Loading...
HomeMy WebLinkAbout2923 W Raymar St #2 - PlanDESIGNED BY: REVISED BY: REVISIONS: DATE:BY: PROJECT: A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN SA N T A A N A , C A 9 2 7 0 4 29 2 3 W R A Y M A R S T R E E T - U N I T # 2 AC C E S S O R Y D W E L L I N G U N I T SANTA ANA, CA 92704 2923 W RAYMAR STREET-UNIT#2 DESIGN ENGINEER: VISAL TE CONSULTANT LIST OWNER: ADDRESS: LEGAL DESCRIPTION & SCOPE OF WORK APN: TRACT NO: LAND USE: ZONING:R-1 SINGLE FAMILY RESIDENCE SCOPE OF WORK: PROJECT INFORMATION OCCUPANCY GROUP: CONSTRUCTION TYPE:VB SPRINKLERED: PLAN SHEET LIST SITE PLAN / PROJECT INFO VICINTY MAP 1. 109-832-19 NO SANTA ANA, CA 92704 2923 W RAYMAR STREET-UNIT #2 SANTA ANA, CA 92704 2923 W RAYMAR STREET ALEJANDRO I & NOHEMI CRUZ ACCESSORY DWELLING UNITS SANTA ANA, CA 92704 2923 W REYMAR STREET HOUSE GARAGE CROSS SECTIONFLOOR PLAN, ROOF PLAN , AND CODE COMPLIANCE: COVER: (E) 1950 SF + (E) 420 SF = 2370 SF LOT AREA: 6000 SF COVERT EXISTING GARAGE (420 SF) TO ADU 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ENERGY CODE (TITLE 24), 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA GREEN BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE, 2 DESIGN ENGINEER: Tel: 323-302-2657 or 626-800-7764 ahaedesigninc.com@yahoo.com INGLEWOOD, CA 90031 833 VICTOR AVE, AHAE DESIGN INC. VISAL TE A-1 A-2 R3 (1 DWELLING UNIT) NUMBER OF STORIES: 1- STORY PROJECT INFO SITE PLAN/ A-1 3915 M.M. 157-17 TO 20 INCL LOT NO: 61BUS STOP MAP (E) DRIVE W AY PROPOSED SITE PLAN SCALE: 1/8" = 1' W RAYMAR STREET (E) MAIN HOUSE COVERT TO ADU (E) GARAGES (E) PRO PERTY LINE 2% SLOPE DRAIN G G-1 SN1 STRUCTURAL NOTES SN2 STRUCTURAL NOTES S1.0 FRAMING PLAN, AND FOUNDATION PLAN T-1 TITLE-24 T-2 TITLE-24 T-3 TITLE-24 A-3 ELEVATIONS PLAN GREEN NOTES - 1 GREEN NOTES 11 3 ' 3 " 62' 0" (E) PRO PERTY LINE (E) PROPERTY LINE 24 ' 0 " 60 ' 0 " 29 ' 3 " 45 ' 0 " 39 ' 0 " 50' 0"6' 0"6' 0" 20' 0" 21 ' 0 " BLOCK WALL (E)WATER HEATER (E) SEWER LINE (E) WATER METER (E) GAS METER 200 AMP. (E) ELECTRIC PANEL (E) PATIO (N) RELOCATED WATER HEATER T-24 CONSULTANT: Tel: 818-484-0495 SUNLAND, CA 91040 10540 JARDIN AVE, ROBEN MARDIROSIAN. approval from Los Angeles County Building and Safety Research Section. for use on existing slabs is required. Any alternative compliance for materials and/or methods requires separate 3. Application of an approved vapor retarder equivalent product (ICC ESR Nos. 1413, 2417, 2785, or 3474) Structure/Foundation. 2. The owner acknowledges possible upgrades are required if there is substantial damage to the Garage below grade and verify existing wood sill plate is located a minimum 8 inches above adjacent grade. 1. Inspector to verify existing continuous footings under exterior walls extends a minimum of 12 inches GARAGE/ACCESSORY STRUCTURE CONVERSION TO ADU NOTES: MAX. ALLOW F.A.R = 35% OR 2100 SF RATIO OF ADU SQ/SFR SQ = 420/1950 = 21.5 % THE HOUSE. 2. 2-WATER HEATERS MUST BE ENCLOSED WITH MATERIAL THAT MATCHES 1. ALL UTILITIES AND ELECTRICAL SERVICES WILL BE UNDERGROUND. NOTES: of the existing residence. Building Safety staff are not responsible for the accuracy of the given "SFR sf" The application is responsible for the given "SFR sf" of the existing primary residence; The ADU sf/ SFD sf ratio is for Park & Rec Fee purpose only. NOTE ON PLAN: (E) SCE EASEMENT 6' 0 " (E) ELECTRIC SUB PANEL (N)) G AS LINE (N) SEWER LINE (N) WATER LINE (1-BED, 1-BATH, 1-LIVING ROOM, 1-KITCHEN, 1-W/D) (N) MINI SPLIT UNIT 100 AMP (N) ELECTRIC PANEL (N) TANKLESS WATER HEATER 2% SLO PE DRAIN 2% SLO PE DRAIN 2% SLO PE DRAIN 2% SLO PE DRAIN G-2 GREEN NOTES - 2 SD1 TYPICAL DETAILS X (NOT IN FLOOD ZONE)FEMA FLOOD ZONE: TO THE MAIN HOUSE (E) WATER LINE 2/2/2025 DIGITAL (CONNECTS TO (E) SERVICE) Bldg# 101121768 APPROVALS: PLNG - CSantana BLDG - CSG Consultants POLICE - BMartin DESIGNED BY: REVISED BY: REVISIONS: DATE:BY: PROJECT: A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN SA N T A A N A , C A 9 2 7 0 4 29 2 3 W R A Y M A R S T R E E T - U N I T # 2 AC C E S S O R Y D W E L L I N G U N I T SANTA ANA, CA 92704 2923 W RAYMAR STREET-UNIT#2 DESIGN ENGINEER: VISAL TE LEGEND Ceiling fixture Wall mounted light C SD Silent toggle switch F Ventilation fan 60 cfm min. with humidistat 30" CLR 24 " C L R 1 1 2 and shall be installed in accordance with NFPA 72 Carbon monoxide hard wired with battery backup and shall be installed in accordance with NFPA 72 Smoke detector hard wired with battery backup G Duplex convenient GFCI outlet, tamper-resistant Duplex convenient AFCI outlet, tamper-resistant (N) 4' X 4' SLIDING WINDOW U-0.3 SHG-0.23 insulated door (N) 3'-0" X 6'-8" exterior door, 0.2. AN NFRC AND SECTION FLOOR PLAN, ROOF PLAN (N) 32" X 6'-8" hollow core interior door 2 (N) 3' X 1'-6" SLIDING WINDOW U-0.3 SHG-0.23 A-2 A-2 15" NFRC window labels to be removed only by owners after final building inspectiond. room without the use of keys, tools or special knowledge (R310.1.1 Emergency escape and rescue openings shall be clear of any obstruction and operational from the inside of the c. opening not greater than 44 inches measured from the floor (R310.2.2). Where a window is provided as the emergency escape and rescue opening, it shall have the bottom of the clear b. minimum net clear opening height of 24 inches and width of 20 inches (R310.2.1). All emergency escape and rescue openings shall have a minimum clear opening of 5.7 square feet with a a. NOTE: SCALE: 1/4" = 1' PROPOSED FLOOR PLAN SCALE: 1/4" = 1'SCALE: 1/4" = 1' 1 HR FIRE WALL STC 50- SOUND WALL 3' 0 " 2' x 6' CLOSET 9' 10" PR O P E R T Y L I N E ( F E N C E ) AND VERTICALLY HORIZONTALLY BLOCKING AT 10'-0" PROVIDE FIRE SEE STRUCTURAL DRAWING MIN 2x4 STOUS AT 24" O.C., BATT INSULATION 3" MIN, EACH SIDE TYPE 'X'GYP, BD. 1 LAYER 5/8" TO JOISTS AT 16" O.C. PERPENDICULAR RESILENET CHANNELS (E) MAIN HOUSE (E) WALL (E) WALL TO BE DEMOLISHED (N) WALL 3' X 6' SHOWER 13 ' 5 " 11 ' 7 " Silent toggle switch with motion sensorV 3' x 3' LANDING 3 sones max. 100 cfm min. Provide kitchen hood R-21 insulation R-15 insulation BEDROOM LIVING ROOM LIVING ROOM BATHROOMKITCHEN BEDROOM IN-FILLED WALL IN-FILLED WALL (FOR ADU) WATER HEATER (N) TANKLESS (N) MINI SPLIT UNIT (N) ELECTRIC PANEL STC 50-SOUND WALL 1HR FIRE WALL W/D Stackable 1 1 2 1 2 2 10' 2" 7' 7 " 3' 6" 20" x 30" ARTIC ACCESS (E) GATE BEDROOM BEDROOM DINING ROOMKITCHEN BATH BATH C SD SD G G G G FV V SCALE: 1/4" = 1' CROSS SECTION R-15 insulation BEDROOMLIVING ROOM R-15 insulation R-21 insulation STC 50- SOUND WALL 1 HR FIRE WALL SCALE: 1/4" = 1' CROSS SECTION TEMP (N) 1 HR FIRE WALL R-15 insulation R-15 insulation PR O P E R T Y L I N E ( F E N C E ) BEDROOM BEDROOM LIVING ROOM (E) MAIN HOUSE BATH BEDROOM BATH KITCHEN DINING ROOM SCALE: 1/4" = 1' EXISTING FLOOR PLAN (E) GATE (E) WINDOW 10' x 4' C A-2 A-A A-2 B-B A-2 C A-2 A-A A-2 B-B A-2 2/2/2025 DIGITAL 100 amp. DESIGNED BY: REVISED BY: REVISIONS: DATE:BY: PROJECT: A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN SA N T A A N A , C A 9 2 7 0 4 29 2 3 W R A Y M A R S T R E E T - U N I T # 2 AC C E S S O R Y D W E L L I N G U N I T SANTA ANA, CA 92704 2923 W RAYMAR STREET-UNIT#2 AND SECTION FLOOR PLAN, ROOF PLAN A-2 A-3 VENTULATION CALCULATION Provided: (4) 12x24 domer vent - cover 576 sq. inches 506 sf/150 = 3.37 sf or 485.76 sq. inches Roof area= 22 x 23 = 506 sf 4:12 SCALE: 1/4" = 1' EAST VIEW SCALE: 1/4" = 1' WEST VIEW SCALE: 1/4" = 1' SOUTH VIEW 8" 7' 4 " 5' 1 " 12" x 24" DOMER VENT SCALE: 1/4" = 1' ROOFVIEW 4:12 2' 8 " 2' 8 " 5' 2 " 4'x4' WINDOW (EGRESS) 4'x4' WINDOW 3'x1'6" WINDOW (E) ROOF 12" x 24" DOMER VENT ASTM D1758 ASPHALT SHINGLE (E) ROOF FORMALEHYDE EMISSION STANDARDS. PARTICLE BOARD, MEDIUM DENSITY FIBERBOAD (MDF) AND HARDWOOD PLYWOOD USED IN INTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW GREEN BUILDING STANDARD CODE, SECTION 4. 504. 4 (VOLOTILE ORGANIC COMPOUND) LIMITS. SEE CALIFORNIA80 PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH VOC DOCUMENTATIONS SHALL BE PROVIDED TO VERIFY THAT COMPLAINT VOC (VOLOTILE ORGANIC COMPOUND) LIMIT FINISH MATERIALS HAVE BEEN USED. MANUALS ARE TO REMAIN WITH THE BUILDING THROUGHOUT THE LIFE CYCLE OF THE STRUCTURE. OPERATION AND MAINTENANCE INSTRUCTIONS FOR ALL EQUIPMENT INSTALLED SHALL BE GIVEN TO OWNER, WITH THE INSTRUCTIONS, THAT THESE CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF CONSTRUCTION AND NOTIFY DESIGNER OF ANY DISCREPANCIES. :GENERAL NOTES 1.8 GALLON/MINUTE KITCHEN FAUCETS AT 60 PSI 1.2 GALLON /MINUTE LAVATORY FAUCETS AT 60 PSI 2.0 GALLON/MINUTE SINGLE SHOWER HEAD AT 80 PSI* 1.28 GALL/FLUSH TOILET 2019 CALIFORNIA BUILDING CODE (SECTION 4.303) ARE: WATER CONSERVING PLUMBING FIXTURES & FITTINGS AS DEFINED BY WATER LINE OF TYPE "L" COPPER ALL PLUMBING FIXTURES SHALL COMPLY TO SENATE BILL 407 PLUMBING REQUIREMENTS ADEQUATE STRAINER SHALL BE INSTALLED. (CPC SEC 608.2) 80 PSI AN APPROVED PRESSURE REGULATOR PROCEEDED BY AN WHERE STATIC PRESSURE IN THE WATER SUPPLY PIPING IS EXCEEDING GENERAL WATER MAIN, WITH AN EXPANSION TANK. CPC SEC. 608.2 & 608.3 PREVENTS DISSIPATION OF BUILDING PRESSURE BACK INTO THE BACKFLOW PREVENTER OR OTHER NORMALLY CLOSED DEVICE THAT PROVIDE WATER SYSTEM WITH A PRESSURE REGULATOR, CHECK VALVE, THAT DOES NOT CAUSE PERSONAL INJURY (CPC SEC. 608.5) INCHES ABOVEGROUND AND POINTING DOWNWARD AND DISCHARGE IN A MANNER BUILDING WITH THE END OF THE PIPE NOT MORE THAN 2’ FEET NOR LESS THAN 6” THROUGH AN AIR GAP INTO THE DRAINAGE SYSTEM OR EXTEND OUTSIDE THE THE RELIEF VALVE OUTLET, SHALL DISCHARGE INDEPENDENTLY BY GRAVITY OR COMBINATION OF BOTH SHALL BE PROVIDED WITH A DRAIN, NOT SMALLER THAN THE DISCHARGE PIPING SERVING A TEMPERATURE RELIEF VALVE, PRESSURE RELIEF 1 CFM WITH A CONTINUOUS OPERATING SYSTEM. CMC TABLE 403.7. SYSTEM CAPABLE OF EXHAUSTING A MINIMUM OF 100 CFM OR 50 RESIDENTIAL KITCHENS SHALL BE PROVIDED WITH AN EXHAUST FROM BUILDING OPENING DAMPER TO DAYLIGHT, VENT CANNOT TERMINATE LESS THAN 3' LOCATION OF ELECTRIC DRYER VENT ON ATTIC, WITH BACKDRAFT MINI-SPLIT UNIT MIN. EACH WAY CONDENSER, PROVIDE A A 3' X 3'X4" CONCRETE PAD W. #4 REBAR 3 DRAIN OR DAY LIGHT STACKED WASHER DRYER, PROVIDE METAL PAN WITH DRAIN TO WALL MOUNTED TANKLESS WATER HEATER. DISH, SHELVES, AND SAFETY GRAB BARS, OR RAILS. (CPC 408.6) PROTRUSIONS OTHER THAN THE VALVE(S), SHOWERHEAD, SOAP ABOVE THE SHOWER DRAIN OUTLET WITH NO DIMENSIONS SHALL BE MAINTAINED TO A POINT OF 70 INCHES ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH CIRCLE, THE MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES AND SHALL SHOWER COMPARTMENT REGARDLESS OF SHAPE, SHALL HAVE A PIECE FIBERGLASS SHOWER/TUB COMBO W/ TEMPERED GLASS. GASKETED TO PREVENT AIR LEAKAGE.” MECHANICAL FASTENERS. THE ATTIC ACCESS DOOR SHALL BE PERMANENTLY ATTACHED CEILING INSULATION USING ADHESIVE OR SHALL BE AT ACCESS ENTRANCE. ATTIC ACCESS DOORS SHALL HAVE LIGHT FOR MAINTENANCE OF EQUIPMENT. CONTROL OF LIGHTS PROVIDE A PERMANENT SWITCH CONTROLLED CLEARANCE 30". ATTIC ACCESS. PROVIDE A 30"x30" MIN. ATTIC ACCESS, MIN. HEAD EACH WAY. LANDING 3'x3' (4" CONCRETE SLAB) WITH#4 REBAR WITH 18" O.C. DOUBLE SINK WITH GARBAGE DISPOSAL. PROVIDE A 30" X 24" CLEAR SPACE IN FRONT OF WATER CLOSE. OWNER TO PROVIDE SHOWER HEAD AND FIXTURES. 3 5 2 6 7 8 NOTE LEGEND 10 4 9 11 12 owners after final building inspection NFRC window labels to be removed only by d. knowledge (R310.1.1 room without the use of keys, tools or special from the inside of the shall be clear of any obstruction and operational Emergency escape and rescue openings c. from the floor (R310.2.2). opening not greater than 44 inches measured have the bottom of the clear emergency escape and rescue opening, it shall Where a window is provided as the b. inches and width of 20 inches (R310.2.1). minimum net clear opening height of 24 feet with a shall have a minimum clear opening of 5.7 square All emergency escape and rescue openings a. NOTE: by Federal Specification HH-I-521E. determined thermal resistance R value of 11 or greater as h. 4. The mineral fiber insulation shall have a resilient channels. kitchen and bathroom areas, if ceilings are on be substituted for carpet and padding in with 1/8" minimum thickness resilient backing may g. 3. Sheet vinyl and linoleum floor coverings shall be as required for fire ratings. or lath and the attachment of channels and gypsum board f. 2. Type and spacing of resilient channels (2.4 pcf). urethane foam (4 pcf), or ½" urethane foam jutted pad, or 48 oz. foam rubber, or 3/8" rebonded e. 13 oz. face wt. carpet (31 oz. tot) and 40 oz. protective guard per Section R312. glazing is more than 18 inches from a degrees from the bottom treadnosing, unless the 60-inch horizontal arc less than 180 than 36 inches above the landing and within a bottom of a stairway where the glazing is less g. Glazing adjacent to the landing at the per Section R308.4.6. the walking surface, or a rail is designed 36 inches or moremeasured horizontally from flights of stairs, and ramps, unless the glazing is surface of stairways, landings between inches above the plane of the adjacent walking where the bottom exposed edge is less than 36 f. Glazing adjacent to stairs and ramps edge of a shower, sauna or steam room. bathtub, or swimming pool, or from the the water’s edge of a hot tub, spa, whirlpool, measured horizontally and in a straight line, from 2. The glazing is within 60 inches, surface. than 60 inches above any standing or walking 1. The bottom edge of the glazing is less where all of the following conditions are present: indoor or outdoor swimming pools, saunas, steam rooms, bathtubs, showers, and containing or facing hot tubs, spas, whirlpools, e. Glazing in walls, enclosures or fences surface. regardless of area or height above a walking baluster panels, and nonstructural in-fill panels, d. Glazing in guards, railings, structural straight line, of the glazing. 36 inches, measured horizontally and in a 4. One or more walking surfaces are within above the floor. 3. The top edge is more than 36 inches above the floor. 2. The bottom edge is less than 18 inches is larger than 9 square feet. 1. The exposed area of an individual pane conditions: operable panel, that meets all of the following c. Window glazing in an individual fixed or in-swinging door. an position and within 24 inches of the hinge side on perpendicular to the plane of the door in a closed 2. Where the glazing is on a wall closed position. a either side of the door in the plane of the door in 1. Where the glazing is within 24 inches of the following conditions: walking surface and it meets either of the edge of the glazing is less than 60 inches above adjacent to a door where the bottom exposed b. Glazing in fixed or operable panels swinging, sliding, and bifold doors. a. Glazing in fixed and operable panels of Section R308: hazardous locations requiring safety glazing per The following shall be considered specific GLAZING NOTES: 2/2/2025 DIGITAL D H F E G H 6 412 D H F F E G H 6 412 S1.0 Sheet Date: Scale: PROJECT: Job Drawn by: Mace Sheet Title BYREVISIONS AS SHOWN 29 2 3 W R A Y M A R S T R E E T AT T A C H E D A C C E S S O R Y D W E L L I N G U N I T SA N T A A N A , C A 9 2 7 0 4 08-17-2024 FOUNDATION AND ROOF FRAMING PLAN LEGENDS INDICATES EXISTING 12" WIDE CONTINUOUS FOOTING INDICATES (E) WALL # L=#'-#" (E) ROOF RAFTERS (NEW) INTERIOR WALL SHALL BE 2X4 @ 16" O.C. HDR.BEAM OR HEADER (FOR HEADER SEE FRAMING LEGENDS) 5 36 4 SHEAR TRANSFER AT EAVES EXISTING 5 8" DIA. ALL THREADED PER PLAN SET IN 3 4" DIA. DEEP DRILLED HOLE IN SIMPSON SET XP EPOXY(ICC-ESR-2508) 'HDU', PER PLAN 2X STUDS @ 16" O.C. OR POST, SIZE PER PLAN AT 'HD' LOCATION SHEAR PLY., WHERE OCCURS, PER PLAN (E) CURB, WHERE OCCURS HOLDOWN TYPE HOLDOWN MAX. ALLOW. LOAD PULL TEST AT 1.6 X ALLOW. LOAD EMBED. DEPTH 'D' EM B E D . DE P T H 'D ' EX I S T I N G ASECTION@INTERIOR WALL EX I S T I N G (E) CONC. SLAB ON GRADE (E) CONT. FTG., TO REMAIN POST PER PLAN E.N., PER PLAN, STAGG. BSECTION@EXTERIOR WALL HOLDOWN AT EXISTING FOOTING 5 8" DIA. ALL THREADED PER PLAN SET IN 3 4" DIA. DEEP DRILLED HOLE IN SIMPSON SET XP EPOXY(ICC-ESR-2508) 7" MIN EMBEDMENT. 'HDU', PER PLAN EXISTING SHEAR TRANSFER AT EXISTING FOOTING EXISTING EX I S T I N G SHEAR PLY., WHERE OCCURS, PER PLAN (E) 2X STUDS @ 16" O.C. (E) CONC. SLAB ON GRADE (E) CONT. FTG., TO REMAIN CONT. 2X BLK'G. W/ 5/8"Ø A.B. PER SHEAR WALL SCHED, SIMPSON 'SET-XP' EPOXY (ICC # ES ESR-2508) (E) FINISH SURFACE, PER ARCH. DWG'S. 7 SHEAR PLY., WHERE OCCURS, PER PLAN E.N., PER PLAN, STAGG. HDR.4x6 DFL. No. 1 PER T-R602.7 FRAMING LEGEND FRAMING NOTES: 1.PROVIDE SINGLE TRIMMER EACH END OF 4X6 OR LESS HEADER OR BEAM & WOOD POST EACH OF 4X8 OR GREATER HEADERS OR BEAM, TYPICAL UNLESS NOTED OTHERWISE. 2.ALL EXTERIOR WALL SHALL BE 2X4 MIN. STUDS @ 16" O.C., UNLESS NOTES OTHERWISE. 3.FOR TYPICAL STUD WALL FRAMING SEE DETAIL 15/SD2 4.PROVIDE MULTIPLE STUDS UNDER MULTIPLE JOISTS, RAFTERS OR TRUSSES. 5.PROVIDE BOUNDARY NAILING ALONG ALL DRAG MEMBERS, UNLESS NOTED OTHERWISE. 6.SEE ARCHITECTURAL PLAN FOR ALL DIMENSIONS AND CONDITIONS NOT SHOWN. 7.ROOFING MATERIAL SHALL NOT EXCEED 8.0 PSF. 8.FASTENERS FOR PRESERVATIVE TREATED AND FIRE-RESISTRDANT-TREATED WOOD SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. THE COATING WEIGHTS FOR ZINC-COATED FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. FASTENERS OTHER THAN NAILS, TIMBER RIVETS WOOD SCREWS AND LAG SCREWS SHALL BE PERMITTED TO BE OF MECHANICALLY DEPOSITED ZINC COATED STEEL WITH COATING WEIGHTS IN ACCORDANCE WITH ASTM B 695, CLASS 55 MINIMUM. 9.GABLE END WALLS SHALL BE BALLOON FRAMED TO ROOF DIAPHRAGM. INDICATES WALL TO BE INFILL TO MATCH EXISTING 8 9 SHEAR WALL NOTATION PER SHEAR WALL SCHEDULE AT SHEET SD1 7" SCALE: 1/4"=1'-0" ATTACHED A.D.U. FOUNDATION PLAN SCALE: 1/4"=1'-0" ATTACHED A.D.U. ROOF FRAMING PLAN 10 12NTSSHEAR TRANSFER AT GABLE END (E) ROOF SHT'G. PER PLAN (E) R.R., PER PLAN (E) B.N., PER PLAN E.N., PER PLAN (E) C.J., PER PLAN (4) - SIMPSON 'SDS' X 3" LONG SCREWS EA. END, TYP. (E) 2X STUDS @ 16" O.C. SIMPSON A35 PER SHEAR WALL SCHED. (16" O.C., MAX.) (E) HDR., WHERE OCCURS (E) 2X STUDS SHEAR PLY., PER PLAN, WHERE OCCURS SIMPSON A35 PER SHEAR WALL SCHED. (16" O.C., MAX.) (E) ROOF SHT'G. (E) R.R. (E) B.N. 2X BLKG AT 32" O.C. W/ (2)-10d, TYP. (E) C.J., PER PLAN (E) HDR., WHERE OCCURS (E) 2X CRIPPLE WALL SHEAR PLY., PER PLAN, WHERE OCCURS SIMPSON A35 PER SHEAR WALL SCHED. (16" O.C., MAX.) (E) ROOF SHT'G. (E) B.N. 2X BLKG AT 32" O.C. W/ (2)-10d, TYP. (E) C.J., PER PLAN E.N. (E) 2X STUDS 2X BLKG AT 48" O.C MAX. 2X BLKG AT 48" O.C. MAX (4) 10d MIN C.J. W/ (2) 16d AT EA. STUD C.J. W/ (2) 16d AT EA. STUD (E) BALLOON FRAME (E) WALL W/ CRIPPLE WALL 2X BLKG AT 48" O.C MAX. (E) R.R. (E) R.R. 2X4 MIN DIAGONAL BRACE AT 48" O.C. CONN. PER NAILING SCHEDULE 1-3/4" MIN. CONT. 2X BLK'G. E.N. FRAMING CONNECTION SHEAR PLY., WHERE OCCURS, PER PLAN SHEAR PLY., WHERE OCCURS, PER PLAN (E) OR (N) B.N., PER PLAN (E) R.R, (E) ROOF SHT'G. SIMPSON 'A35' OR 'LTP4' PER SHEAR WALL SCHED. (16" O.C., MAX.) (E) OR (N) CRIPPLE STUDS @ 16" O.C., HEIGHT VARIES (N) OR (E) 2X BLKG @ 24" O.C. FASTEN W/ 10d, TOP & BOTT. BOTH SIDES CONN., PER SHEAR WALL SCHED. (E) OR (N) B.N., PER PLAN SIMPSON 'A35' OR 'LTP4' PER SHEAR WALL SCHED. (16" O.C., MAX.) E.N. (E) C.J., WHERE OCCURS B.N. E.N. (N) OR (E) 2X STUD WALL NON-BEARING WALL ROOF/CEILING JOISTS PERPENDICULAR TO WALL ROOF/FLOOR SHT'G DTC CLIP AT EACH JOIST TO NON-BEARING WALL BELOW ROOF/CEILING JOISTS PARALLEL WALL 12" GAP 12" GAP 2x4 BLK'G AT 16" O.C. WITH 2-16d EACH SIDE TO JOIST NON-BEARING WALL DTC CLIP AT EACH BLK'G TO NON-BEARING WALL BELOW ROOF/FLOOR SHT'G 0.145"Øx2-1/2" LONG SHOT PINS AT 16"2x PRESSURE TREATED SILL PLATE 0.145"Øx2-1/2" LONG SHOT PINS AT 16"2x PRESSURE TREATED SILL PLATE 1" E M B E D . 1" E M B E D . NON-BEARING WALL ATTACHMENT TO JOISTS 13 14NTS NTS NTS NTS NTS NTS NTS NTS NTS SHEAR PLY., WHERE OCCURS, PER PLAN CONT. P.T. SILL PLATE AND A.B. PER SHEAR WALL SCHED. E.N., PER PLAN 2X STUDS @ 16" O.C. 8" M I N . (E) CONT. FTG., TO REMAIN (E ) (E) STRUCTURAL CURB W/#4 CONT. #3 @ 32" O.C. W/ 3" EPOXY EMBED ROUGHEN JOINT TO 14" AMPLITUDE AND CLEAN SHEAR TRANSFER AT (N) CURB (E) OR (N) CURB WHERE OCCURS. FOR (N) CURB SEE 6/S1.0 4x4 HDU 2 4x4HDU 2 4x4HDU 2 1 L=4'-0" 4x4HDU 2 4x4 HDU 2 6 S1.0 4 S1.0 1 L=6'-0" 4x4HDU 2 4x4 HDU 2 1 L=4'-0" 1 L= 3 ' - 0 " 4x4HDU 2 4 S1.0 4x4 HDU 2 4x4 HDU 2 13 S1.0 TYP. @ NON-BEARING WALL (E) CONC. SLAB ON GRADE, TO REMAIN. PROVIDE REDGARD VAPOR RETARDER ESR- 1413 6 S1.0 3 S1.0 4 S1.0 1 L= 8 ' - 0 " 4 S1.0 4x4 HDU 2 4x4HDU 2 4x4HDU 2 1 L=4'-0" 4x4HDU 2 4x4 HDU 2 8 S1.0 12 S1.0 1 L=6'-0" 4x4HDU 2 4x4 HDU 2 1 L=4'-0" 4x4HDU 2 12 S1.0 9 S1.0 9 S1.0 8 S1.0 (E) R.R.(E) R.R. (E) 2x6 C.J. @ 16" O.C. 13 S1.0 TYP. @ NON-BEARING WALL 3 S1.0 TYP. @ HDU TYP. @ HDU TO (E) FOOTING 9 S1.0 SIM. SIM. 4x4 HDU 2 HDR.HDR. HD R . (E ) R I D G E B O A R D HD R . 4x4HDU 2 1 L= 3 ' - 0 " 1 L= 4 ' - 0 " 1 L= 4 ' - 6 " 1 L=3'-0" 1 L=3'-0"4x4HDU 2 4 S1.0 4 S1.0 1 L= 4 ' - 0 " 1 L= 4 ' - 6 " 1 L=3'-0" 4x4 HDU 2 1 L= 8 ' - 0 " 4x4HDU 2 4x4HDU 2 12 S1.0 12 S1.0 2/2/2025 DIGITAL LOWER/FRAMER PLATE E.N.-50% TO EACH PLATE 2X OR WIDER STUD EDGE NAILING POST W/ HOLDOWN OR STRAP 3X OR WIDER STUD SHEATHING 1 2" MIN. 3 8" MIN. 1 8" MIN. GAP 5 16 " M I N . 1/ 2 " M I N . 5 8" MIN. D 1 1 D/ 4 D/ 6D D D/ 6 2" MI N . 2" MI N . D/ 3 MA X D 10 (2)16d FACENAIL STUD TO HEADER 3XBLK'G TYP. STRAP WHERE OCCURS ON PLAN SEE SHEAR TRANSFER SECTION OR PLAN MIN PLATE SPLICE 4'-0" W/(8) 16d U.N.O. ON PLAN C OFL SUPPORT OUTER 1/3 OF SPAN AT TOP OR BOTTOM MIDDLE 1/3 OF SPAN NO NOTCHES ALLOWED U.N.O. OUTER 1/3 OF SPAN ONLY AT TOP OR BOTTOM NOTCHING OUTER 1/3 OF SPAN (2) HOLES MAX MIDDLE 1/3 OF SPAN NO BORING ALLOWED U.N.O. 2X LARGEST BORE DIA. MIN. NOTE:BEAMS REQUIRING MORE THAN ONE NOTCH MUST HAVE APPROVAL OF THE STRUCTURAL ENGINEER. NOTE: PLACE BORED HOLE @ CENTER OF DEPTH OF BEAM OR JOIST IF POSSIBLE. CONTACT STRUCTURAL ENGINEER FOR EVALUATION OF BORED OR NOTCHED BEAMS OR JOISTS PRIOR TO MODIFICATION OF FRAMING MEMBER. BORING FRACTION OF JOIST D/6 D/3 2X6 2X8 2X10 2X12 2X14 7/8"1-1/8"1-1/2"1-7/8"2-1/8" 1-1/4"2-3/8"3"3-3/4"4-3/8" 40%D MAX. STUD WIDTH NOTCH 60%D MAX. STUD WIDTH BORE NON-BRG. STUDS EXT. & BRG. STUDS 40%D MAX. STUD WIDTH BORE 25%D MAX. STUD WIDTH NOTCH FRACTION OF STUD 25%D 40%D 60%D 2X4 2X6 2X8 7/8"1-3/8"1-7/8" 1-3/8"2-1/8"3" 2"3-1/4"4-1/4" NOTE: NOTCH AND BORE NOT TO OCCUR ON SAME STUD WITHIN 36" OF EACH OTHER ST6224 STRAP @ PLATE BREAK U.N.O. NAIL STRAP W/ 16d SINKER OR 10d COMMON NAILS. APPLY STRAP EQUALLY TO EACH TOP PLATE NOTE:STRAP IS TO BE APPLIED TO TOP OF TOP PLATES.SHIM GAP IN TOP PLATES AS REQ'D. ST6224 STRAP @ PLATE BREAK U.N.O. NAIL STRAP W/ 16d SINKER OR 10d COMMON NAILS. APPLY STRAP EQUALLY TO EACH TOP PLATE NOTE:STRAP IS TO BE APPLIED TO TOP OF TOP PLATES.SHIM GAP IN TOP PLATES AS REQ'D. STUD WALL ST6224 STRAP @ PLATE BREAK U.N.O. NAIL STRAP W/ 16d SINKER OR 10d COMMON NAILS. APPLY STRAP EQUALLY TO EACH TOP PLATE NOTE:STRAP MAY BE APPLIED TO TOP OR FACE OF TOP PLATES. SHIM GAP IN TOP PLATES AS REQ'D. STUD WALL 5 8" MIN. D BORED OR NOTCHED BM. OR JOIST BORED OR NOTCHED STUDS17 13 INTERIOR NON-BEARING STUD WALL FRAMING 14 TOP PLATE BREAK 2 EXTERIOR & INTERIOR BEARING SHEAR WALL FRAMING 15 SHEARWALL AT INTERSECTING WALL 11 BORED OR NOTCHED TOP PLATES SHEAR WALL NAILING12 TOP PLATE SPLICE8 4 16d SHORT NAIL @ 16" O.C. W/(2) MIN. @ EACH BREAK AND MIN. (8) AT EACH SIDE OF UPPER TOP PLATE BREAKS. NAIL FROM BOTTOM AT 3X UPPER TOP PLATE. PROVIDE NAILING AT EACH SIDE OF BREAK IN THE UPPER TOP PLATE AS CALLED FOR ON THE PLANS OR PROVIDE THE ALTERNATE STRAP APPLICATION AS NOTED ON THE PLANS OR AS NOTED IN THE SCHEDULE BELOW. THE NAILS MAY BE INSTALLED IN THE PORTION OF THE TOP PLATES BETWEEN THE UPPER AND THE LOWER BREAK IN THE TOP PLATES. PROVIDE NAILS BETWEEN UPPER AND LOWER TOP PLATE BREAK BREAKOR PROVIDE STRAP ALTERNATE IF LAP LENGTH IS NOT SUFFICIENT FOR PROPER NAILING WITHOUT SPLITTING OF THE PLATE MATERIAL. BREAK IN LOWER PLATE (SPECIAL NAILING NOT REQUIRED) PROVIDE STUD OR CRIPPLE FRAMING AT LOWER BREAKS. STUD WALL PER PLAN BREAK IN TOP PLATE NOTE: NAILING MAY BE PERFORMED FROM THE TOP OR THE BOTTOM OF THE PLATES. NAILING SHOWN IN THIS DETAIL IS INDICATED FROM THE TOP FOR CLARITY OF THE DETAIL INSTRUCTIONS. NAILED SPLICE 16d SHORT NAIL @ 16" O.C. W/(2) MIN. @ EACH BREAK AND MIN. (8) AT EACH SIDE OF UPPER TOP PLATE BREAKS. NAIL FROM BOTTOM AT 3X UPPER TOP PLATE. LAP IN THE PLATES SHALL BE ADEQUATE FOR STRAP AT FACE OF TOP PLATES, OTHERWISE THE TOP APPLICATION IS TO BE USED. ALT:STRAP AT FACE OF PLATES BEYOND BREAKS AT EACH SIDE OF UPPER TOP PLATE BREAK STRAP PER PLAN OR SCHEDULE TO TOP OF PLATES. BREAK IN UPPER TOP PLATES. PROVIDE STRAP EQUALLY TO TOP OF PLATES AT UPPER PLATE BREAK STUD WALL PER PLAN BREAK IN LOWER PLATE (STRAP NOT REQUIRED) PROVIDE STUD OR CRIPPLE FRAMING AT LOWER BREAKS. STRAP SPLICE ALTERNATE PLATE SPLICE SCHEDULE NO.NAILS EACH SIDE OF BREAK ALTERNATE STRAP OPTION 8-16d SHORT NAILS 12-16d SHORT NAILS 16-16d SHORT NAILS 20-16d SHORT NAILS 24-16d SHORT NAILS A B C D E SIMPSON ST18 OR CS16 X 20" LONG CS16 X 26" LONG SIMPSON MSTA36 SIMPSON MSTC28 SIMPSON MSTC40 NOTE:USE 16d SINKER OR 10d COMMON NAILS @ ST STRAPS. PROVIDE FULL NAILING W/ MIN. 2" LONG 8d COMMON NAILS OR 16d SHORT NAILS @ CS16. EDGE NAILING STAGG'D TYP.@ PANEL EDGES SHEARWALL PER PLAN 3 8" MIN. 3 8" MIN. TYP. SHEARWALL PER PLAN SHEATHING STUD AT END OF PANEL- USE 4X POST AT HOLDOWN 1 2" MIN. 3 8" MIN. 1 8" MIN. GAP 3 8" MIN. TYP. 3 8" MIN. SECTION THRU STUDS SHOWING 3X FRAMING @ 2" O.C. E.N. SECTION THRU STUDS SHOWING 2X FRAMING @ GREATER THAN 2" O.C. E.N. 2-2X PLATES @ GREATER THAN 2" O.C. E.N. 2-2X PLATES @ 2" O.C. E.N. UPPER PLATE 4" O.C. @ PLATE TO PLATE STUD WALL PER PLAN E.N.PER PLAN 3 8" M A X . SHEARWALL PER PLAN SHEARWALL PER PLAN 3 8" M A X . 3 8" M I N . 1/ 2 " M I N . SECTION THRU PLTS. SHOWING 2X OR 3X SILL PLATE 3 8" M A X . 5 16 " M I N . 1/ 2 " M I N . (2)16d @ 8" O.C. TYP E.N.TYP.POST PER PLAN (2)16d @ 8"O.C. TYP CORNER W/ POST CORNER W/ POST (2)16d @ 8" O.C. TYP B.N. NAILING TYP CORNER W/O POST INTERIOR W/O POST E.N.TYP. 60%D MAX. STUD WIDTH BORE. PROVIDE MIN.ST-22 OR STRAP PER TOP PLATES SPLICE AT 50% OR LARGER BORED HOLES. PLATE CUT THROUGH FOR PIPE OR VENT SIMPSON FHA SERIES STRAP @ EACH PLATE ON EACH SIDE AT NON- DRAG WALLS ONLY. CONSULT W/ STRUCT. ENGR.FOR EVALUATION PRIOR TO CUTTING TOP PLATES. 40%D MAX. STUD WIDTH NOTCH EXTERIOR & INTERIOR BEARING & NON-BEARING WALLS 3 8" M I N . NOTE:NAIL FHA STRAP W/ (4) 16d SINKER OR SHORT NAILS OR (4) 10d COMMON NAILS AT EACH END. FRACTION OF STUD 40%D 60%D 2X4 2X6 2X8 1-3/8"2-3/8"3" 2"3-1/4"4-1/4" PROVIDE DOUBLE KINGSTUD WHERE OPENING EXCEEDS 6'-0" HEADER PER SCHEDULE U.N.O. ON PLAN(2)20 d FACENAIL THRU ONE PLATE TO STUD* 2x STUDS @ 16" O.C. SEE PLAN 2x BLOCKING @ 4'-0" HEIGHT W/ (2)16d TOENAIL EACH END 2X TRIMMER AND KING STUD PRESSURE TREATED SILL PLATE (2)20d TOE NAIL EA. SIDE OF STUD* TOP OF SLAB OR SHEATHING 3" MIN. 9" MAX. SIMPSON A34 TYP WHERE SHOWN 16d FACENAIL @ 12" O.C. MULTIPLE STUD 5/8"Ø X12" A.B PER SH.W. SCHEDULE OR 4'-0" O.C. MAX (SEE NOTE 3) NOTE: 1.HEADERS, KINGSTUDS AND OTHER REFERENCES ON PLAN GOVERN OVER TYPICAL DETAIL 2.SEE SHEARWALL PLYWOOD NAILING DETAIL FOR ADDITIONAL INFORMATION 3.AT WOOD FRAMED WALLS USE SILL CONNECTION PER SHEARWALL SCHEDULE *: IF SHEAR WALL TYPE IS USING (2)--16d IN LIEU OF (2)--20d NAILS FOR STUD END NAILS. HEADER SCHEDULE (SEE NOTE 1) OPN'G WIDTH HEADER 4x6 4x8 4x10 UP TO 6'-0" 6'-0" TO 8'-0" 8'-0" TO 10'-0" PROVIDE DOUBLE TRIMMER AT OPNG'S GREATER THAN 8'-0", OR IF GREATER THAN 4x8 HEADER SCHEDULE (SEE NOTE 1) OPN'G WIDTH HEADER 4x4 4x6 4x10 UP TO 4'-0" 6'-0" TO 8'-0" 8'-0" TO 10'-0" NOTE: 1.HEADERS, KINGSTUDS AND OTHER REFERENCES ON PLAN GOVERN OVER TYPICAL DETAIL 2.INSTALL 1x6 DIAGONAL LET-IN BRACE AT 25'-0"AND AT EACH END IN ALL WALLS NOT PLYWOOD SHEATHED, MAXIMUM SLOPE OF DIAGONAL SHALL BE 2 VERTICAL TO 1 HORIZONTAL. 3.NAIL SILL PLATE TO WOOD FRAMED FLOORS WITH 16d @ 12" O.C. TO BLOCKING BELOW SHEATHING. SEE NON-BEARING PARTITION ANCHORAGE DETAIL FOR CONNECTION TO FRAMING MIN PLATE SPLICE 4'-0" W/(8) 16d U.N.O. ON PLAN HEADER PER SCHED U.N.O.ON PLAN (2)16 d FACENAIL THRU ONE PLATE TO STUD 2x STUDS @ 16" O.C. SEE PLAN 2x BLOCKING @ 4'-0" HEIGHT W/ (2)16d TOENAIL EACH END 2X TRIMMER AND KING STUD PRESSURE TREATED SILL PLATE TOP OF SLAB OR SHEATHING (2)16d FACE NAIL OR (2)8d TOE NAIL EA. SIDE OF STUD 3" MIN. 9" MAX. SIMPSON A34 TYP WHERE SHOWN 16d FACENAIL @ 18" O.C. MULTIPLE STUD FULL LENGTH 0.145"Ø POWDER DRIVEN ANCHOR W/1 3/8 WASHER AND 1" EMBEDMENT AT 24" O.C. AND 6" FROM END OF PLATE(SEE NOTE 3) (2)16d FACENAIL STUD TO HEADER 16 Sheet Date: Scale: PROJECT: Job Drawn by: Mace Sheet Title BYREVISIONS AS SHOWN 29 2 3 W R A Y M A R S T R E E T AT T A C H E D A C C E S S O R Y D W E L L I N G U N I T SA N T A A N A , C A 9 2 7 0 4 08-17-2024 SD1 TYPICAL DETAILS 7 1 2 3 4 5 NO. PANEL WALL SHEAR W/ 10d COMMON 1/2" STRUCT. 1 PLYWD./OSB PANEL OR 16d 5/8" x 9" LAG SCREWS SIMP. SDS 1/4"Ø x 6" OR FLOOR PLATE FASTERNERS OR 16d 5/8" x 9" LAG SCREWS SIMP. SDS 1/4"Ø x 6" OR FLOOR PLATE FASTERNERS FACE SIDE ONE SIDE ONE SIDE ONE SIDE ONE SIDES TWO SIDES TWO SIDES TWO NAILING @ PANEL EDGE FIELD MEMBER EDGE FASTERNERS SIZE SPACING PLATE SIZE EXTERIOR TYPE SPACING TYPE SPACING INTERIOR FASTERNERS SIZE SPACING 5/8"Ø x 3/4"Ø ANCHORS ANCHOR BOLTS @ SILL PLATE (PLF) SHEAR ALLOWABLE (PLF) SHEAR ALLOWABLE 6" 4" 4" 4" 6" 4" 4" 6" 8" 3" 8" 8" 8" SDPWS-15SDPWS-15 STAGG. 3" STAGG. 2" STAGG. 3" STAGG. 2" 12" 12" 12" 12" 12" 12" 12" MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 4x MIN. 4x 16d SDS 1/4"Ø SDS 1/4"Ø SDS 1/4"Ø SDS 1/4"Ø LAG 5/8"Ø LAG 5/8"Ø MIN. 2x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x LTP4 LTP4 LTP4 LTP4 LTP4 A35 A35 16" 16" 2 SIDES 8" 2 SIDES 8" A35 A35 A35 A35 A35 A35 A35 8" 8" 8" 16" 16" 2 SIDES 8" 2 SIDES 8" 5/8" Ø 5/8" Ø 5/8" Ø 5/8" Ø 5/8" Ø 3/4" Ø 7/8" Ø FOR 2x 32" 32" 16" 16" 16" 16" 16" MIN. 2x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x 340 510 665 870 1020 1330 1740 475 715 930 1217 1430 1860 2435 SHEAR PANEL SCHEDULE SILL PLT. SIZE (SEISMIC)(WIND) 2 1/2" MIN. 2'-0" MIN. 3" CLR. 3" CLR. 1/2" MIN. 2" TO 3" SPACING RAISED FLR. FTG. SLAB FTG. NAILING PATTERN AT PANEL JOINT (FOR 2" AND 3" NAIL SPACINGS) SHEAR PANEL SCHEDULE 1 NOTES: PLYWD. SPLICE 3x BLKG @ EDGE NAILING EDGE NAILING 2 ROWS OF PANEL EDGE 3x STUD @ PLATE 3x BOT. (U.N.O.) 3x BLKG. TOP PLATES CONT. DBL EDGE NAILING 2 ROWS OF PLYWD. SPLICE 3x BLKG @ PLATE 3x BOT. PER PLAN FLOOR JOIST PER PANEL SCH. SILL PLATE W/ A.B. 3x PRESS. TREATED CONT. DBL TOP PLATE 2x STUDS @ 16" O.C. FIELD NAILING 2 ROWS OF EDGE NAILING EDGE NAILING FLOOR JOIST PER PLAN PANEL EDGE 3x STUDS @ EDGE NAILING FIELD NAILING PER PANEL SCH. SILL PLATE W/ A.B. HOLDOWN IF REQ'D PLYWD. PANEL JOINT 3x MIN. @ FLOOR SHEATHING, TYP. U.N.O. PROVIDE MINIMUM 3 IN. PENETRATION INTO MEMBERS BELOW 10. USE 3x AND TREATED SILL PLATE AT CONCRETE SURFACES,TYP.9. ALL NAILS SHALL BE COMMON NAILS, TYP.8. A MINIMUM OF 5d CONCRETE COVER AND 10" MIN. EMBEDMENT. ALL ANCHOR BOLTS AT EDGE OF CONCRETE SHALL HAVE7. ENDS AND EDGES. AND A MINIMUM 1/2" EDGE NAILING DISTANCES AT PANEL OF THE CONNECTING MEMBER FOR SHEAR PANEL PANEL EDGE AND AT LEAST 3/8" FROM THE EDGE NAILS SHALL BE PLACED AT LEAST 3/8" FROM6. USE PLT. 1/4"x3" SQ W/ 5/8" & 3/4" DIA. A.B.5. MORE THAN 1-5/8". COMMON NAILS ARE SPACED 3" O.C. PENETRATE FRAMING EDGES. WHEN NAIL SPACING IS 2" O.C. OR WHEN 10d NAIL SHALL BE STAGGERED IN TWO LINES ALONG PANEL WALL FRAMING TO BE MIN. 3x MEMBER AT PANEL EDGES.4. 3. FOR HOLD DOWN ANCHOR (HD) SEE PLAN & DETIAL PLYWOOD WITH MIN. 5-PLY. ALL PLYWOOD SHEAR PANELS TO BE 1/2" STRUC I2. SEE FRAMING PLANS FOR LOCATION OF SHEAR PANELS1. NO SCALE 6 SHEARWALL SCHEDULE 2/2/2025 DIGITAL FOUNDATION CONCRETE WOODREINFORCING STEELGENERAL G E N E R A L S T R U C T U R A L N O T E S STRUCTURAL DESIGN CRITERIA SHEET INDEX AND STRUCTURAL TEST SPECIAL INSPECTION PROGRAM ADDINATIONAL NOTES Sheet Date: Scale: PROJECT: Job Drawn by: Mace Sheet Title BYREVISIONS AS SHOWN 29 2 3 W R A Y M A R S T R E E T AT T A C H E D A C C E S S O R Y D W E L L I N G U N I T SA N T A A N A , C A 9 2 7 0 4 08-17-2024 EPOXY ANCHORS STRUCTURAL OBSERVATION STRUCTURAL OBSERVATION CONT' DEPUTY INSPECTORS SN1 GENERAL NOTES 2/2/2025 DIGITAL G E N E R A L S T R U C T U R A L N O T E S Sheet Date: Scale: PROJECT: Job Drawn by: Mace Sheet Title BYREVISIONS AS SHOWN 29 2 3 W R A Y M A R S T R E E T AT T A C H E D A C C E S S O R Y D W E L L I N G U N I T SA N T A A N A , C A 9 2 7 0 4 08-17-2024 SN2 GENERAL NOTES 2/2/2025 DIGITAL DESIGNED BY: REVISED BY: REVISIONS: DATE:BY: PROJECT: A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN SA N T A A N A , C A 9 2 7 0 4 29 2 3 W R A Y M A R S T R E E T - U N I T # 2 AC C E S S O R Y D W E L L I N G U N I T SANTA ANA, CA 92704 2923 W RAYMAR STREET-UNIT#2 GREEN NOTES A-2 G 2/2/2025 DIGITAL DESIGNED BY: REVISED BY: REVISIONS: DATE:BY: PROJECT: A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN SA N T A A N A , C A 9 2 7 0 4 29 2 3 W R A Y M A R S T R E E T - U N I T # 2 AC C E S S O R Y D W E L L I N G U N I T SANTA ANA, CA 92704 2923 W RAYMAR STREET-UNIT#2 ENGINEER: VISAL TE DESIGNER: RACHAEL SARIM GREEN NOTES - 1 A-2 G-1 DESIGNED BY: REVISED BY: REVISIONS: DATE:BY: PROJECT: A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN SA N T A A N A , C A 9 2 7 0 4 29 2 3 W R A Y M A R S T R E E T - U N I T # 2 AC C E S S O R Y D W E L L I N G U N I T SANTA ANA, CA 92704 2923 W RAYMAR STREET-UNIT#2 ENGINEER: VISAL TE DESIGNER: RACHAEL SARIM GREEN NOTES - 2 A-2 G-2 T-1 Roben Mardirosian, P.E. 10540 Jardine Ave. Sunland, CA 91040 Tel: (818) 484-0495 Email: roben@armenengineers.com 29 2 3 W . R A Y M A R S T . SA N T A A N A , C A 9 2 7 0 4 ( A D U ) TI T L E - 2 4 R E P O R T DATE: 9/13/24 T- U N I T # 2 Page 330 2022 Building Energy Efficiency Standards Dwelling Unit Floor Area (ft2) >1500 >1000 - 1500 750 - 1000 <750 Table 150.0-G Kitchen Range Hood Airflow Rates (cfm) and ASTM E3087 Capture Efficiency (CE) Ratings According to Dwelling Unit Floor Area and Kitchen Range Fuel Type Hood Over Electric Range 50% CE or 110 cfm 50% CE or 110 cfm 55% CE or 130 cfm 65% CE or 160 cfm Hood Over Natural Gas Range 70% CE or 180 cfm 80% CE or 250 cfm 85% CE or 280 cfm 85% CE or 280 cfm Table 150.0-H Prescriptive Ventilation System Duct Sizing [ASHRAE 62.2:Table 5-3] Fan Airflow Rating, cfm at minimum static pressuref 0.25 in. water (L/s at minimum 62.5 Pa) Minimum Duct Diameter, in. (mm) a,b For Rigid duct Minimum Duct Diameter, in. (mm) a,b For Flex duct c ≤50 (25) 4 e (100) 4 (100) ≤80 (40) 5 (125) 5 (125) ≤100 (50) 5 (125) 6 (150) ≤125 (60) 6 (150) 6 (150) ≤150 (70) 6 (150) 7 (150) ≤175 (85) 7 (180) 7 (180) ≤200 (95) 7 (180) 8 (205) ≤250 (120) 8 (205) 8 (205) ≤350 (165) 9 (230) 9 (230) ≤400 (190) 10 (255) 10 (255) ≤450 (210) 10 (255) NP ≤700 (330) 12 (305) NP ≤800 (380) 12 d (305) NP Footnotes for Table 150.0-H: a. For noncircular ducts, calculate the diameter as four times the cross-sectional area divided by the perimeter. b. NP = application of the prescriptive table is not permitted for this scenario. c. Use of this table for verification of flex duct systems requires flex duct to be fully extended and any flex duct elbows to have a minimum bend radius to duct diameter ratio of 1.0. d. For this scenario, use of elbows is not permitted. e. For this scenario, 4 in. (100 mm) oval duct shall be permitted, provided the minor axis of the oval is greater than or equal to 3 in. (75 mm) f. When a vented range hood utilizes a capture efficiency rating to demonstrate compliance with 150.0(o)1Giiib, a static pressure greater than or equal to 0.25 in. of water at the rating point shall not be required, and the airflow listed in the approved directory corresponding to the compliant capture efficiency rating point shall be applied to Table 150.0-H for determining compliance. Note: Authority: Sections 25213, 25218, 25218.5, 25402 and 25402.1, Public Resources Code. Reference: Sections 25007, 25008, 25218.5, 25310, 25402, 25402.1, 25402.4, 25402.5, 25402.8, and 25943, Public Resources Code. SECTION 150.0 – MANDATORY FEATURES AND DEVICES T-2 Roben Mardirosian, P.E. 10540 Jardine Ave. Sunland, CA 91040 Tel: (818) 484-0495 Email: roben@armenengineers.com 29 2 3 W . R A Y M A R S T . SA N T A A N A , C A 9 2 7 0 4 ( A D U ) TI T L E - 2 4 R E P O R T DATE: 9/13/24 Panasonic Whisper Ceiling Fan FV-0511VQ1 Static Pressure in inches w.g. Air Volume (CFM) Noise (sones) Ventilation Fan Characteristics (HVI Certified data ) Power Consumption (watts) Energy Efficiency (CFM/Watt) Speed (RPM) Current (amps) Power Rating (V/Hz) ENERGY STAR rated 0.1 110 <0.3 10.6 10.6 957 0.18 120/60 YES 0.25 111 0.9 16.4 6.9 1239 0.26 4" 0.1 50 <0.3 4 12.5 756 0.07 120/60 YES 0.25 53 0.4 7.2 7.4 1093 0.13 0.1 80 <0.3 5.9 13.6 821 0.11 120/60 YES 0.25 83 0.6 10.8 7.7 1172 0.18 4"4" T- U N I T # 2 T-3 Roben Mardirosian, P.E. 10540 Jardine Ave. Sunland, CA 91040 Tel: (818) 484-0495 Email: roben@armenengineers.com 29 2 3 W . R A Y M A R S T . SA N T A A N A , C A 9 2 7 0 4 ( A D U ) TI T L E - 2 4 R E P O R T DATE: 9/13/24 T- U N I T # 2 �GECCOORANGE COUNTY FIRE AUTHORIT G, y 7., < Plan Submittal Criteria Form 4,� r cq��f tom! Required for Single Family or Duplex Residences 1HoVLO (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applic Project Information ❑ New Single Family Residence/Duplex ❑ Addition/Remodel ADU CITY OF SANTA ANA Planl ing and Building A jency SFR Approved FOR PERMIT ISSUANCE Certification. Master ID: Date: ❑ Other Address: Unit #: City or Unincorporated County Area: I ZIP: 2923 W RAYMAR STREET - UNIT #2, SANTA ANA, CA 92704 2 SANTA ANA 92704 Scope of Work: Convert existing 420 sq.ft 2-car garage into a new attached ADU with 1-bed, 1-bath, 1-living room, 1-kitchen, 1-W/D. Existing 420 Area to 0 Total Resulting 420 Stories: i I Area Added in Past 2 Years 0 Area: be Added: Area: (excludina this oroiect): Yes No Questionnaire OCFA Plan Type if "Yes" 1. ❑ 0 New — Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability PR400-402 Fire Sprinkler 2. ❑ FO ADU — Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler fire sprinklers or a house that will have firesprinklers added as part of thisproject? 3. ❑ F0 Addition — Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire (PR400-402) Fire Sprinkler sprinkler retrofit based on a threshold set by local ordinance? 4. ❑ FO Distance — Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 140-feet from the fire access roadway? 5. ❑ FO Total Area — Will the addition result in a total area of greater than 3,600 square feet (sf) for non- *(PR160) Residential Site sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all with Water Availability enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? 6. ❑ W1 Remodel — Is this a remodel of a sprinklered building with a scope of work that includes adding or (PR400-402) Fire Sprinkler removing any interior walls? Note: If "Yes", then project must be evaluated by a C-16 licensed contractor to determine if a firesprinkler modification is needed. 7. ❑ F0 Detached Structure — Is this a new detached utility or accessory structure (not an ADU), such as a *(PR160) Residential Site garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold (PR400-402) Fire Sprinkler set by local ordinance? 8. ❑ F0 Gate — Is a gate being installed across a driveway or road that is designated as a fire department (PR180) Gate access roadway, or a driveway or road that serves more than a single home/duplex? 9. ❑ 0 Methane — Is project located in or less than 100' from a "Division of Oil, Gas, and Geothermal *(PR160) Residential Site Resources" (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas *(PR172-174) Methane seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only Test/Mitigation Plans applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU's). 10. ❑ 0 Vegetation — Is the property/structure (A) on the perimeter of a community containing, or adjacent to *(PR125) Fuel Modification slopes or hills, or (B) adjacent to an open space or wildland area containing non -irrigated vegetation, (PR182) Accessory or (C) in a State Responsibility Area or Local Responsibility Area "Fire Hazard Severity Zone", as Structure defined by the State, or D near an area that could be affected by a wildfire in the open space. *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of Cali rnia, that the information above is true: Print Name: SEAN LEWIS Signature: Date: 08/27/2024 Phone Number: 3233022657 Email: SEANALEWIS@AHAEDESIGNSINC.COM Attention Building Department Staff — After you've verified all questions were answered accurately as "No", then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as "Yes", then the plan type on the right side may be required. If all answers are "No" and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are "Yes" and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 APP-13 CBC 2016 NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvem ents specified at ___________________________________________________________________________________________. We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your names as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owne r, obtain the prior approval of the permitting authority. OWNER’S ACKNOWLEGMENT AND VERIFICATION OF INFORMATON DIRECTIONS: Read and initial each statement below to signify you understand or verify this information. _____1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an “Owner -Builder” build- ing permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner’s insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my prop- erty. _____2. I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. _____3. I understand as an “Owner-Builder” I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead o f my own. _____4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbe rs on permits and contracts. _____5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an “employer” under state and federal law. _____6. I understand if I am considered an “employer” under state and Federal law, I must register with the state and federa l government, withhold payroll taxes, provide workers’ compensation disability insurance, and contribute to unemployment com- pensation of each “employee.” I also understand my failure to abide by these laws may subject me to serious financial risk. _____7. I understand under California Contractors’ State License Law, an Owner-Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontrac- tors and the number of structures does not exceed four within any calendar years, or all of the work is performed under contr act with a licensed general building Contractor. _____8. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any finan- cial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workma n- ship or materials. Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org _____9. I understand I may obtain more information regarding my obligations as an “employer” from the Internal Revenue Ser- vice, the United States Small Business Administration, the California Department of Benefit Payments, and the California Divi- sion of Industrial Accidents. I also understand I may contact the California Contractors’ State License Board (CSLB) at 1 -800- 321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. _____10. I am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the following ad- dress:_________________________________________________________________________________________. _____11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner-Builders as well as employers. ____12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the informati on I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors’ State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to underst and that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-Builder and wish to hire Contactors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers’ compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner’s driver’s license, form notariza- tion, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner’s signature. Signature of Property Owner _____________________________________________ Date: ______________________ Print name of Owner __________________________________________________ AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER’S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work):_______________________________________________________ Project Location or Address: ____________________________________________________________________________ Name of Authorized Agent: _____________________________________________________________________________ Address of Authorized Agent:__________________________________________________________________________ Phone Number of Authorized Agent: ______________________________________________________________________ I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Property Owner’s Signature: __________________________________________________ Date:______________________ Print Name of Owner: ______________________________________________________________ Note: A copy of the owner’s driver’s license, form notarization, or other verification acceptable to the agency is re- quired to be presented when the permit is issued to verify the property owner’s signature.