Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
10181447_1408 N. MAIN - Plan (2)
Structural Technology Consultants Woman Owned \ Certified Small Business: P.roviding Practical Engineering Solutions Structural Calculations for WSS - SHOE STYLE SELECTION #36 1408 N Main Street, Santa Ana, CA STC Project No. 1120-190 June 3, 2014 111 2 111 No. C 75980 '| Exp: 060302014 ,1 *j '- 0/Ve,--r #1 7827 Convoy Court, Suite 406 1 San Diego, California 92111 (858) 278-2400 I (800) 681-8106 I FAX (858) 278-2424 I signengineer@stcsd.com I www.signengineer.com 9 OF THE SERVICE AND SHALL REMAIN THE PROPERTY OF:STC:WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED:OR NOT. THESE DRAWINGS AND Z STRUCTURAL TECHNOLOGY CONSULTANTS 7827 CONVOY COURT, SUITE 406,: SAN:DIEGO, CA:92111 PHONE NO.: 858.278.2400 FAX NO.:858.278.2424 N PROJECT: WSS-SHOE STYLE SELECTION #36, 1408 N, MAIN STREET, SANTA ANA, CA SHEET:1 OF 1 1 PROJ. NO.: 1120-190 DESIGNER: :VH DATE:06-03-14 j CLIENT: SAN PEDRO ELECTRIC SIGN COMPANY STRUCT. TYPE: BLADE SIGN QUANTITY: 1 F!.4 5 DESIGN CODE- CBC 2013 w/ ASCE 7 Provisions UNTTS; POUNDS, FT U.N.O U. E t] Z <CE to U Z 0 U G 0 0 Z r -1 ASCE 7-10 Wind Loads 29.4.1 F=ch*G*C/*As 29.3.2 qh = 0.00256*Kh*Kt*Kd*V' Kzt= 1.0 (unless unusuallandscape)Risk Category: II (Table 1.5-1) Kh= table 29.3-1 Exposure C 1<d- 0.85 (Table 26.6-1, for signs)I= 500 (constant: for: Lz, Table 26.9-1) V= 110 mph Fig. 26.5-lA e= 0.2 26.9.6 G-0.925 ((1+1.7*g,*Iz*Q)/51+1.7*g.,*Iz)) or 0,85 €=0.2 26.9-7 4=c*(33/z)(lio) z=max(0.6*h, zmin) zmin= 15 Load Combination Factor = 0.6 (Per 2.4110 9.- 3.4 g,= 3.4 Pdasign = 0,6 X (P) 26.9-8 Q=4( 1.0 / (1+0.63*(B+I)/Lz)0·63 ) 26.9-9 Lz- 19/33)e sign elem. #14, 411 G s/h B/S Cf, Pdesign 1 10 0.85 22.38 0.85 0.20 1.60 1.80 20.54 2 2 12.5 0.85 22.38 M LOADS: g SIGN AREA, A = 2.5' x 4.0' = 10 SQ-FT- WL = 10.0 SQ-FT x 20.54 PSF = 206 LB DL = 10.0 SQ-FT * 10.0 PSF = 100 LB Mwl = 206 LB x 2.0' = 412 LB-FT E Mdi = 100 LB x 2.0' = 200 LE-FT CE B 81 CHECK WALL CONNECTIONS: 0 g Tmax = [412 LB-FT x 12 IN/FT / (2 CONN. x 67 X 0 V = SRSS[(206 LB /4 CONN.) + (100 LB / 4 CO =I= USE 3/8" GALV. THRU-BOLT (A307) Tall = 2,475 LB, Vall = 1,320 LB OK 0 0.85 0.20 1.60 1.80 20.54 CHECK SUPPORT ARMS: USE ALUM. RT 2x2xl/4 S = 0.911 in:.3 Fbx = 412 LB-FT x, 12 IN-FT / (0.911 in? x 1 TUBE) = 5,427 P.SI fby = 200 LB-FT x 12 IN-Fr / (0.911 in·.4 1 TUBE) = 2,637 PSI fb(total) = 5,427 PSI + 2,637 PSI = 8,064 PSI Fb = 9,100 PSI QK 1 + [200 LB-FT- x 12 IN/FT/ (2 CONN) x 69 - 612 LB NN.)] = 57 LB / CONN <No. 875980 6| Exp. 06/3012014 /# * 1- 32/viL 3 CHECK MOUNTING PLATE: USE ALUM. PL 5/8x8 W & Tmax =612 LB 0 i M = 6122 LEI x 1.75" = 1,071 LB-IN E Seff = 3.5" (0:625'92 /6 -O.228 in.3 i fb = 1,071 LB-IN / 0.228 in.3 = 4,697 PSI 2 Fb = 11,800 PSI 915 r W g Cj th CC Z 0 6/3/2014 3:19:55 PM CHECK INNER ANGLE: USE STL L 2*2x3/16 Sx= 0.188 in., Sy = 0.188 In.3 Mwl = 412 LB-FT x12 IN/FT / 2 ANGLES =, 2,472 LB-IN MdI = [200 LB-FT x 12 IN/FT / 6"1[209 /4 = 2,000 LB-IN Fbx = 2,472 LB-IN / 0.188 in? = 13,149 PSI fby = 2,00OLE-IN / 0.188 in3 = 8,511 PSI tb(total) = 13,149 PSI + 8,511 PSI = 21,660 PSI Fb = 36,000 PSI / 1.67 = 21,557 PSI < 1% OVERSTRESS QK VOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF SCANNEp COPIEC STRUCTURAL TECHNOLOGY CONSULTANTS OR ITS OFFICERS OR AGENTS SHALL i ES OF PLAN SHEET !' DESIGN CRITERIA: CODE:2013 CBC WIND:BASIC WIND SPEED: 110 MPH (3 SEC. GUST), EXPOSURE: C, RISK CAT.: II SEE WIND CALCULATIONS FOR DESIGN WIND PRESSURES LOADS:DL: 10 PSF, LL: 0 PSF, SL: 0 PSF STRUCTU RAL TECHNOLOGY CONSULTANTS 7827 CONVOY COURT, SUITE 406, SAN DIEGO, CA 92111 PHONE NO.: 858.278.2400 FAX NO.:858.278.2424 PROJECT: WSS - SHOE STYLE SELECTION #36, 1408 N. MAIN STREET, SANTA ANA, CA SHEET:1 OF 1 PROJ. NO,: 1120-190 DESIGNER: VH DATE:06-03-14 CLIENT:SAN PEDRO ELECTRIC SIGN COMPANY STRUCIT. TYPE: BLADE SIGN QUANTITY: 1 EE CONTRACTOR'S RESPONSIBILITY: THE CONTRACTOR SHALL FIELD VERIFY THAT EXISTING AND PROPOSED SITE CONDITIONS ARE CONSISTENT WITH THESE DRAWINGS PRIOR TO THE START OF ANY WORK. NOTIFY ENGINEER OF RECORD IMMEDIATELY IF SITE CONDITIONS VARY FROM THESE DRAWINGS. CONTRACTOR (INSTALLER) IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION AND JOBSITE SAFETY. SCOPE OF WORK: THE SCOPE OF STC'S DESIGN IS LIMITED TO MOUNTING PLATE, ANCHORAGE, SUPPORT ARM, AND ArrACHMENT OF SIGN CABINET TO SUPPORT ARM. ALL OTHER rTEMS ARE EXCLUDED, INCLUDING, BUT NOT LIMITED TO SIGN CABINET FRAMING, AND EXISTING WALL STRUCTURE AND ITS CAPACITIES, ANY MODIFICATIONS TO STC'S DESIGN SHALL BE REVIEWED AND APPROVED BY A LICENSED ENGINEER. STRUCTURAL TECHNOLOGY CONSULTANTS (STC) DESIGN IS BASED ON DRAWINGS AND DIMENSIONS PROVIDED TO STC BY OTHERS. THE MANUFACTURER AND INSTALLER SHALL VERIFY ALL FINAL DIMENSIONS AS SHOWN ON THE ENGINEERING DRAWINGS AND THE SHOP DRAWINGS, AND SHALL BE RESPONSIBLE TO ENSURE THE FIT OF ALL COMPONENTS. GENERAL NOTES: 1. ALUMINUM: GRADE 6061-T6 (Fty=35 KSI MIN.). 2. ROLLED STEEL / PLATE STEEL: ASTM A36 (Fy=36 KSI MIN.). 3. NUTS AND WASHERS SHALL BE USED WITH ALL FASTENERS AND SHALL BE COMPATIBLE WITH FASTENER SIZES, MATERIAL TYPES, AND HOLE SIZES, IN ACCORDANCE WITH AISC SPECIFICATIONS, UNLESS NOTED OTHERWISE. 4. THE MATERIAL/COATING TYPE USED FOR THE CORROSION RESISTANCE OF FASTENERS SHALL BE BASED ON EXPOSURE CONDITIONS AND THE RECOMMENDATIONS SET FORTH BY AISC, IN ACCORDANCE WITH COMMON INDUSTRY PRACTICE. NO GUARANTEE TO PREVENT CORROSION THROUGHOUT THE LIFE OF A STRUCTURE IS IMPLIED. FASTENERS SHALL BE MONITORED PERIODICALLY FOR SIGNS OF DETERIORATION. 5. LAG SCREWS: ASTM A307 (Fu=58 KSI MIN.). INSTALLATION PER 2005 NDS. 6. THREADED RODS: ASTM A307 (Fu=58 KSI MIN.). 7. ALUMINUM WELDING: ALL WELDING SHALL BE PERFORMED BY AWS QUALIFIED WELDERS USING AWS APPROVED SYSTEMS AND PROCEDURES, IN ACCORDANCE WITH AWS Dl.2/Dl.2M: 2008 STRUCTURAL WELDING CODE - ALUMINUM. 8. ALL FABRICATION SHALL OCCUR IN THE SHOP OF AN APPROVED FABRICATOR, AS DESIGNATED BY THE LOCAL BUILDING DEPARTMENT. 9. PROVIDE A PROTECTIVE COATING TO MINIMIZE CORROSION FOR ALL STEEL MEMBERS EXPOSED TO WEATHER, MOISTURE, OR SOIL. 10. PROVIDE ISOLATION OF DISSIMILAR MATERIALS INCLUDING A PROTECTIVE COATING FOR ALL ALUMINUM TO BE IN CONTACT WITH STEEL OR CONCRETE. (EXAMPLE: NEOPRENE BARRIER, PLASTIC WASHER, ZINC COATING, OR SIMILAR.) 11. IT IS THE RESPONSIBILITY OF THE OWNER OR OWNER'S REPRESENTATIVE TO MONITOR STRUCTURAL ELEMENTS AND FASTENERS FOR DAMAGE, CORROSION, OR DETERIORATION. 6/4/2014 9:04:40 AM 4'-0" 15'-0" __-1 MAX. LD A (2)-CONTINUOUS 1 STL. L 2"x2"x3/16" STRINGER BEHIND WALL TO SPAN (16" MAX.) 1_j \ N OVER TWO STUDS ALUM RT 2"x2")24"Al, W/ (2)-1/4" WOOD 1 SCREWS W/ 1-1/2" MIN. PEN.- EXISTING WOOD INTO STUD STUD WALL m ELEVATION @ 16" O.C.| SCALE: ITS. P. .-1 TYPICAL SADDLE )ETAIL j| SCALE: ITS. .XJi.hv- ALUM. PL 5/8"x8"x8" W/ (4)-3/8"0 THRU-BOLTS A,SE'3.E DETAIL </A°4% ap. 06/30/2014*No.075980 =111m »f OF CAL\0>' 1 r, -b 3 9 8" TYP. 6" 11 /3/16 v \ TYP. 1 [) 1 -/1/16 3/lb ' 20 6 STRUCTURAL TECHNOLOGY CON5UL I AN I b UK lib Urrlltle UK ABIC 13 Ir,ALL INI I Dc Ic/ruly/1{kc f un I rl' ....r./.1 W. .VI·,1 ..1 .ii.-·.w wi -Il-li••••-•- -V. Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana. org ELECTRICAL SIGN REQUIREMENTS Code references are to the 2010 California Electrical Code (CEC) All signs require Planning Department approval. All electrical signs require electric plancheck and permit. 1. Manufacturer's instructions are required at the time of submittal C-11: 3-21-2011 2. Submit detailed installation instructions including diagrams to the Building Department for plan review at the time of submittal. Plans must include appropriate items noted by this bulletin. 3. Cash or surety bond in the amount of $200,00 is required at time of issuance for each address. The cash or surety bond will be refunded after all required finals. A building permit is also required - except for open or highlight neon lighting. Installation Requirements: CONTACT FIELD INSPECTOR PRIOR TO SIGN INSTALLATION. (SEE SECTION G OF THIS BULLETIN) 1. Conductors and equipment shall comply with California Electric Code Article 600. 2. All metal parts of a sign Shall be bonded in the manner specified in Article 250. Isolated metal parts are permitted to be bonded by using an external green insulated conductor. Equipment grounding & bonding conductors must be sized by 110.26 and protected from physical damage. Minimum size is 14 AWG. CEC 600.7 3. A listed disconnect switch in the power supply primary, shall be installed within sight of sign or have permanently installed means for locking in an "OFF" position. This is also true for a transformer enclosure. CEC 600.6 4. A listed receptacle or an approved termination device shall be used for each neon electrode. To relieve stress at terminations, tubing shall be supported with listed tube supports in an approved manner within six inches of electrode connection. CEC 600.41 & 600.42 5. Every electric sign of any type shall be listed by an approved testing laboratory and shall be installed in conformance; with this listing. That includes "l of x", "2 of x" labeling for each separate unit of a multi-unit sign. CEC 600.3 6. All "can" letters and transformers housings shall have section labels that are readily visible after installation. CEC 600.4 7. Transformers shall be located where accessible and be securely fastened in place. Page 1 of 2 O 0 m » When not inside the sign, they need a 3 foot high x 3 foot wide x 3 foot deep workspace. Transformers are permitted to be located in attics or canopies provided there is a passageway at least 3 feet high x 2 feet wide with a minimum 12 inch catwalk/walkway from the point of entry. Transformers must be securely fastened and independent of T- bar when above a suspended ceiling. No part of sign may be fed with flexible cord when located above T-bar ceilings. CEC 600.21(E&F) & 400.8 8. Adequate illumination shall be provided for all working spaces about electrical equipment. This applies to attics and canopies when entry is required to service or inspect the equipment. At least one switch is required at entrance. CEC 110.34 & 600.21 9. Doorway to an attic or canopy space shall be minimum 3 feet by 2 feet wide. CEC 600.21(E) E. Open neon outline or highlight lighting. 1. To be treated as a sign by this department. However, Section D-5 & D-6 of this bulletin will not apply. 2. Neon tubing shall be located where not normally exposed to physical damage. Open neon tubing below 9 feet shall be protected from physical damage by an approved shielding method. CEC 600.30 and 110.34(E) F. Light-Emitting Diode (LED) Signs 1. Will be treated as a sign by this department. All sign rules in sections A, B, C., D, F, and G will apply as appropriate. 2. LED illumination for signage must be a listed or recognized component. Many LED manufacturers specify particular brands and models of transformers some do not. Manufacturer information to clarify this issue is required on LED sign plans. 3. Unlisted LEDs may not be used in an electrical sign of as permanently installed illumination. 110.3 4. Please have packagihg or catalog cut-sheets on hand for inspector to review when LED modules do not bear listing symbols. G. Inspections 1. Contact an Electrical Inspector one (1) workday (minimum) in advance of installation to arrange a site meeting on day of installation. 2. Call for inspection Monday through Friday, 8:00- 8:30 a. m. at (714) 647-5821. Approved prints and the job card must be on site for inspection. Page 2 of 2 ,i \L-tog Y.4 V\Cti Ch r.t--3, LED Module JE-004CW-15 Specification *ka«RCAPFIE„329 ,/* //E'*19R/F'1'/N*'Flap/dNEJ-M##34#92CU**»Utt2 51*BEL r i,,e/44,*4/////4/4/-'4-A--'4·344/.-*e-*0.¥1,2*1- Description Viewing Angle Part Number Color LED Size Protection Class 281/2 JE-004CW-15 Cool White 2835 IP 65 120° + 5 Dimensions 0.38 r 11 5 18: 5 _ I UJ ·10.·5. I 03.8,.90 |. Ma L ' 16.:0; 'I 50 i .2 rflm' 424 G·n' .4*41*k - 425*57(012= 1 -4.9 11 Length Width Height LEDs per Modules module per foot Packaging 50mm 13.5mm 4.9mm 3 2 50 pcs X 2 folls = 100 Module Per Bag 22.63 Feet x 2 rolls = 45.26feet Notes: 1. All dimensions are in millimeters. 2. Tolerance is 10.25 unless otherwise noted. 3. Lead spacing is measured where the lead emerge package. 4. Specifications are subject to change without notice. Electrical / Optical characteristics at TA=25°C Parameter Typ.Max.Units Color temperature 7500 8500 K Luminous flux 55 65 LM Forward voltage 12 12.2 V Forward current 58 62 mA Power consumption 696 756 mw Operating temperature -25°C To +7890 I.1 9'-6" WSS Length . 6'-0"adcias WSS Logo APPROVED PLAE·44% 2 DIVISION MASTER I.D. LO-I.94=11-UELE- G. P.___6-(__ Zonel-EL-1_ PLANNER_A-9-1_f DAR4612/1.9 RANSFERRi=n :10 ..1.LANNiNG INOPF-:"'..-L 3 #·Ug ME·Juirc?£.'4.-1 ROUGH____ FINAL A,t-i k.·14"t -Shoes. Style. Selection. ile Selection 4 prf%· NAME ;71 i'30" C - .RETAJH PLAN' t • C SUBJECT TOil BELOW:0 0 INTEr. 1 - E O ALL >·6O 6?0 0 - 9 SUEAd· 0 SORE. 0 p 9.* L. I. U. 8 '9.' DNS. ' ' O-,2 0 , -'- , ···C CONDITIONS 04' - 2.,02. i :CATIONS 0 S D,:6 :iNG ANS 7.4- 11-1.-413 €IGN -10,4 -Lt 1 SIGNAGE NOT TO 1elPROJECT ABOVE 1 EXISTING BUILDINS WALL 4.33 SQ. FT.3.50 SQ. FT.11.17 SQ. FT.28.00 SQ. FT.19.00 SQ. FT.8 4 ri „ 120'-0" 1 2 t ,, COnVERSE Reebok 'SS 20'-0" Shoes. Style. Selection. A 0 e North Elevation Building Facing to Parking Area & Main Street: INTERNALLY-ILLUMINATED SINGLE FACED LOGO & REVERSE CHANNEL LETTERS & PROJECTION SIGN -TAGUNE· SIGN AMEA17.60 so. FT Bilt riloposit) i SIGN AREA 1 60.46 so. 17.- SCALE: 1/4" = 1'-0" Photo rendition for representational purposes only. Photo scales are close approximate. Actual sign may appear larger or smaller than shown. Colors shown may vary due to ink jet printing interpretations. Revisions WSS - SHOE STYLE SELECTION #36 €l€{ Nalure G' 9€: -C- SIGN COMPANV 1408 N Main Street Santa Ana, CA Wilm,™glon Cokillr.907,- -3.- 0 6'1.' 8. S .1 4/· b i Gus Navarro Sr. Ay 05-15-14 GN 1 of 8 310-344-4661 office 4 C '•cme, A./c.4 Dar·] Drawing Numbef 11(I-144-1882 f.n 14-03-7272 65'-0" Building Frontage 1 Shoes. Style. Selection. 20'-0" |30" f 1 10'-0" Bottom of Sign to Grade f PROJECT AIOVE EXISTING IUILDING WALL WES LOGO SIGN AREA 34.46 so FT "TAGLINE" SIGN AREA 15.26 so Fr TOTAL. PROPOSTID SIC:N AREA 49.72 so. FT 8'-4" WSS Length 14'-1" Shoe Style Selection Length 5 . 1 1 1 1 ; 11 1 1 1 1 15'-6" Logo P £ 41 4k Shoes. Style. Selection. S 13 SUOISIABI 0U East Elevation Building: INTERNALLY-ILLUMINATED SINGLE FACED LOGO & REVERSE CHANNEL LETTERS FACING TO MAIN STREET ' SCALE: 3/8" = 1'.or ) Photo rendition for representational purposes only. Photo scales are close approximate. Actual sign may appear larger or smaller than shown. Colors shown may vary due to ink jet printing interpretations. 1 yle'lf¥. .. .: 65'-0" Building Frontage existing existing air conditioning ducts air conditioning ductsds- . Shoes. Style. Selection. ·0"20'· WSS LOGO SIGN AMEA 1 TAGUNE· SIGN AREA ',1 TO, Al [94(31'K}St 1, U :.4, N AIRE. A34.46 so.. ; 7.63 se. n , 1 42.09 so. ir. 10'-2" Shoe Style Selection Length -.--/*.I-- 1 . 8'-4" WSS Length 1- b [ SIONABENOTTO PROJECT ABOVE 1 EXISTIN, mUILDING WALL 9. V Shoes. Style. Selection. West Elevation Building Facing Parking Area & Sycamore Street Entrance: INTERNALLY-ILLUMINATED SINGLE FACED LOGO & REVERSE CHANNEL LETTERS ,, SCALE: 3/16" == 1'-0 Photo rendition for representational purposes only. Photo scales are close approximate. Actual sign may appear larger or smaller than shown. Colors shown may vary due to ink jet printing interpretations... SAN PEDRO Revisions WSS - SHOE STYLE SELECTION #36 €l€CTRIC Nave of Am /7 SIGN COMPANV 1408 N Main Street Santa Ana. CA 77 Lolne A.Inue *#'glor. Calom,0,0744 D.t C·3Ar' 83, 1 9. ce: Nui'*0 Gus Navarro Sr. - 05-15-14 GN 3 of 8 310.344-4661 offiu· 2-stome- Aspe.al r.'. Dia/ng N„ btr· 310-149-8882 f.1 14-03-7272 5'-6" WSS Logo 1 WSS LOGO SION A 42.86 sa. SIGN SPECIFICATIONS: ITEM DESCRIPTION Sign Face White Aluminum Face Background Background Cabinet 6" Deep Fabrication WSS Channel Letters 5" Deep Dual View Outer Border 5" Deep Dual View Illumination L. E. D. / Neon Illumination <>"SHOES. ST¥LE. SELECTION." REVERSE CHANNEL LE. |TEM DESCRIPTION Reverse Foce Channel Letters Returns Illumination 55: 15'-1" Shoe Style Selection 9'-6" WSS LOGO LENGTH 21 L 17.60 so. Fr 60.46 so pr 1 1 -TAOUNE-SIGN AREA rOTA, PnoposED Y BION:Al/PA 1 1 SPECIFICATION w #301 Red Painted 1 st Surface #121 Silver Translucent Vinyl, Applied 1 st Surface Paint Brushed Aluminum Finish White & Grey Applied Translucent Vinyl Grey Applied Translucent Vinyl j 7200k Designer Bright White r 1 SPECIFICATION Aluminum, Painted WSS Blue PMS 2746 2" Deep, Aluminum, Paint WSS Blue PMS 2746 White L.E.D. j White Aluminum ' Background 5" Deep 5" Deep Dual View Outer Grey WSS Dual View Channel Channel Letter Letters SIDE VIEW Duot/Vicv., WSS Channel UNIers wilh Outer Grey Boide, on Aluminum Bockgiound iwumnda 13" 65· #8 X 30' Tek kiewl 1 +. -= 1 3* Deep WhileAluminum Rolums | . Alum,mi n Backgro:mol¥-11 /Wilh Nylon An{hof , ' -- •Trini CapEmbe[Ided Inlo Nk-_-- N. Tubing, Stuao Fosell Aluminum Fate b ;Min. (4) Per lelle,.-«.,14 With 6" Stand- 01 4 1=li 3/8" Thru Boltdit Clear Acrylic Backingt..E.D. Module tf. Allorhed Iniide T-4. - Clear Acrylic BackingRovers,i Chon,ml Laller 07--- 1 - LED. Power Supply L =IN ' - -Noon Glass Sland Clear i , Polywrbong,0 P -!4" Con,luil ," riA - • Acalic Face wilh4*1_# tt r #-«>Tianslucent Vinyl Buck „ .- „Dise,ined Swildi '1G + Neon TubingUal Ld 4 ; snue: Mom,Noon Tubing : Tran=lamid,itox to ConiallEd iling N • An 3/Ir· Thru BollBuilding Fos,in g PRIMARY ELECTRICAL JUNCTION [ , co,2 Diatn t·toles,BOX BY OTHERS ,L - MInimum 2 Pei Leller591/ 11} 20 AMP CIRCUIT @ 1 Drain Holes.UNDERWRITERS 2 1 120 VOLTS 1 4 Minimum 2 Pei Lotte, ..UNDIR.,1/841 LABORATORIES f-LOCATED BEHIND FASCIA WALL i 'L - 1!4" Spacers ium'·' 12•99'83'14us.6 - -:'· ELECTRIC SIGN CENTERED BEHIND SIGN ("IN f'l ' DUAL-VIEW CHANNEL LETTERS on BACKERSECTION DETAIl: LE.D. -ILLUMINATED REVERSE CHANNEL LETTERS SECTION DETAIL - NTS PAINT and VINYLCOLOR SCHEDULE 6'-0" WSS LOGO .r 14 Shoes. Style. Selection. NORTH BUILDING ELEVATION: WSS "Dual-View" SIGN SPECIFICATIONS FOR SINGLE FACE CHANNEL LETTER SIGNAGE 'LAR.i)Od 075023 r Photo rendition for representational purposes only. Photo scales are close approximate. Actual sign may appear larger or smaller than shown. Colors shown may vary due to ink jet printing interpretati SAN PEDRO Revisions Job#ama WSS - SHOE STYLE SELECTION #36 El€(TAIC No. Dme By Nature oi Revision AS/123£ SIGN COMPANY 1 1408 N Main Street Santa Ana, CA 701 leme Aanue WR.4./ClhforNO ION, 2 5aSpe,zer, 1 02!aGus Navarro Sr. 05-15-14 1 Drawn By Sheel Numbm GN 3 1 4 of 8 3 10-549-4661 office £/*s* Aggr- DMO a Diawing Numb# 310-549-8882 fax 1 14-03-7272 THGIS AN 0916+NAL. UNNEUSHED CRANUIG GR.1.2180 81 SAN nECROSIP• COMFAN¥ 11 1545UllinlkOSC B ·I'DUR DEBECIAL USE U; COPINECT*N A/H • PROJECT 82iNG PLANNED} FO»02 0, 971 PEDRO %& 00.*PANY F 15 NO- 10 82 5HOWN 'ID AN¥©NE OUUSIDE VOUM < aSANIZATH;N No n 15,r 70 6. USED, FEPRODUCED. COPED 0,; EXMBIFTEE}dN AwN FAS?*UN 8'-4" WSS Length + 1411" Shoe Style Selection Length E -e2,- 9 Shoes Style. Selecti 5'-6" WSS Logo co f O EDI I .9 0CO ro hI2e Z (0 13"%185-9*Z*l 7*GL.INE" SIGN,AREA 4mm3 15.26 sg. FA 1 WSS LOGO SIGN AFEA l i34.46 sa. p-r. T%'fgsED 0-49.7-2.99:EL 1 SIGN SPECIFICATIONS: ITEM DESCRIPTION SPECIFICATION Sign Face White Aluminum Face #301 Red Painted 1 st Surface Background Background #121 Silver Translucent Vinyl, Applied 1st Surface Cabinet 6" Deep Fabrication Paint Brushed Aluminum Finish WSS Channel Letters 5" Deep Dual View Willie & Grey Applied Translucent Vinyl Outer Border 5" Deep Dual View Grey Applied Translucent Vinyl Illumination L. E. D. / Neon Illumination 7200k Designer Bright White SHOES. STYLE. bELE •*i {•12-:104:Ri:ill:LYMN=-14:ke, ITEM DESCRIPTION SPECIFICATION Reverse Face Aluminum, Painted WSS Blue PMS 2746 Channel Letters Returns 2" Deep, Aluminum, Paint WSS Blue PMS 2746 Illumination White L.E.D. £%WIZ Aluminum Relum _ 1 Aluminum Face· -- b LE.D. Module q Attached tnslde Reveise Clionnol Letler lear- Pol,quibegate B.ik Ext,·ting Building Fai,in r 7, , UNDERWRITERS 151 /1==011,9. ELECTRIC SIGN 2" , li. 114"5!and·oil 1 - #8 X 3" Tek kiews Willi 141on Anchal - Embedded Into SIU{,O Fas[to MIn. 14) Per lellor With 1*"51.ad-offi - I.E.D. Power Sup,4 - r Conduil Dinonned fwitih PRIMARYELECTRICAL JUNCTION BOX BY OTHERS W/ (11 20 MAP CIRCUIT @ 120 VOLIS LOCATED BEHIND FAXIA WALL CENTERED BEHIND SI6N Blf» C 1 1: White Aluminum > a: 1Background ,cC I I e · ii Nju-4 r Oeep Wmt. i g' 11 -Aluminum Backg,ound 1. 1 1 .--7 -1 -C 0M#'-- Neon Tubing .3/8" Thru 80!1 EC I ,-- Clea, Ac,yllc Backing - Clear Acrylle Backing -7 -Neon Glass Stand iSwllch / J 1r-F-h - •-Airly'k Faca with 1- 1 1.....9.- .-2 5" Deep Outer Grey Translucont Vinyl ,£ Deep -- » Neon Tubing 1 Dual View Dual View &Slice! Mclal -Nean Tubing r 4- WSS Channelr-IM:mored, te Com all N-Channel Letter IAll ' -3/8- Thru Bill LettersElact:irml Conipener,1. i Dmin Holes. - Minimum 2 Per Latter _ 6- - M um 2 Per Letter UNB#IMS1,44-4L- , _ - 1 Vt SpleerE . . DUAL,VIEW CHANNEL LETTERS on BACKER l . -J1 -SIDE VIEWSECTION DETAIL: L.E.D. -ILLUMINATED REVERSE CHANNEL LETTERS I SECTION DETAIL - NTS . Dual/View WSS Channel Letters with Outer Grey Border on Aluminum Background EAST BUILDING ELEVATION: WSS "Dual-View" SIGN SPECIFICATIONS FOR SINGLE FACE CHANNEL LETTER SIGNAGE Photo rendition for representational purposes only. Photo scales are close approximate. Actual sign may appear larger or smaller than shown. Colors shown may vary due to ink jet printing interpretati O,5305 98#VO 'Euy Blues 8 JO 9 'OquIN leo iumbar 11} 115 15 * GRONA L U:47·081.12'ED 01'A'v. NG en G ;ED 6, SAN PEDRO SIGN Mll'AN¥ 11 IS SUBWI! 11.0 $1. A :¥01.111 PEGSJNAL USE »,1 00>INECIKON WllH A PROJI.C! UaING FLANNED ;OR YOU IW 5 / P EDRO SIGN GCN,IPAN¥ R 13 *105 10 86 9,01,11 10 /¥ONE OU SIDE ¥OU R OBCANIW ION NOR [5 J] TO 115 USE)_0121'90:>UGED, COPED 01; EXH]EIFTED 18 AN¥ FASAW N -- - 10'-2" Shoe Style Selection I White Aluminum4 .1 - i i Background 1 1 8'-4" WSS LOGO LENGTH 1 J 11 5'-6 WSS ' LOGO 1 50 Deep 5" Deep Dual View Outer Grey WSS Dual View Channel Channel Letter Letters - SIDE VIEW Dual/View WSS Channel Lelters with Outer Grey Border on Aluminum Background 9- --*4: W58 LOBO SIGN/AREA i 34.46 sa. rr I 9-AGLINE-'SIGN AREA 7.63 sa. rr fTSED !942709 591 FT. 3 SIGN SPECIFICATIONS: W.4>·wss"LOGO , ------77'"71 ,O C 2" r l'h"Stand-oil ,91 +- ITEM DESCRIPTION SPECIFICATION - 1. 2 #8 X y Tek Screws 1 1 3" Deep White gAluminum Returns- 1 1 With Nylon Anchor --4 - Trim Cap=ALL =-a -- Neon Tubing Embedded Into • Aluminum Background , CO Sign Face White Aluminum Face #301 Red Painted 1 sl Sorlace ,;-3|' - b/r Thru Boll Stuico FosciaBackgroundBackground#121 Silver Translucent Vinyl, Applied 1 st Surface Aluminum Face - 'Min. (4) Per toller } Wilh IM"Sland-olls 'LF - Clear Acrylic BackingCabinet6"Deep Fabrication Paint Brushed Aluminum Finish i I -L.E.D. Module -=- +. Allothed Inside ---- - Clear Acrylic BackingWSS Channel Letters 5" Deep Dual View White & Grey Applied Translucent Vinyl Reverse Channel Letter j •--LE.D. Power Supply Swiloh . f Discemile' 7 = ·•-Neon Glass Stand F- 6(100/ D Transtuoent Vinyl Outer Border 5" Deep Dual View Grey Applied Translucent Vinyl --Aciylic Face withPoly,o,bongle :kik k -Disionned Switch -Neon Tubing- 1 ComiduitIlluminationL. E. D./ Neon Illumination 7200k Designer Bright White .R. j Sl,Bet Melal .4, ·- - Noon Tubing3 3 - Li 1 Tons!O*nle,Box to ConwIn ag- 3/8" Thru Boll4*4"SHOES. STYLE.SELECTION."' REVERSE CHANNEL LETTER ,-to»t .... ,Exhling- 0 All Building Fositu [a Elockical £ •v |TEM DESCRIPTION SPECIFICATION PRIMARYELEaRICALJUNCTION Compone,)10 ·=i7 Drain Holes.1,1 BOX BY OTHERS L -- -- Minimum 2 Per LetterW/(1)20 AMP CIRCUIT@ReverseFaceAluminum, Painted WSS Blue PMS 2746 i I 20 VOLTS 1 Drain Holes../., UNDERWRITERS u L - Minimum 2 Per Letter ,& ,&645:'al @Channel Letters '4 LABORATORI,E,j® L j- -LOCATED BEHIND FASCIA WAIL ' 1 M' Spacers puslo] CReturns2"Deep, Aluminum, Paint WSS Blue PMS 2746 ELECTRCSION CENTERED BEHIND SIGN -o c - 28IlluminationWhite LED.DUAL-VIEW CHANNEL LETTERS on BACKER eXE SEtTION DETAIL; LEA 4LLUMINATED REVERSE* CHANNEL LETTERST SECOON DETAIL - NTS ZE. - 1 1 W 4! d WEST BUILDING ELEVATION: WSS "Dual-View" SIGN SPECIFICATIONS FOR SINGLE FACE CHANNEL LETTER SIGNAGE Photo rendition for representational purposes only. Photo scales are close approximate. Actual sign may appear larger or smaller than shown. Colors shown may vary due to ink jet printing interpretati I_Shoes. Style. Selection. . 1 1 - 2'-2" 24 Typical 140-0"1'-9" ' 1 . - 4 1 7 1 1 C *nVERSE , f I I acitck,s' AIR JORDAN ' 4.33 SQ. FT.3.50 SQ. FT.28.0 SQ. FT. 1 5'-7"9'.6" 1 114 I < 1 1 1 , / 1 24" Typical Reebok 11.17 SQ. FT. 19.00 SQ. FT. 48 30" d 1.-- ' 1 1 2//:91 1 8-$2_--_ ___ „Shoes. Style. Sele?tion.- -ttiji- Building WallDouble Face Projecting Sign 1 Brushed Aluminum Finish on WSS Logo Embellishment BUILDING WALL SIGNAGE: TYPICAL NON-ILLUMINATED WALL SHOE LOGO BRAND NAMES - FOOTWEAR NAME BRAND & PROJECTING SIGN SPECIFICATIONS .Scale: 1/2" = 1'-0"L==D Photo rendition for representational purposes only. Photo scales are close approximate. Actual sign may appear larger or smaller than shown. Colors shown may vary due to ink jet printing interpretations. . 96% CO .. % ... 4 W 120'-0" Building Length 1-,4.-141 S .1 D C r>l f # 799, 4 A Building Width e SITE PLAN / BUILDING SIGN LOCATIONS . SCALE: Not To Scale Photo rendition for representational purposes only. Photo scales are close approximate. Actual sign may appear larger or smaller than shown. Colors shown may vary due to ink jet printing interpretations. Z4 65'-0" SAN PEDRO Revisions €l€(TRIC WSS - SHOE STYLE SELECTION #36 No Date By Nature 01 Revision SION COMPANV A.'dr. S 1 1408 N Main Street Santa Ana. CA 701 Loune AqiveL/-,A W,.gle. CoIHom,0 907JI S:Uusporu* i 1 Date Dia./1 -·. 5·ret Wi,ibig Gus Navarro Sr. 05-05-14 1 GN 8 of 8 110-544-461.1 office 4 " iN-,e Alip· IA·11 I kati· £4.Mng Ncr ce· 110-34•1-81tlW fax 5 14-03-7272 I ·· ' I- 44'L-, I '4 tD,I,2,1 'OUE U.EU GEI'ADD. ar! 00'CD y 0-91--ED . ANr • 7- ' 9 1 CU / IH liot N - MAIN t=>t . 0 It 1947 10 1 5-39 1- c ;sl 8180 'Ide#OV 5 Cl g =-CD 0,0 -0 tanceol this plan an spciti DEW -1 FO=--Er -¢20,0 M O m = 0 0 40@Nes Jamm 1 3 0 :.9 CD .... 91 f M 2023291- & 2 037 63 252 =M 2 9 9 61 *9M m g O Mm EM XE© 4-211,5*SE 93.= ai e M7/53*9 59/Cm g q 87 09 00031 a 0 91 91 Do = O 05 SM 2 k 1.-7*# 0 -6 C m Ex =r 5 9 0.-- i 8-mi wCO 3 N U, 0 0 S. n .1 3 2 wam <35 9* R0, 31-0 aL--O €13 3 r 2 3-3 6=/ 0022 083%X C m® 0 -,gy -1 3 3 'DEC 0 59 5 03 a. ..70 5aeO0 21.-Oco eq<€240 -RON 2.-il/ /A 0 -·gogi J 02.2 c Ev =1 E .//E - m m R 7. 5 10 0 810 Eq 003- 5- m e.m g. 8-2.2,3 1 »=21 Z m € .9 6 2.9 1/ -0 -2 g8 7 w '1 2 E -0 M m c W aw0 0 0 1 -m - # -2.6- r /24I. /7 13934 1 e M BNOZ 00013 NOIJ:103 3000 CONSTR. TYPE OCC. GROUP 0,0,00 0; &r n W ) sheet metal screws)n center, 2 1 1 LA Z\+ Nf