HomeMy WebLinkAbout2502 S Artesia St - Plan (2)SCOPE OF WORK GENERAL NOTES
VICINITY MAPABBREVIATIONS
A AMPERE
AC ALTERNATING CURRENT
AFC ARC FAULT CIRCUIT INTERUPTER
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT
(E)EXISTING
ESS ENERGY STORAGE SYSTEM
MSP MAIN SERVICE PANEL
(N)NEW
PRE-FAB PRE-FABRICATED
PSF POUNDS PER SQUARE FOOT
PV PHOTOVOLTAIC
RSD RAPID SHUTDOWN DEVICE
TL TRANSFORMERLESS
V VOLTS
W WATTS
SHEET INDEX
PAGE
REV: D 12/5/2025
JUAN BELTRAN
2502 S ARTESIA ST, SANTA ANA,
CA, 92704
PROJECT NUMBER:
109R-502BELT PR-3004162307
SHEET
DESIGNER:
PRAVEEN
CUSTOMER RESIDENCE:
TEL. (657) 272-3868
APN: 412-391-11
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
COVER SHEETREV NAME DATE COMMENTS
B KYLE CARTER 9/15/2025 AHJ REDLINES
• ALL WORK SHALL GENERALLY CONFORM WITH 2022 CBC/CEBC, 7-16 ASCE & 2018 NDS, MUNICIPAL CODE, AND ALL
MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS.
• PHOTOVOLTAIC SYSTEM WILL COMPLY WITH CEC 2022.
• ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH CEC 2022.
• PHOTOVOLATIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM
COMPLIES WITH 690.41(A)
• MODULES CONFORM TO AND ARE LISTED UNDER UL 61730.
• INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
• RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
• SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED.
• RAPID SHUTDOWN SYSTEM IN COMPLIANCE WITH CEC 2022 690.12(B)(1) WHERE CONDUCTORS OUTSIDE OF THE
ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE
THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS
• CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D).
• ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
• 13.96 AMPS MODULE SHORT CIRCUIT CURRENT.
• 17.45 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a)(1) & 690.8 (b)].
• ENERGY STORAGE SYSTEM CONFORMS TO AND IS LISTED UNDER UL 9540.
• ENERGY STORAGE SYSTEM LIVE PARTS ARE NOT ACCESSIBLE DURING ROUTINE MAINTENANCE. SYSTEM
VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B).
• ADDITIONAL DISCONNECTING MEANS SHALL BE INSTALLED WHERE THE CIRCUITS FROM THESE TERMINALS PASS
THROUGH A WALL OR PARTITION PER 706.15(D).
• LISTED, COMBINATION TYPE AFCI SHALL BE INSTALLED WHERE BACKED UP CIRCUIT WIRING IS EXTENDED MORE
THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D).
• ALL PASS-THROUGH CONDUCTORS MUST COMPLY WITH CEC 312.8
• THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR GREATER THAN THE LOAD POSED
BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A)
• SYSTEM SIZE: 13.77KW DC, 10.0KW AC
• MODULES: (34) JA SOLAR: JAM54S31-405/MR
• INVERTERS: (1) SOLAREDGE TECHNOLOGIES:
SE10000H-USMN
• ENERGY STORAGE SYSTEM: (2) FRANKLIN: APOWER XYYY
15KWH, 10KW INVERTER OUTPUT, LITHIUM IRON
PHOSPHATE BATTERY (WEIGHT: 357LB EACH)
• MICROGRID INTERCONNECT DEVICE: (1) 280A AGATE X
CONTROL PANEL
• RACKING: ULTRAFOOT RAIL TO FRAMING SNR-DC-01507
• POWER-CONTROLLED SYSTEM (PCS) ENABLED EQUIPMENT
INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS
NEW 125A LOAD CENTER TO BE INSTALLED.
PAGE # DESCRIPTION
PV-1.0 COVER SHEET
PV-2.0 SITE PLAN
PV-3.0 LAYOUT
PV-3.1 LAYOUT
PV-3.2 MOUNTING DETAIL
PV-4.0 ELECTRICAL
PV-4.1 ELECTRICAL CONT.
PV-4.2 ELECTRICAL CALCS
PV-4.3 BACKUP LOADS
CALCS
PV-4.4 PANEL SCHEDULE
PV-5.0 SIGNAGE
PV-5.1 SIGNAGE 2
PV-1.0
DD
/ce/
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PAGE
REV: D 12/5/2025
JUAN BELTRAN
2502 S ARTESIA ST, SANTA ANA,
CA, 92704
PROJECT NUMBER:
109R-502BELT PR-3004162307
SHEET
DESIGNER:
PRAVEEN
CUSTOMER RESIDENCE:
TEL. (657) 272-3868
APN: 412-391-11
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SITE PLAN
NOTES:
·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE
SPRINKLERS.
ARRAY DETAILS:
·TOTAL ROOF SURFACE AREA: 2100 SQFT.
·TOTAL PV ARRAY AREA: 714.68 SQ FT.
·PERCENTAGE PV COVERAGE:
(TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE
AREA) * 100 = 34.03%
ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS
IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE
SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET
EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE
DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE
FIRE TESTING.
INTERIOR EQUIPMENT
SHOWN AS DASHED
FRANKLIN ENERGY
STORAGE SYSTEM (ESS)
COMMUNICATION
WIRES
GROUNDING
ELECTRODE
SE
MP
SM
PM
SP
MAIN PANEL
SERVICE ENTRANCE
SCALE: NTS
NOTE: NOT ALL ITEMS IN LEGEND
WILL APPEAR IN SITE PLAN
LC
LEGEND ELECTRIC VEHICLE
SUPPLY EQUPMENT
ACREL METER
IQ COMBINER BOX
ENERGY STORAGE
SYSTEMDC DISCONNECT(S)
AC DISCONNECT(S)
INVERTER(S)
SOLAREDGE METER
INV
DC
SUB-PANEL
AC
DEDICATED PV METER
SUNRUN METER
SEMPV LOAD CENTER
EV
AM
CB BP
BI 1BACKUP INTERFACE
FRANKLIN APBOX
BACKUP LOADS PANEL
MD MICROGRID
INTERCONNECT DEVICE
GENERATION PANELGP
BACKUP GATEWAYBG
RDS REMOTE
DISCONNECT
SWITCH
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
APB
SITE PLAN - SCALE = 1/16"=1'-0"
(E) RESIDENCE
(N) ARRAY AR-01
(N) ARRAY AR-02
(N) ARRAY AR-03
(N) ARRAY AR-04
FIRE SETBACKS
(18" TYP)
ROOF PATHWAYS
(3' TYP)
S A
R
T
E
S
I
A
S
T
(E) FENCE
(E) GATE (TYP.)
ROOF PATHWAYS
(3' TYP)
(E) CHIMNEY
ROOF PATHWAYS
(3' TYP)
ROOF PATHWAYS
(3' TYP)
(E) SHED (TYP.)
ACACLCINVAC
MP
SE
RDS MDBP
BB
AAAAAABABAA
AA
BBBBB
PV-2.0
CC
BB
CC
CC
CCC
C
C C
(N) ARRAY AR-05
ARRAY
PITCH
TRUE
AZIM
PV AREA
(SQFT)
AR-01 18° 204° 105.11
AR-02 18° 204° 84.09
AR-03 18° 294° 378.41
AR-04 18° 24° 84.09
AR-05 18°24°63.07
DD
Exp. 12/31/2026Digitally Signed On: 12/08/25
/ce/
DESIGN CRITERIA
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 0 PSF
WIND SPEED:
96 MPH 3-SEC GUST.FASTENERS:
(1) 5/16" DIA S.S. LAG SCREW: 2.5"
MIN EMBEDMENT INTO FRAMING
PAGE
REV: D 12/5/2025
JUAN BELTRAN
2502 S ARTESIA ST, SANTA ANA,
CA, 92704
PROJECT NUMBER:
109R-502BELT PR-3004162307
SHEET
DESIGNER:
PRAVEEN
CUSTOMER RESIDENCE:
TEL. (657) 272-3868
APN: 412-391-11
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
LAYOUT
4"
SOLAR MODULE
SNAPNRACK
RACKING
MODULE ELEVATION DETAIL - SCALE: NTS
D3 - AR-03 - SCALE: 1/8" = 1'-0"
AZIM:294°
PITCH:18°
D4 - AR-04 - SCALE: 1/8" = 1'-0"
AZIM:24°
PITCH:18°
•"EXISTING STRUCTURE IS ASSUMED TO BE A LIGHT-FRAME WOOD ROOF AND FREE FROM DAMAGE, DETERIORATION, OR MODIFICATION THAT WOULD COMPROMISE ITS ORIGINAL DESIGN INTEGRITY.
CONTACT ENGINEER OF RECORD IF THE FOLLOWING MINIMUM REQUIREMENTS ARE NOT SATISFIED IN COMPLIANCE WITH THE STATED RACKING DESIGN:
i: 2x WOOD FRAMING (NOMINAL)
ii: FRAMING SPACING AT 24"" O.C. MAX
iii. FASTENER SHALL BE EMBEDED INTO COMPETENT MATERIAL"
INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION.
IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12"
BOUNDARY REGION ONLY AS FOLLOWS:
••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%.
••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS.
34'
11'-4"
6'-1"3'-11"
3'-4"
1'
(E) CHIMNEY
PV-3.1
ROOF INFO ATTACHMENT INFORMATION
Name Type Height Detail Max Landscape
OC Spacing
Max Landscape
Overhang
Max Portrait
OC Spacing
Max Portrait
Overhang Configuration
AR-03 COMP SHINGLE - UR - ULTRAFOOT 1-Story ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 6'-0"2'-4"6'-0" 2'-3" STAGGERED
AR-04 COMP SHINGLE - UR - ULTRAFOOT 1-Story ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 6'-0" 2'-4" 6'-0" 2'-3" STAGGERED
AR-05 COMP SHINGLE - UR - ULTRAFOOT 1-Story ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 6'-0" 2'-4" 6'-0" 2'-3" STAGGERED
D5 - AR-05 - SCALE: 1/8" = 1'-0"
AZIM:24°
PITCH:18°11'-3"
5'-8"
7"5'-3"
7'-3"
8"
15'-1"
5'-8"
1'-6"3'-4"
3'-2"
6"
D
D
Exp. 12/31/2026Digitally Signed On: 12/08/25
PAGE
REV: D 12/5/2025
JUAN BELTRAN
2502 S ARTESIA ST, SANTA ANA,
CA, 92704
PROJECT NUMBER:
109R-502BELT PR-3004162307
SHEET
DESIGNER:
PRAVEEN
CUSTOMER RESIDENCE:
TEL. (657) 272-3868
APN: 412-391-11
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SIGNAGE-2
MULTIPLE SOURCES OF POWER
CAUTION:
LABELING FORMAT
LABELS SHALL BE RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS
MADE OF DURABLE ADHESIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR
THE ENVIRONMENT. LETTERS SHALL BE MINIMUM 3/8" IN SIZE.
PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10
2502 S ARTESIA ST, SANTA ANA, CA, 92704
SOLAR PANELS ON
ROOF
MAIN SERVICE ENTRANCE AND AGATE
FEEDER BREAKER
(N) INVERTER
(N) ENERGY
STORAGE
(N) BACKUP LOAD PANEL
(N) LOAD
CENTER
(N) A GATE AND PV+ESS BREAKER
(N) REMOTE DISCONNECT SWITCH
AC
DISCONNECT
AC
DISCONNECT
(N) REMOTE
DISCONNECT
SWITCH
PV-5.1
D