Loading...
HomeMy WebLinkAboutHISTORIC-1904 N Heliotrope Dr - REV 1 - PlanPV-1 18" Setbacks 36" Setbacks ROOF PLAN Sheet: Date: 12.10.2025 Residential Roof Mounted Photovoltaic System Courtney Construction Project Name and Address: 1904 Heliotrope Dr, Santa Ana, CA 92706 Title: NRG Clean Power 7012 Owensmouth Ave Canoga Park, CA 91303 1-888-650-4750 www.nrgcleanpower.com Lic# C10-1026168 Oren Tamir System Size (DC): Modules: x SEG Solar 405W (SEG-405-BMD-HV) 40 Inverter & Battery: x 11.5 KW / 13.5KWH Tesla Powerwall 3 1707000-xx-y(120/240V) System Size (AC-CEC): x =40 405 16.20 KW 1 x x =40 376.5 0.975 14.68 KW MCI: xTesla PV Rapid Shut Down MCI-112 ROOF AREA CALCULATIONS FIRE SPRINKLERS - NO TOTAL ROOF AREA (SQ.FT.)3460 SOLAR AREA (SQ.FT.)840 % OF COVERED AREA 24.28 NOTE: PVC conduit and fittings directly buried in earth at a depth not less than 18" FILL AND COMPACT SOIL IN TRENCH ON TOP OF CONDUIT WARNING RIBBON 12" ABOVE CONDUIT SCHEDULE 40 PVC CONDUIT BURIED MINIMUM 18" CONDUIT BURIAL DETAIL GROUND LEVELGROUND LEVEL CONDUIT BURIAL DETAIL SCHEDULE 40 PVC CONDUIT BURIED MINIMUM 18" WARNING RIBBON 12" ABOVE CONDUIT SCALE 20ft1050 SCH 40 PVC Conduit Through Underground Trench ~ 23 feet 150' 110' 15' 45' 41' 69' Driveway Public Sidewalk Heliotrope Dr Pu b l i c S i d e w a l k W 1 9 t h S t MSP (E)SSP (Backup Panel) Tesla Backup Gateway Solar Array 1 14 REC Solar 405W 4 Tesla RSD Pitch: 18 Deg Orientation: 0 Deg Solar Array 2 26 REC Solar 405W 8 Tesla RSD Pitch: 18 Deg Orientation: 270 Deg J/B POOL aaaaaa bb bb b bb c c c c d d d d d e e e e e e e f f f f c (E) GARAGE (E) SUNROOM DCD Overhead Feed DC conductors and AC conductors shall be ran in separate condu f f f d d a Battery DCD ELECTRONICALLY SIGNED:12/10/2025 EQUIPMENT INFORMATION MSP Main Service Panel SM Solar Module JB JBox PVC Junction Box NEMA type 3 TRSD Tesla RSD Tesla PV Rapid Shut Down MCI-1 TP Tesla Powerwall 3 Tesla Powerwall 3 11.5 KW / 13.5 KWH 1707000-xx-y SSP Service Sub Panel (Backup Panel) Existing Service Sub Panel 120/240V 1P/3W, 200A DCD DC Disconnect Tesla Backup Gateway Tesla Backup Gateway NEMA type 3, 200A Max Sheet: Date: 12.10.2025 Residential Roof Mounted Photovoltaic System Courtney Construction Project Name and Address: 1904 Heliotrope Dr, Santa Ana, CA 92706 Title: NRG Clean Power 7012 Owensmouth Ave Canoga Park, CA 91303 1-888-650-4750 www.nrgcleanpower.com Lic# C10-1026168 Oren Tamir System Size (DC): Modules: x SEG Solar 405W (SEG-405-BMD-HV) 40 Inverter & Battery: x 11.5 KW / 13.5KWH Tesla Powerwall 3 1707000-xx-y(120/240V) System Size (AC-CEC): x =40 405 16.20 KW 1 x x =40 376.5 0.975 14.68 KW MCI: xTesla PV Rapid Shut Down MCI-112 PV-2 ELECTRICAL 1 LINE DIAGRAM Existing /300A SPLIT Utility Meter & Main Service Panel 120/240V 1P/3W 2x150A SEG Solar 405W Modules (SEG-405-BMD-HV) String a: (7) Modules, (2) Tesla PV Rapid Shut Down String b: (7) Modules, (2) Tesla PV Rapid Shut Down String c: (5) Modules, (2) Tesla PV Rapid Shut Down String d: (7) Modules, (2) Tesla PV Rapid Shut Down String e: (7) Modules, (2) Tesla PV Rapid Shut Down String f: (7) Modules, (2) Tesla PV Rapid Shut Down Max DC Voltage For Inverter:7 x 37.2 x 1.12 = 291.6 <=550V 60A M UTILITY NEW GROUNDING SYSTEM (1)1/0 AWG EGC/CU MSP 150A150A (3) #1/0 AWG THWN-2 (1) #6 AWG EGC/CU 1 1/2'' EMT TYPE CONDUIT Tesla Backup Gateway 20 0 A B U S (N)150A A SM TRSD C Existing Service SUB Panel (Backup Panel) SSP (2) #18 AWG THWN-2 (Blue, white) Consumption CT TP B B J BOX NEMA 3R JB Type 2 - Panel base surge protector device is used 20A The new service panel is overhead feed. NFPA 70 705.13 Compliant Power Control System interconnection method is used.(See page PV-6) 20A 15A 15A 15A 20A 20A 20A 40A 20A 20A 20A 20A 20A 20A 20A 15A 15A 15A 15A 15A 20A 20A 15A 15A 60A Non Fused DC Disconnect Lockable, Blade Type, NEMA 3R, 120/240V B DCD PCS Controlled Current Setting: 120 A The maximum output current from this system towards the main panel is controlled electronically.Refer to the manufacturer's instructions for more information. N N N N Neutral Isolated. Remove factory-installed main neutral-ground bonding screw in Gateway Neutral bonded to ground Neutral Isolated from ground All neutral conductors are on a separate isolated bus from the EGC conductors. The GEC/EGC bus must be bonded to the subpanel cabinet. (3) #1/0 AWG THWN-2 (1) #6 AWG EGC/CU 1 1/2'' EMT TYPE CONDUIT l W V A V A LBS W PV-3 ELECTRICAL CALCULATION MODULE CHARACTERISTICS - 405 37.22 13.7 30.93 13.10 47.4 376.5 SEG 405W SEG-405-BMD-HV Max Power Open Circuit Voltage (Voc) Short Circuit Current (Isc) Max Power Voltage (Vmp) Max Power Current (Imp) Modules Weight PTC Power Rating Sheet: Date: 12.10.2025 Residential Roof Mounted Photovoltaic System Courtney Construction Project Name and Address: 1904 Heliotrope Dr, Santa Ana, CA 92706 Title: NRG Clean Power 7012 Owensmouth Ave Canoga Park, CA 91303 1-888-650-4750 www.nrgcleanpower.com Lic# C10-1026168 Oren Tamir System Size (DC): Modules: x SEG Solar 405W (SEG-405-BMD-HV) 40 Inverter & Battery: x 11.5 KW / 13.5KWH Tesla Powerwall 3 1707000-xx-y(120/240V) System Size (AC-CEC): x =40 405 16.20 KW 1 x x =40 376.5 0.975 14.68 KW MCI: xTesla PV Rapid Shut Down MCI-112 AC WIRE SIZING CALCULATION At Inverter (C)3 x (#6) AWG THWN-2 1 x (#8) AWG CU EGC 3/4" EMT TYPE CONDUIT MAXIMUM INVERTER OUTPUT CURRENT 48.0 CONSIDER CONTINUOUS COEFFICIENT 1.25 TEMPERATURE FACTOR 0.91 CONSIDER CONTINUOUS 48.0 x 1.25 60.0 TEMPERATURE ADJUSTMENT 60.0 / 0.91 65.9 DC WIRE SIZING CALCULATION At Array (A)12 x (#12) AWG PV-WIRE 1 x (#6) AWG BARE CU EGC FREE IN THE AIR 3xAt Array (B)4 x (#10) AWG THWN-2 1 x (#8) AWG CU EGC 3/4"/1" PVC EMT TYPE CONDUIT MAX NUMBER OF MODULES IN STRING 8 MODULES OPEN CIRCUIT VOLTAGE (VOC)37.2 8 x 37.2 x 1.12 =333.5 V <= 550 (V). SHORT CIRCUIT CURRENT 13.70 CONSIDER CONTINUOUS COEFFICIENT 1.25 RACEWAY HEIGHT 7/8" ABOVE ROOF 1.0 SHORT CIRCUIT CURRENT 13.70 x 1.25 x 1.25 21.4 ADJUSTED CONDUCTOR AMPACITY 21.4 /0.8 /1.0 26.8 ADJST. FACTOR (4 thru 6 wires)0.8 (A) (A) (A) (A) (A) SYSTEM MECHANICAL INFO Solar module weight 47.4 LBS PV Solar Module Quantity 40 N/A Attachment quantity 70 N/A Total solar area 840 SQFT Total modules weight 1896 LBS Microinverters/Optimazers weight 9 LBS Racking weight 379 LBS Total system weight 2284 LBS Solar array weight per attachment 32.6 LBS Solar array dead load 2.72 LBS/SQFT Attachment spacing 72" STACKED Racking type Attachment type Framing 2" x 6" 24'' O.C. Finished roof surface is Sheet: Date: 12.10.2025 Residential Roof Mounted Photovoltaic System Courtney Construction Project Name and Address: 1904 Heliotrope Dr, Santa Ana, CA 92706 Title: NRG Clean Power 7012 Owensmouth Ave Canoga Park, CA 91303 1-888-650-4750 www.nrgcleanpower.com Lic# C10-1026168 Oren Tamir System Size (DC): Modules: x SEG Solar 405W (SEG-405-BMD-HV) 40 Inverter & Battery: x 11.5 KW / 13.5KWH Tesla Powerwall 3 1707000-xx-y(120/240V) System Size (AC-CEC): x =40 405 16.20 KW 1 x x =40 376.5 0.975 14.68 KW MCI: xTesla PV Rapid Shut Down MCI-112 PV-4 STRUCTURAL INFORMATION ATTACHMENT DETAIL Wind speed 95 MPH Snow load 0 PSF Exposure C ASCE 7-16 - IronRidge S concrete tile All Tile Hook MIN EMBEDMENT 2.5" LAG BOLTS 5/16" x 4'' 7.5 3.8 2 1.18 7.09 2.13 5.51 3 1 NO. 1 2 3 DESCRIPTION ASSY, ALL TILE HOOK BOLT, LAG 5/16 X 4" BASE ASSY, ALL TILE HOOK DO NOT SCALE DRAWING WEIGHT: LBS SHEET 1 OF 1 A SIZE SCALE:1:4 Rafters 72'' 24'' 2''X6'' Blocking 2''X4'' Support 2''X4'' Purlin 2''X6'' Collar Tie SOLAR MODULE Max 6'' ATTIC DETAIL STRUCTURAL NOTES: THESE PLANS ARE STAMPED FOR STRUCTURAL ADEQUACY OF EXISTING ROOF SYSTEM TO SUPPORT THE PROPOSED PV SYSTEM AND ITS MOUNTING COMPONENTS. PLEASE SEE ACCOMPANYING CALCULATION REPORT FOR FULL DETAILS AND SCOPE OF WORK. NOTES FOR INSTALLERS: 1. INSTALLER TO INSTALL ALL COMPONENTS PER MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTION. 2. INSTALLER TO NOTIFY E.O.R. OF ANY DAMAGE OR RED FLAGS NOT NOTED IN THIS REPORT PRIOR TO COMMENCEMENT OF WORK. E.O.R. WILL EVALUATE AND PROVIDE FURTHER DIRECTION AS NECESSARY. 3. INSTALLER TO VERIFY THE ROOF FRAMING AS FOLLOWS: 2X6 RAFTERS @ 24" OC WITH MAX UNSUPPORTED SLOPED SPAN OF 12'-0". IF ANY DISCREPANCIES ARE FOUND WITH THE ON SITE CONDITIONS THEN THE E.O.R IS TO BE NOTIFIED PRIOR TO INSTALLATION. E.O.R. WILL EVALUATE AND PROVIDE FURTHER DIRECTION AS NECESSARY. ELECTRONICALLY SIGNED:12/10/2025 Sheet: Date: 12.10.2025 Residential Roof Mounted Photovoltaic System Courtney Construction Project Name and Address: 1904 Heliotrope Dr, Santa Ana, CA 92706 Title: NRG Clean Power 7012 Owensmouth Ave Canoga Park, CA 91303 1-888-650-4750 www.nrgcleanpower.com Lic# C10-1026168 Oren Tamir System Size (DC): Modules: x SEG Solar 405W (SEG-405-BMD-HV) 40 Inverter & Battery: x 11.5 KW / 13.5KWH Tesla Powerwall 3 1707000-xx-y(120/240V) System Size (AC-CEC): x =40 405 16.20 KW 1 x x =40 376.5 0.975 14.68 KW MCI: xTesla PV Rapid Shut Down MCI-112 PV-5 CODE REQUIRED SIGNAGE CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 1 WARNING: PHOTOVOLTAIC POWER SOURCE On Ext. and Int. Conduit Every 10 Feet and within 1' of turns and within 1' above/or below penetrations and all Junction Boxes. Reflective. CAUTION: PHOTOVOLTAIC J-BOX2 3 WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED 4 WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH THE TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. PV SUB-PANEL ONLY5 To be located on SUB-panel only when SUB-panel is dedicated for PV only 7 SOLAR8 Sticker located inside panel next to solar breaker 9 WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE Sticker located inside panel below PV breaker 10 PV LOAD CENTER SIZED FOR PV BREAKERS ONLY OR RENDERED UNABLE TO ACCEPT ANY ADDITIONAL LOADS. Sticker located on the PV SUB panel. 11 CAUTION MULTIPLE SOURCES OF POWER 705.12 (D)(3) 12 RAPID SHUT DOWN SWITCH FOR SOLAR PV SYSTEM SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH ON THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY 13 Note: Materials used for all marking shall be reflective, weather resistant and suitable for the environment. All letters shall be a minimum height of 3/8", capitalized and white on a red background. 1 2 PV ARRAY J BOX INVERTER *if applicable INTEGRATED DC DISCONNECT PV SUB-PANEL *if applicable *if applicable SUB-PANEL AC DISCONNECT *if applicable MAIN SERVICE PANEL1111 3 4 5 6 7 8 9 10 6 7 8 9 10 6 PV METER *if applicable M M 11 9 11 12 6 7 8 13 14 RATED AC OUTPUT CURRENT- 48.0 A MAX NOMINAL AC OPERATING VOLTAGE: 240 Vac Sticker located on Powerwall 3 Inverter AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE 6 THIS PANEL FED BY MULTIPLE SOURCES (UTILITY,SOLAR & BATTERY) He l i o t r o p e D r Solar Modules Solar Modules (E)Service SUB Panel (Backup Panel) Service Point & Utility Metering Battery Tesla Backup Gateway PCS Controlled Current Setting: 120 A The maximum output current from this system towards the main panel is controlled electronically.Refer to the manufacturer's instructions for more information. CT Field Marking Label WARNING: THIS SENSOR IS PART OF POWER CONTROL SYSTEM. DO NOT REMOVE. REPLACE ONLY WITH SAME TYPE AND RATING (2) disconnect placards will be required. 1-at the Gateway and 1- at the service.DC Disconnect DC Disconnect