HomeMy WebLinkAbout2502 S Artesia St - Plan (2)SCOPE OF WORK GENERAL NOTES VICINITY MAPABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N)NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX PAGE REV: D 12/5/2025 JUAN BELTRAN 2502 S ARTESIA ST, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-502BELT PR-3004162307 SHEET DESIGNER: PRAVEEN CUSTOMER RESIDENCE: TEL. (657) 272-3868 APN: 412-391-11 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 COVER SHEETREV NAME DATE COMMENTS B KYLE CARTER 9/15/2025 AHJ REDLINES • ALL WORK SHALL GENERALLY CONFORM WITH 2022 CBC/CEBC, 7-16 ASCE & 2018 NDS, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH CEC 2022. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH CEC 2022. • PHOTOVOLATIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A) • MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN SYSTEM IN COMPLIANCE WITH CEC 2022 690.12(B)(1) WHERE CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 13.96 AMPS MODULE SHORT CIRCUIT CURRENT. • 17.45 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a)(1) & 690.8 (b)]. • ENERGY STORAGE SYSTEM CONFORMS TO AND IS LISTED UNDER UL 9540. • ENERGY STORAGE SYSTEM LIVE PARTS ARE NOT ACCESSIBLE DURING ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). • ADDITIONAL DISCONNECTING MEANS SHALL BE INSTALLED WHERE THE CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER 706.15(D). • LISTED, COMBINATION TYPE AFCI SHALL BE INSTALLED WHERE BACKED UP CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). • ALL PASS-THROUGH CONDUCTORS MUST COMPLY WITH CEC 312.8 • THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) • SYSTEM SIZE: 13.77KW DC, 10.0KW AC • MODULES: (34) JA SOLAR: JAM54S31-405/MR • INVERTERS: (1) SOLAREDGE TECHNOLOGIES: SE10000H-USMN • ENERGY STORAGE SYSTEM: (2) FRANKLIN: APOWER XYYY 15KWH, 10KW INVERTER OUTPUT, LITHIUM IRON PHOSPHATE BATTERY (WEIGHT: 357LB EACH) • MICROGRID INTERCONNECT DEVICE: (1) 280A AGATE X CONTROL PANEL • RACKING: ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 • POWER-CONTROLLED SYSTEM (PCS) ENABLED EQUIPMENT INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS NEW 125A LOAD CENTER TO BE INSTALLED. PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-3.1 LAYOUT PV-3.2 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CONT. PV-4.2 ELECTRICAL CALCS PV-4.3 BACKUP LOADS CALCS PV-4.4 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE 2 PV-1.0 DD /ce/ PL PL PL PL PL PL PL PL PL PL PL PL PAGE REV: D 12/5/2025 JUAN BELTRAN 2502 S ARTESIA ST, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-502BELT PR-3004162307 SHEET DESIGNER: PRAVEEN CUSTOMER RESIDENCE: TEL. (657) 272-3868 APN: 412-391-11 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SITE PLAN NOTES: ·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: ·TOTAL ROOF SURFACE AREA: 2100 SQFT. ·TOTAL PV ARRAY AREA: 714.68 SQ FT. ·PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 = 34.03% ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. INTERIOR EQUIPMENT SHOWN AS DASHED FRANKLIN ENERGY STORAGE SYSTEM (ESS) COMMUNICATION WIRES GROUNDING ELECTRODE SE MP SM PM SP MAIN PANEL SERVICE ENTRANCE SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND WILL APPEAR IN SITE PLAN LC LEGEND ELECTRIC VEHICLE SUPPLY EQUPMENT ACREL METER IQ COMBINER BOX ENERGY STORAGE SYSTEMDC DISCONNECT(S) AC DISCONNECT(S) INVERTER(S) SOLAREDGE METER INV DC SUB-PANEL AC DEDICATED PV METER SUNRUN METER SEMPV LOAD CENTER EV AM CB BP BI 1BACKUP INTERFACE FRANKLIN APBOX BACKUP LOADS PANEL MD MICROGRID INTERCONNECT DEVICE GENERATION PANELGP BACKUP GATEWAYBG RDS REMOTE DISCONNECT SWITCH RAIL STANDOFFS & FOOTINGS SOLAR MODULES APB SITE PLAN - SCALE = 1/16"=1'-0" (E) RESIDENCE (N) ARRAY AR-01 (N) ARRAY AR-02 (N) ARRAY AR-03 (N) ARRAY AR-04 FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) S A R T E S I A S T (E) FENCE (E) GATE (TYP.) ROOF PATHWAYS (3' TYP) (E) CHIMNEY ROOF PATHWAYS (3' TYP) ROOF PATHWAYS (3' TYP) (E) SHED (TYP.) ACACLCINVAC MP SE RDS MDBP BB AAAAAABABAA AA BBBBB PV-2.0 CC BB CC CC CCC C C C (N) ARRAY AR-05 ARRAY PITCH TRUE AZIM PV AREA (SQFT) AR-01 18° 204° 105.11 AR-02 18° 204° 84.09 AR-03 18° 294° 378.41 AR-04 18° 24° 84.09 AR-05 18°24°63.07 DD Exp. 12/31/2026Digitally Signed On: 12/08/25 /ce/ DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 96 MPH 3-SEC GUST.FASTENERS: (1) 5/16" DIA S.S. LAG SCREW: 2.5" MIN EMBEDMENT INTO FRAMING PAGE REV: D 12/5/2025 JUAN BELTRAN 2502 S ARTESIA ST, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-502BELT PR-3004162307 SHEET DESIGNER: PRAVEEN CUSTOMER RESIDENCE: TEL. (657) 272-3868 APN: 412-391-11 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 LAYOUT 4" SOLAR MODULE SNAPNRACK RACKING MODULE ELEVATION DETAIL - SCALE: NTS D3 - AR-03 - SCALE: 1/8" = 1'-0" AZIM:294° PITCH:18° D4 - AR-04 - SCALE: 1/8" = 1'-0" AZIM:24° PITCH:18° •"EXISTING STRUCTURE IS ASSUMED TO BE A LIGHT-FRAME WOOD ROOF AND FREE FROM DAMAGE, DETERIORATION, OR MODIFICATION THAT WOULD COMPROMISE ITS ORIGINAL DESIGN INTEGRITY. CONTACT ENGINEER OF RECORD IF THE FOLLOWING MINIMUM REQUIREMENTS ARE NOT SATISFIED IN COMPLIANCE WITH THE STATED RACKING DESIGN: i: 2x WOOD FRAMING (NOMINAL) ii: FRAMING SPACING AT 24"" O.C. MAX iii. FASTENER SHALL BE EMBEDED INTO COMPETENT MATERIAL" INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. 34' 11'-4" 6'-1"3'-11" 3'-4" 1' (E) CHIMNEY PV-3.1 ROOF INFO ATTACHMENT INFORMATION Name Type Height Detail Max Landscape OC Spacing Max Landscape Overhang Max Portrait OC Spacing Max Portrait Overhang Configuration AR-03 COMP SHINGLE - UR - ULTRAFOOT 1-Story ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 6'-0"2'-4"6'-0" 2'-3" STAGGERED AR-04 COMP SHINGLE - UR - ULTRAFOOT 1-Story ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 6'-0" 2'-4" 6'-0" 2'-3" STAGGERED AR-05 COMP SHINGLE - UR - ULTRAFOOT 1-Story ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 6'-0" 2'-4" 6'-0" 2'-3" STAGGERED D5 - AR-05 - SCALE: 1/8" = 1'-0" AZIM:24° PITCH:18°11'-3" 5'-8" 7"5'-3" 7'-3" 8" 15'-1" 5'-8" 1'-6"3'-4" 3'-2" 6" D D Exp. 12/31/2026Digitally Signed On: 12/08/25 PAGE REV: D 12/5/2025 JUAN BELTRAN 2502 S ARTESIA ST, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-502BELT PR-3004162307 SHEET DESIGNER: PRAVEEN CUSTOMER RESIDENCE: TEL. (657) 272-3868 APN: 412-391-11 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE-2 MULTIPLE SOURCES OF POWER CAUTION: LABELING FORMAT LABELS SHALL BE RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS MADE OF DURABLE ADHESIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. LETTERS SHALL BE MINIMUM 3/8" IN SIZE. PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 2502 S ARTESIA ST, SANTA ANA, CA, 92704 SOLAR PANELS ON ROOF MAIN SERVICE ENTRANCE AND AGATE FEEDER BREAKER (N) INVERTER (N) ENERGY STORAGE (N) BACKUP LOAD PANEL (N) LOAD CENTER (N) A GATE AND PV+ESS BREAKER (N) REMOTE DISCONNECT SWITCH AC DISCONNECT AC DISCONNECT (N) REMOTE DISCONNECT SWITCH PV-5.1 D