HomeMy WebLinkAbout2726_Strawberry_P0115351_2024-192082_Grading - PlanGBNEB41 GB4DCNG NOTBS· I. ALL GRADING SHALL COMPLY WITH 2010 CBC CHAPTERS 18 AND 33, AND APPENDIX J AND THE SANTA ANA MUNICIPAL CODE. A CITY GRADING PERMIT IS REQUIRED FOR GRADING. 2. GRADING SHALL NOT BE STARTED WITHOUT FIRST NOTIFYING THE CITY GRADING INSPECTOR. A PRE-GRADING MEETING ON THE SITE IS REQUIRED BEFORE STARTING OF GRADING WITH THE FOUOWING PEOPLE PRESENT: GRADING CONTRACTOR, DESIGN CIVIL ENGINEER, GEOTECHNICAL ENGINEER, GRADING INSPECTOR AND WHEN REQUIRED, THE ARCHAEOLOGIST AND PALEONTOLOGIST. THE REQUIRED INSPECTIONS FOR GRADING WILL BE EXPLAINED AT THIS MEETING. 3. AN APPROVED COPY OF THE GRADING PLANS SHALL BE ON THE PERMIITED SITE WHILE WORK IS IN PROGRESS. 4. THE DESIGN CIVIL ENGINEER SHALL BE AVAILABLE DURING THE GRADING TO VERIFY COMPLIANCE WITH THE PLANS, SPECIFICATIONS, CODE AND ANY SPECIAL CONDITIONS OF THE PERMIT WITHIN HIS PURVIEW. 5. THE GEOTECHNICAL ENGINEER SHALL PERFORM PERIODIC INSPECTIONS AND SUBMIT A COMPLETE REPORT AND MAP UPON COMPLETION OF THE ROUGH GRADING. THE COMPACTION REPORT AND APPROVAL FROM THE GEOTECHNICAL ENGINEER SHALL INDICATE THE TYPE OF FIELD TESTING PERFORMED. EACH TEST SHALL BE IDENTIFIED WITH THE METHOD OF OBTAINING THE IN-PLACE DENSITY, WHETHER SAND CONE OR DRIVE RING AND SHALL BE SO NOTED FOR EACH TEST. SUFFICIENT MAXIMUM DENSITY DETERMINATIONS SHALL BE PERFORMED TO VERIFY THE ACCURACY OF THE MAXIMUM DENSITY CURVES BY THE FIELD TECHNICIAN 6. CUT AND FIU SLOPES SHALL BE NO STEEPER THAN 2 FOOT HORIZONTAL TO I FOOT VERTICAL (2:1) EXCEPT WHERE SPECIFICALLY APPROVED OTHERWISE. 7. FILLS SHALL BE COMPACTED THROUGHOUT TO A MINIMUM OF 90% RELATIVE DENSITY AGGREGATE BASE FOR ASPHALTIC AREAS SHALL BE COMPACTED TO MINIMUM OF 95% RELATIVE DENSITY MAXIMUM DENSITY SHALL BE DETERMINED BY UNIFORM BUILDING CODE STANDARD NO. 70-1 OR APPROVED EQUIVALENT. AND FIELD DENSITY BY UNIFORM CODE STANDARD NO. 70-2 ORAPPROVEDEQUIVALENT. 8. THE CONTRACTOR SHALL NOT CREATE ANY TRENCH OR EXCAVATION 5-FEET OR MORE WITHOUT THE NECESSARY PERMIT FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY. 9. ALL CUT SLOPED SHALL BE INVESTIGATED BOTH DURING AND AFTER GRADING BY THE GEOTECHNICAL ENGINEER TO DETERMINE IF ANY SLOPE STABILITY PROBLEM EXISTS. SHOULD EXCAVATION DISCLOSE ANY GEOLOGICAL HAZARDS OR POTENTIAL GEOLOGICAL HAZARDS, THE GEOTECHNICAL ENGINEER SHALL SUBMIT RECOMMENDED TREATMENT TO THE CITY ENGINEER FOR APPROVAL. JO. THE PERMITEE IS RESPONSIBLE FOR DUST CONTROL MEASURES. WATER ACTIVE SITES AT LEAST TWICE DAILY. II. THE LOCATING AND PROTECTION OF ALL EXISTING UTILITIES IS THE RESPONSIBILITY OF THE PERMITTEE. 12. GRADING OPERATIONS INCLUDING MAINTENANCE OF EQUIPMENT WITmN ONE-HALF MILE OF HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:00P.M AND 7:00A.M 13. THE PERMITTEE SHAU GIVE REASONABLE NOTICE TO THE OWNER OF ADJOINING LANDS AND BUILDINGS PRIOR TO BEGINNING EXCAVATIONS WHICH MAY AFFECT THE LATERAL AND SUBJACENT SUPPORT OF THE ADJOINING PROPERTY. THE NOTICE SHALL STATE THE INTENDED DEPTH OF EXCAVATION AND WHEN EXCAVATION COMMENCES. THE ADJOINING OWNER SHALL BE ALLOWED AT LEAST 30 DAYS AND REASONABLE ACCESS ON THE PERMIITED PROPERTY TO PROTECT HIS STRUCTURE, IF HE SO DESIRES, UNLESS OTHERWISE PROTECTED BY LAW. 14. AU EXISTING DRAINAGE COURSES THROUGH THE SITE SHALL REMAIN OPEN TO HANDLE THE STORM WATER; HOWEVER, IN ANY CASE, THE PERMIITEE SHALL BE HELD LIABLE FOR ANY DAMAGE DUE TO OBSTRUCTING NATURAL DRAINAGE PAITERNS. 15. APPROVED EROSION PROTECTION DEVICES SHALL BE PROVIDED AND MAIN'I'AINED DURING THE RAINY SEASON AND SHALL BE IN PLACE AT THE END OF EACH DAY'S WORK. PROPER EROSION CONTROL MEASURES MUST BE SHOWN ON THE PLANS. 16. CONSTRUCTION SITES SHAU BE MAINTAINED IN SUCH A CONDITION THAT AN ANTICIPATED STORM DOES NOT CARRY WASTES OR POLLUTANTS OFF THE SITES. DISCHARGES OF MATERIAL OTHER THAN STORM WATER ARE ALLOWED ONLY WHEN NECESSARY FOR PERFORMANCE AND COMPLETION OF CONSTRUCTION PRACTICES AND WHERE THEY DO NOT: CAUSE OR CONTRIBUTE TO A VIOLATION OF ANY WATER QUALITY STANDARD; CAUSE OR THREATEN TO CAUSE POLLUTION, CONTAMINATION, OR NUISANCE; OR CONTAIN A HAZARDOUS SUBSTANCE IN A QUANTITY REPORTABLE UNDER FEDERAL REGULATIONS 40 CFR Ill AND 302. POTENTIAL POLLUTANTS INCLUDE BUT ARE NOT LIMITED TO: SOLID OR LIQUID CHEMICAL SPILLS; WASTES FROM PAINTS, STAINS, SEALANTS, GLUES, LIMES, PESTICIDES, HERBICIDES, WOOD PRESERVATIVES AND SOLVENTS; ASBESTOS FIBERS, PAINT FLAKES OR STUCCO FRAGMENTS; FUELS, OILS, LUBRICANTS, AND HYDRAULIC RADIATOR OR BAITERY FLUIDS; FERTILIZERS, VEfilCLES/EQUIPMENT WASH WATER AND CONCRETE WASH WATER; CONCRETE, DETERGENT OR FLOATABLE WASTES; WASTES FROM ANY ENGINE/EQUIPMENT STEAM CLEANING OR CHEMICAL DEGREASING; AND SUPERCHLORINATED POTABLE WATER LINE FLUSHJNGS. DURING CONSTRUCTION, DISPOSAL OF SUCH MATERIALS SHOULD OCCUR IN A SPECIFIED AND CONTROUED TEMPORARY AREA ON-SITE, PHYSICALLY SEPARATED FROM POTENTIAL STORM WATER RUN-OFF, WITH ULTIMATE DISPOSAL IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REQUIREMENTS. 17. DEWATERING OF CONTAMINATED GROUNDWATER, OR DISCHARGING CONTAMINATED SOILS VIA SURFACE EROSION IS PROHIBITED. DEWATERING OF NON-CONTAMINATED GROUNDWATER REQUIRES A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM PERMIT FROM THE RESPECTIVE STATE REGIONAL WATER QUALITY CONTROL BOARD. 18. AU DIRT. SAND, MUD, OR DEBRIS DEPOSITED OR SPILLED UPON PUBLIC STREETS DURING ANY GRADING, HAULING, OR EXPORT OPERATIONS SHALL BE IMMEDIATELY CLEANED UP BY THE DEVELOPER, HIS CONTRACTOR, SUBCONTRACTORS, OR AGENTS TO THE SATISFACTION OF THE CITY ENGINEER. FAILURE TO DO SO WIU BE CAUSE FOR STOPPING ALL SUCH GRADING, HAULING, OR EXPORT WORK BY THE CITY UNTIL SUCH TIME AS THE STREETS ARE CLEANED. 19. AU TRUCKS HAULING DIRT. SAND, OIL, OR OTHER LOOSE MATERIALS ARE TO BE COVERED OR SHOULD MAJN'I'AJN A LEAST TWO FEET OF FREEBOARD IN ACCORDANCE WITH THE REQUIREMENTS OF eve SECTION 23ll4. 20. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR OF AU DAMAGES TO PUBLIC PROPERTIES THAT ARE CAUSED BY THE WORK ON-SITE. REPAIR MUST BE COMPLETED TO THE SATISFACTION OF THE CITY ENGINEER. 21. MINIMUM ASPHALT PAVEMENT SECTION SHAU BE: COMMERCIAL AND INDUSTRIAL: PARKING STALLS -3" A.C. OVER 6" A.B DRIVE AISLES-3" A.C. OVER 10" A.B. MULTI-FAMILY.· PARKING STALLS-3" A.C. OVER 4" A.B. DRIVE AISLES-3" A.C. OVER 8" A.B. OR PER THE GEOTECHNICAL REPORT WHEN THICKER SECTION IS REQUIRED. 22. EARTHWORK VOLUMES: CUT.·5CUBIC YARDS FILL: 35CUBIC YARDS NET.· 30CUBIC YARDS SUBMIT HAUL ROUTES FOR APPROVAL IF NET VOLUMES EXCEED 500 CUBIC YARDS. 23. SEPARATE PERMITS MUST BE OBTAINED FROM THE CITY BUILDING AND SAFETY DIVISION FOR THE CONSTRUCTION OF RETAINING WALLS, LIGHT POLES, TRASH ENCLOSURES, ON-SITE PLUMBING AND ALL BUILDING STRUCTURES. ESTIMATE OF EARTHWORK QUANTITIES: CUT-5 C.Y. FILL -35 C.Y. OVEREXCAVATION-30 C.Y. ACREAGE -0.27 ACRE PRIVATE ENGINEER'S. NOTICE TO CONTRACTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THIS PLAN ARE OBTAINED BY A SEARCH OR AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS. ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE PLACE TO WORK AND THE PUBLIC JS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS SHALL COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATION" OF THE U.S. DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS' "CONSTRUCTION SAFETY ORDERS." I .I , I r / '' ' I i / I II :/! I I J I I • /1r---_.,__J I @~&000&@~ ~[s&OO PROPOSED NEW DETACHED ADU DUNG PHAM 2726 STRAWBERY LN, UNIT 2, SANTAANA, CA 92706 CONTRACTOR FURTHER AGREES THAT HE SHAU ASSUME SOLE AND COMPLETE RE-SPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF Tms PROJECT. INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIRE-MENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WOR.KJNG HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNEC-TJON WITH THE PERFORMANCE OF WORK ON THIS PROJECT. EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. I ,:,~,-- en...__ i~' l,,I ,,flJJ ! ~ ~ N0°17'05"W 137.75' IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO EXAMINE THE STAKES BEFORE COMMENCING THE OPERATIONS. SHOULD OCCASION ARISE WHERE THE VALIDITY OF A STAKE JS QUESTIONABLE, EITHER AS TO ITS LOCATION OR THE OFFSET MARKED THEREON, OR AS TO THE ELEVATION OF CUT OR FILL MARKED THEREON. CONTRACTOR SHALL NOTIFY THE ENGINEER WHO WILL CHECK THE STAKE OR STAKES IN QUESTION. ANY STAKES FOUND TO BE IN ERROR WJLLBE RESET WITHOUT CHARGE. IT JS UNDERSTOOD THAT THE ENGINEER WILL NOT BE CHARGED FOR ANY STANDBY OR "DOWN" TIME AS A RESULT OF SUCH CHECKING AND/OR RESEITING PROCEDURE. THE ENGINEER IS NOT LIABLE FOR AUEGED ERRORS WHEN STAKES HAVE BEEN DESTROYED AND FIELD NOTES AND RECORDS INDICATE STAKES WERE SET CORRECTLY. EXACT LAYOUTS OF ALL HARDSCAPE ELEMENTS MAY NEED TO BE MODIFIED AND SOME FIEWADJUSTMENTS MAY BE NECESSARY. THE CONTRACTOR SHALL INCLUDE AS PART OF THE BID, TIME AND LABOR FOR ANY MODIFICATIONS NECESSARY TO IMPLEMENT THE INTENT OF THE DRAWINGS. THE CONTRACTOR IS RESPONIBLE FOR DETERMINING QUANTITIES. THE IMPROVEMENTS AND EARTHWORK QUANTITIES SHOWN HEREON ARE NOT TO BE USED FOR BIDDING OR ESTIMATING. CALIFORNIA COUNCIL OF CIVIL ENGINEER & LAND SURVEYOR CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT. INCLUDING SAFETY OF ALL PERSONS AND PROPERTY.· THAT Tms REQUIREMENT SHAU BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WOR.KJNG HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FORM ANY AND ALL LIABILITY. REAL OR AUE GED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. I I _J-, ~ UNAUTHORIZED CHANGES & USES CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS. NOTES: I-ALL CONSTRUCTION WORK WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE UNDER SEPERATE PERMIT. 2-THE CONTRACTOR SHALL BE FAMILIAR WITH THE PROJECT SOIL REPORT AND ANY SUPPLEMENTS. 3-THE CONTRACTOR JS RESPONSIBLE FOR DETERMINING IMPROVEMENT AND EARTHWORK QUANTITIES. THE IMPROVEMENTS AND EARTHWORK QUANTITIES SHOWN HEREON ARE NOT TO BE USED FOR BIDDING OR ESTIMATING. 4-FOR INFORMATION ONLY. BLOCK WALLS TO BE INSPECTED BY OTHERS UNDER A SEPARATE PERMIT. APPROVAL OF Tms PLAN DOES NOT CONSTITUTE APPROVAL OF THE STRUCTURAL INTEGRITY OF BLOCK WALLS. GENERAL NOTES FOR PUBLIC WORKS PERMITTED WORK ON WAT.ER DISTRIBUTION SYSTEM I. CONSTRUCTION AND INSTALLATION OF ALL WATER MAINS AND APPURTENANCES SHALL BE IN ACCORDANCE WITH THE CITY OF SANTA ANA STANDARD PLANS AND SPECIFICATIONS. WHERE THE STANDARD PLANS ARE SILENT. CONSTRUCTION AND INSTALLATION OF WATER MAINS AND APPURTENANCES SHALL CONFORM TO THE AMERICAN WATER WORKS ASSOCIATION (AWWA) SPECIFICATIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, 2012 EDITION. 2. CONSTRUCTION OF WATER MAINS AND APPURTENANCES SHALL ONLY BE PERFORMED BY QUALIFIED CONTRACTORS WITH A VALID CALIFORNIA CONTRACTOR A OR C34 LICENSE. 3. NO PERSON, OTHER THAN CITY OF SANTAANA WATER RESOURCES DIVISION STAFF CERTIFIED BY THE STATE OF CALIFORNIA AS A WATER DISTRIBUTION OPERATOR, SHALL BE ALLOWED TO OPERATE THE CITY'S WATER SYSTEM VALVES. 4. NO PERSON, OTHER THAN CITY OF SANTAANA WATER RESOURCES DIVISION STAFF CERTIFIED BY THE STATE OF CALIFORNIA AS A WATER DISTRIBUTION OPERATOR, SHALL SHUT WATER SERVICE OFF TO ANY CUSTOMER. 5. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT TO THE CITY FOR REVIEW AND APPROVAL "DISINFECTION AND FLUSHING PLAN" PER THE CITY OF SANTA ANA DESIGN GUIDELINES AND STANDARD DRAWINGS. 6. ALL NEWLY CONSTRUCTED WATER MAINS AND APPURTENANCES SHALL BE DISINFECTED AND TESTED IN ACCORDANCE WITH AMERICAN WATER WORKS ASSOCIATION STANDARD C600'S, PRIOR TO CONNECTING TO THE CITY'S WATER DISTRIBUTION SYSTEM DISINFECTION TESTING RESULTS SHALL BE SUBMIITED TO THE WATER RESOURCES DIVISION FOR REVIEW AND APPROVAL PRIOR TO CONNECTING TO THE CITY'S WATER DISTRIBUTION SYSTEM 7. WATER MAINS WILL BE HYDROSTATIC TESTED AT 200 PSI FOR 2 HOURS. NEW WATER MAINS CANNOT BE TESTED AGAINST AN EXISTING VALVE BUT CAN BE TESTED USING A TEST PLATE. 8. REQUESTS TO SHUT-DOWN THE WATER DISTRIBUTION SYSTEM FOR TIE-INS OR OTHER PURPOSES SHALL BE COORDINATED WITH THE WATER RESOURCES DIVISION STAFF AT LEAST 2 WEEKS IN ADVANCE THROUGH THE CITY INSPECTOR. ALL CUSTOMERS AFFECTED BY THE PROPOSED SHUT DOWN SHALL BE NOTIFIED IN WRITING 48 HOURS IN ADVANCE BY THE CONTRACTOR. 9. THE CITY OF SANTAANA WATER RESOURCES DIVISION CANNOT GUARANTEE A COMPLETE SHUTDOWN OF EXISTING MAINS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DEWATERING AND ISOLATION OF CONSTRUCTION FOR TESTING OR ANY OTHER PURPOSES. 10. ALL FIRE HYDRANTS wmcH ARE OUT OF SERVICE OR NEW FIRE HYDRANTS WHICH HAVE NOT BEEN ACCEPTED FOR SERVICE SHALL BE COVERED WITH A SACK INDICATING THAT THE HYDRANTS ARE NOT IN SERVICE. II. MAINTAINING WATER SERVICE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR FOR ANY SHUTDOWN LASTING LONGER THAN FOUR (4) HOURS. METHOD OF PROVIDING TEMPORARY SERVICE MUST BE APPROVED BY THE WATER RESOURCES DIVISION. THE WATER SHALL BE SAFE FOR DRINKING IN ACCORDANCE WITH STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD (SWRCB} DRINKING WATER PROGRAM (DWP). 12. WATER METER WIU NOT BE INSTALLED NOR WATER TURNED ON UNTIL THE BACKFLOW DEVICES REQUIRED FOR THE BUILDING AND IRRIGATION SYSTEMS HAVE BEEN INSTALLED, TESTED, APPROVED, AND SIGNED OFF BY THE CITY CONTACT WATER RESOURCES DIVISION AT 714 647 3320. 13. ALL WATER MAINS SHALLBEAWWA C-900 PVC, DR14 PIPE ORAWWA C-151 DUCTILE IRON PIPE. ALL OTHER PIPE MATERIALS REQUIRE SPECIAL REVIEW AND APPROVAL FROM WATER RESOURCES DIVISION. 14. WATER MAINS SHALL HAVE 36" MINIMUM COVER TO FINISHED GRADE. ANY DEVIATION FROM TmS REQUIREMENT REQUIRES APPROVAL FROM THE WATER RESOURCES DIVISION. 15. CONTRACTOR TO VERIFY DEPTH AND LOCATION OF ALL UTILITIES AND POINTS OF CONNECTION PRIOR TO TRENCHING. 16. PRIVATE WATER APPURTENANCES SUCH AS BACKFLOW PREVENTERS, FIRE HYDRANTS AND STANDPIPES, AND VALVES SHALL BE PAINTED AS FOUOWS. a. DOMESTIC WATER: BLUE b. POTABLE JRRJGATION: GREEN c. RECYCLED IRRIGATION.· PURPLE d. FIRE PROTECTION: OSHA SAFETY RED 17. DO NOT CUT OR SNAP CUT OR MILL ASBESTOS CEMENT PIPE. WHERE JOINING EXISTING ASBESTOS CEMENT PIPE, EXPOSE SIX FEET IN EACH DIRECTION, LOOKING FOR THE NEAREST JOINT AND JOIN TO NEW PIPE WITH A PROPERLY DIMENSIONED ADAPTER PER STANDARD PLAN NUMBER 1443. INDEX TO PROJECT DRAWINGS SHEETNO. DESCRIPTION I TITLE SHEET. EROSION & HORIZONTAL CONTROL PLAN 2 DRALNAGE PLAN, DETAILS AND SECTIONS EROSION CONTROL NOTES ITEM DESCRIPTION (SE-6) INST.AU TYPICAL GRAVEL BAG PER DETAIL HEREON (WM-8) CONCRETE WASTE MANAGEMENT PER DETAIL HEREON (WM-1) MATERIAL DELIVERY AND STORAGE (WM-) SANITARY WASTE MANAGEMENT (PORTABLE TOILET) INLET PROTECTION PER DETAIL HEREON GENERAL NOTES FOR PUBLIC WORKS PERMITTED WORK ON SEWER COLLECTION SYSTEM I. CONSTRUCTION AND INSTALLATION OF ALL SEWER MAINS AND APPURTENANCES SHALL BE IN ACCORDANCE WITH THE CITY OF SANTA ANA STANDARD PLANS AND SPECIFICATIONS. WHERE THE STANDARD PLANS ARE SILENT. CONSTRUCTION AND INSTALLATION OF SEWER MAINS AND APPURTENANCES SHALL CONFORM TO THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA} SPECIFICATIONS. 2. CONSTRUCTION OF SEWER MAINS AND APPURTENANCES SHALL ONLY BE PERFORMED BY QUALIFIED CONTRACTORS WITH A VALID CALIFORNIA CONTRACTOR A OR C34 LICENSE. 3. ALL NEWLY CONSTRUCTED SEWER MAINS AND APPURTENANCES SHALL BE TESTED IN ACCORDANCE WITH APWA SPECIFICATIONS. ALL NEWLY CONSTRUCTED SEWER MAINS, LATERALS AND MANHOLES MUST BE INSPECTED VIA CLOSED CIRCUIT TELEVISION CAMERA BY A NATIONAL ASSOCIATION OF SEWER SERVICE COMPANIES (NASSCO) CERTIFIED TECHNICIAN AND VIDEO SUBMIITED IN A DIGITAL FORMAT TO THE WATER RESOURCES DIVISION FOR REVIEW AND FINAL ACCEPTANCE OF WORK. 4. ALL SEWER MAINS SHALL BE VITRIFIED CLAY PIPE (VCP) PIPE OR PVC SDR-26 PIPE. ALL OTHER PIPE MATERIALS REQUIRE SPECIAL REVIEW AND APPROVAL FROM THE WATER RESOURCES DIVISION. 5. TRENCH PLATES SHALL BE FLUSH WITH PAVEMENT. 6. CONTRACTOR TO VERIFY DEPTH AND LOCATION OF ALL UTILITIES PRIOR TO TRENCmNG. 7. WHEN PUBLIC SEWER FACJLIDES ARE LOCATED ON PRIVATE PROPERTY. EASEMENT DOCUMENTS ARE TO BE SUBMIITED TO CITY FOR APPROVAL PRIOR TO A PERMIT BEING ISSUED. 8. FINAL ACCEPTANCE WIU NOT OCCUR UNTIL ORIGINAL RECORD DRAWINGS ON MY.UR AND DIGITAL FORMAT ARE DELIVERED TO AND ACCEPTED BY THE CITY'S INSPECTOR. SHOW ALL FIELD CHANGES ON RECORD DRAWINGS. 9. SEWER SYSTEM MANHOLE COVERS AND RINGS REMOVED FROM THE FIELD SHALL BE RETURNED AND DELIVERED TO THE CITY WATER RESOURCES DIVISION YARD LOCATED AT 215 S. CENTER STREET. PRIOR NOTIFICATION OF THE DELIVERY IS REQUIRED AT 714-647-3320. Stockpiled Material 2 GRAVELBAG HIGH MIN. FOR ALL STORM DRAIN INLETS 18. DO NOT TAP EXISTING MAINS WITHOUT THE PRESENCE OF A CERTIFIED PUBLIC WORKS INSPECTOR. PRESSURE TEST TAPPING SLEEVE IN THE PRESENCE OF A CERTIFIED PUBLIC WORKS INSPECTOR BEFORE TAPPING EXISTING MAIN 19. FINAL ACCEPTANCE WILL NOT OCCUR UNTIL ORIGINAL RECORD DRAWINGS ON MYLAR AND DIGITAL FILE ARE DE.LIVERED TO AND ACCEPTED BY THE CITY'S INSPECTOR. SHOW ALL FIELD CHANGES ON RECORD DRAWINGS. 20. TRENCH PLATES SHALL BE FLUSH WITH PAVEMENT AND SHAU BE NON-SKID. GRAVELBAG AT STORM DRAIN INLET 0 N.T.S. 21. WHEN PUBLIC WATER FACILIDES ARE LOCATED ON PRIVATE PROPERTY EASEMENT DOCUMENTS ARE TO BE SUBMIITED TO CITY FOR APPROVAL PRIOR TO A PERMIT BEING ISSUED. 22. ALL RECYCLED WATER PROJECTS REQUIRE REVIEW AND APPROVAL BY THE WATER RESOURCES DIVISION. 23. REMOVE FROM THE FIELD UPPER AND LOWER FIRE HYDRANT DRY BARREL AND 24" X 36" IRON VAULT LID COVERS AND DELIVER UNDAMAGED TO THE CITY WATER RESOURCES DIVISION YARD LOCATED AT 215 S. CENTER STREET. PRIOR NOTIFICATION OF THE DE.LIVERY IS REQUIRED AT 714-647-3320. 24. WATER MAIN FITTINGS SHALL BE FLANGE OR MECHANICAL JOINTS ONLY, NO PUSH-ON JOINT FITTINGS ALLOWED. 25. CONTRACTOR SHALL NOT REMOVE OR DISPOSE EXISTING WATER METERS. CONTRACTOR SHALL APPLY FORAN ABANDON WATER METER APPLICATION. CONTRACTOR SHALL CONTACT WATER RESOURCES DmSION AT 714-647-3320 FOR EXISTING METER REMOVALS. 26. INSTALLATION OF NEW WATER METER SERVICE CURB STOP SHALL BE DONE AFTER INSTALLATION OF NEW CURB AND GUITER OR AFTER CONTRACTOR HAS ESTABLISHED THE PROPOSED CURB GRADE BY STAKING OF THE PROPOSED CURB. ~~;.]_ \~ .--'-.c"-c :-"--·__,, ':.--' <-::/ ,'-;7>,_Y,,, /, Notes: SANDBAGS/GRAVEL BAGS PLACED TJGHI'LY TOGETHER ALL AROUND MATERIAL 1. Dirt and other construction related materials placed in the street or on other impervious surfaces must be contained with sandbags or other measures to prevent transport to the stormdrain system. 2. Any constrnction material stored or stockpiled on-site shall be protected from being transported by the force of wind or water. MATERIAL STORAGE(}) N.T.S. 3" MIN OPENING BETWEEN BAGS TOP ROW E~92~T, SECTION 1-1 R TYPICAL GRAVELBAG DETAIL0 N.T.S. LEGAL DESCRIPTION: TRACT 1351, LOT 32, BOOK 41, PAGE 27 APN: 101-1£-28 Notes: CONCRETE WASHOUT AREA 1. Excess and wmte concrete shall not be washed into the street or into a drainage system. 2. For washout of concrete and mortar products, a desig1Jated containment facility of sufficient capacity to retain liquid mid solid waste shall be provided on site. 3. Slurry from concrete and asphalt saw cutting shall be vacuumed or contained, dried, picked up and disposed of properly. CONCRETE WASTE MANAGEMENT (}) N.T.S. FOR PUBLIC SEWER AND WATER FACILITIES ONLY APPROVED BY.· CESARE. BARERRA P.E. DEPUTY PUBLIC WORKS DIRECTOR/ WATER RESOURCES MANAGER DATE 24.5' !;; ~ is >,; ~ ~ "' ~ VICINITY MAP NTS 2 .8' 15.5' •.•. t •.•. I . •.• I -: -: t • .•. I .•.• I . •.• I ,~rn-• -I TRADKAVE ;;i HUCKLEBERRY RD >,; ~ ::i ~ ~ STRAWBERY LN • .... "' PROJECT "- SITE ! "' WESTMINSTER ST Underground Service Alert BENCH MARK REVISIONS DEVELOPER/OWNER SOILS ENGINEER APPROVED BY, DRAWN BY, KN 08/2024 TITLE SHEET, EROSION & nss, DESIGNED BY, LP 08/2024 JC-ll6-69: 95.809 (NAVD88 2005) LY PHAN --\ p 1-f REV. DATE BY DESCRIPTION APP'V'D BUILDING DEPT. CHECKED BY, BT 08/2024 HORIZONTAL CONTROL PLAN APPROVED BY: P.E. PREPARED UNDER THE SUPERV1SION OF: ~ ",oRc reu sc~" 1 w Call: TOLL FREE i u (~ "' 1-800-422-4133 -MONUMENT IS LOCATED IN THE NORTHWESTER.LY CORNER OF THE INTERSECTION OF WESTMINSTER BOULEVARD AND FAIRVIEW ROAD, 112 FT. NORTHERLY OF THE CENT.ERLINE OF WESTMINSTER BOULEVARD AND 45 FT. WESTER.LY OF THE CENT.ERLINE OF FAIRVIEW ROAD. MONUMENT JS SET LEVEL WITH THE SIDEWALK DUNGPHAM TMC ENGINEERS INC. 2726 STRAWBERY LN TIENCHU,PE SANTA ANA, CA 92706 RCA 72324, EXP. 6-30-2026 7/4-856-212/ 9542 PACIFIC AVE, ANAHEIM, CA 92804 RCE63381 No. C63381 EXP. 9-30-2026 DUNG PHAM PLANNING DEPT. 10082 EMERSON AVE ~ APPROVED BY, IV\\. GARDEN GROVE, CA 928 2726 STRAWBERY LN, UNIT 2 -TEL. (714) 829-5053 TWO WORKtNG DAYS BEFORE YOU DIG PUBLIC WORKS DIRECTOR TEL. (714) 548-1233 SANTA ANA, CA 92706 R.C.E. NO., EXP. DATE, EMAILLYJ0@GMAIL.COM R.C.E. NO., 633B1 EXP. DATE, 9/30/2026 .... "' I,:, !:::1 "' ~ :a,; SHEET 1 OF 2 for 12/12/24 Behrooz Sarlak 3/7/2025 ~ PROPOSED ELEVATIONS ~ EXISTING ELEVATIONS PROPERTY LINE -E-ELECTRICAL LINE -x-CHAIN LINK FENCE -RW-RECLAIMED WATER -s-SEWER LINE -T-TELEPHONE LINE -w-WATER LINE BLOCK WALL &. ~ EDGE OF PAVEMENT / / / EXISTING BUILDING AC ASPHAL TIC CONCRETE .. DRAINAGE DIRECTION P<·>,'I A.C. c::;::J CONCRETE C8J WATER METER KEYNOTES (PROTECT IN PLACE) ITEM DESCRIPTION 0 PROTECT IN PLACE EXISTING CURB AND GUTTER 0 PROTECT IN PLACE EXISTING POWER POLE 0 PROTECT IN PLACE EXISTING DRIVEWAY APPROACH 0 PROTECT IN PLACE EXISTING LANDSCAPE AREA & TREE 0 PROTECT IN PLACE EXISTING BLOCKWALIJFENCE 0 PROTECT IN PLACE EXISTING CONCRETE DRIVEWAY 0 PROTECT IN PLACE EXISTING CONCRETE WALKWAY LEGEND BSW BACK OF SIDEWALK INV INVERT CL CENTERLINE IRRBOX IRRIGATION BOX co CLEAN OUT LF LINEAR FEET CONG CONCRETE LS LUMP SUM CP SURVEY CONTROL POINT LT LIGHT DCK TOP OF DECK OG ORIGINAL GROUND DWNSPT DOWN SPOUT POC POINT OF CONNECTION EG EXISTING GRADE PS PIPE SLOPE EP EDGE OF PAVEMENT SF SQUARE FEET FF FINISHED FLOOR SGN SIGN FG FINISHED GRADE TC TOP OF CURB FH FIRE HYDRANT TCW TOP CONG. WALL FL FLOW LINE TG TOP GRATE FTG TOP OF FOOTING TP TOP OF PIPE FS FINISHED SURF ACE TR TOP OF RAIL GB GRADE BREAK TOR TOP OF RAMP GM GAS METER WV WATER VALVE HP HIGH POINT ~ LANDSCAPED AREA i SURF ACE FLOW DIRECTION . -tOt FIRE HYRANT ~ PORCH e l2ZJ NEW AC EXISTING TREE CONSTRUCTION NOTES -EST/MA TED QUANTITIES * * * ITEM DESCRIPTION ON-SITE OFF-SITE CD CONSTRUCT DRAIN BOX INLET PER DETAIL HEREON 3EACH 0 INSTALL CURB DRAIN WITH 3-112" SCH 60 PVC PIPE !EACH PER CJTYOF SANTAANA STD. 319 (n=l) 0 INSTALL CLEAN-OUT PER CITY STD. 1204 2EACH 0 INSTALL DOWNSPOUT PER DE'I'AJL HEREON 3EACH CD NEW LANDSCAPE AREA 1,200SF 0 ETCH A "W" ON THE CURB FACE TO DENOTE THE WATER METER 2EACH (!) ETCH A "S" ON THE CURB FACE TO DENOTE THE EXISTING !EACH SEWER LATERAL ® REMOVE EXISTING CONCRETE AREA 800SF 0 CONSTRUCT NEW 4" CONCRETE WALKWAY 650SF @ REMOVE & REPLACE CONCRETE AREA 290SF ® REMOVE EXISTING SHED 4EACH @ INSTALL 3" PVC DRAINAGE PILE 90LF @ CONSTRUCT NEW V-GUTTER PER DETAIL HEREON£ 19LF * THE FOUOWING ITEMS REQUIRE A SEPERATE PUBUC WORKS ENCROACHMEm PERMIT: 0 0 0 P!L P!L 10' & Var 0 "' P/L 12' & Var 0 3' 0 6"MIN 3' 0 FL PERPLAN "MIN GRADING LTMIT 20.5' (N) UNIT#2 F.F.=97.09 PAD=96.42 UPACTED SUBGRADE SECTION A-A N.T.S. 3' 12.5' 0 0 "~ 611 MIN "'"' ~ GRADING UMIT 40.8' 4' (N) UNJT#2 0 FL ERP F.F.=97.09 6" MIN l% 2% +-l=~=========='"PA;;;D;,,,=,,;9;;6.4;;;2;.,.,.,===="====.½ES<I -+ l% 2% ¥1!!._ !1!l!-:~:i_:'._~~•:9f1/t .. ~·~-?:~:,,~j~;:v~<~;::,y,~\\;:s:t\!'.~,~:\:Y#=:?:~\~¥,~>~~-~-'.~~0?,;-~,_~~:~~,1·.,:·;,;?:,~~(:··· "· -: , ··---:: '_~_·;_ •• _>l-:-· .... ., ,_ Yf&_ .NI!!- • :: t\f 0:.~«(«(«(«(«(«(~~ AC % % ~«(«(~ J;:_)'. :;::>,',;"-»"-»'\:/.»: >'>-Y>-»"-»~ >'>-Y>-Y>->; 'A..V..~ CTED SUBGRAD SECTIONB-B NT.S. Underground Service Alert ~ «,oRc reu BENCH MARK REVISIONS DEVELOPER/OWNER sc~" 1 w Call: TOLL FREE i u (~ "' 1-800-422-4133 -- TWO WORKING DAYS BEFORE YOU DIG REV. DATE BY DESCRIPTION APP'V"D JC-116-69: 95.809 (NAVD88 2005) MONUMENT TS LOCATED IN THE NORTHWESTERLY CORNER 0Ff---+----+--+----------+----, THE INTERSECTION OF WESTMINSTER BOULEVARD AND FAJRv.TEW ROAD, 112 FT. NORTHERLY OF THE CENT.ERLTNE OF WESTMINSTER BOULEVARD AND 45 FT. WESTERLY OF THE CENT.ERLTNE OF FA/Rv.TEW ROAD. MONUMENT JS SET LEVEL WITH THE SIDEWALK. DUNGPHAM 2726 STRAWBERY LN SANTA ANA, CA 92706 714-856-2121 T.G. ELEV. (SEEPLAN) REDUCE PIPERIS 10 ! GRAPHIC SCALE 5 0 10 ·~~1 ! SCAI.E: IN f'E:E:1 I inc/I = 10 II. SPEED-D-TUFF GRATE N.D.S. No. 1212 (GREEN) 1-.---1¥---1; ORAPPROVEDEQUAL F.G. GRATE HOUSING ADDAPTER N.D.S. No. 1212 OR APPROVED EQUAL 3"PVC •~:··-------- NOTE: FOR BINDING A.B.S. TOP. V.C. CONTRACTOR TO USE WEW­ ON 194SOLVENTOREQUAL ~--Y_J.-~ TNV. ELEV. (SEEPLAN) DETAIL(}) NT.S. GUT.TER DRAIN DOWNSPOUT DETAIL 0 N.T.S. FLPERPLAN -------t~ 12" 7 4" so/o _..::,;.--: V-GUTTER DETAIL 0) N.T.S. SOILS ENGINEER TMC ENGINEERS INC. TIENCHU,PE RCA 72324, EXP. 6-30-2026 9542 PACIFIC Av.E, ANAHEIM, CA 92804 TEL. (714) 829-5053 I DRAINAGE PLAN STANDARD SEWER NOTES: 1. CONSTRUCTION AND INSTALLATION OF AU SEWER MAINS AND APPURTENANCES SHALL BE IN ACCORDANCE WITH THE CJTY OF SANTA ANA STANDARD PLANS AND SPECIFICATIONS. WHERE THE STANDARD PLANS ARE SILENT. CONSTRUCTION AND INSTALLATION OF SEWER MAINS AND APPURTENANCES SHALL CONFORM TO THE STANDARD SPECIFICATIONS FOR PUBUC WORKS CONSTRUCTION, 2012 EDITION. 2. CONSTRUCTION OF SEWER MAINS AND APPURTENANCES SHALL ONLY BE PERFORMED BY QUAUFIED comRACTORS WITH A VALTD CALIFORNIA CONTRACTOR A OR C34UCENSE. 3. ALL NEWLY CONSTRUCTED SEWER MAINS AND APPURTENANCES SHALL BE TESTED IN ACCORDANCE WJTH THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. ALL NEWLY CONSTRUCTED SEWER MAINS, LATERALS AND MANHOLES MUST BE INSPECTED VIA CLOSED CIRCUIT TELEVISION CAMERA BY A NATIONAL ASSOCIATION OF SEWER SERVICES COMPANIES (NASSCO) CERTIFIED TECHNICIAN AND VIDEO SUBMIT.TED IN A DTGJTAL FORMAT TO THE WATER RESOURCES DIVTSION FOR REVIEW AND FTNALACCEPTANCE OF WORK. 4. ALL SEWER MAINS SHALL BE VITRIFIED CLAY PIPE (VCP) OR PVC SDR-26 PIPE. ALL OTHER PIPE MATERIALS REQUIRE SPECIAL REVIEW AND APPROVAL FROM THE WATER RESOURCES DIVISION. 5. TRENCH PLATES SHALL BE FLUSH WITH PAVEMENT AND SHALL BE NON-SKTD. 6. comRACTOR TO VERIFY DEPTH AND LOCATION OF ALL UTIUTIES AND POINTS OF CONNECTION PRIOR TO TRENCHING. 7. WHEN PUBLIC SEWER FACTLTTIESARE LOCATED ON PRIVATE PROPERTY, EASEMEm DOCUMENTS ARE TO BE SUBMIT.TED TO CITY FOR APPROVAL PRIOR TO A PERMIT BEING ISSUED. 8. FINAL ACCEPTANCE WILL NOT OCCUR umIL ORIGINAL RECORD DRAWINGS ON MYLAR AND DIGJTAL FORMAT ARE DELiv.ERED TO AND ACCEPTED BY THE CITY S INSPECTOR. SHOW ALL FIELD CHANGES ON RECORD DRAWINGS. 9. ALL SEWER REPAIRS SHALL BE ACCOMPLISHED USING STAINLESS STEEL DOUBLE BANDED COUPLINGS. APPROVED BY: nss, BUILDING DEPT. LY PHAN '\ Pff APPROVED BY: P.E. RCE63381 No. C63381 PLANNING DEPT. EXP. 9-30-2026 APPROVED BY: 10082 EMERSON AVE GARDEN GROVE, CA 928 IV\\. PUBLIC WORKS DIRECTOR R.C.E. NO.: EXP. DATE: TEL. (714) 548-1233 EMAILLYJ0@GMAIL.COM DRAWN BY: SEWER AND WATER CONSTRUCTION NOTES: ®-PROTECT IN PLACE EXISTING 4" SEWER LATERAL. @-PROTECT IN PLACE EXISTING 5/8" WATER METER CONSTRUCT 1" WATER SERVICE WITH 3/4" METER PER STANDARD PLAN NO. 1401 FOR DOMESTIC USE. WATER METER TO BE INSTALLED BY CITY FORCES AFTER SUBMISSION OF A WATER METER APPUCATION AND PAYMENT OF FEES. comACT THE WATER RESOURCES DIVTSION AT 714-647-3320 FOR ASSISTANCE. PAVEMEm RESTORATION PER STANDARD PLAN NO. 1150. SIDEWALK RESTORATION PER CITY STD PLAN NO. /104 PRESSURE REDUCING VALVE NOTES: INDIVIDUAL PRESSURE REGULATORS ARE REQUIRED BY THE UNIFORM PLUMBING CODE IF THE AVERAGE STATIC PRESSURE IN THE PUBLIC WATER MAIN IS 80 PSI OR MORE. WHERE REQUIRED, THE WATER SERVICE SHALL BE PROVIDED WITH APPROVED PRESSURE REGULATORS SET ATB0 PSI AND SHALL BE INSTAUED PER CITY OF SANTA ANA'S STANDARD PLANS OR APPROPRIATE GOVERNING AGENCY'S STANDARDS. PRESSURE REGULATORS SHALL BE INSTALLED ON PRIVATE PROPERTY AND SHALL BE MAimAINED BY THE PROPERTY OWNER. (COmACTWATER QUALTTY INSPECTORAT(714) 647-3341 FOR PRESSURE REDUCING VALVES QUESTIONS/CONCERNS) KN 08/2024 DESIGNED BY: LP OB/2024 DRAINAGE PLANS & DETAILS CHECKED BY: BT 08/2024 PREPARED UNDER THE SUPERV1SION OF: DUNG PHAM ~ 2726 STRAWBERY LN, UNIT 2 SANTA ANA, CA 92706 R.C.E. NO.: 63381 EXP. DATE, 9/30/2026 5 SHEET 2 OF 2 Behrooz Sarlak 3/7/2025