Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
10180153_600 S. GRAND 600 - Plan (2)
Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana. ora ELECTRICAL SIGN REQUIREMENTS Code references are to the 2010 California Electrical Code (CEC) All signs require Planning Department approval. All electrical signs require electric plancheck and permit. 1. Manufacturer's instructions are required at the time of submittal C-11: 3-21-2011 2. Submit detailed installat;ion instructions including diagrams to the Building Department for plan review at the time of submittal. Plans must include appropriate items noted by this bulletin. 3. Cash or surety bond in the amount of $200.00 is required at time of issuance for each address. The cash or surety bond will be refunded after all required finals. A building permit is also required - except for open or highlight neon lighting. Installation Requirements: CONTACT FIELD INSPECTOR PRIOR TO SIGN INSTALLATION. (SEE SECTION G OF THIS BULLETIN) 1. Conductors and equipment shall comply with California Electric Code Article 600. 2. All metal parts of a sign shall be bonded in the manner specified in Article 250. Isolated metal parts are permittdd to be bonded by using an external green insulated conductor. Equipment grounding & bonding conductors must be sized by 110.26 and protected from physical damage. Minimum size is 14 AWG. CEC 600.7 3. A listed disconnect switch in the power supply primary, shall be installed within sight of sign or have permanently installed means for locking in an "OFF" position. This is also true for a transformer enclosure. CEC 600.6 4. A listed receptacle or an approved termination device shall be used for each neon electrode. To relieve stress at terminations, tubing shall be supported with listed tube supports in an approved manner within six inches of electrode connection. CEC 600.41 & 600.42 5. Every electric sign of any type shall be listed by an approved testing laboratory and shall be installed in conformance with this listing. That includes "1 of x", "2 of x" labeling for each separate unit of a multi-unit sign. CEC 600.3 6. All "can" letters and transformers housings shall have section labels that are readily visible after installation. CEC 600.4 7. Transformers shall be located where accessible and be securely fastened in place. Page 1 of 2 0 0 00 P When not inside the sign, they need a 3 foot high x 3 foot wide x 3 foot deep workspace. Transformers are permitted to be located in attics or canopies provided there is a passageway at least 3 feet high x 2 feet wide with a minimum 12 inch catwalk/walkway from the point of entry. Transformers must be securely fastened and independent of T- bar when above a suspended ceiling. No part of sign may be fed with flexible cord when located above T-bar ceilings. CEC 600.21(E&if) & 400.8 8. Adequate illumination shall be provided for all working spaces about electrical equipment. This applies to attics and canopies when entry is required to service or inspect the equipment. At least one switch is required at entrance. CEC 110.34 & 600.21 9. Doorway to an attic or canopy space shall be minimum 3 feet by 2 feet wide. CEC 6i00.21(E) E. Open neon outline or highlight lighting. 1. To be treated as a sign by this department. However, Section D-5 & D-6 of this bulletin will not apply. 2. Neon tubing shall be located where not normally exposed to physical damage. Open neon tubing below 9 feet shall be protected from physical damage by an approved shielding method. CEC 600.30 and 110.34(E) F. Light-Emitting Diode (LED) Signs 1. Will be treated as a sign by this department. All sign rules in sections A, B, C, D, F, and G will apply as appropriate. 2. LED illumination for signage must be a listed or recognized component. Many LED manufacturers specify particular brands and models of transformers some do not. Manufacturer information to clarify this issue is required on LED sign plans. 3. Unlisted LEDs may not be used in an electrical sign or as permanently installed illumination. 110.3 4. Please have packaging or catalog cut-sheets on hand for inspector to review when LED modules do not bear listing symbols. G. Inspections 1. Contact an Electrical Inspector one (1) workday (minimum) in advance of installation to arrange a site meeting on dav of installatioo. 2. Call for inspection Monday through Friday, 8:00- 8:30 a.m. at (714) 647-5821. Approved prints and the job card must be on site for inspection. Page 2 of 2 51 SIGN COMPONENTS MANUAL (SAM)October 1, 20.3 LED 60CV 12P 100 - 277 0.8-0.3 12 60 LED 60CV 24P 100 - 277 0.8 - 0.3 24 60 3. These power supplies are only suitable for use in dry and damp locations. 4. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum,2 inches spacing to top of enclosure. Compahy name or trademarks Light€:ch™ d Ligh·echLED Driver Hologen Tran#forme#and model designation. GE LIGHTING SOLUTIONS LLC BLDG 338E 1975 NOBLE RD EAST CLEVELAND, OH 44112 USA E219167 Border tube kits, Includes Lens Cat. No. GExxBTL; Lens connector Cat. No. GExxBILC: End cap Cat. No. GExxBTLEC: Exterior corner kit Cat No GExxBTLXC, Interior corner kit Cat. No. GExxBTLIC: Base reflector Cat No. GEBTBR: Base connector Cat. No. GEBTBC; Cam lock Cat. No. GEBTCL. Canopy Kits. Cat. No. GECPL (8 ft length), GECPEC (end cap), GECPLC, (lers connector), GESTBCL, GEBTBC. Light guide kits includes: Light guide Cat. No. GEXNLGXX-XXX, Light Guide End Cap Cat. No. GEXXXNLGECZZ, XXX may be any alpha letter representing color. ZZ may be any alpha letter representing size. Light Guide Connector Cat. No. GEXXXNLGYZZ, XXX may be any alpha letter representing color, Y can be any alpha character describing the type of connector. ZZ may be any alpha letter representing size.. Mounting clip Cat. No GEXNMCXX; Supply wire Cat. No. GEXNSXX: Spice connector Cat. No. GEXNSC1: Weather box Cat. No. GEXWBXX-XXX. 1. Border Tube Kit, Canopy Kit and Light Guide Kit are for Wet Location only use when enclosing LED's connected to a Class 2 circuit operating at under 30V continuous DC. 12.4'V interrupted at a rate of 10-200Hz DC, or 15 VAC. 2. The LED border tube kit and Canopy Kit was not evaluated as an electrical enclosure. 3. The LED border tube kit and Canopy Kit was not evaluated as a watertight housing. LED power supplies, Cat. No. GEXLPS21, GEXNPS30-120, GEXNPS31-120 1. This component has been judged on the basis of the required spacings in the Standard for Class 2 Power Units, UL 1310, Fourth Edition, which would cover the component itself if submitted for Listing. 2.The supply terminals and connectors are suitable for factory pbring only of solid or tinned stranded No. 18 AWG conductors. 3.The equipment was submitted and tested for a maximum manufacturer's recommended ambient (Trnra) of 40 C. 4. Leakage current measurements shall be performed when more than four LED drivers are used in the equipment or when the LED driver is used in combination with other equipment in the end-use product. 5. The drivers are intended for installation inside an electrital enclosure. 6. The ground connectipn is not suitable as the equipment ground for a sign. Separate provision for sign grounding must be provided. 7. The drivers are suitable for dry location use only except the drivers Models GEXNPS30-120 and GEXLPS21 are suitable for damp location use. LED array drivers, Models GEXLPS21-U, GEPS12-60U, GE060/MV/\/12T12T1-A 1. These components have been judged on the basis of the required spacing in the Standard for Class 2 Power Units, UL 1310, Fourth Edition, which would cover:the component itself if submitted for Listing. 2. The terminals and connectors afe suitable for factory wiring only of solid or tinned stranded No. 18 AWG conductors. 3. The equipment was submitted and tested for a maximum manufacturer's recommended ambient (Tmra) of 40°C. 4. The insulation system of;the main isolation transformer designated (T2) in these models is a Class 105(A) insulation system. Unless the modules are mounted as specified in condition of acceptability number 7, a temperature test is required when these models installed within an electrical enclosure or raceway. 5. The maximum measured leakage current of a single unit is 0.49 mA. Leakage current measurements shall be performed when multiple LED drivers are used in the final equipment or when the LED driver is used in combination with other equipment in the end-use product. 6. The unit is intended for installation inside an electrical enclosure. 7. The unit may be used within an electrical enclosure or raceway without temperature test provided they are mounted not closer than 1 in. end to end or 4 in. side to side from adjacent LED power supplies. 8. The ground connection 'is not suitable as the equipment ground for a sign. Separate provision for sign grounding must be provided. LED power supplies, Model GEPS24-100U, GE100/MVA/24T1-A. 1. This component has been judged on the basis of the required spacing in the Standard for Class 2 Power Units, UL 1310, Fourth Edition, which would cover the component itself if submitted for Listing. 2. The supplyterminals and connectors are suitable for factory wiring only of solid or tinned stranded No. 18 AWG conductors. 3. The equipment was submitted and tested for a maximum manufacturer's recommended ambient (Tmra) of 40 C. 4. This unit is provided with a Class 105(A) insulation system. A temperature test is requited when the unit is installed within an electrical enclosure or raceway. 5. Leakage current measurements shall be performed when more than four LED drivers are used in the equipment or when the LED driver is used in combination with other equipment in the end-use product. 6. The unit is intended for installation inside an electrical enclosure. 7. The unit may be used within an electrical enclosure or raceway Without temperature test provjded they are mounted not closer than 1 in. end to end or 4 in. side to side from adjacent LED power supplies. LED array drivers, Models GEPS 12-20, GEPS 24-20. 1. The maximum measured output voltage, current and power at the output of these models was found in compliance with the limits for Class 2 output requirements. 2. The transformers of these units employ Class 105 insulation system. 3. These components were intended for use in indoor Dry and DAMP location only. October 1,2013 SIGN COMPONENTS MANUAL !(SAM) 52 4. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. Adjacent power supplies shall be spaced at least 1 in. end to end and 4 in. in any other direction. 5. These components shall be installed inside an electrical enclosure. 6. Input and Output leads are style 1316, rated 600 V. 105 C, VW-1. Minimum No. 18 AWG. The suitability of input and output connections shall be determined in each end use application. 7. The maximum room ambient temperature permitted by the manufacture is 60 C. The temperature measured on outside enclosure of Models GEPS24-20 and GEPS12-20 are 67.2 C and 77.9 C respectively. The necessity of repeated Temperature Test shall be determined in each end use application if minimum thermal spacings in accordance with Item 4 are not provided. LED Dimmer, Model GEDM 1 and GEDM 1-A. 1. This component has been judged on the basis of the required spacing in the Standard for Classi2 Power Units, UL 1310, Fourth Edition, which would cover the component itself if submitted for Listing. 2. The equipment was submitted and tested for a maximum manufacturefs recommended ambient (Tmra) of 40 C. 3. The unit is intended for installation inside an electricalenclosure. 4. This unit is provided with a Class 105(A) insulation system. The unit may be used within an electrical enclosure or raceway without temperature test provided they are mounted not closer than 1 in. end to end 'or 4 in. side to side from adjacent LED power supplies. 5. The Xitanium Dimmer is only suitable for use in Class 2 dircuits powered by Advance LED drivers with maximum input rating of 24Vdc. 4. lA, or 12VDC, 5A. Dimmer circuit is 0-10VDC. '6. This LED Dimmer Controller must be used with either a 100K Ohms Potentiometer or a standard 0-10 V DC dimmer switch. 7. For dry or damp location. LED Strips, Class 2, Cat. Nos. GE-XX-XX-X-XXX, GE-XX-XX-XX-XXX, GE-XX-XX-XXX-XXX, GE-XX-XX-XXXX-XXX, GE-XX- XX-XXXXX-XXX, GE-XX-XX-XXXXXX-XXX, GE-XX-XX-XXXXXXX-XXX, GE-XX-XX-XXXXXXXX-XXX, GE-XX-XX XXXXXXXXX-XXX, catalog numbers may vary per nomenclature. GE followed by DOC representing color: RD, RC, YG, GL, SB, BL, WH, YA, WW, GR, PO: followed by· "XX" representing product line: CL, DS, XL, PT, XN, TM, MX, TU, PG, PX, PH, XH, MH. SS, PM. MM, MH, BS, BD, BI followed by: "X" to -XXXXXXXXX- representing light strip final assembly or number of LEDs per foot: LA, LEI AA, SX, LX, WXX, TXX, PX, XX followed by: "XXX" denotes any alphanumeric character that represents the color temperature ofthe LEDs. Cat. Nos. GE-AA-BB-CC, where"AA" may be DS, XN, XNL, XNA, MX, MXL, PG, MM MIVID, SS, PM, PMD, MXH, MXHL, BS, BD, Bl, BIH, BSH BDH, DSH or SSH which represent product line; "BIB" may be RD, RC, YG, GL, SB, BL, WH, YA, WW, GR, PO or any alphanumeric character: and "CC" may be any alphanumeric characters or blank. 1. These products are only suitable for connection to a Class 2 power source. 2. When units are connected to a Class 2/ LPS circuit, they are not to drawa total wattage of greater than the secondary or output rating of the Class 2/ LPS supply. 3. These products are suitable for use in dry, damp and wet locations. 4 These products described in this section may be cut into segments per manufacture insulation instructions. 5. Units may be provided with UYMR2,3M type VHB double-sided adhesive tape. Tape must'be utilized per UYMR2 Conditions of Use as defined in the Sign Components Manual. 6. The Light Guide has not been evaluated as an LED Strip Light enclosure or diffuser. Suitability shall be determined in the end use product. NOMENCLATURE: Nomenclature for LED Strip Light: GE-XX-XX-X-XXX, GE-XX-XX-XX-XXX, GE-XX-XX-XXX-XXX, GE-XX-XX-XXXX-XXX, GE-XX- XX-XXXXX-XXX, GE-XX-XX-XXXXXX-XXX, GE-XX-XX-XXXXXXX-XXX, GE-XX-XX-XXXXXXXX-XXX, GE-XX-XX-XXXXXXXXX XXX. First Set of DO<" = denotes the color of the LED RD =Red family RC =Red/Orange family YG =yellow family GL =Green family SB,BL .Blue Family WH := :White YA Amber WW = Warm White GR =Green PO = Portland Orange Second Set of "XX" = ddhotes product line CL = channel letter DS = double sided Power Strip XL = tetra long strip PT power tetra XN. XNL. XNA =Contour or Contour LS TM = Mini MX, MXL = Max TU = Ultra PG = Power Grid PX = Power White XL Ptl = Power White HO XH = Power White XL HO MM, MMD =Mini Max SS = power Strip 53 SIGN COMPONENTS MANUAL (SAM)October 1, 2013 PM, PM D = Power Max MH. MXH,MXHL =MAX HO BS = Shallow Box single sided BD = Shallow Box double sided 81 H = Edgestrip Third set of "XX" denotes Light Strip final assembly as noted below. LA ] =Light Strip. assembled inside a plastic rod, 8 inch section LE =Light Engine means same as Light strips AA F Light engine, assembled inside a plastic rod, 16 inch section SX or X j = Number of LEDs_£er foot where Xis 1 =6 LEDs per foot etc. (X can be representative 09 1-Fog digits) \AD<X =Wide Angle light diffUEr .where the first X describes the PCB length, A for regular and L for long, and the second X is an alpha numeric character of leds per foot. PX" -='' For PowerGrid (PGE-Pomr Strip (SS) and Double Sided Power St®-IDS) only, where x equals the number of LEDs per foot. Not Assembled in Tube. An optional X may be added to denote wire length between modules where X is S for short, M for Medium, and L for Long. XX =only to be used with DS product line, xx is number that correlates to total length in inches (48 = 48") assembled in acrylic tube. _- "XXX" deriotiu any alphanumeric character that denotes the Color Temperature of the LEDs i.e. 65k = 6500,75k = 7500 etc. Splice connector, Cat. No. GexxSCx, End caps, Cat. No GexxECx. 1. These products are only suitable for connection to a Class 2 power source. 2. When uhits are connected to a Class 2/"LPS" circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2/"LPS" supply 3. These products aie suitable for use in dry, damp and wet locations. 4. These products described in this section may be cut into segments per manufacture insulation instructions. 5. Units may be provided with UYMR2,3M type VHB double-sided adhesive tape. Tape mwst be utilized per UYMR2 "Conditions of Use" as defined in the Sign Components Manual 6. The Light Guide has 'not been evaluated as an LED Strip Light enclosure or diffuser. Suitability shall be determined in the end use product. LED Controller, LED Tetra FX Special Lighting Effects Controller, Cat. No. GEFX 1 1. This product is suitable for only when connected to a Class 2 power source or ISP, Model GEXLPS20, GEXLPS21, GEXNOS30 or GE)<NPS31 by GE Rated Input is 12/24 V dc, Output is 12/24 V dc. 2. This product is a Class 2 device suitable for use in dly. damp and wet locations. 3. The controller shall be provided in a suitable howsing when use in wet locations. 4. Lead wires are R/C (AVLV2), Style 2651, rated 1 05 C, 300V. Not suitable for use inside walls, above ceiling or othef similar concealed spaces unless mounted inside an electrical enclosure. 5. The cohtroller is provided with a DMX 5-pins input connector. The pin arrangements in the connector shall always be the same. The DMX controller is capable of providing the 4 channel dimming, flashing, chasing, sequencing, color mixing, and color changing functions. LED wire. Cat. No. GExxSWx. Nomenclature for Splice Connectors, LED'Wires, End Caps: xx denotes product line, CL = channel letter, DS = double sided, XL = leta long strip, PT = power tetra, XN = Exposed Neon, TM = Mini, MX = Max, TU = Ultra, PG = Power Grid, PX = Power White XL, PH = Power White HO, XH = Power White XL HO, MM = Mini Max; 'x' denotes design revision number. 1. These products are only suitable for connection to a Class 2 power source. 2. When units are connected to a Class 2/"LPS" circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2/"LPS" supply. 3. These products are suitable for use in dry, damp and wet locations. 4. These products described in this section may be cut into segments per manufacture insulation instr.uctions. 5. Units may be provided with UYMR2,3M type VHB double-sided adhesive tape. Tape must be utilized per UYMR2 "Conditions of Use" as defined in the Sign Components Manual. 6. The Light Guide has not been evaluated as an LED Strip Light enclosure or diffuser. Suitability shall be determined in the end use product. LED power supplies, Mode[s GECLPS4. 1. LED power supply, Catalog No GECLPS4 for dry and damp locations. 2. Each power supply output is Class 2. LED power supplies, Models GECLPS4D. 1. LED power supply, Catalog No. GECLPS4D for dry and damp locations. 2. Each power supply output is Class 2. LED power supplies, Models GECLPS6 and GECLPSPHA. 1. LED power supply, Catalog No. GECLPS6 for dry and damp locations. 2. Each power supply output is Class 2. LED power supplies, Models GECLPS3. 1. LED power supply. Cat. No GECLPS3 for dry and damp locations. 2. Each power supply output is Class 2. LED power; supplies, Models GECLPS5, GECLPSPH, GECLPSPW, GECLPSWH. 1. LED power supply, Cat. No. GECLPS5, GECLPSPH, GECLPSPW and GECLPSWH for dry and damp locations. 2. Each power supply output is Class 2. Power supplies with Class 2 outputs, Models GEPS24-80, GEPS12-60, GEPS24-20. 1. These components are intended for use in dry locations only when not potted. When potted, they are suitable for damp locations. 2. These Power supplies need to be installed in an enclosure with a means for the connection to conduit. 3. When a Temperature Test is required of the power supply installed in an enclosure because the enclosure measures less than 13.5 by 6 by 4 inches, the maximum temperature on the output transformer by thermocouple is 110°C. Similarly, for Model Ocfober 1, 2013 SIGN COMPONENTS MANUAL (SAM) 54 GEPS24-20, a temperature test is required when installed in an enclosure smaller than 13.5 by 6 by 4 inches, but the maximum temperature on the output transformer by thermocouple is 90°C 4. The output of these LED power supplies with Class 2 are acceptable for use in·a damp and wet locations. Power supplies with Class 2 outputs, Model GEXNPS30. 1. This component has outputs that qualify as being Class 2. 2. These components are intended for use in dry location ohly. 3. The itransformer employs a Class B (130) Insulation System. 4. These components shall be installed in compliance with the enclosure and mounting requirements of the ultimate application. 5. The maximum room ambient temperature permitted by the manufacture is 50(C. 6. A Temperature Test is required of the power supply installed in an enclosure that measures less than 13.5 by 6 by 4 inches. The maximum temperature on the output transformer by thermocouple is 110( C. Power supplies with Class 2 outputs, Models GEPS24-180U, GE 180/MVA/24T1 -C 1. The maximum measured output voltage, current and power at the output of these models was found in compliance with the limits for LPS output requirements and additionally evaluated to comply with Class 2 output criteria. 2. The transformer employ Class B insulation system. 3. Power Supply is intended for use in indoor Dry and Damp location only. 4. In the end product, power supply spacing to other heat producing components shall be minimum Pinches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure Adjacent power supplies shall be spaced at least 1 in.;end to end and 4 in. in any other direction 5. Input and Output leads are style 1316, rated 600 V, 105°C, VW-1. Minimum No. 18 AWG. The suitability of input and output connections shall be determined in each end use application. 6. The power supply was submitted and tested for a maximum ;manufacturer's recommended Tc point described in the table below. If adjacent LED power supplies are spaced closer than 1 in. end, to end or 4 in. side to side a temperature test shall be conducted in the end use product. Model Input Voltage. HZ Max. Case Ternp @ Tc, 'C Ambient 'C i GE180/MV/V24T1-C, GEPS24-100-277,60 80 60 180U LED Light Engine, Cat. Nos 1 110-WH-ZZ-TTK, 1110-RD-ZZ-TTK, catalog numbers where: "ZZ" representing assembly versibn: followed by: "TT" - Optional - represents the color temperaturei of the LEDs in degree "K" Kelvin. Cat. Nos. 1111 XX-ZZ-Y-TTK. catalog numbers may vary per nomenclature.: "XX" representing color: R[) RC, YG, GL, SB, BL, WH, YA, VVW, GR, PO; "ZZ" fepresenting assembly version: "Y" representing number of LE)s; followed by: "TT" - Optional - represents the color temperature of the LEDs in degree "K" Kelvin. 1. These products are only suitable for connection to a Class 2 power source. 2. When units are connected to a Class 2/"LPS" circuit, they are n0t to draw a total wattage of greater than the secondary or output rating of the Class 2/"EPS" supply. 3. These products are suitable for use in dry, damp and wetlocations. 4. The suitability of the LED Light Engine mounting means shall be determined inlthe end-ose application. 5. The suitability of the LED Light Engine to be used without an additional electrical enclosure shall be determined in the end-use application. 6. These products described in this section may be cut into segments per manufacture insulation instructions. 7. Units may be provided with UYMR2,3M type VHB double-sided adhesive tape. Tape must be utilized per UYMR2 "Conditions of Use- as defined in the Sign Components Manual. LED Driver with Class 2 Output, Models GEPS1'20-60U, GEPS24D-80U. 1. These LED Drivers have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 output. 2. These products are provided with thejollowing elear-ical ratings: Model No.Input Voltage (V Input Reg Input Curfent Output Voltage Output Curreht Output ac) (HZ)(A)(V dc) (A) Power (W) GEPS24D-80U 100-277 50/60 1.1 24 3.3 - 80 GEPS 12D-60U 100-277 50/60 0.85 12 - 5.0 3 --60 3. The load powered by the Class 2 output of the LED drivers are suitable for use in dry, damp and wet locationi 4. In the end product, LED driver spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 5. In the end product, LED Drivers shall be located not less than 1 inch (25.4mm) apart when arranged end-to-end, and not less than 4 inches (102mm) apart when arranged otherwise. 6. These products shall be enclosed in the end product. 7. The unit is intended for being used in permanently wired signs. 8. The suitability of output leads, rated No. 24 AWG minimum, rated 80°C minimum, 600 V, shall be determined in end product use. 9. These units may provided with Dimming Input (Purple and Gray wires) to control output cur.rent range, the suitability shall be determined in each end-use application. 10. These products are intended for use in dry and damp locations LED Driver with Class 2 Output, Model 1110PS-60S. 1. These LED drivers have been evaluated using resistive load resulting in the electrical input and output noted on page 1. 2. These LED drivers are provided with Class 2 output. 3. These LED drivers are intended to be operated in a maximum ambient (Ta) noted as below: -_ Model | Ta (°C) LD-60-UV-1214V 1 46 4. These LED drivers are intended fofuse in dry and damp locations except that models LD-60-UV-1214\/ and LD-60-UV-1214\/- SC are suitable for dry location only. 5. These LED drivers are provided with 18 AWG AWM input and output leads. The suitability of the wiring and the need for a suitable enclosure shall be considered in the end product. 55 SIGN COMPONENTS MANUAL (SAM)October 1, 2013 6. These LED drivers are intended to be operated on a maximum 20 A branch circuit. 7. The need of the grounding means shall be determined in the end product. 8. These LED drivers shall be enclosed within a suitable end product enclosure. 9. For model LD-60-UV-24V-DIW, the conduit knockout test was not conducted. The suitability is to be determined in end product. 10. In; the end product, LED driver spacing lo other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 11. In the end product, LED Drivers shall be located not less than 1 inch (25.4mm) apart when arranged end-to-end. and net less than 4 inches (102mm) apart when arranged otherwise. LED Driver with Class 2 Output, Model GEPS 12-180U. 1. The output (Red/Black) of each unit complies with Class 2 criteria of UL 1310. 2. The device is provided with 18 AWG input and output leads. Tbe suitability of input and output connections shall be determined in end-use application. 3; The suitability of grounding means sh'all be determined by end product. 4. The device is not intended for field wiring used. 5. The device is intended to be connected to a maximum 20 A branch circuit. 6. The devices are of the constant current type that requires the proper number of LED modules and controllers that does not exceed the maximum output voltage/current. 7. The measured maximum external enclosure temperature (Tc) is 77.2 degree C when the room ambient temperature are 60 degree C. The suitability shall be determined in end application. 8. The devices employ input surge suppression protection, Cat. No. S14K385E2K1 under UL File E321126, which is intended end- use SPD type 2. The suppressed voltage rating is 385 Vac. The suitability ofuse of this, component shall be determined ih the end-product application. 9. No mechanical test has been conducted for the models and the metal chassis is considered as dead metal. The devices shall be mounted in the intended manner in an enclosure, having adequate strength and thickness with acceptable. spacing being pmvided. 10. The device has been evaluated for dry and damp locations use only. 11. In the end product. LED driver spacing to other heat producing Lcomponents shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure 12. In the end product, LED Drivers shall be located not less than 1 inch (25.4mrn) apart when arranged end-to-end, and not less than 4 inches (102mm) apart when arranged otherwise. LED Driver Extended Enclosure, Model No. GEPSJ[360. 1. The J-Box extended enclosure has been evaluated only for use and connection to LED Class 2 Drivers Models GEPS12-60, GEPS 120-60U. GEPS24-80, GEPS240-80U, GEPS12-60U-NA, GEPS12-60U-GL, GEPS24-100U-NA, and GEPS24-1004- GL.2. These products complete the electrical enclosure when installed over the primary wiring of the LED driver. 3. The suitability of the mounting shall be determined in end use application. 4. The enclosure has been evaluated only for use in Dry and damp locations only 5. Supply connection shall be determined in the end used application. 6. Ground Screw size is No. 6 thread forming screw with cupped washer is provided for grounding. The maximum size ground wire that can be used is 14AWG. The maximum size branch circuit that the units can be connected to is 15A unless a 16- 14AWG six inch pigtail lead supplied by sign company is connected to ground terminal and then spliced to 12AWG ground wire of a 20 A branch circuit. 7. Cover Screw shall not be'of a thread forming or self-tapping type. 8. To keep the enclosure from rotating, the Enclosure shall be secured by at least one mechanical fastener. 9. The J-box has been evaluated ifor an ambient of 40°C. 10. The J-box label shall be marked for a 75°C supply wire connection. LED Driver with Class 2 Output, Cat. Nos. GEPS12-BOU-NA: GEPS12-60U-GIL GEPS24-100U-NA and GEPS24-100U-GL. 1. These power supplies are p-rovided with Class 2 outputs 2. These products with Class 2 outputs are suitable for use in dry and damp locations. 3. Model Nos. GEPS12-BOU-NA, GEPS12-60U-GL have been tested in an oven at max. 40°C ambient and Model Nos. GEPS24- 100U-NA, GEPS24-100U-GL in an over at max. 55 °C. Maximum case temperature at (Tc) for all models should not exceed 85°C. 4. The suitability of grounding connection shall be determined in the end-use product. 5. These products shall be enclosed in the end product. 6. These products are provided with the following electrical ratings: Model Input, 50/60 Hz Rated Output V A V DC A DC W GEPS12=60U-NA,120-277 Max. 0.65 12 5.0 60GEPS12-60U-GL, GEPS 12-60U-NA,120-277 Max. 1.10 24 4.0 96GEPS12-60U-GL 7. These products are suitable for factory wiring only. 8. In the end product. power supply spacing to other heat producing components shall be at least 25.4 mm (1 in.) from end to iend, and 101.6 mm (4 in.) from side to side. 9. The suitability of inpuUoutput leads and the wring shall be determined in end product use. 10. These LED drivers are intended to be operated on ai maximum 20 A branch circuit. 11. These products shall be enclosed in the end product. LED Driver with Class 2 Output, Model GEPS24-180U-GL. 1. The device shall be used within Recognized ratings as specified above. 2. Each output of the unit complies with Class 2 criteria of UL 1310. Multiple output units may exceed Class 2 when the output terminations are interconnected. Do not interconnect output terminations. 3. The device is provided with 18 AWG inpot and output leads. The strain relief test was not conducted on this device. The suitability of input and output connections shall be determined in end-use application. October 1, 2013 SIGN COMPONENTS MANUAL (SAM) 56 4. Temperature Test has been conducted using resistive loading, and the LED Driver was mounted on a heat sink. aluminum, approx. size 500 mm by 300 mm by 100 mm. The measured maximum external enclosure temperature (Tc) is 79.4 °C when the room ambient temperature is 60 °C. The suitability shall be determined in end application. 5. Transformers employ Class 130(B) insulation system. 6. The suitability of grounding means shall be determined by end product. 7. Thedevice is intended for factory installation only 8. The device is intended to be connected to a maximum 20 A brahch circuit. 9. The devices are of the constant current type that requires the proper number of LED modules and CQntrollers that does not exceed the maximum output voltage/current. 10. The device.has been evaluated for dry and damp location use only. GEMINI INC E16382 103 MENSING WAY CANNON FALLS, MN 55009 Plastic Channel Letters, Cat No Plastic Channel Letters, 1. The channel letters may be used as an electrical enclosure when provided with sign face material in the end-use application that is suitable for electrical enclosure use 2. The neon tube shall be spaced a minimum of 1 /8 in. from the inside walls ofthe plastic enclosure, and 1/8 in. from the sign face. 3. Openings for drain holes, conduit, electfode receptacles and mouhting shall be pr0vided in accordance with-the Standard. 4. The channel letter plastic is rated 80°C. 5. For outdoor or indoor use. 6. Spacings from the channel letter to the enclosure for neon transformers or power supplies shall be in accordance with Standard UL 48. Plastic Channel Letters, Plastic Indoor Channel Letters. 1.The channel letters have been evaluated for indoor application only. 2.The neon tube shall be spaced a minimum of 1/8 in. from the inside walls of the plastic enclosure, and 1/8 in. from the sign face. Openings for conduit, electrode receptacles and mounting shall be provided in accordance with the Standard. 3.The channel letter plastic is rated 50-C. 4. The channel letter may be used as an electrical enclosure when provided with a sign face material in the end-use application that is suitable for electrical enclosure. 5. Spacings from the channel letter to the enclosure of neon transformers or power supplies shall be in accordance with Standard UL 48. Plastic Channel Letters and Face, Plastic IndoofEChannel Letter Sign Body and Face 1. The channel letters have been evaluated for indoor application only. 2. The channel letters are not suitable as an electrical enclosure. 3. The channel letters are suitable for Class 2 LED and neon applications. 4. The channel letter plastic is rated 50'C. 5. Openings for conduit, electrode receptacles and mounting shall be provided in accordance with the Standard. 6. The neon tube shall be spaced a minimum of 1/8 in. from the inside walls of the plastic enclosure, and 1/8 in. from the sign face. 7. Spacings from the channel [etter to the enclosure of neon tcansformers or power supplies shall be in accordance with Standard UL 48. Aluminum reinforced thermoplastic signqface trim, Type Gem Brand. 1. These trim materials are used to secure a rigid thermoplastic sign face to an outdoor or indoor sign. 2. The ability of the trim to exclude water from contacting live parts needs to be evaluated in the end product. 3. Minimum No. 8 sheet metal screws need to be provided for securing the trim to the sign body. The maximum spacing between screws shall not exceed 18 in. and no fewer than four screws are to be used per face. 4. These products do not comply with enclosure requirements. 5. The following are among the items to be considered in the end-use application. 1. Acceptable for use in wet locations. 2. Water exclusion must be determined in the end product. 3. Minimum 5 cm (2 in.) spacing from heat producing components required. 4. The specified solvents are continuously applied to edge of acrylic or polycarbonate sign face, Additional specified adhesives may be applied for the final bond. Sign Face Generic Material Solvent Final 8ond Adhesive Aign Trim Generic Material Methyl Methacrylate Weld-On #4 or Weld-On #16, Weld-On Cellulose Acetate Butyrate (Acrylic) (Methylene Chloride )#58 (Polycarbonate)Weld-On #4 or Weld-On #58, Lord Cellulose Acetate Butyrate Methylene Chloride Adhesive #7550 Plastic Channel Faces, Type Gemini Gemlite Channel faces and Gemihi Edge Glo faces 1. The sign faces have been evaluated for indoor & outdoor applications. 2. The sign faces are not suitable as an electrical enclosufe. 3. The sign face plastic is rated 50°C. 4. The sign face for channel letter is not to be considered as providing a weatherproof enclosure„therefore all internal components shall be suitable for outdoor use or shall be completely enclosed and protected from weathering. 5. The neon tube or LED shall be spaced a mihimum of 1/8 in. from the inside walls ofthe plastic enclosure, and 1/8 in. from the sign face. 6. The sign face may be used with either plastic or metal channel letters. Plastic Channel Letters, Type Ihdoor, outdoor designated "GEMINI FORMED SIGN BODY" for Class 2 powered LED modules strips. 1. These products are only suitable to house LED modules strips that are powered by UL Listed or FUC Class 2 Power Supply rated max 30 VDC or max 15 VAC. 2. These products are not suitable for use as electrical enclosures. GE Tetra® PowerMAX IMaximum Performance IMinimizes Costs Tetra® PowerMAX is the remarkable LED System designed for large channel letters. Working closelg with sign builders and owners, we've designed a lighting solution that provides outstanding uniformity with less product to help you save on installation and material costs. The OptiLens™ Difference OptilensM maximizes LED performance by capturing otherwise wasted light and redirecting it towards the illuminated surface to create an exceptionally uniform channel letter. This unique lens technology optimizes each LED to allow for wider stroke spacing, which helps reduce the amount of material needed in each sign. In addition, OptiLens helps protect the LED against moisture, humidity, damage and corrosion. Optilens™ creates a wide viewing angle, maximizing light coverage area while protecting the LED Can cut between any modules Overmolded design protects components from moisture, damage and corrosion Pre-drilled hole makes mounting easy Continuous wire through LED module uses IDC connectors vs. soldering for maximum strain relief Industrial-grade mounting tape for greater installation convenience " Help your customers protect their brand image with o uniform lit sign that performs flawlessly for years. When you use Tetra PowerMAX in your large channel letters, you enhance your good name as well as theirs. Building GE Reliability into Every Sign Reliability matters.That's why we rigorously test our designs, components, products and processes (including high temperature, high-humidity and accelerated life testjng) to ensure that every Tetra PowerMAX LED lighting sgstem performs brilliantly for years. r. -*· Wider Stroke Spacing with Exceptional Uniformity New, super-efficient Tetra PowerMAX stretches stroke spacing to an impressive 11 inches in a 5-inch depth channel letter without sacrificing on uniformity! When following our recommended logout guidelines, sign OEMs can cut the number of LED modules in half and still maintain exceptional uniformity across the sign face. You need to see it to believe it. Components SKU GEWHPMTL5 GEWWPMTL5 GEWWPMTL5-50K GEWWPMTL5-41K GEWHPMTL5WD GEWWPMTL5WD 9409 191600041 192160005 Description Tetra® Power MAX, 7100K, 5 LEDs/ft (-16 LEDs/mil Tetra® PowerMAX, 3200K, 5 LEDs/ft (-16 LEDs/m) Tetra® PowerMAX, 5000k, 5 LEDs/ft (-16 LEDs/m) . Tetra® PowerMAX, 4100K, 5 LEDs/ft (-16 LEDs/m) Tetra® PowerMAX, 7100K, 2 Module Sample Tetra® PowerMAX,;3200K, 2 Module Sample 18 AWG Supply Wire (0.82 mm9 22-14 AWG Twist-on Wire Connector 10.33-2.08 mm21 22-18 AWG In-Line Splice Connector (0.33-0.82 mmz) Package Quantity 100 ft (30.48 m)/box (150 modules) 100 ft (30.48 m)/box (150 modules) 100 ft (30.48 m)/box (150 modules) 100 ft (30.48 m)/box (150 modules) 1 sample 1 sample 500 ft. (152-40 m)/spool 500/bag 500/bag CURnicol-EJEFEIZE] Typical Typical Brightness Brightness Wavelength LEDs/Modules/Power Supply Viewing Color (lumens/module)(lumens/ft.)Color Temp.Module Foot Loading 60W Angle Tetra® PowerMAX White 121 182 7100K 3 1.5 25 ft. (38 modules)150° Tetra® PowerMAX Warm White 95 143 3200K 3 1.5 25 ft. (38 modules)150° Specification Item Cuttino Resolutioh LED Strip Operatihg Environment Tetra® PowerMAX Energy Consumption Power Supply Maximum Supply Wire Limits, Module Dimensions Sign Dimensions Limited Warranty System Certifications Specification Cut between any module -40 °C to +60 °C Strip: 1.56 W/module, Sustern: 1.87 W/module GEPS12-20 Input 90-264VAC,Output 12VDC GEPS12-60 Input: 90-264VAC,Output 12VDC GEPS12-60U Input: 108-305VAC; Output 12VDC GEPS12D-60U Input: 90-305VAC; Output 12VDC GEPS12-180U Input: 90-305VAC: Output 12VDC GEPS12-60,60U GEPS12D-60U GEPS12-180U GEPS12-20 Supply Wire Gauge 30 ft. (9.14 m)120 ft. (36.6 m)18 AWG {0.82 mmz),supply wire-9409 50 ft.(15.24 m)16 AWG (1.31 mmz) supply wire 80 ft. (24.38 m)14 AWG (2.08 mm2) supply wire 120 ft. (36.58 m)12 AWG (3.31 mmz) supply wire Wiring to be installed in accordonce with Article 725 of the National Electric Code (NEC). 0.31 x 3.94 x 0.71 in. (8 x 100 x 18 mm) For best results, recommended sign depth is 4 inches (102 mm) or greater GE offers a limited system warrantgof up to five (5) years UL Recognized #E219167, UL Classified #E229508, CE, C-tick, RoHS, IP66 rated: separate enclosure required, damp location rated ./0 I 4CWUS .®us C€09 4 GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com 1-888-69-43-533 GE Ughtirig Solutions. LLC is o subsidiary d the General Electric Company. Tetro is o trodemork of GE lighting Solutions, LLC. The GE biond ond logo ore trademarks of the General Electric Compony. © 2011 GE Lighting Solubons, LLC. Information provided issubjectto change withoutnotte. All voluesore design or typicol volueswhen meosured under loborotory conditiona SIGN1O1-R092911 t 1 U l\€ L.> li- 3 00 ( 4--21 c>7 8 %© t. 11 required or the dedicated circuit breakerIAustA local disconnect for the monument sigfo individually lockable in the off position. ia witn a , ,-12-inchwalkway. ucw ...City of Santa Ana Planning & Building Agency ELECTRICAL 2134 PLAN APPROVAL 14 Thls set of plans and spedfica#ons must be kept on 1| the job at all times and It Is unlawful to make any changes or alterations on same without written per- I mission from the Department of Bunding Safety City of Santa Ana. The approval of this plan and speclflcatlons SHALLi NOT hs teld to permit nor be an spproval of theviolaMr any provisions of ANY City Ordhiance I or Stale Law. 59£00.6Access to any power supply ill attic or aboveceiling shall be immediately from a ladder or- 9 v 3 foot access door & passage witi-r-r AnO-21 (d)(d) loG City of Santa Ana. CBC & CEC 2010 Minimum (4) screws per letter, maximum 24" on center, 2 penetration, #10 sheet metal screws, & 0 W drain holes_per letter PERMITTYPE:E T PLBG MECH GRADING : PERMIT# |0..Iit) j 58, OCC. GROUP gill«Zq rip CONSTR. TYPE : CODE EDiTION 520 rE) FLOOD ZONE 3< Approuer==iD- 144*FLOOD ZONE CER'TIE REQ'D YES /Ne-7 MICROFILM YES -7 CITY OF SANTA ANA RADIANT BARRIER @ ROOF YES , DEPARTMENT OF BUILDING SAFETY 1 RESIDENTIAL DEV. FEE- YES ( 1 SCHOOL DISTRICT YES\&12 0 NO El 8 Site Plan 1 i 3 Sign Location Office:I'llififillq M /44 r*€a t€tdalili 714-751-5778 714-356-8893 E-mail www.speedqualitysigns.com info@speedqualitysigns.com Lic. #873011 Address: 2021 5. Eastwood Ave, Ste C Santa Ana Ca 92705 Design - Fabrication - Installation Project: Subway Approval Signatures Location: 600 S. Grand Ave #106, Santa Ana Ca Client: Contact: Sonny Sales&Date: 9/5/13 Design SQS Job# 000029 Landlord: .. - q GRAND COMMERCE CENTER M SUBWAy GRAND COMMERCE CENTER Side 2 Office: 714-751-5778kiltER)£.-@tf Cell:714-356-8893 E-mail: www.speedqualitysigns.com info@speedqualitysigns.com Lic.#873011 Address: 2021 S. Eastwood Ave, Ste C Santa Ana Ca 92705 posign--Facition - Installation Approval SignaturesProject: Subway Location:600 S. Grand Ave #106, Santa Ana Ca Client: Contact: Sonny Sales&SQSDate: 9/5/13 Design Job# 000029 Landlord: 1 25'-0" Sign A 8'-9" 108" 18"111.11 4 Office: V./1-140'VDo'l 714-751-5778 22 Cell: 714-356-8893 E-mail: www.speedqualitysigns.com info@speedqualitysigns.com Lic. #873011 Address: 2021 S. Eastwood Ave, Ste C Santa Ana Ca 92705 0 Project: Subway Approval Signatures Location: 600 S. Grand Ave #106, Santa Ana Ca Client: Contact: Sonny Sales &Date: 9/5/13 Design SQS Job# 000029 Landlord: Sign B I 124" 16" 11"./Ill.*-SUBWAY ./Ii \// 6 04 Specifications: CD.080 Aluminum panell" deep painted Green Polyurethane enamel finished. ® "Sub"to be 1 /2" PVC cut out letters painted white. @ "Way"to be 1/2" PVC cut out letters painted Yellow. Panel to be mounted to existing Monument sign with angle brackets. @@ 1. Aluminum panel. 2. 1/2" PVC letters. 3.1/4"angle brackets. 4. Existing Monument. Office: t>22<E,50*ZAQI_714-751-5778SIIUOUZ Cell:714-356-8893 E-mail: www.speedqualitysigns.com info@speedqualitysigns.com Lic. #873011 Address: 2021 S. Eastwood Ave, Ste C Santa Ana Ca 92705 Project: Subway Approval Signatures Location: 600 S. Grand Ave#106, Santa Ana Ca Client: Contact: Sonny Sales &Date: 9/5/13 Design SQS Job# 000029 Landlord: -Ill- IC-t Sign A i 8'-9" 1.5" 1 2 3 1 /77771-77T S 18" 15.5"4 viv 1 €-1'l'1AI. 1lei -0 @ ® Side view1 CO Z1 _Ispecification< l IO 3" C al 0.080 aluminum routed Quttontout panel 30 deep to painted dark green. Z nol *"Sub" W be 14"wHite Scrylic pulli tbru letters.0 0 #3< £*"*by" ibbe.lh"whlte act)lic push thru lettersU,1 0 Al 1- .1/2"push thru acrylic.%= 52 21'1 q j wit ap,Plied 3:0#3630£01-5 transluq¢nt*llowvinyl film. ,/4 0 -1 q/1 68 .12vdc LED light unitIg1y . Deep aluminum return. W- D - A JU.9 1 02 6 % 6 f *Ma ® A =r' _ 5. non-ferous fasteners and anchors 30:, ' a: 10 0 · spacing: 3,5 units/stroke inch.A 9 1 6 4 1 .4 74 :1 - 1.? R .;C L 1 - 11,1 L, 4, Disconnect switch 1 .2 Al .:. 1 -,I. t--0 four(4) per character and screws 1/40 x 4"long & spacers . UL listed power supply, 12-500 watt as needed. . UL Listed 18AWG wire. . Existing wall. . Drain hole. i 0:U1 1. tf lu £5 i 111 LL. 2 2 65 EUl EL '0000 CD .lASTER I.D.6 ®7 8 9 Office: 714-751-5778 2UJULW©Cell: 714-356-8893 E-mail: www.speedqualitysigns.com info@speedqualitysigns.com Llc.#873011 Address: 2021 S. Eastwood Ave, Ste C Santa Ana Ca 92705 LETTER SECTION Project: Subway Approval Signatures Location: 600 S. Grand Ave #106, Santa Ana Ca Client: Contact: Sonny Sales &Date: g/5/13 Design SQS Job# 000029 Landlord: 1 '.