Loading...
HomeMy WebLinkAbout109 E 4th St - PlanTITLE SHEET 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C ARTE RESTAURANT 109 E 4TH ST., SANTA ANA, CA 92701 ARCHITECTURAL T-1.0 TITLE SHEET SP-1.0 SITE PLAN A-0.1 ACCESSIBILITY DETAILS A-0.2 ACCESSIBILITY DETAILS A-1.0 EXISTING FLOOR PLAN A-1.1 PROPOSED FLOOR PLAN A-2.0 EGRESS & ENLARGED RESTROOM PLAN A-2.1 CEILING PLAN A-2.2 FINISH PLAN A-3.0 DETAILS A-3.1 DETAILS EQ-1.0 EQUIPMENT PLAN, INTERIOR ELEVATION & SCHEDULE VICINITY MAP GENERAL NOTES 1 THE GENERAL CONTRACTOR AND HIS SUBCONTRACTORS SHALL VERIFY ALL CONDITIONS, DIMENSIONS, ETC. AT THE SITE AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT IN WRITING PRIOR TO CONSTRUCTION. COMMENCEMENT OF WORK IMPLIES THE ACCEPTANCE OF ALL CONDITIONS. CONTRACTOR SHALL ALSO COORDINATE THE WORK WITH THE WORK OF ALL OTHER TRADES. 2 THE GENERAL CONTRACTOR SHALL PROVIDE ALL PROTECTIVE MEASURES FOR THE SAFETY OF THE PUBLIC AND WORKERS DURING THE COURSE OF THE WORK. 3 ALL WORK ON THIS PROJECT SHALL BE DONE IN THE BEST WORKMANSHIP. 4 THE GENERAL CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR THE EXECUTION OF HIS WORK AND FOR ANY CHANGES AND/OR DEVIATIONS FROM DRAWINGS AND SPECIFICATIONS MADE WITHOUT PRIOR WRITTEN APPROVAL FROM THE OWNER. THE COST OF CORRECTIONS RESULTING FROM CHANGES AND/OR DEVIATIONS SHALL BE BORNE BY THE GENERAL CONTRACTOR. 5 DESIGN ALTERATIONS MADE WITHOUT THE ARCHITECT'S KNOWLEDGE DURING THE COURSE OF CONSTRUCTION ARE DONE AT THE OWNER'S AND/OR CONTRACTOR'S RISK. THE ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR THE CONSEQUENCES OF SUCH CHANGES. 6 THE GENERAL AND SUB-CONTRACTORS SHALL APPLY FOR AND PAY FOR ALL PERMITS REQUIRED FOR THIS PROJECT. 7 A COMPLETE SET OF CONTRACT DOCUMENTS MUST BE KEPT AT THE JOB SITE AT ALL TIMES AND ANY CHANGES MUST BE NOTED THEREON AND INITIALED. 8 THE CONTRACTOR SHALL INSURE THE PROTECTION OF ALL EQUIPMENT FURNISHED UNDER HIS CONTRACT AND BY OTHERS. 9 THE GENERAL CONTRACTOR SHALL DO ALL WALL AND FLOOR PATCHING TO CONFORM TO MATERIAL, TEXTURE, AND SURFACE ALIGNMENT WITH THE ADJOINING SURFACE. 10 PROVIDE PROTECTION AROUND AREAS WHERE NEW WORK AND/OR DEMOLITION IS TO BE PERFORMED IN ORDER TO PREVENT DUST AND DIRT FROM ENTERING ACTIVE PORTIONS OF THE BUILDING. 11 PATCH, REPAIR, OR REPLACE ALL WORK DAMAGED BY NEW CONSTRUCTION. 12 REMOVE ALL DEBRIS AT THE COMPLETION OF THE PROJECT. 13 DO NOT SCALE DRAWINGS FOR ANY REASON. REPORT ANY DIMENSIONAL DISCREPANCIES TO THE ARCHITECT BEFORE CONTINUING WORK. 14 WHERE LISTED, PRODUCT DISTRIBUTORS ARE PROVIDED FOR CONVENIENCE ONLY. THE CONTRACTOR IS NOT REQUIRED TO USE THE LISTED DISTRIBUTORS. 15 GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION AS REQUIRED FOR COMPLETION OF THE PROJECT. REMOVE ALL DEMOLISHED MATERIAL, NOT DESIGNATED FOR RE-USE, FROM THE PREMISES. LEAVE THE PREMISES CLEAN, NEAT AND ORDERLY AT THE COMPLETION OF THE PROJECT. 16 REPLACE OR RELOCATE ALL EXISTING PIPELINE, CONDUIT, WIRING, ETC. REQUIRED FOR THE COMPLETION OF THE NEW WORK. 17 THE ARCHITECT HAS NO KNOWLEDGE OF HAZARDOUS MATERIAL ON THIS PROJECT. THE ARCHITECT CAN NOT BE HELD LIABLE FOR ANY SUCH MATERIAL ASBESTOS, LEAD PAINT OR OTHER SIMILAR PRODUCT THAT MAY BE UNCOVERED ON THIS PROJECT. IF SUCH MATERIAL IS ENCOUNTERED OR SUSPECTED, THE OWNER SHALL BE RESPONSIBLE FOR MAKING ARRANGEMENTS FOR THE SAFE AND LEGAL REMOVAL OF SUCH MATERIAL AS REQUIRED. 18 THE ARCHITECT HAS NO CONTROL OR RESPONSIBILITY FOR THE MEANS, TECHNIQUES SEQUENCE, OR PROCEDURES OF CONSTRUCTION OR SAFETY PROGRAMS FOR THIS PROJECT. SUCH PROGRAMS AND COMPLIANCE WITH ALL LAWS, REULES, REGULATIONS, CODES OR ORDINANCES SHALL BE THE RESPONSIBILITY OF OTHERS. 19 THE REMOVAL OF FLOOR SLAB FOR INSTALLATION OF SANITARY AND/OR WATER LINES SHALL BE ACCOMPLISHED BY SAW CUTTING. 20 PENETRATIONS OF THE ROOF LARGER THAN 2'-0" X 2'-0" FOR INSTALLATION OF ROOF MOUNTED EQUIPMENT SHALL REQUIRED A STEEL SUPPORT FRAME TO CARRY THE LOAD TO THE BUILDING'S STEEL STRUCTURE. 21 ANY WORK THAT REQUIRES PENETRATING THE ROOF SYSTEM SHALL BE PERFORMED BY A ROOFING CONTRACTOR APPROVED BY THE LANDLORD. 22 ELECTRICAL CONDUIT, WATER LINE, DUCT SUPPORTS/HANGERS, ETC. SHALL NOT BE ATTACHED TO THE UNDERSIDE OF THE ROOF DECK. 23 IT IS THE ARCHITECT OF RECORD’S RESPONSIBILITY TO CHECK AND CONFIRM THE EXISTING ACCESSIBILITY FEATURES SHOWN IN REFERENCE DRAWINGS SUBMITTED PRIOR TO THE PERMIT BEING ISSUED. SUBMITTED PLANS MUST INCLUDE DETAILED CONFIRMATION OF EXISTING DISABLED ACCESS FEATURES AND/OR ANY REQUIRED DISABLED ACCESS IMPROVEMENTS. SCOPE OF WORK TENANT IMPROVEMENT OF AN EXISTING SHELL TENANT SPACE FOR RESTAURANT. SCOPE INCLUDES ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL. NO STRUCTURAL WORK. ● INSTALL NEW NON-LOAD BEARING PARTITION WALLS ● INSTALL NEW SUSPENDED CEILING ● INSTALL NEW PLUMBING FIXTURES ● INSTALL NEW LIGHTING FIXTURES, RECEPTACLES, ELECTRICAL PANEL ● INSTALL NEW TYPE I HOOD & HVAC DUCTING ● INSTALL NEW KITCHEN EQUIPMENT SEPARATE PERMIT BUILDING SIGNAGE ARCHITECT CONTACT:DAVID KANG ADDRESS:9890 RESEARCH DR., STE 100 IRVINE, CA 92618 TEL:(949) 533-4117 EMAIL:DKANG@CDIENG.COM OWNER CONTACT:JOSE ADDRESS:109 E 4TH ST., SANTA ANA, CA 92701 TEL:(714) 873-8503 EMAIL:ARTEDTSA@GMAIL.COM PROJECT DESCRIPTION LEGAL JURISDICTION:CITY OF SANTA ANA, CA BUILDING CODE:2022 CALIFORNIA BUILDING CODE MECHANICAL CODE:2022 CALIFORNIA MECHANICAL CODE PLUMBING CODE:2022 CALIFORNIA PLUMBING CODE ELECTRICAL CODE:2022 CALIFORNIA ELECTRICAL CODE FIRE CODE:2022 CALIFORNIA FIRE CODE ENERGY:2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS GREEN BUILDING CODE:2022 CALIFORNIA GREEN BUILDING STANDARD CODE N MEP CONTACT:DAVID KANG ADDRESS:9890 RESEARCH DR., STE 100 IRVINE, CA 92618 TEL:(949) 533-4117 EMAIL:DKANG@CDIENG.COM T-1.0 OCCUPANT LOAD CALCULATION FUNCTION ROOM NUMBER AREA/ LENGTH FACTOR OCCUPANT LOAD DINING AREA 101 784 SF 15 53 SERVICE AREA 102 250 SF 100 3 HALLWAY 103 55 SF 0 0 STORAGE 104 55 SF 200 1 WOMAN'S RESTROOM 105 77 SF 0 0 MAN'S RESTROOM 106 82 SF 0 0 KITCHEN AREA 107 335 SF 200 2 OUTDOOR DINING PATIO 108 348 SF 15 23 TOTAL 1986 82 MECHANICAL M000 MECHANICAL NOTES M001 MECHANICAL SCHEDULE M002 MECHANICAL DETAILS M100 MECHANICAL PLAN TM00 MECHANICAL TITLE 24 - 1 PLUMBING P000 PLUMBING NOTES & SCHEDULES P001 PLUMBING DETAILS P100 WASTE & VENT PLAN P200 WATER PLAN P300 GAS PLAN TP00 TITLE 24 ELECTRICAL E000 ELECTRICAL SPECIFICATION E001 SINGLE LINE DIAGRAM & SCHEDULES E100 LIGHTING PLAN E200 POWER PLAN TE00 TITLE 24 - INDOOR BUILDING INFORMATION OCCUPANCY:A-2 CONSTRUCTION TYPE:IIIA (EXISTING) FIRE ALARM:YES (EXISTING) FIRE SPRINKLER:YES (EXISTING) T.I. AREA:2,005 SF DEFERRED SUBMITTAL NOTES 1 COMPLETE PLANS, SPECIFICATIONS, MATERIAL DATA AND/ OR CALCULATIONS FOR THE DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED IN A TIMELY MANNER BUT NOT LESS THAN BUSINESS DAYS PRIOR INSTALLATION FOR CITY OF SAN DIEGO REVIEW AND APPROVAL. 2 THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. 3 THE REGISTERED AND RESPONSIBLE DESIGN PROFESSIONAL SHALL REVIEW THE DEFERRED SUBMITTAL DOCUMENTS AND SUBMIT THEM TO THE BUILDING, WITH ANNOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEW AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. APPLICANT CONTACT:JOSE ADDRESS:109 E 4TH ST., SANTA ANA, CA 92701 TEL:(714) 873-8503 EMAIL:ARTEDTSA@GMAIL.COM 3 3 DEFERRED SUBMITTAL FIRE SPRINKLER FIRE ALARM 3 TITLE SHEET 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C ARTE RESTAURANT 109 E 4TH ST., SANTA ANA, CA 92701 ARCHITECTURAL T-1.0 TITLE SHEET SP-1.0 SITE PLAN A-0.1 ACCESSIBILITY DETAILS A-0.2 ACCESSIBILITY DETAILS A-1.0 EXISTING FLOOR PLAN A-1.1 PROPOSED FLOOR PLAN A-2.0 EGRESS & ENLARGED RESTROOM PLAN A-2.1 CEILING PLAN A-2.2 FINISH PLAN A-3.0 DETAILS A-3.1 DETAILS EQ-1.0 EQUIPMENT PLAN, INTERIOR ELEVATION & SCHEDULE VICINITY MAP GENERAL NOTES 1 THE GENERAL CONTRACTOR AND HIS SUBCONTRACTORS SHALL VERIFY ALL CONDITIONS, DIMENSIONS, ETC. AT THE SITE AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT IN WRITING PRIOR TO CONSTRUCTION. COMMENCEMENT OF WORK IMPLIES THE ACCEPTANCE OF ALL CONDITIONS. CONTRACTOR SHALL ALSO COORDINATE THE WORK WITH THE WORK OF ALL OTHER TRADES. 2 THE GENERAL CONTRACTOR SHALL PROVIDE ALL PROTECTIVE MEASURES FOR THE SAFETY OF THE PUBLIC AND WORKERS DURING THE COURSE OF THE WORK. 3 ALL WORK ON THIS PROJECT SHALL BE DONE IN THE BEST WORKMANSHIP. 4 THE GENERAL CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR THE EXECUTION OF HIS WORK AND FOR ANY CHANGES AND/OR DEVIATIONS FROM DRAWINGS AND SPECIFICATIONS MADE WITHOUT PRIOR WRITTEN APPROVAL FROM THE OWNER. THE COST OF CORRECTIONS RESULTING FROM CHANGES AND/OR DEVIATIONS SHALL BE BORNE BY THE GENERAL CONTRACTOR. 5 DESIGN ALTERATIONS MADE WITHOUT THE ARCHITECT'S KNOWLEDGE DURING THE COURSE OF CONSTRUCTION ARE DONE AT THE OWNER'S AND/OR CONTRACTOR'S RISK. THE ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR THE CONSEQUENCES OF SUCH CHANGES. 6 THE GENERAL AND SUB-CONTRACTORS SHALL APPLY FOR AND PAY FOR ALL PERMITS REQUIRED FOR THIS PROJECT. 7 A COMPLETE SET OF CONTRACT DOCUMENTS MUST BE KEPT AT THE JOB SITE AT ALL TIMES AND ANY CHANGES MUST BE NOTED THEREON AND INITIALED. 8 THE CONTRACTOR SHALL INSURE THE PROTECTION OF ALL EQUIPMENT FURNISHED UNDER HIS CONTRACT AND BY OTHERS. 9 THE GENERAL CONTRACTOR SHALL DO ALL WALL AND FLOOR PATCHING TO CONFORM TO MATERIAL, TEXTURE, AND SURFACE ALIGNMENT WITH THE ADJOINING SURFACE. 10 PROVIDE PROTECTION AROUND AREAS WHERE NEW WORK AND/OR DEMOLITION IS TO BE PERFORMED IN ORDER TO PREVENT DUST AND DIRT FROM ENTERING ACTIVE PORTIONS OF THE BUILDING. 11 PATCH, REPAIR, OR REPLACE ALL WORK DAMAGED BY NEW CONSTRUCTION. 12 REMOVE ALL DEBRIS AT THE COMPLETION OF THE PROJECT. 13 DO NOT SCALE DRAWINGS FOR ANY REASON. REPORT ANY DIMENSIONAL DISCREPANCIES TO THE ARCHITECT BEFORE CONTINUING WORK. 14 WHERE LISTED, PRODUCT DISTRIBUTORS ARE PROVIDED FOR CONVENIENCE ONLY. THE CONTRACTOR IS NOT REQUIRED TO USE THE LISTED DISTRIBUTORS. 15 GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION AS REQUIRED FOR COMPLETION OF THE PROJECT. REMOVE ALL DEMOLISHED MATERIAL, NOT DESIGNATED FOR RE-USE, FROM THE PREMISES. LEAVE THE PREMISES CLEAN, NEAT AND ORDERLY AT THE COMPLETION OF THE PROJECT. 16 REPLACE OR RELOCATE ALL EXISTING PIPELINE, CONDUIT, WIRING, ETC. REQUIRED FOR THE COMPLETION OF THE NEW WORK. 17 THE ARCHITECT HAS NO KNOWLEDGE OF HAZARDOUS MATERIAL ON THIS PROJECT. THE ARCHITECT CAN NOT BE HELD LIABLE FOR ANY SUCH MATERIAL ASBESTOS, LEAD PAINT OR OTHER SIMILAR PRODUCT THAT MAY BE UNCOVERED ON THIS PROJECT. IF SUCH MATERIAL IS ENCOUNTERED OR SUSPECTED, THE OWNER SHALL BE RESPONSIBLE FOR MAKING ARRANGEMENTS FOR THE SAFE AND LEGAL REMOVAL OF SUCH MATERIAL AS REQUIRED. 18 THE ARCHITECT HAS NO CONTROL OR RESPONSIBILITY FOR THE MEANS, TECHNIQUES SEQUENCE, OR PROCEDURES OF CONSTRUCTION OR SAFETY PROGRAMS FOR THIS PROJECT. SUCH PROGRAMS AND COMPLIANCE WITH ALL LAWS, REULES, REGULATIONS, CODES OR ORDINANCES SHALL BE THE RESPONSIBILITY OF OTHERS. 19 THE REMOVAL OF FLOOR SLAB FOR INSTALLATION OF SANITARY AND/OR WATER LINES SHALL BE ACCOMPLISHED BY SAW CUTTING. 20 PENETRATIONS OF THE ROOF LARGER THAN 2'-0" X 2'-0" FOR INSTALLATION OF ROOF MOUNTED EQUIPMENT SHALL REQUIRED A STEEL SUPPORT FRAME TO CARRY THE LOAD TO THE BUILDING'S STEEL STRUCTURE. 21 ANY WORK THAT REQUIRES PENETRATING THE ROOF SYSTEM SHALL BE PERFORMED BY A ROOFING CONTRACTOR APPROVED BY THE LANDLORD. 22 ELECTRICAL CONDUIT, WATER LINE, DUCT SUPPORTS/HANGERS, ETC. SHALL NOT BE ATTACHED TO THE UNDERSIDE OF THE ROOF DECK. 23 IT IS THE ARCHITECT OF RECORD’S RESPONSIBILITY TO CHECK AND CONFIRM THE EXISTING ACCESSIBILITY FEATURES SHOWN IN REFERENCE DRAWINGS SUBMITTED PRIOR TO THE PERMIT BEING ISSUED. SUBMITTED PLANS MUST INCLUDE DETAILED CONFIRMATION OF EXISTING DISABLED ACCESS FEATURES AND/OR ANY REQUIRED DISABLED ACCESS IMPROVEMENTS. SCOPE OF WORK TENANT IMPROVEMENT OF AN EXISTING SHELL TENANT SPACE FOR RESTAURANT. SCOPE INCLUDES ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL. NO STRUCTURAL WORK. ● INSTALL NEW NON-LOAD BEARING PARTITION WALLS ● INSTALL NEW SUSPENDED CEILING ● INSTALL NEW PLUMBING FIXTURES ● INSTALL NEW LIGHTING FIXTURES, RECEPTACLES, ELECTRICAL PANEL ● INSTALL NEW TYPE I HOOD & HVAC DUCTING ● INSTALL NEW KITCHEN EQUIPMENT SEPARATE PERMIT BUILDING SIGNAGE ARCHITECT CONTACT:DAVID KANG ADDRESS:9890 RESEARCH DR., STE 100 IRVINE, CA 92618 TEL:(949) 533-4117 EMAIL:DKANG@CDIENG.COM OWNER CONTACT:JOSE ADDRESS:109 E 4TH ST., SANTA ANA, CA 92701 TEL:(714) 873-8503 EMAIL:ARTEDTSA@GMAIL.COM PROJECT DESCRIPTION LEGAL JURISDICTION:CITY OF SANTA ANA, CA BUILDING CODE:2022 CALIFORNIA BUILDING CODE MECHANICAL CODE:2022 CALIFORNIA MECHANICAL CODE PLUMBING CODE:2022 CALIFORNIA PLUMBING CODE ELECTRICAL CODE:2022 CALIFORNIA ELECTRICAL CODE FIRE CODE:2022 CALIFORNIA FIRE CODE ENERGY:2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS GREEN BUILDING CODE:2022 CALIFORNIA GREEN BUILDING STANDARD CODE N MEP CONTACT:DAVID KANG ADDRESS:9890 RESEARCH DR., STE 100 IRVINE, CA 92618 TEL:(949) 533-4117 EMAIL:DKANG@CDIENG.COM T-1.0 OCCUPANT LOAD CALCULATION FUNCTION ROOM NUMBER AREA/ LENGTH FACTOR OCCUPANT LOAD DINING AREA 101 784 SF 15 53 SERVICE AREA 102 250 SF 100 3 HALLWAY 103 55 SF 0 0 STORAGE 104 55 SF 200 1 WOMAN'S RESTROOM 105 77 SF 0 0 MAN'S RESTROOM 106 82 SF 0 0 KITCHEN AREA 107 335 SF 200 2 OUTDOOR DINING PATIO 108 348 SF 15 23 TOTAL 1986 82 MECHANICAL M000 MECHANICAL NOTES M001 MECHANICAL SCHEDULE M002 MECHANICAL DETAILS M100 MECHANICAL PLAN TM00 MECHANICAL TITLE 24 - 1 PLUMBING P000 PLUMBING NOTES & SCHEDULES P001 PLUMBING DETAILS P100 WASTE & VENT PLAN P200 WATER PLAN P300 GAS PLAN TP00 TITLE 24 ELECTRICAL E000 ELECTRICAL SPECIFICATION E001 SINGLE LINE DIAGRAM & SCHEDULES E100 LIGHTING PLAN E200 POWER PLAN TE00 TITLE 24 - INDOOR BUILDING INFORMATION OCCUPANCY:A-2 CONSTRUCTION TYPE:IIIA (EXISTING) FIRE ALARM:YES (EXISTING) FIRE SPRINKLER:YES (EXISTING) T.I. AREA:2,005 SF DEFERRED SUBMITTAL NOTES 1 COMPLETE PLANS, SPECIFICATIONS, MATERIAL DATA AND/ OR CALCULATIONS FOR THE DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED IN A TIMELY MANNER BUT NOT LESS THAN BUSINESS DAYS PRIOR INSTALLATION FOR CITY OF SAN DIEGO REVIEW AND APPROVAL. 2 THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. 3 THE REGISTERED AND RESPONSIBLE DESIGN PROFESSIONAL SHALL REVIEW THE DEFERRED SUBMITTAL DOCUMENTS AND SUBMIT THEM TO THE BUILDING, WITH ANNOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEW AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. APPLICANT CONTACT:JOSE ADDRESS:109 E 4TH ST., SANTA ANA, CA 92701 TEL:(714) 873-8503 EMAIL:ARTEDTSA@GMAIL.COM 3 3 DEFERRED SUBMITTAL FIRE SPRINKLER FIRE ALARM 3 ACCESSIBILITY INFORMATION 1.ACCESS TO THESE FACILITIES SHALL BE PROVIDED AT PRIMARY ENTRANCES. 2.THE SLOPE OF PUBLIC WALKS SHALL NOT EXCEED MAX. CROSS SLOPE 2 %. 3.WALKING SURFACES SLOPING GREATER THAN 2 % SHALL BE SLIP RESISTANT. 4.PROVIDE A 60" x 60" MIN. LANDING ON STRIKE SIDE OF DOOR WITH 44" MINIMUM WIDTH IN DIRECTION OF TRAVEL. 5.WALKS SHALL EXTEND 24" TO THE SIDE OF THE STRIKE EDGE OF DOOR OR GATE THAT SWINGS TOWARD THE WALK. 6.EVERY REQUIRED EXIT DOORWAY SHALL BE SIZED FOR A DOOR NOT LESS THAN 3'-0" WIDE BY 6'-8" HIGH CAPABLE OF OPENING 90 DEGREES AND MOUNTED SO THAT THE CLEAR WIDTH OF THE EXIT SHALL BE A MINIMUM OF 32". 7.THRESHOLDS TO BE A MAXIMUM OF 1/2"ABOVE THE ADJACENT FINISHED FLOOR. 8.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS FOR INTERIOR DOORS AND 15 LBS FOR EXTERIOR DOORS. 9.THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC SLIDERS SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE. 10.THE BUILDING SHALL COMPLY WITH THE 2010 AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIIDELINES (ADAAG) AND ANSI A117.1-2009, INCLUDING BUT NOT LIMITED TO IBC CHAPTER 11. 11.CONTROLS AND OPERATING MECHANISMS SHALL BE ACCESSIBLE AND HAVE MOUNTING HEIGHTS COMPLYING WITH ANSI 4.27. 12.ALL ROOM, DIRECTIONAL, AND INFORMATION SIGNS SHALL BE ACCESSIBLE DESIGN COMPLYING WITH ANSI 4.13 AND 4.30. ACCESSIBILITY DETAILS 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C 30" MIN. 48 " M I N . X > 24" 30 " M I N . 48" MIN. 30 " M I N . X > 2 4 " X > 1 5 " 48 " M I N . 42 " M I N . 60" MIN.36" MIN. ALL GENDER WOMENALL GENDER EXIT MEN STAIRS MO U N T C E N T E R EDGE OF DOOR FRAME 1 1/2" HIGH WHITE LETTERING ON BLACK BACKGROUND9" 60 " A . F . F . INTERNATIONAL TDD SYMBOL FIGURE 703.6.3.2 BLUE PLASTIC (FIELD) BACKGROUND w/ WHITE RAISED OR DEPRESSED EMBLEMS (NOTE- EMBLEMS & LETTERING MUST BE RAISED OR DEPRESSED MIN. 1/32" TYPICAL) INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS FIGURE 703.6.3.3 PROVIDE (1) SIGN PER TOILET COMPLYING WITH ANSI 2009, SECTION 703. SIGN TO HAVE RAISED AND BRAILLE CHARACTERS AND PICTORIAL SYMBOL OF ACCESSIBILITY. MOUNT 5'-0" TO CENTERLINE A.F.F. INTERNATIONAL SYMBOL OF ACCESSIBILITY FIGURE 703.6.3.1 6" M I N . 48 " M I N . X = 22" MIN. 42 " M I N . 42 " M I N . X = 24" MIN. 6" M I N . 6" M I N . 60" MIN. 12" MIN. 6" M I N . 6" M I N . 6" M I N . 12" MIN. 60 " M I N . 36" MIN. 36 " M I N . 32 " M I N . 36 " M I N . 32 " M I N . 36 " M I N . 24" MAX.48" MIN.24" MAX. CIRCULAR FIGURE 304.3 (a) T-SHAPED FIGURE 304.3 (b)FIGURE 403.5 32" MIN. 90° HINGED DOOR FIGURE 404.2.2 (a) 32" MIN. SLIDING DOOR FIGURE 404.2.2 (b) FOLDING DOOR FIGURE 404.2.2 (c) DOORWAYS WITHOUT DOORS FIGURE 404.2.2 (d) 36" MIN. 32" MIN. 24 " M A X . 60 " M I N . 60" MIN. FIGURE 404.2.5 (a)FIGURE 404.2.5 (c)FIGURE 404.2.5 (b) ARC OF DOOR SWING IN FIELD SEE FIGURE 12/A0.2 1/ 2 " M A X . REFUGE AREA OF AREA OF REFUGE48 " M I N . 42" MIN. FIGURE 403.5.1 CLEAR WIDTH AT 180 DEGREE TURN 36" MIN. 180 DEGREE TURN X < 48"X < 48" 180 DEGREE TURN (EXCEPTION) 42" MIN.36" MIN. 60 " M I N . 24 " 1/4" MAX. 48 " M A X . 48 " M A X . 1/ 4 " M A X . 34 " M A X . 1/4" MAX. 34 " M A X . UNOBSTRUCTED HIGH SIDE REACH FIGURE 308.3.2 (a) UNOBSTRUCTED SIDE REACH FIGURE 308.3.1 10" - 24" MAX. 46 " M A X . UNOBSTRUCTED FORWARD REACH FIGURE 308.2.1 UNOBSTRUCTED HIGH FORWARD REACH FIGURE 308.2.2 (a) 48" MIN. UNOBSTRUCTED HIGH FORWARD REACH FIGURE 308.2.2 (b) 15 " M I N . 48 " M A X . 48" MIN.48" MIN. > 20"-25" MAX. 44 " 48 " M A X . PARALLEL APPROACH FIGURE 303.5 (b) PARALLEL APPROACH FIGURE 305.7 (b) FORWARD APPROACH FIGURE 303.5 (a) CLEAR FLOOR SPACE FIGURE 303.5 FORWARD APPROACH FIGURE 305.7 (a) 60 " M I N . 18" MIN.60 " M I N . 18" MIN. X > 8 " 48 " M I N . NOTE : X = 12" IF DOOR HAS BOTH A CLOSER AND LATCH FRONT APPROACH, PULL SIDE FIGURE 404.2.3.1 (a) RECESSED DOOR FRONT APPROACH, PULL SIDE FIGURE 404.2.3.4 (a) FRONT APPROACH, PUSH SIDE FIGURE 404.2.3.1 (b) RECESSED DOOR FRONT APPROACH, PUSH SIDE FIGURE 404.2.3.4 (b) RECESSED DOOR FRONT APPROACH, PUSH SIDE WITH BOTH CLOSER AND LATCH FIGURE 404.2.3.4 (c) HINGE APPROACH, PULL SIDE FIGURE 404.2.3.1 (c & d) NOTE - X = 36" MIN. IF Y = 60" X = 42" IF Y = 54" X > 8 " 48 " M I N . X > 8 " 48 " M I N . 12" MIN. 42"Y Y = 4 2 " M I N . 22" MIN. Y = 4 8 " M I N . 24" MIN.24" MIN. Y = 4 2 " M I N . NOTE - Y = 48" IF DOOR HAS BOTH A CLOSER AND LATCH NOTE - Y = 54" IF DOOR HAS A CLOSER NOTE - Y = 48" IF DOOR HAS A CLOSER HINGE APPROACH, PUSH SIDE FIGURE 404.2.3.1 (e) LATCH APPROACH, PULL SIDE FIGURE 404.2.3.1 (f) LATCH APPROACH, PUSH SIDE FIGURE 404.2.3.1 (g) POCKET / FOLDING DOOR FRONT APPROACH FIGURE 404.2.3.2 (a) POCKET / FOLDING DOOR POCKET OR HINGE APPROACH FIGURE 404.2.3.2 (b) POCKET / FOLDING DOOR STOP OR LATCH APPROACH FIGURE 404.2.3.2 (c) WITHOUT DOOR FRONT APPROACH FIGURE 404.2.3.3 (a) WITHOUT DOOR SIDE APPOACH FIGURE 404.2.3.3 (b) FIGURE 307.2 LIMITS OF PROTRUDING OBJECTS 1/8" MAX. X > 2 7 " X > 1 5 / 8 " X > 2 7 " - 8 0 " 4" MAX.4" MAX. FIGURE 307.3 POST-MOUNTED PROTRUDING OBJECTS 27 " M A X . X > 12" X > 12" 80 " M I N . 1 4" M A X 1/ 4 " M A X 2 1 FIGURE 303.2 VERTICAL CHANGE IN LEVEL FIGURE 303.3 BEVELED CHANGE IN LEVEL FIGURE 703.3.10 HEIGHT OF RAISED CHARACTERS ABOVE FLOOR 48 " M I N . 60 " M A X . VARIES TACTILE CHARACTERS FIGURE 703.3.11 LOCATION OF SIGNS AT DOORS VARIES - COORD. 18" MIN. 18 " M I N . CLEAR FLOOR SPACE, CENTERED ON TACTILE CHARACTERS 45 ° A-0.1 MANEUVERING CLEARANCES AT DOORS 1/4" = 1'-0" 1 A-0.1 CHANGES IN LEVEL N.T.S. 2 A-0.1 PROTRUDING OBJECTS 1/4" = 1'-0" 3 A-0.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE 1/4" = 1'-0" 5 A-0.1 WHEELCHAIR TURNING 1/4" = 1'-0" 4 A-0.1 CLEAR DOORWAY WIDTH & DEPTH 1/4" = 1'-0" 7 A-0.1 TWO HINGED DOORS IN SERIES 1/4" = 1'-0" 8 A-0.1 FORWARD REACH 1/4" = 1'-0" 10 A-0.1 SIDE REACH 1/4" = 1'-0" 9 A-0.1 MINIMUM CLEAR FLOOR SPACE FOR WHEELCHAIRS 1/4" = 1'-0" 11 A-0.1 ADA SIGNAGE 1/4" = 1'-0" 12 A-0.1 1/4" = 1'-0" 6 COMMUNICATION ELEMENTS AND FEATURES 60" MIN.48 " M I N . DO O R W I D T H 48 " M I N . DO O R W I D T H DO O R W I D T H 48 " M I N 30 " M I N . A-0.1 36" 36" MIN. 24" MIN. 33 " - 3 6 " 17 " - 1 9 " 18 " M I N . 24" MIN. 12" MAX. 18 " M I N . CLEARANCE FOR WATER CLOSET FIGURE 604.3 39"-41" 54" MIN. 42" MAX. 12" MIN. 42" MIN. 39 " - 4 1 " 30 " x 4 8 " 7' - 0 " 56 " M I N . 30 " x 4 8 " WALL HUNG LAVATORY FLOOR MOUNTED TANK-TYPE WATER CLOSET NOTE : 0" X 48" OF CLEAR FLOOR SPACE IS REQUIRED IN EVERY RESTROOM. WHEN 30" X 48" CLEAR FLOOR SPACE IS PROVIDED BEYOND THE ARC OF THE DOOR SWING, THE DOOR IS PERMITTED TO SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. DOOR MAY SWING INTO A REQUIRED WHEELCHAIR TURNING SPACE. PER 2003 ANSI SECTION 603.2.3(2), AN EXCEPTION IS MADE IN SINGLE OCCUPANCY TOILET ROOMS TO ALLOW DOOR TO SWING INTO THE REQUIRED FIXTURE CLEAR FLOOR OR GROUND SPACE \ WHEN ANOTHER CLEAR FLOOR OR GROUND SPACE IS PROVIDED OUTSIDE THE RADIUS OF THE DOOR SWING DIMENSIONS ARE MINIMUM, ACTUAL MAY VARY TUR N I N G R A D I U S 5'-0" M I N . TUR N I N G R A D I U S 48 " M A X . 40 " M A X . 34 " M A X . 29 " M A X . 27 " M A X . 9" M I N . 17" MIN. 8" MIN. 6" MAX. 17" MIN. 6" MIN. 6" MAX. 48 " M A X . 40 " M A X . 34 " M A X . 29 " M A X . 27 " M A X . 9" M I N . FIGURE 606.3 30 " M I N . 17" MIN. 48" MIN. 19" MAX. 30 " M I N . 17" MIN. 48" MIN. 19" MAX. 60" MIN. 56 " M I N . 17"-18"18" MIN. OTHER FIXTURES NOT ALLOWED WITHIN THIS AREA LAV. 33 " - 3 6 " REAR WALL FIGURE 604.5.2 1 1 / 2 " PROTRUDING DISPENSER BELOW GRAB BAR SIDE WALL FIGURE 604.4 FIGURE 604.5.1 FIGURE 604.7 (a) FIGURE 604.11.4 (A) MINIMUM CLEAR DIMENSIONAL REQUIREMENTS - INWARD DOOR SWING 7'-2" 18" MIN.52" 60" MIN. WALL HUNG LAVATORY SHADE AREAS = 30" MIN x 48" MIN. CLEAR SPACE FLOOR MOUNTED TANK-TYPE WATER CLOSET (B) MINIMUM CLEAR DIMENSIONAL REQUIREMENTS - OUTWARD DOOR SWING 7'-2" 18" MIN.52"16"-18" 60" MIN. 6' - 3 " 56 " M I N . 5'-0" M I N . A-0.2 SINGLE OCCUPANT TOILET ROOM 1/4" = 1'-0" 1 A-0.2 LAV. CLEARANCES 1/4" = 1'-0" 2 A-0.2 LAV. CLEAR FLOOR SPACE 1/4" = 1'-0" 3 A-0.2 WATER CLOSET GRAB BARS 1/4" = 1'-0" 6 A-0.2 1/4" = 1'-0" 4 W.C. CLEAR FLOOR SPACE 16"-18" SHADE AREAS = 30" MIN x 48" MIN. CLEAR SPACE KNEE & TOE CLEARANCE FIGURE 306.2 & 306.3 (a) 48" MIN. 30 " M I N . KNEE & TOE CLEARANCE FIGURE 306.2 & 306.3 (b) 11" MIN. 27 " M I N . 8" MIN. 9" M I N . 17"-25" 6" MAX. A-0.2 KNEE & TOE CLEARANCES 1/4" = 1'-0" 5 FIGURE 11B-609.2.2 (a)(b) 4-4.8 perimeter 2 m a x A-0.2 GRAB BAR NON-CIRCULAR CROSS SECT. 1/4" = 1'-0" 7 A-0.2 ACCESSIBLE RESTROOM DOOR SIGNATURE 1/4" = 1'-0" 8 A-0.2 ACCESSIBLE TABLE 1/4" = 1'-0" 9 ACCESSIBILITY DETAILS 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C CONTRAST WITH DOOR COLOR. BACKGROUND COLOR SHALL CONTRAST WITH DOOR COLOR. BACKGROUND COLOR SHALL 60" ABOVE FIN. FLR. (TYP.) THE DOOR AND MOUNTED SHALL BE CENTERED ON AND ADHESIVE. SIGNS SCREWS, COUNTERSUNK THREE FLATHEAD WOOD ATTACH SIGNS USING (3) RADIUS CORNERS, (TYP.) INTERIOR FACE OF CLEAR PAINT BACKGROUND ON PLACTIC BACKING, (TYP.) OPAQUE WHITE ACRYLIC 1/2" WIDE BORDER, (TYP.) NOTE: PLASTIC, (TYP.) CLEAR ACRYLIC PLASTIC, (TYP.) A-0.25 UP 1 1 1 1 1 1 1 7 2 7 7 3 4 4 43 3 4 6 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C EXISTING FLOOR PLAN 1EXISTING FLOOR PLAN 1/4"=1'-0" N KEY NOTES 1 EXISTING COLUMN TO REMAIN 2 EXISTING WALL TO REMAIN 3 EXISTING DOOR TO RAMAIN 4 EXISTING WINDOW TO REMAIN 5 EXISTING STOREFRONT TO REMAIN 6 EXISTING ELECTRICAL PANEL TO REMAIN 7 EXISTING 1 HOUR FIRE RATED WALL TO REMAIN # A-1.0 UP 10 ' - 6 " 13 ' - 7 " 17 ' - 1 1 " 1' - 4 " 61'-5" 46'-1" 11'-3"3'-10"11'-2"3'-9"11'-3"3'-2"10'-10"3'-10" 3' - 8 " 18 ' - 1 0 " 22 ' - 6 " 2' - 0 " 1 3 1 1 22 2 2 2 14'-8" 3 3 3 3 13'-6" 2 4 4 9 5 5 4 6 8 15 15 108 OUTDOOR DINING PATIO 106 ALL GENDER RR 105 ALL GENDER RR 104 STORAGE 101 DINNING AREA 107 KITCHEN AREA 7 8 10 ' - 6 " 6' - 1 " 1'-6" 11 12 13 14 14 12 2 11 17 5 23 ' - 9 " 17'-5"8'-0"8'-0"5'-10"7'-3" 47'-8" 18 ' - 4 " 17 ' - 6 " 3'-5" 12 ' - 0 " 7' - 2 " 5'-6"17'-4" 12 ' - 1 0 " 16'-7" 4' - 2 " 3' - 6 " 9'-10" 5' - 4 " 10'-0" 103 HALLWAY 1'-8" 2'-6" 5 18 5 9 16 6 6 10 15 5 18 18102 SERVICE AREA 18 18 10'-2" 5 2' - 6 " 2'-6" 18 2 2' - 0 " 2' - 0 " 7' - 1 1 " 2' - 7 " 4' - 5 " 8' - 1 1 " 10 " TYPE "A" FLUSH TYPE "B" FLUSH GLASS TYPE "C" FLUSH 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C PROPOSED FLOOR PLAN 1 PROPOSED FLOOR PLAN 1/4"=1'-0" FIRE NOTES 1 THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR PER BUILDING CODE 1006.3 2 WALL, FLOOR AND CEILING FINISHES SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN CBC TABLE 803.11 3 ALL DECORATIVE MATERIALS AND TRIM SHALL COMPLY WITH THE PROVISIONS OF CBC 806 4 THERMAL AND ACOUSTICAL INSULATION SHALL COMPLY WITH CBC 720 DOOR NOTES 1 G.C. SHALL VERIFY EXISTING DOORS AND HARDWARE/RATING AND PROVIDE HARDWARE PER SCHEDULE THAT IS NOT EXISTING 2 THE FLOOR OR LANDING SHALL BE NOT MORE THAN 12" LOWER THAN THE THRESHOLD OF THE DOOR WAY. 3 MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLE TO HINGED DOORS AND AT THE CENTER PLACE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS. 4 ALL SPECIFIED DOOR HARDWARE SHALL BE ACCESSIBLE TO THE PHYSICALLY HANDICAPPED. 5 EGRESS DOOR SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. CBC 1008.1.9 6 WHEN NOT ALL BUILDING ENTRANCES ARE ACCESSIBLE AND USABLE BY PERSONS W/ DISABILITIES SHALL BE IDENTIFIED W/ AT LEAST ONE STANDARD SIGN AND W/ AN ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, TO BE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS. 7 HAND-ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30" AND 44" ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND-ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, BY PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE AS ABOVE IN EGRESS DIRECTION. DOOR SCHEDULE N KEY NOTES 1 EXISTING WALL TO REMAIN 2 EXISTING COLUMN TO REMAIN 3 EXISTING EXTERIOR WINDOW TO REMAIN 4 EXISTING DOOR TO REMAIN 5 NEW 10', 20GA, 16"O.C., 3-5/8" METAL STUD WALL BRACING TO TOP STRUCTURE, SEE A-3.0 6 NEW DOOR, PER DOOR SCHEDULE 7 NEW ADA POS & BAR COUNTER MAX. HEIGHT 34" A.F.F. 8 NEW BAR COUNTER MAX. HEIGHT 42" A.F.F. 9 NEW 1 HOUR FIRE RATED DEMISING WALL PER A-3.0 10 NEW 3' WIDE WALL OPENING 11 NEW INTERNATIONAL SYMBOL OF ACCESSIBILITY, SEE DETAIL 12/A-0.1 12 NEW TACTILE EXIT SIGN W/ BRAILLE 13 MAX. OCCUPANCY SIGN 14 PROVIDE SIGN ABOVE DOOR TO READ "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" 15 NEW EXTERIOR WOOD FENCE FOR PATIO 16 NEW HOOD ABOVE, SEE MECHANICAL PLAN 17 EXISTING CORRIDOR TO PARKING LOT 18 NEW FLOOR SINK # A-1.1 WINDOW NOTES 1 ALL EXTERIOR WINDOWS ARE FIXED AND NOT OPERABLE WALL LEGEND EXISTING WALL TO REMAIN NEW NON-LOAD BEARING PARTITION WALL NEW 1 HOUR FIRE RATED DEMISING WALL LANDLORD NOTE 1 ALL OUTDOOR BENCH SEATING SHALL BE WATERPROOF 2 OUTDOOR DINING AREA SHALL COMPLY WITH SECTION 41-2204, 2205 DOOR SCHEDULE TYPE DOOR SIZE MATERIAL HDW REMARK W H THK DR FRM 1 B 3'-0" PAIR 7'-0"1-3/4"1/4" T.G.ALUM.PANIC EXISTING EXIT DOOR W/ PANIC HDW. @ 40" AFF., 10" KICK PLATE @ BOTTOM, SELF- CLOSING, 32" MINIMUM CLEAR WIDTH. G.C. TO V.I.F. 2 B 3'-0" PAIR 7'-0"1-3/4"1/4" T.G.ALUM.PANIC EXISTING EXIT DOOR W/ PANIC HDW. @ 40" AFF., 10" KICK PLATE @ BOTTOM, SELF- CLOSING, 32" MINIMUM CLEAR WIDTH. G.C. TO V.I.F. 3 A 3'-0"7'-0"1-3/4"H.MTL H.MTL PANIC EXISTING EXIT DOOR W/ PANIC HDW., 40" A.F.F., SELF-CLOSING. G.C. TO V.I.F. 4 A 3'-0"7'-0"1-3/4"H.MTL H.MTL LEVER NEW SWING DOOR W/ LEVER HDW., 40" A.F.F., SELF-CLOSING 5 A 3'-0"7'-0"1-3/4"H.MTL H.MTL LEVER NEW SWING DOOR W/ LEVER HDW., 40" A.F.F., SELF-CLOSING 6 C 3'-0"7'-0"1-3/4"H.MTL H.MTL LEVER NEW SWING DOOR W/ VISION WINDOW BOTTOM @ 43" MAX. A.F.F., SELF-CLOSING PLUMBING OL CALCULATION FUNCTION AREA FACTOR OL INDOOR DINING 784 SF 30 26 SERVICE AREA 250 SF 50 5 KITCHEN 335 SF 50 7 OUTDOOR DINING 348 SF 30 11 TOTAL 49 PLUMBING FIXTURE CALCULATION WC LAV URINAL MEN (24.5 OL)1 1 1 PROVIDED 1 1 1 WOMEN (24.5 OL)1 1 PROVIDED 1 1 5 UP 18x36 5 TIER 18x60 5 TIER 18 x 2 4 5 T I E R A.03 18x54 5 TIER 18 x 3 6 5 T I E R 18 x 3 6 5 T I E R 2 A-2.0 MAX. 5% RUNNING SLOPE & 2% CROSS SLOPE MAX. 5% RUNNING SLOPE & 2% CROSS SLOPE MAX. 5% RUNNING SLOPE & 2% CROSS SLOPE 108 OUTDOOR DINING PATIO 106 ALL GENDER RR 105 ALL GENDER RR 104 STORAGE 101 DINNING AREA 107 KITCHEN AREA 103 HALLWAY 102 SERVICE AREA 3' - 1 0 " 3'-4"6'-7" 14 ' - 9 " 7'-9" 15 ' - 5 " 10'-2"10'-8"18'-2"12'-6" 18 ' - 5 " 16'-11" 7' - 2 " 4' - 1 " 14 ' - 5 " 9' - 1 0 " 3' - 0 " 3'-0"3'-5" RESTROOM ACCESS SIGN SEE DETAIL 8/ A-0.2, TYP. 3'-0" 8'-1" 106 ALL GENDER RR 105 ALL GENDER RR 1'-6"1'-6"3'-0" 8'-0" 3' - 6 " 10 ' - 7 " 3'-1" 3' - 6 " 8' - 6 " 4' - 0 " 13'-4" 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C EGRESS & ENLARGED RESTROOM PLAN 1EGRESS PLAN 1/4"=1'-0" N FIRE NOTES 1 THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR PER BUILDING CODE 1006.3 2 WALL, FLOOR AND CEILING FINISHES SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN CBC TABLE 803.11 3 ALL DECORATIVE MATERIALS AND TRIM SHALL COMPLY WITH THE PROVISIONS OF CBC 806 4 THERMAL AND ACOUSTICAL INSULATION SHALL COMPLY WITH CBC 720 ACCESSIBLE SEATING CALCULATION REGULAR ADA TOTAL % TABLE SEATING 19 1 20 5% BAR SEATING 12 1 13 7.7% OUTDOOR SEATING 11 1 12 8.3% TOTAL SEATING 53 2ENLARGED RESTROOM FLOOR PLAN 1/2"=1'-0" SIGNAGE NOTES 1 DIRECTIONAL SIGN VISUAL CHARACTER SHALL BE 40 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. (11B-216.3, 11B-216.6, 11B-703.5.6) 2 WHERE BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED, EITHER ON SIGN WITH BOTH VISUAL AND TACTILE CHARACTERS, OR TWO SEPARATE SIGNS, ONE WITH VISUAL, AND ONE WITH TACTILE CHARACTERS, SHALL BE PROVIDED. (11B-703.1) 3 WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONG THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT AND DOORS. SIGNS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE 18x18 INCHES MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING. (11B-703.4.2) (FIGURE 11B-703.4.1) 4 TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48" MINIMUM ABOVE FINISH FLOOR, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60" MAXIMUM ABOVE FINISH FLOOR, MEASURED FROM THE BASE LINE OF THE HIGHEST LINE OF THE RAISED CHARACTERS. (11B-703.4.1) (FIGURE 11B-703.4.1) 5 CORRESPONDING BRAILLE SHALL BE LOCATED BELOW CHARACTERS, 3/8" - 1/2", CENTERED OR FLUSH LEFT. (11B-216, 11B-216.2) 6 WHEN SIGNS IDENTIFY PERMANENT ROOMS AND SPACES OF A BUILDING OR SITE, THEY SHALL COMPLY WITH CBC 11B-703.1; 11B-703.2; 11B-703.3 AND 11B-703.5. WHERE PICTOGRAMS ARE PROVIDED, IT SHALL COMPLY WITH SECTION 11B-703.6 AND SHALL HAVE TEXT DESCRIPTIONS COMPLYING WITH SECTIONS 11B-703.2 & 11B-703.5. (11B-216.2) N A-2.0 5 5 UP C-02 5 8'-0" C-01 1 C-04 10'-0" 2 C-02 5 8'-0" C-01 1 4 108 OUTDOOR DINING PATIO 106 ALL GENDER RR 105 ALL GENDER RR 104 STORAGE 101 DINNING AREA 107 KITCHEN AREA 103 HALLWAY 102 SERVICE AREA C-04 10'-0" 2 C-03 3 10'-0" C-05 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C 1PROPOSED CEILING PLAN 1/4"=1'-0" FINISH NOTES 1 INTERIOR FINISH COMPLIANCE W/ CBC 803.1 FLAME SPREAD PROVISIONS AND WALL AND CEILING SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATION IN CBC TABLE 803.9 (CLASS A FOR EXIT ENCLOSURES, EXIT PASSAGE WAYS AND CORRIDORS - CLASS B FOR ROOMS AND ENCLOSED SPACES). 2 INTERIOR FLOOR FINISHS SHALL COMPLY WITH CBC 804.1 AND CLASS II. 3 ALL FLOOR, WALLS AND CEILINGS SHALL BE SMOOTH, DURABLE, NON-ABSORTBENT, AND EASILY CLEANABLE (GLOSS OR SEMI-GLOSS). COVE BASE TILE SHALL BE OF MINIMUM 3/8" RADIUS AND MINIMUM 4" HIGH TILE CEILING LEGEND EMERGENCY EXIT SIGN (MIN. 90 MINS BACK UP BATTERY) EMERGENCY LIGHTING FIXTURE (MIN. 90 MINS BACK UP BATTERY) 6" RECESSED CAN LIGHTING FIXTURE LED PENDENT LIGHTING FIXTURE 2x4 LAY-IN LED LIGHTING FIXTURE X'-X"CEILING HEIGHT INDICATION FINISH DESIGNATIONS. REFER TO FINISH SCHEDULEXX-XX PROPOSED CEILING PLAN KEY NOTES 1 EXISTING OPEN CEILING 2 NEW SUSPENDED T-BAR CEILING, WHITE COLOR. 10'-0" A.F.F. 3 NEW SUSPENDED GYP. BD. CEILING, WHITE COLOR. 10'-0" A.F.F. 4 NEW HOOD ABOVE W/ 16 GAGE STAINLESS STEEL PANEL ON THE WALL BEHIND 5 NEW GYP. BD. CEILING, WHITE COLOR. 8'-0" A.F.F. # A-2.1N FINISH AND CEILING SCHEDULE NAME TAG ITEM MANUFACTURER PRODUCT FINISH LOCATION COLOR/DECRIPTION C-01 OPEN CEILING & EXPOSED DUCT --- ------DINING, HALLWAY PAINT DUCTS TO WHITE C-02 GYP. BD. CEILING ------ ---RESTROOM WHITE & SMOOTH, NO TEXTURE, SEMI-GLOSS C-03 SUSPENDED GYP. BD. CEILING USG ENSEMBLE DRYWALL CEILING ---SERVICE WHITE & SMOOTH, NO TEXTURE, SEMI-GLOSS C-04 SUSPENDED T-BAR CEILING USG SHEETROCK BRAND CLEAN ROOM ---KITCHEN & STORAGE WHITE & SMOOTH, NO TEXTURE, SEMI-GLOSS C-05 EXHAUST HOOD --- --- ---KITCHEN KITCHEN EXHAUST HOOD RE: MECH.DWGS. F-01 SEALED CONCRETE GLAZE N' SEAL MULTI-PURPOSE SEALER ---ALL AREAS #536, GRAY F-02 STAINED CONCRETE NEWLOOK --- ---PATIO COLOR: DARK BROWN; FADERESISTANT CEMENT COLOR;0.50LB; POWDERED OXIDEADDITIVE B-01 SLIM FOOT COVE BASE DALTILE S-3619TN ---ALL AREAS 4" HIGH W/ 3/8" RADIUS, WHITE W-01 PAINT ------ --- DINING, HALLWAY, RESTROOM WHITE, SEMI-GLOSS W-02 FRP ---------KITCHEN & STORAGE WHITE W-03 CERAMIC TILE ---------SERVICE & RESTROOM WHITE M-01 MILLWORK --------- FRONT BAR COUNTER QT-01 QUARTZ TOP --- --- --- FRONT BAR COUNTER WHITE & GRAY SS-01 STAINLESS STEEL --- --- --- BEHIND HOOD STAINLESS STEEL PANEL UP B-01 W-01 W-01 W-01 W-01 B-01 W-01 QT-01 M-01 B-01 B-01 W-03 B-01 W-02 B-01 W-01 F-01 5 F-01 5 F-01 5 F-02 6 B-01 W-01 108 OUTDOOR DINING PATIO 106 ALL GENDER RR 105 ALL GENDER RR 104 STORAGE 101 DINNING AREA 107 KITCHEN AREA 103 HALLWAY 102 SERVICE AREA B-01 W-02 B-01 W-01 F-01 5 F-01 5 B-01 F-01 5 QT-01 M-01 B-01 B-01 W-01 B- 0 1 F-01 B-01 W-03 B-01 B-01 W-03 B-01 W-02 W-02 W-02 7 7 B-01 QT-01 M-01 B-01 B-01 W-01 B-01 W-02 B-01 W-02 B-01 W-02 B-01 SS-01 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C PROPOSED FINISH PLAN 1PROPOSED FINISH PLAN 1/4"=1'-0" N A-2.2 FINISH NOTES 1 INTERIOR FINISH COMPLIANCE W/ CBC 803.1 FLAME SPREAD PROVISIONS AND WALL AND CEILING SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATION IN CBC TABLE 803.9 (CLASS A FOR EXIT ENCLOSURES, EXIT PASSAGE WAYS AND CORRIDORS - CLASS B FOR ROOMS AND ENCLOSED SPACES). 2 INTERIOR FLOOR FINISHS SHALL COMPLY WITH CBC 804.1 AND CLASS II. 3 ALL FLOOR, WALLS AND CEILINGS SHALL BE SMOOTH, DURABLE, NON-ABSORTBENT, AND EASILY CLEANABLE (GLOSS OR SEMI-GLOSS). COVE BASE TILE SHALL BE OF MINIMUM 3/8" RADIUS AND MINIMUM 4" HIGH TILE FINISH AND CEILING SCHEDULE NAME TAG ITEM MANUFACTURER PRODUCT FINISH LOCATION COLOR/DECRIPTION C-01 OPEN CEILING & EXPOSED DUCT --- ------DINING, HALLWAY PAINT DUCTS TO WHITE C-02 GYP. BD. CEILING ------ ---RESTROOM WHITE & SMOOTH, NO TEXTURE, SEMI-GLOSS C-03 SUSPENDED GYP. BD. CEILING USG ENSEMBLE DRYWALL CEILING ---SERVICE WHITE & SMOOTH, NO TEXTURE, SEMI-GLOSS C-04 SUSPENDED T-BAR CEILING USG SHEETROCK BRAND CLEAN ROOM ---KITCHEN & STORAGE WHITE & SMOOTH, NO TEXTURE, SEMI-GLOSS C-05 EXHAUST HOOD --- --- ---KITCHEN KITCHEN EXHAUST HOOD RE: MECH.DWGS. F-01 SEALED CONCRETE GLAZE N' SEAL MULTI-PURPOSE SEALER ---ALL AREAS #536, GRAY F-02 STAINED CONCRETE NEWLOOK --- ---PATIO COLOR: DARK BROWN; FADERESISTANT CEMENT COLOR;0.50LB; POWDERED OXIDEADDITIVE B-01 SLIM FOOT COVE BASE DALTILE S-3619TN ---ALL AREAS 4" HIGH W/ 3/8" RADIUS, WHITE W-01 PAINT ------ --- DINING, HALLWAY, RESTROOM WHITE, SEMI-GLOSS W-02 FRP ---------KITCHEN & STORAGE WHITE W-03 CERAMIC TILE ---------SERVICE & RESTROOM WHITE M-01 MILLWORK --------- FRONT BAR COUNTER QT-01 QUARTZ TOP --- --- --- FRONT BAR COUNTER WHITE & GRAY SS-01 STAINLESS STEEL --- --- --- BEHIND HOOD STAINLESS STEEL PANEL KEY NOTES 1 EXISTING OPEN CEILING 2 NEW GYP. BD. CEILING, WHITE COLOR 3 36" WIDE SOFFIT 8'-0" A.F.F. 4 NEW HOOD ABOVE W/ 16 GAGE STAINLESS STEEL PANEL ON THE WALL BEHIND 5 SEALED CONCRETE THROUGHOUT. USE SLIM FOOT SANITARY TILE COVE BASE, MIN. 4" HIGH W/ 3/8" RADIUS 6 STAINED CONCRETE THROUGHOUT AT PATIO 7 CERAMIC TILE UP TO 4' ABOVE FINISH FLOOR # DETAILS 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C TYP. WALL BOTTOM TO FLOOR SCALE:1NONE TYP. STUD CORNER TIE SCALE:2NONE TYP. JAMB STUD SCALE:3NONE TYP. STUD TOP TRACK SCALE:4NONE 1 HOUR FIRE RATED WALL SCALE:5NONE TYP. JOIST TO BACKING SCALE:6NONE TYP. JOISTS ON STUD WALL SCALE:7NONE TYP. BOX HEADER ON STUD WALL SCALE:8NONE TYP. BLOCKING CONNECTION SCALE:9NONE TYP. STUD WALL BRACING SCALE:11NONE TYP. STUD LATERAL BRACING SCALE:12NONE SCALE:14NONE SCALE:15NONENOT USED NOT USED SCALE:20NONE NOT USED SCALE:21NONE NOT USED SCALE: NONE NOT USED SCALE:23NONE TYP. DOOR HEADER SCALE:10NONE SCALE:13NONE 1 22 GYP. BD. CEILING SCALE:16NONE SCALE:17NONE SCALE:19NONE 1 MAX. 1 NOT USED SCALE:18NONE NOT USED NOT USED CEILING JOIST TO CONCRETE NOT USED A-3.0 1HEAVY DUTY SUSPENDED CEILING TYPICAL DETAILS 1.GENERAL REQUIREMENTS: THE FOLLOWING REQUIREMENTS APPLY TO CEILING SYSTEMS WHOSE TOTAL WEIGHT, INCLUDING CEILING MOUNTED AIR TERMINALS, SERVICES AND LIGHT FIXTURES, DOES NOT EXCEED FOUR (4) PSF. HEAVIER SYSTEMS, AND THOSE SUPPORTING LATERAL LOADS FROM PARTITIONS, WILL REQUIRE SPECIAL DESIGN DETAILS. 1.1 #12 GAGE WIRE SHALL BE 0.106 INCHES IN DIAMETER CONFORMING TO ASTM A641. #12 GAGE WIRE SHALL BE SOFT ANNEALED, GALVANIZED STEEL WIRE WITH A CLASS 1 COATING. 1.2 #12 GAGE HANGER WIRES MAY BE USED FOR UP TO AND INCLUDING 4 FT. BY 4 FT. GRID SPACING AND SHALL BE ATTACHED TO MAIN RUNNERS. 1.3 PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN EIGHT (8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE END TEE, WHICHEVER IS LEAST, FOR THE PERIMETER OF THE CEILING AREA. SEE DETAIL 8/A913. PERIMETER WIRES ARE NOT REQUIRED WHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS. 1.4 PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO TYPICAL HANGER SPACING. SEE DET 9/A914. PROVIDE ADDITIONAL HANGERS, STRUTS OR BRACES AS REQUIRED AT ALL CEILING BREAKS, SOFFITS, OR DISCONTINUOUS AREAS. HANGER WIRES THAT ARE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB ARE TO HAVE COUNTER-SLOPING WIRES. 1.5 CEILING GRID MEMBERS SHALL BE ATTACHED TO TWO (2) ADJACENT WALLS PER ASCE 7-05, SECTION 13.5.6.2(B). CEILING GRID MEMBERS SHALL BE AT LEAST 3/4 INCH CLEAR OF OTHER WALLS. IF WALLS RUN DIAGONALLY TO CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN AND CROSS RUNNERS SHOULD BE FREE, AND A MINIMUM OF 3/4 INCH CLEAR OF WALL. 1.6 THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN 2 INCHES. 1.7 AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS ARE NOT CONNECTED TO THE ADJACENT WALL, PROVIDE INTERCONNECTION BETWEEN THE RUNNERS AT THE FREE END TO PREVENT LATERAL SPREADING. A METAL STRUT OR A #16 GAGE WIRE WITH A POSITIVE MECHANICAL CONNECTION TO THE RUNNER MAY BE USED. WHERE THE PERPENDICULAR DISTANCE FROM THE WALL TO THE FIRST PARALLEL RUNNER IS 8 INCHES OR LESS, THIS INTERLOCK IS NOT REQUIRED. 1.8 EXPANSION JOINTS SHALL BE PROVIDED IN THE CEILING AT INTERSECTIONS OF CORRIDORS AND AT JUNCTIONS OF CORRIDORS WITH LOBBIES OR OTHER SIMILAR AREAS. 1.9 PROVIDE LATERAL-FORCE BRACING ASSEMBLIES CONSISTING OF A COMPRESSION STRUT AND FOUR (4) #12 GAGE SPLAYED BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER (SEE DETAIL 5 / A913). 1.10 PROVIDE BRACING ASSEMBLIES AT LOCATIONS NOT MORE THAN ONE HALF (1/2) THE CALCULATED SPACING IN EACH DIRECTION FROM EACH PERIMETER WALL AND AT THE EDGES OF ANY CHANGE IN ELEVATION OF THE CEILING. 1.11 THE SLOPE OF BRACING WIRES SHALL NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING AND WIRES SHALL BE TAUT. SPLICES IN WIRES ARE NOT PERMITTED WITHOUT SPECIAL DSA APPROVAL. 1.12 COMPRESSION STRUTS SHALL NOT BE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB. 1.13 SUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING AREA OF 144 SQUARE FEET OR LESS, AND FIRE RATED SUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING AREA OF 96 SQUARE FEET OR LESS, SURROUNDED BY WALLS WHICH CONNECT DIRECTLY TO THE STRUCTURE ABOVE OR WALLS INDEPENDENTLY BRACED ABOVE CEILING TO STRUCTURE ABOVE, DO NOT REQUIRE BRACING ASSEMBLIES WHEN ATTACHED TO TWO ADJACENT WALLS. 1.14 FOR CEILING AREAS EXCEEDING 2500 SQUARE FEET A SEISMIC SEPARATION JOINT SHALL BE PROVIDED TO DIVIDE THE CEILING INTO AREAS NOT EXCEEDING 2500 SQUARE FEET. ALTERNATIVELY, STRUCTURAL ANALYSIS SHALL BE PERFORMED TO DEMONSTRATE COMPLIANCE WITH ASTM E580-08 SECTION 5.2.9. 1.15 PENETRATIONS THROUGH THE CEILING FOR SPRINKLER HEADS AND OTHER SIMILAR DEVICES THAT ARE NOT INTEGRALLY TIED TO THE CEILING SYSTEM IN THE LATERAL DIRECTION SHALL HAVE A TWO (2) INCH OVERSIZED RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF ONE (1) INCH IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, PER ASTM E580 SECTION 5.2.8.8, A FLEXIBLE SPRINKLER HOSE FITTING THAT CAN ACCOMMODATE 1 INCH OF CEILING MOVEMENT SHALL BE PERMITTED TO BE USED IN LIE OF THE OVERSIZED RING, SLEEVE OR ADAPTER. 1.16 FASTEN #12 HANGER WIRES WITH NOT LESS THAN THREE (3) TIGHT TURNS IN 3 INCHES. HANGER WIRE LOOPS SHALL BE TIGHTLY WRAPPED AND SHARPLY BENT TO PREVENT ANY VERTICAL MOVEMENT OR ROTATION OF THE MEMBER WITHIN THE LOOPS (SEE ASTM E580, SECTION 5.2.7.2).FASTEN #10 OR #12 BRACING WIRES WITH FOUR (4) TIGHT TURNS. MAKE ALL TIGHT TURNS WITHIN A DISTANCE OF 1-1/2 INCHES. HANGER OR BRACING WIRE ANCHORS TO THE STRUCTURE SHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE ANCHOR ALIGNS AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE WIRE. NOTE: WIRE TURNS MADE BY MACHINE WHERE BOTH STRANDS HAVE BEEN DEFORMED OR BENT IN WRAPPING CAN WAIVE THE 1-1/2 INCH REQUIREMENT, BUT THE NUMBER OF TURNS SHOULD BE MAINTAINED, AND BE AS TIGHT AS POSSIBLE. 1.17 SEPARATE ALL CEILING HANGER AND BRACING WIRES AT LEAST SIX (6) INCHES FROM ALL UNBRACED DUCTS, PIPES, CONDUIT, ETC. 1.18 WHEN DRILLED-IN CONCRETE ANCHORS OR SHOT-IN ANCHORS ARE USED IN REINFORCED CONCRETE FOR HANGER WIRES, 1 OUT OF 10 WIRE/ANCHOR ASSEMBLIES MUST BE FIELD TESTED FOR 200 LBS. IN TENSION. WHEN DRILLED-IN CONCRETE ANCHORS ARE USED FOR BRACING WIRES, 1 OUT OF 2 WIRE/ANCHOR ASSEMBLIES MUST BE FIELD TESTED FOR 440 LBS. IN TENSION IN THE DIRECTION OF THE WIRE. SHOT-IN ANCHORS IN CONCRETE ARE NOT PERMITTED FOR BRACING WIRES. NOTE: DRILLED-IN OR SHOT-IN ANCHORS REQUIRE SPECIAL DSA APPROVAL PRIOR TO USE IN PRESTRESSED CONCRETE. 1.19 ATTACH ALL LIGHT FIXTURES AND CEILING MOUNTED AIR TERMINALS, TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. SCREWS OR APPROVED FASTENERS ARE REQUIRED. 1.20 FLUSH OR RECESSED LIGHT FIXTURES, WEIGHING LESS THAN 56 LBS. AND MECHANICAL TERMINALS AND SERVICES, WEIGHING LESS THAN 20 LBS., MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY DUTY GRID SYSTEM BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF TWO (2) #12 GAGE SLACK SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THE STRUCTURE ABOVE. ALL 4 FT. X 4 FT. LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRES AT EACH CORNER. ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING 56 LBS. OR MORE AND MECHANICAL TERMINALS AND SERVICES, WEIGHING 20 LBS. OR MORE, MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR (4) TAUT #12 GAGE WIRES, EACH ATTACHED TO THE FIXTURE AND TO THE STRUCTURE ABOVE. THE FOUR (4) TAUT #12 GAGE WIRES, INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE, MUST BE CAPABLE OF SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE UNIT. FLUSH OR RECESSED LIGHT FIXTURES, WEIGHING LESS THAN 56 LBS. AND MECHANICAL TERMINALS AND SERVICES, WEIGHING LESS THAN 20 LBS., MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY DUTY GRID SYSTEM BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF TWO (2) #12 GAGE SLACK SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THE STRUCTURE ABOVE. ALL 4 FT. X 4 FT. LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRES AT EACH CORNER. 1.21 SUPPORT SURFACE MOUNTED LIGHT FIXTURES BY AT LEAST TWO POSITIVE DEVICES WHICH SURROUND THE CEILING RUNNER AND WHICH ARE EACH SUPPORTED FROM THE STRUCTURE ABOVE BY A #12 GAGE WIRE. SPRING CLIPS OR CLAMPS THAT CONNECT ONLY TO THE RUNNER ARE NOT ACCEPTABLE. PROVIDE ADDITIONAL SUPPORTS WHEN LIGHT FIXTURES ARE 8 FT. OR LONGER. MAXIMUM SPACING BETWEEN SUPPORTS SHALL NOT EXCEED 8 FEET. 1.22 SUPPORT PENDANT MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRUCTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF SUPPORTING TWO (2) TIMES THE WEIGHT OF THE FIXTURE. A BRACING ASSEMBLY, PER DETAIL 5 / A913, IS REQUIRED WHERE THE PENDANT HANGER PENETRATES THE CEILING. SPECIAL DETAILS ARE REQUIRED TO ATTACH THE PENDANT HANGER TO THE BRACING ASSEMBLY TO TRANSMIT HORIZONTAL FORCE. IF THE PENDANT MOUNTED LIGHT FIXTURE IS DIRECTLY AND INDEPENDENTLY BRACED BELOW THE CEILING, I.E. AIRCRAFT CABLES TO WALLS, THEN BRACE ASSEMBLY IS NOT REQUIRED ABOVE THE CEILING. SEE IR 16-9 FOR ADDITIONAL REQUIREMENT FOR PENDENT MOUNTED FIXTURES. 1.23 THE CEILING GRID SYSTEM MUST BE RATED AS HEAVY DUTY AS DEFINED BY ASTM C635. 1.24 METAL PANELS AND PANELS WEIGHING MORE THAN 1/2 PSF, OTHER THAN MINERAL FIBER ACOUSTICAL TILE, ARE TO BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION RUNNERS. 1.25 ALL LIGHT-WEIGHT MISCELLANEOUS DEVICES, SUCH AS STROBE LIGHTS, SPEAKERS, ETC., SHALL BE ATTACHED TO THE CEILING GRID PER SECTION 7.1 OF IR. IN ADDITION, DEVICES WEIGHING MORE THAN 10 LBS SHALL HAVE A #12 SLACK SAFETY WIRE ANCHORED TO THE STRUCTURE ABOVE. DEVICES WEIGHING MORE THAT 20 LBS SHALL BE SUPPORTED FROM THE STRUCTURE ABOVE METAL SUSPENSION SYSTEMS FOR LAY-IN PANEL CEILINGS ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING 56 LBS. OR MORE AND MECHANICAL TERMINALS AND SERVICES, WEIGHING 20 LBS. OR MORE, MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR (4) TAUT #12 GAGE WIRES, EACH ATTACHED TO THE FIXTURE AND TO THE STRUCTURE ABOVE. THE FOUR (4) TAUT #12 GAGE WIRES, INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE, MUST BE CAPABLE OF SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE UNIT. 12 GA. HANGER WIRE, 3 TIGHT TURNS. 10 OR 12 GA. BRACING WIRE; 4 TIGHT TURNS AT BOTH ENDS OF WIRE, TYPICAL 12 GAUGE WIRE, TYPICAL - 12 GA. WIRE SHALL BE 0.106 INCHES IN DIAMETER CONFORMING TO ASTM A641. 12 GA. WIRE SHALL BE SOFT ANNEALED, GALVANIZED STEEL WIRE WITH A CLASS 1 COATING. NOTE: HANGER OR BRACING WIRE ANCHORS TO THE STRUCTURE AND SHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE ANCHOR ALIGNS AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE WIRE. COMPRESSION STRUT CROSS RUNNER (4) 12 GA. BRACING WIRE AT EA. COMPRESSION STRUT W/ MIN. 4 TIGHT TURNS IN 1-1/2" BOTH ENDS OF WIRE CONNECT TO MAIN RUNNER 12 GA. VERTICAL HANGER WIRE AT 4'-0" EACH WAY (4' OC. AT MAIN RUNNER) MINIMUM 3 TIGHT TURNS IN 1 1/2" BOTH ENDS (TYPICAL) 2" (MAX) FROM BRACING WIRES TO COMPRESSION STRUT AND CROSS RUNNER COMPRESSION STRUTS: COMPRESSION STRUTS SHALL NOT REPLACE HANGER WIRES. MAXIMUM KL/R RATIO OF 200 OR LESS. ATTACH COMPRESSION STRUTS TO MAIN RUNNERS WITHIN TWO (2) INCHES OF CROSS RUNNER. THE ATTACHMENT AT THE TOP SHALL BE CAPABLE OF SUPPORTING FOUR TIMES THE WEIGHT OF THE STRUT. MAIN RUNNER WALL SLIP 2" LEDGER ANGLE 2" STANDARD LEDGER ANGLE- CONNECT TO STRUCTURE, NOT FINISH RUNNER SPLICE POP RIVET TYP. HANGER WIRE AT 4'-0" WITH ONE PAIR OF BRACING WIRES PARALLEL TO WALL AT 12'-0" O.C. SEE SECTIONS 1.9, 1.10 AND 1.11 TYPICAL HANGER WIRE POP RIVET CONNECTED WALLCROSS RUNNER OR MAIN RUNNER HANGER WIRE, TYP. #12 GAUGE MIN.HANGER WIRE @ 48" O.C. MAX.EACH WAY (MAXIMUM 16 SQUARE FEET SUPPORTED AREA) OR METAL STUD COMPRESSION STRUT, ATTACHED TO STRUCTURE ABOVE; PROVIDE STRUT AT EACH BRACING ASSEMBLY, TYPICAL. SCHEMATIC SUSPENDED LAY-IN PANEL CEILING FRAMING PLAN BRACING ASSEMBLY PER A-3.1 ATTACHED (OR FIXED) EDGE FREE EDGE FR E E E D G E AT T A C H E D ( O R F I X E D ) E D G E B A-3.1 A A-3.1 A A-3.1 B A-3.1 MAIN RUNNERS CR O S S RU N N E R S SCHEMATIC SECTION METAL T GRID SUSPENSION SYSTEM ACOUSTIC TILE BLOCKING BETWEEN STUDS METAL STUD COMPRESSION STRUT, ATTACH TO STRUCTURE ABOVE; PROVIDE STRUT AT EACH BRACING ASSEMBLY PER A-3.2 INTERIOR STUD WALL PER PLAN AND WALL SCHEDULE A-3.1 A/B 6" M A X . CROSS METAL RUNNER MAIN METAL RUNNER SUSPENDED LIGHT FIXTURE ATTACHED TO CEILING GRID TO RESIST HORIZONTAL FORCE EQUAL TO WEIGHT OF FIXTURE WITH SCREWS #12 STEEL WIRE HANGERS, ATTACH TO PERMANENT STRUCTURE, TYPICAL 6 PLACES A B DETAILS 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C A-3.1 UP DN UP LOBBY UPUP DN UP FD FD FD ADAD FEC FEC 1 3 11 10 E 4TH STREET 10 2 5 2 2 12 4 9 86 6 77 5 99 10 10 5 N B U S H S T 10 VANCANT TENANT SPACE B OCCUPANCY 13 14 14 2' - 0 " 3' - 0 " 79'-1" 12 12 12 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C SITE PLAN 1SITE PLAN 1/8"=1'-0" N KEY NOTES 1 PROJECT LOCATION 2 EXISTING STREET PARKING 3 EXISTING PARKING GARAGE 4 EXISTING ADA CURB RAMP, MAX. 1:20 (5%) RUNNING SLOPE & 1:50 (2%) CROSS SLOPE 5 PATH OF TRAVEL TO MAIN ENTRANCE FROM PUBLIC SIDEWALK, MAX. 1:20 (5%) RUNNING SLOPE & 1:50 (2%) CROSS SLOPE 6 EXISTING SIDEWALK 7 EXISTING 6" CURB 8 EXISTING PUPLIC TRASH CAN 9 EXISTING STREET LIGHT 10 EXISTING TREE 11 EXISTING PROPERTY LINE 12 EXISTING FIRE HYDRANT 13 EXISTING DUMPSTER 14 EXISTING EGRESS THROUGH CORRIDOR TO PARKING IN THE BUILDING 15 NEW PLANTER BARRIER AROUND OUTDOOR DINING PATIO SP-1.0 UP DN UP LOBBY UPUP DN UP FD FD FD ADAD FEC FEC 1 3 11 10 E 4TH STREET 10 2 5 2 2 12 4 9 86 6 77 5 99 10 10 5 N B U S H S T 10 VANCANT TENANT SPACE B OCCUPANCY 13 14 14 2' - 0 " 3' - 0 " 79'-1" 12 12 12 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C 2N D B U I L D I N G P C 4T H H E A L T H P C 12 - 1 5 - 2 5 11 - 7 - 2 5 SITE PLAN 1SITE PLAN 1/8"=1'-0" N KEY NOTES 1 PROJECT LOCATION 2 EXISTING STREET PARKING 3 EXISTING PARKING GARAGE 4 EXISTING ADA CURB RAMP, MAX. 1:20 (5%) RUNNING SLOPE & 1:50 (2%) CROSS SLOPE 5 PATH OF TRAVEL TO MAIN ENTRANCE FROM PUBLIC SIDEWALK, MAX. 1:20 (5%) RUNNING SLOPE & 1:50 (2%) CROSS SLOPE 6 EXISTING SIDEWALK 7 EXISTING 6" CURB 8 EXISTING PUPLIC TRASH CAN 9 EXISTING STREET LIGHT 10 EXISTING TREE 11 EXISTING PROPERTY LINE 12 EXISTING FIRE HYDRANT 13 EXISTING DUMPSTER 14 EXISTING EGRESS THROUGH CORRIDOR TO PARKING IN THE BUILDING 15 NEW PLANTER BARRIER AROUND OUTDOOR DINING PATIO SP-1.0 ACCESSIBLE NOTE ACCESSIBLE ROUTE FROM ACCESSIBLE PARKING TO THE ENTRANCE IS IN FULL COMPLIANCE WITH 11B OF 2022 CBC 5 TITLE24 - INDOOR RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 2:43:03 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 N.T.S. TE00 TITLE24 - INDOOR J.L.K.P. 109 E 4TH ST., SANTA ANA, CA 92701 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 109 E 4TH ST., SANTA ANA, CA 92701 109 E 4TH ST., SANTA ANA, CA 92701 109 E 4TH ST., SANTA ANA, CA 92701 109 E 4TH ST., SANTA ANA, CA 92701 109 E 4TH ST., SANTA ANA, CA 92701109 E 4TH ST., SANTA ANA, CA 92701 109 E 4TH ST., SANTA ANA, CA 92701 949-533-4117 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 949-533-4117 E24049 10/24/2025 10/24/2025 MECHANICAL TITLE 24 - 1 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:42:13 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 TM00 MECHANICAL TITLE 24 - 1 D.L.R.C. 109 E 4TH ST., SANTA ANA, CA 92701 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 M40915 10/24/2025 10/24/2025 109 E 4TH ST., SANTA ANA, CA 92701 MECHANICAL TITLE 24 - 2 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:42:14 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 TM01 MECHANICAL TITLE 24 - 2 D.L.R.C. 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 M40915 10/24/2025 10/24/2025 109 E 4TH ST., SANTA ANA, CA 92701 TITLE 24 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 12/2/2025 12:13:16 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 PL A N C H E C K R E V . 1 2 / 0 2 / 2 0 2 5 TP00 E.H.D.T. TITLE 24 N.T.S. 109 E 4TH ST. 10/24/2025 109 E 4TH ST.109 E 4TH ST. 109 E 4TH ST.109 E 4TH ST. 109 E 4TH ST.109 E 4TH ST. 109 E 4TH ST. 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 949-533-4117 M42581 10/24/2025 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 949-533-4117 EDDIE HO EDDIE HO 4 ·NEW RESTAURANT. ·PROVIDE NEW LIGHTING FIXTURES/CONNECTIONS THROUGHOUT THE SPACE. ·PROVIDE NEW POWER FIXTURES/CONNECTIONS THROUGHOUT THE SPACE. ·EXISTING MAIN SERVICE/METER EQUIPMENT AND INSTALLATION OF NEW DISTRIBUTION EQUIPMENT. SHEET INDEX E000 E001 E100 E200 E201 TE00 ELECTRICAL SPECIFICATIONS (AS APPLICABLE) ELECTRICAL SPECIFICATION SINGLE LINE DIAGRAM/ SCHEDULES LIGHTING PLAN POWER PLAN POWER PLAN - ROOF TITLE24 - INDOOR 5.UNLESS OTHERWISE NOTED ON DRAWINGS OR OTHERWISE REQUIRED BY THE NATIONAL ELECTRICAL CODE, HANDICAP CODES OR LOCAL CODES, OUTLET HEIGHTS SHALL BE AS FOLLOWS: 3. 4. 6. 7. 5. 8. 9. 10. 120/208 VOLT SYSTEM NEUTRAL - WHITE PHASE A OR L1 - BLACK PHASE B OR L2 - RED PHASE C OR L3 - BLUE GROUND - GREEN FINAL CONNECTIONS INTO AND OUT OF THE TRANSFORMER. FINAL CONNECTIONS WHERE RIGID CONDUIT IN NOT PRACTICAL. FINAL CONNECTIONS TO VIBRATING EQUIPMENT. FINAL CONNECTIONS TO MOTORS. IN WALLS (FOR LIGHT SWITCHES AND 120 VOLT POWER RECEPTACLES AND HVAC CONTROL EQUIPMENT). INTER-CONNECTIONS BETWEEN ALL LIGHT FIXTURES AND HOMERUNS TO PANELS WHERE CODE ALLOWS. THE USE OF ROMEX, BX, ETC. IS PERMITTED ONLY IN RESIDENTIAL CONSTRUCTION NOT HIGHER THAN THREE STORIES. ALL WIRING TO BE COLOR-CODED AS FOLLOWS: ON ALL 20 AMP BRANCH CIRCUITS, CONDUCTORS LARGER THAN #10 AWG SHALL BE REDUCED TO #10 AWG WITHIN 10 FEET OF PANEL BOARD AND DEVICE IN JUNCTION BOXES ON RATED TERMINAL STRIPS. CONDUCTORS MAY BE STRANDED FOR SIZES #10 AWG AND LARGER. CONDUCTORS SIZE #12 SHALL BE SOLID (NOT STRANDED). ALUMINUM CONDUCTORS ARE NOT PERMITTED, EXCEPT AT SERVICE ENTRANCE, WHERE REQUIRED BY LANDLORD. CONDUCTOR CONNECTION MUST BE PER MANUFACTURER'S REQUIREMENTS. CONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM GENERAL CONTRACTOR AND PROJECT MANAGER WHEN USED. ALL WIRING (120V AND ABOVE) SHALL BE IN CONDUIT, UNLESS SPECIFICALLY NOTED OTHERWISE. ALL LOW VOLTAGE WIRING CONDUIT REQUIREMENTS TO BE COORDINATED WITH OWNER. THE USE OF SHARED NEUTRALS IS REQUIRED FOR LIGHTING CIRCUITS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL CODES. ALL OTHER EQUIPMENT REQUIRING A NEUTRAL CONDUCTOR SHALL HAVE A DEDICATED FULL SIZE NEUTRAL. WIRE CONNECTORS SHALL BE EQUAL TO "SCOTCH LOCK" FOR #8 AWG WIRE AND SMALLER AND EQUAL TO T & B "LOCKTIGHT" FOR #6 AWG AND LARGER. 277/480 VOLT SYSTEM NEUTRAL - GRAY PHASE A OR L1 - BROWN PHASE B OR L2 - ORANGE PHASE C OR L3 - YELLOW GROUND - GREEN WITH YELLOW TRACER A. 2. a. b. c. d. PHASING REQUIREMENTSJ. 1. 1. DEMOLITION 2. K. THIS CONTRACTOR IS TO INCLUDE IN HIS BID ALL NECESSARY SERVICE REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE'S ELECTRICAL SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE IN WRITING WITH TENANT/ARCHITECTS AND THE LANDLORD ONE WEEK PRIOR TO ANY SHUT DOWN OF THE ELECTRICAL SYSTEM. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. SECTION 16000 DIVISION 16 - ELECTRICAL 1. 2. NOTEA. BASIC ELECTRICAL REQUIREMENTS 4. 3. 5. 1. B.GENERAL REQUIREMENTS 2. 3. 5. 4.ALL WORK IN THIS SECTION SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF THE CONTRACT. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE ELECTRICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR ARCHITECTS SHALL BE PROVIDED BY THIS CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND ARCHITECTS, AS REQUIRED. REFER TO RESPONSIBILITY SCHEDULE FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT THE BID. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY DISCREPANCIES OR ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF HIS WORK. THIS ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK TO COMPLY WITH TENANT/ARCHITECT'S SCHEDULE AND THE PROJECT COMPLETION DATE. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF HIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 16. 2. d. c. 4. 5. SLEEVES 1. 2. HANGERS 3. M. L. 1. 2. 1. 3. FINAL ELECTRICAL INSPECTIONSN. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, TENANT/ARCHITECTS MAY HAVE AN INDEPENDENT ELECTRICAL CONTRACTOR INSPECT THE FINISHED ELECTRICAL INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT ELECTRICAL CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DIELECTRICALLY SEPARATED. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C-CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. a. 6. END OF SECTION 16000 6. 7. 1. 8. C. 2. TEMPORARY LIGHT AND POWER 1. CODESD. 1. E. 2. F.TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS LICENSES, PERMITS, INSPECTIONS & FEES 1. 2. ALL WORK SHALL CONFORM TO THE LANDLORD'S CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS AWARDED, CHANGE ORDERS FOR INCREASED COSTS DUE TO CODE ISSUES WILL NOT BE ACCEPTED BY OWNER, UNLESS ALLOWANCES HAVE PREVIOUSLY BEEN AGREED UPON. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO ARCHITECTS/ENGINEERS FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR ARCHITECTS/ENGINEERS REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP AND/OR THE SIGNATURE OF THE GENERAL CONTRACTOR AND THE SUB-CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY ARCHITECTS/ENGINEERS THROUGH SHOP DRAWING SUBMITTAL PROCESS FOR ACCEPTANCE PRIOR TO INSTALLATION. THE USE OF ANY UNATHORIZED EQUIPMENT SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. FURNISH TO ARCHITECTS ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. THE ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING AND CHANNELING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY THE ARCHITECTS AND THE LANDLORD. ALL PATCHING SHALL BE BY G.C. AND SHALL MATCH THE SURROUNDING SURFACES. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL TEMPORARY WIRING AND RELATED GROUND FAULT INTERRUPTION PROTECTION FOR LIGHT AND POWER FOR ALL CONTRACTORS AND SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL TEMPORARY WIRING. THE GENERAL CONTRACTOR SETS UP ALL ELECTRICAL UTILITIES IN THE NAME OF THE TENANT. TENANT PAYS FOR ALL UTILITIES THROUGHOUT CONSTRUCTION. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD CONSTRUCTION PRACTICES. THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING ELECTRICAL EQUIPMENT, CONDUITS, ETC. NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT PRIOR TO REMOVAL. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED CONDUIT OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED CONDUIT MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE: GENERALLY, ALL CONDUIT SHALL BE CONCEALED EXCEPT FOR UNFINISHED AREAS, SUCH AS EQUIPMENT ROOMS. EXPOSED CONDUIT SHALL BE ALLOWED ONLY AS NOTED ON PLAN AND AS APPROVED BY PROJECT MANAGER. PAINTING OF CONDUITS, NOTED ON DRAWINGS OR SPECIFICATIONS WILL BE BY GENERAL CONTRACTOR. A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM INCLUDING THE INSTALLATION OF SAFETY AND DISCONNECT SWITCHES, MOTOR STARTERS AND LIGHTING. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO INCLUDE IN HIS BID FOR PROVIDING SERVICE EQUIPMENT NECESSARY FOR TIE-IN TO LANDLORD'S DISTRIBUTION EQUIPMENT OR TO OBTAIN SERVICE FROM LOCAL UTILITY COMPANY. REFER TO ELECTRICAL RESPONSIBILITY SCHEDULE AND ELECTRICAL POWER RISER DIAGRAM FOR ADDITIONAL INFORMATION. ALL CONDUITS SHALL BE GALVANIZED IMC OR EMT UNLESS OTHERWISE SPECIFIED IN SPECIFICATIONS OR ON DRAWINGS. ALL CONDUIT IS TO BE UL LABELED. EMT CONNECTORS SHALL BE STEEL COMPRESSION OR SET SCREW TYPE. CONDUIT UNDER SLAB ON GRADE SHALL BE RIGID STEEL, OR SCHEDULE 40 PVC WITH RIGID STEEL ELLS WHERE PERMITTED BY LANDLORD OR CODE. EMT FOR WET LOCATIONS TO BE PERMITTED ONLY WHEN ALL SUPPORTS, BOLTS, STRAPS, SCREWS AND SO FORTH ARE CORRISION-RESISTANT MATERAILS PER 358.10. ALL IN/UNDER FLOOR CONDUIT SHALL BE OF MINIMUM 3/4" SIZE. IF HVAC CONTROL WIRING IS REQUIRED TO BE RUN IN CONDUIT, IT SHALL BE A MINIMUM OF 3/4", UNLESS NOTED OTHERWISE ON DRAWINGS. SUPPORT ALL CONDUIT, INCLUDING SEISMIC AND SWAY BRACING, IN ACCORDANCE WITH THE NEC AND LOCAL CODES. THE WIRING OF MECHANICAL EQUIPMENT AS OUTLINED ON THE BID SET DRAWINGS AND IN THE SPECIFICATIONS. WORK SHALL INCLUDE WIRING OF ALL STARTERS, DISCONNECTS, AND POWER WIRING OF MECHANICAL EQUIPMENT EXCEPT AS SPECIFICALLY NOTED OTHERWISE. ALL LOW VOLTAGE (24 VOLT) EMS TEMPERATURE CONTROL WIRING SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR UNLESS NOTED SPECIFICALLY ON DRAWING. METERING AND CURRENT TRANSFORMERS AS REQUIRED BY DRAWINGS, UTILITY COMPANY, AND/OR LANDLORD. CONTRACTOR MUST ALSO INCLUDE IN BID ALL NECESSARY MATERIALS REQUIRED TO COMPLETE THE SYSTEM INCLUDING, BUT NOT LIMITED TO, FEEDERS, BRANCH CIRCUITS, JUNCTION BOXES, OUTLET BOXES, WIRING DEVICES, COVER PLATES, CONDUITS, ETC. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: CONTRACTOR NOTES 2. 6. 5. 4. 3. FLEXIBLE CONDUIT OR MC TYPE CABLE SHALL BE USED FOR THE FOLLOWING APPLICATIONS ONLY: 1. 1. GUARANTEEG. THE EQUIPMENT MANUFACTURER SHALL PROVIDE A 12 MONTH GUARANTEE TO TENANT FROM THE DATE OF ACCEPTANCE. THIS CONTRACTOR SHALL WARRANTY THE INSTALLATION OF THIS EQUIPMENT AND WILL BE RESPONSIBLE FOR ANY DAMAGE AND/OR MALFUNCTION CAUSED BY THE INSTALLATION. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM. b. c. d. 7. 8. 9. 10. 1. OUTLET BOXESC. 2. 4. 3. ALL CONDUITS MUST BE SIZED PER NEC AND LOCAL CODES. ALL SENSORMATIC WIRING MUST BE PLACED IN CONDUIT (PVC PIPE NOT PERMITTED). EXTERIOR BOXES SHALL BE CAST RUST-RESISTING METAL WITH GASKETED COVERS. PROVIDE PULL-WIRE IN ALL EMPTY CONDUITS EXCEPT AS NOTED OTHERWISE ON DRAWINGS. HOME RUNS AND MAIN CONDUIT RUNS ARE TO BE HELD TIGHT TO STRUCTURE ABOVE OR AS REQUIRED TO ALLOW PROPER SERVICE ACCESS AND OTHER TRADES WORK. CONDUIT MUST BE TRAPEZED TO ALLOW 3 FEET MINIMUM CLEARANCE ABOVE CEILING. ALL OUTLET BOXES SHALL BE GALVANIZED PRESSED STEEL OF THE STANDARD KNOCKOUT TYPE. NO ROUND OUTLET BOXES SHALL BE PERMITTED UNLESS INDICATED AND FOR LIGHTING THAT REQUIRE SUCH CONFIGURATION. CONCEALED BOXES SHALL NOT BE LESS THAN 4" SQUARE AND 1 1/2" DEEP, WITH PLASTER RINGS. ALL KNOCKOUT BOXES, UPON WHICH LIGHTING FIXTURES ARE TO BE INSTALLED, SHALL BE EQUIPPED WITH 3/8" FIXTURE STUDS. INSTALL BOXES RIGIDLY FROM BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF FLOORS, CEILINGS, WALLS ETC. ALL OUTLET BOXES TO BE PROVIDED WITH CADDY "QUICK-MOUNT BOX SUPPORT" TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING/UNPLUGGING INTO THESE DEVICES. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE MUST BE THE SAME SIZE AS THE IMC OR EMT CONDUIT TO WHICH IT IS CONNECTED. BOTH THE FLEXIBLE METAL CONDUIT AND IT'S FITTINGS ARE TO BE LISTED FOR GROUNDING. A GREEN GROUNDING CONDUCTOR SHALL BE INSTALLED. ALL CONNECTORS ARE TO BE OF A NEMA APPROVED TYPE. THE USE OF ROMEX, BX, ETC. IS PERMITTED ONLY IN RESIDENTIAL CONSTRUCTION NOT HIGHER THAN THREE STORIES. CONNECTION TO ANY OUTDOOR EQUIPMENT MUST BE WEATHERPROOF. 1. c. b. a. RECORD DRAWINGSH. THIS CONTRACTOR SHALL MAINTAIN ONE SET OF DRAWINGS ON THE JOB SITE UPDATED WEEKLY TO RECORD ALL DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: REVISIONS, ADDENDUMS, AND CHANGE ORDERS. LOCATION OF CONCEALED CONDUIT AND EQUIPMENT. 2. 1. DISCREPANCIES IN DOCUMENTSI. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THIS CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. FAILURE TO KEEP THESE RECORDS WILL ALLOW TENANT/ARCHITECTS TO DIRECT THE GENERAL CONTRACTOR TO PROVIDE THESE RECORDS AT HIS EXPENSE PRIOR TO FINAL PAYMENT. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE ELECTRICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, TENANT/ARCHITECT'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. e. g. f. h. i. k. j. l. n. 3. a. b. 4. m. TELEPHONE INSTRUMENTS AND WIRING UNLESS NOTED OTHERWISE. AS-BUILTS, PANEL DESCRIPTION AND CIRCUIT BREAKER SPECIFIC LABELING. THE FOLLOWING ITEMS OF ELECTRICAL CONSTRUCTION ARE NOT INCLUDED IN THIS CONTRACT: BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, FIRE PROTECTION, MECHANICAL AND PLUMBING PLANS, SHOP DRAWINGS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE ELECTRICAL SYSTEM, MATERIALS AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. DATA CABLE WIRING UNLESS NOTED OTHERWISE. INSTALLATION OF CONDUITS STUBBED TO ABOVE CEILING FOR HVAC. ALSO, ANY ADDITIONAL CONDUIT FOR HVAC CONTROL EQUIPMENT WHERE PLENUM RATED CABLES ARE NOT PERMITTED. SMOKE/FIRE ALARM WIRING, DEVICES AND CONDUIT, AS SHOWN OR DESCRIBED ON DRAWINGS OR AS NECESSARY TO MEET LANDLORD, STATE, LOCAL, INSURANCE AND FIRE DEPARTMENT REQUIREMENTS. IF INDICATED ON DRAWINGS, INSTALLATION AND WIRING OF SPEAKERS, AMPLIFIERS, CONDUIT AND FINAL CONNECTIONS FOR SOUND SYSTEM AS SHOWN. FINAL CONNECTIONS TO ALL SIGNS, CORNICE LIGHTING, CASE LIGHTING, ETC. AS SHOWN ON DRAWINGS. TEMPORARY SERVICE AS INDICATED IN THE SPECIFICATIONS, INCLUDING ITS REMOVAL. A COMPLETE EMERGENCY AND EXIT LIGHTING SYSTEM AS SHOWN ON THE DRAWINGS. A COMPLETE CONDUIT SYSTEM FOR TELEPHONE/DATA INCLUDING BRANCH CONDUITS, OUTLET BOXES, PULL WIRES, GROUND CONDUCTORS, COVER PLATES, ETC. OR AS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. INSTALLATION OF LIGHT FIXTURES AND LAMPS AS SHOWN ON THE DRAWINGS INCLUDING ALL DEVICES, EQUIPMENT, ETC. REQUIRED FOR MOUNTING. BALANCING LOADS. 1. B. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS SERVING ALL EQUIPMENT, INCLUDING BUT NOT LIMITED TO, LIGHTING, RECEPTACLES, HEATING, AIR CONDITIONING, PLUMBING EQUIPMENT, TELEPHONE, DATA, SPEAKERS, SECURITY, PAGER, TRAFFIC COUNTING SYSTEM AND ELECTRICAL EQUIPMENT. CONDUIT b. a. c. 1. 2. D.JUNCTION AND PULL BOXES CONVENIENCE OUTLETS: BOXES AND COVERS SHALL BE GALVANIZED STEEL OF CODE GAUGE SIZE. THE PLANS INDICATE ONLY SCHEMATIC ROUTINGS FOR CONDUIT RUNS. THIS CONTRACTOR SHALL FURNISH AND INSTALL ADDITIONAL BOXES WHERE REQUIRED BY FIELD CONDITIONS OR BY CODE. MOUNTED ON WALL NO MORE THAN 48-INCHES, MEASURED FROM TO TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING AND; NO LESS THAN 15-INCHES, MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, TO THE LEVEL OF THE FINISHED FLOOR OR WORKING PLATFORM UNLESS OTHERWISE INDICATED OR HORIZONTALLY MOUNTED IN BASEBOARD BENEATH CABINETS, AS SHOWN ON DRAWINGS, OR AS REQUIRED BY LOCAL CODES, SEE DRAWINGS. SWITCH HEIGHT 48" FROM FINISHED FLOOR TO TOP OF OUTLET. TELEPHONE OUTLETS SHALL BE LOCATED AS NOTED ON DRAWINGS. 4. 3. WIRING 5. E. 1. 2. b. a. #10 BETWEEN 100-150 FEET #12 LESS THAN 100 FEET d. c. #6 OVER 250 FEET #8 BETWEEN 150 - 250 FEET INSTALL BOXES RIGIDLY SUPPORTED FROM THE BUILDING STRUCTURE AND SUPPORTED INDEPENDENT OF THE CONDUIT SYSTEM. ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHOULD BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. JUNCTION AND PULL BOXES MUST BE LABELED WITH CIRCUIT NUMBER IDENTIFICATION AND SYSTEM TYPE ON COVER. CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS SHALL BE COPPER AND THE AWG SIZE AND TYPE AS SHOWN ON DRAWINGS. MINIMUM WIRE SIZE #12. THE CONDUCTORS SHALL BE 600 VOLT INSULATION, TYPE THW, THWN OR THHN. MINIMUM WIRE SIZE - 20 AMP BRANCH CIRCUIT SHALL BE AWG LISTED SIZE PER DISTANCE SHOWN BELOW. DISTANCE SHALL BE MEASURED FROM THE PANELBOARD CIRCUIT BREAKER TO THE FURTHEST OUTLET. 3. b. a. 1/2" FOR INDIVIDUAL LIGHTING FIXTURE CONNECTIONS OR TO INDIVIDUAL LIGHT SWITCHES (IF ACCEPTABLE BY THE LANDLORD AND LOCAL CODE OFFICIALS) AND 3/4" FOR ALL OTHER LOCATIONS. MAIN FEEDER CONDUIT 2" OR LARGER FOR ALL APPLICATIONS. MINIMUM SIZE OF CONDUIT SHALL BE: 1.IT IS CONTRACTOR/ELECTRICIANS' RESPONSIBILITY TO FIELD VERIFY ACTUAL SITE CONDITION AND SHALL NOTIFY EOR(S) ANY DISCREPANCIES WITH THE PLAN THAT IMPACTS ON THE BID PRIOR TO BIDDING. SCOPE OF WORK ELECTRICAL SYMBOLS LIST WALLCLG.DESCRIPTIONFLR. DUPLEX RECEPTACLE AT +18" FOR WALL MOUNTED U.O.N. DOUBLE DUPLEX RECEPTACLE AT + 18" FOR WALL MOUNTED U.O.N. DUPLEX RECEPTACLE WITH USB 2.0 PORT GROUND CONNECTOR MAIN SWITCHBOARD OR POWER DISTRIBUTION BOARD. VERIFY DIMENSION WITH VENDER/MANUFACTURER. ELECTRICAL PANEL. REFER TO PANEL SCHEDULE FOR DETAILS. INDICATES PLAN NOTE NUMBER "1", SEE PLAN JUNCTION BOX CONDUIT STUB OUT, 3/4" MINIMUM - SEE PLANS FOR NOTES CONDUIT CONCEALED ABOVE CEILING OR IN WALLS HOMERUN TO PANEL "A", CIRCUITS #1A-1 USB SPECIAL NEMA RECEPTACLE. SEE EQUIPMENT PLAN/INSTALLATION MANUAL FOR SPECS AND DETAILS. COMBINATION TELEPHONE, DATA AND CABLE OUTLET AT +18" U.O.N. PROVIDE 1/2"C.O. STUBBED TO ACCESSIBLE CEILING SPACE TELEPHONE OUTLET; CAT5E CABLE. RJ11 TERMINATION MOUNTED AT +18" PROVIDE 1/2"C.O. STUBBED TO ACCESSIBLE CEILING SPACE DATA OUTLET; CAT5E CABLE, RJ45 TERMINATION MOUNTED AT +18" U.O.N. PROVIDE 1/2"C.O. STUBBED TO ACCESSIBLE CEILING SPACE CABLE OUTLET; RG-6 COAXIAL CABLE. MOUNTED AT +18" U.O.N. PROVIDE 1/2"C.O. STUBBED TO ACCESSIBLE CEILING SPACE LIGHTING FIXTURE WITH 90 MIN. EMER. BATTERY PACK OR ON INVERTER SEE LIGHT FIXTURE SCHEDULE FOR DETAILS AND SPECS DENOTES EQUIPMENT #1, SEE EQUIPMENT SCHEDULE FOR THE DETAILS AND EXACT SPECIFICATIONS. DENOTES MECHANICAL EQUIPMENT #1 SEE MECHANICAL DRAWINGS FOR THE DETAILS AND SPECIFICATIONS. SINGLE POLE SWITCH AT 48" U.O.N. DIMMER SWITCH/DIMMING WALL CONTROL STATION AT +48" U.O.N. THREE-WAY SWITCH AT +48" U.O.N. THREE-WAY DIMMER SWITCH AT +48" U.O.N. MANUAL MOTOR STARTER VS DL S/C MOTOR OUTLET - IDENTIFICATION ABBREVIATION FOR NEW / EXISTING / REPLACED /RELOCATED SYMBOL NOTES: NON-FUSED/FUSED SWITCH, SIZE AS SHOWN IN THE PLAN OS (N) / (E) / (RP) / (RL) OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL SWITCHING AT +48" U.O.N./MANUFACTURER TO BE DETERMINED VACANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL SWITCHING AT +48" U.O.N./MANUFACTURER TO BE DETERMINED OCCUPANCY SENSOR SINGLE POLE SWITCH WITH DIMMER CONTROL FEATURE AT +48" U.O.N./MANUFACTURER TO BE DETERMINED CEILING MOUNTED OCCUPANCY SENSOR MANUFACTURER TO BE DETERMINED CEILING MOUNTED VACANCY SENSOR MANUFACTURER TO BE DETERMINED CEILING MOUNTED DAYLIGHT SENSOR MANUFACTURER TO BE DETERMINED TIME CLOCK WITH MANUAL BY-PASS SWITCH SEE LIGHTING CONTROL DIAGRAM FOR DETAILS SYMBOL LIST SHOW IN FOR GENERAL REFERENCE ONLY. A PRESENCE OF A SYMBOL DOES NOT IMPLY ITS USE ON THIS PROJECT. REFER TO DRAWING FOR SPECIFIC SYMBOLS USED. S C HARD WIRED, WITH BATTERY BACKUP, SMOKE DETECTOR/CARBON MONOXIDE DETECTOR/MULTI-PURPOSE CARBON MONIXIDE & SMOKE DETECTOR. T C F M D D OS VS OS/D J J J S S S 3 3 EXHAUST AIR GRILLE - REFER TO MECHANICAL PLAN --- 1 1 GROUND FAULT INTERRUPTING PROTECTED CIRCUIT DUPLEX RECEPTACLE PROVIDE GFCI BREAKER INSTEAD OF GFCI OUTLET AS NECESSARY CEILING POWER DROP. DROP HEIGHT TO BE VERIFIED WITH OWNER/ARCHITECT. 1 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 2:42:47 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 N.T.S. E000 ELECTRICAL SPECIFICATION J.L.K.P. C TS OVERRIDE SWITCH TO LIGHTSA-1 A-3 TIME CLOCK 120V AC 2-HOUR TIMER SWITCH LIGHTING CONTROL DIAGRAM TO SIGNAGE LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION LAMP VOLT WATT L1 2X4 RECESSED LED TROFFER LIGHT, DIMMABLE LITHONIA 2GTL4 SERIES OR APPROVED EQUAL LED 120 43 L2 6" LED RECESSED DOWNLIGHT, DIMMABLE LITHONIA LDN6 SERIES OR APPROVED EQUAL LED 120 18 L3 LED PENDANT FIXTURE, DIMMABLE WAC LIGHTING DWELED TIC TOC SERIES OR APPROVED EQUAL LED 120 15 EE LIGHT FIXTURE WITH 90 MINUTES EMERGENCY BATTERY PACK VERIFY WITH MANUFACTURER FOR OPTION/INVERTER IF NOT AVAILABLE ---120 --- EM EMERGENCY LED LIGHT WITH 90 MINUTES BATTERY PACK LITHONIA EU2L (WALL), ELR2 (CEILING), ELAQWP (OUTDOOR) SERIES OR EQUIVALENT ---120 --- X LED EXIT SIGN WITH 90 MINUTES BATTERY PACK LITHONIA EXR LED M6 OR EQUIVALENT ---120 --- 120V, SINGLE POLE, MAX 3% VOLTAGE DROP LENGTH OF RUN COPPER COPPER COPPER COPPER COPPER ALUMINUM ALUMINUM AMP LOAD200'150'100'50'25' 14 12 10 1 1/0 3/0 250 12 12 10 1 1/0 3/0 250 10 8 6 1 2/0 3/0 300 8 6 4 2/0 4/0 300 600 6 4 4 4/0 300 500 900 15 AMP 20AMP 30 AMP 100 AMP 100 AMP 200 AMP 200 AMP NOTE: THE MAXIMUM COMBINED VOLTAGE DROP ON BOTH INSTALLED FEEDER CONDUCTORS AND BRANCH CIRCUIT CONDUCTORS TO THE FARTHEST CONNECTED LOAD OR OUTLET SHALL NOT EXCEED 5 PERCENT. EMERGENCY EXIT ILLUMINATION NOTES 1.FIXTURES WITH 90 MIN. EMERGENCY BATTERY BACKUP SHALL BE WIRED AHEAD OF ANY CONTROL IN COMPLIANCE WITH [2022 CEC 700.12(I)(2)(3)(A)]. 2.THE MEANS OF EGRESS SERVING A ROOM OR SPACE SHALL BE ILLUMINATED AT ALL TIMES THAT THE ROOM OR SPACE IS OCCUPIED. [2022 CBC 1008.2] 3.THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ONSITE GENERATOR. [2022 CBC 1008.3.4] 4.EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT LESS THAN AN AVERAGE OF 1 FC, AND A MIN AT ANY POINT OF 0.1 FC MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FC AVERAGE AND A MIN AT ANY POINT OF 0.06 FC AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAX-TO-MIN ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. [2022 CBC 1008.3.5] 5.EXITS AND EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXIT SIGN READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. EXIT SIGN PLACEMENT SHALL BE SUCH THAT ANY POINT IN AN EXIT ACCESS CORRIDOR OR EXIT PASSAGEWAY IS WITHIN 100 FT OR THE LISTED VIEWING DISTANCE OF THE SIGN, WHICHEVER IS LESS, FROM THE NEAREST VISIBLE EXIT SIGN. [2022 CBC 1013.1] 6.TACTILE EXIT SIGNS SHALL BE PROVIDED WITH APPROPRIATE WORDS AT EXIT DOORS LEADING TO ENCLOSED EXIT STAIRWAYS AND EXIT DOORS LEADING TO OUTSIDE. [2022 CBC 1013.4] 7.EMERGENCY LIGHTING UNITS SHALL BE EQUIPPED WITH FACTORY INSTALLED INTEGRAL TEST SWITCHES. NOTES: 1.FIXTURE SHALL HAVE MIN. OF 10 YEARS MANUFACTURER WARRANTY ON ALL COMPONENTS. 2.FIXTURES SHALL HAVE APPROPRIATE U.L. LABEL (i.c., DAMP OR WET) AS REQUIRED BY CODES AND ORDINANCES. 3.FIXTURES SHALL INCLUDE ALL ACCESSORIES FOR INSTALLATION ACCORDING TO MANUFACTURER'S SHOP DRAWINGS AND AS REQUIRED BY CODES AND LOCAL ORDINANCES. 4.PRIOR TO ORDERING ANY LIGHTING EQUIPMENT, THE CONTRACT OR SHALL COORDINATE ALL FIXTURE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND CEILING CAVITY DEPTHS. 5.ALL LAMPS SHALL BE PROVIDED AND INSTALLED ACCORDING TO THE ATTACHED FIXTURE SCHEDULE AND SPECIFICATIONS. ENSURE COMPATIBILITY BETWEEN FIXTURE, LAMP(S) AND BALLAST(S). 6.CONTRACTOR SHALL VERIFY FIXTURE VOLTAGES AND CEILING TRIM COMPATIBILITY PRIOR TO ORDERING FIXTURE. 7.PROVIDE APPROVED FIRE-RATED ENCLOSURES FOR ALL LIGHTING FIXTURES LOCATED IN FIRE-RATED CEILINGS. 8.LIGHTING FIXTURE CATALOG NUMBERS ARE SERIES TYPE ONLY. PROVIDE ALL NECESSARY HARDWARE AS REQUIRED BY THE SPECIFICATIONS, DRAWINGS, AND PROJECT CONDITIONS FOR A COMPLETE INSTALLATION. 9.ALL FIXTURES SHALL BE ORDERED WITH APPROPRIATE BALLAST(S) THAT HAVE U.L. AND CBM LABELS. PROVIDE MULTIPLE BALLASTS FOR DUAL-LEVEL SWITCHING AND WIRING AS INDICATED ON THE PLANS. 10.ENSURE COMPATIBILITY OF ALL LIGHTING SYSTEM COMPONENTS, ESPECIALLY DIMMED SYSTEMS. FIXTURES, LAMPS, BALLAST(S), AND DIMMING SYSTEMS/INDIVIDUAL CONTROLS MUST BE FACTORY CERTIFIED COMPATIBLE FOR FULL RANGE OF DIMMING COMPATIBILITY. 11.LIGHTING FIXTURE MANUFACTURER & MODEL IS FOR REFERENCE ONLY. FIXTURE SHALL BE SELECTED BY ARCHITECT. POWER AND QUALITY SHALL BE SPECIFICATION GRADE. SINGLE LINE DIAGRAM NOTES 1.CONTRACTOR/ELECTRICIAN TO FIELD VERIFY ACTUAL SITE CONDITION /EXACT SERVICE ENTRANCE AND SHALL NOTIFY EOR(S) ANY DISCREPANCY WITH THE PLAN PRIOR TO BIDDING. 2.CONTRACTOR TO VERIFY ALL EQUIPMENT DIMENSIONS AND CLEARANCES WITH FIELD CONDITION PRIOR TO ORDERING EQUIPMENT. 3.ALL EQUIPMENT TO BE LISTED BY A RECOGNIZED TESTING AGENCY. TERMINALS TO BE RATED FOR ALUMINUM AND COPPER WIRE. 4.CONTRACTOR TO OBTAIN A FAULT CURRENT LETTER FROM UTILITY COMPANY PRIOR TO PURCHASE OF ANY EQUIPMENT (IF ANY) FOR AIC VERIFICATION. EQUIPMENT CUTSHEETS AND FAULT CURRENT LETTER TO BE PROVIDED UPON INSPECTION. 5.IF APPLICABLE, ALL NEW CIRCUIT BREAKERS INSTALLED ON EXISTING PANEL/SWITCHBOARD SHALL MATCH THE HIGHEST EXISTING AIC RATED BREAKER WITHIN THAT PANEL/BOARD. INSPECTOR TO VERIFY HIGHEST AIC RATING AT THE SITE. 6.MAIN SERVICE DISCONNECT AMPERAGE MUST BE PERMANENTLY MARKED 7.ALL SYSTEM TO BE FULLY RATED SYSTEM. IF SYSTEM IS SERIES RATED, ALL COMPONENTS MUST BE FROM THE SAME MANUFACTURER. LISTED BREAKER COMBINATIONS SHALL BE AVAILABLE TO THE AUTHORITY HAVING JURISDICTION UPON REQUEST. 8.IF APPLICABLE, ALL EQUIPMENT LABELED/IDENTIFIED AS EXISTING, ARE SUBJECT TO FIELD VERIFICATION. 9.ARC-FLASH HAZARD WARNING FIELD MARKING TO BE PROVIDED ON ELECTRICAL EQUIPMENT, SUCH AS SWITCHBOARDS, PANEL BOARDS, METER SOCKET ENCLOSURES AND MCC THAT ARE IN OTHER THAN DWELLING UNITS. [2022 CEC 110.16, 110.21(B)] 10.SERVICE EQUIPMENT SHALL BE FIELD MARKED WITH THE MAXIMUM AVAILABLE FAULT CURRENT. [2022 CEC 110.24] SINGLE LINE DIAGRAM FEEDER CHART (E)/(N)FEEDER SIZE S1.2K (E)(4) 4#600, #350GND- 4"C 200 (N)4#350, #4GND- 3"C NOTE: (E) FEEDERS TO BE FIELD VERIFIED AND REMAIN AS-IS U.O.N. # S(Override) = LIGHTING OVERRIDE SWITCH, AT FRONT DOOR. TC = LIGHTS TIME CLOCK WITH OVERRIDE ON/OFF CONTROL SPECIFIC NOTES: DESIGNATED NON EMERGENCY LIGHTING CIRCUITS SHALL BE CONTROLLED BY 24 HR TIME CLOCK THROUGH MULTI-POLE CONTACTOR. TIME CLOCK SHALL INCORPORATE AN AUTOMATIC HOLIDAY "SHUT-OFF" FEATURE. INTERMATIC ET2800 SERIES (INDOOR)/ET8000 SERIES (OUTDOOR) OR EQUIV. (E) FROM MAIN SWITCHBOARD "MSA2" (ELECTRICAL ROOM) (E) 200A 3P (E) MAIN SWITCHBOARD "MSA3" 1200A, 120/208V, 3Ø, 4W 65K AIC RATING, NEMA 1 ENCLOSURE (E) 1200A 3P M (N) PANEL "A" 200 SELF TAPPING SCREWS STANDARD COLORS: 1. NORMAL POWER - BLACK BACKGROUND, WHITE LETTERS 2. EMERGENCY POWER - RED BACKGROUND, WHITE LETTERING NAMEPLATES ARE REQUIRED ON ALL PANELBOARDS, STARTERS AND DISCONNECT SWITCHES. PANELBOARD PANEL "X" PANELBOARD DESIGNATION ALL PANELS SHALL BE LABELED ON INSIDE OF DOOR WITH LIST OF CIRCUITS AND THEIR APPROPRIATE NAMES. 3" 1" EACH PANEL SCHEDULE TO INDICATE THE SOURCE OF POWER TO THE PANEL. THE LABEL SHALL BE PERMANENTLY AFFIXED. NAMEPLATE (TYPICAL) ENGRAVED LAMACOID, 5/32 INCH LETTERS PANEL BOARD NAMEPLATE DETAIL SCALE NTS 1 OCCUPANCY SENSOR CONTROL DETAIL SCALE NTS 3120V GFCI BREAKER WIRING DIAGRAM SCALE NTS 2 S1.2K D=180' %VD=1.70 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 2:42:50 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 N.T.S. E001 SINGLE LINE DIAGRAM/ SCHEDULES J.L.K.P. UP DNUP 95.5000 131.0000 126.0000 109.7500 82.0000 58.0000 189.0003 77.0000 83.0000 457.0000 180.0000 5.9373FIRE AREA 1 - W2 30.1873FIRE AREA 4 - W2 11.1632 DAYLIGHT CONTROL EXCEPTION NOTES: DAYLIGHT CONTROL: COMBINED TOTAL GENERAL LIGHTING POWER IN PRIMARY/SECONDARY SIDELIT DAYLIT ZONE IS LESS THAN 120 WATTS. NO DAYLIGHT CONTROL REQUIRED. [2022 CENC130.1(D)EXCEPTION(3)] LIGHTING PLAN 1.EMERGENCY/NL AND EXIT FIXTURES TO BE CONNECTED TO NEARBY ROOM LIGHTING CIRCUIT AHEAD OF LOCAL SWITCH. [2022 CEC 700.12(I)(2)(3)(A)]. 2.CONTRACTOR TO VERIFY FINAL LOCATION OF SWITCH/DIMMER/CONTROL PACK WITH THE ARCHITECT/OWNER PRIOR TO ROUGH-IN. 3.INTERLOCK RESTROOM LIGHT WITH EXHAUST FAN AND PROVIDE MANUAL MOTOR SWITCH IF NOT PLUG/BUILT-IN. 4.WIRE THRU CONTACTOR & TIME CLOCK FOR SIGNAGE LIGHTING CONTROL. #KEYED PLAN NOTES: GENERAL NOTES: 1.ELECTRICAL EQUIPMENT SHALL BE LISTED BY U.L. OR CITY RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE CITY DEPARTMENT. 2.ALL ELECTRICAL WORK SHALL COMPLY WITH THE [2022 CEC]. 3.WIRE SIZE SHALL NOT BE LESS THAN CORRESPONDING CIRCUIT BREAKER RATING AS REQUIRED. [2022 CEC TABLE 310.16] 4.CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE [2022 CEC ANNEX C]. 5.CONTRACTOR/ELECTRICIAN TO FIELD VERIFY ACTUAL SITE CONDITION /EXACT SERVICE ENTRANCE AND SHALL NOTIFY EOR(S) ANY DISCREPANCY WITH THE PLAN PRIOR TO BIDDING. 6.ALL ITEMS LABELED/IDENTIFIED AS EXISTING (IF ANY) ARE SUBJECT TO FIELD VERIFICATION. VERIFY EXISTING CONDITION AND RE-USE. IF NOT EXISTING, PROVIDE PER PLAN. 7.OBTAIN APPROVAL ON LOCATION OF SWITCH/DIMMER/SENSOR WITH ARCHITECT/OWNER AT SITE PRIOR TO ROUGH-IN. 8.SIGNAGE WILL REQUIRE SEPARATE PERMIT AND SUBMITTAL. 9.REFER TO EMERGENCY EXIT ILLUMINATION NOTES FOR EMERGENCY LIGHTING REQUIREMENTS. 10.IN OFFICES 250 SQUARE FEET OR SMALLER, MULTIPURPOSE ROOMS OF LESS THAN 1,000 SQUARE FEET, CLASSROOMS OF ANY SIZE, CONFERENCE ROOMS OF ANY SIZE, AND RESTROOMS OF ANY SIZE, LIGHTING SHALL BE CONTROLLED WITH OCCUPANT SENSING CONTROLS TO AUTOMATICALLY SHUT OFF ALL OF THE LIGHTING IN 20 MINUTES OR LESS AFTER THE CONTROL ZONE IS UNOCCUPIED. [2022 CENC 130.1(C)(5)] A.IN AREAS W/ MULTI-LEVEL LIGHTING CONTROLS, THE OCCUPANT SENSING CONTROLS SHALL FUNCTION AS A PARTIAL-ON OCCUPANT SENSING CONTROLS CAPABLE OF AUTOMATICALLY ACTIVATING BETWEEN 50 AND 70 PERCENT OF CONTROLLED LIGHTING POWER B.IN AREAS W/O MULTILEVEL LIGHTING CONTROLS, THE OCCUPANT SENSING CONTROLS SHALL FUNCTION AS A VACANCY SENSING CONTROLS, WHERE ALL LIGHTING RESPONDS TO A MANUAL ON INPUT ONLY. 11.IN CORRIDORS AND STAIRWELLS, LIGHTING SHALL BE CONTROLLED BY OCCUPANT SENSING CONTROLS THAT SEPARATELY REDUCE THE LIGHTING POWER IN EACH SPACE BY AT LEAST 50 PERCENT WHEN THE SPACE IS UNOCCUPIED. THE OCCUPANT SENSING CONTROLS SHALL BE CAPABLE OF AUTOMATICALLY TURNING THE LIGHTING FULLY ON ONLY IN THE SEPARATELY CONTROLLED SPACE, AND SHALL BE AUTOMATICALLY ACTIVATED FROM ALL DESIGNED PATHS OF EGRESS. [2022 CENC 130.1(C)(6)(C)] 12.TIME CLOCK SHALL INCORPORATE A MANUAL OVERRIDE LIGHTING CONTROL THAT COMPLIES WITH SECTION 130.1(A); AND ALLOWS THE LIGHTING TO REMAIN ON FOR NO MORE THAN 2 HOURS WHEN AN OVERRIDE IS INITIATED; AND SHALL INCORPORATE AN AUTOMATIC HOLIDAY "SHUT-OFF" FEATURE THAT TURNS OFF ALL LOADS FOR AT LEAST 24 HOURS, AND THEN RESUMES THE NORMALLY SCHEDULED OPERATION. [2022 CENC 130.1(C)(3)&(4)] PATIO KEY PLAN SCOPE OF WORK 108 OUTDOOR DINING PATIO 106 MEN'S RR 105 WOMEN'S RR 104 STORAGE 101 DINNING AREA 107 KITCHEN AREA 103 HALLWAY 102 SERVICE AREA X1 L2 L2 L2 L2 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3 L3L3L3 L3L3L3 L3L3L3 X 1 WP SIGNAGE J 4 A-3 EM 1 EM 1 EM1 OS OS 33 L1 EM 1 EM 1 X1 X 1 OS D 2 Dim a,b A-1 Dim a1 A-1 Dim a2 A-1 Dim a3 A-1 Dim a4 A-1 Dim b1 A-1 Dim b2 A-1 Dim b3 D A-1 A-1 EM 1 A-1 A-1 OS EE L1L1 L1 L1 L1 EE 2 EF 1 EF 15'-3" RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 2:42:54 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 E100 1/4" = 1'-0" LIGHTING PLAN J.L.K.P. UP 18x36 18x60 18 x 2 4 A.03 18x54 18 x 3 6 18 x 3 6 4 T I E R 4 T I E R 4 TIER BBAA 4 T I E R 4 TIER 4 TIER GENERAL NOTES: POWER PLAN 1.ELECTRICAL EQUIPMENT SHALL BE LISTED BY U.L. OR CITY RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE CITY DEPARTMENT. 2.ALL ELECTRICAL WORK SHALL COMPLY WITH THE [2022 CEC]. 3.WIRE SIZE SHALL NOT BE LESS THAN CORRESPONDING CIRCUIT BREAKER RATING AS REQUIRED. [2022 CEC TABLE 310.16] 4.CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE [2022 CEC ANNEX C]. 5.CONTRACTOR/ELECTRICIAN TO FIELD VERIFY ACTUAL SITE CONDITION /EXACT SERVICE ENTRANCE AND SHALL NOTIFY EOR(S) ANY DISCREPANCY WITH THE PLAN PRIOR TO BIDDING. 6.ALL ITEMS LABELED/IDENTIFIED AS EXISTING (IF ANY) ARE SUBJECT TO FIELD VERIFICATION. VERIFY EXISTING CONDITION AND RE-USE. IF NOT EXISTING, PROVIDE PER PLAN. 7.COORDINATE LOCATIONS/HEIGHTS OF RECEPTACLES FOR ELECTRICAL DEVICES WITH ARCHITECT AND EQUIPMENT VENDER PRIOR TO ROUGH-IN. 8.ALL NEW ELECTRICAL EQUIPMENT (IF ANY) DIMENSIONS TO BE VERIFIED WITH EQUIPMENT MANUFACTURER/VENDER PRIOR TO PURCHASE. 9.GFCI PROTECTION: ALL 125V THROUGH 250V RECEPTACLES SUPPLIED BY 1-PHASE BRANCH CIRCUITS, 50 AMPERES OR LESS, AND ALL RECEPTACLES SUPPLIED BY 3-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS, INSTALLED IN THE FOLLOWING LOCATIONS SHALL HAVE GFCI PROTECTION FOR PERSONNEL. [2022 CEC 210.8(B)] A.BATHROOMS B.KITCHENS OR AREAS WITH A SINK AND PREM. PROVISION FOR COOKING C.ROOFTOPS/OUTDOORS D.SINKS - WITHIN 6FT FROM THE TOP INSIDE EDGE OF THE SINK E.GARAGES, UNFINISHED AREAS OF BASEMENTS OR SIMILAR AREAS 10.FOR ALL PERMANENTLY CONNECTED APPLIANCES RATED OVER 300VA, THE CIRCUIT BREAKER CAPABLE OF BEING LOCKED IN THE OPEN POSITION SHALL BE PROVIDED UNLESS LOCATION OF THE BREAKER IS WITHIN THE SIGHT OR SEPARATE DISCONNECTING MEANS IS PROVIDED. [2022 CEC 110.25, 422.31(B)] 11.VERIFY ALL KITCHEN EQUIPMENT (IF ANY) INSTALLATION REQUIREMENTS AND POWER CONNECTION TYPE WITH KITCHEN EQUIPMENT SUPPLIER AND MANUFACTURER SPEC SHEET PRIOR TO ROUGH-IN. 1 PANEL "A" T C A-51 (TYP.) SHOW WINDOWA-7 A-9 S M J A-4 (REMOTE AREA - BLDG ELEC. ROOM) METER DIST. P.S. MAIN METER DIST. METER DIST. METER DIST. MAIN SWITCHBOARD "MSA3" 1 HVAC SYSTEM CONNECTION SCHEDULE EQUIPMENT CIRCUIT DESIGNATION VOLT/PHASE FEEDER DISCONNECT MAU-1 A-6/8/10 208V/3PH 4#12, #12GND- 3/4"C 15AF/30AS/3P MECHANICAL EQUIPMENT NOTES: 1.PROVIDE OVERCURRENT PROTECTION AND BRANCH CIRCUITS PER UL LISTED REQUIREMENTS FOR EQUIPMENT SERVED. REFER TO MANUFACTURER DATA AND EQUIPMENT CUT-SHEETS FOR ROUGH-IN LOCATIONS OF ELECTRICAL CONNECTIONS AND INTERCONNECTIONS FOR ALL EQUIPMENT. COORDINATE EXACT NAMEPLATE DATA OF EQUIPMENT BEING INSTALLED WITH MECHANICAL CONTRACTOR. 2.SWITCHES USED AS DISCONNECTING MEANS SHALL BE LOCATED WITHIN SIGHT OF EQUIPMENT. PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. NON-FUSED DISCONNECT IS ACCEPTABLE INSTEAD OF SPECIFIED FUSE TYPE. 3.ADJUST SIZE OF CONDUCTORS AS NEEDED COMPENSATE FOR VOLTAGE DROP. VOLTAGE DROP SHALL NOT EXCEED 3% FOR BRANCH CIRCUITS. 4.REFER TO MECHANICAL PLAN FOR MORE INFO. 5.IF EXISTING UNITS ARE RE-USED, EXISTING DISCONNECT/FUSE/BREAKER TO BE RE-USED OR REPLACED WITH SAME RATING. VERIFY EXISTING CONDITION IN FIELD. DNUP 95.5000 131.0000 126.0000 109.7500 82.0000 58.0000 189.0003 77.0000 83.0000 457.0000 180.0000 5.9373FIRE AREA 1 - W2 30.1873FIRE AREA 4 - W2 11.1632 KEY PLAN SCOPE OF WORK ELECTRICAL ROOM A-11 5 A-13 A-17 10A-19 16 J 22 A-21 21 A-27 A-29 A-2 KEYED PLAN NOTES:# 1.VERIFY/COORDINATE EXACT LOCATION FOR ELECTRICAL EQUIPMENTS AND PROVIDE/MAINTAIN MINIMUM CLEARANCE. [2022 CEC 110.26] 2.CONTRACTOR/ELECTRICIAN TO VERIFY INSTALLATION REQUIREMENTS WITH EQUIPMENT VENDER OR MANUFACTURER PRIOR TO INSTALLATION, AND PROVIDE PER INSTALLATION MANUAL/RECOMMENDATION. 3.REFER TO MECHANICAL PLAN AND HVAC SYSTEM CONNECTION SCHEDULE FOR EXACT LOCATIONS, SPECS AND INSTALLATION REQUIREMENTS. JA-28/30/32 #2 2 3 WH AI R F L O W . AI R F L O W . (A B O V E C E I L I N G ) 1 MAU 26 A-20 27 A-22 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 2:42:57 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 E200 1/4" = 1'-0" POWER PLAN J.L.K.P. HVAC SYSTEM CONNECTION SCHEDULE EQUIPMENT CIRCUIT DESIGNATION VOLT/PHASE FEEDER DISCONNECT KEF-1 A-12/14/16 208V/3PH 4#10, #10GND- 3/4"C 30AF/30AS/3P MECHANICAL EQUIPMENT NOTES: 1.PROVIDE OVERCURRENT PROTECTION AND BRANCH CIRCUITS PER UL LISTED REQUIREMENTS FOR EQUIPMENT SERVED. REFER TO MANUFACTURER DATA AND EQUIPMENT CUT-SHEETS FOR ROUGH-IN LOCATIONS OF ELECTRICAL CONNECTIONS AND INTERCONNECTIONS FOR ALL EQUIPMENT. COORDINATE EXACT NAMEPLATE DATA OF EQUIPMENT BEING INSTALLED WITH MECHANICAL CONTRACTOR. 2.SWITCHES USED AS DISCONNECTING MEANS SHALL BE LOCATED WITHIN SIGHT OF EQUIPMENT. PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. NON-FUSED DISCONNECT IS ACCEPTABLE INSTEAD OF SPECIFIED FUSE TYPE. 3.ADJUST SIZE OF CONDUCTORS AS NEEDED COMPENSATE FOR VOLTAGE DROP. VOLTAGE DROP SHALL NOT EXCEED 3% FOR BRANCH CIRCUITS. 4.REFER TO MECHANICAL PLAN FOR MORE INFO. 5.IF EXISTING UNITS ARE RE-USED, EXISTING DISCONNECT/FUSE/BREAKER TO BE RE-USED OR REPLACED WITH SAME RATING. VERIFY EXISTING CONDITION IN FIELD. POWER PLAN - ROOF DN 6'6' 6' DN KEY PLAN - ROOF KEF-1 LOCATION KEYED PLAN NOTES:# GENERAL NOTES: 1.PROVIDE GFCI/WATERPROOF/WEATHER RESISTANT RECEPTACLE WITHIN 25FT OF HEATING, AC, AND REFRIGERATION EQUIPMENT. 2.REFER TO MECHANICAL PLAN AND HVAC SYSTEM CONNECTION SCHEDULE FOR EXACT LOCATIONS, SPECS AND INSTALLATION REQUIREMENTS. 1.ELECTRICAL EQUIPMENT SHALL BE LISTED BY U.L. OR CITY RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE CITY DEPARTMENT. 2.ALL ELECTRICAL WORK SHALL COMPLY WITH THE [2022 CEC]. 3.WIRE SIZE SHALL NOT BE LESS THAN CORRESPONDING CIRCUIT BREAKER RATING AS REQUIRED. [2022 CEC TABLE 310.16] 4.CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE [2022 CEC ANNEX C]. 5.CONTRACTOR/ELECTRICIAN TO FIELD VERIFY ACTUAL SITE CONDITION /EXACT SERVICE ENTRANCE AND SHALL NOTIFY EOR(S) ANY DISCREPANCY WITH THE PLAN PRIOR TO BIDDING. 6.ALL ITEMS LABELED/IDENTIFIED AS EXISTING (IF ANY) ARE SUBJECT TO FIELD VERIFICATION. VERIFY EXISTING CONDITION AND RE-USE. IF NOT EXISTING, PROVIDE PER PLAN. 7.COORDINATE LOCATIONS/HEIGHTS OF RECEPTACLES FOR ELECTRICAL DEVICES WITH ARCHITECT AND EQUIPMENT VENDER PRIOR TO ROUGH-IN. 8.ALL NEW ELECTRICAL EQUIPMENT (IF ANY) DIMENSIONS TO BE VERIFIED WITH EQUIPMENT MANUFACTURER/VENDER PRIOR TO PURCHASE. 9.GFCI PROTECTION: ALL 125V THROUGH 250V RECEPTACLES SUPPLIED BY 1-PHASE BRANCH CIRCUITS, 50 AMPERES OR LESS, AND ALL RECEPTACLES SUPPLIED BY 3-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS, INSTALLED IN THE FOLLOWING LOCATIONS SHALL HAVE GFCI PROTECTION FOR PERSONNEL. [2022 CEC 210.8(B)] A.BATHROOMS B.KITCHENS OR AREAS WITH A SINK AND PREM. PROVISION FOR COOKING C.ROOFTOPS/OUTDOORS D.SINKS - WITHIN 6FT FROM THE TOP INSIDE EDGE OF THE SINK E.GARAGES, UNFINISHED AREAS OF BASEMENTS OR SIMILAR AREAS 10.FOR ALL PERMANENTLY CONNECTED APPLIANCES RATED OVER 300VA, THE CIRCUIT BREAKER CAPABLE OF BEING LOCKED IN THE OPEN POSITION SHALL BE PROVIDED UNLESS LOCATION OF THE BREAKER IS WITHIN THE SIGHT OR SEPARATE DISCONNECTING MEANS IS PROVIDED. [2022 CEC 110.25, 422.31(B)] 11.RECEPTACLES OF 15 AND 20 AMPERES, 125 AND 250 VOLTS INSTALLED IN A WET LOCATION SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF (WP) AND IS LISTED/IDENTIFIED AS “EXTRA DUTY”. THE RECEPTACLES SHALL BE GFCI PROTECTED. [CEC 2022 210.8(B)(4), 406.9(B)] WR/WP 1 A-18 ELECTRICAL SUB CONTRACTOR TO RUN 1" CONDUIT FROM THE SUITE PANEL THROUGH THE GREASE DUCT SHAFT AND SEAL ALL PENETRATIONS TO ENSURE CODE COMPLIANCE. THE ACCESS PANELS ON EACH FLOOR TO BE UTILIZED FOR THE INSTALLATION. 1 KEF 2 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 2:43:00 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 E201 1/4" = 1'-0" POWER PLAN - ROOF J.L.K.P. SHEET INDEX ·EXISTING COMMERCIAL TENANT IMPROVEMENT. ·REUSE THE EXISTING HVAC UNITS. ·PROVIDE DUCTWORKS AND AIR DEVICES THROUGHOUT THE SPACE. M000 M001 M002 M100 M101 TM00 MECHANICAL NOTES MECHANICAL SCHEDULES MECHANICAL DETAILS MECHANICAL PLAN - ROOF PLAN MECHANICAL TITLE 24 - 1 TM01 MECHANICAL PLAN MECHANICAL TITLE 24 - 2 M200 HOOD INFORMATION M201 HOOD INFORMATION M202 HOOD INFORMATION M203 HOOD INFORMATION M204 HOOD INFORMATION M205 HOOD INFORMATION M206 HOOD INFORMATION SYMBOLS AND ABBREVIATIONS T RETURN AIR PLENUM CROSS-SECTION SUPPLY AIR PLENUM CROSS-SECTION EXHAUST AIR CUBIC FEET PER MINUTE EXTERNAL STATIC PRESSURE SIDE WALL RETURN GRILLE THERMOSTAT SUPPLY DIFFUSER SIDE WALL SUPPLY REGISTER RETURN AIR GRILLE EXHAUST AIR GRILLE / CEILING EXHAUST FAN ESP CFM EA EXISTING FIRE DAMPER HORSEPOWER HERTZ RETURN AIR TYPICAL SUPPLY AIR MANUAL VOLUME DAMPER OUTSIDE SUPPLY AIR SMOKE DETECTOR STATIC PRESSURE FULL LOAD AMPERES VOLT UNDERCUT DOOR UP THRU ROOF MVD V TYP U.T.R. SD SA SP RA OSA FLA HP HZ EXIST FD SD NOTE: REFER TO PLAN SHEETS FOR ANY ADDITIONAL LEGEND, SYMBOLS AND RELATED ABBREVIATIONS. D U S SENSOR EF (E) ROOF MOUNTED EXHAUST FAN NEWNEW(N) U/C CO2 SENSORCO2 1 RTU MECHANICAL EQUIPMENT TAG POC NEW DUCT EXISTING DUCT CONDENSATE DRAINCD REFRIGERANT LINEREF OSA INTAKE OSA DUCTOSA FD CO SENSORCO FIRE SMOKE DAMPERFSDFSD ABBR.SYMBOL DESCRIPTION CONDENSATE DRAIN CLEANOUT HVAC SPECIFICATIONS PIPE INSULATION THICKNESS 4. 5. 6. 1. 7. 2. 3. CONCEALED SPACES, CIRCULATION AIR INSULATION OF DUCTS FLUID TEMP. RANGE (°F) CONDUCTIVITY RANGE (BTU-"/HR PER SQFT/°F) INSULATION MEAN RATING TEMP. (°F) NOMINAL PIPE DIAMETER (") INSULATION THICKNESS REQUIRED (") <1 1 TO <1.5 1.5 TO <4 4 TO <8 8 AND LARGER 251-350 350< 201-250 141-200 105-140 40-60 <40 SPACE COOLING SYSTEMS (CHILLED WATER, REFRIGERANT AND BRINE) SPACE HEATING, HOT WATER SYSTEMS AND SERVICE WATER HEATING SYSTEMS 0.32-0.34 0.29-0.31 0.27-0.30 0.25-0.29 0.22-0.28 0.21-0.27 0.20-0.26 250 200 150 125 100 75 50 4.5 3.0 2.5 1.5 1.0 1.0 5.0 4.0 2.5 1.5 1.5 1.5 5.0 4.5 2.5 2.0 1.5 1.5 5.0 4.5 3.0 2.0 1.5 1.5 5.0 4.5 3.0 2.0 1.5 1.5 A MAINTENANCE LABEL SHALL BE AFFIXED TO MECHANICAL EQUIPMENT AND A MAINTENANCE MANUAL SHALL BE PROVIDED TO THE OWNER PER STANDARDS. EXCEPT AS ALLOWED, THESE CONTROLS SHALL BE ADJUSTABLE TO PROVIDE A DEAD BAND OF 5 DEGREES F BETWEEN FULL HEATING AND FULL COOLING. CONTROLS SHALL HAVE THE CAPABILITY OF TERMINATING ALL HEATING AT A TEMPERATURE NO MORE THAN 70 DEGREES F AND OF TERMINATING ALL COOLING AT A TEMPERATURE NOT LESS THAN 78 DEGREES F. EACH HVAC SYSTEM SHALL BE PROVIDED WITH AT LEAST ONE AUTOMATIC TEMPERATURE CONTROL DEVICE FOR THE REGULATION OF TEMPERATURE THESE AUTOMATIC TEMPERATURE CONTROL DEVICES SHALL BE CAPABLE OF BEING SET TO MAINTAIN SPACE TEMPERATURE SET POINTS FROM 55 DEGREES F TO 85 DEGREES F, SHALL BE CAPABLE OF OPERATING THE SYSTEM HEATING AND/OR COOLING IN SEQUENCE. EXCEPTIONS: (1)FACTORY-INSTALLED PIPING WITHIN SPACE CONDITIONING EQUIPMENT; (2)PIPING THAT CONVEYS FLUIDS THAT HAVE A DESIGN OPERATING TEMPERATURE RANGE BETWEEN 60 DEGREES AND 105 DEGREES FAHRENHEIT; (3)WHERE THE HEAT GAIN OR HEAT LOSS TO OR FROM PIPING WITHOUT INSULATION WILL NOT INCREASE BUILDING SOURCE ENERGY USE; (4)PIPING THAT PENETRATES FRAMING MEMBERS SHALL NOT BE REQUIRED TO HAVE PIPE INSULATION FOR THE DISTANCE OF THE FRAMING PENETRATION. METAL PIPING THAT PENETRATES METAL FRAMING SHALL USE GROMMETS, PLUGS, WRAPPING OR OTHER INSULATING MATERIAL TO ASSURE THAT NO CONTACT IS MADE WITH THE METAL FRAMING. INSPECTION TO BE MADE AND DUCTWORK APPROVED BEFORE COVERING WITH INSULATION. TRANSVERSE SUPPLY DUCTS, TAPED OR SEALED WITH MASTIC EXCEPT FOR DUCTS EXPOSED TO CONDITIONED SPACE, WHERE DUCT STATIC PRESSURE EXCEEDS 3/4" WATER, LONGITUDINAL JOINTS, TAPED OR SEALED WITH MASTIC. SEALING INSPECTION PIPE INSULATION SPACE-CONDITIONING AND SERVICE WATER-HEATING SYSTEM SHALL BE INSULATED IN ACCORDANCE WITH THE FOLLOWING TABLE: INSULATED WIRES, PLASTIC TUBING OR PIPING, PIPE INSULATION, CONDENSATE PAN INSULATION, WOOD, PVC, ABS AND OTHER PLASTICS) TO BE IN CONCEALED SPACES USED TO CONVEY CIRCULATING AIR SUPPLY. WHEN COMBUSTIBLE MATERIAL IS TO BE LOCATED IN THE ABOVE SPACES, IT SHALL BE APPROVED FOR SUCH INSULATION. TEMPERATURE CONTROLS PORTIONS OF SUPPLY-AIR AND RETURN-AIR DUCTS CONVEYING HEATED OR COOLED AIR LOCATED IN ONE OR MORE OF THE FOLLOWING SPACES SHALL BE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-8: 1.OUTDOORS; OR 2.IN A SPACE BETWEEN THE ROOF AND AN INSULATED CEILING; OR 3.IN A SPACE DIRECTLY UNDER A ROOF WITH FIXED VENTS OR OPENINGS TO THE OUTSIDE OR UNCONDITIONED SPACES; OR 4.IN AN UNCONDITIONED CRAWL SPACE; OR 5.IN OTHER UNCONDITIONED SPACES. PORTIONS OF SUPPLY-AIR DUCTS THAT ARE NOT IN ONE OF THESE SPACES, INCLUDING DUCTS BURIED IN CONCRETE SLAB, SHALL BE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-4.2 OR BE ENCLOSED IN DIRECTLY CONDITIONED SPACE. NONRES 0.5 RES 0.75 1.01.0 1.0 1.ALL WORK SHALL CONFORM TO MECHANICAL CODE, BUILDING CODE AND ALL OTHER APPLICABLE CITY CODES AND REGULATIONS. 2.THE CONTRACTOR SHALL PAY FOR ALL PERMITS AND FEES. 3.CONTROL LOW VOLTAGE WIRING BY MECHANICAL CONTRACTOR AND CONDUIT BY ELECTRICAL CONTRACTOR. 4.CONDENSATE DRAIN PIPING AND FINAL CONNECTION TO UNIT BY PLUMBING CONTRACTOR. 5.G.C. TO VERIFY CURRENT ELECTRICAL POWER CONDITION IN FIELD BEFORE PURCHASING ANY MECHANICAL EQUIPMENT. 6.CONTRACTOR TO VERIFY MECHANICAL HEATING EQUIPMENT TO BE CONFORM TO LOCAL EPA STANDARD BEFORE PURCHASING EQUIPMENT. 7.ACCURATE AS-BUILT DRAWINGS SHALL BE MADE DURING CONSTRUCTION AND SUBMITTED FOR APPROVAL UPON COMPLETION OF INSTALLATION. 8.THE CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR FOR SIZE AND LOCATION OF DUCTWORK ROOF OPENINGS AND WITH ELECTRICAL CONTRACTOR FOR ELECTRICAL REQUIREMENTS OF ALL MECHANICAL EQUIPMENT AND ARCHITECTURAL DRAWINGS FOR AIR DISTRIBUTION LOCATION. 9.THE CONTRACTOR SHALL SUBMIT BID BASED ON THE DRAWINGS AND ALTERNATE FOR COST SAVING. THESE DRAWINGS ARE FOR BIDDING PURPOSES. 10.THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR, EQUIPMENT, TRANSPORTATION AND SERVICES NECESSARY FOR COMPLETION OF THE WORK. ALL MATERIALS AND WORK SHALL COMPLY WITH APPLICABLE CODES AND GOVERNING REGULATIONS AND MEET THE APPROVAL OF THE LOCAL JURISDICTION. 11.TAKE ALL PRECAUTIONS NECESSARY TO PROTECT THE MATERIALS BEFORE, DURING AND AFTER INSTALLATION. IN THE EVENT OF DAMAGE, IMMEDIATELY REPAIR ALL DAMAGED AND DEFECTIVE WORK TO THE APPROVAL OF THE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 12.THESE DRAWINGS ARE DIAGRAMMATIC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH ALL OTHER TRADES. THIS INCLUDES COORDINATING THE LOCATION AND SIZE OF ALL OPENINGS, LOCATIONS OF EQUIPMENT PADS AND CHANGES OF ELEVATIONS OF DUCTWORK, PIPING AND OTHER EQUIPMENT. 13.ANY MATERIAL, ARTICLE OR PIECE OF EQUIPMENT OTHER THAN THAT INDICATED SHALL NOT BE USED UNLESS APPROVED IN WRITING BY THE ENGINEER AND ANY CHANGES IN MECHANICAL, ELECTRICAL AND/OR OTHER SYSTEMS REQUIRED DUE TO SUCH SUBSTITUTION SHALL BE THE RESPONSIBILITY OF THE HVAC CONTRACTOR; AND AT NO ADDITIONAL COST TO THE OWNER. 14.THE CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING TO VERIFY LOCATIONS AND SIZES OF ALL EXISTING EQUIPMENT AND INFORM THE ARCHITECT AND ENGINEER OF ANY DISCREPANCIES. 15.CONTRACTOR TO VERIFY ADEQUATE PLUMBING CONNECTIONS ARE READILY AVAILABLE FOR EVAPORATIVE COOLERS AND GAS HEATING SYSTEMS BEFORE PURCHASING EQUIPMENT. 16.COORDINATE ENTIRE INSTALLATION OF THE H.V.A.C. SYSTEM WITH THE WORK OF ALL OTHER TRADES PRIOR TO ANY FABRICATION OR INSTALLATION. PROVIDE ALL FITTINGS, OFFSETS, AND TRANSITIONS AS REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 17.WARRANTIES; 1-YEAR WARRANTY FOR EQUIPMENT, 5-YEAR COMPRESSORS. REFER TO CONSTRUCTION CONTRACT FOR OTHER APPLICABLE WARRANTIES. 18.EQUIPMENT SPECIFICATION AND INTERLOCK DIAGRAM SHALL BE SUBMITTED FOR APPROVAL PRIOR TO PURCHASE OF EQUIPMENT FOR INSTALLATION. 19.ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL FITTINGS, TRANSITIONS, DAMPERS, VALVES AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 20.HEATING, VENTILATING, AND AIR-CONDITIONING SYSTEMS SHALL BE BALANCED BY A LICENSED T&B CONTRACTOR IN ACCORDANCE WITH ONE OF THE FOLLOWING METHODS (CMC 314.1): ·AABC NATIONAL STANDARDS FOR TOTAL SYSTEM BALANCE ·ACCA MANUAL B ·ASHRAE 111 ·NEBB PROCEDURAL STANDARDS FOR TESTING ADJUSTING BALANCING OF ENVIRONMENTAL SYSTEMS ·SMACNA HVAC SYSTEMS TESTING, ADJUSTING AND BALANCING 21.PROVIDE FILTER FOR AIR CONDITIONING AND/OR AIR SIDE UNITS AS REQUIRED PER ASHRAE AND MECHANICAL CODE. 22.THERMOSTAT SHALL BE 24 VOLT, ONE STAGE HEATING AND ONE OR TWO STAGE COOLING WITH MATCHING SUBBASE AND TAMPER PROOF COVER. 23.CONDENSATE PIPING SHALL BE SIZED IN ACCORDANCE WITH MECHANICAL CODE. 24.AUTOMATIC FIRE DAMPER REQUIREMENTS ARE AS FOLLOWS: a.PROVIDE AUTOMATIC FIRE DAMPERS AT ALL PENETRATIONS OF FIRE-RATED CEILINGS AND WALLS THROUGHOUT. CONTRACTOR SHALL COORDINATE WITH FIRE-RATED CEILING AREAS AND WALLS AS INDICATED ON ARCHITECTURAL DRAWINGS. THIS NOTE SHALL TAKE PRECEDENCE OVER ANY OMISSIONS ON THE DRAWINGS. SEE SPECIFICATIONS. b.LOCATION OF FIRE-RATED CEILINGS AND WALLS ARE AS INDICATED ON THE ARCHITECTURAL DRAWINGS. CA GREEN BUILDING NOTES HVAC GENERAL NOTES MECHANICAL CODE ·2022 CALIFORNIA MECHANICAL CODE ·2022 CALIFORNIA ENERGY CODE 26.CONDENSATE WASTE SHALL CONNECT INDIRECTLY TO THE DRAINAGE SYSTEM THROUGH AN AIR GAP OR AIR BREAK TO PROPERLY TRAPPED AND VENTED RECEPTORS, DRY WELLS, OR THE TAILPIECE OF A PLUMBING FIXTURE. 27.WHERE CONDENSATE WASTE FROM AIR CONDITIONING COILS DISCHARGES BY DIRECT CONNECTION TO A LAVATORY TAILPIECE OR TO AN APPROVED ACCESSIBLE INLET ON A BATHTUB OVERFLOW, THE CONNECTION SHALL BE LOCATED IN AN AREA CONTROLLED BY THE SAME PERSON CONTROLLING THE AIR-CONDITIONED SPACE. 28.THE REFRIGERATION EQUIPMENT REFRIGERANT SERVICE PORTS LOCATED OUTDOORS SHALL BE FITTED WITH LOCKING TYPE TAMPER RESISTANT CAPS OR SHALL BE PROTECTED FROM UNAUTHORIZED ACCESS BY A MEANS ACCEPTABLE TO THE ENFORCING AGENCY. 29.THE HEATING AND COOLING DUCT SYSTEM IS SIZED IN ACCORDANCE WITH ASHRAE. 30.G.C. TO VERIFY SUFFICIENCY OF DUCT SPACE BEFORE PURCHASING ANY MECHANICAL EQUIPMENT. 31.DUCTWORK SHALL BE INSULATED OR LINED AS NOTED ON DRAWINGS. ALL DUCTWORK EXPOSED ON ROOF SHALL BE INTERNALLY LINED UNLESS OTHERWISE INDICATED OR SPECIFIED. ALL DUCT SIZES ARE SHEET METAL SIZES. ALL DUCT JOINTS SHALL BE SEALED PER SPECIFICATIONS. 32.CONNECT MAIN DUCT TO AIR CONDITIONING UNIT WITH WEATHERPROOF FLEXIBLE CONNECTION. SUN SHIELD OVER ENTIRE FLEXIBLE CONNECTIONS REQUIRED IF FLEXIBLE CONNECTION IS EXPOSED TO WEATHER. 33.ALL LINED DUCT DIMENSIONS ARE NET CLEAR DIMENSION AFTER LINING HAS BEEN INSTALLED. 34.ALL DUCTWORK SIZE SHOWN ON PLAN ARE INTERIOR DIAMETER. CONTRACTOR SHALL ADD INSULATION THICKNESS INTO CONSIDERATION BEFORE INSTALLATION. 35.DUCTS SHALL BE SUPPORTED WITH 1" WIDE 16-GAUGE HANGER STRAPS AND SHALL BE SPACED AT NO MORE THAN 7'-0" ON CENTERS AND SHALL BE SECURED TO STRUCTURAL MEMBER. EXPOSED DUCTWORK ON ROOF SHALL BE SUPPORTED BY GALVANIZED STEEL ANGLE & SHALL BE PER LOCAL CODE. 36.ROUND AND RECTANGULAR DUCTWORK ARE INTERCHANGEABLE IF CROSS SECTION AREAS ARE EQUIVALENT. CONTRACTOR IS TO VERIFY THE EXACT CEILING SPACE AND INTERCHANGE THE DUCT SIZE TO FIT THE CEILING SPACE WITHOUT ADDITIONAL FEE CHARGE. 37.ALL FACTORY-FABRICATED DUCT SYSTEMS SHALL COMPLY WITH UL 181 FOR DUCTS AND CLOSURE SYSTEMS, INCLUDING COLLARS, CONNECTIONS, AND SPLICES, AND BE LABELED AS COMPLYING WITH UL 181. 38.INSTALL VOLUME CONTROL DAMPERS AT EACH SUPPLY DIFFUSER TO AFFORD COMPLETE CONTROL OF THE AIR FLOW IN THE VARIOUS DUCT SYSTEMS. INSTALL SPLITTER DAMPER AT DUCT TAKEOFFS AND DAMPER AS REQUIRED. 39.COORDINATE THE LOCATION OF ALL CEILING DIFFUSERS, REGISTERS AND GRILLES WITH THE ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL LIGHTING LAYOUT AND ARCHITECTURAL ROOM ELEVATIONS. 40.ALL CEILING DIFFUSERS ARE 4-WAY UNLESS OTHERWISE NOTED. 41.PROVIDE BACK-DRAFT DAMPER FOR ALL EXHAUST AIR DUCT UNLESS OTHERWISE NOTED PER CODE. 42.EXHAUST TERMINATION SHALL BE MINIMUM 10'-0" AWAY OR 3'-0" ABOVE FROM ANY FRESH AIR INTAKE, OPERABLE WINDOWS, DOORS AND 10'-0" MINIMUM ABOVE GRADE. 43.PROVIDE ALL FRESH AIR INTAKES AND EXHAUST OUTLETS WITH HOOD, 1/2" GALVANIZED MESH SCREENS AND OUTSIDE AIR BACK-DRAFT DAMPERS. 44.ALL HVAC UNITS OR SYSTEMS SERVING A COMMON AIR SPACE MUST BE INTERCONNECTED TO SHUT DOWN IMMEDIATELY UPON ALARM CONDITION FROM DUCT DETECTORS (OR FIRE ALARM SYSTEM WHEN USING AREA SMOKE DETECTORS IN LIEU OF DUCT DETECTORS) WITHOUT INTERFERENCE FROM EMS OR ANY OTHER SYSTEMS. ALL CONTROL RELAYS USED FOR SHUT DOWN MUST BE APPROVED BY STATE OR LOCAL JURISDICTION FOR RELEASING SERVICE. 45.PURCHASING PARTY SHALL ENSURE THE MOTOR SPECS PRIOR TO ORDERING EXHAUST SYSTEM TO ENSURE THE PANEL IS BUILT CORRECTLY. 46.REDWOOD SLEEPER OR PLATFORM FOR ROOF MOUNTED UNIT, DUCT PENETRATION, CUTTING AND PATCHING BY GENERAL CONTRACTOR, UNLESS OTHERWISE NOTED ON PLAN. 47.42" MINIMUM GUARDS TO BE PROVIDED WHEN ROOF MOUNTED OR ROOF ACCESS EQUIPMENT THAT REQUIRE SERVICE ARE LOCATED WITHIN 10' OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30" ABOVE THE ROOF SURFACE. 48.CONTRACTOR SHALL SUBMIT A COMPLETE BALANCE REPORT FOR APPROVAL. SYSTEMS AIR BALANCE SHALL BE PERFORMED BY AN INDEPENDENT AIR BALANCE CONSULTANT. A CERTIFIED AABC OR NEBB. THE REPORT SHALL INCLUDE THE FOLLOWING: a.AIR QUANTITIES AT EACH REGISTER. b.STATIC PRESSURE READINGS AT INLET AND DISCHARGE OF EACH AIR HANDLING SYSTEM AND AT INLET OF EACH EXHAUST AIR SYSTEM. c.COOLING AND HEATING SUPPLY AND RETURN AIR TEMPERATURES AT EACH AIR CONDITIONING UNIT. 5.504.1 TEMPORARY VENTILATION: IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MERV OF 8, BASED ON ASHRAE 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30% BASED ON ASHRAE 52.1-1992. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY. APPLIES TO ADDITIONS OR ALTERATIONS. 5.504.3 COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION: AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC,SHEET METAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. 5.504.5.3 FILTERS: IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED AREAS OF THE BUILDING WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR PRIOR TO OCCUPANCY THAT PROVIDES AT LEAST A MERV OF 13. 5.506.1 OUTSIDE AIR DELIVERY: FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM REQUIREMENTS OF SECTION 120.1 OF THE CALIFORNIA ENERGY CODE AND CHAPTER 4 OF CCR, TITLE 8, OR THE APPLICABLE LOCAL CODE, WHICHEVER IS MORE STRINGENT. 5.508.1.1.CHLOROFLUOROCARBONS ( CFCs): INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THAT DO NOT CONTAIN CFCs. 5.508.1.2.HALONS: INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THAT DO NOT CONTAIN HALONS. ADIMINISTRATIVE REQUIREMENTS: A.THE PERSON WITH OVERALL RESPONSIBILITY FOR CONSTRUCTION OR THE PERSON RESPONSIBLE FOR THE INSTALLATION OF REGULATED FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES SHALL POST, OR MAKE AVAILABLE WITH THE BUILDING PERMIT(S) ISSUED FOR THE BUILDING, THE REQUIRED INSTALLATION CERTIFICATE(S) FOR FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES REGULATED BY THE APPLIANCE EFFICIENCY REGULATIONS OR PART 6. SUCH INSTALLATION CERTIFICATE(S) SHALL BE MADE AVAILABLE TO THE ENFORCEMENT AGENCY FOR ALL APPROPRIATE INSPECTIONS. THESE CERTIFICATES SHALL: A.1.IDENTIFY FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES REQUIRED TO VERIFY COMPLIANCE WITH THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6. A.2.INCLUDE A STATEMENT INDICATING THAT THE FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVISE CONFORM TO THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6 AND THE REQUIREMENTS FOR SUCH FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES GIVEN IN THE PLANS AND SPECIFICATIONS APPROVED BY THE LOCAL ENFORCEMENT AGENCY. A.3.STATE THE NUMBER OF THE BUILDING PERMIT UNDER WHICH THE CONSTRUCTION OR INSTALLATION WAS PERFORMED. B.WITHIN 90 DAYS AFTER ISSUANCE OF CERTIFICATE OF OCCUPANCY RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER. IF A BUILDING DESIGN FEATURE, MATERIAL, COMPONENT OR MANUFACTURED DEVICE IS CHANGED BEFORE FINAL CONSTRUCTION AND INSTALLATION, SUCH THAT THE BUILDING MAY NO LONGER COMPLY WITH PART 6, THE BUILDING MUST BE BROUGHT INTO COMPLIANCE, AND SO INDICATED ON AMENDED PLANS AND CERTIFICATE OF COMPLIANCE(S) THAT SHALL BE SUBMITTED FOR APPROVAL. C.THE BUILDER SHALL PROVIDE THE BUILDING OWNER OR THE PERSON(S) RESPONSIBLE FOR BUILDING MAINTENANCE (IN CASE OF MULTI-TENANT OR CENTRALLY OPERATED BUILDINGS) AT OCCUPANCY THE FOLLOWING: C.1.OPERATING INFORMATION: THE APPROPRIATE CERTIFICATE(S) OF COMPLIANCE AND A LIST OF THE FEATURES, MATERIALS, COMPONENTS, AND MECHANICAL DEVICES INSTALLED IN THE BUILDING AND INSTRUCTIONS ON HOW TO OPERATE THEM EFFICIENTLY. C.2.MAINTENANCE INFORMATION: REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING THE OPERATION AND MAINTENANCE MANUAL. C.3.VENTILATION INFORMATION: A DESCRIPTION OF THE QUANTITIES OF OUTDOOR AND RECIRCULATED AIR THAT THE VENTILATION SYSTEMS ARE DESIGNED TO PROVIDE TO EACH AREA. MANDATORY MEASURES: A.(IF APPLICABLE) MANUFACTURED FENESTRATION AND EXTERIOR DOORS SHALL MEET ALL LISTED REQUIREMENTS IN SEC 10-111-(A) UNDER SECTION 110.6(A) OF PART 6. TEMPORARY LABELS FOR MANUFACTURED FENESTRATION SHALL HAVE A CLEARLY VISIBLE TEMPORARY LABEL AND SHALL COMPLY WITH LABELING REQUIREMENTS OF NFRC 700. NO OTHER VALUES FOR U-FACTOR, SHGC, VT AND AIR LEAKAGE ARE ALLOWED ON THE TEMPORARY LABEL ATTACHED TO THE MANUFACTURED FENESTRATION PRODUCT OR EXTERIOR DOOR. B.(IF APPLICABLE) RATED FENESTRATION SHALL HAVE A PERMANENT LABEL CONSISTENT WITH THEIR RATING AND CERTIFICATION THAT IS EITHER A STAND-ALONE LABEL, AN EXTENSION OR TAB OF AN EXISTING PERMANENT CERTIFICATION LABEL BEING USED BY THE MANUFACTURER/RESPONSIBLE PARTY, OR A SERIES OF MARKS OR ETCHINGS ON THE PRODUCT. C.JOINTS, PENETRATIONS AND OTHER OPENINGS IN THE BUILDING ENVELOPE THAT ARE POTENTIAL SOURCES OF AIR LEAKAGE SHALL BE CAULKED, GASKETED, WEATHER STRIPPED, OR OTHERWISE SEALED TO LIMIT INFILTRATION AND EXFILTRATION. D.ALL INSULATING MATERIAL SHALL BE INSTALLED IN COMPLIANCE WITH THE FLAME-SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF THE CBC. E.NON-CENTRALIZED ENERGY MANAGEMENT SYSTEMS SHALL HAVE SETBACK THERMOSTATS; CAPABLE TO PROGRAM TEMPERATURE SETPOINTS FOR AT LEAST FOUR PERIODS WITHIN A 24-HR. PERIOD. F.ALL RECIRCULATED AIR OR OUTDOOR AIR SUPPLIED TO OCCUPIABLE SPACES IS FILTERED (MINIMUM MERV 13) BEFORE PASSING THROUGH ANY AIR CONDITIONING COMPONENT; THE LESSER OF THE MINIMUM RATE OF OUTDOOR AIR REQUIRED BY SEC. 120.1 (C), OR THREE COMPLETE AIR CHANGES SHALL BE SUPPLIED TO THE ENTIRE BUILDING DURING THE ONE-HOUR PERIOD IMMEDIATELY BEFORE THE BUILDING IS NORMALLY OCCUPIED. G.ALL MECHANICAL VENTILATION AND SPACE-CONDITIONING SYSTEMS SHALL BE DESIGNED WITH DUCTWORK, DAMPERS, AND CONTROLS WHICH ALLOWS OUTSIDE AIR RATES TO BE OPERATED AT THE LARGER OF (1) THE MINIMUM LEVELS SPECIFIED IN SECTION 120.1(C)3 OR (2) THE RATE REQUIRED FOR MAKE-UP OF EXHAUST SYSTEMS THAT ARE REQUIRED FOR AN EXEMPT OR COVERED PROCESS, FOR CONTROL OF ODORS, OR FOR THE REMOVAL OF CONTAMINANTS WITHIN THE SPACE. MEASURED OUTSIDE AIR RATES OF CONSTANT AND VARIABLE VOLUME MECHANICAL VENTILATION SYSTEMS SHALL BE WITHIN 10% OF OUTSIDE AIR RATE SHOWN ON TABLE 120.1-A. H.THE THERMOSTATIC CONTROLS FOR HVAC SYSTEMS SHALL BE CAPABLE OF BEING SET LOCALLY OR REMOTELY BY TO CONTROL COMFORT HEATING DOWN TO 55 °F OR LOWER AND COOLING UP TO 85°F OR HIGHER. THE THERMOSTATIC CONTROLS SHALL BE CAPABLE OF PROVIDING A DEAD BAND RANGE OF AT LEAST 5 °F WITHIN WHICH HEATING AND COOLING ENERGY TO THE ZONE IS SHUT OFF OR REDUCE TO A MINIMUM. I.OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL BE INSTALLED WITH DAMPERS THAT AUTOMATICALLY CLOSE UPON FAN SHUTDOWN. J.AIR DISTRIBUTION SYSTEM DUCTS AND PLENUMS, INCLUDING, BUT NOT LIMITED TO, BUILDING CAVITIES, MECHANICAL CLOSETS, AIR-HANDLER BOXES AND SUPPORT PLATFORMS USED AS DUCTS OR PLENUMS, SHALL BE INSTALLED, SEALED AND INSULATED TO MEET THE REQUIREMENTS OF CHAPTER 6 CMC CODE AND ANSI/SMACNA -006-2006 HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE. SUPPLY-AIR DUCTS CONVEYING HEATED OR COOLED AIR SHALL BE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-4.2 (R-8 IN UNCONDITIONED SPACE), UNLESS DUCTS ARE IN CONDITIONED SPACE. K.MAXIMUM LENGTH OF FLEXIBLE DUCT AND CONNECTORS SHALL NOT BE MORE THAN 5 FEET. FLEXIBLE DUCTS SHALL NOT BE USED IN LIEU OF RIGID ELBOWS. L.EACH SPACE-CONDITIONING SYSTEM SHALL BE INSTALLED WITH CONTROLS (1) CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SYSTEM DURING PERIODS OF NON-USE AND SHALL HAVE (A) 4-HR TIMER OR; (B) OCCUPANCY SENSORS OR; (C) AUTO TIME SWITCH CONTROLS AND ACCESSIBLE MANUAL OVERRIDE FOR UP TO 4-HRS. (2) AUTOMATICALLY RESTART AND TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN SETBACK THERMOSTAT SETPOINTS FOR MECHANICAL HEATING AND COOLING. (3) MULTIPURPOSE, CLASSROOMS CONFERENCE, CONVENTION, AUDITORIUM AND MEETING CENTER ROOMS OF CERTAIN SIZE WHICH DO NOT HAVE PROCESSES OR OPERATIONS THAT GENERATE DUSTS, FUMES, VAPORS OR GASSES SHALL BE EQUIPPED WITH OCCUPANT SENSOR(S) TO ACCOMPLISH THE FOLLOWING DURING UNOCCUPIED PERIODS (A) AUTOMATICALLY SETUP THE OPERATING COOLING TEMPERATURE SET POINT BY 2°F OR MORE AND SETBACK THE OPERATING HEATING TEMPERATURE SET POINT BY 2˚F OR MORE AND; (B) AUTOMATICALLY RESET THE MINIMUM REQUIRED VENTILATION RATE WITH AN OCCUPANT SENSOR VENTILATION CONTROL DEVICE ACCORDING TO SECTION 120.1(C)5. (4) HOTEL AND MOTEL GUEST ROOMS SHALL HAVE CAPTIVE CARD KEY CONTROLS, OCCUPANCY SENSING CONTROLS, OR AUTOMATIC CONTROLS SUCH THAT, NO LONGER THAN 30 MINUTES AFTER THE GUEST ROOM HAS BEEN VACATED, SETPOINTS ARE SETUP AT LEAST +5°F (+3°C) IN COOLING MODE AND SET-DOWN AT LEAST -5°F (-3°C) IN HEATING MODE. M.ALL DUCTWORK AND PLENUMS WITH PRESSURE CLASS RATINGS SHALL BE CONSTRUCTED TO SEAL CLASS A. JOINTS AND SEAMS OF DUCT SYSTEMS AND THEIR COMPONENTS SHALL NOT BE SEALED WITH CLOTH-BACK RUBBER ADHESIVE DUCT TAPES UNLESS SUCH TAPE IS USED IN COMBINATION WITH MASTIC AND DRAWBANDS. EXCEPTION TO SECTION 120.4(B)1D: DUCTWORK LOCATED IN OCCUPIED SPACE AND EXPOSED TO VIEW IS NOT REQUIRED TO MEET SEAL CLASS A. CA TITLE 24 NOTES LESS THAN 12 26/.022 .025 13-30 26/.022 .025 31-36 24/.023 .026 FOOTNOTES: FOR GALVANIZED STEEL (SMACNA TABLE 1-4/E5) MAXIMUM 1" W.G. STATIC POSITIVE AND NEGATIVE DUCT GAUGE SELECTIONS MINIMUM THICKNESS ALUMINUM (INCHES) MINIMUM THICKNESS GALVANIZED IRON (U.S. GAUGE/INCHES) DUCT DIAMETER (INCHES) 1. HEATING AND AIR CONDITIONING UNITS NOT EXCEEDING 2000 CFM OR ONE INCH WATER GAUGE (WG) POSITIVE OR NEGATIVE PRESSURE. DUCT FITTINGS SHALL BE CONSTRUCTED OF MATERIAL NOT LESS THAN THE GAUGE OF THE DUCT. 2. DUCTWORK AND FITTINGS LARGER THAN TWENTY INCHES SHALL BE CONSTRUCTED TO THE GAUGING REQUIREMENTS OF ANSI SMACNA 006-2020 HVAC DUCT CONSTRUCTION STANDARDS. CA TITLE 24 NOTES MANDATORY MEASURES: N. DUCT SYSTEMS SHALL COMPLY WITH SUBSECTION 1 OR 2 BELOW: 1.NEW DUCT SYSTEMS THAT MEET THE CRITERIA IN SUBSECTIONS A, B, C AND D BELOW SHALL BE SEALED TO A LEAKAGE RATE NOT TO EXCEED 6 PERCENT OF THE NOMINAL AIR HANDLER AIRFLOW RATE AS CONFIRMED THROUGH HERS FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN ACCORDANCE WITH REFERENCE NONRESIDENTIAL APPENDIX NA7.5.3; N.1.THE DUCT SYSTEM DOES NOT SERVE A HEALTHCARE FACILITY; AND N.2.THE DUCT SYSTEM PROVIDES CONDITIONED AIR TO AN OCCUPIABLE SPACE FOR A CONSTANT VOLUME, SINGLE ZONE, SPACE-CONDITIONING SYSTEM; AND N.3.THE SPACE-CONDITIONING SYSTEM SERVES LESS THAN 5,000 SQUARE FEET OF CONDITIONED FLOOR AREA; AND N.4.THE COMBINED SURFACE AREA OF THE DUCTS LOCATED OUTDOORS OR IN UNCONDITIONED SPACE IS MORE THAN 25 PERCENT OF THE TOTAL SURFACE AREA OF THE ENTIRE DUCT SYSTEM. 2.NEW DUCT SYSTEMS THAT ARE NOT SUBJECT TO TESTING UNDER SECTION 120.4(G)1 SHALL INSTEAD MEET THE DUCT LEAKAGE TESTING REQUIREMENTS OF CMC SECTION 603.9.2. P. OCCUPANT SENSOR VENTILATION CONTROL DEVICES. OCCUPANT SENSING OR VENTILATION CONTROLS ARE REQUIRED FOR SPACE CONDITIONING ZONES THAT ARE BOTH PERMITTED TO HAVE THEIR VENTILATION AIR REDUCED TO ZERO WHILE IN OCCUPIED STANDBY MODE PER TABLE 120.1-A AND REQUIRED TO INSTALL OCCUPANT SENSORS TO COMPLY WITH SECTION 130.1(C)5, 6, AND 7. OCCUPANT SENSOR VENTILATION CONTROL DEVICES USED TO REDUCE THE RATE OF OUTDOOR AIRFLOW WHEN OCCUPANTS ARE NOT PRESENT SHALL COMPLY WITH THE FOLLOWING: P.1.OCCUPANT SENSORS SHALL HAVE SUITABLE COVERAGE AND PLACEMENT TO DETECT OCCUPANTS IN THE ENTIRE SPACE VENTILATED. IN 20 MINUTES OR LESS AFTER NO OCCUPANCY IS DETECTED BY ANY SENSORS COVERING THE ROOM, OCCUPANT SENSING CONTROLS SHALL INDICATE A ROOM IS VACANT. P.2.WHEN OCCUPANT SENSORS CONTROLLING LIGHTING ARE ALSO USED FOR VENTILATION, THE VENTILATION SIGNAL SHALL BE INDEPENDENT OF DAYLIGHTING, MANUAL LIGHTING OVERRIDES OR MANUAL CONTROL OF LIGHTING. P.3.WHEN A SINGLE ZONE DAMPER OR A SINGLE ZONE SYSTEM SERVES MULTIPLE ROOMS, THERE SHALL BE AN OCCUPANT SENSOR IN EACH ROOM AND THE ZONE SHALL NOT BE CONSIDERED VACANT UNTIL ALL ROOMS IN THE ZONE ARE VACANT. P.4.ONE HOUR PRIOR TO NORMAL SCHEDULED OCCUPANCY, THE OCCUPANT SENSOR VENTILATION CONTROL SHALL ALLOW PRE-OCCUPANCY PURGE AS DESCRIBED IN SECTION 120.1(D)2. P.5.WHEN THE ZONE IS SCHEDULED TO BE OCCUPIED AND OCCUPANT SENSING CONTROLS IN ALL ROOMS AND AREAS SERVED BY THE ZONE INDICATE THE SPACES ARE UNOCCUPIED, THE ZONE SHALL BE PLACED IN OCCUPIED STANDBY MODE. P.6.IN 5 MINUTES OR LESS AFTER ENTERING OCCUPIED-STANDBY MODE, MECHANICAL VENTILATION TO THE ZONE SHALL BE SHUT OFF UNTIL THE SPACE BECOMES OCCUPIED OR UNTIL VENTILATION IS NEEDED TO PROVIDE SPACE HEATING OR CONDITIONING. WHEN MECHANICAL VENTILATION IS SHUT OFF TO THE ZONE, THE VENTILATION SYSTEM SERVING THE ZONE SHALL REDUCE THE SYSTEM OUTSIDE AIR RATE BY THE AMOUNT OF OUTSIDE AIR REQUIRED FOR THE ZONE. P.7.WHERE THE SYSTEM PROVIDING SPACE CONDITIONING ALSO PROVIDES VENTILATION TO THE ZONE, IN 5 MINUTES OR LESS AFTER ENTERING OCCUPIED-STANDBY MODE, SPACE CONDITIONING ZONE SETPOINTS SHALL BE RESET IN ACCORDANCE WITH SECTION 120.2(E)3. SCOPE OF WORK 2022 BUILDING ENERGY EFFICIENCY STANDARDS SECTION 120.1(D)4 A.For each system with demand control ventilation (DCV), CO2 sensors shall be installed in each room that meets the criteria of Section 120.1(d)3 with no less than one sensor per 10,000 ft² of floor space. When a zone or a space is served by more than one sensor, a signal from any sensor indicating that CO2 is near or at the setpoint within the zone or space shall trigger an increase in ventilation. B.CO2 sensors shall be located in the room between 3 ft and 6 ft above the floor or at the anticipated height of the occupants’ heads. C.Demand ventilation controls shall maintain CO2 concentrations less than or equal to 600 ppm plus the outdoor air CO2 concentration in all rooms with CO2 sensors. EXCEPTION to Section 120.1(d)4C: The outdoor air ventilation rate is not required to be larger than the design outdoor air ventilation rate required by Section 120.1(c)3 regardless of CO2 concentration. D.Outdoor air CO2 concentration shall be determined by one of the following: D.A.CO2 concentration shall be assumed to be 400 ppm without any direct measurement; or D.B.CO2 concentration shall be dynamically measured using a CO2 sensor located within 4 ft of the outdoor air intake. E. When the system is operating during hours of expected occupancy, the controls shall maintain system outdoor air ventilation rates no less than the rate listed in Table 120.1-A for DCV, times the conditioned floor area for spaces with CO2 sensors, plus the rate required by Section 120.1(c)3 for other spaces served by the system, or the exhaust air rate whichever is greater. F. CO2 sensors shall be certified by the manufacturer to be accurate within plus or minus 75 ppm at a 600 and 1000 ppm concentration when measured at sea level and 25°C, factory calibrated, and certified by the manufacturer to require calibration no more frequently than once every 5 years. Upon detection of sensor failure, the system shall provide a signal which resets to supply the minimum quantity of outside air to levels required by Section 120.1(c)3 to the zone serviced by the sensor at all times that the zone is occupied. G. The CO2 sensor(s) reading for each zone shall be displayed continuously, and shall be recorded on systems with DDC to the zone level. DEMAND CONTROL VENTILATION NOTES RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 11:27:33 AM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M000 MECHANICAL NOTES D.L.R.C. FAN SCHEDULE MARK EQUIP.CFM SP. (W.G.)RPM HP FLA MOTOR (ELEC) SONES (DB) WT (LBS) MANUFACTURER & MODEL NO.REMARKS EF -1 RESTROOM EXH FAN 110 0.1"-10.6W 0.4 120 / 1 0.9 8.5 BROAN AE50110DCL 1,2 EF -2 RESTROOM EXH FAN 150 0.1"-42.8W 0.1 120 / 1 1.4 13.1 BROAN QTXE150 1,2,3 REMARKS: 1 EQUIVALENT ACCEPTABLE. 2 INSTALL WITH BACK DRAFT DAMPER. 3 ELECTRICALLY INTERLOCKED WITH LIGHT SWITCH WITH MANUAL OVER-RIDE SWITCH. # EQ AIR DEVICE SCHEDULE MARK FACE SIZE TYPE MOUNTING TYPE DIRECTION MANUF.NOTES S-1 24X24 SUPPLY SURFACE/ LAY-IN 4-WAY TITUS (OR EQUIV.)1,2,3,4 S-2 12X12 SUPPLY SURFACE/ LAY-IN 4-WAY TITUS (OR EQUIV.)1,2,3,4 S-3 ROUND SUPPLY DUCT MOUNTED RADIAL TITUS (OR EQUIV.)1,2,3,4 R-1 -RETURN SURFACE/ LAY-IN 1-WAY TITUS (OR EQUIV.)1,2,3 NOTES: 1. PROVIDE NECESSARY MOUNTING HARDWARE AND ACCESSORIES AS REQUIRED. 2. ALL AIR DEVICES SHALL HAVE MANUFACTURER-APPLIED STANDARD WHITE FINISH UNLESS NOTED OTHERWISE. REFER TO ARCHITECTURAL DRAWINGS FOR RCP COORDINATION. 3. AIR DEVICE SHALL BE OF STEEL CONSTRUCTION. 4. AIR DEVICE SHALL BE INSTALLED COMPLETE WITH MANUFACTURER AVAILABLE MOLDED INSULATION BACKING. FIELD-FABRICATED INSULATION BACKING IS NOT ALLOWED UNLESS FIRST APPROVED BY THE OWNER'S CONSTRUCTION MANAGER. EXISTING SPLIT SYSTEM INDOOR FAN COIL SCHEDULE MARK MANUFACTURER MODEL TYPE CFM ELECTRICAL WEIGHT (LBS) DIMENSIONS (HxWxD) (INCHES) V/PH/HZ MCA MOCP FC -1 EXISTING --1,600 ----- FC -2 EXISTING --1,600 ----- FC -3 EXISTING --1,600 ----- NOTES: 1 THERMOSTATS INSTALLED AT 48"AFF. 2 EXTEND CONDENSATE DRAIN DIRECTLY TO A LOCAL CODE APPROVED RECEPTOR. 3 PROVIDE STANDARD THROWAWAY CONSTRUCTION FILTERS OF MERV 13. MECHANICAL CONTRACTOR SHALL FURNISH AND FIELD INSTALL NEW FILTER PRIOR TO BUILDING OCCUPANCY (INCLUDING FOR INTERNAL PRESSURE DROP. # EQ EXISTING SPLIT SYSTEM OUTDOOR HEAT PUMP SCHEDULE MARK MANUFACTURER MODEL NOMINAL TONS COOLING CAPACITY (BTUH)HEATING CAP. (BTUH) ELECTRICAL EER2 / SEER2 HSPF2 WEIGHT (LBS) DIMENSIONS (HxWxD) (INCHES) TH SH V/PH/HZ MCA MOCP HP -1 EXISTING -4 ---------- HP -2 EXISTING -4 ---------- HP -3 EXISTING -4 ---------- NOTES: 1 INSTALL OUTDOOR UNIT WITH DISCONNECT SWITCH AND ALL WEATHERPROOF GFCI. 2 INSTALL PER MANUFACTURER'S MANUAL. # EQ KITCHEN EXHAUST FAN/MAKE-UP AIR SCHEDULE MARK EQUIP.CFM SP. (W.G.)RPM HP FLA MOTOR (ELEC) SONES (DB) WT (LBS) MANUFACTURER & MODEL NO.REMARKS KEF -1 KITCHEN HOOD EXH FAN 2400 3.0 1403 5.0 14.5 208 / 3 31.6 564 CAPTIVEAIRE USBI20DD-RM 1,2,3 MAU -1 KITCHEN MAKE-UP AIR 1920 0.5 927 1.0 3.8 208 / 3 7.8 766 CAPTIVEAIRE A2-20D 1,3 REMARKS: 1 EQUIVALENT ACCEPTABLE. 2 KITCHEN HOOD EXHAUST FAN; HOOD CONTRUCTION: 430SS. 3 INTERLOCK EXHAUST FAN AND MAKE-UP FAN AIR FAN WITH HOOD CONTROL AND EMERGENCY SHUT-OFF. EXHAUST & MAKE-UP AIR SYSTEMS ARE ELECTRICALLY INTERLOCKED WITH ONE ELECTRIC SWITCH. # EQ RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:41:51 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M001 MECHANICAL SCHEDULES D.L.R.C. N.T.S. SCALE:CEILING DIFFUSER DETAIL MAIN TRUNK DUCT ROUND OR RECTANGULAR INSULATED SUPPORT END OF RIGID DUCT FROM STRUCTURE NYLON BAND OVER INSULATION (TYPICAL) HIGH EFFICIENCY TAKEOFF EXTERNALLY INSULATED WITH VOLUME DAMPER AND DAMPER LOCK WITH EXTENSION SEE NOTES PRE-INSULATED FLEXIBLE DUCTWORK. SEE SPECIFICATIONS. LENGTH NOT TO EXCEED 5'-0". PROVIDE SUPPORT PER SMACNA STANDARDS. INSTALL PERMANENTLY SEALED TO PREVENT KINKING, SHARP TURNS AND SAGS. METAL BAND (TYPICAL) CEILING DIFFUSER AS PER MECHANICAL SCHEDULED CEILING LINE NOTE: EXTEND HARD METAL DUCT SO THAT MAXIMUM FLEXIBLE DUCT LENGTH DOES NOT EXCEED 5'-0". PROVIDE RIGID 90° ELBOW WHERE REQUIRED TO KEEP FLEXIBLE DUCT WITHIN 5'-0" LENGTH LIMITATION. 2 PROVIDE 10" FLEX. CONNECTOR COPPER TUBING WITH WROUGHT COPPER FITTINGS A/C. UNIT 6" MIN. SECONDARY OR OVERFLOW DRAIN, SHALL TERMINATE THRU FINISHED CEILING, SOFFIT OR WALL (LOCATED AT VISIBLE LOCATION) BRASS CLEANOUT PLUG (THREADED) PIPING SEE PLANS FOR CONTINUATION OF 3" MIN. UNION FOR TRAP REMOVAL BRASS CLEANOUT PLUG (THREADED) UNION (DI-ELECTRIC WHERE STEEL MEETS COPPER) DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN 1. 2. NOTES: DRAIN PAN ALL CONDENSATE DRAIN LINES INSIDE BUILDING SHALL BE INSULATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE PLUMBING CODE. TRAP DEPTH SHALL BE EQUAL TO THE UNIT TOTAL STATIC PRESSURE PLUS 1-INCH BUT NOT LESS THAN 3-INCHES. N.T.S. SCALE:CONDENSATE DRAIN DETAIL 3 DUCT MOUNTING DETAIL SCALE NTS ROUND DUCT RECTANGULAR DUCT 1 NOTE: REFER TO HOOD MANUFACTURER'S SPECIFICATIONS AND THE ARCHITECTURAL/STRUCTURAL DRAWINGS FOR ADDITIONAL CONSTRUCTION REQUIREMENTS. 1/2" DIA. ALL THREADED ROD @ EACH HOOD SUPPORT (TYP.) HANGING ANGLE INTEGRAL WITH HOOD - SEE HOOD DRAWINGS EXHAUST HOOD - SEE HOOD DRAWINGS NUT & LOCK NUT CONNECTION W/WASHERS (TYP.) 4"x4" WOOD BLOCK HOOD MOUNTING CHANNEL ON HOOD/ HANGING ANGLE INTEGRALWITH HOOD - SEE HOOD DRAWINGS (E) TRUSS MEMBER (TJI) NUT & LOCK NUT CONNECTION W/WASHERS (TYP.) NEW 2x6x48" LG. W/ 12d AT 6" O.C W/ NAILS NOT LOCATED WITHIN 3" OF PIN. SPLICE SHALL BE LOCATED MIDWAY BETWEEN BLKG., TYP. 1/2" DIA. ALL THREADED ROD @ EACH HOOD SUPPORT (TYP.) 5" 1-1/2" 1- 1 / 2 " 5" 2" 3" 2 2"x3"x5" LG. STEEL HANGING ANGLE W/(4) 16d 1 2 1 STEEL HANGING ANGLE FOR WOODBLOCK CONNECTION STEEL HANGING ANGLE FOR HOOD CONNECTION 1/2" DIA. HEAVY DUTY NUT & WASHER-ONE ABOVE AND ONE BELOW HANGING ANGLE 1/2" DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST ANGLE THROUGH ANOTHER HANGING HOOD HANGING DETAIL N.T.S. SCALE: NEW 4x4 @ EA. HANGER W/ "LUS44" EA. END AND PLY.E.N. (E) ROOF SHTG. 5 HOOD EXHAUST (GREASE) DUCT WRAP DETAIL 1 1/ 2 "21" 1 1/ 2 " 1 1/ 2 " 10 1 / 2 " 10 1 / 2 " 1 1/ 2 " NOTES: 1.FIELD APPLIED GREASE DUCT ENCLOSURE SHALL BE INSTALLED PER THE LATEST MANUFACTURER'S INSTALLATION INSTRUCTIONS AND IN COMPLIANCE WITH TERMS OF ITS LISTING. 2.ALL END CUTS OR CUTS IN THE FOIL JACKET OF FIELD APPLIED GREASE DUCT ENCLOSURE SHALL BE SEALED PER THE MANUFACTURER'S RECOMMENDATIONS. 3.ALL INSTALLATIONS SHALL BE COMPLETELY ACCESSIBLE FOR VISUAL INSPECTION. 4.AT TIME OF INSPECTION, THE FIELD APPLIED GREASE DUCT ENCLOSURE INSTALLATION INSTRUCTIONS SHALL BE MADE AVAILABLE AT THE JOB SITE. 5.NON-LISTED GREASE DUCT - DUCTS SHALL BE CONSTRUCTED OF AND SUPPORTED BY CARBON STEEL NOT LESS THAN 0.060 OF AN INCH (NO. 16 MSG) IN THICKNESS OR STAINLESS STEEL NOT LESS THAN 0.048 OF AN INCH (NO. 18 MSG) IN THICKNESS. 6.WELDED DUCT CONNECTION SHALL BE TELESCOPING JOINT, BELL TYPE JOINT, FLANGE WITH EDGE WELD, AND FLANGE WITH FILLED WELD. 7.BUTT WELD CONNECTIONS SHALL NOT BE PERMITTED. N.T.S. SCALE: HIGH PERFORMANCE 1/2" STEEL BANDING FILAMENT TAPE 3" LONGITUDINAL OVERLAP 3" PERIMETER OVERLAP 3M FIRE BARRIER DUCT WRAP 615+ 3" THICK 0" CLEARANCE TO COMBUSTIBLES GREASE DUCT SYSTEM. INSTALL PER MANUFACTURER'S LISTING. 1/2" DIAMETER HANGER ROD 1 1/2"x1 1/2"x1/8" ANGLE HOOD EXHAUST DUCT ACCESS HOLE ACCESS FRAME WELDED TO DUCT 1/4" DIA. ALL THREAD ROD 16 GA. ACCESS COVER INSULATION PINS WELDED TO ACCESS COVER 3M FIRE BARRIER DUCT WRAP 15A SPEED CLIPS SPOOL PIECES FOR THREADED RODS. 1/4" DIA WING NUTS ALUMINUM TAPE AT ALL EXPOSED EDGES 3M INFORMATION PERFORMANCE 3M BARRIER DUCT WRAP 615+ HAS BEEN TESTED IN ACCORDANCE WITH THE FOLLOWING: ASTM E 2336 ASTM E 119 ASTM E 814 ASTM E 84 ASTM E 136 ASTM C 518 UL 1479 ICC-ES AC101 ISO 6944 - 85 CODE ACCEPTANCE PER ASTM E-2336 NFPA 96 INTERNATIONAL MECHANICAL CODE UNIFORM MECHANICAL CODE SEALANTS 3M FIRE BARRIER WATER TIGHT 1000 NS 3M FIRE BARRIER WATER TIGHT 1003 SL 3M FIRE BARRIER WATER TIGHT 2000+ 6 N.T.S. SCALE:EXHAUST FAN DETAILS DISCHARGE @ +40" AFR, MIN. FACTORY ACCESS DOOR IN SCROLL MOTOR & DRIVE WEATHER COVER SCROLL DRAIN GREASE RESERVOIR WELD TO FAN OUTLET DUCT TO RUN HORIZONTALLY, MIN.1/4" PER LINER FOOT. SEE DUCT ELEVATION VIEW M003 DETAIL #2 NOTE: EXHAUST OUTLET TERMINATING ABOVE THE ROOF SURFACE SHALL TERMINATE NOT LESS THAN 5 FEET HORIZONTALLY FROM COMBUSTIBLE STRUCTURE. BASE OF FAN SHALL BE 40 INCHES ABOVE ROOF SURFACE. 4 GYPSUM BD. CEILING TILES COOKING SURFACE 6" MIN. EXH. DUCT. WITH 2 LAYER 3M FIRE BARRIER DUCT WRAP. SEE DUCT WRAP FROM TOP OF THE HOOD TO 18" ABOVE ROOF SURFACE. DETAIL SHOWN ON THIS SHEET. CONTRACTOR SHALL SLOPE THE EXHAUST AIR DUCT NO LESS THAN 1/4" PER LINER FOOT. GREASE DUCT SHALL BE CONSTRUCTED WITH 16 GAUGE GALVANIZED SHEET METAL WITH WELDED SEAMS. EXTEND LIMITED COMBUSTIBLE OR NONCOMBUSTIBLE CEILING MATERIAL 18" BEYOND OUTER EDGE OF THE DUCT. CEILING SPACE. TYPE I HOOD. SEE KITCHEN DWG.108" 18"MIN.TOP OF HOOD CEILING HT. METAL SHIELD OR COLLAR (TO SEAL DUCT AT POINT OF PENETRATION) GREASE DUCT SYSTEM MUST BE ACCESSIBLE FROM DUCT ENTRY TO DISCHARGE; PROVIDE OPENINGS IN COMPLIANCE PER MECHANICAL CODE EXHAUST RISER HANGING ANGLE L55 SERIES E26 CANOPY LIGHT FIXTURE 6" 2 3/4" 16" SUPPLY RISER W/VOLUME DAMPER 18" 80" AFF REFERENCE 24" NOM. GREASE DRAIN WITH REMOVABLE CUP 48" MAX 6" MIN. METAL STUD WALLS WITH 5/8"GYP. BOARD WALL CONSTRUCTION AND 1" MINERAL WOOL BATT OR CERAMIC BLANKET. 22 GA. S/S BACKING COVERS ENTIRE BACK AREA OF HOOD. MIN.18" FROM GYP. BD. CEILING TO TOP OF HOOD. THE HOOD SHALL HAVE A CLEARANCE OF AT LEAST 3" FROM METAL STUD WALLS WITH GYP. BD. (AS SHOWN). MATERIALS WITHIN 3" OF THE HOOD MUST BE NON-COMBUSTIBLE. PROVIDE DUCT OPENINGS IN EVERY 12' INTERVAL AND EVERY TURN. N.T.S. SCALE:KITCHEN HOOD SECTION DETAIL 20" CAPTRATE SOLO FILTER NOTLESS THAN 45 DEG. FROMHORIZONTAL GENERAL NOTES: 1.LISTED GREASE HOOD ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE WITH THE TERMS OF THEIR LISTING AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.THE HOOD EXHAUST FAN SHALL CONTINUE TO OPERATE AFTER THE EXTINGUISHING SYSTEM IS ACTIVATED UNLESS SHUTDOWN IS REQUIRED AS A COMPONENT OF THE EXTINGUISHING SYSTEM. 7 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:41:53 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M002 MECHANICAL DETAILS D.L.R.C. MECHANICAL PLAN #KEYED PLAN NOTES: 1.P.O.C. TO EXISTING EXHAUST VENT. FIELD VERIFY ALL EXISTING CONDITIONS SIZE AND LOCATIONS PRIOR TO START OF THIS WORK. 2.INSTALL PROGRAMMABLE THERMOSTAT 48"AFF. 3.TYPE 1 HOOD; KITCHEN HOOD MUST OVERHANG MIN. 6" FROM EDGES OF KITCHEN EQUIPMENT BELOW. MAINTAIN GREASE DUCT SLOPE OF MIN 2%. 4.P.O.C. TO EXISTING 8'' x 26'' GREASE EXHAUST DUCT. FIELD VERIFY ALL EXISTING CONDITIONS SIZE AND LOCATIONS PRIOR TO START OF THIS WORK. EXISTING VERTICAL DUCT SHAFT AND VERTICAL GREASE DUCT PROVIDED BY THE LANDLORD TO REMAIN. EXISTING GREASE DUCT OPENING AT EACH FLOOR TO REMAIN. 5.INSTALL AIR CURTAIN AT DELIVERY DOOR. THE AIR CURTAIN SHALL PROVIDE A DOWNWARD-OUTWARD FLOW NOT LESS THAN 8" WIDE NOZZLE AND AN AIRFLOW NOT LESS THAN 1600 FPM ACROSS THE ENTIRE OPENING AT A POINT MEASURED 3' ABOVE THE FLOOR. THE AIR CURTAIN MUST BE ON AUTOMATICALLY WHEN THE DOOR IS OPENED. 6.CONDENSATION PIPE DISCHARGE BY DIRECT CONNECTION TO LAV TAILPIECE. GENERAL NOTES: 1.IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION, CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATION REFLECTING ACTUAL CONDITIONS. 2.ENVIRONMENTAL EXHAUST TERMINATION TO BE MINIMUM 3 FEET FROM A PROPERTY LINE, 10 FEET FROM A FORCED AIR INLET, AND 3 FEET FROM OPENINGS INTO THE BUILDING. UP DN UP DNUP KEY PLAN SCOPE OF WORK EXISTING VERTICAL GREASE DUCT SHAFT UP 4 C-05 108 OUTDOOR DINING PATIO MEN'S RRWOMEN'S RR STORAGE DINNING AREA KITCHEN AREA HALLWAY SERVICE AREA 4 EXISTING VERTICAL GREASE DUCT SHAFT 400 S - 3 (TYP. 3) (E)3 FC (E)1 FC 1050 R - 1 D U (A B O V E C E I L I N G ) 126''X10'' OSA LOUVERED GRILLE 1920 CFM (E)2 FC 1300 R - 2 650 R - 1 (TYP. 2) 475 S - 3 (TYP. 2) 500 S - 3 75 S - 2 75 S - 2 200 S - 1 200 S - 1 450 S - 1 (TYP. 2)300 S - 1 250 R - 1 400 S - 1 (E)14"X10'' (E)24''X10'' OSA LOUVERED GRILLE 250 CFM FOR EACH FAN COIL OSA OSA OSA OSAOSA OS A OS A OS A OS A OS A OS A OS A OS A OS A OS A OS A OS A OS A OS A OS A OS A OS A OS A 2 EF 1 EF1 2T1 CO2 2T2 2T3 14"Ø 12"Ø 8"Ø 6"Ø 18"Ø 16"Ø 12"Ø 16"Ø (E)8''X8'' (E)14"X10'' 8"Ø 16"Ø 10"Ø 14"Ø 18"Ø 16"Ø 16"Ø 16"Ø 18"Ø 10"Ø 14"Ø 6"Ø8"Ø14"Ø 8''X8'' (E)8''X8'' 10"Ø 5 20"X10'' OSA 12"Ø 16"Ø 640 CFM (TYP. 3) 3 CD CD CD 1-1/2"CD 6 18"Ø AI R F L O W . AI R F L O W . (A B O V E C E I L I N G ) 1 MAU RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:41:55 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M100 1/4" = 1'-0" MECHANICAL PLAN D.L.R.C. MECHANICAL PLAN - ROOF PLAN GENERAL NOTES: 1.IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION, CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATION REFLECTING ACTUAL CONDITIONS. FI R E W A L L DN 1-007 BRACING PER STRUCTURAL ACCESS LADDER 1 KEF 1 #KEYED PLAN NOTES: 1.EXISTING 8'' x 26'' GREASE DUCT. 14"Ø RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:41:57 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M101 1/4" = 1'-0" MECHANICAL PLAN - ROOF PLAN D.L.R.C. Southern California Office REGION 86 PHONE: (714) 957 - 1500 EMAIL: reg86@captiveaire.com FOR QUESTIONS, CALL THE 1 5424 ND-2-PSP-F CAPTIVEAIRE 12' 0"600 DEG I HEAVY 200 2400 10"23"4"2400 1503 -0.681"1920 430 SS WHERE EXPOSED ALONE ALONE HOOD NO TAG MODEL MANUFACTURER LENGTH MAX COOKING TEMP TYPE APPLIANCE DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM RISER(S) WIDTH LENG HEIGHT DIA CFM VEL SP TOTAL SUPPLY CFM HOOD CONSTRUCTION HOOD CONFIG END TO END ROW 1 CAPTRATE SOLO FILTER 9 20"16"85% SEE FILTER SPEC 3 RECESSED ROUND NO YES 787 LBS HOOD NO TAG FILTER(S) TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS LIGHT(S) QTY TYPE WIRE GUARD UTILITY CABINET(S) LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WEIGHT 1 FIELD WRAPPER 18.00" HIGH FRONT, LEFT, RIGHT. BACKSPLASH 80.00" HIGH X 144.00" LONG 430 SS VERTICAL. RISER SENSOR INSTALL 6IN PLEN. RIGHT VERTICAL END PANEL 27" TOP WIDTH, 21" BOTTOM WIDTH, 80" HIGH INSULATED 430 SS. LEFT VERTICAL END PANEL 27" TOP WIDTH, 21" BOTTOM WIDTH, 80" HIGH INSULATED 430 SS. HOOD NO TAG OPTION 1 Front 144"14"6" MUA MUA MUA 12" 12" 12" 28" 28" 28" 640 640 640 0.157" 0.157" 0.157" HOOD NO TAG POS LENGTH WIDTH HEIGHT TYPE RISER(S) WIDTH LENG DIA CFM SP 1 WALL MNT 12"x36"x24"TANK FS 4.0/4.0 300.00 LBS UTILITY CABINET(S) HOOD NO LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY WEIGHT 1500500 FLOW RATE (CFM) 1000 0.00 0 0.50 PR E S S U R E D R O P ( i n . H 2 0 ) PRESSURE DROP VS. FLOW RATE RRSPECIFICATION: CAPTRATE GREASE-STOP SOLO FILTER A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, THE CAPTRATE GREASE-STOP SOLO FILTER IS A SINGLE-STAGE FILTER FEATURING LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND COMPONENTS WHEN ASSEMBLED. 2-INCH DEEP HOOD CHANNEL(S). TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO FR A C T I O N A L E F F I C I E N C Y ( % ) 0 0.1 20 40 1.0 PARTICLE DIAMETER (UM) 10.0 EFFICIENCY VS. PARTICLE DIAMETER 60 80 100 THE CAPTRATE GREASE-STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. TE A NSF ACCORDANCE No. 96 NFPA WITH BUILT IN SLI DTE RO CH B N RAN I,OR M . YR OR LAIGNTSB AT CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. NFPA #96. NSF STANDARD #2. UL STANDARD #1046. INT. MECH. CODE (IMC). ULC-S649. 1.00 1.50 2.00 2.50 3.00 3.50 MANUFACTURER APPROVED FOR USE IN SOLID FUEL APPLICATIONS AS A SPARK ARRESTER. PATENT NUMBERS AC-PSP WALL (CANADA) - CA PATENT 2820509. AC-PSP (UNITED STATES) - US PATENT 7963830 B2. AC-PSP ISLAND (CANADA) - CA PATENT 2520330. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. FULL LENGTH HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). FULL LENGTH HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. SUPPLY PLENUM HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR SUPPLY PLENUM). SUPPLY PLENUM HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR PSP HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) WALL-MOUNT UTILITY CABINET ASSEMBLY INSTRUCTIONS CABINET TO BE HUNG BY OTHERS. SEE UTILITY CABINET SCHEDULE FOR CABINET SIZE. HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH UTILITY CABINET HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). UTILITY CABINET HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. (HARDWARE BY INSTALLER) HOODS #SURFACE *CLEARANCE 1 TOP 18" FRONT 0" BACK 18" LEFT 18" RIGHT 18" - *0" CLEARANCE TO COMBUSTIBLES CONFORMS TO UL710 STANDARD. HEIGHT - BACKSPLASH IS NOT INSULATED AND IS UNSUITABLE FOR INSTALL AGAINST COMBUSTIBLE WALLS BACKSPLASH PANELS SLIDE INTO DIVIDER BAR NON-COMBUSTIBLE WALL LENGTH SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 8221654 MASTER DRAWING AR Ar t e R e s t a u r a n t - S a n t a A n a , C A R e v 1 10 9 E a s t 4 t h S t r e e t , So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m Sa n t a A n a , C A , 9 2 7 0 1 FANSLIGHTS CAN MOUNT IN STANDARD DOUBLE GANG JUNCTION BOX CAT-5 CONNECTION ON REVERSE CONNECTED TO HOOD CONTROL PANEL CONTROL BUTTON TYPICAL 4 ALARM INDICATING LCD SCREEN FUNCTION VARY DEPENDING ON PACKAGE TYPE & OPTIONS ROOM TEMPERATURE Provides room override based on temperature differential between the room and duct. Installed by electrician on a wall, 5'-6' off the finished floor, in the space but not directly under the hood or close to an appliance (including the electrical control box) so the reading is accurate for space. SENSOR DIMENSIONS: 3.25"H X 2"W RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:41:59 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M200 HOOD INFORMATION D.L.R.C. 12' 0"NOM./12' 0.00"OD. 54" 14" 24" 7" 12" 28" 48" 7" 12" 28" 48" 7" 12" 28" 3" 72"72" 9" 10" 23" U.L. LISTED RECESSED ROUND LED FIXTURE AND LED LIGHT. NOTE: ADDITIONAL HANGING ANGLES PROVIDED FOR HOODS 12' AND LONGER. 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. §EXHAUST RISER. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. ATTACHING PLATES. SUPPLY RISER WITH VOLUME DAMPER. 6" 2 3/4" 14" 18" BACKSPLASH 80.00" HIGH X 144.00" LONG. FIELD WRAPPER 18.00" HIGH (SEE HOOD OPTIONS TABLE). 20" 4" 4 1/2" 21" 27" 80" LEFT AND RIGHT VERTICAL END PANELS WITH ADJUSTABLE LEGS. GAS CHASE CUTOUT (FOR GAS AND POWER LINES). EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 8221654 MASTER DRAWING AR Ar t e R e s t a u r a n t - S a n t a A n a , C A R e v 1 10 9 E a s t 4 t h S t r e e t , So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m Sa n t a A n a , C A , 9 2 7 0 1 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:42:01 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M201 HOOD INFORMATION D.L.R.C. 1 TANK FS 4.0/4.0 40 37 WALL UTILITY CABINET LEFT N/A FIRE SYSTEM NO TAG TYPE SIZE MAX FP DESIGN FP INSTALLATION SYSTEM LOCATION ON HOOD 1 SC ELECTRICAL 2.500 CAPTIVEAIRE SYSTEMS FIRE SYSTEM NO TAG TYPE SIZE SUPPLIED BY 1 0 - 0 - TANK FIRE SUPPRESSION POST-DISCHARGE PROCEDURE UTILITY CABINET LABEL SHEET. 0 - 0 - TANK FIRE SUPPRESSION MAINTENANCE GUIDE UTILITY CABINET LABEL SHEET. 0 - 0 - 12-F28021-32144-OT-360 DUCT FIRE THERMOSTAT WITH 12 FOOT WIRE LEADS. NO, CLOSE ON TEMP RISE AT 360°F. (A0034310). 0 - 0 - 32-00002 QUIK SEAL - 1/2" (UL). 0 - 0 - 361091 3/8" BRASS PLUG. 0 - 0 - 4429K153 1/2" MALE NPT TO 1/2" FEMALE NPT ELBOW, BRASS. 0 - 0 - 4429K422 1/2" X 1/4" BRASS REDUCING BUSHING. 0 - 0 - 79425 3/8" NPT FEMALE TO 1/2" MALE PROPRESS ADAPTER. 0 - 0 - 79525 1/2" 90 PRO-PRESS ELBOW WITH 1/2” NPT FEMALE CONNECTION, VIEGA. 0 - 0 - 79580 1/2" X 1/2" PRO-PRESS TEE X 1/2” NPT FEMALE CONNECTION, VIEGA. 0 - 0 - 87-120042-001 SECONDARY ACTUATOR VALVE (SVA) - SINGLE ACTUATOR, REQUIRES PRIMARY RELEASE ACTUATOR, TANK FIRE SUPPRESSION. 0 - 0 - 87-120045-001 HOSE, SECONDARY ACTUATOR HOSE, 7.5" BRAIDED STAINLESS STEEL, TANK FIRE SUPPRESSION. 0 - 0 - 87-300001-001 TANK - PRESSURIZED TANK USED FOR TANK FIRE SUPPRESSION. 0 - 0 - 87-300030-001 PRIMARY ACTUATOR KIT (PAK) - ACTUATOR AND RELEASE SOLENOID ASSEMBLY, ONE NEEDED PER FIRE SYSTEM, SUPERVISED, TANK FIRE SUPPRESSION. 0 - 0 - 87-300033-001 DIN CONNECTOR, CANFIELD PART #5J560-201-EU0A, TANK FIRE SUPPRESSION, SUBMINATURE SOLENOID CONNECTION (CED VENDOR 30377). 0 - 0 - 87-300152-001 HARDWARE, SVA BOLTS, TANK FIRE SUPPRESSION. 0 - 0 - 9055455PC PRO PRESS 1/2 PRESS X PRESS 90 ELBOW LD. 0 - 0 - 9097200PC PRO PRESS PC611 1/2 PRESS TEE LD. 0 - 0 - 98694A115 HARDWARE, DATANKLOCK LOCKING BRACKET SQUARE NUTS 5/16" ZINC, TANK FIRE SUPPRESSION. 0 - 0 - A0034332 JUNCTION BOX FOR MANUAL PULL STATION. 1.5" DEEP BACK BOX, RED COLOR. 0 - 0 - A31484 1/4" NPT SCHRADER VALVE AND CAP, JB INDUSTRIES. 1/4" FLARE X 1/4" MPT HALF UNION. USED ON TANK SERVICE PORT. 0 - 0 - BI145 3/8" BLACK IRON 90 ELL. 0 - 0 - DATANKLOCK DISCHARGE ADAPTER TANK LOCKING PLATE FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY CABINETS, TANK FIRE SUPPRESSION. 0 - 0 - SLPCON-30FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO CONNECT THE SUPERVISED LOOP BETWEEN HOODS WITH UPTO 29' GAP. KIT CONTAINS 32 FEET OF BLACK MG WIRE, 32 FEET OF TAN MG WIRE, 30 FEET OF FLEXIBLE CONDUIT, AND TWO 7/8" CONNECTORS. 0 - 0 - TANK STRAP TANK STRAP - USED FOR TANK FIRE SUPPRESSION. 0 - 0 - TFS-UCTANKBRACKET TANK BRACKET FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY CABINETS, TANK FIRE SUPPRESSION. 0 - 0 - WK-283952-000 DISCHARGE ADAPTER, TANK FIRE SUPPRESSION. 16 - 16 - 79210 1/2" X 3/8" NPT MALE ADAPTER, VIEGA. 16 - 16 - OL-F NOZZLE - TANK PROTECTION APPLIANCE COVERAGE NOZZLE (INCLUDES METAL BLOW OFF CAP, LANYARD, USED WITH CHROME-PLATED PIPE). 26 - 26 - QSA-3/8 QUIK SEAL - 3/8" (UL). 34 - 34 - A0034331 RED COLOR - 24VDC SINGLE ACTION MANUAL ACTUATION DEVICE (PUSH/PULL STATION) WITH PROTECTIVE COVER, ONE (1) NORMALLY OPEN CONTACT. 1 1 1 1 3 2 1 3 1 2 1 1 2 1 1 8 5 8 4 1 1 3 2 2 6 2 2 8 8 8 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 FIRE SYSTEM NO TAG KEY NUMBER - PART DESCRIPTION QTY BY FACTORY QTY BY DIST FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. 9" 10" 23" HOOD FRONT HOOD BACK HOOD # 1 JOB # 8221654 FS # 1 MODEL: ND-2-PSP-F SIZE: 54"x24" LENGTH: 12' 0" TA N K O V E R L A P P I N G P R O T E C T I O N - 3 0 HI G H P R O X I M I T Y 13 2 . 0 0 " L X 3 0 . 0 0 " D DUCT S 360 OL-F OL-F OL-F 25.00" 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F NOZZLE HEIGHT 35-50" FROM COOKING SURFACE. (45.25") 18.00"27.00"27.00"27.00"27.00"18.00" SLPCON-30FT KIT SLPCON-30FT KIT 36.00" 12.00" 36.00" 24.00" WALL UC BACK WALL UC FRONTHood#1 HANGING ANGLES IN EACH CORNER. 1 631 7 2 5 - SYSTEM REQUIRES A MINIMUM OF 7 FT OF EQUIVALENT PIPE LENGTH BETWEEN TANK AND NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES. EACH 90 DEGREE ELBOW ADDS 1.3 FT OF EQUIVALENT LENGTH. SEE MANUAL FOR DETAILS TO HOOD# 1 WALL-UC ALTERNATE FIELD-CONNECTION POINTPL E N U M PL E N U M NOTES - FIELD PIPE DROPS AS SHOWN PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS. - FIELD INSTALLED DROP: FACTORY WILL PROVIDE QTY 2 60IN LONG PIECES OF CHROME PLATED PIPING SHIPPED LOOSE TO BE FIELD-INSTALLED. - SHIP LOOSE DROP: FACTORY WILL PROVIDE THE EXACT CHROME PIPE LENGTH NEEDED SHIPPED LOOSE TO BE FIELD-INSTALLED. - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - OVERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN OBSTRUCTION. - IF APPLICABLE, EXTENDED PRE-PIPED DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS PRE-ENGINEERED FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS. - OL-F NOZZLE PART NUMBER REPLACES 3070-3/8H-10-SS JOB #: 8221654. JOB NAME: ARTE RESTAURANT - SANTA ANA, CA REV1. SYSTEM SIZE: TANK-SP-2-WC DESIGN FP: 37. MAXIMUM FP: 40. HOOD # 1 12' 0.00" LONG x 54" WIDE x 24" HIGH. RISER # 1 SIZE: 10" x 23". HOOD # 1 METAL BLOW-OFF CAPS INCLUDED. - HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITIONAL DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK CONTAINS ANY HORIZONTAL RUNS OVER 25 FT IN LENGTH. - MEDIUM TO LIGHT-DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE ANY ADDITIONAL DOWNSTREAM DETECTION. AGENT DISTRIBUTION PIPING LIMITATIONS PIPE SECTION MAX PIPE LENGTH (FT) MAX SUPPLY LINE TO FIRST OVERLAPPING NOZZLE 42 OVERLAPPING NOZZLE APPLIANCE BRANCH 10 DEDICATED NOZZLE APPLIANCE BRANCH 10 PRESSURE SUPERVISION SWITCH. PRIMARY ACTUATOR RELEASE. 4 GALLON TANK. 7 6 5 4 2 1 PRIMARY HOSE ASSEMBLY. SECONDARY ACTUATOR RELEASE.3 SECONDARY HOSE ASSEMBLY. REMOTE MANUAL ACTUATION DEVICE. 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. §EXHAUST RISER. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. ATTACHING PLATES. SUPPLY RISER WITH VOLUME DAMPER. 6" 2 3/4" 14" 18" BACKSPLASH 80.00" HIGH X 144.00" LONG. FIELD WRAPPER 18.00" HIGH (SEE HOOD OPTIONS TABLE). 20" 4" 4 1/2" 21" 27" 80" LEFT AND RIGHT VERTICAL END PANELS WITH ADJUSTABLE LEGS. GAS CHASE CUTOUT (FOR GAS AND POWER LINES). EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 21 1/2" TANK FIRE SUPPRESSION PUSH 4-5/8" 3-3/16" 5-3/8" 7-3/8" INCLUDES: FIELD INSTALLATION AND HOOKUP DURING NORMAL BUSINESS HOURS BY CERTIFIED INSTALLERS ONLY IN THE LOCATION NOTED ABOVE, TWO SITE VISITS ONLY (ONE VISIT TO SET PULL STATION & SYSTEM HOOKUP AND ONE VISIT FOR ONE TEST; ADDITIONAL VISITS WILL RESULT IN ADDITIONAL CHARGES), ONE MECHANICAL OR ELECTRICAL GAS VALVE PER SYSTEM AT A MAXIMUM SIZE OF 2", PERMIT, AND SYSTEM TEST. EXCLUDES: UNION LABOR & PREVAILING WAGE (LABOR & WAGES WILL BE ADDED IF APPLICABLE), GAS VALVE INSTALLATION, ELECTRICAL HOOKUP AND CONNECTIONS, HANGING OF FIRE CABINET, SHUNT TRIP, HANDHELD EXTINGUISHER(S), ON-SITE RE-PIPING DUE TO EQUIPMENT LAYOUT CHANGES. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 8221654 MASTER DRAWING AR Ar t e R e s t a u r a n t - S a n t a A n a , C A R e v 1 10 9 E a s t 4 t h S t r e e t , So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m Sa n t a A n a , C A , 9 2 7 0 1 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:42:03 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M202 HOOD INFORMATION D.L.R.C. 1 EF 1 USBI20DD-RM CAPTIVEAIRE 2400 3.000 1403 TEFC,PREMIUM 5.000 2.0620 3 208 14.5 1045 FPM 564 31.6 FAN UNIT NO TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA DISCHARGE VELOCITY WEIGHT (LBS)SONES 2 MAU 1 A2-20D 20MF-2-MOD A2 1500 1920 0.500 927 ODP,PREMIUM 1.000 0.4230 3 208 3.8 4.8A 15A 2.72 90.0°F 69.0°F 71.0°F 69.0°F 766 7.8 FAN UNIT NO TAG QTY FAN UNIT MODEL #BLOWER HOUSING MIN CFM DESIGN CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA MCA MOCP EVAP FLOW RATE (Gal/Hr) EVAP COOLER ENTERING DB TEMP EVAP COOLER ENTERING WB TEMP EVAP COOLER LEAVING DB TEMP EVAP COOLER LEAVING WB TEMP WEIGHT (LBS)SONES 1 2 EF MAU YES YES FAN UNIT NO TAG EXHAUST GREASE CUP GRAVITY DAMPER WALL MOUNT SUPPLY SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 2 # 1 # 2 # 2 # 2 EF 76 LBS 55 LBS CURB CURB RAIL RAIL 31.000"W X 45.000"L X 20.000"H VENTED. 31.000"W X 31.000"L X 20.000"H. 4.000"W X 4.000"L X 36.000"H. 4.000"W X 4.000"L X 36.000"H. NO ON FAN TAG WEIGHT ITEM SIZE FAN UNIT NO TAG QTY DESCRIPTION 1 EF 1 BI20 - INLET SERVICE DUCT CONNECTION. USED TO CONNECT TO STANDARD 20" GREASE DUCT OR FIELD WELDED DUCT. INCLUDES (2) 7" RISERS BOLTED TO STANDARD INLET RISER 1 UTILITY SET GREASE CUP 1 BI20 - 24" DISCHARGE EXTENSION 1 BI - DISCHARGE ORIENTATION VERTICAL UPPER LEFT - CW INLET SIDE 1 BI20 - INLET CONNECTION STANDARD 20" FLANGED GREASE DUCT 1 CURB MOUNTED SLED FOR USBI 20. USED TO MOUNT ON 45" L X 31" W CURB 1 UTILITY SET - FAN SLED RESTRAINED SPRING VIBRATION ISOLATORS - BI11 THRU BI20 / EQUIVALENT SIZED UTILITY SET - INDOOR/OUTDOOR USE (SET OF 6) 1 2 YEAR PARTS WARRANTY 2 MAU 1 EVAPORATIVE COOLER WIRING HARNESS 1 INSULATION OPTION FOR VBANK FILTER SECTION 1 A2 INDOOR HANGING OPTION - INCLUDES 2 HSA125 HANGING SPRING ISOLATORS PER UNI-STRUT 1 SEPARATE 120V WIRING PACKAGE (REQUIRED AND USED ONLY FOR DCV OR PREWIRE WITH VFD) - THREE PHASE ONLY 1 2 YEAR PARTS WARRANTY 47 7/8" 21 13/16"15 1/4" 31 3/8" 28 11/16" 25 11/16" 42 7/16" 22" 38 3/16" SHAFT 38 1/2" DIA. 32 9/16" 1 1/4" 20" *INLET FIRESTAT LOCATION TO BE INSTALLED BY ELECTRICIAN *OUTLET 6" 2IN DRAIN - CURB MOUNTED FANS WITH VIBRATION ISOLATOR - FULL PERIMETER CURB - LIFTING HOOK POCKETS ON ALL SIDES - UL705 - UL762 & ULC-S645 (RESTAURANT MODEL) - HIGH HEAT OPERATION DIRECT DRIVE 350°F (176°C) - HEAT SLINGER - GREASE CLASSIFICATION TESTING - 2" DRAIN - MOTOR WEATHER COVER - FULLY SEALED SCROLL HOUSING - SCROLL ACCESS DOOR 36 11/16"50 11/16" 11 9/16" 45" 20" 31" SUPPORT CURB OPTION - FLANGE 1 1/4" - 11 THRU 20 (6) ISOLATORS = USBI18 THRU 36 5 5/8" FAN #1 USBI20DD-RM - EXHAUST FAN (EF) OPTIONS - BI20 - INLET SERVICE DUCT CONNECTION. USED TO CONNECT TO STANDARD 20" GREASE DUCT OR FIELD WELDED DUCT. INCLUDES (2) 7" RISERS BOLTED TO STANDARD INLET RISER. - UTILITY SET GREASE CUP. - BI20 - 24" DISCHARGE EXTENSION. - BI - DISCHARGE ORIENTATION VERTICAL UPPER LEFT - CW INLET SIDE. - BI20 - INLET CONNECTION STANDARD 20" FLANGED GREASE DUCT. - CURB MOUNTED SLED FOR USBI 20. USED TO MOUNT ON 45" L X 31" W CURB. - UTILITY SET - FAN SLED RESTRAINED SPRING VIBRATION ISOLATORS - BI11 THRU BI20 / EQUIVALENT SIZED UTILITY SET - INDOOR/OUTDOOR USE (SET OF 6). - 2 YEAR PARTS WARRANTY. CORNER WEIGHTS ARE CALCULATED BASED ON VERTICAL DISCHARGE. SUPPORT DUCT PROPERLY BEFORE FAN TO ENSURE CORNER WEIGHTS ARE NOT AFFECTED. INLET NORMAL TEMPERATURE TEST DIRECT DRIVE DETERIORATING EFFECTS TO THE FAN WHICH THERMAL EQUILIBRIUM, AND WITHOUT ANY UNTIL ALL FAN PARTS HAVE REACHED WHILE EXHAUSTING AIR AT 350°F (176°C) EXHAUST FAN MUST OPERATE CONTINUOUSLY WOULD CAUSE UNSAFE OPERATION. 24" EXTENSION. OPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Label Description Location MT-01 Fan Motor [3] SW-01 Main disconnect switch [3] Component Identification 23 Installed Options RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES FIELD WIRING DENOTES INTERNAL WIRING NOTES SW-01 BK BK MT-01 GR BK GR BK BK BK 5 6 3 4 1 2 GR EXHAUST 5.0HP-208V-3P-14.5FLA VFD: ESV402N02TXB571 MOTOR INFO ELECTRICAL INFORMATION MOTOR/CTRL MCA: 18.2A MOTOR/CTRL MOP: 30A DRAWING NUMBER JOB MODELSHIP DATEEXH8221654-1 8221654 - Arte Restaurant - Santa Ana, ... 9/5/2025 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 8221654 MASTER DRAWING AR Ar t e R e s t a u r a n t - S a n t a A n a , C A R e v 1 10 9 E a s t 4 t h S t r e e t , So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m Sa n t a A n a , C A , 9 2 7 0 1 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:42:04 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M203 HOOD INFORMATION D.L.R.C. FLEX CONDUIT FOR FIELD WIRING. LIFTING LUG. 3 3/4" 22" 10 15/16" 5 5/8"24 3/4" UNI-STRUT BASE FOR HANGING 60" AIRFLOW. BLOWER/MOTOR ACCESS DOOR 24" SERVICE CLEARANCE REQ. SERVICE DISCONNECT SWITCH. AIRFLOW. 20" 19" Ø1 1/2" WATER DRAIN. AIRFLOW. Ø1/2" NPT WATER INLET WATER FILTER REQUIRED PROVIDED BY PLUMBER. FILTER/CONTROL ACCESS DOOR. LPD CELDEK AIRFLOW. V-BANK FILTER MODULE. AIRFLOW. FILTER ACCESS DOOR. 29 1/4" 33 7/8" 7 1/2" 4 5/8" UNI-STRUT BASE FOR HANGING 60" Ø1-1/2" DRAIN. WATER 4 1/2"20" 37 3/8" 16 1/4" 31" 20" EQUIPMENT CURB. 40 1/8" 36 3/4" 31" 38 1/8" 43 3/8" 40 3/4" ADJUSTABLE LEG. 38 1/8" ADJUSTABLE LEG. 116 3/8" 1" 39 1/8" 77 1/4" 115 3/8" MINIMUM STRAIGHT DUCT PER AMCA* MIN. 26" FAN #2 A2-20D - SUPPLY FAN (MAU) 1. UNTEMPERED SUPPLY UNIT WITH 20" MIXED FLOW DIRECT DRIVE FAN IN SIZE #2 HOUSING. 2. EVAP COOLER (LPD CELDEK) & V-BANK WITH 2" TA-13 FILTERS-INDOOR. 3. SIDE DISCHARGE - AIR FLOW RIGHT -> LEFT. 4. 120V WIRING CONNECTION TO ENERGIZE EVAPORATIVE COOLERS FROM UNTEMPERED SUPPLY FANS. 5. "INSULATION" FOR V-BANK INTAKE OPTION. 6. INDOOR HANGING CRADLE FOR THE SIZE 2 UNTEMPERED UNIT. 2 HSA125 HANGING ISOLATORS PER UNI-STRUT INCLUDED. 7. SEPARATE 120VAC WIRING PACKAGE FOR MAKE-UP AIR UNITS. OPTION MUST BE SELECTED WHEN MOUNTING VFD IN PREWIRE PANEL OR WITH DCV PACKAGE. PROVIDES SEPARATE 120VAC INPUT TO SUPPLY FAN. THIS 120V SIGNAL MUST BE RUN BY ELECTRICIAN FROM DCV TO MUA SWITCH. 8. HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER/EVAP SECTION). 9. 2 YEAR PARTS WARRANTY. *NOTE: SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. SUGGESTED SUPPLY STRAIGHT DUCT SIZE IS 26" x 26". L ETSDI R 2" 2" 3" FLANGE. 20 GAUGE CONSTRUCTION. STEEL 20" 31" 31" CURB. SW-01 BK BK MT-01 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 GR BK GR Label Description Location MT-01 Supply motor [2] SW-01 Main disconnect switch [2] Component Identification 23 BK BK BK Installed Options Cooling Interlock BL WH N 11 DENOTES INTERNAL WIRING DENOTES FIELD WIRING NOTES 7 8RD(DCV SF1)WH (DCV N1) DCV/VFD Wiring (MAY NOT BE NEEDED DEPENDING ON OPTIONS) IF DCV IS NOT PRESENT, RD AND WH WIRES FROM SEPARATE 120VAC SOURCE MOCP = 10 AMPS FOR CONTROL WIRING DROP FOR DISCONNECT CONNECTION !ATTENTION ELECTRICIAN! CONNECT POWER TO THE DROP 1 2 5 6 3 4 IS FACTORY SUPPLIED 11 N WIRE COLOR YW - YELLOW GY - GRAY PR - PURPLE GR - GREENBL-BLUE BR - BROWN OR - ORANGE BK-BLACK WH - WHITE PK - PINK RD - RED SUPPLY 1.0HP-208V-3P-3.8FLA VFD: ESV751N02YXB571 MOTOR INFO ELECTRICAL INFORMATION MOTOR CIRCUIT MCA: 4.8A CONTROL CIRCUIT MCA: 1.0A MOTOR CIRCUIT MOP: 15A CONTROL CIRCUIT MOP: 15A DRAWING NUMBER JOB MODELSHIP DATEA8221654-2 8221654 - Arte Restaurant - Santa Ana, ... 9/5/2025 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 WIRE COLOR BK - BLACK BL - BLUE BR - BROWN OR - ORANGE RD - RED WH - WHITE YW - YELLOW GR - GREEN NOTES DENOTES FIELD WIRING DENOTES INTERNAL WIRING GY - GRAY Label Description Location Component Identification 23 PR - PURPLE PK - PINK Installed Options SW-01 R W B GR VA-01 BK N WH BK [BK][WH] N WH Spray Timer Overflow Switch Thermostat Internal Solenoid Valve SW-02 SW-01 VA-01 TI-01 [5-7] [6] [2] [5] GR D C SW-02 NC TI-01 A1 A2TORBK WH N TI-01 1815 SV BL BR OR PRESSURE OVERFLOW SWITCH To building drain Field Wired and Piped From building water supply Normally closed valve B W Roof line R WB R SWITCH AE Normally open valve Internal WaterSolenoid TIMER 15 A1 18 A2 16 P If cable is CM1NO2VL2BO2 NOTE: change BK->BR & WH->BL JUMPER A1 AND B1 FOR RZ7-FSH3VU23 TIMER JUMPER A1 AND B1 FOR TIMERRZ7-FSH3VU23 BR WH 11 BL 11 DRAWING NUMBER JOB MODELSHIP DATEEC8221654-2 8221654 - Arte Restaurant - Santa Ana, ... 9/5/2025 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 8221654 MASTER DRAWING AR Ar t e R e s t a u r a n t - S a n t a A n a , C A R e v 1 10 9 E a s t 4 t h S t r e e t , So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m Sa n t a A n a , C A , 9 2 7 0 1 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:42:06 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M204 HOOD INFORMATION D.L.R.C. 1 DCV-1111 WALL MOUNT IN SS BOX SS WALL MOUNT BOX 1 LIGHT 1 FAN SMART CONTROLS DCV EF MAU EXHAUST SUPPLY 3 3 5.000 1.000 208 208 14.5 3.8 NO TAG PACKAGE #LOCATION SWITCHES LOCATION QUANTITY OPTION FANS CONTROLLED FAN TAG TYPE ɸ HP VOLT FLA Field Connection Antennas Wired OR Paddle Field Connection to Router OR Ethernet switch Connection for Modbus Factory wired OR Field Wired Terminal Blocks for wired connection Cellular Module Compute module DESCRIPTION OF OPERATION: 8221654 Arte Restaurant - Santa Ana, ... DCV-1111 9/5/2025 INSTALL ECP #1-1 Demand Control Ventilation, w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans modulate based on duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature sensor shipped loose for field installation.Verify distance between VFD and Motor; additional cost could apply if distance exceeds 50 feet. BREAKER PANEL TO PRIMARY CONTROL PANEL Responsibility: Electrician BREAKER PANEL PRIMARY CONTROL PANEL BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED BREAKER 1PH CONTROL POWER. DO NOT WIRE TO GFCI OR SHUNT TRIP BREAKER. Hot Neutral H1 N1120 V 15 A Ground GND 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 WIRE TO VFD QUICK CONNECTOR BREAKER 3PH MCA: MOCP: LINE LINE Ground EF SM-1 GND L1 L2 LINE L3208 V 18.1 A 30 A BREAKER 3PH WIRE TO VFD QUICK CONNECTOR MCA: MOCP: LINE LINE 208 V Ground MAU SM-2 GND L4 L5 LINE L64.8 A 15 A CONTROL PANEL TO FANS Responsibility: Electrician PRIMARY PANEL FANS Load Wiring WIRE TO VFD QUICK WIRE TO DISCONNECT CONNECTOR MUST HAVE ITS OWN CONDUIT DO NOT SHARE CONDUIT! FLA: HP: VOLT: EF01 LOAD LEG 1 LOAD LEG 2 GND GROUND FAN: SM-1 LOAD LEG 3 U1 V1 W1 14.5 5.000 208 V Load Wiring BLACK BLACK BLACK GREEN WIRE TO VFD QUICK CONNECTOR WHITE RED FLA: HP: VOLT: MUST HAVE ITS OWN CONDUIT DO NOT SHARE CONDUIT! IF VFD MOUNTED IN 2ND PANEL, WIRE SF SIGNAL FROM PANEL WITH ECPM03. U2 V2 W2 LOAD LEG 1 LOAD LEG 2 LOAD LEG 3 GND GROUND MAU02FAN: SM-2 N1 120V NEUTRAL 120V HOT N1 3.8 1.000 208 V H1 CONTROL PANEL TO ACCESSORY ITEMS Responsibility: Electrician CONTROL PANEL COMPONENT ALL SWITCHES FACTORY WIRED CAT-5 CONNECTION CONTROL PANEL SWITCHES TO J4 CONTROL PANEL HOOD LIGHTS TO 1400 W MAX WIRE TO J-BOX ON TOP OF HOOD B1 W1 GND BLACK WHITE GREEN HOOD LIGHTS 1 WIRE DIRECTLY TO COMMUNICATION ROUTERCOMM MODULE. NET REQUIRES 1) DHCP 2) UDP PORT 1444 & 1445 OPEN FOR CAT-5 ETHERNET CONNECTION CONTROL PANEL WORLD WIDE TO WEB OUTBOUND TRAFFIC ONLY. -- WIRE TO CONTROL BOARD. INSTALL SENSOR IN ROOM AWAY FROM HEAT SOURCES. DO NOT INSTALL SENSOR CONTROL PANEL ROOM TEMP TO SENSOR ON THE CEILING GRID, SEE MANUAL. GROUPS: T1A T1B ROOM TEMP WIRE TO CONTROL BOARD. SENSOR MOUNTED IN HOOD CAPTURE CONTROL PANEL CAPTURE VOLUME TO SENSOR VOLUME. T2A T2B HOOD 1 CAPTURE 1 CONTROL PANEL GAS VALVE TO 120V ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. GAS N1 HOT TO GAS VALVE NEUTRAL GAS SOLENOID THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE SPECIFICATIONS CONTROL PANEL EXTERNAL SIGNAL FOR SHUNT TRIP ST TERMINAL IS ENERGIZED IN FIRE CONDITION. CONTROL PANEL EXTERNAL SIGNAL FOR CONTACTOR COIL KS TERMINAL IS DE-ENERGIZED IN FIRE CONDITION. ST N1 NEUTRAL FROM SHUNT COIL HOT TO SHUNT COIL SHUNT COIL KS N1 NEUTRAL_TO_CONTACTOR_COIL HOT_TO_CONTACTOR_COIL CONTACTOR_COIL SPARE CONTACTS WILL MAKE CONTROL PANEL ON/OFF WITH DRY CONTACT SUPPLY FAN COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. GROUP 1 SFC1 SFO1 COMMON NORMALLY OPEN SFC2 SFO2 COMMON NORMALLY OPEN WIRE TO ECPM03 TERMINALS. CONFIGURABLE OUTPUT. DCV SPEED (TOTAL) 0-10V OUTPUT ON PCB SEE ECPM03 OWNERS MANUAL. TO BMS + -VO+ VO- WIRE TO VFD TERMINAL STRIP. PROPORTIONAL TO FREQUENCY. VFD ANALOG (EACH VFD) 0-10V OUTPUT IN VFD SEE VFD OWNERS MANUAL. TO BMS + -30 2 CONTROL PANEL EXTERNAL TO SWITCH SIGNAL SWITCH THROUGH BMS WILL ACTIVATE ZONE1 FANS AND LIGHTS H1 IO1 BMS SWITCH C NO CONTROL PANEL GAS VALVE TO 24V DC ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. (NOT NEEDED IF USING 120V GAS VALVE). LGV N1D POSITIVE TO GAS VALVE NEGATIVE GAS SOLENOID CONTROL PANEL TO FIRE SYSTEM Responsibility: ALARM CONTRACTOR CONTROL PANEL COMPONENT CONTROL PANEL BUILDING SIGNAL FOR FIRE ALARM PANEL AL1 AL2 J9 BUILDING ALARM PANEL FIRE INPUT WIRE DIRECTLY TO CORE CIRCUIT BOARD. AL1 WILL MAKE AL2 IN FIRE CONDITION. CONTROL PANEL BUILDING SIGNAL FOR TROUBLE TROUBLE RELAY CONTACTS WILL MAKE TBC TO TBL IN TROUBLE CONDITION. BUILDING ALARM PANEL ALARM TBC TBL COMMON NORMALLY CLOSED CONTROL PANEL TO FIRE SYSTEM Responsibility: CERTIFIED INSTALLER CONTROL PANEL COMPONENT 21 22 FS-01 BK WH Fire Stat CONTROL PANEL MOUNTED FIRE TO DUCT DETECTION STAT(S) FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. 23 24 FS-02 BK WH Fire Stat FIRE STATS DESCRIPTION OF OPERATION: 8221654 Arte Restaurant - Santa Ana, ... DCV-1111 9/5/2025 INSTALL ECP #1-2 Demand Control Ventilation, w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans modulate based on duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature sensor shipped loose for field installation.Verify distance between VFD and Motor; additional cost could apply if distance exceeds 50 feet. CONTROL PANEL SYSTEM PULL TO FIRE STATION MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 is mounted on J10, remove the jumpers and wire in the supervised actuation loop. Microswitch MS-01 is optional for fire system interlock. Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master FS panel(s) in each manual activation loop for simultaneous activation. See Fire system drawings for more information. 101 102 103 104 AUX-01 AU1 AU2 PULL STATION MS-01 C NO Micro SW MAD-01 C NO Manual Actuation Device Adjacent FS Panel WIRE DIRECTLY TO CONTROL BOARD CAT-5 CONNECTIONCONTROL PANEL REMOTE FS TO MASTER PANEL EOL120A CORE PCBECPM03 PLACE END OF LINE PLUG IN EMPTY JACK. PN: EOL120A ADDITIONAL DEVICES MAY BE INLINE. UNLESS VFD, PCU, OR OTHER COMPONENT IN SERIES. J3 J5 J6 CONTROL PANEL MASTER FS TO PANEL WIRE TO LIKE TERMINALS IN ALL CORE PANELS THAT MUST ACTIVATE TOGETHER. SET MASTER & SLAVE DIP SWITCHES PER FIRE SYSTEM SHIELDED TWISTED PAIRINTERLOCK NETWORK MASTER CORE MANUAL. CA CB CC BLACK RED SHIELD CA CB CC DESCRIPTION OF OPERATION: 8221654 Arte Restaurant - Santa Ana, ... DCV-1111 9/5/2025 INSTALL ECP #1-3 Fire System #1 TANK FS - 4.0/4.0. Tank-based Fire Protection System equipped with Electronic Detection utilizing CORE board as a Listed Release Mechanism. Installed in Wall Mounted Utility Cabinet separate from prewire. Includes 12" box housing circuit board, batteries, and terminals for connection to main control panel. FS-1: MASTER DESCRIPTION OF OPERATION: 8221654 Arte Restaurant - Santa Ana, ... DCV-1111 9/5/2025 INSTALL ECP #1-4 Fire System #1 TANK FS - 4.0/4.0. Tank-based Fire Protection System equipped with Electronic Detection utilizing CORE board as a Listed Release Mechanism. Installed in Wall Mounted Utility Cabinet separate from prewire. Includes 12" box housing circuit board, batteries, and terminals for connection to main control panel. FS-1: MASTER SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 8221654 MASTER DRAWING AR Ar t e R e s t a u r a n t - S a n t a A n a , C A R e v 1 10 9 E a s t 4 t h S t r e e t , So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m Sa n t a A n a , C A , 9 2 7 0 1 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:42:08 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M205 HOOD INFORMATION D.L.R.C. DESCRIPTION OF OPERATION: FS-1: MASTER WH BK A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 MOTOR POWER CIRCUIT PANEL LID COMPONENT LIST LABEL DESCRIPTION ST-X varies Starter OL-X varies Overload C-X varies Contactor 120 VAC RELAY RA-x 24 VDC RELAY RD-x PS-1 MDP18-24A-1C Power Sup. 24VDC BK RA-x 34.110.0184.0 120V Relay DPDT WH RA-x 34.110.0184.0 120V Relay DPDT GR UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. N1 H1 DC - GN D DC + 8H1 7PCU 6ST 5KS 4KTS 3GAS 2AR1 1N1 120VJ9 5OV1 4SF1 3EF1 2B1 1IO1 120VJ7 AR1 H12x N12x B1 EF1 SF1 BK IO1 BK BK BK JUMPERW1 BK 14AWG BK 64 RD-1 BL PRDC+RO1 RD-x 34.110.0188.0 24VDC Light Relay BK WHSF1RA-2 RD-1 24V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 J6 N1N1 RO 1 FAN PANEL COOLING DRY CONTACTS (SHOWN DE-ENERGIZED) HOOD LIGHTS J3 ECPM03/DAISY CHAIN AR1 H1JUMPER FIRE SYSTEM BK BK BK GAS KS ST NOTE: Configure ECPM03 for CORE SM-1 SM-2 ECPM03 J10 IL 1 A IL 1 B JUMPER MAKE UP AIR INTERLOCK. 1 2 11 1 JUMPER 1 2 11 1 JUMPER NOTE: All items on ECPM03 J5 line to be daisy chained from one component to the next, with EOL120A at end of line. Place PN: EOL120A in empty RJ45 port. J3 ECPM03 or Previous EOL J5 MASTER CORE RA-2-1 SFC1 SFO1 14 AWG YW RA-2-2 SFC2 SFO2 14 AWG YW FACTORY WIRING SCHEMATIC CIRCUIT BOARDS ECPM03 SC-20 x 18 x 8.62 BOX CONTROL INPUT 120V H1=LINE, N1=NEUTRAL, 15A BREAKER. DO NOT CONNECT TO SHUNT TRIP BREAKER. SEE INSTALLATION SCHEMATIC FOR ADDITIONAL REQ. NOTE: IF VFD HAS 1PH 240V INPUT, USE L1 & L2 ONLY. IF VFD HAS 1PH 120V INPUT, USE L1 & N ONLY. LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN WH / B L BL H1N1 DC - DC + LN -+ PS-01 AC 24V GN D DCKSKSBKKS BK BK GAS ST BKEF1 PR WH GR / Y W WH / B L BL J4 J5 J1 ECPM03 SCADA WIRED BK RD +/24V -/GND DEST DEST ILB ILC ILA DEST DEST TO ETH CAT-5 SCADA SCADA Module SHDANT Wired to Master CORE (if applicable) Use shielded wire BK RD SD JUMPER ECPM03 J10 IL 2 A IL 2 B TERMINAL GAS USED FOR 120V POWERED GAS VALVES ONLY 8221654 Arte Restaurant ... FACTORY DCV-1111 9/5/2025 ECP #1-6 Demand Control Ventilation, w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans modulate based on duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature sensor shipped loose for field installation.Verify distance between VFD and Motor; additional cost could apply if distance exceeds 50 feet. BK BK BK BK BK BK BK BK BK BK BK BK U/T1 V/T2 W/T3 L1 L2 L3/N GR GR GND VFD: HP: MTR: FLA: P107: P108: P410: P150: P100: P194: P101: P131: P167: P103: P102: L1 L2 L3 12 AWG 3 PH 30 A 208 V U1 V1 W1 SM-1 ESV402N02TXB571 225 01 01 11 87 00 14.5 5.000 EF N/A N/A 62.8 53.3 0.0 GND BK BK BK BK BK BK BK BK BK BK BK BK U/T1 V/T2 W/T3 L1 L2 L3/N GR GR GND VFD: HP: MTR: FLA: P107: P108: P410: P150: P100: P194: P101: P131: P167: P103: P102: L4 L5 L6 14 AWG 3 PH 15 A 208 V U2 V2 W2 SM-2 ESV751N02YXB571 225 01 01 21 90 00 3.8 1.000 MAU N/A N/A 64.4 64.4 0.0 GND A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CORE FIRE PROTECTION COMPONENT LIST LABEL DESCRIPTION 120 VAC RELAY RA-x 24 VDC RELAY RD-x 24 VOLT BATTERY PACK 5 AMP FUSE RD SHIELDED TWISTED PAIR PCB-2 J3-2 J4-1 J3-11 J4-3 J4-2 J4-8 J4-9 J4-12 J3-14 J4-5 J3-13 J3-4 J4-6 J3-10 J2-1 J2-2 J2-3 J2-4 J7-2 J7-3 J7-1 J3-1 J3-3 RD RD BR RD MAX 16AWG RD BK ORRD PKRD BRRD RD OR/BL BK 18AWG BK BK J3-5 J1-1 J1-2 RD BK BK RD FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. + + RD BK BK RD Shield BK RD RS-485 CORE INTERLOCK NETWORK. Connection to other CORE Panels or Communication Module. See Installation Schematic for Connection. N1D 3xH1D3x DISCONNECT J1 21 22 23 24 16AWG WHN1 H1 PN: 1606-XLP-60EQ Adjust power supply to 27.5 Volts with an accurate Digital Volt Meter or with an HMI plugged into the CORE board. NL +- PS-02 60W GR BK GND PCB-2 PCBCORE-APP CORE PCB PS-02 1606-XLP-60E CORE POWER SUPPLY WS-x varies Water Solenoid LT-06 WL-1090D1-28V 24V Red Ind. Light LL-01 AQ5510 Surf. Level Sensor AA-01 SCE120LA3FP1B Audible Alarm PB-XX ZB4BA2/ZB4BZ1015 Prime/Reset Switch SW-04 BZ-2RQ1-A2 Tamper Switch SP-1 50000-805 Surfactant Pump PB-01 Prime / Reset RD-20 Trouble Relay RD-17 Fire Relay DRY CONTACTS (SHOWN DE-ENGERGIZED) AA-01 Audible Alarm SW-04 Door Tamper Switch C NO FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. Factory mounted hood sensors will be terminated at junction box on top of hood. GV-1 varies 24v DC Gas Valve INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition. RD-18-1 YW J3-16 J3-8 LT-6 R FIRE INDICATOR DIP Switch ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES. RD/GNRDRD-19 Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS Kill Switch, wire EKC and EKS terminals to like terminals in UDS panel. RD-19-1 EKC EST EKS YW INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition. RD-18-1 YW RD OR/BLRD-18 Auxiliary Interlock Relay FS-XX 12-F28021-000360 Duct Fire Sensor LT-05 WL-1090D3-28V 24V YLW Ind. Light PS-01 Station STI-SS2431 Remote Puill/Push FOR SHIPMENT J10-1 J10-2 J10-3 J10-4 RD BK BK RD 101 102 103 104 MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 should be mounted on J10 if there is no manual actuation device and no microswitch. MAD-01 C NO Manual Actuation Device MS-01 C NO Micro SW 1 2 3 4 5 6 7 8 SW 1 ON PUT END OF LINE PLUG IN EMPTY RJ45 J3 ECPM03 UNLESS PCU AFM OR OTHER COMPONENT IN SERIES. CAT-5 WIRING (MASTER ONLY) FIELD WIRED IF REMOTE PREWIRE RD-XX PLC-RPT-24DC/21 24VDC Phoenix Relay AUX-01 AU1 AU2 Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master CORE panel(s) in each manual activation loop for simultaneous activation. AU1/AU2 will have continuity for 10 seconds if adjacent panel goes into fire condition, activating this CORE Panel but allowing for a reset after 10 seconds. NOTE: AU1/AU2 terminals of CORE Panel should not be wired into its own manual activation loop.Adjacent CORE Panel Master CORE set DIP SW 8 to CLOSED position. Slave CORE with address 1 set DIP SW 8 to CLOSED position. All other CORES set DIP SW 8 OPEN. 18AWG LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN FIRE INDICATOR FAULT CONDITION FLASH CODES 2 Release Solenoid 3 Pressure Switch 4 Auxiliary Fault 5 Microcontroller Fault 6 N/A 7 Supervised Loop 8 Ground Fault 9 Surfactant Low 10 Battery Voltage Low 11 AC Power Failure 12 Door Tamper Switch 13 Test Mode 14 CORE Interlock Network 15 Fault on Hood in Interlock Network 16 Fault on PCU in Interlock Network FIRE ALARM SYSTEM DRY CONTACTS. Termials AL1 & AL2 make in FIRE. To Building Fire Alarm Panel J9 AL1 AL2 J3-7 FIRE SYSTEM DRY CONTACTS. Dry contacts will make C2 to AR2 when system is armed. RD-17-1 C2 AR2 14 AWG YW TROUBLE RELAY. Contact terminals TBC & TBL make if there is trouble. Contact terminals TBC & TOK make if the system is ok. RD-20-1 TBC TBL TOK YW RD PS OR J4-9 PS EWC-PRESSURE Pressure Switch PR RS SW-05-1 Test Armed 3 4 YW RS-1 RELEASE SOLENOID BLBR RD ORSW-05-3 Test Armed 3 4 J4-13 SW-05 ZB5AD2 TEST/ARM Switch RS2PRSW-05-2 Test Armed 3 4 YW PS-1 Pressure Switch WH PWS-01 24VDC 18W POWER 24VDC Power Suppl CA CB CC AU1AU1 AU2AU2 TR2 MAD-01 DEVICE MANUAL ACTIVATION GAS VALVES SHOULD BE WIRED TO MASTER CORE BOARD ONLY. RDRD GV-1 24V DC Gas ValveLGVPK TERMINAL LGV USED FOR 24VDC POWERED GAS VALVES ONLY. (2nd Contact) BK WHH1 N1 FAN PANEL COOLING *POWER FROM H1/N1 ONLY ON STANDALONE PACKAGE W/O ECP 8221654 Arte Restaurant ... FACTORY DCV-1111 9/5/2025 ECP #1-7 Fire System #1 TANK FS - 4.0/4.0. Tank-based Fire Protection System equipped with Electronic Detection utilizing CORE board as a Listed Release Mechanism. Installed in Wall Mounted Utility Cabinet separate from prewire. Includes 12" box housing circuit board, batteries, and terminals for connection to main control panel. FS-1: MASTER CONTROL PANEL. LCD INTERFACE. DUCT TEMPERATURE SENSOR. ROOM TEMPERATURE SENSOR. DEMAND CONTROL VENTILATION HOOD CONTROL PANEL SPECIFICATIONS: -CONTROLS SHALL BE LISTED BY ETL (UL 508A) AND SHALL COMPLY WITH DEMAND VENTILATION SYSTEM TURNDOWN REQUIREMENTS OUTLINED IN IECC 403.7.5 (2021). -THE CONTROL ENCLOSURE SHALL BE NEMA 1 RATED AND LISTED FOR INSTALLATION INSIDE OF THE EXHAUST HOOD UTILITY CABINET. THE CONTROL ENCLOSURE MAY BE CONSTRUCTED OF STAINLESS STEEL OR PAINTED STEEL. -TEMPERATURE PROBE(S) LOCATED IN THE EXHAUST DUCT RISER(S) SHALL BE CONSTRUCTED OF STAINLESS STEEL. -A DIGITAL CONTROLLER SHALL BE PROVIDED TO ACTIVATE THE HOOD EXHAUST FANS DYNAMICALLY BASED ON A FIXED DIFFERENTIAL BETWEEN THE AMBIENT AND DUCT TEMPERATURES SENSORS. THIS FUNCTION SHALL MEET THE REQUIREMENTS OF IMC 507.1.1. -A DIGITAL CONTROLLER SHALL PROVIDE ADJUSTABLE HYSTERESIS SETTINGS TO PREVENT CYCLING OF THE FANS AFTER THE COOKING APPLIANCES HAVE BEEN TURNED OFF AND/OR THE HEAT IN THE EXHAUST SYSTEM IS REDUCED. -A DIGITAL CONTROLLER SHALL PROVIDE AN ADJUSTABLE MINIMUM FAN RUN-TIME SETTING TO PREVENT FAN CYCLING. -VARIABLE FREQUENCY DRIVES (VFDS) SHALL BE PROVIDED FOR FANS AS REQUIRED. THE DIGITAL CONTROLLER SHALL MODULATE THE VFDS BETWEEN A MINIMUM SETPOINT AND A MAXIMUM SETPOINT ON DEMAND. THE DUCT TEMPERATURE SENSOR INPUT(S) TO THE DIGITAL CONTROLLER SHALL BE USED TO CALCULATE THE SPEED REFERENCE SIGNAL. -THE VFD SPEED RANGE OF OPERATION SHALL BE FROM 0% TO 100% FOR THE SYSTEM, WITH THE ACTUAL MINIMUM SPEED SET AS REQUIRED TO MEET MINIMUM VENTILATION REQUIREMENTS. -AN INTERNAL ALGORITHM TO THE DIGITAL CONTROLLER SHALL MODULATE SUPPLY FAN VFD SPEED PROPORTIONAL TO ALL EXHAUST FANS THAT ARE LOCATED IN THE SAME FAN GROUP AS THE SUPPLY FAN. -THE SYSTEM SHALL OPERATE IN PREP MODE DURING LIGHT COOKING LOAD OR COOL DOWN MODE WHEN SUFFICIENT HEAT REMAINS UNDERNEATH THE HOOD SYSTEM AFTER COOKING OPERATIONS HAVE COMPLETED. OPERATION DURING EITHER OF THESE PERIODS WILL DISABLE THE SUPPLY FANS AND PROVIDE AN EXHAUST FAN SPEED THAT IS EQUAL TO THE MINIMUM VENTILATION REQUIREMENT. -A DIGITAL CONTROLLER SHALL DISABLE THE SUPPLY FAN(S), ACTIVATE THE EXHAUST FAN(S), ACTIVATE THE APPLIANCE SHUNT TRIP, AND DISABLE AN ELECTRIC GAS VALVE AUTOMATICALLY WHEN FIRE CONDITION IS DETECTED ON A COVERED HOOD. -A DIGITAL CONTROLLER SHALL ALLOW FOR EXTERNAL BMS FAN CONTROL VIA DRY CONTACT (EXTERNAL CONTROL SHALL NOT OVERRIDE FAN OPERATION LOGIC AS REQUIRED BY CODE). -AN LCD INTERFACE SHALL BE PROVIDED WITH THE FOLLOWING FEATURES: A. ON/OFF PUSH BUTTON FAN & LIGHT SWITCH ACTIVATION. B. INTEGRATED GAS VALVE RESET FOR ELECTRONIC GAS VALVES (NO RESET RELAY REQUIRED). C. VFD FAULT DISPLAY WITH AUDIBLE & VISUAL ALARM NOTIFICATION. D. DUCT TEMPERATURE SENSOR FAILURE DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION. E. MIS-WIRED DUCT TEMPERATURE SENSOR DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION. F. A SINGLE LOW VOLTAGE CAT-5 RJ45 WIRING CONNECTION. G. AN ENERGY SAVINGS INDICATOR THAT UTILIZES MEASURED KWH FROM THE VFDS. SEQUENCE OF OPERATIONS: THE HOOD CONTROL PANEL IS CAPABLE OF OPERATING IN ONE OR MORE OF THE FOLLOWING STATES AT ANY GIVEN TIME: -AUTOMATIC: THE SYSTEM OPERATES BASED ON THE DIFFERENTIAL BETWEEN ROOM TEMPERATURE AND THE TEMPERATURE AT THE HOOD CAVITY OR EXHAUST DUCT COLLAR. FANS ACTIVATE AT A CONFIGURABLE TEMPERATURE DIFFERENTIAL THRESHOLD. DEPENDING ON THE JOB CONFIGURATION EACH FAN ZONE CAN BE CONFIGURED AS STATIC OR DYNAMIC. THESE TERMS REFER TO WHETHER A VARIABLE MOTOR (SUCH AS EC MOTORS OR VFD DRIVEN MOTORS) MODULATE WITH TEMPERATURE. IF THE PANEL IS EQUIPPED WITH VARIABLE SPEED FANS AND THE ZONE IS DEFINED AS "DYNAMIC", THESE WILL MODULATE WITHIN A USER-DEFINED RANGE BASED ON THE TEMPERATURE DIFFERENTIAL. PANELS EQUIPPED WITH VARIABLE SPEED FANS AND A FAN ZONE DEFINED AS "STATIC", FANS WILL RUN AT A SET SPEED CALCULATED FOR THE DRIVE. DEMAND CONTROL VENTILATION SYSTEMS ARE CAPABLE OF MODULATING EXHAUST AND MAKE UP AIR FAN SPEEDS PER THE REQUIREMENTS OUTLINED IN IECC 403.7.5 (2021). -MANUAL: THE SYSTEM OPERATES BASED ON HUMAN INPUT FROM AN HMI. -SCHEDULE: A WEEKLY SCHEDULE CAN BE SET TO RUN FANS FOR A SPECIFIED PERIOD THROUGHOUT THE DAY. THERE ARE THREE OCCUPIED TIMES PER DAY TO ALLOW FOR THE USER TO SET UP A TIME THAT IS SUITABLE TO THEIR NEEDS. ANY TIME THAT IS WITHIN THE DEFINED OCCUPIED TIME, THE SYSTEM WILL RUN AT MODULATION MODE AND FOLLOW THE FAN PROCEDURE ALGORITHM BASED ON TEMPERATURE DURING THIS TIME. DURING UNOCCUPIED TIME, THE SYSTEM WILL HAVE AN EXTRA OFFSET TO PREVENT UNINTENDED ACTIVATION OF THE SYSTEM DURING A TIME WHERE THE SYSTEM IS NOT BEING OCCUPIED. -OTHER: THE SYSTEM OPERATES BASED ON THE INPUT FROM AN EXTERNAL SOURCE (DDC, BMS OR HARD-WIRED INTERLOCK). FIRE:UPON ACTIVATION OF THE HOOD FIRE SUPPRESSION SYSTEM, THE EXHAUST FAN WILL COME ON OR CONTINUE TO TO RUN, THE HOOD MAKEUP AIR WILL SHUTDOWN, AND A SIGNAL WILL BE SENT FOR ACTIVATING THE SHUNT TRIP BREAKER PROVIDED BY THE ELECTRICIAN. FUEL GAS WILL SHUT OFF VIA A MECHANICAL/ELECTRICAL GAS VALVE ACTUATED BY THE HOOD FIRE SUPPRESSION SYSTEM. - SYSTEM DESIGN VERIFICATION (SDV) IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS HAD A COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL. TYPICALLY, THE SDV WILL BE PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE. ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP CHARGES. DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER. SHOULD A RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE SALES OFFICE WILL BE NOTIFIED. THERE WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 8221654 MASTER DRAWING AR Ar t e R e s t a u r a n t - S a n t a A n a , C A R e v 1 10 9 E a s t 4 t h S t r e e t , So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m Sa n t a A n a , C A , 9 2 7 0 1 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 10/24/2025 4:42:11 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 M206 HOOD INFORMATION D.L.R.C. GREASE DUCT & CHIMNEY SPECIFICATIONS: PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW" ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW" IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW" DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATION GUIDE. PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING MODEL "DW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" PER 12", HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12". DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN HORIZONTAL RUNS. IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. § CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF LISTED, PRE-FABRICATED ROUND GREASE EXHAUST DUCT TO REDUCE STATIC PRESSURE IN THE SYSTEM, MINIMIZE INSTALLATION AND INSPECTION TIMES, AND ENSURE DUCT IS LIQUID TIGHT CUSTOMER APPROVAL TO MANUFACTURE: ___' - ___" VERIFY CEILING HEIGHT HVAC DISTRIBUTION NOTE HIGH VELOCITY DIFFUSERS OR HVAC RETURNS SHOULD NOT BE PLACED WITHIN TEN (10) FEET OF THE EXHAUST HOOD. PERFORATED DIFFUSERS ARE RECOMMENDED. CONTROL PANEL. LCD INTERFACE. DUCT TEMPERATURE SENSOR. ROOM TEMPERATURE SENSOR. DEMAND CONTROL VENTILATION HOOD CONTROL PANEL SPECIFICATIONS: -CONTROLS SHALL BE LISTED BY ETL (UL 508A) AND SHALL COMPLY WITH DEMAND VENTILATION SYSTEM TURNDOWN REQUIREMENTS OUTLINED IN IECC 403.7.5 (2021). -THE CONTROL ENCLOSURE SHALL BE NEMA 1 RATED AND LISTED FOR INSTALLATION INSIDE OF THE EXHAUST HOOD UTILITY CABINET. THE CONTROL ENCLOSURE MAY BE CONSTRUCTED OF STAINLESS STEEL OR PAINTED STEEL. -TEMPERATURE PROBE(S) LOCATED IN THE EXHAUST DUCT RISER(S) SHALL BE CONSTRUCTED OF STAINLESS STEEL. -A DIGITAL CONTROLLER SHALL BE PROVIDED TO ACTIVATE THE HOOD EXHAUST FANS DYNAMICALLY BASED ON A FIXED DIFFERENTIAL BETWEEN THE AMBIENT AND DUCT TEMPERATURES SENSORS. THIS FUNCTION SHALL MEET THE REQUIREMENTS OF IMC 507.1.1. -A DIGITAL CONTROLLER SHALL PROVIDE ADJUSTABLE HYSTERESIS SETTINGS TO PREVENT CYCLING OF THE FANS AFTER THE COOKING APPLIANCES HAVE BEEN TURNED OFF AND/OR THE HEAT IN THE EXHAUST SYSTEM IS REDUCED. -A DIGITAL CONTROLLER SHALL PROVIDE AN ADJUSTABLE MINIMUM FAN RUN-TIME SETTING TO PREVENT FAN CYCLING. -VARIABLE FREQUENCY DRIVES (VFDS) SHALL BE PROVIDED FOR FANS AS REQUIRED. THE DIGITAL CONTROLLER SHALL MODULATE THE VFDS BETWEEN A MINIMUM SETPOINT AND A MAXIMUM SETPOINT ON DEMAND. THE DUCT TEMPERATURE SENSOR INPUT(S) TO THE DIGITAL CONTROLLER SHALL BE USED TO CALCULATE THE SPEED REFERENCE SIGNAL. -THE VFD SPEED RANGE OF OPERATION SHALL BE FROM 0% TO 100% FOR THE SYSTEM, WITH THE ACTUAL MINIMUM SPEED SET AS REQUIRED TO MEET MINIMUM VENTILATION REQUIREMENTS. -AN INTERNAL ALGORITHM TO THE DIGITAL CONTROLLER SHALL MODULATE SUPPLY FAN VFD SPEED PROPORTIONAL TO ALL EXHAUST FANS THAT ARE LOCATED IN THE SAME FAN GROUP AS THE SUPPLY FAN. -THE SYSTEM SHALL OPERATE IN PREP MODE DURING LIGHT COOKING LOAD OR COOL DOWN MODE WHEN SUFFICIENT HEAT REMAINS UNDERNEATH THE HOOD SYSTEM AFTER COOKING OPERATIONS HAVE COMPLETED. OPERATION DURING EITHER OF THESE PERIODS WILL DISABLE THE SUPPLY FANS AND PROVIDE AN EXHAUST FAN SPEED THAT IS EQUAL TO THE MINIMUM VENTILATION REQUIREMENT. -A DIGITAL CONTROLLER SHALL DISABLE THE SUPPLY FAN(S), ACTIVATE THE EXHAUST FAN(S), ACTIVATE THE APPLIANCE SHUNT TRIP, AND DISABLE AN ELECTRIC GAS VALVE AUTOMATICALLY WHEN FIRE CONDITION IS DETECTED ON A COVERED HOOD. -A DIGITAL CONTROLLER SHALL ALLOW FOR EXTERNAL BMS FAN CONTROL VIA DRY CONTACT (EXTERNAL CONTROL SHALL NOT OVERRIDE FAN OPERATION LOGIC AS REQUIRED BY CODE). -AN LCD INTERFACE SHALL BE PROVIDED WITH THE FOLLOWING FEATURES: A. ON/OFF PUSH BUTTON FAN & LIGHT SWITCH ACTIVATION. B. INTEGRATED GAS VALVE RESET FOR ELECTRONIC GAS VALVES (NO RESET RELAY REQUIRED). C. VFD FAULT DISPLAY WITH AUDIBLE & VISUAL ALARM NOTIFICATION. D. DUCT TEMPERATURE SENSOR FAILURE DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION. E. MIS-WIRED DUCT TEMPERATURE SENSOR DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION. F. A SINGLE LOW VOLTAGE CAT-5 RJ45 WIRING CONNECTION. G. AN ENERGY SAVINGS INDICATOR THAT UTILIZES MEASURED KWH FROM THE VFDS. SEQUENCE OF OPERATIONS: THE HOOD CONTROL PANEL IS CAPABLE OF OPERATING IN ONE OR MORE OF THE FOLLOWING STATES AT ANY GIVEN TIME: -AUTOMATIC: THE SYSTEM OPERATES BASED ON THE DIFFERENTIAL BETWEEN ROOM TEMPERATURE AND THE TEMPERATURE AT THE HOOD CAVITY OR EXHAUST DUCT COLLAR. FANS ACTIVATE AT A CONFIGURABLE TEMPERATURE DIFFERENTIAL THRESHOLD. DEPENDING ON THE JOB CONFIGURATION EACH FAN ZONE CAN BE CONFIGURED AS STATIC OR DYNAMIC. THESE TERMS REFER TO WHETHER A VARIABLE MOTOR (SUCH AS EC MOTORS OR VFD DRIVEN MOTORS) MODULATE WITH TEMPERATURE. IF THE PANEL IS EQUIPPED WITH VARIABLE SPEED FANS AND THE ZONE IS DEFINED AS "DYNAMIC", THESE WILL MODULATE WITHIN A USER-DEFINED RANGE BASED ON THE TEMPERATURE DIFFERENTIAL. PANELS EQUIPPED WITH VARIABLE SPEED FANS AND A FAN ZONE DEFINED AS "STATIC", FANS WILL RUN AT A SET SPEED CALCULATED FOR THE DRIVE. DEMAND CONTROL VENTILATION SYSTEMS ARE CAPABLE OF MODULATING EXHAUST AND MAKE UP AIR FAN SPEEDS PER THE REQUIREMENTS OUTLINED IN IECC 403.7.5 (2021). -MANUAL: THE SYSTEM OPERATES BASED ON HUMAN INPUT FROM AN HMI. -SCHEDULE: A WEEKLY SCHEDULE CAN BE SET TO RUN FANS FOR A SPECIFIED PERIOD THROUGHOUT THE DAY. THERE ARE THREE OCCUPIED TIMES PER DAY TO ALLOW FOR THE USER TO SET UP A TIME THAT IS SUITABLE TO THEIR NEEDS. ANY TIME THAT IS WITHIN THE DEFINED OCCUPIED TIME, THE SYSTEM WILL RUN AT MODULATION MODE AND FOLLOW THE FAN PROCEDURE ALGORITHM BASED ON TEMPERATURE DURING THIS TIME. DURING UNOCCUPIED TIME, THE SYSTEM WILL HAVE AN EXTRA OFFSET TO PREVENT UNINTENDED ACTIVATION OF THE SYSTEM DURING A TIME WHERE THE SYSTEM IS NOT BEING OCCUPIED. -OTHER: THE SYSTEM OPERATES BASED ON THE INPUT FROM AN EXTERNAL SOURCE (DDC, BMS OR HARD-WIRED INTERLOCK). FIRE:UPON ACTIVATION OF THE HOOD FIRE SUPPRESSION SYSTEM, THE EXHAUST FAN WILL COME ON OR CONTINUE TO TO RUN, THE HOOD MAKEUP AIR WILL SHUTDOWN, AND A SIGNAL WILL BE SENT FOR ACTIVATING THE SHUNT TRIP BREAKER PROVIDED BY THE ELECTRICIAN. FUEL GAS WILL SHUT OFF VIA A MECHANICAL/ELECTRICAL GAS VALVE ACTUATED BY THE HOOD FIRE SUPPRESSION SYSTEM. - SYSTEM DESIGN VERIFICATION (SDV) IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS HAD A COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL. TYPICALLY, THE SDV WILL BE PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE. ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP CHARGES. DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER. SHOULD A RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE SALES OFFICE WILL BE NOTIFIED. THERE WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R 7382032 MASTER DRAWING AR Ar t e R e s t a u r a n t - S a n t a A n a , C A 10 9 E a s t 4 t h S t r e e t , So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m Sa n t a A n a , C A , 9 2 7 0 1 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 7/18/2025 2:14:14 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 M207 HOOD INFORMATION K.T.R.C. GENERAL NOTES 1.BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS, ELEVATIONS AND CHARACTERISTICS OF ALL UTILITIES AND PIPING, AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 2.THE PLUMBING SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL CONFORM TO THE 2022 CPC AND AUTHORITIES HAVING JURISDICTION. IN CASE OF CONFLICTS WITH CODES, DRAWINGS, OR SPECIFICATIONS, THE MOST STRINGENT SHALL PREVAIL. 3.THE DRAWINGS WERE PREPARED WITH THE BEST STRUCTURAL AND ARCHITECTURAL INFORMATION AVAILABLE. IT IS UNDERSTOOD THAT EQUIPMENT LOCATIONS AND ROUTING OF PIPING MAY VARY FROM THAT SHOWN ON THE PLANS AS CONSTRUCTION PROCEEDS. IT IS THE CONTRACTORS RESPONSIBILITY TO: a.NOTIFY THE MECHANICAL ENGINEER OF CONSTRUCTION RESTRAINTS WHICH MAKE VARIATIONS FROM THE PLANS NECESSARY. b.COMPLETE ALL WORK INCLUDING THE VARIATIONS WITHOUT CHARGING EXTRAS TO THE BID CONTRACT. COMPLETION OF WORK MEANS THE JOB IS WORKING AND MEETS ALL CITY, COUNTY AND UNIFORM MECHANICAL, PLUMBING AND BUILDING CODE REQUIREMENTS. 4.THESE DRAWINGS DO NOT INCLUDE ALL NECESSARY SAFETY REQUIREMENTS. CONTRACTOR TO COMPLY TO THE SAFETY REQUIREMENTS SET FORTH BY THE LOCAL AUTHORITIES HAVING JURISDICTION. 5.THESE DRAWINGS ARE FOR BIDDING PURPOSES ONLY. THEY ARE ESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT MANY OFFSETS, BONDS, UNIONS, SPECIFIC FITTINGS AND EXACT LOCATIONS ARE NOT INDICATED. 6.THE PLUMBING CONTRACTOR SHALL PROVIDE THE WATER, SEWER AND STORM DRAIN SYSTEMS AND CONNECT TO EACH DESIGNATED POINT OF CONNECTIONS 5'-0" OUTSIDE OF THE BUILDING. ALL SEWER SYSTEM SHALL MEET THE REQUIRED INVERT ELEVATION SHOWN ON THE CIVIL DRAWINGS. PIPING BEYOND THIS POINT IS SPECIFIED UNDER ANOTHER SECTION OF THE SPECIFICATION AND SHALL BE AS SHOWN ON THE CIVIL DRAWINGS. 7.THE OWNER SHALL MAKE ALL ARRANGEMENTS WITH UTILITY COMPANIES FOR SERVICE AND CONNECTION AND SHALL MAKE APPLICATION FOR SERVICE AND PERMITS AND SHALL PAY ALL FEES AND CHARGES INCLUDING THE COST OF VAULTS AND METERS. 8.ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOID INTERFERENCE WITH ELECTRICAL EQUIPMENT, MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING, SKYLIGHT, ETC. 9.THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING ACCESS PANELS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN AND ELECTRICAL LIGHTING PLAN. 10.COORDINATE ALL LOCATIONS, SIZES AND ELEVATIONS OF ALL SLEEVES THROUGH WALLS, BEAMS, SLABS AND FOOTING WITH STRUCTURAL AND ARCHITECTURAL DRAWINGS. ALL PIPES SLEEVING THROUGH FOOTINGS SHALL HAVE A SLEEVE DIAMETER OF TWO PIPE SIZES OVER THE PIPE PASSING THROUGH THE FOOTING. 11.CONTRACTOR MUST NOT CUT, RELOCATE, COMPROMISE, DAMAGE OR OTHERWISE ALTER THE ROOF STRUCTURE. THE JOISTS WHICH OCCUR THROUGHOUT ALL THE MECH. BAY AREAS LIKE WISE MUST NOT BE ALTERED. 12.BEFORE FABRICATION OR INSTALLATION, THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF ALL MECHANICAL EQUIPMENT AND EQUIPMENT PROVIDED UNDER ANOTHER SECTION OF SPECIFICATIONS. EXACT ROUGH-IN LOCATIONS AND REQUIREMENTS SHALL BE COORDINATED IN FIELD. 13.CONNECTION BETWEEN INCOMPATIBLE MATERIALS ABOVE GRADE AND INSIDE BUILDING SHALL BE MADE WITH TWO (2) DIELECTRIC UNIONS SEPARATED BY A TWELVE INCH (12") SECTION OF RED BRASS PIPE. 14.ALL FLOOR AND WALL PENETRATIONS MUST BE SEALED WATERTIGHT AND VERMIN PROOF. 15.ALL EXTERIOR GAS COCKS, WATER SHUTOFF VALVES AND/OR SEWER CLEAN OUTS BELOW GROUND SHALL BE INSTALLED IN YARD BOXES WITH THE COVERS CONSPICUOUSLY MARKED "GAS", "WATER", AND "SEWER" RESPECTIVELY. 16.EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS. 17.SEE ARCHITECTURAL DRAWINGS FOR HANDICAP FIXTURE LOCATIONS AND MOUNTING HEIGHTS. INSULATE ALL EXPOSED HOT WATER AND DRAIN PIPING BELOW HANDICAP LAVATORIES AND SINKS WITH INSULATING TAPE AND OFFSET P-TRAP AGAINST WALL. ALL FLUSH VALVES FOR HANDICAP SHALL BE LOCATED ON HANDICAP WHEELCHAIR ACCESS SIDE OF STALL. 18.ALL WASTE, SOIL AND VENT PIPING SHALL SLOPE AT 2% UNLESS OTHERWISE INDICATED. 19.ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON-ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL. 20.PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BASE BID. HE SHALL FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS AND FUTURE WORK TO BE DONE. HE SHALL INCLUDE ALL HIS SITE INFORMATION AND CONDITIONS WITHIN HIS BASE BID. HE SHALL BE RESPONSIBLE FOR COMPLETE AND FULLY FUNCTIONING PLUMBING SYSTEMS. 21.PLUMBING CONTRACTOR SHALL COORDINATE COMPLETE PLUMBING INSTALLATION AND REQUIREMENTS PRIOR TO BASE BID WITH ALL LOCAL DISTRICTS AND GOVERNING AUTHORITIES. INCLUDE ALL FINDINGS WITHIN THE BASE BID. 22.PROVIDE RECIRCULATION PUMP FOR HOT WATER WHEN THE HOT WATER PIPE IS OVER 50'. 23.PROVIDE TRAP SEAL PRIMER FOR FLOOR DRAIN SUBJECT TO INFREQUENT USE. 24.ALL PLUMBING, AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS GREAT EXTENT AS POSSIBLE. ALL EXPOSED CONDUITS, PLUMBING, ETC. SHALL BE INSTALLED AT LEAST 6" OFF FLOOR AND 3/4" FROM WALLS USING STANDOFF BRACKETS. 25.PLUMBING OR PIPING CANNOT BE INSTALLED ACROSS ANY AISLE WAY, TRAFFIC AREA OR DOOR OPENING. 26.MULTIPLE RUNS OR CLUSTERS OF PIPELINES SHALL BE FURRED IN OR ENCASED IN AN APPROVED SEALED ENCLOSURE. 27.APPROVED BACKFLOW PREVENTION DEVICES SHALL BE PROPERLY INSTALLED UPSTREAM OF ANY POTENTIAL HAZARD BETWEEN THE POTABLE WATER SUPPLY AND A SOURCE OF CONTAMINATION. HOSES SHALL NOT BE ATTACHED TO A FAUCET OR HOSE BIBB UNLESS AN APPROVED BACKFLOW PREVENTER IS PROVIDED. 28.ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING AGENCY. 29.EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) INCHES ABOVE THE FLOOD-LEVEL RIM OF THE FIXTURE SERVED BEFORE OFFSETTING HORIZONTALLY OR BEFORE BEING CONNECTED TO ANY OTHER VENT. 30.EACH VENT SHALL TERMINATE NOT LESS THAN 10 FEET FROM, OR AT LEAST 3 FEET FROM, OR NOT LESS THAN 3 FEET ABOVE, ANY OPENABLE WINDOW, DOOR, OPENING, AIR INTAKE, OR VENT SHAFT, OR NOT LESS THAN 3 FEET IN EVERY DIRECTION FROM ANY LOT LINE. 31.FIELD VERIFY ALL EXISTING PLUMBING CONDITIONS AND EXISTING/NEW HVAC PLUMBING CONNECTIONS PRIOR TO BIDDING AND START OF WORK. 32.IN THE EVENT THAT THE PLANS DO NOT REPRESENT FIELD CONDITIONS, CONTACT THE OWNER, ARCHITECT, OR DESIGNATED ENGINEER DESIGNER PRIOR TO START OF ANY WORK. 33.CAP ALL DOMESTIC WATER PIPING THAT IS SERVING A PLUMBING FIXTURE THAT IS BEING DEMOLISHED. 34.NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE DISINFECTED PRIOR TO USE. CONTRACTOR SHALL PROVIDE A SIGNED WRITTEN DECLARATION TO THE INSPECTOR AT TIME OF INSPECTION THAT POTABLE WATER SYSTEM HAS BEEN DISINFECTED. 35.EXISTING BUILDING SEWERS AND BUILDING DRAINS MAY BE USED IF SUCH SEWERS HAVE BEEN PROPERLY MAINTAINED AND FOUND UPON EXAMINATION AND TEST PERFORMED BY THE OWNER OR OWNER'S DESIGNATED AGENT THAT THEY ARE IN WORKING CONDITION AND FREE FROM ANY DEFECT. 36.CLEANOUTS SHALL BE INSTALLED AS PER SEC. 707.0 & 719.0 OF THE PLUMBING CODE. PLUMBING FIXTURE SCHEDULE MARK ITEM HW CW VENT WASTE DESCRIPTION WH WATER HEATER 3/4"3/4"----A.O. SMITH DRE-52-24 ELECTRIC TANK TYPE WATER HEATER. 50 GAL. 24 KW INPUT. EXPANSION TANK (ZURN MODEL XT-18, 4.8 GAL.) INSTALLED WITH WATER HEATER. EQUIVALENT FIXTURE ACCEPTABLE. WC TANK TYPE WATER CLOSET --3/4"2"4"AMERICAN STANDARD CADET PRO ELONGATED ADA COMPLIANT TANK WATER CLOSET WITH OPEN FRONT ELONGATED TOILET SEAT. 1.28 GPF. EQUIVALENT ACCEPTABLE. URL WALL MOUNTED URINAL --1"2"2"AMERICAN STANDARD WALL MOUNTED URINAL WASHBROOK FLOWISE 0.125 GPF WITH MANUAL FLUSH VALVE 6590.503. EQUIVALENT FIXTURE ACCEPTABLE. LAV WALL MOUNTED LAVATORY 1/2"1/2"2"2" AMERICAN STANDARD 0356.041 SINK W/ 6055.165. SELECTRONIC PROXIMITY FAUCET. 0.5 GPM. ADA COMPLIANT. EQUIVALENT ACCEPTABLE. INSTALL WITH POWERS #LFG480 MIXING VALVE(ASSE 1070 LISTED). FD FLOOR DRAIN ----2"2"ZURN Z415B W/SEDIMENT BUCKET. TRAP PRIMER CONNECTION WHERE REQUIRED BY CODE. EQUIVALENT FIXTURE ACCEPTABLE. FS FLOOR SINK ----2"2"ZURN Z-1901, 12" SQUARE TOP, HALF GRATE COVER AND 8" DEEP WITH DOME STRAINER. EQUIVALENT FIXTURE ACCEPTABLE. WCO WALL CLEANOUT ------LINE SIZE ZURN Z1441 WALL CLEANOUT W/SMOOTH ACCESS COVER EQUIVALENT FIXTURE ACCEPTABLE. FCO FLOOR CLEANOUT ------LINE SIZE ZURN Z1400-B FLOOR CLEANOUT EQUIVALENT FIXTURE ACCEPTABLE. TP TRAP PRIMER --1/2"----WATTS SERIES TP300 TRAP PRIMER WITH INTEGRAL VACCUM BREAKER. MOUNT IN WALL WITH ACCESS PANEL&SHUTOFF VALVE. EQUIVALENT FIXTURE ACCEPTABLE. PRV PRESSURE REDUCING VALVE --1-1/4"----ZURN MODEL 500XL WATER PRESSURE REDUCING VALVE WITH INTEGRAL BY-PASS CHECK VALVE. EQUIVALENT FIXTURE ACCEPTABLE. (E) GI GREASE INTERCEPTOR ------4"JENSEN PRECAST 1500 GALLON GREASE INTERCEPTOR .MODEL MU1500 EE-G2 . WITH EXISTING SAMPLE BOX. EXISTING TO REMAIN. SHEET INDEX P000 P001 P002 P100 P200 TP00 ·EXISTING SHELL BUILDING TO RESTAURANT CONVERSION. ·PROVIDE NEW PLUMBING FIXTURES/CONNECTIONS THROUGHOUT THE SPACE. ·NEW WATER HEATER TO BE INSTALLED. PLUMBING NOTES & SCHEDULES PLUMBING DETAILS PLUMBING SPECIFICATION SHEETS WASTE & VENT PLAN TITLE 24 P300 PLUMBING ISOMETRIC DIAGRAM SCOPE OF WORK WATER & GAS PLAN PLUMBING SPECIFICATION 1.CLEANOUTS PROVIDE CLEANOUTS WITH BRASS SCREW PLUG AT ALL CHANGES OF DIRECTION TO PERMIT ROUTING OF ALL SEWERS. ALL CLEAN OUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THE CONTRACTOR SHALL COORDINATE ALL CLEAN OUT LOCATIONS OF EQUIPMENT, CABINETS, ETC., WITH THE ARCHITECT PRIOR TO ANY INSTALLATION. 2.VALVES EVERY PLUMBING FIXTURE SHALL BE INDEPENDENTLY VALVED. 3.TESTING ALL SEWERS AND WATER PIPING SHALL BE PROPERLY TESTED TO THE SATISFACTION OF THE ARCHITECT AND THE LOCAL BUILDING INSPECTOR. 4.EXCAVATION AND BACK FILLING TRENCHES SHALL BE BACK FILLED AND SETTLED BY PUDDLING. NO PIPE SHALL BE LESS THAN 12" BELOW FINISH GRADE. 5.PIPING SUPPORTS ALL PIPING TO BE SUPPORTED WITH HANGERS AND BRACKETS WHICH PROVIDE ISOLATION FROM FRAMING. CONTACT BETWEEN PIPE AND SUPPORT TO BE LINED WITH PLASTIC OR FELT. NOTE: 1.ABS AND PVC INSTALLATIONS ARE LIMITED TO NOT MORE THAN TWO STORIES OF AREAS OF RESIDENTIAL ACCOMMODATION. 2.ABS/PVC VENT TERMINATIONS UP THROUGH THE ROOF EXPOSED TO SUNLIGHT ARE REQUIRED TO BE PROTECTED BY WATER BASED SYNTHETIC LATEX PAINTS. INSIDE NATURAL SANITARY WASTE SANITARY GAS VENT INSIDE OUTSIDE EXPOSED CONCEALED OUTSIDE CO P P E R - T Y P E " M " WATER DOMESTIC SERVICE: PIP E M A T E R I A L : OUTSIDE INSIDE CO P P E R - T Y P E " L " CO P P E R - T Y P E " K " SC H E D . 4 0 P V C , D W V REMARKS: INDIRECT WASTE INSIDE INSIDE* PIPE MATERIAL SCHEDULE *USE COPPER TYPE "M" FOR CONDENSATE SC H E D . 4 0 BL A C K S T E E L CA S T I R O N S O I L W / H . G . OR " I D E A L " F I T T I N G S SC H E D U L E 4 0 GA L V A N I Z E D S T E E L SC H E D . 4 0 A B S , D M V GSOV W/ AUTOMATIC GAS SHUT-OFF VALVE WITH FLR NTS IE CFH DN FF POC (N) FCO/COTG WCO SOV CUBIC FEET PER HOUR FINISHED FLOOR ELEVATION FLOOR NOT TO SCALE INVERT ELEVATION DOWN POINT OF CONNECTION NEW FLOOR CLEANOUT/CLEANOUT TO GRADE WALL CLEANOUT COLD WATER SHUT-OFF VALVE ABBR. PLUMBING LEGEND HW G CD T&P V GW S OR W CW SYMBOL DOMESTIC COLD WATER SOIL OR WASTE BELOW FLOOR LOW PRESSURE GAS DOMESTIC HOT WATER PRIMARY CONDENSATE DRAIN TEMPERATURE & PRESSURE VENT DESCRIPTION HWR DOMESTIC HOT WATER RETURN C.V.CHECK VALVE PRV PRESSURE REDUCING VALVE BALANCING VALVE SOC SHUT-OFF COCK (GAS) TMV TEMPERATURE MIXING VALVE VTR VENT TO ROOF BLV CP RECIRCULATION PUMP CW COLD WATER STUB-IN HW HOT WATER STUB-IN XSS XGW EXISTING WASTE/SANITARY SEWER EXISTING GREASE WASTE XCW FW EXISTING COLD WATER FILTERED WATER (E)EXISTING (R)RELOCATED, EXISTING XG EXISTING GAS XHW EXISTING HOT WATER GREASE WASTE BELOW FLOOR GSOV GAS SHUT-OFF VALVE CWV COMBINATION WASTE & VENT BELOW COLD WATER OUTLETCWO DCO DOUBLE CLEANOUT BACKFLOW PREVENTERBFP SCW SOFTEN COLD WATER IND INDIRECT WASTE MPG MEDIUM PRESSURE GAS HOT WATER OUTLETHWO NONRESIDENTIAL NOTES LAVATORIES IN RESTROOMS OF PUBLIC FACILITIES SHALL BE EQUIPPED WITH OUTLET DEVICES THAT LIMIT THE FLOW OF HOT WATER TO A MAXIMUM OF 0.5 GPM OR WITH SELF-CLOSING FAUCETS THAT LIMIT DELIVERY TO A MAXIMUM OF 0.2 GALLONS OF HOT WATER FOR RECIRCULATING SYSTEMS, AND SHALL BE EQUIPPED WITH DEVICES THAT LIMIT THE OUTLET TEMPERATURE TO A MAXIMUM OF 110 °F. CA GREEN BUILDING NOTES 5.303.2 PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATE VALUES SHOWN IN TABLES A5.303.2.2. 5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTINGS (FAUCETS AND SHOWERHEADS) SHALL COMPLY WITH THE FOLLOWING: 5.303.3.1 WATER CLOSETS. THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATER SENSE SPECIFICATION FOR TANK-TYPE TOILETS. NOTE:THE EFFECTIVE FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONE FULL FLUSH. 5.303.3.2 URINALS. THE EFFECTIVE FLUSH VOLUME OF WALL-MOUNTED URINALS SHALL NOT EXCEED 0.125 GALLONS PER FLUSH.THE EFFECTIVE FLUSH VOLUME OF FLOOR-MOUNTED URINALS SHALL NOT EXCEED 0.5 GALLONS PER FLUSH. 5.303.3.4.1 NONRESIDENTIAL LAVATORY FAUCETS. LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 0.5 GALLONS PER MINUTE AT 60 PSI. 5.303.4.2 KITCHEN FAUCETS. KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE AT60 PSI, AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. 5.303.6 PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE 2022 CALIFORNIA PLUMBING CODE, AND SHALL MEET THE APPLICABLE STANDARDS REFERENCED IN TABLE 1401.1 OF THE 2022 CALIFORNIA PLUMBING CODE AND IN CHAPTER 6 OF THIS CODE. PIPE INSULATION THICKNESS FLUID TEMP. RANGE (°F) CONDUCTIVITY RANGE (BTU-"/HR PER SQFT/°F) INSULATION MEAN RATING TEMP. (°F) NOMINAL PIPE DIAMETER (") INSULATION THICKNESS REQUIRED (") <1 1 TO <1.5 1.5 TO <4 4 TO <8 8 AND LARGER 251-350 350< 201-250 141-200 105-140 40-60 <40 SPACE COOLING SYSTEMS (CHILLED WATER, REFRIGERANT AND BRINE) SPACE HEATING, HOT WATER SYSTEMS AND SERVICE WATER HEATING SYSTEMS 0.32-0.34 0.29-0.31 0.27-0.30 0.25-0.29 0.22-0.28 0.21-0.27 0.20-0.26 250 200 150 125 100 75 50 4.5 3.0 2.5 1.5 1.0 1.0 5.0 4.0 2.5 1.5 1.5 1.5 5.0 4.5 2.5 2.0 1.5 1.5 5.0 4.5 3.0 2.0 1.5 1.5 5.0 4.5 3.0 2.0 1.5 1.5 EXCEPTIONS: (1) FACTORY-INSTALLED PIPING WITHIN SPACE CONDITIONING EQUIPMENT; (2) PIPING THAT CONVEYS FLUIDS THAT HAVE A DESIGN OPERATING TEMPERATURE RANGE BETWEEN 60 DEGREES AND 105 DEGREES FAHRENHEIT; (3) WHERE THE HEAT GAIN OR HEAT LOSS TO OR FROM PIPING WITHOUT INSULATION WILL NOT INCREASE BUILDING SOURCE ENERGY USE; (4) PIPING THAT PENETRATES FRAMING MEMBERS SHALL NOT BE REQUIRED TO HAVE PIPE INSULATION FOR THE DISTANCE OF THE FRAMING PENETRATION. METAL PIPING THAT PENETRATES METAL FRAMING SHALL USE GROMMETS, PLUGS, WRAPPING OR OTHER INSULATING MATERIAL TO ASSURE THAT NO CONTACT IS MADE WITH THE METAL FRAMING. SPACE-CONDITIONING AND SERVICE WATER-HEATING SYSTEM SHALL BE INSULATED IN ACCORDANCE WITH THE FOLLOWING TABLE: NONRES 0.5 RES 0.75 1.01.0 1.0 PIPE INSULATION RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 12/2/2025 12:13:03 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 PL A N C H E C K R E V . 1 2 / 0 2 / 2 0 2 5 P000 E.H.D.T. N.T.S. PLUMBING NOTES & SCHEDULES PIPE INSULATION INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS PIPE INSULATION PROTECTION SHIELD. USE 16 GAUGE SHEET STEEL, 2 PIPE DIAMETERS LONG, 120 DEGREES SUPPORT, OR GRINNEL FIGURE 167. HANGER ROD PROVIDE GALV. STEEL SHIELD FOR ALL INSULATED PIPE.VERIFY INSULATION THICKNESS WHEN SIZING HANGERS AND SHIELDS. ADJUSTABLE BAND HANGER FOR PIPE 3-1/2" AND SMALLER AND CAST IRON PIPE 2" AND SMALLER HANG PIPE LARGER THAN 4" FROM TOP OF JOISTS ONLY AT PANEL POINT SIDE BEAM CONNECTOR ATTACHED TO TOP CHORD OF WOOD TRUSS PROVIDE COPPER COATED HANGERS WHERE HANGERS CONTACT BARE COPPER PIPE PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES. SLOPE ALL WATER PIPING SLIGHTLY TOWARD DRAINABLE LOCATIONS. HANGER SPACING FOR PIPE SIZES: AS INDICATED IN TABLE. CAST IRON: 10' AND WITHIN 1'-0" OF ALL JOINTS. ROD SIZES FOR PIPE SIZE: 1/2" TO 4" = 3/8", 5" TO 8" = 1/2", 10" TO 12" = 5/8". LOCATE HANGERS WITHIN 1'-0" OF VALVES AND FITTINGS. PROVIDE SUPPLEMENTAL STEEL STRUTS BETWEEN JOISTS IF REQUIRED. LOCATE HANGERS WITHIN 1'-0" OF EQUIPMENT CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY. CHAINS AND PERFORATED STRAP IRON AND STEEL ARE NOT ACCEPTABLE. DO NOT SUSPEND PIPE FROM JOIST BRACING MEMBERS. REFER TO CODES AND SPECIFICATIONS FOR FURTHER INFORMATION. PROVIDE SEISMIC BRACING AS REQUIRED BY LOCAL AUTHORITIES. PROVIDE FIBERGLASS INSULATION WITH ALL-SERVICE JACKET WITH VAPOR BARRIER ON ALL SIZES OF HOT AND COLD WATER AND CONDENSATE PIPING. GAS PIPING SHALL BE KEPT A MIN. OF 6" ABOVE GRADE OR STRUCTURE. GAS PIPE SUPPORT STEEL PIPE, NOMINAL SIZE OF PIPE (INCHES) SPACING OF SUPPORTS (FEET) NOMINAL SIZE OF TUBING SMOOTH-WALL (INCHES O.D.) SPACING OF SUPPORTS( FEET) 1/2 6 1/2 4 3/4 OR 1 8 5/8 OR 3/4 6 1-1/4 OR LARGER (HORIZONTAL)10 7/8 OR 1 (HORIZONTAL)8 1-1/4 OR LARGER (VERTICAL EVERY FLOOR LEVEL 1 OR LARGER (VERTICAL) EVERY FLOOR LEVEL SCALE N.T.S 6'1-1/2" 10'4" 10' 10' 10' 2-1/2" 3" 2" ALL-THREAD ROD CO P P E R P I P E HA N G E R S P A C I N G 6'1/2"1/2" 6'3/4" 6' 6' 1-1/4" 1" PI P E S I Z E WOOD STRUCTURE CL LC STEEL STRUCTURE SECTION PIPE HANGER DETAIL (BELOW ROOF) WATER PIPE SUPPORT: 1 PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES NOT SERVED WITH A FLOOR CLEANOUT: LOCATED ABOVE FIXTURE FLOOR RIM WITHIN 4'-0" OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. RISER LENGTH AS REQUIRED LONG SWEEP AT END OF LINE OR COMBINATION WYE AND EIGHTH BEND IN RUN OF LINE. INSTALL ESCUTCHEON PLATE AT CLEANOUT TEE. PROVIDE SCREWED COUNTER-SINK BRONZE PLUG FOR CLEANOUT TEE WITH TAPPED THREAD & TEE JOINT COMPOUND CONCRETE FLR. WASTE OR VENT TO ABOVE PLUMBING WALL OR COLUMN REFER TO FLOOR PLANS PROVIDE WATERPROOFING SCALE N.T.S NOTE: DIRECTION OF FLOW WALL CLEANOUT DETAIL 2 ELMDOR/STONEMAN, MODEL #1100-4 SEALANT SHALL BE APPLIED AROUND PIPE OPENING THRU COUNTER FLASHING SLEEVE FOR WATER TIGHT SEAL BUILT-UP ROOFING APPLY PERMASEAL WATER PROOFING COMPOUND AROUND PIPE, COUNTER FLASHING SLEEVE & FLASHING FOR WATER TIGHT SEAL. SEAMLESS LEAD FLASHING OVER STEEL REINFORCED BOOT INSTALL (3) VANDAL- PROOF SET SCREWS 8" MIN. BOOT HEIGHT 5" MIN. 12" MIN. PIPE THRU ROOF SCALE N.T.S 2" MIN. PIPING THRU ROOF DETAIL 3 FILL TANK WITH AIR PRESSURE TO MATCH WATER PRESSURE, THEN OPEN VALVE WELDED STEEL EXPANSION TANK WITH POLYPROPYLENE LINING, FDA APPROVED FOR DOMESTIC WATER SERVICE PIPE UNION: DIELECTRIC IF REQUIRED FOR DISSIMILAR METALS BUTYL DIAPHRAGM FROM CW SUPPLY TO HEATER, NO INTERVENING VALVES PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED. EXPANSION TANK DETAIL SCALE N.T.S SEISMIC STRAPPING FOR BRACING IN SEISMIC AREAS 7 TRAP PRIMER DETAIL CW LINE ABV. CLG. 1/2" CW TRAP PRIMER LINES IN WALL (TYPE 'L' COPPER) TRAP WALL FINISH FLOOR FLOOR DRAIN SCALE N.T.S 4 REQUIRED BY CODE. ACCESSIBLE LOCATION OR AS MANUAL SHUTOFF VALVE IN AN FURNISH AND INSTALL A 1/4 TURN INTERCONNECT W/HOOD EXHAUST FANS INSTALLED BY PLUMBING CONTRACTOR. SEE PLAN OR RISER GAS SOLENOID VALVE AND BY-PASS FURNISHED BY HOOD SUPPLIER, FOR SIZE TO EQUIPMENT OR MANIFOLD G IF REQUIRED BYPASS PIPING AUTOMATIC GAS SOV SCALE N.T.S 5 TO FINISHED FLOOR. 2" 1" AIR GAP. FLOOR SINK RIGID CONNECTION. SCALE N.T.S3-COMPARTMENT SINK DETAIL 3 COMP SINK 8 GREASE WASTE. SCALE N.T.SELECTRIC WATER HEATER DETAIL CW IN HW OUT THERMAL EXPANSION TANK VACUUM RELIEF VALVE DIELECTRIC UNION (TYP) ASME T&P RELIEF VALVE. TERMINATE DISCHARGE FULL SIZE OF VALVE CONNECTION TO CHECK VALVE 1/4 TURN BALL VALVE TANK TYPE WATER HEATER FOR SEISMIC APPLICATIONS: PROVIDE 1/8" THICK X 2"W. 22 GA. STEEL STRAP SECURED TO 3/8" THICK X 6"W. STEEL PLATE ANCHORED TO MINIMUM (4) STUDS W/ 1/2"Ø ANCHOR BOLTS OR LAG SCREWS (NUTS AND BOLTS FOR STEEL STUDS) HW OUT WATER HEATER SHALL BE STRAPPED TO THE BUILDING AT THE 1/3-POINT TOP AND BOTTOM WATER HEATER STAND (4-INCH HIGH, COVED PLATFORM/CURB OR AT LEAST 6-INCH HIGH, SMOOTH, EASILY CLEANABLE LEGS.) 4 MOP SINK. RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 12/2/2025 12:13:04 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 PL A N C H E C K R E V . 1 2 / 0 2 / 2 0 2 5 P001 E.H.D.T. PLUMBING DETAILS N.T.S. 4 RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 12/2/2025 12:13:04 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 PL A N C H E C K R E V . 1 2 / 0 2 / 2 0 2 5 P002 E.H.D.T. PLUMBING SPECIFICATION SHEETS N.T.S. UP 18x36 5 TIER 18x60 5 TIER 18 x 2 4 5 T I E R A.03 18x54 5 TIER 18 x 3 6 5 T I E R 18 x 3 6 5 T I E R #KEYED PLAN NOTES: GENERAL NOTES: 1.IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION, CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATION REFLECTING ACTUAL CONDITIONS. 2.ALL PLUMBING FIXTURES AND CONNECTIONS ARE NEW UNLESS NOTED AS EXISTING. 3.COORDINATE FLOOR SINK AND DRAIN LOCATIONS, IF ANY, WITH ARCHITECTURAL AND FOOD SERVICE PLAN PRIOR TO ROUGH-IN. 4.ALL UNDERGROUND WASTE PIPING SHALL BE SLOPED AT A 2% GRADE UNLESS OTHERWISE NOTED. 5.PROVIDE WALL CLEAN OUTS TO ALL SINK AND URINAL FIXTURES. WASTE & VENT PLAN 1.P.O.C. TO EXISTING 4" SANITARY WASTE WITH NEW PIPING. FIELD VERIFY ALL EXISTING CONDITIONS, SIZE, AND LOCATION PRIOR TO START OF THIS WORK. 2.P.O.C. TO EXISTING 4" SANITARY VENT WITH NEW PIPING. FIELD VERIFY ALL EXISTING CONDITIONS, SIZE, AND LOCATION PRIOR TO START OF THIS WORK. 3.P.O.C. TO EXISTING 4" GREASE WASTE WITH NEW PIPING. DRAIN TO EXISTING 1500 GALLON GREASE INTERCEPTOR LOCATED IN LEVEL B1. FIELD VERIFY ALL EXISTING CONDITIONS, SIZE, AND LOCATION PRIOR TO START OF THIS WORK. 4.WATER HEATER T&P VALVE DRAIN TO MOP SINK. 5.BAR SINK, HS-2, DUMP SINK, 3-COMP SINK, PREP SINK, ICE BIN AND ICE MACHINE INDIRECTLY DRAIN TO ADJACENT FLOOR SINKS. 3 2 1 FS FS FSFSFS (E) 4"GW FCO FD URL FS 4"W; MINIMUM 2% SLOPE WC WC LAV LAV TYP. 4"W FOR WC TYP. 2"W FOR LAV WCO ICE BIN DUMP SINK ICE BIN HS-2 BAR SINK MOP WH ABOVE MOP4 PREP 3-COMP 5 2"V (E) 4"GW 2"V 2"V 5 5 5 5 5 HS-1 3 4"W 3 (E) 4"GW WCO 4"W; MINIMUM 2% SLOPE 4"W; MINIMUM 2% SLOPE 2"V 2"W HS-1 2"V FS TYP. 2"W FOR FS ICE BIN 5 4"W; MINIMUM 2% SLOPE 2"W 2"V FD 2"V 5 2"GW 2"V 3" TRAP ARM 2"W 2"GW 2"GW 3"W3"W ICE MACHINE 5 3"V 3"V 3"V 3"V RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 12/2/2025 12:13:08 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 PL A N C H E C K R E V . 1 2 / 0 2 / 2 0 2 5 P100 1/4" = 1'-0" E.H.D.T. WASTE & VENT PLAN UP 18x36 5 TIER 18x60 5 TIER 18 x 2 4 5 T I E R A.03 18x54 5 TIER 18 x 3 6 5 T I E R 18 x 3 6 5 T I E R GENERAL NOTES: #KEYED PLAN NOTES: 1.INSTALL 1"CW SUB METER. CONFIRM MAKE/MODEL & ALL REQUIREMENTS WITH LANDLORD. FIELD VERIFY ALL CONDITIONS AND LOCATIONS PRIOR TO START OF THIS WORK. 2.P.O.C. TO EXISTING 2-1/2" CW LINE WITH NEW PIPING. FIELD VERIFY ALL EXISTING CONDITIONS SIZE AND LOCATIONS PRIOR TO START OF THIS WORK. 3.P.O.C. TO EXISTING 4" GAS LINE WITH NEW PIPING. FIELD VERIFY ALL EXISTING CONDITIONS SIZE AND LOCATIONS PRIOR TO START OF THIS WORK. 4.AUTOMATIC GAS SHUT OFF VALVE INTERLOCK WITH HOOD FIRE SUPPRESSION SYSTEM, WITH ACCESS PANEL. 5.INSTALL ICE MACHINE WITH ASSE 1022 LISTED BACKFLOW PREVENTER. 6.INSTALL MOP SINK W/ VACUUM BREAKER. 7.PROVIDE 1/2" TRAP PRIMER FOR FLOOR DRAIN. 8.INSTALL WATER HEATER WITH NEW PIPING. FIELD VERIFY LOCATION AND SIZE BEFORE START OF WORK. SEE PLUMBING SCHEDULE AND PLUMBING DETAILS ON P000 AND P001, RESPECTIVELY. 1.IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION, CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATION REFLECTING ACTUAL CONDITIONS. 2.ALL PLUMBING FIXTURES AND CONNECTIONS ARE NEW UNLESS NOTED AS EXISTING. WATER & GAS PLAN WMPRV 1 1/2"CW UP TO CEILING FOR MAU (1 FU) URL WC LAV LAV MOP WH ABOVE MOP PREP 3-COMP ICE MACHINE 1-1/4"CW (TOT. 49 FU) SUB WATER METER HS-1 4 1/2"HW/CW FOR PREP (3 FU) 3/4"HW/CW NPT FOR WH TYP. 1/2"HW/CW FOR HS (2 FU)1-1/4"HW (TOT. 22 FU) TYP. 1/2"HW/CW FOR LAV (1 FU) TYP. 3/4"CW FOR WC (2.5 FU) FD WC 7 6 8 1/2"HW/CW FOR MOP (3 FU) 1"CW FOR URL (20 FU) 3/4"HW UNDER COUNTER (6 FU) 1/2"CW UNDER COUNTER (6 FU) 1/2"HW UNDER COUNTER (2 FU) 1/2"CW UNDER COUNTER (2 FU) 1/2"CW FOR ICE (1 FU) 3/4"HW (8 FU) HS-2 BAR SINK 5 FRYER WOK GRIDDLE RANGE 1-1/4"G (120 CFH) 1-1/2"G (210 CFH) 1"G (90 CFH) 1"G (95 CFH) 2"G (395 CFH) AUTOMATIC GSOV 2"G (515 CFH) 1/2"CW (2 FU) 3/4"CW (3.5 FU) 1-1/4"CW (42 FU) 1/2"CW (5 FU) 1/2"CW (6 FU) 3/4"CW (10 FU) 1-1/4"CW (33 FU) 3/4"HW (5 FU) TYP. 1/2"HW/CW FOR 3-COMP (2 FU PER FAUCET) 3 1"CW (30 FU) 1"HW (11 FU) 2 1/2"HW (2 FU) 1"HW (11 FU) HS-1 DUMP SINK 3/4"HW UNDER COUNTER (4 FU) 1/2"CW UNDER COUNTER (4 FU) 7FD 1/2"CW RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 12/2/2025 12:13:09 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 PL A N C H E C K R E V . 1 2 / 0 2 / 2 0 2 5 P200 1/4" = 1'-0" E.H.D.T. WATER & GAS PLAN PLUMBING ISOMETRIC DIAGRAM FS FS FS FS FS FD FS FS FD WM FD FD WCO FCO WCO 2"V HS-1 (E) 4"GW 2"V PREP WC LAV LAV WC2"V 3"V 3"V 2"V 2"V 2"V BAR SINK DUMP SINK HS-2 ICE MACHINE HS-1 4"W; MINIMUM 2% SLOPE TYP. 4"W FOR WC TYP. 2"W FOR LAV 3-COMP(E) 4"GW (E) 4"GW MOP URL 2"V 2"W 4"W; MINIMUM 2% SLOPE 1-1/2"G (210 CFH) 1"G (90 CFH) 1"G (95 CFH) 1-1/4"G (120 CFH) 2"G (395 CFH) AUTOMATIC GSOV 2"G (515 CFH) 2"G (515 CFH) RANGE GRIDDLE WOKFRYER 1/2"CW HS-1 PREP 3-COMP WC WC LAV LAV TYP. 3/4"CW FOR WC (2.5 FU) TYP. 1/2"HW/CW FOR LAV (1 FU) SUB WATER METER PRV 1-1/4"CW (TOT. 49 FU) 3/4"CW (3.5 FU) MOP 1/2"HW/CW FOR MOP (3 FU) 1"CW FOR URL (20 FU) HS-1 ICE MACHINE 1/2"CW (2 FU) HS-2 BAR SINK DUMP SINK 1/2"HW UNDER COUNTER (2 FU) 1/2"CW UNDER COUNTER (2 FU) 3/4"HW UNDER COUNTER (4 FU) 1/2"CW UNDER COUNTER (4 FU) 1/2"CW UP TO CEILING FOR MAU (1 FU) 3/4"HW UNDER COUNTER (6 FU) 1/2"CW UNDER COUNTER (6 FU) 1/2"CW FOR ICE (1 FU) 1/2"CW (6 FU) 3/4"HW (8 FU) 1"CW (30 FU) 1"HW (11 FU) 1-1/4"HW (TOT. 22 FU) TYP. 1/2"HW/CW FOR 3-COMP (2 FU PER FAUCET)1/2"HW/CW FOR PREP (3 FU) TYP. 1/2"HW/CW FOR HS (2 FU) 1/2"CW (5 FU) 3/4"HW (5 FU) 1/2"HW (2 FU) 1-1/4"CW (42 FU) TRAP PRIMER TRAP PRIMER URL WASTE & VENT WATER GAS 2"W TYP. 2"W FOR FS 3" TRAP ARM 2"GW 2"GW 4"W; MINIMUM 2% SLOPE 3"V 3"V RE V I S I O N SHEET TITLE: DATE: SCALE: AR T E R E S T A U R A N T 03/03/2025 PLOT DATE: 12/2/2025 12:13:10 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 10 9 E 4 T H S T . , SA N T A A N A , C A 9 2 7 0 1 DRAWN: CHECKED: PL A N C H E C K R E V . 0 5 / 1 2 / 2 0 2 5 FI E L D C H A N G E 0 9 / 0 5 / 2 0 2 5 PL A N C H E C K R E V . 0 9 / 2 9 / 2 0 2 5 PL A N C H E C K R E V . 1 2 / 0 2 / 2 0 2 5 P300 1/4" = 1'-0" E.H.D.T. PLUMBING ISOMETRIC DIAGRAM EQUIPMENT PLAN, INTERIOR ELEVATIONS & SCHEDULES 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C EQUIPMENT SCHEDULE EQUIPMENT CATEGORY QTY MANUFACTURER MODEL NO.REMARK 1 (N) POS SYSTEM 1 TOAST ------ 2 (N) UNDERBAR ICE BIN 3 REGENCY 600IB1824CP 24"L x 18 1 2"W x 33"H 3 (N) HAND SINK 3 REGENCY 600HS12SP 12" X 16" WALL MOUNTED HAND SINK WITH GOOSENECK FAUCET AND 6" HIGH SPLASH GUARD ON BOTH SIDES EXTEND TO THE EDGE OF HAND SINK, WALL MOUNTED SINGLE-USE SOAP AND PAPER 4 (N) 3 BOWL UNDERBAR SINK 1 REGENCY 60B31014213K 60"L x 18 3 4"W x 33"H W/ 6" HIGH SPLASH GUARD ON BOTH SIDES EXTENDING TO THE EDGE OF THE SINK 5 (N) ICE MACHINE 1 AVANTCO 194KMCH322BA 22" W x 32 11 16 " D x 67 11 16 " H 6 (N) EMPLOYEE LOCKER 2 REGENCY 6 TIER LOCKER 12" W x 78" H, OPERABLE PARTS SHALL BE FROM 15" TO 48" A.F.F., STANDING ON MIN. 6" HIGH ROUND METAL LEGS. NO L-SHAPED LEGS ARE ALLOWED 7 (N) S.S. 5 TIERS SHELVING 7 STEELTON -SIZE VARIES 8 (N) UNDERBAR DUMP SINK 1 REGENCY 600B11014 --- 9 (N) FOOD PREPARATION TABLES 1 BEVERAGE-AIR DP60HC 60" W x 37" D x 53 1 4" H 10 (N) DOUBLE DOOR REACH-IN FREEZER 1 AVANTCO A-49R-HC 54" W x 32 3 16" D x 82 1 2" H 11 (N) WATER HEATER ABOVE 1 AO SMITH -SEE MECHANICAL DWGS. 12 (N) MOP SINK 1 REGENCY 600SM162012 25"L X 21"W X 16"H 13 (N) MOP RACK W/ CHEMICAL SHELF 1 REGENCY 600WSU824 24" STAINLESS STEEL MOP/BROOM RACK W/ CHEMICAL SHELF 14 (N) 3 COMPARTMENT SINK 1 REGENCY 600S318242X 94" L x 29 13 16" W x 43 3 4 " H, W/ 2 DRAINBOARDS - 18" X 18" X 14" BOWLS. MIN. 8" INTEGRAL END RETURN SHALL BE EXTENDED UP AND SEALED TO THE WALL 15 (N) PREP SINK W/ DRAINBOARD 1 STEELTON 522CS11818RK STEELTON 38 3/4" 18-GAUGE STAINLESS STEEL ONE COMPARTMENT COMMERCIAL SINK WITH RIGHT DRAINBOARD - 18" X 18" X 12" BOWL, 6" HIGH PLASHGUARD ON THE LEFT 16 (N) SINGLE DOOR REACH-IN FREEZER 1 AVANTCO A-19F-HC 29" W x 25 1 2 " D x 82 1 2" H 17 (N) STAINLESS STEEL FRYER 1 AVANTCO 177FF50N 15 1 2 " W x 30 1 4" D x 47 1 8 " H 18 (N) NATURAL GAS WOK RANGE 1 CPG 351WOKR13N 17" W x 24" D x 34" H 19 (N) NATURAL GAS 36" RANGE W/ 36" GRIDDLE 1 CPG 351S36G36N 36" W x 32 5 8 " D x 60 3 8 " H 20 (N) NATURAL GAS 36" RANGE W/ STANDARD OVEN 1 CPG 351S36N 36" W x 32 5 8 " D x 60 3 8 " H 21 (N) TYPE I HOOD 1 CAPTIVEAIRE 5424ND-2-PSP-F 12' W x 4'6" D 22 (N) (LOW VELOCITY) AIR CURTAIN 1 MARS 36-NCH AUTOMATIC, UNHEATED RECOMMENDED FOR CUSTOMER ENTRANCE DOORS 23 (N) WOOD STAGE PLATFORM FOR SINGER 1 ------6" ABOVE FINISH FLOOR 24 (N) DECORATIVE CABINET 1 ------CUSTOM MADE MILLWORK 25 (N) 3 TIER WALL MOUNTED WINE RACK 1 --------- 26 (N) UNDERBAR COOLER 1 TRUE TBB-4G-HC-LD --- 27 (N) COFFEE MAKER 1 AVANTCO C10 --- EQUIPMENT NOTE: ALL NEW AND REPLACEMENT FOOD RELATED OR UTENSIL RELATED EQUIPMENT SHALL BE CERTIFIED OR CLASSIFIED FOR SANITATION BY AN AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ACCREDITED CERTIFICATION PROGRAM. EXAMPLE OF THESE ACCREDITED PROGRAMS INCLUDE NSF, UL, INTERTEKETL, CSA ETC. 1EQUIPMENT PLAN 1/4"=1'-0" N EQ-1.0 7INTERIOR ELEVATION 1/4"=1'-0" 2INTERIOR ELEVATION 1/4"=1'-0"3INTERIOR ELEVATION 1/4"=1'-0" 6INTERIOR ELEVATION 1/4"=1'-0" 4INTERIOR ELEVATION 1/4"=1'-0" 5INTERIOR ELEVATION 1/4"=1'-0" UP 18x36 5 TIER 18x60 5 TIER 18 x 2 4 5 T I E R A.03 18x54 5 TIER 18 x 3 6 5 T I E R 18 x 3 6 5 T I E R 1 14 12 11 13 EQ-1 3 19 1820 317 16 1432 10 7 79 1 6" 10 ' - 0 " EQ-1 2 22 2' - 1 0 " 3' - 6 " 2 3 4 2 5 6 7 7 7 7 7 9 10 15 3 16 17 18 19 20 21 EQ-1 4EQ-1 5 EQ-1 6 EQ-1 7 7' - 6 " 7 7 21 9 11 13 12 EXIT 6" 10 ' - 0 " 4'-0" 23 24 7 3 7 2'-6" 2' - 6 " 2'-6" 10 ' - 0 " 25 2 26 8 28 27 UP 18x36 5 TIER 18x60 5 TIER 18 x 2 4 5 T I E R A.03 18x54 5 TIER 18 x 3 6 5 T I E R 18 x 3 6 5 T I E R 1 14 12 11 13 EQ-1 3 EQ-1 2 22 2 3 4 2 5 6 7 7 7 7 7 9 10 15 3 16 17 18 19 20 21 EQ-1 4EQ-1 5 EQ-1 6 EQ-1 7 4'-0" 23 24 7 3 2'-6" 2' - 6 " 2'-6" 25 2 26 8 27 1 2' - 1 0 " 3' - 6 " 7' - 6 " 10 ' - 0 " 10 7 797191820317167721 6" 10 ' - 0 " 6" 10 ' - 0 " EXIT 9 11 13 12 143228 EQUIPMENT PLAN, INTERIOR ELEVATIONS & SCHEDULES 10 9 E 4 T H S T . , S A N T A A N A , C A 9 2 70 1 AR T E R E S T A U R A N T SHEET NO.: RE V I S I O N SHEET TITLE: DATE: SCALE: 02/21/2025 5- 2 8 - 2 5 1S T H E A L T H P C CD I Ci r c a D o m i n i I n t e r n a t i o n a l , L L C En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . , S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e . ( 9 4 9 ) 5 3 3 - 4 1 1 7 9- 4 - 2 5 2N D H E A L T H P C 10 - 7 - 2 5 1S T B U I L D I N G P C 10 - 7 - 2 5 3R D H E A L T H P C EQUIPMENT SCHEDULE EQUIPMENT CATEGORY QTY MANUFACTURER MODEL NO.REMARK 1 (N) POS SYSTEM 1 TOAST ------ 2 (N) UNDERBAR ICE BIN 3 REGENCY 600IB1824CP 24"L x 18 1 2"W x 33"H 3 (N) HAND SINK 3 REGENCY 600HS12SP 12" X 16" WALL MOUNTED HAND SINK WITH GOOSENECK FAUCET AND 6" HIGH SPLASH GUARD ON BOTH SIDES EXTEND TO THE EDGE OF HAND SINK, WALL MOUNTED SINGLE-USE SOAP AND PAPER 4 (N) 3 BOWL UNDERBAR SINK 1 REGENCY 60B31014213K 60"L x 18 3 4"W x 33"H W/ 6" HIGH SPLASH GUARD ON BOTH SIDES EXTENDING TO THE EDGE OF THE SINK 5 (N) ICE MACHINE 1 AVANTCO 194KMCH322BA 22" W x 32 11 16 " D x 67 11 16 " H 6 (N) EMPLOYEE LOCKER 2 REGENCY 6 TIER LOCKER 12" W x 78" H, OPERABLE PARTS SHALL BE FROM 15" TO 48" A.F.F., STANDING ON MIN. 6" HIGH ROUND METAL LEGS. NO L-SHAPED LEGS ARE ALLOWED 7 (N) S.S. 5 TIERS SHELVING 7 STEELTON -SIZE VARIES 8 (N) UNDERBAR DUMP SINK 1 REGENCY 600B11014 --- 9 (N) FOOD PREPARATION TABLES 1 BEVERAGE-AIR DP60HC 60" W x 37" D x 53 1 4" H 10 (N) DOUBLE DOOR REACH-IN FREEZER 1 AVANTCO A-49R-HC 54" W x 32 3 16" D x 82 1 2" H 11 (N) WATER HEATER ABOVE 1 AO SMITH -SEE MECHANICAL DWGS. 12 (N) MOP SINK 1 REGENCY 600SM162012 25"L X 21"W X 16"H 13 (N) MOP RACK W/ CHEMICAL SHELF 1 REGENCY 600WSU824 24" STAINLESS STEEL MOP/BROOM RACK W/ CHEMICAL SHELF 14 (N) 3 COMPARTMENT SINK 1 REGENCY 600S318242X 94" L x 29 13 16" W x 43 3 4 " H, W/ 2 DRAINBOARDS - 18" X 18" X 14" BOWLS. MIN. 8" INTEGRAL END RETURN SHALL BE EXTENDED UP AND SEALED TO THE WALL 15 (N) PREP SINK W/ DRAINBOARD 1 STEELTON 522CS11818RK STEELTON 38 3/4" 18-GAUGE STAINLESS STEEL ONE COMPARTMENT COMMERCIAL SINK WITH RIGHT DRAINBOARD - 18" X 18" X 12" BOWL, 6" HIGH PLASHGUARD ON THE LEFT 16 (N) SINGLE DOOR REACH-IN FREEZER 1 AVANTCO A-19F-HC 29" W x 25 1 2" D x 82 1 2" H 17 (N) STAINLESS STEEL FRYER 1 AVANTCO 177FF50N 15 1 2 " W x 30 1 4" D x 47 1 8 " H 18 (N) NATURAL GAS WOK RANGE 1 CPG 351WOKR13N 17" W x 24" D x 34" H 19 (N) NATURAL GAS 36" RANGE W/ 36" GRIDDLE 1 CPG 351S36G36N 36" W x 32 5 8 " D x 60 3 8 " H 20 (N) NATURAL GAS 36" RANGE W/ STANDARD OVEN 1 CPG 351S36N 36" W x 32 5 8 " D x 60 3 8 " H 21 (N) TYPE I HOOD 1 CAPTIVEAIRE 5424ND-2-PSP-F 12' W x 4'6" D 22 (N) (LOW VELOCITY) AIR CURTAIN 1 MARS 36-NCH AUTOMATIC, UNHEATED RECOMMENDED FOR CUSTOMER ENTRANCE DOORS 23 (N) WOOD STAGE PLATFORM FOR SINGER 1 ------6" ABOVE FINISH FLOOR 24 (N) DECORATIVE CABINET 1 ------CUSTOM MADE MILLWORK 25 (N) 3 TIER WALL MOUNTED WINE RACK 1 --------- 26 (N) UNDERBAR COOLER 1 TRUE TBB-4G-HC-LD --- 27 (N) COFFEE MAKER 1 AVANTCO C10 --- EQUIPMENT NOTE: ALL NEW AND REPLACEMENT FOOD RELATED OR UTENSIL RELATED EQUIPMENT SHALL BE CERTIFIED OR CLASSIFIED FOR SANITATION BY AN AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ACCREDITED CERTIFICATION PROGRAM. EXAMPLE OF THESE ACCREDITED PROGRAMS INCLUDE NSF, UL, INTERTEKETL, CSA ETC. 1EQUIPMENT PLAN 1/4"=1'-0" N EQ-1.0 7INTERIOR ELEVATION 1/4"=1'-0" 2INTERIOR ELEVATION 1/4"=1'-0"3INTERIOR ELEVATION 1/4"=1'-0" 6INTERIOR ELEVATION 1/4"=1'-0" 4INTERIOR ELEVATION 1/4"=1'-0" 5INTERIOR ELEVATION 1/4"=1'-0" 4 4 4 4 4 4 4 4 4 4 CITY OF SANTA ANA Planning and Building Agenc Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org A. PURPOSE OF THIS DOCUMENTATION: (check one) DISABLED ACCES DOCUMENTA ❑ Finding of unreasonable hardship for projects UNDER the valuation threshold' ❑ Finding of unreasonable hardship for projects OVER the valuation threshold` X Certification of Full Compliance with the 2022 California Building Code coMAppawed PUTPIIEWAIT ISSUANCE DateACC-01 CBC 2022 Valuation threshold as defined in the 2022 California Building Code, Section 11 B-202.4 (Exception #8) and Section 202 is $203,611.00 (as of January 2025) B. PROJECT INFORMATION TO BE COMPLETED BY PETITIONER: Project Address: E- 14� cp� qa-1p Permit Number: Pro ect Description: Floor Number: o Cc— 6eblau-aLiJ Business Name //Owner: i(4e- Business Phone Number. Legal Property Owner: one Number: ('-3'nq � - q 3 �, Total Construction Cost roject Valuation: Cost of Providing Complete Disabled Access: $ $ ' 1. The cost of all construction contemplated in the determination of the valuation of improvement threshold based on the valuation of site and building improvements for the last three-year period. E 20% of Total Construction Cost or Project Valuation: $ 3. The actual amount to be spent to provide disabled access: $ 4. Describe the impact of the proposed improvements on financial feasibility of the project. 6 5. Describe the proposed improvements `elated to accessibility upgrades on this pro a � �5 14 Pace 1 of 2 CITY OF SANTA ANA Planning and Building Ager features and equivalent facilities that WILL be brought into compliance jr(ij�Uie,.oved 6. Identity the accessibility latest edition of Title 24 as a part of this project and an estimate of the cost of each ite (FOR PERMIT ISSUANCE may be required) Accessible Features to be Made Accessible Cost f Improvement Master ID: a. Entrance: ❑ Door ❑ Landing ❑ Stairway/Steps ❑ Ramp $ b. Path of Travel: ❑ Path of travel from accessible parking to the building entrance $ and area of remodel Path of travel to sanitary facilities / public phone / drinking $ fountain ❑ Path of travel from the public way to the building entrance $ C. Sanitary facilities ( Floor no. ) $ $ d. Public phone(s) e. Drinking fountain(s) $ f. Parking $ g. Signage & Alarms $ i. Other: $ Total: $ 7. Identify the accessibility features that WILL NOT comply if a request for unreasonable hardship is granted. Provide an estimated cost of compliance for each item: (Documentation may be required) Accessible Features Not to be Improved Cost of Improvement a. $ b. $ C. $ Total: $ 8. Petitioner must be the legal property owner or his/her legal representative: I certify that the above noted information is true and correct. ❑ Legal Property Owner ❑ Architect/Engineer ❑ Contractor] Other: Print Name: Phone No. rV Address: Signature: FOR AGENCY USE ONLY Approved by: Date: Rev: 03/18/2025 Page 2 of 2 GREASE INTERCEPTOR MEMORANDUM To: Kay Ayazi – Applicant Date: May 5, 2025 Yolanda G Cervantes – Associate Engineer From: PWA, Water Resources Location: 109 E 4TH ST – ARTE RESTAURANT The above referenced food service establishment (FSE) must comply with the Fats, Oils, and Grease (FOG) Control Program Rules and Regulations as identified in Ordinance NS-2921 and as follows: A Gravity Grease Interceptor (GGI) is required at this FSE ☐ This FSE shall install a Gravity Grease Interceptor (GGI). ☒ This FSE shall maintain the existing Gravity Grease Interceptor (GGI). This FSE qualifies for at least one of the following condition(s): This is a new FSE, or; This is an existing FSE undergoing remodeling, or; This is an existing FSE involving a change (of operation, ownership, and/or name) that is likely to continue discharging a high level of FOG or has the potential to increase the amount of FOG discharged to the sewer system. C/c: Water Resources Division Planning & Building Agency OC Health Care Agency Public Works Agency (Development) EEC Environmental Applicant ORANGE COUNTY 14'1 RE AUT110RIT Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL proje and RESIDENTIAL TRACT developments CITY OF SANTA ANA Planning and Building Agency FOR I C s INSTRUCTIONS: iviasier iu: • Fill in the project/business address and provide a brief description of the scope of work and type of busing gyration that will take place. • Answer questions 1 through 10. read and initial items 11 and 12, then complete and sign the certification ection. • If you answer - "YES" to any part of questions 1 through 10, submit the type of plan indicated in Italics to DGFA. • In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. • Visit www.ocfa.ora for submittal information and locations. If you need assistance In filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. 1 Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. O Property is adjacent to a wildland area or non -irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Platt may also be required (PR120, PR124) 3. O Located in or < 100' from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300' from an oil/gas seep, or < 1000' from a landfill? Methane Work Plan. (PR170) 4. O Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Offtciao? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. O Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. ( Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; O CA industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 Ib. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) g. O j� Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chern Class & floor plan (full architectural plan if If occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. O Storage or merchandizing areas In excess of 500 sq. ft. where Items are located higher than 12' (6' for high -hazard commodities, plastic, rubber, foam, etc.)? Nigh -piled Storage Plan (PR330) 10.VQCooking under a Type I commercial hood; Installation or modification of a fire extinguishing system located in a commercial cooking hood? Nnod & Duct Extinguishing Svslern, not.just the hood mechanical plan. (PR335) Initial each of the following two items Indicating that you have read and understand the statement: 11. �'Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine spdnklerlalarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed A contractor to determine if modification Is needed; If so, contractor shall submit plans prior to making modifications. 12.Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the b Is e: Print Name <1 / , f a J A -7_ Signature Phone Number t Q1 q t , G t.t 4 - /JR + --.4 I Date Building Department: If you have verified that all of the questions have been answered accurately as "NO and the project dues not otherwise require OCFA review of sprinkler or alarm plans', then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the f mn along with the 10-08 14 I 1 appropriate plans and fees for OCFA review. CITY OF SANTA ANA Planning and Building Agency 1R6 ORANGE COUNTY FIRE AUTHORI Approved i Plan Referral Form POR PERMIT ISSUANCE Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all "No Master ID: Date: City / County Official Requesting Review: City / County Reference #: City / County: Contact Name: Title: Date: E-Mail: Phone #: ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County: OCFA COMMENTS: OCFA Authorization ❑ No further action required on this specific plan type, based on information provided on: ❑ Project to be taken in for OCFA Review. Other: Name: Contact #: odated: 06/02/2020. Date: