPS AT ALL ACCESS POINTS TO THE ROOF ON ANTENNAS CONCEALED ANTENNAS ANTENNAS MOUNTED FACING OUTSIDE THE BUILDING ANTENNAS ON SUPPORT STRUCTURE ROOF VIEW GRAPH: RADIATION AREA IS WITHIN 3FT FROM ANTENNA RADIATION AREA IS BEYOND 3FT FROM ANTENNA CHURCH STEEPLES WATER TOWERS NOTES FOR ROOFTOP SITES: 1. EITHER NOTICE OR CAUTION SIGNS NEED TO BE POSTED AT EACH SECTOR AS CLOSE AS POSSIBLE TO: THE OUTER EDGE OF THE STRIPED OFF AREA OF THE OUTER ANTENNAS OF THE SECTOR. 2. IF ROOFVIEW SHOWS: ONLY BLUE = NOTICE SIGN, BLUE AND YELLOW = CAUTION SIGN, ONLY YELLOW = CAUTION SIGN TO BE INSTALLED. 3. SHOULD THE REQUIRED STRIPING AREA INTERFERE WITH ANY STRUCTURES OR EQUIPMENT (A/C, VENTS, ROOF HATCH, DOORS, OTHER ANTENNAS, DISHES, ETC.). PLEASE NOTIFY AT&T TO MODIFY THE STRIPING AREA, PRIOR TO STARTING THE WORK. ENTRANCE GATES, SHELTER DOORS OR ON THE OUTDOOR CABINETS ON THE POLE, NO LESS THAN 3FT BELOW THE ANTENNA AND NO ON BACKSIDE OF ANTENNAS ON THE SIDE OF ANTENNAS ON THE SHELTER DOOR OR ON ONE OUTDOOR EQUIPMENT CABINET ---- AT THE HEIGHT OF THE FIRST CLIMBING STEP, MIN. 9FT ABOVE GROUND ENTRANCE GATES, SHELTER DOORS OR ON THE OUTDOOR CABINETS ON THE POLE, NO LESS THAN 3FT BELOW THE ANTENNA AND NO ON BACKSIDE OF ANTENNAS ON THE SIDE OF ANTENNAS ON THE SHELTER DOOR OR ON ONE OUTDOOR EQUIPMENT CABINET ---- AT THE HEIGHT OF THE FIRST CLIMBING STEP, MIN. 9FT ABOVE GROUND ENTRANCE GATES, SHELTER DOORS OR ON THE OUTDOOR CABINETS ON THE POLE, NO LESS THAN 3FT BELOW THE ANTENNA AND NO ON BACKSIDE OF ANTENNAS ON THE SIDE OF ANTENNAS ON THE SHELTER DOOR OR ON ONE OUTDOOR EQUIPMENT CABINET ------ ENTRANCE GATES, SHELTER DOORS OR ON THE OUTDOOR CABINETS ON THE POLE, NO LESS THAN 3FT BELOW THE ANTENNA AND NO ON BACKSIDE OF ANTENNAS ON THE SIDE OF ANTENNAS ON THE SHELTER DOOR OR ON ONE OUTDOOR EQUIPMENT CABINET -- IF GP MAX VALUE OF MPE AT ANTENNA LEVEL IS: 0-99%: NOTICE SIGN; OVER 99%: CAUTION SIGN AT NO LESS THAT 3FT BELOW ANTENNA AND 9FT ABOVE GROUND ENTRANCE GATES, SHELTER DOORS OR ON THE OUTDOOR CABINETS ON THE POLE, NO LESS THAN 3FT BELOW THE ANTENNA AND NO ON BACKSIDE OF ANTENNAS ON THE SIDE OF ANTENNAS ON THE SHELTER DOOR OR ON ONE OUTDOOR EQUIPMENT CABINET DIAGONAL, YELLOW STRIPING AS TO ROOF VIEW GRAPH NOTICE OR CAUTION SIGN AT NO LESS THAN 9FT ABOVE GROUND: ONLY IF THE EXPOSURE EXCEEDS 90% OF THE GENERAL PUBLIC EXPOSURE AT 6FT ABOVE GROUND X X X X X X X X X X X X EITHER NOTICE OR CAUTION SIGN (BASED ON ROOFVIEW RESULTS) AT ANTENNAS/BARRIER ADJACENT TO EACH ANTENNA ADJACENT TO EACH ANTENNA ACCESS TO STEEPLE ADJACENT TO ANTENNAS IF ANTENNAS ARE CONCEALED ON BACKSIDE OF ANTENNAS ON THE SIDE OF ANTENNAS ON THE SHELTER DOOR OR ON ONE OUTDOOR EQUIPMENT CABINET ----Caution sign at the antennas ACCESS TO LADDER ADJACENT TO ANTENNAS IF ANTENNAS ARE CONCEALED ON BACKSIDE OF ANTENNAS ON THE SIDE OF ANTENNAS ON THE SHELTER DOOR OR ON ONE OUTDOOR EQUIPMENT CABINET ---- Caution sign beside info sign #1, min. 9ft above ground NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N A-1 EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS SITE PLAN SCALE 120'60'30'030'15' 1"=30'-0"1 90° 135 ° 45° 270° 225 ° 180° 315 ° 0° NOTES: 1.IF DIMENSIONS SHOWN ON PLAN DO NOT SCALE CORRECTLY, CHECK FOR REDUCTION OR ENLARGEMENT FROM ORIGINAL PLANS. 2.CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 3.UTILITY DESIGNS AND ROUTES ARE PRELIMINARY PENDING FINAL DESIGN BY UTILITY PROVIDER. 4.THIS SITE PLAN IS NOT INTENDED TO BE A LAND SURVEY. SITE PLAN EXISTING SLAB BOX #P5341663 ~EXISTING SCE EASEMENT~ ~EXISTING PARKING~ ~EXISTING SCE EASEMENT~ SE C T O R " A " AZ I M U T H : 1 5 ° HA R B O R B L V D . CL PR O P E R T Y L I N E PR O P E R T Y L I N E PROPERTY LINE ~EXISTING BUILDING~ SE C T O R " B " AZ I M U T H : 1 7 0 ° SECTOR "C " AZIMUTH: 2 8 0 ° ~EXISTING BUILDING~~EXISTING BUILDING~ SEE ENLARGED SITE PLAN 1 A-1.1 NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N A-1.1 EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS ENLARGED SITE PLAN 32'16'8'4'08'SCALE 3/32"=1'-0"1 90° 135 ° 45° 270° 225 ° 180° 315 ° 0° NOTES: 1.IF DIMENSIONS SHOWN ON PLAN DO NOT SCALE CORRECTLY, CHECK FOR REDUCTION OR ENLARGEMENT FROM ORIGINAL PLANS. 2.CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 3.THIS SITE PLAN IS NOT INTENDED TO BE A LAND SURVEY. ENLARGED SITE PLAN EXISTING AT&T EQUIPMENT LEASE AREA SEE EQUIPMENT PLAN 1,2 A-2 SE C T O R " A " AZ I M U T H : 1 5 ° SE C T O R " B " AZ I M U T H : 1 7 0 ° SECTOR "C " AZIMUTH: 2 8 0 ° HA R B O R B L V D . CL EXISTING SLAB BOX #P5341663 ~EXISTING PARKING~ PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E ~EXISTING SCE EASEMENT~ EXISTING AT&T ANTENNA AREA SEE ANTENNA PLAN 1,2 A-3 EXISTING AT&T ANTENNA AREA SEE ANTENNA PLAN 1,2 A-3 NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N A-2 EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS SCALE 16'8'4'04'2' 1/4"=1'-0"2 NOTE: 1.IF DIMENSIONS SHOWN ON PLAN DO NOT SCALE CORRECTLY, CHECK FOR REDUCTION OR ENLARGEMENT FROM ORIGINAL PLANS. 2.CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. EXISTING AND NEW EQUIPMENT PLAN EXISTING EQUIPMENT PLAN 90° 135 ° 45° 270° 225 ° 180° 315 ° 0° EXISTING AC UNITS, 2-TYP. EXISTING CABLE TRAY 12 ' - 0 " EX I S T I N G A T & T L E A S E A R E A ~STORAGE UNIT~ ~STORAGE UNIT~ ~HALLWAY~ EXISTING TELCO BOARD EXISTING AC PANEL 16'-0" EXISTING AT&T LEASE AREA EXISTING NETSURE 7100 SYSTEM 1000A DCPP EQUIPPED WITH (12) EXISTING POWERSAFE BATTERY SBS170F, (12) R48-2000e3 RECTIFIERS ~UTILITY ROOM~ EXISTING VDC BATTERY RACK WITH (16) SBS170F (2023) BATTERIES EXISTING AC UNITS, 2-TYP. EXISTING CABLE TRAY 12 ' - 0 " EX I S T I N G A T & T L E A S E A R E A ~STORAGE UNIT~ ~STORAGE UNIT~ ~HALLWAY~ EXISTING TELCO BOARD EXISTING AC PANEL 16'-0" EXISTING AT&T LEASE AREA EXISTING RACK WITH (3) 50A BREAKERS, (3) DC12-48-60-RM, (2) 6630, (1) 6648, (1) 6601, (1) XMU, FLEXI HAUL HSN8300NA EXISTING NETSURE 7100 SYSTEM 1000A DCPP EQUIPPED WITH (12) EXISTING POWERSAFE BATTERY SBS170F, (12) R48-2000e3 RECTIFIERS INSTALL (4) C48/58-2000P3 ~UTILITY ROOM~ EXISTING VDC BATTERY RACK WITH (16) SBS170F (2023) BATTERIES 90° 135 ° 45° 270° 225 ° 180° 315 ° 0° SCALE 16'8'4'04'2' 1/4"=1'-0"1NEW EQUIPMENT PLAN EXISTING RACK WITH (3) 50A BREAKERS, (3) DC12-48-60-RM, (2) 6630, (1) 6648, (1) 6601, (1) XMU, FLEXI HAUL HSN8300NA NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N A-3 EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS 90° 135 ° 45° 270° 225 ° 180° 315 ° 0° NOTE: 1.IF DIMENSIONS SHOWN ON PLAN DO NOT SCALE CORRECTLY, CHECK FOR REDUCTION OR ENLARGEMENT FROM ORIGINAL PLANS. 2.CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 3.ANTENNA AND MW AT&T SPECIFICATIONS REFER TO ANTENNA SCHEDULE AND TO FINAL CONSTRUCTION RFDS FOR ALL RF DETAILS. EXISTING ANTENNA PLAN 4'2'1'6"01'SCALE 3/4"=1'-0"1NEW ANTENNA PLAN EXISTING AND NEW ANTENNA PLAN 90° 135 ° 45° 270° 225 ° 180° 315 ° 0° 4'2'1'6"01'SCALE 3/4"=1'-0"2 C1 SE C T O R " A " AZ I M U T H : 1 5 ° SE C T O R " B " AZ I M U T H : 1 7 0 ° SECTOR "C " AZIMUTH: 2 8 0 ° C2 C3 B1 B2 B3 A3 A2 A1 EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) EXISTING DC-9 SURGE SUPPRESSOR (3 TOTAL) EXISTING PANEL ANTENNAS (3 PER SECTOR, 9 TOTAL) EXISTING AT&T AIR6449 N77D ANTENNA (TYP.-1 PER SECTOR, 3 TOTAL) TO BE REMOVE EXISTING GPS ANTENNA EXISTING 2" Ø MW ANTENNA, 2 TYP. EXISTING CABLE TRAY EXISTING PIM RF BARRIER ADHERED TO PARAPET, TYP. EXISTING FRP SCREEN WALL LOUVER TO RESEMBLE METAL FINISH 2'-8" 19'-6" EXISTING FRP SCREEN 18 ' - 1 0 " EX I S T I N G F R P S C R E E N 19'-11" EXISTING FRP SCREEN C1 SE C T O R " A " AZ I M U T H : 1 5 ° SE C T O R " B " AZ I M U T H : 1 7 0 ° SECTOR "C " AZIMUTH: 2 8 0 ° C2 C3 B1 B2 B3 A3 A2 A1 EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) RRU 4478-B14 RELOCATED TO A3, A4 EXISTING DC-9 SURGE SUPPRESSOR (3 TOTAL) EXISTING PANEL ANTENNAS (3 PER SECTOR, 9 TOTAL) EXISTING GPS ANTENNA EXISTING 2" Ø MW ANTENNA, 2 TYP. EXISTING CABLE TRAY EXISTING PIM RF BARRIER ADHERED TO PARAPET, TYP. EXISTING FRP SCREEN WALL LOUVER TO RESEMBLE METAL FINISH 19'-6" EXISTING FRP SCREEN 18 ' - 1 0 " EX I S T I N G F R P S C R E E N 19'-10" EXISTING FRP SCREEN EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) RRU 4478-B14 RELOCATED TO B3, B4 EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) RRU 4478-B14 RELOCATED TO C3, C4 1,2 A-5 NEW AIR6472 B77G/B77M ANTENNAS (1 PER SECTOR, 3 TOTAL) A4 3'-0"3'-0"3'-0" 3'-0"3'-0"3'-0" 3' - 0 " 3' - 0 " 3' - 0 " B4 C4 6'-0"6'-0" 6'-0"6'-0" 6' - 0 " 6' - 0 " NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N A-3.1 EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS EXISTING AND NEW RRU AND ANTENNA SCHEDULE SCALE NONE 1 EXISTING AND NEW RRU AND ANTENNA SCHEDULE COAX - AL P H A SE C T O R A1 SECTOR A2 A3 A4 SIZE COUNT - FIBER - - SIZE COUNT 1 - - POWER 6 - - SIZE COUNT 3 - - RET - - - SIZE COUNT - - - MICROWAVE - - SIZE COUNT - - BE T A SE C T O R B1 B2 B3 B4 C1 C2 C3 C4 0 12 TOTAL CABLE COUNT 3 0 09 EXISTING CABLE COUNT LENGTH - GA M M A SE C T O R ------ ---- -- - ---- ---- ----- ----- COAX AL P H A SE C T O R A1 SECTOR A2 A3 A4 SIZE COUNT FIBER SIZE COUNT POWER SIZE COUNT RET SIZE COUNT MICROWAVE SIZE COUNT BE T A SE C T O R B1 B2 B3 B4 C1 C2 C3 C4 TOTAL CABLE COUNT FINAL CABLE COUNT LENGTH GA M M A SE C T O R -- ---- ---- ----- ----- SECTOR A1 RF DATA SCHEDULE @ TOWER A2 AL P H A SE C T O R QTY. REMOTE RADIO UNIT (RRUS) 1 1 MICROWAVE DISH (E) MODEL SIZE ANTENNA A3 A4 FINAL MODEL(E) MODEL QTY. -INTEGRATED QTY. N/A (E) MODEL N/A SIZE N/A QTY.FINAL MODELSIZE (E) TECHNOLOGY FINAL TECHNOLOGYQTY.(E) AZIMUTH 15° FINAL AZIMUTH (E) RAD CENTER FINAL RAD CENTER 36'-0" COMBINERS (E) QTY. - FINAL QTY. - FINAL MODEL - DI PLEXERS (E) QTY.(E) MODEL FINAL QTY.FINAL MODEL B1 B2 BE T A SE C T O R B3 B4 TOTAL:15 15 0 12 12 0 0 0 (E) RRUS FINAL RRUS MICROWAVE(s)(E) ANTENNA(s)FINAL ANTENNAS (E) DIPLEXERS(s)FINAL DIPLEXER(s)(E) COMBINERS 0 FINAL COMBINERS (E) QTY. RAYCAP (SURGE) (E) MODEL FINAL QTY.FINAL MODEL 3 FINAL RAYCAPS 3 (E) RAYCAPS C1 C2 GA M M A SE C T O R C3 C4 N/A N/A N/A RRUS-E2 B29 RRUS-4415 B30 RRUS-8843 B2/B66A RRUS-4449 B5/B12 N/A N/A N/A RAYCAP DC9-48-60-24-PC-EV RRUS-4478 B14 --- 4'1 --- -- -- --- - - - - - - - - LTE 700/ 850/LTE 1750 LTE FN/AWS / 700-DE - - - -1 1 1 2.5'1 5'COMMSCOPE NNH4-65A-R6H41 - - - - -- -- -- -- -- -- -- -- -- - - - - - - -- - - - - - - - - ------ -- -- - - - - - - - - ------ -- 1 -- -- -- -- -- -- -- -- -- -- -- - - - -- - --- - -- - -- -- ---- -- 1 1 1 RRUS-E2 B29 RRUS-4415 B30 RRUS-4478 B14 QUINTEL QS4658-7 36'-0"ERICSSON AIR6449 N77D CBAND CBAND/DoD2.5'INTEGRATED RRUS-8843 B2/B66A RRUS-4449 B5/B12 1 ERICSSON AIR6472 B77G/B77M 36'-6" QUINTEL QS4658-3E 4'1 QUINTEL QS4658-3E QUINTEL QS4658-7 4' 5' 4'LTE FN/AWS / 700-DE COMMSCOPE NNH4-65A-R6H4 LTE 700/ 850/LTE 1750 LTE FN/AWS / 700-DE LTE FN/AWS / 700-DE 36'-0" 36'-0"36'-0" 36'-0"36'-0" 4'1 LTE 700/ 850/LTE 1750 LTE FN/AWS / 700-DE 1 1 1 2.5'1 5'COMMSCOPE NNH4-65A-R6H41 QUINTEL QS4658-7 ERICSSON AIR6449 N77D CBAND CBAND/DoD2.5'1 ERICSSON AIR6472 B77G/B77M QUINTEL QS4658-3E 4'1 QUINTEL QS4658-3E QUINTEL QS4658-7 4' 5' 4'LTE FN/AWS / 700-DE COMMSCOPE NNH4-65A-R6H4 LTE 700/ 850/LTE 1750 LTE FN/AWS / 700-DE LTE FN/AWS / 700-DE 4'1 LTE 700/ 850/LTE 1750 LTE FN/AWS / 700-DE 1 1 1 2.5'1 5'COMMSCOPE NNH4-65A-R6H41 QUINTEL QS4658-7 ERICSSON AIR6449 N77D CBAND CBAND/DoD2.5'1 ERICSSON AIR6472 B77G/B77M QUINTEL QS4658-3E 4'1 QUINTEL QS4658-3E QUINTEL QS4658-7 4' 5' 4'LTE FN/AWS / 700-DE COMMSCOPE NNH4-65A-R6H4 LTE 700/ 850/LTE 1750 LTE FN/AWS / 700-DE LTE FN/AWS / 700-DE 15° 15°15° 15°15° 15°15° 170°36'-0" 36'-0"36'-6" 36'-0" 36'-0"36'-0" 36'-0"36'-0" 170° 280°36'-0" 36'-0"36'-6" 36'-0" 36'-0"36'-0" 36'-0"36'-0" 280° 170°170° 170°170° 170°170° 280°280° 280°280° 280°280° ---- ---- ---- - - - -- RAYCAP DC9-48-60-24-PC-EV1 RAYCAP DC9-48-60-24-PC-EV1RAYCAP DC9-48-60-24-PC-EV1 RAYCAP DC9-48-60-24-PC-EV1RAYCAP DC9-48-60-24-PC-EV1 -- -- -- - 1- 1- 6 3 6 3 - - - - - - -- - - 1 - - 6 - - 3 - - - - - - - - - - - - 0 123009 - ------ ---- -- - ---- ---- ----- ----- -- ---- ---- ----- ----- -- - - - - - - - - ------ -- -- - - - - - - - - ------ -- -- -- -- - 1- 1- 6 3 6 3 - - - - - - 1 1 -INTEGRATED RRUS-E2 B29 RRUS-4415 B30 RRUS-8843 B2/B66A RRUS-4449 B5/B12 RRUS-4478 B141 1 1 RRUS-E2 B29 RRUS-4415 B30 RRUS-4478 B14 INTEGRATED RRUS-8843 B2/B66A RRUS-4449 B5/B12 1 1 -INTEGRATED RRUS-E2 B29 RRUS-4415 B30 RRUS-8843 B2/B66A RRUS-4449 B5/B12 RRUS-4478 B141 1 1 1 1 1 1 RRUS-E2 B29 RRUS-4415 B30 RRUS-4478 B14 -INTEGRATED RRUS-8843 B2/B66A RRUS-4449 B5/B12 1 1 1 1 1 - 1 1 1 1 1 - 1 NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N A-4 EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS EXISTING EAST ELEVATION SCALE 32'16'8'08'4' 1/8"=1'-0"1 NOTE: 1.IF DIMENSIONS SHOWN ON PLAN DO NOT SCALE CORRECTLY, CHECK FOR REDUCTION OR ENLARGEMENT FROM ORIGINAL PLANS. 2.CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. EXISTING AND NEW EAST ELEVATIONS NEW EAST ELEVATION SCALE 32'16'8'08'4' 1/8"=1'-0"2 EXISTING BUILDING EXISTING AT&T PANEL ANTENNAS (TYP.-4 PER SECTOR.12 TOTAL) TO REMAIN EXISTING AT&T MW ANTENNAS (2-TYP.) EXISTING FRP SCREEN WALL LOUVER EXISTING AT&T PANEL ANTENNAS (TYP.-4 PER SECTOR.12 TOTAL) TO REMAIN ELEV. 0'-0" (REF) GROUND LEVEL EXISTING BUILDING EXISTING AT&T PANEL ANTENNAS (TYP.-4 PER SECTOR.12 TOTAL) EXISTING AT&T MW ANTENNAS (2-TYP.) EXISTING FRP SCREEN WALL LOUVER EXISTING AT&T PANEL ANTENNAS (TYP.-4 PER SECTOR.12 TOTAL) ELEV. 0'-0" (REF) GROUND LEVEL ELEV. 31-10" AGL TOP OF EXISTING PARAPET ELEV. 38'-0" AGL TOP OF EXISTING FRP SCREEN WALL AND AT&T PANEL ANTENNAS EXISTING AT&T AIR6449 B77D ANTENNA (TYP.-1 PER SECTOR. 3 TOTAL) TO BE REMOVED EXISTING AT&T AIR6449 B77D ANTENNA (TYP.-1 PER SECTOR. 3 TOTAL) TO BE REMOVED 1,2 A-5 NEW AIR6472 B77G/B77M ANTENNAS (1 PER SECTOR, 3 TOTAL) EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) RRU 8843 B2/B66A RELOCATED TO A1,A3,B1,B3,C1,C3 EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) RRU 4478 B14 RELOCATED TO A3,A4,B3,B4, C3,C4 EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) RRU 8843 B2/B66A TO BE RELOCATED TO A1,A3,B1,B3,C1,C3 EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) RRU 4478 B14 TO BE RELOCATED TO A3,A4,B3,B4, C3,C4 EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) RRU 8843 B2/B66A TO BE RELOCATED TO A1,A3,B1,B3,C1,C3 EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) RRU 4478 B14 TO BE RELOCATED TO A3,A4,B3,B4, C3,C4 EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) RRU 8843 B2/B66A RELOCATED TO A1, A3, B1, B3, C1, C3 EXISTING RRUS-LTE MOUNTED ON H-FRAME (12 PER SECTOR) RRU 4478 B14 RELOCATED TO A3, A4, B3, B4, C3, C4 ELEV. 36'-0" AGL RAD CENTER OF PANEL AND NEW AT&T AIR ANTENNAS ELEV. 31-10" AGL TOP OF EXISTING PARAPET ELEV. 38'-0" AGL TOP OF EXISTING FRP SCREEN WALL AND AT&T PANEL ANTENNAS ELEV. 36'-0" AGL RAD CENTER OF EXISTING PANEL AND AT&T AIR ANTENNAS ELEV. 36'-6" AGL RAD CENTER OF NEW AT&T AIR ANTENNAS NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N A-4.1 EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS EXISTING SOUTH ELEVATION 32'16'8'4'08'SCALE 3/32"=1'-0"1 NOTE: 1.IF DIMENSIONS SHOWN ON PLAN DO NOT SCALE CORRECTLY, CHECK FOR REDUCTION OR ENLARGEMENT FROM ORIGINAL PLANS. 2.CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. EXISTING AND NEW SOUTH ELEVATIONS 32'16'8'4'08'SCALE 3/32"=1'-0"2 EXISTING BUILDING EXISTING AT&T PANEL ANTENNAS (TYP.-4 PER SECTOR.12 TOTAL) TO REMAIN EXISTING FRP SCREEN WALL LOUVER EXISTING AT&T PANEL ANTENNAS (TYP.-4 PER SECTOR.12 TOTAL) TO REMAIN ELEV. 0'-0" (REF) GROUND LEVEL ELEV. 31-10" AGL TOP OF EXISTING PARAPET ELEV. 36'-0" AGL RAD CENTER OF EXISTING AT&T ANTENNAS ELEV. 38'-0" AGL TOP OF EXISTING AT&T ANTENNAS AND FRP SCREEN WALL EXISTING BUILDING EXISTING AT&T PANEL ANTENNAS (TYP.-4 PER SECTOR.12 TOTAL) EXISTING FRP SCREEN WALL LOUVER EXISTING AT&T PANEL ANTENNAS (TYP.-4 PER SECTOR.12 TOTAL) ELEV. 0'-0" (REF) GROUND LEVEL ELEV. 31-10" AGL TOP OF EXISTING PARAPET ELEV. 36'-0" AGL RAD CENTER OF EXISTING AT&T ANTENNAS ELEV. 38'-0" AGL TOP OF EXISTING AT&T ANTENNAS / FRP SCREEN WALL NEW SOUTH ELEVATION ELEV. 36'-6" AGL RAD CENTER OF NEW AT&T AIR ANTENNAS NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N A-5 EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS EQUIPMENT DETAILS ANTENNA MOUNTING SCALE NONE 1 ANTENNA SPECS SCALE NONE 2 SCALE NONE 4 ERICSSON - AIR6472 B77G/B77M MOUNTING - 2 NOT USED SCALE NONE 3 NOT USED NOT USEDNOT USED NOT USED NOT USED SCALE NONE 5NOT USED NOT USEDNOT USED NOT USED NOT USED NOT USED SCALE NONE 15 SCALE NONE 11 SCALE NONE 7 SCALE NONE 14 SCALE NONE 10 SCALE NONE 6 SCALE NONE 13 SCALE NONE 9 SCALE NONE 12 SCALE NONE 8 NOT USED ERICSSON - 6472 B77G/B77M 7.5"16.1" 36 . 4 SIDE FRONT BOTTOM NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N GN-1 Exp. 3/31/24 No E-19043REGISTEREDPROFESSIONALENGINEER TLECE IRC LAS ROFETAT O FILAC AIN J REMA DS UMMOND EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS DC POWER DIAGRAM / EQUIPMENT & ANTENNA GROUNDING NOT USED NOT USED EQUIPMENT & ANTENNA GROUNDING GN-2 5 GN-2 1 GN-2 16 NOTE: NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N Eukon www.eukongroup.com 65 POST, SUITE 1000 IRVINE, CA 92618 TEL: (949) 553-8566 an SFC Communications, Inc. Company CLL01585 1108 N. HARBOR BLVD. SANTA ANA, CA 92703 REV DATE DESCRIPTION SUBMITTALS A 04/12/25 90% CONSTRUCTION DRAWINGS PROJECT INFORMATION SHEET TITLE SHEET NUMBER DRAWN BY: MG --FE CONSTRUCTION DRAWINGS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. UTILITIES CHECKED BY: A&E CHECKED BY: 1452 EDINGER AVE. 3RD FLOOR TUSTIN, CA 92780 NOT F O R CON S T R U C T I O N GN-2 Exp. 3/31/24 No E-19043REGISTEREDPROFESSIONALENGINEER TLECE IRC LAS ROFETAT O FILAC AIN J REMA DS UMMOND EU K O N _ A T & T _ 7 5 C D _ M O N O P O L E T E M P L A T E _ V 2 _ 1 1 - 1 8 - 2 2 0 06/27/25 100% CONSTRUCTION DRAWINGS GROUNDING DETAILS NOT USED NOT USED NOT USED CABLE GND. KIT TO ANT. NOT USED NOT USED NOT USED GND. WIRE TO GND. BAR EXOTHERMIC WELD NOT USED GROUND BAR DETAIL MECHANICAL CONNECTION GROUNDING NOTES GND. WIRE TO GRD. BAR SCALE NONE 1 SCALE NONE 2 SCALE NONE 4 SCALE NONE 5 SCALE NONE 7 SCALE NONE 8 SCALE NONE 9 SCALE NONE 10 SCALE NONE 11 SCALE NONE 12 SCALE NONE 13 SCALE NONE 14 SCALE NONE 15 SCALE NONE 16 2. 3. 1.DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. WEATHER PROOFING SHALL BE (TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER.) 2 1 1 / 1 6 " D I A . M A X . 12" TO 24" NOTES: 1. 2. ANTENNA CABLE TO BTS EQUIPMENT (TYP) ANDREW SUREGROUND TYPE GROUND KIT (TYPICAL) (SEE NOTE) WEATHERPROOFING KIT (TYP.) ANTENNA GROUND BAR, SIMILAR TO DETAIL 3 WITHOUT INSULATORS. BONDED DIRECTLY TO TOP OF POLE OR TOWER. TX1 CONNECTOR WEATHERPROOFING KIT (TYP.) SEE NOTE 2 COAX JUMPER (TYP.) #6 AWG TO ANTENNAS DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. WEATHER PROOFING SHALL BE ANDREW TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. RX1 TWO HOLE LONG BARREL LUG. TO BE USED WITH # 2 AWG CU STRANDED WIRE WITH GREEN, 600V THWN INSULATION TO BTS CABINET. USE STAINLESS STEEL HARDWARE. #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION (AS REQUIRED) - 8 NOTES: 1 1- UNIVERSAL TINNED COPPER BUSS BAR WITH HARDWARE: BY ANDREW CORPORATION UGBKIT-0420-T : 1/4"x4"x20" (SHOWN) UGBKIT-0412-T : 1/4"x4"x12" UGBKIT-0210-T : 1/4"x2"x10" GB-HKU : MOUNTING HARDWARE KIT 2-ANDREW #MTC9674KEY TAMPER RESISTANT BUSS BAR BOLT KIT 2 NOTE: HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. NOTES 1.NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATION, AND CONNECTION ORIENTATION, THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ADDITIONAL GROUNDING BAR AS REQUIRED, PROVIDING 50% SPARE CONNECTION POINTS. 2.DO NOT INSTALL CABLE GROUNDING KIT AT A BEND AND ALWAYS DIRECT GROUNDING CONDUCTOR DOWN TO GROUNDING BAR. 3.GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 4.WEATHER PROOFING SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 5.PROVIDE GROUNDING KIT 6” BEFORE TURN TRANSITION FROM TOWER TO ICE BRIDGE. 6.WHEN THE SCOPE OF WORK REQUIRES THE ADDITION OF A GROUNDING BAR TO AN EXISTING TOWER, THE SUBCONTRACTOR SHALL OBTAIN APPROVAL FROM THE TOWER OWNER PRIOR TO MOUNTING THE GROUNDING BARS TO THE TOWER. 7.EXTEND TWO (2) #2 AWG TINNED CU CONDUCTOR FROM BURIED GROUNDING RING AND CONNECT TO THE PROPOSED TOWER, FOLLOW MANUFACTURERS RECOMMENDATIONS FOR GROUNDING CONNECTIONS TO THE TOWER. (APPLICABLE TO NEW TOWERS ONLY.) 8.BUILDINGS AND/OR NEW TOWERS GREATER THAN 75 FEET IN HEIGHT AND THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOF-TOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 AWG COPPER, ROOF-TOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY), SEE AT&T GROUNDING AND BONDING STANDARDS TP—76416 SPECIFICATION 6.5.2.2. 9.FLEX CONDUIT TO BE INSTALLED ON PROPOSED COPPER CONDUCTOR UP TO GROUNDING BAR AND, SEALED AT ENDS TO PROTECT FROM OUTSIDE MOISTURE AND DEBRIS. NEW EQUIPMENT GROUND BAR#6 SWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) (SEE NOTE 1 & 2) CABLE GROUND KIT WEATHERPROOFING KIT (SEE NOTE 3) ANTENNA CABLE 1 BOLT PARALLEL CLAMP CAST ``T'' SPLICER 2 HOLE LUG ``U'' BOLT PIPE CLAMP 1 BOLT PARALLEL CLAMP UNIVERSAL PIPE CLAMPS 50H2 CROSS RUN CLAMP UNIVERSAL PIPE CLAMPS 75/1.25 2 BOLT PARALLEL SPLICER BOLT GRND. ROD CLAMP TYPE RRTYPE PCTYPE GL LUGTYPE GRTYPE XA TYPE LJ TYPE HA TYPE VS TYPE NX1 TYPE ND TYPE NCTYPE GYTYPE GTTYPE PG TYPE SS TYPE TA TYPE VB TYPE PH TYPE GR NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N NOT F O R CON S T R U C T I O N YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs