Laserfiche WebLink
SHEET NAME: <br />DATE: <br />SCALE: <br />DRAWN BY: <br />PROJECT #: <br />SHEET NUMBER:REV: <br />AI <br />R <br />B <br />O <br />R <br />N <br />E <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />S <br />31 <br />0 <br />0 <br /> <br />W <br />. <br /> <br />S <br />E <br />G <br />E <br />R <br />S <br />T <br />R <br />O <br />M <br /> <br />A <br />V <br />E <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />02.27.2025 <br />JM <br />03 <br />. <br />0 <br />5 <br />. <br />2 <br />4 <br />_ <br />A <br />I <br />R <br />B <br />O <br />R <br />N <br />E <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />S <br />_ <br />S <br />Y <br />8 <br />8 <br />4 <br />0 <br />4 <br />1 <br />_ <br />R <br />1 <br />. <br />D <br />W <br />G <br />SY884041 <br />1 <br />STRUCTURAL STAMP <br />CU <br />S <br />T <br />O <br />M <br />E <br />R <br />: <br />REV.14 <br />SANTA FE SPRINGS, CA <br />9939 NORWALK BLVD, <br />SANTA FE SPRINGS, CA 90670 <br />PHONE: 562.944.8067 <br />This drawing is the property of Raymond West and is <br />only to be used only by the party described in the <br />"Customer" section and then only in connection with <br />its purchase or use of Raymond West products, <br />services or systems. Copying in part or as a whole is <br />prohibited. This is subject to a Confidentiality <br />Agreement between Raymond West and the party <br />described under "Customer". <br />All dimensions are to be field verified by the <br />customer. Raymond West assumes no responsibility for <br />incorrect dimensions, location of lights or other <br />equipment outside of Raymond West's scope of work. <br />https://raymondwest.com <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />RE <br />V <br />. <br /> <br />B <br />Y <br />: <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />: <br />RE <br />V <br />. <br /> <br />N <br />O <br />. <br />RE <br />V <br />. <br /> <br />D <br />A <br />T <br />E <br />: <br />0 <br />I <br />N <br />I <br />T <br />I <br />A <br />L <br /> <br />R <br />E <br />L <br />E <br />A <br />S <br />E <br />   <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />TITLE SHEET <br />SS1 <br />X" = 1'-0" <br />NORTH <br />SITE <br />LOCATION <br />A.STORAGE CAPACITY SIGNS <br />1. PER RMI 1.4.2, ONE OR MORE PLAQUES WILL BE PLACED <br />CONSPICUOUSLY IN CLEAR AND LEGIBLE MANNER TO <br />IDENTIFY EACH DIFFERENT RACK CONFIGURATION. <br />2. EACH PLAQUE TO BE A MINIMUM OF 50 SQUARE INCHES. IT <br />IS THE OWNERS RESPONSIBILITY TO ENSURE THE RACK <br />SYSTEM IS NOT ALTERED SO THAT THE PLAQUE <br />INFORMATION IS INVALIDATED. <br />3. EACH PLAQUE TO DISPLAY: <br />i. THE MAXIMUM PERMISSIBLE LOAD AND/OR THE <br />MAXIMUM DISTRIBUTED LOAD PER LEVEL <br />ii. THE AVERAGE LOAD IF APPLICABLE AND <br />iii. MAXIMUM TOTAL LOAD PER BAY. <br />B. WELDING <br />1. ALL WELDING, EXCEPT WHEN PERFORMED AT THE SHOP OF <br />AN APPROVED FABRICATOR, SHALL BE DONE BY CERTIFIED <br />WELDERS. WELDING CERTIFICATES PROVIDED UPON <br />REQUEST. <br />2. SPECIAL INSPECTIONS REQUIRED FOR ANY STRUCTURAL <br />FIELD WELDING. <br />C. ANCHORING/HARDWARE <br />1. PER IBC, SPECIAL INSPECTION IS REQUIRED FOR THE <br />INSTALLATION OF ANCHOR BOLTS. <br />2. ANCHOR SIZE, PLACEMENT, AND EMBEDMENT SPECIFIED BY <br />A LICENSED PROFESSIONAL STRUCTURAL ENGINEER. <br />3. PER IBC, PERIODIC SPECIAL INSPECTION IS REQUIRED FOR <br />THE INSTALLATION OF CONCRETE ANCHOR BOLTS OF <br />STORAGE RACKS 8 FEET OR GREATER FOR STRUCTURES <br />ASSIGNED TO SEISMIC DESIGN CATEGORIES D, E, OR F. <br />4. HARDWARE OTHER THAN ANCHORS TO BE SPECIFIED BY A <br />LICENSED PROFESSIONAL STRUCTURAL ENGINEER. <br />D. MAINTENANCE <br />1. THE OWNER SHALL MAINTAIN THE STRUCTURAL INTEGRITY <br />OF THE RACK SYSTEM BY ASSURING PROPER OPERATIONAL, <br />HOUSEKEEPING, AND MAINTENANCE PROCEDURES, <br />INCLUDING BUT NOT LIMITED TO THE FOLLOWING: <br />i. PROHIBIT ANY OVER LOADING OF ANY PALLET <br />POSITIONS AND OF THE OVERALL RACK SYSTEM <br />ii. REGULAR INSPECTIONS FOR DAMAGE. IF DAMAGED <br />COLUMNS OR BEAMS ARE FOUND, IMMEDIATELY <br />UNLOAD THE AFFECTED AREA AND REPLACE OR <br />REPAIR ANY DAMAGED COLUMNS, BEAMS, OR OTHER <br />STRUCTURAL COMPONENTS. <br />iii. REQUIRE ALL PALLETS BE MAINTAINED IN GOOD, SAFE <br />OPERATING CONDITION. <br />iv. ENSURE THAT PALLETS ARE PROPERLY PLACED ONTO <br />PALLET LOAD SUPPORT MEMBERS IN STACKED AND <br />STABLE POSITIONS. <br />v. ALL GOODS STORED ON EACH PALLET ARE STACKED <br />AND IN STABLE POSITIONS. <br />vi. ENSURE THAT THE RACKS ARE NOT MODIFIED OR <br />REARRANGED IN A MANNER NOT WITHIN THE <br />ORIGINAL DESIGN CONFIGURATIONS. <br />vj. IF CONFIGURATION CHANGES ARE REQUIRED, NEW <br />STRUCTURAL ANALYSIS MUST BE PERFORMED TO <br />ENSURE PROPER LOADING. <br />vk. THE MAXIMUM TOP TO BOTTOM OUT-OF PLUMB <br />RATIO AND OUT-OF STRAIGHT RATIO PER RACK <br />COLUMN IS 1/240 (FOR EXAMPLE 1/2" PER 10 FEET OF <br />HEIGHT). COLUMNS WHOSE OUT-OF-PLUMB RATIO OR <br />OUT-OF-STRAIGHT RATIO EXCEEDS THIS LIMIT SHOULD <br />BE UNLOADED AND RE-PLUMBED. ANY DAMAGES <br />PARTS MUST BE REPAIRED OR REPLACED. <br />E. CONFIGURATION CHANGES <br />1. THIS SET OF DRAWINGS SHOWS ALL THE PERMISSABLE <br />CONFIGURATIONS OF THESE COMPONENTS PER THIS <br />PERMITTED DRAWING SET. OTHER CONFIGURATIONS MAY <br />PERMITTED UPON REVIEW OF THE ENGINEER OF RECORD <br />FOR THIS PROJECT AND REVISIONS TO THE DRAWING <br />ACCORDINGLY. <br />2. ANY CHANGES TO THE CONFIGURATION OF THE RACK <br />SYSTEM COMPONENTS INCLUDING RELOCATION OR <br />REMOVAL OF THE SHELF BEAM OR ANY OTHER <br />COMPONENTS WITHOUT PERMISSION IS NOT PERMITTED <br />VICINITY MAP PROJECT TEAMSHEET INDEX <br />  <br />DEFERRED SUBMITTALS <br />  <br />  <br />  <br />  <br />  <br /> <br />GENERAL NOTES: <br />PROJECT/SITE INFORMATION <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />APPLICABLE CODES <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />PRODUCTS TO BE STORED ARE THE FOLLOWING: <br />STEEL PARACHUTE COMPONENTS, CARDBOARD AND WOOD PACKING MATERIALS, 99% NYLON <br />FABRIC PARACHUTES, NYLON TAPES, NYLON WEBBINGS, AND SHORT ROLLS OF PALLETIZED <br />NYLON FABRIC MATERIAL. THIS IS A CLASS I - IV COMMODITY NON-ENCAPSULATED, EXPOSED. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />(6)6,2 251$3 /'((15*(7 ,16,(*((55 <br />$&/),)2 2(571$,7 $6 9 ,,/& <br />((55 <br />$&/),)2 2(555555555555555555555555555555555555555555555555555555555777777777777777777777777777777777777777777777777111111111111111111111111111111111111111111111111111111111$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$7 ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,7$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$66666666666666666666666666666666666666666666666 9 ,,/////////////&&&&&&&&&&&&&&&&&&&&&&&&&&&&&& <br />1R1R <br />(([S[S <br />THE P.E. CERTIFICATION PROVIDED HEREIN PERTAINS <br />505)&"%&26"$: 0'5)&4503"(& 3"$, <br />4536$563"-$0.10/&/540/-:"-- <br />05)&3"3&"4"3&0654*%&5)&4$01&0' <br />803,0'5)*4$&35*'*$"5*0/. <br />3/12/25Bldg #101121507 <br />APPROVALS: <br />PLNG - F. Arias <br />BLDG - CSG <br />PUBLIC WORKS - Y. Soto