Loading...
HomeMy WebLinkAbout1920 E 16th St & 1920 E 17th St Unit #200-REV 1 - PlanREF REF 1'-6"1'-6" T T UP UP UP UP 11'-4" 10' MIN. FIRE SEPARATION DISTANCE 10 ' - 1 0 " 10 ' - 1 0 " ACCESSIBLE ROUTE AC C E S S I B L E R O U T E ACCESSIBLE ROUTE AC C E S S I B L E R O U T E 3' - 0 " OP E N I N G A3 A3 PLEASE SEE SHEET A2.3 2ND FLOOR EGRESS PLAN FOR OCCUPANCY 1 DN DN 21" HEIGHT RAMP 8.33% PC7 PC7 PC7 PC7 PC7 PC8 PC8 21'-0" 5'-0" DN UP 21'-0" ACCESSIBLE ROUTE AC C E S S I B L E R O U T E ACCESSIBLE ROUTE AC C E S S I B L E R O U T E AC C E S S I B L E R O U T E ACCESSIBLE ROUTE 5'-4" LA N D I N G LANDING 5' - 0 " LA N D I N G LANDING 5' - 0 " 5' - 0 " A0.0 CO V E R S H E E T SHEET# JOB# DRAWN DATE SCALE RE V I S I O N S DEC. 2025 YC24005 be r e p r o d u c e d w i t h o u t t h e w r i t t e n c o n s e n t o f Y N G A R C H I T E C T S , I N C . Th i s D o c u m e n t i s t h e p r o p e r t y o f Y N G A R C H I T E C T S , I N C . a n d s h a l l n o t CO P Y R I G H T C BL E S S E D I N T E R N A T I O N A L C H U R C H C H A N G E O F U S E 19 2 0 E 1 7 T H S T R E E T , S U I T E 2 0 0 19 2 0 E 1 6 T H S T R E E T SA N T A A N A , C A 9 2 7 0 5 T.I. PC 4 0 8 / 2 3 / 2 4 4 T H S U B M I T T A L PC 5 10 / 0 2 / 2 4 5T H S U B M I T T A L AR C H I T E C T S 15 2 4 B r o o k h o l l o w D r i v e , S u i t e 6 Sa n t a A n a , C A . 9 2 7 0 5 71 4 - 4 2 6 - 2 9 2 0 T . ww w . y n g a r c h i t e c t s . c o m R U.S. GREEN BU I LDING COUNC IL MEM B ER .\ S i g n a t u r e Y e n n y N g . j p g No . C - 3 2 7 9 8 HC F R A D SE N E S TAT L CA I OF E ILC A ORNITC ITE YE N N Y N G DA T E RE N E W A L 03 - 3 1 - 2 5 PC 6 06 / 1 6 / 2 5 OC F A S U B M I T T A L PC 7 1 0 / 2 9 / 2 5 7 T H S U B M I T T A L PC 8 1 2 / 2 / 2 5 8 T H S U B M I T T A L PC 9 12 / 1 9/2 5 9T H S U B M I T T A L SCALE: N.T.S. BLESSED INTERNATIONAL CHURCH CHANGE OF USE ARCHITECTURAL A0.0 COVER SHEET GR.1 CALIFORNIA GREEN CODE GR.2 CALIFORNIA GREEN CODE GR.3 CALIFORNIA GREEN CODE A0.1 ACCESSIBILITY NOTES X1.0 DEMO SITE PLAN X2.0 EXISTING FIRST FLOOR PLAN X2.1 DEMO SECOND FLOOR PLAN X4.1 EXISTING ELEVATIONS A1.0 PROPOSED SITE PLAN A1.1 ENLARGED SITE PLAN A1.2 SITE DETAILS A2.1 PROPOSED 2ND FLOOR PLAN A2.2 PROPOSED 2ND RCP A2.3 2ND FLOOR EGRESS PLAN A2.4 ENLARGED RESTROOM AD1 ARCHITECTURAL DETAILS AD2 ARCHITECTURAL DETAILS AD3 ARCHITECTURAL DETAILS AD4 ARCHITECTURAL DETAILS MECHANICAL M000 MECHANICAL NOTES M001 MECHANICAL SCHEDULES M100 MECHANICAL PLAN M101 MECHANICAL PLAN - ROOF PLAN TM00 MECHANICAL TITLE 24 - 1 ELECTRICAL E000 ELECTRICAL SPECIFICATION E001 SINGLE LINE DIAGRAM/ SCHEDULES E100 LIGHTING PLAN - AREA A E101 LIGHTING PLAN - AREA B E102 PHOTOMETRIC PLAN - AREA A E103 PHOTOMETRIC PLAN - AREA B E200 POWER PLAN - AREA A E201 POWER PLAN - AREA B E202 POWER PLAN - ROOF TE00 TITLE 24 - INDOOR PLUMBING P000 PLUMBING NOTES & SCHEDULES P001 PLUMBING DETAILS & SPECIFICATION SHEETS P100 WASTE & VENT PLAN P200 WATER PLAN TP00 TITLE 24 1920 E 17TH STREET, UNIT 200, SANTA ANA, CA 92705 1920 E 16TH STREET, SANTA ANA, CA 92705 OL D T U S T I N A V E . CA B R I L L O P A R K D R . 16TH ST. E. WELLINGTON AVE. 17TH ST. SITE 55 F W Y N W I L L I A M S S T . 15TH ST. N T U S T I N A V E . MA B U R Y S T . INDEX OF DRAWINGS 1. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITIONS OF ALL APPLICABLE BUILDING CODES, THE AMERICANS WITH DISABILITIES ACT, AS WELL AS ALL OTHER LOCAL GOVERNING CODES AND ORDINANCES. 2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, WHETHER SHOWN HEREIN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE FOR THE REPAIR OR REPLACEMENT OF UTILITIES AND/OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK. 3. CONTRACTOR SHALL MAINTAIN THE SITE IN A CLEAN AND ORDERLY MANNER. ALL DEBRIS SHALL BE REMOVED FROM PREMISES, AND ALL AREAS SHALL BE LEFT IN A BROOM-CLEAN CONDITION AT ALL TIMES. THE CONTRACTOR SHALL LOCATE AND MAINTAIN A TRASH BIN AT THE SITE. SUCH BIN SHALL BE OF ADEQUATE DIMENSION TO KEEP THE SITE CLEAN AT ALL TIMES. THE BIN SHALL BE REMOVED AND EMPTIED AS REQUIRED. DUST RESULTING FROM SALVAGE, DEMOLITION AND REMOVAL WORK SHALL BE CONTROLLED TO PREVENT THE IMPOSITION OF A NUISANCE OR HAZARDOUS CONDITION TO THE ADJOINING PORTION OF THE PROJECT. THE USE OF WATER WILL NOT BE PERMITTED WHEN SUCH USE WOULD RESULT IN HAZARDOUS, OR OTHERWISE OBJECTIONABLE CONDITIONS. 4. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. FIRE EXTINGUISHERS (OTHER THAN THOSE TO BE INSTALLED UNDER THE GENERAL CONTRACT) SHALL BE PROVIDED ON SITE AT ALL TIMES. CONTRACTOR SHALL PROVIDE ALL REQUIRED PROTECTION. INCLUDING, BUT NOT LIMITED TO, SHORING, BRACING, AND ALL SUPPORTS NECESSARY TO MAINTAIN OVERALL STRUCTURAL INTEGRITY OF THE BUILDING. ALL DEMOLITION AND CUTTING SHALL BE PERFORMED IN A MANNER AND BY METHODS WHICH ENSURE AGAINST DAMAGE TO EXISTING WORK. 5. NO STRUCTURAL MEMBERS SHALL BE CUT TO ACCEPT PIPES, VENTS, DUCTS, ETC., EXCEPT AS DETAILED OR SPECIFIED HEREIN. 6. ALL ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL CONFORM TO THE REQUIREMENTS OF LEGALLY CONSTITUTED AUTHORITIES HAVING JURISDICTION. 7. ALL GLASS AND GLAZING SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES AS WELL AS THE U.S. CONSUMER PRODUCT SAFETY COMMISSION, SAFETY STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS (47 FR, 13516 TITLE #16, CHAPTER 11, PART 1201). 8. PROVIDE ATTIC DRAFT STOPS AND VENTILATION IN CONFORMANCE WITH ALL APPLICABLE BUILDING CODES. 9. EXTERIOR OPENINGS SHALL COMPLY WITH ALL SECURITY REQUIREMENTS AS OUTLINED IN ALL LOCAL BUILDING CODES AND/OR ORDINANCES. 10. CONTRACTOR SHALL ASSIST OWNER IN OBTAINING "CERTIFICATE OF OCCUPANCY" OR "OCCUPANCY PERMIT" AS NECESSARY. 11. GENERAL CONTRACTOR SHALL SEAL ALL GAPS, HOLES, AND CRACKS IN THE BUILDING CONSTRUCTION AS REQUIRED TO CONTROL INFILTRATION OF INSECTS AND RODENTS. 1 A-1 1 A-1 1 A-1 1 1 A P-1 1 101 1 RESTROOM ACCESSORY NUMBER REVISION NUMBER SEE COLOR FINISH NOTES OR SCHEDULE SHEET REFERENCE NOTE NUMBER ROOM NUMBER WINDOW NUMBER DOOR NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER ELEVATION NUMBER SHEET NUMBER DETAIL REFERENCE DETAIL REFERENCE ELEVATION REFERENCE SECTION REFERENCE DOOR REFERENCE WINDOW REFERENCE ROOM REFERENCE NOTE REFERENCE COLOR / FINISH REFERENCE REVISION REFERENCE RESTROOM ACCESSORY REFERENCE OWNER: BLESSED INTERNATIONAL FELLOWSHIP, INC. PASTOR RYAN LEE 1920 E 17TH ST. SANTA ANA, CA 92705 (714) 747-8999 ARCHITECT: YENNY NG YNG ARCHITECTS, INC. 2530 RED HILL AVE, SUITE 215, SANTA ANA, CA 92705 TEL : (714) 426-2955 TOAN@YNGARCHITECTS.COM CIVIL: P.A. ARCA ENGINEERING INC. 500 EAR CARSON PLAZA DRIVE, SUITE 201, CARSON, CA 90746 TEL: (310) 768-3828 PERT@PAARCAENGINEERING.COM STRUCTURAL: LEE & LEE STRUCTURAL ENGINEERING INC. 3550 WILSHIRE BLVD., SUITE 480 LOS ANGELES, CA 90010 TEL: (213) 351-0034 SYLEE@LEENLEE.NET M.E.P.: CDI ENG DAVID KANG 16520 BAKE PKWY, #100, IRVINE, CA 92618 TEL: (949) 336-6636 DKANG@CDIENG.COM SCOPE OF WORK 1. 1920 E 16TH ST: PROPOSING SITE IMPROVEMENTS INCLUDING DEMOLITION OF THE SITE WORK AND REMOVAL OF THE PLUMBING FIXTURE, NEW LANDSCAPE PLANTERS IN THE PARKING LOT, NEW TRASH ENCLOSURE, AND NEW ACCESSIBLE PATH OF TRAVEL. AND NEW ACCESSIBLE PARKING SPACES, RE-STRIPPING, INSTALLATION OF ONE NEW LIGHT STANDARD, AND BOLLARD. 2. 1920 E 17TH ST #200: PROPOSING TENANT IMPROVEMENTS TO CONVERT 10,390 SQ. FT. OF EXISTING OFFICE INTO A CHURCH. THE NEW FLOOR PLAN CONSISTS OF 7 OFFICES, 7 STORAGE ROOMS, A MEETING ROOM, A BREAK ROOM, A KITCHEN, RESTROOMS, 180 FIXED SEATS, A STAGE, AND A CRYING ROOM PROJECT DATA ADDRESS: APN: LEGAL DESCRIPTION: ZONING: OCCUPANCY: CONSTRUCTION TYPE: LOT SIZE: TENANT IMPRO. AREA STORY: BUILDING HEIGHT: ALLOWABLE BUILDING HEIGHT: PARKING LOT: 1920 E 17TH STREET, UNIT 200, SANTA ANA, CA 92705 - PC#104122327 1920 E 16TH STREET, SANTA ANA, CA 92705 PC# 104122326 400-011-03 N-TRACT: 6313 BLOCK: LOT: 3 C5 - ARTERIAL COMMERCIAL A3 - ASSEMBLY B - BUSINESS S1 - STORAGE V-A (FIRE SPRINKLER SYSTEM IS NFPA13) METAL STUD INTERIOR PARTITION - NON-FIRE-RATED AND NON-BEARING PARTITIONS 34,021 SF. 10,390 SF. 02 32'-0" (EXISTING) 70 F. (TABLE 504.3) 400-013-07 400-013-06 CURRENT CODES ALL CONSTRUCTION SHALL COMPLY WITH: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE SANTA ANA MUNICIPAL CODES PARKING CALCULATION TOTAL PROVIDED PARKINGS: ON-SITE PARKING:148 PARKINGS OFF-SITE PARKING LESSOR 28 PARKINGS TOTAL 176 PARKINGS STANDARD ACCESSIBLE PARKING PROVIDED 05 PARKING VAN ACCESSIBLE PARKING PROVIDED 01 PARKING SEC. 41-1342: OFFICES, BUSINESS AND PROFESSIONAL. THE MINIMUM OFF-STREET PARKING REQUIREMENTS FOR BUSINESS AND PROFESSIONAL OFFICES, INCLUDING PSYCHOLOGIST ARE AS FOLLOW: THREE (3) SPACES FOR EACH ONE THOUSAND (1,000) SQUARE FEET OF GROSS FLOOR AREA. SEC. 41-1346: MEDICAL, DENTAL, PSYCHIATRIC AND CHIROPRACTIC OFFICES AND CLINICS. THE MINIMUM OFF-STREET PARKING REQUIREMENTS FOR MEDICAL, DENTAL, PSYCHIATRIC AND CHIROPRACTIC OFFICES AND CLINICS ARE AS FOLLOW: FIVE (5) SPACES FOR EACH ONE THOUSAND (1,000) SQUARE FEET OF GROSS FLOOR AREA. SEC. 41-1411: CHURCHES, CHAPELS AND RELIGIOUS MEETING HALLS a. THE MINIMUM OFF-STREET PARKING REQUIREMENTS FOR CHURCHES, CHAPELS AND RELIGIOUS MEETING HALLS ARE AS FOLLOWS: ONE (1) SPACE FOR EACH THREE (3) FIXED SEATS, PLUS ONE (1) SPACE FOR EACH FIFTY (50) SQUARE FEET OF FLOOR AREA IN SEATING AREAS WITHOUT FIXED SEATS. b. FOR PURPOSES OF THIS SECTION, "SEATING AREAS" SHALL INCLUDE CONGREGATION SEATING, PRAYER AND CRY ROOMS, PASTOR AND CHOIR AREAS, AND SIMILAR AREAS. VICINITY MAPPROJECT TEAMSYMBOL LEGENDS NOTE: THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM BY-PRODUCTS, SOIL PARTICULATE CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. GENERAL NOTES FOR REFERENCE ONLY LAND USE SIZE (SF.) PARKING REQ. PER ARTICLE XV OF CHAPTER 41 OF THE SAMC TOTAL PARKING SPACES REQUIRED DENTAL OFFICE 6,080 5 PER 1000 30 OFFICE 11,342 3 PER 1000 34 CHURCH OFFICE 1,677 INCLUDES OFFICES 1-7 AND MEETING ROOM 5 CHURCH (184 SEATS)N/A 1 PER EVERY 3 SEATS 62 FUTURE OFFICE 2ND FLOOR 6,342 3 PER 1000 19 NON-PROFIT OFFICE 1,287 3 PER 1000 4 TOTAL 154 ENTIRE SECOND FLOOR W=23.9 F=351, P=798 I={351/798-0.25}x23.9/30=0.15 TENANT IMPROVEMENT W= 21.6 F= 207, P=431, W=21.6 I= {207/431- 0.25}x21.6/30=0.16 OCCUPANCY B (FUTURE TENANT NOT IN SCOPE) ALLOWABLE AREA: 54000 SF > ACTUAL AREA 8382 SF 8382/54000=0.2 NOTE: THE TOTAL SECOND-FLOOR AREA OF 19,812 SQ FT IS LESS THAN THE ALLOWABLE AREA OF 34,500 SQ FT; THEREFORE, THE ALLOWABLE AREA COMPLIES. ALLOWABLE AREA CALCUL. TYPE VA - SM A3= 34500 SF / 3 STORIES / 70 FEET B= 54000 SF / 4 STORIES / 70 FEET S1=42000 SF / 4 STORIES / 70 FEET B=54000 SF / 4 STORIES /70 FEET (FUTURE TENANT NOT IN SCOPE) TOTAL BUILDING AREA / MORE RESTRICTIVE 10390/34500=0.3 FOR TENANT IMPROVEMENT AREA 19812/34500=0.6 FOR ENTIRE SECOND FLOOR REF NO T I N S C O P E EX I S T I N G O F F I C E F O R N O N P R O F I T OR G A N I Z A T I O N O N F I R S T F L O O R NO A S S E M B L Y U S E 249 SF GREEN ROOM 121 SF ELECTRICAL 533 SF STAGE 313 SF KITCHEN 25 SF STORAGE MEN WOMEN 40 SF STORAGE 48 x 48 60 x 60 48 x 4860 x 60 48 x 4 8 60 x 6 0 60 x 6048 x 48 3 RISERS @ 7" MAX 2 RISERS @ 7" MAX 3,250 SF SANCTUARY ALL GENDER 1 ALL GENDER 2 121 SF PANTRY 278 SF MEETING435 SF BREAK ROOM 175 SF OFFICE 7 239 SF STORAGE 3 136 SF STORAGE 4 205 SF OFFICE 1 71 SF STREAMING TECH.100 SF AV BOOTH 71 SF TRANSLATOR 205 SF OFFICE 3 205 SF OFFICE 4 317 SF CRY ROOM 562 SF STORAGE 2 133 SF STORAGE 1 205 SF OFFICE 2 225 SF OFFICE 6 179 SF OFFICE 5 36 SF STOR. 5 REF UNUSED PLACE B OCCUPANCY NO ASSEMBLY USE 36" 33"33"33"33" 1'-6"1'-6" T T UP UP UP UP 11'-4" 10' MIN. FIRE SEPARATION DISTANCE 10 ' - 1 0 " 10 ' - 1 0 " ACCESSIBLE ROUTE AC C E S S I B L E R O U T E ACCESSIBLE ROUTE AC C E S S I B L E R O U T E 3' - 0 " OP E N I N G NOT IN SCOPE A3 A3 PLEASE SEE SHEET A2.3 2ND FLOOR EGRESS PLAN FOR OCCUPANCY 1 DN DN 21" HEIGHT RAMP 8.33% PC7 PC7 PC7 PC7 PC7 PC8 PC8 21'-0" 5'-0" DN UP 21'-0" ACCESSIBLE ROUTE AC C E S S I B L E R O U T E ACCESSIBLE ROUTE AC C E S S I B L E R O U T E AC C E S S I B L E R O U T E ACCESSIBLE ROUTE 5'-0" 5'-4" LA N D I N G LANDING 5' - 0 " LA N D I N G LANDING 5' - 0 " 5' - 0 " 23 ' - 5 " DN DN DN DN 36 ' - 3 " 17 ' - 2 " 8' - 5 " 13'-0"23'-2"34'-4"22'-8" 5'-6"2'-4"10'-10"41'-10"5'-0"10'-10" 7' - 6 " 6' - 3 " 5' - 0 " 7' - 9 " 6' - 0 " 5' - 0 " 24'-0"15'-10" 15'-0" 10'-6" 7' - 9 " 14 ' - 0 " 1 A2.4 6' - 3 " 6' - 3 " 3 4 4 4 5 6 7 7 7 8 8 8 9 9 9 2'-10" 20 ' - 4 " 15 ' - 9 " 15'-10" 3' - 0 " 7' - 6 " 14 ' - 5 " 5' - 0 " 17 ' - 3 " 6' - 0 " 15 ' - 3 " 21'-1"15'-8" 1 1 1 10 10 11 1 AD1 1 AD1 2'-0" CLR. 1' - 3 " 6'-10" 8'-9"8'-5"3'-0" NO COOKING DASHED LINE FOR PATH OF TRAVEL IS PROVIDED ON THE EGRESS PLAN SHEET 1 11 1 1 1 1 1 1 1 1 3 1 1 1 1 1 1 11 1 1 1 2 2 2 1 1 4 6 RECEIVERS 12 OCCUPANT LOAD SIGNAGE SEE 8/AD2 5 5 6 P.H. P.H. P.H. P.H. P.H. 33 2 2 1 4' - 9 " 4' - 9 " SINGLE PANEL DOOR INTERIORA DOUBLE PANEL DOOR INTERIORB SEE SCHEDULE SE E S C H E D U L E SEE SCHEDULE C SEE SCHEDULE SINGLE PANEL DOOR PANIC HARDWAREDDOUBLE PANEL DOOR PANIC HARDWARE SEE SCHEDULE FIXED WINDOW INTERIORA 3' - 0 " SE E S C H E D U L E SEE SCHEDULE SHEET# JOB# DRAWN DATE SCALE RE V I S I O N S DEC. 2025 YC24005 be r e p r o d u c e d w i t h o u t t h e w r i t t e n c o n s e n t o f Y N G A R C H I T E C T S , I N C . Th i s D o c u m e n t i s t h e p r o p e r t y o f Y N G A R C H I T E C T S , I N C . a n d s h a l l n o t CO P Y R I G H T C BL E S S E D I N T E R N A T I O N A L C H U R C H C H A N G E O F U S E 19 2 0 E 1 7 T H S T R E E T , S U I T E 2 0 0 19 2 0 E 1 6 T H S T R E E T SA N T A A N A , C A 9 2 7 0 5 T.I. PC 4 0 8 / 2 3 / 2 4 4T H S U B M I T T A L PC 5 1 0 / 0 2 / 2 4 5 T H S U B M I T T A L AR C H I T E C T S 15 2 4 B r o o k h o l l o w D r i v e , S u i t e 6 Sa n t a A n a , C A . 9 2 7 0 5 71 4 - 4 2 6 - 2 9 2 0 T . ww w . y n g a r c h i t e c t s . c o m R U.S. GREEN BU I LDING COUNCI L MEM B ER .\ S i g n a t u r e Y e n n y N g . j p g No . C - 3 2 7 9 8 HC F R A D SE N E S TAT L CA I OF E ILC A ORNITC ITE YE N N Y N G DA T E RE N E W A L 03 - 3 1 - 2 5 PC 6 0 6 / 1 6 / 2 5 O C F A S U B M I T T A L PC 7 1 0 / 2 9 / 2 5 7 T H S U B M I T T A L PC 8 12 / 2 / 2 5 8T H S U B M I T T A L PC 9 1 2 / 1 9/2 5 9T H S U B M I T T A L A2.1 PR O P O S E D S E C O N D F L O O R P L A N 1PROPOSED SECOND FLOOR PLAN SCALE: 1/8" = 1'-0" NORTH 1 (N) RAMP 2 3 4 (N) INTERIOR PARTITION - NON-FIRE-RATED 3-5/8" × 20 GA METAL STUDS @ 16" O.C., ½" GWB EACH SIDE. (NON-BEARING PARTITIONS) (N) DOOR (E) DOOR TO REMAIN (E) WALL TO REAMAIN FLOOR PLAN LEGEND DOOR SCHEDULE DOOR FRAME SYM SIZE COUNT TYPE MATERIAL FINISH MATERIAL FINISH COMMENT 1 3'-0"x8'-0" 24 A WOOD P WOOD P 2 6'-0"x8'-0" 3 B WOOD P WOOD P 3 3'-0"x8'-0" 1 C WOOD P WOOD P PANIC HARDWARE 4 6'-0"x8'-0" 1 D WOOD P WOOD P PANIC HARDWARE WINDOW SCHEDULE SYM SIZE COUNT TYPE HEADER MATERIAL U-VALUE SHGC COMMENT 1 6'-0"x4'-0" 3 A 8'-0" ALUM., DUAL PANEL 0.3 0.23 FIXED REQUIRED PLUMBING FIXTURES CALCULATION PER AREA PER TABLE 422.1 - CPC 2022 CLASSIFICA TION OCC. LOAD OCC. PER SEX WATER CLOSETS LAVATORIES URINAL DRINKING FOUN. MALE FEMALE MALE FEMALE MALE A3 268 134 1.34 (101-200) 1.34 (101-200) 0.67 (1-200) 1.34 (101-200) 1.34 (101-200) 0.54 (1-250) B 21 10.5 0.21 (1-50) 0.7 (1-15) 0.14 (1-75) 0.21 (1-50) 0.10 (1-100) 0.07 1 PER 150 S 11 5.5 0.055 (1-100) 0.055 (1-100) 0.27 (1-200) 0.27 (1-200) 0.54 (1-250) TOTAL REQUIRED TOTAL PROVIDED 1.6=2 3 2 4 1.08 4 1.8=2 4 1.4=2 2 1.1=2 2 OCCUPANCY LOADDOOR TYPE WINDOW & DOOR SCHEDULE WINDOW TYPE OCCUPANCY LOAD TABULATION PER TABLE 1004.5 - MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT ROOM AREA FACTOR REFRENCE OCC. CLASS OCCUPANT 1 SANCTUARY 3,250 FIXED GROSS A3 185 2 STAGE 533 15 NET A3 36 3 BREAK ROOM 436 15 NET A3 29 4 OFFICE 1 179 150 GROSS B 2 5 OFFICE 2 225 150 GROSS B 2 6 OFFICE 3 205 150 GROSS B 2 7 OFFICE 4 205 150 GROSS B 2 8 OFFICE 5 205 150 GROSS B 2 9 OFFICE 6 205 150 GROSS B 2 10 OFFICE 7 175 150 GROSS B 2 11 MEETING ROOM 262 15 NET A3 18 12 CRY ROOM 317 150 GROSS B 3 13 STREAMING TECH. BOOTH 71 150 GROSS B 1 14 TRANSLATION POD 71 150 GROSS B 1 15 A/V BOOTH 100 200 GROSS B 1 16 KITCHEN 313 200 GROSS B 2 17 GREEN ROOM 111 300 GROSS S 1 19 STORAGE 1 133 300 GROSS S 1 20 STORAGE 2 562 300 GROSS S 2 21 STORAGE 3 239 300 GROSS S 1 22 STORAGE 4 136 300 GROSS S 1 23 STORAGE 5 36 300 GROSS S 1 24 PANTRY 121 300 GROSS S 1 25 (E) STORAGE 65 300 GROSS S 1 26 (E) ELECTRICAL ROOM 121 300 GROSS S 1 TOTAL ALLOWABLE OCC. LOAD 8,155 299.0 FLOOR PLAN KEY NOTES (N) PLUMBING FIXTURES AND ACCESSORIES (E) STRUCTURAL COLUMN TO REMAIN. REFER TO STRUCTURE DWG. PLUMBING FIXTURE CALC. 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNER AND ALL THE UTILITY COMPANIES DEPARTMENTS 72 HRS OR AS REQUIRED BEFORE DEMOLITION IS TO START TO VERIFY ANY UTILITIES THAT MAY BE PRESENT ON SITE. ALL VERIFICATIONS, LOCATIONS, SIZE AND DEPTHS SHALL BE MADE BY THE APPROPRIATE UTILITY COMPANIES OR DEPARTMENTS. VERIFY THAT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING DEMOLITION OPERATIONS. 2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY WITH EACH COMPANY AND OR AGENT WHO IS RESPONSIBLE TO REMOVE OR RELOCATE EACH EXISTING UTILITY. IT FURTHER SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BEAR THE COST FOR THE REMOVAL, TERMINATION OR RELOCATION OF UTILITIES IF THE RESPONSIBILITY IS NOT COVERED BY THE UTILITY COMPANY. 3. PRIOR TO COMMENCEMENT OF WORKS THE CONTRACTOR SHALL EXAMINE MECHANICAL, ELECTRICAL AND PLUMBING WORKS CONCEALED WITHIN WALLS AND CEILING CAVITIES TO DETERMINE THE SCOPE OF SELECTED DEMOLITION. 4. PRIOR TO COMMENCEMENT OF WORKS THE CONTRACTOR SHALL REVIEW MATERIALS TO BE REMOVED WITH THE OWNER, TO IDENTIFY ITEMS THAT WILL BE TURNED OVER TO THE OWNER. MATERIALS TO BE SALVAGED WILL BE CAREFULLY REMOVED AND DELIVERED TO THE LOCATION INDICATED BY THE OWNER. 5. THE SITE SHALL BE STRIPPED OF EXISTING IMPROVEMENTS WITHIN THE PERIMETER CITY SIDEWALKS AND OWNERS PROPERTY. ALL MATERIALS FROM DEMOLITION SHALL BE REMOVED FROM THE SITE BY THE GENERAL CONTRACTOR UNLESS APPROVED FOR REUSE ON SITE BY THE STRUCTURAL, GEOTECHNICAL ENGINEERS AND GOVERNING AGENCIES. 6. ALL CONTRACTORS MUST TAKE PARTICULAR CARE WHEN EXCAVATIONS IN AND AROUND EXISTING UTILITY LINES AND EQUIPMENT. ACTUAL FIELD LOCATIONS OF ALL THE EXISTING UTILITIES ARE THE CONTRACTORS RESPONSIBILITY AND MUST BE LOCATED EITHER BY THE REPRESENTATIVE OF THE UTILITY COMPANY OR BY A PRIVATE UNDERGROUND UTILITY LOCATING COMPANY PRIOR TO START THE DEMOLITION ACTIVITIES. 7. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. PROMPTLY NOTIFY THE DESIGNERS OF ANY INCONSISTENCIES OR OTHER ISSUES IMMEDIATELY UPON DISCOVERY AND BEFORE PROCEEDING WITH THE WORK. 8. THE CONTRACTOR MUST VISIT THE SITE AND STUDY EXISTING PHYSICAL CONDITIONS, REVIEW DRAWINGS, AND REACH THEIR OWN CONCLUSIONS ON WORK NECESSARY TO ACCOMPLISH INTENDED RESULTS DESCRIBED BY THE PROJECT DOCUMENTS. 9. REMOVAL OF THE EXISTING IMPROVEMENTS SHALL BE AS REQUIRED FOR THE PROJECT. THE MATERIALS REMOVED FROM THE SITE SHALL BE DISPOSED OF IN A PROPER AND LEGAL MANNER PER FEDERAL, STATE AND OR LOCAL LAWS AND ORDINANCES. 10. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSPECT EACH DAY AND REMOVE ALL MUD, DIRT, GRAVEL AND LOOSE MATERIALS TRACKED, DUMPED, SPILLED OR WIND BLOWN FROM THIS SITE ONTO OTHER SITES, RIGHT OF WAYS, PUBLIC OR PRIVATE STREETS OR ROADS, DRIVEWAYS, YARDS OR SIDEWALKS. THE CONTRACTOR MUST CLEAN OR PICK UP DAILY IF NECESSARY. THE CONTRACTOR SHALL REDUCE AIRBORNE DUST DURING THE ENTIRE DEMOLITION SCHEDULE. WATER MAY BE USED AS A REDUCER. 11. IF ANY HAZARDOUS MATERIALS ARE ENCOUNTERED THE OWNER SHALL BE NOTIFIED. THOSE MATERIALS SHALL BE REMOVED AND DISPOSED OF IN A MANNER AS APPROVED BY ALL GOVERNING AGENCIES AND IN A LANDFILL OR DISPOSAL FACILITY LICENSED TO ACCEPT HAZARDOUS MATERIAL. 12. RECYCLED CRUSHED OR PULVERIZED CONCRETE OR MASONRY MAY BE USED AS BACKFILL OR IN NEW CONSTRUCTION ONLY IF APPROVED BY THE STRUCTURAL AND GEOTECHNICAL ENGINEER. 13. THE CONTRACTOR SHALL MAINTAIN EROSION CONTROL DEVICES AS REQUIRED DURING DEMOLITION. 14. AGGREGATE ACCESSORY OCCUPANCIES SHALL NOT OCCUPY MORE THAN 10 PERCENT OF THE FLOOR AREA OF THE STORY IN WHICH THEY ARE LOCATED AND SHALL NOT EXCEED THE TABULAR VALUES FOR NON-SPRINKLER BUILDINGS IN TABLE 506.2 FOR EACH SUCH ACCESSORY OCCUPANCY. (CBC 2022, 508.2.3) 15. NO COOKING IN THE PROVIDED KITCHEN. GENERAL NOTES (E) PLUMBING FIXTURES AND ACCESSORIES (N) TACTILE EXIT SIGN. RE. DETAIL 4/A2.4 (N) ISA SIGN AT 60" A.F.F. PER NOTE ON A0.18 (E) DOOR AND DOORWAY COMPLIED WITH ALL ACCESSIBILITY REQ. REFER TO A0.1 FOR DETAILS & NOTES9 5 (E) ELEVATOR TO REMAIN 6 (E) ROOF ACCESS LADDER TO REMAIN 7 (N) FIXED SEATING WITH ANCHOR ATTACH TO THE FLOOR JOIST. REFER TO SHEET A2.210 (N) ASSISTIVE LISTENING SYSTEM (ALS): 6 RECEIVERS PROVIDED. FOR DETAILS SEE 11/AD311 (N) OCCUPANT LOAD SIGNAGE. SEE SHEET AD2/812 TOTAL TENANT IMPROVEMENT ARE 10,390 SF (E) 2 HRS. FIRE WALL TEMPERED GLAZINGT 6 5 3'-0"x8'-0" 6'-0"x8'-0" EXISTING DOOR PANIC HARDWARE EXISTING DOOR PANIC HARDWARE 2 C D1 PC8PC7 ALL THE NEW INTERIOR WALLS ARE NON-BEARING PARTITIONS PC8 PC9 EXPOSED CLG. 13'-0" SANCTUARY EXPOSED CLG. 13'-0" GREEN ROOM 2 9'-0" STORAGE9'-0" MEN 9'-0" WOMEN 9'-0" STORAGE 9'-0" ELECTRICAL CLG. 13'-0" EXPOSED CLG. 13'-0" EXPOSED EXPOSED 13'-0" STORAGE 3 EXPOSED 13'-0" STORAGE 4 9'-0" CRY ROOM 9'-0" STREAM. TECH. 9'-0" TRANSLATOR 9'-0" A/V BOOTH 9'-0" OFFICE 1 9'-0" OFFICE 2 EXPOSED 13'-0" STORAGE 2 9'-0" OFFICE 4 9'-0" OFFICE 3 EXPOSED 13'-0" STORAGE 1 9'-0" OFFICE 6 9'-0" OFFICE 5 9'-0" HALLWAY 9'-0" HALLWAYEXPOSED 13'-0" BREAK ROOM 9'-0" KITCHEN 9'-0" OFFICE 7 9'-0" PANTRY 9'-0" ALL GENDER 1 9'-0" ALL GENDER 2 9'-0" MEETING 9'-0" STOR. 5 (N)(N) (N) (N) (E) (E)(E) (E) (E)(E) (E)(E) (E)(E) (E) (E) (E) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N)(N) (N)(N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N)(N) (N) (N)(N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N)(N) (N) (N)(N) DN 21" HEIGHT RAMP 8.33% 1" / 12" SHEET# JOB# DRAWN DATE SCALE RE V I S I O N S OCT. 2025 YC24005 be r e p r o d u c e d w i t h o u t t h e w r i t t e n c o n s e n t o f Y N G A R C H I T E C T S , I N C . Th i s D o c u m e n t i s t h e p r o p e r t y o f Y N G A R C H I T E C T S , I N C . a n d s h a l l n o t CO P Y R I G H T C BL E S S E D I N T E R N A T I O N A L C H U R C H C H A N G E O F U S E 19 2 0 E 1 7 T H S T R E E T , S U I T E 2 0 0 19 2 0 E 1 6 T H S T R E E T SA N T A A N A , C A 9 2 7 0 5 T.I. PC 4 08 / 2 3 / 2 4 4T H S U B M I T T A L PC 5 10 / 0 2 / 2 4 5T H S U B M I T T A L AR C H I T E C T S 15 2 4 B r o o k h o l l o w D r i v e , S u i t e 6 Sa n t a A n a , C A . 9 2 7 0 5 71 4 - 4 2 6 - 2 9 2 0 T . ww w . y n g a r c h i t e c t s . c o m R U.S. GREEN BU I LDING COUNCIL MEM B ER .\ S i g n a t u r e Y e n n y N g . j p g No . C - 3 2 7 9 8 HC F R A D SE N E S TAT L CA I OF E ILC A ORNITC ITE YE N N Y N G DA T E RE N E W A L 03 - 3 1 - 2 5 PC 6 06 / 1 6 / 2 5 OC F A S U B M I T T A L A2.2 P R O P O S E D R C P 1PROPOSED 2ND RCP SCALE: 1/8" = 1'-0" NORTH 2x4 LED LIGHT FIXTURE (E): EXISTING (N): NEW MECHANICAL REGISTER/DIFFUSER. REFER TO MECH. DWG. (E): EXISTING (N): NEW (N) 6" LED RECESSED DOWN LIGHTS (E) 2x4 CEILING GRID AND ACOUSTIC TILE TO REMAIN (N) EXIT SIGN, SEE GENERAL NOTE SYMBOL LEGENDS 1.NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL AND ELECTRICAL OR MECHANICAL DRAWINGS. OBTAIN CLARIFICATION FROM ARCHITECT IN WRITING BEFORE PROCEEDING WITH THE WORK IN QUESTION OR RELATED WORK. 2.WHEN CEILING INTERRUPTIONS OCCUR, SUCH AS PARTITIONS, FUR DOWNS ETC., CONTRACTOR SHALL CHECK AND VERIFY THAT WORK IS BUILD-ABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. SHOULD THERE BE ANY QUESTIONS, CONTRACTOR IS RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT IN WRITING BEFORE PROCEEDING WITH THE WORK IN QUESTION OR RELATED WORK. 3.ALL NEW CEILING FIXTURES, SWITCHES, AND MOTION SENSORS SHALL MATCH BUILDING STANDARD U.N.O. 4.LOCATE ALL LIGHT FIXTURES, SPEAKERS, ACCESS PANELS, LIFE-SAFETY FIXTURES, ETC., IN STRAIGHT LINES AND IN CENTER OF CEILING TILES U.N.O. 5.THERE SHALL BE NO COMBUSTIBLE MATERIALS IN THE PLENUM SPACE INCLUDING ALUMINUM FLEX, ALUMINUM CONDUITS, AND POT METAL LINE OF FINISH CEILING. 6.ALL NEW CONDUITS BOXES, DUCTS, HVAC UNITS, PIPES, ETC. SHALL BE INSTALLED AS HIGH AS POSSIBLE, NOT LOWER THAN 8" ABOVE LINE OF FINISH CEILING. 7.WHEN FIXTURES INTERRUPT MAIN RUNNERS, CUT AND REINFORCE AS REQUIRED. 8.ALL FLUORESCENT FIXTURE LAMPS SHALL BE IDENTICAL FROM ONE MANUFACTURER. 9.PROVIDE EMERGENCY LIGHTING LEVELS AS REQUIRED BY CODE. 10.THE CONTRACTOR SHALL PROVIDE RECORD DOCUMENTS OF ALL WORK PREFORMED AND SHALL INDICATE ANY DEVIATIONS FROM THE DESIGN DOCUMENTS AS WELL AS THE LOCATION OF ALL WORK WHICH IS HIDDEN BY SUBSEQUENT CONSTRUCTION. THE RECORD DOCUMENTS SHALL BE GIVEN TO THE OWNER AT COMPLETION OF TENANT CONSTRUCTION PRIOR TO APPLICATION FOR FINAL PAYMENT. 11.TACTILE EXIT SIGNS SHALL BE REQUIRED AT THE FOLLOWING LOCATIONS: -EACH GRADE-LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT WITH THE WORD "EXIT." -EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY, WHICH IS REQUIRED TO HAVE A VISUAL EXIT SIGN, SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE." -EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED BY A SIGN WITH THE WORDS "TO EXIT." GENERAL NOTES (N) 24" CIRCULAR LED PENDANT LIGHT (N) 2x4 LED PENDANT LIGHT (N) 2x4 CEILING GRID AND ACOUSTIC TILE, REFER TO (N) 2x2 CEILING GRID AND ACOUSTIC TILE, REFER TO 2FIXED SEAT CONNECTION SCALE: N.T.S (N) EMERGENCY SECONDARY POWER LIGHTING REF NO T I N S C O P E EX I S T I N G O F F I C E F O R N O N P R O F I T OR G A N I Z A T I O N O N F I R S T F L O O R NO A S S E M B L Y U S E 249 SF GREEN ROOM 121 SF ELECTRICAL 533 SF STAGE 313 SF KITCHEN 25 SF STORAGE MEN WOMEN 40 SF STORAGE 2 RISERS @ 7" MAX 2 RISERS @ 7" MAX 3,250 SF SANCTUARY ALL GENDER 1 ALL GENDER 2 121 SF PANTRY 278 SF MEETING435 SF BREAK ROOM 175 SF OFFICE 7 239 SF STORAGE 3 136 SF STORAGE 4 205 SF OFFICE 1 71 SF STREAMING TECH.100 SF AV BOOTH 71 SF TRANSLATOR 205 SF OFFICE 3 205 SF OFFICE 4 317 SF CRY ROOM 562 SF STORAGE 2 133 SF STORAGE 1 205 SF OFFICE 2 225 SF OFFICE 6 179 SF OFFICE 5 36 SF STOR. 5 REF UNUSED PLACE B OCCUPANCY NO ASSEMBLY USE 1'-6"1'-6" T T UP UP UP UP 11'-4" 10' MIN. FIRE SEPARATION DISTANCE 10 ' - 1 0 " 10 ' - 1 0 " ACCESSIBLE ROUTE AC C E S S I B L E R O U T E ACCESSIBLE ROUTE AC C E S S I B L E R O U T E 3' - 0 " OP E N I N G NOT IN SCOPE A3 A3 PLEASE SEE SHEET A2.3 2ND FLOOR EGRESS PLAN FOR OCCUPANCY 1 DN DN DNDN ACCESSIBLE ROUTE AC C E S S I B L E R O U T E 36" 21" HEIGHT RAMP 8.33% 1" / 12" 84'-4" B E T W E E N E X I T D O O R 70'- 3 " B E T W E E N D I S T A N C E S E R V E D E-1 E-2 E-4 E-5 E-7 E-3 18 ' - 1 1 " 14'-6" 15 ' - 5 " 15'-3" EXI T .... . . . . . . .. . . . . . . 13'-4" 7'-1" TD3 TD8TD10 TD16 TD23 TD14 TD11 TD13 TD24 TD25 TD20 TD19 TD21 TD26 TD1 EXIT .... ... ..... ... ... EXIT .... ... ..... ... ... EXIT .... ... ..... ... ... EXIT .... ... ..... ... ...TD12 TD9 TD18 TD22 TD17 TD15 TD4 TD2 TD5 TD6 11 ' - 2 " 13'-10" 10 ' - 4 " 20'-1" 7' - 0 " 4' - 7 " 14'-2"10'-7"8'-1" 9' - 5 " 11 ' - 1 " 18'-1" 9'-5" 21 ' - 1 1 " 13 ' - 1 " 16'-6"4'-2"21'-2" 4'-6 " 8' - 0 " 3' - 9 " 18'-1" 10 ' - 6 " 18'-1" 10 ' - 6 " 11'-0" 14 ' - 6 " 14 ' - 6 " 11'-0" 11'-0" 14 ' - 6 " 14 ' - 6 " 17'-10" 8' - 1 1 " 19'-7" 1' - 7 " 6'-6"9'-6" 10 ' - 7 " 9'-6" 5' - 3 " 8'-2" 6' - 6 " 8'-0" 11 ' - 8 " 27'-9"17'-2" 9' - 9 " 12 ' - 8 " 9'-6" 10 ' - 7 " 4' - 1 1 " 9'-6" EXIT .... ... ..... ... ... TD7TD27 27'-6" 24 ' - 1 0 " EXTERIOR EXIT STAIRWAY 1 EXTERIOR EXIT STAIRWAY 2 EXTERIOR EXIT STAIRWAY 3 EX I T SI G N EX I T SI G N 4' - 1 0 " 27'-5" 4' - 9 " 25'-3" 34 ' - 8 " 19 ' - 9 " 4'-10" 5' - 1 " 32'-6"9'-10" 14 ' - 1 1 " 10'- 1 0 " 10'- 1 0 " 26'-11" 3' - 1 0 " 17'-6 " 8' - 2 " 18'-10"18'-10" 8' - 2 " 21'-2 " 7' - 0 " 12 ' - 1 1 " 17'-10" EXIT SIGN 6'-3" 5'-8" 2' - 1 0 " 8' - 3 " 2' - 6 " 10 ' - 2 " 18'-10"3'-7" 6' - 6 " 10 ' - 5 " 14'-8" 23'-0" 9' - 7 " 19 ' - 4 " 24'-9" 13' - 1 1 " 3'-5 " 2222 2121 22 1 23 62 62 2 2 1 1 1 3 3 83 61 1 1 REQ. REQ. REQ. 2 2 2 2 12 REQ. EXIT EXIT EXIT ACCESSIBLE EGRESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT ACCESS EXIT EXIT EXIT EXIT DISCHARGE ON THE FIRST FLOOR EXIT DISCHARGE ON THE FIRST FLOOR EXIT EXIT 1'-6" 6'-0" EX I T SI G N EXITSIGN EXITSIGNEXIT SIGN EXIT .... ... ..... ... ... EXIT SIGN UL 924 PHOTOLUMINESCENT (SEE KEY NOTES) PATH OF EGRESS E-1/...2 EXISTING EXIT DOOR DOOR WIDTH REQUIRED DOOR WIDTH PROVIDED NO. OF OCCUPANTS EXITING INDIVIDUAL ROOM OCCUPANT LOADX SHEET# JOB# DRAWN DATE SCALE RE V I S I O N S OCT. 2025 YC24005 be r e p r o d u c e d w i t h o u t t h e w r i t t e n c o n s e n t o f Y N G A R C H I T E C T S , I N C . Th i s D o c u m e n t i s t h e p r o p e r t y o f Y N G A R C H I T E C T S , I N C . a n d s h a l l n o t CO P Y R I G H T C BL E S S E D I N T E R N A T I O N A L C H U R C H C H A N G E O F U S E 19 2 0 E 1 7 T H S T R E E T , S U I T E 2 0 0 19 2 0 E 1 6 T H S T R E E T SA N T A A N A , C A 9 2 7 0 5 T.I. PC 4 08 / 2 3 / 2 4 4T H S U B M I T T A L PC 5 10 / 0 2 / 2 4 5T H S U B M I T T A L AR C H I T E C T S 15 2 4 B r o o k h o l l o w D r i v e , S u i t e 6 Sa n t a A n a , C A . 9 2 7 0 5 71 4 - 4 2 6 - 2 9 2 0 T . ww w . y n g a r c h i t e c t s . c o m R U.S. GREEN BU I LDING COUNC IL MEM B ER .\ S i g n a t u r e Y e n n y N g . j p g No . C - 3 2 7 9 8 HC F R A D SE N E S TAT L CA I OF E ILC A ORNITC ITE YE N N Y N G DA T E RE N E W A L 03 - 3 1 - 2 5 PC 6 06 / 1 6 / 2 5 OC F A S U B M I T T A L A2.3 M E A N S O F E G R E S S MAIN TRAVEL DISTANCE 12ND FLOOR MEANS OF EGRESS PLAN SCALE: 1/8" = 1'-0" NORTH E-1 TO E-4 = 91'-11" DIAGONAL AREA OF SERVICE = 160'-1" THE MINIMUM SEPARATION BETWEEN REQUIRED EXIT ACCESS DOORS OR EXITS SHALL BE EQUAL OR GREATER THAN 1/2 THE DIAGONAL OF THE SPACE OR FLOOR IT SERVES IN NOT SPRINKLER BUILDINGS. PROPOSED DISTANCES BETWEEN DOORS ARE GREATER THAN MINIMUM REQUIRED. EXIT DOOR DISTANCE L.T.R.=LESS THAN REQUIRED (<200' PER TABLE 1016.2, EXIT ACCESS TRAVEL DISTANCE) TD1 -> E-3 (STAIR 1) (10'-6" + 18'-1" + 11'-9" + 18'-5" + 10'-10" + 34'-8" + 3'-10" + 26'-11" + 17'-10" + 2'-6")= 155'-4" (L.T.R.) (STAIR 2) (10'-6" + 18'-1" + 11'-9" + 18'-5" + 10'-10" + 25'-3" + 4'-5" = 99'-3" (L.T.R.) TD2 -> E-5 (STAIR 1) (9-6" + 10'-7" 6'-6" + 19'-1" + 17'-10" + 2'-6")= 66'-0" (L.T.R.) TD3 -> E-5 (STAIR 1) (15'-3" + 33'-10" + 20'-4")= 69'-5" (L.T.R.) TD4 -> E-5 (STAIR 1) (16'-0" + 19'-1" + 20'-4")= 55'-5" (L.T.R.) TD5 -> E-5 (STAIR 1)(17'-2" + 9'-4" + 20'-4")= 67'-2" (L.T.R.) TD6 -> E-5 (STAIR 1)(27'-9" + 9'-4" + 20'-4")= 57'-5" (L.T.R.) TD7 -> E-5 (STAIR 1)(14'-6" + 36'-1" + 20'-4")=70'-11" (L.T.R.) TD8 -> E-5 (STAIR 1)(8'-0" + 17'-0" + 19'-7" + 20'-8" + 20'-4")= 85'-8" (L.T.R.) TD9 -> E-4 (STAIR 1)(9'-6" + 10'-7" + 18'-11" + 7'-0" + 7'-1" +19'-4" + 13'-4" + 3'-10" + 26'-11" +17'-10" + 2'-6")= 136'-10" (L.T.R.) TD10 -> E-4 (STAIR 1)(4'-11" + 9'-6" + 25'-11" + 7'-1" + 19'-4" + 13'-4" + 3'-10" + 26'-11" + 17'-10" + 2'-6")= 141'-1" (L.T.R.) TD11 -> E-1 (STAIR 3)(10'-2" + 18'-10" + 3'-7" + 17'-6" + 19'-9" + 6'-3" + 9'-7" + 5'-8" + 2'-10")= 93'-11" (L.T.R.) -> E-4 (STAIR 1)(24'-10" + 20'-1" + 9'-10" + 13'-4" + 3'-10" + 26'-11" + 17'-10" + 2'-6")= 119'-2" (L.T.R.) TD12 -> E-1 (STAIR 3)(10'-4" + 13'-10" + 6'-3" + 9'-7" + 5'-8" + 2'-10")=48'-6" (L.T.R.) TD13 -> E-1 (STAIR 3)(9'-9" + 11'-2" + 6'-3" + 9'-7" + 5'-8" + 2'-10") = 47'-3" (L.T.R.) TD14 -> E-1 (STAIR 3)(5'-1" + 4'-10" + 12'-11" + 19'-9" + 6'-3" + 9'-7" + 5'-8" +2'-10")= 67'-2" (L.T.R.) TD15 -> E-1 (STAIR 3)(32'-6" + 8'-3" + 5'-1" + 4'-10" + 12'-11" +19'-9" +6'-3" + 9'-7" +5'-8" + 2'-10")= 107'-8" (L.T.R.) -> E-4 (STAIR 1)(20'-1" + 9'-10" + 13'-4" + 3'-10" + 26'-11" + 17'-10" + 2'-6") = 94'-4" (L.T.R.) -> E-3 (STAIR 2) (20'-1" + 14'-10" + 3'-9" + 8'-0" + 4'-6" + 17'-4" + 10'-10" + 25'-3" + 4'-5") = 109'-0" (L.T.R.) TD16 -> E-4 (STAIR 1)(19'-4" + 13'-4" + 3'-10" + 26'-11" + 17'-10" + 2'-6")= 83'-9" (L.T.R.) TD17 -> E-3 (STAIR 1) (10'-6" + 18'-1" + 8'-0" + 18'-5" + 10'-10" + 34'-8" + 3'-10" + 26'-11" + 17'-10" + 2'-6")= 151'-7" (L.T.R.) (STAIR 2) (10'-6" + 18'-1" + 8'-0" + 18'-5" + 10'-10" + 25'-3" + 4'-5")= 95'-6" (L.T.R.) TD18 -> E-3 (STAIR 2)(8'-11" + 17'-10" + 14'-6" + 21'-2" + 13'-11" + 3'-5" + 40'-6")= 120'-3" (L.T.R.) TD19 -> E-3 (STAIR 2)(11'-0" + 14'-6" + 21'-2" + 13'-11" + 3'-5" + 40'-6")= 104'-6" (L.T.R.) TD20 -> E-3 (STAIR 2)(11'-0" + 14'-6" + 25'-4" + 13'-11" + 3'-5" + 40'-6")= 108'-8" (L.T.R.) TD21 -> E-3 (STAIR 2)(11'-0" + 14'-6" + 25'-4" + 13'-11" + 3'-5" + 40-6")= 108'-8" (L.T.R.) TD22 -> E-3 (STAIR 2)(4'-4" + 8'-1" + 18'-5" + 41'-10" + 13'-11" + 3'-5" + 40'-6")= 130'-9" (L.T.R.) TD23 -> E-3 (STAIR 2)(7'-1" + 18'-9"+ 18'-5" + 41'-10" + 13'-11" + 3'-5" + 40'-6")= 143'-8" (L.T.R.) TD24 -> E-3 (STAIR 2)(32'-9" + 18'-5" + 41'-10" + 13'-11" + 3'-5" + 40'-6")= 144'-10" (L.T.R.) TD25 -> E-2 (STAIR 2)(9'-5" + 21'-11" + 4'-10" + 27'-5" + 4'-9" + 4'-5")= 72'-9" (L.T.R.) TD26 -> E-4 (11'-1" + 18'-1" + 13'-1" + 41'-10" + 13'-11" + 3'-5" + 10'-10" + 25'-3" + 4'-5")= 141'-11" (L.T.R.) TD27 -> E-1 (STAIR 3)(6'-6" + 10'-5" + 14'-8" + 13'-3" + 9'-9" + 11'-2" + 6'-3" + 9'-7" + 5'-8" + 2'-10") = 90'-1" (L.T.R) -> E-4 (STAIR 1)(6'-6" + 18'-10" + 8'-2" + 21'-2" + 7'-0" + 7'-1" + 19'-4" + 13'-4" + 3-'10" + 26'-11" + 17'-10" + 2'-6")= 152'-6"(L.T.R) -> E-1 (STAIR 3)(6'-6" + 10'-5" + 14'-8" + 13'-3" + 9'-9" + 11'-2" + 6'-3" + 9'-7" + 5'-8" + 2'-10")= 90'-1" (L.T.R.) -> E-1 (STAIR 1)(6'-6" + 10'-5" + 27'-6" + 9'-6" + 10'-7" + 18'-11" + 7'-0" + 7'-1" + 19'-3" +13'-4" + 3'-10" + 26'-11" + 17'-10" + 2'-6") =181'-3" (L.T.R.) MEANS OF EGRESS NOTES 1.ALL MEANS OF EGRESS DOORS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 1010.1. THE FORCE FOR PUSHING OR PULLING OPEN INTERIOR SWINGING EGRESS DOORS, OTHER THAN FIRE DOORS, SHALL NOT EXCEED 5 POUNDS. FOR OTHER SWINGING DOORS, AS WELL AS SLIDING AND FOLDING DOORS, THE DOOR LATCH SHALL RELEASE WHEN SUBJECTED TO A 15-POUND FORCE. THE DOOR SHALL BE SET IN MOTION WHEN SUBJECTED TO A 30-POUND FORCE. THE DOOR SHALL SWING TO A FULL OPEN POSITION WHEN SUBJECTED TO A 15-POUND FORCE. REVOLVING AND SLIDING DOORS MAY BE USED IN OTHER THAN GROUP H OCCUPANCIES AS EGRESS DOORS ONLY IF ALL OF THE REQUIREMENTS OF SECTION 1010.1.4.1 AND SECTION 1010.1.4.3, RESPECTIVELY, ARE MET. 2.SHOW CLEARLY THAT PANIC AND FIRE EXIT HARDWARE, WHERE INSTALLED ON DOORS IN THIS BUILDING. SATISFY THE FOLLOWING: (1008.1.10) A.THE ACTUATING PORTION OF THE RELEASING DEVISE SHALL EXTEND AT LEAST ONE-HALF OF THE DOOR LEAF WIDTH. B.THE MAXIMUM UNLATCHING FORCE DOES NOT EXCEED 15-POUND C.PIVOTED OR BALANCED DOORS SHALL BE OF THE PUSH-PAD TYPE WHERE PANIC HARDWARE IS REQUIRED, AND THE PAD SHALL NOT EXTEND ACROSS MORE THAN ON HALF OF THE FLOOR WIDTH, MEASURED FROM THE LATCH SIDE. D.PANIC HARDWARE IS LISTED IN ACCORDANCE WITH UL 305. E.FIRE EXIT HARDWARE IS LISTED IN ACCORDANCE WITH UL 10C AND UL 305 3.EXIT SIGN SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. INTERNALLY ILLUMINATED EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND CHAPTER 27. EXTERNALLY ILLUMINATED EXITS SIGNS SHALL COMPLY WITH THE GRAPHICS AND POWER SOURCE REQUIREMENTS IN SECTIONS 1013.6.1 AND 1011.6.3, RESPECTIVELY. WHEN THE FACE OF AN EXIT SIGN IS ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE AN INTENSITY OF NOT LESS THAN 5-FOOT CANDLE (54LUX). (1013.3). 4.ANY TIME A BUILDING OR A PORTION OF A BUILDING IS OCCUPIED, THE MEANS OF EGRESS SERVING THE OCCUPIED PORTION SHALL BE ILLUMINATED AT AN INTENSITY OF NOT LESS THEN 1-FOOT CANDLE (11LUX) AT THE WALKING SURFACE LEVEL.. 5.THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED BY THE PREMISE'S ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY SYSTEM FOR THE FOLLOWING AREAS: A.AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE TWO OR MORE MEANS OF EGRESS. B.CORRIDORS, INTERIOR EXIT STAIRWAYS AND RAMPS, AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO HAVE TWO ORE MORE EXITS. C.EXTERIOR EGRESS COMPONENTS AT OTHER THAT THE LEVEL OF EXIT DISCHARGE UNTIL EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS REQUIRE TO HAVE TWO OR MORE EXITS. D.INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN SECTION 1028.1, IN BUILDINGS REQUIRE TO HAVE TWO OR MORE EXITS. E.EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1010.1..6, FOR EXIT DISCHARGE DOORWAYS IN BUILDINGS REQUIRE TO HAVE TWO OR MORE EXITS. 6.THE EMERGENCY POWER SYSTEM SHALL ALSO BE CONNECTED TO AN EMERGENCY ELECTRICAL SYSTEM WHICH IS TO PROVIDE CONTINUED ILLUMINATION FOR A DURATION OF NOT LESS THAN 1-1/2 HR. IN CASE OF PRIMARY POWER LOSS. CONTINUED ILLUMINATION IS TO BE PROVIDED FROM STORAGE BATTERIES, UNIT EQUIPMENT, OR AN ON-SITE GENERATOR AND THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH CHAPTER 27. (1008.3.4). 7.EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1-FOOT CANDLE (11LUX) AND A MINIMUM AT ANY POINT OF 0.1-FOOT CANDLE (1LUX) MEASURE ALIGN THE PATH OF EGRESS AT FLOOR LEVEL. A MAXIMUM-TO-MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. (1008.3.5). 8.WHERE KEY-OPERATED LOCKING DEVICES ARE USED, POST A SIGN ON OR ADJACENT TO THE REQUIRED MAIN EXIT DOOR WITH 1-IN. LETTERING STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." (1008.1.9.3). 9.EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY SPECIAL KNOWLEDGE, OR EFFORT. DOOR HANDLES, PULL, LATCHES, LOCKS, AND OTHER OPERATING DEVICES SHALL BE INSTALLED 34 TO 48 IN. ABOVE THE FINISHED FLOOR. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. SYMBOL LEGENDS 5'-0" A AD4 A AD4 B AD1 B AD1 1 AD2 1 AD2 1 AD2 10 AD2 DN DN AC C E S S I B L E R O U T E 5' - 0 " 5'-0" 1'-1"21'-0"1'-0" RAMP 1" / 12" STORAGE 3 ø 5 ' - 0 " A AD1 A AD1 249 SF GREEN ROOM STORAGE 4 B AD1 B AD1 10 AD2 1 AD2 1 AD210 AD2 DN DN 1'-1"1'-10" 1'-1" 2'-0" CLR. 7" MA X 5'-0" 5' - 0 " LA N D I N G 5'-0" 6'-10" 8' - 0 " 1' - 9 " 5'-0" LANDING 11" 7" 1'-0" 1'-0" MIN. MA X . HE I G H T EXISTING FLOOR 3 AD2 1' - 9 " 6" 11" MIN. 7" MA X . HE I G H T EXISTING FLOOR 3 AD2 1'-0" 4'-9" 1'-0" SHEET# JOB# DRAWN DATE SCALE RE V I S I O N S OCT. 2025 YC24005 be r e p r o d u c e d w i t h o u t t h e w r i t t e n c o n s e n t o f Y N G A R C H I T E C T S , I N C . Th i s D o c u m e n t i s t h e p r o p e r t y o f Y N G A R C H I T E C T S , I N C . a n d s h a l l n o t CO P Y R I G H T C BL E S S E D I N T E R N A T I O N A L C H U R C H C H A N G E O F U S E 19 2 0 E 1 7 T H S T R E E T , S U I T E 2 0 0 19 2 0 E 1 6 T H S T R E E T SA N T A A N A , C A 9 2 7 0 5 T.I. PC 4 0 8 / 2 3 / 2 4 4T H S U B M I T T A L PC 5 1 0 / 0 2 / 2 4 5T H S U B M I T T A L AR C H I T E C T S 15 2 4 B r o o k h o l l o w D r i v e , S u i t e 6 Sa n t a A n a , C A . 9 2 7 0 5 71 4 - 4 2 6 - 2 9 2 0 T . ww w . y n g a r c h i t e c t s . c o m R U.S. GREEN BU I LDINGCOUNC IL MEM B ER .\ S i g n a t u r e Y e n n y N g . j p g No . C - 3 2 7 9 8 HC F R A D SE N E S TAT L CA I OF E ILC A ORNITC ITE YE N N Y N G DA T E RE N E W A L 03 - 3 1 - 2 5 PC 6 06 / 1 6 / 2 5 OC F A S U B M I T T A L AD1 AR C H I T E C T U R A L D E T A I L S SCALE 3 8" = 1'-0"2SECTION A-A SCALE 3 8" = 1'-0"1STAIRS AT STAGE RIGHT SIDESCALE 3 8" = 1'-0"3RAMP AND STAIRS AT STAGE LEFT SIDE SCALE 3 8" = 1'-0"4SECTION B-B 1'-0"21'-0"1'-1" 1" 12" 1' - 9"WALL MOUNTED HANDRA I L 1 AD2 34 " - 3 8 " 1.MAX. HEIGHT OF THE 20 GAUGE 3-5/8" STEEL STUDS 16" O.C. 2.5-1/2" GLASS FIBER INSULATION 3.1/2" GYPSUM BOARD APPLIED VERTICALLY OR HORIZONTALLY WITH VERTICAL JOINTS CENTERED OVER STUDS AND FASTENED TO STUDS AND TRACKS WITH 1" TYPE S SCREWS 24" O.C. 4.JOINT TAPE AND COMPOUND OVER JOINTS AND FASTENER HEADS 24"24" 1 2 3 4 JAMB HEADER TRACKS INFILL STUD ADDITIONAL ANCHORAGE @ JAMB CRIPPLE STUD STUD TRACK SCREW EACH SIDE SHEET# JOB# DRAWN DATE SCALE RE V I S I O N S DEC. 2025 YC24005 be r e p r o d u c e d w i t h o u t t h e w r i t t e n c o n s e n t o f Y N G A R C H I T E C T S , I N C . Th i s D o c u m e n t i s t h e p r o p e r t y o f Y N G A R C H I T E C T S , I N C . a n d s h a l l n o t CO P Y R I G H T C BL E S S E D I N T E R N A T I O N A L C H U R C H C H A N G E O F U S E 19 2 0 E 1 7 T H S T R E E T , S U I T E 2 0 0 19 2 0 E 1 6 T H S T R E E T SA N T A A N A , C A 9 2 7 0 5 T.I. PC 4 0 8 / 2 3 / 2 4 4T H S U B M I T T A L PC 5 1 0 / 0 2 / 2 4 5T H S U B M I T T A L AR C H I T E C T S 15 2 4 B r o o k h o l l o w D r i v e , S u i t e 6 Sa n t a A n a , C A . 9 2 7 0 5 71 4 - 4 2 6 - 2 9 2 0 T . ww w . y n g a r c h i t e c t s . c o m R U.S. GREEN BU I LDINGCOUNC IL MEM B ER .\ S i g n a t u r e Y e n n y N g . j p g No . C - 3 2 7 9 8 HC F R A D SE N E S TAT L CA I OF E ILC A ORNITC ITE YE N N Y N G DA T E RE N E W A L 03 - 3 1 - 2 5 PC 6 06 / 1 6 / 2 5 OC F A S U B M I T T A L PC 7 1 0 / 2 9 / 2 5 7 T H S U B M I T T A L PC 8 12 / 2 / 2 5 8T H S U B M I T T A L PC 9 1 2 / 1 9/2 5 9T H S U B M I T T A L AD4 AR C H I T E C T U R A L D E T A I L S SCALE 1/4" = 1'-0"1RAMP AT STAGE - SECTION A-A SCALE N.I.S.4RAMP HANDRAIL HEIGHT AND CLEARANCE SCALE 1 1/2" = 1'-0"2INTERIOR PARTITION - STEEL STUD (NON-LOAD-BEARING) 1:12 MAXIMUM SLOPE SCALE N.I.S.6NON-BEARING INTERIOR WALL FRAMED TO CEILING SCALE N.I.S.6NON-BEARING STUD TO TRACK CONNECTION PC9 PC8 PC8 PC8 SCALE 3 8" = 1'-0"3HANDRAILS: CROSS SECTION