HomeMy WebLinkAbout301 E Colombine Ave - Plan&
<
@
#
Ø
AB
ABV
A/C
A.C.
ACT
ACOUS
ADJ
ADA
AFF
ALT
ALUM
ANOD
A.P.
APPROX
ARCH
ASPH
AV
BATT
BD
BITUM
BLDG
BLK
BLKG
BM
BOT
BR
BSMT
B.U.R.
CAB
CARP
CATV
C.B.
CCTV
CEM
CER
CFM
CL
CLG
CLO
CLR
CMU
CNTR
COL
CONC
CONN
CONST
CONT
CONTR
CORR
C.T.
CTSK
C.W.
(D)
D
DATA
DBL
DEMO
DET
DIA
DIM
DISP
DN
D.O.
DR
DS
D.S.P.
DW
DWG
DWR
(E)
EA
EJ
ELEC
ELEV
EMER
ENCL
EPO
E.O.S.
EQ
EQUIP
EXIST
EXP
EXPO
EXT
F.A.
F.D.
FDN
FEC
FF
F.G.
FHC
FIN
FLR
FLUOR
F.O.C.
F.O.F.
F.O.M.
F.O.S.
FPRF
FR
FS
FT
FTG
FURN
FURR
GA
GALV
GC
GFI
GL
GND
GR
GWB
GYP
H
H.B.
H.C.
HDWR
HDWD
HM
HORIZ
HR
HT
HVAC
H.W.
AND
ANGLE
AT
NUMBER
DIAMETER OR ROUND
ANCHOR BOLT
ABOVE
AIR CONDITIONING
ASPHALT CONCRETE
ACOUSTICAL CEILING TILE
ACOUSTICAL
ADJACENT
AMERICANS WITH DISABILITIES ACT
ABOVE FINISH FLOOR
ALTER OR ALTERNATE
ALUMINUM
ANODIZED
ACCESS PANEL
APPROXIMATE
ARCHITECTURAL
ASPHALT
AUDIO VISUAL
BATT INSULATION
BOARD
BITUMINOUS
BUILDING
BLOCK
BLOCKING
BEAM
BOTTOM
BEDROOM
BASEMENT
BUILT UP ROOFING
CABINET
CARPET
CABLE TELEVISION
CATCH BASIN
CLOSED CIRCUIT TELEVISION
CEMENT
CERAMIC
CUBIC FEET PER MINUTE
CENTER LINE
CEILING
CLOSET
CLEAR
CONCRETE MASONRY UNIT
CENTER
COLUMN
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CORRIDOR
CERAMIC TILE
COUNTERSUNK
COLD WATER
DEMOLISH
DEEP, DEPTH
DATA COMMUNICATIONS
DOUBLE
DEMOLISH / DEMOLITION
DETAIL
DIAMETER
DIMENSION
DISPENSER
DOWN
DOOR OPENING
DOOR
DOWNSPOUT
DRY STANDPIPE
DISHWASHER
DRAWING
DRAWER
EXISTING
EACH
EXPANSION JOINT
ELECTRICAL
ELEVATION
EMERGENCY
ENCLOSURE
EMERGENCY POWER OFF
EDGE OF SLAB
EQUAL
EQUIPMENT
EXISTING
EXPANSION
EXPOSED
EXTERIOR
FIRE ALARM
FIRE DRAIN
FOUNDATION
FIRE EXTINGUISHER CABINET
FINISHED FACE
FINISH GRADE
FIRE HOSE CABINET
FINISH
FLOOR
FLUORESCENT
FACE OF CONCRETE
FACE OF FINISH
FACE OF MASONRY
FACE OF STUD
FIREPROOF
FRAME
FULL SIZE
FOOT, FEET
FOOTING
FURNITURE
FURRING, FURRED
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GROUND FAULT INTERRUPT
GLASS, GLAZING
GROUND
GRADE
GYPSUM WALL BOARD
GYPSUM
HIGH
HOSE BIB
HOLLOW CORE
HARDWARE
HARDWOOD
HOLLOW METAL
HORIZONTAL
HOUR
HEIGHT
HEATING, VENTILATION, AND
AIR CONDITIONING
HOT WATER
I.D.
INCL
INFO
INSUL
INT
JAN
JST
JT
KIT
LAM
LAV
L.F.
L.H.
L.R.
LT
LVR
MATL
MAX
MDF
MECH
MFR
MIN
MIR
MISC
M.O.
M.R.
MTD
MTL
MUL
(N)
NA
NIC
NO
NOM
N.S.
N.T.S.
O/
OC
O.D.
O.F.D.
O.H.
OVHD
OPNG
OPP
P.D.
PG
P.L.
P-LAM
PLAS
PLMG
PLYWD
PR
PSF
PT
PTD
PTN
(R)
R
RAD
RCP
R.D.
REF
REFR
REINF
REP
REQD
RESIL
REV
RFG
R.H.
RM
ROM
R.O.
S.X.D.
S.C.
SCHED
SDT
SECT
SEP
SF
SGL
SHR
SHT
SIM
SLDG
SPEC
SQ
S.S.
STD
STL
STRUCT
SUSP
SW
SYM
T
T&G
TBD
TELE
TEMP
TER
THK
THR
T.O.C.
T.O.D.
T.O.P.
T.O.S.
T.S.
T.O.W.
TYP
UON
VCT
VERT
VEST
VIF
VOL
W/
W.C.
WD
W.H.
W/O
WP
WPM
WSCT
W.S.P.
WT
INSIDE DIAMETER
INCLUDING
INFORMATION
INSULATION
INTERIOR
JANITOR
JOIST
JOINT
KITCHEN
LAMINATE
LAVATORY
LINEAL FOOT
LEFT HAND
LIVING ROOM
LIGHT
LOUVER
MATERIAL
MAXIMUM
MEDIUM DENSITY FIBER BOARD
MECHANICAL
MANUFACTURER
MINIMUM
MIRROR
MISCELLANEOUS
MASONRY OPENING
MOISTURE RESISTANT
MOUNTED
METAL
MULLION
NEW
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOMINAL
NO SCALE
NOT TO SCALE
OVER
ON CENTER
OUTSIDE DIAMETER
OVERFLOW DRAIN
OVERHAND
OVERHEAD
OPENING
OPPOSITE
PLANTER DRAIN
PAINT GRADE
PROPERTY LINE
PLASTIC LAMINATE
PLASTER
PLUMBING
PLYWOOD
PAIR
POUNDS PER SQUARE FOOT
PAINT
PAINTED
PARTITION
RELOCATED
RISER
RADIUS
REFLECTED CEILING PLAN
ROOF DRAIN
REFERNCE
REFRIDGERATOR
REINFORCED
REPRESENTATIVE
REQUIRED
RESILIENT
REVISED
ROOFING
RIGHT HAND
ROOM
ROUGH ORDER OF MAGNITUDE
ROUGH OPENING
SEE (X=DISCIPLINE) DRAWINGS
SOLID CORE
SCHEDULE
STATIC DISSIPATIVE TILE
SECTION
SEPARATION
SQUARE FOOT / FEET
SINGLE
SHOWER
SHEET
SIMILAR
SLIDING
SPECIFICATION
SQUARE
STAINLESS STEEL
STANDARD
STEEL
STRUCTURAL
SUSPENDED
SWITCH
SYMMETRICAL
TREAD
TONGUE AND GROVE
TO BE DETERMINED
TELECOMMUNICATIONS
TEMPERATURE/TEMPERED
TERRAZZO
THICK
THRESHOLD
TOP OF CURB
TOP OF DRAIN
TOP OF PAVEMENT
TOP OF SLAB
TOP OF STEEL
TOP OF WALL
TYPICAL
UNLESS OTHERWISE NOTED
VINYL COMPOSITION TILE
VERTICAL
VESTIBULE
VERIFY IN FIELD
VOLUME
WITH
WATER CLOSET
WOOD
WATER HEATER
WITHOUT
WATERPROOF
WATERPROOF MEMBRANE
WAINSCOT
WET STANDPIPE
WEIGHT
BUILDING GRID LINES
WINDOW SYMBOL
ROOM NO.
REFERENCE LETTER
DOOR SYMBOL
REVISION NO.
REVISION CLOUD
MATCH LINE
DETAIL NO.
1/A3.2
ROOM NAME
ROOM NO.
ROOM LABEL
SECTION
SECTION NO.
SHEET NO.
AREA REFERENCE
DETAIL NO.
SHEET NO.
DETAIL
EXTERIOR ELEVATION
ELEVATION NO.
SHEET NO.
DIMENSION STRING
INTERIOR ELEVATION
ELEVATION NO.
(TYPICAL)
SHEET NO.
CEILING
WORK POINT OR
CONTROL POINT
NORTH ARROW
AR
C
H
I
T
E
C
T
U
R
A
L
N
O
R
T
H
TRUE NORTH
1"
A101
1 Ref
1
Re
f
1 Ref
1
Re
f
1t
0
0
101
ROOM NO.
REFERENCE NO.
A101
1
SIM
1
A101
SIM
A101
1
Ref
1Re
f
1 Re
f
1
Ref
A.F.F.
1t
1'-0"
SHEET NO.
1
ROOM NAME
101
N
MISC. SYMBOLS
(D)
(R)
(E)
(N)
INDICATES ITEM TO BE DEMOLISHED
INDICATES ITEM TO BE REMOVED AND
RELOCATED
INDICATES ITEM EXISTING TO REMAIN
INDICATES NEW ITEM
TYPE
HEIGHT
DISCIPLINE ABBREVIATIONS
G:
D:
C:
S:
A:
M:
E:
P:
LV:
AV:
SE:
VT:
FSE:
L:
GENERAL
DEMOLITION
CIVIL
STRUCTURAL
ARCHITECTURAL
MECHANICAL
ELECTRICAL
PLUMBING
LOW VOLTAGE
AUDIO/VISUAL
SECURITY
VERTICAL TRANSPORTATION
FOOD SERVICE
LANDSCAPE
A0
3B
WALL SYMBOL
ASSEMBLY TYPE
FRAMING SIZE
ACOUSTICAL
HEIGHT & FIRE-RATING
PROJECT
NORTH
TRUE
NORTH
N
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND
UNPUBLISHED WORK OF THE ARCHITECT AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED
WITHOUT WRITTEN CONSENT OF ARCHITECT. COPYRIGHTED.
PROJECT NO.CHECKED BY
SHEET NO.
SCALE @ ARCH E1
SHEET NAME
CLIENT NAME
ARCHITECT'S STAMP
PROJECT TEAM
KEY PLAN
MEP ENGINEER
STRUCTURAL ENGINEER
OTHER CONSULTANT
CIVIL ENGINEER
LANDSCAPE ARCHITECT
COLUMBINE AVE.
MA
P
L
E
A
V
E
.
(E) OFFICE BLG
GARAGE
4/
1
0
/
2
0
2
5
1
:
5
9
:
0
9
P
M
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
S
o
C
a
l
G
a
s
-
S
a
n
t
a
A
n
a
B
a
s
e
/
S
o
C
a
l
G
a
s
-
S
a
n
t
a
A
n
a
B
a
s
e
.
r
v
t
As indicated24021
G0.01
SOCAL GAS -SANTA ANA BASE
301 E COLUMBINE AVE
SANTA ANA, CA 92707
Approver
PROJECT INFORMATION
SOCAL GAS
SITE WALL PERMIT
SHEET NUM SHEET NAME IS
S
U
E
F
O
R
P
E
R
M
I
T
01 GENERAL
G0.01 PROJECT INFORMATION ⬛
04 ARCHITECTURAL
A1.00 SITE PLAN ⬛
05 STRUCTURAL
S-0 SITE WALLS STANDARD DETAILS ⬛
SHEET INDEXABBREVIATIONS
1. -
DEFERRED SUBMITTALS
PROJECT INFORMATIONPROJECT TEAM
VICINITY MAP
SYMBOLS
STRUCTURAL ENGINEER
HUSAM GHANIM
GHANIM STRUCTURAL ENGINEERING
898 N. FAIR OAKS AVE., SUITE F
PASADENA, CA 91103
T (323) 494-3208
E husam@ghanimSE.com
ARCHITECT
KEITH MULLER, AIA
FORMM
101 N PACIFIC COAST HWY, SUITE 301
EL SEGUNDO, CA 90245
T (619) 204-2036
E keith@formmstudio.com
301 E COLUMBINE AVE
SANTA ANA, CA 92707
N/A
N/A
N/A
N/A
N/A
NEW 8' CMU SITE WALLS TO MATCH EXISTING AT
PROPERTY LINES, TO INFILL (E) GAPS AND PROVIDE
ADEQUATE SITE SECURITY TO THE FACILITY, 595'-2"
TOTAL LENGTH
LOCATION:
BUILDING CONSTRUCTION TYPE
FIRE SPRINKLER SYSTEM
# OF FLOORS IN BUILDING:
OCCUPANCY:
TOTAL AREA OF WORK :
SCOPE OF PROJECT:
CODES & REGULATIONS:
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA FIRE CODE
2022 CALIFORNIA ENERGY CODE
2022 NFPA 72 (FIRE ALARMS)
2022 NFPA 13 (SPRINKLERS)
03/15/11 ADA REGULATION FOR TITLE III,
CODE OF FEDERAL REGULATIONS (CBC 2019 CH. 11)
03/15/11 ADA REGULATION FOR TITLE II,
FEDERAL REGISTER (CBC 2019 CH. 11)
SCOPE OF WORK DIAGRAM
EXTENT OF (N) SITE WALLS ALONG PERIMETER
ALONG PROPERTY LINES TO MATCH (E) SITE WALLS
ISSUE RECORD
∆ DATE REASON FOR ISSUE BY
HB
G
E
RSR
MASONRY WALL
CONCRETE WALL
PROPERTY LINE
TOPOGRAPHY
SETBACK
GAS BIB
HOSE BIB
GAS METER | GAS LINE
ELECTRICAL SERVICE | ELECTRICAL LINE
EASEMENT
WATER METER | WATER LINEW
E
G G
E
W
00
COMM SERVICE | COMM LINEC C
1. THE SITE SHALL BE FULLY FENCED PRIOR TO THE START OF CONSTRUCTION
2. ALL ON-SITE LITTER AND DEBRIS SHALL BE COLLECTED DAILY
3. CONSTRUCTION WORK SHALL OCCUR ONLY BETWEEN THE HOURS OF 7:00 A.M. AND 6:00 P.M.
ON MONDAY THROUGH FRIDAY, BETWEEN 9:00 A.M. AND 5:00 P.M. ON SATURDAY, WITH NO
WORK OCCURRING ON SUNDAY AND HOLIDAYS
4. MATERIAL STORAGE ON PUBLIC STREETS SHALL NOT EXCEED 48-HOURS PER LOAD
5. STREETS AND SIDEWALKS ADJACENT TO JOB SITES SHALL BE CLEAN AND FREE OF DEBRIS.
6. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, GRADES, ELEVATIONS AND
DIMENSIONS BEFORE STARTING WORK. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF
ANY DISCREPANCIES OR INCONSISTENCIES.
7. INSTALL EXPANSION JOINTS AT ALL LOCATIONS WHERE PAVEMENT MEETS BUILDING, WALLS,
CURBS, AND OTHER PERMANENT STRUCTURES.
8. REFER TO CIVIL DRAWINGS FOR GRADING, DRAINAGE, UTILITIES AND PUBLIC RIGHT-OF-WAY
IMPROVEMENTS.
9. REFER TO LANDSCAPE DRAWINGS FOR HARDSCAPE, PLANTERS, AND SITE FURNITURE
10. SEE CONSTRUCTION PLANS FOR WALL SCHEDULES
11. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.) UNLESS OTHERWISE NOTED.
12. DO NOT SCALE FROM DRAWINGS.
13. ANY INCONSITENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT
PRIOR TO PROCEEDING WITH CONSTRUCTION.
14. AN APPROVED SEISMIC SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE
DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR
OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING.
15. CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN TEMPORARY BARRIERS AND GUARDS,
AND ALL TEMPORARY SHORING AND BRACING AS REQUIRED BY ALL CITY AND STATE
REGULATIONS.
16. CONTRACTOR SHALL PROVIDE ADEQUATE WEATHER PROTECTION FOR THE BUILDING AND
ITS CONTENTS DURING THE COURSE OF WORK.
17. CONTRACTOR TO PROVIDE TEMPORARY POWER POLE AND METER FOR THE DURATION OF
THE WORK.
18. CONTRACTOR TO MAINTAIN TEMPORARY LIGHT AS REQUIRED FOR THE DURATION OF THE
WORK.
19. CONTRACTOR SHALL PROVIDE TEMPORARY SANITARY FACILITIES AS TO LEAST IMPACT
NEIGHBORS AND AS DIRECTED BY CITY REGULATIONS.
20. PROTECT IN-PLACE ALL SURVEY MONUMENTS AND PROPERTY CORNER MARKERS.
21. GC TO VERIFY THAT (E) SEWER LATERAL IS IN GOOD WORKING ORDER, PROVIDE SEWER
CAMERA INSPECTION IF REQUIRED TO BE REPLACED. GC TO PROVIDE NEW LATERAL WITH
EITHER BACKFLOW PREVENTION DEVICE OR CLEANOUT ON-SITE.
CL
CL
(E) MAIN OFFICE BUILDING
3
A1.00
2
A1.00
NEW CMU WALL
317' - 6"
NEW CMU WALL
26
1
'
-
5
"
NE
W
C
M
U
W
A
L
L
16
'
-
8
"
(E
)
G
A
R
A
G
E
B
U
I
L
D
I
N
G
COLOMBINE AVE
MA
P
L
E
A
V
E
30' - 0"
30
'
-
0
"
(E) GRADE TO REMAIN
(E) CMU SITE WALL TO REMAIN
P/L, TYP.
(E) GRADE
(N) CMU SITE WALL, FINISH AND ELEV.
TO MATCH (E). REF. 7/S-0 FOR
STRUCTURAL DETAILS
P/L, TYP.
N
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND
UNPUBLISHED WORK OF THE ARCHITECT AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED
WITHOUT WRITTEN CONSENT OF ARCHITECT. COPYRIGHTED.
PROJECT NO. CHECKED BY
SHEET NO.
SCALE @ ARCH E1
SHEET NAME
CLIENT NAME
ARCHITECT'S STAMP
PROJECT TEAM
KEY PLAN
MEP ENGINEER
STRUCTURAL ENGINEER
OTHER CONSULTANT
CIVIL ENGINEER
LANDSCAPE ARCHITECT
COLUMBINE AVE.
MA
P
L
E
A
V
E
.
(E) OFFICE BLG
GARAGE
4/
1
0
/
2
0
2
5
1
:
5
9
:
1
0
P
M
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
S
o
C
a
l
G
a
s
-
S
a
n
t
a
A
n
a
B
a
s
e
/
S
o
C
a
l
G
a
s
-
S
a
n
t
a
A
n
a
B
a
s
e
.
r
v
t
As indicated24021
A1.00
SOCAL GAS -SANTA ANA BASE
301 E COLUMBINE AVE
SANTA ANA, CA 92707
Approver
SITE PLAN
SOCAL GAS
SITE WALL PERMIT
3/64" = 1'-0"1OVERALL SITE PLAN
KEYNOTESLEGENDSHEET NOTES
1/2" = 1'-0"2EXISTING CMU PROPERTY WALL
1/2" = 1'-0"3PROPOSED CMU PROPERTY WALL
ISSUE RECORD
∆ DATE REASON FOR ISSUE BY
WALL REINF.
VERT. CORNER
BAR TO MATCH
SIZE OF VERT.
LOCATION OF VERT. & HORIZ.
SEE WALL DETAILS FOR SIZE &
REINF. IN WALL
#4 BAR TO MATCH
SPACING OF HORIZ.
WALL REINF.
2'
-
0
"
2'-0"
SEALANT W/ BACKING ROD,
FOR REINF., TYP.
SEE WALL SECT.
TYP. EA. SIDE OF JOINT
NOTES:
SHOWN EXCEPT BARS @ TOP
OF WALL; TOP BARS SHALL
BE CONTINUOUS THRU JOINT
( LOCATION OF CONTROL JOINTS )
NEAR WALL INTERSECTIONS
AT REGULAR INTERVALS NOT TO EXCEED 40'-0"
AT PILASTERS
PLAN DETAIL
2.
3.
1.
B
TOP BARS
SEE WALL
SECTIONS
B
TOP OF WALL ELEVATION
CUT ALL HORIZ. BARS AS
A
2"
CL.
2"
CL.
3
8" EXPANSION
JT. AS OCCURS
2"
CL.
2"
CL.
SE
E
WA
L
L
SE
C
T
I
O
N
S
VERT. BARS EA. SIDE OF JOINT
CONTINUOUS
SCOPE OF WORK:
LIMITED TO STRUCTURAL SITE WALL DESIGN AND DETAILING
FOR CONSTRUCTION OF:
1. ONE (1) FREESTANDING CMU WALL
REFERENCES
THE WORK IS BASED ON THE INFORMATION SET FORTH IN
THE FOLLOWING REFERENCES.
GEOTECHNICAL INVESTIGATION: NOVA SERVICES, INC.,
PROJECT NO. 3024029,
JANUARY 30, 2025.
S-DT0003
12
Ø
(
1
2
"
m
i
n
.
)
U.
N
.
O
.
4"Ø" - 21
2" min
LAP IN MASONRY PER
CONSTRUCTION NOTE 1
(24"min.)
36Ø LAP IN CONCRETE
(18"min.)
LAP AND OFFSET
'D'=8d FOR #9 BAR AND LARGER
'D'=6d FOR #8 BAR AND SMALLER
"D"
BAR BENDS
"D"
4"
STIRRUP OR TIE
"Ø
"
"D""D"
TYPICAL MASONRY WALL STEPPED FOOTING 2
TYPICAL REINFORCING 1
TYPICAL EXPANSION JOINT 3
CMU WALL INTERSECTION 4
DRAINAGE BLOCK-OUT 5
REBAR LOCATION DETAIL 6
STRUCTURAL NOTES -
AS SHOWN.
1/2 BLK. DRAIN
SIDE OF THE
BAR ON EA.
& #4 DROP-IN
PROVDE #4 DWL.
SWALE GRADE.
BE LEFT OUT AT
A 1/2 BLK. MAY
SWALE OCCURS,
WHERE DRAINAGE
RETURN WALLS
FOR SIDEYARD
4"4"
#4 DWL. @ EA.
SIDE OF BLOCK-
OUT w/ #4
DROP-IN BAR
8"x8" BLOCK-
OUT
CONT. FTG.
NOTE:
GENERAL
1.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS AND
SPECIFICATIONS.
2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL
TRADES AND SHALL CHECK ALL DIMENSIONS BEFORE COMMENCING WORK AND
REPORT ANY DISCREPANCIES.
3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING DURING
CONSTRUCTION AND SHALL PROVIDE ADEQUATE SHORING, BRACING AND GUYS
DURING CONSTRUCTION. SAFETY AND BRACING REQUIREMENTS SHALL BE IN
ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES.
4.THE CONTRACTOR SHALL BECOME FAMILIAR WITH AND COMPLY WITH ALL OF THE
GENERAL PROVISIONS OF IBC CHAPTER 33 FOR ALL BUILDING AND SITE WORK,
DEMOLITION AND CONSTRUCTION.
5.IN ALL CASES WHERE A CONFLICT MAY OCCUR, SUCH AS BETWEEN ITEMS COVERED IN
STRUCTURAL SPECIFICATIONS AND NOTES ON THE DRAWINGS OR BETWEEN GENERAL
NOTES AND SPECIFIC DETAILS, THE ENGINEER OF RECORD SHALL BE NOTIFIED AND HE
WILL INTERPRET THE INTENT OF THE CONTRACT DOCUMENTS PRIOR TO INSTALLATION
OF THAT PORTION OF WORK.
6.SIMILAR WORK: WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY
PART OF THE WORK, SUCH DETAILS SHALL BE THE SAME AS FOR SIMILAR WORK
SHOWN ON THE DRAWINGS.
7.PIPES, DUCTS, SLEEVES, CHASES, ETC.: SHALL NOT BE PLACED IN SLABS, BEAMS, OR
WALLS UNLESS SPECIFICALLY SHOWN OR NOTED NOR SHALL ANY STRUCTURAL
MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS SPECIFICALLY SHOWN. OBTAIN
PRIOR WRITTEN APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC.
8.LOCATE AND PROTECT UNDERGROUND OR CONCEALED CONDUIT, PLUMBING OR
OTHER UTILITIES WHERE NEW WORK IS BEING PERFORMED. IDENTIFY AND LOCATE
ANY SUBTERRANEAN UTILITIES PRIOR TO ANY EXCAVATION.
9.THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED
STRUCTURE AND DO NOT INDICATE METHODS, PROCEDURES OR SEQUENCE OF
CONSTRUCTION. TAKE NECESSARY PRECAUTIONS TO MAINTAIN AND ENSURE THE
INTEGRITY OF THE STRUCTURE DURING CONSTRUCTION. NEITHER THE OWNER NOR
ARCHITECT/ENGINEER WILL ENFORCE SAFETY MEASURES OR REGULATIONS.
CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES,
INCLUDING SHORING AND BRACING, AND SHALL BE SOLELY RESPONSIBLE FOR
CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS,
LAWS AND REGULATIONS.
10.PROPRIETARY COMPONENTS, MATERIALS, CHEMICAL, EPOXY AND WEDGE ANCHORS
AND SHOT PINS SHALL BE EXACTLY AS CALLED FOR IN THESE DRAWINGS. ANY
DEVIATIONS SHALL BE APPROVED OR DISAPPROVED BY THE ENGINEER OF RECORD AT
THE EXPENSE OF THE ENTITY REQUESTING THE SUBSTITUTION PRIOR TO
INSTALLATION.
11.THE CONTRACTOR SHALL BE ULTIMATELY RESPONSIBLE FOR COORDINATION AND
ASSEMBLY OF ALL PARTS OF THE CONSTRUCTION DEPICTED HEREIN. THE
CONTRACTOR SHALL PERFORM ANY CONSTRUCTABILITY REVIEW OR COORDINATION
DRAWINGS NECESSARY TO IDENTIFY CONSTRUCTABILITY PROBLEMS PRIOR TO
CONSTRUCTION.
GEOTECHNICAL NOTES:
GEOTECHNICAL INVESTIGATION: NOVA SERVICES, INC., PROJECT NO. 3024029,
JANUARY 30, 2025.
1.FOUNDATION MATERIAL: APPROVED FILL PER GEOTECHNICAL INVESTIGATION.
2.MINIMUM FOUNDED DEPTH OF FOOTINGS:
BELOW ROUGH PAD GRADE 24"
BELOW LOWEST ADJACENT FINISHED GRADE 24"
3.FOUNDING OF FOOTINGS & SLABS: ON APPROVED COMPACTED SOILS AS NOTED IN
GEOTECHNICAL INVESTIGATION.
CONCRETE AND REINFORCING NOTES (CODE CHAPTER 19):
1.CONTRACTOR TO PROVIDE CONCRETE MIX DESIGNS FROM AN APPROVED
LABORATORY OR FROM THE CONCRETE SUPPLIER PREPARED UNDER THE
SUPERVISION OF, SIGNED, AND SEALED BY A CALIFORNIA REGISTERED ARCHITECT,
CIVIL OR STRUCTURAL ENGINEER.
2.REINFORCEMENT:
A)DETAILING, FABRICATION AND PLACING: SHALL CONFORM TO ACI315 AND ACI318.
CERTIFICATION AND TESTING OF REINFORCING STEEL SHALL BE IN ACCORDANCE
WITH THE PROVISIONS OF ASTM STANDARDS.
B)MINIMUM CONCRETE COVER:
CAST AGAINST & EXPOSED TO EARTH 3"
EXPOSED TO EARTH OR WEATHER 2"
NOT EXPOSED TO WEATHER OR IN CONTACT
WITH GROUND:
SLABS, WALLS, JOISTS 3/4"
BEAMS, COLUMNS (TIES, STIRRUPS, SPIRALS)1-1/2"
C)CHAIRS, SPACERS AND AND PLATES: AS REQUIRED TO MAINTAIN CONCRETE
COVER.
D)VERTICAL REINFORCEMENT: SHALL BE DOWELED TO SUPPORTING MEMBERS WITH
THE SAME SIZE AND SPACING OF REINFORCEMENT AS SHOWN IN THE DRAWINGS
AND GENERAL NOTES.
E)SPACING: CLEAR DISTANCE BETWEEN PARALLEL REINFORCEMENT IN A LAYER
SHALL NOT BE LESS THAN 1-1/2 TIMES THE NOMINAL DIAMETER OF THE
REINFORCEMENT, OR 1-1/3 TIMES MAXIMUM SIZE AGGREGATE, NOR LESS THAN
1-1/2".
F)TACK WELDING, WELDING, HEATING OR CUTTING OF BARS: NOT PERMITTED UON.
G)SPLICES (STANDARD LAPS): AS SCHEDULED, 40 DIAMETERS OR 24 INCHES
WHICHEVER IS GREATER UON ON DRAWINGS. STAGGER BOTTOM SPLICES AT
LEAST 5'-0" FROM SPLICES IN OTHER BOTTOM REINFORCEMENT. STAGGER
SPLICES FOR TOP REINFORCEMENT SIMILARLY.
3.PIPES, SLEEVES AND DUCTS: NOT TO BE PLACED IN WALLS, BEAMS, SLABS, FOOTINGS
OR COLUMNS UNLESS SPECIFICALLY DETAILED.
4.ADMIXTURES: REVIEWED BY THE ENGINEER OF RECORD. CALCIUM CHLORIDE OR
ADDED CHLORIDES ARE NOT PERMITTED. FLY ASH SHALL NOT BE PERMITTED IN
CONCRETE MIXTURES.
5.CONSTRUCTION JOINTS: ACI 360R, 1/4-INCH AMPLITUDE MINIMUM OR KEYED JOINTS
PER PLAN. LOCATION OF JOINTS TO BE REVIEWED BY THE ENGINEER OF RECORD
PRIOR TO PLACEMENT OF REINFORCEMENT.
6.CONCRETE CURING: ACI 302.1R. CONCRETE SHALL BE MAINTAINED IN A MOIST
CONDITION FOR A MINIMUM OF FIVE DAYS AFTER ITS PLACEMENT. FOR CONCRETE
OTHER THAN SLAB ON GRADE, APPROVED CURING COMPOUNDS MAY BE USED IN LIEU
OF MOIST CURING, IF APPROVED BY THE OWNER AND ARCHITECT.
7.VIBRATION: ALL CONCRETE SHALL BE CONSOLIDATED WITH MECHANICAL VIBRATORS
IN ACCORDANCE WITH GENERAL PROVISIONS OUTLINED IN ACI 309R.
REBAR CMU FACE SHELL
CLEAR DIMENSION
RETAINED
EARTH
RETAINING
WALL
℄ DIMENSION
CONSTRUCTION NOTES:
1.REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60.
PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS
GREATER. CENTER VERTICAL BARS IN CELLS, UIO. SEE DETAIL
2.JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD-DRAWN STEEL WIRE
CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES.
3.PROVIDE NORMAL WEIGHT CONCRETE (145 PCF) WITH PROVEN SHRINKAGE
CHARACTERISTICS OF LESS THAN 0.05%, ATTAINING MINIMUM COMPRESSIVE
STRENGTH OF 3,000 PSI AT 28 DAYS.
4.CONCRETE MUST BE CAST DIRECTLY AGAINST UNDISTURBED SOIL, UIO BY SOILS
REPORT.
5. PROVIDE MASONRY UNITS OF MEDIUM WEIGHT CLASSIFICATION COMPLYING WITH
ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST,
WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE-AND-GROOVE), OR ANGELUS
BLOCK SLUMPSTONE SHALL BE USED.
6.MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS
MANUFACTURED BY E-Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS
OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E-Z MIX
INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. MINIMUM
COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE 2000psi.
7.GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A
MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi.
8.FIRST COURSE MAY BE WET-SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC.
9.CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL
CONTINUITY OF THE CELLS U.N.O.
10.VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'-0"o.c.
IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED SEE DETAIL
11.GROUT ALL CELLS WITH REINFORCEMENT U.I.O.
12.INSPECTIONS:
A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED
IN PLACE.
B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR
GROUT.
13.FOR TYPICAL REINFORCING AT WALL INTERSECTIONS SEE DETAIL
14.FOR TYPICAL FOOTING STEP SEE DETAIL
15.FOR TYPICAL DRAINAGE BLOCK-OUT SEE DETAIL
16.CLEAR (CLR.) OR CENTERLINE WHERE REFERENCED TO VERTICAL REINFORCING PER
DETAIL
17.RETAINING WALL BACKFILL SHOULD CONSIST OF SANDY SOILS THAT MUST MEET AT
LEAST ONE OF THE FOLLOWING CRITERIA:
A. A SAND EQUIVALENT (SE) OF 30 OR GREATER PER CALIFORNIA TEST METHOD (CTM)
217, OR
B. A MAXIMUM OF 35 PERCENT FINES (PASSING THE NO. 200 SIEVE) PER AMERICAN
SOCIETY FOR TESTING AND MATERIALS (ASTM) D 421/422 AND AN EXPANSION INDEX
OF 20 OR LESS.
RETAINING WALL BACKFILL SHOULD ALSO BE LIMITED TO FILL MATERIAL NOT
EXCEEDING 3 INCHES IN GREATEST DIMENSION. SEE GEOTECHNICAL INVESTIGATION
FOR ADDITIONAL RECOMMENDATIONS.
18.SEE SOILS REPORT FOR THE HORIZONTAL LIMITS OF SAND BACKFILL REQUIRED.
19. WALLS HAVE NOT BEEN DESIGNED FOR SURCHARGE RESULTING FROM VEHICULAR
TRAFFIC OR ADJACENT FOOTINGS U.I.O.
20. EXCAVATION FOR WALL/ FOUNDATION SHALL NOT UNDERMINE ANY ADJACENT
STRUCTURES. TEMPORARY SHORING AND STABILIZATION OF ADJACENT STRUCTURES
SHALL BE PROVIDED BY THE CONTRACTOR AS REQUIRED
21.FOR TYPICAL PIPE THROUGH FOOTING, SEE DETAIL
1
-
2
-
2
-
5
-
4
-
6
-
1'
-
0
"
MI
N
.
ST
E
P
6"
O
R
8
"
PE
R
C
M
U
BL
K
.
H
T
.
3" CLR.
TYP.
.
1'-0"
STEP
STEPSTEP
CMU WALL PER DETAILS
(TYP. REINF. NOT SHOWN
FOR CLARITY)
ALIGN CONTROL JOINT AT
STEP WHERE OCCURS
40'-0"o.c. MAX.
DOWELS AND DROP-IN BARS
AT CELL EACH SIDE OF STEP
AND CONTROL JOINT TYP.
TOP BARS WHERE
OCURRING
#4 HORIZ. CONT.
w/ 24" MIN. LAP
FINISHED GRADE
FRONT FACE
WALL FOOTING
CHANGE OF WALL
THICKNESS TYP.
CHANGE OF WALL HEIGHT
& FOOTING SIZE TYP.
LAYOUT LINE
MASONRY CAP TYP.
WHERE OCCURRING
EXTEND CAULKING
6" MIN. BELOW FINISH
GRADE TYP.
EXPANSION JOINT
WHERE OCCURRING
PLACE AT 40'-0"o.c. MAX.
EXPANSION JOINT
WHERE OCCURRING
TYPICAL WALL ELEVATION - MASONRY CONSTRUCTION
TYPICAL WALL PLAN - MASONRY CONSTRUCTION
3B
-
TYP.
STRUCTURAL STEEL
1.STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING SPECIFICATIONS.
PLATES AND BARS - ASTM A36, Fy=36 ksi, Fu=58 ksi.
2.FASTENERS FOR STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING
SPECIFICATIONS.
NUTS - ASTM A563.
WASHERS - ASTM F436.
THREADED RODS - ASTM F1554, GRADE 36.
SITE WALLS
STANDARD DETAILS
S-0
DESIGN CRITERIA:
1.DESIGN CRITERIA PER 2022 CBC AND GEOTECHNICAL RECOMENDATIONS
2.ALLOWABLE SOIL BEARING PRESSURE = 2500 PSF (WITH INCREASE PER SOILS REPORT)
3.ALLOWABLE SOIL PASSIVE PRESSURE = 150 PCF
4.COEFFICIENT OF FRICTION = 0.30
5.LEVEL ACTIVE PRESSURE = 45 PCF
6.AT REST PRESSURE = 65 PCF
7.MASONRY COMPRESSIVE STRENGTH, f'm = 2000 PSI. SPECIAL INSPECTION
IS REQUIRED.
LOADING:
1.SEISMIC, 5% DAMPING @ 1 SECOND
ACCELERATION Cs=0.679Wt.
2.DESIGN WIND = EXP. C @ 95 MPH
7
-
PROJECT DESCRIPTION:
OWNER:
ENGINEER OF RECORD:
898 N. FAIR OAKS AVE. STE. F
PASADENA, CA 91103
626.407.2224 GSE JOB #: 25-078
SITE WALLS
THIS DRAWING IS THE SOLE
PROPERTY OF GSE AND IS INTENDED
FOR USE ONLY FOR THE PROJECT
LISTED IN THE TITLE BLOCK. THIS
DOCUMENT AND CONTENTS MAY NOT
BE REPRODUCED, CHANGED OR
COPIED IN ANY FORM OR ASSIGNED
TO ANY THIRD PARTY WITHOUT
WRITTEN PERMISSION BY GSE
SHEET TITLE:
SHEET NUMBER:
DRAWN BY: D.E. HYLTON
PROJECT NUMBER: 25-078
DATE: 04 / 03 / 2025
SO
C
A
L
G
A
S
30
1
E
.
C
O
L
U
M
B
I
N
E
A
V
E
.
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
7
8" CMU WALL 7N.T.S.
MASONRY WALL SYSTEM
FREE-STANDING 8" CMU FENCE WALL
ECCENTRIC FOOTING
9'
-
0
"
MA
X
.
12
"
MI
N
.
12
"
3" CLR.
TYP.
3'-8"
MIN.
8" WIDE (NOM.) CMU.
GROUT CELLS w/ REINF.
DWLS. TO MATCH VERT.
REINF. LAP 24" MIN.
F.G.
WET-SET FIRST COURSE
PER CONSTRUCTION NOTE 8
CONT. CONC. FTG.
#4 VERT. REINF. @16" O.C.
AT CTR. OF WALL
OPTIONAL WALL CAP
#8 STD. LADDER TYPE
(#7 STD. FOR SLUMPSTONE)
REINF. AT TOP COURSE, AT
FIRST COURSE, AND 16" O.C.
#4 CONT. @12" O.C.
STRUCTURAL
CALCULATIONS
SoCal Gas, 301 E Columbine Ave, Site Wall Design
ENGINEER:IVAN GARCIA
STRUC. JOB NO. : 25-078
DATE :4/3/2025
OPERATOR :IVAN GARCIA
PRINCIPAL ENGINEER: Husam Ghanim
These calculations are the property of Husam Ghanim, SE. They are provided to the Building Department as an aid in understanding
the associated drawings. The use of these calculations is restricted to the original use for which they were prepared and their
publication is expressly limited to such use. Reuse, reproduction, or publication, by any method, in whole or part, is prohibited without
the written consent of Husam Ghanim, SE.
Project:SoCal Gas Sheet No:
301 E. Columbine Ave.Project No.:25-078
Santa Ana, CA Date:04/02/25 By:IG
A B C D E F G H I J K L M N
Soil and Wind Series: 62.0002
Occupancy Group -U Exposure C, 95 mph Risk Category - II
SOIL DATA
Geotechnical report:Investigation prepared by Nova Services, Inc., Project No. 3024029, dated January 30, 2025
Bearing:2500 psf 1/3 Increase allowed for wind or seismic loading
Active level backfill:45 pcf
At-rest backfill:65 pcf
Passive:below 12"150 pcf up to a maximum of:1500 psf
Friction:m =0.30
Safety Factors:
Overturning & Sliding (Active):1.5 Retaining walls only
Overturning & Sliding(Seismic):1.1 Retaining walls only
WIND LOADING ASCE 7-16
Section 26.10.2
Velocity pressure qh = 0.00256 x Kz x Kzt x Kd x Ke x V2 ASCE 7 Equation (26.10-1)
Pressure coeff. (26.10.1, T26.10-1)Kz =0.85 0.85 0.85
Topographic factor (26.8.2)Kzt =1.0 1.0 1.0
Dir. coeff. (26.6, T26.6-1)Kd =0.85 0.85 0.85
Ground elev. Factor (26.9, T26.9-1)Ke =1.0 1.0 1.0
3-sec gust wind speed mph V =95 95 95
Section 29.3.1
Wind Load WL = qh x G x Cf x As ASCE 7 Equation (29.3-1)
Net force coefficient (Fig. 29.3-1)Cf =1.40 1.40 1.40
Gust effect factor (26.11)G =0.85 0.85 0.85
Exposure Category C C C
WALL DATA Varying aspect ratios
Horizontal wall dimension ft B =13.33 14.67 16.00
Height of wall ft h =6.67 7.33 8.00
Aspect ratio B/h =2.00 2.00 2.00
Wall area sq.ft.As =1 1 1
Wind pressure (strength level)WL =19.9 19.9 19.9
Wind pressure (service level)WL =11.9 11.9 11.9
lbs/sq.ft.lbs/sq.ft.lbs/sq.ft.
1
Project:SoCal Gas Sheet No:
301 E. Columbine Ave.Project No.:25-078
Santa Ana, CA Date:04/02/25 By:IG
A B C D E F G H I J K L M N
Seismic and Summary Series: 62.0002
FREESTANDING WALL SEISMIC LOADING
Assumptions:Site Class 'D', Ground-supported cantilever walls or fences
MCE, 5% damped @ 1 second S1 =0.456 SD1 =0.841 Ss =1.273 SDS =0.849
Importance factor I =1.0
Response mod. coeff. (T15.4-2)R =1.25
Long-term period. (11.4.5)TL =8 secs
Fundamental period. (15.4-6)Tmin =0.104 secs
Min. seismic load (Cs) min =0.80 x S1 /(R / I) =0.292 (15.4-2)
Min. seismic load (Cs) min =0.044 x SDS x I ≥ 0.03 =0.037 (15.4-1)
Seismic load Cs =SDS /(R / I) =0.679 (12.8-2)
Max. Seismic load (Cs) max =SD1 /(T x R / I) =6.469 Wt (12.8-3)
Cs =0.679 EQ =
Nominal Masonry Unit Width inches 8
Completed Wall Weight - Wt psf Wt Wt Wt
Factored Design - EQ psf S EQ EQ EQ
Reinforcing Spacing - S inches 48 40 27.2 49 33.3
40 41 27.8 53 36.0
32 42 28.5 55 37.4
24 43 29.2 58 39.4
16 47 31.9 63 42.8
SOLID 58 39.4 78 53.0 164 111.4
FREESTANDING LATERAL LOAD SUMMARY
Nominal Masonry Unit Width inches
Strength Design - EQ psf
Strength Design - W psf
48 19.9 27.2 EQ 19.9 33.3 EQ
40 19.9 27.8 EQ 19.9 36.0 EQ
32 19.9 28.5 EQ 19.9 37.4 EQ
24 19.9 29.2 EQ 19.9 39.4 EQ
16 19.9 31.9 EQ 19.9 42.8 EQ
SOLID 19.9 39.4 EQ 19.9 53.0 EQ 19.9 111.4 EQ
16"x16"
EQ Controls W EQ Controls
0.679 x Wt
S W EQ Controls W
6 8
6 16"x16"
2
ASCE Hazards Report
Address:
No Address at This Location
Standard:ASCE/SEI 7-16 Latitude:33.703468
Risk Category:II Longitude:-117.864942
Soil Class:D - Stiff Soil Elevation:43.66687729300932 ft
(NAVD 88)
Wind
Results:
Wind Speed 95 Vmph
10-year MRI 66 Vmph
25-year MRI 72 Vmph
50-year MRI 76 Vmph
100-year MRI 81 Vmph
Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2
Date Accessed: Wed Apr 02 2025
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2.
Page 1 of 3https://ascehazardtool.org/Wed Apr 02 2025
3
SS : 1.273
S1 : 0.456
F a : 1
F v : N/A
SMS : 1.273
SM1 : N/A
SDS : 0.849
SD1 : N/A
T L : 8
PGA : 0.541
PGA M : 0.595
F PGA : 1.1
Ie : 1
C v : 1.355
Seismic
Site Soil Class:
Results:
Data Accessed:
Date Source:
D - Stiff Soil
USGS Seismic Design Maps
Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8.
Wed Apr 02 2025
Page 2 of 3https://ascehazardtool.org/Wed Apr 02 2025
4
The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any
kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or
has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable
sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or
quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation,
relationship, or sponsorship of such third-party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE Hazard Tool.
Page 3 of 3https://ascehazardtool.org/Wed Apr 02 2025
5
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Wind Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
Code References
Calculations per IBC 2021 1807.3, ASCE 7-16
1.00
8.00
0.00
12.00
3,000.0
45.0
0.0
150.0
Criteria Soil Data
Retained Height =ft
Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall
Height of Soil over Toe in
Water table above
=ft =
=
110.00=pcf
=
Soil Density, Heel
=
Passive Pressure =psf/ft
Allow Soil Bearing =psf
Soil Density, Toe 110.00 pcf
Footing||Soil Friction =0.300
Soil height to ignore
for passive pressure =12.00 in
Equivalent Fluid Pressure Method
bottom of footing
Surcharge Loads Adjacent Footing Load
Load Type
0.0 Lateral Load =0.0 #/ft
0.0
0.0
0.0
0.0
Axial Load Applied to Stem
Wall to Ftg CL Dist =0.00 ft
Wind on Exposed Stem psf19.9=
Lateral Load Applied to Stem
Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs
Axial Dead Load
(Strength Level)
=lbs
Footing Type Spread Footing
Surcharge Over Toe
Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft
Used To Resist Sliding & Overturning
Used for Sliding & Overturning
==0.0 ft
Axial Live Load =
Base Above/Below Soil
lbs
=
Axial Load Eccentricity ==Poisson's Ratio 0.300
at Back of Wall
in (Strength Level)
Wind (W)=
6
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Wind Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
Design Summary
Wall Stability Ratios
Overturning =3.02
Global Stability =8.14
OK
Sliding =3.55 OK
Total Bearing Load =1,447 lbs
...resultant ecc.=11.39 in
Eccentricity outside middle third
Soil Pressure @ Toe =1,091 psf OK
Soil Pressure @ Heel =0 psf OK
Allowable =3,000 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe =1,527 psf
ACI Factored @ Heel =0 psf
Footing Shear @ Toe =0.0 psi OK
Footing Shear @ Heel =1.7 psi OK
Allowable =82.2 psi
Sliding Calcs
Lateral Sliding Force =185.5 lbs
less 100% Passive Force
less 100% Friction Force
Added Force Req'd
....for 1.5 Stability =
0.0=
434.1
225.0
==
0.0
-
lbs
lbs
lbs OK
lbs OK
-
Masonry Block Type =
Stem Construction Bottom
Stem OK
Shear.....Actual
Design Height Above Ftg =0.00ft
Wall Material Above "Ht"=Masonry
Thickness =8.00
Rebar Size =#4
Rebar Spacing =16.00
Rebar Placed at =Center
Design Data
fb/FB + fa/Fa =0.336
Total Force @ Section
=lbs
Moment....Actual
=ft-#
Moment.....Allowable =2,397.7
=psi
Shear.....Allowable =80.5psi
Wall Weight =63.0psf
Rebar Depth 'd'=3.81in
Masonry Data
f'm =2,000psiFy=psi 60,000
Solid Grouting =No
Modular Ratio 'n'=16.11
Equiv. Solid Thick.=5.48in
Concrete Data
f'c =psi
Fy =
Masonry Design Method SD=
Load Factors
Building Code
Dead Load 1.200
Live Load 1.600
Earth, H 1.600
Wind, W 1.000
Seismic, E 1.000 psi
Service Level
=195.2lbsStrength Level
Service Level
Strength Level =808.0ft-#
Service Level
Strength Level =4.1psi
Design Method =SD SD SD
Vertical component of active lateral soil pressure IS
NOT considered in the calculation of soil bearing
Anet (Masonry)=47.54in2
7
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Wind Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
0.00
3.67
12.00
Footing Torsion, Tu =
=
ft-lbs0.00
Min. As %
Footing Allow. Torsion, phi Tu
0.0018
=ft-lbs
Footing Data
If torsion exceeds allowable, provide
f'c
0.00
=3,000 psi
Toe Width =ft
Heel Width =
Key Distance from Toe
Key Depth
Key Width =in
=in
=
0.00
0.00
0.00 ft
Footing Thickness =in
3.67=
Cover @ Top =2.00 in@ Btm.=3.00 in
Total Footing Width
=150.00 pcfFooting Concrete Density
Fy =60,000 psi
Footing Design Results
Key:
=
No key defined
Factored Pressure
Mu' : Upward
Mu' : Downward
Mu: Design
Actual 1-Way Shear
Allow 1-Way Shear
Toe:Flush toe condition. No reinforcing required.
phiMn = phi*5*lambda*sqrt(fc)*Sm
=None Spec'd
=
=
=
=
=
1,527
0
0
0
0.00
43.82
Heel:
0
752
1,560
809
1.66
43.82
HeelToe
psf
ft-#
ft-#
ft-#
psi
psi
Heel Reinforcing =None Spec'd
Other Acceptable Sizes & Spacings
Key Reinforcing
Toe Reinforcing =
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
0.95
0.26
#4@ 9.26 in
#5@ 14.35 in
#6@ 20.37 in
in2
in2 /ft
If two layers of horizontal bars:
#4@ 18.52 in
#5@ 28.70 in
#6@ 40.74 in
supplemental design for footing torsion.
phiMn 2,739=
OKOK
Flush toe condition. No reinforcing required.
OK - Flush
8
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Wind Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
Summary of Overturning & Resisting Forces & Moments
.....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment
Item
Force
ft-#lbs ftft ft-#lbs
Sloped Soil Over Heel
=Surcharge over Heel
=
Surcharge Over Heel
=
=
Adjacent Footing Load
=Adjacent Footing Load
Axial Dead Load on Stem =
=* Axial Live Load on Stem
Soil Over Toe
Surcharge Over Toe
Surcharge Over Toe
Load @ Stem Above Soil
=
95.5 6.00 573.1
=
=
=
=
=
Stem Weight(s)
=
567.0 0.33 189.0
Earth @ Stem Transitions
=Footing Weight
=
550.1 1.83 1,008.5
Key Weight
=
Added Lateral Load
lbs
=633.1
Vert. Component
Total
=
1,447.1 1,912.7
* Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation.
Total =R.M.
=185.5 O.T.M.
=
Resisting/Overturning Ratio =3.02
Vertical Loads used for Soil Pressure =1,447.1 lbs
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
Soil Over HL (ab. water tbl)
Soil Over HL (bel. water tbl)
330.0 2.17
2.17
715.1
715.1
Water Table
Buoyant Force =
HL Act Pres (ab water tbl)
HL Act Pres (be water tbl)
90.0 0.67 60.0
Hydrostatic Force
Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 250.0 pci
Horizontal Defl @ Top of Wall (approximate only)0.074 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
9
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Wind Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
Rebar Lap & Embedment Lengths Information
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
K_cover=7.375, K_spacing=16, K_diam=4.5, and K_min=4.5
Lap Splice length for #4 bar specified in this stem design segment (25.4.2.4a) =20.00 in
Development length for #4 bar specified in this stem design segment =12.00 in
Hooked embedment length into footing for #4 bar specified in this stem design segment =5.63 in
As Provided =0.1500 in2/ft
As Required =0.0496 in2/ft
10
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Wind Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
11
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Wind Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
12
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Seismic Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
Code References
Calculations per IBC 2021 1807.3, ASCE 7-16
1.00
8.00
0.00
12.00
4,000.0
45.0
0.0
150.0
Criteria Soil Data
Retained Height =ft
Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall
Height of Soil over Toe in
Water table above
=ft =
=
110.00=pcf
=
Soil Density, Heel
=
Passive Pressure =psf/ft
Allow Soil Bearing =psf
Soil Density, Toe 110.00 pcf
Footing||Soil Friction =0.300
Soil height to ignore
for passive pressure =12.00 in
Equivalent Fluid Pressure Method
bottom of footing
Surcharge Loads Adjacent Footing Load
Load Type
0.0 Lateral Load =0.0 #/ft
0.0
0.0
0.0
0.0
Axial Load Applied to Stem
Wall to Ftg CL Dist =0.00 ft
Wind on Exposed Stem psf0.0=
Lateral Load Applied to Stem
Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs
Axial Dead Load
(Strength Level)
=lbs
Footing Type Spread Footing
Surcharge Over Toe
Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft
Used To Resist Sliding & Overturning
Used for Sliding & Overturning
==0.0 ft
Axial Live Load =
Base Above/Below Soil
lbs
=
Axial Load Eccentricity ==Poisson's Ratio 0.300
at Back of Wall
in (Strength Level)
Seismic (E)=
Stem Weight Seismic Load F lbs=Added seismic base force 269.5/ Wpp 0.679 gWeight Multiplier
13
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Seismic Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
Design Summary
Wall Stability Ratios
Overturning =1.24
Global Stability =8.14
Ratio < 1.5!
Sliding =1.83 OK
Total Bearing Load =1,447 lbs
...resultant ecc.=18.93 in
Eccentricity outside middle third
Soil Pressure @ Toe =3,769 psf OK
Soil Pressure @ Heel =0 psf OK
Allowable =4,000 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe =5,276 psf
ACI Factored @ Heel =0 psf
Footing Shear @ Toe =0.0 psi OK
Footing Shear @ Heel =7.5 psi OK
Allowable =82.2 psi
Sliding Calcs
Lateral Sliding Force =359.5 lbs
less 100% Passive Force
less 100% Friction Force
Added Force Req'd
....for 1.5 Stability =
0.0=
434.1
225.0
==
0.0
-
lbs
lbs
lbs OK
lbs OK
-
Masonry Block Type =
Stem Construction Bottom
Stem OK
Shear.....Actual
Design Height Above Ftg =0.00ft
Wall Material Above "Ht"=Masonry
Thickness =8.00
Rebar Size =#4
Rebar Spacing =16.00
Rebar Placed at =Center
Design Data
fb/FB + fa/Fa =0.727
Total Force @ Section
=lbs
Moment....Actual
=ft-#
Moment.....Allowable =2,397.7
=psi
Shear.....Allowable =80.5psi
Wall Weight =63.0psf
Rebar Depth 'd'=3.81in
Masonry Data
f'm =2,000psiFy=psi 60,000
Solid Grouting =No
Modular Ratio 'n'=16.11
Equiv. Solid Thick.=5.48in
Concrete Data
f'c =psi
Fy =
Masonry Design Method SD=
Load Factors
Building Code
Dead Load 1.200
Live Load 1.600
Earth, H 1.600
Wind, W 1.000
Seismic, E 1.000 psi
Service Level
=421.0lbsStrength Level
Service Level
Strength Level =1,744.5ft-#
Service Level
Strength Level =8.9psi
Design Method =SD SD SD
Vertical component of active lateral soil pressure IS
NOT considered in the calculation of soil bearing
Anet (Masonry)=47.54in2
14
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Seismic Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
0.00
3.67
12.00
Footing Torsion, Tu =
=
ft-lbs0.00
Min. As %
Footing Allow. Torsion, phi Tu
0.0018
=ft-lbs
Footing Data
If torsion exceeds allowable, provide
f'c
0.00
=3,000 psi
Toe Width =ft
Heel Width =
Key Distance from Toe
Key Depth
Key Width =in
=in
=
0.00
0.00
0.00 ft
Footing Thickness =in
3.67=
Cover @ Top =2.00 in@ Btm.=3.00 in
Total Footing Width
=150.00 pcfFooting Concrete Density
Fy =60,000 psi
Footing Design Results
Key:
=
No key defined
Factored Pressure
Mu' : Upward
Mu' : Downward
Mu: Design
Actual 1-Way Shear
Allow 1-Way Shear
Toe:Flush toe condition. No reinforcing required.
phiMn = phi*5*lambda*sqrt(fc)*Sm
=None Spec'd
=
=
=
=
=
5,276
0
0
0
0.00
43.82
Heel:
0
1
1,560
1,559
7.51
43.82
HeelToe
psf
ft-#
ft-#
ft-#
psi
psi
Heel Reinforcing =None Spec'd
Other Acceptable Sizes & Spacings
Key Reinforcing
Toe Reinforcing =
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
0.95
0.26
#4@ 9.26 in
#5@ 14.35 in
#6@ 20.37 in
in2
in2 /ft
If two layers of horizontal bars:
#4@ 18.52 in
#5@ 28.70 in
#6@ 40.74 in
supplemental design for footing torsion.
phiMn 2,739=
OKOK
Flush toe condition. No reinforcing required.
OK - Flush
15
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Seismic Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
Summary of Overturning & Resisting Forces & Moments
.....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment
Item
Force
ft-#lbs ftft ft-#lbs
Sloped Soil Over Heel
=Surcharge over Heel
=
Surcharge Over Heel
=
=
Adjacent Footing Load
=Adjacent Footing Load
Axial Dead Load on Stem =
=* Axial Live Load on Stem
Soil Over Toe
Surcharge Over Toe
Surcharge Over Toe
Load @ Stem Above Soil
=
269.5
=
=
=
=
=
Stem Weight(s)5.50 1,482.2Seismic Stem Self Wt =
567.0 0.33 189.0
Earth @ Stem Transitions
=Footing Weight
=
550.1 1.83 1,008.5
Key Weight
=
Added Lateral Load
lbs
=1,542.2
Vert. Component
Total
=
1,447.1 1,912.7
* Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation.
Total =R.M.
=359.5 O.T.M.
=
Resisting/Overturning Ratio =1.24
Vertical Loads used for Soil Pressure =1,447.1 lbs
If seismic is included, the OTM and sliding ratiosmay be 1.1 per section 1807.2.3 of IBC.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
Soil Over HL (ab. water tbl)
Soil Over HL (bel. water tbl)
330.0 2.17
2.17
715.1
715.1
Water Table
Buoyant Force =
HL Act Pres (ab water tbl)
HL Act Pres (be water tbl)
90.0 0.67 60.0
Hydrostatic Force
Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 250.0 pci
Horizontal Defl @ Top of Wall (approximate only)0.257 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
16
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Seismic Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
Rebar Lap & Embedment Lengths Information
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
K_cover=7.375, K_spacing=16, K_diam=4.5, and K_min=4.5
Lap Splice length for #4 bar specified in this stem design segment (25.4.2.4a) =20.00 in
Development length for #4 bar specified in this stem design segment =12.00 in
Hooked embedment length into footing for #4 bar specified in this stem design segment =5.63 in
As Provided =0.1500 in2/ft
As Required =0.1071 in2/ft
17
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Seismic Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
18
Cantilevered Retaining Wall
LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023
DESCRIPTION:9'-0" Freestanding CMU Wall (Seismic Loading)
Ghanim Structural Engineering
898 N. Fair Oaks Ave
Suite F
Pasadena, CA 91103
(323) 494-3208
www.ghanimse.com
Project File: Freesntanding Wall Design.ec6
Project Title:SoCal Gas
Engineer:IG
Project ID:25-078
Project Descr:Site Walls
19
YES NO
INSTRUCTIONS:
ORAN GE COUNTY FI RE AUTHORI TY
Plan Submittal Criteria
COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects
and RESIDENTIAL TRACT developments
· Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place.
· Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section.
· If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA.
· In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations.
· Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding
requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602.
Address Suite City
Project Scope/Business Description
1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways,
curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within
300 feet of an active or proposed oil well? Fire Master Plan (PR145)
2. Property is adjacent to a wildland area or non-irrigated native vegetation?
Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124)
3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from
an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170)
4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving
private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475)
5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000
sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable
to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless
classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration
or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses
where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories
with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285)
6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card,
button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan
depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520)
7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment;
industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible
liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium
ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations?
Special Equipment Plan (PR315, PR340-PR382)
8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft
maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if
H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240)
9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard
commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330)
10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a
commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335)
Initial each of the following two items indicating that you have read and understand the statement:
11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is
required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed
Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications.
12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located
in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327—
Initials the building department will determine specific requirements.
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name Signature
Phone Number ( ) Date / /
Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA
review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the
applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the
appropriate plans and fees for OCFA review. 10-08-14 EE
COM
301 E Colombine Ave, Santa Ana, CA 92707
4
NEW 8' CMU SITE WALLS TO MATCH EXISTING AT PROPERTY LINES, TO INFILL (E) GAPS AND PROVIDE ADEQUATE SITE SECURITY TO THE FACILITY, 595'-2" TOTAL LENGTH
4
4
4
4
4
4
4
4
4
Keith Muller
619 204-2036
Santa Ana
Docusign Envelope ID: C99609CB-70B9-4C9D-B2A2-FAFC61AEDF27
6/16/2025
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Referral Form
Required for OCFA to review plans upon the request of the Building Department when
the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”.
City / County Official Requesting Review:
City / County Reference #: Date: __________________________________
City / County: _____________________________________ E-Mail: __________________________________
Contact Name: _____________________________________ Phone #: _________________________________
Title: _____________________________________
** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. **
Reason(s) for Review:
Please describe why OCFA Plan Review is or may be required by the City/County :
OCFA COMMENTS:
No further action required on this specific plan type, based
on information provided on: ____/______/______.
Project to be taken in for OCFA Review.
Other:
Name: _________________________________________
Contact #: ______________________________________ Date: _________________________________
OCFA Authorization
Updated: 06/02/2020 rs