Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
10180479-20153214_2930 S. FAIRVIEW - Plan (2)
Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www. santa-ana.orq ELECTRICAL SIGN REQUIREMENTS Code references are to the 2010 California Electrical Code (CEC) A. All signs require Planning Department approval. B. All electrical signs require electric plancheck and permit. 1. Manufacturer's instructions are required at the time of submittal. C-11: 3-21-2011 2. Submit detailed installation instructions including diagrams to the Building Department for plan review at the time of submittal. Plans must include appropriate items noted by this bulletin. 3. Cash or surety bond in the amount of $200.00 is required at time of issuance for each address. The cash or surety bond will be refunded after all required finals. C. A building permit is also required - except for open or highlight neon lighting. D. Installation Requirements: CONTACT FIELD INSPECTOR PRIOR TO SIGN INSTALLATION. (SEE SECTION G OF THIS BULLETIN) 1. Conductors and equipment shall comply with California Electric Code Article 600. 2. All metal parts of a sign shall be bonded in the manner specified in Article 250. Isolated metal parts are permitted to be bonded by using an external green insulated conductor. Equipment grounding & bonding conductors must be sized by 110.26 and protected from physical damage. Minimum size is 14 AWG. CEC 600.7 3. A listed disconnect switch in the power supply primary, shall be installed within sight of sign or have permanently installed means for locking in an "OFF" position. This is also true for a transformer enclosure. CEC 600.6 4. A listed receptacle or an approved termination device shall be used for each neon electrode. To relieve stress at terminations, tubing shall be supported with listed tube supports in an approved manner within six inches of electrode connection. CEC 600.41 & 600.42 5. Every electric sign of any type shall be listed by an approved testing laboratory and shall be installed in conformance with this listing. That includes "1 of x", "2 of x" labeling for each separate unit of a· multi-unit sign. CEC 600.3 6. All "can" letters and transformers housings shall have section labels that are readily visible after installation. CEC 600.4 7. Transformers shall be located where accessible and be securely fastened in place. Page 1 of 2 , When not inside the sign, they need a 3 foot high x 3 foot wide x 3 foot deep workspace. Transformers are permitted to be located in attics or canopies provided there is a passageway at least 3 feet high x 2 feet wide with a minimum 12 inch catwalk/walkway from the point of entry. Transformers must be securely fastened and independent of T- bar when above a suspended ceiling. No part of siqn mav be fed with flexible cord when located above T-bar ceilinqs. CEC 600.21(E&F) & 400.8 8. Adequate illumination shall be provided for all working spaces about electrical equipment. This applies to attics and canopies when entry is required to service or inspect the equipment. At least one switch is required at entrance. CEC 110.34 & 600.21 9. Doorway to an attic or canopy space shall be minimum 3 feet by 2 feet wide. CEC 600.21(E) E. Open neon outline or highlight lighting. 1. To be treated as a sign by this department. However, Section D-5 & D-6 of this bulletin will not apply. 2. Neon tubing shall be located where not normally exposed to physical damage. Open neon tubing below 9 feet shall be protected from physical damage by an approved shielding method. CEC 600.30·and 110.34(E) F. Light-Emitting Diode (LED) Signs 1. Will be treated as a sign by this department. All sign rules in sections A, B, C, D, F, and G will apply as appropriate. 2. LED illumination for signage must be a listed or recognized component. Many LED manufacturers specify particular brands and models of transformers some do not. Manufacturer information to clarify this issue is required on LED sign plans. 3. Unlisted LEDs may not be used in an electrical sign or as permanently installed illumination. 110.3 4. Please have packaging or catalog cut-sheets on hand for inspector to review when LED modules do not bear listing symbols. G. Inspections 1. Contact an Electrical Inspector one (1) workday (minimum) in advance of installation to arrange a site meeting on dav of installation. 2. Call for inspection Monday through Friday, 8:00- 8:30 a.m. at (714) 647-5821. Approved prints and the job card must be on site for inspection. Page 2 of 2 137 SIGN COMPONENTS MANUAL (SAM)October 1, 2013 9. Marking - The following markings or equivalent shall be provided. Markings A and B below shall be marked anywhere where readily visible during servicing. A. "Do not attempt to repair or service a damaged sign face. For servicing of this sign, contact ."(Blank to be replaced by Applicant's Company name, City and State.) B. "Replace only with , Type ." (Blanks to be replaced by Applicant's Company name and material type or designation.) SS LIGHT CO LTD 7 SINPUNG-DONG PALDAL-GU E346996 SUWON-SI, GYEONGGI-DO 442-040 REPUBLIC OF KOREA Class 2 LED Modules, KPL, PPL, DPL, OSPL, CPL, OCPL, SPL40, SPL4, SPL(Wl), KRD, KBD, KGD, KYD, SDL, SDL(Wl), SPL, SPLE SCPL, ODL, OPL, OPL40, OPL4, OPLA KSL(Wl), KDL(Wl), CPLOA/1), KPL40/Vl), JRGB3, KR40, KB40, KG40, CSLOA/1), CSR, CSB, CSG, WSL(V\/1), WSR, WSB, WSG, WPL-(Wl), KOL-le(Wl), KOL-2C, KOL-2C(Wl), KOR-2C, KOB-2C, KOG-2C, GPL, GPL(V\/1), GRGBD, GRGB), GRGB40, JGRGB), GCS RGB, WGS RGB, WGRGB3, SSL(Wl), SCPL(Wl), SPL40(Wl), JSRGB3, SCSL, SCSL(Wl), SCS RGB, WSSL, WSSLOA/1), WSS RGB, WSPL(Wl), WSL, GDL, GPL40, GPL40(W), EPL, GCPL, OPCB 5030 6 (38, OPCB 5030 8 OP), PCB 5030 6 (1 P), PCB 5030 8 (3P), PCB 5030 6 (1 P) KP1, PCB 5030 8 (3P) KP1, PCB 5030 6 (1 P) KWL PCB 5030 8 (3P) KWL RGB 5030 8 OP), LRGB 5030 10 (313, PCB 5030 OP) R, PCB 5030 (3P) B, PCB 5030 (3P) G, PCB 4530 - le (213, PCB 4530 Wl - le (219, PCB 4530 R - le (2P), PCB 4530 8 - le (2P), PCB 4530 G - 1C (2P)m PCB 4545 - 2C (3P), PCB 4545 Wl - 2C (3P), PCB 4545 R - 2C (3P), PCB 4545 B - 2C (3P), PCB 4545 G - 2C (3P), GPCB 5030 8 OP), GPCB 5030 8 (38 W, GRGB 5030 8 (38, LGRGB 5030 10 (3P), SPCB 5030 8 (38, SPCB 5030 8 OP) W, A/L S 18, A/L S30, A/L S60, A/L PP 18, An- PP30, A/L PP60, A/L 318 (Wl), A/L S30 (Wl), A/L S60 (Wl), A/L PP18 (Wl), A/L PP30 (Wl), A/L PP60 (Wl), A/L S18(R), A/L S30(R), A/L S60(R), A/L PP18(R), A/L PP30(R), A/L PP60(R), A/L S18(B), A/L S30(B), A/L S60(B), A/L PP18(B), A/L PP30(B), A/L PP60(B), A/L 618(G), A/L S30(G), A/L S60(G), A/L PP 18(G), A/L PP30(G), A/L PP60(G), A/L RGB S18, A/L RGB S30, A/L RGB S60, A/L RGB P18, A/L RGB P30, A/L RGB P60, A/L GS18, A/L GS30, A/L GS60, A/L GPP18, A/L GPP30, A/L GPP60, A/L GS18 (Wl), All GS30 (Wl), A/L GS60 (Wl). Al GPP18 (Wl), Al GPP30 (Wl), Al GPP60 (Wl), A/L GRGB S18, A/L GRGB S30, A/L GRGB S60, A/L GRGB P18, A/L GRGB P30, A/L GRGB P60, All SS18, Al SS30, Al SS60, Al SPP18, A/L SPP30, A/L SPP60, A/L SS18 (Wl), A/L SS30 (Wl), A/L SS60 (wl), A/L SPP18 (Wl),A/L SPP30 (Wl), A/L SPP60 (Wl), WAL PP18, WAL PP30, WAL PP60, WAL PP18 (Wl),AL PP30 (Wl), WAL PP60 0/VI) WAL PP18(R), WAL PP30(R), WAL PP60(R), WAL PP18(B), WAL PP30(B), WAL PP60(B), WAL PP18(G), WAL PP30(G), WAL PP60(G), WAL RGB P18, WAL RGB P30, WAL RGB P60, WAL GPP18, WAL GPP30, WAL GPP60, WAL GPP18 (Wl ), WAL GPP30 (Wl), WAL GPP60 (Wl), WAL GRGB P18, WAL GRGB P30, WAL GRGB P60, WAL SPP18, WAL SPP30, WAL SPP60, WAL SPP18 (Wl), WAL SPP30 (Wl), WAL SPP60 (Wl) 1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less. 2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy limited circuit and is rated greater than 12V DC. 3. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. These products may be secured in place in the end product by any means available. Marking: Company name or trademark SS LIGHT and product designation. STARTEC CO LTD E350879 310-8 YUHYUN-RI YANGCHON-MYEON GIMPO-SI, GYEONGGI-DO 415-821 REPUBLIC OF KOREA Class 2 LED Module, R03-25KN. 1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less. 2. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 3. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less. 4. These products are not required to be enclosed or protected from the weather in the end product. 5. These products may be secured in place in the end product by any means available. SUNSIGNLED OPTO-ELECTRONICS CO LTD 2F BLDG B LAOBING INDUSTRY PARK ZHOUSHIRD SHIYAN TOWN BAOAN DISTRICT E359615 518108 SHENZHEN, CHINA Class 2 powered LED modules, Models IYX225U, IY)(324U, IYX220U, IYX340U, IYX326U, IYX332U, IYX341 U, MYX1 12U, MY)(120U, MYX 102U, MY)<117U, where X and Y may be replaced by any letter denoting LED color and type respectively. 1. This product is only suitable for connection to a Class 2 power source, rated 12 Volt DC or less. 2. This product has not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limits and which is rated greater than electrical ratings. 3. This Class 2 LED module is rated as noted in the electrical ratings tables. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. This product is suitable for use in dry, damp and wet locations with supply sources rated at electrical ratings or less. 5. This product is not required to be enclosed or protected from the weather in the end product. 6. This product may be secured in place in the end products by any means available. D Larnp, LED Light, LED Module I SS Light http:Uwww.sslight.net/en/product/product01.php?mode=v&:idx=739&... FRODUCT LED Module HOME > PRODUCT> LED Module > LED Module > LED Bar > LED Lighting > Exterior Light > Others ···. Korean Three LED Warm White Model Name KPL(W) Voltage DC 12V Power Consumption : 0.72W Color Temperature :Warm White % 13,5 j!®2/4,§-i,1:/TZES=?2· Size:68X16X7.5(mm) / §33 .lka:-·6'4/:0·; Featufe •--2. -//Bes*:,4- 44 1 of2 2/26/2014 1:30 PM li, LED Lamp, LED Light, LED Module I SS Light http://www.sslight.net/en/product/product01.php?mode=vkidx==739&... *MCi;DAROUSRWN'·48'·42**2 :1:·ap.,I.91,i:- : · LED Use SMD TYPE A Grade Chip with Excellent Life span and Brightness. · Brightness Continuance Designed ic minitnize dainage of Chip bom static electikity, Provides con=tant Voli ose br same bright.e. S at 0(I time, - Angle of Beam (Prevent Bla¢kenrng} · Waterproof Minimum 120 degrk Anste of beant spri:i.:i of lEO is possible to displir, witllout 810*kenins with Minirnum Quantiri. Epoxy Adherence on LED module ID prnvent moistum. IP 65 ·Cert;Med. · Radiation of Heat · Safety · One Rank Remove over 90% of heat Ily :adiantheal dcuit and mainiants consbtent brightne/5. Safe with Low Voltage of DC 12V. Use One Rank Chip ?01-Seme color of each module. 0,6....e.dien.3+6.96*-».9¥02 -i:Specification .· .- . ---.·> :·....., ..i. . .. .. = ·4 1 KPL(W) LED Korean ;Chip LED Color Warm White Connection Wire 10 Wire / Lenglh 90mm Sue 68'16-7.5mm Voltage DC 12V / Non Polar Angle 120* Cunent Consumptioh 60mA Water Ploof IP68 (Waterproot Certified) Power Consumption 0.72W Radiation of Heal Radiation ot Heal Circuit Series Connection Max, 50 modules Brighjness 4,000mcd 1 pcs =r:>.*»29**5*:--40#5:03 ·43'43;!Flkff:/81.3,1://44:i·14.Z :iii.z:- I Unil: mm 68 90 UL{ Om®.-R Onfe·-e[J sA=r O }=10 SA=r [3 33 7.5 44*·*:jn·***ARMS*Pb 3 .*.Best for the middle / big size of channel Cover 500,nm square) . Attach each 50Inrn-10Omm per module when channel hight is standard 80rn,11-120mm *. Excellent for duplex sheet attached signageor high brightness SS LIGHT S:·lin liB'ice::051···44. 5;1 1325*·.1 D;:iMi '1(-* Scovt 1 56-927. 9*01;t nt KweaSS UGHT CO:. UD Rm.L':AE, Fario:t, 7, 9,-9.t,is-,»6.-Skit; :·. buv.,09-·9'*4,1*·-do :142--040, R.,1.:Bli·: 61 Keed E ® C.Ius F© C€%9®*WBO ABOUT SS UGHT I PRODUCT I LED Module I LED Bar I LED lamp I Exterior Light I Peripheral Devkes(Others) 1 SUPPORT I NEWS & NOTICE I SITEMAP 2 of2 2/26/2014 1:30 PM December 13, 2013 Mr. Xavier Patin Chief Financial Officer Tailgate Printing, Inc. 2930 S. Fairview Street Santa Ana, CA 92704 Subject: Lease dated September 23, 2010, between Tailgate Plinting, Inc., as "Tenant", and APG OCIC LLC, successor-in-interest to Lapco Industrial Parks as "Landlord", for the Premises located at 2930 S. Fairview Street, Santa Ana, CA CONSENT TO ALTERATIONS Dear Xavier: In accordance with Tenant's request the Lessor under the above-referenced Lease hereby consents to Tenant's installation of those certain Alterations to the above-referenced Premises as described in the plans and specifications attached to this letter consisting of plans prepared by Hernandez Signs dated 11/22/; provided, however, that the foregoing consent is expressly subject to and conditioned upon the following: 1. The Alterations shall be constructed pursuant to the plans and 1!hire specifications attached to this letter as they relate to the structural and mechanical portions of the work.Real Estate Group 2. All improvements shall be constructed by a licensed, bonded and insured contractor. Contractor's name and California Contractor's License number shall be furnished to Unire Real Estate Group, Inc. prior to commencement of work. 3. The installation of the Alterations shall be conducted in compliance with all Applicable Laws (as the term is defined in the above- referenced Lease), including without limitation the provisions of the Americans with Disabilities Act ("ADA"), and in a good and workmanlike manner. 4. All costs in connection with Tenanfs installation of the Alterations consented to hereunder shall be fully paid by Tenant, and Tenant shall 1800 E. Imperial Hwy.not permit any mechanic's, materialmen or other liens to be filed Suite 205 against the Premises or any interest therein as a result of such work. Brea, CA 92821 P 714.990.2100 F 714.990.2120 www.uniregroup.com 5. A completion and indemnity bond is not required. (If required, such bond must be submitted to and approved in writing by Lessor prior to Lessee's commencement of the installation of the Alterations.) 6. The installation of the Alterations shall otherwise conform with all conditions and requirements of Article 12 of the above-referenced Lease and all other terms, provisions, and requirements of said Lease. 7. Tenant shall provide to Lessor prior to the start of construction, but in no event later than fifteen (15) days following the date of this letter, a Certificate of Insurance and Endorsements per the attached requirements. 8. Tenant shall provide to Lesser, prior to the start of construction, a list of subcontractors and construction schedule. 9. Upon the completion of the Alterations, Tenant will promptly provide to the undersigned, on behalf of the Lessor: (a) a copy of the City- approved plans and specifications for the Alterations, (b) a copy of the City building permit for the Alterations, and (c) a copy of the signed-off City inspection card for the Alterations. 10. Upon Lessor's request, the Alterations will be removed and the area restored to original condition at Tenant's cost, at the termination of the Lease. This consent has been given with the understanding that (i) Tenant will comply with each and all of the conditions set forth in this letter, (ii) no Event of Default currently exists under the above referenced Lea se, and (iii) no Hazardous Materials (as that term is defined in said Lease), including but not limited to asbestos or asbestos-containing materials, shall be used by Tenanes agents or contractors in the construction of any of the Alterations permitted hereunder. Please note that it is the Lessor's intention to post and record a Notice of Non- Responsibility or other notice Lessor deems proper in connection with Subtenant's construction and installation of the Alterations consented to hereunder. If you have any questions, please contact nie at (714) 990-2100 or at narbutas@uniregroup.com. Sincerely, Unire Real Estate Group, Inc. As Agent for APG OCIC LLC (f-2-*) Audra N. Narbutas Portfolio Manager Encl: Insurance Requirements Approved Plan night effect look PRINTING INC. > 9' sample --...,'." 1. 45 sq. ft.PROPOSED WALL SIGN 1 Channel Letters 1 Internally Illuminated Individual Reverse Channel letters with Halo LED illumination. I81LQ8IE - FACE f nish; RUSTIC (non-illuminated) HALO LED illumination : RED led illuminated PRINTING INC Plastic formed individual letters non-illuminated . Color: Black - 70' [ 1 2930 101 landlord's approval City approval 26' MBANANDEZ- eNS.£ .'.4.- .J I....i-... r. I'.% 1„5.1,1.0-/ I- m F= ./.= +|lob Address : 2930 5. Fairvlew St. Santa Ana, Ca 92704 'AI Im;J Customer: Tailgate P,Inting Inc.NOTTO SCALE 72 w REVERSE LIT CHANNEL LETTERS site plan 3.5" Aluminum Return - Clear Lexan Back .090" Aluminum race Sealtite Connector Clip Attachment · LED Iliumfnaihn 121 . 1 t Sign , _ : i-..'J here IT VIEW LED Lead Wire (1A1,4,-, Clip attachment PVC Standoff Seattlte Connector LED Illumination .090" Aluminum Face c Power Supply - Clear Lexan Back SIDE VIEW HERNANDEZ';IGNS.£OW& Front Bevation Sign Job Address: 2930 5. Fairview St. Santa Ana, Ca 92704 2+ lim/13 Cle'Iive $,0.,Int -2,* 1 5300 Pad#Imvd.*Untingtof,Park, C,90255 Customer: Tailgate Printing Inc.NOTTO SCALE TAGE 20#2 3233852181 Contar: Jackie 48" 0 1 0 L -A 21 1 0 <A halo/ / /77 /7 L 8•night effect sample 40.uvUOUV/CUL 9, PROPOSED WALL SIGN 45 sq. ft. Channel Letters 1 Internally Illuminated Individual linked Reverse Channel letters with Halo LED illumination. TAILGATE FACE finish : RUSTIC (non-illuminated) HALO LED illumination : RED PRINTING INC.OA' Plastic formed lodividual letters non-illuminated, Color: Black. NTING INC. > j 1 10 70' 1C APPROVED . PLAMNNC Di¥?8igN P,EASTERi-izktlt=ULLk:Ej G.P.-_1 612 _zone M 1 DATE LANNI:04]Gli'iiimi::1'"I"Illlllllllll- r 6 \45ji HERNANDEZhIGNS..Clt''lit :10...t - 32/fOS.7161 colton leekll 5300 P.¢IR,Blvd. Huiti„Utun Parl„ Co 90255 VE . , D16: FniEI,vationSIgn Customer : Tailgate Printing Inc. RETAIN DL/ME FOR AJTURE REVISIONS.>LALECT Tn jiCliLCi:irllEd*hill CON[*TIONS 1 O iN-AER:OR Tr ONLY Cl NO EXTER'OR N TE,RATIONS/MODIFICATIONS; O ALL MATERIALS TO MATCH EXISTING O SCREENING REQUIRED Job Addresq]29*jff#jfyfetsNOR€A,i2Rf#2*4%1£ lim/13 NOTTO SCALE PAGE: ' of 1 749!TICKS: D Oh. REVERSE LIT CHANNEL LETTERS 3.5" Aluminum Return t £ , Clear Lexan Back .090" Aluminum Face site plan Sealtite Connector -'77-Z· 1 L.-1 C 47 " - 2 1 1 :, , Clip ttachmc@ / 14--•«4.--t-*-,-. · i.,-A.-;L.*_AL. 15 LED Illumination j FRONT VIEW 1 *Ji< 'll .. -rs>1711-tirrifrf=.-90-n .20' - Sign LED Lead Wire ("Whip") Clip attachment .1 PVC Standoff --1 Sealtlte Connector t,_.__ jioon "'7=:592£,9, ' -tcy--0 LED Illumination h, --:ti '112rri.Ob.-2 .090" Aluminum Face . Power Supply -1 1 · L_-1 Clear Lexan Back . 1 1!2Etrf.N'.4, SIDE VIEW HERNANDEZSIGNS,wa CREATIvt SIGNAGE 5300 Pacific Blvd. Huntington Park. Ca 90255 323.585.2161 Contac: Jackie DW6: Front Elevation Sign Job Address : 2930 S. Fairview St. Santa Ana, Ca 92704 DATE: 11/22/13 Customer: Tailgate Printing Inc.NOTTO SCALE PAGE: 2 of 2 M ;· e--5-:=- here 1 UJ€G h City of Santa Ana. CBC & CEC 2013 Minimum (4) screws per letter, maximum 24" on center, 2" , penetration, #10 sheet metal screws, & (2) 1/4" drain holes per letterent sign(s) Isnnect for the monumrequired or the dedicated CCuit breaker(s). mustos*jon.eoffg n A \oc, disco lockableany power supply in attic or abovemmediately from a ladder or-Inor & passage with a,''Access luwith a 2 x 3 foot access uu\\06lay.12.Inch maof Santa Ana Planning city 'Iding Agency6 80, - . ELECTRICAL 1 PLAN APPROVAL This set of plans and spectilcanons must be Impt onthe job at all times and It is unlawful to make anychanges or alterattons on same without wiltten per-' mission from the Department of Building Safety City of Santa Ana. The approval of this plan and specifications SHALLNOT,held to permit nor be an approval of theviolattorror any provisions of ANY City Ordinalpe or State Law.J rerec %-\243 . 210} CITY OF SANTAANA DEPARTMENT OF BUILDING SAFETY N-i APP PERMIT TYPE:t23'4*g MECI GRAD PERMIT#|0 18')1_13 / _ OCC. GROUP (53-))95%2 CONSTR. TYPF. CODE EDITION 20\-5 FLOOD ZONE FLOOD ZONE GERTIE REQ'D YE/ M- I ROfFLM YES RADIANT BAMMIER @ ROOF YES RESIDENTIAL [>EV. FEE YES < SCHOOL DISTRICT YES Z 0 ,98-id< -9.1-EMAP.RASTRODM DITAL I CITY OF Ullillil 1- -r . 7 Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M=19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org DISABLED ACCESSIBLE 1- tr-SINGLE-ACCOMODATION 1 v SANITARY FACILITIES 1 . -111.- i f ACC-06 CBC 2010 i .,3 -t%7· '50{4" C •G" 6446 BAP- 4 h/4 0 lair Storage Rootry -14* Muct . - ••AbL #,gle•01{,9 - U' MY#4 4 Toilet Facilities 11158.3.2 and 11158.4 Single-accommodation toilet facilities.There shall be sufficient space in the toilet room for awheelchair measuring 30 inches wide by 48 incheslong to enter the room and permit the door to close.There shall be in the room a clear floor space of at least60 inches in diameter, or a T-shaped space complyingwith Figure 11812(a) and (b). No door shall encroachinto this space for more than 12 inches except for thepanel door to any water closet compartment if there isone. (See Figure 118-14 Thewaterclosetshali belocated in a space which provides a minimum 28-inchwide clear space from a fixture or a minimum 32-inchwide clear space from a wail at one side. The otherside shall provide 18 inches from the centerline of thewater closet to the wall. A minimum 48 inches by 60inches of clear space shall be provided jn front of thewater closet. All doors, fixtures and controls shall be on an accessible route. The minimum clear width of an accessible route shall be 36 inches except at doors(see Section 11338.2). Ifaperson in awheelchairmust make a tum around an obstruction, the minimumclear width of the accessible route shall be as shown in Figure 11 B-58. (See also Figurn 11 8-1 A). Doors shallnot swing into the clear tloor space required for any fixture. - 4 *12 1-1/4" -TC) L *. See Section 11158.7.21-1/2' 1*1.- 7/ 250 pound point load DIAMETER N.£-111 &%01 for structural strength :<25 ./ 9,0.... 4 *12 4 00 +.0. 4 el t.' / TOIL.STO \C y 011" -43" 600¢*K. 60" MIN DIAMETER CLEAR .·1 22 :1483 9 a 11r# PLA, 1.J<1 23' r u 317 »'•-¥44+* 94> ' 't,- NONE. -..Wt 9. .... 3: Hiwify<Ext k .0 >2 .),vijcnifprl 4 ..rb1.2 1 6 10,1.4 .4-wi fit 4%12 f 4 * 'Al 56 4.... -4 h ''bl ..... p;,A;:2 Vf.;*; :. 4,*,·4*,;2.;iti2>3. 15r.r' c'Mphi' 1. 1.W 90*.=*i-Tr..£ € Al f %l 6<2#'.221'.ZEZU'..:..,.'. 12Z-4 1203 Ventilation.Toilet rooms shall be provided with a fully openableexterior window with an area not less than 4 percent offloor area being ventilated or be mechanically ventilatedin accordance with the 2010 California Mechanical Code Chapter 4. CENTERLINE OF FIXTURE CENTERUNE 1 OF FIXFURE -j 12'*- 3€ MIN. LONG -L._ 18,1 GRAB BAR 1 1 12* - -w: ro r-h MIN.1.--IL_J 1 CL¥I- k----.- FLUSH - , ACT}VATOR ON WIDE SIDE i CLEAR Single Occupancy Toilet FIGURE 11B-lA 111 t f 11124" \C ' MIN. .EAR 04 ZO 21 ULL r 1% WAU---- Section Through Grab Bar FIGU RE 11 BA C ?93/10?0jiFEATORS 1 1115BA.1 hm3and 1115B.7 Diameter orwidth and structural strength.The diameter orwidth of the gripping surfaces of a grab bar shall be 11/4" inches to 112 inches or the shape ,/ 4le r ---1-UNkshall provide an equivalent gripping surface. If grab 49 2 . 410-- , bars are mounted adjacent to a wall, the spacebetween the wall and the grab bars shall be 1 1/2 €7\ inches. See Figure 11 8-1(1 Awmot<' 6 --57,f Sales Fioor i J €66 »1 0-4 Grab bars shall not rotate within their fittings and structuralstrength shall be per Section11158.7.2 of the 20'10 CBC.*64 /tdue., 14=or y, fl 14 V 9.4,7- //1115B.4 Grab Bars. U 11158.4.1 Item 3 Location. ' 9 Grab bars located on each side, or one side and theback of the accessible toilet stall or compartment, shallbe securely attached 33 inches above and parallel to the floor, except that where a tank-type toilet is used i *4' ID' which obstructs placement at 33 inches, the grab barmay be as high as 36 inches. Grab bars shall be at 4/ 1 least 42 inches along with the front end positioned 24 4 inches in front of the water closet stool. Grab bars atthebacksha#notbe/essthan36*ches/ong See 66 < Figures 118-1A and 118-IC. E 3 3 I44.99 h.,7- : / 4 FWse.ut» r 1 -2 '. rev: 8/7/12 21,2 ./ 12 f#-01 0 f R f-'#'-9. fe A - 91 1 )69 ) I /\ 1,Front Door - 44" k 93 0 t--11Zi-4 - ,,2¢ ., ·84*4 2 -1 i 111,# ' Page 1 of 2 t 1(:J /.,1:¢92. i y e b i '4 1 -1.- Non load bearing partition wall is constructed to California Building Code Store Name:Standards with quality 20,<4* studs, spaced 16* off center, with full GLM Vaporium sole plate and double top plate fastened with nail and 2 W nall pin with member to roof joist 14 W spacing. 44*all thread anchor to cgncrete with 3"xy square washers. Lateral top NO ELECTRICAL WORK PRESENT Store Address: •NO PLUMBING WORK PRESENT Rr 3801 S. Harbor Blvd. # E •Partition is finished with standard drywall and mud. Santa Ana, CA 92704 • 1,200 sq. fv30 = occ.49 max 33*·Drawn by Donn Nguyen - 51 141, x44· wl He' 17'CJ4/M ct.Or 111*/ 1 /'* 3,/ 9;M&% A ,=-1/voihe#s . .---- -4 E \M- b E-\23 1 7% 4 L M