HomeMy WebLinkAbout401 W Jonquil Rd & Unit# 2 - PlanGENERAL INFOMATION 401 W JONQUIL RD, SANTA ANA, CA 92706 AGENCY REQUIREMENTS -JURISDICTION HAVING AUTHORITY:401 W JONQUIL RD, SANTA ANA, CA 92706 -LEGAL DESCRIPTION:TRACT NO 1471 LOT 32 -ASSESSOR'S IDENTIFICATION No (AIN):002-037-32 -IN FLOOD ZONE FEMA SHFA'S:FLOOD ZONE X-0602320163J -CONSTRUCTION TYPE:V-B -ZONING:R1 -BUILDING CLASSIFICATION:SINGLE FAMILY RESIDENTIAL -OCCUPANCY GROUP:R3 -SPRINKLERS:EXISTING MAIN HOUSE: NO, ADU: NO -NUMBER OF STORIES:1 STORIES (MAIN HOUSE AND ADU) -ADU MAX HEIGHT:16'-03" (ALLOWABLE: 20') -PROVIDED ADU SETBACKS: FRONT SETBACK: SIDE: REAR: DISTANCE TO (E) DWELLING: DISTANCE TO (E) GARAGE: OPEN SPACE: SETBACKS INDICATE REQUIRED MINIMUM DISTANCE FROM PROPERTY LINES. CONTRACTOR TO VERIFY ON SITE. NOTE: REFER TO TOPOGRAPHIC & BOUNDARY SURVEY PLAN FOR LEGAL SETBACK AND EASEMENT. THE CURRENT PREVAILING BUILDING AND CONSTRUCTION CODES ARE AS FOLLOWS:  2022 CALIFORNIA BUILDING CODE  2022 CALIFORNIA RESIDENTIAL CODE  2022 CALIFORNIA FIRE CODE  2022 CALIFORNIA MECHANICAL CODE  2022 CALIFORNIA ELECTRICAL CODE  2022 CALIFORNIA PLUMBING CODE  2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS  2022 CALIFORNIA GREEN BUILDING STANDARDS CODE -REGULATION OF THE STATE AND LOCAL FIRE MARSHALS & CITY ORDINANCE. -CITY OF SANTA ANA AMENDMENTS AND MUNICIPAL CODE. APPLICABLE CODE LEGAL JURISDICTION : CITY OF SANTA ANA, CA 92706 VICINITY MAP NOTES -THE PLANS FOR SINGLE FAMILY DWELLINGS AND DUPLEXES ARE NOT CHECKED FOR ELECTRICAL, MECHANICAL, AND PLUMBING CODE COMPLIANCE AND THESE DISCIPLINES ARE SUBJECT TO FIELD INSPECTION AND APPROVAL BY THE INSPECTOR. -ALL DOORS & WINDOWS SHALL MEET SANTA ANA SECURITY ORDINANCE. -SEPARATE PERMITS REQUIRED FOR PROPOSED SITE IMPROVEMENT SHOWN ON THE SITE PLAN SUCH AS UTILITY LINES FOR NEW FIRE PIT AND OUTDOOR KITCHEN AND NEW RAILING ON EXISTING CANTILEVER CONCRETE DECK. -THE SOLAR PERMIT ISSUANCE IS REQUIRED PRIOR TO PERFORM FRAMING INSPECTION. A MINIMUM 2.39 KW DC RESIDENTIAL SOLAR PV SYSTEM IS REQUIRED PER ENERGY PRESCRIPTIVE OR PERFORMANCE APPROACH AND UNDER SEPARATE PERMIT. -PROPOSING TO INSTALL A NEW WATER SERVICE AND METER OR SEWER LATERAL TO SERVE THE PROJECT SITE, THE CONSTRUCTION OF ANY PROPOSED WATER AND SEWER FACILITIES IN THE PUBLIC RIGHT-OF-WAY MUST BE SUBMITTED FOR A FORMAL PLAN CHECK REVIEW THROUGH PUBLIC WORKS PRIOR TO THE ISSUANCE OF AN ENCROACHMENT PERMIT. SCOPE OF WORK -MAIN HOUSE: EXISTING: 1,257 SF LIVING - 3 BEDS - 1 BATH - 1 POWDER. PROPOSED: CONVERTING A POWDER ROOM INTO A FULL BATHROOM BY RELOCATING/SHIFTING THE SINK AND TOILET TO ADD A SHOWER. -NEW DETACHED ADU: THE DETACHED ADU (981 SF) WILL HAVE THREE (3) BEDROOMS, TWO (2) BATHROOMS, A LAUNDRY CLOSET, AND A COMBINED LIVING AND KITCHEN AREA. A SEPARATE WATER HEATER AND A/C CONDENSER WILL SERVICE THE ADU UNIT. THE WATER HEATER WILL BE LOCATED IN AN INTEGRATED CLOSET. SHEET INDEX ARCHITECTURAL A0.00 COVER SHEET PROPOSED ADU ELECTRICAL & EQUIPMENT REFLECTED CEILING PLAN STRUCTURAL GENERAL STRUCTURAL NOTES S0.1 TYPICAL DETAILS TITLE 24 T24-1 TITLE 24 15' (ALLOWABLE: 15') PROVIDED EXISITING SETBACK ON PLAN DIRECTORY OWNER: -CONTACT: TIEN NGUYEN -ADDRESS: 401 W JONQUIL RD, SANTA ANA, CA 92706 -PHONE:(714) 715 9932 -EMAIL:knguyen@adkbancorpinc.com PROJECT DESIGNER: -CONTACT: BUI DO -ADDRESS: 5581 DANNY AVE, CYPRESS, CA 90630 -PHONE:(714) 677 7069 -EMAIL:dobuihuylinh@gmail.com STATISTICS ZONING R1 PROPERTY AREA 7,765 sq. ft. EXISTING - MAIN HOUSE LIVING AREA 1,257 sq. ft. DETACHED GARAGE (2-CARS)368 sq. ft. PORCH (Overhangs Over 30")65 sq. ft. TOTAL 1 1,690 sq. ft. PROPOSED - NEW ADU LIVING AREA 981 sq. ft. PORCH (Overhangs Over 30")0 sq. ft. TOTAL 2 981 sq. ft. BUILDING COVERAGE (Allow 35%) (TOTAL 1 + TOTAL 2) ÷ PROPERTY AREA X 100 34.40 % PROJECT DATA 1,476 SF (ALLOWABLE: Min 1,200 SF) 8' (ALLOWABLE: 5') 6' - 4 (ALLOWABLE: 4') 5' (ALLOWABLE: 4') Note: minimum dimension of 15'x15' continuous open space. -NEW ADDRESS FOR ADU: 401 W JONQUIL RD, UNIT 2, SANTA ANA, CA 92706. EXISTING PRIMARY DWELLING - WESTERN VIEW EXISTING PRIMARY DWELLING - SOUTHERN VIEW EXISTING PRIMARY DWELLING - EASTERN VIEW N A0.01 RESIDENTIAL MANDATORY MEASURES - SHEET 1 A0.02 RESIDENTIAL MANDATORY MEASURES - SHEET 2 A1.02 EXISTING - PROPOSED SITE PLAN A1.04 EXISTING ROOF PLAN A2.01 NEW ADU - FLOOR PLAN AND ROOF PLAN A2.03 NEW ADU - ELEVATIONS - SECTIONS ARCHITECTURAL DETAILSA2.06 A4.00 A1.06 EXISTING MAIN HOUSE - PROPOSED BATHROOMHOME TOP HOME: STRUCTURAL, T24. -CONTACT: TUNG VO -ADDRESS: 16168 Beach Blvd,Ste. 201 C, Huntington Beach, CA 92647. -PHONE:(714) 928 2006 -EMAIL:tungcivil2018@gmail.com S0.0 S1.0 FOUNDATION PLAN FRAMING PLAN STRUCTURAL DETAILSSD1 STRUCTURAL DETAILSSD2 CIVIL D-01 SITE DRAINAGE PLAN - GRADING EXEMPTION FORM LAN PHAM,P.E: CIVIL PLAN - SOIL REPORT October 18, 2024 - Project No. SA-02-09-24 -CONTACT: LAN PHAM -ADDRESS: 13139 HARBOR BLVD., GARDEN GROVE, CA 92843 -PHONE:(714) - 414 9215 -EMAIL:Lanpham9@hotmail.com DEVERLOPMENT FEE CALCULATION: ADU sf / SFD sf = 981 sf / 1,257 sf = 0.78 NOTES: THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN "SFD SF" OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN "SFD SF". DELTA DATE DESCRIPTION MA I N H O U S E R E M O D E L - B A T H R O O M 40 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 NE W A D U 40 1 W J o n q u i l R d , U n i t 2 , S a n t a A n a , C A 9 2 7 0 6 5/1/2025 DATE SIGNED: ARCHITECTURE Bldg #'s 101123019-20 APPROVALS: PLNG - C. Santana BLDG - W. Lee POLICE- B. Martin PUBLIC WORKS - B. Sarlak 1 EXISTING SITE PLAN 1/8"=1'-0" N POWER LIN E A B O V E SHALL BE INSTALLE D U N D E R G R O U N D (E) POWER POLE (E) EM (E) GM 6 F T . E A S E M E N T F O R P A C I F I C T E L E P H O N E A N D T E L E G R A P H . 10 F T . E A S E M E N T F O R S O U T H E R N C A L I F O R N I A E D I S O N . REF. DW DN.-19 DN.-12 FIRE PLACE (E) POWDER 1 23 4 5 6 6 6 2 2 7 7 U2 10 11 M1 8 4'-7" EXIST. 7' - 7 " EX I S T . 9 1 U3 PROPOSED 981 SF ADU (NOT INCLUDED THE PORCH) U1 (N) GM S = 2%S = 2%S = 2%S = 2% S = 2 % S = 2 % S = 2 % S = 2%S = 2% S = 2 % S = 2 % S = 2 % S = 2% S = 2% S = 2% S = 2 % Mi n . S = 5 % Mi n . S = 2 % Mi n . S = 5 % Mi n . S = 2 % Mi n . S = 5 % Mi n . S = 2 % Mi n . S = 5 % Mi n . S = 5% Min. S = 5% Min. S = 5% Min. S = 5% Min. S = 2% Min. S = 2% Min. S = 2% Min. S = 2 % Mi n . S = 1 % Mi n . S = 2 % Mi n . S = 1 % Mi n . S = 2% Min. S = 5% Min. S = 2% Min. S = 5% Min. S = 2% Min. S = 5% Min. S = 5 % Mi n . S = 5 % Mi n . S = 5 % Mi n . N (E) POWER POLE (E) GM 6 F T . E A S E M E N T F O R P A C I F I C T E L E P H O N E A N D T E L E G R A P H . 10 F T . E A S E M E N T F O R S O U T H E R N C A L I F O R N I A E D I S O N . (N) BATH 2 2 PROPOSED SITE PLAN 1/8"=1'-0" 8 15'-0" B.S.D 4' - 6 " EX I S T I N G 13 ' - 9 " E X I S T I N G 20'-0" EXISTING FRONT YARD 3' - 9 " F. S . D 30'-6" ADU 24 ' - 9 " 35 ' - 3 " A D U 2 4'-7" EXIST. 7' - 7 " E X I S T . 40'-0" EXISTING DWELLING 12 ' - 0 " EX I S T I N G DW E L L I N G 29 ' - 9 " EX I S T I N G DW E L L I N G 28'-0" EXISTING DWELLING 41 ' - 9 " EX I S T I N G DW E L L I N G 12'-0" EXISTING DWELLING 20'-2" EXISTING GARA G E 18 ' - 3 " E X I S T I N G G A R A G E 10 ' - 1 0 " E X I S T I N G 10 ' - 4 " E X I S T I N G 15'-10 1/2" TO (E) BLOCK WALL 16'-6" TO (E) BLOCK WALL 15 ' - 0 " F O R O P E N S P A C E 5' - 0 " SE T B A C K 8 U7 368 SF 1,257 SF 63 SF 1,202 SF OPEN SPACE 21'-3" BATH 2 BATH 1 W/D WH BEDROOM 1 BEDROOM 2 BEDROOM 3 DINING LIVING REF. KITCHEN PANTRY -1.5"2% Min. 18' X 9' PARKING SPACE FOR ADU U4 U6 5' - 2 " F. S . D U5 U8 10 ' - 6 " 4'-0" 8' - 6 " 10'-5" 31'-5" DISTANCE FOR OPEN SPACE 43 ' - 1 1 / 2 " F O R O P E N S P A C E 27'-0" FOR OPEN SPACE 16 ' - 6 " F O R O P E N S P A C E 28 ' - 6 " F O R O P E N S P A C E 2' - 1 " (E) 23'-11" (E ) 1 ' - 1 0 " REF. DW DN.-19 DN.-12 FIRE PLACE 18' X 9' PARKING SPACE FOR DWELLING 18' X 9' PARKING SPACE FOR DWELLING 21 1'-0" OHG 32'-6" 1'-0" OHG F.S.L 20'-2" NO OPENING O N W A L L 1.Hr WALL + EAVE 1.Hr EAVE 1.Hr WALL+EAVE M2 2' - 4 " F. S . D 2'-6" OHG. 1' - 0 " OH G . 1 A2.06 U9 U10 M3 1 A2.06 12 U11U12 EXISTING 2x WALL TO REMAIN NEW 2x WALL AREA NOT IN SCOPE OF WORK NEW 2x RATED WALL EXISTING 2x RATED WALL 1 EXISTING TO BE DEMOLISHED. EXISTING CONCRETE DRIVEWAY. 2 EXISTING LANDSCAPE. 3 EXISTING CONCRETE STREET CURB. 4 EXISTING PAVEMENT WALKWAY. 5 EXISTING CONCRETE SIDEWALK. 6 EXISTING 6'H. BLOCK WALL TO REMAIN. 7 EXISTING GATE TO BE RELOCATE. 8 EXISTING 100 AMP ELECTRICAL PANEL LOCATION. 9 EXISTING GAS METER LOCATION. 10 3' EXISTING VINYL FENCE 11 6' EXISTING WOOD FENCE M1 EXISTING A/C CONDENSER OF THE MAIN HOUSE. LINE OF ROOF ABOVE. OPEN SPACE AREA ORGANIC LIVING PLANT MATERIAL TREE. U4 NEW DUAL ELECTRICAL PANEL 200 AMP. U7 NEW GAS METER LOCATION. U1 EXISTING WATER METER. U5 NEW 100AMP ELECTRICAL SUB-PANEL FOR ADU. U6 NEW 100AMP ELECTRICAL SUB-PANEL FOR MAIN HOUSE. U8 SOLAR PANEL SYSTEM. FIRE SEPARATION LINE (IMAGINARY PROPERTY LINE) F.S.L FIRE SEPARATION DISTANCEF.S.D 1HR FIRE RATED EXTERIOR WALL AND/OR EAVE PROJECTION. REFER TO DETAILS A ON SHEET A2.06 1.Hr WALL + EAVE U2 U3 MULTI ZONE SPLIT SYSTEM AC. HEAT PUMP HEATING FACILITY ON PLAN TO MATCH WITH T-24 ENERGY CALCULATION. REFER TO SHEET A4.00 M2 U9 ELECTRICAL UNDERGROUND INSTALLATION REQUIREMENTS U10 GAS PIPING UNDERGROUND INSTALLATION REQUIREMENTS. M3 NEW WATER HEATER WITHIN PLASTER ENCLOSURE WITH LOUVER DOOR. PAINTED TO MATCH ADU EXTERIOR WALL. BUILDING SEPARATION DISTANCE.B.S.D 12 PROVIDE CONCRETE LANDING AS SHOWN ON PLAN. LANDING SHALL BE MIN. 3' ON EGRESS DIRECTION. U11 SEWER LINE TO TIE TO 4" LINE AT FRONT YARD . MINIMUM SLOPE 1/4"/12". U12 ADU WATER LINE CONNECTED TO EXISTING 1" WATER LINE AT THE FRONT YARD. NOTE:PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFORMING ALL EXISTING UTILITY EASEMENTS AND/OR CLEARANCE ON-SITE THAT MAY AFFECT THE PROJECT. DELTA DATE DESCRIPTION MA I N H O U S E R E M O D E L - B A T H R O O M 40 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 NE W A D U 40 1 W J o n q u i l R d , U n i t 2 , S a n t a A n a , C A 9 2 7 0 6 3/19/2025 DATE SIGNED: ARCHITECTURE (E)6:12 (E ) 6 :1 2 (E ) 6 :1 2 (E ) 6 :1 2 (E ) 6 :1 2 (E ) 6 :1 2 (E ) 6 :1 2 (E)6:12 43'-0" EXISTING DWELLING ROOF 16 ' - 0 " EX I S T I N G DW E L L I N G RO O F 30'-0" EXISTING DWELLING ROOF 44 ' - 9 " EX I S T I N G DW E L L I N G RO O F 28 ' - 9 " EX I S T I N G DW E L L I N G RO O F 2'-0" (E) OH. 21 ' - 3 " EX I S T I N G GA R A G E RO O F EXISTING MAIN HOUSE EXISTING GARAGE 1' - 0 " (E ) O H . 1'-0" (E) OH. 2' - 0 " (E ) O H . 22'-2" EXISTING GARAGE ROOF 1' - 0 " (E ) O H . 1 2 3 1 2 3 1'-0" (E) OH. 1' - 0 " (E ) O H . 1'-0" (E) OH. 2' - 0 " (E ) O H . LINE OF WALLS BELOW ROOF SLOPE PER PLAN SHINGLES ROOF - REFER TO EXTERIOR MATERIAL SPECIFICATIONS. EDGE OF ROOF EXTERIOR WALL BELOW. SYMBOLS GENERAL NOTES ROOF RIDGE. SHINGLES ROOF: LAMINATE ARCHITECTURAL ROOFING SHINGLES, GRAY COLOR. FIRE RATING (UL 790) CLASS A. ICC ESR-1389. INSTALLATION: OVER LAYERS UNDER-LAYMENT OVER PLYWOOD SHEATHING PER MANUFACTURE DIRECTION. EXTERIOR MATERIAL SPECIFICATIONS 1 2 3 A.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. B.NEW ROOFING, "CLASS A" FIRE RETARDANT INSTALLED OVER MIN. (2) LAYERS OF 30LBS FELT UNDER-LAYMENT OVER PLYWOOD SHEATHING PER MANUFACTURE DIRECTION. C.ROOF INSULATION TO BE R-30. INSULATION SHALL CONFORM TO FLAME-SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF 2022 CBC. D.OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION. E.VENT OPENINGS SHALL HAVE CORROSION RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL WITH 1/16" MIN. AND 1/8" MAX. OPENINGS. F.NOT MORE THAN 50% OF THE VENTS SHALL BE LOCATED NOT MORE THAN 3 FEET BELOW THE RIDGE. G.PROVIDE MIN. 24 GAUGE GALVANIZED SHEETING FOR ALL EXTERIOR FLASHING& WEATHER STRIPPING APPLICATIONS. DELTA DATE DESCRIPTION MA I N H O U S E R E M O D E L - B A T H R O O M 40 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 NE W A D U 40 1 W J o n q u i l R d , U n i t 2 , S a n t a A n a , C A 9 2 7 0 6 3/19/2025 DATE SIGNED: ARCHITECTURE N1EXISTING ROOF PLAN - MAIN HOUSE 1/4"=1'-0" 6 12 TOP OF RIDGE +17'-0" TOP OF PLATE 9'-6" INTERIOR FINISH FLOOR 1'-6" GRADE LEVEL 0'-0" 1 EXISTING MAIN HOUSE - SOUTH WEST ELEVATION 3/16"=1'-0"(NO CHANGES) 7 8 9 10 11 2 EXISTING MAIN HOUSE - SOUTH EAST ELEVATION 3/16"=1'-0" 6 12 TOP OF RIDGE +17'-0" TOP OF PLATE 9'-6" INTERIOR FINISH FLOOR 1'-6" GRADE LEVEL 0'-0" (NO CHANGES) 10 7 8 11 6 12 TOP OF RIDGE +17'-0" TOP OF PLATE 9'-6" INTERIOR FINISH FLOOR 1'-6" GRADE LEVEL 0'-0" 3 EXISTING MAIN HOUSE - NORTH EAST ELEVATION 3/16"=1'-0"(NO CHANGES) 11 8 7 10 6 12 TOP OF RIDGE +17'-0" TOP OF PLATE 9'-6" INTERIOR FINISH FLOOR 1'-6" GRADE LEVEL 0'-0" 4 EXISTING MAIN HOUSE - NORTH WEST ELEVATION 3/16"=1'-0" 10 8 7 11 REF. DW DN.-19 DN.-12 FIRE PLACE (E) POWDER A EXISTING MAIN HOUSE - FLOOR PLAN 3/16"=1'-0" 40'-0" EXISTING MAIN HOUSE 12 ' - 0 " EX I S T I N G M A I N H O U S E 29 ' - 9 " EX I S T I N G M A I N H O U S E 28'-0" EXISTING MAIN HOUSE 41 ' - 9 " EX I S T I N G M A I N H O U S E 12'-0" EXISTING MAIN HOUSE 4'-7" EXISTING WALL 7' - 7 " EX I S T I N G W A L L VANITY AND TOILET SHALL BE REMOVED. PRECAUTION TO TRY NOT TO DAMAGE. THEN RE-USE IT. LINE OF ROOF ABOVE. 11 ' - 3 " 12'-9" 10 ' - 2 " 5'-6" 3' - 0 " 3'-0" 6' - 6 " 7' - 9 " 8'-0" 9'-6" 12'-9" 10'-11" 11 ' - 0 " 11'-4"10'-7" 3' - 6 " 6' - 0 " 18 ' - 6 " 21'-11" (E ) 1 ' - 8 " (E) 5'-0"(E) 5'-1" (E ) 1 2 ' - 6 " (E)4'-0"(E)7'-8"(E ) 8 ' - 2 " (E ) 3 ' - 1 0 " 5'-6" 6' - 0 " 7' - 7 " 7' - 1 0 " (N) BATH 2 REF. DW DN.-19 DN.-12 FIRE PLACE B PROPOSED MAIN HOUSE - FLOOR PLAN (ADD BATH) 3/16"=1'-0" 40'-0" EXISTING MAIN HOUSE 12 ' - 0 " EX I S T I N G M A I N H O U S E 29 ' - 9 " EX I S T I N G M A I N H O U S E 28'-0" EXISTING MAIN HOUSE 41 ' - 9 " EX I S T I N G M A I N H O U S E 12'-0" EXISTING MAIN HOUSE SEE DETAIL 1: NEW BATHROOM 2 4'-7" EXISTING WALL 7' - 7 " E X I S T I N G W A L L 2' - 6 " 1' - 6 " 1' - 6 " 2' - 0 " 2'-2" 1 2 3 4 5 6 GFCI +48" EF VS 1 LAVATORY WITH BASE CABINET. FAUCET FLOW SHALL NOT EXCEED 1.2 GALLONS AT 60 PSI, MINIMUM 0.8 GALLONS PER MINUTE AT 20 PSI. 2 WATER CLOSET - 1.28 GALLONS PER FLUSH MAX. 3 SHOWER BASE: HOT-MAP PAN. PROVIDE TILE W/ CEMENT BACKING MIN. 72" HIGHT ABOVE SHOWER DRAIN, NET AREA 7.1 S.F. MIN., 30"DIA. CLEAR SPACE MIN. (CPC 411.7). 4 SHOWER HEAD FLOW IS 1.8 GPM MAX. SHOWER FITTING TO HAVE ACCESS PANEL OR ONE PIECE WELD TRAP PER LOCAL CODE 5 TEMPERED GLASS SHOWER ENCLOSURE, FRAMED GLASS WITH 22" OPENING MIN. UNOBSTRUCTED FOR EGRESS. 6 NEW 48"W x 24"H VINYL GLASS SLIDING WINDOW - TEMPERED GLASS WITH 0.29 U-FACTOR AND 0.21SHGC. EXISTING 2x WALL TO REMAIN AREA NOT IN SCOPE OF WORK EXISTING TO BE DEMOLISHED. 7 SHINGLES ROOF - REFER TO EXTERIOR MATERIAL SPECIFICATIONS - SHEET A1.04. 8 EXTERIOR CEMENT PLASTER WITH SAND FINISH TEXTURE AND LIGHT COLOR PAINTING. 9 1" x 4" RAISED ARCHITECTURAL TRIMS PAINT WITH ACCENT COLOR. 10 BRICK VENEER AND TRIM CAP BY THE SAME BRICK AND PAINT WITH ACCENT COLOR. 11 VINYL WINDOW WITH VINYL CASING AND TEMPERED GLASS. 6 12 TOP OF RIDGE +17'-0" TOP OF PLATE 9'-6" INTERIOR FINISH FLOOR 1'-6" GRADE LEVEL 0'-0" 5 PROPOSED MAIN HOUSE - NORTH WEST ELEVATION 3/16"=1'-0" 6 SEE DETAIL 1: NEW BATHROOM 2 10 8 7 11 FLUSH WALL MOUNTED DUPLEX RECEPTACLE, TAMPER RESISTANT GROUND FAULT CIRCUIT INTERRUPTERGFCI EF CEILING MOUNTED EXHAUST FAN/FLUORESCENT LIGHT COMBINATION. EXHAUST FAN TO EXTERIOR WITH RATE = 50 CFM. EXHAUST FAN MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE CAPABLE ADJUSTMENT BETWEEN RELATIVE HUMINITY RANGE OF 50% TO 80%. WALL MOUNTED LED LIGHT FIXTURE RECESSED LED DOWN LIGHT FIXTURE D / VS LIGHT SWITCH TO HAVE DIMMER CONTROL. D: INDICATE DIMMER VS: INDICATE OCCUPANCY SENSOR DELTA DATE DESCRIPTION MA I N H O U S E R E M O D E L - B A T H R O O M 40 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 NE W A D U 40 1 W J o n q u i l R d , U n i t 2 , S a n t a A n a , C A 9 2 7 0 6 3/19/2025 DATE SIGNED: ARCHITECTURE C DETAIL 1 - NEW BATHROOM 2 1/2"=1'-0" N N BATH 2 BATH 1 W/D WH BEDROOM 1 BEDROOM 2 BEDROOM 3 DINING LIVING REF. KITCHEN PANTRY -1.5"2% Min. 5 A2.03 D01.04 6'-7"3'-0"8'-8"2'-6"7'-1" 2' - 0 " 10 ' - 8 " 8' - 4 " 12 ' - 5 " 21'-3" 20 ' - 9 " 20'-3" 19'-1" 10 ' - 0 " 10 ' - 1 1 " 2' - 0 " 24 ' - 9 " 10'-0" 4' - 1 0 " 4' - 1 0 " 10'-0" 4'-9" 2' - 7 " 3'-6" 10'-0" 1'-3"1'-3" 5' - 6 " 5' - 6 " 2' - 9 " 6'-6"6'-6" 10'-5" 10 ' - 6 " 30'-6" 35 ' - 3 " 13 ' - 5 " 21 ' - 1 0 " 1'-2" EQ EQ 4' - 2 " EQ 4' - 2 " EQ 4'-4" 2' - 4 " D01.01 D01.02 D01.02 D0 1 . 0 2 a D01.02 D0 1 . 0 2 a D01.03 W 0 1 . 0 1 W 0 1 . 0 1 W 0 1 . 0 1 W 0 1 . 0 1 W 0 1 . 0 1 W01.02 W01.02 W01.04 W01.03 W01.03 1 2 345 1'-6"1'-6" 1'-6"1'-6" 1 2 4 5 3 6 7 8 910 A1.1 A1.2 A1.4A1.3 A2 24'-9"1.Hr EAVE 1'-0" OHG 32'-6" 1'-0" OHG 1.Hr WALL + EAVE 2'-6" OHG 1'-0" OHG A1 4'-0" 2'-6" 2' - 8 " 2' - 8 " 3' - 2 " U4 U5 U8 M2 11 1 A2.06 3' - 0 " M i n . 3'-0" Min. DOOR & WINDOW SCHEDULE NEW AND REPLACE WINDOW MUST BE COMPLY WITH ICC-228.4.9 (HABITABLE ROOMS) AND ICC-P104.4.1 (EGRESS WINDOW). REFER TO SHEET A2.06 1 LAVATORY WITH BASE CABINET. FAUCET FLOW SHALL NOT EXCEED 1.2 GALLONS AT 60 PSI, MINIMUM 0.8 GALLONS PER MINUTE AT 20 PSI. 2 THE TOILET IS AT LEAST 24 INCHES IN THE FRONT OF THE TOILET, 15 INCHES ON THE SIDES, AND AT LEAST 30 INCHES FROM ANYTHING ELSE IN THE BATHROOM. WATER CLOSET - 1.28 GALLONS PER FLUSH MAX. 3 SHOWER BASE: HOT-MAP PAN. PROVIDE TILE W/ CEMENT BACKING MIN. 72" HIGHT ABOVE SHOWER DRAIN, NET AREA 7.1 S.F. MIN., 30"DIA. CLEAR SPACE MIN. (CPC 411.7). 4 SHOWER HEAD FLOW IS 1.8 GPM MAX. SHOWER FITTING TO HAVE ACCESS PANEL OR ONE PIECE WELD TRAP PER LOCAL CODE 5 TEMPERED GLASS SHOWER ENCLOSURE, FRAMED GLASS WITH 22" OPENING MIN. UNOBSTRUCTED FOR EGRESS. 6 REFRIGERATOR - PROVIDE WATER LINE 7 KITCHEN SINK & FAUCET IS 1.8 GPM MAX. AT 60 PSI 8 KITCHEN CABINETRY 9 KITCHEN ISLAND CABINETRY 10 LINE OF ROOF ABOVE. LEGEND EXTERIOR WALL BELOW.R1 EDGE OF ROOF.R2 ROOF RIDGE.R3 NEW WALL - ALL EXTERIOR & PLUMBING WALLS: 2x6 @ 16" O.C. ALL INTERIOR WALLS: 2x4 @ 16" O.C. U.N.O. SHINGLES ROOF - REFER TO EXTERIOR MATERIAL SPECIFICATIONS. ROOF SLOPE PER PLAN KEY NOTES NEW 2x RATED WALL REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. REINFORCEMENT SHALL NOT BE LESS THAN 2" x 8" NOMINAL LUMBER (1-1/2” X 7-1/4” ACTUAL DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32” AND 39-1/4” ABOVE THE FINISHED FLOOR, FLUSH WITH THE WALL FRAMING. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6” ABOVE THE BATHTUB RIM. A1.1 A1.2 A1 INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION & MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CH. 4, DIVISION 4.4. REINFORCEMENT FOR GRAB BARS SHALL COMPLY AS FOLLOWING [R327.1.1]. A1.3 A1.4 A1.5 A2 PROVIDE DOORBELL BUTTON/CONTROL. INSTALLATION SHALL NOT EXCEED 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48” MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. 1HR FIRE RATED EXTERIOR WALL AND/OR EAVE PROJECTION. REFER TO DETAILS A ON SHEET A2.06 1.Hr WALL + EAVE U4 NEW DUAL ELECTRICAL PANEL 200 AMP. U7 NEW GAS METER LOCATION. U5 NEW 100AMP ELECTRICAL SUB-PANEL FOR ADU. U6 NEW 100AMP ELECTRICAL SUB-PANEL FOR MAIN HOUSE. U8 SOLAR PANEL SYSTEM. MULTI ZONE SPLIT SYSTEM AC. HEAT PUMP HEATING FACILITY ON PLAN TO MATCH WITH T-24 ENERGY CALCULATION. REFER TO SHEET A4.00 M2 AGING-IN-PLACE/FALL PREVENTION FEATURES. REFER DETAILS ON SHEET A2.06: PROVIDE CONCRETE LANDING AS SHOWN ON PLAN. LANDING SHALL BE MIN. 3' ON EGRESS DIRECTION. R4 11 GABLE VENT. REFER TO VENTILATION CALCULATION. R5 LOCATION FOR -kW PHOTOVOLTAIC SYSTEM. (N)6:12 (N ) 6 :1 2 (N ) 6 :1 2 (N ) 6 :1 2 (N ) 6 :1 2 (N ) 6 :1 2 (N)6:12 (N ) 6 :1 2 R1 R2 R3 32'-6" 1'-0" OH. 1'-0" OH. 26 ' - 9 " 1' - 0 " OH . 1' - 0 " OH . 8'-11" 1'-0" OH. 10 ' - 6 " 1' - 0 " OH . 24'-9" 2'-6" OH.1'-0" OH. 15 ' - 5 " 1' - 0 " OH . 1' - 0 " OH . 1'-2" 21 ' - 1 0 " 1' - 0 " OH . R4R4 R4 R5 1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2.EMERGENCY EXITS ARE REQUIRED IN ALL SLEEPING AREAS AND MAY BE PROVIDED BY A DOOR OR WINDOW OPENING DIRECTLY TO THE OUTSIDE. EMERGENCY EGRESS WINDOWS IN ALL SLEEPING ROOMS MUST COMPLY WITH THE FOLLOWING: A.A 20" MINIMUM OPENING WIDTH B.A 24" MINIMUM OPENING HEIGHT C.A SILL HEIGHT NO HIGHER THAN 44" ABOVE FINISHED FLOOR [CBC 1029.2.1] 3.LABELED SAFETY GLASS [CBC SECTION 2406.4] IS REQUIRED IN: A.TUB/SHOWER ENCLOSURE AND GLAZING WITHIN 60" FROM THE BOTTOM OF TUB/SHOWER B.WINDOWS ADJACENT TO A DOOR C.GLASS IN DOORS D.GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED. 4.OPEN GUARDRAILS SHALL HAVE INTERMEDIATE RAILS OR AN ORNAMENTAL PATTERN SUCH THAT A SPHERE 4" CANNOT THROUGH (CBC 509.1 & 1006.10). 5.ALL EXTERIOR DIMENSIONS ARE FROM FACE OF SHEATHING, BLOCK OR STRUCTURE (F.O.S.) TYP. UNLESS NOTED OTHERWISE. VERIFY DIMENSION CHANGES WITH ENGINEER PRIOR TO COMMENCEMENT OF WORK. 6.ALL INTERIOR DIMENSIONS ARE FROM FACE OF GYPSUM BOARD. 7.CONTRACTOR SHALL NOT SCALE PLANS. ALL DIMENSIONS SHALL BE VERIFIED IN FIELD. 8.ALL PLUMBING FIXTURES SHALL BE COMPLYING WITH THE MAXIMUM FLOW RATES AS NOTED IN THE RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS. 9. RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65% OF NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH SECTION 4.408.1 CALGREEN CODE. GENERAL NOTES REQUIRED: TOTAL AREA REQUIRED VENTILATION: 981 SF/150 = 6.54 SF 6.54 SF x 144 = 942 SQ.IN. VENTILATION CALCULATION FOR ADU PROVIDE: -3 GABLE VENT OPENINGS 18" X 24": 3 X (18 x 24) = 1,296 SQ.IN. DELTA DATE DESCRIPTION MA I N H O U S E R E M O D E L - B A T H R O O M 40 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 NE W A D U 40 1 W J o n q u i l R d , U n i t 2 , S a n t a A n a , C A 9 2 7 0 6 4/17/2025 DATE SIGNED: ARCHITECTURE N1PROPOSED ADU - FLOOR PLAN 1/4"=1'-0" N2PROPOSED ADU - ROOF PLAN 1/4"=1'-0" TOP OF RIDGE +17-8" TOP OF PLATE 10'-8" INTERIOR FINISH FLOOR 0'-8" GRADE LEVEL -0'-0" 12 6 1 2 TYP. 3 4 TYP. 5 TYP. 7 3 3' - 6 " SI L L H E I G H 2'-6" OH.1'-0" OH.1'-0" OH. TOP OF RIDGE +17-8" TOP OF PLATE 10'-8" INTERIOR FINISH FLOOR 0'-8" GRADE LEVEL -0'-0" 1 2 TYP. 3 4 56 1'-0" OH. 1'-0" OH. TOP OF RIDGE +17-8" TOP OF PLATE 10'-8" INTERIOR FINISH FLOOR 0'-8" GRADE LEVEL -0'-0" 12 612 6 4 3 2 TYP. 1 5 TYP. 7 3' - 0 " SI L L H E I G H 1'-0" OH.1'-0" OH. 1'-0" OH. TOP OF RIDGE +17-8" TOP OF PLATE 10'-8" INTERIOR FINISH FLOOR 0'-8" GRADE LEVEL -0'-0" 12 6 1 2 TYP. 33 7 5 TYP. 6 4 TYP. 3' - 0 " SI L L H E I G H 1'-0" OH. 1'-0" OH. 1'-0" OH. 1 1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2.EMERGENCY EXITS ARE REQUIRED IN ALL SLEEPING AREAS AND MAY BE PROVIDED BY A DOOR OR WINDOW OPENING DIRECTLY TO THE OUTSIDE. EMERGENCY EGRESS WINDOWS IN ALL SLEEPING ROOMS MUST COMPLY WITH THE FOLLOWING: A.A 20" MINIMUM OPENING WIDTH B.A 24" MINIMUM OPENING HEIGHT C.A SILL HEIGHT NO HIGHER THAN 44" ABOVE FINISHED FLOOR [CBC 1029.2.1] 3.LABELED SAFETY GLASS [CBC SECTION 2406.4] IS REQUIRED IN: A.TUB/SHOWER ENCLOSURE AND GLAZING WITHIN 60" FROM THE BOTTOM OF TUB/SHOWER B.WINDOWS ADJACENT TO A DOOR C.GLASS IN DOORS D.GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED. 4.OPEN GUARDRAILS SHALL HAVE INTERMEDIATE RAILS OR AN ORNAMENTAL PATTERN SUCH THAT A SPHERE 4" CANNOT THROUGH (CBC 509.1 & 1006.10). 5.ALL EXTERIOR DIMENSIONS ARE FROM FACE OF SHEATHING, BLOCK OR STRUCTURE (F.O.S.) TYP. UNLESS NOTED OTHERWISE. VERIFY DIMENSION CHANGES WITH ENGINEER PRIOR TO COMMENCEMENT OF WORK. 6.ALL INTERIOR DIMENSIONS ARE FROM FACE OF GYPSUM BOARD. 7.CONTRACTOR SHALL NOT SCALE PLANS. ALL DIMENSIONS SHALL BE VERIFIED IN FIELD. 8.ALL PLUMBING FIXTURES SHALL BE COMPLYING WITH THE MAXIMUM FLOW RATES AS NOTED IN THE RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS. 9. RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65% OF NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH SECTION 4.408.1 CALGREEN CODE. GENERAL NOTES KEY NOTES 2 3 1" x 4" RAISED ARCHITECTURAL TRIMS. PAINT WITH ACCENT COLOR TO MATCH EXISTING DWELLING. EXTERIOR CEMENT PLASTER: APPLY SKIP SAND FINISH TEXTURE AND LIGHT COLOR PAINTING. (TEXTURE & FINISH TO MATCH EXISTING DWELLING) INSTALLATION: 3-COAT (7/8" THICK) CEMENT PLASTER O/ SELF FURRING PAPER BACKED STUCCO NETTING O/ 2 LAYER GRADE 'D' PAPER (FELT). SHINGLES ROOF: OWENS CORNING - LAMINATE ARCHITECTURAL ROOFING SHINGLES. FIRE RATING (UL 790) CLASS A. ICC ESR-1389. GRAY COLOR & STYLE TO MATCH EXISTING DWELLING ROOF MATERIAL. INSTALLATION: OVER LAYERS UNDER-LAYMENT OVER PLYWOOD SHEATHING PER MANUFACTURE DIRECTION. 4 SIMILAR BRICK VENEER AND TRIM CAP BY THE SAME BRICK. PAINT WITH ACCENT COLOR TO MATCH EXISTING DWELLING. 5 WINDOW PER SCHEDULE - REFER TO SHEET A2.01. 6 DOOR PER SCHEDULE - REFER TO SHEET A2.01. 7 GABLE VENT - REFER TO SHEET A2.01. 9 CONCRETE FLOOR SLAB 10 CONCRETE FOOTING 11 12 ROOF/CEILING ASSEMBLY. REFER TO S-1 13 2X STUDS @ 16" O.C. PER PLAN 8 INSULATION SHALL CONFORM TO FLAME-SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF 2016 CBC. A.R-15 BATT INSULATION IN EXTERIOR WALLS. B.R-19 BATT INSULATION IN ATTIC ROOF. C.R-38 BATT INSULATION IN CEILING (BELOW ATTIC). EXTERIOR CEMENT PLASTER - SEE MATERIAL SPECIFICATIONS BEDROOM 1 12 6 LIVING TOP OF RIDGE +17-8" TOP OF PLATE 10'-8" INTERIOR FINISH FLOOR 0'-8" GRADE LEVEL -0'-0" CL O S E T KITCHEN 8 9 10 11 12 13 2 PROPOSED ADU - SOUTH EAST ELEVATION 1/4"=1'-0" 1 PROPOSED ADU - SOUTH WEST ELEVATION 1/4"=1'-0" 3 PROPOSED ADU - NORTH EAST ELEVATION 1/4"=1'-0"4 PROPOSED ADU - NORTH WEST ELEVATION 1/4"=1'-0" DELTA DATE DESCRIPTION MA I N H O U S E R E M O D E L - B A T H R O O M 40 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 NE W A D U 40 1 W J o n q u i l R d , U n i t 2 , S a n t a A n a , C A 9 2 7 0 6 3/19/2025 DATE SIGNED: ARCHITECTURE 5 PROPOSED ADU - SECTION 1/4"=1'-0" provide additional backing for fold away grab bar. verify requirement with selected manufacturer grab bar reinforcement for water closets back wall side wall 2' - 8 " M A X 2' - 8 " M A X 3' - 2 " M I N 3'-6" MIN1'-0" MAX 3' - 2 " M I N 2'-2" MIN 3'-4" MIN 1' - 4 " MI N 1'-4" 32 " full width at all shower stall walls side wallback wall grab bar reinforcement for shower 39 1 / 4 " full width at all shower stall walls Reinforcement shall not be less than 2x8 or other construction material providing equal height and load capacity AGING-IN-PLACE/FALL PREVENTION FEATURES AGING-IN-PLACE/FALL PREVENTION NOTES: A. Reinforcement for Grab Bars. [R327.1.1] At least one bathroom on the entry level shall be provided with reinforcement installed in accordance with this section. Where there is no bathroom on the entry level, at least one bathroom on the 2nd, or 3rd floor of the dwelling shall comply. 1. Reinforcement shall be solid lumber or other construction material approved by the enforcing agency. 2. Reinforcement shall not be less than 2 by 8 inch nominal lumber (1-1/2" x 7 1/4" actual dimension) or other construction material providing equal height and load capacity. Reinforcement shall be located between 32" and 39 1/4" above finish floor, flush with the wall framing. 3. Water closet reinforcement shall be installed on both side walls of the fixture, or one side wall and the back side wall. 4. Shower reinforcement shall be continuous where wall framing is provided. 5. Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the back wall. Additionally, back wall reinforcement for a lower grab bar shall be provided with the bottom edge located no more than 6" above the bathtub rim. 6. Where the water closet is not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for installation of floor-mounted, foldaway or similar alternate grab bar reinforcement approved by the enforcing agency. B. Documents for Grab Bar Reinforcement. [R327.1.1.] Information and/or drawings identifying the location of grab bar reinforcement shall be placed in the operation & maintenance manual in accordance with the California Green Building Standards Code, Chapter 4, Division 4.4 C. Electrical Receptacle Outlet, Switch & Control Height [R327.1.2] Electrical Receptacle outlets, switches and controls (including controls for heating, ventilation and air conditioning) intended to be used by occupants shall be located no more than 48" measured from the top of the outlet box and not less than 15" measured from the bottom of the outlet box above the finish floor. D. Interior Doors [R327.1.3] Effective July 1, 2024, at least one bathroom and one bedroom on the entry level shall provide a doorway with a net clear opening of not less than 32", measured with the door positioned at an angle of 90 degrees from the closed position; or in the case of 2- or 3- story single family dwelling, on the 2nd and 3rd floor of the dwelling if a bathroom and bedroom is not located on the entry level. E. Doorbell Buttons [R327.1.4] Doorbell buttons or controls, when installed, shall not exceed 48" above exterior floor or landing, measured from the top of the doorbell button assembly. Where doorbell buttons integrated with other features are required to be installed above 48" measured from the exterior floor or landing, a standard doorbell button or control shall also be provided at a height not exceeding 48" above exterior floor or landing, measured from the top of doorbell button or control. NOTE:SIZES ARE TAKEN FROM DATA SUPPLIED BY WINDOW MANUFACTURERS. HOWEVER THESE ARE GENERAL DIMENSIONS. IT IS THE OWNER"S RESPONSIBILITY TO VERIFY THAT THE ACTUAL WINDOWS INSTALLED MEET THE MINIMUM EGRESS REQUIREMENTS. STANDARD 6'-8" HEADER HEIGHT Casement Single/Double Hung Slider 44 " M A X . TO A C T U A L O P E N I N G 44 " M A X . TO A C T U A L O P E N I N G 34-1/8" CLEAR 20" CLEAR 41 " C L E A R 24 " C L E A R 44 " M A X . FLOOR LEVEL EMERGENCY ESCAPE/ EXIT WINDOW FOR BEDROOMS ICC-P104.4.1 REQUIREMENTS 1.20" MIN. CLEAR WIDTH 2.24" MIN. CLEAR HEIGHT 3.5.7 SF MIN. OPENABLE AREA (EXCEPT FOR GROUND FLOOR) 4.5.0 SF MIN. OPENABLE AREA FOR GROUND FLOOR MIN.WINDOW SIZE FOR 24" CLEAR HEIGHT (USING 5.7 S.F. REQ'T.) MIN. WINDOW SIZE FOR 20" CLEAR WIDTH (USING 5.7 S.F. REQ'T.) OPENABLE AREA OPENABLE AREA THE FOLLOWING WINDOW SIZES WILL BE THE MINIMUM ALLOWED FOR EGRESS UNLESS MANUFACTURERS DATA IS PROVIDED PROVIDING ACCEPTABLE OPENING SIZE FOR 5.7 SF (REQ'D. UNLESS FOR GROUND FLOOR) NEW FOR 2022 CBC - FOR 5.0 SF {GROUND FLOOR) Single Casement Single/Double Hung Slider Single Casement Single/Double Hung Slider Double Casement Double Casement NOTE:OTHER WINDOW TYPES SUCH AS AWNING. BAY W/ FIXED CENTER & SINGLE / FIXED COMBO ARE NOT ALLOWED AS AN EGRESS WINDOW UNLESS MFR'S DATA IS PROVIDED SHOWING ACCEPTABLE OPENING SIZE. 2'-4" x 4'-0" 2'-6" x 3'-6" 4'-8" x 4'-0" 5'-0" x 3'-6" 3'-0" x 5'-0" 3'-0" x 5'-6" 2'-6" x 6'-2" 2'-8" x 5'-8" 2'-4" x 6'-8" 4'-0" x 4'-0" 5'-0" x 3'-6" 6'-0" x 3'-0" 2'-4" x 3'-6" 2'-6" x 3'-0" 4'-8" x 3'-6" 5'-0" x 3'-0" 2'-9" x 5'-0" 3'-0" x 4'-8" 2'-6" x 5'-0" 2'-8" x 5'-2" 2'-4" x 5'-8" 4'-0" x 3'-6" 5'-0" x 3'-0" 6'-0" x 3'-0" FLOOR LEVEL MINIMUM WINDOW SIZE (NEW AND REPLACE WINDOW) EVERY HABITABLE ROOM MUST BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR OPENINGS WITH AN AREA NOT LESS THAN 8 PERCENT OF THE FLOOR AREA OF SUCH ROOMS. EVERY HABITABLE ROOM MUST BE PROVIDED WITH NATURAL VENTILATION BY MEANS OF EXTERIOR OPENINGS WITH AN AREA NOT LESS THAN 4 PERCENT OF THE FLOOR AREA OF SUCH ROOMS. ICC-228.4.9 REQUIREMENTS doorbell 48 " M A X 1' - 3 " MI N 4' - 0 " M A X electrical receptacle outlet, switch & control mounting heights push button doorbell heights finish floor 1 DETAIL A - 1HR FIRE RATED EXTERIOR WALL AND EAVE PROJECTION NTS DELTA DATE DESCRIPTION MA I N H O U S E R E M O D E L - B A T H R O O M 40 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 NE W A D U 40 1 W J o n q u i l R d , U n i t 2 , S a n t a A n a , C A 9 2 7 0 6 3/19/2025 DATE SIGNED: ARCHITECTURE 3 DETAIL C - AGING-IN-PLACE/FALL PREVENTION FEATURES NTS2DETAIL B - HABITABLE ROOM AND EGRESS WINDOW NTS CITY OF SANTA ANA 9111111 GENERAL REQUIREMENTS STRUCTURAL WOOD 49kJA01nUIL9G ncy STRUCTURAL STEEL FOUNDATION 1. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL GRADES, SHEAR WALL SCHEDULE: 1. THE FOUNDATION DESIGN IS BASED UPON CHAPTER 4 C.R.C. THE CONTRACTOR DIMENSIONS, ELEVATIONS AND CONDITIONS AT THE JOB SITE PRIOR TO BIDDING 1. REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH ACI 315 AND ACI 318, SHALL BE RESPONSIBLE FOR ALL REQUIREMENTS THEREIN AND MAINTAIN A COPY AND COMMENCING CONSTRUCTION. CROSS CHECK ALL DETAILS AND DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS WITH RELATED REQUIREMENTS ON THE ARCHITECTURAL, ELECTRICAL, MECHANICAL, AND CIVIL DRAWINGS AND NOTIFY THE ENGINEER AND THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING WORK. 2. EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE NOTED OR SHOWN IN THE PLANS OR SPECIFICATIONS, ALL PHASES OF WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE BUILDING CODE, LATEST ADDITION, AS WELL AS ALL APPLICABLE STATE AND LOCAL ORDINANCES AS ADOPTED BY THE CONTROLLING JURISDICTION. 3. THE CONTRACT DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE STRUCTURE SHOWN ON THESE DRAWINGS IS STRUCTURALLY SOUND ONLY IN THE COMPLETED FORM. GENERAL CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKMEN, AND OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES INCLUDE, BUT ARE NOT LIMITED TO; BRACING, SHORING FOR CONSTRUCTION EQUIPMENT,AND SHORING FOR THE STRUCTURE. 4. TIN NO CASE SHALL DIMENSIONS BE SCALED FROM DRAWINGS AND/OR DETAILS. ANY DISCREPANCIES FOUND WITHIN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER FOR TYPE SHEAR PANEL SILL PLATE FRAMING CLIP NAILING A35's,LS50's 16D SINKER OR LTP4's. 260 PLF 3/8" APA STRUCT. RATED PLYWOOD(or OSB) 6" O.C., OR 16" O.C. WITH 8d COMMON NAILS AT 6" O.C. EDGES A35 @ 24" O.C. AND 12" O.C. FIELD �2 380 PLF 3/8" APA STRUCT. RATED PLYWOOD(or OSB) 4" O.C., OR 12" O.C. WITH 8d COMMON NAILS AT 4" O.C. EDGES A35 @ 16" O.C. AND 12" O.C. FIELD 3/8" APA STRUCT. RATED PLYWOOD(or OSB) 3" O.C., OR 8" O.C. �3 490 PLF WITH 8d COMMON NAILS AT 3" O.C. EDGES A35 @ 12" O.C. AND 12" O.C. FIELD 3/8" APA STRUCT. RATED PLYWOOD(or OSB) 2" O.C., OR 6" O.C. 4 640 PLF WITH 8d COMMON NAILS AT 2" O.C. EDGES A35 @ 10" O.C. AND 12" O.C. FIELD 15/32" APA STRUCT I. RATED PLYWOOD (2)3" O.C., OR 5" O.C. �5 800 PLF WITH 10d COMMON NAILS AT 2" O.C. EDGES A35 @ 6" O.C. AND 12" O.C. FIELD AND CRSI'S MANUAL OF STANDARD PRACTICE. ON THE JOB SITE AT ALL TIMES. 2. REINFORCING STEEL SHALL CONFORM TO ASTM A615OR ASTM 716(WELDABLE 2. THE ENGINEER OF RECORD MUST BE INFORMED OF ANY CHANGES IN DESIGN STEEL) AND SHALL BE GRADE 60 DEFORMED BARS TYP. U.N.O. REINFORCING IN CRITERIA MADE BY ANY SOILS GEOLOGIST IN THE COURSE OF CONSTRUCTION. SLAB ON GRADE MAYBE GRADE 40 STEEL FOR BARS #4 AND SMALLER U.N.O ON THE 3. ALL FOOTINGS AND SLABS SHALL BE FOUNDED ON FIRM UNDISTURBED NATURAL PLANS. SOILS OR APPROVED COMPACTED FILL. CONTRACTOR TO PROVIDE BUILDING 3. WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. LAPS IN WWF SHALL INSPECTOR WITH COMPACTION REPORTS AND/OR WRITTEN APPROVAL OF BE SUCH THAT THE OVERLAP MEASURED BETWEEN OUTERMOST CROSS WIRE OF COMPACTED FILL FROM A SOIL GEOLOGIST FOR ANY REQUIRED FILL. EACH FABRICH SEET IS NOT LESS THAN THE SPACING OF CROSS WIRES PLUS 2 4. ALL COMPACTED FILL SHALL BE PLACED IN AN APPROVED MANNER WITH A MINIMUM INCHES. DENSITY OF 90% OF THE MAXIMUM OBTAINABLE IN ACCORDANCE WITH ASTM D 1557. 4. ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING BARS/STEEL ARE TO 5. ALL FOUNDATION EXCAVATIONS, FILLING, BACK FILLING, AND BUILDING PADS SHALL THE CENTER OF STEEL U.N.O. ON THE PLANS OR DETAILS: BE INSPECTED AND APPROVED BY THE CITY BUILDING INSPECTOR BOTH PRIOR TO, CONDITION COVER AND AFTER PLACEMENT OF REINFORCEMENT. THE CONTRACTOR SHALL BE A. CAST AGAINST AND PERMANENTLY EXPOSED RESPONSIBLE FOR ALL SHORING NECESSARY TO SUPPORT CUT AND/OR FILL TO EARTH 3" SECTIONS DURING EXCAVATION AND FOR FORMING AND PLACEMENT OF CONCRETE. B. EXPOSED TO EARTH OR WEATHER 6. THE CONTRACTOR SHALL INFORM THE ARCHITECT AND ENGINEER OF THE LOCATION (INCLUDING SLABS ON GRADE) OF EXISTING UTILITIES AND COMMENCE WORK ONLY AFTER WRITTEN APPROVAL FROM THE ARCHITECT. # AND LARGER 2" 7. ALL RETAINING WALLS HAVE BEEN DESIGNED AS A FREE DRAINING CONDITION. #5 AND SMALLER 1 1/2" DESIGN FOR THE DRAINAGE SYSTEM SHALL BE BY OTHERS AND SHALL MEET THE C. NOT EXPOSED TO WEATHER OR REQUIREMENTS OF THE SOILS REPORT.BACK FILL AGAINST WALLS SHALL BE PLACED IN CONTACT WITH SOIL: EVENLY AGAINST BOTH SIDES OF WALLS UNTIL THE LOWER GRADE IS REACHED. 1. STRUCTURAL SLABS, WALLS w/ 8. FOOTING WITH MINIMUM REINFORCEMENT OF: 2#4 @ TOP & 2#4 @ BOTTOM. OR U.N.O CLARIFICATION PRIOR TO PROCEEDING. ANY WORK INSTALLED PRIOR TO 411 BARS AND SMALLER 3/4 9. EXISTING FOOTING : USE EPDXY FOR A.B. WITH SAME LENGTH AS REGULAR BOLTS AND/OR IN CONFLICT WITH SUCH CLARIFICATION SHALL BE CORRECTED BY THE #14 BARS AND LARGER 1 1/2" WITH SPECIAL INSPECTION. CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER. SHEAR WALL NOTES: 2. BEAMS, COLUMNS 1 1/2" 1. FRAMING ATADJOINING PANEL EDGES SHALL BE 3 INCHES NOMINAL OR WIDER, AND NAILS 5. LAP SPLICES OF BARS SHALL CONFORM TO THE TYPICAL THE LAP SCHEDULE ON THE ANCHOR BOLTS: 5. THE PRECISE DIMENSIONS AND LOCATIONS OF ALL DOOR AND WINDOW SHALL BE STAGGERED WHERE NAILS ARE SPACED 2 INCHES ON CENTER. PLANS, U.N.O. NO TACK WELDING OF BARS ALLOWED 1. MINIMUM 5/8"0 STEEL BOLTS EMBEDDED 7" @ 48" O.C. INTO THE FOUNDATION WITH OPENINGS, INTERIOR AND EXTERIOR WALLS SHALL BE DETERMINED FROM THE 2, WHERE SHEAR DESIGN VALUES EXCEED 350 PLF., ALL FRAMING MEMBERS RECEIVING 6. MECHANICAL SPLICE COUPLERS MAY BE USED AND SHALL HAVE CURRENT ICC MINIMUM 3" S.Q x 0.25" PLATE WASHER FOR THE ANCHOR BOLTS. MINIMUM EDGE DISTANCE ARCHITECTURAL DRAWINGS. OTHER FLOOR, WALL AND ROOF OPENINGS AS EDGE NAILING FROM ABUTTING PANELS SHALL NOT BE LESS THAN SINGLE 3-INCH APPROVAL AND BE CAPABLE OF DEVELOPING 125% OF THE BAR'S YIELD STRENGTH. 1-7/8" AND WITHIN 12" OF EACH END OF EACH PLATE. REQUIRED FOR MECHANICAL, ELECTRICAL AND/OR SIMILAR REQUIREMENTS NOMINAL MEMBER, OR TWO 2-INCH NOMINAL MEMBERS FASTENED TOGETHER IN 7. ALL REINFORCING BARS SHALL BE BENT COLD. DO NOT FIELD BEND OR UNBEND ANY 2. ALL SHEAR HARDWARE AND ANCHOR BOLTS W/ NON-STANDARD SPACING ARE TO BE FIXED SHALL BE VERIFIED FROM SHOP DRAWINGS, EQUIPMENT DATA, ETC. AS ACCORDANCE WITH SECTION 2306.1 TO TRANSFER THE DESIGN SHEAR VALUE BETWEEN BARS IN A MANNER THAT MAY DAMAGE REINFORCING. IN PLACE FOR THE FOUNDATION INSPECTION. REQUIRED. FRAMING MEMBERS. WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE 8. REINFORCING SPACING SHOWN ON THE PLANS ARE THE MAXIMUM SPACING "ON 3. FASTENERS FOR PRESERVATIVE -TREATED SHALL BE NOT DIPPED ZINC -COATED 6. FLOOR AND WALL OPENINGS, SLEEVES, VARIATIONS IN STRUCTURAL SLAB STAGGERED IN ALL CASES. SEE SECTION 2305.3.11 FOR SILL PLATE SIZE AND ANCHORAGE CENTER SPACING". DO NOT EXCEED THIS. ANY DISCREPANCIES DURING GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. ELEVATIONS, DEPRESSED AREAS, AND ALL OTHER ARCHITECTURAL, REQUIREMENTS. NAILS SHALL BE PLACED NOT LESS THAN 1/2" EDGE DISTANCE FROM THE CONSTRUCTION SHALL BE FORWARDED TO THE ENGINEER FOR REVIEW AND 4. A PROPERLY SIZED NUT AND WASHER SHALL BE TIGHTENED ON EACH ANCHOR BOLT TO MECHANICAL, ELECTRICAL, AND/OR CIVIL REQUIREMENTS MUST BE PANEL EDGES AND 3/8" FROM THE EDGE OF THE CONNECTING APPROVAL. THE PLATE. COORDINATED BEFORE THE CONTRACTOR PROCEEDS WITH CONSTRUCTION. MEMBERS. 9. TYPICAL REINFORCING FOR CONCRETE SLAB ON METAL DECK SHALL BE 5. HOLDOWN CONNECTORS BOLTS HOLES SHALL NOT BE MORE THAN 1/16" OVERSIZED AT 3. ANCHOR BOLTS FOR SHEAR WALLS SHALL INCLUDE STEEL PLATE WASHERS, A MINIMUM 6x6-W1.4xW1.4 WELDED WIRE FABRIC, U.N.O. PLACE WWF MID -DEPTH OF THE SLAB THE CONNECTOR OF THE HOLD DOWN TO THE POST. 7. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION AND OF 0.229INCHES BY INCHES BY INCHES IN SIZE, BETWEEN THE SILL PLATEAND NUT. OVER THE TOP OF THE FLUTE OF THE METAL DECK. 6. HOLD DOWN CONNECTORS SHALL BE RE -TIGHTENED JUST PRIOR TO COVERING THE WALL COORDINATION WITH ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, FRAMING. PLUMBING, FIRE SPRINKLER DRAWINGS,AND ALL OTHER RELATED DRAWINGS. 10. ALL DOWELS TO BE SET IN CONCRETE SHALL BE TIED IN PLACE PRIOR TO THE CONTRACTOR IS RESPONSIBLE FOR THE AND ALL OTHER RELATED PLACEMENT OF CONCRETE. NO WET SETTING, STABBING, RODDING OR OTHER 7. ALL FOUNDATIONS SHALL BEAR UPON LIKE MATERIAL. DRAWINGS. MOVEMENT OF EMBEDDED ITEMS SHALL BE PERFORMED DURING THE PLACEMENT 8. FINAL SOILS / AS -GRADED REPORT WILL BE REQUIRED AT FOUNDATION / SLAB INSPECTION. WOOD OF CONCRETE.11. 8. IN ALL CASES WHERE A CONFLICT MAY OCCUR SUCH AS BETWEEN ITEMS DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, INCLUDED IN THE SPECIFICATIONS AND NOTES ON THE DRAWINGS, OR BETWEEN SIZE AND SPACING AS THE MAIN REINFORCING, UNO. GENERAL NOTES AND SPECIFIC DETAILS, THE ENGINEER SHALL BE NOTIFIED AND 1. ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR LARCH CONFORMING TO WEST 12. CHAIRS OR SPACERS FOR REINFORCING SHALL BE NON-FERROUS OR PLASTIC SHEET INDEX HE WILL INTERPRET THE INTENT OF THE CONTRACT DOCUMENTS. COAST LUMBER INSPECTION BUREAU GRADING RULES #17. MOISTURE CONTENT NOT TO EXCEED 19°/ AT TIME OF CONSTRUCTION COATED WHEN RESTING ON EXPOSED SURFACES. 9. ALL MATERIALS SHALL BE FURNISHED AS SHOWN HEREIN UNLESS ALTERNATES CONCRETE MASONRY ARE APPROVED IN WRITING BY THE ARCHITECT, OWNER AND STRUCTURAL 2. WOOD -BASED STRUCTURAL USE PANELS SHALL MEET THE REQUIREMENTS OF DOC ENGINEER OF RECORD. PS 2-10. STRUCTURAL SHEATHING MAY BE EITHER OSB OR PLYWOOD. GENERAL 10. ANY REFERENCE TO THE WORDS APPROVED OR APPROVAL IN THESE 1. ALL CONCRETE MASONRY MATERIALS AND CONSTRUCTION SHALL BE IN DOCUMENTS SHALL BE DEFINED TO MEAN GENERAL ACCEPTANCE OR REVIEW 3. STRUCTURAL COMPOSITE LUMBER (SCL) SHALL CONFORM TO THE MANUFACTURER'S ACCORDANCE WITH BUILDING CODE, CHAPTER 21. AND SHALL NOT RELIEVE THE CONTRACTOR AND/OR HIS SUBCONTRACTORS OF ICC REPORT IN COMPLIANCE WITH THE GOVERNING BUILDING CODE FOR THE MATERIALS ANY LIABILITY IN FURNISHING THE REQUIRED MATERIALS OR LABOR PROJECT LISTED. 2. ALL MATERIALS MAKING UP FINISHED CONCRETE MASONRY CONSTRUCTION SHALL SPECIFICATION. CONFORM TO STANDARDS REQUIRED BY BUILDING CODE SEC. 2103. 4. ENGINEERED GLU-LAM BEAMS SHALL BE INSPECTED AND AN A.I.T.C. CERTIFICATE OF 3. MORTAR SHALL BE TYPE M OR S AS APPLICABLE AND CONFORMING WITH ASTM C270 11. WHERE A DETAIL, SECTION OR NOTE IS SHOWN FOR ONE CONDITION, IT SHALL COMPLIANCE SHALL BE PROVIDED TO THE INSPECTOR PRIOR TO INSTALLATION. ALL AND SHALL BE PROPORTIONED PER ARTICLE 2.1 & 2.6A OF SPECIFICATION FOR APPLY FOR ALL LIKE OR SIMILAR CONDITIONS UNLESS NOTED OTHERWISE. GLU-LAM BEAMS SHALL BE FABRICATED WITH WATERPROOF GLUE WITH STANDARD MASONRY STRUCTURES (TMS 602-16). DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY CAMBER 11 N O 4. GROUT SHALL COMPLY WITH ARTICLE 2.2 OF TMS 602-16 AND SHALL ATTAIN A No. SHEET NO. SHEET NAME 1 S0.0 - GENERAL STRUCTURAL NOTES. 2 S0.1 - TYPICAL DETAILS. 3 S1.0 - FOUNDATION PLAN & FRAMING PLAN. 4 SD1 - STRUCTURAL DETAILS. 5 SD2 - STRUCTURAL DETAILS. INDICATED OTHERWISE. WHERE NO SPECIFIC DETAIL IS SHOWN, THE FRAMING MINIMUM COMPRESSION STRENGTH AT 28 DAYS OF 1500 PSI OR THE REQUIRED OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO LIKE CASES OF 5. GLU-LAM BEAMS MAY NOT BE SUBSTITUTED FOR STRUCTURAL COMPOSITE LUMBER COMPRESSION, FM, WHICHEVER IS GREATER. THE COMPRESSIVE STRENGTH OF CONSTRUCTION. (SCL) BEAMS UNLESS WRITTEN AUTHORIZATION IS PROVIDED BY THE ENGINEER OF GROUT SHALL BE DETERMINED IN ACCORDANCE WITH ASTM C-1019. 12. CONNECTIONS OF ALL ITEMS SUPPORTED BY THE STRUCTURE ARE THE RECORD. 5. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 FOR LOAD BEARING RESPONSIBILITY OF THE DISCIPLINES WHO MAKE THESE ATTACHMENTS. REVIEW CONCRETE MASONRY UNITS. CONCRETE BRICK SHALL CONFORM TO ASTM C55, AND COORDINATE ALL THE REQUIREMENTS IN THE ARCHITECTS PROJECT 6. ALL WOOD FRAMING MEMBERS DIRECTLY AGAINST CONCRETE OR MASONRY SPECIFICATIONS FOR CONCRETE BUILDING BRICK. SPECIFICATION AS APPLICABLE. INSTALLED IN A DRY OR ENCLOSED ENVIRONMENT SHALL BE PRESSURE TREATED 6. GRADE N CONCRETE BRICKS ARE FOR USE AS ARCHITECTURAL VENEER AND 13. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING DOUG-FIR TREATED WITH SODIUM BORATE (SBX/DOT). CORROSION RESISTANT 7. FACING, LIMITED TO IN EXTERIOR WALLS. GRADE S CONCRETE BRICKS ARE FOR GENERAL USE WHERE MODERATE STRENGTH UTILITIES, WHETHER INDICATED ON THE CONTRACT DRAWING OR NOT, AND TO CONNECTORS ARE NOT REQUIRED WITH SODIUM BORATE TREATED LUMBER. IF AND RESISTANCE TO FROST ACTION AND MOISTURE PENETRATION IS REQUIRED. PROTECT THEM FROM DAMAGE. REPAIR AND REPLACEMENT OF SAID WORK OTHER TREATMENTS ARE USED, GALVANIZED FASTENERS PER "FASTENER STRENGTH SHALL BE AT THE EXPENSE OF THE CONTRACTOR. REQUIREMENTS" NOTE 3 ARE REQUIRED. 8. THE SPECIFIED COMPRESSIVE STRENGTH OF MASONRY, F'M, SHALL BE 2000 PSI, 14. VIBRATIONAL EFFECTS OF MECHANICAL AND/OR ANY OTHER EQUIPMENT HAVE 7. LUMBER GRADE STAMPS ARE TO REMAIN IN PLACE AFTER INSTALLATION WHERE UNLESS NOTED OTHERWISE. IF HIGHER FM IS NOTED, IT SHALL BE VERIFIED BY NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER. POSSIBLE. PRISM TESTS AS REQUIRED IN ARTICLE 1.4 SPECIFICATION OF MASONRY 15. UNLESS NOTED OTHERWISE, ELEVATIONS SHOWN ON THE STRUCTURAL STRUCTURES (TMS 602-16). DRAWINGS ARE TO THE TOP OF BEAMS AND FOUNDATIONS. BEAMS DENOTED AS 8. LUMBER GRADES ARE TO BE AS FOLLOWS: 9. REINFORCING STEEL SHALL CONFORM TO ASTM A615. GRADE 40 FOR SIZES #3 AND "DROP" HAVE THE TOP OF BEAM AT THE HEIGHT OF THE TOP PLATE. BEAMS STUDS UP TO 10'-0................................................................................................ STUD GRADE GRADE 60 FOR SIZES #4 AND LARGER. DENOTED AS "FLUSH" HAVE THE BOTTOM OF BEAM AT THE HEIGHT OF THE TOP STUDS OVER 10'-0...................................................................................... ... ........DF #2 SPECIAL INSPECTION PLATE, U.N.O. BLOCKING............................................................................................STANDARD OR BETTER 10. SPECIAL INSPECTION FOR CONCRETE MASONRY CONSTRUCTION SHALL BE CARRIED PLATES & SILLOR BETTER OUT IN ACCORDANCE WITH BUILDING CODE SECTION 1704 AND REQUIREMENTS IN DESIGN CRITERIA .....................................................................................STANDARD TOP PLATES........................................................................................................................DF #2 SPECIAL INSPECTION TABLES ON SHEET SN-1. MASONRY COMPRESSIVE STRENGTH, 1. SOILS 4X4 BEAMS/POSTS.............................................................................STANDARD OR BETTER FM SHALL BE VERIFIED BY UNIT STRENGTH METHOD OR PRISM TEST METHOD PRIOR SOILS ALLOWABLE DESIGN VALUES IS 1500 PSF, 4X6 THROUGH 4X12BEAMS/POSTS.................................................................................DF #2 TO AND DURING CONSTRUCTION AS DESCRIBED IN ARTICLE 1.4 SPECIFICATION FOR 4X14BEAMS/POSTS.............................................................................................................DF#1 MASONRY STRUCTURES (TMS 602-16). 2. BUILDING CODE - 2022 CALIFORNIA BUILDING CODE 6X & LARGER BEAMS/POSTS............................................................................................DF #1 REINFORCED CONCRETE 3. DESIGN LOADS: 2X RAFTER/JOIST...............................................................................................................DF #2 1. CONCRETE SHALL BE SUPPLIED AND PLACED IN ACCORDANCE WITH THE LATEST ROOF LOAD 9. UTILITY GRADE LUMBER IS UNACCEPTABLE FOR ANY PURPOSE. EDITION OF ACI 318 AND ACI 301 EXCEPT AS MODIFIED BY THE CONSTRUCTION DEAD LOAD = 20 PSF DOCUMENTS. LIVE LOAD = 20 PSF 10. THE FOLLOWING BEAMS/HEADERS/RIMS CAN BE FROM ANY MANUFACTURER WITH 2. PORLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE II, U.N.O. TOTAL = 40 PSF CURRENT 3. AGGREGATE FOR STONE CONCRETE SHALL CONFORM TO ASTM C-33. FOR 4. LATERAL LOADS: APPROVED ICC ES - EVALUATION REPORT WITH THE FOLLOWING MECHANICAL LOWSHRINKAGE AGGREGATE, USE LIMESTONE OR GRANITE. AGGREGATE RISK CATEGORY: II PROPERTIES: FORLIGHTWEIGHTCONCRETE SHALL CONFORM TO ASTM C-330 SEISMIC DESIGN CATEGORY: D WIND SPEED: 110 MPH 4. DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER USED IN SEISMIC IMPORTANCE FACTOR (1) = 1.0 WIND EXPOSURE: C FOR "LVL" & "PSL" BEAMS: MIXING CONCRETE SHALL CONFORM WITH ASTM C1602. SITE CLASS = D-Default Fb = 2900 psi (MIN), Fv = 290 psi (MIN), E = 2.0 x 106 psi (MIN). 5. CONCRETE MIX DESIGNS CONTAINING FLY ASH MAY BE USED WHERE CONCRETE IS NOT VISUALLY EXPOSED. FLY ASH SHALL CONFORM WITH ASTM C618 AND MAY FOR "LSL" BEAMS/HEADERS: REPLACE UP TO 20% PORTLAND CEMENT BY VOLUME. S5: 1.335 Csy: 0.115 CSX: 0.115 Fb = 2325 psi (MIN), Fv = 400 psi (MIN), E = 1.55 x 106 psi (MIN). 6. CONCRETE STRENGTH TEST REPORTS SHALL BE IN COMPLIANCE WITH ACI 318 AND Sl: 0.475 Ry: 6.5 Rx: 6.5 SHALL BE SUBMITTED TO E.O.R. FOR REVIEW. BASIC SEISMIC FORCE RESISTING SYSTEM: PLYWOOD SHEAR WALL FOR MANUFACTURED RIM BOARD WITH MIN 1 1/4" THICK, CONTINUOUSLY SUPPORTED 7. ALL REINFORCING BARS, ANCHOR BOLTS AND ALL OTHER CONCRETE INSERTS ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE BY WALL, AND MATCHES JOIST DEPTH: SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. 5. LUMBER GRADES (U.N.O.) Fc I (PERPENDICULAR)........ = 680 psi (MIN) 8. THE CONCRETE COMPRESSIVE STRENGTH (28 DAYS), fc: 6X & 8X POSTS/BEAMS/HEADERS: #1 DFL Fc // (PARALLEL) ..................... = 1400 psi (MIN) a. ALL LOCATIONS, U.N.O: MIN 2500 PSI, (W/C = 0.45) SPECIAL INSPECTION IS 4X POSTS/BEAMS/HEADERS: #2 DFL Ft = 1075 psi (MIN), E = 1.3 x 106 psi (MIN) REQUIRED WHEN fc > 2500 PSI. 2X JOISTS/RAFTERS: #2 DFL b. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 _> 0.1% BY WEIGHT: STUDS: D.F.L. STUD GRADE (UP TO 9'-0"), D.F.L. #2 (HIGHER THAN 9'-0") GLU-LAM BEAM SHALL BE 24F-V4, DF/DF 4000 PSI, SPECIAL INSPECTION IS NOT REQUIRED. TOP PLATES & MUD SILLS: D.F.L. CONSTRUCTION GRADE,#2, OR BETTER. Fb = 2400 psi @ BOTTOM, Fb = 1850 psi @ TOP c. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 >_ 0.2% BY WEIGHT: Fv = 265 psi (MIN), E = 1.8 x 106 psi (MIN). 4500 PSI, SPECIAL INSPECTION IS NOT REQUIRED. 6. TYPICAL FLOOR SHEATHING 9. TIME BETWEEN CONCRETE BATCHING AND PLACEMENT SHALL BE IN ACCORDANCE 23/32" APA RATED STURD-I-FLOOR T&G EXP I (OR OSB) WITH MIN. 11. ROOF SHEATHING SHALL BE 15/32" APA RATED SHEATHING EXP 1 WITH A SPAN WITH ASTM C94. SPAN RATING OF 24" O.C. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS RATING OF 24/0 WITH 8D NAILS AT 6" O/C AT EDGES AND BOUNDARIES AND 12" O/C 10. CONCRETE PLACEMENT/CURING/REDUCTION IN STRENGTH SHALL CONFORM TO ACI OF USE FIELD NAILING. 305R AND 3065R REQUIREMENTS FOR HOT AND COLD WEATHER CONCRETING. B.N.:10D COMMON NAILS AT 6" O.C. 11. CONCRETE SHALL BE CURED PER ACI 308R, UNLESS ALTERNATE METHODS OF E.N.:10D COMMON NAILS AT 6" O.C. 12. FLOOR SHEATHING SHALL BE 23/32" APA RATED SHEATHING EXP 1 WITH A MINIMUM CURING HAVE BEEN APPROVED BY THE ARCHITECT OR ENGINEER. FOR SLAB F.N.-.10D COMMON NAILS AT 12" O.C. SPAN RATING OF 48/24 WITH 10D NAILS AT 6" O/C AT EDGES AND BOUNDARIES AND 10" CURING, CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING COMPATIBILITY OF O/C FIELD NAILING. CURING COMPOUNDS WITH PROPOSED FINISHES PRIOR TO COMMENCING ANY USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING USING WORK. ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN 12. MAX. SLUMP SHALL BE 5 INCHES EXCEPT WHERE ADM IXTURES/PLACITIZERS HAVE ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. BEEN ADDED IN THE MIX DESIGN TO IMPROVE FLOW ABILITY/WORKABILITY. THE SLUMP LIMIT SHALL BE BASED ON ADMIXTURE MANUFACTURER'S AS AN ALTERNATE TO 10D COMMON NAILS, THE FOLLOWING FASTNERS CAN BE RECOMMENDATIONS. USED: GRABBER PLYWOOD SCREWS (ICC-ER-5280), OR SIMPSON STRONG -TIE QUICK DRIVE SCREWS (ICC-ER-1472), MIN 2" LONG @ 6" O.C. B.S., @ 6" O.C. E.S. AND 12" O.C. F.S. 7. TYPICAL ROOF SHEATHING DOC PS1 OR DOC PS2. 15/32" APA RATED SHEATHING EXP 1 (OR OSB) WITH A MIN. PANEL INDEX OF 32/16. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. B.N.:8D COMMON NAIL AT 6" O.C. E.N.:8D COMMON NAIL AT 6" O.C. F.N.:8D COMMON NAIL AT 12" O.C. NOTE: ALL STRUCTURAL RATED PANELS MUST BE STAMPED BY ONE OF THE FOLLOWING APPROVED AGENCIES, APA, PFS/TECO OR PITTSBURG. NAILING SCHEDULE- (TABLE R602.3(1) W/ FOOT NOTES 2022 CRC) DESCRIPTION OF BUILDING NUMBER AND TYPE OF SPACING AND ITEM ELEMENTS FASTENERa, b, c LOCATION Blocking between ceiling joists or 4-8d box (2 1/2" x 0.113") or 3-8d 1 rafters to top plate common (2 1/2" x 0.131"); or 3-10d box Toe nail (3" x 0.128"); or 3-3" x 0.131" nails 4-8d box (2 1/2" x 0.113"); or 3-8d 2 Ceiling joists to top plate common 2 1/2" x 0.131 "); or 3-10d box Per joist, toe nail (3" x 0.128"); or 3-3" x 0.131" nails Ceiling joist not attached to parallel rafter, laps over partitions [see 4-10d box (3" x 0.128"); or 3-16d 3 Sections R802.3.1, R802.3.2 and common (3 1/2" x fl; Face nail Table R802.5.1(9)] ails or 4-3" x 0.131"nails Ceiling joist attached to parallel rafter 4 (heel joint) [see Sections R802.3.1 Table R802.5.1(9) Face nail nd R802.3.2 and Table R802.5.1(9) Collar tie to rafter, face nail or 11/4" x 4-10d box (3" x 0.128"); or 3-10d 5 20 ga. ridge strap to rafter common (3" x 0.148"); Face nail each rafter or 4-3" x 0.131" nails 3-16d box nails (3 1/2" x 0.135"); 2 toe nails on one 6 Rafter or roof truss to plate or 3-10d common nails (3" x 0.148"); side and 1 toe nail on or 4-10d box (3" x 0.128"); opposite side of each or 4-3" x 0.131" nails rafter or truss 4-16d (3 1/2" x 0.135"); or 3-10d common (3 1/2" x 0.148"); or4-10d box Toe nail Roof rafters to ridge, valley (3" x 0.128"); or 4-3" x 0.131" nails 7 or hip rafters or roof rafter to minimum 2" ridge beam 3-16d box 3 1/2" x 0.135"); or 2-16d common (3 1/2" x 0.162"); or 3-10d box End nail (3" x 0.128"); or 3-3" x 0.131" nails WALL Stud to stud (not at braced wall 16d common (3 1/2" x 0.162") 24" o.c. face nail 8 panels) 10d box x .1 16" o.c. face nail or „ x Stud to stud and abutting studs at 4-10d box (3" x 0.128"); or 3-16d 9 intersecting wall corners (at braced common (3 1/2" x 0.162"); 12" o.c. face nail wall panels) or 4-3" x 0.131" nails 16d common (3 1/2" x 0.162") 16" o.c. fP al Built-up header (2" to 2" header with 16d common (3 1/2" x 0.162") 16" .c. e h face nail 10 1/2" spacer) 16d box (3 1/2" x 0.135") .c. each edge face nail 5-8d box x 11 Continuous header to stud or 4-8d common (2 1/2" x 0.131 "); Toe nail - "x or 4 10d box 3 0.128 16d common (3 1/2" x 0.162") 16" o.(AfAc,&1nai1i6- 12 Top plate to top plate 10d box x or „ x ls 12" o.c. face nail Double top plate splice for SDCs 8-16d common (3 1/2" x 0.162"); or Face nail on each A-D2 with seismic braced wall line 12-16d box (3 1/2" x 0.135"); or 12-10d of end joint sidTmum 13 spacing < 25' box (3" x 0.128"); or 12-3" x 0.131" nails (mi 24" lap splice Iengtn eac Double top plate splice s UO, D1, or D2; and braced wall line spacing >_ 12-16d (3 1/2" x 0.135") side of end joint) Bottom plate to joist, rim joist, band 16d common (3 1/2" x 0.162") 16" o.c. face nail 14 joist or blocking (not at braced wall panels) 16d box x 5 ; 12" o.c. face nail r „ x nails Bottom plate to joist, rim joist, band 3-16d box (3 1/2" x 0.135"); each o.c. face 15 joist or blocking (at braced wall or 2-16d common (3 1/2" x 0.16211); nail 2 each 16" o.c. panel) or 4-3" x 0.131" nails face nail 4 each 16" ace nail 4-8d box x ; or - ox (3 1/2" x 0.135"); or 4-8d common (2 1/2" x 0.131 "); or 4-10d box (3" x Toe nail 16 Top or bottom plate to stud 0.128"); or 4-3" x 0.131" nails 3-16box 3 1/2" x 0.1 5" ; or 2-16d common (3 1/2" x 0.162"); or 3-10d box End nail 3" x 0.128" ; or 3-3" x 0.131" nails 17 Top plates, laps at corners and - box x ; or - common (3 1/2" x 0.162"); Face nail intersections 3-8d box 2 1/2" x U.113" ; or 2-8d 18 1" brace to each stud and plate common (2 1/2" x 0.131 "); or 2-10d box Face nail 3" x 0.128" ; or 2 sta les 1 3/4" �3-bd box x ; or - 19 1" x 6" sheathing to each bearing common (2 1/2" x 0.131 "); or 2-10d box Face nail (3" x 0.128"); or 2 staples, 1" crown, 16 ga., 1 3/4" Ion 3-8d box 2 1/2" x 0.113" ; or 3-8d common (2 1/2" x 0.131 "); or 3-10d box (3" x 0.128"); or 3 staples, 20 1" x 8" and wider sheathing to each 1" crown, 16 a., 1 3/4" Ion Face nail I er than x - box x bearing 0.113"); 3-8d common (2 1/2" x 0.131"); or 3-10d box (3" x 0.128"); or 4 staples, 1" crown, 16 ga., 1 3/4" Ion FLOOR 4-8d box 2 1/2" x 0.113" ; or 3-8d 21 Joist to sill, top plate or girder common (2 1/2" x 0.131 "); or 3-10d box Toe nail 3" x 0.128" ; or 3-3" x 0.131" nails 8d box (2 1/2" x 0.113") 4" o.c. toe nail Rim joist, band joist or blocking to sill 8d common 2 1 2" x 0.131" ; 22 or top plate (roof applications also) or 10d box (3" x 0.128"); 6" o.c. toe nail r "x .1 1"n it 3-8d box x ; or - 23 1" x 6" subfloor or less to each joist common (2 1 /2" x 0.131 "); or 3-10d box Face nail (3" x 0.128"); or 2 staples, 1" crown, 16 ga., 1 3/4" Ion 24 2" subfloor to joist or girder 3-16d box 3 1/2" x U.135" ; or 2-16d Blind and face nail common 3 1/2" x 0.162" 2" planks 3-16d box (3 1/2" x 0.135"); or 2-16d At each bearing, face 25 (plank & beam -floor & roof) common (3 1/2" x 0.162") nail - common x -10 Band or rim joist to joist box (3" x 0.128"), or 4-3" x 0.131" nails; End nail or 4-3" x 14 ga. staples, 7/16" crown Nail each layer as 20d common (4" x 0.192") follows: 32" o.c. at top and bottom and staggered. Built-up girders and beams, 2-inch 24" o.c. tace nail at 27 lumber layers 10d box (3" x 0.128"); top and bottom or 3" x 0.131 " nails staggered on opposite sides nd: 2-20d common x Face nail at ends and or 3-10d box (3" x 0.128"); at each splice 4ils r3 -16d box 3 1 2" x 0.135' ; or 3-16d 28 Ledger strip supporting joists or common (3 1 /2" x 0.162"); or 4-1 box At each joist or rafter, rafters 3" x 0.128" ; or 4-3" x 0.131" nails face nail 29 Bridging to joist 2-10d (3" x 0.128") Each end, toe nail SPACING OF FASTENERS ITEM DESCRIPTION OF BUILDING NUMBER AND TYPE OF FASTENER a, Intermediat ELEMENTS b, c Edges e supports (inches)h e (inches) Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing [see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing] 6d common (2" x 0.113") nail 30 3/8"- 1/2" (subfloor, wall) 8d common 6 12f (21/2" x 0.131") nail (roof) 31 19/32" - 1" 8d common nail (21/2" x 0.131") 6 12f 10d common (3" x 0.148") nail; or 8d 32 11/8" - 11/4" (21/2" x 0.131 ") deformed nail 6 12 Other wall sheathing 1/2" structural cellulosic fiberboard 1 1/2" galvanized roofing nail, 7/16" head 33 sheathing diameter, or 1" crown staple 16 ga., 1 3 6 1/4" long 25/32" structural cellulosic fiberboard 1 3/4" galvanized roofing nail, 7/16" head 34 sheathing diameter, or 1" crown staple 16 ga., 1 3 6 1/4" long 1 1/2" galvanized roofing nail; staple 35 1/2" gypsum sheathings galvanized, 1 1/2" long; 1 1/4" screws, 7 7 Type W or S 1 3/4" galvanized roofing nail; staple 36 5/8" gypsum sheathings galvanized, 1 5/8" long; 1 5/8" screws, 7 7 Type W or S Wood structural panels, combination subfloor underlayment to framing 6d deformed (2" x 0.120") nail; or 8d 37 3/4" and less common (2 1/2" x 0.131") nail 6 12 8d common (2 1/2" x 0.131") nail; or 8d 38 7/8" - 1" deformed (2 1/2" x 0.120") nail 6 12 10d common (3" x 0.148") nail; or 8d 39 1 1/8"- 1 1/4" deformed (2 1/2" x 0.120") nail 6 12 DESIGNS, INC. ONE STOP SOLUTION ARCHITECTURAL -STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESS AL WORK Ap 1BURVICU GARDEN GROVE, CA92840 PER B �� �N1UANm E THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO TUNG VO, M.S., P.E. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED r I D. OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY TUNG VO, M.S., P.E. R E V I S I O N DATE BY 1 2 3 4 5 VJ W O J Z J a W� Z W� CD U �D I..L PP� VJ O O ti N O Cc U O LL Q ca W N � Q � O Q W 0 O Z Z LU O U) U) LUCc 0 O a U O O PLOTE DATE: 10/31/2024 DRAW BY: DUY NGUYEN PROFESS /� � G THAN y C 69546 2 Luo Exp:06/30/26 Cr 2 OF JOB NO.: 24077 SHEET NO.: S0.0 5 4 3 1 2 R E V I S I O N DATE BY 11122 BIXLER CIR., BUS: 714-928-2006 EMAIL: TUNGCIVIL2018@GMAIL.COM GARDEN GROVE, CA92840 FAX: 714-901-9535 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO TUNG VO, M.S., P.E. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY TUNG VO, M.S., P.E. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PDC Pr o j e c t A d d r e s s : 4 0 1 W J o n q u i l R d , U n i t # 2 , S a n t a A n a , C A 9 2 7 0 6 RE S I D E N T I A L P R O J E C T F O R SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 24077 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 10/31/2024 NE W A D U 1 2 3 4 6 TYPICAL FLOOR/ROOF OPENING DETAIL PROVIDE EDGE NAILING TO ALL EDGES OF OPENING. DOUBLE JOIST OR RAFTER EACH SIDE OF OPENINGPER SCHEDULE SIMPSON HANGER BLOCKING WHERE (PROVIDE FILLER REQUIRED)NOTE: JOIST OR RAFTER SEE PLAN OPENING SEE PLAN BEAM OR GIRDER 8'-0" MAX. 4' - 0 " M A X . TYPICAL CONNECTION DETAIL SIMPSON A34 2x STUD AT EACH SIDE w/ 16d AT 12"o.c. STAGGERED EACH SIDE OF POST @ PROVIDE SIMPSON (4)A35 HI & LOW TOP PLATE. POST PER PLAN CEILING JOIST PARALLEL TO WALL NEW CEILING JOIST PER PLAN. 2x8 LEDGER w/ (2) 16d'S NAIL @ 16" OC INTO STUDS STUDS WALL CEILING JOIST PERPENDICULAR TO WALL NEW CEILING JOIST PER PLAN. 2x8 LEDGER w/ (2) 16d'S NAIL @ 16" OC INTO STUDS SIMPSON HANGER JOIST.1/2" DRYWALL AT BOTTOM OF CEILING JOISTS CEILING JOIST TO WALL DETAIL PERPENDIULAR TO ROOF FRAMING PARALLEL TO ROOF FRAMING 2x STUD SEE ARCH'L FOR SIZE AND SPACING 1/ 4 " ~ 1 / 2 " CL R . 1/ 4 " ~ 1 / 2 " CL R . 2x6 BLOCKING W/SIMPSON "LUS" HANGER EA. END SIMPSON "DTC" CLIP @48"o.c. SIMPSON "DTC" CLIP @48"o.c. CEILING SEE ARCH'L (2)2x TOP ~P'S CEILING JOIST TYPICAL NON-BEARING PARTITION WALL AT ROOF FRAMING DETAIL 9 10 11 STUD NOTCHING AND BORING DBL. TOP PLATES STUD, TYP. BORED HOLE MAX. DIAMETER 40% OF STUD DEPTH 5/8 " MIN. TO EDGE NOTCH MUST NOT EXCEED 25% OF STUD DEPTH BORED HOLES SHALL NOT BE LOCATED IN THE SAME CROSS SECTION OF CUT OR NOTCH IN STUD IF HOLE IS BETWEEN 40% AND 60% OF STUD DEPTH THEN STUD MUST BE DOUBLE AND NO MORE THAN TWO SUCCESSIVE STUDS ARE DOUBLE AND SO BORED 25% 40%5/8 " D NOTCH/BORE % OF STUD 2x4 STUDS 2x6 STUDS 2x8 STUDS 25% 40% 60% 7/8" 1-3/8" 2" 1-3/8" 2-1/8" 3-1/4" 1-3/4" 2-7/8" 4-1/4" DBL. TOP PLATES STUD, TYP. BORED HOLE MAX. DIAMETER 60% OF STUD DEPTH 5/8" MIN. BORED HOLES SHALL NOT BE LOCATED IN THE SAME CROSS SECTION OF CUT OR NOTCH IN STUD TO EDGE NOTCH MUST NOT EXCEED 40% OF STUD DEPTH 40% 60% MIN. D D60% MIN.D D D 60%D5/8 " D 12 13 ROOF/FLOOR DIAPHRAGM LAYOUT FIELD NAILING EDGE NAILING AT ALL BLOCKED EDGES BLK'G. AT DIAPHRAGM EDGES EDGE NAILING BLOKED SHT'G. UNBLOKED SHT'G. SHEATHING ABOVE FRAMING MEMBERS BELOW FIELD NAILING EDGE NAILING NO EDGE NAILING AT UNBLOCKED EDGES NOTE: 1.SEE SHEET SD0 EOR PLYWOOD THICKNESS, NAILING AND ADDITIONAL NOTES. 2.PANELS SHALL NOT BE LESS THAN 4 FT. X 8 ET. EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MINIMUM PANEL DIMENSIONS SHALL BE 24" UNLESS ALL EDGES OF THE UNDERSIZED PANELS ARE SUPPORTED BY FRAMING MEMBERS OR BLOCKING. 3.LONG DIMENSION OF PLYWOOD SHALL RUN ACROSS (PERPENDICULAR TO) JOISTS OR RAFTERS. 4.NAILS SHALL NOT BE DRIVEN THROUGH OUTER PLY. 5.BLOCKED SHT'G. (WHERE INDICATED) REQUIRES ALL PANELS EDGES TO RECEIVE EDGE NAILING. 6.WHERE JOISTS OR RAFTERS LAP SPLICE OCCURS AND PLYWOOD JOINT IS CONTINUOUS. VENEER TO WOOD WALL STEEL ANGLE SCHEDULE SIZE L4x3 1/2x3/8 L6x3 1/2x1/2 L7x4x5/8 8'-0" 14'-0" 16'-0" EXTERIOR SHEATHING SEE ARCH. FOR INSULATION AND MEMBRANE STUD WALL PER PLAN BEAM OR HEADER PER PLAN 1/2" DIA. LAG SCREW @12" O.C. WITH 2.5" MIN. EMBED TO BEAM OR HEADER LLV STEEL ANGLE SUPPORT 3'-6" VENEER HEIGHT MAX AND NEED TO EXTENT AND BEAR ON EACH SIDE OF OPENING 4" MIN. SEE SCHEDULE FOR SIZE FERO PAC-TIE WITH 2-#6 x 2" DECK SCREW AND WASHERS AS FOLLOWS: - TYPICAL AT 16" HORIZONTAL AND AT 24" VERTICAL - AROUND OPENINGS AT 12" HORIZONTAL AND AT 16" VERTICAL - NOT MORE THAN 12" FROM EDGE OF OPENINGS. - LOCATE ROW OF TIES MAX 12" ABOVE BEARING LEVEL AND 8" FROM TOP OF WALL. ADD 9 GAUGE WIRE JOINT REINF. @24" O.C. VERTICAL FOR BUILDING IN SEISMIC DESIGN CATEGORIES C, D, E, F.OPENING SPAN MAX. DRILLING HOLES AND NOTCHING OF THE JOIST D 13 SPAN HOLES AND NOTCHES ALLOWED 13 SPAN HOLES AND NOTCHES ALLOWED 13 SPAN HOLES AND NOTCHES ALLOWED D/3 (RAFT. OR C.J.) D/4 (FLOOR JOIST) D/ 6 D/ 6 MIN. 12"D/ 3 MI N . 2" MI N . 2" D D/ 4 ALTERNATE BOTTOM NOTCH NOTE: 1.DO NOT NOTCH BOTH TOP AND BOTTOM SURFACES WITHIN THE SAME 1/3 SPAN. 2.MAX. ALLOWED IS A COMBINATION OF TWO NOTCHES AND/OR HOLES PER 1/3 SPAN. 3.THIS DETAIL DOES NOT APPLY TO NOTCHES AND HOLES IN STRUCTURAL BEAMS, THEY MUST BE SPECIFICALLY DETAILED. 4.NOTCHES AND HOLES ARE NOT ALLOWED IN CANTILEVERED SEGMENTS OF JOISTS. 5.REFER TO MANUFACTURER'S RECOMMENDATIONS FOR NOTCHES AND HOLES WHERE I-JOIST TRUSSES ARE USED. 6.ANY OVER CUTS ARE TO BE INCLUDED IN THE MAXIMUM NOTCH DEPTH DIMENSION. JOIST SIZE MAX. NOTCH DEPTH: D/4 MAX. NOTCH DEPTH: D/6 MAX. SIZE HOLE: D/3 2X6 2X8 2X10 2X10 2X14 1-3/8" 1-3/4" 2-1/4" 2-3/4" 3-1/4" 7/8" 1-1/8" 1-1/2" 1-7/8" 2-1/8" 1-1/2" 2-3/8" 3" 3-3/4" 4-3/8" UPPER TOP PLATE 3/8" TYP. SHEAR WALL PENETRATIONS SHEAR WALL NAILING SHEATHING PER PLAN FIELD NAILING 6" M I N . HOLES TO BE MIN. 6" FROM PLATES, TYP. FOR HOLES UP TO 16" SQ., PROVIDE BLKG. AND E.N., HOLES LESS THAN 5" SQ. DO NOT REQUIRE BLKG. OR E.N. EDGE NAILING PER PLAN, TYP. FRAMING MEMBER PER SHEAR WALL SCHEDULE 1.SHEAR WALL EDGE NAILING TO HAVE MIN. EDGE DISTANCE OF 3/8". 2.WHEN SHEATHING IS NAILED TO TRIMMER, TRIMMER AND KING STUD TO BE STITCH NAILED TOGETHER WITH 16D'S, SPACING TO MATCH EDGE NAILING OF SHEAR WALL. 3.SHEAR WALL PENETRATIONS ARE TO BE IN CONFORMANCE WITH THE DETAIL BELOW. LIMIT ONE PENETRATION GREATER THAN 5" SQUARE PER STUD BAY. CUTS TO BE MINIMUM 16" FROM EDGE OF SHEAR WALL, ALL DIRECTIONS. 4.CONTACT ENGINEER OF RECORD FOR HOLES LARGER THAN 16" SQUARE. 5.TOTAL LENGTH OF OPENINGS SHALL NOT EXCEED 20% OF THE TOTAL WALL LENGTH. PRESSURE TREATED SILL PLATE w/ A.B.'s PER SHEAR WALL SCHEDULE HOLDOWN AS OCCURS, TYP. 2x STUD TYP. MIN 3x POST AT SHEAR WALL TYPES 1, 2 & 3. SHEAR PANEL w/ E.N. PER PLAN, MIN. WIDTH OF PANEL = 16" 2x4 STUDS AT 16"O.C. TYP., U.N.O. HDR. 6" DEEP & LESS PROVIDE (2) 16d, TRIM. TO HDR., ADD (1) 16d FOR EA. ADD'L 2" OF DEPTH USE LTP4 EA. SIDE WHEN GREATER THAN 2x KING POST 2x KING STUD AT NO HOLDOWN CONDITION OR POST PER PLAN AT HOLDOWN CONDITION. PER TABLE ABV. HEADER PER PLAN 2x TRIM. U.N.O. STITCH NAIL w/ 16d AT 6" o/c AT SHEAR WALLS, 16d AT 12" o/c AT NON-SHEAR WALLS E.N. PER SHEAR WALL SCHEDULE HOLDOWN AS OCCURS MIN. 1/8" STAGGER AT 2" E.N. FRAMING PLATE E.N. INTO UPPER TOP PLATE 1/8" 3/8"3/8" TYPICAL WALL FRAMING5 SHEAR WALL/ INTERSECTION PLYWOOD AT INTERSECTION w/ POST POST AT PER PLAN INTERSECTION w/o POST 16d @ 12" O.C. OUTSIDE CORNER w/ POST NOTE: SEE FRAMING PLAN FOR SHEAR WALL LOCATIONS, ORIENTATIONS AND SCHEDULE REFERENCES DOUBLE 2x, MIN. OUTSIDE CORNER w/o POST DOUBLE-SIDED WALL POST AT PER PLAN 16d @ 12" O.C.16d @ 12" O.C. FOR 2x STUD 20d @ 6" O.C. FOR 3x STUD PLY. CONT. THRU WALL INTERSECTION ATDOUBLE-SIDED WALL 16d @ 12" O.C. FOR 2x STUD 20d @ 6" O.C. FOR 3x STUD 2x OR 3x STUD AS REQ'D., TYP. PER S.W. SCHED. 7 8WOOD SHEARWALL SILL PLATE ANCHORAGE SHEARWALL WHERE OCCURS SILL PLATE ANCHORAGE PER SHEARWALL SCHEDULE CONCRETE SLAB OR PRECAST PLANK SHEARWALL SHEATHING SEE PLAN AND SCHEDULE PLATE WASHER 3 GA x 3 x 3- .229" MIN THICKNESS 12" MAX12" MAX E.Q.E.Q. 2x4 SHEAR WALLS AND ALL DOUBLE SIDED SHEAR WALLS TYPICAL NON-BEARING PARTITION WALL AT ROOF FRAMING DETAIL PERPENDIULAR TO TRUSS FRAMING PARALLEL TO TRUSS FRAMING 2x STUD SEE ARCH'L FOR SIZE AND SPACING 1/ 4 " ~ 1 / 2 " CL R . CL R . SIMPSON "DTC" CLIP @48"o.c. CEILING SEE ARCH'L (2)2x TOP ~P'S TRUSS BOTTOM CHORD 1/ 4 " ~ 1 / 2 " 2x6 BLOCKING W/SIMPSON "LUS" HANGER EA. END SIMPSON "DTC" CLIP @48"o.c. TYPICAL NON-BEARING PARTITION WALL AT SAWN LUMBER FRAMING DETAIL FLOOR JOIST PARALLEL TO WALL FLOOR JOIST PERPENDICULAR TO WALL 2x BLOCKING @ 24"o.c. (2)16d TOE NAIL AT JOIST TO PLATE 2x BLOCKING (CONT.)(2)16d TOE NAIL 16d @ 24"o.c.16d @ 16"o.c. TOP PLATE SPLICING, NOTCHING & BORING STANDARD PLATE SPLICE CONDITION ALL EXTERIOR, BEARING OR SHEAR WALLS, U.N.O. ON PLAN PLATE SPLICE COND. PER PLAN NON-LAPPED CHANNEL CONDITION ALLOWABLE TOP PLATE NOTCHING AND BORING ALL EXTERIOR BEARING OR SHEAR WALLS 2X UPPER TOP-PLATE (12)- 16d P-NAIL (GUN) EACH SIDE OF SPLICE, U.N.O. (ALT. CS16x36")^3 2X LOWER TOP-PLATE LOCATE STUD AT ALL SPLICES TYPICAL UPSIZED CONDITION WHERE SPECIFICALLY INDICATED ON PLANS ST OR MST TYPE STRAP MUST BE PLACED ON TOP OF UPPER PLATE THE NUMBER OF SPLICES MAY BE REDUCED BY NOT CUTTING PLATES AT INTERIOR WALL INTERSECTIONS THE NUMBER OF SPLICES MAY BE REDUCED BY NOT CUTTING PLATES AT INTERIOR WALL INTERSECTIONS SHIM W(2) - 16d (AT 1X PLATE COND. ONLY) FOR HEIGHT ADJUSTMENT LTP4 PER INTERSECTION CONT. 2-2X TOP PLTS. EXTERIOR WALL 1X OR 2X PLATE 2X STUD AT CHANNEL EQ.EQ. REQUIRED TOP PALTE SPLICE (PER PLAN) STANDARD ST6224 MST48 CONT. DBL. TOP PLATES "NOTCH/BORE" DIMENSION OR +B2 B1 4,5 2,3 STRAP NOT REQUIRED STRAP REQUIRED PLAN VIEW PLAN VIEW ST6236 1 MIN. 1-1/4" MIN. 1-3/4" MIN. 2-5/8" MIN. 3-1/2" MIN. 2-3/4" MIN. 1/2" to 1-1/4" MIN. 1-3/8" to 2-5/8" MIN. 1/2" to 1-3/4" MIN. 2-3/8" to 3-1/2" (1) - CS16 (1) - CS16 (1) - CS16 (1) - CS16 CALL ENGINEER MAX. 2" .2" TOP PLATES "NOTCH/BORE" CS16 W/(12)-8d NAILS ON EACH SIDE (WHERE REQ'D. BY CHART ABOVE)NOTCH CONDITION BORE CONDITION 1 6" A A B1 B2 48" MINIMUM LAP 14 TY P I C A L D E T A I L S S0.1 FRAMING SCHEDULE PAD SCHEDULE PAD 2'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W. SYM. F2.0 2'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W. 3'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W. F2.5 F3.0 LEGEND 3'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F3.5 DESCRIPTIONSYM. F2.0 POST OR TRIMMER AS NOTED SDX X PAD NUMBER DETAIL NUMBER DETAIL SHEET NUMBER X'-X" X DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION) SHEAR PANEL LENGTH AND NUMBER, STRAP & POST EACH THE END SHEARWALL PER SHCEDULE & PLAN. REFER TO SD-0 FOR PANEL TYPE, MIN. 2-2x4 @ EA. END. INDICATES ROOF TRUSSES BY TRUSS SUPPLIER INDICATES FLOOR JOISTS BY JOIST SUPPLIER,OR U.N.O PER SCHEDULE & PLAN INDICATES DECK JOIST OR ROOF RAFTER PER SCHEDULE & PLAN X BEAM NUMBER, REFER TO REPORT CALCULATIONS KEY NOTE NUMBER BEARING WALL CALIFORNIA FRAMING XX GREATE BEAM @ FOUNDATION SEE PLAN FOR SIZE KEY NOTES FJ RR RT X NUMBER OF ANCHOR BOLTS LINE OF 2X FLAT BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER U.N.O. SEE PLAN FOR NUMBER OF BAYS. BLOCKED FLOOR DIAPHRAGM W/ 10d's @ 4" O.C. B.N., 4" O.C. E.N. & 12" O.C. FIELD. BLOCKED ROOF DIAPHRAGM W/ 8d's @ 4" O.C. B.N., 4" O.C. E.N. & 12" O.C. FIELD. PROVIDE SOLID BLOCKING TRUSS HANGER BY TRUSS SUPPLIER CONTINUOUS FULL HT. BLKG. W/E.N. SEE PLANS FOR NUMBER OF BAYS ( U.N.O.) 1 2 3 4 5 6 EXISTING SLAB & FOOTING INDICATES CEILING JOIST PER SCHEDULE & PLANCJ NEW FOOTING SYMBOL SIZE MAX. SPACING U.N.O RR 2X8 RR 16" O.C. 4'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F4.0 4'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F4.5 NEW SLAB CONSTRUCTION NOTES 1.REFER TO STRUCTURAL GENERAL NOTES AND DETAIL SHEETS (S0.0 & S0.1) FOR MORE INFORMATION. 2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING PREFABRICATED SHEAR WALLS AND MATCH TOP PLATE HEIGHT AND WALL WIDTH AND NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS. 3.AS AN ALTERNATE TO USING SIMPSON PRODUCTS OTHER CONNECTORS CAN BE USED, AS LONG AS THEIR CAPACITIES ARE EQUAL TO OR BETTER THAN SIMPSON'S. 4.USE SIMPSON " IUS " HANGERS FOR CONNECTION OF I-JOISTS TO OTHER FRAMING MEMBERS (U.N.O.) AND " LUS " HANGERS FOR CONNECTION OF SOLID JOISTS. 5.USE ST6224 STRAP FOR THE TOP PLATES SPLICE AT ROOF FRAMING LEVELS (5B/SD2.0), UNO ON PLANS. 6.USE ST22 STRAP FOR LEDGER SPLICES, UNO. 7.USE (1)CS16 X 3'-0" STRAP AT RIM JOISTS SPLICE, U.N.O ON PLANS. 1¼” MIN. LVL RIM JOISTS SHOULD BE USED AT ALL FLOOR FRAMING EDGES. 8.PLYWOOD IS APPLIED ON EITHER SIDE OF SHEAR WALLS 9.INTERIOR NON-BEARING WALLS MAY BE FRAMED WITH 2X STUDS AT 24" O.C., MAX. 10.HEARDER AT OPENING AT EXTERIOR & INTERIOR BEARING WALL SHOULD BE MIN. 4X6 ,U.N.O 11.HEADER AT NON-BEARING WALLS, USE 2X4 FOR OPENINGS UP TO 3'-0" MAX., (2)2X4 FOR OPENINGS UP TO 6'-0" MAX., 4X6 FOR OPENINGS UP TO 12'-0" MAX., (UNO). 12.2X6 WALL SHOULD BE AT PLUMPING WALL. 13.TOTAL MINIMUM NUMBER OF ANCHOR BOLTS. REQUIREMENTS. FOR NON-SHEAR WALLS, MASA/MASAP MUDSILL ANCHORS CAN BE USED IN LIEU OF ANCHOR BOLTS WITH END DISTANCE OF 4" MIN. PER ESR #2555. 14.FOUNDATION ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. 15.SIMPSON SET-XP EPOXY ESR-2508 SPECIAL INSPECTION REQUIRED 16" O.C.CJ 2X10 CJ BATH 2 BATH 1 W/D WH BEDROOM 1 BEDROOM 2 BEDROOM 3 DINING LIVING REF. KITCHEN PANTRY HD U 2 2 HD U 2 2 4'-0" 1 SD1 2 SD1 5 SD1 HDU2 HDU2 3 2 8' - 0 " 5 SD1 1 SD1 2 SD1 3 2 9' - 0 " 1 SD1 2 SD1 5 SD1 HDU2 HDU2 2 1 SD1 2 SD1 5 SD1 2 4' - 9 " HDU2 HDU2 2 2 6' - 0 " 1 SD1 2 SD1 5 SD1 HD U 2 3 HD U 2 2 8'-0" 5 SD1 TYP. 1 SD1 2 SD1 HD U 4 HD U 4 2 3 6'-0" 2 SD1 1 SD1 5 SD1 MIN.5" THK. CONC. SLAB w/ #4 @ 12" O.C. EA WAY OVER 2" SAND OVER 10 MIL. VAPOR BARRIER OVER 4" AGGREGATES OF 1/2" OR LARGER SLAB AREA 3 SD1 TYP. 9 SD1 TYP. 15 " 15" 15 " F2.0 F2.0 F2.0 F2.0 11 SD1 10 SD1 HDU2 HDU2 12 ' - 5 " 10'-8"5'-3" TYP. TYP. 10 ' - 9 " 15" 15 " BATH 2 BATH 1 W/D WH BEDROOM 1 BEDROOM 2 BEDROOM 3 DINING LIVING REF. KITCHEN PANTRY 4X6 4X6 4X 8 4X 6 4X 6 4X64X6 4X 6 4X64X6 4X 6 4X 6 RR RR RR RR 2 4'-0" 2 8' - 0 " 2 9' - 0 " 2 4' - 9 " 2 6' - 0 " 2 8'-0" 3 6'-0" 4X 4 4X 4 4X 4 4X 4 4X4 4X4 4X 4 4X4 4X4 4X4 1 SD2 5A SD2 4X 4 R1 4X64X6 CJ 4X4 R2 4 5 1/4"X14" PSL CL'G BM 2 SD2 5A SD2 5B SD2 2 SD2 1 SD2 5B SD2 2 SD2 5A SD2 4 SD2 TYP. 5B SD2 13 SD2 13 SD2 5A SD2 2 1 3 A B C 7 SD2 TYP. 10 S0.1 TYP. 1 2 3 4X 4 / K . P . 3 1/2"X11 7/8" LSL R.B.CONT. 3 1/2"X11 7/8" LSL R.B. 4X 1 0 4X 1 0 4X 1 2 R . B . CJ 4X6 5 4X4/K . P . 4X 4 / K . P . 11 SD2 W/ECCQ44 8 SD2 W/CCQ44 8 SD2 W/CCQ44 11 SD2 W/ECCQ44 10 SD2 TYP. 7 SD2 TYP. 8 SD2 11 SD2 LOW.HI. 8 SD2 4X6 6 SD2 4X6 6 SD2 4X4 4X4 2-2X4 TRIM 4X6 15A SD212 SD2 14B SD2 (L=±15'-9") 5 4 3 1 2 R E V I S I O N DATE BY 11122 BIXLER CIR., BUS: 714-928-2006 EMAIL: TUNGCIVIL2018@GMAIL.COM GARDEN GROVE, CA92840 FAX: 714-901-9535 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO TUNG VO, M.S., P.E. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY TUNG VO, M.S., P.E. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PDC Pr o j e c t A d d r e s s : 4 0 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 RE S I D E N T I A L P R O J E C T F O R SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 24077 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 10/31/2024 NE W A D U FO U N D A T I O N P L A N & F R A M I N G P L A N S1.0 ROOF FRAMING PLAN SCALE : 1/4" = 1'-0" FOUNDATION PLAN SCALE : 1/4" = 1'-0" SOIL ENGINEER'S CERTIFICATE: This plan has been reviewed and conforms to recommendations of the soil report prepared for this development. 3-31-233-31-253/31/273/31/27 4/16/2025 5 4 3 1 2 R E V I S I O N DATE BY 11122 BIXLER CIR., BUS: 714-928-2006 EMAIL: TUNGCIVIL2018@GMAIL.COM GARDEN GROVE, CA92840 FAX: 714-901-9535 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO TUNG VO, M.S., P.E. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY TUNG VO, M.S., P.E. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PDC Pr o j e c t A d d r e s s : 4 0 1 W J o n q u i l R d , U n i t # 2 , S a n t a A n a , C A 9 2 7 0 6 RE S I D E N T I A L P R O J E C T F O R SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 24077 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 10/31/2024 NE W A D U 1 2 3 47 8 INTERIOR PARTITION, TYP. 2x P.T D.F SILL PLATE w/ 7 32"Øx312" SHOT PINS @ 32" OC w/ 14 GA PER ICC-ESR 2138 . WASHERS AND FIRST 2 PINS PLACED 6" AND 10" FROM PLATE ENDS CONCRETE SLAB 2x STUDS @ 16" OC 2x P.T D.F SILL PLATE w/ 7 32"Øx312" SHOT PINS @ 32" OC w/ 14 GA PER ICC-ESR 2138 . WASHERS AND FIRST 2 PINS PLACED 6" AND 10" FROM PLATE ENDS CONCRETE SLAB 2x STUDS @ 16" OC BEARING NONE SHEAR WALL NONE BEARING CONCRETE FOOTING SIZE & REBARS PER DETAIL 1/SD1 W PER SCHEDULE PE R S C H E D U L E SE E D E T A I L 1 / S D 1 TYP. REINFORCING DETAILS BEND R= 5(d) FOR #14 THRU #18 LAP SPLICE STIRRUP 6(d ) M I N . TIE OR HOOK 6(d ) M I N . MADE COLD DI M E N S I O N DE T A I L I N G OR 3 " M I N . - ALL BENDS SHALL BE STIRRUP ALT. 135° BENDS - PUT CROSSTIE W/ EACH D= 4(d) FOR #3 THRU #5 D= 6(d) FOR #6 THRU #8 OR 3 " M I N . 12 ( d ) F O R # 6 T H R U # 8 DI M E N S I O N DE T A I L I N G NOTES: CROSSTIE MEMBER BELOW, EXCLUDE CONCRETE IS CAST IN THE THAN 12 INCHES OF FRESH BARS SO PLACED THAT MORE FOR TOP BARS (HORIZONTAL * INCREASE LENGTH BY 30% WIRE TIE END WALLS) D D 48(d) MASONRY (U.N.O.) 48(d) * IN CONCRETE 90° BEND 8(d) R R= 4(d) FOR #9 THRU #11 R= 3(d) FOR #3 THRU #8 2 1/2" MIN.8(d) 180° BEND R12 " 4(d) OR 4" M I N . O R 4" M I N . O R 6(d ) STAIR OR RAMP ON GRADE 2" #3 NOSING TYPICAL SEE ARCH. FOR TREAD AND RISERS 6" MIN . (2)#5 CONT. #4@12 EACH WAY #4@12 RAMP LINE #4@12 1'-6" 2'-0" 1'-2" 1' - 6 " M I N . 1'-6" 2'-0" TYPICAL MANDATORY MINIMUM FORMWORK (UNLESS FULLY FORMED) CLEAN OUT ON DWGS. +2" WIDTH SHOWN LAITANCE AND SCUM HAS SET. REMOVE AFTER CONCRETE NOTE: NOTE: 6" MIN 11/2" MIN. STARTER WALL REQUIRED FOR FOOTINGS CURB OR STARTER WALL BELOW GRADE LC APPLICABLE FORMWORK SPECIFICATIONS 2" PLANKING FOUNDATION CONCRETE MAY BE PLACED DIRECTLY INTO NEAT EXCAVATIONS PROVIDED THE FOUNDATION TRENCH WALLS ARE STABLE AS DETERMINED BY THE ARCHITECT (STRUCTURAL ENGINEER), SUBJECT TO THE APPROVAL OF THE DIVISION OF THE STATE ARCHITECT, IN SUCH CASE. THE MINIMUM FORMWORK SHOWN ON THE DRAWINGS IS MANDATORY TO INSURE CLEAN EXCAVATIONS IMMEDIATELY PRIOR TO AND DURING THE PLACING OF CONCRETE. STARTER WALL REQUIRED FOR ALL MASONRY OR CONCRETE WALLS. STAKES NOT PERMITTED WITHIN FOOTING SECTION. FORMWORK NOT PERMITTED BELOW GRADE UNLESS FULLY FORMED. TYPICAL 6 5 NEW EXTERIOR FOOTING (2)#5 OR (3)#4 REBAR CONT. T & B (U.N.O.). STUD WALL SHEAR PANEL WHERE OCCURS WITH B.N. AT SILL PLATE 8" MI N . 3" MAX P.T.D.F. SILL PLATE W/ ANCHOR BOLTS PER AB SCHEDULE. (MIN. 5/8" DIAMETER @ 48" O.C.) 3" W PER SCHED. N.G. OR APPROVED COMPACTED FILL #3 @ 24" O.C. BENT 3' INTO SLAB SAND AND VAPOR BARRIER PER PLANS. VAPOR BARRIER. WHERE OCCURS EXTEND 1.1/2" INTO FTG. D1 SLOPE TO DRAIN SCREED 26 GAUGE @ STUCCO FINISH F.G. FOOTING DIMENSIONS # OF STORIES W WIDTH D DEPTH 1 15"24" 2 18"24" MIN.5" THK. CONC. SLAB w/ #4 @ 12" O.C. EA WAY OVER 2" SAND OVER 10 MIL. VAPOR BARRIER OVER 4" AGGREGATES OF 1/2" OR LARGER D1 DEPTH 8" 8" D M I N . PE R S C H E D . D P E R S C H E D . 24 " M I N . TYPICAL ANCHOR BOLT DETAIL BA 7" M I N . A = MIN. EDGE DISTANCE FROM SILL PLATE TO BOLT C.L. FROM SLAB EDGE TO BOLT C.L. B = MIN. EDGE DISTANCE BOLT DIAM. 5/8" 7/8" 3/4" 7/8" 3/4" BOLT DIAM. 5/8" N.A. N.A 4" (NOMINAL) WALLS A 1" N.A. N.A. B 1.7/8" 1.3/8" 1.1/8" 6" (NOMINAL) WALLS A 1" 2.1/4" 2" B 1.7/8" HOLDOWN @ NEW FOOTING SSTB BOLTS INSTALLATION @ SW @ EXT. FOOTING HUD2/HDU4/HDU8/HDQ8 HOLDOWN w/ SDS2.5 SCREWS (MIN) 1 3/4" ANCHOR BOLT PER SIMPSON CATALOGUE NOTE: SIMPSON SET-XP EPOXY ESR-2508 SPECIAL INSPECTION REQUIRED 3" MAX EF F E C T I V E EM B E D M E N T SIMPSON HOLDOWN HDU5 HDU2 HDU4 SSTB24 SIZES SSTB24 SSTB24 MIN EMBED (le) 20 5 8" 20 5 8" 20 5 8" 3" CL R . SECTION E-E 1.5 le E E BOTTOM OF SLAB. 3" le M I N 1 6 " . CL R . EQ.EQ.MI N . F F le M I N 1 6 " . SECTION F-F 1.5 le SSTB BOLTS INSTALLATION @ SW @ INT. FTG/SLAB (2)#4x8'-0" REBAR CONT. T & B (U.N.O.), CENTERED @ "HD" (BEND REBAR @ CORNER) 3" CL R . CONCRETE END EXTERIOR FOOTING EDGE OF EXTENDED/ENLARGED EXTERIOR FOOTING. BOTTOM OF EXT. FOOTING CONCRETE STEM/FOOTING WIDTH (8" MIN. FOR 7/8"Ø BOLT, 6" MIN. FOR 5/8"Ø BOLT) ENTIRE EMBED. LENGTH. BOTTOM OF EXT. FOOTING EDGE OF DEEPENED SLAB/FTG FOR HOLDOWN @ INT. SHEAR WALL. BOTTOM OF SLAB. FTG WIDTH (13" FOR 7/8"Ø BOLT, 9" FOR 5/8"Ø BOLT). HDU8 SSTB28 24 7 8" HDQ8 SSTB28 24 7 8" ST R U C T U R A L D E T A I L S SD1HOUSE TO PORCH D W 2" MI N . PORCH SLAB SLOPE TO DRAIN 6" MIN. FINISH GRADE 6" MI N . FACE OF STUDS #4 X 24" DOWELS @ 16" O.C. NEW INTERIOR FOOTING TYP. UNLESS NOTED OTHERWISE IN SHEAR WALL SHEDULE EDGE NAILING FOR BOLT INFORMATION SEE DETAIL 1/ SD1, 2x P.T.D.F. SILL PL SHEAR WALL PANEL SEE PLAN WHERE OCCURS SLAB ON GRADE 2x STUDS @ 16"o.c. UNLESS NOTED PER PLAN OTHERWISE W PER SCHEDULE PE R S C H E D U L E SE E D E T A I L 1 / S D 1 3" CLR. 3" C L R . (2)#5 OR (3)#4 REBAR CONT. T & B (U.N.O.). SEE DETAIL 1/SD1 FOR ADDITIONAL INFORMATION. #4 24" X 24" DOWELS @ 36" O.C. 9 TYPICAL PAD AT EXT. WALL FOOTING DETAILS SEE DETAIL 1/SD1 FOR ADDITIONAL INFORMATION. CONTINUOUS FOOTING BEYOND PER PLAN SPREAD FOOTING PER PLAN OF INFORMATION SEE DEAIL 1/SD1 PER PLAN SHEAR WALL FOR REMAINDER SLAB ON GRADE PER PLAN FINISH GRADE SEE PLANS 8" M I N . PA D D E P T H 8" MI N . TYPICAL PAD INTERIOR BEARING WALL FOOTING DETAIL PER PLAN SPREAD FOOTING 2x STUDS @ 16"o.c. UNLESS NOTED OTHERWISE PER PLAN CONTINUOUS FOOTING BEYOND UNLESS NOTED OTHERWISE IN SHEAR WALL SHEDULE SEE DETAIL 1/SD1 , FOR BOLT INFORMATION 2x P.T.D.F. SILL PL SHEAR WALL PANEL EDGE NAILING SEE PLAN WHERE OCCURS SLAB ON GRADE PER PLAN SEE PLANS SP R E A D F O O T I N G D E P T H 10 11 3-31-233-31-253/31/273/31/27 4/16/2025 SOIL ENGINEER'S CERTIFICATE: This plan has been reviewed and conforms to recommendations of the soil report prepared for this development. 5 4 3 1 2 R E V I S I O N DATE BY 11122 BIXLER CIR., BUS: 714-928-2006 EMAIL: TUNGCIVIL2018@GMAIL.COM GARDEN GROVE, CA92840 FAX: 714-901-9535 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO TUNG VO, M.S., P.E. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY TUNG VO, M.S., P.E. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PDC Pr o j e c t A d d r e s s : 4 0 1 W J o n q u i l R d , U n i t # 2 , S a n t a A n a , C A 9 2 7 0 6 RE S I D E N T I A L P R O J E C T F O R SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 24077 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 10/31/2024 NE W A D U 1 2 3 4 POST & BEAM CONNECTION BM., SEE PLAN POST, SEE PLAN. EQ . EQ . STRAP A CAPACITY - 5600# 2900# MSTA12 EA. SIDE (1) CS16B (2) CS16C OF EACH STRAP OVERALL LENGTH 12" 24" 24" SIMPSON STRAP EACH SIDE OF BEAM TO POST. ALT. TO MSTA12 STRAPS, USE 2X KING STUD EACH SIDE OF BEAM TO POST & NAIL W/ 16d'S @ 16" O.C. TO POST & MIN. (5) 16d'S TO BEAM. CALIF. FRAMING DETAIL 2X6 FLAT W/ 2-16d TO EA. ROOF TRUSS/RAFTER RUN LOWER ROOFSHEATHING TO SUPPORTING WALL/BEAM AND PROVIDE SHEAR TRANSFER AT THAT LOCATION 2X4 RR @ CALIFORNIA FRAMING MAX. SPAN = 8' U.N.O. MAIN ROOF FRAMING RAFTER OR ROOF TRUSS ROOF RAFTER ROOF SHEATHING B.N. ROOF RAFTER W/ HANGERS TO RIDGE ROOF SHEATHING 2X6 RIDGE @ 2X4 RAFTERS @ CALIFORNIA FRAMING B.N.B.N. ROOF BRACE WHERE REQ'D TO LIMIT SPANON 2X4 R.R. TO 8'-0" MAX. U.N.O. (2)16d TOENAIL RR TO RR. TYPICAL TOP PLATE SPLICE ST22 STRAP @ RIDGE OF RAKE WALL 18-16d SINKERS @ SPLICE, STAGGERED DO NOT SPLIT TOP PLATE WITH SPLICE NAILING, SEE TABLE BELOW. STUDS @ 16" O.C. 2-16d FROM TOP PLATE TO BOTTOM PLATE OVER EACH STUD 2-16d FROM PLATE TO EA. STUD 2-2X TOP PLATE 4' NOTE: SPLICE REQUIRED AT ALL PLATE BREAKS AND ALSO AT CHANNELS FOR INTERSECTING WALLS AT ANY EXTERIOR WALL, BEARING WALL, OR SHEAR WALL NO. OF 16d SINKER MIN. PLATE LAP ALT. STRAP w/ 16d SINKER ST22 ST6224 ST6236 MST37 MSTC52 CMST12x72" 8 FT. 42 GF 36 8 FT.8 FT. 32 ED 24 6 FT.6 FT. 22 CB 16 4 FT. 10 A 4 FT. MST60 TYPICAL FLUSH BEAM PERPENDICULAR TO WALL DETAIL BEAM PER PLAN POST OR DOUBLE STUDS (PROVIDE 16d @ 12"o.c. AT DOUBLE STUDS) (2)2x TOP ~PS PLYWOOD SHEATHING PER PLAN EACH SIDE FOR BEAMS 9~4" DEEP AND LARGER PROVIDE SIMPSON A35 5 6 7 8 TYPICAL STUD WALL FRAMING AT OPENING DETAIL (2)10d TOE 16d @ 12"o.c. WIDER THAN 6'-0") TRIMMER AT OPENING 2x TRIMMER (2)2x U.N.O. SILL ~P THAN 4'-0") SILL AT OPENING WIDER WHERE OCCURS (2)2x 2x WINDOW SILL SEE PLAN POST AT HOLDOWNS DOUBLE STUDS OR 2x STUDS @ 16"o.c. TOP AND BOTTOM 6'-0") W/ SIMPSON A34 OPENING WIDER THAN (2)2x THRU STUDS AT (1)2x THRU STUD (USE HEADER DEPTH) OF ADDITIONAL (2)16d FOR EA. 2" (2)16d MIN. (ADD THAN 8'-0" OPENING WIDER SIMPSON A34 AT NAILS STAGGER DETAILS SEE CBC, TABLE 25Q, OR FOR BALANCE OF NAILING, U.N.O. ON PLANS) OPENING HEADER SCHEDULE WIDTH 10'-0" 12'-0" 8'-0" 6'-0" 4'-0" MAX. VERTICAL AND @ 8'-0"o.c. STOPS AT CEILING PROVIDE 2x FIRE NOTE: STUD WIDTH WIDTH SAME AS BEARING 10" 12" NON-BEARING 8" 6" 4" 12" 14" 8" 10" 6" MIN. NOMINAL HEADER ''D'' TO 6'-0" ONLY) (AT OPENINGS UP BUILT-UPSOLID '' D ' ' DE P T H HD R UP PER SCHEDULE HEADER (SOLID, BUILT- (2)2x TOP ~PS EA. SIDE STAGGER w/ 16d @ 12"o.c. CONT. PLYWD. SHIM 2x EA. SIDE ANDNOTE: 9 CJ W/ 8-16d FACE NAILS LARGER BLOCK (RIPPED TO CORRECT SIZE) FOR GAPS LARGER THAN 1". USE FULL DEPTH BLKG. INSTALL LS70'S WHERE GAP EXCEEDS 1/4". USE NEXT H1'S @ 24" O.C. MAY BE INSTALLED IN LIEU OF A35'S FOR SHEAR TRANSFER. DROP BM. WHERE OCCURS HEADER WHERE OCCURS 2X BEVELED BLOCKING W/E.N. & A35 @ 24" O.C. (SEE ADDITIONAL A35 REQMTS. @ SHEAR WALLS) DBL 2X TOP PLATE 2X STUDS @ 16" O.C. SHEAR PANEL WHERE OCCURS B.N. SEAT CUT ALL RAFTERS. DO NOT OVERCUT. ALT. LOCATION OF BLKG. NOTES: ROOF SHEATHING RR W/ SEAT CUT AT WALL B.N. ROOF RAFTER PERPENDICULAR TO EXT. WALL 30" MAX. 1X6 STARTER BOARD-SHIPLAP AT EXPOSED EAVES 2X ROSA FASICA SIMPSON H2.5A @ 48" O.C. U.N.O. B.N.:8D COMMON NAIL AT 6" O.C. GABLE END WALL FLUSH RIDGE CONDITION SIMPSON ST22 STRAP @ 48" OC EQ.EQ. ROOF RAFTER W/ HANGERS TO RIDGE DROP RIDGE CONDITION ROOF RAFTER W/ HANGERS TO RIDGE RIDGE PER PLAN. E.N. 2X BLK'G E.N.LAP & SPLICEW/(3) 16d's EACH SIDE GABLE END WALL 2x STUDS BALLOON FRAME 16d NAILS @ 8" OC AFTER ROOF IS LOADED 2x BLOCKING D.F #2 FLAT LOOKOUTS 2x4 @ 24" OC OR 2x6 @ 32" OC. TAKE BACK TO 2ND RAFTER (MAX 18" TOTAL OVEHANG). SOLID SHIM UNDER EA. LOOKOUT HOLD TOP OF WALL DOWN 3 4" + FROM TOP OF UNLOADED RAFTER E.N #FULL HEIGHT SEE PLAN E.N (2)-16d @ EA. END OF LOOKOUT ROOF SHEATHING E.N A35F MAY BE OMITTED WHERE SHEAR WALL MATERIAL APPED +4" OVER RIM. PROVIDE A35F @ NON-SHEAR SEQUENTS E.N E.N SIMP. A35F @ 48" OC DTL 16d 'S A35'S A 8" OC 32" OC B 6" OC 24" OC C 4" OC 16" OC D 3" OC 12" OC NOTCH JOIST FOR LOOKOUTS ALT. DROP BEAM PER PLAN. CEILING JOIST OVER LAP, TYP. 1'-0" CEILING JOIS OVERLAP w/ SPACER AND 4-16d NAILS EA. SIDE 10 11 ST R U C T U R A L D E T A I L S SD2CONNECTION DETAIL BEAM PER PLAN POST SAME WIDTH AS BEAM, SEE PLAN. (2)16d EA. SIDE 2x STUD EA. SIDE OF POST w/ 16d @ 12"o.c. BEAM PER PLAN. ST12 EACH SIDE K. POST TO SUPPORTING BM. SIMP. CCQ MATCH SIZE WITH BEAM, SEE PLAN. 2x STUD EA. SIDE OF POST w/ 16d @ 12"o.c. ALTERNATE CONNECTION DETAIL RIDGE BEAM, SEE PLAN. FULL BEARING POST. R/R LAPPED W/ (4) 16d's. SLOPING DBL TOP PL. ALT. CONDITION WHEN R/R's ARE BUTTING AGAINST EACH OTHER USE ST22 FOR CONNECTION ON TOP. 2X K. STUD W/ (3) 16d's TO SIDE OF BEAM & 16d's @ 12" O.C. TO SIDE OF POST. RIDGE BEAM, SEE PLAN. SIMP.ST6236 STRAP , FULLY NAIL STRAP W/ 16d SINKER OR 10 d's COMMON NAILS SIMPSON A35 @ 24" O.C. ALT. CONDITION ST6236 STRAP, FULLY NAIL STRAP W/ 16d SINKER OR 10 d's COMMON NAILS DRAG DETAIL A CS16 1700# 3'-6" B (2)CS16 3400# 3'-6" END LENGTHSTRAPCAPACITY** CS16 & NAIL W/16d's @ 4" O.C. MEMBER TO RECEIVE 2ND. ADD 2"X4"X48" LONG * STAGGERED TO ROOF * RAFTER/TRUSS TOP CHORD. SIMPSON CS16 W/ (2) ROWS OF 8d SINKER NAILS @ 4 1/8" O.C. CUT TO FIT OVER ALL BAYS OF BLOCKING. WHERE APPLICABLE. TYP. ROOF RAFTER OR TOP CHORD OF TRUSS. 2X FLAT BLK'G. W/ E.N. SEE PLAN FOR NO. OF BAYS (MIN. 4 BAYS). DBL. TOP PLATE OR BEAM. HIP BEAM OR TOP CHORD OF HIP TRUSS. ROOF SHEATHING W/ E.N. ALONG LINE OF DRAG.END L E N G T H . END L E N G T H . END LENGTH. DRAG DETAIL POST OR STUDS CL'G BEAM PER PLAN (2)2x TOP ~PS 2x STUD w/16d @ 12"o.c. MSTA12 AT BOTH SIDE SIMPSON STRAP CUT TO FIT ON WALL AS SHOWN & ACROSS ALL BAYS OF BLKG.AS REQ'D. MIN. (4) BAYS w/ MIN. (3) NAILS TO EACH BLOCK. NAILS PER SCHEDULE, USE (2) ROWS OF NAILS EA. STRAP LENGTH LENGTH CAPACITY** 1700# 3400# 4585# 6490# END LENGTH NAIL SIZE AND SPACINGSTRAP CS16 (2) CS16 CMSTC16 CMST14 A B C* D* 3'-0" 3'-0" 6'-0" 6'-0" 8d BOX/SINKER @ 4 1/8" 8d BOX/SINKER @ 4 1/8" 16d SINKER @ 4 1/2" 16d SINKER @ 3 1/2" TYP. ROOF FRAMING MEMBER (2)2x F.H. BEVELED BLK'G W/EN. U.N.O B.N. B.N. 2X STUDS @ 16" O.C. SHEAR PANEL WHERE OCCURS ROOF SHEATHING RR W/ SEAT CUT AT WALL 2X LOOKOUT W/ 8-16d FACE NAILS B.N. DBL 2X TOP PLATE 1/2" DRYWALL AT BOTTOM OF CEILING JOISTS 2X CEILING JOIST CONNECTION DETAIL SEE DETAIL 1/SD2 FOR ADDITIONAL INFORMATION. RAFTER TO FLUSH BM.CONN. CALIFORNIA FRAMING FLUSH BEAM PER PLAN CEILING RAFTERS PER PLAN ROOF RAFTER SIMPSON HANGER JOIST. A35 @ 24" O.C. CRIPPLE WALL 16d's @ 6" O.C. E.N. 12 13 14 15 CHAPTER 4 RESIDENTIAL MANDATORY MEASURES DIVISION 4.1 PLANNING AND DESIGN DIVISION 4.3 WATER EFFICIENCY AND CONSERVATION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE 4.406.1 RODENT PROOFING. Annular spaces around pipes, electric cables, conduits or other openings in sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency. 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 4.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65 percent of the non-hazardous construction and demolition waste in accordance with either Section 4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local construction and demolition waste management ordinance. Exceptions: 1. Excavated soil and land-clearing debris. 2. Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist or are not located reasonably close to the jobsite. 3. The enforcing agency may make exceptions to the requirements of this section when isolated jobsites are located in areas beyond the haul boundaries of the diversion facility. 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN. Submit a construction waste management plan in conformance with Items 1 through 5. The construction waste management plan shall be updated as necessary and shall be available during construction for examination by the enforcing agency. 1. Identify the construction and demolition waste materials to be diverted from disposal by recycling, reuse on the project or salvage for future use or sale. 2. Specify if construction and demolition waste materials will be sorted on-site (source separated) or bulk mixed (single stream). 3. Identify diversion facilities where the construction and demolition waste material collected will be taken. 4. Identify construction methods employed to reduce the amount of construction and demolition waste generated. 5. Specify that the amount of construction and demolition waste materials diverted shall be calculated by weight or volume, but not by both. 4.408.3 WASTE MANAGEMENT COMPANY. Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with Section 4.408.1. Note: The owner or contractor may make the determination if the construction and demolition waste materials will be diverted by a waste management company. 4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 3.4 lbs./sq.ft. of the building area shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 2 pounds per square foot of the building area, shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.5 DOCUMENTATION. Documentation shall be provided to the enforcing agency which demonstrates compliance with Section 4.408.2, items 1 through 5, Section 4.408.3 or Section 4.408.4.. Notes: 1. Sample forms found in "A Guide to the California Green Building Standards Code (Residential)" located at www.hcd.ca.gov/CALGreen.html may be used to assist in documenting compliance with this section. 2. Mixed construction and demolition debris (C & D) processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle). 4.410 BUILDING MAINTENANCE AND OPERATION 4.410.1 OPERATION AND MAINTENANCE MANUAL. At the time of final inspection, a manual, compact disc, web-based reference or other media acceptable to the enforcing agency which includes all of the following shall be placed in the building: 1. Directions to the owner or occupant that the manual shall remain with the building throughout the life cycle of the structure. 2. Operation and maintenance instructions for the following: a. Equipment and appliances, including water-saving devices and systems, HVAC systems, photovoltaic systems, electric vehicle chargers, water-heating systems and other major appliances and equipment. b. Roof and yard drainage, including gutters and downspouts. c. Space conditioning systems, including condensers and air filters. d. Landscape irrigation systems. e. Water reuse systems. 3. Information from local utility, water and waste recovery providers on methods to further reduce resource consumption, including recycle programs and locations. 4. Public transportation and/or carpool options available in the area. 5. Educational material on the positive impacts of an interior relative humidity between 30-60 percent and what methods an occupant may use to maintain the relative humidity level in that range. 6. Information about water-conserving landscape and irrigation design and controllers which conserve water. 7. Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5 feet away from the foundation. 8. Information on required routine maintenance measures, including, but not limited to, caulking, painting, grading around the building, etc. 9. Information about state solar energy and incentive programs available. 10. A copy of all special inspections verifications required by the enforcing agency or this code. 11. Information from the Department of Forestry and Fire Protection on maintenance of defensible space around residential structures. 12. Information and/or drawings identifying the location of grab bar reinforcements. 4.410.2 RECYCLING BY OCCUPANTS. Where 5 or more multifamily dwelling units are constructed on a building site, provide readily accessible area(s) that serves all buildings on the site and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waster, and metals, or meet a lawfully enacted local recycling ordinance, if more restrictive. Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section 42649.82 (a)(2)(A) et seq. are note required to comply with the organic waste portion of this section. DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY DIVISION 4.5 ENVIRONMENTAL QUALITY 4.303 INDOOR WATER USE 4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the sections 4.303.1.1, 4.303.1.2, 4.303.1.3, and 4.303.4.4. Note: All noncompliant plumbing fixtures in any residential real property shall be replaced with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy, or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 4.303.1.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-type Toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 4.303.1.2 Urinals. The effective flush volume of wall mounted urinals shall not exceed 0.125 gallons per flush. The effective flush volume of all other urinals shall not exceed 0.5 gallons per flush. 4.303.1.3 Showerheads. 4.303.1.3.1 Single Showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Showerheads. 4.303.1.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to only allow one shower outlet to be in operation at a time. Note: A hand-held shower shall be considered a showerhead. 4.303.1.4 Faucets. 4.303.1.4.1 Residential Lavatory Faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.2 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. 4.303.1.4.2 Lavatory Faucets in Common and Public Use Areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. 4.303.1.4.3 Metering Faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.2 gallons per cycle. 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. Note: Where complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.1.4.5 Pre-rinse spray valves. When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Sections 1605.1 (h)(4) Table H-2, Section 1605.3 (h)(4)(A), and Section 1607 (d)(7) and shall be equipped with an integral automatic shutoff. FOR REFERENCE ONLY: The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations),Section 1605.1 (h)(4) and Section 1605.3 (h)(4)(A). Title 20 Section 1605.3 (h)(4)(A): Commercial prerinse spray values manufactured on or after January 1, 2006, shall have a minimum spray force of not less than 4.0 ounces-force (ozf)[113 grams-force(gf)] 4.303.2 Submeters for multifamily buildings and dwelling units in mixed-used residential/commercial buildings. Submeters shall be installed to measure water usage of individual rental dwelling units in accordance with the California Plumbing Code. 4.303.3 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code. TABLE - MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL)1.8 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL)MAX. 1.2 GPM @ 60 PSI MIN. 0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.2 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH 4.304 OUTDOOR WATER USE 4.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Residential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. NOTES: 1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code Regulations, Title 23, Chapter 2.7, Division 2. MWELO and supporting documents, including water budget calculator, are available at: https://www.water.ca.gov/ ABBREVIATION DEFINITIONS: HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect, Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New NOTE: THIS TABLE COMPILES THE DATA IN SECTION 4.303.1, AND IS INCLUDED AS A CONVENIENCE FOR THE USER. SECTION 4.102 DEFINITIONS 4.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) FRENCH DRAIN. A trench, hole or other depressed area loosely filled with rock, gravel, fragments of brick or similar pervious material used to collect or channel drainage or runoff water. WATTLES. Wattles are used to reduce sediment in runoff. Wattles are often constructed of natural plant materials such as hay, straw or similar material shaped in the form of tubes and placed on a downflow slope. Wattles are also used for perimeter and inlet controls. 4.106 SITE DEVELOPMENT 4.106.1 GENERAL. Preservation and use of available natural resources shall be accomplished through evaluation and careful planning to minimize negative effects on the site and adjacent areas. Preservation of slopes, management of storm water drainage and erosion controls shall comply with this section. 4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. Projects which disturb less than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre or more, shall manage storm water drainage during construction. In order to manage storm water drainage during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site. 1. Retention basins of sufficient size shall be utilized to retain storm water on the site. 2. Where storm water is conveyed to a public drainage system, collection point, gutter or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the enforcing agency. 3. Compliance with a lawfully enacted storm water management ordinance. Note: Refer to the State Water Resources Control Board for projects which disturb one acre or more of soil, or are part of a larger common plan of development which in total disturbs one acre or more of soil. (Website: https://www.waterboards.ca.gov/water_issues/programs/stormwater/construction.html) 4.106.3 GRADING AND PAVING. Construction plans shall indicate how the site grading or drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1. Swales 2. Water collection and disposal systems 3. French drains 4. Water retention gardens 5. Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. 4.106.4 Electric vehicle (EV) charging for new construction. New construction shall comply with Sections 4.106.4.1 or 4.106.4.2 to facilitate future installation and use of EV chargers. Electric vehicle supply equipment (EVSE) shall be installed in accordance with the California Electrical Code, Article 625. Exceptions: 1. On a case-by-case basis, where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon one or more of the following conditions: 1.1 Where there is no local utility power supply or the local utility is unable to supply adequate power. 1.2 Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 4.106.4, may adversely impact the construction cost of the project. 2. Accessory Dwelling Units (ADU) and Junior Accessory Dwelling Units (JADU) without additional parking facilities. 4.106.4.1 New one- and two-family dwellings and townhouses with attached private garages. For each dwelling unit, install a listed raceway to accommodate a dedicated 208/240-volt branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40-ampere 208/240-volt minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. Exemption: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the proposed location of an EV charger at the time of original construction in accordance with the California Electrical Code. 4.106.4.1.1 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE". CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. 301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area, volume, or size. The requirements shall apply only to and/or within the specific area of the addition or alteration. The mandatory provision of Section 4.106.4.2 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing multifamily buildings. See Section 4.106.4.3 for application. Note: Repairs including, but not limited to, resurfacing, restriping and repairing or maintaining existing lighting fixtures are not considered alterations for the purpose of this section. Note: On and after January 1, 2014, residential buildings undergoing permitted alterations, additions, or improvements shall replace noncompliant plumbing fixtures with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 301.2 LOW-RISE AND HIGH-RISE RESIDENTIAL BUILDINGS. [HCD] The provisions of individual sections of CALGreen may apply to either low-rise residential buildings high-rise residential buildings, or both. Individual sections will be designated by banners to indicate where the section applies specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and high-rise buildings, no banner will be used. SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy. Exceptions: 1. [HCD] Accessory structures and accessory occupancies serving residential buildings shall comply with Chapter 4 and Appendix A4, as applicable. 2. [HCD] For purposes of CALGreen, live/work units, complying with Section 419 of the California Building Code, shall not be considered mixed occupancies. Live/Work units shall comply with Chapter 4 and Appendix A4, as applicable. 4.106.4.2 New multifamily dwellings, hotels and motels and new residential parking facilities. When parking is provided, parking spaces for new multifamily dwellings, hotels and motels shall meet the requirements of Sections 4.106.4.2.1 and 4.106.4.2.2. Calculations for spaces shall be rounded up to the nearest whole number. A parking space served by electric vehicle supply equipment or designed as a future EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by a local jurisdiction. See Vehicle Code Section 22511.2 for further details. 4.106.4.2.1Multifamily development projects with less than 20 dwelling units; and hotels and motels with less than 20 sleeping units or guest rooms. The number of dwelling units, sleeping units or guest rooms shall be based on all buildings on a project site subject to this section. 1.EV Capable. Ten (10) percent of the total number of parking spaces on a building site, provided for all types of parking facilities, shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. Exceptions: 1.When EV chargers (Level 2 EVSE) are installed in a number equal to or greater than the required number of EV capable spaces. 2.When EV chargers (Level 2 EVSE) are installed in a number less than the required number of EV capable spaces, the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed. Notes: a.Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. b.There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use. 2.EV Ready. Twenty-five (25) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. For multifamily parking facilities, no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit. Exception: Areas of parking facilities served by parking lifts. 4.106.4.2.2 Multifamily development projects with 20 or more dwelling units, hotels and motels with 20 or more sleeping units or guest rooms. The number of dwelling units, sleeping units or guest rooms shall be based on all buildings on a project site subject to this section. 1.EV Capable. Ten (10) percent of the total number of parking spaces on a building site, provided for all types of parking facilities, shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. Exception: When EV chargers (Level 2 EVSE) are installed in a number greater than five (5) percent of parking spaces required by Section 4.106.4.2.2, Item 3, the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed over the five (5) percent required. Notes: a.Construction documents shall show locations of future EV spaces. b.There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use. 2.EV Ready. Twenty-five (25) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. For multifamily parking facilities, no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit. Exception: Areas of parking facilities served by parking lifts. 3.EV Chargers. Five (5) percent of the total number of parking spaces shall be equipped with Level 2 EVSE. Where common use parking is provided, at least one EV charger shall be located in the common use parking area and shall be available for use by all residents or guests. When low power Level 2 EV charging receptacles or Level 2 EVSE are installed beyond the minimum required, an automatic load management system (ALMS) may be used to reduce the maximum required electrical capacity to each space served by the ALMS. The electrical system and any on-site distribution transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each EV charging station (EVCS) served by the ALMS. The branch circuit shall have a minimum capacity of 40 amperes, and installed EVSE shall have a capacity of not less than 30 amperes. ALMS shall not be used to reduce the minimum required electrical capacity to the required EV capable spaces. 4.106.4.2.2.1 Electric vehicle charging stations (EVCS). Electric vehicle charging stations required by Section 4.106.4.2.2, Item 3, shall comply with Section 4.106.4.2.2.1. Exception: Electric vehicle charging stations serving public accommodations, public housing, motels and hotels shall not be required to comply with this section. See California Building Code, Chapter 11B, for applicable requirements. 4.106.4.2.2.1.1 Location. EVCS shall comply with at least one of the following options: 1.The charging space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space. 2.The charging space shall be located on an accessible route, as defined in the California Building Code, Chapter 2, to the building. Exception: Electric vehicle charging stations designed and constructed in compliance with the California Building Code, Chapter 11B, are not required to comply with Section 4.106.4.2.2.1.1 and Section 4.106.4.2.2.1.2, Item 3. 4.106.4.2.2.1.2 Electric vehicle charging stations (EVCS) dimensions. The charging spaces shall be designed to comply with the following: 1.The minimum length of each EV space shall be 18 feet (5486 mm). 2.The minimum width of each EV space shall be 9 feet (2743 mm). 3.One in every 25 charging spaces, but not less than one, shall also have an 8-foot (2438 mm) wide minimum aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the minimum width of the EV space is 12 feet (3658 mm). a.Surface slope for this EV space and the aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083 percent slope) in any direction. 4.106.4.2.2.1.3 Accessible EV spaces. In addition to the requirements in Sections 4.106.4.2.2.1.1 and 4.106.4.2.2.1.2, all EVSE, when installed, shall comply with the accessibility provisions for EV chargers in the California Building Code, Chapter 11B. EV ready spaces and EVCS in multifamily developments shall comply with California Building Code, Chapter 11A, Section 1109A. 4.106.4.2.3 EV space requirements. 1.Single EV space required. Install a listed raceway capable of accommodating a 208/240-volt dedicated branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or enclosure in close proximity to the location or the proposed location of the EV space. Construction documents shall identify the raceway termination point, receptacle or charger location, as applicable. The service panel and/ or subpanel shall have a 40-ampere minimum dedicated branch circuit, including branch circuit overcurrent protective device installed, or space(s) reserved to permit installation of a branch circuit overcurrent protective device. Exception: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space, at the time of original construction in accordance with the California Electrical Code. 2.Multiple EV spaces required. Construction documents shall indicate the raceway termination point and the location of installed or future EV spaces, receptacles or EV chargers. Construction documents shall also provide information on amperage of installed or future receptacles or EVSE, raceway method(s), wiring schematics and electrical load calculations. Plan design shall be based upon a 40-ampere minimum branch circuit. Required raceways and related components that are planned to be installed underground, enclosed, inaccessible or in concealed areas and spaces shall be installed at the time of original construction. SECTION 4.501 GENERAL 4.501.1 Scope The provisions of this chapter shall outline means of reducing the quality of air contaminants that are odorous, irritating and/or harmful to the comfort and well being of a building's installers, occupants and neighbors. SECTION 4.502 DEFINITIONS 5.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) AGRIFIBER PRODUCTS. Agrifiber products include wheatboard, strawboard, panel substrates and door cores, not including furniture, fixtures and equipment (FF&E) not considered base building elements. COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium density fiberboard. "Composite wood products" does not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, prefabricated wood I-joists or finger-jointed lumber, all as specified in California Code of regulations (CCR), title 17, Section 93120.1. DIRECT-VENT APPLIANCE. A fuel-burning appliance with a sealed combustion system that draws all air for combustion from the outside atmosphere and discharges all flue gases to the outside atmosphere. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AYN/AYN/AYN/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 1 (January 2023)Y = YES N/A =NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) 4.201 GENERAL 4.201.1 SCOPE. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards. DIVISION 4.2 ENERGY EFFICIENCY TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [spray force in ounce force (ozf)]MAXIMUM FLOW RATE (gpm) Product Class 1 (≤1.00 Product Class 2 (> 5.0 ozf and ≤1.20 Product Class 3 (> 8.0 ozf)1.28 Exception: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space at the time of original construction in accordance with the California Electrical Code. 4.106.4.2.4 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. 4.106.4.2.5 Electric Vehicle Ready Space Signage. Electric vehicle ready spaces shall be identified by signage or pavement markings, in compliance with Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). 4.106.4.3 Electric vehicle charging for additions and alterations of parking facilities serving existing multifamily buildings. When new parking facilities are added, or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit, ten (10) percent of the total number of parking spaces added or altered shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Notes: 1.Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. 2.There is no requirement for EV spaces to be constructed or available until EV chargers are installed for use. ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü DELTA DATE DESCRIPTION MA I N H O U S E R E M O D E L - B A T H R O O M 40 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 NE W A D U 40 1 W J o n q u i l R d , U n i t 2 , S a n t a A n a , C A 9 2 7 0 6 3/19/2025 DATE SIGNED: ARCHITECTURE MAXIMUM INCREMENTAL REACTIVITY (MIR). The maximum change in weight of ozone formed by adding a compound to the "Base Reactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to hundredths of a gram (g O³/g ROC). Note: MIR values for individual compounds and hydrocarbon solvents are specified in CCR, Title 17, Sections 94700 and 94701. MOISTURE CONTENT. The weight of the water in wood expressed in percentage of the weight of the oven-dry wood. PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted-MIR for all ingredients in a product subject to this article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging). Note: PWMIR is calculated according to equations found in CCR, Title 17, Section 94521 (a). REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential, once emitted, to contribute to ozone formation in the troposphere. VOC. A volatile organic compound (VOC) broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a). 4.503 FIREPLACES 4.503.1 GENERAL. Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. 4.504 POLLUTANT CONTROL 4.504.1 COVERING OF DUCT OPENINGS & PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. At the time of rough installation, during storage on the construction site and until final startup of the heating, cooling and ventilating equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheet metal or other methods acceptable to the enforcing agency to reduce the amount of water, dust or debris which may enter the system. 4.504.2 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with this section. 4.504.2.1 Adhesives, Sealants and Caulks. Adhesives, sealant and caulks used on the project shall meet the requirements of the following standards unless more stringent local or regional air pollution or air quality management district rules apply: 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable or SCAQMD Rule 1168 VOC limits, as shown in Table 4.504.1 or 4.504.2, as applicable. Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and tricloroethylene), except for aerosol products, as specified in Subsection 2 below. 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than 1 pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations, Title 17, commencing with section 94507. 4.504.2.2 Paints and Coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Suggested Control Measure, as shown in Table 4.504.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 4.504.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss coating, based on its gloss, as defined in subsections 4.21, 4.36, and 4.37 of the 2007 California Air Resources Board, Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in Table 4.504.3 shall apply. 4.504.2.3 Aerosol Paints and Coatings. Aerosol paints and coatings shall meet the Product-weighted MIR Limits for ROC in Section 94522(a)(2) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(e)(1) and (f)(1) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation 8, Rule 49. 4.504.2.4 Verification. Verification of compliance with this section shall be provided at the request of the enforcing agency. Documentation may include, but is not limited to, the following: 1. Manufacturer's product specification. 2. Field verification of on-site product containers. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification programs include but are not limited to the following: 1. State certified apprenticeship programs. 2. Public utility training programs. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector: 1. Certification by a national or regional green building program or standard publisher. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors. 3. Successful completion of a third party apprentice training program in the appropriate trade. 4. Other programs acceptable to the enforcing agency. Notes: 1. Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 703 VERIFICATIONS 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist. 4.505 INTERIOR MOISTURE CONTROL 4.505.1 General. Buildings shall meet or exceed the provisions of the California Building Standards Code. 4.505.2 CONCRETE SLAB FOUNDATIONS. Concrete slab foundations required to have a vapor retarder by California Building Code, Chapter 19, or concrete slab-on-ground floors required to have a vapor retarder by the California Residential Code, Chapter 5, shall also comply with this section. 4.505.2.1 Capillary break. A capillary break shall be installed in compliance with at least one of the following: 1. A 4-inch (101.6 mm) thick base of 1/2 inch (12.7mm) or larger clean aggregate shall be provided with a vapor barrier in direct contact with concrete and a concrete mix design, which will address bleeding, shrinkage, and curling, shall be used. For additional information, see American Concrete Institute, ACI 302.2R-06. 2. Other equivalent methods approved by the enforcing agency. 3. A slab design specified by a licensed design professional. 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19 percent moisture content. Moisture content shall be verified in compliance with the following: 1. Moisture content shall be determined with either a probe-type or contact-type moisture meter.Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy requirements found in Section 101.8 of this code. 2. Moisture readings shall be taken at a point 2 feet (610 mm) to 4 feet (1219 mm) from the grade stamped end of each piece verified. 3. At least three random moisture readings shall be performed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing. Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities. Wet-applied insulation products shall follow the manufacturers' drying recommendations prior to enclosure. 4.506 INDOOR AIR QUALITY AND EXHAUST 4.506.1 Bathroom exhaust fans. Each bathroom shall be mechanically ventilated and shall comply with the following: 1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. 2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidity control. a. Humidity controls shall be capable of adjustment between a relative humidity range less than or equal to 50% to a maximum of 80%. A humidity control may utilize manual or automatic means of adjustment. b. A humidity control may be a separate component to the exhaust fan and is not required to be integral (i.e., built-in) Notes: 1. For the purposes of this section, a bathroom is a room which contains a bathtub, shower or tub/shower combination. 2. Lighting integral to bathroom exhaust fans shall comply with the California Energy Code. 4.507 ENVIRONMENTAL COMFORT 4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. Heating and air conditioning systems shall be sized, designed and have their equipment selected using the following methods: 1. The heat loss and heat gain is established according to ANSI/ACCA 2 Manual J - 2011 (Residential Load Calculation), ASHRAE handbooks or other equivalent design software or methods. 2. Duct systems are sized according to ANSI/ACCA 1 Manual D - 2014 (Residential Duct Systems), ASHRAE handbooks or other equivalent design software or methods. 3. Select heating and cooling equipment according to ANSI/ACCA 3 Manual S - 2014 (Residential Equipment Selection), or other equivalent design software or methods. Exception: Use of alternate design temperatures necessary to ensure the system functions are acceptable. TABLE 4.504.1 - ADHESIVE VOC LIMIT1,2 (Less Water and Less Exempt Compounds in Grams per Liter) ARCHITECTURAL APPLICATIONS VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVE 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. TABLE 4.504.2 - SEALANT VOC LIMIT (Less Water and Less Exempt Compounds in Grams per Liter) SEALANTS VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NON-POROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 TABLE 4.504.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIF. AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIF. CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16" (8 MM). TABLE 4.504.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2,3 GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY VOC LIMIT FLAT COATINGS 50 NON-FLAT COATINGS 100 NONFLAT-HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. DIVISION 4.5 ENVIRONMENTAL QUALITY (continued) 4.504.3 CARPET SYSTEMS. All carpet installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 4.504.1. 4.504.4 RESILIENT FLOORING SYSTEMS. Where resilient flooring is installed , at least 80% of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. hhtps://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.5 COMPOSITE WOOD PRODUCTS. Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.), by or before the dates specified in those sections, as shown in Table 4.504.5 4.504.5.1 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency. Documentation shall include at least one of the following: 1. Product certifications and specifications. 2. Chain of custody certifications. 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, Section 93120, et seq.). 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, the Australian AS/NZS 2269, European 636 3S standards, and Canadian CSA 0121, CSA 0151, CSA 0153 and CSA 0325 standards. 5. Other methods acceptable to the enforcing agency. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AYN/AYN/AYN/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 2 (January 2023)Y = YES N/A =NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü DELTA DATE DESCRIPTION MA I N H O U S E R E M O D E L - B A T H R O O M 40 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 NE W A D U 40 1 W J o n q u i l R d , U n i t 2 , S a n t a A n a , C A 9 2 7 0 6 3/19/2025 DATE SIGNED: ARCHITECTURE 5 4 3 1 2 R E V I S I O N DATE BY 11122 BIXLER CIR., BUS: 714-928-2006 EMAIL: TUNGCIVIL2018@GMAIL.COM GARDEN GROVE, CA92840 FAX: 714-901-9535 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO TUNG VO, M.S., P.E. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY TUNG VO, M.S., P.E. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PDC Pr o j e c t A d d r e s s : 4 0 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 RE S I D E N T I A L P R O J E C T F O R SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 24077 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 10/31/2024 NE W A D U T24-1 TITLE 24 DETACHED ADU PLAN 3/31/233/31/25 10/18/2024 EP BATH 2 BATH 1 W/D WH BEDROOM 1 BEDROOM 2 BEDROOM 3 DINING LIVING REF. KITCHEN PANTRY -1.5"2% Min. CRH WP GFCI DW W D 30 AMP WH RF OD CT V CTV +48" GFCIAFCI +48" GFCI +30" AFCI/GFCI S CT V 240V- GFCI 240V- GFCI GFCI AFCIAFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCI +30" AFCI/GFCI +4 8 " G F C I +4 8 " G F C I +4 8 " G F C I +6 5 " G F C I 24 0 V - G F C I G F C I +4 8 " G F C I G F C I WP GFCI 24 0 V - G F C I +48" AFCI DOORBELL 1.1 TYP. 1.2 1.3 TYP. 1.4 1.6 1.6 1.6 1.8 1.7 U9 1.2 U5 U4 U8 M2M3 1.51.6 1.9 BATH 2 BATH 1 W/D WH BEDROOM 1 BEDROOM 2 BEDROOM 3 DINING LIVING REF. KITCHEN PANTRY -1.5"2% Min. D S D S S/C S D D 2DS/C P EF 59 C F M EF DVS 280 CFM 59 C F M VS VS 2D D 10 0 C F M D VS 10'-0" CLG. 10'-0" CLG. 10'-0" CLG. 10'-0" CLG. 9'-0" CLG. 9'-0" CLG. IDID ID ID V Min. 3'-0" 2.2 TYP. 2.4 2.6 2.5 2.1 2.3 2.7 2.7 2.7 GENERAL NOTES KEY NOTES DRYER MACHINE - PROVIDE GAS LINE, EXHAUST TO OUTSIDE ELECTRICAL SYMBOLS CTV FLUSH WALL MOUNTED CABLE TV RECEPTACLE FLUSH WALL MOUNTED DUPLEX RECEPTACLE FLUSH WALL MOUNTED DEDICATED DUPLEX RECEPTACLE FLUSH WALL MOUNTED HALF-SWITCHED DUPLEX RECEPTACLE GROUND FAULT CIRCUIT INTERRUPTERGFCI WATERPROOF RECEPTACLEWP EQUIPMENT LIST RF H CR DW RANGE HOOD WITH A MIN. EXHAUST RATE OF 280 CFM - VENTED TO OUTSIDE COOKING RANGE - PROVIDE GAS LINE CONNECTION DISHWASHER - PROVIDE WATER LINE REFRIGERATOR - PROVIDE WATER LINE D W WASHER MACHINE - PROVIDE DRAIN LINE WATER SHUT-OFF VALVE EP MAIN SERVICE ELECTRICAL PANEL - MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION. PROVIDE UFER GROUNDING SYSTEM PER CEC 250.52(A)(3). W/H WALL MOUNTED TANK-LESS WATER HEATER SHALL BE STRAPPED TO STRUCTURE WITH 1 1 2" x 16GA STRAPS AT TOP & BOTTOM WITH 3 8"DIA. x 3" LONG LAG BOLT - PROVIDE DRAIN LINE WATER SHUT-OFF VALVE, POWER, GAS LINE & EXHAUST TO OUTSIDE. MOUNTED @ 44" A.F.F. MIN. OUTDOOR RECEPTACLES SHALL BE LISTED AS WEATHER RESISTANT PER SECTION 406.9(B) (1). 1.1 PROVIDE A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM, PER CEC 210-52(C) (1). 1.2 PROVIDE A MINIMUM OF (2) 20-AMP SMALL APPLIANCE CIRCUITS FOR KITCHEN COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOAD SHALL BE BALANCED, PER CEC 210-52(B) (2). 1.3 FOR ELECTRIC CLOTHES DRYER READY: A DEDICATED 240 V BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE CLOTHES DRYER LOCATION AND ACCESSIBLE WITH NO OBSTRUCTION. THE THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30AMPS MIN. THE BLANK COVER SHALL BE IDENTIFIED AS "240V READY". THERE SHALL BE A RESERVED DOUBLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL LABELED "240V DRYER". 1.4 PROVIDE A MINIMUM 4" DIA. MOISTER EXHAUST DUCT TO OUTSIDE, EQUIPPED WITH BACK-DRAFT DAMPER. MOISTER EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGHT OF 14'. DUCT LENGTH IS LIMITED OR REQUIRED BY THE MANUFACTUER'S INSTALLATION INSTRUCTIONS AND APPROVED BY THE BUILDING OFFICIAL. 2.1 PROVIDE GARBAGE DISPOSAL WITH SWITCH CONTROL ON SIDE OF KITCHEN CABINET. 1.5 SWITCH FOR HALF-SWITCHED OUTLET.1.6 PROVIDE A DEDICATED GAS LINE FROM THE GAS METER TO THE WATER HEATER. 1.7 PROVIDE UFER GROUNDING SYSTEM PER CEC 250.52(A)(3). 1.8 ELECTRIC VEHICLEEV GROUNDING PANEL EXHAUST AIR TO OUTSIDE THROUGH ROOF. U9 ID INDOOR UNIT AC. CEILING MOUNTED SMOKE DETECTOR IN EACH BEDROOM & KITCHEN. INSTALL +30" FROM AIR INTAKE SMOKE DETECTOR SYSTEM SHALL DIRECT WIRED, INTERCONNECTED, SHALL BE EQUIPPED WITH A BATTERY BACKUP AND SHALL EMIT A SIGNAL WHEN THE BATTERY IS LOW. A.AMINIMUM OF 20 FT. FROM PERMENANT COOKING EQUIPMENT (OR 10 FT WITH PHOTO ELECTRIC TYPE.) B.A MINIMUM OF 3 FT. FROM BATHROOM. COMBINATION SMOKE/CARBON MONOXIDE ALARM, CEILING MOUNTED, HARD WIRED AND W/ BATTERY BACK UP.ICC APPROVED LIGHTING/MECH. SYMBOLS EF CEILING MOUNTED EXHAUST FAN/FLUORESCENT LIGHT COMBINATION. EXHAUST FAN TO EXTERIOR WITH AIRFLOW RATED ON TITLE 24. EXHAUST FAN MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE CAPABLE ADJUSTMENT BETWEEN RELATIVE HUMINITY RANGE OF 50% TO 80%. S/C S U4 NEW DUAL ELECTRICAL PANEL 200 AMP. U7 NEW GAS METER LOCATION. U5 NEW 100AMP ELECTRICAL SUB-PANEL FOR ADU. U6 NEW 100AMP ELECTRICAL SUB-PANEL FOR MAIN HOUSE. U8 SOLAR PANEL SYSTEM. 4-ZONE MULTI-SPLIT SYSTEM AC. HEAT PUMP HEATING FACILITY ON PLAN TO MATCH WITH T-24 ENERGY CALCULATION: M2 FAN COIL AND HEAT PUMP FC-12(CARRIER - 40MAHBQ12XA3) OR EQUAL FC-09(CARRIER - 40MAHBQ09XA3) OR EQUAL HP-30(CARRIER - 38MGHBQ30DA3) OR EQUAL MECHANICAL: HP30 FC-12 (LIVING) FC-09 (BEDROOM 1) FC-09 (BEDROOM 2) FC-09 (BEDROOM 3) HEAT PUMP WATER HEATERS - T24: Rheem PRO H40 T2 RH310BM (40 gal, JA13) OR EQUAL 2.2 PROVIDE ACCESS DOOR . OPENING SHALL BE 30" x 30" WITH 30" MIN. HEADROOM. ACCESS DOOR MUST BE WITHIN 20 FEET OF FURNACE UNIT AND SHOULD HAVE A CONTINUOUS SOLID PATHWAY 24" MIN. WIDE. PROVIDE A SWITCH CONTROLLED LIGHT. [CMC. 304.4.1] M3 PAD SUPPORTING CONDENSER SHALL BE A MINIMUM OF 3" ABOVE THE GRADE (1105.2 CMC) 2.6 FAU LOCATED IN ATTIC WITH VERTICAL DUCT VENT TO EXTERIOR. PROVIDE POWER CONNECTION . PROVIDE MINIMUM 36"x36" CLEAR WORKING SPACE PLATFORM IN FRONT OF UNIT. D / VS LIGHT SWITCH. ALL SWITCHES TO HAVE DIMMER CONTROL, EXCEPT, UTILITY & LAUNDRY RM, GARAGE D INDICATE DIMMER OS INDICATE OCCUPANCY SENSOR VS INDICATE VACANCY SENSOR P INDICATE PHOTOCELL SENSOR RECESSED LED DOWN LIGHT FIXTURE WALL MOUNTED EXTERIOR LED LIGHT FIXTURE, HIGH EFFICACY AND CONTROL BY MOTION SENSOR AND PHOTO-SENSOR COMBINATIONS. WALL MOUNTED BATHROOM LED LIGHT FIXTURE 1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2.ALL ELECTRICAL OUTLET TO BE MOUNTED @ 15" A.F.F. 3.ALL APPLIANCES TO BE "ENERGY STAR". 4.PROVIDE TAMPER-RESISTANT FOR ALL 15 & 20 AMP RECEPTACLES IN NEW CONSTRUCTION AREA PER CEC 406.12. 5.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM VENTED TO OUTDOOR WITH RATE = 100 CFM. 6. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: A. ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED-UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS; OR B. A DEDICATED RACEWAY FROM THE MAIN SERVICE TO A PANELBOARD (SUBPANEL) THAT SUPPLIES THE BRANCH CIRCUITS IN SEC. 150.0(S)(2). ALL BRANCH CIRCUITS ARE PERMITTED TO BE SUPPLIED BY THE MAIN SERVICE PANEL PRIOR TO THE INSTALLATION OF AN ESS. THE TRADE SIZE OF THE RACEWAY SHALL BE NOT LESS THAN 1 INCH. THE PANELBOARD THAT SUPPLIES THE BRANCH CIRCUITS (SUBPANEL) MUST BE LABELED “SUBPANEL SHALL INCLUDE ALL BACKED-UP LOAD CIRCUITS.” 7.A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED AND HAVE THEIR SOURCE OF SUPPLY COLLOCATED AT A SINGLE PANELBOARD SUITABLE TO BE SUPPLIED BY THE ESS. AT LEAST ONE CIRCUIT SHALL SUPPLY THE REFRIGERATOR, ONE LIGHTING CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS AND AT LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM RECEPTACLE OUTLET. 8.THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPS. 9.SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/ TRANSFER SWITCH WITHIN 3 FT. OF THE MAIN PANELBOARD. RACEWAYS SHALL BE INSTALLED BETWEEN THE PANELBOARD AND THE SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH LOCATION TO ALLOW THE CONNECTION OF BACKUP POWER SOURCE. 10.ALL INSTALLED LUMINARIES MUST BE HIGH EFFICACY IN ACCORDANCE WITH TABLE 150.0-A. 11.EXHAUST FANS MUST BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMS. 12.IN BATHROOMS, GARAGE, LAUNDRY ROOM, UTILITY ROOM, AT LEAST ONE LUMINARIES IN EACH OF THESE SPACES MUST BE CONTROLLED BY VACANCY SENSOR. 13.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO BUILDING MUST MEET THE REQUIREMENT IN ITEM 150.0(k)3Ai (ON AND OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM 150.0(k)3Aii (PHOTOCELL AND MOTION SENSOR) OR ITEM 150.0(k)3Aiii (PHOTO CONTROL AND AUTOMATIC TIME SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS). 14.SHOW COMPLIANCE WITH THE FOLLOWING LIGHTING MEASURES: [150.0(K) / 160.5(A)] A.KITCHENS. ALL INSTALLED WATTAGE OF LUMINARIES IN KITCHENS SHALL BE HIGH EFFICACY. B.LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS, WALK-IN CLOSETS AND UTILITY ROOMS. ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY AN OCCUPANCY OR VACANCY SENSOR. C.HABITABLE SPACES. ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY A VACANCY/ OCCUPANCY SENSOR OR DIMMER. D.OUTDOOR LIGHTING. ALL LUMINAIRES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINAIRES AND SHALL BE CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR COMBINATION (WITH OVERRIDE). SEE 150(K)3 FOR REQUIREMENTS. 2.4 EXHAUST FAN MUST BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMS. AND SHOULD BE HUMIDISTAT FAN. 2.5 SMOKE ALARMS WITHIN 20 FEET OF COOK TOP SHALL BE IONIZED OR PHOTOELECTRIC TYPE. 2.3 PROVIDE KITCHEN LOCAL EXHAUST SYSTEM VENTED TO OUTDOOR WITH RATE = 280 CFM . 2.7 PROVIDE LIGHTING WITH CONTROLLED BY VACANCY SENSOR IN BATHROOM, W.I. CLOSET, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS. 2.7 PROVIDE LIGHTING WITH CONTROLLED BY VACANCY SENSOR IN BATHROOM, W.I. CLOSET, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS. 1.9 FOR ELECTRIC COOKTOP: A DEDICATED 240 V BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE COOKTOP LOCATION AND ACCESSIBLE WITH NO OBSTRUCTION. THE THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30AMPS MIN. THE BLANK COVER SHALL BE INDENTIFIED AS "240V READY". THERE SHALL BE A RESERVED DOUBLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL LABELED "240V COOKTOP". DELTA DATE DESCRIPTION MA I N H O U S E R E M O D E L - B A T H R O O M 40 1 W J o n q u i l R d , S a n t a A n a , C A 9 2 7 0 6 NE W A D U 40 1 W J o n q u i l R d , U n i t 2 , S a n t a A n a , C A 9 2 7 0 6 3/19/2025 DATE SIGNED: ARCHITECTURE 1 PROPOSED ADU - ELECTRICAL & EQUIPMENT 1/4"=1'-0" 2 PROPOSED ADU - REFLECTED CEILING PLAN 1/4"=1'-0" SphSA `*V H00-�`S� Certificate of Compliance Payment of School Facility Fees Santa Ana Unified School District CITY OF SANTA ANA Planning and Building Agency 5126 Approved FOR PERMIT ISSUANCE Name (Firs MI, Last) -Telephone Master ID: �� �.. A Project Address Tract/Parcel Number C( State, Zip Code \ � ' Jt'\1Y l J� 1 ' Name (First, MI, Last) I Telephone Use of Building (check) Type of Project (check) Residential Commercial ❑ Senior Housing ❑ Ne\(V Addition ❑ Alteration ❑ Description of Project Number of Square Feet of 1 Residential Space ` Sq.Ft x $ Total S l� (Dev. Fee) Number of Square Feet of Commercial Space Sq.Ft x $ (Dev. Fee) Total $ The above representations as to square footage are true. Applicant agrees that if it is later determined that such representations are not true, then this certificate shall automatically terminate, and the appropriate City/County shall be notified. Applicant is hereby noticed that any party filing a protest regarding the imposition of fees pursuant to Govejnmr,nt Code Section 53080 must do so within 90 days from the payment of the fee. Applicant Name (Please Print) Date Signature This certifies that the above -named Applicant has paid school facility fees in compliance with all existing and applicable sections of the Government Code and Education Code. DA� ( �M'k oy- P I (A V1 rV_11 -j ZS Sant na Unified School District Authorized Representative ate DISTRIBUTION While - Cily/Counry Canary - Applicant Pink - Facilities SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall August 18, 2024 Also sent via email to: knguyen@adkbancorpinc.com Tien Nguyen 14615 Magnolia Street Westminster, CA 92683 Subject: Address Assignment for a Detached Accessory Dwelling Unit located at 401 West Jonquil Road (APN: 002-037-32) in Santa Ana, CA Dear Tien, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a 981-square-foot detached ADU located at 401 West Jonquil Road (APN: 002-037-32). Notice is hereby given that the following assigned address shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address to be Activated/Posted To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. The address will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 664-2753 or by email at PRaj@santa-ana.org. Sincerely, Punkaj Raj Planning Technician Exhibit A – Address Plan Address Letter for 401 West Jonquil Road Page 2 of 2 c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Mishele Richards, Orange County Fire Authority, GEO Files Coordinator Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager  (E) GARAGE (E) SINGLE FAMILY DWELLING 401 W JONQUIL ROAD (N) ADU401 W JONQUIL ROADUNIT 2 EXHIBIT A: ADDRESS PLAN O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 401 W Jonquil Rd, Santa Ana, CA 92706 2 1,690 Sq.ft.981 Sq.ft 2,671 SF 1 0 92706 Page 1 of 1 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2022 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 Rigid Conduit Service Entrance Conductor Riser Underground Service Lateral METER Rev. 1/21/2020 GEOTECHNICAL INTERNATIONAL LAN & ASSOCIATES Land Survey & Civil, Structural & Geotechnical Engineering 13139 Harbor Boulevard, Garden Grove, CA 92843 Tel: (714) 414-9215, Fax: (714) 537 – 7974, Email: Lanpham9@hotmail.com Project No. SA-02-09-24 October 18, 2024 Darren Dien Tran ADK BANCORP INC. 714-791-2536 DNGUYEN@ADKBANCORPINC.COM SUBJECT: Soil Report for Proposed New Detached ADU, 401 W. Jonquil Road, Santa Ana, CA 92706. Dear Mr. Tran: In accordance with the requirements of the City and per your request and authorization, this soil report has been prepared for the proposed project. It is noted that Geotechnical International was the project geotechnical consultant of many similar projects in the City of Santa Ana. Therefore, we are familiar with the geotechnical conditions of the site. Follow is a summary of our findings and conclusions and recommendations for this project. Site Description and Proposed Development The subject property is located at the northeasterly corner of Jonquil Road & Park Lane, adjacent to and on the west side of Santa Ana Freeway, west of Broadway, east of Flower Street, north of Santiago Creek (north of Riverside Drive), and south of Mercury Lane, within a developed residential area. A one-story house with a detached garage exists at the site. Based on the Site Plan prepared by the designer, we understand that the proposed new detached ADU will be constructed in the rear yard area where is currently covering with grass. Note to the geotechnical report reviewer: Please see the actual full-scale plans prepared by the architect/designer/civil engineer which are separately submitted to the City for review, for clarification/details of the proposed development, as needed. Unit #2, Santa Ana, CA 92706. Page 2 The site is relatively flat; and we understand that additional grading / raw cut/raw fill is not proposed for the site. Geotechnical Conditions The subject site is a previously graded lot where a house exists. The on-site soils were previously properly treated, as necessary, and evaluated to be suitable for structural support prior to approval for construction of the existing house. Distress to the existing house due to settlement and/or any other geotechnical issues was not observed / reported. Therefore, deep-seated settlement of the soils underlying the site is not considered to be a concern for the proposed addition of an ADU onto the subject approved lot. Based on the State of California SEISMIC HAZARD ZONES Map, Orange Quadrangle, the subject site is located within a potential liquefaction zone. For conservative purposes, we assume that the site will be subjected to the liquefaction; and to mitigate the potential adverse effects due to potential liquefaction, as for other recent near-by projects, a strengthened/stiffened foundation system [in accordance with the Special Publication 117A (SP117A), “Guidelines for Evaluating And Mitigating Seismic Hazards in California” dated 2008, published by California Geotechnical Survey (CGS), page 60] is recommended to be used for the proposed new structure. To verify the near ground surface soils, a 5 ft. deep test hole has been drilled using a hand-held drilling tool and soil samples were collected for laboratory testing. The approximate location of the test hole is depicted on the Site Plan / Geotechnical Map. The geotechnical boring log and summary of results of the laboratory testing are included in Appendix B. Based on the data of our test hole, the near ground surface earth materials generally consisted of silty fine sand with minor clay, damp to moist, medium dense and have a very low expansion potential. It is noted that, based on the State of California SEISMIC HAZARD ZONES Map, Orange Quadrangle, the subject site is located within a potential liquefaction zone. For conservative purposes, (instead of performing a conventional site-specific geotechnical including drilling a 50 ft deep test hole with soil sampling, laboratory testing and engineering calculations / analysis to verify whether the site is subject to liquefaction or not), we assume that the site will be subjected to the liquefaction; and to mitigate the potential adverse effects due to potential liquefaction, as for other near-by projects, a strengthened/stiffened foundation system [as mentioned in the Special Publication 117A (SP117A), “Guidelines for Evaluating And Mitigating Seismic Hazards in California” dated 2008, published by California Geotechnical Survey (CGS), page 60] is recommended to be used for the proposed new structure. Groundwater Page 3 Free standing groundwater was not encountered in our test hole. Free standing ground water was not reported to be an issue at the site and in the vicinity. Based on the “Historically Highest Ground Water Contours and Borehole Log Data Locations, Orange Quadrangle”, Plate 1.2 of the Open-File Report 97-19 prepared by California Division of Mines and Geology (CDMG), Department of Conservation, the historically highest groundwater level at the subject site is about 30 ft. below the ground surface. Deep footings/excavations are not proposed for the site; therefore adverse effects due to groundwater are not anticipated for the proposed development. Note: it is not anticipated; however, if wet soils are encountered, removal of the wet soils and replacement with drier soils/cement slurry can be performed. In addition, if needed, crushed rock and or geogrids for bridging, etc. can also be used. This will be determined by the geotechnical consultant based on the exposed conditions during the excavations at the site. Seismicity The subject site is located in Southern California, which is a major earthquake-prone zone. Therefore, the owner(s) of this property should be aware of the seismic risks associated with being located in this zone. The Soil Site Class D Default can be used for the soils underlying the subject site. The Seismic Design Category D can be used for the site. The following seismic parameters obtained from the computer program https:// seismicmaps.org prepared by SEAOC [Structural Engineers Association Of California] in conjunction with California’s Office of Statewide Health Planning and Development [OSHPD] ) in accordance with ASCE7-16 can be used for the site. • Fa = 1.2 • Fv = null* • Mapped Spectral Accelerations Values: Ss = 1.335 (for the short period of 0.2 second) S1 = 0.475 (for the 1-second period) • Maximum Considered Earthquake Spectral Response Accelerations: SMs = FaSs = 1.602 (for the short period of 0.2 second) Page 4 SM1 = FvS1 = null* (for the 1-second period) • Design Spectral Response Accelerations: SDs = 2/3 SMs = 1.068 (for the short period of 0.2 second) SD1 = 2/3 SM1 = null* (for the 1-second period) • PGA = 0.562 Please see ASCE 7-16, Section 11.4.8. Please see APPENDIX C for additional seismic parameters, as needed. Note: In general, the structural consultant of record for this project should review the seismic parameters provided in this report and the 2022 CBC to evaluate the seismic design. Final selection of design coefficients should be made by the structural consultant based on the local laws and ordinances, expected structure response, and the desired level of conservatism. The civil/structural design engineer should consult with the project geotechnical consultant, if additional geotechnical information is needed for structural seismic design. Faults No active faults are known to exist within or near the site. The probability of primary surface rupture or deformation at the site is, therefore, considered very low. The site is not designated to be located within the Special Studies/Earthquake Zone under the Alquist-Priolo Special Studies Act. Liquefaction Potential As previously mentioned, for conservative purposes, the subject site is assumed to be subject to the liquefaction. Therefore, the owner(s) of this property should be aware of the risks associated with the potential liquefaction such as structural distress due to the potential differential settlement caused by the potential liquefaction. As previously mentioned, for conservative purposes, a strengthened / stiffened foundation system (having thicker slabs with more reinforcements and deeper and wider footings with more reinforcement as recommended in this report) should be used for support of the proposed structure. Potential Consequences of Liquefaction or Secondary Liquefaction Included Hazards Potential consequences of liquefaction or secondary liquefaction included hazards generally consist of differential settlement (vertical deformations), lateral Page 5 movement/lateral spreading (horizontal deformations), oscillation, and reduction in foundation soil-bearing capacity (bearing failure). A sloping condition or drainage or stream channel does not exist at the site; therefore, lateral movement/lateral spreading, oscillation, etc. due to potential liquefaction are not anticipated to be credible hazards for the proposed new structure. We believe if the area would be “liquefied” in the future due to a very strong earthquake, the potential damage to the proposed new structures which will be properly structurally designed in accordance with the new up-to-date codes would be much less severe than the existing on-site structures and surrounding existing houses which have been previously structurally designed based on old codes (which are much less stringent than the current new codes). However, the owner(s) of this property should be aware of the potential damage to the new structures due to liquefaction. In summary, it should be recognized that structural mitigation may not reduce the potential of the soils to liquefy during an earthquake; and there will remain some risk that the new structures could still suffer damage if liquefaction occurs, during a very strong earthquake. For conservative purposes, a strengthened / stiffened foundation system as recommended in this report should be used for support of the proposed structure. Slope Stability The site is a flat area; therefore, slope instability is not a concern for the proposed development. CONCLUSIONS AND RECOMMENDATIONS General Conclusions Construction of the proposed structure at the subject site is considered geotechnically feasible, provided the recommendations outlined in this report are implemented. Note: The conclusions and recommendations of this report are based on information as interpreted from our limited subsurface investigation. It is not anticipated but they should be revised accordingly if geotechnical conditions to be exposed during site preparation/ grading and construction significantly differ from our findings and interpretations. In general, a conventional shallow foundation can be used for support of the proposed structure. The following recommendations are considered minimum and may be superseded by more restrictive requirements of the architect, civil/structural engineer, building codes, or governing agencies. Page 6 Geotechnical Impact on Neighboring Properties Adverse geotechnical impact of the proposed development on the neighboring properties is not anticipated, provided the recommendations outlined in this report are properly implemented. Site Preparation/Grading To create a relatively uniform new engineered compacted fill layer for a proposed new structural slab-on-grade area, over-excavation and recompaction of about 3 ft. deep (measured from the existing ground surface) of the existing on-site soils should be performed. The lateral limits of the over-excavation should be minimum equal to depth of removal (3 ft. in this case) beyond the outside perimeter of the proposed new structure. For the proposed new exterior concrete slabs including new driveway, if any, the over excavation and recompaction should be minimum 1 ft deep and 1 ft. outside of the new slab areas. Deeper remedial removal is not anticipated; however, this will be determined in the field by the project geotechnical engineer, based on the actual conditions to be exposed at the time of the site grading/preparation. The fill/backfill materials, if any, should be free of organic matter and oversized materials, 4 inches or greater in diameter, placed in near-horizontal loose lifts not to exceed eight inches in thickness, and moisture conditioned to slightly over optimum moisture content prior to compaction. Imported soils, if any, should have a very low expansion potential and should be geotechnically observed/tested and accepted by the geotechnical consultant prior to using at the site. In general, grading at the site, if any, should be performed in accordance with the requirements of the City and under the geotechnical observation and testing of the project geotechnical consultant. The compaction criterion for fill and backfill materials is a minimum of 90% of the maximum density determined in accordance with ASTM Test Method D1557. Temporary Excavations In general, temporary excavations should be performed in accordance with OSHA requirements. In general, care should be taken during excavation near an existing structural object, if any to ensure no damage is done to the existing object. Page 7 For this project, the proposed detached ADU will be located far away from the existing building. Therefore, temporary excavation for this project does not impact the existing footings. BUILDING FOUNDATION DESIGN GUIDELINES Geotechnical Parameters For Structural Design For conservative purposes, the following “lowest” code values should be used for structural design, as needed. a. Allowable vertical bearing earth pressure: 1,500 psf. An increase of one-third is permitted when using the alternative load combinations that include wind or earthquake loads. b. Lateral bearing passive earth pressure: 100 psf. per foot into competent materials below the finished ground surface. An increase of one third is permitted when using the alternative load combinations that include wind or earthquake loads. c. Lateral Sliding Resistance: cohesion = 130 psf. The cohesion value is to be multiplied by the contact area. In no case shall the lateral sliding resistance exceed one-half the dead load. d. Soil unit weight: 120 pcf. New Building Footings In general, the foundation system for the proposed structure must be properly designed by the civil/structural design engineer of record for this project and reviewed and approved by the city prior to construction. New building footings should be embedded minimum 24-inches below the adjacent lowest finished grade. Minimum widths for isolated columns/pad footings, if any, should be 24-inches, and for continuous wall footings should be 15-inches for one-story and 18- inches for two story portions, if any. Minimum reinforcement for new continuous footings should be two #5 re-bars at top and two #5 re-bars at bottom. Settlement Page 8 Distress to the existing house due to settlement of the underlying soils was not observed / reported. Therefore, deep-seated settlement of the soils underlying the site is not considered to be a concern for the proposed development. In general, based on our experience, the conventional total settlement of ½ inch and a differential settlement of ¼ inch over a horizontal distance of 30 feet are anticipated for the proposed new structure and would occur during the construction stage. New (Interior) Building Slabs-on-Grade New (interior) building slabs-on-grade should be minimum 5 inches thick, reinforced with #4 re-bars at 12 inches on centers, or equivalent, placed at mid-height of the slab. New slabs should be underlain by a 2-inch thick layer of clean sand. For moisture sensitive floor areas, the new slabs should be underlain by a 10-mil polyethylene moisture barrier membrane (such as Visqueen). The moisture barrier membrane should be properly lapped and sealed at joints and around any breaks such as openings for utility conduits. Note: CAL Green Code, and/or other applicable codes/City’s requirements should govern and be followed. The entire slab-on-grade system including the capillary break / vapor/moisture retarder should be properly designed by the project civil /structural design engineer of record (but not by the geotechnical engineer) and reviewed and approved by the City prior to construction. New Exterior Slabs-on-Grade To reduce the potential for excessive cracking, new exterior concrete slabs-on-grade, if any, should be minimum 4 inches thick, provided with construction or weakened plane joints at frequent intervals (e. g., every 6 feet or less). Provision of a 2-inch thick layer of crushed rock, gravel, or clean sand to be placed beneath the slabs and/or reinforcement, such as #3 re-bars at 24 inches on-centers, or equivalent, placed at the mid-height of the slab should be considered. The subgrade soils for the exterior slabs should be properly re- compacted. Slab Subgrade Pre-Saturation The conventional pre-saturation of subgrade soils to minimum 140% of the optimum moisture content to minimum 24 inches deep is not considered necessary for this project. However, spraying with water should be performed prior to concrete pour. Other Recommendations for Reducing Slab Cracking While not a geotechnical issue, the potential for slab cracking may also be reduced by careful control of water/cement ratio and slump of concrete. The contractor should take Page 9 appropriate curing precautions during the pouring of concrete in hot weather to reduce cracking of slabs. A slip sheet (or equivalent) can be utilized if grouted tile, marble tile, or other crack- sensitive floor covering is planned directly on concrete slabs. New Driveway The minimum section required by the City can be used for a new driveway, if any. If there is no minimum requirements by the City, a 5-inch thick concrete slab (PCC), reinforced with #4 rebar (placed at mid-height of slabs) at 18 inches on-centers both ways, or 5-in. thick asphalt concrete (AC), or equivalent, over a 6-inch thick layer of aggregate base (AB) can be used. The aggregate base and subgrade should be properly compacted to a minimum of 95% and 90%, respectively, of the maximum density determined in accordance with ASTM D1557 prior to placement of the concrete slab. Spraying the compacted subgrade soils with water should be performed prior to concrete pour. If pavers are to be used, they must be properly designed by the civil engineer of record for this project and approved by the city prior to construction. Additional geotechnical data can be provided for design, if requested. Site Drainage In general, proper surface drainage should be checked, improved as needed, and maintained to ensure surface water flows away from all structures. Requirements by the city and applicable CBC (2022 CBC) should also be followed. Roof gutters should be properly provided. Roof drains, gutters and downspouts should be maintained to function as intended. Outlet drains should be kept open. Irrigation at the site, if any, should be kept to a minimum required to support plant life. In the future, sources of uncontrolled water, such as leaky sewer, water (domestic, irrigation) or drainpipe, should be repaired if identified. Seismic Design We recommend the proposed new structure be structurally designed to meet the applicable building codes and requirements of the controlling governmental agencies. The seismic parameters provided in the “Seismicity” section of this report can be used. The civil/structural design engineer should consult with the project geotechnical consultant, if additional geotechnical information is needed for the seismic design. Cement Type For Concrete in Contact with On-Site Earth Materials Page 10 Our previous tests performed on the soils of many lots in the City of Santa Ana which are similar to the on-site soils show negligible water-soluble sulfate contents. Sulfate attack on concrete was not observed for the existing on-site house and other houses in the surrounding areas. It appears sulfate attack on concrete is not considered to be a problem for this project. However, for conservative purpose, Type V cement with a maximum water/cement ratio of 0.45 and a minimum concrete strength, f'c of 4,500 psi is recommended to be used for concrete in contact with the on-site soils. Additional water- soluble sulfate content testing can be performed for the soils at the site, as needed. The test can be conducted during and/or after completion of site preparation/grading. The applicable California Building Code (2022 CBC) and other requirements by controlling governmental agencies should be followed. Corrosion To Ferrous Metals and Copper For conservative purposes, the on-site soils can be considered severely corrosive to ferrous metals and copper. Underground/buried ferrous metals or copper are not planned to be used for this project. However, if underground/buried ferrous metals or copper are planned to be used at the site, they should be properly protected. A corrosion specialist can be consulted. Testing can be performed for verification of the potential corrosion of the soils at the site to ferrous metals and copper, if needed. The test can be performed during and/or after completion of grading. Geotechnical Review of Grading and Foundation Plans Based on the City’s requirements, the project geotechnical consultant should review, “approve” and sign the project grading and foundation plans with details/specifications, if any, indicating conformation to applicable geotechnical recommendations. We will corporate with the civil/structural design engineers who prepare the plans to ensure our geotechnical recommendations are properly incorporated into the plans. Geotechnical Observation and Testing During Construction We recommend that a qualified geotechnical consultant be retained to provide geotechnical engineering services, including geotechnical observation/testing, during the construction phase of the project. This is to verify the compliance with the design, specifications and/or recommendations, and to allow design changes in the event that subsurface conditions differ from those anticipated. Geotechnical observation/testing can be performed at the following stages:  During ANY grading operations, including excavation, removal, filling and backfilling, etc.  During and after excavation for footings to verify the adequacy of underlying materials. Page 11  After pre-saturation of slab subgrade earth materials, if any, prior to pouring concrete.  After compaction of subgrade soils and/or aggregate base for exterior slabs and or driveway, if any.  During backfill of drainage and utility line trenches, if any, to verify proper compaction.  When/If any unusual geotechnical conditions are encountered. Note: If Geotechnical International is not provided the opportunity to perform the geotechnical observation/testing during the construction phase, Geotechnical International will take no responsibility for the conclusions and recommendations contained in our report in the event that subsurface conditions differ from those interpreted and anticipated during our preliminary investigation phase prior to the start of construction. Page 12 CLOSURE The conclusion and recommendations contained in this report are presented based on geotechnical data as described herein which are believed representative of the total project area. However, earth materials can vary in characteristics, both laterally and vertically, and those variations could affect the conclusions and recommendations contained herein. As such, observation and testing by a qualified geotechnical consultant during the construction phase of the project are essential to confirming the basis of this report. This report has been prepared consistent with that level of care being provided by other professionals providing similar services at the locale and time period. The contents of this report are professional opinions and as such, are not to be considered a guaranty or warranty. This report should be reviewed and updated after a period of one year or if the lot ownership or site conditions / proposed development change from that described herein. The following are attached and complete our report: Appendix A – References Appendix B – Geotechnical Log of Test Hole and Laboratory Test Results Appendix C – Seismic Data Figure 1 – Vicinity Map Figure 2 – Site Plan/Geotechnical Map If you have any questions or require clarification, please contact this office. This opportunity to be of service is sincerely appreciated. Very truly yours, Lan N. Pham, P.E. Chief Geotechnical Engineer RGE686, Exp. 3/31/25 Page 13 APPENDIX A REFERENCES Page 14 REFERENCES 1. California Division of Mines and Geology (CDMG), the Resources Agency, Dept. of Conservation, 1981, “Geology Map of Orange County Showing Mines and Mineral Deposits”, scale 1:48,000, 1” = 4000’, or 1” = 0.76 miles, prepared in corporation with County of Orange EMA, compiled by P.K. Morton and R.V. Miller, dated 1981. 2. California Division of Mines and Geology (CDMG), Department of Conservation, 1997, 1998, “Seismic Hazard Zones, Orange Quadrangle”, Scale 1:24,000 (1” = 2,000 ft or 1” = 0.38 miles), Liquefaction Zone Released April 07, 1997, Landslide Released: April 15, 1998. 3. California Division of Mines and Geology, 1997, “Seismic Hazard Zone Report for The Orange 7.5-minute Quadrangle, Orange County, California,” Seismic Hazard Zone Report 011,” revised 2006. Page 15 APPENDIX B GEOTECHNICAL LOG OF TEST HOLE AND LABORATORY TEST RESULTS Page 16 GEOTECHNICAL LOG OF TEST HOLE Date: September 19, 2024 TEST HOLE No. 1 Project No. Darren Tran Job No.: SA-02-09-24 Hole Diameter: 4 + inches Equipment: Hand-Auger DEPTH DESCRIPTION 0’ - 1’+ (Grass). Medium grey silty fine sand with minor clay, damp to moist, medium dense. 1’ - 4’+ Light brown silty fine sand with some clay, moist, medium dense. 4’- end Medium brown clayey silty fine sand, moist, medium dense/stiff. Total Depth: 5 ft. + No Caving No Free-Standing Groundwater Hole backfilled with onsite soils Page 17 EXPANSION INDEX TEST RESULTS Sample Compacted Moisture Content Expansion Expansion Location Dry Compacted Final Index Potential Density (pcf) (%) (%) Classification TH-1 @ 0’ – 3’ 107.5 10.5 20.7 zero very low Test Method: ASTM D4829 Page 18 ATTERBERG LIMITS TEST RESULTS Sample Location Liquid Limit Plastic Limit Plasticity Index TH-1 @ 0’ - 3’ 41 30 11 Test Method: ASTM D4318 Page 19 APPENDIX C SEISMIC DATA USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error. USGS web services are now operational so this tool should work as expected. 401 W Jonquil Rd, Santa Ana, CA 92706, USA Latitude, Longitude: 33.7721242, -117.8716092 Date 10/2/2024, 11:05:59 PM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.335 MCER ground motion. (for 0.2 second period) S1 0.475 MCER ground motion. (for 1.0s period) SMS 1.602 Site-modified spectral acceleration value SM1 null -See Section 11.4.8 Site-modified spectral acceleration value SDS 1.068 Numeric seismic design value at 0.2 second SA SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.562 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.675 Site modified peak ground acceleration TL 8 Long-period transition period in seconds SsRT 1.335 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.438 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.61 Factored deterministic acceleration value. (0.2 second) S1RT 0.475 Probabilistic risk-targeted ground motion. (1.0 second) S1UH 0.514 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. S1D 0.6 Factored deterministic acceleration value. (1.0 second) PGAd 0.665 Factored deterministic acceleration value. (Peak Ground Acceleration) PGAUH 0.562 Uniform-hazard (2% probability of exceedance in 50 years) Peak Ground Acceleration CRS 0.928 Mapped value of the risk coefficient at short periods CR1 0.925 Mapped value of the risk coefficient at a period of 1 s CV 1.367 Vertical coefficient 10/2/24, 11:35 PM U.S. Seismic Design Maps https://www.seismicmaps.org 1/2 DISCLAIMER While the information presented on this website is believed to be correct, SEAOC /OSHPD and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC / OSHPD do not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the seismic data provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the search results of this website. 10/2/24, 11:35 PM U.S. Seismic Design Maps https://www.seismicmaps.org 2/2 VICINITY MAP FIGURE 1 401 W. JONQUIL ROAD SANTA ANA, CA 92706 SITE 401 W. JONQUIL ROAD SANTA ANA, CA 92706 SITE PLAN/GEOTECHNICAL MAP FIGURE 2 TH E E N T I R E S I T E I S U N D E R L A I N B Y A L L U V I U M A N D C O L L U V I U M REDUCED SCALE Approximate Location of Test Hole TH-1 TUNG THANH VO, M.S., P.E. 11122 BIXLER CIR GARDEN GROVE CA 92840 BUS: 714-928-2006 FAX: 714-901-9535 EMAIL: tungcivil2018@gmail.com STRUCTURAL ANALYSIS ********************** SUBMITAL FOR BUILDING DEPARTMENT CLIENT : NEW ADU. PROJECT NAME : NEW ADU. LOCATION : 401 W JONQUIL RD, UNIT #2, SANTA ANA, CALIFORNIA, 92706. JOB NUMBER : 24077. 1st SUBMITAL: October 31, 2024 VERTICAL, LATERAL DESIGNED BY: TUNG VO, M.S., P.E. DESIGN CRITERIA SHEET Job# 24077 CODE: 2022 CALIFORNIA BUILDING CODE In all cases calculations will supersede this design criteria sheet. TIMBER Douglas fir-larch-19% max. moisture content. 4X Members: No .2 or Better 6X,8X Beams and Headers: No.1 or Better 2X Joists and Rafters: No. 2 or Better Plates and Blocking: Standard Grade or Better Studs: Stud Grade or Better Mud Sills: Pressure Treated Utility Grade or Better CONCRETE 1.Drypack shall be composed of one part Portland cement to not more than three-part sand. 2.All structural concrete…………………………. f’c=2500 psi w/inspection. All slab-on –grate/continuous footing /pads……… f’c=2500 psi w/inspection. All concrete shall reach minimum compressive strength at 28 days. REINFORCING STEEL 1. All reinforcing shall be A.S.T.M.A-615-40 for #4 bars and smaller, A-615-60 for #5 bars and larger. Welded wire fabric to be A.S.T.M. A-185, lab 1-1/2 spaces ,9” min. 2. Development length of Tension Bars shall be calculated per ACI318-19 Section 12.2.2. Class B splice =1.3xld. Splice lengths for 2500 psi concrete is: # 4 Bars (40k) =21”, #5 Bars (60k) =39”, #6 Bars (60k) =47” (30 dia. for compression). Masonry reinforcement shall have lappings of 48dia.or 2’-0”. This is in all cases U.N.O. 3. All reinforcing bars shall be accurately and securely placed before pouring concrete, or grouting masonry. 4. Concrete protection for reinforcement shall be at least equal to the diameter of the bars. Cover for cast-in-place concrete shall be as follows, U.N.O: A. Concrete cast against & permanently exposed to earth…………………3” B. Concrete exposed to earth or weather <= #5 Bar ………………………1 ½” #6#18 bars 2” C. Concrete not exposed to weather or in contact with ground Slab, wall, joist, <= #11bars …………………………………………… 3/4” Beams & Columns: Primary reinforcement, ties, stirrups, spirals………….1 ½” STRUCTURAL STEEL 1. Fabrication and erection of structural steel shall be in accordance with “specification for the Design, Fabrication and Erection of Structural Steel Buildings “, AISC, current edition. Steel to conform to ASTM A992.Round pipe columns shall conform to ASTM A35, Grade B.Square /Rectangular Steel tubes ASTM A500,Grade B . 2. All welding shall be performed by certified welders, using the Electric Shielded Arc Process at licensed shops or otherwise approved by the Bldg. Dept. Continuous inspection required for all field welding. 3. All steel exposed to weather shall be hot –dip galvanized after fabrication, or other approved weatherproofing method 4. Where finish is attached to structure steel, provide ½” f both holes @ 4’-0” O.C. for attachment of nailers, U.N.O. see architectural drawings for finishes (nelson studs ½”x3” CPL may replace bolts). MASONY 1. Concrete block shall be of size shown on architectural drawing and/or called for in specifications and conform to ASTM C-90-09, grade A normal weight units with max. linear shrinkage of 0.06% 2. All vertical reinforcing in masonry walls not retaining earth shall be located in the center of the wall (U.N.O.), retaining walls are to be as shown in details. 3. All cells with steel are to be solid grouted (except retaining walls where all cells are to be solid grouted). LOADING & LATERAL ANALYSIS (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number : 24077 Plan : GENERAL INPUT : Code :2022 CBC Wind Speed:110 mph Risk Category :II Wind Exposure:C Importance Factor, I (Seis.)1.00 Mean Roof Height :13.5 ft Soil Site Class :D Building With, B :31.75 ft Seismic Category :D Building Lenght, L :35.25 ft Spectral Accel., Ss :1.335 Typ. Roof Slope:6/12 Spectral Accel., S1 :0.475 Risk Category II Structure Height, hn :13.5 ft Topographic Factor Kzt 1.00 Seismic Resist. System (R) :6.5 Direction Factor Kd :0.85 Soil Bearing Pressure:1500 psf Gust Effect Factor G :0.85 Concrete Strength:2500 psi Gcpi(+/-)0.18 Foundation Type : Conventional Load Combination Factor (W) :1.00 ANALYSIS SEISMIC DESIGN :(Using Equivalent Force Procedure per ASCE 7-16) Site Coefficients : Fa ==1.20 (ASCE 7-16 Table 11.4-1) Fv ==1.80 (ASCE 7-16 Table 11.4-2) Maximum Spectral Response Accelerations : SMS=Fa*Ss =1.60 (USGS Seismic Design Geodatabase) SM1=Fv*S1 =0.86 (USGS Seismic Design Geodatabase) Design Spectral Accelerations : SDS=SMS*2/3 =1.068 SD1=SM1*2/3 =0.57 Determine Building Period : Ta=Ct*(hn^x)=0.141 sec. (Approximate Fundemental Period using Eq. 12.8-7) TL =8.000 sec. (Long-period transition period per ASCE 7-16 Maps 22-15/20) Ct =0.020 x =0.750 Seismic Response Coefficients : Cs=0.7*SDS*I/(R)=0.115 (ASCE 7-16 Section 12.8-2)CONTROL Cs-max 0.623 (Eq. 12.8-3 & 12.8-4) Cs-min 0.010 (Eq. 12.8-5 & 12.8-6) ANALYSIS WIND DESIGN :(MWFRS Directional Procedure Chapter 27 Part1 per ASCE 7-16 for Building of any Height- See detail on pages Lateral Analytical Section ) LOADDING CONDITIONS : ROOF LOADING :FLOOR LOADING : Slope : 6/12 Roof Material : 5.50 Floor Material : 4.00 Built-up : 3.50 Built-up : 0.00 Sheathing : 1.50 Sheathing : 3.00 Roof Rafters : 1.50 Floor Joist : 1.50 Ceiling Joist : 1.50 Carpet : 1.00 Drywall : 1.50 Drywall : 2.50 Miscellaneous : 5.00 Miscellaneous : 3.00 Total Dead Load(D.L) : 20.00 psf Total Dead Load(D.L) : 15.00 psf Live Load (L.L) : 20.00 psf Live Load (L.L) : 40.00 psf Snow Load : WALL LOADING :CEILING LOADING : Exterier Wall :(DL )15.00 psf Dead Load :6.00 psf Interier Wall :10.00 psf Live Load :10.00 psf BEAM DESIGN Job Number 24077 Plan :1 Code : AF&PA NDS-2018 Design Method:ASD Load Combination: 2021 IBC/2022 CBC & ASCE 7-16 All timber shall be Douglas Fir-Larch-19% max .moisture content. Timber Properties : Sawn Lumber(DFL) 2X Josit& Rafters(No.2) 4X Swan Beams(No.2) 6X Swan Beams(No.1) Glued Laminated Beam Glulam 24F-V4 DF/DF Glued Laminated Beam TimberStrand LSL 1.55E Parallam PSL 2.0E Microllam LVL 1.9E Wood Post Axial Loads Capacity: POST HEIGHT (FT) Post 7 8 9 10 12 14 18.67 22 2x4 DFL STANDARD 3.29 2.64 2.14 1.76 1.25 0.93 --- --- 2x4 DFL STUD 2.89 2.42 2.01 1.69 1.22 0.91 ------ 4x4 DFL No.2 8.73 7.00 5.69 4.69 3.33 2.48 --- --- 2x6 DFL STUD 5.16 5.16 5.16 4.93 4.00 3.18 1.94 1.43 2x6 DFL No.2 5.16 5.16 5.16 5.16 5.06 3.88 2.28 1.67 4x6 DFL No.2 13.58 10.93 8.90 7.35 5.22 3.89 --- --- 4x8 DFL No.2 17.71 14.30 11.67 9.66 6.87 5.12 --- --- 4x10 DFL No.2 22.32 18.10 14.81 12.27 8.74 6.52 ------ 4x12 DFL No.2 27.15 22.01 18.01 14.92 10.63 7.93 --- --- 6x6 DFL No.1 26.37 24.84 23.01 20.99 16.90 13.42 8.15 6.00 6x8 DFL No 1 35.96 33.87 31.38 28.62 23.05 18.30 11.11 8.19 8x8 DFL No.1 52.82 51.56 50.01 48.16 43.51 37.99 25.86 19.67 Fb Fv E 900 900 180 1.6 E 180 1.6 E 1350 170 1.6 E 265 1.8 E2400/1850 2.0 E 1.9 E 1.55 E2350 2900 2600 310 285 285 Roof Member Name Results (Max UTIL %)Current Solution Comments R1 : RR over Bedroom 1 Passed (54% M)1 piece(s) 2 x 8 DF No.2 @ 16" OC R2 : CJ over Bedroom 1 Passed (31% M)1 piece(s) 2 x 8 DF No.2 @ 16" OC 1: Ridge bm over Bedroom 2 Passed (85% ΔT)1 piece(s) 3 1/2" x 11 7/8" 1.55E TimberStrand® LSL 2 : Ridge bm over Bedroom 1 Passed (55% R)1 piece(s) 3 1/2" x 11 7/8" 1.55E TimberStrand® LSL 3 : Ridge bm over Kitchen Passed (71% M)1 piece(s) 4 x 12 DF No.2 4 : Cl'g bm over Kitchen Passed (86% ΔT)1 piece(s) 5 1/4" x 14" 2.0E Parallam® PSL 5 : HDR right of Bedroom 1 Passed (48% V)1 piece(s) 4 x 8 DF No.2 24077 JOB SUMMARY REPORT ForteWEB Software Operator Job Notes 8/14/2024 4:31:55 PM UTC Tung Vo HomeTopHome (714) 928-2006 hometophome2829@gmail.com ForteWEB v3.8 File Name: 24077 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)329 @ 2 1/2"3281 (3.50")Passed (10%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)281 @ 10 3/8"1631 Passed (17%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)919 @ 6'1700 Passed (54%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.157 @ 6'0.407 Passed (L/930)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.323 @ 6'0.610 Passed (L/453)--1.0 D + 1.0 Lr (All Spans) Member Length : 12' 10 3/16" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 4/12 •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Beveled Plate - DF 3.50"3.50"1.50"169 160 329 Blocking 2 - Beveled Plate - DF 3.50"3.50"1.50"169 160 329 Blocking •Maximum allowable bracing intervals based on applied load. •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)11' o/c Bottom Edge (Lu)12' 8" o/c Dead Roof Live Vertical Load Location (Side)Spacing (0.90)(1.25)Comments 1 - Uniform (PSF)0 to 12'16"20.0 20.0 Roof Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Roof, R1 : RR over Bedroom 1 1 piece(s) 2 x 8 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 8/14/2024 4:31:55 PM UTC Tung Vo HomeTopHome (714) 928-2006 hometophome2829@gmail.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 24077 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)144 @ 2 1/2"3281 (3.50")Passed (4%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)125 @ 10 3/4"1631 Passed (8%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)456 @ 6' 9"1478 Passed (31%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.115 @ 6' 9"0.436 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.185 @ 6' 9"0.654 Passed (L/851)--1.0 D + 1.0 Lr (All Spans) Member Length : 13' 6" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"54 90 144 Blocking 2 - Stud wall - DF 3.50"3.50"1.50"54 90 144 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)13' 6" o/c Bottom Edge (Lu)13' 6" o/c • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Roof Live Vertical Load Location (Side)Spacing (0.90)(1.25)Comments 1 - Uniform (PSF)0 to 13' 6"16"6.0 10.0 Ceiling Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Roof, R2 : CJ over Bedroom 1 1 piece(s) 2 x 8 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 8/14/2024 4:31:55 PM UTC Tung Vo HomeTopHome (714) 928-2006 hometophome2829@gmail.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 24077 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3461 @ 2"6103 (2.25")Passed (57%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)2881 @ 1' 3 3/8"10737 Passed (27%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)11935 @ 7' 1 1/2"19941 Passed (60%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.288 @ 7' 1 1/2"0.464 Passed (L/579)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.592 @ 7' 1 1/2"0.696 Passed (L/282)--1.0 D + 1.0 Lr (All Spans) Member Length : 14' 1/2" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Column - DF 3.50"2.25"1.50"1801 1710 3511 1 1/4" Rim Board 2 - Column - DF 3.50"2.25"1.50"1801 1710 3511 1 1/4" Rim Board •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)14' 1" o/c Bottom Edge (Lu)14' 1" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)1 1/4" to 14' 1 3/4"N/A 13.0 -- 1 - Uniform (PSF)0 to 14' 3" (Front)12'20.0 20.0 Roof Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Roof, 1: Ridge bm over Bedroom 2 1 piece(s) 3 1/2" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 8/14/2024 4:31:55 PM UTC Tung Vo HomeTopHome (714) 928-2006 hometophome2829@gmail.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 24077 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5249 @ 5' 3"9494 (3.50")Passed (55%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)2465 @ 6' 4 5/8"10737 Passed (23%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)-4935 @ 5' 3"19941 Passed (25%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.059 @ 10' 10 1/2"0.344 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.118 @ 10' 10 3/4"0.517 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 15' 6 1/2" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Column - DF 3.50"2.25"1.50"186 389/-110 574 1 1/4" Rim Board 2 - Column - DF 3.50"3.50"1.94"2694 2555 5249 None 3 - Column - DF 3.50"2.25"1.50"1103 1060 2163 1 1/4" Rim Board •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)15' 7" o/c Bottom Edge (Lu)15' 7" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)1 1/4" to 15' 7 3/4"N/A 13.0 -- 1 - Uniform (PSF)0 to 15' 9" (Front)12'20.0 20.0 Roof Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Roof, 2 : Ridge bm over Bedroom 1 1 piece(s) 3 1/2" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 8/14/2024 4:31:55 PM UTC Tung Vo HomeTopHome (714) 928-2006 hometophome2829@gmail.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 24077 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2161 @ 2"4922 (2.25")Passed (44%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1689 @ 1' 2 3/4"5906 Passed (29%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)5426 @ 5' 3"7614 Passed (71%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.074 @ 5' 3"0.339 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.152 @ 5' 3"0.508 Passed (L/803)--1.0 D + 1.0 Lr (All Spans) Member Length : 10' 3 1/2" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Column - DF 3.50"2.25"1.50"1128 1076 2204 1 1/4" Rim Board 2 - Column - DF 3.50"2.25"1.50"1128 1076 2204 1 1/4" Rim Board •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)10' 4" o/c Bottom Edge (Lu)10' 4" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)1 1/4" to 10' 4 3/4"N/A 10.0 -- 1 - Uniform (PSF)0 to 10' 6" (Front)10' 3"20.0 20.0 Roof Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Roof, 3 : Ridge bm over Kitchen 1 piece(s) 4 x 12 DF No.2 ForteWEB Software Operator Job Notes 8/14/2024 4:31:55 PM UTC Tung Vo HomeTopHome (714) 928-2006 hometophome2829@gmail.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 24077 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4844 @ 4"13945 (4.25")Passed (35%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)4292 @ 1' 7 1/2"17763 Passed (24%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)29362 @ 10' 3"50928 Passed (58%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.396 @ 10' 3"0.669 Passed (L/609)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.867 @ 10' 3"1.004 Passed (L/278)--1.0 D + 1.0 Lr (All Spans) Member Length : 20' 6 1/2" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Column - DF 5.50"4.25"1.50"2675 2205 4879 1 1/4" Rim Board 2 - Column - DF 5.50"4.25"1.50"2661 2191 4852 1 1/4" Rim Board •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)20' 7" o/c Bottom Edge (Lu)20' 7" o/c • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)1 1/4" to 20' 7 3/4"N/A 23.0 -- 1 - Uniform (PSF)0 to 20' 9" (Front)8'20.0 20.0 Roof 2 - Uniform (PSF)0 to 20' 9" (Front)2'10.0 -I.Wall 3 - Point (lb)10' 3" (Front)N/A 1128 1076 Linked from: 3 : Ridge bm over Kitchen, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Roof, 4 : Cl'g bm over Kitchen 1 piece(s) 5 1/4" x 14" 2.0E Parallam® PSL ForteWEB Software Operator Job Notes 8/14/2024 4:31:55 PM UTC Tung Vo HomeTopHome (714) 928-2006 hometophome2829@gmail.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 24077 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1937 @ 4' 1 1/2"6563 (3.00")Passed (30%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1838 @ 3' 4 3/4"3806 Passed (48%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)1638 @ 3' 3"3737 Passed (44%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.010 @ 2' 3 7/8"0.100 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.021 @ 2' 3 13/16"0.200 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Member Length : 4' 3" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Trimmer - DF 3.00"3.00"1.50"404 317 721 None 2 - Trimmer - DF 3.00"3.00"1.50"1024 913 1937 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)4' 3" o/c Bottom Edge (Lu)4' 3" o/c Dead Roof Live Vertical Loads Location Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 4' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 4' 3"2'15.0 -E.Wall 2 - Uniform (PSF)0 to 4' 3"2'20.0 20.0 Roof 3 - Point (lb)3' 3"N/A 1103 1060 Linked from: 2 : Ridge bm over Bedroom 1, Support 3 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Roof, 5 : HDR right of Bedroom 1 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/14/2024 4:31:55 PM UTC Tung Vo HomeTopHome (714) 928-2006 hometophome2829@gmail.com ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 File Name: 24077 SHEARWALL DESGIN GENERAL (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code)Job Number :24077 Plan : GENERAL MATERIALS Code : AF&PA NDS-2018 &SDPWS-2021(ASD) Descript. Material Size Design Method : Segment & FTAO Top Plate DF/SPine Load Combo : 2021 IBC/2022 CBC & ASCE 7-16 Sill Plate DF/SPine HD Manufacturer : SIMPSON Wall Stud DF/SPine Panel Schedule : 2022 CBC Chord DF/SPine 2X4 Min. 2022 CBC 16d's Sinker SDS Screws(*) 1 260 6" O.C. 16" O.C. 24" O.C. 2 380 4" O.C. 12" O.C. 16" O.C. 3 490 3" O.C. 8" O.C. 12" O.C. 4 640 2" O.C. 6" O.C. 10" O.C. 5 800 (2) 3" O.C. 5" O.C. 6" O.C. 3(D.S.)1020 (2) 3" O.C. 4" O.C. N/A 4(D.S.)1330 (2) 3" O.C. 3" O.C. N/A 5(D.S.)1740 (2) 3" O.C. 2.5" O.C. N/A Notes: -(*) Use 1/4"dia. x6"SDS Screws DRAG TYPE FORCE SCHEDULE Type A B C D E F FORMULAS MAXIMUM SHEAR WALL DEFLECTION: ( IBC Section 2305.3 / SDPWS-08 4.3.2) Top Plate Splice Simpson MST48 or ALT.(32)16d sinker per top plate splice -(2) Clips Framing Use A35's, LS50's or LTP4's. -Periodic Special Inspection is Required. -Use Spacing Per Schedule If Number Of Framing Clips Are Not Specified On Framing Plans. -For Holdown Attached To Inside Face Of End Post. Load Capacity Simpson MSTC52 or ALT.(36)16d sinker per top plate splice 1192 2134 3230 4267 4745 5653 Simpson ST22 or ALT.(10)16d sinker per top plate splice Simpson ST6224 or ALT.(16)16d sinker per top plate splice Simpson ST6236 or ALT.(22)16d sinker per top plate splice Simpson MST37 or ALT.(24)16d sinker per top plate splice Sill Plate Connection Framing(2) Clips SHEAR WALL SCHEDULE of 10d's @ 12" O.C. 15/32" Allowable Shear(plf)Sheathing (Plywood/OSB) 3/8" 15/32" 8d's @ 6" O.C. 8d's @ 4" O.C. 8d's @ 3" O.C. 8d's @ 12" O.C. 8d's @ 12" O.C. 8d's @ 12" O.C. 8d's @ 12" O.C. 3/8" 15/32" 10d's @ 4" O.C. 10d's @ 3" O.C. 10d's @ 12" O.C. 10d's @ 12" O.C. 10d's @ 12" O.C. 15/32" Panel Type Edge Nail (common) Field Nail (common) 3/8" 3/8" -Provide 3" Nominal Or Wider Framing At Adjoining Panel Edges With Nails Staggered. -Use Clips @ 6" O.C. On Simpson Strong Wall & Hardy Frame (U.N.O.). -Use Spacing Per Schedule If Number Of Framing Clips Are Not Specified On Framing Plans. -Sheathing Conforms to Either Doc PS 1 Or PS 2 Standards. 8d's @ 2" O.C. 10d's @ 2" O.C. 10d's @ 2" O.C. -Sheathing Panel Joint And Sill Plate Nailing Shall Be Staggered In All Cases. 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D BATH 2 BATH 1 W/D WH BEDROOM 1 BEDROOM 2 BEDROOM 3 DINING LIVING REF. KITCHEN PANTRY Job Number : 24077LATERAL SHEAR WALL LAYOUT Plan : ROOF SHEAR WALL LAYOUT A SECTION 1 1 SECTION 2 2 3 B C LATERAL ANALYTICAL SECTION (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code)Job Number : 24077 1 Plan : GENERAL INPUT : (1 STORY) Base Height Above Ground (ft)0.50 Plate Height (ft)10.00 South Roof Height (N-S Direction-ft)17.00 West Roof Height (E-W Direction-ft)14.75 South Roof Type (N-S Direction) Slope West Roof Type (E-W Direction) Gable Roof Depth (N-S-ft)26.75 Roof Depth (E-W-ft)32.5 Diaphragm Depth (N-S Direction-ft)24.75 Diaphragm Depth (E-W Direction-ft)31.75 Diaphragm Span (N-S Direction-ft)31.75 Diaphragm Span(E-W Direction-ft)24.75 Number of Ext. Wall (N-S)2 Number of Ext. Wall (E-W)2 Number of Int. Wall (N-S)2 Number of Int. Wall (E-W)2 SEISMIC ANALYSIS :(Using Equivalent Force Procedure per ASCE 7-16) Determine Section Weight : For N-S Direction : Area(ft^2) Unit Roof 869.375 20 Ext.Wall(ft.)317.5 15 Int. Wall(ft)317.5 10 Sum:25,325 Ev(ASD) Base Shear :(V=Cs*W) :2,912.8 5409 lbs 3.35 89.6125 For E-W Direction : Area(ft^2) Unit Roof 869.375 20 Ext.Wall(ft.)247.5 15 Int. Wall(ft)247.5 10 Sum:23,575 Ev(ASD) Base Shear :(V=Cs*W) :2,711.5 5036 lbs 3.12 101.4 WIND ANALYSIS :(MWFRS Directional Procedure Chapter 27 Part1 per ASCE 7-16 for Building of any Height) The Velocity Pressures : qz = 0.00256 Kz Kzt Kd V2 (ASCE 7-16 Equation27.3-1) Kzt = 1.0 (Flat Terrian) Kd = 0.85 (ASCE 7-16 Table 26.6-1) Kz = 2.01*(max(z,15)/zg)(2/a)( ASCE 7-16 Tables 27.3-1) h(ft)kz qz(psf) Roof 14.67 0.849 22.35 Wall 10.00 0.849 22.35 p=qz*G*Cp-qi*(+/-GCpi) for windward wall (psf), where : qi=qh(Eq. 27.3-1, Sect.27.3.2) p=qh*G*Cp-qi*(+/-GCpi) for leeward wall, side wall & roof (psf), where : qi=qh( Eq. 27.3-1, Sect.27.3.2) The Internal Pressures: Gcpi(+/-) 0.18 qh 22.35 psf +qhGCpi 4.02 psf -qhGCpi -4.02 psf (see next page for details) SECTION NUMBER : Weight(Ib) 17387.5 4762.5 3175 Unit FN-S(psf) Unit FN-S(plf) Weight(Ib) 17387.5 3712.5 2475 Unit FE-W(psf) Unit FE-W(plf) LATERAL ANALYTICAL SECTION (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number : 24077 SECTION NUMBER : 1 (cont.)Plan : Normal to Ridge Wind Load Tabulation for MWFRS with q ≥ 10o(N-S Direction): (w/+Gcpi) (w/-Gcpi) All 0.80 22.35 19.22 11.18 Cond.1 -0.26 22.35 -0.99 -9.03 Cond.2 0.21 22.35 7.95 -0.09 All -0.60 22.35 -7.38 -15.42 All -0.48 22.35 -5.06 -13.10 All -0.70 22.35 -9.28 -17.32 Design Sumary Wind Loading (N-S Direction): Horizontal Vertical Roof 13.71 6.90 1st Floor 24.28 0.00 217.38 plf Parallel to Ridge Wind Load Tabulation for MWFRS (E-W Direction): (w/+Gcpi) (w/-Gcpi) Roof 0.80 22.35 19.22 11.18 Wall 0.80 22.35 19.22 11.18 Cond.1 -0.90 22.35 -13.08 -21.12 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 -0.90 22.35 -13.08 -21.12 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 -0.50 22.35 -5.48 -13.52 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 -0.30 22.35 -1.68 -9.72 Cond.2 -0.18 22.35 0.60 -7.44 All -0.50 22.35 -5.48 -13.52 All -0.70 22.35 -9.28 -17.32 Design Sumary Wind Loading (E-W Direction): Horizontal Vertical Roof 24.70 9.45 Wall 24.70 0.00 240.83 plf DIAPHRAGMS ANALYSIS (ASD METHOD) : Design Sumary Loading : Seis.(N-S)Wind(N-S)Govern Seis.(E-W)Wind (E-W)Govern Roof 89.6 130.4 Wind 101.4 144.5 Wind For N-S Direction : Max. Diaphragm Shear @ Roof : Vn-s=wL/2B 57.09 plf < 180 plf OK USE : 15/32" APA(OR OSB) RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. UNBOCKLED DIAPHRAGMS W/8d @ COMMON NAIL @ 6" O.C. B.N., 6" O.C. E.N., 12' O.C F.N. CHORD FORCE :157.12 SPICE W/ MINI (5)16d SINKER EACH SIDE OF SPLICE @ 8" O.C.(STANDARD CONSTRUCTIONS) For E-W Direction : Max. Diaphragm Shear @ Roof : Ve-w=wL/2B 60.87 plf < 180 plf OK USE : 15/32" APA(OR OSB) RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. UNBOCKLED DIAPHRAGMS W/8d @ COMMON NAIL @ 6" O.C. B.N., 6" O.C. E.N., 12' O.C F.N. CHORD FORCE :324.72 SPICE W/ MINI (5)16d SINKER EACH SIDE OF SPLICE @ 8" O.C.(STANDARD CONSTRUCTIONS) Surface Location Cp q(psf)qGCp(psf)Net Pressure (psf) Windward Wall 15.20 Windward Roof -5.01 3.93 Leeward Roof -11.40 Leeward Wall -9.08 Side Walls -13.30 Location Net Pressure (psf) Surface Location Cp q(psf)qGCp(psf)Net Pressure (psf) Windward Wall 15.20 15.20 Leeward Wall -9.50 Side Walls -13.30 Location Net Pressure (psf) Windward Roof 0 to h/2 -17.10 -3.42 h/2 to h -17.10 -3.42 h to 2h -9.50 -3.42 >2h -5.70 -3.42 LATERAL ANALYTICAL SECTION (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code)Job Number : 24077 2 Plan : GENERAL INPUT : (1 STORY) Base Height Above Ground (ft)0.50 Plate Height (ft)10.00 South Roof Height (N-S Direction-ft)14.75 West Roof Height (E-W Direction-ft)17.00 South Roof Type (N-S Direction) Gable West Roof Type (E-W Direction) Slope Roof Depth (N-S-ft)10.5 Roof Depth (E-W-ft)24.75 Diaphragm Depth (N-S Direction-ft)10.5 Diaphragm Depth (E-W Direction-ft)21.25 Diaphragm Span (N-S Direction-ft)21.25 Diaphragm Span(E-W Direction-ft)10.5 Number of Ext. Wall (N-S)1 Number of Ext. Wall (E-W)2 Number of Int. Wall (N-S)0 Number of Int. Wall (E-W)0 SEISMIC ANALYSIS :(Using Equivalent Force Procedure per ASCE 7-16) Determine Section Weight : For N-S Direction : Area(ft^2) Unit Roof 259.875 20 Ext.Wall(ft.)106.25 15 Int. Wall(ft)0 10 Sum:6,791 Ev(ASD) Base Shear :(V=Cs*W) :781.1 1451 lbs 3.01 31.605 For E-W Direction : Area(ft^2) Unit Roof 259.875 20 Ext.Wall(ft.)105 15 Int. Wall(ft)0 10 Sum:6,773 Ev(ASD) Base Shear :(V=Cs*W) :778.9 1447 lbs 3 74.3 WIND ANALYSIS :(MWFRS Directional Procedure Chapter 27 Part1 per ASCE 7-16 for Building of any Height) The Velocity Pressures : qz = 0.00256 Kz Kzt Kd V2 (ASCE 7-16 Equation27.3-1) Kzt = 1.0 (Flat Terrian) Kd = 0.85 (ASCE 7-16 Table 26.6-1) Kz = 2.01*(max(z,15)/zg)(2/a)( ASCE 7-16 Tables 27.3-1) h(ft)kz qz(psf) Roof 13.17 0.849 22.35 Wall 10.00 0.849 22.35 p=qz*G*Cp-qi*(+/-GCpi) for windward wall (psf), where : qi=qh(Eq. 27.3-1, Sect.27.3.2) p=qh*G*Cp-qi*(+/-GCpi) for leeward wall, side wall & roof (psf), where : qi=qh( Eq. 27.3-1, Sect.27.3.2) The Internal Pressures: Gcpi(+/-) 0.18 qh 22.35 psf +qhGCpi 4.02 psf -qhGCpi -4.02 psf (see next page for details) SECTION NUMBER : Weight(Ib) 5197.5 1593.75 Weight(Ib) 5197.5 1575 0 Unit FN-S(psf) Unit FN-S(plf) 0 Unit FE-W(psf) Unit FE-W(plf) LATERAL ANALYTICAL SECTION (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number : 24077 SECTION NUMBER : 2 (cont.)Plan : Parallel to Ridge Wind Load Tabulation for MWFRS (E-W Direction): (w/+Gcpi) (w/-Gcpi) All 0.80 22.35 19.22 11.18 Cond.1 -0.26 22.35 -0.99 -9.03 Cond.2 0.21 22.35 7.95 -0.09 All -0.60 22.35 -7.38 -15.42 All -0.50 22.35 -5.48 -13.52 All -0.70 22.35 -9.28 -17.32 Design Sumary Wind Loading (E-W Direction): Horizontal Vertical Roof 13.71 6.90 1st Floor 24.70 0.00 188.63 plf Normal to Ridge Wind Load Tabulation for MWFRS with q ≥ 10o(N-S Direction): (w/+Gcpi) (w/-Gcpi) Roof 0.80 22.35 19.22 11.18 Wall 0.80 22.35 19.22 11.18 Cond.1 -0.90 22.35 -13.08 -21.12 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 -0.90 22.35 -13.08 -21.12 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 -0.50 22.35 -5.48 -13.52 Cond.2 -0.18 22.35 0.60 -7.44 Cond.1 N/A N/A N/A N/A Cond.2 N/A N/A N/A N/A All -0.48 22.35 -5.06 -13.10 All -0.70 22.35 -9.28 -17.32 Design Sumary Wind Loading (N-S Direction): Horizontal Vertical Roof 24.28 9.45 Wall 24.28 0.00 291.36 plf DIAPHRAGMS ANALYSIS (ASD METHOD) : Design Sumary Loading : Seis.(N-S)Wind(N-S)Govern Seis.(E-W)Wind (E-W)Govern Roof 31.6 174.8 Wind 74.3 113.2 Wind For N-S Direction : Max. Diaphragm Shear @ Roof : Vn-s=wL/2B 137.36 plf < 180 plf OK USE : 15/32" APA(OR OSB) RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. UNBOCKLED DIAPHRAGMS W/8d @ COMMON NAIL @ 6" O.C. B.N., 6" O.C. E.N., 12' O.C F.N. CHORD FORCE :76.48 SPICE W/ MINI (5)16d SINKER EACH SIDE OF SPLICE @ 8" O.C.(STANDARD CONSTRUCTIONS) For E-W Direction : Max. Diaphragm Shear @ Roof : Ve-w=wL/2B 27.96 plf < 180 plf OK USE : 15/32" APA(OR OSB) RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. UNBOCKLED DIAPHRAGMS W/8d @ COMMON NAIL @ 6" O.C. B.N., 6" O.C. E.N., 12' O.C F.N. CHORD FORCE :203.91 SPICE W/ MINI (5)16d SINKER EACH SIDE OF SPLICE @ 8" O.C.(STANDARD CONSTRUCTIONS) Windward Wall 15.20 Windward Roof -5.01 3.93 Surface Location Cp q(psf)qGCp(psf)Net Pressure (psf) Location Net Pressure (psf) Surface Location Cp q(psf) Leeward Roof -11.40 Leeward Wall -9.50 Side Walls -13.30 qGCp(psf)Net Pressure (psf) Windward Wall 15.20 15.20 Windward Roof 0 to h/2 -17.10 -3.42 h/2 to h Leeward Wall -9.08 Side Walls -13.30 Location Net Pressure (psf) -17.10 -3.42 h to 2h -9.50 -3.42 >2h N/A N/A JOB NUMBER : 24077 PLAN: Story 1 Line :1 Redundancy(ρ)1.3 Y Dir. Lateral loads : at A Max. Drag Force : 774 lb Use Drag Type A (See Shear wall Schedule) Total Wall Length : 24.75 ft Total Panel Length : 8.00 ft Net Length : 8.00 ft Shear Diaphragm : 84 plf Design Wall Shear : 259 plf Use ( 5 A35) or (4 LS50) Along Line Shear Panel or for Framing Clips Spacing See S.W. Schedule USE TYPE 2 ok Ratio Shear : 0.68 Max. Panel Deflection :1.307 " < 2.4 "ok Holdown & Deflection Check A 8.00 8.00 10 2348 2790 2348 2790 4X4 4X4 3 40" Uplift Above 00 lbs Span(ft) Seis. (lbs) Wind (lbs) From Line 1 Lateral Loads: 0% 0 0 Post size Panel Length (ft) Net L (ft) Height (ft) Left Seis. Wall (lbs)190 Down (lb) 1Y_ROOF 31.75 24.75 1711 2071 Sum :1901 2071 Right Span (ft) Deep (ft) Wind (lbs)Seis. (lbs) (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) SHEAR WALL DESIGN Deflection (in.)A.B.Spacing (in.) HDU2 HDU2 0.2334 Holdown L. R.Uplift (lb) Down (lb)Holdown Uplift (lb) DM = (4.0/1.0) X Ds X 1.4 = 0 3.5 7.5 17.25 21.25 24.7524.7524.7524.7524.7524.75 7.5 15.50000000000 A JOB NUMBER : 24077 PLAN: Story 1 Line :2 Redundancy(ρ)1.3 Y Dir. Lateral loads : at A Max. Drag Force : 796 lb Use Drag Type A (See Shear wall Schedule) Total Wall Length : 10.50 ft Total Panel Length : 6.00 ft Net Length : 6.00 ft Shear Diaphragm : 177 plf Design Wall Shear : 310 plf Use ( 5 A35) or (4 LS50) Along Line Shear Panel or for Framing Clips Spacing See S.W. Schedule USE TYPE 2 ok Ratio Shear : 0.81 Max. Panel Deflection :1.722 " < 2.4 "ok Holdown & Deflection Check A 6.00 6.00 10 3031 3359 3031 3359 4X4 4X4 2 56" Holdown L. R.Uplift (lb) Down (lb)Holdown Uplift (lb) Span (ft) Deep (ft) Wind (lbs)Seis. (lbs) (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) SHEAR WALL DESIGN Deflection (in.)A.B.Spacing (in.) HDU4 HDU4 0.3075 21.25 10.5 437 1857 Sum :507 1857 Right 2Y_ROOF Post size Panel Length (ft) Net L (ft) Height (ft) Left Seis. Wall (lbs)71 Down (lb) Span(ft) Seis. (lbs) Wind (lbs) From Line 1 Lateral Loads: 0% 0 0 Uplift Above 00 lbs DM = (4.0/1.0) X Ds X 1.4 = 0 1 4.5 10.510.510.510.510.510.510.510.5 4.5 10.50000000000 A JOB NUMBER : 24077 PLAN: Story 1 Line :3 Redundancy(ρ)1.3 Y Dir. Lateral loads : at A Max. Drag Force : 1620 lb Use Drag Type B (See Shear wall Schedule) Total Wall Length : 35.50 ft Total Panel Length : 13.75 ft Net Length : 13.51 ft Shear Diaphragm : 111 plf Design Wall Shear : 291 plf Use ( 10 A35) or (7 LS50) Along Line Shear Panel or for Framing Clips Spacing See S.W. Schedule USE TYPE 2 ok Ratio Shear : 0.76 Max. Panel Deflection :1.927 " < 2.4 "ok Holdown & Deflection Check A 9.00 9.00 10 2568 3056 2568 3056 4X4 4X4 3 40" B 4.75 4.51 10 2890 3150 2890 3150 4X4 4X4 2 40" Holdown L. R.Uplift (lb) Down (lb)Holdown Uplift (lb) Span (ft) Deep (ft) Wind (lbs)Seis. (lbs) (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) SHEAR WALL DESIGN Deflection (in.)A.B.Spacing (in.) HDU2 HDU2 HDU2HDU2 0.2458 0.3441 31.75 24.8 1711 2071 1857 Sum :2418 3928 Right 1Y_ROOF 2Y_ROOF 21.25 10.5 437 Post size Panel Length (ft) Net L (ft) Height (ft) Left Seis. Wall (lbs)270 Down (lb) Span(ft) Seis. (lbs) Wind (lbs) From Line 1 Lateral Loads: 0% 0 0 From Line 100% 0 0 Uplift Above 00 lbs DM = (4.0/1.0) X Ds X 1.4 = 0 9.25 13.25 16.25 20.25 26.75 30.75 35.535.535.535.5 0 9 22 26.7500000000 A B JOB NUMBER : 24077 PLAN: Story 1 Line :A Redundancy(ρ)1.3 X Dir. Lateral loads : at A Max. Drag Force : 982 lb Use Drag Type A (See Shear wall Schedule) Total Wall Length : 30.50 ft Total Panel Length : 8.00 ft Net Length : 8.00 ft Shear Diaphragm : 59 plf Design Wall Shear : 224 plf Use ( 5 A35) or (4 LS50) Along Line Shear Panel or for Framing Clips Spacing See S.W. Schedule USE TYPE 2 ok Ratio Shear : 0.59 Max. Panel Deflection :1.134 " < 2.4 "ok Holdown & Deflection Check A 8.00 8.00 10 2053 2424 2053 2424 4X4 4X4 3 40" Holdown L. R.Uplift (lb) Down (lb)Holdown Uplift (lb) Span (ft) Deep (ft) Wind (lbs)Seis. (lbs) (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) SHEAR WALL DESIGN Deflection (in.)A.B.Spacing (in.) HDU2 HDU2 0.2025 24.75 30.5 1531 1788 Sum :1773 1788 Right 1X_ROOF Post size Panel Length (ft) Net L (ft) Height (ft) Left Seis. Wall (lbs)243 Down (lb) Span(ft) Seis. (lbs) Wind (lbs) From Line 1 Lateral Loads: 0% 0 0 Uplift Above 00 lbs DM = (4.0/1.0) X Ds X 1.4 = 0 13.75 16.75 20 22.5 30.530.530.530.530.530.5 5.75 13.750000000000 A JOB NUMBER : 24077 PLAN: Story 1 Line :B Redundancy(ρ)1.3 X Dir. Lateral loads : at A Max. Drag Force : 1745 lb Use Drag Type B (See Shear wall Schedule) Total Wall Length : 31.75 ft Total Panel Length : 6.00 ft Net Length : 6.00 ft Shear Diaphragm : 75 plf Design Wall Shear : 397 plf Use ( 6 A35) or (5 LS50) Along Line Shear Panel or for Framing Clips Spacing See S.W. Schedule USE TYPE 3 ok Ratio Shear : 0.81 Max. Panel Deflection :1.947 " < 2.4 "ok Holdown & Deflection Check A 6.00 6.00 10 3970 4278 3970 4278 4X4 4X4 2 56" Uplift Above 00 lbs Span(ft) Seis. (lbs) Wind (lbs) From Line 1 Lateral Loads: 0% 0 0 From Line 100% 0 0 Post size Panel Length (ft) Net L (ft) Height (ft) Left Seis. Wall (lbs)144 Down (lb) 1X_ROOF 2X_ROOF 10.5 21.25 435 24.75 31.8 1594 1788 594 Sum :2173 2382 Right Span (ft) Deep (ft) Wind (lbs)Seis. (lbs) (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) SHEAR WALL DESIGN Deflection (in.)A.B.Spacing (in.) HDU4 HDU4 0.3477 Holdown L. R.Uplift (lb) Down (lb)Holdown Uplift (lb) DM = (4.0/1.0) X Ds X 1.4 = 0 1 2.5 8.5 10 11 31.2531.7531.7531.7531.75 2.5 8.50000000000 A JOB NUMBER : 24077 PLAN: Story 1 Line :C Redundancy(ρ)1.3 X Dir. Lateral loads : at A Max. Drag Force : 262 lb Use Drag Type A (See Shear wall Schedule) Total Wall Length : 21.25 ft Total Panel Length : 4.00 ft Net Length : 3.20 ft Shear Diaphragm : 28 plf Design Wall Shear : 150 plf Use ( 2 A35) or (2 LS50) Along Line Shear Panel or for Framing Clips Spacing See S.W. Schedule USE TYPE 2 ok Ratio Shear : 0.40 Max. Panel Deflection :1.118 " < 2.4 "ok Shear Wall Design A 4.00 10 2.50 Holdown & Deflection Check A 4.00 3.20 10 1523 1729 1523 1729 4X4 4X4 2 32" Holdown L. R. H/L Adjust Factor Actual (plf)Height (ft) Length (ft)SW Type Allowable (plf) 380 Uplift (lb) Down (lb)Holdown Uplift (lb) 0.800 150 Span (ft) Deep (ft) Wind (lbs)Seis. (lbs) (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) SHEAR WALL DESIGN Deflection (in.)A.B.Spacing (in.) HDU2 HDU2 0.1996 10.5 21.3 435 594 Sum :601 594 Right 2 2X_ROOF Post size Panel Length (ft) Net L (ft) Height (ft) Left Seis. Wall (lbs)166 Down (lb) Panel Span(ft) Seis. (lbs) Wind (lbs) From Line 1 Lateral Loads: 0% 0 0 Uplift Above 00 lbs DM = (4.0/1.0) X Ds X 1.4 = 0 5 8 13.25 16.25 21.2521.2521.2521.2521.2521.25 8 120000000000 A FOOTING & PAD DESIGN (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number : 24077 Plan : ID: F1 Ext. Footing (Design Footing ) Loading :Design : Load Type Span(ft) Unit Loads(plf) Total Weight :plf E.Wall 10.00 lbs Roof 14 Footing With Required : in. None 0 Use 12 in. With x 24 in. Deep Cont. Footing. None 0 Capacity of Point Load on Footing:lbs Self Weight Check with lateral Loads :150 plf OK ID: P1 Pad support 2-Beam #2 + 1-Beam #2 (Design Footing & Pad on Footing) Loading :Design : Load Type Span(ft) Unit Loads(plf) Total Weight :plf I.Wall 10.00 10*10 Total Point Load : lbs None 0 0 Footing With Required : in. None 0 0 None 0 0 Capacity of Point Load on Footing:lbs Self Weight 225 Allowable Point Load on Footing : lbs Required Pad Width :in. Use 2' SQ x 24 in. Deep w/(3)#4 @ Bott. E.W. for Pad ID: P2 Pad support 2-Beam #2 (Design Footing & Pad on Footing) Loading :Design : Load Type Span(ft) Unit Loads(plf) Total Weight :plf I.Wall 10.00 10*10 Total Point Load : lbs None 0 0 Footing With Required : in. None 0 0 None 0 0 Capacity of Point Load on Footing:lbs Self Weight 225 Allowable Point Load on Footing : lbs Required Pad Width :in. Use 2' SQ x 24 in. Deep w/(3)#4 @ Bott. E.W. for Pad ID: P3 Pad support 1&2-Beam #4 (Design Footing & Pad on Footing) Loading :Design : Load Type Span(ft) Unit Loads(plf) Total Weight :plf E.Wall 9.00 lbs None 0 Footing With Required : in. None 0 None 0 Capacity of Point Load on Footing:lbs Self Weight Allowable Point Load on Footing : lbs Required Pad Width :in. Use 2' SQ x 24 in. Deep w/(3)#4 @ Bott. E.W. for Pad 430.492 10*15 Total Point Load :0 14*(20+20)/2 3.5 0 1.392 5000.0 0.492 325 4100 2.6 1.88 5000 3917 1.66 325 5300 2.6 5000 3917 1.81 360 9*15 Total Point Load :4900 0 2.9 0 0 5000.0 225 3800.0 ASCE Hazards Report Address: 401 W Jonquil Rd Santa Ana, California 92706 Standard:ASCE/SEI 7-16 Latitude:33.772111 Risk Category:II Longitude:-117.8716 Soil Class:D - Default (see Section 11.4.3) Elevation:143.63228013429054 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Mon Aug 12 2024 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. https://ascehazardtool.org/Mon Aug 12 2024 SS : 1.335 S1 : 0.475 F a : 1.2 F v : N/A SMS : 1.602 SM1 : N/A SDS : 1.068 SD1 : N/A T L : 8 PGA : 0.562 PGA M : 0.675 F PGA : 1.2 Ie : 1 C v : 1.367 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Mon Aug 12 2024 https://ascehazardtool.org/Mon Aug 12 2024 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. https://ascehazardtool.org/Mon Aug 12 2024