Loading...
HomeMy WebLinkAbout3401 S Harbor Blvd - PlanS H A R B O R B L V D W MACARTHUR BLVD W LAKE CENTER DR OWNER: KAISER FOUNDATION HEALTH PLN INC APN: 414-262-08 OWNER: PRICE REIT INC APN: 414-262-09 OWNER: OC CONSTELLATION LLC APN: 414-262-03 OWNER: CCF PS III HARBOR LLC APN: 414-261-07 OWNER: LAKE CENTER BUSINESS PARK OWNERS ASSN APN: 414-261-31 STORM DRAIN EASEMENT T ONLY EV CHARGING ONLY EV CHARGING NO PARKING SEBSEBSEB SEBSEBSEB SEBSEBSEB SEB SEB SEB SEB SEB NO PARKING NOPARKING NOPARKING RS RS RS NO PA R K I N G BO BO RS RS RS NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G RS NO P A R K I N G NO P A R K I N G PROJECT LOCATION. SEE SITE PLAN ON SHEET C3.0 & ELECTRICAL CONDUIT PLAN ON SHEET E1.0 STORM DRAIN EASEMENT STORM DRAIN EASEMENT LANDSCAPE EASEMENT OWNER: ICON OWNER POOL I LA BUSINESS PARKS LLC APN: 414-221-09 OWNER: RITTERMAL NANCY J TR APN: 414-221-14 OWNER: RITTERMAL NANCY J TR DEL TACO INC APN: 414-221-15 OWNER:ICON OWNER POOL I LA BUSINESS PARKS LLC APN:414-141-19 NO PARCEL INFORMATION AT THIS LOCATION OWNER: C J SEGERSTROM & SONS APN: 415-051-04 OWNER: MESA CONSOLIDATED WATER DISTRICT APN: 415-041-09 OWNER: ZERO IMPACT PROPERTIES LLC APN: 415-041-07 OWNER: HARBOR CAL-WESTERN / MACARTHUR DEV PARTNERS APN: 415-041-06 OWNER: SCHIFFMAN TODD I TR T I SCHIFFMAN LIVING TR APN: 415-041-05 T ONLY EV CHARGING ONLY EV CHARGING NO PARKING SEBSEBSEB SEBSEBSEB SEBSEBSEB SEB SEB SEB SEB SEB (BM 1 0 0 . 0 0 ) 99.77 100.11 100.00 NO PARKING NO PARKING NO PARKING RS RS RS NO PA R K I N G BO BO RS RS RS NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G RS NO P A R K I N G NO P A R K I N G Date Signed: 06-17-2025 SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ s i 0 1 . d w g ; La y o u t 1 - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 6 p m 00002112309PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 2 OVERALL SITE PLAN C1.0 0 25 50 100 150 200 SCALE IN FEET SCALE: 1"=100' SYMBOL LEGEND: EXISTING CENTER/SECTION LINE EXISTING EASEMENT LINE EXISTING PROPERTY LINE EXISTING PATH OF TRAVEL PROPOSED ACCESSIBLE ROUTE AREA OF WORK A C1.0 ENLARGED ACCESSIBLE ROUTE SCALE: 1"=30' (BM 1 0 0 . 0 0 ) 99.77 100.11 100.00 NO PARKING NO PARKING NO PARKING RS RS RS NO PA R K I N G LP BO BO LP RS RS RS NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G LP FIP EPB PIV WV IVAIVA LP EPB IVA LP EPB CVA WV IVA CVA RS EXISTING SOLAR CANOPY EXISTING SOLAR CANOPY EXISTING SCE VAULT, P544638 EXISTING SCE TRANSFORMER, P5510319 NO P A R K I N G NO P A R K I N G AL AL ALET EPB EXISTING INVERTER MOUNTED ON I-BEAM (TYP) CPB W W W E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD E E E UNK UNK UN K UN K UN K UNK UN K C C C C C C C C C C C C C C C C C C E E E E E E E E E E E IR R IR R IR R IR R IRR IRR IRR IRR IRR IRR IRR IRR IR R IR R IR R IR R IR R IRR IR R UNK UNK UNK UNK UNK UNK E E E E E E E E E E SD SD W W W W W E E E E E E E E E C C C C C C C C 1 2 11 15 1 1 3 (TYP) 3(TYP) 4 (TYP) 4(TYP) 7 7 7 7 7 7 7 7 7 6 8 9 10 10 1010 11 15 14 121213 (TYP) (TYP) 13 (TYP) 5 Date Signed: 06-17-2025 SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ t s 0 1 . d w g ; La y o u t 1 - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 6 p m 00002112309PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 SCALE IN FEET 0 5 10 20 SCALE: 1"=10' TOPOGRAPHIC LEGEND: BENCHMARK SURVEY CONTROL POINT ACCENT LIGHT BOLLARD COMMUNICATION PULL BOX COMMUNICATION VAULT ELECTRICAL TRANSFORMER ELECTRICAL PULL BOX FIRE HYDRANT FIRE INDICATOR POST INTERNATIONAL SYMBOL OF ACCESSIBILITY IRRIGATION VALVE LIGHT POST POST INDICATOR VALVE ROOF SUPPORT SIGN STORM DRAIN GRATE TREE; SPREAD SHOWN GRAPHICALLY WATER VALVE WHEELSTOP EXISTING ASPHALT CONCRETE PAVEMENT EXISTING BUILDING EXISTING CONCRETE EXISTING TRUNCATED DOMES BUILDING OVERHANG STRIPING COMMUNICATION LINE ELECTRICAL LINE IRRIGATION LINE JOINT TRENCH LINE STORM DRAIN LINE UNKNOWN UTILITY LINE WATER LINE (BM100.00) 100.11 AL BO CPB CVA ET EPB FIP IVA LP PIV RS WV 3TOPOGRAPHIC SURVEY & DEMOLITION PLAN C2.0 DEMOLITION NOTES: 1.THE "LIMIT OF DEMOLITION" SHOWN IS APPROXIMATE AND IS GENERALLY CONSIDERED TO BE THE MINIMUM REMOVAL REQUIREMENTS. CONTRACTOR MUST COORDINATE AS NOTED IN THE LEGEND. 2.CONTRACTOR SHALL LEGALLY DISPOSE OF ALL DEMOLISHED MATERIALS OFF SITE. 3.CONTRACTOR SHALL PROTECT ALL EXISTING UTILITY IMPROVEMENTS NOT SPECIFICALLY DESIGNATED FOR REMOVAL. 4.THE ON-SITE UNDERGROUND UTILITIES SHOWN ON THIS SHEET ARE AT AN APPROXIMATE LOCATION. THE EXTENT, LOCATIONS AND SIZES ARE UNKNOWN. THE CONTRACTOR SHALL POTHOLE TO LOCATE AND VERIFY THE UNDERGROUND UTILITY LINES PRIOR TO REMOVAL. 5.CONTRACTOR TO PROTECT AND PRESERVE IN PLACE ANY FOUND SURVEY MONUMENTS. ANY MONUMENTS DISTURBED SHALL BE RESET BY A LICENSED SURVEYOR AND THE APPROPRIATE PAPERWORK FILED WITH THE CITY OR COUNTY. 6.ALL HAZARDOUS MATERIALS ENCOUNTERED DURING SITE DEMOLITION SHALL BE REMEDIATED AND DISPOSED OF PER STATE AND EPA REQUIREMENTS. 7.CONTRACTOR SHALL CONTACT AND COORDINATE WITH ALL UTILITY AGENCIES PRIOR TO THE START OF ANY DEMOLITION OR CONSTRUCTION. 8.ANY EXISTING UTILITIES AND/OR IMPROVEMENTS THAT BECOME DAMAGED DURING CONSTRUCTION SHALL BE COMPLETELY RESTORED TO THE SATISFACTION OF THE OWNER AND AGENCY HAVING AUTHORITY, AT THE CONTRACTOR'S SOLE EXPENSE. DEMOLITION LEGEND: PROTECT EXISTING ASPHALT CONCRETE PAVEMENT TO REMAIN PROTECT EXISTING BUILDING TO REMAIN PROTECT EXISTING CONCRETE CURB TO REMAIN PROTECT EXISTING CONCRETE WHEELSTOP TO REMAIN PROTECT EXISTING TREE AND ROOTS TO REMAIN PROTECT EXISTING TRUNCATED DOMES TO REMAIN PROTECT EXISTING UTILITY TO REMAIN PROTECT EXISTING SIGN TO REMAIN PROTECT EXISTING BOLLARD TO REMAIN PROTECT EXISTING ROOF SUPPORT TO REMAIN REMOVE AND LAWFULLY DISPOSE OF ASPHALT CONCRETE PAVEMENT REMOVE AND LAWFULLY DISPOSE OF CONCRETE CURB REMOVE AND LAWFULLY DISPOSE OF CONCRETE WHEELSTOP REMOVE AND LAWFULLY DISPOSE OF LANDSCAPE SAWCUT LIMIT OF STRIPING REMOVAL REMOVE EXISTING IMPROVEMENTS AS NECESSARY TO CONSTRUCT NEW IMPROVEMENTS SHOWN ON THESE PLANS UNLESS OTHERWISE NOTED ON THE PLAN. THE REMOVAL OF IMPROVEMENTS MUST BE COORDINATED WITH ALL PLAN SHEETS. CONTRACTOR MUST ALSO COORDINATE REMOVAL OF IMPROVEMENTS WITH UTILITY AGENCIES. PROTECT ALL IMPROVEMENTS NOT DESIGNATED FOR REMOVAL. SEE NOTE 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ONLY EV CHARGING ONLY EV CHARGING NO PARKING SEBSEBSEB SEBSEBSEB SEB (BM 1 0 0 . 0 0 ) 99.77 100.11 100.00 NO PARKING NO PARKING NO PARKING RS RS RS NO PA R K I N G LP BO BO LP RS RS RS NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G LP FIP EPB PIV WV IVAIVA LP EPB IVA LP EPB CVA WV IVA CVA RS EXISTING SOLAR CANOPY EXISTING SOLAR CANOPY EXISTING SCE TRANSFORMER, P5510319 NO P A R K I N G NO P A R K I N G AL AL AL EPB EXISTING INVERTER MOUNTED ON I-BEAM (TYP) CPB 1 2 5 6 910 8 7 4 3 11 12 13 14 15161718 1920 18 ' (T Y P ) 8'-6" (TYP) 9'13'12' 20'-4" (TYP) 8' - 6 " (T Y P ) 5'-3"5'-6"15'-6"3'9'-5" 17 ' 18 ' - 4 " 3'-8"45'-10" A B D (TYP) D (TYP) E 4' F G H (TYP) J (TYP) A L L M SEE NOTE 3 (TYP) PAYMENT KIOSK 2'-9" J (TYP) T H (TYP) SEE NOTE 1 SEBSEB SEB SEB SEB SEB SEB 3'-8" 8' - 6 " C (TYP) I K 4'-6" (TYP) 4' - 6 " (T Y P ) 1'-11" K Date Signed: 06-17-2025 SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ s i 0 2 . d w g ; La y o u t 1 - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 6 p m 00002112309 AHJ PLAN CHECK 1 PLANNING COMMENTS PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 4 SITE PLAN C3.0 A C3.0 ENLARGED EQUIPMENT AND BOLLARD SPACING DETAIL SCALE: 1"=2' PROPOSED EV CHARGER EVSE-#WALL/PEDESTAL MOUNT EVSE SINGLE/DUAL EVSE STALL/CHARGE PORT # CHARGE PORT TYPE 1 PEDESTAL DUAL STANDARD 2 PEDESTAL DUAL STANDARD 3 PEDESTAL DUAL STANDARD 4 PEDESTAL DUAL STANDARD 5 PEDESTAL DUAL STANDARD 6 PEDESTAL DUAL STANDARD 7 PEDESTAL DUAL STANDARD 8 PEDESTAL DUAL STANDARD 9 PEDESTAL DUAL STANDARD 10 PEDESTAL SINGLE VAN ACCESSIBLE 11 PEDESTAL SINGLE STANDARD ACCESSIBLE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CONSTRUCTION LEGEND: 2' WIDE ELECTRICAL UTILITY TRENCH. TRENCH, BACKFILL AND RESURFACING PER DETAIL [B/E2.0] BACKFILL TRENCH IN AREAS UNDER EXISTING CURB OR CURB AND GUTTER TO REMAIN WITH 2 SACK CEMENT SLURRY MIX PER SPECIFICATIONS. SUPPORT SUSPENDED CURB AS REQUIRED DURING EXCAVATION. ALTERNATIVE OPTION TO REMOVE AND REPLACE EXISTING CURB PER DETAIL [E/C4.0] AT CONTRACTOR'S DISCRETION FURNISH AND INSTALL SERVICE EQUIPMENT BOLLARDS PER DETAIL [B/C4.0] FURNISH AND INSTALL CONCRETE WHEELSTOPS PER DETAIL [C/C4.0] FURNISH AND INSTALL FIXED ACCESSIBLE CHARGING SIGN PER DETAIL [F/C4.0] FURNISH, INSTALL AND PAINT ACCESSIBLE EV CHARGING STALLS PER DETAIL [A/C4.0] PAINT 4" WIDE WHITE PERIMETER LINE WITH 4" WIDE WHITE DIAGONAL LINES AT 3' ON CENTER REPAINT DOUBLE STRIPING REMOVED DURING TRENCHING TO MATCH EXISTING CONSTRUCT EQUIPMENT PAD PER DETAIL [D/C4.0]. EQUIPMENT PAD SHALL BE POURED FLUSH WITH ADJACENT IMPROVEMENTS FURNISH AND INSTALL EV CHARGER CONCRETE PAD PER DETAIL [D/E2.0] FURNISH AND INSTALL FIXED POST FOR EQUIPMENT MOUNTING PER DETAIL [G/C4.0] SEE ELECTRICAL CONDUIT PLAN FOR ADDITIONAL ELECTRICAL IMPROVEMENTS SEE ENLARGED EQUIPMENT AND BOLLARD SPACING DETAIL [A/C3.0] PROPOSED LITEON SC48 DUAL CHARGE PORT STYLE CHARGERS TO BE INSTALLED BY OTHERS. SEE DETAILS [A/R1.0], [B/R1.0], [D/R1.0], AND [E/R1.0] (SHOWN FOR REFERENCE ONLY) PROPOSED LITEON SC48 SINGLE CHARGE PORT STYLE CHARGERS TO BE INSTALLED BY OTHERS. SEE DETAILS [A/R1.0], [B/R1.0], [C/R1.0], AND [E/R1.0] (SHOWN FOR REFERENCE ONLY) LIMITS OF ASPHALT CONCRETE PAVEMENT IMPROVEMENTS LIMITS OF CONCRETE IMPROVEMENTS A B C D E F G H I J K L M SCALE IN FEET 0 5 10 20 SCALE: 1"=10' NOTE: 1.LANDSCAPE SCREENING FOR ELECTRICAL EQUIPMENT TO BE COMPLETED BY CUSTOMER. 1 1 ONLY EV CHARGING NO PARKING 13' (MIN)12' (MIN)9' (MIN) 18 ' ( M I N ) 6" 6"6" 2' ( M I N ) 2' ( M I N ) MAXIMUM OF 2% SURFACE SLOPE IN ALL DIRECTIONS AT ACCESSIBLE STALLS AND ACCESS AISLES PER CBC 11B-812 (TYP) PAINT 4" WIDE WHITE PERIMETER LINE WITH 4" WIDE WHITE DIAGONAL LINES AT 3' ON CENTER PAINT 4" WIDE WHITE STRIPE (TYP) PAINT 12" HIGH WHITE "EV CHARGING ONLY" WORDING PAINT 12" HIGH WHITE "NO PARKING" WORDING NOTES: 1.ACCESSIBLE EV CHARGING STALLS TO COMPLY WITH CBC 11B-812. 2.ACCESSIBLE EV CHARGING STALLS SHALL BE MARKED PER CBC 11B-812.9. 3' (T Y P ) ONLY EV CHARGING 4" 6" (MIN) CONCRETE ENCASEMENT IN STABLE SOIL 12" (MIN) CONCRETE ENCASEMENT IN SANDY OR UNSTABLE SOIL 2' - 6 " 2' - 6 " 5' 4" GALVANIZED STEEL PIPE (1/4-INCH MINIMUM WALL) FILLED WITH CONCRETE CONCRETE CAP FINISHED GRADE NOTES: 1.METERS LOCATED ON A WALL ADJACENT TO ANY PARKING AREA, OR AREA ACCESSIBLE TO VEHICULAR TRAFFIC, SHALL BE PROTECTED BY NON-REMOVABLE BARRIERS. WHEEL STOPS AND REMOVABLE BARRIERS ARE NOT ACCEPTABLE SUBSTITUTES. MAINTAIN A MINIMUM OF THREE FEET OF CLEAR AND LEVEL WORKING SPACE IN FRONT OF ALL THE SERVICE EQUIPMENT ENCLOSURES. BARRIERS MUST BE SO POSITIONED AS TO ALLOW ALL SERVICE EQUIPMENT DOORS/PANELS TO BE OPENED 90 DEGREES. 2.BARRIERS MUST BE INSTALLED IN LINE WITH EACH END OF THE SERVICE EQUIPMENT TO PREVENT VEHICLE CONTACT. THE DISTANCE BETWEEN BARRIERS SHALL NOT EXCEED 4'-6". NON-REMOVABLE BARRIER POST SECTION A-A PLAN VIEW A A 2' ( M I N ) - 3 ' ( M A X ) 3'(MIN) - 4'(MAX) 6"9"9" 2 EACH 5/8" HOLE FOR 1/2" REBAR 21 2" 5" ( M I N ) 512"( M A X ) 212"12 " 71 2"(MIN) 8"(MAX) PRECAST CONCRETE WHEELSTOP 1/2" RADIUS CORNER (TYP) 1/2"X12" REBAR ANCHOR EMBEDDED INTO PAVEMENT FINISHED SURFACE PRECAST CONCRETE WHEELSTOP FACE OF CURB OR EDGE OF SIDEWALK PARKING STALL STRIPE WIDTH VARIES (SEE PLANS) 3" (TYP) 6" 6" #4 @ 12" O.C. BOTH WAYS FINISHED SURFACE CONCRETE CURB, WHEN APPLICABLE, SEE PLAN COMPACT 12" OF NATIVE SOIL MATERIAL TO MINIMUM 95% RELATIVE COMPACTION PER ASTM D1557 6"3"CLR. 1 2" RADIUS IN PLANTER AREAS = 3" EQUIPMENT CONCRETE PAD MINIMUM CONCRETE COMPRESSIVE STRENGTH OF 2,500 PSI REQUIRED FINISHED CONCRETE OR GROUND SURFACE 2" SCH. 40 GALV. STEEL POST ADD VAN SIGN WHEN SHOWN ON PLANS, BLUE FIELD, 1/2" WHITE BORDER, AND 1" WHITE LETTERS, ALL OF REFLECTIVE SHEETING. SEE NOTE BELOW 18 GA STEEL WITH FIELD OF BLUE, 1/2" WHITE BORDER, AND WHITE ACCESSIBLE SYMBOL, ALL OF REFLECTIVE SHEETING FASTENER: 1/4" DIA. HEX. BOLT W/ LOCK WASHER 1-1/2" FROM TOP AND BOTTOM OF SIGN GALV. STEEL POST CAP CONCRETE NOTE: AS AN ALTERNATE, A SINGLE SIGN INCLUDING LEGEND AS SHOWN AT RIGHT MAY BE USED. 1" HIGH WHITE LETTERS, ALL REFLECTIVE SHEETING 12" 12 " 7" 4" 6' - 8 " ( M I N ) CL E A R 3' ( M I N ) 3" 8" 4"12" 14 " WRAP DOWEL BAR WITH PAPER AND APPLY BOND BREAKER 4" 18" SIMPSON SET-XP HIGH-STRENGTH ANCHORING ADHESIVE (ICC ESR-2508) EXISTING CONCRETE CURB PROPOSED CONCRETE CURB SECTION A-A 12 " 10" 6" VARIES, (SEE PLAN) FINISHED GRADE CONCRETE 1/2" RADIUS IN PLANTER AREAS = 2" IN TURF SOD AREAS = 1/2" IN TURF SEED AREAS = 0" #4 SMOOTH DOWEL SEE SECTION A-A. A A #4 CONT., TYP 1'-6" B22SH-120GLV UNISTRUT (TYP) PLAN VIEW AA SECTION A-A EATON B2016 PIPE CLAMP PROVIDE GALVANIZED 3-1/2" POST CAP FITTING SECURED TO POST 3-1/2" GALVANIZED STEEL POST B22SH-120GLV UNISTRUT (TYP) EXISTING SURFACE CLASS "B" CONCRETE FOOTING 1'-6" 3' - 6 " 3" (C L R ) Date Signed: 06-17-2025 SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ d t 0 1 . d w g ; La y o u t 1 - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 6 p m 00002112309PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 5 DETAILS C4.0 A C4.0 ACCESSBILE EV CHARGING STALLS NOT TO SCALE B C4.0 SERVICE EQUIPMENT BOLLARD NOT TO SCALE C C4.0 CONCRETE WHEELSTOP NOT TO SCALE D C4.0 EQUIPMENT PAD NOT TO SCALE F C4.0 ACCESSBILE CHARGING SIGN NOT TO SCALE E C4.0 CONCRETE CURB NOT TO SCALE G C4.0 FIXED POST FOR EQUIPMENT MOUNTING NOT TO SCALE 8 1/2" 8 1 / 2 " CONDUIT ENTRY 4' (M A X ) 2' 2' 2' 7" 7" 3" SECTION A-A AA PLAN VIEW 6' - 8 ' (M A X ) 5" x 5" ALUMINUM PEDESTAL CHARGER PEDESTAL 10 " 2' 1/2" x 4-1/4" 304 STAINLESS STEEL WEDGE ANCHOR PER PEDESTAL INSTALLATION 5' - 6 " 3' - 5 " SECTION A-A 8 1/2" 8 1 / 2 " CONDUIT ENTRY 2' 2' 7" 7" 3" AA PLAN VIEW CHARGER PEDESTAL 5" x 5" ALUMINUM PEDESTAL 6' - 8 ' (M A X ) 2' 10 " 1/2" x 4-1/4" 304 STAINLESS STEEL WEDGE ANCHOR PER PEDESTAL INSTALLATION 10 REFERENCE DRAWINGS R1.0 A R1.0 LITEON SPECIFICATIONS AND DIMENSIONS NOT TO SCALE C R1.0 LITEON SINGLE PORT PEDESTAL INSTALLATION FOR ADA NOT TO SCALE D R1.0 LITEON DUAL PORT PEDESTAL INSTALLATION NOT TO SCALE B R1.0 LITEON AMPERE SETTINGS NOT TO SCALE E R1.0 POWERFLEX PEDESTAL DIMENSIONS NOT TO SCALE F R1.0 POWERFLEX PEDESTAL SPECIFICATIONS NOT TO SCALE NOTES: 1.REFER TO INSTALLATION MANUAL FOR ADDITIONAL INFORMATION. 2.TO BE INSTALLED BY OTHERS UNDER SEPARATE PERMIT. 3.SHOWN FOR REFERENCE ONLY. SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ d t 0 4 . d w g ; La y o u t 1 - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 6 p m 00002112309PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 11 REFERENCE DRAWINGS R1.1 C R1.1 NEXUS CONTROLLER SPECIFICATION NOT TO SCALE A R1.1 POWERFLEX LOAD MANAGEMENT CONTROLLER SPECIFICATIONS NOT TO SCALE B R1.1 POWERFLEX KIOSK SPECIFICATIONS (OLEA KIOSK) NOT TO SCALE NOTES: 1.REFER TO INSTALLATION MANUAL FOR ADDITIONAL INFORMATION. 2.TO BE INSTALLED BY OTHERS UNDER SEPARATE PERMIT. 3.SHOWN FOR REFERENCE ONLY. SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ d t 0 4 . d w g ; La y o u t 1 ( 2 ) - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 6 p m 00002112309PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 D R1.1 POWERFLEX NEXUS CORE AND WIFI ACCESS POINT SPECIFICATIONS NOT TO SCALE SHEET NO.TITLE SHEET INDEX TITLE SHEETT1.0 TOPOGRAPHIC SURVEY & DEMOLITION PLANC2.0 SITE PLANC3.0 DETAILSC4.0 ELECTRICAL CONDUIT PLANE1.0 ELECTRICAL SCHEDULE AND CIRCUITSE3.0 REFERENCE DRAWINGSR1.0 CONDUIT SECTIONS AND DETAILSE2.0 1 TITLE SHEET OVERALL SITE PLANC1.0 LOCATION MAP NOT TO SCALE TOTAL NUMBER OF SHEETS = 12 TITLE 24 DOCUMENTSR2.0 T1.0 GENERAL CONTRACT NOTES: 1.CONTRACTOR SHALL PROVIDE ALL MATERIALS SUCH AS TOOLS, EQUIPMENT, LABOR, AND INCIDENTALS REQUIRED INCLUDING THE CONSTRUCTION OF ALL PROPOSED IMPROVEMENTS SHOWN ON THE PLANS AND AS SPECIFIED BY THE GOVERNING STANDARDS AND/OR THE CIVIL AND ELECTRICAL ENGINEERS. 2.CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION OF THE PROPOSED IMPROVEMENTS. 3.IF DAMAGED DURING CONSTRUCTION, THE CONTRACTOR SHALL REPLACE IN KIND ALL EXISTING STRUCTURES, WALKWAYS, CURB & GUTTER, LANDSCAPING, AND/OR OTHER IMPROVEMENTS TO AN EXISTING OR BETTER CONDITION. 4.CONTRACTOR SHALL REPLACE ALL EXISTING STRIPING, SIGNAGE AND MARKINGS DAMAGED DUE TO PROJECT CONSTRUCTION ACTIVITIES. 5.ALL WORK SHALL BE CONFINED WITHIN THE EASEMENTS AND/OR CONSTRUCTION LIMITS AS SHOWN ON THE PLANS. 6.APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY WORK TO BE PERFORMED UNTIL A PERMIT OR NOTICE TO PROCEED HAS BEEN ISSUED. 7.BEFORE COMMENCING WORK, THE CONTRACTOR SHALL NOTIFY ALL UTILITY AUTHORITIES OR UTILITY COMPANIES HAVING POSSIBLE INTEREST IN THE WORK OF THE CONTRACTOR'S INTENTION TO EXCAVATE PROXIMATE TO EXISTING FACILITIES AND THE CONTRACTOR SHALL VERIFY THE LOCATION OF ANY UTILITIES IN THE WORK AREA. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (U.S.A.) TWO (2) DAYS PRIOR TO BEGINNING ANY EXCAVATION. 8.THE CONTRACTOR SHALL OBTAIN WRITTEN AUTHORIZATION FROM ANY PROPERTY OWNER GIVING HIM PERMISSION TO ENTER HIS PROPERTY FOR THE PURPOSE OF CONSTRUCTING THE IMPROVEMENTS DELINEATED ON THE PLANS AND TRANSITION THERETO. 9.ALL BILL OF MATERIALS AND/OR EQUIPMENT SHALL BE PROVIDED AS SPECIFIED WITHIN THIS SET OR APPROVED EQUAL. ALL BILL OF MATERIALS AND/OR EQUIPMENT SHALL MATCH THE SAME QUALITY AND CAPACITY AS INDICATED HEREIN. 10.CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IDENTIFIED BY THE PROFESSIONAL ENGINEERING SEAL AND SIGNATURE ON THESE PLANS, OF ANY SITE CONDITION(S) AND/OR DESIGN INFORMATION THAT PREVENTS THE CONTRACTOR FROM COMPLYING WITH THE LAWS, REGULATIONS AND/OR BUILDING CODES. PROJECT LOCATION: PROJECT IS LOCATED AT: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 APN: 414-262-08 DESIGN CRITERIA: CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 NATIONAL ELECTRICAL CODE (NEC) 2020 SCOPE OF EV IMPROVEMENT WORK: 1.SITE AND ELECTRICAL INFRASTRUCTURE IMPROVEMENTS FOR INSTALLATION OF EV CHARGERS. 2.IMPACTED EXISTING PARKING = 21 TOTAL SPACES; 21 STANDARD SPACES 3.EV CHARGER INSTALLATION PERFORMED BY OTHERS UNDER SEPARATE PERMIT. 4.WORK DONE BY THE TRANSMISSION AND DISTRIBUTION CONSULTANT (T&D) IS SHOWN FOR REFERENCE ONLY. PROPOSED EV CHARGER TABULATION EV CHARGER NO. OF EVSES NO. OF PORTS SINGLE (LEVEL 2)2 2 DUAL (LEVEL 2)9 18 TOTAL TOTAL EVSES = 11 TOTAL PORTS = 20 CBC 11B-228.3.2.1 REQUIRES EV CHARGING ACCESSIBLE STALLS TO BE INSTALLED. 5 TO 25 PORTS = 1 VAN ADA, 1 STANDARD ADA (SEE PLANS FOR LOCATION) LIST OF CONSULTANTS: CIVIL:ELECTRICAL: DAVID MOWRY BLAIR CHURCH & FLYNN 451 CLOVIS AVE. STE 200 CLOVIS, CA 93612 (559) 326-1400 BRIAN DUFFY BLAIR CHURCH & FLYNN 451 CLOVIS AVE. STE 200 CLOVIS, CA 93612 (559) 326-1400 SCE PROJECT MANAGER: CHRIS KANOWSKY CHRIS.KANOWSKY@SCE.COM (310) 803-4956 OWNER/REPRESENTATIVE INFORMATION: KAISER FOUNDATION HEALTH PLAN, INC 3401 S HARBOR BLVD., SANTA ANA, CA 92704 TELEPHONE: (714) 644-5431 CONTACT: ANDY DUMAINE BENCHMARK: BENCHMARK: CNPT #11, CH "X" ASSUMED ELEV: 100.00 FT ELEVATIONS ARE ASSUMED AND WERE OBTAINED USING LEICA EQUIPMENT AND SOFTWARE. UTILITY NOTE: UTILITY INFORMATION SHOWN HEREON IS BASED ON RECORD INFORMATION SUPPLIED TO THE ENGINEER BY UTILITY COMPANIES, PUBLIC AGENCIES AND THE PROPERTY OWNER, TOGETHER WITH EVIDENCE GATHERED FROM GPR LOCATING METHODS. THE ENGINEER CAN MAKE NO GUARANTEE AS TO THE ACCURACY OR COMPLETENESS OF THE UNDERGROUND UTILITY FACILITIES SHOWN. PRIOR TO ANY SITE EXCAVATIONS, THE CONTRACTOR SHALL CONTACT THE OWNER AND UNDERGROUND SERVICE ALERT (U.S.A.) AND REQUEST THAT THEY IDENTIFY THE LOCATION OF ALL UNDERGROUND UTILITIES AT THE SITE. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. Date Signed: 06-17-2025 SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ t i 0 1 . d w g ; La y o u t 1 - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 6 p m 00002112309 AHJ PLAN CHECK 1 Date Signed: 06-17-2025 PLANNING COMMENTS PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 W MACARTHUR BLVD W LAKE CENTER DR HA R B O R B L V D PROJECT LOCATION REFERENCE DRAWINGSR1.1 CONDUIT SECTIONS AND DETAILSE2.1 12 TITLE 24 DOCUMENTS R2.0 SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ d t 0 5 . d w g ; La y o u t 1 - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 7 p m 00002112309 Date Signed: 06-17-2025 PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 Brian Duffy Blair, Church & Flynn Consulting Engineers 451 Clovis Ave., Suite 200 Clovis, CA 93612 E22220 (559) 326-1400 06/17/2025 451 Clovis Ave., Suite 200 Clovis, CA 93612 06/17/2025 (559) 326-1400 3401 S HARBOR BLVD., SANTA ANA, CA 92704 NEW SERVICE CT METER NEW SERVICE CT METER 3401 S HARBOR BLVD., SANTA ANA, CA 92704 BRIAN DUFFY ONLY EV CHARGING ONLY EV CHARGING NO PARKING SEBSEBSEB SEBSEBSEB SEB (BM 1 0 0 . 0 0 ) 99.77 100.11 100.00 NO PARKING NO PARKING NO PARKING RS RS RS NO PA R K I N G LP BO BO LP RS RS RS NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G LP FIP EPB PIV WV IVAIVA LP EPB IVA LP EPB CVA WV IVA CVA RS EXISTING SOLAR CANOPY EXISTING SOLAR CANOPY EXISTING SCE TRANSFORMER, P5510319 NO P A R K I N G NO P A R K I N G AL AL ALET EPB EXISTING INVERTER MOUNTED ON I-BEAM (TYP) CPB W W W E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD E E E UNK UNK UN K UN K UN K UNK UN K C C C C C C C C C C C C C C C C C C E E E E E E E E E E E IR R IR R IR R IR R IRR IRR IRR IRR IRR IRR IRR IRR IR R IR R IR R IR R IR R IRR IR R UNK UNK UNK UNK UNK UNK E E E E E E E E E E SD SD W W W W W E E E E E E E E E C C C C C C C C 1 2 5 6 910 8 7 4 3 11 12 13 14 15161718 1920 EVSE-1EVSE-2 EVSE-3 EVSE-4 EVSE-5 EVSE-6EVSE-7 EVSE-8 EVSE-9 EVSE-10 EVSE-11 (K1-K5, C2) (K1-K4, C1-C2) (K1,K2, C2) (K5) T SCE TRANSFORMER, 12KV, 150KVA, 208Y/120V, 3Ø, 4W (K6-K12, C1) (K8-K12, C1) (K9,K11, K12, C1) (K7-K12, C1) (K9,K11)(K12, C1) (P1,P2) (K13, C1-C2) A B C C E H (TYP) (K10) (TYP) (TYP) F D (TYP) (K1, C2) G SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ e l 0 1 . d w g ; La y o u t 1 - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 6 p m 00002112309 Date Signed: 06-17-2025 PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 6 ELECTRICAL CONDUIT PLAN E1.0 SCALE IN FEET 0 5 10 20 SCALE: 1"=10' ELECTRICAL LEGEND: FURNISH AND INSTALL SERVICE CT METER AND MAIN SWITCHBOARD PER DETAILS [A/E2.0], [A/E3.0], AND [C/E3.0] FURNISH AND INSTALL POWERFLEX NEXUS CORE TERMINAL BOX PER DETAILS [C/E2.0] AND [E/E2.0] SEE DETAIL [B/E2.0] FOR THE FURNISHING AND INSTALLATION OF BELOW GRADE PVC CONDUIT. SEE CONDUIT SCHEDULE FOR COUNT AND CONDUIT SIZE FURNISH AND INSTALL TEMPORARY TERMINAL BLOCK AND APPURTENANCES FOR EV CHARGER PEDESTALS. CONSTRUCT PER DETAIL [B/E2.1] FURNISH AND INSTALL TEMPORARY TERMINAL BOX AND APPURTENANCES FOR PAYMENT KIOSK. CONSTRUCT PER DETAILS [C/E2.0] AND [A/E2.1] FURNISH AND INSTALL TEMPORARY TERMINAL BLOCK AND APPURTENANCES FOR EV CHARGER PEDESTALS WITH ADDED WIRELESS ACCESS POINT. CONSTRUCT PER DETAIL [B/E2.1] FURNISH AND INSTALL (JENSEN PRECAST) 11"X17"X12"D CLOSED BOTTOM FLAT WALL PULL BOX WITH TRAFFIC RATED SECURITY BOLTED MARKED "ELECTRIC" COVER. GROUT SEAL CONDUIT PENETRATIONS AND SEAL CONDUITS WITH DUCT SEAL OR EQUAL TO PREVENT WATER ENTRY. SEE DETAIL [E/E2.0] GROUND ROD 12" (MIN) BELOW SURFACE PROPOSED SERVICE CT METER AND MAIN SWITCHBOARD POWERFLEX NEXUS CORE. TO BE INSTALLED BY OTHERS. (SHOWN FOR REFERENCE ONLY) PAYMENT KIOSK. TO BE INSTALLED BY OTHERS. (SHOWN FOR REFERENCE ONLY) GROUND ACCESS WELL AND 5/8" X 8' COPPER CLAD GROUND ROD SOUTHERN CALIFORNIA EDISON ELECTRICAL TRANSFORMER, BY T&D (SHOWN FOR REFERENCE ONLY) PROPOSED LITEON SC48 DUAL CHARGE PORT STYLE CHARGERS TO BE INSTALLED BY OTHERS. SEE DETAILS [A/R1.0], [B/R1.0], [D/R1.0], AND [E/R1.0] (SHOWN FOR REFERENCE ONLY) PROPOSED LITEON SC48 SINGLE CHARGE PORT STYLE CHARGERS TO BE INSTALLED BY OTHERS. SEE DETAILS [A/R1.0], [B/R1.0], [C/R1.0], AND [E/R1.0] (SHOWN FOR REFERENCE ONLY) BURIED BARE COPPER GROUND WIRE ELECTRICAL CONDUIT; SIZE AND COUNT AS NOTED SOUTHERN CALIFORNIA EDISON ELECTRICAL SERVICE SUPPLY TO METER, BY T&D (SHOWN FOR REFERENCE ONLY) A B C D E F G H T CONDUIT SCHEDULE CONDUIT NUMBER FROM TO CONDUCTORS ALL 90°C THWN-2 OR SIMILAR UNLESS NOTED OTHERWISE CONDUCTOR LENGTH (FT)VOLTAGE DROP CONDUIT SIZE/TYPE COMMENTS P1 PROPOSED SCE TRANSFORMER SERVICE CT METER AND MAIN SWITCHBOARD PER SCE --4" PVC P2 PROPOSED SCE TRANSFORMER SERVICE CT METER AND MAIN SWITCHBOARD PER SCE --4" PVC K1 SERVICE CT METER AND MAIN SWITCHBOARD EVSE-1 (CHARGE PORTS 1 & 2) SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED EVSE-1, CHARGE PORTS 1 & 2 (L1,L2,GND)92 2.2%1" PVC K2 SERVICE CT METER AND MAIN SWITCHBOARD EVSE-2 (CHARGE PORTS 3 & 4) SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED EVSE-2, CHARGE PORTS 3 & 4 (L1,L2,GND)91 2.2%1" PVC K3 SERVICE CT METER AND MAIN SWITCHBOARD EVSE-3 (CHARGE PORTS 5 & 6) SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED EVSE-3, CHARGE PORTS 5 & 6 (L1,L2,GND)75 1.8%1" PVC K4 SERVICE CT METER AND MAIN SWITCHBOARD EVSE-4 (CHARGE PORTS 7 & 8) SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED EVSE-4, CHARGE PORTS 7 & 8 (L1,L2,GND)74 1.8%1" PVC K5 SERVICE CT METER AND MAIN SWITCHBOARD EVSE-5 (CHARGE PORTS 9 & 10) SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED EVSE-5, CHARGE PORTS 9 & 10 (L1,L2,GND)80 1.9%1" PVC K6 SERVICE CT METER AND MAIN SWITCHBOARD EVSE-6 (CHARGE PORTS 11 & 12) SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED EVSE-6, CHARGE PORTS 11 & 12 (L1,L2,GND)34 0.8%1" PVC K7 SERVICE CT METER AND MAIN SWITCHBOARD EVSE-7 (CHARGE PORTS 13 & 14) SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED EVSE-7, CHARGE PORTS 13 & 14 (L1,L2,GND)38 0.9%1" PVC K8 SERVICE CT METER AND MAIN SWITCHBOARD EVSE-8 (CHARGE PORTS 15 & 16) SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED EVSE-8, CHARGE PORTS 15 & 16 (L1,L2,GND)52 1.3%1" PVC K9 SERVICE CT METER AND MAIN SWITCHBOARD EVSE-9 (CHARGE PORTS 17 & 18) SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED EVSE-9, CHARGE PORTS 17 & 18 (L1,L2,GND)66 1.6%1" PVC K10 SERVICE CT METER AND MAIN SWITCHBOARD EVSE-10 (CHARGE PORT 19) SOUTHWIRE (2) #8, (1) #8 GRN GROUND, TAGGED EVSE-10, CHARGE PORT 19 (L1,L2,GND)61 1.5%1" PVC K11 SERVICE CT METER AND MAIN SWITCHBOARD EVSE-11 (CHARGE PORT 20) SOUTHWIRE (2) #8, (1) #8 GRN GROUND, TAGGED EVSE-11, CHARGE PORT 20 (L1,L2,GND)69 1.7%1" PVC K12 SERVICE CT METER AND MAIN SWITCHBOARD PAYMENT KIOSK SOUTHWIRE (2) #12, (1) #12 GRN GROUND, TAGGED (L1,L2,N,GND)66 0.9%1" PVC K13 SERVICE CT METER AND MAIN SWITCHBOARD POWERFLEX NEXUS CORE SOUTHWIRE (2) #12, (1) #12 GRN GROUND, TAGGED (PFLMC,L1,N,GND)25 0.3%1" PVC / RMC C1 POWERFLEX NEXUS CORE PAYMENT KIOSK SHIELDED CAT6 CABLE 71 -1" PVC COMMUNICATION TO POWERFLEX SYSTEM C2 POWERFLEX NEXUS CORE POWERFLEX WIFI ACCESS POINT SHIELDED CAT6 CABLE 78 -1" PVC A E1.0 CONDUIT SCHEDULE ELECTRICAL NOTES: 1.ELECTRICAL UTILITY LINE TO BE PROTECTED IN PLACE WHEN POSSIBLE. IF EXISTING LINES INTRODUCE EXCESSIVE CONSTRAINTS DURING THE INSTALLATION OF THE ELECTRICAL EQUIPMENT, REMOVE AND RELOCATE EXISTING LINES AS NEEDED, USING THE PROPOSED UTILITY TRENCH. IF THE ELECTRICAL LINE CANNOT BE SALVAGED THE CONTRACTOR MUST LAWFULLY DISPOSE OF THE ELECTRICAL LINE AND REPLACE WITH LIKE-IN-KIND. 2.ALL ELECTRICAL POWER IN CLOSE PROXIMITY TO THE INSTALLATION OF THE ELECTRICAL EQUIPMENT MUST BE POWERED OFF PRIOR TO THE START OF CONSTRUCTION, TO PREVENT ANY ELECTRICAL INJURIES. 3.HAND DIG ALL UTILITIES IN CLOSE PROXIMITY TO THE INSTALLATION OF THE ELECTRICAL EQUIPMENT TO AVOID DAMAGING ANY UTILITY LINE. 4.SEE SINGLE LINE DIAGRAM ON SHEET E3.0. 5.SEE CONDUIT SCHEDULE ON SHEET FOR WIRE SIZE, CONDUIT FILL AND WIRE TAGS. 6.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION. 7.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. 8.MINIMUM CONDUIT BURIAL DEPTH SHALL BE 24". 9.PER CEC/NEC 110.26 "ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT." 10.CONDUIT BODIES SHALL BE USED AS NEEDED TO MAINTAIN LESS THAN 360° OF CONDUIT BENDS BETWEEN PULL POINTS. 11.CONDUIT ROUTING AND DETAILS SHOWN IN PLANS ARE DIAGRAMMATIC ONLY. FINAL CONDUIT INSTALLATION MAYBE FIELD FIT AS NEEDED. 12.FINAL LOCATION OF POWERFLEX WIRELESS ACCESS POINT MAY BE FIELD FIT, AND ADDITIONAL WIRELESS ACCESS POINTS MAY BE ADDED AS NEEDED, TO ENSURE CONNECTIVITY AND CONTINUITY OF CHARGER NETWORK. SEE DETAIL [D/R1.1] 8' - 6 " 3' 2' - 6 " 3' 6"2'-8"6" 3'-8" 6"2'-8"6" 3'-8" 5' - 4 " 3'2'-6"3' 8'-6" 5' - 4 " 6"6" 6' ( M I N . ) (K1-K5)(K6-K12)(K1-K5) (P1,P2) (P1,P2) (K1-K5)(K6-K12) SECTION A-APLAN VIEW SECTION B-B (K13) (K13)(K13) 15 1 2 3 4 11 8 9 10 12 13 15(TYP) (TYP) 5 5 5 7 16 176 18 19 (TYP)6 7 16 17 (TYP) 6 7 15 6 7 18 19 14 7 18 196 12 " ( M I N ) 6" (M I N ) 11 2" VARIES (SEE PLAN) 7-INCH OF 3/4-INCH MEDIUM, TYPE B ASPHALT CONCRETE SAWCUT T-SECTION AND MATCH ADJACENT ASPHALT CONCRETE * NOTES: 1.PER NEC 300.5 (D)(3), UNDERGROUND SERVICE CONDUCTORS THAT ARE NOT ENCASED IN CONCRETE AND THAT ARE BURIED 450MM (18") OR MORE BELOW GRADE SHALL HAVE THEIR LOCATION IDENTIFIED BY A WARNING RIBBON THAT IS PLACED IN THE TRENCH AT LEAST 300MM (12") ABOVE THE UNDERGROUND INSTALLATION. 2.1.5 SACK SLURRY, RED DYE CAN BE USED IN LIEU OF COMPACTING NATIVE SOIL UNDER CONCRETE AND ASPHALT AREAS. METALLIC WARNING TAPE 95% MINIMUM RELATIVE COMPACTED NATIVE BACKFILL UNDER CONCRETE AND ASPHALT AREAS, PER ASTM D1557. 90% MINIMUM RELATIVE COMPACTED NATIVE BACKFILL UNDER LANDSCAPE AREAS, PER ASTM D1557. SEE NOTE 2. ELECTRICAL CONDUIT, SEE ELECTRICAL PLANS FOR SIZE AND COUNT (TYP) 24" (MAX) DEPTH, AT LEAST 12" ABOVE CONDUIT EXISTING ELECTRICAL CONDUIT WHERE APPLICABLE EXISTING ELECTRICAL CONDUIT CROSSING WHERE APPLICABLE MINIMUM CONDUIT BURIAL DEPTH SHALL BE 24". TRENCH RESURFACING IN CONCRETE AREA TRENCH RESURFACING IN ASPHALT AREA 95% MINIMUM RELATIVE COMPACTED NATIVE MATERIAL IN TOP 2' OF TRENCH. SEE NOTE 2. SAWCUT AND MATCH ADJACENT CONCRETE 6" (MIN)CALTRANS CLASS 3 CONCRETE EXISTING CONCRETE 6"EXISTING ASPHALT CONCRETE PAVEMENT EXISTING CURB 6" L1 N G G RMC FOR POWERFLEX NEXUS CORE RMC FOR POWERFLEX NEXUS CORE RMC FOR POWERFLEX NEXUS CORE * * * RMC FOR POWERFLEX NEXUS CORE * NOTES: 1.POWERFLEX NEXUS CORE AND PAYMENT KIOSK TO BE INSTALLED BY OTHERS. 2.WHEN 2 OR MORE CONDUITS ENTER THE TERMINAL BOX, BOND ALL HUBS TOGETHER AND INSURE TO GROUND ONE. 3.SEE CONDUIT SCHEDULE ON SHEET E1.0 FOR CONDUIT SIZE. * BONDING JUMPER #12 LOAD MANAGEMENT CONTROLLER WIRE #12 #12 (TYP) 4 31(TYP) 6 5 2 (TYP) BILL OF MATERIALS REFERENCE NUMBER ITEM QUANTITY 1 ABB RGW25-M5 OR M-6 RING LUG TERMINAL BLOCKS 4 EA 2 ABB BAZH1 END STOP, ISNK900102R0000 2 EA 3 ABB CS-RGW-L CIRCUIT SEPARATOR, 1SNA519201R0000 1 EA 4 35 MM DIN RAIL 1 EA 5 HOFFMAN 12"X12"X6" SCREW COVER GALVANIZED JUNCTION BOX A6R66GV, NEMA 3R 1 EA 6 EATON STRAIGHT LIQUID TIGHT CONDUIT FITTING 1" LT100GSA, BY OTHERS DURING PHASE 2 1 EA PLAN VIEW 6' (M A X ) 1'-6" 3" (C L R ) CORE TERMINAL JUNCTION BOX SEE [C/E2.0] POWERFLEX NEXUS CORE TO BE INSTALLED BY OTHERS (SHOWN FOR REFERENCE ONLY) AA 1'-6" (C1) 4' - 4 " 1' - 8 " 3' - 6 " (K13) BILL OF MATERIALS [E/E2.0] REFERENCE NUMBER ITEM QUANTITY 1 EATON B-LINE, B22SH-120GLV AR 2 B-LINE, HEX HEAD CAP SCREW, 3/8" X 1-1/4" 16 HHCS ZINC AR 3 B-LINE, SPRING NUT, N228, 3/8"-16 AR 4 1" RMC CONDUIT, CALCONDUIT OR EQUAL AR 5 CANTEX CATALOGUE NO. 5140050, 1" PVC FEMALE ADAPTER OR EQUAL 2 EA 6 MYERS HUB CATALOGUE NO. STG 8, 1" GROUND HUB, NEMA 3R OR EQUAL 2 EA 7 #12 CU CONDUCTOR THWN-2 AR 8 #12 CU CONDUCTOR GRN INSULATION THWN-2 AR 9 SHIELDED CAT6 CABLE AR B22SH-120GLV UNISTRUT (TYP) EATON B2016 PIPE CLAMP 2 31 6(TYP) 5 (TYP) 4 7 8 4 9 (C2) BILL OF MATERIALS [A/E2.0] REFERENCE NUMBER ITEM QUANTITY 1 Z POWER, CT METERED SWITCHBOARD, NEMA TYPE 3R, 208Y/120V, 3Ø, 4W, 600 AMP, 42 KAIC FULLY RATED 1 UNIT 2 MAIN BREAKER, 240 VOLT, 600 AMP TRIP, 42 KAIC (MINIMUM) AT 240V, 3 POLE 1 EA 3 BRANCH BREAKER, 240 VOLT, 40 AMP, 42 KAIC (MINIMUM) AT 240V, 2 POLE 20 EA 4 BRANCH BREAKER, 120 VOLT, 20 AMP, 42 KAIC (MINIMUM) AT 120V, 1 POLE 2 EA 5 1" PVC BELL END OR EQUAL 14 EA 6 1" SCH. 40 PVC, 18" RADIUS OR EQUAL 14 EA 7 1" SCH. 40 PVC AR 8 HILTI KWIK BOLT 5/8'' WITH 4'' EMBEDMENT AR 9 GALVANIZED NUT, 5/8"AR 10 GALVANIZED LOCK WASHER, 5/8"AR 11 PADLOCK AR 12 5/8" X 8' ERICO COPPER CLAD GROUND ROD, INSTALLED VERTICALLY WITH WELL COVER 2 EA 13 FIGURE "8" GROUND ROD COMPRESSION FITTING, #2 OR #2/0 TO 5/8" ROD 2 EA 14 GROUND BUS BAR KIT 1 EA 15 #2 BARE COPPER WIRE AR 16 #8 CU CONDUCTOR THWN-2 AR 17 #8 CU CONDUCTOR GRN INSULATION THWN-2 AR 18 #12 CU CONDUCTOR THWN-2 AR 19 #12 CU CONDUCTOR GRN INSULATION THWN-2 AR 1/2" THICK STEEL DIAMOND PLATE COVER FOR H-20 TRAFFIC LOADING, MARKED "ELECTRIC" *VARIES (SEE CONDUIT PLAN AND BILL OF MATERIALS FOR DETAILS) 1" DIA. PICK HOLE (2) 5/8" DIA. BOLTDOWN HOLES WITH BOLTS 5/8" x 8' COPPER GROUND ROD. IF BOX IS COMPOSITE WITH COMPOSITE LID, GROUND ROD IS NOT NEEDED COMPACT 12" OF NATIVE SOIL MATERIAL TO MINIMUM 95% RELATIVE COMPACTION PER ASTM D1557 PULL BOX LID TO BE SECURELY BONDED TO GROUND ROD IF METALLIC *V A R I E S 6" (M I N ) CRUSHED ROCK ROOFING PAPER LAYER PULLBOX TO BE OF COMPOSITE TYPE VARIES (WIDTH TO MATCH PULLBOX) NOTES: 1.SEE SHEET E1.0 FOR PULLBOX SIZE AND LOCATION. 2.CONTRACTOR TO CUT HOLES REQUIRED FOR CONDUIT AND GROUND ROD. * ** ** ASPHALT CONCRETE PAVEMENT AREAS CONCRETE AREAS FLUSHFLUSH SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ d t 0 2 . d w g ; La y o u t 1 - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 6 p m 00002112309 Date Signed: 06-17-2025 PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 7CONDUIT SECTIONS AND DETAILS E2.0 A E2.0 SERVICE CT METER AND MAIN SWITCHBOARD NOT TO SCALE B E2.0 TYPICAL ELECTRICAL UTILITY TRENCH NOT TO SCALE C E2.0 POWERFLEX NEXUS CORE TERMINAL BOX & KIOSK TERMINAL BOX NOT TO SCALE D E2.0 POWERFLEX NEXUS CORE TERMINAL BOX MOUNTING DETAIL NOT TO SCALE NOTES: 1.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION. 2.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. 3.MINIMUM CONDUIT BURIAL DEPTH SHALL BE 24". 4.PER CEC/NEC 110.26 "ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT." 5.ALL ABOVE GRADE CONDUIT CONSTRUCTION SHALL FOLLOW CEC/NEC 342, 344, 350, OR 358 FOR IMC, RMC, LFMC OR EMT CONSTRUCTION. 6.ALL ELECTRICAL EQUIPMENT SHALL BE LISTED FOR TERMINATION OF ELECTRICAL CONDUCTORS RATED 75°C OR HIGHER. 7.CONDUIT ROUTING AND DETAILS SHOWN IN PLANS ARE DIAGRAMMATIC ONLY. FINAL CONDUIT INSTALLATION MAYBE FIELD FIT AS NEEDED. E E2.0 TRAFFIC RATED OPEN BOTTOM PULLBOX NOT TO SCALE CONDUIT K12 ELECTRICAL CONDUIT BEYOND. SEE ELECTRICAL PLANS 6' ( M I N ) CONCRETE PAD 1 2 3 4 1' (T Y P ) 7SEE NOTE 2 (TYP) 5 6 1' - 6 " ( M I N ) 24 " ( M I N ) AA IN PLANTER AREAS = 3" FINISHED SURFACE CONDUIT C1 NOTES: 1.TERMINAL BLOCK AND TEMPORARY SUPPORT WILL BE REMOVED ONCE CHARGERS ARE INSTALLED. 2.SECURELY FASTEN PVC CONDUIT TO CONDUIT SUPPORT WITH 1/4" WIDE UV STABILIZED NYLON CABLE TIES. PROVIDE 1 TIE EVERY 12". FIELD FIT CONDUIT ATTACHMENT AND CONFIGURATION AS NEEDED TO FIT WITHIN THE 3.2'' X 3.2'' OPENING AS SHOWN IN SECTION A-A 3.PARTS INCLUDED IN THE BILL OF MATERIALS ARE FOR 1 TEMPORARY TERMINAL BLOCK ONLY. SEE ELECTRICAL CONDUIT PLAN FOR LOCATION AND COUNT. BILL OF MATERIALS (1 UNIT) REFERENCE NUMBER ITEM QUANTITY 1 VYNCKIER VM554 ENCLOSURE 1 EA 2 VYNCKIER BACKING PLATE VMBP55A 1 EA 3 TERMINAL BLOCK BUSSMANN 14004-6, 90A, #4-14 AWG CU, 600 VAC 1 EA 4 EATON B-LINE B22SH120 HDG, 12GA, 10' LENGTHS 1 EA 5 B-LINE 1/4 X 1.25" 20 HHCS ZINC 2 EA 6 B-LINE SPRING NUT, N224, 1/4 - 20 2 EA 7 UV STABILIZED NYLON CABLE TIES (1/4" WIDTH)5 EA 10 " 2' 4 2' 2' 1' 11" C1 RISER PAYMENT KIOSK SECTION A-A (K12) 1'-1" BASEPLATE TO BE INSTALLED BY OTHERS SEE DETAIL [B/R1.1] 1" FINISHED SURFACE PVC ELECTRICAL CONDUIT RISER ELECTRICAL CONDUIT BEYOND. SEE ELECTRICAL PLANS 6' ( M I N ) CONCRETE PAD 1 2 3 4 NOTES: 1.TERMINAL BLOCK AND TEMPORARY SUPPORT WILL BE REMOVED ONCE CHARGERS ARE INSTALLED. 2.SECURELY FASTEN PVC CONDUIT TO CONDUIT SUPPORT WITH 1/4" WIDE UV STABILIZED NYLON CABLE TIES. PROVIDE 1 TIE EVERY 12". 3.PARTS INCLUDED IN THE BILL OF MATERIALS ARE FOR 1 TEMPORARY TERMINAL BLOCK ONLY. SEE ELECTRICAL CONDUIT PLAN FOR LOCATION AND COUNT. 1' (T Y P ) 7SEE NOTE 2 (TYP) 5 6 1' - 6 " ( M I N ) 24 " ( M I N ) 10 " 2' AA IN PLANTER AREAS = 3" CONCRETE CURB, WHEN APPLICABLE, SEE PLAN BILL OF MATERIALS (1 UNIT) REFERENCE NUMBER ITEM QUANTITY 1 VYNCKIER VM554 ENCLOSURE 1 EA 2 VYNCKIER BACKING PLATE VMBP55A 1 EA 3 TERMINAL BLOCK BUSSMANN 14004-6, 90A, #4-14 AWG CU, 600 VAC 1 EA 4 EATON B-LINE B22SH120 HDG, 12GA, 10' LENGTHS 1 EA 5 B-LINE 1/4 X 1.25" 20 HHCS ZINC 2 EA 6 B-LINE SPRING NUT, N224, 1/4 - 20 2 EA 7 UV STABILIZED NYLON CABLE TIES (1/4" WIDTH)5 EA FINISHED SURFACE (3) #4 EACH WAY CENTERED IN SLAB 4 2' 2' 1' SECTION A-A EV CHARGER 1' PVC ELECTRICAL CONDUIT RISER CONDUIT K1 ELECTRICAL CONDUIT BEYOND. SEE ELECTRICAL PLANS 6' ( M I N ) CONCRETE PAD 1 2 3 4 1' (T Y P ) 7SEE NOTE 2 (TYP) 5 6 1' - 6 " ( M I N ) 24 " ( M I N ) AA IN PLANTER AREAS = 3" CONCRETE CURB, WHEN APPLICABLE, SEE PLAN FINISHED SURFACE CONDUIT C2 NOTES: 1.TERMINAL BLOCK AND TEMPORARY SUPPORT WILL BE REMOVED ONCE CHARGERS ARE INSTALLED. 2.SECURELY FASTEN PVC CONDUIT TO CONDUIT SUPPORT WITH 1/4" WIDE UV STABILIZED NYLON CABLE TIES. PROVIDE 1 TIE EVERY 12". FIELD FIT CONDUIT ATTACHMENT AND CONFIGURATION AS NEEDED TO FIT WITHIN THE 3.2'' X 3.2'' OPENING AS SHOWN IN SECTION A-A 3.PARTS INCLUDED IN THE BILL OF MATERIALS ARE FOR 1 TEMPORARY TERMINAL BLOCK ONLY. SEE ELECTRICAL CONDUIT PLAN FOR LOCATION AND COUNT. BILL OF MATERIALS (1 UNIT) REFERENCE NUMBER ITEM QUANTITY 1 VYNCKIER VM554 ENCLOSURE 1 EA 2 VYNCKIER BACKING PLATE VMBP55A 1 EA 3 TERMINAL BLOCK BUSSMANN 14004-6, 90A, #4-14 AWG CU, 600 VAC 1 EA 4 EATON B-LINE B22SH120 HDG, 12GA, 10' LENGTHS 1 EA 5 B-LINE 1/4 X 1.25" 20 HHCS ZINC 2 EA 6 B-LINE SPRING NUT, N224, 1/4 - 20 2 EA 7 UV STABILIZED NYLON CABLE TIES (1/4" WIDTH)5 EA 10 " 2' 2' 2' 1' 11" C2 RISER PAYMENT KIOSK SECTION A-A (K1) 1'-1" 4 PVC ELECTRICAL CONDUIT RISER SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ d t 0 2 . d w g ; La y o u t 1 ( 2 ) - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 6 p m 00002112309 Date Signed: 06-17-2025 PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 8CONDUIT SECTIONS AND DETAILS E2.1 A E2.1 PAYMENT KIOSK CONCRETE PAD AND TEMPORARY TERMINAL BLOCK NOT TO SCALE NOTE: 1.SEE NOTES ON SHEET E2.0 B E2.1 EV CHARGER CONCRETE PAD AND TEMPORARY TERMINAL BLOCK NOT TO SCALE C E2.1 EV CHARGER CONCRETE PAD AND TEMPORARY TERMINAL BLOCK WITH ADDED WIRELESS ACCESS POINT NOT TO SCALE YΔ M 1912 12kV, 150kVA, 208Y/120V, 3Ø, 4W SERVICE CT METER AND MAIN SWITCHBOARD, 600 AMP BUS, 600 AMP MAIN, 208Y/120V, 3Ø, 4W, 42 kAIC MINIMUM 2P 40A40A 2P 40A 2P 17 18 40A 2P 40A 2P (NEMA 3R) TO EVSE-10 CHARGE PORT 19 (32 FLA) PROPOSED UTILITY TRANSFORMER (kVA RATING PER SCE) PULL SECTION CT METERING SECTION LANDING LUGS (TYP) MAIN 600A 3P TO EVSE-1 CHARGE PORTS 1&2 (32 FLA + 32 FLA) TO EVSE-9 CHARGE PORTS 17&18 (32 FLA + 32 FLA) 20 2P 40A TO EVSE-11 CHARGE PORT 20 (32 FLA) 1" U.G. PVC WITH (4) #8 Cu AND (2) #8 Cu GND (TYP FOR EVSE-1 THROUGH EVSE-9) 1" U.G. PVC WITH (2) #8 Cu AND (1) #8 Cu GND (TYP FOR EVSE-10 AND EVSE-11) 1P 20A TO NEXUS CONTROLLER (1.7 FLA) 1P 20A TO PAYMENT KIOSK (10 FLA) 1" U.G. PVC TO TRANSITION TO 1" A.G. RMC WITH (2) #12 Cu AND (1) #12 Cu GND 1" U.G. PVC WITH (2) #12 Cu AND (1) #12 Cu GND CT A B C N G TO 600A DISTRIBUTION SECTION #2/0 Cu MAIN BONDING JUMPER #2 BARE Cu (2) 5/8" Cu CLAD 8' GROUND ROD 600A / 3P (P1,P2) G N SERVICE CT METER AND MAIN SWITCHBOARD BUS AMPS: 600 NEMA: 3R MFR: Z POWER LOC: KAISER FOUNDATION HEALTH PLAN MTG: PAD MOUNT MAIN AMPS: 600 PHASE: 3 WIRES: 4 VOLTS: 208Y/120V FEEDER: PER UTILITY FEEDER ENTRY AT: BOTTOM AIC RATING: 42,000A SYM. DESCRIPTION VOLT-AMPS BKR TRIP CKT L1 L2 L3 CKT BKR TRIP VOLT-AMPS DESCRIPTION L1 L2 L3 L1 L2 L3 EVSE-1 (CHARGE PORT 1) 3328.0 0.0 0.0 40A/2P 1 2 40A/2P 3328.0 0.0 0.0 EVSE-1 (CHARGE PORT 2)0.0 3328.0 0.0 3 4 0.0 3328.0 0.0 EVSE-2 (CHARGE PORT 3) 0.0 0.0 3328.0 40A/2P 5 6 40A/2P 0.0 0.0 3328.0 EVSE-2 (CHARGE PORT 4)3328.0 0.0 0.0 7 8 3328.0 0.0 0.0 EVSE-3 (CHARGE PORT 5) 0.0 3328.0 0.0 40A/2P 9 10 40A/2P 0.0 3328.0 0.0 EVSE-3 (CHARGE PORT 6)0.0 0.0 3328.0 11 12 0.0 0.0 3328.0 EVSE-4 (CHARGE PORT 7) 3328.0 0.0 0.0 40A/2P 13 14 40A/2P 3328.0 0.0 0.0 EVSE-4 (CHARGE PORT 8)0.0 3328.0 0.0 15 16 0.0 3328.0 0.0 EVSE-5 (CHARGE PORT 9) 0.0 0.0 3328.0 40A/2P 17 18 40A/2P 0.0 0.0 3328.0 EVSE-5 (CHARGE PORT 10)3328.0 0.0 0.0 19 20 3328.0 0.0 0.0 EVSE-6 (CHARGE PORT 11) 0.0 3328.0 0.0 40A/2P 21 22 40A/2P 0.0 3328.0 0.0 EVSE-6 (CHARGE PORT 12)0.0 0.0 3328.0 23 24 0.0 0.0 3328.0 EVSE-7 (CHARGE PORT 13) 3328.0 0.0 0.0 40A/2P 25 26 40A/2P 3328.0 0.0 0.0 EVSE-7 (CHARGE PORT 14)0.0 3328.0 0.0 27 28 0.0 3328.0 0.0 EVSE-8 (CHARGE PORT 15) 0.0 0.0 3328.0 40A/2P 29 30 40A/2P 0.0 0.0 3328.0 EVSE-8 (CHARGE PORT 16)3328.0 0.0 0.0 31 32 3328.0 0.0 0.0 EVSE-9 (CHARGE PORT 17) 0.0 3328.0 0.0 40A/2P 33 34 40A/2P 0.0 3328.0 0.0 EVSE-9 (CHARGE PORT 18)0.0 0.0 3328.0 35 36 0.0 0.0 3328.0 EVSE-10 (CHARGE PORT 19) 3328.0 0.0 0.0 40A/2P 37 38 40A/2P 3328.0 0.0 0.0 EVSE-11 (CHARGE PORT 20)0.0 3328.0 0.0 39 40 0.0 3328.0 0.0 POWERFLEX NEXUS CORE 0.0 0.0 65.0 20A/1P 41 42 20A/1P 0.0 0.0 1200.0 PAYMENT KIOSK -0.0 0.0 0.0 -43 44 -0.0 0.0 0.0 - -0.0 0.0 0.0 -45 46 -0.0 0.0 0.0 - -0.0 0.0 0.0 -47 48 -0.0 0.0 0.0 - CONNECTED LOAD >23296.0 23296.0 20033.0 ESTIMATED TOTAL VOLT-AMPERES 23296.0 23296.0 21168.0 < CONNECTED LOAD LINE 1 AMP: 388.3A L1 L2 L3 REMARKS: LINE 2 AMP: 388.3A 46592.0 VA 46592.0 VA 41201.0 VA 141.5KVA TOTAL ESTIMATED CONNECTED LOAD LINE 3 AMP: 343.3A SHEETSOF SHEET NO. SCALE AS NOTED DATE: CH. BY: DR. BY: REF. & REV. CONSULTANT 06-17-2025 12 CR GSKAISER FOUNDATION HEALTH PLAN CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON Dr a w i n g : P: \ 2 2 1 \ 2 2 1 - 0 2 2 3 \ S i t e \ 0 0 0 0 2 1 1 2 3 0 9 _ K F H P \ C D P h a s e \ P r o d u c t i o n D r a w i n g s \ 21 1 2 3 0 9 _ K F H P _ d t 0 3 . d w g ; La y o u t 1 - BC F . c t b Pl o t b y : dp a r t i d a Oc t 2 3 , 2 0 2 5 - 1 : 5 6 p m 00002112309 Date Signed: 06-17-2025 PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 9ELECTRICAL SCHEDULE AND CIRCUITS E3.0 A E3.0 SINGLE LINE DIAGRAM NOT TO SCALE B E3.0 SERVICE CT METER WIRING DIAGRAM NOT TO SCALE C E3.0 SERVICE CT METER AND MAIN SWITCHBOARD LOAD SCHEDULE NOT TO SCALE # ### NOTES: 1.TOTAL CONNECTED 3-PH KVA: 141.5 KVA AT 0.95 PF 2.TYPE 42 KAIC BRANCH BREAKERS 3.TAGGED (CHARGE PORT-#, L1/L2/GND) TYPICAL FOR ALL STATIONS. 4.DO NOT USE GFCI BREAKERS 6.STANDARD RATED SERVICE PANELS, OVER CURRENT PROTECTION DEVICES AND WIRE SIZES BASED ON CEC/NEC REQUIREMENTS AT 125% CONTINUOUS LOAD. 100% RATED SERVICE PANELS, OVER CURRENT PROTECTION DEVICES AND WIRE SIZES BASED ON CEC/NEC REQUIREMENTS AT 100% CONTINUOUS LOAD. 7.INDIVIDUAL CHARGER INPUT: 32A PER PROPOSED MANUFACTURER LITEON SC48 8.TRANSFORMER LOADING BASED ON KVA REQUIREMENTS OF CHARGER AT 0.95 PF PER SCE (6.7KVA/CHARGER). 9. , INDIVIDUAL CHARGE PORT NUMBER. THIS IS NOT BREAKER SPACE OR EVSE NUMBER. LOAD SCHEDULE INDICATES BREAKER SPACE FOR EACH CHARGE PORT. 10. , INDIVIDUAL CHARGE PORT NUMBER TYPICAL FOR PORTS THROUGH . 11.ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 12.PER CEC/NEC 210.19 (A) INFORMATIONAL NOTE #4, "CONDUCTORS FOR BRANCH CIRCUITS AS DEFINED IN ARTICLE 100, SIZED TO PREVENT A VOLTAGE DROP EXCEEDING 3 PERCENT AT THE FARTHEST OUTLET OF POWER, HEATING, AND LIGHTING LOADS, OR COMBINATION OF SUCH LOADS, AND WHERE THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO THE FARTHEST OUTLET DOES NOT EXCEED 5%." 13.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION. 14.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. 15.MAXIMUM VOLTAGE DROP FOR CONDUCTORS: #12 WIRE = 2.2% #8 WIRE = 2.2% 16.ALL ELECTRICAL EQUIPMENT SHALL BE LISTED FOR TERMINATION OF ELECTRICAL CONDUCTORS RATED 75°C OR HIGHER. 17.ALL BREAKERS INSTALLED UNDER THIS DESIGN SHALL BE ABLE TO BE LOCKED IN THE OPEN POSITION PER NEC 625.43 AND 110.25. 18.CHARGER INSTALLER MUST MANUALLY SET THE INPUT AMPERAGE TO POSITION 4 AT 32 AMPS. REFER TO INSTALLATION MANUAL FOR FURTHER DETAILS. # YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs