Loading...
HomeMy WebLinkAbout1834 W Third St #3 - PlanGreen Hill Remodeling Inc. 7020 Middlesbury Ridge Cir. | West Hills, CA, 91307 | p: 310.667.1154 | CSLB#: #938682 / B, C-46 Project Name: Andy Mai; 1834 W 3rd St., Santa Ana, CA 92703 (Main House & ADU) Date: 11/19/25 Dear Plan Checker, This letter is to authorize Green Hill Solar to pull permits for the solar projects for the main house and ADU located at 1834 W 3rd St., Santa Ana, CA 92703, to install solar panels. NAME:________________________ SIGNATURE:___________________ DATE SIGNED:_________________ Docusign Envelope ID: 855054AF-EC83-47DC-AB94-76281E3B46B8 12/22/2025 Andy Mai Certificate Of Completion Envelope Id: 855054AF-EC83-47DC-AB94-76281E3B46B8 Status: Completed Subject: Complete with Docusign: 1834 W 3rd St_CUSTOMER AUTHORIZATION LETTER.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 4 Initials: 0 Simon David Sayag AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 7108 De Soto Ave 101C Los Angeles, CA 91303 Sales@greenhillsolar.com IP Address: 97.167.16.252 Record Tracking Status: Original 12/22/2025 2:18:35 PM Holder: Simon David Sayag Sales@greenhillsolar.com Location: DocuSign Signer Events Signature Timestamp Andy Mai andytm310@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 76.170.3.212 Signed using mobile Sent: 12/22/2025 2:21:20 PM Viewed: 12/22/2025 2:41:02 PM Signed: 12/22/2025 2:41:06 PM Electronic Record and Signature Disclosure: Accepted: 12/22/2025 2:41:02 PM ID: c86be15f-87aa-4295-9d5f-aeb78b3818f0 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 12/22/2025 2:21:20 PM Certified Delivered Security Checked 12/22/2025 2:41:02 PM Signing Complete Security Checked 12/22/2025 2:41:06 PM Completed Security Checked 12/22/2025 2:41:06 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, Idan David Edery (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after the signing session and, if you elect to create a DocuSign account, you may access the documents for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Electronic Record and Signature Disclosure created on: 8/9/2022 1:31:13 PM Parties agreed to: Andy Mai Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact Idan David Edery: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: Sales@greenhillsolar.com To advise Idan David Edery of your new email address To let us know of a change in your email address where we should send notices and disclosures electronically to you, you must send an email message to us at Sales@greenhillsolar.com and in the body of such request you must state: your previous email address, your new email address. We do not require any other information from you to change your email address. If you created a DocuSign account, you may update it with your new email address through your account preferences. To request paper copies from Idan David Edery To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an email to Sales@greenhillsolar.com and in the body of such request you must state your email address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with Idan David Edery To inform us that you no longer wish to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your signing session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an email to Sales@greenhillsolar.com and in the body of such request you must state your email, full name, mailing address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found here: https://support.docusign.com/guides/signer-guide- signing-system-requirements. Acknowledging your access and consent to receive and sign documents electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to an email address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format as described herein, then select the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm that:  You can access and read this Electronic Record and Signature Disclosure; and  You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and Disclosure to a location where you can print it, for future reference and access; and  Until or unless you notify Idan David Edery as described above, you consent to receive exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you by Idan David Edery during the course of your relationship with Idan David Edery. Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. Expedited Permit Process for PV Systems — Micro-Inverter 2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Micro-Inverter Site Plan             E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone:One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone:Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO-INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE.b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram COVER SHEET SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-1 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 SCOPE OF WORK SYSTEM SIZE: 5 x 435 = 2.18KW CEC AC: 2.03KW MODULES: (5) MISSION SOLAR: MSX10-435HN0B 435W MODULES MODULE MAX POWER (P/MAX): 435W INVERTER: (5) ENPHASE: IQ8MC-72-M-US @ (240V) MICROINVERTERS RACKING: IRONRIDGE XR10 RAIL ATTACHMENT: IRONRIDGE FLASHFOOT 2 VICINITY MAP ADU BUILDING INFORMATION: ONE STORY ADU TYPE OF CONSTRUCTION: V-B OCCUPANCY: RESIDENTIAL GROUP R - 3 APN# 00716318 ROOF TYPE: COMP. SHINGLES ROOF RAFTERS: 2"X6" @ 16" O.C. ELECTRICAL INFORMATION UTILITY COMPANY: SCE MAIN SERVICE AMPERAGE: 200A ARRAY TILT:ARRAY AZIMUTH: #1 - 26°#1 - 180° CODE SUMMARY THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA PLUMBING CODE 2020 NATIONAL ELECTRICAL CODE ALL OTHER ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGENCIES. TABLE OF CONTENTS PAGE #DESCRIPTION PV 1 COVER SHEET PV 2 SITE PLAN PV 3 ARRAY DETAIL PV 4 STRING LAYOUT PV 5-6 ATTACHMENT DETAIL PV 7 ELECTRICAL DIAGRAM PV8 ELECTRICAL CALCULATION PV 9 PLACARD PV 10+SPEC SHEETS GENERAL NOTES: ·LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. ·THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES ·PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED ·ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED ·ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703, UL1741 AND UL1703 ·ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT ·THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED ·THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS ·IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE, IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE ·EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" ·A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH CAL-OSHA REGULATIONS ·PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER, AND SYSTEM COMPLIES WITH 690.35. ·MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. ·INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. ·ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED, LABELED, AND INSTALLED PER THE NEC, THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. ·CONDUITS AND CABLES EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8" ABOVE ROOF SURFACE. NEC 310.15(B)(3)(c) ·THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTAND A MINIMUM 110 MPH WIND LOAD. LICENSED CONTRACTOR SIGNATURE: Simon Sayag 55'-0" 11 9 ' - 0 " 11 9 ' - 0 " 55'-0" MS P UM CB AC D SU B JB SITE PLAN SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-2 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 SITE PLAN: SCALE:- 1/16" = 1'-0" CB COMBINER BOX LEGEND MSP MAIN SERVICE PANEL UM UTILITY METER JB JUNCTION BOX ·FOR PHOTOVOLTAIC ARRAYS OCCUPYING 33% OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A MINIMUM 18" SETBACK IS REQUIRED ON BOTH SIDES OF HORIZONTAL RIDGE. CFC 605.11.2.2 (IRC R324.6.2) ·TOTAL SOLAR AREA: 105.05 SQFT. ·TOTAL ROOF AREA: 979 SQFT. ·TOTAL ROOF AREA COVERED BY SOLAR: 10.73% ACD AC DISCONNECT ARRAY PITCH AZIMUTH SOLAR AREA (SQFT) SOLAR LOAD (LBS) ROOF AREA (SQFT) ROOF AREA COVERED BY SOLAR # MODULES #1 26° 180° 105.05 234.80 979 10.73%5 2-STORY RESIDENCE 3/4" EMT CONDUIT RUN MIN. 7/8" ABOVE ROOF (N) JUNCTION BOX ON ROOF W 3RD ST EXISTING DRIVEWAY ROOF ACCESS POINT (E) ADU (E) 200A MAIN SERVICE PANEL, 240V (E) UTILITY METER ARRAY #1 (5) MISSION SOLAR: MSX10-435HN0B 435W MODULES (N) 30A AC DISCONNECT (N) 125A IQ COMBINER BOX MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 5 MODULES MODULE TYPE = MISSION SOLAR: MSX10-435HN0B 435W MODULES MODULE WEIGHT = 46.96 LBS / 21.3KG. MODULE DIMENSIONS = 67.79" x 44.64" = 21.01 SF UNIT WEIGHT OF ARRAY = 2.23 PSF SUB SUB PANEL N D A I S Y A V E PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E 1-STORY ADU 36" FIRE SETBACK (E) MAIN HOUSE (E) 100A SUB PANEL 36 " F I R E S E T B A C K 36 " F I R E SE T B A C K LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-3 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 ARRAY DETAIL # MODULES PER ARRAY ROOF TYPE ATTACHMENT ROOF HEIGHT FRAME MATERIAL FRAME TYPE FRAME SIZE OC SPACING AR-01 5 COMP. SHINGLES IRONRIDGE FLASHFOOT 2 1 STORY ADU WOOD RAFTERS 2"X6"16" O.C. LOAD CALCULATION ITEM #OR LIN FT WEIGHT PER (lbs) TOTAL WEIGHT (lbs) MODULES 5 47.0 234.80 RAILS 60.03 0.4 26.2 ATTACHMENTS 10 0.65 6.50 TILT LEGS 0 3.5 0 MICROINVERTERS 5 2.4 11.9 TOTAL WEIGHT 279.4 WEIGHT PER MOUNT 279.4 / 10 = 27.9 lbs/Mount lbs (N) IRONRIDGE XR10 RACKING SYSTEM MODULES: 5 MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 110 MPH 3-SEC GUST. LAG SCREWS: 5/16"x 2.5" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. DESIGN CRITERIA IRONRIDGE FLASHFOOT 2 ATTACHMENTS @ 64" O.C. AR-01 - SCALE: 3/16" = 1' PITCH: 26° AZIMUTH: 180° (N) 5 - ENPHASE: IQ8MC-72-M-US MICROINVERTERS2"X6" RAFTERS @ 16" O.C. 3' 3' 5'-4" TYP. LICENSED CONTRACTOR SIGNATURE: Simon Sayag CB AC D SU B JB SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-4 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 STRING LAYOUT (5) MISSION SOLAR: MSX10-435HN0B 435W MODULES (1) BRANCH OF 5 MODULES CONNECTED IN PARALLEL STRING LAYOUT: SCALE:- 3/16" = 1'-0"BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 5 MISSION SOLAR: MSX10-435HN0B 435W MODULES INVERTER 5 ENPHASE: IQ8MC-72-M-US @ (240V) MICROINVERTERS COMBINER BOX 1 125A ENPHASE COMBINER 4 BOX (X-IQ-AM1-240-4) WITH ENVOY COMMUNICATION GATEWAY AC DISCONNECT 1 AC DISCONNECT: 240V, 30A NON-FUSED NEMA 3R, UL LISTED ATTACHMENT 10 IRONRIDGE FLASHFOOT 2 RAILS 3 IRONRIDGE XR10 RACKING 168" RAIL SPLICE 2 SPLICE KIT MID CLAMPS 8 MID CLAMP END CLAMPS 4 END CLAMP GROUNDING LUG 1 W 3RD ST A-1 N D A I S Y A V E A-2A-3A-4A-5 LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-5 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 ATTACHMENT DETAIL 2 ATTACHMENT DETAIL (enlarged section view) PV-5 SCALE: NTS 1 ATTACHMENT DETAIL PV-5 SCALE: NTS SEE (2/PV-5) FOR ENLARGED VIEW PV MODULE (E) SINGLE LAYER OF COMP. SHINGLE 2"X6" RAFTERS @ 16" O.C. 5/16"x3-1/2" SS LAG SCREW THREADED TOP 1 LAG PER ATTACHMENT 2.5" MIN EMBEDMENT IRONRIDGE SOLAR RACKING UNIVERSAL END CLAMP (OR GROUNDING MID CLAMP) (N) IRONRIDGE XR10 RACKING SYSTEM FLASHING (E) SINGLE LAYER OF COMP. SHINGLE PV MODULE IRONRIDGE FLASHFOOT 2 ATTACHMENT 4" 2"X6" RAFTE R S @ 16" O.C. NOTE: 1. PRIOR TO COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFY THE FRAMING SIZES, SPACINGS, AND SPANS NOTED IN THE STAMPED PLANS AND ACCOMPANYING CALCULATIONS AND NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION. 2. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE PROPOSED PV INSTALLATION REFERENCED ONLY. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS MUST FOLLOW MANUFACTURER GUIDELINES AND REQUIREMENTS. 3. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR DETAILS REGARDING CALCULATIONS AS WELL AS LIMITS OF SCOPE OF WORK AND LIABILITY. LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-6 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 ATTACHMENT DETAIL EAST WALL 1 ELECTRICAL EQUIPMENT ELEVATION SCALE: NTSPV-6 3 SECURE FIRST END SCALE: NTSPV-6 4 GROUNDING DETAIL SCALE: NTSPV-6 UFO (80 IN LBS) STOPPER SLEEVE1" FROM RAIL END UFO GROUNDING LUG FAULT CURRENT GROUND PATH MINIMUM 10 AWG COPPER WIRE BOUDED SPLICE (RAIL CONNECTION) (N) 125A IQ COMBINER BOX (N) 30A AC DISCONNECT(E) 200A MAIN SERVICE PANEL, 240V (E) UTILITY METER 1 CONDUIT DETAILS SCALE: NTSPV-6 CONDUIT ABOVE ROOF TO LOAD CENTER/MAIN SERVICE EMT CONDUIT STRUT STRAP STRAIN RELIEF J-BOX RAIN TIGHT, STEEL EMT CONNECTOR CONDUIT SUPPORT WITH MIN 7/8" FROM THE ROOF PLANE (E) 100A SUB PANEL WEST WALL LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-7 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 ELECTRICAL 120% RULE - NEC 705.12(N)(3)(3) UTILITY FEED + SOLAR BACKFEED 100A + 8.31A = 108.31A BUSS RATING x 120% 100A x 120% = 120A (E) 100A SUB PANEL SERVICE INFO UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: SCE 240V N/A 2-100A & 1-200A WEST WALL MAIN CIRCUIT BREAKER RATING: UNDERGROUND 200A JUNCTION BOX 600V, NEMA 3R UL LISTED ENVOY IQ (REVENUE GRADE METER) EN S E M B L E W I R E L E S S CO M M U N I C A T I O N K I T CONSUMPTIONPRODUCTION CELL MODEM TO MAIN SERVICE PANEL 15A 20A ~ = ~ = BRANCH A 1 5 MISSION SOLAR: MSX10-435HN0B 435W MODULES (5) ENPHASE: IQ8MC-72-M-US (240V) (1) BRANCH OF (5) MODULES Q CABLE #12 AWG: - BLACK L1, RED L2 (1) #6 BARE COPPER GND (1 PER BRANCH)3/4" EMT CONDUIT (1) #10 AWG THWN-2 + Red (1) #10 AWG THWN-2 - Black (1) #8 AWG THWN-2 GND (N) 125A ENPHASE IQ COMBINER 4 BOX (X-IQ-AM1-240-4) WITH ENVOY COMMUNICATION GATEWAY (E) 100A SUB PANEL G BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V, 60Hz (E) 200A THREE GANG MAIN SERVICE PANEL, (E) UTILITY METERS M M 200A MB 100A MB (E) WIRING GROUNDING ELECTRODE SYSTEM 3/4" EMT CONDUIT (3) #10 AWG THWN-2 (1) #8 AWG THWN-2 GND (N) AC DISCONNECT: 240V, 30AMP NON-FUSED NEMA 3R, UL LISTED M 100A MB 20A (N) 20A BACKFEED BREAKER AT THE OPPOSITE END OF THE MAIN SERVICE BUSBAR FROM THE MAIN OVER CURRENT DEVICE. LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-8 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 AMBIENT TEMPERATURE SPECS AMBIENT TEMP (HIGH TEMP 2%) RECORD LOW TEMP 2° 31° CONDUIT HEIGHT 7/8" ROOF TOP TEMP 90° CONDUCTOR TEMPERATURE RATE 90° WIRING CALCULATIONS AC CONDUCTOR AMPACITY CALCULATIONS: FROM ROOF TOP JUNCTION BOX TO IQ COMBINER BOX AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT EXPECTED WIRE TEMP (°C): 31° TEMP CORRECTION PER TABLE 310.15: 0.96 #OF CURRENT CARRYING CONDUCTORS: 2 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 1.0 CIRCUIT CONDUCTOR SIZE: 10 AWG CIRCUIT CONDUCTOR AMPACITY: 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): 1.25 X MAX AC OUTPUT CURRENT X # OF INVERTERS PER BRANCH BRANCH A : 1.25 X 1.33 X 5 = 8.31A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15 TEMP CORR. PER NEC TABLE 310.15 X CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.96 X 1.0 X 40 = 38.4A AC CONDUCTOR AMPACITY CALCULATIONS: FROM IQ COMBINER BOX TO SUB PANEL EXPECTED WIRE TEMP (°C): 31° TEMP CORRECTION PER NEC TABLE 310.15: 0.96 CIRCUIT CONDUCTOR SIZE: 10 AWG CIRCUIT CONDUCTOR AMPACITY: 40A #OF CURRENT CARRYING CONDUCTORS: 3 CONDUIT FILL PER NEC 310.15(B)(2)(a): 1.00 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): 1.25 X OUTPUT CURRENT OF LOAD CENTER 1.25 X 1.33 X 5 = 8.31A DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.15: TEMP CORR. PER NEC 310.15 X CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.96 X 1.0 X 40 = 38.4A MICRO-INVERTER SPECIFICATIONS MANUFACTURER / MODEL #ENPHASE: IQ8MC-72-M-US NOMINAL OUTPUT CURRENT 1.33 AMP RATED OUTPUT POWER 320 VAC # OF PANELS x NOMINAL OUTPUT CURRENT 5 x 1.33 = 6.65A SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # VMP IMP VOC ISC MISSION SOLAR: MSX10-435HN0B 435W MODULES MODULE DIMENSION 33.31V 13.07A 39.56V 13.79A 67.79"L x 44.64"W x 1.37"D (In Inch) MODULE TEMPERATURE COEFFICIENT OF Voc -0.25%/°C LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-9 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 PLACARDS CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN 1834 W 3RD ST, SANTA ANA, CA 92703 IQ COMBINER BOX AC DISCONNECT PV ARRAYUTILITY METER & MAIN SERVICE PANEL W 3 R D S T ADHESIVE FASTENED SIGNS: ·THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. ·WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. ·ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] SIGNAGE FORMAT: ALL LETTERS SHALL BE CAPITALIZED, 3/8" WHITE LETTERING ON RED BACKGROUND, ARIAL OR SIMILAR FONT, NON-BOLD; REFLECTIVE, ON WEATHER- RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING) WILL BE USED; DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT. LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION LABEL LOCATION: CONDUIT, COMBINER BOX WARNING: PHOTOVOLTAIC POWER SOURCE WARNING ELECTRIC SHOCK HAZARD LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (E), CB DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 6.65 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS ! NOTICE PV SYSTEM COMBINER PANEL DO NOT ADD LOADS TO THIS PANEL LABEL LOCATION: LOAD CENTER [Only use when applicable for PV load center] TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN WARNING PHOTOVOLTAIC SYSTEM DO NOT RELOCATE THIS BREAKER LABEL LOCATION: POINT OF INTERCONNECTION [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER [To be used when inverter is ungrounded] ! WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION ! RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: PV SOLAR SHUTDOWN SWITCH NO MORE THAN 3FT FROM THE SWITCH SUB PANEL ! LABEL LOCATION: POINT OF INTERCONNECTION WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY WARNING! LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. MSP UM CBACDSUB JB LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-10 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 SPECS SHEET LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-11 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 SPECS SHEET LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-12 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 SPECS SHEET LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-13 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 SPECS SHEET LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-14 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 SPECS SHEET LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-15 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 SPECS SHEET LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-16 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 SPECS SHEET LICENSED CONTRACTOR SIGNATURE: Simon Sayag SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" Signature with Seal PROJECT NAME & ADDRESS PV-17 AN D Y M A I 18 3 4 W 3 R D S T , # 3 SA N T A A N A , C A 9 2 7 0 3 PH O N E # : N / A REVDATEDESCRIPTION REVISIONS CONTRACTOR INFORMATION GREEN HILL SOLAR INC 7020 MIDDLESBURY RIDGE CIR., WEST HILLS, CA 91307 CSLB 938682, C-46 (Exp 10/31/2025) PHONE: (888) 902-3551 SPECS SHEET LICENSED CONTRACTOR SIGNATURE: Simon Sayag Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1834 W 3rd St. Unit #3, Santa Ana, CA 92703 Green Hill Solar Inc. 938682 x x x x x x x x x x Simon Sayag solarplans7@gmail.com (747) 888-3709 11/19/2025 11/19/2025 RE: Structural Certification for Installation of Residential Solar ANDY MAI:1834 W 3RD ST, SANTA ANA, CA 92703 Attn: To Whom It May Concern Design Criteria Code 2022 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 110 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Eugene Munyanziza, P.E.Signed 11/19/2025 EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2026 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of Composition shingle roofing over roof plywood supported by 2X6 Rafters at 16 inches. The slope of the roof was approximated to be 26 degrees. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com Structural Letter for PV Installation Date:11/19/2025 Job Address:1834 W 3RD ST SANTA ANA, CA 92703 Job Name:ANDY MAI Job Number:251119AM Scope of Work Table of Content Sheet 2 Cover 3 Attachment Uplift checks 4 Roof Framing Check 5 Seismic Check and Scope of work Engineering Calculations Summary Code 2022 California Building Code (ASCE 7-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 110 mph Exposure C References NDS for Wood Construction Sincerely, Signed 11/19/2025 Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2026 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. projects@evengineersnet.com http://www.evengineersnet.com Wind Load Cont. 110 mph ASCE 7-16 Figure 26.5-1B C 1.0 ASCE 7-16 Sec 26.8.2 0.85 ASCE 7-16 Table 26.10-1 0.85 ASCE 7-16 Table 26.6-1 1.00 ASCE 7-16 Table 26.9-1 22.31 psf 26.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1,2e)Zone(2r, 2n)Zone(3e)Zone(3r) Fig. 30-3-2 GCp=-1.3 -1.7 -1.7 -1.8 Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-34.81 -45.52 -45.52 -48.20 GCp=0.6 Figure 30.3-2 P=qh(GCp)(γE)(γa)=6.59 Equation 29.4-7 Rafter Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachment max. spacing=5.3 ft 5/16" Lag Screw Withdrawal Value=266 lbs/in Table 12.2A - NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity=760 lbs Zone Trib Width Area (ft)Uplift (lbs)Down (lbs) Zone(1,2e)5.3 14.6 135.6 139.8 Zone(2r, 2n)5.3 14.6 174.1 139.8 Zone(3e)5.3 14.6 174.1 139.8 Zone(3r)5 14.6 183.7 139.8 Conservative Max=183.7 <760 CONNECTION IS OK Risk Category = KZ = Kd = Ke = 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. II V= Exposure = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift governs γE= γa= KZt = qh= 0.00256KzKztKdKeV2= Pitch = Lag Screw Penetration projects@evengineersnet.com http://www.evengineersnet.com Vertical Load Resisting System Design Roof Framing Rafters Snow Load Fully Exposed pg=0 psf Ct =1.1 Ce =0.9 Is =1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf Conservatively (Cs=1)0 plf Max Length, L =10.0 ft (Rafter maximum Allowable Horizontal Span) Tributary Width, WT =16 in Dr =10 psf 13.33 plf PvDL =3 psf 15.9 plf Load Case: DL+0.75(0.6W+S) 0.75(Pnet+Ps)+ Ppvcos(θ)+PDL=33 plf Mdown=415 lb-ft Mallowable = Sx x Fb' (wind)=975 lb-ft >415 lb-ft OK Load Case: DL+S Ps+ Ppvcos(θ)+PDL=29 plf Mdown=365 lb-ft Mallowable = Sx x Fb' (wind)=975 lb-ft >365 lb-ft OK Load Case: DL+0.6W Pnet+ Ppvcos(θ)+PDL=34.5 plf Max Moment, Mu=431 lb-ft Mallowable = Sx x Fb' (wind)=1357 lb-ft >431 lb-ft OK Pv max Shear=139.8 lbs Shear, Vu=wL/2+Pv Point Load =286 lbs Max Shear, Vu=wL/2+Pv Point Load =286 lb Member Capacity DF-L No.2 2X6 CL CF Ci Cr KF φ λ Fb =900 psi 1.0 1.3 1.0 1.15 2.54 0.85 0.8 1346 psi Fv =180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E =1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin =580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d =5.5 in Width, b =1.5 in Cross-Sectonal Area, A =8.25 in2 Moment of Inertia, Ixx =20.7969 in4 Section Modulus, Sxx =7.5625 in3 Allowable Moment, Mall = Fb'Sxx =847.9 lb-ft DCR=Mu/Mall =0.43 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A =990.0 lb DCR=Vu/Vall =0.29 < 1 Satisfactory Design Value Adjusted Value projects@evengineersnet.com http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf % or Roof with Pv 11% Dpv and Racking 3 psf Average Total Dead Load 10.3 psf Increase in Dead Load 1.3%OK Limits of Scope of Work and Liability The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans - ANDY MAI. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this Structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. projects@evengineersnet.com http://www.evengineersnet.com