HomeMy WebLinkAbout423 E Pine St & Unit E - PlanOWNER PROJECT TEAM MARTIN Z HERNANDEZ 83516 MECCA HILLS AVENUE COACHELLA, CA 92236 P: 657-230-1552 ARCHITECT VICTOR FRESSIE DIALECTIC ARCHITECTURE 1111 S. GRAND AVE, SUITE 712 LOS ANGELES, CA 90015 P: 626.375.2873 STRUCTURAL ENGINEER FRANCISCO GARCIA FJ ENGINEERING & DESIGN 600 W. MAIN STREET, SUITE 207 ALHAMBRA, CA 91801 P: 626.548.3874 PROJECT INFORMATION PROJECT ADDRESS: 423 E PINE ST & 426 PINE ST. UNIT #E , SANTA ANA, CA 92701 LEGAL DESCRIPTION: APN: 40408612. PORTER, SPURGEON & BLEES ADD BLK E LOT 11 AND 12 -EX- W 43FT OF LOT 11 TR 568 PROJECT DESCRIPTION: CONVERTING THREE ATTACHED GARAGES INTO 617.00 SF ACCESSORY DWELLING UNIT WITH TWO BEDROOMS AND ONE BATHROOM. REPLACING ALL EXISTING WINDOW ON MULTIFAMILY BUILDING WITH "LIKE / AS" REPLACEMENTS. ZONE:R3 OCCUPANCY:R2/U CONSTRUCTION TYPE:TYPE VB SPRINKLERED:NO FIRE SPRINKLERS REQUIRED PER CA GOVERNMENT CODE 65852.2(e)(3) HEIGHT:(E) 23' - 10 1/2" - NO CHANGE IN HEIGHT USE:APARTMENTS FEMA FLOOD ZONE:ZONE X APPLICABLE CODES: 2022 CALIFORNIA RESIDENTIAL BUILDING CODE (CRC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBS) 2022 CALIFORNIA ENERGY CODE (CEnC) 2022 CALIFORNIA FIRE CODE (CFC) CITY OF SANTA ANA MUNICIPAL CODE VICINITY MAPFLOOR AREA CALCULATIONS PER CITY OF SANTA ANA: LOT AREA: (E) BUILDING 1 (N) ATTACHED ADU (E) ADU TOTAL HABITABLE AREA LOT COVERAGE: (E) BUILDING 1 (E) ADU TOTAL HABITABLE AREA 3,313.00 / 7,370.00 X 100 = 44.95% PARKS AND REC DEVELOPMENT FEE CALULATION 617 / 4,077 = 15.14% THIS RRATIO IS ONLY FOR PARKS AND REC USE ONLY. 7,370.00 4,077.00 617.00 630.00 4,707.00 2,683.00 630.00 3,313.00 SYMBOLS LEGEND N Room name 101 1 A101 1 A101 SIM _____________ A101 1 Ref 1Re f 1 Ref 1Re f 1i 101 1i 1 NORTH ARROW 1 0 SCALE ROOM TAG ELEVATION NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER A101 1 SIM INTERIOR ELEVATION CALLOUT SHEET NUMBER DETAIL NUMBER SHEET NUMBER WINDOW TAG DOOR TAG WALL TAG KEYNOTE REVISION DELTA PROPERTY LINE CENTER LINE Name Elevation DATUM AT LEVEL ABBREVIATIONS @ AT A.B. ANCHOR BOLT ABV. ABOVE ACOUST ACOUSTICAL A/C AIR CONDITIONING ADJ. ADJUSTABLE A.F.F. ABOVE FINISH FLOOR AGG. AGGREGATE AL. ALUMINUM ALT. ALTERNATE APPX APPROXIMATE ARCH. ARCHITECTURE / ARCHITECTURAL BD. BOARD BEL. BELOW BET. BETWEEN B.G. BELOW GRADE BLDG. BUILDING BLKG. BLOCKING BOT. BOTTOM B.S. BOTH SIDES CEM. CEMENT CER. CERAMIC CHAM. CHAMFER CIR. CIRCLE CIRC. CIRCUMFERENCE CJT. CONTROL JOINT CL. CLOSET CLG. CEILING CLR. CLEAR C.M.U. CONCRETE MASONRY UNIT CNTR. COUNTER COL. COLUMN COMP. COMPUTER CONC. CONCRETE CONN. CONNECTION CONST. CONSTRUCTION CONT. CONTINUOUS CONTR. CONTRACT / CONTRACTOR CORRD. CORRIDOR CPT. CARPET DBL. DOUBLE DEMO. DEMOLITION DEP. DEPRESSED DIAM. DIAMETER DIM. DIMENSION DTL. DETAIL DWG. DRAWING DWR. DRAWER (E) EXISTING EA. EACH E.B. EXPANSION BOLT E.F. EACH FACE EL. ELEVATION ELEC. ELECTRICAL ELEV. ELEVATOR ENG. ENGINEERING / ENGINEERING EQ. EQUAL EQPMT EQUIPMENT E.S. EACH SIDE ESC. ESCALATOR EST. ESTIMATE E.W. EACH WAY EXP. JT. EXPANSION JOINT EXT. EXTERIOR FDN. FOUNDATION F. EXT. FIRE EXTINGUISHER F.F. FINISH FLOOR F.F.E. FINISH FLOOR ELEVATION F.F.L. FINISH FLOOR LINE F.G. FINISH GRADE FIN. FINISH FLR. FLOOR FLUR. FLUORESCENT F.O.C. FACE OF CONCRETE F.O.F. FACE OF FINISH F.O.M. FACE OF MASONRY F.O.S. FACE OF STUD FP. FIREPLACE FR. FRAME FT. FOOT / FEET FUT. FUTURE GA. GAUGE GALV. GALVANIZED G.C. GENERAL CONTRACTOR GL. GLASS GLB. GLU-LAM BEAM GL. BLK. GLASS BLOCK GR. GRADE/GRADING GT. GROUT GVL. GRAVEL GYP. GYPSUM HC. HANDICAPPED HDR. HEADER HDW. HARDWARE M.M. HOLLOW METAL HORIZ. HORIZONTAL HR. HOUR HT. HEIGHT HTG. HEATING HVAC. HEATING VENTILATIO AND AIR CONDITIONING HWD. HARDWOOD HWH. HOT WATER HEATER ID. INSIDE DIAMETER I.D. INTERIOR DESIGNER INS. INSULATION INT. INTERIOR JST. JOIST JT. JOINT LAM. LAMINATE / LAMINATED LT. LIGHT LIN. LINTEL LW. LIGHTWEIGHT MAX. MAXIMUM M.B. MACHINE BOLT MECH. MECHANICAL MFR. MANUFACTURER MIN. MINIMUM MISC. MISCELLANEOUS MRB. MARBLE MTL. MATERIAL MUL. MULLION (N) NEW N.I.C. NOT IN CONTRACT NO. NUMBER N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER OH. OVERHEAD O.H. OVERHANG OPNG. OPENING OPP. OPPOSITE PAR. PARALLEL PFB. PREFABRICATED PKG. PARKING PL. PLATE P.L. PROPERTY LINE PLAS. PLASTER PLAM. PLASTIC LAMINATE PLYWD. PLYWOOD PNT. PAINT / PAINTED PNL. PANEL PR. PAIR P.S.F. PER SQUARE FOOT P.S.I. PER SQUARE INCH P.T. PRESSURE TREATED P.T.D.F. PRESSURE TREATED DOUGLAS FIR PTN. PARTITION PT. POINT PVMT. PAVEMENT PWDR. POWDER R. RISER RAD. RADIUS RB.T. RUBBER TILE REF. REFERENCE REM. REMOVE REQD. REQUIRED RET. RETURN REV. REVISION RFH. ROOF HATCH R.O. ROUGH OPENING SCHED. SCHEDULE SEC. SECTION SF. SQUARE FEET SHTH. SHEATHING SHT. SHEET SIM. SIMILAR SPK. SPEAKER SPECS. SPECIFICATIONS SQ. SQUARE STRUCT. STRUCTURE / STRUCTURAL SUS. SUSPENDED T. TREAD T. & G. TONGUE AND GROOVE THK. THICK T.O.S. TOP OF SLAB T.O.W. TOP OF WALL TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE UR. URINAL VERT. VERTICAL VIN. VINYL W/ WITH W.C. WATER CLOSET WD. WOOD W.I.C. WALK IN CLOSET W/O WITHOUT WP. WATERPROOF WT. WEIGHT PUBLIC TRANSIT ACCESS 0.1 MILE TO CHESTNUT-OAK BUS STOP 0.1 < 0.5 = OK NO PARKING REPLACEMENT OR ADU PARKING REQUIRED PER THE FOLLOWING: A-0.0 TITLE SHEET A-3.0 SITE PLAN A-3.1 EXISTING PLANS A-4.0 PLANS A-4.1 ELEC PLAN AND SCHEDULES A-4.2 ROOF PLANS A-6.0 ELEVATIONS A-6.1 SECTIONS A-9.1 DETAILS A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIALECTIC ARCHITECTURE 1 10.13.2021 -MODIFICATION 2 11.08.2021 -MODIFICATION As indicated PI N E S T R E E T A D U 2 A-0.0 TITLE SHEET VF 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 PINE STREET ADU 2 423 E PINE ST & 423 PINE ST. UNIT #E , SANTA ANA, CA 92701 INDEX ARCHITECTURE STRUCTURAL S-0 NOTES & SCHEDULES S-1 FOUNDATION AND FRAMING S-2 CEILING AND ROOF SD-1 DETAILS DIGITAL STAMP GREEN G-1.1 TITLE-24 G-1.2 TITLE-24 G-1.3 TITLE-24 G-1.4 TITLE-24 G-1.5 TITLE-24 G-1.6 GREEN CODE G-1.7 GREEN CODE G-1.8 GREEN CODE Bldg #'s 101121794 & 95 APPROVALS: PLNG - C. SantanaBLDG - CSG POLICE - B. Martin PUBLIC WORKS - Y. Soto UP UP UP UP SITE PLAN NOTES CONTRACTOR TO PROVIDE SHORING AND BRACING PRIOR TO AND DURING ANY DEMOLITION AS REQUIRED A. CONTRACTOR TO PROVIDE WEATHER PROTECTION DURING DEMOLITION AND CONTSTRUCTION OF ADJOINING SURFACES AND SPACES. ALL AREAS NOT IMPACTED BY CONSTRUCTION SHALL BE LEFT IN SAME CONDITION FOUND PRIOR TO START OF CONSTRUCTION UNLESS OTHERWISE NOTED B. CONTRACTOR TO PROVIDE DUST CONTROL DURING DEMOLITION AND CONSTRUCTION C. SITE TO BE KEPT CLEAN AND IN ACCORDANCE WITH A SITE MAINTENANCE PLAND. STREET, CURB, AND GUTTER AND SIDEWALK ARE TO BE PROTECTED FROM DAMAGE SUCH AS INDENTATIONS FROM TRASH CONTAINER OR OTHER HEAVY OBJECTS PLACED ON PAVEMENT DURING CONSTRUCTION E. CONTRACTOR TO PROVIDE SECURITY CHAIN-LINK FENCE AROUND UNSECURED SITE AREAS F. VERIFY EXISTING HARDSCAPE AND LANDSCAPE TO BE REMOVED WITH LANDSCAPE DESIGNER, ARCHITECT, AND OWNER. ALL LANDSCAPING TO REMAIN SHALL BE MAINTAINED AND PROTECTED FROM DAMAGE G. CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, AND MATERIALS REQUIRED FOR OFFSITE IMPROVEMENTS H. ALL OFFSITE IMPROVEMENTS SHALL BE DONE IN ACCORDANCE WITH PUBLIC WORKS STANDARD CONSTRUCTION SPECIFICATIONS AND LOCAL REQUIREMENTS I. AN APPROVED SEISMIC GAS SHUTOFF VALVE SHALL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE (SEPARATE PERMIT REQUIRED) J. BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS, OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY K. RESIDENTIAL SWIMMING POOLS SHALL HAVE A POOL ENCLOSURE AS REQUIRED BY SECTION AG105 OF THE 2016 CRC: L. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM THE FOUNDATION WALLS WITH A MINIMUM FALL OF 6 INCHES WITHIN THE FIRST 10 FEET. WHERE LOT LINES, WALLS, SLOPES, OR OTHER PHYSICAL BARRIERS PROHIBIT MINIMUM FALL, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM STRUCTURE M. ALL HARDSCAPE ADJACENT TO THE STRUCTURE SHALL DRAIN SURFACE WATER AWAY FROM THE FOUNDATION A MINIMUM OF 1/4 INCH PER FOOT (2%) N. NOTIFY THE GRADING INSPECTOR PRIOR TO THE START OF GRADINGO. THESE PLANS ARE FOR BUILDING PERMIT ONLY. A SEPARATE PERMIT SHALL BE REQUIRED FOR LANDSCAPE ELEMENTS, HARDSCAPE, SWIMMING POOL, SPA, WATER FEATURES, AND FOUNTAINS. A SEPARATE PERMIT SHALL BE REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING. ARCHITECT WILL PROCESS PLANS THROUGH PLAN CHECK FOR THE BUILDING PERMIT ONLY. THE CONTRACTOR WILL BE RESPONSIBLE TO SIGN AND OBTAIN THE BUILDING PERMIT ON BEHALF OF THE OWNER. P. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL OTHER PERMITS. ANY APPLICATION FORMS OR DRAWINGS REQUIRED FOR SAID PERMITS WILL BE PREPARED BY THE SUBCONTRACTOR AND REMUNERATION SHALL BE INCLUDED IN THE BID Q. THE HEIGHT OF FENCES AND HEDGES ABOVE THE NATURAL GRADE SHALL NOT EXCEED 36 INCHES WITHIN THE REQUIRED FRONT YARD AND 6 FEET WITHIN THE REQUIRED SIDE YARDS AND REAR YARD R. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR THE LOCATION OF THE HOOK-UP. CONSTRUCTION SHALL NOT BE WITHIN 10 FEET OF ANY POWER LINES, WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND / OR ADDITIONAL EXPENSES S. PROVIDE A 42 INCH GUARDRAIL ON TOP OF THE WALL FOR YARD AREAS WHICH DROP VERTICAL MORE THAN 30 INCHES T. POOL ACCESS GATE SHALL BE EQUIPPED WITH SELF-CLOSING, SELF-LATCHING DEVICE WITH A RELEASE MECHANISM PLACED NO LOWER THAN 54" ABOVE THE FLOOR U. PINE STREET ALLEY N OA K S T R E E T 52' - 0" 13 5 ' - 0 " (E) 4 - UNIT, TWO STORY, MULTIFAMILY BUILDING. TYPE VB, NOT SPRIKLERED (E) 3 CAR GARAGE TO BE CONVERTED TO ACCESSORY DWELLING UNIT. 1 STORY. TYPE VB. NOT SPRINKLERED 10' - 1 1/2"29' - 6 1/2"12' - 4" 21 ' - 3 3 / 4 " 1' - 8 " 52' - 0" ASSUMED PROPERTY LINE 5' - 0 " 25 ' - 1 1 1 / 2 " 2% MIN SLOPE (E) ACCESSORY DWELLING UNIT. 1 STORY. TYPE VB. NOT SPRINKLERED FRONT SETBACK 26' - 6" REAR SETBACK 15' - 0" SIDE SETBACK 10' - 0" SIDE SETBACK 6' - 0" ADU SETBACK 4' - 0" ADU SETBACK 4' - 0" ADU SETBACK 4' - 0" (E) 6'-0" HIGH CMU WALL (E) 6'-0" HIGH CMU WALL (E) 6'-0" HIGH WOOD FENCE (E) 6'-0" HIGH WOOD FENCE (E) 8'-0" HIGH STEEL SECURITY FENCE W/ 3'-0" X 7'-0' SECURITY GATE (E) 8'-0" HIGH STEEL SECURITY FENCE W/ 3'-0" X 7'-0' SECURITY GATE (N) 2'-6" WOOD FENCE. NO PILASTERS (N) 2'-6" WOOD FENCE. NO PILASTERS (E) 6'-0" HIGH WOOD FENCE EXISTING DRIVEWAY EXISTING LAWN EXISTING LAWN EXISTING WALKWAY EXISTING WALKWAY EXISTING PAVED WALKWAY EXISTING PAVED WALKWAY LINE OF SECOND FLOOR WALL ABOVE G W (E) GAS METERS (E) WATER METER (E) ELECTRICAL PANEL WITH METERS (N) CONDENSER FOR ATTACHED ADU (E) CONDENSER FOR DETACHED ADU (E) SHARED WATER HEATER TO BE USED BY NEW ADU IN (E) MECH ROOM (N) SCREEN FOR CONDENSER. 4'-0" WOOD FENCE ON WOOD POST WITH 2 - 2'-0" X 4'-0" WOOD GATES. MATCH EXISTING WOOD FENCES ON PROPERTY IN COLOR AND STYLE UNIT B UNIT A UNIT E 4' - 0" 25' - 0" 44' - 8 1/2" 25' - 0" PROVIDE MAX 2'-6" FENCE HEIGHT AT CORNER TRIANGLE 25' W X 25' H PER SAMC 36-45 TO 36-47 PINE STREET ALLEY N OA K S T R E E T 52' - 0" 135' - 0" (E) 4 -UNIT, TWO STORY, MULTIFAMILY BUILDING. TYPE VB, NOT SPRIKLERED 10' - 1 1/2"29' - 6 1/2"12' - 4" 21' - 3 3/4" 1' - 8" 52' - 0" ASSUMED PROPERTY LINE 5' - 0" 25' - 11 1/2" 2% MIN SLOPE (E) DETACHED ACCESSORY DWELLING UNIT. 1 STORY. TYPE VB. NOT SPRINKLERED FRONT SETBACK 26' - 6" REAR SETBACK 15' - 0" SIDE SETBACK 10' - 0" SIDE SETBACK 6' - 0" ADU SETBACK 4' - 0" ADU SETBACK 4' - 0" ADU SETBACK 4' - 0" (E) 6'-0" HIGH CMU WALL (E) 6'-0" HIGH CMU WALL (E) 6'-0" HIGH WOOD FENCE (E) 6'-0" HIGH WOOD FENCE (E) 8'-0" HIGH STEEL SECURITY FENCE W/ 3'-0" X 7'-0' SECURITY GATE (E) 8'-0" HIGH STEEL SECURITY FENCE W/ 3'-0" X 7'-0' SECURITY GATE (E) 6'-0" HIGH WOOD FENCE EXISTING DRIVEWAY EXISTING LAWN EXISTING LAWN EXISTING WALKWAY EX I S T I N G WA L K W A Y EXISTING PAVED WALKWAY EXISTING PAVED WALKWAY LINE OF SECOND FLOOR WALL ABOVE G W (E) GAS METERS (E) WATER METER (E) ELECTRICAL PANEL WITH METERS (E) CONDENSER FOR DETACHED ADU (E) SHARED WATER HEATER UNIT B UNIT A A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP As indicated PI N E S T R E E T A D U 2 A-3.0 SITE PLAN Checker 2401.00 VF 04.09.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 SCALE: 1/8" = 1'-0"PROPOSED SITE PLAN 1 NOTE: THE APPLICANT/PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND/OR CLEARANCE ON-SITE THAT MAY AFFECT THE PROJECT SCALE: 1" = 10'-0"EXISTING SITE PLAN 2 UP DN BEDROOMBEDROOM LIVING ROOM BATHBATH KITCHEN UNIT B LIVING DINING KITCHEN BATH MECH LAUNDRY GARAGEGARAGEGARAGE UNIT A SCOPE OF PROJECT 209 208 210 202 203 201 207 204 205 211 (E) 3'-0" X 6'-8" (E ) 3 ' - 0 " X 6 ' - 8 " (E) 3'-0" X 6'-8" LIVING KITCHENBEDROOM BEDROOM BATH LIVING BEDROOM BATHBATH BEDROOM KITCHEN BEDROOM BATH BEDROOM BEDROOM BATH STAIRS BATH UNIT C UNIT A UNIT D 302 311 312 313 303 304 306 305 307 308 309 310 301 (E ) 3 ' - 0 " X 6 ' - 8 " (E) 3'-0" X 6'-8" A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP 1/4" = 1'-0" PI N E S T R E E T A D U 2 A-3.1 EXISTING PLANS Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 SCALE: 1/4" = 1'-0"EXISTING FIRST FLOOR PLAN 1SCALE: 1/4" = 1'-0"EXISTING SECOND FLOOR PLAN 2 2 A-6.0 1 A-6.0 2 A-4.1 PR O P E R T Y L I N E PR O P E R T Y L I N E 10' - 10 1/2"37' - 2 1/2"3' - 11" 20' - 11 1/2" 5' - 9" 4' - 2"5' - 1"5' - 1" 6' - 1 3/4"10' - 2"2' - 7"10' - 1 3/8" 5' - 3 1/4"23' - 8 7/8" 10' - 9 1/2" 10' - 2" EXISTING LAUNDRY EXISTING MECH EQ EQ EQ EQ 31" 15" 15" 2' - 0"7'-0" HDR. 3' - 0" CLR. MIN. 1' - 8" 1' - 8" BEDROOM 1 104 BEDROOM 2 105 LIVING / KITCHEN 102 BATHROOM 103 SCM 36" REF SS101 102 103 104 106 105 101 102 103 67 6 6 13 13 13 13 14 14 15 24 37 13 EGRESS 20 20 EGRESS 37 FOR (E) 3.5" CONCRETE SLABS, INSTALL A LAYER OF REDGARD WATERPROOFING FLUID APPLIED VAPOR BARRIER. INSTALL PER MANUFACTURER'S SPECIFICATIONS. ESR 1413 33 DW 17 18 ADU SETBACK 4' - 0" 2 A-6.1 2 A-6.1 1 A-6.1 HALL 101 1 1/2"3' - 0" WOOD FLOOR 8'-0' CLG 221.15 SF WINDOW 103 11.00 / 221.15 x 100 = 4.9% VENT 17.78 / 221.15 X 100 = 8.0% LIGHT WOOD FLOOR 8'-0' CLG 100.42 SF WINDOW 101 10.00 / 100.42 x 100 = 9.96% VENT 17.78 / 100.42 X 100 = 17.70% LIGHT 5' - 0"3 1/2" PROVIDE FURRING WALL AT PLUMBING WALL. NO PENETRATIONS AT 1HR WALL. 27 38 36" RANGE 3' - 0" 107 (E) SHARED WATER HEATER TO BE USED BY NEW ADU (N) CONDESER LOCATION UNIT #E WOOD FLOOR 8'-0' CLG 100.83 SF WINDOW 102 10.00 / 100.83 x 100 = 9.92% VENT 17.78 / 100.83 X 100 = 17.63% LIGHT PROVIDE BACKING FOR FLOOR MOUNTED GRAB BAR FLOOR PLAN KEY NOTES 1 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON ALL GARAGE WALLS, CEILINGS, POSTS, ANS SUPPORTING BEAMS, AND SHALL EXTEND FROM THE GARAGE CONCRETE SLAB TO THE CEILING 2 GARAGE DOOR OPENER: PUSH BUTTON SHALL BE PRE-WIRED BEFORE GYPSUM BOARD IS INSTALLED 3 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS IN ENCLOSED USEABLE SPACE UNDER STAIRS 4 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS OF SHAFT ENCLOSURES 5 PROVIDE SELF-CLOSING, SELF-LATCHING DEVICE ON 20 MINUTE FIRE RATED DOOR, SEE DOOR SCHEDULE 6 PROVIDE STATE FIRE MARSHALL APPROVED SMOKE ALARMS (DETECTORS) AS SHOWN ON THE PLANS AND ACCORDING TO SECTION R314.4 OF THE 2016 CRC. ALARMS SHALL BE HARD WIRED TO SEPARATE CIRCUITS WITH BATTERY BACK UP FOR NEW CONSTRUCTION (907.2.11.4). IN EXISTING SFD, SMOKE DETECTOR MAY BE BATTERY OPERATED. ALARMS SHALL BE LOCATED IN EACH SLEEPING ROOM AND CENTRALLY LOCATED IN CORRIDORS GIVING DIRECT ACCESS TO SLEEPING ROOMS, WHEN SLEEPING ROOMS ARE ON AN UPPER LEVEL, A SMOKE ALARM SHALL BE LOCATED IN CLOSE PROXIMITY TO STAIRWAYS. ALARMS SHALL BE AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING WHICH THEY SERVE. ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS. 7 PROVIDE STATE MARSHALL APPROVED CARBON MONOXIDE ALARMS AS SHOWN ON PLANS AND ACCORDING TO SECTION R315 OF THE 2016 CRC. ALARMS SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL BURNING APPLIANCES ARE INSTALLED, INCLUDING FIRE PLACES, AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. CARBON MONOXIDE ALARMS SHELL BE PROVIDED IN EACH SLEEPING AREA, IMMEDIATELY OUTSIDE EACH SLEEPING AREA, AND ON EVERY LEVEL OF THE DWELLING UNIT, INCLUDING BASEMENTS. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATED ALL OF THE ALARMS IN THE DWELLING. 8 30" X 30" ROOF ACCESS, SEE DETAILS 9 30" X 30" ATTIC ACCESS, SEE DETAILS 10 30" X 54" ACCESS WITH PULL-DOWN LADDER, SEE DETAILS 11 CRAWLSPACE (UNDERFLOOR) ACCESS, SEE DETAILS 12 6" X 14" UNDERFLOOR SCREENED VENT, SEE EXTERIOR ELEVATIONS AND DETAILS 13 BUILT-IN CABINETRY 14 CLOSET MILLWORK, SEE DETAILS FOR LEVELS A, B, C, D, AND E 15 BATHROOM EXHAUST FAN CAPABLE OF PROVIDING THE MINIMUM RATE OF 50 CUBIC FEET PER MINUTE (12 L/s) CONTINOUS VENTILATION PER SECTION R303.3 OF THE 2016 CRC. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED FDIRECTLY TO THE OUTSIDE. EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT. ROOMS CONTAINING BATHTUBS, SHOWER, SPAS, AND SIMILAR BATHINGFIXTURES, SHALL BE MECHANICALLY VENTILATED. SEPARATE MECHANICAL PERMIT MAY BE REQUIRED (1203.5.2.1) 16 PRE-FABRICATED FIREPLACE UNIT: FMI MODEL DVF42NH, DIRECT VENT SEALED COMBUSTION (PFS REPROT #09-95: ANSI STANDARD Z21 .50b-2009 VENTED GAS FIREPLACES CSA 2.22b-2009), WITH HERRINGBONE BRICK PATTERNS. PROVIDE UNIT CONTROLS AND VENTING SYSTEMS PER MANUFACTURER'S RECOMMENDATIONS, SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION 17 WASHER: PROVIDE RECESSED HOT AND COLD WATER DRAIN STAND PIPE, AND FLOOR DRAIN UNDER WASHER 18 DRYER: PROVIDE WEATHER HOOD VENT WITH DAMPER TO OUTSIDE AIR AT ROOF. VENT DUCT SHALL BE MINIMUM 4" DIAMETER, SMOOTH GALVANIZED METAL, LIMITED TO TWO (2) 14'-0" LEGNTH WITH TWO (2) ELBOWS, SEE MECHANICAL PLANS. 19 GAS METER. PROVIDE EARTHQUAKE VALVE 20 MINI SPLIT REGISTER WITH ELECTRIC HEAT PUMP. SEE TITLE 24. HEATER CAPABLE OF MAINTAINING A MIN. ROOM TEMPERATURE OF 68 DEG. F AT A POINT 3 FEET ABV THE FLOOR AND 2 FEET FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT TE DESIGN TEMPERATURE 21 ELECTRICAL PANEL, SEE ELECTRICAL PLANS 22 PHONE PANEL: ALL LINES TO BE HOME RUNS, SEE ELECTRICAL AND A/V PLAN 23 HEAT PUMP WATER HEATER. PROVIDE REQUIRED STRAPPING AND ENCLOSURE. SEE TITLE 24 DRAWINGS 24 TUB / SHOWER WITH TILE / STONE FINISH ON WALLS, FLOORS TO CELING, SEE INTERIOR ELEVATIONS 25 SHOWER WITH TILE / STONE FINISH ON WALLS, FLOOR TO CEILING, SEE INTERIOR ELEVATIONS 26 FRAMELESS 3/8" THICK TEMPERED GLASS ENCLOSURE WITH SET-IN GLAZING CHANNEL, SEE SPECS AND INTERIOR ELEVATIONS 27 SOAP / SHAMPOO NICHE, SEE DETAILS AND INTERIOR ELEVATIONS FOR SIZE 28 WATER METER LOCATION 29 PROVIDE 30" X 24" WATER CLOSET CLEARANCE 30 "INSTA-HOT" DISPENSER AND WATER FILTRATION SYSTEM, VERIFY WITH OWNER 31 PROVIDE PURIFIED COLD WATER SUPPLY LINE TO ICE-MAKER WITH RECESSED SHUT-OFF VALVE, VERIFY WITH MANUFACTURER 32 LINE OF EXHAUST HOOD ABOVE, VENT TO OUTSIDE AIR WITH REMOTE EXHAUST FANS. VERIFY VENTING REQUIREMENTS WITH MECHNAICAL PLANS AND MANUFACTURER'S RECOMMENDATIONS. 33 HOSE BIBB IN RECESSED ENCLOSURE, FIXTURE TO MATCH WINDOW / DOOR FRAME FINISH. COORDINATE LOCATIONS WITH ARCHITECT. 36 ELECTRIC VEHICLE CHARGING STATION, INSTALL CONDUIT AND ELECTRICAL PANEL CAPACITY FOR FUTURE VEHICLE PARKING FOR AT LEAST 3% OF THE TOTAL PARKING SPACES BUT NOT LESS THAN ONE. (4.107 AND A5.106.5.33) 34 GUARDRAIL, 42" ABOVE FINISH FLOOR 35 HANDRAIL, 34-38" ABOVE FINISH FLOOR WITH 1 1/2" - 2" HANDGRIP, SEE DETAILS SHEET A-9.5 FLOOR PLAN NOTES VERIFY ALL EXISTING CONDITIONS AND INFORM ARCHITECT OF ANY DISCREPANCIES B DO NOT SCALE DRAWINGS, REFER TO DIMENSIONS AS SHOWNA CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS OR INFORMATIONC ALL DIMENSIONS ARE TO FACE OF CONCRETE OR FACE OF STUDD INSULATION: PROVIDE R-19 MIN. AT ALL EXTERIOR WALLS, INCLUDING GARAGE. PROVIDE R-30 INSULATION IN ATTIC SPACES. PROVIDE R-19 INSULATION AT ALL INTERIOR WALLS. PROVIDE R-30 INSULATION AT ALL FLOOR FRAMING. SEE TITLE 24 FOR ADDITIONAL REQUIREMENTS. PROVIDE INSULATION AROUND PLUMBING PIPES AND HVAC DUCTS, SEE MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL REQUIREMENTS E ROUGH CARPENTER TO COORDINATE FRAMING LAYOUT WITH LIGHTING, PLUMBING, AND MECHANICAL PLANS AND INFORM ARCHITECT OF ANY DISCREPANCIES. ALL REQUIRED FURRING, SOFFITS, VOLUME CEILINGS AND NON-STRUCTURAL FRAMING SHALL BE INCLUDED IN BID F REFER TO REFLECTED CEILING PLANS, BUILDING SECTIONS, AND INTERIOR ELEVATIONS FOR VOLUME CEILINGS G ALL EXTERIOR STUDS SHALL BE 2X4 FRAMING OR MULTIPLE ROWS OF 2X4 FRAMING UNLESS OTHERWISE NOTED. ALL INTERIOR WALLS SHALL BE 2X4 FRAMING UNLESS OTHERWISE NOTED. SPACING AND SPECIFICATION ARE PER STRUCTURAL H PROVIDE DRAFT STOPS AS REQUIRED IN SECTION R302.11 OF THE 2011 CRC OR CURRENT BUILDING CODE: ENCLOSED SPACES IN STUD WALLS, PARTITIONS, AND FURRED WALLS SHALL HAVE FIRE STOPS AT TOP AND BOTTOM AND AT MID POINT IN WALLS MORE THAN 10 FEET HIGH I CONTRACTOR SHALL PROVIDE ALL REQUIRED SHIMMING SO THAT FINISH FLOOR MATERIALS ALIGN AT THE SAME ELEVATION, UNLESS OTHERWISE NOTED J CONTRACTOR SHALL COORDINATE ALL WINDOW AND DOOR ROUGH OPENING WITH MANUFACTURER K PROVIDE EMERGENCY EGRESS FROM SLEEPING ROOMS ACCORDING TO SECTION R310 OF THE 2011 CRC: MINIMUM 24 INCHES CLEAR HEIGHT, 20 INCHES CLEAR WIDTH; 5.7 SQ. FT. MINIMUM AREA (5.0 SQ. FT. AT GRADE), AND 44 INCHES MAXIMUM TO WINDOW SILL L FOR ALL PLUMBING FIXTURES AND APPLIANCES VERIFY WITH INTERIOR DESIGNERM PROVIDE A WHOLE-HOUSE VENTILATION SYSTEM FOR ALL HABITABLE SPACESN 37 PROVIDE A SMOOTH LANDING WITH A MINIMUM 36" LENGTH IN THE DIRECTION OF TRAVEL. 38 MEDICINE CABINET NEW WALL EXISTING WALL WALL LEGEND DEMO WALL 1-HR RATED WALL PR O P E R T Y L I N E COLUMNS TO REMAINBEAM TO REMAIN GARAGE GARAGE GARAGE COLUMN TO REMAIN COLUMN TO REMAIN REMOVE EXISTING WALL LOCATION OF (N) WINDOW REMOVE (E) GARAGE DOORS PR O P E R T Y L I N E 10' - 10 1/2"37' - 2 1/2"3' - 11" 2 A-6.1 1 A-6.1 1 A-6.1 DEMOLITION FLOOR PLAN NOTES CONTRACTOR NOTE: BIDDERS, BEFORE SUBMITTING PROPOSALS, SHALL VISIT AND CAREFULLY EXAMINE THE AREA AFFECTED BY THIS WORK TO FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS AND THE DIFFICULTIES THAT WILL ATTEND THE EXECUTION OF THIS WORK. SUBMISSIONS OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE IN AN ATTEMPT TO OBSERVE DIFFICULTIES THAT WOULD BE ENCOUNTERED ONLY IF SUCH AN EXAMINATION HAD BEEN MADE. A. CONTRACTOR SHALL TAKE ALL PRECAUTIONS DURING DEMOLITION WORK SO AS NOT TO CAUSE ANY DAMAGE TO EXISTING WORK TO REMAIN. B. BEFORE ANY REMOVAL WORK IS STARTED, ELECTRICAL CONTRACTOR SHALL VERIFY THAT SERVICE HAS BEEN CUT TO THAT AREA EXCEPT AS NOTED BELOW. C. CONTRACTOR SHALL COORDINATE HIS WORK WITH THAT OF THE MECHANICAL AND ELECTRICAL SUBCONTRACTORS BEFORE WORK IS STARTED. D. REMOVE EXISTING PARTITIONS WHERE INDICATED ON PLANS AND REQUIRED BY FIELD CONDITIONS. E. CONTRACTOR NOTE THAT ALL EXISTING CARPETING, BASE AND ALL OTHER FINISHES ARE TO BE REMOVED, UNLESS OTHERWISE NOTED. F. CONTRACTOR SHALL REMOVE ALL DEBRIS FROM BUILDING AND SITE AT THE END OF EACH DAY. ACCUMULATION OF RUBBISH SHALL NOT BE PERMITTED. SPRINKLE ALL WORK TO LAY OUT SO IT DOES NOT BECOME A NUISANCE TO OTHERS AT WORK. G. AT NO TIME SHOULD THE CONTRACTOR ALLOW THE DEMOLITION WORK OR STORAGE OF DEBRIS TO CAUSE INTERFERENCE WITH ANY REQUIRED MEANS OF EGRESS OR CAUSE A HAZARDOUS CONDITION. H. CONTRACTOR NOTE THAT ACOUSTIC TILE AND GRID CEILING IS TO REMAIN UNLESS OTHERWISE NOTED OR REQUIRED BY THESE DRAWINGS, CEILING LIGHTS, DIFFUSERS, TILE, ETC., WILL BE MODIFIED OR ALTERED AS REQUIRED BY NEW FLOOR PLAN. ALL COMPONENTS IN ACCEPTABLE CONDITION ARE TO BE REUSED. I. MAINTAIN AT ALL TIMES THE EMERGENCY LIGHTING THROUGHOUT THE BUILDING DURING DEMOLITION WORK, AS WELL AS RECONSTRUCTION WORK. PROVIDE ALL NECESSARY TEMPORARY LIGHTING, PARTITIONS, DUST COVERS, DROP COVERS, ETC. J. COORDINATE WITH CONTRACTOR FOR DEMOLITION WORK AND DISCONNECT LINE END OF CONDUCTORS WHICH ARE DIRECTLY AFFECTED BY DEMOLITION OR WHICH FEED EQUIPMENT. K. CUT, CAP AND FLUSH ALL ABANDONED STUBS, AND PROVIDE REQUIRED PATCHING. PROVIDE ABANDONED OUTLETS WITH BLANK COVER. L. PROVIDE BOX AND SPLICE WIRES WHERE IT IS REQUIRED TO MAINTAIN CONTINUITY OF CIRCUITS OR REMOVE WIRING AND SPLICE WIRE AT NEAREST ACTIVE BOX FROM OUTLETS WHICH HAVE BEEN TERMINATED. M. COORDINATE ALL WORK, SCHEDULING, ETC., WITH BUILDING OWNER.N. INCLUDE IN BID ALL DEMOLITION WORK AS REQUIRED TO COMPLETE ALL NEW WORK AS DELINEATED BY ARCHITECTURAL AND ENGINEERING DRAWINGS WHETHER SHOWN ON DRAWINGS OR NOT I.E.; COORDINATION OF ALL SUBCONTRACTORS WORK, ELECTRICAL, PLUMBING, HVAC, CUTTING, PATCHING, ETC. O. CUT ALL EXISTING WALLS/PARTITIONS ETC., AS REQUIRED FOR ALL ELECTRICAL, HVAC, PLUMBING AND SPRINKLER WORK, INCLUDE ALL PATCHING AND REFINISHING. P. CONTRACTOR IS TO REMOVE ALL MISCELLANEOUS ATTACHED ITEMS, BOARDS, SCREENS, TV'S, ETC. VERIFY DISPOSITION WITH OWNER AND EITHER RETURN TO OWNER OR DISCARD. Q. WHERE ATHC IS TO BE REMOVED: REMOVE ANY AND ALL GYPSUM BOARD CEILINGS, AND/ OR SOFFITS, IN THE AFFECTED AREA. R. ANY STAIR REMOVAL NOTES APPLY TO ENTIRE STAIR TO ITS TERMINATION, I.E.; AT ROOF OR AT SECOND FLOOR), WHETHER STATED OR NOT. S. ALL EXISTING POKE-THROUGH FITTINGS NOT BEING REUSED SHALL BE REMOVED. ALL CORE-DRILLED HOLES SHALL BE PATCHED. INSTALL NEW METAL DECKING, TACK WELD TO UNDERSIDE OF EXISTING DECK, POUR CONCRETE TO FINISH FLUSH WITH EXISTING CONCRETE FLOOR SLAB. T. SEE CONSTRUCTION PLANS & FURNITURE/ELECTRICAL PLANS FOR NEW POKE-THROUGH LOCATIONS. U. PRIOR TO THE START OF DEMOLITION, CONTRACTOR SHALL VERIFY THAT ALL WALLS AND SOFFITS TO BE REMOVED DO NOT CONTAIN PLUMBING OR ELECTRICAL RUNS FROM ABOVE OR BELOW. V. TYPE X 5/8" GYPSUM BOARD. MIN 1-HR EXTERIOR WALL PER 15-1.3 AND 15-1.15 FROM TABLE 721.1(2) OF CRC BATT INSULATION 2X4 #1 DF STUD SHEATHING PER STRUCTURAL MIN. 7/8" CEMENT STUCCO PLASTER. 2" × 4" wood studs 16" on center with 7/8" cement plaster (measured from the face of studs) on the exterior surface with interior surface treatment as required for interior wood stud partitions in this table. Plaster mix 1:4 for scratch coat and 1:5 for brown coat, by volume, cement to sand. 2" × 4" wood studs at 16" with double top plates, single bottom plate; interior and exterior sides covered with 5/8" Type X gypsum wallboard and sheathing, respectively, 4' wide, applied horizontally or vertically with vertical joints over studs, and fastened with 21/4" Type S drywall screws, spaced 12" on center. Cavity to be filled with 31/2" mineral wool insulation. A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP As indicated PI N E S T R E E T A D U 2 A-4.0 PLANS Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 SCALE: 3/8" = 1'-0"PROPOSED FLOOR PLAN 1 SCALE: 3/8" = 1'-0"DEMOLITION PLAN 2 SCALE: 1 1/2" = 1'-0"1HR WALL 3 AGE IN PLACE NOTES: DOORBELL BUTTONS - DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 MM) MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. (CRC R327.1.4) AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH CRC R327.1. • REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. • REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH (51 MM BY 203 MM) NOMINAL LUMBER. [11/2 INCH BY 71/4 INCH (38 MM BY 184 MM) ACTUAL DIMENSION] OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES (812.8 MM) AND 391/4 INCHES (997 MM) ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. • WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. • SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. • BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES (152.4 MM) ABOVE THE BATHTUB RIM. O EXCEPTIONS: O WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. O REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORY- INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. O SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. O BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION OF REINFORCEMENT SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. O REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETE SLAB FLOORS. DOOR & WINDOW SCHEDULE NOTES ALL GLAZING SHALL BE SPECIFIED PER TITLE 24 UNLESS OTHERWISE NOTED. PROVIDE SAMPLE FOR REVIEW AND APPROVAL BY ARCHITECT AND OWNER A. WHERE REQUIRED BY CODE, ALL EXTERIOR AND INTERIOR GLAZING SHALL BE TEMPERED UNLESS OTHERWISE NOTED, SEE GLAZING REQUIREMENTS ON SHEET A-1.0 B. ALIGN TOPS OF WINDOWS WITH TOPS OF DOORS IN A LEVEL PLANE ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED C. CONTRACTOR SHALL VERIFY ALL WINDOW AND DOOR ROUGH OPENING DIMENSIONS WITH MANUFACTURER PRIOR TO FRAMING D. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL DOOR AND WINDOW UNITS, SYSTEMS, AND ASSEMBLIES WITH FIELD VERIFIED DIMENSIONS FOR ARCHITECT AND OWNER APPROVAL PRIOR TO FABRICATION. CONTRACTOR SHALL REVIEW AND APPROVE SHOP DRAWINGS PRIOR TO SUBMITTAL TO ARCHTIECT AND OWNER E. SEE SHEET A-1.0 FOR SECURITY REQUIREMENTSF. ALL OPERABLE WINDOWS SHALL BE EQUIPPED WITH SECURITY DEVICESG. ALL FRAMES TO MATCH CORRESPONDING WINDOW AND DOOR FINISH UNLESS OTHERWISE NOTED H. SEE FLOOR PLANS AND ELEVATIONS FOR WINDOW AND DOOR SWING DIRECTIONI. ALL DOORS TO INTERIOR ACCESSIBLE ROOMS SHALL BE A MINIMUM 32" IN CLEAR WIDTH J. ALL REQUIRED EMERGENCY EGRESS WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENABLE AREA OF 5.7 SQUARE FEET. THE MINIMUM NET CLEAR OPENEABLE HEIGHT DIMENSION SHALL BE 24". THE MINIMUM NET CLEAR OPENABLE WIDTH DIMENSION SHALL BE 20". WHEN WINDOWS ARE PROVIDED AS A MEANS OF ESCAPE OR RESCUE THEY SHALL HAVE A FINISHED SILL HEIGHT NOT MORE THAN 44" ABOVE FINISH FLOOR K. ALL OPERABLE WINDOWS SHALL BE EQUIPPED WITH INTEGRAL ROLL DOWN INSECT SCREENS UNLESS OTHERWISE NOTED L. INTERIOR DOORS SHALL HAVE A CLEARANCE NOT MORE THAN 3/8" ABOVE FINISH FLOOR M. ALL EXTERIOR METAL THRESHOLD FINISHES SHALL MATCH HARDWARE UNLESS OTHERWISE NOTED N. ALL WOOD DOORS SHALL BE SOLID WOOD UNLESS OTHERWISE NOTEDO. ALL DOORS SHALL HAVE A MINIMUM OF 3 HINGES PER LEAF UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PROVIDE TEMPORARY HINGES AS REQUIRED. VERIFY FINISH AND HARDWARE SPECIFICATIONS WITH INTERIOR DESIGNER P. PROVIDE WINDOW, DOOR, AND HARDWARE SAMPLE MOCK-UPS FOR REVIEW AND APPROVAL BY ARCHITECT AND OWNER PRIOR TO PURCHASE OR FABRICATION Q. ALL WINDOWS AND DOORS SHALL MEET OR EXCEED MILLWORKS, ETC. WINDOW AND DOORS OR APPROVED EQUAL. PROVIDE MOCK-UP SAMPLES FOR ARCHITECT AND OWNER REVIEW AND APPROVAL R. ALL WINDOW AND DOOR FINISHES SHALL BE APPROVED BY ARCHITECT AND OWNER S. ARCHITECTURAL ELECTRICAL AND LIGHTING SYMBOLS SYMBOL DESCRIPTION RECESSED DOWNLIGHT RECESSED DOWNLIGHT - WATER PROOF S CM D WP SURFACE MOUNTED LIGHT PENDANT LIGHT CEILING MOUNTED LIGHT - CHANDELIER WP SCONCE EXTERIOR SCONCE SMOKE DETECTOR CARBON MONOXIDE DETECTOR EXHAUST FAN GFCI WP OUTLET OUTLET - HALF HOT OUTLET - GROUND FAULT CIRCUIT INTERRUPTOR OUTLET - EXTERIOR WATER PROOF S S 3 SWITCH SWITCH - 3 WAY S DIM SWITCH - DIMMER GARBAGE DISPOSAL TELEPHONE TV DATA SURFACE MOUNTED FLUORESCENT LIGHT RECESSED PIN LIGHTP S D SWITCH - DOOR ACTIVATED DOORBELL EXTERIOR SWING A LINE OF FINISH FLOOR INTERIOR SWING C CLOSET SLIDER D HEAD HEIGHT 6' - 8" 3' - 0"2' - 8"4' - 0" FRAMELESS SHOWER DOOR E 2' - 8" 4" INTERIOR SWING B 3' - 0" SLIDER A LINE OF FINISH FLOOR SLIDER B HEAD HEIGHT 6' - 8" 10.00 SF OPENABLE AREA 15.88 SF GLAZING 2' - 8" 4' - 0" 2' - 6"2' - 6" 5' - 0" 3' - 0" 3' - 8" 3' - 0"3' - 0" 6' - 0" 11.00 SF OPENABLE AREA 17.78 SF GLAZING SLIDER C 2' - 2" 4' - 6" 6' - 0" SLIDER D 3' - 4" 3' - 4" 6' - 0" SLIDER E 3' - 8" 3' - 0" 6' - 0" SLIDER F 3' - 4" 3' - 4" 5' - 4" SLIDER G 1' - 8" 5' - 0" 4' - 0" SLIDER H 2' - 2" 4' - 6" 4' - 0" SLIDER I 4' - 2" 2' - 6" 4' - 0" SLIDER J 3' - 8" 3' - 0" 3' - 0" SCM SS TO MOTION SENSOR WP GF C I GFCIGFCI GF C I S S S S S S S S 5' - 9"5' - 9"5' - 9" EQ EQ WP ELEC RANGE MAX 48" A.F.F TO TOP OF DOORBELL ASSEMBLY PER R327.1.4 GF C I GF C I 2' - 4" 3' - 6" 2' - 9 1/2" 1' - 0" 2' - 0"11" 6 1/2" LEVEL 1 SUB LEVEL 2 SUB T.O. PLATE MULTIFAMILTY 37.21' 3' 3'6' 6.67' ELEVATION AREA = 37.21 X 18 = 669.78 UNPROTECTED OPENINGS = 20.01 + 20.00 + 20.00 + 9.00 + 40.02 = 109.03 109.03 / 669.78 X 100 = 17% 17% < 45% PER CRC TABLE 708.5 20.01 20.00 20.00 9.00 40.02 2 A-6.1 2 A-6.1 4' 5' 4' 5'6.67' 3' A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP As indicated PI N E S T R E E T A D U 2 A-4.1 ELEC PLAN AND SCHEDULES Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 DOOR SCHEDULE ID ROOM # ROOM NAME TYPE SIZE MAT'L FINISH GLAZING HARDWARE REMARKS WIDTH HEIGHT THICKNESS LEVEL 1 FF 101 101 HALL A 3' - 0" 6' - 8" 0' - 1 3/8" SOLID WOOD PAINTED MORTISE LOCK 102 104 BEDROOM 1 C 2' - 8" 6' - 8" 0' - 1 3/8" HOLLOW CORE WOOD PAINTED PRIVACY 103 105 BEDROOM 2 C 2' - 8" 6' - 8" 0' - 1 3/8" HOLLOW CORE WOOD PAINTED PRIVACY 104 103 BATHROOM B 3' - 0" 6' - 8" 0' - 1 3/8" HOLLOW CORE WOOD PAINTED PRIVACY 105 104 BEDROOM 1 D 4' - 0" 6' - 8" 0' - 1 3/8" HOLLOW CORE WOOD PAINTED PULL 106 105 BEDROOM 2 D 4' - 0" 6' - 8" 0' - 1 3/8" HOLLOW CORE WOOD PAINTED PULL 107 103 BATHROOM E 2' - 8" 6' - 4" 0' - 1"GLASS PULL TEMPERED ADU WINDOW SCHDULE ID TYPE ROOM # ROOM NAME SASH SIZE SILL HEIGHT HEAD HEIGHT MAT'L FINISH SCREENS HARDWARE GLAZING U FACTOR SHGC REMARKSW H 101 A 104 BEDROOM 1 5' - 0" 4' - 0" 2' - 8" 6' - 8" VINYL PREFINISHED YES .30 .23 EGRESS 102 A 105 BEDROOM 2 5' - 0" 4' - 0" 2' - 8" 6' - 8" VINYL PREFINISHED YES .30 .23 EGRESS 103 B 102 LIVING / KITCHEN 6' - 0" 3' - 8" 3' - 0" 6' - 8" VINYL PREFINISHED YES TEMPERED .30 .23 SCALE: 3/8" = 1'-0"ELECTRICAL PLAN 1 SCALE: 1/4" = 1'-0"MULTIFAMILY ELEVATION 2 MULTIFAMILY WINDOW SCHDULE ID TYPE SASH SIZE SILL HEIGHT HEAD HEIGHT MAT'L FINISH SCREENS HARDWARE GLAZING U FACTOR SHGC REMARKSW H 201 J 3' - 0" 3' - 0" 3' - 8" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 202 J 3' - 0" 3' - 0" 3' - 8" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 203 D 6' - 0" 3' - 4" 3' - 8" 7' - 0" VINYL PREFINISHED WHITE YES 0.32 0.23 EGRESS 204 C 6' - 0" 4' - 6" 2' - 2" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 205 I 4' - 0" 2' - 6" 4' - 2" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 206 I 4' - 0" 2' - 6" 3' - 0" 5' - 6" VINYL PREFINISHED WHITE YES 0.32 0.23 207 C 6' - 0" 4' - 6" 2' - 2" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 208 H 4' - 0" 4' - 6" 2' - 2" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 209 H 4' - 0" 4' - 6" 2' - 2" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 210 G 4' - 0" 5' - 0" 2' - 2" 7' - 2" VINYL PREFINISHED WHITE YES 0.32 0.23 EGRESS 211 E 6' - 0" 3' - 0" 3' - 8" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 TEMPERED 301 J 3' - 0" 3' - 0" 5' - 0" 8' - 0" VINYL PREFINISHED WHITE YES 0.32 0.23 302 J 3' - 0" 3' - 0" 3' - 8" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 303 D 6' - 0" 3' - 4" 3' - 0" 6' - 4" VINYL PREFINISHED WHITE YES 0.32 0.23 EGRESS 304 F 5' - 4" 3' - 4" 3' - 0" 6' - 4" VINYL PREFINISHED WHITE YES 0.32 0.23 EGRESS 305 J 3' - 0" 3' - 0" 3' - 8" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 306 J 3' - 0" 3' - 0" 3' - 8" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 307 D 6' - 0" 3' - 4" 3' - 4" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 EGRESS 308 D 6' - 0" 3' - 4" 3' - 4" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 EGRESS 309 D 6' - 0" 3' - 4" 3' - 4" 6' - 8" VINYL PREFINISHED WHITE YES 0.32 0.23 EGRESS 310 H 4' - 0" 4' - 6" 2' - 5" 6' - 11" VINYL PREFINISHED WHITE YES 0.32 0.23 311 H 4' - 0" 4' - 6" 2' - 5" 6' - 11" VINYL PREFINISHED WHITE YES 0.32 0.23 312 G 4' - 0" 5' - 0" 2' - 5" 7' - 5" VINYL PREFINISHED WHITE YES 0.32 0.23 EGRESS 313 E 6' - 0" 3' - 0" 3' - 11" 6' - 11" VINYL PREFINISHED WHITE YES 0.32 0.23 TEMPERED DEMOLITION FLOOR PLAN NOTES CONTRACTOR NOTE: BIDDERS, BEFORE SUBMITTING PROPOSALS, SHALL VISIT AND CAREFULLY EXAMINE THE AREA AFFECTED BY THIS WORK TO FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS AND THE DIFFICULTIES THAT WILL ATTEND THE EXECUTION OF THIS WORK. SUBMISSIONS OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE IN AN ATTEMPT TO OBSERVE DIFFICULTIES THAT WOULD BE ENCOUNTERED ONLY IF SUCH AN EXAMINATION HAD BEEN MADE. A. CONTRACTOR SHALL TAKE ALL PRECAUTIONS DURING DEMOLITION WORK SO AS NOT TO CAUSE ANY DAMAGE TO EXISTING WORK TO REMAIN. B. BEFORE ANY REMOVAL WORK IS STARTED, ELECTRICAL CONTRACTOR SHALL VERIFY THAT SERVICE HAS BEEN CUT TO THAT AREA EXCEPT AS NOTED BELOW. C. CONTRACTOR SHALL COORDINATE HIS WORK WITH THAT OF THE MECHANICAL AND ELECTRICAL SUBCONTRACTORS BEFORE WORK IS STARTED. D. REMOVE EXISTING PARTITIONS WHERE INDICATED ON PLANS AND REQUIRED BY FIELD CONDITIONS. E. CONTRACTOR NOTE THAT ALL EXISTING CARPETING, BASE AND ALL OTHER FINISHES ARE TO BE REMOVED, UNLESS OTHERWISE NOTED. F. CONTRACTOR SHALL REMOVE ALL DEBRIS FROM BUILDING AND SITE AT THE END OF EACH DAY. ACCUMULATION OF RUBBISH SHALL NOT BE PERMITTED. SPRINKLE ALL WORK TO LAY OUT SO IT DOES NOT BECOME A NUISANCE TO OTHERS AT WORK. G. AT NO TIME SHOULD THE CONTRACTOR ALLOW THE DEMOLITION WORK OR STORAGE OF DEBRIS TO CAUSE INTERFERENCE WITH ANY REQUIRED MEANS OF EGRESS OR CAUSE A HAZARDOUS CONDITION. H. CONTRACTOR NOTE THAT ACOUSTIC TILE AND GRID CEILING IS TO REMAIN UNLESS OTHERWISE NOTED OR REQUIRED BY THESE DRAWINGS, CEILING LIGHTS, DIFFUSERS, TILE, ETC., WILL BE MODIFIED OR ALTERED AS REQUIRED BY NEW FLOOR PLAN. ALL COMPONENTS IN ACCEPTABLE CONDITION ARE TO BE REUSED. I. MAINTAIN AT ALL TIMES THE EMERGENCY LIGHTING THROUGHOUT THE BUILDING DURING DEMOLITION WORK, AS WELL AS RECONSTRUCTION WORK. PROVIDE ALL NECESSARY TEMPORARY LIGHTING, PARTITIONS, DUST COVERS, DROP COVERS, ETC. J. COORDINATE WITH CONTRACTOR FOR DEMOLITION WORK AND DISCONNECT LINE END OF CONDUCTORS WHICH ARE DIRECTLY AFFECTED BY DEMOLITION OR WHICH FEED EQUIPMENT. K. CUT, CAP AND FLUSH ALL ABANDONED STUBS, AND PROVIDE REQUIRED PATCHING. PROVIDE ABANDONED OUTLETS WITH BLANK COVER. L. PROVIDE BOX AND SPLICE WIRES WHERE IT IS REQUIRED TO MAINTAIN CONTINUITY OF CIRCUITS OR REMOVE WIRING AND SPLICE WIRE AT NEAREST ACTIVE BOX FROM OUTLETS WHICH HAVE BEEN TERMINATED. M. COORDINATE ALL WORK, SCHEDULING, ETC., WITH BUILDING OWNER.N. INCLUDE IN BID ALL DEMOLITION WORK AS REQUIRED TO COMPLETE ALL NEW WORK AS DELINEATED BY ARCHITECTURAL AND ENGINEERING DRAWINGS WHETHER SHOWN ON DRAWINGS OR NOT I.E.; COORDINATION OF ALL SUBCONTRACTORS WORK, ELECTRICAL, PLUMBING, HVAC, CUTTING, PATCHING, ETC. O. CUT ALL EXISTING WALLS/PARTITIONS ETC., AS REQUIRED FOR ALL ELECTRICAL, HVAC, PLUMBING AND SPRINKLER WORK, INCLUDE ALL PATCHING AND REFINISHING. P. CONTRACTOR IS TO REMOVE ALL MISCELLANEOUS ATTACHED ITEMS, BOARDS, SCREENS, TV'S, ETC. VERIFY DISPOSITION WITH OWNER AND EITHER RETURN TO OWNER OR DISCARD. Q. WHERE ATHC IS TO BE REMOVED: REMOVE ANY AND ALL GYPSUM BOARD CEILINGS, AND/ OR SOFFITS, IN THE AFFECTED AREA. R. ANY STAIR REMOVAL NOTES APPLY TO ENTIRE STAIR TO ITS TERMINATION, I.E.; AT ROOF OR AT SECOND FLOOR), WHETHER STATED OR NOT. S. ALL EXISTING POKE-THROUGH FITTINGS NOT BEING REUSED SHALL BE REMOVED. ALL CORE-DRILLED HOLES SHALL BE PATCHED. INSTALL NEW METAL DECKING, TACK WELD TO UNDERSIDE OF EXISTING DECK, POUR CONCRETE TO FINISH FLUSH WITH EXISTING CONCRETE FLOOR SLAB. T. SEE CONSTRUCTION PLANS & FURNITURE/ELECTRICAL PLANS FOR NEW POKE-THROUGH LOCATIONS. U. PRIOR TO THE START OF DEMOLITION, CONTRACTOR SHALL VERIFY THAT ALL WALLS AND SOFFITS TO BE REMOVED DO NOT CONTAIN PLUMBING OR ELECTRICAL RUNS FROM ABOVE OR BELOW. V. 2% PR O P E R T Y L I N E PROPERTY LINE 6" / 12" 6" / 12" 2%2% CRICKET NO ROOF CHANGES. EXISTING ROOF PLAN IS FOR REFERENCE ONLY 2% A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP As indicated PI N E S T R E E T A D U 2 A-4.2 ROOF PLANS Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 ELEVATION KEY NOTES 1 CEMENT PLASTER (STUCCO), SEE SPECIFICATIONS 2 FIBER CEMENT PANELS 3 STONE, SEE SPECIFICATION 4 SIDING, SEE SPECIFICATIONS 5 ROOFING, SEE ROOF PLAN 6 WOOD 7 ENTRY DOOR 8 LINE OF WEEP SCREED 9 ATTIC VENT, SEE DETAILS 10 SCREENED UNDERFLOOR VENT 6X14 11 HOSE BIB, RECESSED SUPPLY BOX, SEE SPECIFICATIONS 12 HOSE BIB, STANDARD 13 GUARDRAIL - MIN. 42" A.F.F. 14 SKYLIGHT 15 WATERPROOF ELECTRICAL OUTLET 16 PROVIDE NATURAL GAS SUPPLY 17 EXTERIOR LIGHT FIXTURE 18 GUTTER WITH DOWNSPOUT EXTERIOR ELEVATION NOTES CONTRACTOR TO FIELD VERIFY BUILDING HEIGHTS AND THE ALLOWABLE BUILDING ENVELOPE. INFORM ARCHITECT OF ANY DISCREPANCIES A CONTRACTOR TO COORDINATE FINISH SURFACE ELEVATIONS OF ALL HARDSCAPE WITH LANDSCAPE AND CIVIL DRAWINGS. INFORM ARCHITECT OF ANY DISCREPANCIES B AT STUCCO (CEMENT PLASTER), PROVIDE CONTINUOUS METAL WEEP SCREED AS REQUIRED BY CODE, SEC R703.6.2.1, SEE DETAILS C AT MECHANICALLY ATTACHED STONE AND BRICK, PROVIDE FLASHING AND MINIMUM 3/8" DIA. WEEP HOLES AT 30" MIN. O.C. AS REQUIRED PER SEC R703.7.2 D STONE INSTALLATION SYSTEM SHALL BE REVIEWED AND APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO INSTALLATION E ALL DIMENSIONS ARE TO FINISH UNLESS OTHERWISE NOTEDF CONTRACTOR SHALL PROVIDE MOCK-UPS OF ALL EXTERIOR FINISHES AND ASSEMBLIES FOR OWNER'S AND ARCHITECT'S REVIEW AND APPROVAL G STRUCTURE SHALL COMPLY TO LOCAL GOVERNING HIGH FIRE HAZARD SEVERITY ZONE AS REQUIRED H STUCCO 2-COAT CEMENT PLASTER (STUCCO) SMOOTH "SANTA BARBARA FINISH" 2-COAT CEMENT PLASTER (STUCCO) SMOOTH PLASTER FINISH PANELING A.FIBER BOARD CEMENT PANELS B.PAINTED WOOD / EXTERIOR MILLWORK TRIM A. DOUGLAS FIR B.EXTERIOR GRADE PAINT RAFTER TAILS A. DOUGLAS FIR B.EXTERIOR GRADE PAINT SAMPLES AND MOCK-UPS OF ALL EXTERIOR MATERIALS TO BE SUBMITTED FOR ARCHITECT REVIEW AND OWNER APPROVAL PRIOR TO FABRICATION AND INSTALLATION. EXTERIOR FINISH MATERIALS LEVEL 1 SUB (N) T.O. PLATE 8' - 0 1/2"1 8 FINISH GRADE LEVEL 2 SUB 1 A-6.1 103 (E) (E) (E) 23' - 10 1/2" MATCH EXISTING CASING ON ALL (N) WINDOWS WOOD FENCE ENCLOSURE FOR HVAC CONDENSER. MATCH EXISTING FENCES ON SITE. 307 304306 303 203 202 LEVEL 1 SUB (N) T.O. PLATE 1 8 FINISH GRADE PR O P E R T Y L I N E AD U S E T B A C K 4' - 0" LEVEL 2 SUB 101 101 102 2 A-6.1 8' - 0 1/2" 12 7 EGRESS EGRESS (E)302 LEVEL 1 SUB (N) T.O. PLATE 8' - 0 1/2" LEVEL 2 SUB 8' - 0 1/2" 23' - 10 1/2" 307 203 202 306 304 303(E) (E) LEVEL 1 SUB (N) T.O. PLATE 8' - 0 1/2" LEVEL 2 SUB PR O P E R T Y L I N E AD U S E T B A C K 4' - 0" 302 A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP As indicated PI N E S T R E E T A D U 2 A-6.0 ELEVATIONS Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 SCALE: 1/4" = 1'-0"EAST ELEVATION 2 SCALE: 1/4" = 1'-0"NORTH ELEVATION 1 SCALE: 1/4" = 1'-0"(E) EAST ELEVATION 4 SCALE: 1/4" = 1'-0"(E) NORTH ELEVATION 3 1 FOUNDATION, SEE STRUCTURAL PLANS 2 3" CONCRETE DUST SLAB 3 FLOOR JOIST, SEE STRUCTURAL PLANS 4 PLYWOOD SUB-FLOOR, SEE STRUCTRUAL 5 FINISH FLOOR ASSEMBLY, SEE ARCHITECTUAL DETAILS 6 BATT INSULATION, SEE TITEL 24 7 RIGID SPRAY ON INSULATION 8 5/8" TYPE "X" GYPSUM BOARD WITH VENEER PLASTER, SEE SPECIFICATIONS 9 SPECIALTY PLASTER FINISH, SEE SPECIFICATIONS 10 EXTERIOR CEMENT PLASTER (STUCCO), SEE SPECIFICATIONS 11 FIBER CEMENT PANELS 12 GUARDRAIL AT 42" ABOVE FINISH FLOOR 13 HANDRAIL AT 34" - 38" ABOVE FINISH FLOOR 14 CEILING JOIST, SEE STRUCTURAL PLANS 15 ROOF RAFTERS, SEE STRUCTURAL PLANS 16 ROOF SHEATHING, SEE STRUCTURAL PLANS 17 CLASS "A" ROOFING ASSEMBLY, SEE ROOF PLAN FOR SPECIFICATIONS 18 BELOW GRADE WATERPROOFING, SEE DETAILS AND SPECIFICATIONS SECTION KEY NOTES BUILDING SECTION NOTES CONTRACTOR TO FIELD VERIFY BUILDING HEIGHTS AND THE ALLOWABLE BUILDING ENVELOPE. INFORM ARCHITECT OF ANY DISCREPANCIES A. CONTRACTOR TO FIELD VERIFY BUILDING HEIGHTS AND THE ALLOWABLE BUILDING ENVELOPE. INFORM ARCHITECT OF ANY DISCREPANCIES B. PROVIDE A CONTINUOUS METAL WEEP SCREED AS REQUIRED BY CODE SECTION R703.6.2.1, SEE DETAILS C. AT MECHANICALLY ATTACHED STONE AND BRICK, PROVIDE FLASHING AND MINIMUM 3/8" DIA. WEEP HOLES AT 30" MIN. O.C. AS REQUIRED PER SEC R703.7.2 D. STONE INSTALLATION SYSTEM SHALL BE REVIEWED AND APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO INSTALLATION E. CONTRACTOR SHALL PROVIDE MOCK-UPS OF ALL EXTERIOR FINISHES AND ASSEMBLIES FOR OWNER'S AND ARCHITECT'S REVIEW AND APPROVAL F. ALL EXTERIOR STUDS SHALL BE 2X8 FRAMING OR MULTIPLE ROWS OF 2X6 FRAMING UNLESS OTHERWISE NOTED. ALL INTERIOR WALLS SHALL BE 2X6 FRAMING UNLESS OTHERWISE NOTED. SPACING AND SPECIFICATION ARE PER STRUCTURAL G PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON ALL GARAGE WALLS, CEILING, POSTS, AND SUPPORTING BEAMS AND SHALL EXTEND FROM TOP OF CONCRETE TO AND INCLUDING THE CEILING H PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS IN ENCLOSED USEABLE SPACE UNDER STAIRS I STRUCTURE SHALL COMPLY TO LOCAL GOVERNING HIGH FIRE HAZARD SEVERITY ZONE AS REQUIRED J FIRE BLOCKING SHALL BE PROVIDED IN WOOD-FRAMED CONSTRUCTION IN THE FOLLOWING LOCATIONS: K a. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS, VERTICALLY AT THE CEILING AND FLOOR LEVELS HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET b. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, AND COVE CEILINGS c. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN d. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVELINSULATION: PROVIDE R-19 MIN. AT ALL EXTERIOR WALLS, INCLUDING GARAGE. PROVIDE R-30 INSULATION IN ATTIC SPACES. PROVIDE R-19 INSULATION AT ALL INTERIOR WALLS. PROVIDE R-30 INSULATION AT ALL FLOOR FRAMING. SEE TITLE 24 FOR ADDITIONAL REQUIREMENTS. PROVIDE INSULATION AROUND PLUMBING PIPES AND HVAC DUCTS, SEE MECHANICAL AND PLUMBING PLANS FOR ADDITIONAL REQUIREMENTS L ATTIC INSULATION SHALL HAVE A VAPOR BARRIER WITH A TRANSMISSION RATE NOT EXCEEDING 1 PERM IN ACCORDANCE WITH ASTM E96 INSTALLED ON THE WARM SIDE OF THE ATTIC INULSATION M AN APPROVED WEATHERPROOFING CONSULTANT MUST CERTIFY THE WEATHERPROOFING ELEMENTS OF THE BUILDING HAVE BEEN INSTALLED IN ACCORDANCE WITH THE APPROVED PLANS AS REQUIRED BY LOCAL CODES AND PER MANUFACTURER'S RECOMMENDATIONS N CONTRACTOR SHALL VERIFY WITH MECHANICAL. ELECTRICAL, AND PLUMBING PLANS ALL LOCATIONS OF MECHANICAL UNITS, DUCTS, REGISTERS, ELECTRICAL PANELS, ACCESS TO PLUMBING FIXTURES, ETC. OLEVEL 1 SUB (N) T.O. PLATE LEVEL 2 SUB 1 A-6.1 8' - 0 1/2" BEDROOM 1 104 LIVING / KITCHEN 102 6 FINISH GRADE 7 5 1 PROVIDE MIN 1HR/ STC 50 RATING LEVEL 1 SUB (N) T.O. PLATE LEVEL 2 SUB 2 A-6.1 LIVING / KITCHEN 102 BATHROOM 103 6 5 14 7 8' - 0 1/2" FINISH GRADE 1 PROVIDE MIN 1HR/ STC 50 RATING A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP As indicated PI N E S T R E E T A D U 2 A-6.1 SECTIONS Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 SCALE: 1/4" = 1'-0"CROSS SECTION 2 SCALE: 1/4" = 1'-0"LONG SECTION 1 5% SLOPE SEE CIVIL R-19 BATT INSULATION GRACE ULTRA LAP OVER WEEP SCREED FINISH GRADE 8" MIN. 2' - 0" UNDIST. GROUND 1' - 0" STUCCO OVER 2 LAYERS OF GRADE "D" PAPER UNDER LATH MIN 15/32" WOOD STRUCTURAL PANEL 26 GA. CORROSION RESISTANT WEEP SCREED PER R703.7.2.1 2X4 STUD WALL @16" O.C. (DF STUD GRADE MIN) 5/8" GYPSUM BOARD PANEL. MIN. 5/8" TYPE X AT FIRE RATED CONDITIONS 2X P.T. SILL CLR. 3" 4" MIN. FOUNDATION PER STRUCTURAL FOR (E) SLABS, INSTALL A LAYER OF REDGARD WATERPROOFING FLUID APPLIED VAPOR BARRIER. INSTALL PER MANUFACTURER'S SPECIFICATIONS. ESR 1413 PROVIDE WITH A TOPPING SLAB. SEE STRUCTURAL. FIRST FLOOR SUBFLOOR W.R. GRACE VYCOR SELF ADHESIVE FLASHING. DOOR 6" GALVANIZED METAL SILL PAN. TURN UP SIDES OF JAMB. RETURN 6" AT EXTERIOR WALL CONCRETE SLAB. EXPANSION JOINT 1 1/2"SLOPE W.R. GRACE VYCOR SELF ADHESIVE FLASHING. LAP OVER FLASHING. CEMENT STUCCO PLASTER. BATT INSULATION JAMB. PAINTED 2 LAYERS OF GRADE D BUILDING PAPER DOOR 2 1/2" 3/8" 1/2" DOOR HEAD HEIGHT. W.R. GRACE VYCOR SELF ADHESIVE FLASHING. LAP OVER FLASHING. GALVANIZED METAL FLASHING W/ DRIP EDGE CEMENT STUCCO PLASTER. BACKER ROD AND SEALANT BATT INSULATION 1' - 0" 2 LAYERS OF GRADE D BUILDING PAPER DOOR 1/2" SHIM AS REQUIRED 2 1/2" 1/2" WINDOW HEAD HEIGHT. W.R. GRACE VYCOR SELF ADHESIVE FLASHING. LAP OVER FLASHING. GALVANIZED METAL FLASHING W/ DRIP EDGE CEMENT STUCCO PLASTER. BACKER ROD AND SEALANT BATT INSULATION 1' - 0" 2 LAYERS OF GRADE D BUILDING PAPER VINYL WINDOW SHIM AS REQUIRED W.R. GRACE VYCOR SELF ADHESIVE FLASHING. LAP OVER FLASHING. CEMENT STUCCO PLASTER. BATT INSULATION 2 LAYERS OF GRADE D BUILDING PAPER SHIM AS REQUIRED W.R. GRACE VYCOR SELF ADHESIVE FLASHING. LAP OVER BUILDING PAPER CEMENT STUCCO PLASTER. BATT INSULATION 2 LAYERS OF GRADE D BUILDING PAPER ALUMINUM CLAD WOOD DOOR INTERIOR SILL. MATCH EXISTING 1' - 0" SHIM AS REQUIRED 5% SLOPE SEE CIVIL R-19 BATT INSULATION GRACE ULTRA LAP OVER WEEP SCREED FINISH GRADE 8" MIN. 2' - 0" UNDIST. GROUND 1' - 0" STUCCO OVER 2 LAYERS OF GRADE "D" PAPER UNDER LATH MIN 15/32" WOOD STRUCTURAL PANEL 26 GA. CORROSION RESISTANT WEEP SCREED PER R703.7.2.1 2X4 STUD WALL @16" O.C. (DF STUD GRADE MIN) 5/8" GYPSUM BOARD PANEL. MIN. 5/8" TYPE X AT FIRE RATED CONDITIONS 2X P.T. SILL CLR. 3" 4" MIN. FOUNDATION PER STRUCTURAL (N) SLAB. PLACE OVER A MINIMUM 2" SAND LAYER OVER A VAPOR BARRIER MEETING ASTMS 1745 (15 MILS) OVER A 2" SAND LAYER OVER A 4" THICK BASE OF 1/2" OR LARGER CLEAN AGGREGATE. A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP As indicated PI N E S T R E E T A D U 2 A-9.1 DETAILS Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 SCALE: 1 1/2" = 1'-0"DETAIL -SCREED @ (E) SLAB 1 SCALE: 3" = 1'-0"DETAIL -INSWING DOOR THRESHOLD 3 SCALE: 3" = 1'-0"DETAIL -INSWING DOOR JAMB 4 SCALE: 3" = 1'-0"DETAIL -INSWING DOOR HEAD 5 SCALE: 3" = 1'-0"DETAIL -WINDOW HEAD 8 SCALE: 3" = 1'-0"DETAIL -WINDOW JAMB 7 SCALE: 3" = 1'-0"DETAIL -WINDOW SILL 6 SCALE: 1 1/2" = 1'-0"DETAIL -SCREED @ (N) SLAB 2 02/10/2025 02/10/2025 02/10/2025 02/10/2025 A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP PI N E S T R E E T A D U 2 G-1.1 TITLE-24 Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP PI N E S T R E E T A D U 2 G-1.2 TITLE-24 Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP PI N E S T R E E T A D U 2 G-1.3 TITLE-24 Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP PI N E S T R E E T A D U 2 G-1.4 TITLE-24 Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP PI N E S T R E E T A D U 2 G-1.5 TITLE-24 Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP PI N E S T R E E T A D U 2 G-1.6 GREEN CODE Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 N/A N/A N/A N/A N/A A-0.0 SITE PLAN 423 E. PINE STREET, SANTA ANA, CA 92701 CONVERSIONS OF EXISTING GARAGES TO ADU. A-1.5 A-1.5 & A-1.6 A-1.5 N/A NO LANDSCAPE A-1.5 A-1.5 A-1.5 A-1.5 A-1.6 A-1.6 A-1.6 A-1.6 A-1.6 A-1.6 A-1.6 A-1.6 A-4.0 REDGARD ON (E) SLAB A-1.6 A-4.0 KEYNOTE 15 A-1.6 A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP PI N E S T R E E T A D U 2 G-1.7 GREEN CODE Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 X CONT X CONT X CONT X X X X X X X CONT X CONT X CONT X X CONT X CONT X CONT X CONT X CONT X CONT X CONT X A R C H I T E C T U R E D I A L E C T I C 80 1 S O U T H H O P E S T R E E T , S U I T E 9 1 7 | L O S A N G E L E S , C A L I F O R N I A 9 0 0 1 7 62 6 . 3 7 5 . 2 8 7 3 | W W W . D I A L E C T I C A R C H . C O M | D I A L E C T I C A R C H @ G M A I L . C O M REVISIONS ISSUE DATE: PROJECT #: DRAWN BY: CHECKED BY: SCALE: DIGITAL STAMP PI N E S T R E E T A D U 2 G-1.8 GREEN CODE Checker 2401.00 VF 03.12.2025 PERMIT SET 42 3 E P I N E S T & 4 2 3 P I N E S T . UN I T # E , S A N T A A N A , C A 9 2 7 0 1 X CONT X X CONT X CONT X CONT X CONT X CONT X X CONT X X X CONT X CONT X CONT X CONT X CONT X CONT X CONT X CONT X CONT X CONT SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org INTERIM CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall July 31, 2024 Also sent via email to: john93hernandez@gmail.com Martin Z. Hernandez 83516 Mecca Hills Avenue Coachella, CA 92236 Subject: Address Assignment for an Attached Accessory Dwelling Unit located at 423 East Pine Street (APN: 404-086-12) in Santa Ana, CA Dear Martin, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a garage-conversion ADU located at 423 East Pine Street (APN: 404-086-12). Notice is hereby given that the following assigned address shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address to be Activated/Posted To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. The address will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 664-2753 or by email at PRaj@santa-ana.org. Sincerely, Punkaj Raj Planning Technician Exhibit A – First Floor Address Plan Exhibit B – Second Floor Address Plan Address Letter for 423 East Pine Street Page 2 of 2 c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Mishele Richards, Orange County Fire Authority, GEO Files Coordinator Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager (E) MFD UNIT423 E PINE STREETUNIT A - FIRST FLOOR PINE STREET EXHIBIT A: ADDRESS PLAN - FIRST FLOOR (E) MFD UNIT423 E PINE STREETUNIT B LAUNDRY MECH.ROOM (E) ADU252 S. OAK STREET (N) ADU423 E PINE STREETUNIT E OA K S T R E E T (E) MFD UNIT423 E PINE STREETUNIT A - SECOND FLOOR (E) MFD UNIT423 E PINE STREETUNIT C (E) MFD UNIT423 E PINE STREETUNIT D PINE STREET OA K S T R E E T EXHIBIT B: ADDRESS PLAN - SECOND FLOOR O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR joh93hernandez@gmail.com “Structural Calculations” 2ND SUBMITTAL – 09/24 3RD SUBMITTAL – 02/25 ACCESSORY DWELLING UNIT Project Site: 423 E PINE ST. & 423 E PINE ST. UNIT #E SANTA ANA, CA 92701 CALCULATIONS BY: PEDRO D. HOYA CHECKED BY: FRANCISCO GARCIA, P.E - - - TEL. (323) 717-1303 600 W. MAIN ST. SUITE 200. ALHAMBRA CA, 91801 1/15 3 02/10/2025 TABLE OF CONTENTS 1) LOADING CONDITIONS ..................................................................... 3 2) FLOOR FRAMING LOADING ............................................................ 4 3) FLOOR FRAMING RESULTS .............................................................. 6 4) SEISMIC DESIGN AND DISTRIBUTION PER [ASCE7-16] ............. 7 5) WIND DESIGN PER [ASCE7-16] ......................................................... 10 6) LATERAL ANALYSIS .......................................................................... 11 7) DETERMINATION OF CONCRETE PADS ........................................ 15 2/15 3 3 02/10/2025 PROJECT SITE: 423 E PINE ST. SANTA ANA, CA 92701 DESIGN CRITERIA CODE: CALIFORNIA BUILDING CODE-2022 EDITION MATERIALS: • TIMBER - DOUGLAS FIR LARCH RAFTERS & JOIST - #2 GRADE BEAMS, HEADERS, & POSTS - #1 GRADE UNLESS OTHERWISE NOTED (U.N.O.) PLYWOOD - PS 1-95, PER APA STANDARD, PI. 32/16 • CONCRETE – F’c=2500 PSI @ 28 DAYS • REINFORCING STEEL - ASTM A-615 #4 AND SMALLER, GRADE 40 #5 AND LARGER, GRADE 60 • SOIL PRESSURE - 1,500 PSF PER [TABLE 1806.2] • LOADS - (EXTERIOR WALL) PSF FRAMING (2X4 @16") 1.9 PLYWOOD SHEATHING 1.5 STUCCO 8.0 INSULATION - R-13 1.5 1/2" GYP. BOARD 2.5 MISCELLANEOUS 0.6 TOTAL D.L. = 16 PSF (INTERIOR WALL) PSF FRAMING (2X4 @16") 1.9 INSULATION - R-13 1.5 1/2" GYP. BOARD 2.5 MISCELLANEOUS 2.1 TOTAL D.L. = 8 PSF WALL LOAD AVERAGE = (16+8)/2 = 12PSF (ROOF) PSF ROOFING MATERIAL 6.0 PLYWOOD SHEATHING 1.5 FRAMING 1.8 MISCELLANEOUS 1.2 TOTAL D.L. = 10.5 PSF L.L. = 20 PSF (ROOF) -VAULTED- PSF ROOFING MATERIAL 6.0 PLYWOOD SHEATHING 1.5 FRAMING 2.4 INSULATION- R-30 2.1 1/2" GYP. BOARD 2.5 MISCELLANEOUS 1.5 TOTAL D.L. = 16 PSF L.L. = 20 PSF (CEILING) PSF INSULATION - R-30 2.1 1/2" GYP. BOARD 2.5 FRAMING 1.9 MISCELLANEOUS 1.0 TOTAL D.L. = 7.5 PSF L.L. = 10 PSF (FLOOR) PSF FLOORING 3.0 PLYWOOD SHEATHING 2.5 FRAMING 2.4 INSULATION - R-19 1.8 1/2" GYP. BOARD 2.5 MISCELLANEOUS 1.8 TOTAL D.L. = 14 PSF L.L. = 40 PSF 3/15 4/15 pg.6 5/15 pg.6 Multiple Simple Beam ALONSO H. CORONELLic. # : KW-06005817 FJ Engineering Software copyright ENERCALC, INC. 1983-2020, Build:12.20.5.17 File: PINE_423_II_ENERCALC.ec6 Project Title:PINE 423 IIEngineer:K. CHAVEZProject ID: Printed: 10 FEB 2025, 3:07PM Project Descr: Description : BEAM Size :2x10, Sawn, Fully BracedUsing Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Douglas Fir-Larch No.29009001350625 1600580180575 31.21Eminbend - xx ksi Wood Species :Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psiFc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf FJ-1 Applied Loads Unif Load: D = 0.0140, L = 0.040 k/ft, Trib= 1.333 ft Point: D = 0.4155, Lr = 0.2450 k @ -3.0 ft .Design Summary Max fb/Fb Ratio =0.814 : 1 Max Reactions (k)HEWSLrL +D+Lr+HLoad Comb : Span # 1 Left Support D in 3.000 inft 78.96 psi Fb : Allowable :1,423.13 psi Right Support Fv : Allowable :Span # 1 Load Comb :+D+0.750Lr+0.750L+H225.00 psi fb : Actual : Max fv/FvRatio =0.351 : 1 2.235 ft 1,158.69 psi at atfv : Actual : Ratio 1770 Ratio 994 Max DeflectionsTransient Downward 0.104 in Transient Upward -0.052 in Total Downward 0.267 in Total Upward -0.121 in 0.70 0.45 0.32-0.04 0.24 -0.07 Ratio 688 268Ratio LC: Lr Only LC: +D+Lr+H LC: L Only LC: +D+Lr+H BEAM Size :4x8, Sawn, Fully UnbracedUsing Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Douglas Fir-Larch No.1100010001500625 1700620180675 31.21Eminbend - xx ksi Wood Species :Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psiFc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf BM-1 Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.5250, Lr = 0.240, L = 0.3375 k/ft, Trib= 1.0 ft .Design Summary Max fb/Fb Ratio =0.822 : 1 Max Reactions (k)HEWSLrL +D+L+HLoad Comb : Span # 1 Left Support D in 2.500 inft 97.49 psi Fb : Allowable :1,290.97 psi Right Support Fv : Allowable :Span # 1 Load Comb :+D+L+H180.00 psi fb : Actual : Max fv/FvRatio =0.542 : 1 4.400 ft 1,061.59 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max DeflectionsTransient Downward 0.025 in Transient Upward 0.000 in Total Downward 0.072 in Total Upward 0.000 in 1.33 0.84 0.601.33 0.84 0.60 Ratio 2376 832Ratio LC: L Only LC: +D+0.750Lr+0.750L+H LC:LC: 6/15                   !       "#  !$%&'(')%*'&+',-.'$/01)23)40245043+56-7893:)5;42/2<=13;>0?/2<=1@..A7,.BC-B3D997ACB-.6. *421 EFEGFEHEIIJKLJMINO*1P/?0+>=1(1Q1R10S1*>S<T102 UVWGXYZ(/P[+421?>R\]])/21+^4PP _X_`  YY!I!Mab\c1 d4^<1 *1PSR/c2/>0Y!ELL OVWe   !` H!E    aY H!IKf OVWe   !` Y!H  aOY!KIK  X         OY X  YY!I!L  X         _Y!HM g      H!E  U_Y X  YY!I!L g      Y!H  Ub\c1 d4^<1 *1PSR/c2/>0_V X  YY!I!L       hiY!E       H!E  i X  YY!I!L       Y!H  NU H!KIM OVW"     iNU Y!E       NUNUO H!ZKY     "     jk L kX          ej Y!ELL N     "X     !`H!E  al Y!MLE i     Xm `En   h#    KHh a     _Y!K i            !`H!E  aYej H!IKf N     "X     !`Y!H  aYl H!IfZ i     Xm `En   h#    KHh a     !Y_H!Z i            !`Y!H  aNU H!KfY i            !`N"  U   aNUl H!KIM   Xm `En   h#    KHh aN"  U   VeH!fMY O   "     VeY H!fEZ O   "    YVo Y!MKL o    7/15 II r =Wo = 8/15 r Cs = 0.2061 k= 1.0 LEVEL WEIGHT TOTAL Vx Hx MOMENT %Fx S Fx WEIGHT Vx = CsW V x Hx k Vx Hxk SVx (%) S(Vx Hxk) ( R ) ( W ) ROOF 16 psf + 6 psf 22.0 psf 4.53 psf 17.0 ft 77.08 lb-ft 0.64261 6.36 psf 6.36 psf (wall) 12 psf ( W ) ( F ) ( W ) FLOOR 6 psf + 14 psf+6 26 psf 5.36 psf 8.0 ft 42.87 lb-ft 0.35739 3.54 psf 9.89 psf SUM: ( S )9.89 psf 119.95 lb-ft 1.0 9.89 lb-ft VROOF =6.36 psf VFLOOR =3.54 psf VALL =9.89 psf 9/15 WIND DESIGN Based on ASCE 7-16 [Ch. 28] WIND DESIGN [28.5] Method 2: Enclosed Simple Diaphragm Low-Rise Buildings DESIGN CRITERIA: RISK CATEGORY =II WIND SPEED, V = 110 MPH EXPOSURE = B ROOF SLOPE =0 θ=0.00 ROOF HEIGHT, h =17.5 FT (max) NET PRESSURE: p s =λ K zt p S30 (EQ. 28.5-1) θ h ZONE A (WALL) ZONE B (ROOF) END ZONE D p s =λ K zt p S30 (EQ. 28.5-1) λ = 1.00 ADJUSTMENT FACTOR [FIG. 28.5-1] K zt =1.0 TOPOGRAPHIC FACTOR (p S30 )A=19.2 PSF - ZONE A, WALL END ZONE [FIG. 28.5-1] ~ WORST CASE ~ (p S30 )D=-5.9 PSF - ZONE D, ROOF END ZONE [FIG. 28.5-1] (p S )A=1.00 1.0 19.2 19.20 PSF (p S )D=1.00 1.0 -5.9 -5.90 PSF THEREFORE: (p S )A=19.20 11.52 PSF {PER 28.5.4} Zone A (p S )D=-5.90 -3.54 PSF {PER 28.5.4} Zone D (ASD LOAD COMBINATION FACTOR FOR WIND) < 16 PSF MIN. < 8 PSF MIN. 0.6 *( ) = ( ) ( )( PSF) = 0.6 *( ) = ( ) ( )( PSF) = 10/15 WIND ZONES PINE 423 (II) PROJECT LATERAL DESIGN PsA 16psf:=Zone A PsD 8psf:=Zone D ________________________________________________________________________________________ SEISMIC @ ROOF LEVEL ON LINE ( A ) Vall 9.89 psf= VS Vall 24 ft29.5 ft 2 :=VS 3501.1 lb=- - CONTROLS - - WIND Tributary Width Between Supports Zone A (wall) Zone D (roof) PsA 16 psf=Hw 17 ft=PsD 8 psf=Hr 0 ft=W 29.5ft 0ft+:= VW PsA Hw 2  PsD Hr( )+  W 2  :=VW 2006 lb= SHEARWALL DESIGN Lw 8ft 0ft+:=Lw 8 ft= VS 3501.1 lb= Seismic controls υs VS Lw :=υs 437.63 lb ft=< 550 lb/ft USE S.W. = 4 OVERTURNING Lmin 8ft:=H 8ft:=SDS 1.03= OTM υs( )Lmin( )H( ):=OTM 28008.48 lb ft= Wall RM 12psf H( ) Lmin( )2 2:=RM 3072 lb ft= USE SIMPSON "HDU4" HOLDOWNT OTM 0.9 0.2SDS-()RM- Lmin :=T 3234.56 lb= ANCHOR BOLTS :> USE 5/8" f X L= 12" @ 24" O.C. ________________________________________________________________________________________ 11/15 SEISMIC @ ROOF LEVEL ON LINE ( B ) Vall 9.89 psf= VS Vall 24 ft29.5 ft 2 27 ft8 ft 2 + :=VS 4569.2 lb=- - CONTROLS - - WIND Tributary Width Between Supports Zone A (wall) Zone D (roof) PsA 16 psf=Hw 17 ft=PsD 8 psf=Hr 0 ft=W 29.5ft 8ft+:= VW PsA Hw 2  PsD Hr( )+  W 2  :=VW 2550 lb= SHEARWALL DESIGN Lw 8ft 4ft+:=Lw 12 ft= VS 4569.2 lb= Seismic Controls υs VS Lw :=υs 380.77 lb ft=< 410 lb/ft USE S.W. = 3 OVERTURNING Lmin 4ft:=H 8ft:=SDS 1.03= OTM υs( )Lmin( )H( ):=OTM 12184.48 lb ft= Wall RM 12psf H( ) Lmin( )2 2:=RM 768 lb ft= USE SIMPSON "HDU4" HOLDOWNT OTM 0.9 0.2SDS-()RM- Lmin :=T 2912.87 lb= ANCHOR BOLTS :> USE 5/8" f X L= 12" @ 32" O.C. ________________________________________________________________________________________ 12/15 SEISMIC @ ROOF LEVEL ON LINE ( 1 ) Vall 9.89 psf= VS Vall 37 ft24 ft 2 :=VS 4391.2 lb=- - CONTROLS - - WIND Tributary Width Between Supports Zone A (wall) Zone D (roof) PsA 16 psf=Hw 17 ft=PsD 8 psf=Hr 0 ft=W 24ft 0ft+:= VW PsA Hw 2  PsD Hr( )+  W 2  :=VW 1632 lb= SHEARWALL DESIGN Lw 7ft 0ft+:=Lw 7 ft= VS 4391.2 lb= Seismic Controls υs VS Lw :=υs 627.31 lb ft=< 820 lb/ft USE S.W. = 6 OVERTURNING Lmin 7ft:=H 8ft:=SDS 1.03= OTM υs( )Lmin( )H( ):=OTM 35129.28 lb ft= Wall RM 12psf H( ) Lmin( )2 2:=RM 2352 lb ft= USE SIMPSON "HDU8" HOLDOWNT OTM 0.9 0.2SDS-()RM- Lmin :=T 4785.28 lb= ANCHOR BOLTS :> USE 5/8" f X L= 12" @ 16" O.C. ________________________________________________________________________________________ 13/15 SEISMIC @ ROOF LEVEL ON LINE ( 2 ) Vall 9.89 psf= VS Vall 37 ft21 ft 2 32 ft20 ft 2 + :=VS 7007.1 lb=- - CONTROLS - - WIND Tributary Width Between Supports Zone A (wall) Zone D (roof) PsA 16 psf=Hw 17 ft=PsD 8 psf=Hr 0 ft=W 21ft 20ft+:= VW PsA Hw 2  PsD Hr( )+  W 2  :=VW 2788 lb= SHEARWALL DESIGN Lw 16ft 0ft+:=Lw 16 ft= VS 7007.1 lb= Seismic Controls υs VS Lw :=υs 437.94 lb ft=< 550 lb/ft USE S.W. = 4 OVERTURNING Lmin 16ft:=H 8ft:=SDS 1.03= OTM υs( )Lmin( )H( ):=OTM 56056.52 lb ft= Wall RM 12psf H( ) Lmin( )2 2:=RM 12288 lb ft= USE SIMPSON "HDU4" HOLDOWNT OTM 0.9 0.2SDS-()RM- Lmin :=T 2970.54 lb= ANCHOR BOLTS :> USE 5/8" f X L= 12" @ 24" O.C. ________________________________________________________________________________________ 14/15 DE T E R M I N A T I O N O F C O N C R E T E P A D S PR O J E C T # P I N E _ 4 2 3 SO I L B E A R I N G CO N C . W T H (P S F ) (L B / F T 3) (F T ) 15 0 0 15 0 1 AC T U A L D I M . U S E D D I M . BE A M # DE A D L I V E S E I S M I C T O T A L C O N C R E T E P A D C O N C R E T E P A D SW L I N E 1 0 l b 0 l b 4 7 8 6 l b 4 7 8 6 l b 1. 8 8 f t 2. 0 S Q f t → TH E R E F O R E U S E ( 3 ) # 4 R E B A R E A C H W A Y TO T A L R E A C T I O N w P v  s o i l Co n c wt h      15/15 3 A .0 i r T r Number of Square Feet Of Residential Space dumber of Square Feet of Commercial Space ---- ]he above representati CITY OF SANTA-rANA Planning and Building Agency Ap roved C146 1f'Catc of COMpliancc FOR � ISSUAN( RY111clit of School Facility,,FC�'s S#flnt:i ikna U111 I School Districtrict74 Sqo Ft x $ (Dev. Fee) Sq.Ft x $_ (Dev. Fee) renresentatlOri5 as to square 40 footage are true. Applicant ons are not true, then this certificate shal notified. App licant is hereby notice Government Code Section 53080 mus Applican Sl*gnatur me (Please Print) This certifies that t erections of the Governmen L)IS TRIAR U 71 ON f eleptiOrle IL elephone Total $ Total s- •e. CITti dF �Y 4r AV r A) r agrees that if it is later determined that such � �L., ap ...«.....-intoC;t.,/C`nimty shal a,�tnmatically terminate, anu �nC �,����►a�•� «,---��..-: __--- that any party tiling a protest regarding the imposition of tees t do so within 90 days from the payment of the fAe. he above -named Applicant has paid scho�facility t Code and Education ode. eiDresentat*Ive fees in comp W111-It? -City/County Applicant Pink,, Facilities r 25 Date l be pursuant to Hance with all existin and apPl���b�z ZZ Date it M L F �J 6 x f � , F Page 1 of 1 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2022 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 Rigid Conduit Service Entrance Conductor Riser Underground Service Lateral METER Rev. 1/21/2020