Loading...
HomeMy WebLinkAbout3606 S Van Ness Ave - PlanTo: City of Santa Ana Building Department Subject: Authoriza+on to Apply for Solar Permit for Project at 3606 S Van Ness Ave, Santa Ana, CA 92707 This leDer serves as formal authoriza+on from VIEKO INNOBUILD INC to appoint the individuals named below as our authorized agents for the purpose of submiIng, applying for, and obtaining the necessary Solar PV Permit from the City of Santa Ana for the project located at 3606 S VAN NESS AVE, SANTA ANA, CA 92707. Project & Contractor Details • Project Address: 3606 S VAN NESS AVE, SANTA ANA, CA 92707 • Job DescripNon: 6.450 kWDC Solar PV roof mount installa+on • Contractor Name: VIEKO INNOBUILD INC • State Contractor's License #: 1138900 • Santa Ana Business License #: 397762 • Contractor Address: 17091 DAIMLER STREET Authorized Agents The following individuals are authorized to act on behalf of VIEKO INNOBUILD INC concerning this permit applica+on: • Name: Joshua Nolasco o Email: joshua@aptusenergy.com • Name: Henry Wang This authoriza+on includes, but is not limited to, the following ac+ons: 1. SubmiIng the Solar Permit Applica+on Worksheet. 2. Interac+ng with City staff regarding plan check comments and revisions. 3. Paying all required permit fees. 4. Accep+ng the issued permit. We confirm that all informa+on provided in the applica+on is true and accurate. Authorized Signature (Contractor): Printed Name & Title: ___________________ To Whom It May Concern: I, YE ZHU, as the owner of the property located at the project address listed below, hereby authorize the contractor, VIEKO INNOBUILD INC, to proceed with the installation of the Photovoltaic Roof Mount System as outlined in the project plans. Project Details • Property Owner: YE ZHU • Project Address: 3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA • System Description: Photovoltaic Roof Mount System o System Size: 6.450 kWDC, 5.000 KWAC • Authorities Having Jurisdiction (AHJ): SANTA ANA CITY (Building & Zoning) • Utility: SOUTHERN CALIFORNIA EDISON (SCE) Authorization Statement This letter serves as formal consent for VIEKO INNOBUILD INC to access the property and perform all necessary work, including obtaining required permits, completing construction, and coordinating inspections, for the installation of the new photovoltaic system. The contractor is responsible for ensuring all work adheres to the Governing Codes, including the 2022 California Electric Code, 2022 California Building Code, and all other applicable codes listed in the design criteria. Homeowner Signature: Printed Name: YE ZHU COVER SHEET REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-0 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 3 2 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 4 1 0 1 4 1 3 6 AH J : S A N T A A N A C I T Y APTUS ENERGY PHOTOVOLTAIC ROOF MOUNT SYSTEM 3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA GENERAL: 1. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PHOTOVOLTAIC SYSTEM. 2. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION 3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO INITIATING CONSTRUCTION. 4. CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. 5. ALL EQUIPMENT AND ASSOCIATED CONNECTIONS, ETC, AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONNEL. 6. THE CONTRACTOR OR OWNER MUST PROVIDE ROOF ACCESS (LADDER TO ROOF) FOR ALL THE REQUIRED INSPECTIONS. LADDERS MUST BE OSHA APPROVED, MINIMUM TYPE I WITH A 250LB. RATING, IN GOOD CONDITION AND DESIGNED FOR ITS INTENDED USE. 7. CONTRACTOR SHALL VERIFY THAT THE ROOF STRUCTURE WILL WITHSTAND THE ADDITIONAL LOADS. 8. LAG SCREWS SHALL PENETRATE A MINIMUM 2" INTO SOLID SAWN STRUCTURAL MEMBERS AND SHALL NOT EXCEED MANUFACTURER RECOMMENDATIONS FOR FASTENERS INTO ENGINEERED STRUCTURAL MEMBERS. 9. AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT PLACE THE GROUND LADDER OVER OPENINGS SUCH AS WINDOWS OR DOORS ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION AND IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. 10. WHERE DC CONDUCTORS ARE RUN INSIDE BUILDING, THEY SHALL BE CONTAINED IN A METAL RACEWAY; THEY SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE COVERED BY THE PV MODULES AND EQUIPMENT. 11. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY SOLAR MODULES- - NO BUILDING, PLUMBING OR MECHANICAL VENTS TO BE COVERED, CONSTRUCTED OR ROUTED AROUND SOLAR MODULES. 12. ALL FIELD -INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS. 15 MODULES-ROOF MOUNTED - 6.450 kWDC, 5.000 kWAC 2 VICINITY MAP SCALE: NTSPV-0 1 AERIAL PHOTO SCALE: NTSPV-0 DESIGN CRITERIA: PV-0 COVER SHEET PV-1 SITE PLAN PV-2 ATTACHMENT PLAN PV-3 FLOOR PLAN PV-4 STANDOFF DETAILS PV-5 SINGLE LINE DIAGRAM & CALCULATION PV-6 THREE LINE DIAGRAM & CALCULATION PV-7 STRING MAP PV-8 PLACARDS & WARNING LABELS PV-9 ELEVATION DETAILS PV-10 MAIN PANEL PHOTO PV-11 MODULES DATASHEET PV-12 INVERTER DATASHEET PV-13 BATTERY DATASHEET PV-14 OPTIMIZERS DATASHEET PV-15 ATTACHMENT DATASHEET PV-16 RAIL DATASHEET SHEET INDEX CONSTRUCTION: SFR ZONING: RESIDENTIAL GROUND SNOW LOAD : 0 PSF WIND SPEED : 95 MPH WIND EXPOSURE: B RISK CATEGORY: II GOVERNING CODES: 2022 CALIFORNIA ELECTRIC CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA MECHANICAL CODE OWNER: NAME: YE ZHU ADDRESS: 3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA AUTHORITIES HAVING JURISDICTION: BUILDING: SANTA ANA CITY ZONING: SANTA ANA CITY UTILITY : SOUTHERN CALIFORNIA EDISON (SCE) SYSTEM SUMMARY: (N)15 - SUNKET SKT430M10-108D5 (430W) SOLAR MODULES (N)01 - AMENSOLAR N3H-X5US HYBRID INVERTER (N)15 - TS4-A-O OPTIMIZERS (N) 1 - JUNCTION BOX (N) 1 - 100A FUSED AC DISCONNECT (N) 1 - SUNKET-ESS LFP 16kWh BATTERY (N) 100A BACKUP LOAD PANEL ELECTRICAL: 1. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25°C AND MAXIMUM VOLTAGE AT 600V; WIRE SHALL BE WET RATED AT 90°C. 2. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE 2 OR PV-TYPE WIRE. 3. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR-CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS. 4. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS. 5. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. 6. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. 7. REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 8. FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH A GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURED AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS. 9. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION. 10. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER GEC/GEC PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 11. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER GEC VIA WEEB LUG, ILSCO GBL-4DBT LAY-IN LUG, OR EQUIVALENT LISTED LUG. 12. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT. 13. RACKING AND BONDING SYSTEM TO BE UL2703 RATED. 14. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AS BUS BARS WITHIN LISTED EQUIPMENT. 15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE AND LOAD". 16. WHEN APPLYING THE 120% RULE, THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. 17. THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED. Signed-12/08/2025 EXP. 09/30/2026 18" FIRE SETBACK 36 " F I R E S E T B A C K 18" FIRE SETBACK 18'-7" 2' - 8 " 13'-4"1' - 3 " 79'-6" 51 ' - 1 0 " 79'-6" 51 ' - 1 0 " MS P IN V BL P BA T T UM AC D MS P IN V BL P BA T T UM AC D REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-1 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 3 2 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 4 1 0 1 4 1 3 6 AH J : S A N T A A N A C I T Y APTUS ENERGY SITE PLAN 67.79" 44 . 6 4 " PHOTOVOLTAIC MODULES SUNKET SKT430M10-108D5 (430W) 5.000 kW AC 6.450 kW DC ARRAY (15)SUNKET SKT430M10-108D5 (430W) SOLAR MODULES LEGEND JUNCTION BOXJB FENCE PROPERTY LINE CONDUIT RUN ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ROOF MOUNTED PHOTOVOLTAIC ARRAY 15 SUNKET SKT430M10-108D5 (430W) SOLAR MODULES=6450 DC WATTS NOTE: AC CONDUIT RAN THROUGH THE ATTIC IN INTERIOR OF HOME 3/4" EMT S V A N N E S S A V E DR I V E W A Y INVERTERINV (N)AMENSOLAR N3H-X5US HYBRID INVERTER ARRAY AREA & ROOF AREA CALC'S AREA OF NEW ARRAY (Sq. Ft.) AREA OF ROOF(PLAN VIEW) (Sq. Ft.) TOTAL ROOF AREA COVERED BY ARRAY % 315.22 2386 13.21% 13.21%ROOF AREA (ARRAY >33% OF ROOF AREA) ACD AC DISCONNECT (N)FUSED UTILITY AC DISCONNECT (N) SUNKET-ESS LFP 16kWh BATTERY BATTERYBATT NOTE: ROOMS AND AREAS WITHIN DWELLING UNITS, BASEMENTS AND ATTACHED GARAGES IN WHICH ESS ARE INSTALLED SHALL BE PROTECTED BY SMOKE ALARMS IN ACCORDANCE WITH SECTION R314. A HEAT DETECTOR, LISTED AND INTERCONNECTED TO THE SMOKE ALARMS, SHALL BE INSTALLED IN LOCATIONS WITHIN DWELLING UNITS AND ATTACHED GARAGES WHERE SMOKE ALARMS CANNOT BE INSTALLED BASED ON THEIR LISTING UM MSP MAIN SERVICE PANEL UTILITY METER (E)MAIN SERVICE PANEL (E) UTILITY METER (N)BACKUP LOAD PANEL BLP BACKUP LOAD PANEL Signed-12/08/2025 EXP. 09/30/2026 REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-13 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY BATTERY DATASHEETESS–INVERTER COMPATIBILITY NOTE : THE AMENSOLAR N3H-X5US HYBRID INVERTER IS TECHNICALLY COMPATIBLE WITH THE SUNKET ESS 16 KWH LIFEPO₄ BATTERY. THE INVERTER SUPPORTS 48 V LITHIUM BATTERIES WITHIN A 40–60 V DC OPERATING RANGE AND COMMUNICATES VIA CAN/RS-485, WHICH MATCHES THE SUNKET ESS BATTERY’S VOLTAGE RANGE AND BMS COMMUNICATION INTERFACES. CHARGE/DISCHARGE CURRENT RATINGS OF BOTH DEVICES ARE WITHIN ALLOWABLE LIMITS. SYSTEM INTEGRATION MEETS MANUFACTURER-PUBLISHED ELECTRICAL AND COMMUNICATION SPECIFICATIONS. REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY BATTERY MOUTING PLAN SUNKET-ESS LFP 16kWh BATTERY FLOOR-MOUNTED SUNKET-ESS LFP 16 KWH BATTERY SHALL BE SECURED AT THE TOP USING MANUFACTURER-SUPPLIED L-BRACKETS. BRACKETS SHALL BE ANCHORED TO A STRUCTURAL WALL WITH (2) M6 EXPANSION ANCHORS INTO CONCRETE/MASONRY OR (2) 1/4″ LAG BOLTS INTO WOOD STUDS, MINIMUM 70 MM EMBEDMENT. ATTACHMENT SERVES AS ANTI-TIP RESTRAINT ONLY; THE FLOOR SUPPORTS THE FULL BATTERY WEIGHT. ANCHORS SHALL BE INSTALLED INTO LOAD-BEARING CONSTRUCTION ONLY (NO DRYWALL). 90 0 m m 530mm 300mm 300mm CLEARANCES: MAINTAIN A MINIMUM 300MM (12") CLEARANCE ON ALL SIDES AND ABOVE THE UNIT FOR VENTILATION AND EMERGENCY ACCESS. ENSURE THE UNIT IS MOUNTED ON A NON-FLAMMABLE SUBSTRATE TO MEET FIRE SAFETY REQUIREMENTS. 70 m m 70 m m BASE ANCHORING: SECURE THE BATTERY BASE TO THE FLOOR USING (4) M6 EXPANSION BOLTS DRILLED TO A MINIMUM DEPTH OF 70MM. BOLTS MUST BE TORQUED TO 6 NM TO PREVENT LATERAL DISPLACEMENT. SUNKET-ESS LFP 16kWh BATTERY WEIGHT - 120KG DIMENSIONS (WIDTH X HEIGHT X DEPTH) -530 X 900 X 245mm THE UNIT SHALL BE INSTALLED ON A LEVEL, NON-COMBUSTIBLE CONCRETE SURFACE. THE STATIC FLOOR LOAD IS APPROXIMATELY 265 LBS; VERIFY THE SLAB IS CAPABLE OF SUPPORTING THIS CONCENTRATED LOAD PER LOCAL BUILDING CODES. NOTE: BATTERY IS FLOOR-MOUNTED WITH WEIGHT SUPPORTED BY CONCRETE SLAB. TOP WALL ATTACHMENT PROVIDED AS AN ANTI-TIP RESTRAINT ONLY. L-BRACKETS ANCHORED TO BUILDING STRUCTURE USING (2) MINIMUM 3/8" MECHANICAL ANCHORS (OR STRUCTURAL SCREWS INTO STUDS), INSTALLED PER MANUFACTURER SPECIFICATIONS AND LOCAL CODE REQUIREMENTS. PV-10.1 REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-15 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY ATTACHEMENT DATASHEET REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-14 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY OPTIMIZERS DATASHEET REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-15 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 3 2 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 4 1 0 1 4 1 3 6 AH J : S A N T A A N A C I T Y APTUS ENERGY ATTACHEMENT DATASHEET Signed-01/28/2026 EXP. 09/30/2026 REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-16 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 3 2 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 4 1 0 1 4 1 3 6 AH J : S A N T A A N A C I T Y APTUS ENERGY RAIL DATASHEET Signed-01/28/2026 EXP. 09/30/2026 3'-3" 38'-11" 3'-0" 1' - 2 " 10 ' - 8 " 1' - 6 " 4'-0" MODULE TYPE, DIMENSIONS & WEIGHT: NUMBER OF PANELS IN ARRAY = 15 MODULES MODULE TYPE = SUNKET SKT430M10-108D5 (430W) SOLAR MODULES NUMBER OF CONNECTIONS TO ROOF =44 WEIGHT OF INDIVIDUAL PANEL = 51.58 LBS / 23.4 KG. MOUNTING SYSTEM WEIGHT : 1.5 LBS. PER MODULE TOTAL WEIGHT OF ARRAY: 773.7 LBS. WEIGHT AT EACH CONNECTION : 773.7 LBS / 44 = 17.58 LBS SOLAR PANEL AREA = 67.79"X 44.64" =21.01 SF TOTAL ARRAY AREA = 15 X 21.01 = 369.60SF DISTRIBUTED LOAD = 773.7/369.60 = 3.00 PSF REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-2 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 3 2 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 4 1 0 1 4 1 3 6 AH J : S A N T A A N A C I T Y APTUS ENERGY ATTACHMENT PLAN 1 ATTACHMENT PLAN SCALE:1/4" = 1'-0" ROOF SECTION(S) TILT - 20° AZIMUTH - 180° MODULE - 15 ROOF 1 LEGEND SNAPNRACK ULTRA RAIL ATTACHEMENTS- SNAPNRACK ADJUSTABLE TILE HOOK RAFTERS 2"X8" @16" O.C ROOF #1 COMPOSITE SHINGLESROOF MATERIAL N Signed-12/08/2025 EXP. 09/30/2026 GARAGE REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-3 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 3 2 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 4 1 0 1 4 1 3 6 AH J : S A N T A A N A C I T Y APTUS ENERGY MS P IN V BL P DO O R HOUSE FLOOR PLAN SOUTH WALL WEST WALL BOLLARD PROTECTION BA T T UM (E) WINDOW AC D LEGEND JUNCTION BOXJB FENCE PROPERTY LINE CONDUIT RUN INVERTERINV ACD AC DISCONNECT BATTERYBATT UM MSP MAIN SERVICE PANEL UTILITY METER BLP BACKUP LOAD PANEL Signed-12/08/2025 EXP. 09/30/2026 REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-4 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 3 2 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 4 1 0 1 4 1 3 6 AH J : S A N T A A N A C I T Y APTUS ENERGY NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS SNAPNRACK UR-40 RAIL, TYP. L-FOOT TO BASE ATTACHMENT DOWNSLOPE FROM ROOF PENETRATION SNAPNRACK ULTRA FOOT ASSEMBLY, 92° L FOOT SHOWN, TYP. FLASHING SHIELDS ENTIRE ROOF PENETRATION 5/16" Ø LAG SCREWS S.S. COMP SHINGLE ROOFING, TYP. ROOF DECKING, TYP. WOOD RAFTER SHOWN, SIMILAR AT OTHER STRUCTURAL MEMBER TYPES SNAPNRACK ULTRA FOOT ASSEMBLY (92°) SNAPNRACK COMP FLASHING FOR L-FOOT BASE IMPORTANT: APPLY SEALANT AROUND LAG HOLE, BETWEEN THE BASE AND SHINGLE, AND ON THE LAG SCREW BEFORE MOUNTING TO ROOF. FLASHING SHOULD EXTEND TO END OF DOWNSLOPE SHINGLE COURSE SNAPNRACK COMP FLASHING MUST SLIP UNDER THE UPSLOPE SHINGLE COURSE INSTALLED VIEW UR40-PEN-D02: UR-40 PENETRATION DETAIL, FLASHED L-FOOT SNAPNRACK UR-40 PENETRATION DETAIL FOR COMP FLASHED L-FOOT ON BASE 5/16"Ø LAG SCREW MUST EMBED A MINIMUM OF 2-1/2" INTO THE ROOF STRUCTURAL MEMBER. FOR LEVELING DETAILS, PLEASE SEE SNAPNRACK DETAIL DRAWING "UR40-D01, L-FOOT LEVELING". 2-1/2" MIN. EMBEDMENT INTO WOOD MEMBER STANDOFF DETAILS Signed-12/08/2025 EXP. 09/30/2026 (N)AMENSOLAR N3H-X5US HYBRID INVERTER 20.8A, 240V DC+DC-L1L2NG GEC EXISTING GROUNDING ELECTRODE SYSTEM TO EARTH REF.NEC 250.52, 250.53(A) (N) MAIN BREAKER TO HOUSE 240 V, 100A/2P L1L1 4 (N) VISIBLE LOCKABLE 2 POLE EATON DG223NRB 100A WITH 100A FUSES 'KNIFE' AC DISCONNECT BATT 2 05 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 2 05 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 3 05 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 1 15 -SUNKET SKT430M10-108D5 430W SOLAR MODULES 15 - TS4-A-O OPTIMIZERS (N) JUNCTION BOX-1 ROOFTOP 600 V, NEMA 3-R UL LISTED 1PV WIRE (1) #6 BARE COPPER GROUND M L1 (E) 100A/2P TO UTILITY GRID (E) BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V (E) MAIN SERVICE PANEL 100A RATED, 240V (E) MAIN BREAKER TO HOUSE 240 V, 100A/2P G (N) SUNKET-ESS LFP 16kWh LOAD 3 G (N) 100A/2P (N) BACKUP LOAD PANEL 100A RATED, 240V 4 GEC EXISTING GROUNDING ELECTRODE SYSTE TO EARTH REF.NEC 250.52, 250.53(A) LINE SIDE TAP REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-5 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 3 2 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 4 1 0 1 4 1 3 6 AH J : S A N T A A N A C I T Y APTUS ENERGY SINGLE LINE DIAGRAM & CALCULATION SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # VMP IMP VOC ISC SUNKET SKT430M10-108D5 34.60 12.43 41.37 12.95 MODULE DIMENSION 67.79" L x 44.64" W INVERTER SPECIFICATIONS MANUFACTURER / MODEL #QUANTITY NOMINAL AC POWER NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENT AMENSOLAR N3H-X5US HYBRID 01 5000 240 VAC 20.8 A AMBIENT TEMPERTURE SPECIFICATIONS RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP 2%)CONDUIT HEIGHT CONDUCTOR TEMPERATURE RATE ON/OFF ROOF -2°31°7/8"90° (N) DC SYSTEM SIZE:- 15 x 430W = 6.450 kWDC (N) AC SYSTEM SIZE:- 01 x 5000W = 5.000 kWAC (15) SUNKET SKT430M10-108D5 (430W) SOLAR MODULES (01)AMENSOLAR N3H-X5US HYBRID INVERTERS (15)TS4-A-O OPTIMIZERS (03) BRANCHED CIRCUITS OF 05 MODULES CONDUCTOR SCHEDULE AND CALCULATIONS TAG LOCATION DESCRIPTION CURRENT (A)#C. CARRYING CONDUCTOR WIRE SIZE WIRE TYPE COND. RATING (A) AMBIENT TEMP COND. FILL FACTOR DERATED GROUND SIZE CONDUIT TYPE CONDUIT SIZEWIRE RUN FROM MAX. CURRENT PER STRING INVERTER OUTPUT CURRENT (A) 1 BEFORE INVERTER 16 -6 10 AWG THWN-2 35 1 0.8 28.00 10 AWG EMT 3/4" 2 BATTERY TO INVERTER -200 2 2/0 AWG THWN-2 200 1 1 200.00 4 AWG EMT 2" 3 INVERTER TO BACKUP LOAD PANEL -100 3 3 AWG THWN-2 100 1 1 100.00 8 AWG EMT 1" 4 INVERTER TO MAIN SERVICE PANEL -100 3 3 AWG THWN-2 100 1 1 100.00 8 AWG EMT 1" BATTERY SPECS MODEL SUNKET-ESS LFP 16kWh NOMINAL CAPACITY 16KWh USABLE CAPACITY 14.4KWh NOMINAL Dis/ Charge Power 10KW OPERATING VOLTAGE RANGE 43~58V NOMINAL VOLTAGE 51.2 VDC (N) AMENSOLAR N3H-X5US HYBRID INVERTER 20.8A, 240V DC+DC-L1L2NG GEC EXISTING GROUNDING ELECTRODE SYSTEM TO EARTH REF.NEC 250.52, 250.53(A) (N) MAIN BREAKER TO HOUSE 240 V, 100A/2P L1 L2 N G L1 L2 N G 4 (N) VISIBLE LOCKABLE 2 POLE EATON DG223NRB 100A WITH 100A FUSES 'KNIFE' AC DISCONNECT BATT 2 05 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 2 05 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 3 G 05 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 1 15 -SUNKET SKT430M10-108D5 430W SOLAR MODULES 15 - TS4-A-O OPTIMIZERS (N) JUNCTION BOX-1 ROOFTOP 600 V, NEMA 3-R UL LISTED 1PV WIRE (1) #6 BARE COPPER GROUND N M L2 L1 N (E) 100A/2P TO UTILITY GRID (E) BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V (E) MAIN SERVICE PANEL 100A RATED, 240V (E) MAIN BREAKER TO HOUSE 240 V, 100A/2P G (N) SUNKET-ESS LFP 16kWh LOAD 3 N G (N) 100A/2P (N) BACKUP LOAD PANEL 100A RATED, 240V 4 GEC EXISTING GROUNDING ELECTRODE SYSTE TO EARTH REF.NEC 250.52, 250.53(A) LINE SIDE TAP SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #VMP IMP VOC ISC SUNKET SKT430M10-108D5 34.60 12.43 41.37 12.95 MODULE DIMENSION 67.79" L x 44.64" W INVERTER SPECIFICATIONS MANUFACTURER / MODEL #QUANTITY NOMINAL AC POWER NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENT AMENSOLAR N3H-X5US HYBRID 01 5000 240 VAC 20.8 A REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-6 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY THREE LINE DIAGRAM & CALCULATION AMBIENT TEMPERTURE SPECIFICATIONS RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP 2%)CONDUIT HEIGHT CONDUCTOR TEMPERATURE RATE ON/OFF ROOF -2°31°7/8"90° (N) DC SYSTEM SIZE:- 15 x 430W = 6.450 kWDC (N) AC SYSTEM SIZE:- 01 x 5000W = 5.000 kWAC (15) SUNKET SKT430M10-108D5 (430W) SOLAR MODULES (01) AMENSOLAR N3H-X5US HYBRID INVERTERS (15) TS4-A-O OPTIMIZERS (03) BRANCHED CIRCUITS OF 05 MODULES CONDUCTOR SCHEDULE AND CALCULATIONS TAG LOCATION DESCRIPTION CURRENT (A)#C. CARRYING CONDUCTOR WIRE SIZE WIRE TYPE COND. RATING (A) AMBIENT TEMP COND. FILL FACTOR DERATED GROUND SIZE CONDUIT TYPE CONDUIT SIZEWIRE RUN FROM MAX. CURRENT PER STRING INVERTER OUTPUT CURRENT (A) 1 BEFORE INVERTER 16 -6 10 AWG THWN-2 35 1 0.8 28.00 10 AWG EMT 3/4" 2 BATTERY TO INVERTER -200 2 2/0 AWG THWN-2 200 1 1 200.00 4 AWG EMT 2" 3 INVERTER TO BACKUP LOAD PANEL -100 3 3 AWG THWN-2 100 1 1 100.00 8 AWG EMT 1" 4 INVERTER TO MAIN SERVICE PANEL -100 3 3 AWG THWN-2 100 1 1 100.00 8 AWG EMT 1" BATTERY SPECS MODEL SUNKET-ESS LFP 16kWh NOMINAL CAPACITY 16KWh USABLE CAPACITY 14.4KWh NOMINAL Dis/ Charge Power 10KW OPERATING VOLTAGE RANGE 43~58V NOMINAL VOLTAGE 51.2 VDC REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-7 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY STRING MAP (15) TS4-A-O OPTIMIZERS SCALE:1/8" = 1'-0" VARIES STRING #1 STRING #3 (15) SUNKET SKT430M10-108D5 (430W) SOLAR MODULES (01) AMENSOLAR N3H-X5US HYBRID INVERTERS (15) TS4-A-O OPTIMIZERS (03) BRANCHED CIRCUITS OF 05 MODULES STRING #2 REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-8 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY PLACARD & WARNING LABELS POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN MULTIPLE SOURCES OF POWER CAUTION ! 3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA N (E) UTILITY METER (N) BACKUP LOAD PANEL (N) INVERTER (N) BATTERY MS P IN V BL P BA T T UM(E) MAIN SERVICE PANEL WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: CEC690.31(D)(2) PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: POINT OF INTERCONNECTION PRODUCTION METER CEC 705.12(B)(3)(3) & CEC 690.59) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: CEC 706.15 (C)(4)& CEC 690.13(B) LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2022: 690.56(C)(2) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): CEC 2022: IFC 690.56(C) ! 4" 3" WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.13(B)) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: MAIN SERVICE DISCONNECT / UTILITY METER (PER CODE: CEC 690.13(B)) 2022 CEC CODE 690.53 MAXIMUM DC VOLTAGE OF PV SYSTEM THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING LABEL LOCATION: POINTS OF CONNECTION/BREAKER CODE: CEC 705.12(B)(3)(3) LABEL LOCATION: MSP (PER CODE: CEC 705.12(D) & CEC 690.59 CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE ! LABEL LOCATION: SERVICE PANEL IF SUM OF BREAKERS EXCEEDS PANEL RATING CEC 705.12 (B)(3)(2) ! ! ! MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 20.80 AMPS 240 VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54 PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT/BREAKER/ POINT OF CONNECTION (PER CODE: CEC 690.13(B) WARNING DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT LABEL LOCATION: INVERTER PER CODE: CEC 690.31(E) ! LABEL LOCATION: INVERTER PER CODE(S): CEC 2022: 690.54 MEGAREVO R12KLNA SYSTEM SIZE RATED OUTPUT POWER: 5 KW MAX APPARENT POWER (GRID SIDE): 5.5 KVA MAX PV INPUT POWER: 7.5 KW RATED AC VOLTAGE: 120/240V SPLIT PHASE AC D (N) UTILITY AC DISCONNECT REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-9 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY ELEVATION 1. MINIMUM 18” CLEARANCE REQUIRED ON BOTH SIDES OF THE EXISTING UTILITY METER. 2. MINIMUM 12” CLEARANCE REQUIRED ON BOTH SIDES OF THE PROPOSED AC DISCONNECT. 3. ALL EQUIPMENT MUST BE MOUNTED 48” – 66” ABOVE GRADE. 4. EQUIPMENT SHALL BE A MINIMUM OF 3' X 3' ACCESSIBLE WORKSPACE, FLAT, AND CLEAR OF DEBRISAND OBSTACLES (TREES, BUSHES, PLANTS, ETC) 5. BATTERIES TO BE SEPARATED BY A MINIMUM OF 3" BETWEEN EACH UNIT PER UL 9540A REPORT AND/OR MANUFACTURER SPECIFICATIONS, WHICHEVER IS GREATER DISTANCE 6. EXTERIOR ESS UNIT(S) WILL NOT BE INSTALLED WITHIN 3 FEET (IN ANY DIRECTION) OF ALL DOORS, WINDOWS, OPERABLE OPENINGS INTO BUILDING AND HVAC INLETS 7. DIAGRAM NOT TO SCALE M 100A BACKUP LOAD PANEL AMENSOLAR N3H-X5US HYBRID INVERTER SUNKET-ESS LFP 16kWh BATTERYMAIN SERVICE PANEL FROM SOLAR WINDOW EXTERIOR WEST WALL UTILITY METER 100A AC DISCONNECT FROM ACD TO MSP REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-10 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY MAIN PANEL PHOTO REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-11 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY MODULE DATASHEET REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-12 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY INVERTER DATASHEET Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA Joshua Nolasco 3606 S Van Ness 1/26/2026 sales@tantaoenergy.com VIEKO INNOBUILD INC 1138900 3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA Design Criteria: 10/14/2025 APTUS ENERGY. Attn.: To Whom It May Concern re job: YE ZHU The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set. The verification of such info is the responsibility of others. After review, I certify that the roof structure has sufficient structural capacity for the applied PV loads. All mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Code 2022 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Dr 10 psf V 95 mph DPV Exposure B Lr Roof Dead Load PV Dead Load Roof Live Load Ground Snow S 3 psf 20 psf 0 psf Signed-10/14/2025 EXP. 09/30/2026 2 of 5 Roof Properties: Roof Type = Roof Pitch (deg) = Mean Roof Height (ft) = Attachment Trib Width (ft) = Attachment Spacing (ft) = Framing Type = Framing Size = Framing OC Spacing (in.) = Section Thickness, b (in.) = Section Depth, d (in.) = Section Modulus, Sx (in.^3) = Moment of Inertia, Ix (in.^4) = Framing Span (ft) = Deflection Limit D+L (in.) = Deflection Limit S or W (in.) = Framing Upgrade = Sister Size = Wood Species = Wood Fb (psi) = Wood Fv (psi) = Wood E (psi) = CD (Wind) = CD (Snow) = CM = Ct = CL = Ci = CF = Cfu = Cr = F'b_wind (psi) = F'b_snow (psi) = F'v_wind (psi) = F'v_snow (psi) = M_allowable_wind (lb-ft) = M_allowable_snow (lb-ft) = V_allowable_wind (lbs) = V_allowable_snow (lbs) = E' (psi) = 12 2.4 1.60 Adequate NA DF #2 900 180 1600000 1.6 1.15 1.0 1.3 1.00 1.15 2153 1547 288 207 1357 975 1584 1139 1600000 1.5 5.4 7.6 20.6 4 Rafters 2x8 16 13 3.25 Comp. Shingle 20 Roof Signed-10/14/2025 EXP. 09/30/2026 3 of 5 Wind Load Cont. 95 mph B 1.0 0.96 0.83 0.87 ASCE 7-16 Figure 26.5-1B ASCE 7-16 Sec 26.8.2 ASCE 7-16 Table 26.10-1 ASCE 7-16 Table 26.6-1 ASCE 7-16 Table 26.9-1 24.37 psf 20.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1) Zone(2r) Zone(2e)Zone(3) Fig. 30-3-2 -2.1 -2.6 -2.7 -2.7 Eq. 29.4-7 -43.86 -49.78 -41.53 -47.54 0.3 Figure 30.3-2 GCp= P=qh(GCp)(γE)(γa)= GCp= P=qh(GCp)(γE)(γa)=6.68 Equation 29.4-7 Rafters Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachment max. spacing=4 ft 5/16" Ø LAG SCREWS S.S. Withdrawal Value=266 lbs/in 2.5 in Table 12.2A - NDS DFL Assumed Prying Coefficient Allowable Capacity= Zone Trib Width Area (ft) 1.4 740 lbs Uplift(lbs)Down (lbs) Zone(1)4 11.0 85.6 Zone(2r)4 11.0 Zone(2e)4 11.0 Zone(3)4 11.0 85.6 85.6 85.6 Conservative Max= 132.8 209.6 217.5 216.4 <740 CONNECTION IS OK Risk Category = V= Exposure = KZt = KZ = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. II Kd = Ke = qh= 0.00256KzKztKdKeV2= Pitch = γE= γa= Lag Screw Penetration 215.6 4 of 5 Vertical Load Resisting System Design Roof Framing Rafters Snow Load Fully Exposed pg=0 psf Ct =1.1 Ce =0.9 Is =1.0 pf = 3 psf pfmin. = 3.2 psf ps = 1 psf Conservatively (Cs=1)0.6 plf Max Length, L = 8.0 ft (Rafter maximum Allowable Horizontal Span) 16 in 10 psf 20 plf Tributary Width, WT = Dr = PvDL =3 psf 12 plf Load Case: DL+0.75(0.6W+S) 0.75(Pnet+Ps)+ Ppvcos(θ)+PDL=41 plf Mdown=328 lb-ft 975 lb-ft >253 lb-ft OKMallowable = Sx x Fb' (wind)= Load Case: DL+S Ps+ Ppvcos(θ)+PDL=38 plf Mdown=306 lb-ft 975 lb-ft >241 lb-ft OKMallowable = Sx x Fb' (wind)= Load Case: DL+0.6W Pnet+ Ppvcos(θ)+PDL=37.7 plf Max Moment, Mu=302 lb-ft Mallowable = Sx x Fb' (wind)=1357 lb-ft >276 lb-ft OK Pv max Shear=85.6 lbs 242 lbsShear, Vu=wL/2+Pv Point Load = Max Shear, Vu=wL/2+Pv Point Load = 217 lb Member Capacity DF-L No.2 2X8 CL CF Ci Cr KF φ λ Fb =900 psi 1.0 1.3 1.0 1.15 2.54 0.85 0.8 1346 psi Fv =180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E =1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin =580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi 5.5 in 1.5 in Depth, d = Width, b = Cross-Sectonal Area, A =7.25 in2 Moment of Inertia, Ixx =Section Modulus, Sxx =7.5425 in20.7469 in4 3 848.5 lb-ft SatisfactoryAllowable Moment, Mall = Fb'Sxx = Allowable Shear, Vall = 2/3Fv'A =990.1 lb DCR=Mu/Mall =0.34 < 1 DCR=Vu/Vall =0.22 < 1 Satisfactory Design Value Adjusted Value 5 of 5 Existing structure is assumed to have been designed and constructed following appropriate codes at time of erection, and assumed to have appropriate permits. The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience, opinions and judgements. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work. All PV modules, racking, and mounting equipment shall be designed and installed per manufacturer's approved installation specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any concerns prior to starting construction. Siesmic Loads Check Roof Dead Load 10 psf 13.21% 3 psf 8.1 psf % or Roof with Pv Dpv and Racking Average Total Dead Load Increase in Dead Load 3.6% OK