Loading...
HomeMy WebLinkAbout3535 W Garry Ave - Racks - PlanAL L I D E A S , C O N C E P T S , D E S I G N S , A R R A N G E M E N T S A N D P L A N S I N D I C A T E D O R R E P R E S E N T E D B Y T H I S D R A W I N G A R E O W N E D B Y A N D T H E P R O P E R T Y O F K O B R A D E S I G N A N D W E R E C R E A T E D , E V O L V E D A N D D E V E L O P E D F O R U S E O N A N D I N C O N N E C T I O N W I T H T H E S P E C I F I E D P R O J E C T . N O N E O F S U C H I D E A S , C O N C E P T S , D E S I G N S , A R R A N G E M E N T S O R P L A N S S H A L L B E U S E D B Y O R DI S C L O S E D T O A N Y P E R S O N , F I R M O R C O R P O R A T I O N F O R A N Y P U R P O S E , W H A T S O E V E R , W I T H O U T T H E W R I T T E N P E R M I S S I O N O F K O B R A D E S I G N . F I L I N G T H E S E D R A W I N G S O R S P E C I F I C A T I O N S W I T H A N Y P U B L I C A G E N C Y I S N O T P U B L I C A T I O N O F S A M E A N D N O C O P Y I N G , R E P R O D U C T I O N O R U S E T H E R E O F I S P E R M I S S I B L E W I T H O U T T H E C O N S E N T O F K O B R A D E S I G N . tw o - t i e r s t o r a g e r a c k s 35 3 5 w e s t g a r r y a v e n u e sa n t a a n a , c a 9 2 7 0 4 submittals & revisions sheet: project no: date: kdg-2024-118 04-08-2024 M A S T E R P L A N N I N G I N T E R I O R D E S I G N kobra design group inc 17151 newhope st, suite 108 fountain valley ca 92708 eml: hja@kobradesign.net mbl:714.313.6815 ca:714.962.5315 az:928.714.6909 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL NEW & EXISTING DIMENSIONS, NEW & EXISTING ROOF SLOPES, NEW & EXISTING HEIGHTS AND GENERAL EXISTING CONDITIONS THEREON BEFORE COMMENCING WORK. REPORT ANY DISCREPANCIES AND/OR POTENTIAL PROBLEMS TO THE DESIGNER AND STRUCTURAL ENGINEER PRIOR TO PROCEEDING. ALL CONSTRUCTION SHALL CONFORM TO THE CBC. A R C H I T E C T U R E S P A C E P L A N N I N G BUILDING DEPT SUBMITTAL 07.05.2024 1 plot date:2024.09.10 PLAN CHECK CORRECTIONS 09.10.2024 54" PREFERRED48" MINIMUM WHERE ADJACENT OBSTRUCTION OR WALL OCCURS 12" MINIMUM IF DOOR HAS BOTH A CLOSER AND A LATCH REQUIRED CLEAR SPACE 36" MINIMUM 2X WOOD BLOCKING AS REQUIRED 1'-6" MIN 22 GA. SATIN FINISH S.S. COVER 3-1/4" DIA. SNAP O/ FLANGE 18" MIN. 24" MIN. CONCEALED EXPOSED 1-1/4" DIA. 18 GA S.S. TUBING 12" 48" MIN. 18" MIN. INTERIOR 24" MIN. EXTERIOR REQUIRED CLEAR SPACE DOOR WIDTH PLUS A PLAN 24" MIN. EXTERIOR 18" MIN. INTERIOR 24" MIN. EXTERIOR & 18" MINIMUM INTERIOR BEYOND STRIKE EDGE OF A GATE OR DOOR ON THE SIDE TOWARD WHICH IT SWINGS. 48" MINIMUM INTERIOR 18" MIN. 32" CLEAR OF BLDG. 24" MIN. EXTERIOR 54" MIN. B CORRIDOR PLAN 22" MIN. GRAB BAR BOBRICK # 5806.99 36" MIN. CLR.36" MIN. CLR.36" MIN. (2) 1/2" DIA. EXPOSED BOLTS MIN. DOOR WIDTH PLUS 42" B RAMP LANDING ATDOORWAY PLAN C VESTIBULE PLAN NOTES: 1. 2. CLEAR SPACES MUST BE LEVEL TO PREVENT WHEELCHAIRS FROM ROLLING WHEN THE OCCUPANT RELEASES THE WHEEL GRIPS TO REACH FOR THE DOOR. 1/4" PER FOOT IS ALLOWED FOR DRAINAGE. WHERE DOORS OPEN ONTO, BUT NOT INTO A CORRIDOR, THE REQUIRED LEVEL AREA BEYOND THE DOORS MAY BE A MINIMUM OF 48". FOR ADDITIONAL INFORMATION, SEE APPLICABLE NOTES ON TYPICAL ACCESSIBILITY NOTES SHEET. 48" 8" MIN. KNEE CLEARANCE 1'-5" MIN. DEPTH 6" MAX. TOE CLEARANCE 18" TO 19" 24" MIN. 48" 20" MAX. >20-25" MAX. DOOR TYPE: 1. EITHER ATTACHED PANEL OR BOTTOM RAIL. MINIMUM 10" HIGH SMOOTH SURFACE AT DOOR BOTTOM, HARDWARE: 4. 3. 2.OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL OPENABLE BY SINGLE EFFORT LEVER-TYPE DEVICE (NOT KNOWLEDGE OR EFFORT. MOUNTED 36" TO 42". REQUIRING GRASPING). 5. MAXIMUM 5 LBS. EFFORT TO OPERATE EXTERIOR DOOR, 5 LBS. FOR INTERIOR. WOMENS RESTROOMS MENS 10" 30"MAX 10">10-24" MAX. EXIT EXIT (BRAILLE) N O T E: REACH RANGES SHALL COMPLY WITH 2019 CBC CHAPTER 11B SECTION 308 TYPICAL DIMENSIONS ROUTE (BRAILLE) RAIL OR PROVIDE 10" MIN. BOTTOM KICK PLATE OR U SHAPED 36" TO 42" LEVER HANDLE EXIT STAIR DOWN (BRAILLE)DETAIL RUBBER BUMPER ON CHAIR 48 " M A X . 60 " M I N I M U M 48 M A X . " 34 " M A X . 48 " M A X . 15 " MI N . 48 " M I N I M U M DO O R W I D T H P L U S 4 2 " 46 " M A X . 48 " M A X . 34 " M A X . 15 " MI N . 48 " M I N I M U M 44 " M A X . 30 " 48 " M I N . 9" M I N . 2' - 3 " M I N . 3' - 0 " M A X . 6" MA X . 30 " 42 " 27 " 34 " 34 " 27 " * 4 4 " M I N . 60 " M I N . 48 " M I N . 60 " M I N . . * 4 4 " M I N . 60 " M I N . A0.1 accessibility notes (for reference only) BUILDING DEPT RESUBMITTAL, DELTA-1 1,000 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 700 GAL. WATER TANK 1,000 GAL. WATER TANK UP UP 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 87654321 D B E C A EXIT SIGNAGE, TYP. REFER TO ELECTRICAL. ACCESSIBLE SIGNAGE AT ENTRY, TYP. AND EACH GRADE LEVEL EXTERIOR DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT WITH THE WORD "EXIT", TYP. EXIT SIGNAGE, TYP. REFER TO ELECTRICAL. ACCESSIBLE SIGNAGE AT ENTRY, TYP. AND EACH GRADE LEVEL EXTERIOR DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT WITH THE WORD "EXIT", TYP. EXIT SIGNAGE, TYP. REFER TO ELECTRICAL. ACCESSIBLE SIGNAGE AT ENTRY, TYP. AND EACH GRADE LEVEL EXTERIOR DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT WITH THE WORD "EXIT", TYP. DIAGO N A L D I S T A N C E 2 0 9 ' - 2 " ( 1 / 3 ) S P R I N K E R E D = 6 9 ' - 9 " F.E. F.E. F.E. F.E. F.E. F.E. F.E. MAXIMUM TRAVEL DISTANCE: 300' CURRENT TRAVEL DISTANCE: 129' MAXIMUM TRAVEL DISTANCE: 300' CURRENT TRAVEL DISTANCE: 142' EXIT SIGNAGE, TYP. REFER TO ELECTRICAL. ACCESSIBLE SIGNAGE AT ENTRY, TYP. AND EACH GRADE LEVEL EXTERIOR DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT WITH THE WORD "EXIT", TYP. 143'-7" SEPARATION BETWEEN EXITS MAXIMUM TRAVEL DISTANCE: 300' CURRENT TRAVEL DISTANCE: 210' MAXIMUM TRAVEL DISTANCE: 300' CURRENT TRAVEL DISTANCE: 130' F.E. DEAD END CORRIDOR ALLOWABLE DISTANCE: 20' CURRENT TRAVEL DISTANCE: 12' FLOWER ROOM 1 101 1,458 SF FLOWER ROOM 2 102 1,462 SF FLOWER ROOM 3 103 1,462 SF FLOWER ROOM 4 104 1,462 SF FLOWER ROOM 5 105 1,290 SF FLOWER ROOM 6 106 1,290 SF FLOWER ROOM 7 107 1,290 SF FLOWER ROOM 8 108 1,302 SF CORRIDOR 1 126 1,312 SF IRRIGATION TANK ROOM 114 1,144 SF ELECTRICAL ROOM 2 124 300 SF GARAGE 132 318 SF SHIPPING & RECEIVING 109 216 SF CIRCULATION 1 130 835 SF EMPLOYEE BREAK ROOM 115 316 SF F. LOCKER 116 165 SF M. LOCKER 117 167 SF WATER HEATER 125 22 SF CORRIDOR 4 129 118 SF SECURITY 118 134 SF PUBLIC ENTRANCE 131 148 SF RESTROOM 1 119 116 SF RESTROOM 2 120 108 SF AIR SHOWER 121 92 SF CORRIDOR 3 128 157 SF SECURE PRODUCT STORAGE 112 232 SF TRIMMING & POST PROCESSING 113 786 SF CORRIDOR 2 127 627 SF DRY / CURE 1 110 456 SF DRY / CURE 2 111 448 SF LAUNDRY ROOM 123 214 SF IT ROOM 122 148 SF RESTROOM 3 133 105 SF STAIR 2 133 98 SF 5'-0"4'-0" 5' - 0 " 4' - 6 " MAXIMUM TRAVEL DISTANCE: 300' CURRENT TRAVEL DISTANCE: 116' F.E. 95 ' - 7 " S E P A R A T I O N B E T W E E N E X I T S 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 4 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 CO M M O N P A T H O F T R A V E L : 3 8 L F CO M M O N P A T H O F T R A V E L : 3 8 L F CO M M O N P A T H O F T R A V E L : 3 8 L F CO M M O N P A T H O F T R A V E L : 3 8 L F 5' - 0 " 5' - 0 " 5' - 0 " 5'-0"5'-0"5'-0"5'-0" CO M M O N P A T H O F T R A V E L : 4 4 L F CO M M O N P A T H O F T R A V E L : 4 4 L F CO M M O N P A T H O F T R A V E L : 4 4 L F CO M M O N P A T H O F T R A V E L : 4 4 L F 5' - 0 " 5'-1"5'-0" 5' - 0 " 5' - 0 " 5' - 0 " 5' - 0 " 5' - 0 " 5'-0"5'-0" 5' - 0 " 5' - 0 " 5' - 0 " EXISTING STAIRWAY NOTES: A.MIN CLEAR WIDTH OF 44". {CBC 1011.2}** B.HEADROOM CLEARANCE OF ≥80". {CBC 1011.3}** C.RISER HEIGHTS SHALL BE 7" MAX AND 4" MIN. TREAD DEPTHS SHALL BE 11" MIN. {CBC 1011.5.2}** D.PROVIDE A FLOOR OR LANDING AT THE TOP AND BOTTOM OF EACH STAIRWAY. WIDTH AND LENGTH OF THE LANDING SHALL NOT BE LESS THAN THE WIDTH OF STAIRWAY SERVED. {CBC 1011.6} E.STAIRWAYS SHALL BE BUILT OF MATERIALS CONSISTENT WITH THE TYPE OF CONSTRUCTION. {CBC 1011.7} F.WALLS AND SOFFITS OF ENCLOSED USABLE SPACES UNDER STAIRWAYS SHALL BE PROTECTED BY 1-HR FIRE-RESISTANCE-RATED CONSTRUCTION OR THE FIRE-RESISTANCE RATING OF THE STAIRWAY, WHICHEVER IS GREATER. THE OPEN SPACE UNDER EXTERIOR STAIRWAYS SHALL NOT BE USED FOR ANY PURPOSE. {CBC 1011.7.3-4}** G.A FLIGHT OF STAIRS SHALL HAVE A VERTICAL RISE ≤12' BETWEEN FLOOR LANDINGS. {CBC 1011.8}** H.STAIRS SHALL HAVE HANDRAILS ON EACH SIDE. {CBC 1011.11} I.ONE STAIRWAY SHALL EXTEND TO THE ROOF SURFACE IN BUILDINGS >3 STORIES ABOVE GRADE PLANE. ACCESS TO THE ROOF SHALL BE PROVIDED THROUGH A PENTHOUSE. WHERE ROOF HATCH OPENING IS LOCATED WITHIN 10' OF THE ROOF EDGE, ACCESS SHALL BE PROTECTED BY GUARDS. {CBC 1011.12-13}** HANDRAILS: A. HEIGHT BETWEEN 34"-38". {CBC 1014.2}** B. EXTEND HORIZONTALLY ≥12" BEYOND THE TOP RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. {CBC 1014.6}** C. INTERMEDIATE HANDRAILS REQUIRED SUCH ALL PORTIONS OF REQUIRED WIDTH ARE WITHIN 30". {CBC 1014.9} GUARDS: A. REQUIRED ALONG OPEN-SIDED WALKING SURFACES LOCATED >30" TO THE FLOOR BELOW. {CBC 1015.2}** B. HEIGHT ≥42". {CBC 1015.3}** C. NO OPENINGS WHICH ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER FROM WALKING SURFACE TO GUARD HEIGHT. {CBC 1015.4}** D.WHERE ROOF HATCH OPENING IS WITHIN 10' OF ROOF EDGE. {CBC 1015.7}** 1018.5 AISLES IN OTHER THAN ASSEMBLY SPACES AND GROUPS B AND M IN OTHER THAN ROOMS OR SPACES USED FOR ASSEMBLY PURPOSES AND GROUP B AND M OCCUPANCIES, THE MINIMUM CLEAR AISLE CAPACITY SHALL BE DETERMINED BY SECTION 1005.1 FOR THE OCCUPANT LOAD SERVED, BUT THE WIDTH SHALL BE NOT LESS THAN THAT REQUIRED FOR CORRIDORS BY SECTION 1020.2. EXCEPTION: NONPUBLIC AISLES SERVING LESS THAN 50 PEOPLE AND NOT REQUIRED TO BE ACCESSIBLE BY CHAPTER 11B (SEE SECTION 11B-403) NEED NOT EXCEED 28 INCHES (711 MM) IN WIDTH. AL L I D E A S , C O N C E P T S , D E S I G N S , A R R A N G E M E N T S A N D P L A N S I N D I C A T E D O R R E P R E S E N T E D B Y T H I S D R A W I N G A R E O W N E D B Y A N D T H E P R O P E R T Y O F K O B R A D E S I G N A N D W E R E C R E A T E D , E V O L V E D A N D D E V E L O P E D F O R U S E O N A N D I N C O N N E C T I O N W I T H T H E S P E C I F I E D P R O J E C T . N O N E O F S U C H I D E A S , C O N C E P T S , D E S I G N S , A R R A N G E M E N T S O R P L A N S S H A L L B E U S E D B Y O R DI S C L O S E D T O A N Y P E R S O N , F I R M O R C O R P O R A T I O N F O R A N Y P U R P O S E , W H A T S O E V E R , W I T H O U T T H E W R I T T E N P E R M I S S I O N O F K O B R A D E S I G N . F I L I N G T H E S E D R A W I N G S O R S P E C I F I C A T I O N S W I T H A N Y P U B L I C A G E N C Y I S N O T P U B L I C A T I O N O F S A M E A N D N O C O P Y I N G , R E P R O D U C T I O N O R U S E T H E R E O F I S P E R M I S S I B L E W I T H O U T T H E C O N S E N T O F K O B R A D E S I G N . tw o - t i e r s t o r a g e r a c k s 35 3 5 w e s t g a r r y a v e n u e sa n t a a n a , c a 9 2 7 0 4 submittals & revisions sheet: project no: date: kdg-2024-118 04-08-2024 M A S T E R P L A N N I N G I N T E R I O R D E S I G N kobra design group inc 17151 newhope st, suite 108 fountain valley ca 92708 eml: hja@kobradesign.net mbl:714.313.6815 ca:714.962.5315 az:928.714.6909 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL NEW & EXISTING DIMENSIONS, NEW & EXISTING ROOF SLOPES, NEW & EXISTING HEIGHTS AND GENERAL EXISTING CONDITIONS THEREON BEFORE COMMENCING WORK. REPORT ANY DISCREPANCIES AND/OR POTENTIAL PROBLEMS TO THE DESIGNER AND STRUCTURAL ENGINEER PRIOR TO PROCEEDING. ALL CONSTRUCTION SHALL CONFORM TO THE CBC. A R C H I T E C T U R E S P A C E P L A N N I N G BUILDING DEPT SUBMITTAL 07.05.2024 1 plot date:2024.09.10 PLAN CHECK CORRECTIONS 09.10.2024 A1.0 egress plan: ground floor plan 20 egress/existing plan, ground floor plan (for reference only) scale 3/32"=1'-0" DENOTES MIN 44" PATH OF TRAVEL IN PUBLIC AREA. DENOTES MIN 36" PATH OF SECONDARY TRAVEL. 2A 10BC FIRE EXTINGUISHERS ARE REQUIRED WITHIN 75' OF TRAVEL FROM ANY POINT IN PUBLIC AREA. THEY MUST BE MOUNTED CONSPICUOUSLY. FINAL LOCATIONS TO BE CONFIRMED BY FIRE INSPECTOR. EMERGENCY EXIT SIGNAGE, REFER TO ELECTRICAL. F.E. NOTES: 1.SEE SHEET A0.1 FOR ADA AND DOOR CLEARANCE DETAILS. NORTH TN EGRESS/EXISTING LEGEND STAIRWAY NOTES AISLE NOTES AREA & OCCUPANT LOAD BREAKDOWN (TABLE 1004.1.2) 1 BUILDING DEPT RESUBMITTAL, DELTA-1 1, 0 0 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 70 0 G A L . WA T E R T A N K 1, 0 0 0 G A L . WA T E R T A N K 11 16 2 4 4 AL L I D E A S , C O N C E P T S , D E S I G N S , A R R A N G E M E N T S A N D P L A N S I N D I C A T E D O R R E P R E S E N T E D B Y T H I S D R A W I N G A R E O W N E D B Y A N D T H E P R O P E R T Y O F K O B R A D E S I G N A N D W E R E C R E A T E D , E V O L V E D A N D D E V E L O P E D F O R U S E O N A N D I N C O N N E C T I O N W I T H T H E S P E C I F I E D P R O J E C T . N O N E O F S U C H I D E A S , C O N C E P T S , D E S I G N S , A R R A N G E M E N T S O R P L A N S S H A L L B E U S E D B Y O R DI S C L O S E D T O A N Y P E R S O N , F I R M O R C O R P O R A T I O N F O R A N Y P U R P O S E , W H A T S O E V E R , W I T H O U T T H E W R I T T E N P E R M I S S I O N O F K O B R A D E S I G N . F I L I N G T H E S E D R A W I N G S O R S P E C I F I C A T I O N S W I T H A N Y P U B L I C A G E N C Y I S N O T P U B L I C A T I O N O F S A M E A N D N O C O P Y I N G , R E P R O D U C T I O N O R U S E T H E R E O F I S P E R M I S S I B L E W I T H O U T T H E C O N S E N T O F K O B R A D E S I G N . tw o - t i e r s t o r a g e r a c k s 35 3 5 w e s t g a r r y a v e n u e sa n t a a n a , c a 9 2 7 0 4 submittals & revisions sheet: project no: date: kdg-2024-118 04-08-2024 M A S T E R P L A N N I N G I N T E R I O R D E S I G N kobra design group inc 17151 newhope st, suite 108 fountain valley ca 92708 eml: hja@kobradesign.net mbl:714.313.6815 ca:714.962.5315 az:928.714.6909 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL NEW & EXISTING DIMENSIONS, NEW & EXISTING ROOF SLOPES, NEW & EXISTING HEIGHTS AND GENERAL EXISTING CONDITIONS THEREON BEFORE COMMENCING WORK. REPORT ANY DISCREPANCIES AND/OR POTENTIAL PROBLEMS TO THE DESIGNER AND STRUCTURAL ENGINEER PRIOR TO PROCEEDING. ALL CONSTRUCTION SHALL CONFORM TO THE CBC. A R C H I T E C T U R E S P A C E P L A N N I N G BUILDING DEPT SUBMITTAL 07.05.2024 1 plot date:2024.09.10 PLAN CHECK CORRECTIONS 09.10.2024 ST1.1 site plan/ plot plan 20 site/plot plan scale: 1" = 20'-0" NORTHTN GENERAL INFO: APN:414-213-06 LOT SQ. FT.73,185 SF LOT ACRES 1.68 TOPOGRAPHY LEVEL ZONING M1 - LIGHT INDUSTRIAL LEGAL DESCRIPTION: PARKING PROVIDED REQUIRED 9' x 18' PARKING 31 STALLS 25 STALLS (1/1,000 SF) 9' x 18' ACCESSIBLE 2 STALLS 2 STALLS (1/25 STALLS) 10' x 18' LOADING 4 STALLS 3 STALLS (1/10,000 SF) SITE PLAN NOTES FIRE HYDRANT MAP (300' RADIUS)DOT INDICATES LOCATION OF HYDRANTS NORTH TN NOTE: EXISTING PERMITTED (PC/PERMIT# 10111863) FIRE SERVICE AND BACKFLOW LOCATION WITHIN PROPERTY LINES. 1 BUILDING DEPT RESUBMITTAL, DELTA-1 AL L I D E A S , C O N C E P T S , D E S I G N S , A R R A N G E M E N T S A N D P L A N S I N D I C A T E D O R R E P R E S E N T E D B Y T H I S D R A W I N G A R E O W N E D B Y A N D T H E P R O P E R T Y O F K O B R A D E S I G N A N D W E R E C R E A T E D , E V O L V E D A N D D E V E L O P E D F O R U S E O N A N D I N C O N N E C T I O N W I T H T H E S P E C I F I E D P R O J E C T . N O N E O F S U C H I D E A S , C O N C E P T S , D E S I G N S , A R R A N G E M E N T S O R P L A N S S H A L L B E U S E D B Y O R DI S C L O S E D T O A N Y P E R S O N , F I R M O R C O R P O R A T I O N F O R A N Y P U R P O S E , W H A T S O E V E R , W I T H O U T T H E W R I T T E N P E R M I S S I O N O F K O B R A D E S I G N . F I L I N G T H E S E D R A W I N G S O R S P E C I F I C A T I O N S W I T H A N Y P U B L I C A G E N C Y I S N O T P U B L I C A T I O N O F S A M E A N D N O C O P Y I N G , R E P R O D U C T I O N O R U S E T H E R E O F I S P E R M I S S I B L E W I T H O U T T H E C O N S E N T O F K O B R A D E S I G N . tw o - t i e r s t o r a g e r a c k s 35 3 5 w e s t g a r r y a v e n u e sa n t a a n a , c a 9 2 7 0 4 submittals & revisions sheet: project no: date: kdg-2024-118 04-08-2024 M A S T E R P L A N N I N G I N T E R I O R D E S I G N kobra design group inc 17151 newhope st, suite 108 fountain valley ca 92708 eml: hja@kobradesign.net mbl:714.313.6815 ca:714.962.5315 az:928.714.6909 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL NEW & EXISTING DIMENSIONS, NEW & EXISTING ROOF SLOPES, NEW & EXISTING HEIGHTS AND GENERAL EXISTING CONDITIONS THEREON BEFORE COMMENCING WORK. REPORT ANY DISCREPANCIES AND/OR POTENTIAL PROBLEMS TO THE DESIGNER AND STRUCTURAL ENGINEER PRIOR TO PROCEEDING. ALL CONSTRUCTION SHALL CONFORM TO THE CBC. A R C H I T E C T U R E S P A C E P L A N N I N G BUILDING DEPT SUBMITTAL 07.05.2024 1 plot date:2024.09.10 PLAN CHECK CORRECTIONS 09.10.2024 TS title sheet Two-tier rack improvement plans: 3535 West Garry Avenue Santa Ana, CA 92704 Santa Ana plan check #: 101120134 vicinity map THE EXISTING USE OF THIS SPACE IS THE SAME AS THE NEW (PROPOSED) USE. THEREFORE NO CHANGE IN PARKING SPACES AND LOCATION OF THESE IS REQUIRED. parking analysis project team-contacts project information NORTH PROJECT SCOPE: ADDING TWO TIER STORAGE RACKS TO AN EXISTING BUILDING. PROPOSED PROJECT RACKS: 28 TWO TIER RACKS. PROPOSED RACK HEIGHTS: 13'-6" A.F.F. APN: 414-213-06 LEGAL DESCRIPTION: EXISTING TYPE OF USE/OCCUPANCY: F-1, S-1 PROPOSED TYPE OF USE/OCCUPANCY: F-1, S-1 TENANT IMPROVEMENT TYPE OF CONSTRUCTION: TYPE III-B FIRE SPRINKLERED: SPRINKLERED TOTAL EXISTING BUILDING AREA: TOTAL PROJECT AREA 25,798 SF TOTAL LOT AREA:73,185 SF/1.68 AC PROJECT VALUATION: $12,000 BLDG HEIGHT: 27'-0" BUILDING CODES:2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING CODE 2022 CALIFORNIA FIRE CODE 2022 CITY OF SANTA ANA MUNICIPAL CODE PROJECT SITE PROPERTY OWNER:THE COURTNEY TRUST 41 RITZ COVE DRIVE DANA POINT CA 92629 CONTACT: GEORGE COURTNEY 714.412.8156 GEORGE@COURTNEYINC.COM TENANT:ORGANIC GROWTH VENTURES INC 3535 W GARRY AVE SANTA ANA CA 92704 CONTACT: GREG GLOGOW 949.315.5340 GREG@SCMG.COM OWNER'S REP/PROJECT LEAD:FASTTRACK POWER CONTACT: BRAD KENSON 949.228.5687 BRAD@FASTRACKPOWER.COM ARCH / ENG. TEAM LEAD:KOBRA DESIGN CONTACT: HERMAN JACK AJAMIAN 17151 NEWHOPE ST, SUITE 108 FOUNTAIN VALLEY CA 92708 714.313.6815 HJA@KOBRADESIGN.NET STRUCTURAL ENGINEER:RAMIREZ STRUCTURAL INC CONTACT: JOSE RAMIREZ, PE 562.519.6045 JOSE@RAMIREZSTRUCTURAL.COM S. H A R B O R B L V D . W. GARRY AVE W. SEGERSTROM AVE. S. S U S A N S T R E E T sheet index project notes THE PROJECT SITE SHALL BE KEPT CONTINUOUSLY FENCED IN ACCORDANCE UNTIL THE PROJECT IS FINALIZED OR APPROVAL TO REMOVE THE FENCE HAS BEEN OBTAINED FROM THE CITY BUILDING DIVISION. 24-HOUR SECURITY SHALL BE PROVIDED ANY TIME THE FENCE CANNOT BE MAINTAINED INTACT. CALGREEN RECYCLING REQUIREMENT: TO COMPLY THIS PROJECT REQUIRES THE USE OF FRANCHISE HAULER. EVERY CANNABIS BUSINESS SHALL IMPLEMENT ADEQUATE VENTILATION SYSTEM AND ODOR CONTROL FILTRATION MEASURES TO PREVENT ODORS FROM INSIDE THE CANNABIS FACILITY FROM BEING DETECTED OUTSIDE THE CANNABIS FACILITY, TO INCLUDE BUILDING AND THE UNIT. A LICENSED MECHANICAL ENGINEER SHALL DESIGN THE SYSTEM THAT IS CAPABLE OF PREVENTING ODORS FROM INSIDE THE CANNABIS FACILITY FROM BEING DETECTED OUTSIDE THE CANNABIS FACILITY. THE DESIGN OF THE VENTILATION AND FILTRATION SYSTEM SHALL BE BASED ON INDUSTRY-SPECIFIC BEST CONTROL TECHNOLOGIES AND BEST MANAGEMENT PRACTICES TO EFFECTIVELY MITIGATE CANNABIS ODORS. ENVIRONMENTAL CONTROL SYSTEMS SHALL BE IMPLEMENTED TO MINIMIZE AND/OR PREVENT THE LIKELIHOOD OR MOLD AND MILDEW GROWTH AND SHALL INCLUDE A RANGE OF ENVIRONMENTAL CONTROL TECHNOLOGIES AND PRACTICES TO CONTROL HUMIDITY LEVELS, ILLUMINATION, HEATING, COOLING, AIR CIRCULATION, AND VENTILATION. THE SYSTEM SHALL BE COMPATIBLE WITH ODOR PREVENTION AND VENTILATION SYSTEMS TO PREVENT CANNABIS ODORS FROM BEING DETECTED OUTSIDE THE CULTIVATION FACILITY, WHILE STILL ALLOWING FOR THE PERMITTEE TO SUCCESSFULLY CULTIVATE. plan notes ARCHITECTURAL TS TITLE SHEET ST1.1 SITE PLAN A0.1 ACCESSIBILITY NOTES A1.0 EGRESS PLAN - GROUND FLOOR PLAN (FOR REFERENCE ONLY) STRUCTURAL S1.0 STRUCTURAL NOTES S2.0 STRUCTURAL FOUNDATION PLAN S3.0 STRUCTURAL DETAILS IS S U E D A T E REVISION BU I L D I N G D E P T 1 S T S U B M I T T A L , 07 / 0 5 / 2 0 2 4 : BU I L D I N G D E P T R E S U B M I T T A L , 09 / 1 6 / 2 0 2 4 : 1 1 BUILDING DEPT RESUBMITTAL, DELTA-1 Bldg #101120134 APPROVALS: PLNG - C. Santana BLDG - T. Le PUBLIC WORKS - Y. Soto **OCFA notes: Storage for plants only. No storage on top rack, plastic pots to be a maximum of 6 ft. with no storage above.** SPECIAL INSPECTION 1.SPECIAL INSPECTION SHALL MEET THE REQUIREMENTS OF THE 2022 CBC SECTION 1704 & 1705. 2.SPECIAL INSPECTOR SHALL: A.BE UNDER THE SUPERVISION OF A CALIFORNIA REGISTERED ENGINEER. B.OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH APPROVED DRAWINGS AND SPECIFICATIONS. B.FURNISH INSPECTION REPORTS TO THE ENGINEER AND BUILDING DEPARTMENT. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION; THEN IF NOT CORRECTED, TO THE ENGINEER AND BUILDING DEPARTMENT. C.SUBMIT TO THE ENGINEER AND BUILDING DEPARTMENT A FINAL REPORT, SIGNED BY A CALIFORNIA REGISTERED CIVIL ENGINEER, STATING THAT THE WORK WAS IN CONFORMANCE WITH THE APPROVED DRAWINGS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CBC. 3.INSPECTION NOTES: A.CONSTRUCTION INSPECTIONS LISTED ARE IN ADDITION TO THE CALLED INSPECTIONS REQUIRED BY THE 2022 CBC SECTION 110. SPECIAL INSPECTION IS NOT A SUBSTITUTE FOR INSPECTION NY A BUILDING OFFICIAL, SPECIALLY INSPECTED WORK WHICH IS INSTALLED OR COVERED WITHOUT THE APPROVAL OF THE BUILDING OFFICIAL IS SUBJECT TO REMOVAL FOR EXPOSURE. B.CONTINUOUS INSPECTION IS ALWAYS REQUIRED DURING PERFORMANCE OF THE WORK UNLESS SPECIFICALLY NOTED. C.SPECIAL INSPECTORS MUST BE CERTIFIED BY THE BUILDING DEPARTMENT TO PERFORM THE TYPES OF INSPECTIONS SPECIFIED. D.IT IS THE RESPONSIBILITY OF THE OWNER TO INFORM THE SPECIAL INSPECTOR OR INSPECTION AGENCY AT LEAST ONE WORKING DAY BEFORE PERFORMING ANY WORK THAT REQUIRED SPECIAL INSPECTION. ALL WORK PERFORMED WITHOUT REQUIRED SPECIAL INSPECTION IS SUBJECT TO REMOVAL. 1.ANCHORS, ANCHOR BOLTS, & DOWELS A.VERIFY MANUFACTURERS INSTALLATION REQUIREMENTS (AND TESTING) OF EPOXIED DOWELS IN CONCRETE AT (HOLDOWNS) (EXISTING FOOTINGS) (CONCRETE REPAIRS). B.VERIFY MANUFACTURERS INSTALLATION REQUIREMENTS OF WEDGE AND SLEEVE ANCHORS (WHERE INDICATED). SPECIAL INSPECTION REQUIRED GENERAL NOTES 1.NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS TAKE PRECEDENCE OVER THESE STANDARD STRUCTURAL NOTES. DETAILS NOTES AS "TYPICAL DETAILS" SHALL BE USED WHENEVER APPLICABLE. REFER TO SPECIFICATIONS FOR INFORMATION NOT COVERED BY THESE NOTES OR DRAWINGS. 2.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE STARTING WORK, AND THE ENGINEER/ARCHITECT SHALL BE NOTIFIED IMMEDIATELY, IN WRITING, OF ANY DISCREPANCIES. IN NO CASE SHALL DIMENSIONS BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THE STRUCTURAL DRAWINGS. 3.ALL OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE STRUCTURAL DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION, AND RESOLVED WITH, THE ENGINEER BEFORE PROCEEDING WITH ANY WORK SO INVOLVED. 4.WHERE A CONSTRUCTION DETAIL IS NOT SPECIFICALLY SHOWN OR NOTES, THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 5.THE CONTRACTOR SHALL DETERMINE THE LOCATION OF UTILITY SERVICES IN THE AREA TO BE EXCAVATED, BEFORE BEGINNING EXCAVATION. 6.NO PIPES, DUCTS, SLEEVES, CHASES, ETC. SHALL BE PLACED IN OR THROUGH SLABS, BEAMS, OR WALLS, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC. EXCEPT AS INDICATED ON THE STRUCTURAL DRAWINGS. THE CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. 7.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE 2022 CBC. 8.THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 9.RETAIN A CALIFORNIA REGISTERED CIVIL ENGINEER TO DESIGN ALL TEMPORARY BRACING, SHORING, AND SUPPORT REQUIRED DURING CONSTRUCTION. 10.INCLUDE ENGINEERING FEES, ENGINEERING DESIGN TIME AND BUILDING DEPARTMENT APPROVAL TIME IN THE COST OF PROPOSED MATERIAL ALTERNATIVES. CONTACT ENGINEER FOR FEE AMOUNT. SUBMIT MATERIAL ALTERNATIVE FOR REVIEW BEFORE CONSTRUCTION. DESIGN CRITERIA 1.VERTICAL LOADS (GRAVITY): a)DEAD LOADS: ROOF 15 PSF FLOOR 20 PSF b)LIVE LOADS (REDUCIBLE UNLESS NOTED OTHERWISE): ROOF 20 PSF FLOOR 40 PSF 2.LATERAL LOADS: a)EARTHQUAKE DESIGN DATA: V = 0.224 W (ASD) (INCLUDES RHO = 1.15 FOR MOMENT FRAME) V = 0.380 W (ASD) (INCLUDES RHO = 1.3 FOR BRACED FRAME) SEISMIC IMPORTANCE FACTOR =1 RISK CATEGORY =II MAPPED SPECTRAL RESPONSE ACCELERATIONS Ss 1.500 S1 0.560 SITE CLASS DEFAULT SPECTRAL RESPONSE COEFFICIENTS Sds 1.160 Sd1 0.820 RESPONSE MODIFICATION FACTOR PLYWOOD SHEARWALLS R 6.5 (MOMENT FRAME DIRECTION) R 4.0 (BRACED FRAME DIRECTION) SEISMIC RESPONSE COEFFICIENT Cs 0.195 (MOMENT FRAME DIRECTION) Cs 0.292 (MOMENT BRACED DIRECTION) ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE TABLE NO. 2304.10.1: FASTENING SCHEDULE CONNECTION FASTENINGS 1. BLOCKING BETWEEN CEILING JOIST, RAFTERS OR LOCATION 3-8d COMMON (2 1/2"x 0.131"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES 7/16" CROWN EACH END, TOENAIL BLOCKING BETWEEN RAFTERS OR TRUSS NOT END NAIL FACE NAIL 3-10d BOX (3"x 0.128"); OR 2-8d COMMON (2 1/2"x 0.131") EACH END, TOENAIL AT THE WALL TOP PLATE, TO RAFTER OR TRUSS TRUSSES TO TOP PLATE OR OTHER FRAMING BELOW 2-3"x 0.131" NAILS 2-3" 14 GAGE STAPLES 2-16d COMMON (3 1/2"x 0.162") 3-3"x 0.131" NAILS 3-3" 14 GAGE STAPLES 16d COMMON (3 1/2"x 0.162") @ 6" O.C. 3"x 0.131" NAILS @ 6" O.C. 3"x 14 GAGE STAPLES @ 6" O.C. FLAT BLOCKING TO TRUSS AND WEB FILLER 2. CEILING JOISTS TO TOP PLATE 3-8d COMMON (2 1/2"x 0.131"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES 7/16" CROWN 3-10d BOX (3"x 0.128"); OR EACH JOIST, TOENAIL 3. CEILING JOIST NOT ATTACHED TO PARALLEL 3-16d COMMON (3 1/2"x 0.162"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES 7/16" CROWN 4-10d BOX (3"x 0.128"); OR FACE NAILRAFTER, LAPS OVER PARTITIONS (NO THRUST) (SEE SECTION 2308.7.3.1, TABLE 2308.7.3.1) 4. CEILING JOIST ATTACHED TO PARALLEL RAFTER (HEEL JOINT)(SEE SECTION 2308.7.3.1 TABLE 2308.7.3.1)PER TABLE 2308.7.3.1 FACE NAIL 5. COLLAR TIE TO RAFTER 3-10d COMMON (3"x 0.148"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES 7/16" CROWN 4-10d BOX (3"x 0.128"); OR FACE NAIL 6. RAFTER OR ROOF TRUSS TO TOP PLATE 3-10d COMMON (3"x 0.148"); OR 4-10d BOX (3"x 0.128"); OR 4-3" 14 GAGE STAPLES 7/16" CROWN 3-16d BOX (3 1/2"x 0.135"); OR 4-3"x 0.131" NAILS; OR(SEE SECTION 2308.7.5, TABLE 2308.7.5) TOENAIL 7. ROOF RAFTERS TO RIDGE VALLEY OR HIP RAFTERS; 2-16d COMMON (3 1/2"x 0.162"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES 7/16" CROWN OR 3-10d BOX (3"x 0.128"); OR END NAIL OR ROOF RAFTER TO 2-INCH RIDGE BEAM 3-10d COMMON (3 1/2"x 0.148"); OR 4-10d BOX (3"x 0.128"); OR 4-3" 14 GAGE STAPLES, 7/16" CROWN 3-16d BOX (3 1/2"x 0.135"); OR 4-3"x 0.131" NAILS; OR TOENAIL 8. STUD TO STUD (NOT AT BRACED WALL PANELS) 16d COMMON (3 1/2"x 0.162");24" O.C. FACE NAIL 10d BOX (3"x 0.128") 3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 16" O.C. FACE NAIL 9. STUD TO STUD AND ABUTTING STUDS AT 16d COMMON (3 1/2"x 0.162"); OR 16" O.C. FACE NAIL 16d BOX (3 1/2"x 0.135"); ORINTERSECTING WALL CORNERS ( AT BRACED 3"x0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 12" O.C. FACE NAIL 12" O.C. FACE NAILWALL PANELS) 16d COMMON (3 1/2"x 0.162"); 16d BOX (3 1/2"x 0.135") 16"O.C. EA EDGE, FACE NAIL 12"O.C. EA EDGE, FACE NAIL10. BUILT-UP HEADER (2" TO 2" HEADER) 4-8d COMMON (2 1/2"x0.131"); OR 4-10d BOX (3"x0.128")TOENAIL11. CONTINUOUS HEADER TO STUD 16d COMMON (3 1/2"x 0.162");16" O.C. FACE NAIL 10d BOX (3"x 0.128"); OR 3"x 0.131" NAILS; OR 3" 14 GAGE STAPLES, 7/16" CROWN 12" O.C. FACE NAIL12. TOP PLATE TO TOP PLATE 8-16d COMMON (3 1/2"x 0.162"); OR 12-3"x 0.131" NAILS; OR 12-3" 14 GAGE STAPLES 7/16" CROWN 12-10d BOX (3"x 0.128"); OR EACH SIDE OF END JOINT, 13. TOP PLATE TO TOP PLATE, AT END JOINTS FACE NAIL (MINIMUM 24" LAP SPLICE LENGTH EACH SIDE OF END JOINT) 16d COMMON (3 1/2"x 0.162");16" O.C. FACE NAIL 16d BOX (3 1/2"x 0.135"); OR 3"x 0.131" NAILS OR 3" 14 GAGE STAPLES, 7/16" CROWN 12" O.C. FACE NAIL 14. BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) 2-16d COMMON (3 1/2"x 0.162"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES, 7/16" CROWN 3-16d BOX (3 1/2"x 0.135"); OR15. BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING AT BRACED WALL PANELS 16" O.C. FACE NAIL 4-8d COMMON (2 1/2"x 0.131"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES, 7/16" CROWN OR 4-10d BOX (3"x 0.128"); OR 16. STUD TO TOP OR BOTTOM PLATE TOENAIL 2-16d COMMON (3 1/2"x 0.162"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 3-10d BOX (3"x 0.128"); OR END NAIL 2-16d COMMON (3 1/2"x 0.162"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 3-10d BOX (3"x 0.128"); OR END NAIL17. TOP OR BOTTOM PLATE TO STUD 2-16d COMMON (3 1/2"x 0.162"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 3-10d BOX (3"x 0.128"); OR FACE NAIL18. TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS 2-8d COMMON (2 1/2"x 0.131"); OR 2-3"x 0.131" NAILS; OR 2-3" 14 GAGE STAPLES, 7/16" CROWN 2-10d BOX (3"x 0.128"); OR FACE NAIL19. 1" BRACE TO EACH STUD AND PLATE 2-8d COMMON (2 1/2"x 0.131"); OR 2-10d BOX (3"x 0.128")FACE NAIL20. 1"x6" SHEATHING TO EACH BEARING 3-8d COMMON (2 1/2"x 0.131"); OR 3-10d BOX (3"x 0.128")FACE NAIL21. 1"x8" AND WIDER SHEATHING TO EACH BEARING 3-8d COMMON (2 1/2"x 0.131"); OR FLOOR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 3-10d BOX (3"x 0.128"); OR TOENAIL22. JOIST TO SILL, TOP PLATE, OR GIRDER ROOF WALL FLOOR 8d COMMON (2 1/2"x 0.131"); OR 3"x 0.131" NAILS; OR 3" 14 GAGE STAPLES, 7/16" CROWN 10d BOX (3"x 0.128"); OR 6" O.C. TOENAIL23. RIM JOIST, BAND JOIST, OR BLOCKING TO TOP PLATE, SILL OR OTHER FRAMING BELOW 2-8d COMMON (2 1/2"x 0.131"); OR 2-10d BOX (3"x 0.128")FACE NAIL24. 1"x6" SUBFLOOR OR LESS TO EACH JOIST 2-16d COMMON (3 1/2"x 0.162")FACE NAIL25. 2" SUBFLOOR TO JOIST OR GIRDER 2-16d COMMON (3 1/2"x 0.162")EACH BEARING, FACE NAIL26. 2" PLANKS (PLANK & BEAM-FLOOR & ROOF) 20d COMMON (4"x0.192")32"O.C.,FACE NAIL AT TOP & BOT. STAGG. ON OPP. SIDES 10d BOX (3"x 0.128"); OR 3"x 0.131" NAILS; OR 3" 14 GAGE STAPLES, 7/16" CROWN 24"O.C.,FACE NAIL AT TOP & BOT. STAGG. ON OPP. SIDES 2-20d COMMON (4"x 0.192"); OR 3-3"x 0.131" NAILS; OR 3-3" 14 GAGE STAPLES, 7/16" CROWN 3-10d BOX (3"x 0.128"); OR AND:27. BUILT-UP GIRDERS AND BEAMS, 2" LUMBER LAYERS ENDS AND AT EACH SPLICE, FACE NAIL 3-16d COMMON (3 1/2"x 0.162"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES, 7/16" CROWN 4-10d BOX (3"x 0.128"); OR EACH JOIST OR RAFTER,28. LEDGER STRIP SUPPORTING JOISTS OR RAFTERS FACE NAIL 3-16d COMMON (3 1/2"x 0.162"); OR 4-3"x 0.131" NAILS; OR 4-3" 14 GAGE STAPLES, 7/16" CROWN 4-10d BOX (3"x 0.128"); OR29. JOIST TO BAND JOIST OR RIM JOIST END NAIL 2-8d COMMON (2 1/2"x 0.131"); OR 2-3"x 0.131" NAILS; OR 2-3" 14 GAGE STAPLES, 7/16" CROWN 2-10d BOX (3"x 0.128"); OR30. BRIDGING OR BLOCKING TO JOIST,EACH END, TOENAIL RAFTER OR TRUSS STRUCTURAL ABBREVATIONS A.B.ANCHOR BOLT ABV.ABOVE ADD'L ADDITIONAL ADJ.ADJACENT ALUM.ALUMINUM ALT.ALTERNATE APPRX.APPROXIMATE(LY) ARCH.ARCHITECT(TURAL) &AND @ AT BEL.BELOW B.F.BRACED FRAME BLDG.BUILDING BLK.BLOCK BLKG.BLOCKING BM.BEAM B.N. BOUNDARY NAILING BNDRY.BOUNDARY B.O.F.BOTTOM OF FOOTING BRDG.BRIDGE(ING) BRG.BEARING BTM.BOTTOM BTWN.BETWEEN CAMB.(C)CAMBER(ED) CANT.CANTILEVERED C.F.CUBIC FEET(FOOT) C.G.CENTER OF GRAVITY C.I.P.CAST IN PLACE C.J.CONSTRUCTION JOINT CL.CENTER LINE CLG.CEILING CLR.CLEAR CMU.CONC. MASONRY UNIT COL.COLUMN CONC.CONCRETE CONN.CONNECTION CONST.CONSTRUCTION CONT.CONTINUOUS CTSK.COUNTERSINK CTR.CENTER(ED) C.Y.CUBIC YARD d PENNY(NAILS) DBL.DOUBLE DEPT.DEPARTMENT D.F.DOUGLAS FIR DIA. ()DIAMETER DIAG.DIAGONAL DIAPH.DIAPHRAGM DIM.DIMENSION DN.DOWN do DITTO(REPEAT) DP (D)DEEP (DEPTH) DWG.DRAWING(S) DWL.DOWEL(S) EA.EACH E.F.EACH FACE E.J.EXPANSION JOINT EL.ELEVATION ELEC.ELECTICAL ELEV.ELEVATOR EMBD.EMBED(MENT) E.N.EDGE NAIL/SCREWS ENG.ENGINEER ES.EDGE SCREWS EQ.EQUAL EQPT.EQUIPMENT EXP.EXPANSION EXST.(E)EXISTING EXT.EXTERIOR FAB.FABRICATION FND.FOUNDATION FIN.FINISH(ED) FLG.FLANGE FLR.FLOOR F.N.FIELD(FACE)NAIL F.O.C.FACE OF CONCRETE F.O.M.FACE OF MASONRY F.O.S.FACE OF STUD F.O.W.FACE OF WALL FRM.FRAME(ING) F.S.FAR SIDE FT.(')FOOT(FEET) FTG.FOOTING GA.GAUGE GALV.GALVANIZED GB GRADE BEAM GLB GLUED LAMINATED BEAM GRD.GRADE GYPDB.GYPSUM WALLBOARD HD HOLD DOWN HDR.HEADER HGR.HANGER HORZ.(H)HORIZONTAL HSB HIGH STRENGTH HT.HEIGHT I.D.INSIDE DIAMETER I.E. INVERT ELEVATION I.F.INSIDE FACE IN.(")INCH(S) INT.INTERIOR JST.JOIST JT.JOINT K KIPS (1000) LAT.LATERAL LB(#)POUNDS L.B.LAG BOLTS LDGR LEDGER L.F.LINEAL FEET(FOOT) LG.LONG(ITUDINAL) LGTH LENGTH LLH LONG LEG HORIZ. LLV LONG LEG VERT. LT.WT.LIGTH WEIGHT MAS.MASONRY MAT'L.MATERIAL MAX.MAXIMUM M.B.MACHINE BOLT MECH.MECHANICAL MEZZ.MEZZANINE MFR.MANUFACTURER MISC.MISCELLANEOUS MIN.MINIMUM MLB MINI-LAM-BM. MTL.METAL (N)NEW NO. (#)NUMBER N.S.NEAR SIDE N.S.G.NON-SHRINK GROUT N.T.S.NOT TO SCALE O.C.ON CENTER O.D.OUTSIDE DIAMETER O.D.OUTSIDE DIAMETER O.F.OUTSIDE FACE O.H. OPPOSITE HAND OPNG.OPENING ORNT. ORIENTATE(ION) OWJ.OPEN WEB JOISTS PAR. (//)PARALLEL P/C PRECAST CONCRETE PERP. (┴)PERPENDICULAR PL.(PL)PLATE PLAM PURLAM BEAM PLY.PLYWOOD P.S.F.POUNDS PER SQUARE FOOT P.S.I.POUNDS PER SQUARE INCH P.T.PRESSURE TREATED P/T POSTTENSIONED (PRESTRESSED) QTY.QUANTITY RAD.(R)RADIUS R.C.P.REINFORCED CONCRETE PIPE REF.REFERENCE REINF.REINFORCEMENT(ING) REQ'D.REQUIRED R.F.RIGID FRAME R.O.ROUGH OPENING R.B.RIDGE BOARD SCHED.SCHEDULE SHT.SHEET SHTG.SHEATHING SIM.SIMILAR SKW.SKEW(ED) SPC.SPACE(S)(ING) SPEC.SPECIFICATION(S) SQ.SQUARE SS SELECT STRUCTURAL STD.STANDARD STGR.STAGGER(ED) STIFF.STIFFENER(S) STIR.STIRRUP(S) STL.STEEL STRUC.STRUCTURAL SUSP.SUSPENDED(TION) SYMM.SYMMETRICAL (T)TOP T & B TOP AND BOTTON TEMP.TEMPERATURE T & G TONGUE AND GROOVE THK.THICK(NESS) THRD.THREADED TMPRY.TEMPORARY T.N.TOE NAIL T.O.S.TOP OF SHEATHING T.O.W.TOP OF WALL TRANSV.TRANSVERSE T.S.TOP OF STEEL TYP.TYPICAL UBC UNIFORM BUILDING CODE U.O.N.UNLESS OTHERWISE NOTED VERT.VERTICAL VIF VERIFY IN FIELD (W)WIDE(WIDTH) w/WITH WD.WOOD W.P.WORK POINT WPJ WEAKENED PLANE JOINT W.S.WELDED STUD(S) WT WEIGHT WWF WELDED WIRE FABRIC X-STG EXTRA STRONG XX-STG DOUBLE EXTRA STRONG YD YARD a. NAILS SPACED AT 6 INCHES AT INTERMEDIATE SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE. FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAPHRAGMS AND SHEARWALLS, REFER TO SECTION 2305. NAILS FOR WALL SHEATHING ARE PERMITTED TO BE COMMON, BOX OR CASING. FOR SI: 1 INCH = 25.4 mm WOOD STRUCTURAL PANELS (WSP), SUBFLOOR, ROOF AND INTERIOR WALL SHEATHING DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER SPACING AND LOCATION TO FRAMING AND PARTICIEBOARD WALL SHEATHING TO FRAMING EDGES (INCHES) INTERMEDIATE SUPPORTS (INCHES) 6d COMMON OR DEFORMED (2"x0.113") (SUBFLOOR AND WALL) 8d BOX OR DEFORMED (2 1/2"x0.113")ROOF 6 12 6 12 2 3/8"x0.113" NAIL (SUBFLOOR AND WALL)6 12 1 3/4" 16 GAGE STAPLE, 7/16" CROWN (SUBFLOOR AND WALL)4 8 2 3/8"x0.113" NAIL (ROOF)4 8 1 3/4" 16 GAGE STAPLE, 7/16" CROWN ROOF 3 6 31. 3/8" - 1/2" 8d COMMON (2 1/2"x0.131"); OR 6d DEFORMED (2"x0.113")6 12 2" 16 GAGE STAPLE, 7/16" CROWN 4 8 10d COMMON (3"x0.148"); OR 8d DEFORMED (2 1/2"x0.131")6 12 2 3/8"x0.113" NAIL OR32. 19/32" - 3/4" 33. 7/8" - 1 1/4" OTHER EXTERIOR WALL SHEATHING (7/16" HEAD DIAMETER); OR 1 1/4" 1 1/2" GALVANIZED ROOFING NAIL 16 GAGE STAPLE WITH 7/16" OR 1" CROWN 34. 1/2" FIBERBOARD SHEATHING b 3 6 (7/16" DIAMETER HEAD); OR 1 1/2" 1 3/4" GALVANIZED ROOFING NAIL 16 GAGE STAPLE WITH 7/16" OR 1" CROWN 35. 25/32" FIBERBOARD SHEATHING b 3 6 WOOD STRUCTURAL PANELS, COMBINATION SUBFLOOR UNDERLAYMENT TO FRAMING 36. 3/4" AND LESS 6 128d COMMON (2 1/2"x0.131"); OR 6d DEFORMED (2"x0.113") 37. 7/8" - 1"6 128d COMMON (2 1/2"x0.131"); OR 8d DEFORMED (2 1/2"x0.131") 38. 1 1/8" - 1 1/4"6 1210d COMMON (3"x0.148"); OR 8d DEFORMED (2 1/2"x0.131") PANELS SIDING TO FRAMING (1 7/8"x0.106"); OR 6d 6d CORROSION-RESISTANT SIDING CORROSTION-RESISTANT CASING (2"x0.099") 39. 1/2" OR LESS 6 12 (2 3/8"x0.128"); OR 8d CORROSION- 8d CORROSION-RESISTANT SIDING RESISTANT CASING (2 1/2"x0.113") 40. 5/8"6 12 INTERIOR PANELING 4d CASING (1 1/2"x0.080"); OR 4d FINISH ( 1 1/2"x0.072")6 1241. 1/4" 6d CASING (2"x0.099"); OR 6d FINISH (PANEL SUPPORTS AT 24 INCHES)6 1242. 3/8" b. SPACING SHALL BE 6 INCHES ON CENTER ON THE EDGE AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS FOR NONSTRUCTURAL APPLICATIONS. PANEL SUPPORTS AT 16 INCHES (20 INCHES IF STRENGTH AXIS IN THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKED). C. WHERE A RAFTER IS FASTENED TO AND ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH THIS SCHEDULE AND THE CEILING JOIST IS FASTENED TO THE TOP PLATE IN ACCORDANCE WITH THIS SCHEDULE, THE NUMBER OF TOENAILS IN THE RAFTER SHALL BE PERMITTED TO BE REDUCED BY ON NAIL. TABLE NO. 2304.10.1: FASTENING SCHEDULE, CONT. COLD-FORMED STEEL FRAMING 1.DESIGN, MANUFACTURE, AND INSTALLATION OF LIGHT GAGE, COLD-FORMED STEEL JOISTS, PURLINS, AND STUDS SHALL CONFORM WITH CBC CHAPTER 22 SECTIONS 220 & 221. 2.STRUCTURAL LIGHT GAGE STUDS, TRACK, BRIDGING, AND ACCESSORIES SHALL BE AS SPECIFIED IN THE " STEEL STUD MANUFACTURERS ASSOCIATION" MANUAL (ICC# ER 3064P) OR AN ENGINEER APPROVED EQUAL AND BO FABRICATED USING THE FOLLOWING MATERIALS A.12, 14, AND 16 GAGE MEMBERS.......ASTM A570, GRADE 50 (50KSI) B.18 AND 20 GAGE MEMBERS..............ASTM A611, GRADE C (33 KSI) 3.ALL WELDING SHALL BE IN CONFORMANCE WITH AWS D1.3, "STRUCTURAL WELDING CODE -- SHEET STEEL". QUALIFICATIONS OF WELDERS SHALL BE IN ACCORDANCE WITH AWS D1.1 CHAPTER 5, PART C, "WELDER QUALIFICATION". USE E70XX ELECTRODES. 4.SEE LATEST EDITION OF THE AISI SPECIFICATIONS FOR THE :DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" FOR ALLOWABLE WELDS. 5.PROVISIONS FOR POSSIBLE VERTICAL MOVEMENT OF FLOORS AT WALLS SHALL BE BY USE OF "SLIDE CLIPS". 6.TEMPORARY BRACING SHALL BE PROVIDED AS REQUIRED UNTIL ERECTION IS COMPLETE AND SAFELY SECURES TO STRUCTURE. 7.CONNECTIONS SHALL BE DESIGNED IN ACCORDANCE WITH DETAILS PROVIDED AND CBC LOADS AND DEFLECTION CRITERIA. CALCULATIONS AND DRAWINGS SIGNED BY A CALIFORNIA REGISTERED CIVIL ENGINEER SHALL BE SUBMITTED TO AND REVIEWED BY THE ENGINEER AND BUILDING DEPARTMENT BEFORE FABRICATION. 8.ALL FLOORS, CEILING, AND ROOF JOISTS SHALL BE UNPUNCHED. 9.ALL SHEET METAL SCREWS (S.M.S) SHALL BE "KWIK PRO" SELF DRILLING, SELF TAPPING SCREWS PER ICC# ESR-2196, OR AN APPROVED EQUIVALENT. 3 5 3 5 W G A R R Y A V E ST O R A G E R A C K A N A L Y S I S 35 3 5 W G A R R Y A V E SA N T A A N A , C A 9 2 7 0 4 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @ramirezstructural www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.24-221 DATE:9/16/24 RAMIREZ STRUCTURAL INC STRUCTURAL NOTES S1.0 1.REFER TO STRUCTURAL NOTES ON SHEET S1.0 AND TYPICAL DETAILS ON SHEET S3.0. THESE NOTES AND DETAILS SHALL BE USED WHERE APPLICABLE WHETHER SPECIFICALLY REFERENCED ON PLANS OR NOT. 2.CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES WITH STRUCTURAL REQUIREMENTS INDICATED. REFER TO ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. 3.REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 4.NON-STRUCTURAL ELEMENTS IN NATURE SUCH AS DRAINS, SUMPS, EXTERIOR HARDSCAPE, MECHANICAL UNITS, ETC., ARE TO BE DESIGNED BY OTHERS. 5.STRUCTURAL WALLS ARE WALLS THAT RESIST GRAVITY, WIND, AND/OR SEISMIC LOADS. ALL EXTERIOR WOOD FRAMED WALLS ARE STRUCTURAL WALLS. WALLS OR PORTIONS NOT INDICATED ON THE STRUCTURAL DRAWINGS ARE PARTITION WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION AND EXTENT OF PARTITION WALLS. 6.FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. FIELD-CUT ENDS, NOTCHED, AND BORINGS SHALL BE FIELD-TREATED. FASTENERS IN TREATED WOOD SHALL BE APPROVED SILICON BRONZE/COPPER, STAINLESS STEEL, OR HOT-DIPPED ZINC COATED STEEL. 7.EXTREME CARE SHOULD BE TAKEN WHEN DOING FOUNDATION WORK WITH POST-TENSIONED SLABS (WHERE APPLICABLE). NO TENDONS SHALL BE DAMAGED OR CUT. NOTIFY THE ENGINEER OF RECORD PRIOR TO ANY DRILLING, CORING, SAQ-CUTTING, ETC. USE NON-DESTRUCTIVE METHODS TO LOCATE TENDONS PRIOR TO ANY WORK. 8.IF ADVERSE SOILS CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION MAY BE REQUIRED. (E) CONCRETE FOOTING, INDICATED WITH DASHED LINES SCALE: = 1'-0" N FOUNDATION PLAN 3/32" PLAN NOTES LEGEND 87654321 D B E C A 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 4 4x 4 4x 4 4x 4 4x 4 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 4 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 4 4x 4 4x 4 4x 4 4x 4 4x 8 4x 8 4x 8 4x 8 4x 4 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 4 4x 4 4x 4 4x 4 4x 4 4x 8 4x 8 4x 8 4x 8 4x 4 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 8 4x 4 4x 4 4x 4 4x 4 4x 4 4x 8 4x 8 4x 8 4x 8 4x 4 4x SINGLE BAY STORAGE RACK SIZE AT FLOOR LEVEL A S1.1 B S1.1 STRUCTURAL STORAGE RACK DOWN-AISLE ELEVATION STRUCTURAL STORAGE RACK CROSS-AISLE ELEVATION 5A S3.0 5B S3.0 TYP. TYP. 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 4x 6 3 5 3 5 W G A R R Y A V E ST O R A G E R A C K A N A L Y S I S 35 3 5 W G A R R Y A V E SA N T A A N A , C A 9 2 7 0 4 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @ramirezstructural www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.24-221 DATE:9/16/24 RAMIREZ STRUCTURAL INC FOUNDATION PLAN S2.0 134 5 500 LBS 2920 LBS 2920 LBS 13 ' - 6 " M A X H E I G H T 6' - 0 " M A X . 6' - 0 " M A X . 1' - 6 " (E) 5" SLAB-ON-GRADE f'c = 2500 PSI V.I.F. GROW GLIDE 2 9/16" x 2 3/16" - 0.078" COLUMN GROW GLIDE 3\" x 2\" - 0.06" BEAM 8'-0" MAX. 13 ' - 6 " M A X H E I G H T 3' - 1 1 " M A X . 0' - 9 " 4'-0" GROW GLIDE 0.944" x 0.944" - 0.063" BRACE 96" WIDE RACK CONFIGURATION CAN SUPPORT 2,960 LBS MAXIMUM ONLY ON LEVELS 1 & 2 ANTI-TIP TRACK (2) HLC-FPH 1/4"x2" SLEEVE ANCHOR @23 1/2" O.C. STRONG-BOLT 2 3/8" x hnom = 2.875" @23 1/2" O.C. ICC-ES ESR-3037 OR EQUIVALENT STORAGE RACKS ARE PREFABRICATED & ARE TO BE FIELD ASSEMBLEDONLY - NO FIELD WELDING GROW GLIDE 3 1/2" x 2 1/2" - 0.06" BEAM GROW GLIDE 2 9/16" x 2 3/16" - 0.078" COLUMN BEAM TO COLUMN CONNECTION ACCORDING TO MANUFACTURER 3 S3.0 1 S3.0 A S3.0 B S3.0 TYPICAL ELEVATION TYPICAL SECTION (E) SLAB-ON-GRADE A S3.0 B S3.0 SEE 4/S3.0 V TRACK PER MANUFACTURE 3 5 3 5 W G A R R Y A V E ST O R A G E R A C K A N A L Y S I S 35 3 5 W G A R R Y A V E SA N T A A N A , C A 9 2 7 0 4 JOSE RAMIREZ, PE jose@ramirezstructural.com (562) 519-6045 ig: @ramirezstructural www.ramirezstructural.com REVISION DESCRIPTION DATE A B C PROJECT NO.24-221 DATE:9/16/24 RAMIREZ STRUCTURAL INC TYPICAL DETAILS S3.0 jose@ramirezstructural.com (562) 519-6045 ENGINEERED BY: JOSE RAMIREZ, PE CONTACT: STRUCTURAL CALCULATIONS FOR 3535 W GARRY AVE STORAGE RACK ANALYSIS 3535 W GARRY AVE SANTA ANA, CA 92704 jose@ramirezstructural.com (562) 519-6045 DESIGN CRITERIA 1. SOIL BEARING PRESSURE: 1500 PSF 2. FOOTING MINIMUM BEARING DEPTH: 24 IN 3. CONCRETE MIN. COMPRESSIVE STRENGTH: 2500 PSI 4. REINFORCING SHALL CON FORM TO: ASTM 615, GRADE 60 5. ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FIR. a. LIGHT FRAMING (CONSTRUCTION) b. JOIST &PLANKS (No .2) c. BEAMS & STRINGERS (No.1) d. POSTS & TIMBERS (No.1) 6. PLYWOOD SHALL CONFORM TO: PS 1-95, STRUCTURAL 1 7. ALL MATERIALS & WORKMANSHIP TO CONFORM TO 2022 CALIFORNIA BUILDING CODE. ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 1/29 jose@ramirezstructural.com (562) 519-6045 DESIGN LOADS EXTERIOR WALLS 7/8" stucco 10 psf 1/2" plywood 1.5 psf 2x6 studs at 16" o.c.1.5 psf 1/2" gyp board 2.5 psf MEP + MISC.0.5 psf D = 16 psf PARTITION WALLS Drywall (2-sides)5.0 psf 2x4 studs 1.5 psf MEP + MISC.1.5 psf D = 8 psf ROOF LOADS Composite shingles 3.0 psf Re-roofing 2.0 psf 1/2" plywood 1.5 psf Rafters 3.0 psf Beams/Headers 1.0 psf MEP + MISC.1.0 psf Insulation 0.5 psf Ceiling 3.0 psf Solar panel.0.0 psf D =15 psf Lr =20 psf REDUCIBLE ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 2/29 jose@ramirezstructural.com (562) 519-6045 8 7 6 5 4 3 2 1 D BEC A SC A L E : = 1 ' - 0 " RA C K S P L A N NA 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x6 4x6 4x6 4x6 4x6 4x6 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x6 4x6 4x6 4x6 4x6 4x6 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x6 4x6 4x6 4x6 4x6 4x6 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x6 4x6 4x6 4x6 4x6 4x6 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 4x8 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 3/29 jose@ramirezstructural.com (562) 519-6045 50 0 L B S 29 2 0 L B S 29 2 0 L B S 13'-6" MAX HEIGHT 6'-0" MAX.6'-0" MAX.1'-6" (E ) 5 " S L A B - O N - G R A D E f' c = 2 5 0 0 P S I V. I . F . GR O W G L I D E 2 9 / 1 6 " x 2 3 / 1 6 " - 0 . 0 7 8 " CO L U M N GR O W G L I D E 3 \ " x 2 \ " - 0 . 0 6 " BE A M 8' - 0 " MA X . 13'-6" MAX HEIGHT 3'-11" MAX.0'-9" 4' - 0 " GR O W G L I D E 0 . 9 4 4 " x 0 . 9 4 4 " - 0 . 0 6 3 " BR A C E 96 " W I D E R A C K C O N F I G U R A T I O N CA N S U P P O R T 2 , 9 6 0 L B S M A X I M U M ON L Y O N L E V E L S 1 & 2 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 4/29 jose@ramirezstructural.com (562) 519-6045 ASCE Hazards Report Address: 3535 W Garry Ave Santa Ana, California 92704 Standard:ASCE/SEI 7-22 Latitude:33.706047 Risk Category:II Longitude:-117.916635 Soil Class:Default Elevation:40.5138478023486 ft (NAVD 88) Page 1 of 4https://ascehazardtool.org/Mon Apr 29 2024 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 5/29 jose@ramirezstructural.com (562) 519-6045 PGA M : 0.67 SMS : 1.73 SM1 : 1.23 SDS : 1.16 SD1 : 0.82 T L : 8 SS : 1.5 S1 : 0.56 VS30 : 260 Seismic Design Category: D Multi-Period Design Spectrum S (g) vs T(s)a Multi-Period MCE SpectrumR S (g) vs T(s)a Two-Period Design Spectrum S (g) vs T(s)a Two-Period MCE SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum Vertical ground motion data has not yet been made available by USGS. MCE Vertical Response SpectrumR Vertical ground motion data has not yet been made available by USGS. Seismic DefaultSite Soil Class: Results: Page 2 of 4https://ascehazardtool.org/Mon Apr 29 2024 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 6/29 jose@ramirezstructural.com (562) 519-6045 Data Accessed: Mon Apr 29 2024 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-22 and ASCE/SEI 7-22 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-22 Ch. 21 are available from USGS. Page 3 of 4https://ascehazardtool.org/Mon Apr 29 2024 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 7/29 jose@ramirezstructural.com (562) 519-6045 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 4 of 4https://ascehazardtool.org/Mon Apr 29 2024 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 8/29 jose@ramirezstructural.com (562) 519-6045 TRANSVERSE BRACED FRAME STEEL | Q235A | Fy = 30 ksi LONGITUDINAL FRAME BEAM & CONNECTION STEEL | ASTM A570 GR.50 | Fy = 50 ksi ALL OTHER STEEL | ASTM A36 GR.36 | Fy = 36 ksi ANCHOR BOLTS SHALL BE INSTALLED ACCORDING TO ICC-ES EVALUATION REPORT STORAGE RACKS ARE PREFABRICATED AND ARE TO BE FIELD ASSEMBLED ONLY | NO FIELD WELDING STRUCTURAL STORAGE RACK SYSTEM ANALYSIS INTENDS TO DETERMINE COMPLIANCE WITH GOVERNING BUILDING CODES WITH RESPECT TO STATIC & SEISMIC FORCES BEAM ANALYSIS | BRACE ANALYSIS | PUNCTURE 0.34 OK BENDING DESIGN OK 0.12 OK 0 0 PRODUCT LOAD (lbs) 18 90 162 8th 9th 10th STORAGE HEIGHT (in) 0 0 0 STORAGE LEVEL 1st 2nd 3rd 4th 5th SCOPE OF WORK 0 STRUCTURAL REFERENCE CODE 2021 INTERNATIONAL BUILDING CODE (IBC) | SECTION 2209 2022 CALIFORNIA BUILDING CODE (CBC) | SECTION 2209 0 2920 2920 500 0 6th 0 0 0 0 STRUCTURAL STORAGE RACK ANALYSIS INPUT DESIGN OK DESIGN OK COLUMN ANALYSIS | 0.78 OK INPUT DESIGN OKSTRESS I INPUT ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 9/29 jose@ramirezstructural.com (562) 519-6045 3LEVELS | ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 10/29 jose@ramirezstructural.com (562) 519-6045 LATITUDE | DEGREES RISK CATEGORY | ASCE T1.5-1 | LONGITUDE | DEGREES SITE CLASS | ANSI MH16.1 T7.4-3 | IMPORTANCE FACTOR | ANSI MH16.1 7.4.2.2 |SEISMIC DESIGN CATEGORY | ANSI MH16.1 7.4.9 | Fa == Fa * Ss = Fv = =* == Ss = = Fv * S1 = 1 ==2/3 * == BRACED FRAME | R = 4.00 MOMENT FRAME | R = 6.00 SEISMIC RESPONSE COEFFICIENT | Cs Cs = SDS/R | ANSI MH16.1 7.4.6 MINIMUM LIMIT | Cs MIN I = 0.010 MOMENT FRAME | /CsMIN II = 0.044 * SDS =* CsMIN II = COMPARE LIMITS CsMIN III = 0.50 * S1/R BRACED FRAME | ≤BRACED FRAME | CsMIN III = */ CsMIN III = MOMENT FRAME | ≤MOMENT FRAME | CsMIN III = */ CsMIN III = MOMENT FRAME | SEISMIC WEIGHT | Ws Ws = DL + 0.67 * PL | ANSI MH16.1 7.4.2.2 TOTAL PRODUCT LOAD (lbs) | TOTAL DEAD LOAD (lbs) = 3% PL | Ws (k) = DL (lbs) = PL (lbs) = Ws (k) = CASE II | WEIGHT OF RACK + HIGHEST STORAGE LEVEL ONLY AT 100% RATED LOAD CAPACITY Ws (k) = 0.044 1.17 0.051 IF S1 ≥ 0.6g | 0.50 0.49 Cs = Cs = 1.17 6.00 0.292 0.195 0.051 0.292 1.33 0.89 0.53 4.44 Cs = 0.195 6340 190 190 4248 0.051 0.195 4.00 0.50 0.49 6.00 N/A N/A 1.16 0.56 Cs = Cs = -117.916635 DEFAULT 1.00 D 1.20 2.72 1.75 1.75 1.17 SEISMIC ANALYSIS 33.706047 II SMS SDS SMS SM1 SD1 SM1 3.04 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 11/29 jose@ramirezstructural.com (562) 519-6045 NOTIONAL LOADS Vn = 0.005 * α * Yi | ANSI MH16.1 7.2.4 DS Ni | NOTIONAL LOAD APPLIED AT STORAGE LEVEL β = 0.70 | SEISMIC PRODUCT LOAD COEFFICIENT α | SECOND-ORDER LOAD AMPLIFICATION FACTOR (LRFD = 1.00) Yi | FACTORED GRAVITY LOAD APPLIED AT STORAGE LEVEL +*= NOTIONAL LOADS ONLY APPLIED DOWN-AISLE β = -3 =*=*** 10 =*== SEISMIC BASE SHEAR Vs = Cs * Ie * Ws | ANSI MH16.1 7.4.2.2 SEISMIC OVERTURNING CROSS-AISLE CASE I | WEIGHT OF RACK + EVERY STORAGE LEVEL AT 67% RATED LOAD CAPACITY V (k) =** V (k) = V (k) =** V (k) = SEISMIC CROSS-AISLE SEISMIC DOWN-AISLE V (k) =**Vs (k) =** V (k) =Vs (k) = Vn (k) = V (k) = BRACED FRAME |htotal =in MOMENT FRAME |htotal =in STORAGE RACK SHALL BE SEPARATED FROM THE BUILDING STRUCTURE AND ANY ATTACHED PERMANENT COMPONENTS OR ELEMENTS BY A DISTANCE NOT LESS THAN THOSE SHOWED ABOVE, ACCORDING TO EACH DIRECTION 1.20 0.20 1.17 1.434 1.004 Vn = 0.005 1.00 1.00 4.44 0.864 0.033 0.887 0.292 1.00 0.53 0.153 0.292 1.00 4.44 0.897 0.02 3.24 0.05 8.10 0.292 1.00 3.04 PL (lbs) 0.195 1.004 6362 1.296 6340 DL (lbs)1.434 273190 6635 Vn (k) 0.033 SEISMIC (LRFD) LOAD COMBINATION | ANSI MH16.1 7.1.3 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 12/29 jose@ramirezstructural.com (562) 519-6045 VERTICAL DISTRIBUTION OF SEISMIC FORCES | ANSI MH16.1 7.4.12 SEISMIC OVERTURNING CASE II | WEIGHT OF RACK + HIGHEST STORAGE LEVEL ONLY AT 100% RATED LOAD CAPACITY SEISMIC CROSS-AISLE SEISMIC DOWN-AISLE 1st 3rd 4th 5th 7th 8th 9th Σ i i Σ 0.0000.00 STORAGE LEVEL FORCE (k) 0.112 0.562 0.212 0.000 0.00 0.00 0.00 195.04 wihi/Σwihi 0.127 0.634 0.239 0.000 0.000 wihi 24.74 123.68 46.63 0.000 0.000 0.00 0.00 0.00 0.00 0.887 WEIGHT (lbs) 1374 1374 288 63 63 63 63 63 63 63 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.00 0.00 0.00 0.00 STORAGE LEVEL STORAGE HEIGHT FROM BASE (in) 18.00 90.00 162.00 1st 3rd 7th 9th 10th Σ i i 63 63 63 0.00 0.00 0.00 STORAGE LEVEL FORCE (k) 0.002 0.012 0.139 0.000 0.000 0.000 0.080 0.904 0.000 0.000 0.000 wihi/Σwihi 0.016 0.000 0.000 0.000 0.000 0.153 5.71 64.54 0.00 0.00 0.000 0.00 71.39 0.000 0.000 0.000 0.00 0.00 0.00 0.00 0.00 STORAGE LEVEL STORAGE HEIGHT FROM BASE (in) 18.00 WEIGHT (lbs) 63 63 398 63 63 63 90.00 162.00 0.00 0.00 0.00 63 wihi 1.14 1st 2nd 3rd 4th 5th 7th 8th 9th 10th Σ i i Σ 0.000 1.296 0.00 0.00 0.00 0.000 0.000 282.68 wihi/Σwihi 0.129 0.643 0.228 0.000 0.000 0.000 0.000 0.0000.00 0.000 0.000 STORAGE LEVEL FORCE (k) 0.167 0.833 0.296 0.000 0.000 0.000 0.000 63 63 63 0.00 0.00 0.00 STORAGE LEVEL STORAGE HEIGHT FROM BASE (in) 18.00 90.00 162.00 630.00 0.00 0.00 wihi 36.36 181.78 64.54 0.00 WEIGHT (lbs) 2020 2020 398 63 0.00 0.00 0.00 63 63 1st 2nd 3rd 4th 5th 6th 7th 8th 9th 10th Σ i i Σ282.68 0.000 0.000 0.00 0.000 0.00 0.000 0.00 0.000 0.000 0.00 0.000 0.000 0.897 STORAGE LEVEL FORCE (k) 0.115 0.577 0.205 0.000 0.000 0.000 0.000 0.000 0.000 0.129 2020 181.78 0.643 398 64.54 0.228 0.00 0.00 0.00 0.00 WEIGHT (lbs)wihi 2020 36.36 63 0.00 18.00 90.00 162.00 0.00 0.00 0.00 63 0.00 63 0.00 63 63 63 63 wihi/Σwihi STORAGE LEVEL STORAGE HEIGHT FROM BASE (in) ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 13/29 jose@ramirezstructural.com (562) 519-6045 SEISMIC FORCES | LOAD & RESISTANCE FACTOR DESIGN (LRFD)= DS -*= SEISMIC LOAD | 1.20 + 0.20SDS +*= β = 1.00 | SEISMIC UPLIFT β β = 0.70 | SEISMIC LOAD SEISMIC OVERTURNING CASE I | WEIGHT OF RACK + EVERY STORAGE LEVEL AT 67% RATED LOAD CAPACITY | CROSS-AISLE k *in *k *in * k-in k-in k *in * k-in k-in k-in (-) /in (++) /in TENSION (k) |COMPRESSION (k) | TENSION (k) | COMPRESSION (k) | CASE II | WEIGHT OF RACK + HIGHEST STORAGE LEVEL ONLY AT 100% RATED LOAD CAPACITY | CROSS-AISLE k *in *k *in * k-in k-in k *in * k-in k-in k-in (-) /in (++) /in48.0030.69 12.04 E w/ p 0.69 24.00 0.6664 0.19 w/o p 0.33 w/o p 30.69 w/o p 23.61 w/o p SHEAR (k) | 0.08 24.00 1.4336 11.04 6.54 PL 0.50 24.00 1.0035 4.08 SHEAR (k) | SEISMIC UPLIFT SEISMIC LOAD w/o p 0.44 PL 24.00 0.00004.25 102.31 E w/ p 113.05 w/o p 48.00 0.88 86.96 70.98 48.00 6.54 102.31 w/ p w/ p 4.62 86.96 86.96 0.19 6.5470.98 1.0035 4.44 1.20 0.20 1.168 1.4336 DL + PL DL 24.00 0.0000 24.00 0.0000 SDS 1.168 ANSI MH16.1 | 7.1.3 11.04 48.00 30.69 6.54 12.04 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 14/29 jose@ramirezstructural.com (562) 519-6045 SEISMIC CROSS-AISLE k *in *k *in * k-in k-in k *in * k-in k-in k-in (-) /in (++) /in TENSION (k) |COMPRESSION (k) | TENSION (k) | COMPRESSION (k) |w/o p 0.45 w/o p 5.94 w/o p SHEAR (k) | 0.65 125.93 104.44 48.00 125.93 6.54 152.70 DL + PL DL 6.53 24.00 0.6664 0.19 24.00 1.4336 w/ p 1.23 w/ p 6.73 48.00 104.44 6.54 PL 6.34 24.00 1.0035 152.70 E w/ p 163.71 w/o p 125.93 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 15/29 jose@ramirezstructural.com (562) 519-6045 BEAM MODEL: = FLANGE EFFECTIVE WIDTH (in)= w = C - 2t - 2r = w =- 2 *- 2 *= w =in = = w/t =JOINT SPRING CONSTANT | F = Fy (ksi)= f = Fy 2 2 2 Fu (ksi)= Y1 (in)= λ 2 2 2 Y2 (in)= Y3 (in)= µ = E/(2G)-1 =/ (2 *) - 1 Ycg (in)= 4 =3 = 2/(12-(1-µ2))))k = 4 | STIFFENED ELEMENTS SUPPORTED BY WEB E (ksi)= CONSTANT =G (ksi)= λ = CONSTANT/√k * (w/t) * √(Fy/E) λ =/ √4 ** √(/) λ =(1 -) / FLANGE REDUCTION FACTOR | f1 (COMPRESSION) = Fy * (Y3/Y2) =*/= f2 (TENSION) = Fy * (Y1/Y2) =*/= Ψ = |f2/f1|= |/| = Ψ 3 + 2(1 + Ψ)= 4 + 2( 1 +3 + 2( 1 +) k = w =- 2 *- 2 *w/t =/ f = f1 Fcr = (kπ E/(12-(1-µ)) * (t/w)) λ = √(f1/Fcr) = √(f1/((kπ2E/(12-(1-µ2))) * (t/w)2)) CONSTANT = λ = CONSTANT/√k * (w/t) * √(f1/E) λ =/ √() ** √(/) λ =(1 -) / BOTTOM FLANGE WIDTH | B (in) 2.000 TOP FLANGE WIDTH | C (in)1.350 BEAM THICKNESS | t (in)0.060 FILLET RADIUS | r (in)0.06 BEAM ANALYSIS COMPRESSION FLANGE | LOCAL BUCKLING [AISI S100-16 APPX. 1.1]BEAM SECTION PROPERTIES WEB DEPTH | A (in)3.500 1.350 0.060 0.06 1.110 18.50 29500 11300 1.800 29500 11300 100 50 65 1.680 1.700 1.580 1.7 49.41 49.41 46.47 1.063 1.063 1.063 WEB | LOCAL BUCKLING [AISI S100-16 APPX. 1.1.2] 50 1.58 1.7 46.47 0.22 / 0.400 0.400 N/A 1.050 1.050 18.50 50.00 29500 0.400 λ ≤ 0.673 NO REDUCTION REQUIRED | FLANGE IS FULLY EFFECTIVE 0.22 / 0.447 0.4470.447 λ 25.69 54.33 46.47 295001.050 25.69 3.500 0.060 0.06 3.260 0.060 50 1.68 1.050 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 16/29 jose@ramirezstructural.com (562) 519-6045 3 FLANGE | MOMENT OF INERTIA REDUCTION | * = 2 WEB |SECTION MODULUS REDUCTION |* = 4 3 A (in) = 4 3 Ae (in) = 2)= = (π/2) * (r + t/2) FLANGE EFFECTIVE WIDTH (in) =* (+/ 2 )w =in = = = = m = 0.192(Fuv/Fyv) - 0.068 = * (/) -= Bc = 2 - 1.79 Bc = * (/) -* (/2 - Bc = m =*/ (/) Fyc = ksi Fya-top =*+ ( 1 -) * Fya-top =ksi ≤ksi Fya-bot = Fya-top * Ycg/ (A - Ycg) Fya-bot =*/ (-) Fya-bot =ksi ≤ksi Cb = 2 * CCSA/(Lflange-bot + 2 * CCSA)= 2 */ (+ 2 *)= Fy-bot = Cb * Fyc + (1 - Cb) * Fy Fy-bot = *+ ( 1 -) * Fya-bot =ksi ≤ksi Fya-top =ksi EFFECTIVE SECTION PROPERTIES | REDUCTION FACTOR Fuv/Fyv ≥ 1.20 r/t ≤ 7.00 COLD WORK OF FORMING INCREASE ALLOWED CCSA CCSA (π/2) 0.06 0.060 1.110 1.000 1.000 1.000 1.000 UNREDUCED |1.105 0.595 3.500 REDUCED |1.105 0.595 3.500 0.1816 1.62 50 0.06 0.060 81.14 3.69 65 50 0.819 65 50 1.79 1.62 CCSA 0.141 0.192 65 50 0.068 0.1816 59.64 65.00 ALLOWABLE TENSION STRESS | BOTTOM FLANGE 0.141 1.760 0.2030 81.14 0.2030 50 56.32 65.00 56.32 1.8 3.500 1.8 0.141 0.1384 0.1384 81.14 0.1384 50 54.31 65.00 56.32 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 17/29 jose@ramirezstructural.com (562) 519-6045 LOAD & RESISTANCE FACTORED DESIGN (LRFD) COMBINATION [2021 ANSI MH16.1 7.1.3] |1.20D + 1.40P + 1.40I DEAD LOAD (D) | 3% PRODUCT LOAD (P)Ω = 1.20 * 0.03 + 1.40 + 1.40 * 0.25 IMPACT LOAD (I) | 25% PRODUCT LOAD (P)Ω = MCENTER = φMn = Ω * WL/8 * rm rm = 1 - 2FL/(6EIb + 3FL) m =1 -2 ** 6 **+ 3 ** rm = φMn = φ * Fya * Sx =**=k-in φMn = Ω * WL/8 * rm W = φMn * 8 * 2 BEAMS/Ω * L * rm W =*8 * 2 *W =lbs | PER BEAM PAIR ** = =/ = rd = 1 - 4FL/(10EIb + 5FL) d =1 -4 ** 10 **+ 5 ** rd = 3/384EIb ∆MAX = ∆ss * rD MAX 3 * d 5 *3 * Wu =lbs STATIC STRESS Wa =lbs 0.91 0.95 56.32 0.595 31.84 ALLOWABLE BENDING CAPACITY | BEAM PAIR [2021 ANSI MH16.1 C9.2] 1.786 29500 1.105 100 96.00 ∆MAXa 0.533 29500 1.105 100 96.00 0.90 1.786 96.00 0.91 ALLOWABLE DEFLECTION CAPACITY | BEAM PAIR [2021 ANSI MH16.1 C9.2] ∆MAXa L/180 96.00 180 2920 0.90 OK 3249 DESIGN OK 96.00 0.90 ALLOWABLE CAPACITY | BEAM PAIR ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 18/29 jose@ramirezstructural.com (562) 519-6045 COLUMN MODEL: = =*/= == =*/= == = 2 2 2 (E2.2-4) 2 2 2 Fy (ksi)= = ro =4 = 2 Iy (in )=β 2 β 3 = β =3 = x (in)= Kt =Lt =ry (in)= o (in )= σ 2 2 (E2.2-6)4 = 2 Jx (in)= =2 */=Cw (in6)= E (ksi)= σ 2 2 2 G (ksi)= σ 2 **)(E2.2-5) *2 *2 σt = 2 Fcre1 = π2E/(KL/rMAX)2 =2 */(E2.1-1) Fcre2 = (1/(2β))(σex + σt - √((σex + σt)2 - 4βσexσt)) (E2.2-1) 2 =*(+-√((+) *-** *) =ksi =ksi MINIMUM GOVERNS λc = √(Fy/Fcre)λc = √ (/) λc = λ λ 2 Fn1 = 0.658λc * Fy Fn2 = (0.877/λc2)Fy 2 2 =*=(/)* =ksi =ksi 0.80 46.00 COLUMN AREA | A (in2)0.875 46.00 33 COLUMN SECTION PROPERTIES COLUMN WIDTH | bx (in)2.560 COLUMN DEPTH | dy (in)2.188 COLUMN THICKNESS | t (in)0.078 COLUMN ANALYSIS 29500 11300 0.000 KyLy/ry KxLx/rx 1.70 1.00 67.00 46.00 0.983 0.872 115.87 KL/rMAX 115.87 2.514 0.273 0.669 0.481 0.872 67.000 67.00 1 21.69 Fcre2 2.00 0.273 (0.80 46.00) σex 21.686 39.710 Fcre1 29500 115.87 σex 29500 115.87 0.875 2.514 33 15.03 1.488 1 0.658 1.488 Fn1 13.18 2 0.877 1.488 33 Fn2 N/A 4.00 0.273 21.686 39.710 Fcre2 15.03 Fcre 15.03 TORSIONAL | FLEXURAL-TORSIONAL BUCKLING [AISI S100-16 E2] CROSS-AISLE UNBRACED LENGTH | Lx (in) DOWN-AISLE UNBRACED LENGTH | Ly (in) ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 19/29 jose@ramirezstructural.com (562) 519-6045 =ksi =2 Pa = φPn Pno = Fy * Ae =*Pao = φPno =* =k =k Fcre1 = (CbroA√(σexσet))/Sx Cb = 1.00 (F2.1.1-1) =**√ (*) / =ksi Fcre2 = (Cs*A*σex)/(CTF*Sx) * [Jx + Cs√(Jx2 + ro2(σt/σex))] (F2.1.2-1) 2 2 =***[-√(+()) =ksi Fcre3 = Cb*π2E/Sx(KyLy)2 (F2.1.1-6) 2 =*2 */ (* (*) ) =ksi IF Fcre ≥ 2.78Fy (F2.1-3) IF 2.78Fy > Fcre > 0.56Fy (F2.1-4) Fn = Fy Fn = (10Fy/9)(1-(10Fy/36Fcre)) =ksi Fn = Fcre =ksi =ksi =2 Mnx = Fn * Sx =*=k-in Mny = Fn * Sy =*=k-in Max = φMnx =*k-in φ 2 Pex = π EIx/(KxLx)=2 **/ (*) =k 2Pey = π EIy/(KyLy)=π **/(*) =k Pao 0.85 23.05 Pao 19.59 LATERAL TORSIONAL BUCKLING [AISI S100-16 F2] Pno 33 0.692 Pno 23.05 Fn 13.18 Ae 0.692 Fcre1 1.00 2.514 Fcre2 64.83 Fcre3 1.00 29500 0.523 1.00 0.5231.00 *21.686 0.875 21.686 39.710 0.523 Fcre1 123.42 2 -1.00 0.875 21.686 0.90 14.93 Fn2 31.721 Fn 31.72 Se 0.471 46.00 Fcre3 302.79 Fn1 N/A 3 N/A Fn2 10.00 33 1.00 9.00 10.00 67.00 Pex 15.014 Pex 29500 0.669 1.70 Mnx Mny 31.72 31.72 0.471 0.481 14.931 15.258 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 20/29 jose@ramirezstructural.com (562) 519-6045 DEMAND | LOAD & RESISTANCE FACTOR DESIGN LOAD COMBINATIONS | ANSI MH16.1 7.1.3 =k 2 | 1.40D + 1.20P Pu =k 5 | (1.2 + 0.2SDS)D + (1.2 + 0.2SDS)βP + pE Pu =k 5 | (1.2 + 0.2SDS)D + (1.2 + 0.2SDS)Βp Pu =k STATIC STRESS =k STATIC STRESS =k COMBINED STRESS I | ANSI-AISI S100-16 H1.2 | DOWN AISLE IF Pu/Pa ≤ 0.15 Pu/Pao + Mu/Max + 1/May COMBINED STRESS II | ANSI-AISI S100-16 H1.2 αx = 1 - 0.85 * (/) = αy = 1 - 0.85 * (/) = IF Pu/Pa > 0.15 αi = 1 - 0.85 * (Pu/Pei) α α ** STRESS III | CROSS-AISLE CROSS-AISLE | Pu =k =k 6.73SEISMIC LOAD | CROSS-AISLE SEISMIC LOAD | DOWN-AISLE 3.32 Pust 4.55 0.59 OK Pa 7.75 PL 3.17 4.55 13.438 13.732 13.438 13.73219.592 6.73 Pao 19.59 0.34 OKSTRESS III 3.317 3.317 15.014 72.376 0.812 0.961 13.438 0.812 13.73219.592 0.812 DESIGN OK ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 21/29 jose@ramirezstructural.com (562) 519-6045 BRACE MODEL: = =*/= = =*/= =Fy (ksi)= Fu (ksi)= 2 2 2 (E2.2-4)4 = 2 2 2 Iy (in )=3 = ro =3 = 2 rx (in)= β 2 β =1 -(/)(E2.2-3)ry (in)= β =xo (in3)= 4 = Kt =Lt =Jx (in)= w (in )= σ 2 2 (E2.2-6)E (ksi)= 2 G (ksi)= =2 */= σ 2 2 2 σ 2 **)(E2.2-5) *2 *2 σt = Fcre1 = π2E/(KL/rMAX)2 =2 */(E2.1-1) Fcre2 = (1/(2β))(σex + σt - √((σex + σt)2 - 4βσexσt)) (E2.2-1) 2 =*(+-√((+) *-** *) =ksi =ksi MINIMUM GOVERNS λc = √(Fy/Fcre)λc = √ (/) λc = λ λ 2 Fn1 = 0.658λc * Fy Fn2 = (0.877/λc2)Fy 2 2 =*=(/)* =ksi =ksi BRACE ANALYSIS TORSIONAL | FLEXURAL-TORSIONAL BUCKLING [AISI S100-16 E2]BRACE SECTION PROPERTIES 0.000 0.063 0.198 63.78UNBRACED LENGTH | L (in) BRACE THICKNESS | t (in) BRACE AREA | A (in2) 0.000 29500 KxL/rx 1.00 63.78 0.355 179.66 KyL/ry 1.00 63.78 0.355 KL/rMAX 179.66 0.502 1.000 33 42 0.027 0.027 0.056 0.198 0.502 (0.80 63.78) 9962.757 Fcre1 29500 179.66 0.80 63.78 σex 29500 179.66 σex 9.020 Fn1 N/A Fn2 7.91 9.020 9962.757 Fcre2 9.02 Fcre 9.02 33 9.02 1.913 1 9.02 Fcre2 1.00 9.020 9962.757 9.020 9962.757 2.00 1.000 4.00 1.000 1.913 1 0.658 33 Fn2 0.877 1.913 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 22/29 jose@ramirezstructural.com (562) 519-6045 =ksi =2 Pa = φPn DEMAND | LOAD & RESISTANCE FACTOR DESIGN LOAD COMBINATIONS | ANSI MH16.1 7.6 Pu =k 1.50% MAXIMUM LOADING OF COLUMN Pa =k1.33 0.13 DESIGN OK Fn 7.91 A 0.198 ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 23/29 jose@ramirezstructural.com (562) 519-6045 === MINIMUM GOVERNS =2 Fpunct1 = (4/3 + 8/3β) + 0.6 * √f'c Fpunct =ksi =psi =Fpunct2 = 2.66 * 0.60 * √f'c Pa = Fpunct * Apunct =* 2/6 2 =Sslab = = =Sslab =3 2 = 5.00 * 0.60 * √f'c Ma = Fba * Sslab =lb-in Fba Ma 625 X (in)3.82 Asoil (in2)2 2 1500 Asoil (in2) Lsoil (in)21.07 6.00 4.17 0.08 Pa (k) 0.080 168.74 PUNCHING SHEAR | PUNCTURE Apunct 168.74 β 0.80 140 SLAB ANALYSIS ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 24/29 jose@ramirezstructural.com (562) 519-6045 Company:RAMIREZ STRUCTURAL Date:2/17/2023 Engineer:JOSE RAMIREZ Page:1/5 Project:24-221 Address:3535 W Garry Ave Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2404.1 1.Project information Project description: Location: Fastening description: Comment: 2. Input Data & Anchor Parameters General Design method:ACI 318-19 Units: Imperial units Anchor Information: Anchor type: Torque controlled expansion anchor Material: Carbon Steel Diameter (inch): 0.375 Nominal Embedment depth (inch): 2.875 Effective Embedment depth, hef (inch): 2.500 Code report: ICC-ES ESR-3037 Anchor category: 1 Anchor ductility: Yes hmin (inch): 4.50 cac (inch): 6.00 Cmin (inch): 6.00 Smin (inch): 3.00 Base Material Concrete: Normal-weight Concrete thickness, h (inch): 5.00 State: Cracked Compressive strength, f’c (psi): 2500 Ψc,V: 1.0 Reinforcement condition: Supplementary reinforcement not present Supplemental edge reinforcement: Not applicable Reinforcement provided at corners: No Ignore concrete breakout in tension: No Ignore concrete breakout in shear: No Ignore 6do requirement: Not applicable Build-up grout pad: No Recommended Anchor Anchor Name: Strong-Bolt® 2 - 3/8"Ø STB2, hnom:2.875" (73mm) Code Report: ICC-ES ESR-3037 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 25/29 jose@ramirezstructural.com (562) 519-6045 Company:RAMIREZ STRUCTURAL Date:2/17/2023 Engineer:JOSE RAMIREZ Page:2/5 Project:24-221 Address:3535 W Garry Ave Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2404.1 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: No Anchors subjected to sustained tension: Not applicable Apply entire shear load at front row: Yes Anchors only resisting wind and/or seismic loads: No Strength level loads: Nua [lb]: 670 Vuax [lb]: 0 Vuay [lb]: 900 <Figure 1> Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 26/29 jose@ramirezstructural.com (562) 519-6045 Company:RAMIREZ STRUCTURAL Date:2/17/2023 Engineer:JOSE RAMIREZ Page:3/5 Project:24-221 Address:3535 W Garry Ave Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2404.1 <Figure 2> 3. Resulting Anchor Forces Anchor Tension load, Nua (lb) Shear load x, Vuax (lb) Shear load y, Vuay (lb) Shear load combined, √(Vuax)²+(Vuay)² (lb) 1 670.0 0.0 900.0 900.0 Sum 670.0 0.0 900.0 900.0 Maximum concrete compression strain (‰): 0.00 Maximum concrete compression stress (psi): 0 Resultant tension force (lb): 670 Resultant compression force (lb): 0 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 Eccentricity of resultant shear forces in x-axis, e'Vx (inch): 0.00 Eccentricity of resultant shear forces in y-axis, e'Vy (inch): 0.00 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 27/29 jose@ramirezstructural.com (562) 519-6045 Company:RAMIREZ STRUCTURAL Date:2/17/2023 Engineer:JOSE RAMIREZ Page:4/5 Project:24-221 Address:3535 W Garry Ave Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2404.1 4. Steel Strength of Anchor in Tension (Sec. 17.6.1) Nsa (lb)Nsa (lb) 5600 0.75 4200 5. Concrete Breakout Strength of Anchor in Tension (Sec. 17.6.2) Nb = kc a f’chef1.5 (Eq. 17.6.2.2.1) kc a f’c (psi)hef (in)Nb (lb) 17.0 1.00 2500 2.500 3360 Ncb =(ANc / ANco)ed,N c,N cp,NNb (Sec. 17.5.1.2 & Eq. 17.6.2.1a) ANc (in2)ANco (in2)ca,min (in)ed,N c,N cp,N Nb (lb)Ncb (lb) 56.25 56.25 -1.000 1.00 1.000 3360 0.65 2184 6. Pullout Strength of Anchor in Tension (Sec. 17.6.3) Npn =c,P aNp(f’c /2,500)n (Sec. 17.5.1.2, Eq. 17.6.3.1 & Code Report) c,P a Np (lb)f’c (psi)n Npn (lb) 1.0 1.00 2775 2500 0.50 0.65 1804 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 28/29 jose@ramirezstructural.com (562) 519-6045 Company:RAMIREZ STRUCTURAL Date:2/17/2023 Engineer:JOSE RAMIREZ Page:5/5 Project:24-221 Address:3535 W Garry Ave Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2404.1 8. Steel Strength of Anchor in Shear (Sec. 17.7.1) Vsa (lb)grout grout Vsa (lb) 1800 1.0 0.65 1170 10. Concrete Pryout Strength of Anchor in Shear (Sec. 17.7.3) Vcp =kcpNcb =kcp(ANc / ANco)ed,N c,N cp,NNb (Sec. 17.5.1.2 & Eq. 17.7.3.1a) kcp ANc (in2)ANco (in2)ed,N c,N cp,N Nb (lb)Vcp (lb) 2.0 56.25 56.25 1.000 1.000 1.000 3360 0.70 4704 11. Results Interaction of Tensile and Shear Forces (Sec. R17.8) Tension Factored Load, Nua (lb)Design Strength, øNn (lb)Ratio Status Steel 670 4200 0.16 Pass Concrete breakout 670 2184 0.31 Pass Pullout 670 1804 0.37 Pass (Governs) Shear Factored Load, Vua (lb)Design Strength, øVn (lb)Ratio Status Steel 900 1170 0.77 Pass (Governs) Pryout 900 4704 0.19 Pass Interaction check (Nua/ɸNua)5/3 (Vua/ɸVua)5/3 Combined Ratio Permissible Status Sec. R17.8 0.19 0.65 83.8%1.0 Pass 3/8"Ø STB2, hnom:2.875" (73mm) meets the selected design criteria. 12. Warnings - Designer must exercise own judgement to determine if this design is suitable. - Refer to manufacturer’s product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com ENGINEERED BY: JOSE RAMIREZ, PE JOB: 3535 W GARRY AVE JOB NO.: 24-221 DATE:05/15/24 SHEET NO.: 29/29 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments • Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. • Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. • If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. • In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. • Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 3535 W Garry Ave ✔ 2-Tier Cannabis Cultivaiton Racks ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Brad Kenson 949 228-5687 07 01 24 Santa Ana O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs