Loading...
HomeMy WebLinkAbout2422 W Marty Ln Unit 2 & 3 REV1 - Plan(N) 4 " A B S S E W E R L I N E , MIN . 2 % S L O P E (E ) 4 " S E W E R L I N E TO S T R E E T ( V . I . F . ) (N) WATER LINE: 1" COPPER TYPE "L" OR PVC PIPE, MIN. 18" BELOW GROUND (N) ADU 799 SF 2 BED/2 BATH (N) JADU 431 SF 1 BED/1 BATH (E) WATER METER (E) 100A PANEL CHANGED TO 100A SUB-PANEL (E) GAS METER (E) POWER POLE PROPERTY LINE - 75.00' PR O P E R T Y L I N E - 8 9 . 1 9 ' PR O P E R T Y L I N E - 1 0 8 . 2 1 ' 6'H METAL GATE (E) 6'H WOODEN FENCE (E ) 6 ' H B L O C K W A L L 9'-1"27'-4"4'-0" 19'-7" 30'-3" 7'-0" 35'-5" 25'-0" TO CENTERLINE ℄ W MARTY LN 25'-0" 36'-3" 7'-0" (E) 1-STORY MAIN UNIT 1,248 SF 4 BED/2 BATH 4: 1 2 4: 1 2 (E) GARAGE 353 SF 4:12 4:12 (E) PORCH 23 SF 18" (TYP.) 5'-0" (E) DRIVEWAY AND IMPERVIOUS SURFACE 20'-11"9'-1"18'-0"3'-6"4'-6" 34'-7" 18'-8"17'-3"4'-0" 5'-0"6'-0" 3'-0" 10'-0" 3'-0" 17'-4" 4: 1 2 FRONT YARD LANDSCAPING (PER S.A.M.C. SEC. 41-240) 12" (TYP. @ JADU) FI R E S E P A R A T I O N LI N E PU B L I C U T I L I T Y EA S E M E N T ( 5 ' & 6 ' ) 14 SD-2 1-HR RATED OVERHANG AND WALL 14 SD-2 ADDRESS NUMBER (N ) 2 - G A N G P A N E L , 10 0 A E A C H F O R JA D U A N D M A I N U N I T (N ) A D U 20 0 A P A N E L (N) 1" WATER METER (N) JADU 100A SUB-PANEL 3'-0" (N ) A C (N ) A C 12" (TYP. @ ADU) 3'-0" 2: 1 2 2: 1 2 4:124:12 4:124:12 4: 1 2 4: 1 2 4: 1 2 2 A3 1 A3 14 SD-2 1-HR RATED OVERHANG AND WALL 1-HR RATED OVERHANG AND WALL 14 SD-2 1-HR RATED OVERHANG AND WALL 2'-0" 2'-0" 12" OVERHANG TO BE TRIM TO BE 12" FOR FIRE SEPARATION NEW WATER METER AND SERVICE WILL BE APPROVED UNDER A SEPARATE PERMIT (N) GAS METER (N) GAS METER (N) ADU GAS LINE: 1-1/4" MDPE PRESSURE PIPE, 18" MIN. BELOW GROUND 1 1 ATTIC VENTILATION CALCULATION TOTAL ATTIC VENTILATION AREA SHALL NOT BE LESS THAN 1/150 OF THE ATTIC SPACE AREA. 1. ADU: ATTIC SPACE = 799 SF ATTIC VENTS REQUIRED = 799/150 = 5.33 SF 2. JADU: ATTIC SPACE = 431 SF ATTIC VENTS REQUIRED = 431/150 = 2.9 SF ===> PROVIDE 6 VENTS ON THE ADU AND 3 VENTS ON THE JADU, OHAGINTM 14" DIAMETER ROOF VENTS (1.07 SF EACH), AS INDICATED ON ROOF PLAN HEREON ===> ALSO PROVIDE 3 VENTS ON THE MAIN HOUSE, OHAGINTM 14" DIAMETER ROOF VENTS (1.07 SF EACH), TO ACCOUNT FOR THE VENT LOSS FROM THE NEW BUILDING ATTACHMENT PROJECT INFORMATION OWNER:TT STARS LLC C/O:TOAN TRAN TEL.:(714) 548 1711 ADD.:MAIN:2422 W MARTY LN JADU: 2422 W MARTY LN, UNIT 2 ADU: 2422 W MARTY LN, UNIT 3 SANTA ANA, CA 92706 (E) MAIN UNIT = 1,248 SF (E) GARAGE = 353 SF (E) PORCH = 23 SF (N) JADU = 431 SF (N) ADU = 799 SF (EXEMPT FROM LOT COVERAGE) LOT COVERAGE = 1,248 + 353 + 431 = 2,032 SF LIVING AREA = 1,248 + 431 + 799 = 2,478 SF LOT SIZE = 7,405 SF % COVERAGE = 2,032/7,405 = 27.4% < 35.0% APN = 399-141-14 ZONE = R1/U OCCUPANCY = MAIN UNIT: R-3/U, ADU: R-3 FLOOD ZONE = X NUMBER OF STORY = 1 TYPE OF CONSTRUCTION = VB (E) UNIT AND ADU FIRE SPRINKLER = NOT EQUIPPED APPLICABLE BUILDING STANDARDS 1. 2022 CALIFORNIA MECHANICAL CODE (CMC) 2. 2022 CALIFORNIA BUILDING CODE (CBC) 3. 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 4. 2022 CALIFORNIA PLUMBING CODE (CPC) 5. 2022 CALIFORNIA ELECTRICAL CODE (CEC) 6. 2022 CALIF. ENERGY EFFICIENCY STANDARD 7. 2022 CALIF. GREEN BUILDING STANDARDS 8. CITY OF SANTA ANA ORDINANCES REVISION DRAWING INDEX A1-R REVISED SITE/ROOF PLAN - GENERAL NOTES A3-R REVISED (N) FLOOR PLAN T1-3-R TITLE 24 PLAN SCOPE OF WORK 1. BUILD NEW ATTACHED 799 SF ADU (2 BEDROOM - 2 BATHROOM) 2. BUILD NEW ATTACHED 431 SF JADU (1 BEDROOM - 1 BATHROOM) 3. RELOCATE EXISTING 100A PANEL TO ADU CONSTRUCTION NOTES 1. CONSTRUCTION WORK HOURS ARE 7AM - 7PM, M-F; 9AM - 7PM, SATURDAY; NO SUNDAY OR LEGAL HOLIDAYS. 2. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5' OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND, OR OBTAIN PERMIT FROM STATE OF CA, DIVISION OF OCCUPATIONAL SAFETY AND HEALTH (CAL/OSHA). THIS PERMIT AND ANY OTHER SAFETY PERMIT SHALL BE OBTAINED PRIOR TO COMMENCE OF ANY WORK. VICINITY MAP ADU PARKING EXEMPTION NOTE PROPOSED ADU IS LOCATED WITHIN ONE-HALF MILE TO OCTA ROUTE 47 ALONG FAIRVIEW ST. AT DOWNIE PL., PURSUANT TO ASSEMBLY BILL 68, NO PARKING IS REQUIRED FOR THE ADU. GENERAL NOTES 1. ALL WORK PERFORMED SHALL COMPLY WITH THESE GENERAL NOTES (UNLESS NOTED OTHERWISE ON THESE PLANS AND SPECIFICATIONS) AND ALL THE FOLLOWING NOTES, DRAWINGS AND SPECIFICATIONS. GENERAL CONTRACTOR SHALL COORDINATE THE INTENT OF GENERAL NOTES WITH MECHANICAL, ELECTRICAL, AND PLUMBING TRADES. 2. THE GENERAL CONTRACTOR OBTAINS AND PAYS FOR ALL REQUIRED PERMITS AND ARRANGES FOR ALL REQUIRED INSPECTIONS. 3. ALL WORK SHALL COMPLY WITH LATEST EDITION OF BUILDING CODES AS ADOPTED BY THE CITY OF SANTA ANA AND ALL OTHER APPLICABLE REGULATIONS. 4. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL SITES CONDITIONS, DIMENSIONS AND ELEVATION BEFORE STARTING THE WORK, AND NOTIFY THE DESIGNER OF ANY DISCREPANCY, IN WRITING, PRIOR TO PROCEEDING. 5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PROSECUTION OF SUCH WORK. 6. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF THE UTILITY SERVICES IN THE AREA TO BE EXCAVATED PRIOR TO THE EXCAVATION. 7. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITE OR BY THE CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. 8. ALL NEW ROOF MATERIALS, STUCCO AND WINDOWS SHALL MATCH EXISTING COLOR AND STYLE. EMERGENCY EGRESS NOTES 1. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. 2. MIN. 5 SQUARE FEET FOR GRADE-FLOOR OPENINGS 3. MIN. SET CLEAR HEIGHT OF 24 INCHES. 4. WINDOW TO BOTTOM OF CLEAR OPENING SHALL BE NO MORE THAN 44 INCHES. STUCCO NOTES 1. A CORROSION RESISTANT WEEP SCREED 2" BELOW PLATE, 6" (2" FOR CONCRETE WALKWAY) ABOVE GRADE THAT ALLOWS TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING IS REQUIRED BELOW THE STUCCO AT THE FOUNDATION PLATE LINE. 2. 7/8" MIN. THICK THREE-COAT APPLICATION (SCRATCH, BROWN AND FINISH) OVER SELF-FURRING GALVANIZED WIRE LATH OVER GRADE D BUILDING PAPER AND WIRE BACKING. 3. EXTERIOR LATH: PROVIDE 2 LAYERS OF GRADE D PAPER OVER SHEATHING OR WOOD STUDS. SETBACK AND PROPERTY LINE NOTE THE OWNER/CONTRACTOR SHALL CONSULT WITH A LAND SURVEYOR TO DETERMINE IF A LOT/BOUNDARY SURVEY IS NEEDED TO VERIFY SETBACKS OF EXISTING AND PROPOSED STRUCTURES WITH RESPECT TO PROPERTY LINES. IN THE EVENT THERE IS DISCREPANCY BETWEEN PROPOSAL AND FIELD MEASUREMENTS OF SETBACK, THE DESIGNER SHALL BE NOTIFIED; AND REVISION SHALL BE SUBMITTED FOR CITY APPROVAL. ELECTRICAL METER RELOCATION NOTE THE CONTRACTOR SHALL CONTACT SOUTHERN CALIFORNIA EDISON (SCE) @ 800-655-4555 TO OBTAIN A NEW METER SPOT APPROVAL AND INSTALLATION INSTRUCTIONS PRIOR TO INSTALLING THE NEW METER SERVICE PANEL. LOCATION AND AMPERAGE OF NEW METER IN THIS PLAN ARE ONLY PROPOSAL AND SUBJECT TO SCE FINAL APPROVAL. RE V I S E D SI T E P L A N RO O F P L A N GE N E R A L N O T E S OW N E R TT S T A R S L L C TE L : ( 7 1 4 ) 5 4 8 1 7 1 1 PR O J E C T A D D R E S S MA I N U N I T : 2 4 2 2 W M A R T Y L N JA D U : 2 4 2 2 W M A R T Y L N , U N I T 2 AD U : 2 4 2 2 W M A R T Y L N , U N I T 3 SA N T A A N A , C A 9 2 7 0 6 DATE 1/5/2026 NE W A T T A C H E D 7 9 9 S F A D U AN D A T T A C H E D 4 3 1 S F J A D U SHEET A1-R REVISION DATE BY 1 1/5/2026 ALL 2 3 PROJECT ENGINEER BEN PHAN 10822 WOODWARD LN GARDEN GROVE, CA 92840 TEL: (714) 251 4537 LANDSCAPING LEGEND GRASS OR ACCEPTABLE DRY CLIMATE GROUND COVER POP-UP SPRINKLER NEW 5 GAL. JUNIPER BUSH (TYP. 6) NEW 1 GAL. ENCORE AZALEA (TYP. 10) FRUIT TREES ( VARIETY - MAX. 20' APART) NEW 24" BOX KING PALM OR SIMILAR, TREE SHALL BE DOUBLE-STAKED BUILDING NOTES 1. ALL CONCEALED WORK INSTALLED WITHOUT PERMITS MUST BE EXPOSED FOR INSPECTION TO THE SATISFACTION OF THE BUILDING INSPECTOR. THIS INCLUDES METHODS OF ATTACHMENT AND ALL FOOTINGS, STRUCTURAL MEMBERS, MECHANICAL, ELECTRICAL, PLUMBING AND INSULATION. 2. MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF THIS PLAN REVIEW AND APPROVAL. MEP ARE SUBJECT TO BUILDING FIELD INSPECTION. FRONT YARD NOTES 1.FRONT YARD LANDSCAPING SHALL COMPLY WITH S.A.M.C. SEC. 41-240. 2.LANDSCAPING AREAS SHALL BE DESIGNED WITH AN AUTOMATIC IRRIGATION SYSTEM WITH POP-UP SPRINKLERS. DRIP, BUBBLER OR OTHER LOW GALLONAGE SYSTEMS MAY BE USED IN BUFFER AREAS AND NARROW STRIPS. 3.FRONT YARD LANDSCAPING, IF NOT PRESENT, SHALL BE RESTORED WITH LIVE VEGETATION (GRASS OR ACCEPTABLE DRY CLIMATE GROUND COVER). 4.FENCE IN FRONT YARD SHALL COMPLY WITH S.A.M.C. SEC. 41-610 AND SHALL NOT EXCEED 3' IN HEIGHT. REVISED (N) SITE/ROOF PLAN SCALE: 1/8" = 1'-0" ADU SF / SFD SF RATIO ADU SF / SFD SF RATIO = 799/1,248 = 0.64 THE ADU SF / SFD SF RATIO IS FOR PARK & REC. FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN "SFR SF" OF THE EXISTING PRIMARY RESIDENCE. BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN "SFR SF" OF THE EXISTING RESIDENCE. BUILDING DEPARTMENT NOTE FOR NEW BUILDINGS AND ADDITIONS, ALTERATIONS, AND REPAIRS WITHIN ANY TWELVE-MONTH PERIOD EXCEED FIFTY (50%) PERCENT OF THE VALUE OF ANY EXISTING BUILDING OR STRUCTURE, EACH BUILDING OR STRUCTURE SHALL BE MADE TO CONFORM TO THE REQUIREMENTS FOR NEW BUILDINGS OR STRUCTURES AND COMPLY WITH THE BUILDING SECURITY REGULATIONS. SANTA ANA MUNICIPAL CODE CHAPTER 8, DIVISION 3. PLANNING NOTE THE PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND/OR CLEARANCE ON-SITE THAT MAY AFFECT THE PROJECT. HERS SPECIAL FEATURES • INSULATION BELOW ROOF DECK • NORTHWEST ENERGY EFFICIENCY ALLIANCE (NEEA) RATED HEAT PUMP WATER HEATER; SPECIFIC BRAND/MODEL, OR EQUIVALENT, MUST BE INSTALLED HERS INSPECTION FEATURES • QUALITY INSULATION INSTALLATION (QII) • INDOOR AIR QUALITY VENTILATION • VERIFIED HEAT PUMP RATED HEATING CAPACITY SCOPE OF REVISION # 1 REVISE SITE PLAN TO PROPOSE NEW GAS METERS AND GAS LINES FOR THE NEW ADU AND JADU 1 S-S JADU 100A SUB-PANEL HOOD VENT THROUGH ROOF, 400 CFM MIN., INSTALLED PER MANU. SPECS. HOOD SHALL COMPLY W/ ASHRAE 62.2(C) LUMINAIRES LOCATED ABOVE BATHTUB OR SHOWER SHALL BE LISTED FOR WET LOCATIONS SMOKE DETECTOR IN LIVING ROOM (WITHIN 20' FROM THE COOK TOP) SHALL BE IONIZED OR PHOTOELECTRIC TYPE WALLS AT SHOWERS SHALL BE TILE/CEMENT PLASTER, MINIMUM 72" ABOVE FLOOR. GRAB BAR REINFORCEMENT, MIN. 2x8 LUMBER, 32"-39.25" ABOVE F.F. (TYP.) SD 40 AMP.GAS RANGE TEMP. GLASS EATON 2-POLE SPD OR APPROVED COMPATIBLE (N) 100A SUB-PANEL WH (E) BEDROOM 1 (E) BEDROOM 2 (E) BEDROOM 3 (E) BEDROOM 4 ( E ) B A T H 2 (E) BATH 1 (E) KITCHEN (E) DINING AREA (E) LIVING AREA (E) GARAGE ATTIC ACCESS UL 2034/2075 RATED @ (E) HOUSE CO SD SD SD SD SD UL 217 RATED @ (E) HOUSE (TYP.) SD (E) 36"48" VINYL WINDOW (E) 36"48" VINYL WINDOW (E) 36"48" VINYL WINDOW (E) 36"48" VINYL WINDOW (E) 36"48" VINYL WINDOW (E) 36"12" VINYL WINDOW (E) 30"48" VINYL WINDOW (E) 36"48" VINYL WINDOW (E) 36"48" VINYL WINDOW (E) 36"48" VINYL WINDOW (E) 36"48" VINYL WINDOW ( E ) 3 6 " 3 6 " V I N Y L WI N D O W ( E ) 3 6 " 3 6 " V I N Y L WI N D O W ( E ) 3 6 " 3 6 " V I N Y L W I N D O W ( E ) 3 0 " 4 8 " V I N Y L WI N D O W (E) 15'7' GARAGE DOOR W/ AUTO. OPENER (E) PORCH 21'-9" 49'-10" 30'-3" 19'-7" 18'-8"3'-6"18'-0" 61'-11" 4'-6" WALL HEATER 10'-0" (N) LIVING AREA (N ) B A T H 2 STACKED W/D 2' - 2 " STACKED W/D 30" 1,024 SI 1'-6" 1'-6" 1'-7" (N) BEDROOM 1 (N) BEDROOM 2 (N) BEDROOM (N) LIVING AREA (N) KITCHEN (N ) K I T C H E N (N) BATH 1 (N) BATH 15'-0" 11'-3" 2'-6" 5'-7" 16'-11" 17'-3" 9'-4" 9'-2" 7'-0" 61'-3" 2'-6"11'-11" 17'-4" 10'-0" 34'-7" 1' - 6 " 5'-4" 3'-7" 14'-10" (N ) A C CO N D E N S E R O N 3" C O N C R E T E P A D (N ) A C CO N D E N S E R O N 3" C O N C R E T E P A D (N ) 2 - G A N G PA N E L , 1 0 0 A EA C H F O R J A D U AN D M A I N U N I T (N ) A D U 22 5 A R A T E D 20 0 A P A N E L 3" EATON 2-POLE SPD OR APPROVED COMPATIBLE EATON 2-POLE SPD OR APPROVED COMPATIBLE ATTIC ACCESS 22" x 30" ATTIC ACCESS 22" x 30" 3'-0" 3"5'-0" 5'-0" 3'-0" EGRESS WINDOW EGRESS WINDOW EGRESS WINDOW 30" 1,024 SI 30" 1,024 SI 3'-0" 6'-0" 1 A3 2 A3 1 A3 1" GAP BETWEEN 2x4 LUMBER 1" GAP BETWEEN 2x4 LUMBER 40 AMP. 30 AMP. 50 AMP. 30 AMP. $$ S-S DU C T L E S S M I N I SP L I T A C DUCTLESS MINI SPLIT AC DU C T L E S S M I N I SP L I T A C DU C T L E S S M I N I SP L I T A C DU C T L E S S M I N I SP L I T A C SD SD CO SD CO SD SD MAX. 48" MEASURED FROM TOP, MIN. 15" MEASURED FROM BOTTOM OF BOX ABOVE F.F. (TYP.) AFCI (TYP.) AFCI (TYP.) AFCI (TYP.) GAS DRYER GAS DRYER GAS RANGE WR-GFCI WR-GFCI WR-GFCI AFCI (TYP.) GFCI (TYP.) 2'-7" $VS$ 5'-3" 7'-0" $VS$ $D $D $ $4D $3 $$4 $4 $3 $VS $ $D AFCI (TYP.) AFCI (TYP.) 30 AMP. 30 AMP. 50 AMP. $$ AFCI (TYP.) GFCI (TYP.) $ $3 $3 $$3D$3 2'-6" 6'-3" HOOD VENT THROUGH ROOF, 400 CFM MIN., INSTALLED PER MANU. SPECS. HOOD SHALL COMPLY W/ ASHRAE 62.2(C) DOOR SHALL BE TEMPERED AND SWING INWARD (TYP.) WH INDOOR INSTANTANEOUS WH, 0.87 EFFICIENCY, ON 1" DEDICATED GAS LINE WH INDOOR INSTANTANEOUS WH, 0.87 EFFICIENCY, ON 1" DEDICATED GAS LINE1 1 1 1 1 1 NEW WALL, 2x4 STUDS @ 16" O.C. U.N.O. EXISTING STUD WALL WALL LEGEND CARBON MONOXIDE AND SMOKE DETECTOR NOTES SMOKE DETECTOR SHALL BE PROVIDED IN EACH SLEEPING ROOM AND AREA GIVING ACCESS TO THE SLEEPING ROOMS 1. NEW CONSTRUCTION: CO AND SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM BUILDING WIRING WITH BATTERY BACKUP. 2. EXISTING MAIN HOUSE: BATTERY POWERED UL 2034/2075 RATED CARBON MONOXIDE ALARM AND UL 217 RATED SMOKE ALARMS SHALL BE INSTALLED IN MARKED LOCATIONS. ELECTRICAL NOTES 1.PROVIDE ONE 20 AMP. CIRCUIT FOR BATHROOM OUTLETS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. 2.PROVIDE 2 DEDICATED GENERAL APPLIANCE CIRCUITS TO THE KITCHEN AREA. 3.ALL INSTALLED LUMINAIRES MUST BE HIGH EFFICACY IN ACCORDANCE WITH TABLE 150.0-A. 4.ALL RECEPTACLES IN BATHROOMS SHALL BE G.F.C.I. 5.SERVICE PANEL/METER UPGRADE OR NEW: OBTAIN LOCATION APPROVAL FROM THE ELECTRICAL PROVIDER. 6.ALL BRANCH CIRCUITS SUPPLYING RECEPTACLE OUTLETS IN KITCHENS, BEDROOMS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, DENS, SUNROOMS, HALLWAYS, CLOSETS AND SIMILAR ROOMS/AREAS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER (AFCI). 7.NON-HIGH EFFICACY LUMINAIRES SHALL BE SWITCHED ON A SEPARATE CIRCUIT FROM HIGH EFFICACY LUMINAIRES. 8.ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED HORIZONTALLY BY 24" . BACK AND SIDES OF BOXES TO BE SEALED WITH 1/8" RESILIENT SEALANT AND BACKED WITH 2" MIN. MINERAL FIBER INSULATION. 9.ALL RECEPTACLE OUTLETS SHALL BE LISTED AS TAMPER-RESISTANT OUTLETS. 10.ALL OUTDOOR LIGHTING MOUNTED TO A RESIDENTIAL BUILDING SHALL BE HIGH EFFICACY LIGHTING OR CONTROLLED BY A PHOTOCELL AND MOTION SENSOR COMBINATION. PLUMBING NOTES 1.BATH FAN SHALL BE CONTROLLED BY HUMIDISTAT WITH ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE 50-80%. 2.SHOWER WALLS ABOVE BATHTUB WITH SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 6' ABOVE FLOOR. 3.SHOWER COMPARTMENT SHALL BE MINIMUM 1,024 SQ. IN. AND SHALL BE CAPABLE OF ENCOMPASSING A 30 IN. CIRCLE. 4.PROVIDE A 12"x12" MINIMUM ACCESS PANEL TO BATHTUB TRAP CONNECTION UNLESS PLUMBING IS WITHOUT SLIP JOINTS (CPC 405.2). 5.ALL TOILETS SHALL BE 1.28 GPF, SHOWERHEADS 2.0 GPM, AND FAUCETS 1.2 GPM, KITCHEN FAUCET 1.8 GPM. 6.FOR SHOWERS OR TUB-SHOWERS MAX. TEMPERATURE OF 120 DEGREE TO BE PROVIDED BY THE USE CONTROL VALVE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE. 7.ALL GLAZING IN ALL DOORS, BATH/SHOWER ENCLOSURES MUST BE IDENTIFIED BY A LABEL AS A SAFETY GLAZING. 8.WALL COVERING IN SHOWERS AND TUBS TO BE CEMENT PLASTER OR TILE EQUAL TO 72" ABOVE DRAIN. ENCLOSURES MUST BE OF APPROVED SAFETY GLAZING AND DOORS MUST SWING OUT OF SHOWERS. WINDOWS IN ENCLOSURE WALLS SHALL BE LABELED SAFETY GLAZING WHEN LESS THAN 60" ABOVE THE DRAIN, TYPICAL FOR ALL BATHROOMS. 9.GREEN BOARD GYPSUM OR WATER RESISTANT GYPSUM BOARD SHALL NOT BE USED AS BACKING FOR CEILING FINISH INSIDE BATHROOM DUE TO CONDENSATION OR VAPOR. 10.WATER HEATER: SIZE PER TITLE 24 WITH VENT THROUGH OUTSIDE. PROVIDE P&T RELIEF VALVE ON WATER HEATER. PROVIDE SMITTY PAN WITH DRAIN INSULATION/CLEARANCE PER MANUFACTURER SPECS. WATER HEATER TANK (IF USED) MUST BE ADEQUATELY BRACED TO RESIST SEISMIC FORCES: PROVIDE 2 STRAPS, 1 STRAP AT TOP 1/3 OF TANK AND 1 STRAP AT BOTTOM 1/3 OF THE TANK. 11.PLUMBING VENT TERMINATIONS SHALL BE AT LEAST 10' FROM FRESH AIR INTAKE OR VENTILATION. 12.B-VENTS SHALL TERMINATE AT LEAST 4' FROM FRESH AIR INTAKE OR VENTILATION. RE V I S E D N E W FL O O R P L A N SHEET A3-R REVISION DATE BY 1 1/5/2026 ALL 2 3 PROJECT ENGINEER BEN PHAN 10822 WOODWARD LN GARDEN GROVE, CA 92840 TEL: (714) 251 4537 REVISED (N) FLOOR PLAN SCALE: 1/4" = 1'-0" ELEC. BOX HEIGHT N.T.S. AGING-IN-PLACE NOTES A. REINFORCEMENT FOR GRAB BARS - AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH CRC R327.1. 1) REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. 2) REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER (1-1/2 INCH BY 7-1/4 INCH ACTUAL DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES AND 39-1/4 INCHES ABOVE THE FINISHED FLOOR, FLUSH WITH THE WALL FRAMING. 3) WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. 4) SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. 5) BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. 6) WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. 7) REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORY- INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. 8) SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. 9) BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION OF REINFORCEMENT SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. 10) REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETE SLAB FLOORS. B. DOCUMENTATION FOR GRAB BAR REINFORCEMENT - INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.4. (CRC R327.1.1.1) C. ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS - ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. (CRC R327.1.2). EXCEPTIONS: 1) DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROLS MOUNTED ON CEILING FANS AND CEILING LIGHTS; AND CONTROLS LOCATED ON APPLIANCES. 2) RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE ON A WALL SPACE WHERE THE DISTANCE BETWEEN THE FINISHED FLOOR AND A BUILT-IN FEATURE ABOVE THE FINISH FLOOR, SUCH AS A WINDOW, IS LESS THAN 15 INCHES. D. DOORBELL BUTTONS - DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 MM) MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. (CRC R327.1.4) WATER HEATER - DRYER - F.A.U. DOOR DETAIL N.T.S. SD LEGEND GFCI RECEPTACLE WR GFCI WEATHER RESISTANT RECEPTACLE TAMPER RESISTANT RECEPTACLE, 120V SINGLE PHASE, 20A, CONTROLLED BY ARC-FAULT CIRCUIT INTERRUPTER (AFCI) 240V DEDICATED OUTLET, AMPERAGE AS INDICATED IN PLAN CEILING-MOUNT RECESS LIGHT OUTDOOR WALL-MOUNT LIGHT FIXTURE W/ PHOTOCELL & MOTION SENSOR $LIGHT SWITCH WITH DIMMER (D) WHERE INDICATED $3 3-WAY LIGHT SWITCH WITH DIMMER (D) WHERE INDICATED $vs VACANCY SENSOR LIGHT SWITCH $W/D WASHER/DRYER DISCONNECT SWITCH, 20A, INSTALL PER MANU. SPECS. EXHAUST FAN (100 CFM MINIMUM) W/ HUMIDITY CONTROL IN-SINK DISPOSAL AIR REGISTER ON CEILING SMOKE DETECTOR CARBON MONOXIDE DETECTOR 4" DRYER VENT W/ DAMPER, TERMINATED 30" ABOVE F.F. ON OUTSIDE WALL 4" SMOOTH SURFACE VENT W/ APPROVED WALL STRAP, TERMINATED ABOVE ROOF THRU. APPROVED FLASHING, 14' LONG MAX., 2 ELBOWS MAX. W/H 240V-50 GAL. WATER HEATER TANK, RHEEMTM MODEL XE50T10H22U W CLOTHES WASHER D CLOTHES DRYER HOSE BIB WITH ANTI-SIPHON VALVE AIR RETURN ON CEILING ROOF-MOUNT ATTIC VENT IAQ FAN (PER TITLE 24), 80 CFM MINIMUM CO 18" 18" PER PLAN 100 SQ. IN. MIN. ON EACH LOUVER @ TOP AND BOTTOM 80" 15" MIN. 48" MAX. F.F. WINDOW SCHEDULE WINDOWS' U-FACTOR = 0.3 AND SHGC = 0.23 A 48"x48" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME B 60"x48" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME C 36"x36" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME D 36"x18" S.L. FROSTED GLASS W/D, DUAL GLAZING, VINYL FRAME, TEMPERED GLASS DOOR SCHEDULE OPAQUE DOORS' U-FACTOR = 0.2 1 30"x80" HOLLOW CORE DOOR 2 28"x80" HOLLOW CORE DOOR 3 36"x80" HOLLOW CORE DOOR 4 36"x80" SOLID CORE ENTRY DOOR W/ TEMPERED GLASS 5 48"x80" CLOSET SLIDING DOOR 6 24"x80" INTERIOR RATED DOOR 7 24"x80" EXTERIOR RATED DOOR DOORS 6 & 7 SHALL HAVE LOUVERS W/ DETAILS AS INDICATED HEREON OW N E R TT S T A R S L L C TE L : ( 7 1 4 ) 5 4 8 1 7 1 1 PR O J E C T A D D R E S S MA I N U N I T : 2 4 2 2 W M A R T Y L N JA D U : 2 4 2 2 W M A R T Y L N , U N I T 2 AD U : 2 4 2 2 W M A R T Y L N , U N I T 3 SA N T A A N A , C A 9 2 7 0 6 NE W A T T A C H E D 7 9 9 S F A D U AN D A T T A C H E D 4 3 1 S F J A D U 1. STC-49 AND 1-HOUR FIRE RATED WALL N.T.S. SOURCE: USG FIRE-RESISTANT ASSEMBLIES TEST NUMBER: UL U305 FOR DOUBLE WALL 5/8" SHEETROCK FIRECODE C CORE GYPSUM BOARD 1" AIR GAP 2x4 WOOD STUD @ 16" O.C. 2 LAYERS OF 5/8" SHEETROCK FIRECODE C CORE GYPSUM BOARD 2. STC-50 AND 1-HOUR FIRE RATED WALL N.T.S. SOURCE: USG FIRE-RESISTANT ASSEMBLIES TEST NUMBER: UL DES U327 AND BBN-760903 5/8" SHEETROCK FIRECODE C CORE GYPSUM BOARD 3" THERMAFIBER SAFB RC-1 CHANNEL OR EQUIVALENT ONE SIDE JOINTS FINISHED 2x4 WOOD STUD @ 16" OR 24" O.C. 5/8" SHEETROCK FIRECODE C CORE GYPSUM BOARD DATE 1/5/2026 SCOPE OF REVISION # 1 REVISE FLOOR PLAN TO CHANGE TO GAS RANGES, GAS CLOTHES DRYERS AND INSTANTANEOUS WATER HEATERS FOR BOTH ADU AND JADU RE V I S E D JA D U T I T L E 2 4 RE P O R T SHEET T1-R REVISION DATE BY 1 2 3 PROJECT ENGINEER BEN PHAN 10822 WOODWARD LN GARDEN GROVE, CA 92840 TEL: (714) 251 4537 OW N E R TT S T A R S L L C TE L : ( 7 1 4 ) 5 4 8 1 7 1 1 PR O J E C T A D D R E S S MA I N U N I T : 2 4 2 2 W M A R T Y L N JA D U : 2 4 2 2 W M A R T Y L N , U N I T 2 AD U : 2 4 2 2 W M A R T Y L N , U N I T 3 SA N T A A N A , C A 9 2 7 0 6 DATE 2/20/2025 NE W A T T A C H E D 7 9 9 S F A D U AN D A T T A C H E D 4 3 1 S F J A D U RE V I S E D AD U T I T L E 2 4 RE P O R T SHEET T2-R REVISION DATE BY 1 2 3 PROJECT ENGINEER BEN PHAN 10822 WOODWARD LN GARDEN GROVE, CA 92840 TEL: (714) 251 4537 OW N E R TT S T A R S L L C TE L : ( 7 1 4 ) 5 4 8 1 7 1 1 PR O J E C T A D D R E S S MA I N U N I T : 2 4 2 2 W M A R T Y L N JA D U : 2 4 2 2 W M A R T Y L N , U N I T 2 AD U : 2 4 2 2 W M A R T Y L N , U N I T 3 SA N T A A N A , C A 9 2 7 0 6 DATE 2/20/2025 NE W A T T A C H E D 7 9 9 S F A D U AN D A T T A C H E D 4 3 1 S F J A D U