A1
<br />SHEET:
<br />SCALE:
<br />DATE:
<br />04/15/2025
<br />GENERAL NOTES
<br />1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, GRADES, AND SITE CONDITIONS PRIOR TO COMMENCING WORK AND IF ANY DISCREPANCIES ARE FOUND,
<br />REPORT TO DESIGNER IMMEDIATELY.
<br />2. DO NOT SCALE DRAWINGS, DIMENSIONS SHALL TAKE PRECEDENCE OVER DRAWINGS.
<br />3.ALL WORK AND MATERIAL SHALL CONFORM TO THE REQUIREMENTS OF THE CURRENT ADDITION OF THE LOCAL CODES, AND ORDINANCES AND THE
<br />REGULATIONS COVERING THIS CONSTRUCTION
<br />4. CONTRACTOR SHALL VERIFY ALL THE ELECTRICAL, MECHANICAL, PLUMBING ROUGH-IN LOCATIONS FOR ANY SPECIAL EQUIPMENT WITH SUPPLIER OF
<br />SUCH EQUIPMENT.
<br />5. CONTRACTOR TO VERIFY ALL EXISTING FOOTINGS, FRAMING, ELECTRICAL, PLUMBING AND MECHANICAL CONDITIONS.
<br />6. CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING, AND FRAMING FOR INTERIOR FINISHES, LIGHT FIXTURES, ELECTRICAL UNITS, A/C
<br />EQUIPMENT, AND OTHER MISCELLANEOUS ITEMS.
<br />7. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM THE FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10
<br />FT (5%). WHERE LOT LINES, WALLS, SLOPES OR OTHER PHYSICAL BARRIER PROHIBIT 6" OF FALL WITHIN 10 FT, DRAINS OR SWALES SHALL BE CONSTRUCTED
<br />TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE [CRC R401.3].
<br />8. IMPERVIOUS SURFACES WITHIN 10 FT OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2% AWAY FROM THE BUILDING [CRC R401.3
<br />EXCEPTION].
<br />9.APPLICATIONS FOR WHICH NO PERMIT IS ISSUED WITHIN 180 DAYS FOLLOWING THE DATE OF APPLICATION SHALL AUTOMATICALLY EXPIRE.
<br />10. EVERY PERMIT ISSUED SHALL BECOME INVALID UNLESS WORK AUTHORIZED IS COMMENCED WITHIN 180 DAYS AFTER ITS ISSUANCE OR IF THE WORK
<br />AUTHORIZED IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS. A SUCCESSFUL INSPECTION MUST BE OBTAINED WITHIN 180 DAYS.
<br />11. AIRPORT NOISE IMPACT ZONE (PART 150): NO.
<br />12. BASIC WIND SPEED: VULT =110 NPH, EXPOSURE C.
<br />GREEN BUILDING NOTES
<br />1. ANNUAL SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE
<br />PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD.
<br />2. WASTE MANAGEMENT PLAN: THE CITY OF ANAHEIM ORDINANCE REQUIRES THAT CONSTRUCTION MATERIALS FROM NEW CONSTRUCTION, REMODELING,
<br />OR DEMOLITION SHALL BE IDENTIFIED FOR REUSE, RECYCLING, OR DISPOSAL. THE INTENT IS TO REUSE OR RECYCLE AT LEAST 65% OF CONSTRUCTION
<br />WASTE.
<br />3. AT ROUGH INSTALLATION OR DURING STORAGE ON THE SITE AND UNTIL FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT, ALL DUCT AND
<br />OTHER RELATED AIR DISTRIBUTION OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL OR OTHER ACCEPTABLE METHODS TO REDUCE DUST
<br />OR DEBRIS WHICH MAY COLLECT IN THE SYSTEM.
<br />4. ALL FINISH MATERIALS, SUCH AS ADHESIVES, SEALANTS, CAULKS, PAINTS, AEROSOL PAINTS, COATINGS, CARPET SYSTEMS, RESILIENT FLOORING
<br />SYSTEMS AND COMPOSITE WOOD PRODUCTS SHALL CONFORM TO THE VOC AND FORMALDEHYDE LIMITS SET FOR IN SECTION 4.502.2, 4.504.3, 4.504.4,
<br />4.504.4, 4.504.5 AND TABLES 4.504.1, 4.504.2, 4.503.3 AND 4.504.5
<br />5. EXHAUST FANS IN BATHROOMS (ROOMS WHICH CONTAIN A BATHTUB, SHOWER, OR TUB/ SHOWER COMBINATION) SHALL COMPLY WITH THE FOLLOWING.
<br /> A. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING.
<br /> B. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, THE FAN MUST BE CONTROLLED BY A HUMIDITY CONTROL.
<br />HUMIDITY CONTROLS
<br /> SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 80%. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO
<br />AN EXHAUST
<br /> FAN AND IS NOT REQUIRED TO BE INTEGRAL.
<br />ADDITIONAL NOTES:
<br />1 . ALL NEW DOORS AND WINDOWS MUST COMPLY WITH BUILDING SECURITY STANDARDS.
<br />2 . BUILDING ADDRESS SHALL BE PROVIDED ON THE BUILDING IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET.
<br />3. ALL WORK TO BE EXPOSED FOR INSPECTION.
<br />4. ALL PROPOSED COLORS AND MATERIALS SHALL MATCH EXISTING (I.E. ROOF, SIDING, STUCCO, WINDOW TRIM, ETC.)
<br />5. BUILDING SECURITY REGULATIONS: FOR NEW BUILDINGS AND ADDITIONS, ALTERATIONS, AND REPAIRS WITHIN ANY TWELVE-MONTH PERIOD
<br />EXCEED FIFTY (50 %) PERCENT OF THE VALUE OF ANY EXISTING BUILDING OR STRUCTURE, EACH BUILDING OR STRUCTURE SHALL BE MADE TO
<br />CONFORM TO THE REQUIREMENTS FOR NEW BUILDINGS OR STRUCTURES AND COMPLY WITH THE BUILDING SECURITY REGULATIONS. SANTA ANA
<br />MUNICIPAL CODE CHAPTER 8, DIVISION 3.
<br />PAGE TABLE
<br />LABEL TITLE
<br />A1 PROJECT INFORMATION
<br />A2 (E) SITE PLAN
<br />A3 (N) SITE PLAN
<br />A3.1 (N) 1ST. FLOOR PLAN PRIMARY HOUSE
<br />A4 (N) ADU FLOOR PLAN
<br />A5 ELEVATIONS
<br />A6 ELEVATIONS
<br />A7 ELEVATIONS
<br />A8 ARCHITECTURAL DETAILS
<br />S.0 GENERAL NOTES
<br />S1 FOUNDATION PLAN & ROOF FRAMING PLAN
<br />SD1 STRUCTURAL DETAILS
<br />SD2 STRUCTURAL DETAILS
<br />E1 ELECTRICAL PLAN & NOTES
<br />MC1 (E) ROOF PLAN & MECHANICAL PLAN
<br />PB1 PLUMBING PLAN & NOTES
<br />PB2 PLUMBING NOTES
<br />T24.1 TITLE 24
<br />T24.2 TITLE 24
<br />PROJECT DESCRIPTION:
<br />CONVERT EXISTING GARAGE INTO AN NEW 387
<br />SQ.FT. ADU, EXISTING STRUCTURE TO REMAIN,
<br />CEILING JOIST TO BE ADDED TO THE STRUCTURE
<br />ALONG WITH STUCCO FINISH ON THE EXTERIOR.
<br />APPLICABLE BUILDING CODES:
<br />2022 CALIFORNIA BUILDING CODE
<br />2022 CALIFORNIA MECHANICAL CODE
<br />2022 CALIFORNIA PLUMBING CODE
<br />2022 CALIFORNIA ELECTRICAL CODE
<br />2022 CALIFORNIA ENERGY CODE
<br />2022 CALIFORNIA RESIDENTIAL CODE
<br />2022 CITY OF SANTA ANA MUNICIPAL CODE
<br />2022 TITLE 24 ENERGY CODE
<br />2022 CGBC
<br />CODE ANALYSIS:
<br />APN: 39627312
<br />TYPE OF CONSTRUCTION: V-B
<br />ZONING: R-3
<br />NUMBER OF STORIES: ONE STORY
<br />FIRE SPRINKLERS: N/A
<br />FEMA DESIGNATED FLOOD ZONE:
<br />THE PROPERTY IS LOCATED IN “ZONE X”
<br />(MINIMUM FLOOD ZONE HAZARD).
<br />CONSULTANT INFORMATION:
<br />COMPA'S DESIGN SERVICES
<br />949 N. IROQUOIS AVE.
<br />ANAHEIM, CA 92801
<br />714-797-9312
<br />COMPASDESIGNSERVICES@GMAIL.COM
<br />AREA SUMMARY
<br />(E) MAIN HOUSE = 1,373 SQ. FT.
<br />NEW ADU = 387 SQ. FT.
<br />TOTAL USED AREA = 1,760 SQ. FT.
<br />
<br />
<br />TOTAL LOT AREA = 10,730 SQ. FT.
<br />
<br />LOT COVERAGE PERCENTAGE: 1,760/ 10,730 = 0.16 * 100= 16%
<br />
<br />ADU SQ.FT RATIO CALCULATION: 387 / 1,373 = 0.28 * 100= 28%
<br />ENERGY DESIGNER:
<br />CARSTAIRS ENERGY INC.
<br />805.904.9048
<br />BRITAINI@CARTAIRSENERGY.COM
<br />PARKING TABULATION:
<br />HOUSE DRIVEWAY 3
<br />HOUSE GARAGE 0
<br />ADU 0 (EXEMPT; BUS STOP LESS THAN 0.5 MILES)
<br />
<br /> TOTAL 3
<br />OWNER INFORMATION:
<br />MANUEL & MARIA CASAS
<br />MAIN HOUSE ADDRESS:
<br />2617 DEODAR ST., SANTA ANA, CA 92705
<br />ADU ADDRESS:
<br />2617 DEODAR ST. UNIT #2, SANTA ANA, CA 92705
<br />Revision Table
<br />Number
<br />Date
<br />Revised By
<br />Description
<br />1
<br />10/27/2023
<br />JO
<br />PLANNING
<br />2
<br />01/31/2024
<br />JO
<br />PLANNING
<br />3
<br />03/08/2024
<br />JO
<br />BP
<br />4
<br />04/02/2024
<br />JO
<br />PCC
<br />5
<br />11/25/2024
<br />JO
<br />PCC
<br />6
<br />04/15/2025
<br />JO
<br />PCC
<br />COMPA'S DESIGN SERVICES
<br />949 N. IROQUOIS AVE.
<br />ANAHEIM, CA 92801
<br />JUAN ORELLANA _____________
<br />VECINITY MAP PROJECT
<br />INFORMATION
<br />BUS STOP
<br />PROJECT NAME: MANUEL & MARIA CASAS
<br />MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
<br />SANTA ANA, CA 92705
<br />ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
<br />SANTA ANA, CA 92705
<br />Juan
<br />Orellana
<br />Bldg #101119933
<br />APPROVALS:
<br />PLNG - F. Arias
<br />BLDG - CSG
<br />POLICE - B. Martin
<br />PUBLIC WORKS - Y. Soto
|