HomeMy WebLinkAbout2617 N Deodar St & Unit# 2 - PlanA1
SHEET:
SCALE:
DATE:
04/15/2025
GENERAL NOTES
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, GRADES, AND SITE CONDITIONS PRIOR TO COMMENCING WORK AND IF ANY DISCREPANCIES ARE FOUND,
REPORT TO DESIGNER IMMEDIATELY.
2. DO NOT SCALE DRAWINGS, DIMENSIONS SHALL TAKE PRECEDENCE OVER DRAWINGS.
3.ALL WORK AND MATERIAL SHALL CONFORM TO THE REQUIREMENTS OF THE CURRENT ADDITION OF THE LOCAL CODES, AND ORDINANCES AND THE
REGULATIONS COVERING THIS CONSTRUCTION
4. CONTRACTOR SHALL VERIFY ALL THE ELECTRICAL, MECHANICAL, PLUMBING ROUGH-IN LOCATIONS FOR ANY SPECIAL EQUIPMENT WITH SUPPLIER OF
SUCH EQUIPMENT.
5. CONTRACTOR TO VERIFY ALL EXISTING FOOTINGS, FRAMING, ELECTRICAL, PLUMBING AND MECHANICAL CONDITIONS.
6. CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING, AND FRAMING FOR INTERIOR FINISHES, LIGHT FIXTURES, ELECTRICAL UNITS, A/C
EQUIPMENT, AND OTHER MISCELLANEOUS ITEMS.
7. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM THE FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10
FT (5%). WHERE LOT LINES, WALLS, SLOPES OR OTHER PHYSICAL BARRIER PROHIBIT 6" OF FALL WITHIN 10 FT, DRAINS OR SWALES SHALL BE CONSTRUCTED
TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE [CRC R401.3].
8. IMPERVIOUS SURFACES WITHIN 10 FT OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2% AWAY FROM THE BUILDING [CRC R401.3
EXCEPTION].
9.APPLICATIONS FOR WHICH NO PERMIT IS ISSUED WITHIN 180 DAYS FOLLOWING THE DATE OF APPLICATION SHALL AUTOMATICALLY EXPIRE.
10. EVERY PERMIT ISSUED SHALL BECOME INVALID UNLESS WORK AUTHORIZED IS COMMENCED WITHIN 180 DAYS AFTER ITS ISSUANCE OR IF THE WORK
AUTHORIZED IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS. A SUCCESSFUL INSPECTION MUST BE OBTAINED WITHIN 180 DAYS.
11. AIRPORT NOISE IMPACT ZONE (PART 150): NO.
12. BASIC WIND SPEED: VULT =110 NPH, EXPOSURE C.
GREEN BUILDING NOTES
1. ANNUAL SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE
PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD.
2. WASTE MANAGEMENT PLAN: THE CITY OF ANAHEIM ORDINANCE REQUIRES THAT CONSTRUCTION MATERIALS FROM NEW CONSTRUCTION, REMODELING,
OR DEMOLITION SHALL BE IDENTIFIED FOR REUSE, RECYCLING, OR DISPOSAL. THE INTENT IS TO REUSE OR RECYCLE AT LEAST 65% OF CONSTRUCTION
WASTE.
3. AT ROUGH INSTALLATION OR DURING STORAGE ON THE SITE AND UNTIL FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT, ALL DUCT AND
OTHER RELATED AIR DISTRIBUTION OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL OR OTHER ACCEPTABLE METHODS TO REDUCE DUST
OR DEBRIS WHICH MAY COLLECT IN THE SYSTEM.
4. ALL FINISH MATERIALS, SUCH AS ADHESIVES, SEALANTS, CAULKS, PAINTS, AEROSOL PAINTS, COATINGS, CARPET SYSTEMS, RESILIENT FLOORING
SYSTEMS AND COMPOSITE WOOD PRODUCTS SHALL CONFORM TO THE VOC AND FORMALDEHYDE LIMITS SET FOR IN SECTION 4.502.2, 4.504.3, 4.504.4,
4.504.4, 4.504.5 AND TABLES 4.504.1, 4.504.2, 4.503.3 AND 4.504.5
5. EXHAUST FANS IN BATHROOMS (ROOMS WHICH CONTAIN A BATHTUB, SHOWER, OR TUB/ SHOWER COMBINATION) SHALL COMPLY WITH THE FOLLOWING.
A. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING.
B. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, THE FAN MUST BE CONTROLLED BY A HUMIDITY CONTROL.
HUMIDITY CONTROLS
SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 80%. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO
AN EXHAUST
FAN AND IS NOT REQUIRED TO BE INTEGRAL.
ADDITIONAL NOTES:
1 . ALL NEW DOORS AND WINDOWS MUST COMPLY WITH BUILDING SECURITY STANDARDS.
2 . BUILDING ADDRESS SHALL BE PROVIDED ON THE BUILDING IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET.
3. ALL WORK TO BE EXPOSED FOR INSPECTION.
4. ALL PROPOSED COLORS AND MATERIALS SHALL MATCH EXISTING (I.E. ROOF, SIDING, STUCCO, WINDOW TRIM, ETC.)
5. BUILDING SECURITY REGULATIONS: FOR NEW BUILDINGS AND ADDITIONS, ALTERATIONS, AND REPAIRS WITHIN ANY TWELVE-MONTH PERIOD
EXCEED FIFTY (50 %) PERCENT OF THE VALUE OF ANY EXISTING BUILDING OR STRUCTURE, EACH BUILDING OR STRUCTURE SHALL BE MADE TO
CONFORM TO THE REQUIREMENTS FOR NEW BUILDINGS OR STRUCTURES AND COMPLY WITH THE BUILDING SECURITY REGULATIONS. SANTA ANA
MUNICIPAL CODE CHAPTER 8, DIVISION 3.
PAGE TABLE
LABEL TITLE
A1 PROJECT INFORMATION
A2 (E) SITE PLAN
A3 (N) SITE PLAN
A3.1 (N) 1ST. FLOOR PLAN PRIMARY HOUSE
A4 (N) ADU FLOOR PLAN
A5 ELEVATIONS
A6 ELEVATIONS
A7 ELEVATIONS
A8 ARCHITECTURAL DETAILS
S.0 GENERAL NOTES
S1 FOUNDATION PLAN & ROOF FRAMING PLAN
SD1 STRUCTURAL DETAILS
SD2 STRUCTURAL DETAILS
E1 ELECTRICAL PLAN & NOTES
MC1 (E) ROOF PLAN & MECHANICAL PLAN
PB1 PLUMBING PLAN & NOTES
PB2 PLUMBING NOTES
T24.1 TITLE 24
T24.2 TITLE 24
PROJECT DESCRIPTION:
CONVERT EXISTING GARAGE INTO AN NEW 387
SQ.FT. ADU, EXISTING STRUCTURE TO REMAIN,
CEILING JOIST TO BE ADDED TO THE STRUCTURE
ALONG WITH STUCCO FINISH ON THE EXTERIOR.
APPLICABLE BUILDING CODES:
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA RESIDENTIAL CODE
2022 CITY OF SANTA ANA MUNICIPAL CODE
2022 TITLE 24 ENERGY CODE
2022 CGBC
CODE ANALYSIS:
APN: 39627312
TYPE OF CONSTRUCTION: V-B
ZONING: R-3
NUMBER OF STORIES: ONE STORY
FIRE SPRINKLERS: N/A
FEMA DESIGNATED FLOOD ZONE:
THE PROPERTY IS LOCATED IN “ZONE X”
(MINIMUM FLOOD ZONE HAZARD).
CONSULTANT INFORMATION:
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
714-797-9312
COMPASDESIGNSERVICES@GMAIL.COM
AREA SUMMARY
(E) MAIN HOUSE = 1,373 SQ. FT.
NEW ADU = 387 SQ. FT.
TOTAL USED AREA = 1,760 SQ. FT.
TOTAL LOT AREA = 10,730 SQ. FT.
LOT COVERAGE PERCENTAGE: 1,760/ 10,730 = 0.16 * 100= 16%
ADU SQ.FT RATIO CALCULATION: 387 / 1,373 = 0.28 * 100= 28%
ENERGY DESIGNER:
CARSTAIRS ENERGY INC.
805.904.9048
BRITAINI@CARTAIRSENERGY.COM
PARKING TABULATION:
HOUSE DRIVEWAY 3
HOUSE GARAGE 0
ADU 0 (EXEMPT; BUS STOP LESS THAN 0.5 MILES)
TOTAL 3
OWNER INFORMATION:
MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS:
2617 DEODAR ST., SANTA ANA, CA 92705
ADU ADDRESS:
2617 DEODAR ST. UNIT #2, SANTA ANA, CA 92705
Revision Table
Number
Date
Revised By
Description
1
10/27/2023
JO
PLANNING
2
01/31/2024
JO
PLANNING
3
03/08/2024
JO
BP
4
04/02/2024
JO
PCC
5
11/25/2024
JO
PCC
6
04/15/2025
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
VECINITY MAP PROJECT
INFORMATION
BUS STOP
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
Juan
Orellana
Bldg #101119933
APPROVALS:
PLNG - F. Arias
BLDG - CSG
POLICE - B. Martin
PUBLIC WORKS - Y. Soto
SHEET:
SCALE:
DATE:
11/25/2024
Re
v
i
s
i
o
n
T
a
b
l
e
Nu
m
b
e
r
Da
t
e
Re
v
i
s
e
d
B
y
De
s
c
r
i
p
t
i
o
n
CO
M
P
A
'
S
D
E
S
I
G
N
S
E
R
V
I
C
E
S
94
9
N
.
I
R
O
Q
U
O
I
S
A
V
E
.
AN
A
H
E
I
M
,
C
A
9
2
8
0
1
JU
A
N
O
R
E
L
L
A
N
A
_
_
_
_
_
_
_
_
_
_
_
_
_
PR
O
J
E
C
T
N
A
M
E
:
MA
N
U
E
L
&
M
A
R
I
A
C
A
S
A
S
AD
D
R
E
S
S
:
26
1
7
D
E
O
D
A
R
S
T
.
U
N
I
T
#2
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
5
1
10
/
2
7
/
2
0
2
3
JO
PL
A
N
N
I
N
G
2
10
/
3
1
/
2
0
2
4
JO
PL
A
N
N
I
N
G
3
03
/
0
8
/
2
0
2
4
JO
BP
4
04
/
0
2
/
2
0
2
4
JO
PC
C
5
25
/
1
1
/
2
0
2
4
JO
PC
C
9NONE
SCALE:
11NONE
SCALE:
14NONE
SCALE:
10NONE
SCALE:6NONE
SCALE:
7NONE
SCALE:
2NONE
SCALE:
NOT USE
4NONE
SCALE:1NONE
SCALE:
3NONE
SCALE:
HOLD-DOWN SCHEDULE
12NONE
SCALE:
5NONE
SCALE:WINDOW STRAP AT SHEAR WALL
SHEARWALL SCHEDULE8NONE
SCALE:
13NONE
SCALE:
NOT USENOT USE
NOT USE NOT USE
NOT USE
NOT USENOT USENOT USENOT USE
NOT USE
A10
ST
R
U
C
T
U
R
A
L
DE
T
A
I
L
S
B24R
SB48
B24R
B24R
BCB24R
RB45
B2448R
B24R
SB48
B24R
B24R
BCB24R
RB45
B2448R
WH
W2436R W2436R W2436R W2436R W2436R W2436R
W2436R
3030LS
6030LS
8068
3068
7640TS
6030LS
3040LS
5030LS
3068
3030LS
6030LS
14080
3068
2668
2668
2668
2668
2668
2668
2168
31168
2668 2668
2668
2668
8068
6150
3068
1668
5068
5068
1868
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
E1
A6
E1
A6
ELEVATION 1
E2E2
ELEVATION 2
E3
A7
E3
A7
ELEVATION 3
E4
A5
E4
A5
ELEVATION 4
25'-6"
4'-11"
6'
5'-7"
1'-11"
7'-6"
1'-7"
3'
4"
7'-3"
8'
6'-1"
16'-6"
14'-4"
21'-4"
52'-2"
12'
10'-3"
15'-10"
61'-2"
26'-1"
50'-6"
21'
2'-1"
14'
2'-1"
18'-2"
52'-2"
7'-4"
3'-4"
6'
3'-7"7"
3'9"4"
3'9"1'-6"
5'1'-10"9"
3'
7"
6'-1"2'-4"
10'-7"
4'-4"4'-1"
8'-4"
4'-4"
1'-7"6'
1'-6"1'3'3'
21'-1"
9'-1"
7'
9'-11"
47'-1"
38'-10"
43'-10"
142'-9"
147'-2"
9'-1" X 16'-0"
11'-0" X 11'-8"
17'-2" X 20'-7"
3'-8" X 15'-5"
11'-11" X 12'-1"
9'-8" X 20'-6"
8'-9" X 10'-7"
13'-1" X 14'-0"
17'-2" X 4'-5"
12'-0" X 8'-0"
2'-3" X 2'-11"
2'-8" X 12'-1"
GARAGE
BEDROOM 2
BEDROOM 3
BEDROOM 4
MASTER BEDROOM LIVING
HALL
DINING
KITCHEN
PORCH
CLOSET
LAUNDRY
4X4 POST
4X4 POST
N
A2
SHEET:
SCALE:
DATE:
11/25/2024
Revision Table
Number
Date
Revised By
Description
1
10/27/2023
JO
PLANNING
2
01/31/2024
JO
PLANNING
3
03/08/2024
JO
BP
4
04/02/2024
JO
PCC
5
11/25/2024
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
(E) SITE PLAN
SCALE: 1/8" = 1'-0"
(E) SITE PLAN
PROPERTY LINE
PROPERTY LINE
PROPERTY LINEBACK YARD
FRONT YARD
DRIVEWAY
1/8" = 1'-0"
DEODAR ST.
COSTA MESA FWY
(E) GARAGE TO BE CONVERTED INTO A
NEW 387 SQ. FT. ADU
(E) GAS METER
(E) WATER METER
(E) 6' HIGH
WOODEN FENCE
(E) 6' HIGH CMU BLOCK
WALL FENCE
(E) 10' HIGH CMU
BLOCK WALL FENCE
(E) 6' HIGH CMU WALL
(E) 6' X 6'
PREFABRICATED
SHED
(E) WATER HEATER
TO BE REPLACE
(E) HOUSE
(E) 5' HIGH CMU WALL
TO BE REMOVED
(E) POWER METER
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
N
B24R
SB48
B24R
B24R
BCB24R
RB45
B2448R
B24R
B21R
SB48
B15R
B24R
SB48
B24R
B24R
BCB24R
RB45
B2448R
B24R
B21R
SB48
B15R
U301890
WH
W2436R W2436R W2436R W2436R W2436R W2436R
W2436R
W1636R
W2136R
W2436R W2724
3030LS
6030LS
8068
3068
7640TS
6030LS
3040LS
5030LS
3068
3030LS
6030LS
W04W04
W02W02
W03W03
W03W03
2668
2668
D02D02
2668
2668
2668
2668
2168
5068
5068
2668 2668
2668
2668
8068
W01W01
D01D01
D03D03
D04D04
1668
1868
31168
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / L
30X22
ATTIC
ACCESS
GFCIGFCI
GFCIGFCI
CO/SD
GFCIGFCI
GFCIGFCI
GFCIGFCI
GFCIGFCI
R
R
R
R
3
GFCIGFCI
GFCIGFCI
GFCI
GFCI
VS
R
R
3
EP
E5
A8
E5
A8
ELEVATION 5
E1
A6
E1
A6
ELEVATION 1
E2E2
ELEVATION 2
E3
A7
E3
A7
ELEVATION 3
E4
A5
E4
A5
ELEVATION 4
4'-11"
6'
5'-7"
1'-11"
7'-6"
1'-7"
3'
4"
7'-3"
8'
6'-1"
16'-6"
14'-4"
21'-4"
52'-2"
10'-8"
10'-3"
15'-10"
61'-2"
26'-1"
50'-6"
4'-2"
4'
4'
4'
2'
18'-2"
52'-2"
7'-4"
3'-4"
6'
3'-7"7"
3'9"4"
3'9"1'-6"
5'1'-10"9"
3'
7"
6'-1"
12'-11"
4'-4"4'-1"
8'-4"
4'-4"
11'-4"
3'8'-4"
6'
1'-6"1'3'3'
21'-1"
9'-1"
7'
9'-11"
47'-1"
38'-10"
4'
21'
1'-6"
30"
9'-1" X 16'-0"
9'-3" X 11'-7"
3'-8" X 15'-5"
11'-11" X 12'-1"
9'-8" X 20'-6"
8'-9" X 12'-4"
13'-1" X 14'-0"
6'-0" X 8'-0"
17'-2" X 4'-5"
1'-5" X 5'-5"
12'-0" X 8'-0"
2'-11" X 2'-3"
3'-0" X 6'-5"
BEDROOM 2
BEDROOM 3
BEDROOM 4
MASTER BEDROOM LIVING
HALL
DINING
KITCHEN
PORCH
BATH
LAUNDRY
LAUNDRY
CLOSET
VS
4X4 POST
4X4 POST
A3
SHEET:
SCALE:
DATE:
04/15/2025
Revision Table
Number
Date
Revised By
Description
1
10/27/2023
JO
PLANNING
2
01/31/2024
JO
PLANNING
3
03/08/2024
JO
BP
4
04/02/2024
JO
PCC
5
11/25/2024
JO
PCC
6
04/15/2025
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
(N) SITE PLAN
(N) SITE PLAN
SCALE: 1/8" = 1'-0"
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
BACK YARD
FRONT
YARD
DRIVEWAY
DEODAR ST.
COSTA MESA FWY
1/8" = 1'-0"
(E) GARAGE TO BE
CONVERTED INTO A
(N) 387 SQ. FT. ADU
(E) GAS METER
(E) WATER METER
(E) 6' HIGH CMU BLOCK
WALL FENCE
(E) 6' HIGH CMU BLOCK
WALL FENCE (E) 10' HIGH CMU
BLOCK WALL FENCE
(E) 6' HIGH
WOODEN FENCE
(E) 6'X6'
PREFABRICATED
SHED
(N) TANKLESS WATER
HEATER
(E) HOUSE
(N) A/C DUCTLESS FAN
(N) ADU
CONDENSING UNIT
(E) POWER METER
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
Juan
Orellana
(E) WATER
HEATER
B24R
SB48
B24R
B24R
BCB24R
RB45
B2448R
B24R
B21R
SB48
B15R
B24R
SB48
B24R
B24R
BCB24R
RB45
B2448R
B24R
B21R
SB48
B15R
U301890
WH
W2436R
W2436R
W2436R
W2436R
W2436R
W2436R
W2436R
W1636R
W2136R
W2436R
W2724
E5
A8
E5
A8
ELEVATION 5
E1
A6
E1
A6
ELEVATION 1
E2E2
ELEVATION 2
E3
A7
E3
A7
ELEVATION 3
BEDROOM 2
BEDROOM 3
BEDROOM 4
MASTER BEDROOM
LIVING
HALL
DINING
KITCHEN
PORCH
BATH
LAUNDRY
LAUNDRY
CLOSET
N
B24R
SB48
B24R
B24R
BCB24R
RB45
B2448R
B24R
SB48
B24R
B24R
BCB24R
RB45
B2448R
WH
W2436R
W2436R
W2436R
W2436R
W2436R
W2436R
W2436R
E1
A6
E1
A6
ELEVATION 1
E2E2
ELEVATION 2
E3
A7
E3
A7
ELEVATION 3
GARAGE
BEDROOM 2
BEDROOM 3
BEDROOM 4
MASTER BEDROOM
LIVING
HALL
DINING
KITCHEN
PORCH
CLOSET
LAUNDRY
N
A3.1
SHEET:
SCALE:
DATE:
04/15/2025
Revision Table
Number
Date
Revised By
Description
1
01/31/2024
JO
PLANNING
2
03/08/2024
JO
BP
3
04/02/2024
JO
PCC
4
11/25/2024
JO
PCC
5
04/15/2025
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
(N) 1ST FLOOR PLAN -
PRIMARY HOUSE
SCALE: 1/4" = 1'-0"
(E) 1ST FLOOR PLAN
PRIMARY HOUSE
(N) 1ST. FLOOR PLAN - PRIMARY HOUSE 12
(E) WATER HEATER TO
REMAIN
(E) HOUSE
(N) 387 SQ. FT. ADU
(E) FURNACE
(N) A/C DUCTLESS FAN (E) 1ST FLOOR PLAN -
PRIMARY HOUSE
SCALE: 1/4" = 1'-0"
IMAGES OF EXTERIOR FACADES
(E) 1ST. FLOOR PLAN - PRIMARY HOUSE
(E) HOUSE
(E) GARAGE TO BE
CONVERTED INTO A
(N) 387 SQ. FT. ADU
(E) FURNACE
(E) WATER HEATER
(N) ADU
CONDENSING UNIT
1/4" = 1'-0"
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
3
EXTERIOR WALL
DEMOLITION AREAS FOR
NEW WINDOWS
EXTERIOR WALL
DEMOLITION AREAS FOR
NEW WINDOWS
(E) DOOR TO BE REPLACED
WITH NEW DOOR FOR ADU
(E) DOOR TO BE
REMOVED & WALL
TO BE CLOSED OFF
Juan
Orellana
(E) GAS METER
(N) ADU TANKLESS
WATER HEATER
B24R
B21R
SB48
B15R
B24R
B21R
SB48
B15R
W1636R
W2136R
W2436R
W2724
3040LS
W04W04
W02W02
W03W03
W03W03
D02D02
W01W01
D01D01
D03D03
D04D04
31168
30X22
ATTIC
ACCESS
GFCIGFCI
GFCIGFCI
CO/SD
GFCIGFCI
GFCIGFCI
GFCIGFCI
GFCIGFCI
R
R
R
R
3
GFCIGFCI
GFCIGFCI
GFCI
GFCI
VS
R
R
3
EP
E5
A8
E5
A8
ELEVATION 5
E1
A6
E1
A6
ELEVATION 1
4'-2"
4'
4'
4'
2'
18'-2"
52'-2"
7'-4"
1'-10"9"
3'
7"
4'-4"
11'-4"
3'8'-4"
21'-1"
9'-1"
47'-1"
21'
1'-6"
30"
9'-3" X 11'-7"
8'-9" X 12'-4"
6'-0" X 8'-0"
1'-5" X 5'-5"
3'-0" X 6'-5"
BEDROOM 2
BEDROOM 3
BATH
LAUNDRY
CLOSET
VS
4X4 POST
N
DOOR SCHEDULE
NUMBER LABEL QTY FLOOR SIZE R/O DESCRIPTION U-FACTOR
D01 3068 1 1 3068 R EX 38"X83"EXT. HINGED-DOOR E21 0.3
D02 2668 1 1 2668 R IN 32"X82 1/2"HINGED-DOOR P04 0.3
D03 4068 1 1 4068 L/R 50"X82 1/2"4 DR. BIFOLD-LOUVERED 0.3
D04 41068 1 1 41068 L/R 60"X82 1/2"4 DR. BIFOLD-LOUVERED 0.3
WINDOW SCHEDULE
NUMBER LABEL QTY FLOOR SIZE R/O EGRESS DESCRIPTION U-FACTOR SHGC TEMPERED
W01 2030LS 1 1 2030LS 25"X37"LEFT SLIDING 0.3 0.23 YES
W02 2030RS 1 1 2030RS 25"X37"RIGHT SLIDING 0.3 0.23
W03 4040LS 2 1 4040LS 49"X49"LEFT SLIDING 0.3 0.23
W04 3030LS 1 1 3030LS 37"X37"LEFT SLIDING 0.3 0.23
(E) EXTERIOR WALL
(N) EXTERIOR WALL
(E) INTERIOR WALL
(N) INTERIOR WALL A4
SHEET:
SCALE:
DATE:
11/25/2024
Revision Table
Number
Date
Revised By
Description
1
10/27/2023
JO
PLANNING
2
01/31/2024
JO
PLANNING
3
03/08/2024
JO
BP
4
04/02/2024
JO
PCC
5
11/25/2024
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
(N) ADU - FLOOR PLAN
SCALE: 1/2" = 1'-0"
(N) ADU FLOOR
PLAN
1.) EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE
OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING
HAVING A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET
EXCEPT FOR GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM
NET CLEAR OPENING OF 5 SQUARE FEET. THE MIN. NET CLEAR
OPENING HEIGHT SHALL BE 24 IN., WIDTH SHALL BE 20 IN. MIN.,
AND BOTTOM OF THE CLEAR OPENING SHALL BE NO GREATER
THAN 44 INCHES MEASURED FROM THE FLOOR. PROVIDE
EMERGENCY ESCAPE AND RESCUE OPENING FOR EVERY
SLEEPING ROOM. CRC R310. SHOW THAT BEDROOM WINDOW
COMPLIES
2). “CARBON MONOXIDE ALARM SHALL BE INTERCONNECTED
HARD-WIRED WITH BATTERY BACKUP.” E. BATTERY CARBON
MONOXIDE ALARM IS PERMITTED IN EXISTING DWELLING UNITS
WHERE NO CONSTRUCTION IS TAKING PLACE.
3). THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS
MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION. MAX. U-
FACTOR: 0.30 MAX. SHGC: 0.23 ENERGY CODE REQUIREMENTS:
(TABLE 150.1-A)
4). ADU ADDRESSING - BUILDING SHALL HAVE APPROVED
ADDRESS NUMBERS (CRC R319.1) IN A POSITION THAT IS
PLAINLY VISIBLE FROM THE STREET FRONTING THE PROPERTY.
NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND.
ADDRESS NUMBERS SHALL BE A MINIMUM 4 INCHES HIGH AND
1/2 INCH STROKE WIDTH. SHOW ON ELEVATION. A. IF
ILLUMINATED; COMPLY WITH CALIFORNIA ENERGY CODE
SECTION 140.8; OR B. SIGN SHALL CONSUME NO MORE THAN 5
WATTS OF POWER AS DETERMINED ACCORDING TO SECTION
130.0(C) (15)
5). VAPOR RETARDER IS REQUIRED OVER (E) GARAGE SLAB AS
REQUIRED IN SECTION R506.2.3. PROVIDE REDGARD
WATERPROOFING AND CRACK PREVENTION MEMBRANE.
APPLICATION PER ICC - ESR#1413.
6). THE EXTERIOR LANDING OR FINISHED FLOOR SHALL NOT BE
MORE THAN 7 3/4" BELOW THE TOP OF THE THRESHOLD
PROVIDED THE DOOR DOES NOT SWING OVER THE LOVER
LANDING OR FLOOR.
GENERAL NOTES
HERS ITEMS LIST
(N) WINDOWS AND DOORS SCHEDULE
1/2" = 1'-0"
(N) A/C DUCTLESS FAN
(N) PREFABRICATED
SHOWER WITH GRAB BARS
SEE AGING-IN PLACE
REQUIREMENTS NOTES.EXHAUST FAN (50 CFM) WITH HUMIDITY CONTROL WITH LED
LIGHT (HIGH EFFICACY)
FAN WITH LED LIGHT (HIGH EFFICACY)
EXTERIOR LIGHT W/PHOTO SENSOR CONTROL AND MOTION
DETECTOR
6" RECESSED LED LIGHT (HIGH EFFICACY)
VANITY LED LIGHT (HIGH EFFICACY)
CEILING MOUNTED LED LIGHT (HIGH EFFICACY)
1. DOORBELL BUTTONS - DOORBELL BUTTONS OR CONTROLS, WHEN
INSTALLED, SHALL NOT EXCEED 48 INCHES ABOVE EXTERIOR FLOOR OR
LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON
ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER
FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES
MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD
DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A
HEIGHT NOT EXCEEDING 48 INCHES ABOVE EXTERIOR FLOOR OR
LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR
CONTROL. (CRC R327.1.4)
2. AGING-IN-PLACE ELEMENTS - AT LEAST ONE BATHROOM ON THE
ENTRY LEVEL (SEE DEFINITION) SHALL BE PROVIDED WITH
REINFORCEMENT INSTALLED IN ACCORDANCE WITH CRC R327.1.
WHERE THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE
BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL
COMPLY WITH CRC R327.1.
3. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER
CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY.
REINFORCEMENT SHALL NOT BE LESS THAN 2X8 NOMINAL LUMBER (1-1/2
INCH BY 7-1/4 INCH ACTUAL DIMENSION) OR OTHER CONSTRUCTION
MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY.
REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES AND 39-1/4
INCHES ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING.
4. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE
WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL.
5. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL
FRAMING IS PROVIDED.
6. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT
SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK
WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER
GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO
MORE THAN 6 INCHES ABOVE THE BATHTUB RIM.
EXCEPTIONS:
I. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE
WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM
SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED,
FOLDAWAY, OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS
APPROVED BY THE ENFORCING AGENCY.
II. REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR
PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS
WITH INTEGRAL FACTORY- INSTALLED GRAB BARS OR WHEN FACTORY-
INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED.
III. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF
REINFORCEMENT AND/OR GRAB BARS SHALL BE PERMITTED, PROVIDED
REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS
OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY.
IV. BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS
DO NOT PERMIT THE INSTALLATION OF REINFORCEMENT SHALL BE
PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-
MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE
METHOD IS APPROVED BY THE ENFORCING AGENCY.
V. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR
BATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETE SLAB
FLOORS.
DOCUMENTATION FOR GRAB BAR REINFORCEMENT - INFORMATION AND/
OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB BAR
REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND
MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN
BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.4. (CRC R327.1.1.1)
AGING-IN PLACE REQUIREMENTS
1HR FIRE
RATED WALL
1HR FIRE
RATED WALL
1
A8
1
A8
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
WALL LEGEND
(N) 4'W X 3'D CONCRETE LANDING:
WITH ELEVATION OF 1-1/2" FROM
THE TOP OF THE THRESHOLD TO
TOP OF CONCRETE LANDING. SEE
NOTE 6 FROM GENERAL NOTES.
SHOWER WALLS SHALL BE
FINISHED WITH A NON-
ABSORBENT SURFACE TO A
HEIGHT OF 72 ABOVE THE
FLOOR. UTILIZE FIBERMAT
REINFORCED CEMENT
BACKER BOARD AS A BASE
FOR TILE. ENCLOSURE
DOORS AND / OR PANELS
SHALL BE TEMPERED
GLASS.
1. ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS
(INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR
CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE
LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE
OUTLET BOX AND NOT LESS THAN 15 INCHES MEASURED FROM THE
BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR.
EXCEPTIONS:
I. DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS;
CONTROLS MOUNTED ON CEILING FANS AND CEILING LIGHTS; AND
CONTROLS LOCATED ON APPLIANCES.
II. RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL
CODE ON A WALL SPACE WHERE THE DISTANCE BETWEEN THE FINISHED
FLOOR AND A BUILT-IN FEATURE ABOVE THE FINISH FLOOR, SUCH AS A
WINDOW, IS LESS THAN 15 INCHES.
2. ADDS AUTO-OFF CONTROLS FOR LIGHTING CONTROLS IN DRAWERS
AND CABINETS.
3. UNDERSHELF, DISPLAY CABINETS, SWITCHED OUTLETS CONTROLLED
SEPARATE FROM THE CEILING LIGHTING.
4. LIGHTING IN HABITABLE SPACES SHALL HAVE ACCESSIBLE WALL-
MOUNTED DIMMING CONTROLS.
ELECTRICAL OUTLET AND SWITCH
NOTES:VAPOR RETARDER IS
REQUIRED OVER (E) GARAGE
SLAB AS REQUIRED IN
SECTION R506.2.3. PROVIDE
REDGARD WATERPROOFING
AND CRACK PREVENTION
MEMBRANE, C-CURE PRO-RED
WATERPROOFING AND ANTI-
FRACTURE MEMBRANE, AND
JAMBO WATERPROOFING
MEMBRANE APPLICATION PER
ICC-ESR#1413
16'-2"
13'
15'-3"
3040LS
5030LS
W03W03
6030LS
W03W03
3030LS
16'-2"
13'
15'-3"
3040LS
5030LS
W03W03
6030LS
W03W03
3030LS
(E) ROOF PITCH
4
12
(E) ROOF PITCH
4
12
(E) 6' HIGH WOODEN FENCE
(E) 6' HIGH WOODEN FENCE
(E) ASPHALT SHINGLE
(E) ASPHALT SHINGLE
A5
SHEET:
SCALE:
DATE:
11/25/2024
Revision Table
Number
Date
Revised By
Description
1
10/27/2023
JO
PLANNING
2
01/31/2024
JO
PLANNING
3
03/08/2024
JO
BP
4
04/02/2024
JO
PCC
5
11/25/2024
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
(E) SOUTHWEST ELEVATION
(N) SOUTHWEST ELEVATION
ELEVATIONS
(N) WINDOW(N) WINDOW
(E) WINDOW (E) WINDOW (E) WINDOW (E) WINDOW(E) DOOR
(E) GARAGE DOOR(E) DOOR (E) WINDOW(E) WINDOW(E) WINDOW (E) WINDOW
1/4" = 1'-0"
(E) SAND FINISHED
STUCCO W/PAINT (TYP.)
(N) SAND FINISHED
STUCCO
W/PAINT (TYP.)
(E) SAND FINISHED STUCCO
W/PAINT (TYP.)
(E) GARAGE TO BE CONVERTED INTO A
NEW 387 SQ. FT. ADU
(E) HOUSE
(E) HOUSE
(N) 387 SQ. FT. ADU
(N) WINDOW TRIM TO
MATCH EXISTING
(E) 6' HIGH CMU BLOCK
WALL FENCE
(E) 6' HIGH CMU BLOCK
WALL FENCE
(E) 10' HIGH CMU
BLOCK WALL
(E) 5' HIGH CMU WALL
TO BE REMOVED
(E) 10' HIGH CMU
BLOCK WALL FENCE
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
16'-2"
13'
W01W01
6030LS 3030LS
16'-2"
13'
W01W01
6030LS 3030LS
(E) ROOF PITCH
4
12
(E) ROOF PITCH
4
12
(E) 6' HIGH WOODEN FENCE
(E) 6' HIGH WOODEN FENCE
(E) ASPHALT SHINGLE
(E) ASPHALT SHINGLE
A6
SHEET:
SCALE:
DATE:
02/04/2024
Revision Table
Number
Date
Revised By
Description
1
10/27/2023
JO
PLANNING
2
01/31/2024
JO
PLANNING
3
03/08/2024
JO
BP
4
04/02/2024
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
(E) SOUTHEAST ELEVATION
(N) SOUTHEAST ELEVATION
ELEVATIONS(E) WINDOW (E) WINDOW
(E) WINDOW(E) WINDOW
(N) WINDOW(E) DOOR
1/4" = 1'-0"
(E) SAND FINISHED
STUCCO
W/PAINT (TYP.)
(E) SAND FINISHED
STUCCO
W/PAINT (TYP.)
(N) SAND FINISHED
STUCCO
W/PAINT (TYP.)
(E) SAND FINISHED
STUCCO
W/PAINT (TYP.)
(E) GARAGE TO BE CONVERTED INTO A
NEW 387 SQ. FT. ADU
(N) 387 SQ. FT. ADU
(E) HOUSE
(E) HOUSE
(E) DOOR
(N) WINDOW TRIM TO
MATCH EXISTING
(N) CONDENSING UNIT
(E) POWER METER
(E) POWER METER
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
13'
15'-3"
16'-2"
W04W04W02W02 13'
15'-3"
16'-2"
W04W04W02W02
(E) ROOF PITCH
4
12
(E) ROOF PITCH
4
12
(E) ASPHALT SHINGLE
(E) ASPHALT SHINGLE
A7
SHEET:
SCALE:
DATE:
04/15/2025
Revision Table
Number
Date
Revised By
Description
1
10/27/2023
JO
PLANNING
2
01/31/2024
JO
PLANNING
3
03/08/2024
JO
BP
4
04/02/2024
JO
PCC
5
11/25/2024
JO
PCC
6
04/15/2025
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
(E) NORTHWEST ELEVATION
(N) NORTHWEST ELEVATION
ELEVATIONS
(N) WINDOW
1/4" = 1'-0"
(E) SAND FINISHED
STUCCO
W/PAINT (TYP.)
(E) SAND FINISHED
STUCCO
W/PAINT (TYP.)
(N) SAND FINISHED
STUCCO
W/PAINT (TYP.)
(E) GARAGE TO BE CONVERTED INTO A
NEW 387 SQ. FT. ADU
(N) 387 SQ. FT. ADU
(E) HOUSE
(E) HOUSE
(E) POWER POLE
(E) POWER POLE
(E) POWER METER
(E) POWER METER
(E) GAS METER
(E) GAS METER
(N) WINDOW
(N) WINDOW TRIM TO
MATCH EXISTING
(E) 6' HIGH CMU BLOCK
WALL FENCE
(E) 6' HIGH CMU BLOCK
WALL FENCE (E) PORCH
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
Juan
Orellana
(N) TANKLESS WATER
HEATER
TM
PENETRATIO
N
3M FIRE BARRIER SEALANT
CP 25 WB+
WALL ASSEMBLY
W02W02
3040LS
8'-1"W02W02
3040LS
A8
SHEET:
SCALE:
DATE:
04/15/2025
Revision Table
Number
Date
Revised By
Description
1
10/27/2023
JO
PLANNING
2
01/31/2024
JO
PLANNING
3
03/08/2024
JO
BP
4
04/02/2024
JO
PCC
5
11/25/2024
JO
PCC
6
04/15/2025
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
13
2
1.) 2 LAYERS OF GRADE D PAPER UNDER STUCCO WHEN
OVER WOOD SHEATHING
2.) ONE LAYER OF NO. 15 ASPHALT FELT, COMPLYING WITH
ASTM D 226 FOR TYPE 1 FELT OR OTHER APPROVED
WATER-RESISTIVE BARRIER, IS REQUIRED FOR THE
EXTERIOR. SUCH MATERIAL SHALL BE APPLIED
HORIZONTALLY, WITH THE UPPER LAYER LAPPED OVER
THE LOWER LAYER NOT LESS THAN 2" AND WHERE JOINTS
OCCUR, THE MATERIAL SHALL BE LAPPED NOT LESS THAN
6 INCHES. WHERE APPLIED OVER WOOD BASED SHEATING,
A PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS
OF GRADE D PAPER IS REQUIRED.
3.) ROOF COVERING FOR NEW AND RECONSTRUCTION SHALL
BE A CLASS A OR CLASS B ROOF ASSEMBLY
4.) INSTALLATION OF ROOF SHALL BE IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATION
5.) ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES SHALL
HAVE CROSS VENTILATION FOR EACH SEPARATE ATTIC
SPACE. A NET FREE VENTILATION AREA OF NOT LESS THAN
1/150 OF THE SPACE VENTILATED. (SEE SHEET A8 FOR
CALCULATIONS)
6.) A MINIMUM OF 1 INCH IS REQURED BETWEEN THE
PLYWOOD AND THE INSULATION AND THE EAVE VENTS
7.) ASPHALT SHINGLES SHALL BE USED ONLY ON ROOF
SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL
(2:12) OR GREATER. R905.2.2
TYP. WATER RESISTIVE BARRIER DETAIL5
SECTION
STC 50 SOUND RATED & 1 HR. FIRE RATING PARTITION WALL ASSEMBLIES
ARCHITECTURE
DETAILS
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
PIPE PENETRATION AT WALL FIRE
(N) R-15 INSULATION
(N) R-15 INSULATION
(N) 1/2 DRYWALL
(N) 1/2 DRYWALL
(N) 1/2 DRYWALL
(N) CEILING
(N) R-30 TYP. @ CEILING
Juan
Orellana
6"
R-13 INSULATION
PTDF SILL WITH 5/8"⌀
ANCHOR BOLTS 6' O.C.
AND 12" FROM ENDS.,
U.N.O.
(E) LEVELING SAND
1/2" DRYWALL
2x4 STUDS
@ 16" O.C.
14# FELT MOISTURE
BARRIER
2 - #4 REBAR TOP
AND BOTTOM
STUCCO WEEP
SCREED.
STUCCO W/ WIRE
MESH
3/8" CDX PLYWOOD
W/ 8d @ 6.6.12
(E) 4" CONCRETE SLAB
WITH #4 BARS AT
THE BOTTOM.
V.I.F.
IN EPOXY
MIN.
6" DEEP. SET REBAR
DRILL A 3/4"⌀ HOLE
@ 18" O.C.
INTO (N) FOOTING
#4 x 24" DOWEL
REDGARD WATERPROOF
COATING, PER ESR 1413.
(E) F.G.
(N) LEVELING CONC
FILL OVER (E) SLAB
4" WX 6" H CONC CURB
W/(1) - #4 CONTI.
12"
4"
24
"
4"
6"
8"
TYP. STUD WALL FRAMING DETAIL
TYP. STUD WALL INTERSECTION TYP. NON-BEARING WALL SLAB6
TYP. STUD WALL FRAMING DETAIL
CEILING JOIST DETAIL 3 2
4
5
10987LUMBER MATERIAL SPECS TYP. NON-BEARING WALL TO CEILING
A9
ST
R
U
C
T
U
R
A
L
DE
T
A
I
L
S
SHEET:
SCALE:
DATE:
11/25/2024
Re
v
i
s
i
o
n
T
a
b
l
e
Nu
m
b
e
r
Da
t
e
Re
v
i
s
e
d
B
y
De
s
c
r
i
p
t
i
o
n
CO
M
P
A
'
S
D
E
S
I
G
N
S
E
R
V
I
C
E
S
94
9
N
.
I
R
O
Q
U
O
I
S
A
V
E
.
AN
A
H
E
I
M
,
C
A
9
2
8
0
1
JU
A
N
O
R
E
L
L
A
N
A
_
_
_
_
_
_
_
_
_
_
_
_
_
PR
O
J
E
C
T
N
A
M
E
:
MA
N
U
E
L
&
M
A
R
I
A
C
A
S
A
S
AD
D
R
E
S
S
:
26
1
7
D
E
O
D
A
R
S
T
.
U
N
I
T
#2
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
5
1
10
/
2
7
/
2
0
2
3
JO
PL
A
N
N
I
N
G
2
10
/
3
1
/
2
0
2
4
JO
PL
A
N
N
I
N
G
3
03
/
0
8
/
2
0
2
4
JO
BP
4
04
/
0
2
/
2
0
2
4
JO
PC
C
5
25
/
1
1
/
2
0
2
4
JO
PC
C
Ju
a
n
O
r
e
l
l
a
n
a
CONCRETE MATERIAL SPECSWEEP SCREED DETAIL
4 :
1
2
4 :
1
2
1'
CJ
-
1
RR
-
1
RR
-
1
(E) 2
X
R
I
D
G
E
B
D
T
O
R
E
M
A
I
N
4X4
H
D
R
4X4
H
D
R
4X4
H
D
R
4X4
H
D
R
4X
4
H
D
R
4X
4
H
D
R
CJ
-
2
1'
1'
1'
1'
(E) 12" WX 18"D
(V.I.F)
(E) 12" WX 18"D
(V.I.F)
(E) 12" WX 18"D
(V.I.F)
(N) 12" WX 24"D (V.I.F)
7
A9
3
A9
5
A9
5
A9
5
A9
VAPOR RETARDER IS REQUIRED OVER (E) GARAGE SLAB AS
REQUIRED IN SECTION R506.2.3. PROVIDE REDGARD
WATERPROOFING AND CRACK PREVENTION MEMBRANE, C-CURE
PRO-RED WATERPROOFING AND ANTI-FRACTURE MEMBRANE, AND
JAMBO WATERPROOFING MEMBRANE APPLICATION PER
ICC-ESR#1413
FOUNDATION PLAN
ROOF PLAN
SLAB REPAIR
MINIMUM FOUNDATION CONSTRUCTION
REQUIREMENTS UNDER EXEMPTIONS #5 ABOVE:
1.DEPTH OF FOUNDATIONS BELOW THE
NATURAL GRADE SHALL NOT BE LESS THAN
18 INCHES.
2.CONTINUOUS FOUNDATION SHALL BE
REINFORCED WITH AT LEAST FOUR
CONTINUOUS #4 REINFORCING BARS, TWO
#4 BARS AT THE TOP AND TWO #4 BARS AT
THE BOTTOM.
3.SLAB CONSTRUCTION SHALL BE MINIMUM 4"
THICK, REINFORCED WITH #4 BARS AT 18"
ON CENTER EACH WAY
4.DOWELING OF THE NEW FOUNDATIONS AND
SLABS INTO THE EXISTING FOUNDATIONS
AND SLABS SHALL BE REQUIRED. DOWELS
SHALL BE A MINIMUM OF 6" INTO THE
EXISTING CONCRETE AND SHALL EXTEND A
MINIMUM OF 24" INTO THE NEW CONCRETE.
DOWELS SHALL BE MINIMUM #3 BARS AT 18"
ON CENTER OR #4 BARS AT 24" ON CENTER.
ALTERNATE FOUNDATION DESIGN WITHOUT A
SOILS REPORT: THE ICC ORANGE CHAPTER
"FOUNDATION REQUIREMENTS FOR RESIDENTIAL
PROJECTS AND ACCESORY STRUCTURES" MAY
BE USED AS ALTERNATE FOUNDATION DESIGN
WITHOUT SOILS REPORT.
(N) 2X8 DF 2
CJ 24" O.C.
3/8" CDX PLYWOOD
W/ 8d @ 6.6.12
#6 AND LARGER
#5 AND SMALLER
A. POURED AGAINST EARTH
B. POURED AGAINST FORM BELOW GRADE
2''
1 1/2''
3''
2''
REINFORCING STEEL
GLULAMS/MFR. WD. PROD.
D. SLABS ON GRADE (FROM TOP OF SLAB)
E. COLUMNS AND BEAMS TO MAIN BARS
F. WALLS - EXPOSED TO WEATHER NOT
EXPOSED TO WEATHER, #11 AND SMALLER
CONCRETE
STRUCTURAL STEEL
GENERAL NOTES
C. FORMED SLABS
LUMBER/CARPENTRY
1 1/2''
#14 AND #18 1 1/2"
1''
1''FOUNDATION/SITEWORK
4X16 #1: Fb= 1000 PSI
SINGLE/REPETITIVE
6
2X6 #2: Fb= 1170/1345 PSI
2X8 #2: Fb= 1080/1242 PSI
2X10 #2: Fb= 990/1138 PSI
2X12 #2: Fb= 900/1150 PSI
2X14 #2: Fb= 810/ 931 PSI
4X6 #2: Fb= 1170 PSI
4X8 #2: Fb= 1170 PSI
4X10 #2: Fb= 1080 PSI
4X14 #1: Fb= 1000 PSI
6X12 #1: Fb= 1350 PSI
4X12 #1: Fb= 1100 PSI ; Fv=180 psi E= 1.7x10
2X4 #2: Fb= 1350/1552 PSI ; Fv=180 psi E=1.6x10
4X4 #2: Fb= 1350 PSI
2018 NDS STRESS VALUES FOR DOUGLAS FIR-LARCH:
CONC.
2''
2''
3/4"
MASONRY
2''
1 1/2''
1 1/2''
1 1/2"
2''
1''
1''
3/4"
1 1/2"
6X10 #1: Fb= 1350 PSI ; Fv=170 psi, E=1.6x10
LUMBER/CARPENTRY (cont.)
DESIGN LOADS:
SHEET INDEX:
S.0 STRUCTURAL GENERAL NOTES
S.1 FOUNDATION PLAN
ROOF FRAMING PLAN
SD1 FOUNDATION DETAILS
SD2 STRUCTURAL DETAILS
NAILING SCHEDULE
SEISMIC DESIGN DATA
IMPORTANCE FACTOR 1.0
SITE CLASS D
SS 1.337
S1 0.476
SDS 1.069
SD1 NULL
SDC D
LATERAL FORCE RESISTING SYSTEM 15
BASE SHEAR
CS 0.164
R 6.5
W 2.50
PROCEDURE USED ELF
REDUNDANCY FACTOR 1.3
WIND DESIGN
PROCEDURE USED MWFRS
BASIC WIND SPEED 95 MPH
RISK CATEGORY II
WIND EXPOSURE C
SOIL
SOIL REPORT PREPARED BY
PROJECT NUMBER
DATE
SOIL BEARING PRESSURE 1500 PSF
VERTICAL
11 PSF
ROOF RAFTER LL =
ROOF RAFTER DL =
20 PSF
15 PSF
INT. WALL DL = 10 PSF
EXT. WALL DL =
( CBC 2022 )
CEILING JOIST LL =
CEILING JOIST DL = 4 PSF
10 PSF
TYPICAL FLOOR/ROOF DECK/DECK SHEATHING
TYPICAL SLOPED/FLAT NON-ASSEMBLY ROOF SHEATHING
HORIZONTAL DIAPHRAGM:
6
6
12.ALL NAILING TO BE PER TABLE NUMBER 2304.10.2 OF THE LATEST
CALIFORNIA BUILDING CODE (CBC), UNLESS NOTED OTHERWISE.
13.PLYWOOD FLOOR AND ROOF SHEATHING SHALL BE LAID CONTINUOUS
OVER TWO OR MORE SUPPORTS WITH FACE GRAIN PERPENDICULAR TO
SUPPORTS (UNLESS SHOWN OTHERWISE). STAGGER ALL PLYWOOD
PANELS A MINIMUM OF 4'-0".
14.FLOOR SHEATHING TO BE NAILED AND GLUED TO THE JOISTS. USE
ADHESIVES PER A.P.A. AFG-01 OR ASTM D3498.
15.FRAMING CONTRACTOR SHALL PROVIDE BACKING AS REQUIRED FOR
ALL LIGHT FIXTURES, CABINETS, WARDROBES, TOWEL BARS, AND
HANDRAILS AS REQUIRED AND REQUESTED BY GENERAL CONTRACTOR.
16.EXTERIOR WOOD POSTS AND COLUMNS SUPPORTED BY A CONCRETE
SLAB SHALL BE INSTALLED A MINIMUM OF 8" ABOVE EXPOSED EARTH
AND AT LEAST 1" ABOVE SLAB ON METAL POST BASES. (EXCEPTION:
POSTS OR COLUMNS OF APPROVED WOOD WITH NATURAL RESISTANCE
TO DECAY OR TREATED WOOD). POSTS OR COLUMNS RESTING ON
CON-CRETE PIERS SURROUNDED BY EXISTING GRADE SHALL BE A
MINIMUM OF 8" ABOVE ADJACENT GRADE PER CBC (LATEST EDITION).
ALL ISOLATED INTERIOR AND EXTERIOR WOOD POSTS ATTACHED
DIRECTLY TO CONCRETE SHALL BE SECURED WITH SIMPSON 'ABU',
U.N.O.
17.PROVIDE 2x4 FLAT HEADERS AT ALL INTERIOR NON-BEARING OPENINGS
UP TO 36 INCHES IN WIDTH AND 4x4 HEADERS FOR OPENINGS 3 ft TO 6 ft
IN WIDTH.
18.PROVIDE MINIMUM 1/2" CLEARANCE (VOID SPACE) FROM TOP OF ALL
INTERIOR NON-BEARING PARTITIONS TO ROOF AND CEILING FRAMING
ABOVE.
19.ALL EXTERIOR WALLS ADJACENT TO VAULTED CEILINGS SHALL BE
BALLOON FRAMED WITH CONTINUOUS STUDS TO BOTTOM CHORD OF
TRUSS OR 2X RAFTER OR DOUBLE 2x TOP PLATE, U.N.O.
20.WHEN PLYWOOD SIDING IS USED AS AN EXTERIOR OR INTERIOR WALL
COVERING, PROVIDE SOLID BLOCKING AT ANY HORIZONTAL JOINTS
BETWEEN SOLE PLATE AND ANY TOP PLATE. "Z" BAR METAL SHALL BE
USED AT EXTERIOR HORIZONTAL JOINTS.
21.INSTALL FIREBLOCKS TO CUT OFF ALL HORIZONTAL AND VERTICAL
DRAFT OPENINGS BETWEEN TWO STORIES AND ROOF ATTIC SPACES.
FIREBLOCKS SHALL BE OF 2 INCH NOMINAL THICKNESS. LOCATION OF
FIREBLOCKS SHALL INCLUDE:
A.STUD WALLS AT FURRED SOFFITS, CEILING AND FLOOR LEVELS.
B.AROUND TOP, BOTTOM, SIDES AND ENDS OF SLIDING POCKET DOORS
C.BETWEEN STAIR STRINGERS AT TOP AND BOTTOM OF RUN AND
BETWEEN STUDS IN A WALL PARALLEL AND ADJOINING RUN OF STAIRS.
22.FASTENING OF MULTIPLE MEMBERS:
DOUBLE & TRIPLE JOISTS;
16d NAILS AT 12" O.C STAGGERED (BOTH SIDES FOR TRIPLES).
FOUR OR MORE JOISTS;
1/2" DIA. M.B's AT 18" O.C STAGGERED.
4X OR LARGER BEAMS;
1/2" DIA. M.B's AT 12" O.C STAGGERED.
23.ALL ROUGH OR RESAWN BEAMS ARE TO BE FREE OF GRADING STAMP
LABELS AND FREE OF HEART CENTER (FOHC).
24.ALL HANGING 2X JOISTS SHALL UTILIZE SIMPSON "LUS" HANGERS, U.N.O.
AND SIMPSON "IUS" FOR I-JOISTS, U.N.O.
25.ALL BEARING WALLS ON A WOOD FLOOR ARE TO BE SUPPORTED WITH
DOUBLE JOISTS OR SOLID BLOCKING, UNLESS NOTED OTHERWISE.
26.ALL BEAMS TO BE SUPPORTED WITH FULL BEARING STUDS OR POSTS,
U.N.O.
27.ROOF SHEATHING IS TO CONTINUE UNDER "CALIFORNIA FRAMING", TYP.
28.APPLY SHEAR WALL PLYWOOD PRIOR TO ALL BOX-OUTS, FUR-OUTS,
SOFFITS OR ANY OTHER FRAMING THAT MAY INTERRUPT CONTINUITY OF
PLYWOOD.
29.PROVIDE FURRING AS NEEDED TO ALIGN NON-SHEAR WALLS WITH
SHEAR WALLS.
30.PROVIDE 4X OR DOUBLE 2X MEMBERS UNDER SOLE PLATE NAILING LESS
THAN 4 in. O.C., U.N.O.
31.DOUBLE TOP PLATES w/MIN. 48 in. LAP SPLICES TO BE PROVIDED w/MIN.
(12) 16d COMMON NAILS PER TOP PLATE SPLICE U.N.O. PER PLAN.
SDPWS-2021/CBC 2022
MATERIAL 8 FRM'G
SIZE EDGE
NAILING 1,4
FIELD
16D
SILL
LAG5
TRANSFER
--
A.B.'S
9
5/8"VALUE
B 3/8" APA
SHEARWALL SCHEDULE
SINKER
WINDSEISMIC
CONFORMING TO ANSI/AF&PA
FRAMING
CLIP
LTP4/A35
3/8" APA 8d 6"12"4"12"--42"220 plf--307 plf24"
SILL
PLATE
2X4
MIN.
FOOTNOTES:
1.ALL NAILS TO BE COMMON NAILS.
2.SIMPSON LPT4 FRAMING ANCHOR MAY BE SUBSTITUTED AT FLAT CONDITIONS.
3.ALL STUDS, SILL PLATES AND BLOCKING TO BE 3X FRAMING.
4.SOLID BLOCKING SHALL BE PROVIDED AT ALL EDGES AND HORIZONTAL JOINTS.
5.SIMPSON STRONG TIE 1/4" SDS X 6" LONG LAG SCREWS.
6.PLYWOOD APPLIED TO BOTH SIDES SHALL BE OFFSET OR FRAMING SHALL BE 3X AND
NAILS ON EACH SIDE SHALL BE STAGGERED.
7.3X @ PANEL JOINTS; 2X FRMG AT TOP PLATES MAY BE USED PROVIDED FULL NAILING
WIDTH IS AVAILABLE TO ONE PIECE OF SHT'G; STAGGER NAILS 1/2" & SHT'G. ONE SIDE
ONLY.
8.SHEETS SHALL NOT BE LESS THAN 4FT BY 8FT, EXCEPT AT BOUNDARIES AND CHANGES
WHERE SHEET SHALL BE 24" MINIMUM.
9.SQUARE PLATE WASHERS SHALL BE USED WITH ALL ANCHOR BOLTS.
5 8" A.B. - 3" X 3" X 0.229"
3 4" A.B. - 3" X 3" X 0.229"
10.USE 4-1/2" SQ. X .229" AT 2X6 WALLS.
11.3X MUDSILL PLATES
12.IF WOOD STRUCTURAL PANEL SHEAR WALLS WITH ASPECT RATIO (h/bs) EXCEED 2:1,
SHEAR WALL CAPACITY SHALL BE REDUCED BY MULTIPLYING WITH 2bs/h FOR DESIGN.
NOTE:WHERE PANELS ARE APPLIED ON BOTH FACES OF A SHEAR WALL AND NAIL SPACING IS
LESS THAN 6 INCHES ON CENTER ON EITHER SIDE, PANEL JOISTS SHALL BE OFFSET TO
FALL ON DIFFERRENT FRAMING MEBERS. ALTERNATIVELY, THE WIDTH OF THE NAILED
FACE OF FRAMING MEMBERS SHALL BE 3" OR GREATER AT ADJOINING PANEL EDGES
AND NAILS AT ALL PANEL EDGES SHALL BE STAGGERED.
3X MIN.
STAGG'D
2X4 BLK. W/
16d @ 4" OC
SOLID RIM
OR BLK'G
SOLE PLATE CONNECTION TO FRAMING BELOW (1)
STD.
3XDESCRIPTION
A
RATED
RATED 8d 4"12"3"12"--36"320 plf--447 plf16"2X4
CAP.
VALUE
CAP.
C 3/8" APA
RATED 8d 3"12"3"8"--24"410 plfYES 575 plf12"2X4
7
STAGG.
D 3/8" APA
RATED 8d 2"12"2"6"--16"530 plfYES 742 plf10"2X4
7
STAGG.
E 15/32" APA
RATED 10d 2"12"4"--12"770 plfYES 1077 plf10"2X4
7 --
F 15/32"
STRUC. 1 10d 2"12"4"--12"870 plfYES 1217 plf8"2X47--
WD. PANEL
SPECIAL INSPECTION
B. HIGH-STRENGTH AND ANCHOR BOLTS
C. STEEL MOMENT FRAME CONNECTIONS
A. FIELD WELDING
D. EPOXY ANCHORS
(Continuous)
(Continuous)
E. STRUCTURAL MASONRY (AS NOTED)
(Continuous)
(Continuous)
(Sect. 1704.5.1.3)
F. STRUCTURAL PLYWOOD (<=4" O.C.)(Periodic)
G. CONCRETE (OVER 2500 psi)(Continuous)
H. POST-TENSION (WHEN OCCURS)(Continuous)
I. CAST-IN-PLACE CAISSONS (Continuous)
J. SOILS COMPLIANCE (Per Soils Report)
EXPOSURE
REQUIREMENTS FOR CONCRETE BY EXPOSURE CLASS
(ACI 318-19, Table 19.3.2.1)
CLASS
MAX.
W/C
MIN. F'c
(PSI)
ADDITIONAL REQUIREMENTS
AIR CONTENT LIMITS ON CEMENT. MAT'L.
EXPOSURE
CLASS
MAX.
W/C
MIN. F'c
(PSI)
CEMENTITIOUS MATERIAL TYPE
ASTM C150
S0 N/A 2,500
S1 0.50 4,000
S2 0.45 4,500
S3
0.45 4,500
ASTM C595 ASTM C1157
CALCIUM
CHLORIDE
------------
II
V
V+POZZOLAN
or SLAG
TYPE WITH (MS)
DESIGNATION
TYPE WITH (HS)
DESIGNATION
TYPES WITH (HS)
DESIGNATION + POZ
MS
HS
HS+POZZOLAN
or SLAG
---
NOT
PERMITTED
NOT
PERMITTED
EXPOSURE
CLASS
MAX.
W/C
MIN. F'c
(PSI)
W0 N/A 2,500
W1 N/A 2,500
NONE
26.4.2.2(d)
EXPOSURE
CLASS
MAX.
W/C
MIN. F'c
(PSI)
MAX. CHLORIDE ION CONTENT % BY WT.
REINFORCED CONC.
C0 N/A 2,500
C1 N/A 2,500
C2 0.40 5,000
RELATED
PROVISIONS
1.00 NONE
0.30
0.15
---
CONCRETE
COVER
PRESTRESSED CONC.
0.06
0.06
0.06
ADDITIONAL REQUIREMENTS
1,2
4
5,6
6
7
7 5
9,10
1,2
1,2
1,2
FREEZING/THAWING
SULFATE
IN CONTACT WITH WATER
CORROSION PROTECTION OF REINFORCEMENT
NOTES:
1.THE w/cm IS BASED ON ALL CEMENTITIOUS AND SUPPLEMENTARY CEMENTITIOUS MAT. IN THE
CONCRETE MIXTURE.
2.THE MAXIMUM w/cm LIMITS DO NOT APPLY TO LIGHTWEIGHT CONCRETE.
3.FOR PLAIN CONCRETE, THE MAXIMUM w/cm SHALL BE 0.45 AND THE MINIMUM F'c SHALL BE 4,500 PSI.
4.ALTERNATIVE COMBINATIONS OF CEMENTITIOUS MAT. TO THOSE LISTED ARE PERMITTED FOR ALL
SULFATE EXPOSURE CLASSES WHEN TESTED FOR SULFATE RESISTANCE AND MEETING THE CRITERIA
IN 26.4.2.2(c).
5.FOR SEAWATER EXPOSURE, OTHER TYPES OF PORTLAND CEMENTS WITH TRICALCIUM ALUMINATE
(C3A) CONTENTS UP TO 10 PERCENT ARE PERMITTED IF THE w/cm DOES NOT EXCEED 0.40.
6.OTHER AVAILABLE TYPES OF CEMENT SUCH AS TYPE I OR TYPE III ARE PERMITTED IN EXPOSURE
CLASSES S1 OR S2 IF THE C3A CONTENTS ARE LESS THAN 8 PERCENT FOR EXPOSURE CLASS S1 OR
LESS THAN 5 PERCENT FOR EXPOSURE CLASS S2.
7.THE AMOUNT OF THE SPECIFIC SOURCE OF THE POZZOLAN OR SLAG CEMENT TO BE USED SHALL BE
AT LEAST THE AMOUNT THAT HAS BEEN DETERMINED BY SERVICE RECORD TO IMPROVE SULFATE
RESISTANCE WHEN USED IN CONCRETE CONTAINING TYPE V CEMENT. ALTERNATIVELY, THE AMOUNT
OF THE SPECIFIC SOURCE OF THE POZZOLAN OR SLAG CEMENT TO BE USED SHALL BE AT LEAST THE
AMOUNT TESTED IN ACCORDANCE WITH ASTM C1012 AND MEETING THE CRITERIA IN 26.4.2.2(c).
8.IF TYPE V CEMENT IS USED AS THE SOLE CEMENTITIOUS MAT., THE OPTIONAL SULFATE RESISTANCE
REQUIREMENT OF 0.040 PERCENT MAXIMUM EXPANSION IN ASTM C150 SHALL BE SPECIFIED.
9.THE MASS OF SUPPLEMENTARY CEMENTITIOUS MAT. USED IN DETERMINING THE CHLORIDE CONTENT
SHALL NOT EXCEED THE MASS OF THE PORTLAND CEMENT.
10.CRITERIA FOR DETERMINATION OF CHLORIDE CONTENT ATRE IN 26.4.2.2.
11.CONCRETE COVER SHALL BE IN ACCORDANCE WITH 20.5.
3 3
W2 0.50 4,000 26.4.2.2(d)
OR SLAG
OPT.
1
0.40 5,000OPT.
2 V 8 TYPE WITH (HS)
DESIGNATION HS
NOT
PERMITTED
11
FLAT BLOCKING TO TRUSS AND WEB FILLER, FACE NAIL 16d COMMON @ 6" O.C.
2. CEILING JOIST TO TOP PLATE, TOENAIL EACH END 3-8d
3. CEILING JOIST LAPS (NON-PARALLEL CONDITION), FACE NAIL 3-16d
4. CEILING JOIST ATTACHED TO PARALLEL RAFTER, FACE NAIL TABLE 2308.7.3.1
5. COLLAR TIE TO RAFTER, FACE NAIL EACH RAFTER 3-10d
6. RAFTER/ROOF TRUSS TO PLATE, 2 TOENAILS & 1 TOENAIL PER SIDE 3-10d
7. RAFTER TO RIDGE/HIP/VALLEY, TOE NAIL 3-10d
RAFTER TO RIDGE/HIP/VALLEY, END NAIL 2-16d
8. STUD TO STUD (NON-BRACED WALLS), FACE NAIL 16d COMMON @ 24" O.C.
16d BOX @ 16" O.C.
9. STUDS AT CORNERS (BRACED WALLS), FACE NAIL 16d COMMON @ 16" O.C.
16d BOX @ 12" O.C.
10. BUILT-UP HEADER WITH 1/2" SPACER FACE NAIL 16d COMMON @ 16" O.C.
16d BOX @ 12" O.C.
4-8d
12. TOP PLATE TO TOP PLATE, FACE NAIL 16d COMMON AT 16" O.C.
10d BOX @ 12" O.C.
13. DOUBLE TOP PLATE SPLICE, FACE NAIL EACH SIDE 8-16d
14. BOTTOM PLATE TO RIM (NON-BRACED WALLS) FACE NAIL 16d COMMON AT 16" O.C.
16d BOX @ 12" O.C.
15. BOTTOM PLATE TO RIM (BRACED WALLS), FACE NAIL 2-16d
16. TOP/BOTTOM PLATE TO STUD, TOENAIL 4-8d
TOP/BOTTOM PLATE TO STUD, END NAIL 2-16d
17. TOP PLATE LAPS AT CORNERS/INTERSECTIONS, FACE NAIL 2-16d
18. 1" BRACE TO EACH STUD AND PLATE, FACE NAIL 2-8d
19. 1X6 SHEATHING TO BEARING, FACE NAIL 2-8d
20. 1X8 SHEATHING TO BEARING, FACE NAIL 3-8d
21. JOIST TO SILL/TOP PLATE/GIRDER, TOE NAIL 3-8d
22. RIM/BAND JOIST OR BLK'G TO SILL/TOP PLATE, TOE NAIL 8d COMMON @ 6" O.C.
8d BOX @ 4" O.C.
23. 1X6 SUBFLOOR TO EACH JOIST, FACE NAIL 2-8d
24. 2" SUBFLOOR TO JOIST OR GIRDER, FACE NAIL 2-16d
25. 2" PLANKS 2-16d AT EACH BEARING
26. BAND/RIM JOIST TO JOIST, END NAIL 3-16d
27. BUILT-UP GIRDERS AND BEAMS FACE NAIL 20d COMMON @ 32" O.C.
28. LEDGER STRIP SUPPORTING JOISTS, FACE NAIL 3-16d
29. BRIDGING TO JOIST, TOE NAIL 2-8d
11. CONTINUOUS HEADER TO STUD, TOE NAIL
BLOCKING BETWEEN RAFTER/TRUSS NOT AT T.P., EA. END, TOENAIL 2-8d
1. RAFTER/JOIST BLOCKING TO TOP PLATE, TOENAIL 3-8d
2-20d AT ENDS & SPLICE
1.THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL
VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING
STARTING ANY WORK. THE ENGINEER ( DONG ENG. ) SHALL BE NOTIFIED
OF ANY AND ALL DISCREPANCIES.
2.DIMENSIONING SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON
DRAWINGS. TYPICAL DETAILS AND GENERAL NOTES ARE MINIMUM
REQUIREMENTS TO BE USED WHEN CONDITIONS ARE NOT SHOWN
OTHERWISE.
3.NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER
GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE
SHOWN CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON
PROJECT.
4.ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE
2022 EDITION OF THE CALIFORNIA BUILDING CODE (CBC), AND ANY
OTHER REGULATING AGENCIES WHICH HAVE AUTHORITY OVER ANY
PORTION OF THE WORK, INCLUDING THE STATE OF CALIFORNIA DIVISION
OF INDUSTRIAL SAFETY, AND THOSE CODES AND STANDARDS LISTED IN
THESE NOTES AND SPECIFICATIONS.
5.APPROVAL BY THE INSPECTOR DOES NOT CONSTITUTE AUTHORITY TO
DEVIATE FROM THE PLANS AND/OR SPECIFICATIONS. ANY DESIGN
WHICH FAILS TO BE CLEAR OR IS AMBIGUOUS MUST BE REFERRED TO
THE ENGINEER (DONG ENG.) FOR INTERPRETATION OR CLARIFICATION.
6.SEE ARCHITECTURAL, ELECTRICAL AND MECHANICAL DRAWINGS FOR
PITS, TRENCHES, ROOF OPENINGS, DEPRESSIONS ETC. NOT SHOWN ON
STRUCTURAL DRAWINGS.
7.VIBRATION EFFECTS OF MECHANICAL EQUIPMENT HAVE NOT BEEN
CONSIDERED BY ENGINEER.
8.THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING,
TEMPORARY SUPPORTS, ETC. IS SOLE RESPONSIBILITY OF THE
CONTRACTOR, AND HAS NOT BEEN CONSIDERED BY THE ENGINEER
(DONG ENG.). THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF
THE STRUCTURE PRIOR TO THE APPLICATION OF ALL SHEAR WALLS,
ROOF AND FLOOR DIAPHRAGMS AND FINISH MATERIALS. HE/SHE SHALL
PROVIDE THE NECESSARY BRACING TO PROVIDE STABILITY PRIOR TO
THE APPLICATION OF THE AFOREMENTIONED MATERIALS. STRUCTURAL
OBSERVATION JOB SITE VISITS BY THE ENGINEER SHALL NOT INCLUDE
INSPECTION OF THE ABOVE ITEMS.
9.CONTRACTOR SHALL INVESTIGATE SITE DURING CLEARING AND
EARTHWORK OPERATIONS FOR FILLED EXCAVATIONS OR BURIED
STRUCTURES SUCH AS CESSPOOLS, CISTERNS, FOUNDATIONS, ETC.
IF ANY SUCH STRUCTURES ARE FOUND, THE ENGINEER (DONG ENG.)
AND THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY.
10.CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON
FRAMED FLOORS OR ROOF. LOAD SHALL NOT EXCEED THE DESIGN LIVE
LOAD PER SQUARE FOOT. PROVIDE ADEQUATE SHORING AND/OR
BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH.
11.CONSTRUCTION DOCUMENTS IDENTIFIED AS "BID SET" ON ANY OR ALL
SHEETS MAY BE SUBJECT TO REVIEW. THIS REVIEW MAY RESULT IN
CHANGES WHICH MAY BE MADE TO THE PLANS PRIOR TO THE ISSUANCE
OF THE FINAL CONSTRUCTION SET WHICH WILL CONTAIN NO "BID SET"
DESIGNATIONS. CONSTRUCTION DOCUMENTS IDENTIFIED AS "BID SET"
ARE NOT CONSTRUED AS BEING THE COMPLETED OR FINAL DRAWINGS
AND THEY SHOULD NOT IN ANY WAY BE USED AS SUCH.
12.ALL GUARD AND HANDRAILS SHALL BE DESIGNED TO WITHSTAND A
POINT LOAD OF 200 POUNDS APPLIED IN ANY DIRECTION AND AT ANY
POINT TO TOP RAIL. A 50 PLF LOAD IS REQUIRED AT 3-STORY AND
MULTI-FAMILY PROJECTS. IF OCCUPANT LOAD IS LESS THAN 50, A 20 PLF
LOAD MAY BE USED.
13.THESE PLANS ARE INTENDED SOLELY FOR THE USE OF THE OWNER FOR
CONSTRUCTION AND ARE EXPRESSLY NOT INTENDED FOR USE IN
MARKETING. EXTERIOR ELEVATIONS AND OTHER DETAILS ON THESE
PLANS ARE ONLY A REPRESENTATION AND MAY VARY SIGNIFICANTLY
FROM THE ACTUAL CONSTRUCTION.
14.SLAB-ON-GRADE REQUIREMENTS TO BE PER THE SOIL ENGINEERS
RECOMMENDATIONS SOLELY, U.N.O. THE SLAB-ON-GRADE IS A
NON-STRUCTURAL ITEM AND THEREFORE HAS NOT BEEN DESIGNED BY
THE STRUCTURAL ENGINEER, UNLESS NOTED OTHERWISE.
15.IN THE EVENT OF CONFLICT BETWEEN THE ARCHITECTURAL GENERAL
NOTES AND THE STRUCTURAL GENERAL NOTES (SHT S.0), THE MORE
STRINGENT REQUIREMENT SHALL GOVERN.
1.ALL REINFORCING SHALL BE ASTM A-615 GRADE 40 FOR #4 BARS AND
SMALLER. ALL REINFORCING SHALL BE ASTM A-615 GRADE 60 FOR #5
BARS AND LARGER. WELDED WIRE FABRIC TO BE ASTM A-185, LAP 1-1/2
SPACES, 9" MIN. FOR STRUCTURAL SLABS ALL REINFORCING #5 AND
LARGER TO BE ASTM A-615 GRADE 60
2.ALL BARS SHALL BE DEFORMED AS PER ASTM A615 / A615M.
3.ALL BARS SHALL BE CLEAN OF LOOSE FLAKY RUST, GREASE OR OR
OTHER MATERIALS LIKELY TO IMPAIR BOND.
4.ALL BENDS SHALL BE MADE COLD.
5.SPLICING OF #3-#6 BARS SHALL HAVE A MIN. LAPPING OF 30 DIA. OR 2'-0"
MIN. IN ALL CONTINUOUS REINFORCEMENT OF FOOTINGS AND
CONCRETE WALLS, EXCEPT AS NOTED ON PLANS. MASONRY
REINFORCEMENT SHALL HAVE LAPPINGS OF 40 DIA. FOR GRADE 40 AND
48 DIA. FOR GRADE 60 OR 2'-0" MIN., U.N.O.
6.ALL REINFORCING BARS SHALL BE ACCURATELY AND SECURELY PLACED
BEFORE POURING CONCRETE.
7.CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AT LEAST
EQUAL TO THE DIAMETER OF THE BARS. COVER SHALL BE AS FOLLOW:
1.SPECIAL INSPECTION IS REQUIRED PER CBC SECTION
109, 1704 & 1707 FOR THE FOLLOWING CONDITIONS:
1.ALL CONCRETE SHALL CONFORM TO THE LATEST EDITION OF THE
CALIFORNIA CRC CODE.
2.CONCRETE SHALL CONFORM TO "EXPOSURE CLASS" REQUIREMENTS OF
ACI 318-19 REFER TO SOILS REPORT FOR SOIL CONDITIONS.
3.ALL CEMENT SHALL CONFORM TO ASTM C-150, C-595 OR C-1157. USE
CEMENT TYPE ................................................ TYPE II
4.FINE AND COARSE AGGREGATE SHALL CONFORM TO ASTM C-33 FOR
STANDARD WEIGHT CONCRETE AND ASTM C-330 FOR LIGHTWEIGHT
CONCRETE.
5.CONCRETE FOR SLAB-ON-GRADE SHALL HAVE A MAX. SLUMP OF 5" PER
ASTM C-143 AND MAX. SLUMP OF 4" FOR FOOTINGS AND GRADE BEAMS,
U.N.O. READY-MIX CONCRETE SHALL BE MIXED AND DELIVERED PER ASTM
C-94.
6.DRYPACK SHALL BE COMPOSED OF ONE PART PORTLAND CEMENT TO NOT
MORE THAN THREE PARTS SAND.
7.ANCHOR BOLTS, HOLDOWN BOLTS, DOWELS, INSERTS, ETC. SHALL BE
SECURED INTO PLACE AND INSPECTED PRIOR TO POURING CONCRETE.
8.CONCRETE SHALL BE CURED BY KEEPING CONTINUOUSLY WET FOR
10-DAYS OR BY AN APPROVED CURING COMPOUND.
9.REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING
DRAWINGS FOR MISCELLANEOUS ITEMS TO BE CAST INTO CONCRETE AND
FLOOR STEPS, DEPRESSIONS, PITS, CURBS, ETC.
10.SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF EXPANSION JOINTS,
A/C PADS, SCORING, ETC. FOR CONCRETE WALKS AND SLABS.
11.ALL STRUCTURAL CONCRETE ...............................F'c = 3,000 PSI
ALL SLAB-ON-GRADE ............................................... F'c = 3,000 PSI
ALL CONTINUOUS FOOTINGS AND PADS ............. F'c = 3,000 PSI
ALL CONCRETE SHALL REACH MINIMUM COMPRESSIVE STRENGTH
28 - DAYS (MIN. W/C RATIO=0.5).
12.ALL CONCRETE WITH F'c GREATER THAN 2,500 PSI SHALL HAVE SPECIAL
INSPECTION PER SECTION 1704 & 1707 OF THE CALIFORNIA BUILDING CODE
(CBC 2022) UNLESS NOTED OTHERWISE.
F0 N/A 2,500 N/A N/A
F1 0.55 3,500 ACI 318-19 TABLE 19.3.3.3 N/A
F2 0.45 4,500 ACI 318-19 TABLE 19.3.3.3 N/A
F3 0.40 5,000 ACI 318-19 TABLE 19.3.3.3 ACI 318-19 TABLE 26.4.2.2(b)
1.ALL STRUCTURAL SAWN LUMBER SHALL BE GRADED BY ONE OF THE
FOLLOWING: W.C.L.I.B., W.W.P.A., N.L.G.A, or PS 20.
2.ALL WOOD BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE
TREATED DOUGLAS FIR (PTDF), U.N.O
3.HOLES FOR BOLTS SHALL BE BORED WITH A BIT 1/32" TO 1/16" LARGER
THAN THE NOMINAL BOLT DIAMETER.
4.ALL BOLTS SHALL BE RE-TIGHTENED PRIOR TO APPLICATION OF FINISH
MATERIALS (PLYWOOD, PLASTER, DRYWALL, INSULATION, ETC.)
5.STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, ETC. UNLESS
SPECIFICALLY NOTED OR DETAILED. CONTACT ENGINEER IF NOT
SHOWN.
6.2X SOLID BLOCKING SHALL BE PLACED BETWEEN JOISTS AND/OR
RAFTERS AT ALL SUPPORTS, EXCEPT WHEN LEDGERED (U.N.O.)
7.CROSS-BRIDGING SHALL BE PROVIDED AT 8'-0" O.C. MAX. FOR ALL 2X
FLOOR JOISTS OVER 10" IN DEPTH AND ALL 2X ROOF RAFTERS OVER 10"
DEPTH. USE SOLID BLOCKING OR AN APPROVED METAL TYPE BRIDGING.
8.ALL STRUCTURAL PLYWOOD SHALL BE A.P.A. RATED SHEATHING (OR
OSB) EXPOSURE 1 OR EXTERIOR UNLESS NOTED OTHERWISE AND
CONFORM TO DOC PS1 OR PS2. EACH SHEET SHALL BE IDENTIFIED BY
GRADE MARK OF D.F.P.A OR A.P.A.
9.ALL BOLTS BEARING ON WOOD SHALL HAVE STANDARD CUT WASHERS
UNDER HEAD AND NUT UNLESS NOTED OTHERWISE.
10.ALL METAL ANCHORS, FASTENERS AND CONNECTORS ETC. SHALL BE
FROM "SIMPSON STRONG-TIE" (TM). SUBSTITUTIONS MUST BE ICC-ESR
PRODUCTS AND PRE-APPROVED IN WRITING BY ENGINEER (DONG ENG.).
11.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR-LARCH (OR BTR.), 19%
MAX. MOISTURE CONTENT, OF THE FOLLOWING GRADES, U.N.O.:
2X4 STUDS (UP TO 10')..................... "STANDARD" OR BETTER
2X4 STUDS (OVER 10')......................NO.2 OR BETTER
2X PLATES & 3X PLATES.................. "CONSTRUCTION GRADE" OR BETTER
2X6 STUDS......................................... NO.2
2X JOIST............................................. NO.2
BEAMS AND STRINGERS
4X10 AND SMALLER.......................... NO.2
4X12 AND LARGER........................... NO.1
6X AND 8X........................................... NO.1
4x POST/TIMBERS AND LARGER .... NO.1
ROOF PLANKING AND DECKING...... COM.DEX.
BOARD SHTG. AND STRIPPING........ SUITABLE FOR INTENDED USE.
32.TOP PLATE BREAKS AND SPLICES SHALL OCCUR OVER A STUD OR POST.
33.PROVIDE SOLID BLOCKING BETWEEN PERPENDICULAR JOIST AT BEARING AND
AT SHEAR WALLS.
34.ALL EXPOSED BEAMS AND HEAVY TIMBER RECOMMENDED TO BE FREE OF
HEART CENTER (FOHC).
35.ALL ISOLATED POSTS AND BEAMS TO HAVE SIMPSON ABU's, PB's AND/ OR BC's
MINIMUM, UNLESS NOTED OTHERWISE.
36.ALL SIMPSON HDU, HTT, HDQ, HHDQ, AND CB HOLDOWNS TO BE FASTENED TO
4x4 POST MIN., U.N.O.
37. ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS ARE TO BE SECURED
WITH MIN. 5/8" DIA. x 12" ANCHOR BOLTS AT 72 in. O.C., U.N.O. MIN. (2) BOLTS PER
PIECE WITH (1) BOLT LOCATED NOT MORE THAT 12" OR LESS THAN 7 BOLT DIA.
FROM EACH END AND/OR SPLICE OF THE PIECE.
38.ALL INTERIOR NON-SHEAR WALLS TO BE SECURED WITH ICC-ESR APPROVED
SHOT PINS WITH CADMIUM WASHERS AT 32" O.C. PER MANUF. SPECS., U.N.O.
PROVIDE ANCHOR 6" FROM ALL CORNERS AND SPLICES.
39.ALL CONVENTIONAL FRAME PORTIONS OF STRUCTURE ARE TO BE
CONSTRUCTED PER CRC.
40.ALL SHOP DRAWINGS ARE TO BE REVIEWED BY THE GENERAL CONTRACTOR
AND THE ARCHITECT PRIOR TO SUBMITTAL FOR ENGINEER ( DONG ENG. )
REVIEW.
41.PROVIDE MIN. 2X6 RAFTERS AT 24" O.C. WITH MAX. SPAN OF 6'-0"± BRACED TO
FRAMING BELOW AT OVERSTACK ("CALIFORNIA") FRAMING.
42.PROVIDE DOUBLE 2X SOLE PLATES WITH PROGRESSIVE SOLE PLATE NAILING AS
SPECIFIED ON THE PLANS AT BOTH PLATES WHERE 1 1/2" LIGHT WEIGHT
CONCRETE IS USED AT THE FLOOR.
43.WHERE BOTH TOP PLATES ARE BROKEN, SPLICE WITH ST6224 MIN. U.N.O.
44.COMMON NAILS SHALL BE USED FOR ALL SHEATHING AND TOP PLATE SPLICES.
BOX NAILS MAY BE USED AT SOLE PLATE NAILING. ALL HARDWARE SHALL BE
INSTALLED WITH NAILS PER THE MANUFACTURERS SPECIFICATIONS AND
RECOMMENDATIONS.
45.ALL HEADERS SHALL BE FRAMED WITH A MINIMUM OF (1) 2X4 TRIMMER AND (1)
2X4 KING STUD AT EACH END, U.N.O.
46.AT ANY SOLE PLATES OR TOP PLATES CUT FOR PIPES, PROVIDE A .058" THICK
(16 1 GA.) AND 1 " WIDE PLATE ACROSS EACH SIDE OF OPENING WITH NOT LESS
THAN (6) 2 16d NAILS.
47.PROVIDE SOIL BLOCKING AT SOFFIT CEILINGS.
48.SHEAR SHALL BE CONTINUOUS FROM BOTTOM PLATES TO TOP PLATES., U.N.O.
49.STAIR STRINGER SHALL BE 2x12 DF#1 AT MAX. 16" O.C., U.N.O.
50.A SINGLE TOP PLATE IS PERMITTED PROVIDED THE PLATE IS ADEQUATELY TIED
AT JOINTS, CORNERS AND INTERSECTING WALLS BY AT LEAST THE EQUIVALENT
OF 3 IN, X 6 IN. X .036 IN. THICK GALVANIZED STEEL PLATE THAT IS NAILED TO
EACH WALL OR SEGMENT OF WALL BY (6) 8d NAILS OR EQUIVALENT.
51.FASTENERS IN CONTACT WITH PRESSURE TREATED OR PRESERVATIVE
TREATED LUMBER SHALL BE HOT DIPPED ZINC COATED GALVANIZED STEEL,
STAINLESS STEEL, SILICON BRONZE OR COPPER. EXCEPTION: PLAIN CARBON
STEEL FASTENERS IN SBX/DOT AND ZINC BORATE PRESERVATIVE-TREATED
WOOD IN AN INTERIOR, DRY ENVIRONMENT SHALL BE PERMITTED.
1.ALL SITE PREPARATION, EXCAVATION AND COMPACTION SHALL BE DONE UNDER THE
SUPERVISION OF THE SOIL ENGINEER.
2.SEPARATE PERMITS SHALL BE OBTAINED FOR ALL FENCES, PLANTERS AND WALLS, AS
REQUIRED.
3.PROVIDE NON-EXPANSIVE FILL AS REQUIRED TO LEVEL PAD.
4.SURFACE WATER WILL DRAIN AWAY FROM BUILDING. DRAINAGE SHALL BE 2% (MIN.) FROM
BUILDING TO SWALE LINE. SWALE SHALL DRAIN AT 1% (MIN.) FROM REAR OF BUILDING TO
STREET.
5.THERE SHALL BE NO UTILITY TRENCH NEAR THE BUILDING FOUNDATION WHICH EXTEND
DEEPER THAN A 45 DEGREE LINE PROJECTED DOWN AND AWAY FROM THE BOTTOM
OUTSIDE CORNER OF ANY FOOTING.
6.SLAB SUBGRADE REQUIREMENTS ARE NOT WITHIN THE SCOPE OF WORK AND/OR LIABILITY
OF ENGINEER ( DONG ENG. ). THE SUBGRADE CONFIGURATION SHOWN IN DETAIL 1/SD1 OR
THE POST-TENSION DETAILS REFLECT THE GENERAL RECOMMENDATIONS OF THE SOILS
ENGINEER, AND/OR THE SITE CONDITIONS. IT IS THE RESPONSIBILITY OF THE OWNER TO
REVIEW THE SLAB SUBGRADE CONFIGURATION WITH THE SOILS ENGINEER, AND
CONCRETE/FLOORING CONTRACTORS, FOR ADEQUATE MOISTURE PROTECTION. PLEASE
REFER TO THE SOILS REPORT FOR ADDITIONAL RECOMMENDATIONS. THE SUBGRADE
MOISTURE/VAPOR RETARADER SHALL MEET THE CONFORMANCE OF ASTM E1745 CLASS A or
B MATERIAL.
7.ALL HOLDOWN ANCHORS, POST BASES AND HOLDOWN BOLTS SHALL BE TIED INTO PLACE
PRIOR TO FOUNDATION INSPECTION.
8.PLACE 20'-0" REBAR IN FOUNDATION AT SERVICE LOCATIONS. STUB UP REBAR ABOVE THE
FLOOR BY ELECTRIC SERVICE METERS.
9.FOR THE LOCATION OF CONTROL JOINTS, REFER TO THE FOUNDATION PLAN. (ZIP STRIP OR
EQUAL). MINIMUM OF 20'-0" O.C. EACH WAY IS RECOMMENDED.
10.DRIVEWAY PAVING SHALL BE 4" PORTLAND CEMENT CONCRETE (5 SACKS MIN.), U.N.O.
11.FOR POST-TENSION SLAB, REFER TO APPROVED PLANS PREPARED BY OTHERS (WHEN
OCCURS).
12.MINIMUM SLAB REINFORCEMENT AND PAD REQUIREMENT SHALL CONFORM TO THE SOILS
ENGINEER'S RECOMMENDATIONS, U.N.O..
23/32" APA RATED STURD-I-FLOOR T&G EXP I WITH MIN. SPAN RATING OF 24" O.C.
REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE WITH 10d COMMON
NAILS AT 6" O.C. EDGES & BOUNDARIES, 12" O.C. FIELD.
USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING USING
ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
AS AN ALTERNATE TO 10D COMMON NAILS, THE FOLLOWING FASTNERS CAN BE
USED: GRABBER PLYWOOD SCREWS (ICC-ER-5280), OR SIMPSON STRONG-TIE QUICK
DRIVE SCREWS (ICC-ER-1472), MIN 2" LONG @ 6" O.C. B.S., @ 6" O.C. E.S. AND 12" O.C.
F.S.
15/32" APA RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. REFER TO
NER 108 FOR INSTALLATION AND CONDITIONS OF USE WITH 8d COMMON NAILS AT 6"
O.C. EDGES & BOUNDARIES, 12" O.C. FIELD..
NOTE: ALL STRUCTURAL RATED PANELS MUST BE STAMPED BY ONE OF THE
FOLLOWING APPROVED AGENCIES, APA, PFS/TECO OR PITTSBURG.
1.ALL GLUED LAMINATED MEMBERS SHALL BE MADE OF 1-1/2" DOUGLAS-FIR
LARCH (DF)LAMINATIONS, COMBINATION 24F-V4 PER AITC/APA (U.N.O.).
2.DESIGN VALUES: Fb=2400 PSI; Fv=240 PSI; E=1.8X106 PSI
3.INDUSTRIAL APPEARANCE GRADE PER APA-EWS SHALL BE USED, WITH A
MOISTURECONTENT BETWEEN 7 - 14 PERCENT, UNLESS NOTED OTHERWISE.
4.FABRICATOR SHALL BE A MEMBER OF AITC AND ALL FABRICATION SHALL BE
PERFORMED IN ACCORDANCE WITH AITC-A190.1 & ASTM-3737. LUMBER SHALL
BE MARKED WITH AN AITC or APA-EWS GRADE STAMP INDICATING
CONFORMANCE WITH ALL APPLICABLE SPECIFICATIONS AND REQUIREMENTS.
5.GLUED LAMINATED MEMBERS SHALL BE ACCOMPANIED BY A CERTIFICATE OF
INSPECTION. CONTRACTOR SHALL BEAR EXPENSES OF INSPECTION AND TESTS.
A CERTIFICATE OF INSPECTION SHALL BE SUBMITTED TO THE BUILDING
DEPARTMENT PRIOR TO INSTALLATION.
6.ALL GLUED LAMINATED BEAMS WILL HAVE A STANDARD CAMBER BASED ON A
RADIUS = 3500, UNLESS NOTED OTHERWISE.
7.PARALLAM PSL 2.0E BY I-LEVEL PER ESR-1387 & LARR-25202
f b = 2900 PSI; fv = 290 PSI; E = 2.0x106 PSI
TIMBERSTRAND LSL 1.55E BY I-LEVEL PER ESR-1387 & LARR-25202
f b = 2250 PSI; fv = 310 PSI; E = 1.55x106 PSI
MICROLAM LVL BY I-LEVEL PER ESR-1387 & LARR-25202
f b = 2600 PSI; fv = 285 PSI; E = 2.0x106 PSI
8.ALTERNATE ENGINEERED WOOD PRODUCTS MUST BE APPROVED IN WRITING
BY ENGINEER (DONG ENGINEERING) PRIOR TO INSTALLATION.
9.PROVIDE MULTIPLE 2x4 SQUASH BLOCKS UNDER BEARING POINT LOAD (POST)
(OR MSB) FROM ABOVE TO TOP PLATES BELOW AT FLOOR LEVEL.
10.I-LEVEL I-JOISTS PER ICC ESR#1533, RR#25538
LOUISIANA PACIFIC I-JOISTS PER ICC ESR#1130, RR#25176
BOISE CASCADE I-JOISTS PER ICC ESR#1336, RR#24999
ROSEBURG I-JOISTS PER ICC ESR#1251, RR#25439
11.PROVIDE DOUBLE I-JOISTS OR DOUBLE I-JOIST BLOCKS WHEN 16d SOLE PLATE
NAILING (SPN)
IS LESS THAN 4" O.C. AT SHEAR WALL ABOVE.
12.REFER TO I-JOIST MANUFACTURER SPECIFICATION FOR DRILLING OF HOLES
THRU I-JOIST WEB. NOTCHING OF I-JOIST FLANGE IS PROHIBITED.
NOTES: 1. COMMON NAILS SHALL BE USED (U.N.O.)
2. JOIST CAN BE EITHER SAWN LUMBER OR I-JOIST PER PLAN
(CBC 2022 TABLE 2304.10.2)
GENERAL
1.THE DEPICTIONS OF ALL MISCELLANEOUS FABRICATED METAL PRODUCTS SHOWN HEREON
ARE NOT INTENDED TO BE USED AS FABRICATION SHOP DRAWINGS. THE METAL FABRICATOR
SHALL BE RESPONSIBLE FOR ALL METAL FABRICATION DESIGNS IN ACCORDANCE WITH ALL
NATIONAL, STATE AND LOCAL CODES AND POLICIES AS WELL AS THE AMERICAN INSTITUTE OF
STEEL CONSTRUCTION (AISC) AND ANY OTHER INDUSTRY STANDARDS. ALL METAL
FABRICATION DESIGNS ARE TO BE SUBMITTED TO, AND APPROVED BY, THE LOCAL BUILDING
INSPECTION DEPARTMENT RESPONSIBLE FOR THE PROJECT PRIOR TO FABRICATION. ALL
DETAILS, DIMENSIONS, ETC., SHOWN HEREON ARE INTENDED TO BE SCHEMATIC AND THE
DESIGN IS TO BE VERIFIED WITH ALL AFFECTED FIELD CONDITIONS. SUBCONTRACTORS AND
THE REQUIREMENTS OF ALL GOVERNING AGENCIES AND FABRICATION STANDARDS.
FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH
"SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR
BUILDINGS", AISC, CURRENT EDITION. STEEL SHALL CONFORM TO ASTM A-992, U.N.O.
2.ALL STRUCTURAL STEEL MATERIALS AND CONSTRUCTION SHALL SONFORM TO THE
REQUIREMENTS SPECIFIED IN BUILDING CODE, CHAPTER 22 & REFERENCE.
MATERIALS
3.STEEL SHALL BE PRIMED WITH A RUST RESISTANCE PRIMER & SHOULD CONFORM TO ASTM
A36 (fy=36 ksi) AS A MINIMUM, UNLESS OTHERWISE NOTED. ALL W SHAPES TO BE ASTM A992.
(fy=50 ksi)
4.STEEL PIPE SHALL CONFORM TO ASTM A53, Grade B (Fy=35 ksi).
5.ROUND HSS TUBING SHALL CONFORM TO ASTM A500 Grade C (Fy=46 ksi).
6.RECTANGULAR AND SQUARE HSS TUBING SHALL CONFORM TO ASTM A500, Grade C (Fy=46 ksi).
7.ALL STRUCTURAL WELDING PROCEDURED AND MATERIALS SHALL CONFORM TO BUILDING
CODE, SECTION 2204.1. ALL WELDING SHALL BE BY THE SHIELD METAL ARC WELDING
PROCESS OR THE SUBMERGED ARC WELDING PROCESS USING E70XX-LOW HYDROGEN
ELECTRODES, UNLESS OTHERWISE NOTED.
8.ALL BOLTS FOR CONNECTIONS OF STEEL MEMBERS SHALL CONFORM TO BUILDING CODE,
SECTION 2204.2 & ASTM A325N, UNLESS OTHERWISE NOTED. HOLES FOR BOLTS SHOULD BE
DRILLED OR PUNCHED & SHALL BE 1/16" LARGER THAN BOLT DIAMETER.
9.PREFABRICATED STEEL MOMENT FRAMES PER MANUFACTURER. STEEL MOMENT FRAME
MANUFACTURER SHALL SUBMIT SHOP DRAWING, DESIGN CALCULATIONS, AND APPROVED
MOMENT FRAME TEST REPORT (ICC, IAMPO, OR TEST PER APPENDIX S OF AISC SEISMIC
PROVISION) TO DONG ENGINEERING FOR REVIEW.
WELDS
9. ALL SHOP WELDING AND FABRICATION MUST BE DONE IN A SHOP APPROVED BY A SPECIAL
INSPECTION AGENCY WHICH IS APPROVED BY THE BUILDING OFFICIAL. ALL FIELD WELDING
MUST BE PERFORMED BY A CERTIFIED WELDER AND A SPECIAL INSPECTOR SHALL
CONTINUOUSLY INSPECT ALL STRUCTURAL FIELD WELDING. BOTH SHALL BE APPROVED BY
THE BUILDING OFFICIAL.
RESTRICTIVE NOTICE
DATE REVISIONS
SHEET DESCRIPTION
PROJECT OWNER
PROJECT ADDRESS
STAMP
NO:
REVISIONS
DATE SIGNED: 2/17/25
THESE DESIGNS, DRAWINGS, AND
SPECIFICATIONS ARE THE EXCLUSIVE
PROPERTY OF DONG ENGINEERING.
THESE DRAWINGS CANNOT BE COPIED,
TRANSFERRED, OR REPRODUCED NOR
CAN ANY OTHER STRUCTURES BE BUILT
FROM THEM WITHOUT WRITTEN CONSENT.
SHEET
DE#:
TEL- 714-617-5979
GARDEN GROVE, CA 92841
7661 GARDEN GROVE BLVD.,
DONG ENGINEERING, INC.
INFO@DONGENGINEERING.COM
240140
GA
R
A
G
E
C
O
N
V
E
R
T
T
O
A
D
U
26
1
7
D
E
O
D
A
R
S
T
,
S
A
N
T
A
A
N
A
C
A
9
2
7
0
5
S.0
GENERAL NOTES
DETAIL SHEET NUMBER
DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION)
SYMBOLS LEGEND
SDX
X DETAIL NUMBER
EXISTING FOOTING
REBAR
NEW SLAB/ FOOTING
HOLDOWN SCHEDULE:
SHEAR PANEL LENGTH AND NUMBER.
SEE SW SCHED. FOR PANEL TYPE, MIN. 2x4 @ EA. END.
xx
x'-x"X
INDICATES HOLDOWN, SEE HOLDOWNS SCHEDULE
HDU2
HDU4
HDU5
HOLDOWNSYM.
HDQ8
POST SIZE
H3
H4
H5
4X
4X
4X
H8
REF. DETAIL
4/SD1
HDU11H9
HDU14H10
HDU8H7 6X
6X
6X
8X
1. HOLDOWN POST MINIMUM THICKNESS IS SHOWN ON SCHEDULE ABOVE.
ACTUAL HOLDOWN POST SIZE IS INDICATED ON PLAN.
HHDQ11H11 6X
HHDQ14H12 8X
FOUNDATION NOTES:
1. REFER TO S.0 SHEET FOR MORE INFO.
2. REFER TO DETAILS 4/SD1 FOR INSTALLATION OF HOLDOWNS.
3. FOUNDATION ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL
PLATE SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS
STEEL, SILICON BRONZE OR COPPER.
EXCEPTION: PLAIN CARBON STEEL FASTENERS IN SBX/ DOT AND ZINC BORATE
PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT SHALL BE
PERMITTED.
4. CONTRACTOR SHALL VERIFY ALL EXISTING FOOTINGS AND NOTIFY TO ENG. OF
RECORD FOR ALL DISCREPANCIES.
5. HOLDOWN ANCHORS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING THE
WALL FRAMING.
6. ALL HOLDOWN ANCHORS SHALL BE TIED IN PLACE PRIOR TO CALLING
FOUNDATION INSPECTION.
7. SEE DETAIL 12/SD2 FOR PLATE NOTCHING & BORING. FOR PIPING THRU SILL &
TOP PLATES OF SHEAR WALLS, CONTACT DONG ENGINEERING, INC.
8. THE HOLDOWN POST SIZE SHALL FOLLOW THE HOLDOWN SCHEDULE U.N.O.
9. ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS TO HAVE 5/8" DIA. X MIN.
12" ANCHOR BOLTS, MIN. 7" EMBEDMENT INTO CONCRETE FOOTING AT 72" O.C.
UNLESS NOTED OTHERWISE ON PLANS. ONE ANCHOR BOLT SHOULD BE LOCATED
MAX. 12" AWAY AND MIN. 4 1/2" FROM THE END OF THE SILL PLATES. MIN. (2) A.BS.
PER SILL PLATE/SHEAR PANEL. SILL PLATE UNDER SHEAR WALLS OF UP TO 4'-0" IN
LENGTH MUST BE CONTINUOUS.
10. ALL INTERIOR NON-SHEAR WALLS TO BE SECURED WITH SIMPSON PHNW
SERIES 0.145Ø PINS WITH A PENETRATION OF 1 1/4" INTO SLAB AT 16" O.C. TO BE
INSTALLED IN ACCORDANCE WITH ICC ESR-2138.
11. ANCHOR BOLTS AT SHEAR WALLS SHALL BE INSTALLED WITH PLATE WASHERS
OF MIN. 3" SQ. X 0.229" THICK BETWEEN SILL PLATE AND NUT. EDGE(S) OF PLATE
WASHERS SHALL BE 1/2" MAX. FROM INSIDE FACE OF SHEAR PANEL(S).
4'
-
0
"
A
A
B
8'-0"
A
6'-6"
AH3
H3
12"
8
SD1
8
SD1
3
SD1
2
SD1
3
SD1
PROVIDE RED GARD
WATERPROOFING AND CRACK
PREVENTION MEMBRANE
(ICC ESR#1413) OVER (E) 4" THK.
MIN. CONCRETE SLAB ON GRADE.
5
SD1
5
SD1
6
SD1
TYP.
(E) CONCRETE SLAB
TO BE REMAINED
(E) FOOTING, TYP.
4 x 6
4 x 6 4 x 6
4'
-
0
"
A
A
B
(E
)
8'-0"
A
6'-6"
A
44 44
(E)
(E)C1
(E)
(E
)
(E
)
(E)
(E) RIDGE
3
SD2
2
SD2
4
SD2
4
SD2
(E)
6
SD2
TYP.
SHEAR PANEL LENGTH AND NUMBER.
SEE SW SCHED. FOR PANEL TYPE, MIN. 2x4 @ EA. END.
X
SDX
DETAIL NUMBER DETAIL SHEET NUMBER
CALIFORNIA FRAMING
BEAM NUMBER, REFER TO CALCULATIONS.
LEGEND:
INDICATES EXISTING ROOF RAFTER
X
FRAMING NOTES:
6X6 INDICATES BEAM SIZE (DFL HEADER/DROP) U.N.O.
BEARING WALLS, SEE PLAN.
xx
x'-x"
XX
POST SIZE, SEE POST SCHEDULE.
INDICATES NEW CEILING JOISTS, SEE JOISTS TABLE
1. REFER TO STRUCTURAL GENERAL NOTES AND DETAIL SHEETS S.0 FOR
MORE INFORMATION.
3. HANGERS FOR FLUSH FRAMED MEMBERS SHALL BE SIMPSON STRONG-TIE
AS FOLLOWS U.N.O.:
2. ALL VERTICAL PIPES THROUGH PLATES AND/OR SOLID RIM BEAMS MUST
BE DRILLED CLEAN CUT W/ 1/16" TOLERANCE. DO NOT NOTCH OR CUT
PLATES.
- 2x4's @ 16" o.c. maximum 14'-0" height
- 2x6's @ 16" o.c. maximum 20'-0" height
5. BUILDING CODE 2308.9.1 BALLOON FRAMED WALLS (NON-BEARING) STUD
HEIGHTS:
6. BEARING STUD HEIGHTS:
- 2x4's @ 16" o.c. maximum 10'-0" height
- 2x6's @ 16" o.c. maximum 16'-0" height
4. THE FOLLOWING TRIMMER SCHEDULE SHOULD BE USED FOR HEADERS IN
BEARING WALLS, U.N.O. ON THE PLAN. REQUIRED TRIMMER MUST BE
APPLIED @ EACH END OF HEADER.
CLEAR SPAN, L
L ≤ 6'-0"6'-0" < L ≤ 10'-0" L ≥ 10'-0"
2 x 4 2-2 x 4 2-2X4 U.N.O. PER PLAN
CONSTRUCTION KEY NOTES:
7. DOUBLE TOP PLATE AT ALL SHEAR WALL LINES SHALL BE SPLICED PER
DETAIL 14/SD2.
ALIGN STUD(S) / POST(S) WITH UPPER FLOOR STUD(S) / POST(S)
AND PROVIDE SOLID BLOCKING BETWEEN FLOOR
PROVIDE SOLID BLOCKING UNDER GIRDER / BEAM.
LINE OF 2X BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER
U.N.O. SEE PLAN FOR NUMBER OF BAYS.
XPOST SCHEDULE:
POST SIZESYM.
24
224
324
26
226
2X4 STUD
(2)-2X4 BUNDLED STUD
(3)-2X4 BUNDLED STUD
2X6 STUD
(2)-2X6 BUNDLED STUD
326
44
46
66
(3)-2X6 BUNDLED STUD
4X4 POST
4X6 POST
6X6 POST
POST SIZESYM.
JOISTS TABLE:
MARK JOIST SPECIFICATIONS
C1 CEILING JOIST 2 x 8 DFL#2 @ 16" O.C.
LUS
FACE MOUNT TOP FLANGED
HANGER TYPEMEMBER
2X JOIST
4X, 6X, LSL or PSL
TJI I-JOIST
JB
HU W/ MAX.BA
IUS ITS
X
1
2
3
RESTRICTIVE NOTICE
DATE REVISIONS
SHEET DESCRIPTION
PROJECT OWNER
PROJECT ADDRESS
STAMP
NO:
REVISIONS
DATE SIGNED: 2/17/25
THESE DESIGNS, DRAWINGS, AND
SPECIFICATIONS ARE THE EXCLUSIVE
PROPERTY OF DONG ENGINEERING.
THESE DRAWINGS CANNOT BE COPIED,
TRANSFERRED, OR REPRODUCED NOR
CAN ANY OTHER STRUCTURES BE BUILT
FROM THEM WITHOUT WRITTEN CONSENT.
SHEET
DE#:
TEL- 714-617-5979
GARDEN GROVE, CA 92841
7661 GARDEN GROVE BLVD.,
DONG ENGINEERING, INC.
INFO@DONGENGINEERING.COM
240140
GA
R
A
G
E
C
O
N
V
E
R
T
T
O
A
D
U
26
1
7
D
E
O
D
A
R
S
T
,
S
A
N
T
A
A
N
A
C
A
9
2
7
0
5
S1
FOUNDATION PLAN
ROOF FRAMING PLAN
SCALE:
FOUNDATION PLAN
1/4" = 1'-0"
SCALE:
ROOF FRAMING PLAN
1/4" = 1'-0"
RESTRICTIVE NOTICE
DATE REVISIONS
SHEET DESCRIPTION
PROJECT OWNER
PROJECT ADDRESS
STAMP
NO:
REVISIONS
DATE SIGNED: 2/17/25
THESE DESIGNS, DRAWINGS, AND
SPECIFICATIONS ARE THE EXCLUSIVE
PROPERTY OF DONG ENGINEERING.
THESE DRAWINGS CANNOT BE COPIED,
TRANSFERRED, OR REPRODUCED NOR
CAN ANY OTHER STRUCTURES BE BUILT
FROM THEM WITHOUT WRITTEN CONSENT.
SHEET
DE#:
TEL- 714-617-5979
GARDEN GROVE, CA 92841
7661 GARDEN GROVE BLVD.,
DONG ENGINEERING, INC.
INFO@DONGENGINEERING.COM
240140
GA
R
A
G
E
C
O
N
V
E
R
T
T
O
A
D
U
26
1
7
D
E
O
D
A
R
S
T
,
S
A
N
T
A
A
N
A
C
A
9
2
7
0
5
SD1
STRUCTURAL DETAILS
111
REINF. STD. HOOK, LAP
SEE NOTE #1
11 1/ 2" CLEAR OR BARS MAY BE IN CONTACT IF WIRED TOGETHER.
d2CONDITION WHERE BARS OCCUR ON THE SAME PLANE.
NOTES:
1.LAP
-54 BAR DIAM. #10 THRU #11
-40 BAR DIAM. #8 THRU #9
-30 BAR DIAM. #5 THRU #7
2."D" = BEND DIAMETER 6" FOR #3
THRU #8; 8" FOR #9 THRU #11.
1'
2.1/2" MIN.
D/2
D/2
d
D/2
HOOK
6
1
1. 1 1/ 2" CLEAR OR BARS MAY BE IN
CONTACT IF WIRED TOGETHER.
2. CONDITION WHERE BARS OCCUR
ON THE SAME PLANE.
111
EXTERIOR FOOTING DETAIL
0'
-
8
"
0'
-
8
"
D
MI
N
.
MI
N
.
W
0'
-
3
"
CL
R
.
0'
-
4
"
MI
N
.
1VENNER WHERE OCCURS.FND~4
2EXTEND FOOTING AT VENEER.FND~5
32-#4 REBAR CONT. @ T & B (U.N.O.).FND~3
4CONC. SLAB.FND~1
5OPT. POUR JOINT (N/A @ MONO POUR) W/ #3 DOWELS @ 16" O.C. EMBED MIN. 12" ON FIRST POUR.6P.T.D.F. SILL PLATE W/ A.B. (OR ALT. MASA PER PLAN.
72X STUDS @ 16" O.C. (U.N.O.)
8SEE FOUNDATION PLAN FOR SUB-GRADE BELOW SLAB.
18''
18''DOWEL
FOOTING DIMENSIONS
# OF
STORIES
W
WIDTH
D
DEPTH
1
2
3
12''18''
15''18''
18''24''
F.G.
24"5"
1
3
/
4
"
TO
2
"
9(E) CONC. FOOTING
10(N) CONC. FOOTING
11#4 DOWELS @ 32" O.C. W/ SIMPSON SET-XP EPOXY, ESR-2509. PERIODIC SPECIAL INSPECTION IS REQUIRED
1. VENNER WHERE OCCURS.
2. EXTEND FOOTING AT VENEER.
3. 2-#4 REBAR CONT. @ T & B (U.N.O.).
4. CONC. SLAB.
5. OPT. POUR JOINT (N/A @ MONO POUR) W/
#3 DOWELS @ 16" O.C. EMBED MIN. 12" ON
FIRST POUR.
6. P.T.D.F. SILL PLATE W/ A.B. (OR ALT. MASA
PER PLAN.
7. 2X STUDS @ 16" O.C. (U.N.O.)
8. SEE FOUNDATION PLAN FOR SUB-GRADE
BELOW SLAB.
9. (E) CONC. FOOTING
10. (N) CONC. FOOTING
11. #4 DOWELS @ 32" O.C. W/ SIMPSON
SET-3G EPOXY, ESR-4057. PERIODIC
SPECIAL INSPECTION IS REQUIRED
NOTES:
- VAPOR BARRIER TO HAVE MIN. 6" LAP AT ALL
SEAMS PER MANUF. (U.N.O.).
- VERIFY ALL INFORMATION PER UPDATED
SOILS REPORT.
111
TYP. CONTROL JOINT
1CONC. SLAB PER PLAN2BULLNOSE EDGES
0'
-
1
"
1/8"
1. CONC. SLAB PER PLAN
2. BULLNOSE EDGES
NOTES:
-SEE DETAIL #1 FOR
INFORMATION NOT SHOWN.
-PROVIDE CONTROL JOINT AT
10'-0" EACH WAY (U.N.O.)
-PROVIDE SAW CUT WITHIN 24
HOURS OF POUR.
111
NON-BEARING WALL
1CONC. SLAB PER PLAN2SHOT PIN SEE SHEET S.0 FOR MORE INFORMATION.
NOTES:
-SEE DETAIL #1 FOR
INFORMATION NOT SHOWN.
1. CONC. SLAB PER PLAN
2. 2X TREATED SILL PLATE
WITH SIMPSON 2-1/2" SHOT
PIN PDPA250 @ 32" O.C.
PER (ICC ESR-2138).
SEE SHEET S.0 FOR MORE
INFORMATION.
1.POST PER PLAN
2.P.T.D.F SILL PLATE
3.CONT. FTG. REINF. PERP LAN
4.SIMP. HOLD DOWN PER PLAN, SEE TABLE BELOW FOR SSTB BOLT DIAMETER
AND EMBEDMENT
5.1- #4 REBAR 4'-0" LONG CENTERED ON SSTB BOLT. LOCATE APPROXIMATELY
3"-5" FROM TOP OF SLAB/ STEM WALL (OR FTG @ TWO-POUR SYSTEM). BEND
BAR DOWN INTO FTG. @ END OF CURB CONDITION. MAYBE FOUNDATION
REBAR; NOT POST-TENSIONED CABLE.
6.#4 HORIZ. @ 12' O.C. EA. WAY
7.HOLD DOWN BOLT THREADED ROD PER TABLE.
8.SIMP. HDU11/ HHDQ11 OR HDU14/ HHDQ14 PER PLAN, SEE TABLE BELOW FOR
THREADED ROD BOLT DIAMETER AND EMBEDMENT.
9.EDGE OF PAD FTG.
10.EDGE OF CONC. SLAB
11.EDGE OF CONT. FTG.
F.G.
SECTION
"A""A"
8"
"B
"
F.G.
W
D
HDU8*
SIMPSON
HOLDOWN
5/8"
7/8"
SSTB 24
SSTB 34
20 5/8"
28 7/8"
HOLD DOWN BOLT (TWO-POUR)
* SSTBL MODEL IS RECOMMENDED FOR HDU8 HOLD DOWN ON 2-2X AND 3X SILL PLATES.
3"
CL
R
.
THREADED ROD
d
"A
"
"A
"
"A""A"
PLAN
DIA.
1"
A36 THRD. ROD 4X6
X4 WALL
HOLD DOWN BOLT
HDU11
1"
BOLT
W/ 3"X3"X3/8"
PLATE @ BOTT.
A36 THRD. ROD
W/ 4"X4"X1/2"
PLATE @ BOTT.
POST
X6 WALL
6X6
4X6 6X6
4X8 6X8
MINIMUM
EMBEDMENT
(d)
12"
15"
A B
FOOTING
DIMENSIONS
16 1/2"
18"18"
15"
D
SIMPSON SSTB (PER ICC ESR-2611)
HDU2 5/8"SSTB 20 16 5/8"
le
B
HDU4 5/8"SSTB 24 20 5/8"
HDQ8*
NOTES:
-SEE PLANS FOR HOLDOWN TYPES.
-SEE DETAIL #1 FOR INFORMATION NOT SHOWN.
-REFER TO MANUFACTURER SPECIFICATIONS FOR INSTALLATION INFORMATION NOT
SHOWN.
-MAINTAIN MIN. EDGE DISTANCE OF 1.3/4" (MEASURED FROM EDGE OF CONCRETE TO
CENTERLINE OF BOLT).
-SIMPSON SSTB & SB CAST IN PLACE ANCHOR BOLTS PER ICC-ESR-2611.
-FOR NAILED OR SCREWED HOLD DOWNS, WHICH HAVE BEEN CONNECTED TO A 2X
STUD NEXT TO THE 4X (MIN.) POST, STITCH NAIL THE 2X TO THE POST W/ 16d @ 3" O.C.
STAGG. (2" O.C. STAGG. FOR HDU8). IF INSTALLED ON 2X POST ADJACENT TO 4X (MIN.)
POST, HDU11 AND HDU14 SHALL BE INSTALLED USING SDS-1/4"X4.1/2" IN PLACE OF
THOSE SPECIFIED FOR SOLID POST ATTACHMENT.
1 3/4"
MIN. TYP.
1 3/4"
MIN. TYP.
3"
CL
R
.
EM
B
E
D
W
SSTB BOLT INSTALLATION
@ SW @ INT. FTG/SLAB
SSTB BOLT INSTALLATION
@ SW @ EXT. FTG/SLAB
HDU5
111
TYPICAL HOLDOWN INSTALLATION
8HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
7HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
2HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
1HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
5HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
6HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
7HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
9HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
11HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW 10HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
1HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
2HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
4HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
5HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
3HOLDOWN AND ANCHOR BOLT PER SCHEDULE BELOW
MIN.
EMBED. (leB)
5/8"
7/8"
SSTB 24
SSTB 34
20 5/8"
28 7/8"
HOLD DOWN BOLT (MONO-POUR)
5/8"SSTB 20 16 5/8"
5/8"SSTB 24 20 5/8"
MIN.
EMBED. (leB)SSTB BOLT SSTB BOLTDIA.DIA.
HD.
CAPACITY
3075#
4565#
5645#
7870#
HD.
CAPACITY
SIMPSON
HOLDOWN
9535#
HHDQ11 11810#
HDU14 14390#
HHDQ14 13710#
111
(N) FOOTING TO (E) FOOTING
8"24"
1(E) CONC. SLAB & FOOTING.2(N) CONC. FOOTING.
3#4 DOWEL @ 24" O.C.FND~649/16" DIA. HOLE W/ SIMPSON "SET-XP" EPOXY.
(E) FDN.(N) FDN. FTG.
1. (E) CONC. SLAB & FOOTING.
2. (N) CONC. FOOTING.
3. #4 DOWEL @ 24" O.C.
4. 9/16" DIA. HOLE W/ SIMPSON "SET-3G" EPOXY PER ICC ESR-4057. SPECIAL
INSPECTION REQUIRED.
NOTES:
- SPRAY BONDING AGENT (INTRALOK OR SIM.) AT THE JOINT BETWEEN OLD
AND NEW CONCRETE PRIOR TO POURING NEW CONCRETE.
- WHEN APPLICABLE, VERIFY W/ POST TENSION ENG. FOR LOCATION OF
STRANDS WHEN PLACING DOWELS INTO EXISTING P.T. FTG.
DO NOT CUT STRANDS.
111
(N) FOOTING AT GARAGE HEADER
0'
-
8
"
0'
-
8
"
D
MI
N
.
MI
N
.
W
0'
-
3
"
CL
R
.
5EXTEND FOOTING AT VENEER.FND~5
42-#4 REBAR CONT. @ T & B (U.N.O.).FND~3
3(N) CONC. SLAB.
2P.T.D.F. SILL PLATE W/ A.B. (OR ALT. MASA PER PLAN.
12X STUDS @ 16" O.C. (U.N.O.)
6SEE FOUNDATION PLAN FOR SUB-GRADE BELOW SLAB.
F.G.7(E) CONC. SLAB.
1. 2X STUDS @ 16" O.C.
(U.N.O.)
2. P.T.D.F. SILL PLATE W/ A.B.
(OR ALT. MASA PER PLAN.
3. (N) CONC. SLAB.
4. 2-#4 REBAR CONT. @ T & B
(U.N.O.).
5. EXTEND FOOTING AT
VENEER.
6. SEE FOUNDATION PLAN
FOR SUB-GRADE BELOW
SLAB.
7. (E) CONC. SLAB.
8. (N) WEEP SCREED.
82X STUDS @ 16" O.C. (U.N.O.)
1 3/4" MIN.
111
ANCHOR BOLT WITH EPOXY
15/8" THREADED BOLT
22X STUD WALL PER PLAN.WALL~1
32X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL.W-2X4_R~1
4CONC. SLAB.FND~1
59/16" DIA. HOLE FILLED W/ SIMPSON "SET-XP" EPOXY TIE.FND~7
1. 5/8" THREADED BOLT
2. 2X STUD WALL PER PLAN.
3. 2X SOLE PLATE W/ 16d @ 6"
O.C. U.N.O., SEE NAILING PER
SHEARWALL SCHDL.
4. CONC. SLAB.
5. 9/16" DIA. HOLE FILLED W/
SIMPSON "SET-3G" EPOXY TIE
PER ICC ESR-4057.
WHEN APPLICABLE: VERIFY
W/ POST TESION ENGINEER
FOR LOCATION OF STRANDS
WHEN PLACING DOWELS
INTO EXISTING P.T. FTG. DO
NOT CUT STRANDS.
* INSTALL IN ACCORDANCE
WITH SIMPSON STRONG -TIE
RECOMMENDATIONS:
PERIODIC SPECIAL
INSPECTION REQUIRED.
12
"
1 3/4" MIN.
13
"
M
I
N
.
111
HOLDOWN ANCHOR BOLT WITH EPOXY
1SIMPSON HOLDOWN HDU, SEE PLANS FOR HOLDOWN TYPES.HD-HDU_F~
2SIMP. ATR A.B. W/ DIA. PER HOLDOWN SCHEDULE
32X STUD WALL PER PLAN.WALL~1
42X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL.W-2X4_R~1
5CONC. SLAB.FND~1
69/16" DIA. HOLE FILLED W/ SIMPSON "SET-XP" EPOXY TIE.FND~7
1. SIMPSON HOLDOWN HDU, SEE
PLANS FOR HOLDOWN TYPES.
2. SIMP. ATR 5/8" Ø F1554 GR. 36
A.B..
3. 2X STUD WALL PER PLAN.
4. 2X SOLE PLATE W/ 16d @ 6" O.C.
U.N.O., SEE NAILING PER
SHEARWALL SCHDL.
5. CONC. SLAB.
6. 9/16" DIA. HOLE FILLED W/
SIMPSON "SET-3G" EPOXY TIE.
WHEN APPLICABLE: VERIFY W/
POST TESION ENGINEER FOR
LOCATION OF STRANDS WHEN
PLACING DOWELS INTO EXISTING
P.T. FTG. DO NOT CUT STRANDS.
* INSTALL IN ACCORDANCE WITH
SIMPSON STRONG -TIE
RECOMMENDATIONS: SPECIAL
INSPECTION REQUIRED
* APPLY FOR MAX. CAP. 1088 LBS
UPLIFT LOAD.
RESTRICTIVE NOTICE
DATE REVISIONS
SHEET DESCRIPTION
PROJECT OWNER
PROJECT ADDRESS
STAMP
NO:
REVISIONS
DATE SIGNED: 2/17/25
THESE DESIGNS, DRAWINGS, AND
SPECIFICATIONS ARE THE EXCLUSIVE
PROPERTY OF DONG ENGINEERING.
THESE DRAWINGS CANNOT BE COPIED,
TRANSFERRED, OR REPRODUCED NOR
CAN ANY OTHER STRUCTURES BE BUILT
FROM THEM WITHOUT WRITTEN CONSENT.
SHEET
DE#:
TEL- 714-617-5979
GARDEN GROVE, CA 92841
7661 GARDEN GROVE BLVD.,
DONG ENGINEERING, INC.
INFO@DONGENGINEERING.COM
240140
GA
R
A
G
E
C
O
N
V
E
R
T
T
O
A
D
U
26
1
7
D
E
O
D
A
R
S
T
,
S
A
N
T
A
A
N
A
C
A
9
2
7
0
5
SD2
STRUCTURAL DETAILS
1ROOF TRUSS BY MFR., SEE PLAN.ROOF~13
22X BLK'G @ 48" O.C.WALL~73SIMPSON "DTC" @ 48" O.C. MAX.H-DTC~
4JOIST OR TRUSS BOTT. CHORD.4JOIST OR TRUSS BOTT. CHORD.
3SIMPSON "DTC" @ 48" O.C. MAX.H-DTC~
5NON BEARING WALL.
3/
4
"
,
T
Y
P
.
3/
4
"
,
T
Y
P
.
5NON BEARING WALL.
1. ROOF OR FLOOR SYSTEM OR TRUSSES BY MFR., SEE PLAN.
2. 2X BLK'G @ 48" O.C.
3. SIMPSON "DTC" @ 48" O.C. MAX.
4. JOIST OR TRUSS BOTT. CHORD.
5. NON BEARING WALL.
111
NON-BEARING WALL DETAIL
2-0" MIN.
PANEL WIDTH
1SHEARWALL PER PLAN, REFERS TO SHEARWALL SCHEDULE.
2EDGE NAIL (E.N.) SHEAR PANEL TO ALL PANEL EDGES.
3FIELD NAIL @ 12" O.C.
4KING STUD OR POST PER PLAN. E.N. SHEAR PANEL TO POST.
5TRIMMER WHERE OCCURS.
8INSTALL HOLDOWN ON KING STUD OR POST W/ EDGE NAILING.
1. SHEAR PANEL PER PLAN.
2. EDGE NAIL (E.N.) SHEAR
PANEL TO ALL SHEARWALL
EDGES.
WHEN PANEL EXTEND TO
TRIMMER, E.N. BOTH TRIMMER
AND KING STUDS.
3. FIELD NAIL @ 12" O.C.
4. 2X OR MULTIPLE KING STUD
PER FRAMING NOTE W/ 16d
@ 16" O.C. TO TRIMMER.
5. TRIMMER PER PLAN.
6. HEADER PER PLAN.
7. MIN. 3-16d TO END OF HEADER.
8. SIMPSON HOLDOWN
PER PLAN.
9.WHEN HOLDOWNS
CONNECTED TO KING STUD,
REPLACED SDS SCREWS W/
LONGER LENGTH TO GET 2 1/2"
PENETRATIONS TO TRIMMER.NOTES:
1. PROVIDE 3/8" EDGE DISTANCE FOR NAILS.
2. PROVIDE MIN. 2X BLK'G @ ALL PLYWOOD EDGES OR AS NOTED IN SHEAR SCHULE.
3. STAGGER NAILS THAT ARE SPACED 2" O.C.
4. FOR SPECIFIC SHEARWALL CONDITIONS, SEE PLAN & SCHEDULE.
5. NO CUTS OR HOLES IN SHEATHING WITHIN 16" OF CORNERS.
6. MAX. ACCUMULATED LENGTH OF OPENINGS SHALL NOT EXCEED 20% OF THE WALL
LENGTH. MAX. LENGTH OF EA. OPENING IS 4-1/2" IN ANY DIRECTION.
6TRIMMER WHERE OCCURS.
7KING STUD OR POST PER PLAN. E.N. SHEAR PANEL TO POST.
9INSTALL HOLDOWN ON KING STUD OR POST W/ EDGE NAILING.
111
SHEAR PANEL ASSEMBLY DETAIL
1BEAM PER PLAN.
1BEAM PER PLAN.1BEAM PER PLAN.
2DBL. TOP PLATE.
2DBL. TOP PLATE.2DBL. TOP PLATE.3SIMPSON STRAP MSTI36 OR ST6224 3SIMPSON STRAP MSTI36 OR ST6224
4SIMPSON (2)A35 @ TOP & BOTT.
4SIMPSON (2)A35 @ TOP & BOTT.
4SIMPSON (2)A35 @ TOP & BOTT.
5POST OR MULTI STUD PER PLAN.WALL~3
5POST OR MULTI STUD PER PLAN.5POST OR MULTI STUD PER PLAN.
6(3)16d EA. SIDE
6(3)16d EA. SIDE
7SILL PLATE.
1. BEAM PER PLAN.
2. DBL. TOP PLATE.
3. SIMPSON STRAP MSTI36
OR ST6224.
4. SIMPSON A34 AT EA.
SIDE OF BEAM AND POST
PER BEAM CONDITION.
5. POST OR MULTI STUD
PER PLAN.
6. 2X STUD EA. SIDE OF
BEAM W/ 16d @ 12" O.C.
STAGGERED TO POST.
ADD 3-16d EA. SIDE TO BM.
7. 2X SILL PLATE.
NOTE:
- ADD FILLER @ SIDE OF
BEAM AS NEEDED.
1BEAM PER PLAN.
2DBL. TOP PLATE.4SIMPSON (2)A35 @ TOP & BOTT.
4SIMPSON (2)A35 @ TOP & BOTT.
4SIMPSON (2)A35 @ TOP & BOTT.
5POST OR MULTI STUD PER PLAN.WALL~3
7SILL PLATE.
COND A: DROP BEAM COND B: TOP FLUSH BEAM
COND C: BOTTOM FLUSH BEAM COND D: SIDE FLUSH BEAM
111
BEAM POCKET DETAIL
111
TOP PLATE SPLICE TYP.
SEE TABLE
NAIL SPLICE:
STRAP SPLICE:
1FLOOR SYSTEM PER PLAN.FLOOR~7
2FLOOR SYSTEM PER PLAN.FLOOR~7
2FLOOR SYSTEM PER PLAN.FLOOR~7
3FLOOR SYSTEM PER PLAN.FLOOR~7
3FLOOR SYSTEM PER PLAN.FLOOR~7
5FLOOR SYSTEM PER PLAN.FLOOR~7
4FLOOR SYSTEM PER PLAN.FLOOR~74FLOOR SYSTEM PER PLAN.FLOOR~7
2FLOOR SYSTEM PER PLAN.FLOOR~73FLOOR SYSTEM PER PLAN.FLOOR~7
EQ.EQ.
EQ.
7FLOOR SYSTEM PER PLAN.FLOOR~7
EQ.
1. 16d @ 8" O.C. (5) MIN. EA. SIDE OF
SPLICE U.N.O. & PER TABLE BELOW.
2. 2X STUD WALL PER PLAN.
3. LOCATE STUD UNDER SPLICE OR
PROVIDE 2X BLKG. ATTACHED TO
ADJACENT STUD W/ (3) 16d EA. SIDE.
4. PLATE TO STUD NAILING PER
C.B.C. MIN REQUIREMENTS.
5. NUMBER OF NAIL SPECIFIED
BETWEEN SPLICING POINTS PER
TABLE BELOW.
6. SIMP. STRAP PER TABLE BELOW.
7. SIMP. STRAP ST6224.
NOTES:
- FULLY NAIL STRAP W/ 16d
SINKER OR 10d COMMON.
- NAIL SHALL BE STAGGERED
& AT LEAST 2 1/4" APART.
CAPACITY 1880#
A
2506#
B
3760#
CCONDITION
MIN. PLATE LAP
COMMON NAIL
4' - 0" MIN.
1 ROW (9) - 16d
4' - 0" MIN.
2 ROW (6) - 16d
6' - 0" MIN.
2 ROW (9) - 16d
STRAP MSTA30 ST 6224 MST48
NAIL
SPLICE
STRAP
SPLICE
6FLOOR SYSTEM PER PLAN.FLOOR~7
6FLOOR SYSTEM PER PLAN.FLOOR~7
℄ PANEL JOINT.
3/8" TYP.
℄ PANEL JOINT.
3/8" TYP.
OFFSET EDGE SUPPORT
OFFSET EDGE SUPPORT
1ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1
1ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1
2JOIST.32 x 4 W/ 16d @ 12" O.C.
42 x 4 FLAT W/ (2) 10d @ EA. END.
1. ROOF SHEATHING AND NAILING
PER NAILING SCHDL.
2. JOIST.
3. 2 x 4 W/ 16d @ 12" O.C.
4. 2 x 4 FLAT W/ (2) 10d @ EA. END.
111
BLOCKING AT EDGE SUPPORT
"W
"
M
A
X
.
"L" MAX.12" MIN.12" MIN.
EQ
.
EQ
.
1NOTCH LOCATION.2SIMPSON STRAP "MSTA36" W/ (11) 10d COMMON EA. END (STRAP NOT REQ'D AT SILL PLT.)3BORED HOLE.
1. NOTCH LOCATION.
2. SIMPSON STRAP "MSTA36" W/ (11)
10d COMMON EA. END (STRAP NOT
REQ'D AT SILL PLT.)
3. BORED HOLE.
NOTE:
ONLY ONE NOTCH OR HOLE ALLOWED PER
EA. STUD. ( EXCLUDING LET-IN BRACES).
2-2X TOP PLT.
2X OR 3X
SILL PLATE.
NOTCHES
MIN.
SPACING
BORED
HOLES
"L"
MAX.
"W"
MAX.
2X4 PLATE
2X6 PLATE
2X8 PLATE
6'-0"
6'-0"
6'-0"
3-1/2"
5-1/2"
5-1/2"
1-1/2"
2"
2"
1-1/4"
2"
3"
111
PLATE NOTCHING AND BORING
1PANEL BOUNDARY & BOUNDARY NAILING (B.N.) PER PLAN.
2FIELD NAILING PER PLAN.3CONTINUOUS PANEL EDGE, NO BLKG', E.N. PER PLAN.
1PANEL BOUNDARY & BOUNDARY NAILING (B.N.) PER PLAN.
4DISCONTINUOUS PANEL EDGE, E.N. PER PLAN.
5FRAMING @ 24" O.C. SHOWN (16" O.C. SIMILAR).
6DIRECTION OF FACE GRAIN PERPENDICULAR TO SUPPORT.
1. PANEL BOUNDARY & BOUNDARY
NAILING (B.N.) PER PLAN.
2. FIELD NAILING PER PLAN.
3. CONTINUOUS PANEL EDGE, NO
BLKG', E.N. PER PLAN.
4. DISCONTINUOUS PANEL EDGE,
E.N. PER PLAN.
5. FRAMING @ 24" O.C. SHOWN (16"
O.C. SIMILAR).
6. DIRECTION OF FACE GRAIN
PERPENDICULAR TO SUPPORT.
NOTES:
- STAGGER JOINTS AS SHOWN.
- MIN. SIZE OF SHEET SHALL BE
2 FT. x 2 FT.
- NAILS SHALL BE DRIVEN TIGHT
BUT SHALL NOT FRACTURE
SURFACE OF SHEATHING.
- TOLERANCE ON NAILING SHALL BE
3/4" W/ THE AVERAGE NAIL
SPACING OVER ANY 4 FT. LENGTH
BEING AT LEAST THAT NOTED ON
THE PLAN.
111
PLYWOOD SHEATHING LAYOUT
111
TYPICAL HEADER DETAIL
1HDR. PER PLAN.WALL~4
2(3) 16d COMMON FROM KING STUD TO HEADER, TYP.
3SIMPSON A35 @ T&B EA. END OF HEADER AT ALL EXTERIOR WALLS AT OPENINGS WIDER THAN 8'-0"
4SIMPSON LTP4 ALT. TO A35. INSTALL EA. SIDE OF HEADER.
5(2) 16d @ 2X4 WALL, (3) 16d @ 2X6 & 2X8 WALL.
1. HDR. PER PLAN.
2. (3) 16d COMMON FROM KING STUD TO HEADER, TYP.
3. SIMPSON A35 @ T&B EA. END OF HEADER AT ALL EXTERIOR
WALLS AT OPENINGS WIDER THAN 8'-0"
4. SIMPSON LTP4 ALT. TO A35. INSTALL EA. SIDE OF HEADER.
5. (2) 16d @ 2X4 WALL, (3) 16d @ 2X6 & 2X8 WALL.
±
±C.L.
4 2
53
1
6
ALT. TO VENT BLOCK
TYP.MAX.
±
±
C.L.
4 2
TYP.
MAX.
1. TYP. EDGE NAILING.
2. FOR VENT SPACING OF 6'-0"
(2-A35's PER ADJACENT BLK's.),
AND FOR VENT SPACING OF
4'-0" (3-A35's PER ADJACENT
BLK's.). SKIP A35's @ VENT
BLOCKING.
3. SCREEN FOR VENTILATION.
4. 8d COMMON EDGE NAILS :
@ 4" O.C. FOR VENT
SPACING OF 6'-0".
@ 3" O.C. FOR VENT
SPACING OF 4'-0".
5. ADJOINING FULL HT.
BLOCKING PER SHEAR
TRANSFER DETAILS.
6. (3) BAYS OF FLAT BLK'G.
CENTERED @ SCREEN.
111
TYPICAL VENT BLOCK
ROOF TRUSS CONDITION
ROOF CONVENTIONAL CONDITION
111
FIELD FIX FOR OPENING IN S.W.
2
1
3
4
1'
-
4
"
1'-4"
4"
5
NOTE:
- AVOID OPENING IN SHEAR WALLS W/
LENGTH LESS THAN 4'-0".
- MAX. WIDTH OF OPENING TO BE ONE
STUD BAY OR 14 1/2". DO NOT OVER-CUT
ANY FRAMING MEMBER.
- E.N. TO BLK'G. TO MATCH SHEAR WALL
E.N. UNLESS STRAP IS PLACED ON TOP
OF PLYWOOD.
- E.N. F.HT. ALONG STUD ON EACH SIDE
OF OPENING.
- IF OPENING IS LOCATED AT THE EDGE,
EXTEND STRAP INTO THE SHEAR WALL
TO MEET MIN. LENGTH REQUIRED.
1. 2X BLOCKING
2. SIMP. CS16X48" LONG W/ NAILS
@ 2-1/16" O.C.
3. ALT. LOCATION OF OPENING IF CONT.
SILL PLATE, NO "CS" STRAP REQUIRED
@ BOTTOM.
4. NO CUT OR HOLES IN SHT'G WITHIN
16" OF CORNERS.
5. OPENINGS OF MAX. 4 1/2"x4 1/2" DO
NOT NEED BLK'G/STRAP. DO NOT CUT
MORE THAN ONE OPENING IN ONE
HORIZONTAL LINE (AT ONE ELEVATION)
AND OFFSET OPENINGS BY MIN. 4"
VERT. SEE DETAIL 1/SN2 FOR
OPENINGS SMALLER THAN 4 1/2" x 4 1/2"
111
SHEAR TRANSFER
12X STUD PER PLAN.Wall~1
22X ROOF RAFTER PER PLAN.Roof~2
32X CEILING JOIST PER PLAN.Roof~3
4ROOF SHEATHING AND NAILING PER NAILING SCHDL.Roof~1
6SHEARWALL PER PLAN.Wall~2
7FRAMING CLIP A35 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-A35_L~1
8BOUNDARY NAILS.N-10d~
8BOUNDARY NAILS.N-8d~
1. (E) 2X STUD WALL.
2. (E) 2X ROOF RAFTER PER PLAN.
3. (N) 2X CEILING JOIST WHERE OCCURED.
4. (E) ROOF SHEATHING.
5. (E) DBL. TOP PLATE OR DROP BM PER PLAN.
6. (N) SHEARWALL WHERE OCCURRED.
7. (N) FRAMING CLIP A35 PER SHEARWALL
SCHDL. @ 48" O.C. MAX.
8. BOUNDARY NAILS.
9. (N) 6-16d COMMON NAILS @ EA. RAFTER AND
(N) CEILING JOIST.
5DBL. TOP PLATE OR DROP BM. PER PLAN.WALL~6
96-16d COMMON NAILS @ EA. RAFTER AND CEILING JOIST.ROOF~11
111
SHEAR TRANSFER
12X ROOF RAFTER PER PLAN.ROOF~2
22X CEILING JOIST PER PLAN.ROOF~3
32X CEILING JOIST OR BLK'G
42X STUD WALL PER PLAN.WALL~1 5(N) SHEARWALL WHERE OCCUR
6FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_BEND~1
7PROVIDE 2X STRUT @ 48" O.C. W/ A35 @ EA. END.
82 x 4 FLAT SPAN ACROSS MIN. 6 C.J. @ 8'-0" MAX.
9DBL. TOP PLATE.W-22X4~
10ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1
1. (E) 2X ROOF RAFTER
PER PLAN.
2. (N) 2X CEILING JOIST
PER PLAN.
3. (E) 2X BLK'G
4. (E) 2X STUD WALL PER PLAN.
5. (N) SHEARWALL PER PLAN
WHERE OCCUR.
6. FRAMING CLIP LTP4 PER
SHEARWALL SCHDL.
@ 48" O.C. MAX.
7. (E) 2X STRUT @ 48" O.C.
8. (N) 2 x 4 FLAT SPAN ACROSS
MIN. 6 C.J. @ 8'-0" MAX.
9. (E) DBL. TOP PLATE OR
DROP BM. PER PLAN.
10. (E) ROOF SHEATHING AND
NAILING PER NAILING SCHDL.
11. BOUNDARY NAILS.
11BOUNDARY NAILS.N-8d~
111
CONNECTION DETAIL
1(E) 2X STUD WALL.
2(N) 2X STUD WALL PER PLAN.
3(E) STUCCO TO BE REMAINED.
5(E) DRYWALL TO BE REMAINED.
4(N) STUCCO MATCH W/ (E) STUCCO.
6(N) DRYWALL MATCH WITH (E) DRYWALL.
8(E) HDR. TO BE REMAINED.
7(N) 2X PLATE W/ 10d COMMON NAIL @ 6" O.C. TO (E) HDR.
92X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL.WALL~5
1. (E) 2X STUD WALL.
2. (N) 2X STUD WALL PER
PLAN.
3. (E) STUCCO TO BE
REMAINED.
4. (N) STUCCO MATCH W/ (E)
STUCCO.
5. (E) DRYWALL TO BE
REMAINED.
6. (N) DRYWALL MATCH WITH
(E) DRYWALL.
7. (N) 2X PLATE W/ 10d
COMMON NAIL @ 6" O.C. TO
(E) HDR.
8. (E) HDR. TO BE REMAINED.
9. 2X SOLE PLATE W/ 16d @ 6"
O.C. U.N.O., SEE NAILING PER
SHEARWALL SCHDL.
12X ROOF RAFTER PER PLAN.Roof~2
2ROOF SHEATHING AND NAILING PER NAILING SCHDL.Roof~1
32X CEILING JOIST PER PLAN.Roof~342X STUD WALL PER PLAN.Wall~1
5SHEARWALL PER PLAN.Wall~2
62X LEDGER W/ 2-16d TO EA. STUDW-2X8~3
72X BEVELED BLK'G.Roof~4
8SIMPSON APPROVED HANGER PER PLAN.H-HU48_L~1
9FRAMING CLIP A35 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-A35_L~1
10SIMPSON HURRICANE CLIP H2.5A @ EA. TRUSS TO TOP PLATE.A-H2.5A_L~
1. (E) 2X ROOF RAFTER PER PLAN.
2. (E) ROOF SHEATHING AND NAILING
PER NAILING SCHDL.
3. (N) 2X CEILING JOIST PER PLAN.
4. (E) 2X STUD WALL PER PLAN.
5. (N) SHEARWALL WHERE OCCURED.
6. (N) 2X LEDGER W/ 2-16d TO EA. STUD
7. 2X BEVELED BLK'G.
8. SIMPSON APPROVED HANGER PER
PLAN.
9. FRAMING CLIP A35 PER SHEARWALL
SCHDL. @ 48" O.C. MAX.
10. SIMPSON HURRICANE CLIP H2.5A
@ EA. RAFTER TO TOP PLATE.
11. BOUNDARY NAILS.
12. DBL. TOP PLATE OR DROP BM. PER
PLAN.
13. SHEARWALL ALT. LOCATION.
11BOUNDARY NAILS.N-10d~
11BOUNDARY NAILS.N-8d~12DBL. TOP PLATE OR DROP BM. PER PLAN.WALL~6
111
SHEAR TRANSFER
13SHEARWALL ALT. LOCATION.
RESTRICTIVE NOTICE
DATE REVISIONS
SHEET DESCRIPTION
PROJECT OWNER
PROJECT ADDRESS
STAMP
NO:
REVISIONS
DATE SIGNED: 2/13/25
THESE DESIGNS, DRAWINGS, AND
SPECIFICATIONS ARE THE EXCLUSIVE
PROPERTY OF DONG ENGINEERING.
THESE DRAWINGS CANNOT BE COPIED,
TRANSFERRED, OR REPRODUCED NOR
CAN ANY OTHER STRUCTURES BE BUILT
FROM THEM WITHOUT WRITTEN CONSENT.
SHEET
DE#:
TEL- 714-617-5979
GARDEN GROVE, CA 92841
7661 GARDEN GROVE BLVD.,
DONG ENGINEERING, INC.
INFO@DONGENGINEERING.COM
240140
T2
4
G
A
R
A
G
E
C
O
N
V
E
R
T
T
O
A
D
U
26
1
7
D
E
O
D
A
R
S
T
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
5
RESTRICTIVE NOTICE
DATE REVISIONS
SHEET DESCRIPTION
PROJECT OWNER
PROJECT ADDRESS
STAMP
NO:
REVISIONS
DATE SIGNED: 2/13/25
THESE DESIGNS, DRAWINGS, AND
SPECIFICATIONS ARE THE EXCLUSIVE
PROPERTY OF DONG ENGINEERING.
THESE DRAWINGS CANNOT BE COPIED,
TRANSFERRED, OR REPRODUCED NOR
CAN ANY OTHER STRUCTURES BE BUILT
FROM THEM WITHOUT WRITTEN CONSENT.
SHEET
DE#:
TEL- 714-617-5979
GARDEN GROVE, CA 92841
7661 GARDEN GROVE BLVD.,
DONG ENGINEERING, INC.
INFO@DONGENGINEERING.COM
240140
T2
4
G
A
R
A
G
E
C
O
N
V
E
R
T
T
O
A
D
U
26
1
7
D
E
O
D
A
R
S
T
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
5
E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
GFCI
GFCI
CO/SD
GFCI
GFCI
GFCI
GFCI
R
R
R
R
3
GFCI
GFCI
GFCI
VS
R
R
3
EP
BEDROOM 2
BEDROOM 3
BEDROOM 4
MASTER BEDROOM
LIVING
HALL
DINING
KITCHEN
PORCH
BATH
LAUNDRY
LAUNDRY
CLOSET
N
E1
SHEET:
SCALE:
DATE:
11/25/2024
Revision Table
Number
Date
Revised By
Description
1
10/27/2023
JO
PLANNING
2
01/31/2024
JO
PLANNING
3
03/08/2024
JO
BP
4
04/02/2024
JO
PCC
5
11/25/2024
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
ELECTRICAL NOTES
1.) VERIFY CONNECTION POINTS FOR POWER TELEPHONE, GAS, SEWER AND CATV SYSTEMS
PRIOR TO CONSTRUCTION APPROXIMATE ONLY LOCATIONS INDICATED.
2.) NOTE: OPENINGS AROUND ELECTRICAL PENETRATIONS, FLOORS, CEILINGS, SHALL BE FIRE
STOPPED USING APPROVED METHONDS TO MAINTAIN THE FIRE RATING.
3.) NOTE: SMOKE DETECTORS SHALL BE LOCATED AT VAULTED CEILINGS
4.) PROVIDE AT LEAST TWO 20-AMPERE SMALL APPLIANCE BRANCH CIRCUITS TO SERVE TO
KITCHEN, BREAKFAST ROOM, AND DINNING ROOM. SUNCH CIRCUITS SHALL HAVE NO OTHER
OUTLETS.
5.) PROVIDE AT LEAST ONE 20-AMPERE BRANCH CIRCUIT TO SERVE LAUNDRY APPLIANCES
SUNCH CIRCUIT(S) SHALL HAVE NO OTHER OUTLETS.
6.) ALL ALUMINUM CONDUCTORS ARE PERMITTED ONLY IF SIZE 1/0 OR LARGE, AND ONLY TO
FEED MAIN OR SUB-PANELS, ALL OTHER CURRENT CARRYING CONDUCTORS SHALL BE
COPPER"
7.) "BONDS GROUNDING ELECTRODE TO METAL GAS AND WATER PIPING."
8.) SMOKE ALARMS SHALL BE 120-VOLT WITH BATTERY BACK-UP.
9.) PROVIDE 120-SMOKE ALARMS. LOCATED NO LESS THAN 3'-0" FROM AIR REGISTER. IN
DWELLING UNITS, A SMOKE ALARM SHALL BE INSTALLED IN EACH SLEEPING ROOM AND AT A
POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO EACH SEPARTATE
SLEEPING AREA. WHEN THE DWELLING UNIT HAS MORE THAN ONE STORY AND IN DWELLING
WITH BASEMENT, A SMOKE ALARM SHALL BE INSTALLED ON EACH STORY AND IN THE
BASEMENT. IN DWELLING UNIT WHERE A STORY BASEMENT IS SPLIT INTO TOW OR MORE
LEVELS, THE SMOKE ALARM SHALL BE INSTALLED ON THE UPPER LEVEL, EXCEPTTHAT WHEN
THE LOWER LEVEL CONTAINS A SLEEPING AREA, A SMOKE ALARM SHALL BE INSTALLED ON
EACH LEVEL. WHEN SLEEPING ROOMS ARE ON AN UPPER LEVLE, THE SMOKE ALARMS SHALL
BE PLACED AT THE CEILING OF THE UPPER LEVLE IN CLOSE PROXIMITY TO THE STAIRWAY. IN
DWELLING UNITS WHERE THE CEILING HEIGHT OF A ROOM OPEN TO THE HALLWAY SERIVE THE
BEDROOMS EXCEED THAT OF THE HALLWAY BY 24 INCHES OR MORE, SMOKE ALARMS SHALL
BE INSTALLE DIN THE HALLWAY AND IN THE ADJACENT ROOM. SMOKE ALARMS SHALL SOUND
AND ALARM AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING UNIT IN WHICH ARE LOCATED.
10.) PERMANENTLY WIRED SMOKE DETECTOR, 110V POWERED W/BATTERY BACK-UP INSIDE EACH
BEDROOM. (CEILING MOUNTED, U.N.O. ) NOTE: DETECTOR SHALL SOUND AN ALARM AUDIBLE
IN ALL SLEEPING AREAS OF THE UNIT.
11.) LIGHTING IN KITCHEN AND RESTROOM SHALL BE HIGH EFFICACY.
12.) SPECIFY ARC-FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL CIRCUITS SUPPLYING 125-
VOLT, SINGLE PHASE, 20 AMPERE RECEPTACLES IN BEDROOMS. RECEPTACLES LOCATED IN
BATHROOMS, GARAGES, OUTDOORS, KITCHENS (WHERE RECPTACLES SERVE COUNTER TOP
SURFACES), SINKS (WITHIN 6FT OF THE EDGE OF THE SINK), BATHTUB AND SHOWER STALLS
(WITHIN 6FT OF THE EDGE OF THE BATHTUB OR SHOWER STALL) AND LAUNDRY AREAS SHALL
HAVE GROUND FAULT CIRCUIT-INTURRUPTER (GFCI) PROTECTION.
13.ALL BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVCES (SUCH AS LIGHTS & SWITCHES)
INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS & AREAS SHALL BE PROVIDED WITH ARC-
FAULT CIRCUIT-INTERRUPTERS (AFCI) PROTECTION.
14.) ALL WALL SPACES, 2 FEET OR MORE IN WIDTH, SHALL HAVE RECEPTACLES INSTALLED SUCH
THAT NO POINT MEASURED HORIZONTALLY IS MORE THAN 6 FEET FROM A RECEPTACLE (12
FEET MAXIMUM SPACING.)
15.) COUNTERTOPS IN KITCHENS, PANTRIES, BRAKFAST ROOMS, DINDING ROOMS AND SIMILAR
AREAS SPACES 12 INCHES OF WIDER SHALL HAVE RECEPTACLES INSTALLED SUCH THAT NO
POINT ALONG THE WALL IS MORE THAN 2 FEET FROM A RECEPTACLE.
16.) AT LEASE ONE RECEPTALCE AT GRADE LEVEL SHALL BE INSTALLED IN BOTH THE FRONT
AND BACK OF EACH DWELLING UNIT.
17.) AT LEAST ONE RECEPTACLE, IN ADDITION TO THOSE FOR SPECIFIC EQUIPMENT, SHALL BE
INSTALLED IN THE FOLLOWING LOCATIONS.
A. IN EACH ATTACHED AND DETACHED GARAGE WITH ELECTRIC POWER. THE
BRANCH CIRCUIT SUPPLYING THIS RECEPTACLE SHALL NOT SUPPLY OUTLETS
OUTSIDE OF THE GARAGE. AT LEAST ONE RECEPTACLE OUTLET SHALL BE
INSTALLED FOR EACH CAR SPACE.
B. IN EACH ACCESSORY BUILDING WITH ELECTRIC POWER
C. IN EACH SEPARATE UNFINISHED PORTION OF A BASEMENT
18.) ALL NONLOCKING-TYPE 125-VOLT, 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED
TAMPER-RESISTANT
RECEPTACLES.
19.) IN CLOSETS, LUMINAIRES SHALL BE
(A) SURFACE-MOUNTED OR RECESSED INCANDESCENT OR LED WITH COMPLETELY
ENCLOSED LIGHT SOURCES,
(B)SURFACE MOUNTED OR RECESSED FLUORESCENT LUMINAIRES,
(C) SURFACE MOUNTED FLUORESCENT OR LED LUMNARIES IDENTIFIED AS SUITABLE FOR
INSTALLATION WITHIN STORAGE AREAS. MINIMUM CLEARANCES BETWEEN
LUMINARIAS AND THE NEAREST POINT OF STORAGE SPACE SHALL BE AS FLOLLOWS.
A. 12" FOR SURFACE MOUNTED INCANDESCENT OR LED LUMINARIES WITH COMPLETELY
ENCLOSED LIGHT
INSTALLED ON THE WALL ABOVE THE DOOR OR ON THE CEILING.
B. 6" FOR SURFACE MOUNTED FLUORESCENT LUMINARIAS INSTALLED ON THE WALL
ABOVE THE DOOR OR ON THE CEILING.
C. 6" FOR RECESSED INCANDESCENT OR LED LUMINARIES WITH A COMPLETELY
ENCLOSED LIGHT SOURCE INSTALLED IN THE WALL OR CEILING.
D. 6" FOR RECESSED FLUORESCENT LUMINARIES INSTALLED IN THE WALL OR CEILING.
E. SURFACE-MOUNTED FLUORESCENT OF LED LUMINARIES SHALL BE PERMITTED
TO BE INSTALLED WITHIN CLOSET STORAGE SPACE WHERE IDENTIFIED FOR THIS USE.
20.) ALL INSTALLED LUMINARIES SHALL BE HIGH- EFFICACY. HIGH EFFICACY LIGHT SOURCES
INCLUDE
A. PIN-BASED LINEAR OR COMPACT FLUORESCENT LAMPS (CFL) SOURCES USING ELECTRONIC
BALLASTS.
B. PULSE-START METAL HALIDE LAMPS.
C. HIGH PRESSURE SODIUM LAMPS.
D. GU-24 SOCKETS CONTAINING CFL OR LED LIGHT SOURCES.
21.) LUMINARIES RECESSED INTO CEILINGS SHALL MEET ALL OF THE FOLLOWING REQUIREMENTS
A. BE LISTED FOR ZERO CLEARANCE INSULATION CONTACT (IC).
B. HAVE A LABEL THAT CERTIFIES THE LUMINARIES IS AIRTIGHT WITH AIR LEAKAGE
LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM
E283.
C. BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINARIES HOUSING AND
CEILING AND SHALL HAVE ALL
AIR LEAK PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SEALED WITH A
GASKET OR CAULK.
D. FOR LUMINARIES WITH HARDWIRED BALLASTS OR DRIVERS, ALLOW BALLAST OR DRIVER
MAINTENANCE AND
REPLACEMENT TO BE READILY ACCESSIBLE TO BUILDING OCCUPANTS FROM BELOW THE
CEILING WITHOUT REQUIRING THE CUTTING OF HOLES IN THE CEILING.
E. SHALL NOT CONTAIN SCREW BASE SOCKETS.
F. SHALL CONTAIN LIGHT SOURCES THAT ARE MARKED "J8A-2016-E".
22.) EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM. LIGHTING
INTEGRAL TO AN
EXHAUST FAN MAY BE ON THE SAME SWITCH AS THE FAN PROVIDED THE LIGHTING CAN BE
SWITCHED OFF
WHILE ALLOWING THE FAN TO CONTINUE TO OPERATE FOR AN EXTENDED PERIOD OF TIME.
23.) IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINARIES
IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR.
24.) ALL JA8 COMPLAINT LIGHT SOURCES, EXCEPT THOSE IN CLOSETS LESS THAN 70 SQUARE
FEET AND THOSE IN
HALLWAYS, SHALL BE CONTROLLED BY DIMMERS OR VACANCY SENSORS. 150(K)2K & TABLE
150.0-A CEC) JA8
COMPLIANT LIGHT SOURCES INCLUDE LIGHT SOURCES IN CEILING RECESSED DOWNLIGHT
LUMINARIES AND
GU-24 SOCKETS CONTAINING LED LIGHT SOURCES
25.) ALL RESIDENTIAL OUTDOOR LIGHTING PERMANENTLY MOUNTED TO THE RESIDENCE OR
OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH-EFFICACY AND MEET THE FOLLOWING
REQUIREMENTS:
A. LIGHTS SHALL COMPLY WITH ONE OF THE TWO OPTIONS BELOW:
I. CONTROLLED BY A PHOTOCELL AND MOTION SENSOR. CONTROLS THAT OVERRIDE TO ON
SHALL NOT BE ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY REACTIVATES THE MOTION
SENSOR WITHIN 6 HOURS.
II. CONTROLLED BY (1) PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL OR (2)
ASTRONOMICAL TIME CLOCK OR (3) ENERGY MANAGEMENT CONTROL SYSTEM MEETING THE
REQUIREMENTS OF 150(K)3A.
B. LIGHTS SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT DOES NOT OVERRIDE
TO ON THE AUTOMATIC ACTIONS OF ITEM I OR ITEM II CHOSEN ABOVE.
26). ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS
OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING
ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED BY ANY
OF THE MEANS DESCRIBED IN 210.12(A)(1) THROUGH (6). AT KITCHEN COUNTER, INDICATE
COMBINATION AFCI/GFCI RECEPTACLES
27). SMOKE ALARMS AND CARBON MONOXIDE ALARMS TO BE INSTALLED (R314; R315) - PLEASE
SHOW LOCATION OF THE ALARM S ON THE PLANS. A. SMOKE ALARM: IN EACH SLEEPING ROOM.
(R314.3) B. SMOKE ALARM & CARBON MONOXIDE ALARM: OUTSIDE EACH SEPARATE SLEEPING
AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314.3; R315.3) C. SHEET E-1 -SPECIFY
UL217 FOR SMOKE DETECTOR AND UL2034/2075 FOR CARBON MONOXIDE DETECTOR ON PLAN.
28).RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS. IN ADDITION TO COMPLYING WITH
150.0(K)1A, LUMINAIRES RECESSED INTO CEILINGS SHALL MEET ALL OF THE FOLLOWING
REQUIREMENTS: A. BE LISTED, AS DEFINED IN SECTION 100.1, FOR ZERO CLEARANCE INSULATION
CONTACT (IC) BY UNDERWRITERS LABORATORIES OR OTHER NATIONALLY RECOGNIZED TESTING/
RATING LABORATORY; AND B. HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH
AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM
E283. AN EXHAUST FAN HOUSING SHALL NOT BE REQUIRED TO BE CERTIFIED AIRTIGHT; AND C. BE
SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING, AND HAVE
ALL AIR LEAK PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SEALED WITH A
GASKET OR CAULK; AND D. SHALL NOT CONTAIN SCREW BASE SOCKETS.
29). TANK-LESS - PROVIDE A DEDICATED 125 VOLT, 20 AMP ELECTRICAL GFCI RECEPTACLE
CONNECTED TO THE ELECTRICAL PANEL WITH A 120/240 VOLT 3 CONDUCTOR 10 AWG COPPER
BRANCH CIRCUIT, WITHIN 3 FEET OF THE WATER HEATER AND ACCESSIBLE TO THE WATER
HEATER. (CENERGYC 150.0(N)(1)(A))
30) ALL LED LUMINAIRES ARE REQUIRED TO BE CONTROLLED BY A NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION (NEMA) SSL-7A-COMPLIANT DIMMER UNLESS THEY ARE
CONTROLLED BY A VACANCY SENSOR OR AN OCCUPANCY SENSOR. THE COMBINED USE OF
NEMA SSL-7A-COMPLIANT DIMMER WITH LED LUMINAIRES CAN ENSURE FLICKER FREE
OPERATION WHEN THE LUMINAIRE IS DIMMED. PLEASE SHOW DIMMER SWITCH(ES) ON THE
PLANS. (2019 RESIDENTIAL COMPLIANCE MANUAL 6.3.1(G))
(N) ELECTRICAL PLAN
SCALE: 3/16" = 1'-0"
ELECTRICAL PLAN &
NOTES
(E) POWER POLE
(E) POWER METER
3/16" = 1'-0"
(N) SUB-PANEL
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
N
4:12
4:12
4:12
4:12
4:12
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / LP / L
30X22
ATTIC
ACCESS
62'-5"
26'-1"
21'
18'-2"
7'-2"
52'-2"
7'-4"
34'
47'-1"
26'-1"
52'-2"
12'
1'
1'
MC1
SHEET:
SCALE:
DATE:
11/25/2024
Revision Table
Number
Date
Revised By
Description
1
01/31/2024
JO
PLANNING
2
03/08/2024
JO
BP
3
04/02/2024
JO
PCC
4
11/25/2024
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
(E) ROOF PLAN &
MECHANICAL PLAN
SCALE: 1/8" = 1'-0"
(E) ROOF PLAN &
MECHANICAL PLAN
(E) ASPHALT SHINGLE
4
1
2
3
INTAKE LOW PROFILE VENT
SHADOWHAWK - LOW PROFILE VENT LPG12
EXHAUST SHINGLE VENT
5ATTIC VENT CALCULATION
MECHANICAL NOTES
1.) DUCTS PENETRATING WALL OR CEILING SEPARATIONS BETWEEN A GARAGE AND A DWELLING UNIT SHALL
BE CONSTRUCTED OF MINUM 26 GAGE SHEET METAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE.
2.) EACH BATHROOM CONTAINING A BATHTUB, SHOWER OR TUB/SHOWER COMBINATION SHALL BE
MECHANICALLY VENTILATED FOR PURPOSES OF HUMIDITY CONTROL IN ACCORDANCE WITH CMC, CHAPTER 4
AND CGBSC, CHAPTER 4, DIVISION 4.5 HUMIDITY CONTROL SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A
RELATIVE HUMIDITY RANGE OF LESS THAN OR EQUAL TO 50% TO A MAXIMUM OF 80%.
3.) A COMPRESSOR OR PORTION OF A CONDENSING UNIT SUPPORTED FROM THE GROUND SHALL REST ON A
CONCRETE OR OTHER APPROVED BASE EXTENDING NOT LESS THAN 3 INCHES ABOVE THE ADJOINING
GROUND LEVEL.
4.) CONDENSATE LINES FROM MECHANICAL EQUIPMENT SHALL DISCHARGE TO A PLUMBING FIXTURE OR
STORM DRAIN BY MEANS OF AN INDIRECT WASTE PIPE. CONDENSATE LINES SHALL NOT DRAIN OVER A
PUBLIC WAY.
5.) HOUSEHOLD COOKING APPLIANCES SHALL HAVE A VERTICAL CLEARANCE ABOVE THE COOKING TOP OF NOT
LESS THAN 30 INCHES TO COMBUSTIBLE MATERIAL OR METAL CABINETS.
6.) A. THE DISTANCE FROM THE PASSAGEWAY ACCESS TO THE FURNACE SHALL NOT EXCEED 20 FEET
MEASURED (FOR HEAD HEIGHT LESS THAN 6 FEET) ALONG THE CENTERLINE OF THE PASSAGEWAY.
B. THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE SOLID FLOORING NOT LESS THAN 24 INCHES
WIDE FROM THE ENTRANCE OPENING TO THE APPLIANCE.
C. A LEVEL WORKING PLATFORM NOT LESS THAN 30 INCHES BY 30 INCHES SHALL BE PROVIDED IN FRONT OF
THE SERVICE SIDE OF THE APPLIANCE
D. A PERMANENT 120-VOLT RECEPTACLE OUTLET AND A LIGHTING FIXTURE SHALL BE INSTALLED NEAR THE
APPLIANCE. THE SWITCH CONTROLLING THE LIGHT SHALL BE LOCATED NEAR THE ENTRANCE TO THE
PASSAGEWAY
7. ) A COMPRESSOR OR PORTION OF A CONDENSING UNIT SUPPORTED FROM THE GROUND SHALL REST ON A
CONCRETE OR OTHER APPROVED BASE EXTENDING NOT LESS THAN 3 INCHES ABOVE THE ADJOINING GROUND
LEVEL
8.) A SEDIMENT TRAP IS TO BE PROVIDED AT THE LOCATION OF THE WATER HEATER AND THE FAU OR WHERE A
SEDIMENT TRAP IS NOT INCORPORATED AS PART OF THE APPLIANCE. A SEDIMENT TRAP MUST BE INSTALLED
DOWNSTREAM OF THE APPLIANCE SHUTOFF VALVE AS CLOSE TO THE INLET OF THE APPLIANCE AS PRACTICAL,
BUT BEFORE THE FLEX CONNECTOR, WHERE USED AT THE TIME OF APPLIANCE INSTALLATION. SEDIMENT TRAPS
ARE NOT REQUIRED AT RANGES, CLOTHES DRYERS, DECORATIVE VENTED APPLIANCES, OR GAS FIREPLACES.
9.) CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED SO THAT THE ACTIVATION OF ONE ALARM ACTIVATES
ALL OF THE ALARMS. (CRC R315.7)
10.) REFRIGERANT SERVICE PORTS LOCATED OUTDOORS SHALL BE FITTED WITH LOCKING-TYPE TAMPER-
RESISTANT CAPS\ (CMC 1106.14)
11) LAUNDRY CLOSET
A. PROVIDE CLOTHES DRYER MOISTURE EXHAUST DUCT (MIN, 4INCH DIA. MADE OF METAL WITH SMOOTH INTERIOR
SURFACE) THAT TERMINATES TO THE OUTSIDE AND EQUIP WITH A BACK - DRAFT DAMPER. EXHAUST DUCT LENGTH
IS LIMITED TO 14 FT. WITH 2 ELBOWS SHOW THE DUCT AND TERMINATION LOCATION ON THE PLANS. (CMC 504.3).
B. PROVIDE 1SQ. INCH PER 1,000 BTU/hr. GAS APPLIANCE INPUT RATING (100 SQ. IN. MINIMUM) OF MAKEUP AIR TO
LAUNDRY ROOM PER CMC 504.3.2 & CMC 701.3.1. PROVIDE ANALYSIS ON THE PLANS TO JUSTIFY SIZE.
12) KITCHEN RANGE HOODS - SHALL BE INSTALLED FOR COOKING FACILITIES WITH AN APPROVED FORCED - DRAFT
SYSTEM OF VENTILATION VENTED TO THE OUTSIDE OF THE BUILDING. DUCTS USED FOR DOMESTIC KITCHEN
RANGE VENTILATION SHALL BE OF METAL, OR OTHER APPROVED MATERIAL AND SHALL HAVE SMOOTH INTERIOR
SURFACES. DUCTS FOR DOMESTIC RANGE HOODS SHALL ONLY SERVE COOKING APPLIANCES. (CMC 504.3; §
150.0(o)1G, 2B)).
A) KITCHEN VENTED RANGE HOODS -
i. HERS VERIFICATION OF AIRFLOW AND SOUND RATINGS.
ii. MINIMUM AIRFLOW OF 280 CFM.
iii. MAXIMUM SONE RATING OF 3.0.
13) BATHROOM EXHAUST FAN(S) SHALL BE OF THE FOLLOWING:
A)MIN 50 CFM.
B) ENERGY STAR COMPLIANT.
C) BE DUCTED TO TERMINATE OUTSIDE THE BUILDING.
D) BE RATED FOR SOUND AT A MAXIMUM OF 3 SONE.
E) SWITCHED SEPARATELY FROM LIGHTING.
EXHAUST SHINGLE VENT
EXHAUST ROOF VENT
(N) ROOF EXHAUST
VENTS.
PROVIDE MIN. OF 2
PER CALCS
2
MC1
2
MC1
(N) ROOF LOW
PROFILE INTAKE
VENTS.
PROVIDE MIN. OF 3
UNITS
1
MC1
1
MC1
ATTIC VENT CALCULATION :
387 SQ. FT / 300= 1.29 * 144= 185.76 SQ. IN.
AIR VENT INC. VENTS ARE SHOW AS REFERENCE ONLY,
SIMILAR VENTS CAN BE USED AS LONG AS IT MEETS THE INCHES NET FREE PER LINEAR FOOT REQUIRED
1/8" = 1'-0"
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
THE KITCHEN EXHAUST HOOD
SHALL PROVIDE A MINIMUM
AIRFLOW RATE OF 280 CFM, AS
PER CEnC TABLE 150.0-G, FOR
A FLOOR AREA OF 430 SQ. FT.
SEE NOTE 12 FROM
MECHANICAL NOTES.
WH
S
S
S
S
S
S
S
S
S
S
S
S
S
S
C / W
C / W
C / W
C / W
C / W
C / W
C / W
C / W
C / W
C / W
C / W
C / W
C / W
C / W
C / W
C / W C / W
C / W
C / W
C / W
H / W
H / W
H / W
H / W
H / W
C / W C / W
C / W
C / W
N
PB1
SHEET:
SCALE:
DATE:
04/15/2025
Revision Table
Number
Date
Revised By
Description
1
10/27/2023
JO
PLANNING
2
01/31/2024
JO
PLANNING
3
03/08/2024
JO
BP
4
04/02/2024
JO
PCC
5
11/25/2024
JO
PCC
6
04/15/2025
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
PLUMBING NOTES
1.) WATER CLOSETS SHALL HAVE AN AVERAGE WATER CONSUMPTION OF NOT MORE THAN
1.28 GALLONS PER FLUSH.
2.) SHOWER HEADS SHALL HAVE A WATER FLOW NOT TO EXCEED 1.8 GALLONS PER MINUTE
AT 80 PSI.
3.) THE MAXIMUM FLOW RATE OF LAVATORY FAUCETS SHALL NOT EXCEED 1.2 GALLONS
PER MINUTE AT 60 PSI.
4.) FAUCETS IN KITCHENS SHALL HAVE A WATER FLOW NOT TO EXEED 1.8 GALLONS PER
MINUTE AT 60 PSI AND MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM
RATE, BUT NOT EXCEED 2.2 GALLONS PER MINUTE, AND MUST DEFAULT TO A MAXIMUM
FLOW RATE OF 1.8 GALLONS PER MINUTE.
5.) GAS WATER HEATER SHALL HAVE ALL THE FOLLOWING COMPONENTS:
A. A 120V ELECTRICAL RECEPTACLE WITHIN 3 FEET FROM THE WATER HEATER AND
ACCESSIBLE WITH NO OBSTRUCTIONS.
B. A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE BETWEEN OUTSIDE
AND WATER HEATER.
C. A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF
THE INSTALLED WATER HEATER AND
ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE.
D. A GAS SUPPLY LINE WITH A CAPACITY OF AT LEAST 200,000 BTU/HR.
6.) APPLIANCES IN ATTICS SHALL BE ACCESSIBLE THROUGH AN ACCESS OPENING AT
LEAST A 22x30 INCH. THE APPLIANCE SHALL NOT BE MORE THAN 20 FEET FROM THE
OPENING ALONG A PATHWAY WITH A SOLID FLOOR NOT LESS THAN 24" WIDE. PROVIDE A
30x30 INCH WORKING PLATFORM IN FRONT OF THE APPLIANCE AND PROVIDE A 120-VOLT
OUTLET WITH A LIGHT FIXTURE NEAR THE APPLIANCE WITH THE LIGHT SWITCH LOCATED
AT THE ENTRANCE TO THE PASSAGEWAY.
7.) DOMESTIC DISHWASHERS REQUIRE AN APPROVED DISWAHER AIR GAP FITTING ON THE
DISCHARGE SIDE OF THE DISHWASHER. LISTED AIR GAPS SHALL BE INSTALLED WITH THE
FLOOD-LEVEL (Fl) MARKING AT OR ABOVE THE FLOOD-LEVEL OF THE SINK OR
DRAINBOARD, WHICEVER IS HIGHER.
8.) INSTANTANEOUS WATER HEATERS WITH AN INPUT RATING GREATER THAN 6.8 kbtu/HR
SHALL HAVE ISOLATION VALVES ON BOTH THE COLD-WATER SUPPLY AND TE HOT WATER
PIPE LEAVING THE WATER HEATER, AND HOSE BIBBS OR OTHER FITTINS ON EACH VALVE
FOR FLUSHING THE WATER HEATER WHEN THE VALVES ARE CLOSED.
9. ) ALL WATER LINES SHALL BE COPPER
10. ) SEWER AND VENT PIPES SHALL BE ABS
11.) WATER PIPING MATERIALS WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC.
604.1 OF THE CALIFORNIA PLUMBING CODE. PEX, CPVC AND OTHER PLASTIC WATER PIPING
SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SEC. 604 OF
THE CPS, INSTALLATION STANDARDS OF APPENDIX I OF THE CPC AND MANUFACTURERS
RECOMMENDED INSTALLATION STANDARDS. CPVC WATER PIPING REQUIRES A
CERTIFICATION OF COMPLIANCE AS SPECIFIED IN SEC 604.1.1(d) OF THE CPC PRIOR TO
PERMIT ISSUANCE.
12.) ALL HOSE BIBS MUST HAVE AN APPROVED ANTI-SIPHON DEVICE.
13.) MECHANICAL EQUIPMENT LOCATED IN A GARAGE SHALL BE GUARDED AGAINST
DAMAGE BY BEING INSTALLED BEHIND PROTECTIVE BARRIERS OR BY BEING ELEVATED OR
LOCATED OUT OF THE NORMAL PATH OF VEHICLES.
14.) SHOWER COMPARTMENTS SHALL BE NO LESS THAN 1,024 SQUARE INCHES AND ALSO
BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE.
15.) SHOWER AND TUB-SHOWER COMBINATIONS SHALL PROVIDE WITH INDIVIDUAL
CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, OR COMBINATION
PRESSURE BALANCE/THERMOSTATIC MISSING VALVE TYPE THAT PROVIDE SCALD AND
THERMAL SHOCK PROTECTION. THESE VALVES SHALL CONFORM TO ASSE 1016 OR AMSE
A112.18.1/CSA B125.1. HANDLE POSITION STOPS SHALL BE PROVIDED ON SUCH VALVES
AND SHALL BE ADJUSTED PER THE MANUFACTURER'S INSTRUCTIONS TO DELIVER A
MAXIMUM MIXED WATER SETTING OF 120 DEGREES FAHRENHEIT. WATER HEATING
THERMOSTATS SHALL NOT BE CONSIDER A SUITABLE CONTROL FOR MEETING THIS
PROVISION.
16). INSULATION OF DOMESTIC HOT WATER PIPING SHALL BE IN ACCORDANCE WITH CPC
SECTION 609.11.1 AND SECTION 609.11.2
17). BATHROOM - A SHOWER SHALL BE PROVIDED WITH MIXING VALVE THAT WILL PROVIDE
SCALD AND THERMAL SHOCK PROTECTION PROTECTION IN ACCORDANCE WITH ASSE 1016
OR ASME A112.18.1/CSA B125.1. (CPC 408.3). B. SHOWER WALL COVERINGS SHALL BE
NONABSORBENT SUCH AS CEMENT PLASTER, TILE OR APPROVED EQUAL TO 72" ABOVE
FLOOR AT SHOWER OR TUBS WITH SHOWERS. (R307.2). I. CEMENT, FIBER-CEMENT, FIBER-
MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR FIBER-REINFORCED GYPSUM
BACKERS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND
WALL AND CEILING PANELS IN SHOWER AREAS. (R702.4.2). C. WATER CLOSET SHALL HAVE
15” TO ANY WALL OR OBSTRUCTION ON EACH SIDE OF ITS CENTERLINE AND 24” CLEAR
SPACE IN FRONT. DIMENSION ON THE PLANS. (407.5 CPC).
(N) PLUMBING PLAN
SCALE: 1/8" = 1'-0"
PLUMBING PLAN &
NOTES
(E) WATER METER
1/8" = 1'-0"
(E) 4" SEWER LINE
G.C. TO VERIFY AND LOCATED
EXISTING SEWER LINE BEFORE
CONSTRUCTION.
(N) ABS 4" SEWER LINE TO CONNECT TO
EXISTING SEWER LINE.
G.C. TO VERIFY AND LOCATED EXISTING
SEWER LINE BEFORE CONSTRUCTION.
(N) APPROX.
P.O.C.
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
Juan
Orellana
(N) ADU TANKLESS
WATER HEATER
(E) GAS METER
(N) 7' GAS LINE
(N) 1/2" HOT WATER LINE
(N) 1/2" COLD
WATER LINE
(E) MAIN
WATER VALVE
PB2
SHEET:
SCALE:
DATE:
11/25/2024
Revision Table
Number
Date
Revised By
Description
1
10/27/2023
JO
PLANNING
2
01/31/2024
JO
PLANNING
3
03/08/2024
JO
BP
4
04/02/2024
JO
PCC
5
11/25/2024
JO
PCC
COMPA'S DESIGN SERVICES
949 N. IROQUOIS AVE.
ANAHEIM, CA 92801
JUAN ORELLANA _____________
PROJECT NAME: MANUEL & MARIA CASAS
MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
SANTA ANA, CA 92705
ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
SANTA ANA, CA 92705
KITCHEN SINK
1.5
CLOTH WASHER
4.0
LAVATORY
1
SHOWER
2.0
WATER CLOSET
2.5
KITCHEN SINK
1.5
SHOWER
2.0
WATER CLOSET
2.5
LAVATORY
1
LAVATORY
1
WATER CLOSET
2.5
BATHTUB
4
HOSE BIB
2.5
CLOTH WASHER
4.0
PLUMBING NOTES
Juan Orellana
CERTIFICATE OF COMPLIANCE
PAYMENT OF SCHOOL FACILITY FEES
ORANGE UNIFIED SCHOOL DISTRICT
1401 N. Handy St., Orange, CA 92867
Phone: (714) 628-5371
Developer/Applicant: MARIA CASAS
1109 N WRIGHT
SANTA ANA, CA 92701
Property Owner:
Address:
CITY OF SANTA ANA
Planning and Building Agency
Approved
FOR PERMIT ISSUANC
r
Master ID:
Date:
Phone: 1951) 809-3988
Phone:
PROJECT
Address / Location: 2617 N DEODAR ST, STE #2, SANTA ANA, CA 92705
Tentative Tract #: ® Single Family
No. of Dwelling Units: ❑ Multi Family /Condos / Apt
RESIDENTIAL
Total Square Footage: 387 SF Applicable Fee Level: ® 1 ❑ 2
Multiplied by Applicable Fee: $4.57 Total School Facility Fees: $ 0
COMMERCIAL
Total Square Footage: SF
Multiplied by Applicable Fee: $
Total School Facility Fees: $
FEES WAIVED
❑ NO
YES
Reason:
Note: Garage conversion to ADU under 500 sf
I certify that the above representations are true and correct. Developer/Applicant agrees that if it is later
determined that such representations are not true, then this Certificate of Compliance shall automatically
terminate, and the appropriate City/County shall be noti
fied.
Developer / Applicant Signature: L,fsu� C •
This certifies that the above -named Developer/Applicant has paid school facility fees in compliance with
Education Code Section 17620 et. seq. and Government Code Section 65995 et. Seq
Date: 5/5/25
By: Angelique Macis Title: Lead Accounting Tech
NOTICE: The 90-day period in which u may protest the fee described herein will begin on the date this fee is pad. However, if the fee
was imposed by the City or County o condition of approval for your project, and you have received the requisite notice. the 90-day
protest period began at the time your project was approved by the City or County.
Certificate of Compliance
Rev. 04/15/23
CERTIFICATE OF COMPLIANCE
PAYMENT OF SCHOOL FACILITY FEES
ORANGE UNIFIED SCHOOL DISTRICT
1401 N. Handy St., Orange, CA 92867
Phone: (714) 628-5371
Developer/Applicant: MARIA CASAS
1 109 N WRIGHT
SANTA ANA, CA 92701
Property Owner:
Address:
CITY OF SANTA ANA
Planning and Building Agency
may, lS.
Approved
FOR PERMIT ISSUANCE
Master ID:
Date:
Phon
Phone:
PROJECT
Address / Location: 2617 N DEODAR ST, STE #2, SANTA ANA, CA 92705
Tentative Tract #: Z Single Family
No. of Dwelling Units: ❑ Multi Family /Condos / Apt
RESIDENTIAL
Total Square Footage: 387 SF Applicable Fee Level: ❑x 1 ❑ 2
Multiplied by Applicable Fee: $4.57 Total School Facility Fees: $ 0
COMMERCIAL
Total Square Footage: SF
Multiplied by Applicable Fee: $
Total School Facility Fees: $
FEES WAIVED
❑ NO
FV1 YES
Reason:
Note: Garage conversion to ADU under 500 sf
I certify that the above representations are true and correct. Developer/Applicant agrees that if it is later
determined that such representations are not true, then this Certificate of Compliance shall automatically
terminate, and the appropriate City/County shall be notified.
Developer / Applicant Signature:
This certifies that the above -named Developer/Applicant has paid school facility fees in compliance with
Education Code Section 17620 et. seq. and Government Code Section 65995 et. Seq
Date: 5/5/25
By: Angelique Macis Title: Lead Accounting Tech
NOTICE: The 90-day period in whichyziru may protest the fee described herein will begin on the date this fee is paid. However, if the fee
was imposed by the City or County as a condition of approval for your project, and you have received the requisite notice, the 90-day
protest period began at the time your project was approved by the City or County.
Certificate of Compliance
Rev. 04/ 15/23
Dong Engineering, Inc.
7661 GARDEN GROVE BLVD. , GARDEN GROVE, CA 92841
Office: (714) 617-5979
Email: info@dongengineering.com
DATE:2/16/2025
CLIENT:
JOB NO.:240140
Project:
GARAGE CONVERT TO ADU
STRUCTURAL CALCULATIONS FOR THE BUILDING AT:
2617 DEODAR ST,
SANTA ANA, CA 92705
1 of 14
Dong Engineering Inc.
GARAGE CONVERT TO ADU Job#:240140
2617 DEODAR ST, SANTA ANA, CA 92705 Date:
ROOF:SHINGLE
Slope 4:12
Live Load 20 psf
Roof'g Material 3.0 psf
Sheathing 2.0 psf
Trusses / Rafters 2.0 psf
Ceiling Joists 2.0 psf
Drywall 2.0 psf
Sprinkler 0.5 psf
Solar 3.0 psf
Miscellaneous 0.5 psf
Total D.L.15 psf
Total Load 35 psf
EXTERIOR WALL:INTERIOR WALL:
EXTERIOR:9 DRYWALL:3
DRYWALL:3.0 DRYWALL:3.0
STUDS:2.0 STUDS:2.0
MISC.:1.0 MISC.:2.0
DL=15.0 PSF DL=10.0 PSF
REVISIONS:
1 Sheets:Date:
Init:Remark:
2 Sheets:Date:
Init:Remark:
3 Sheets:Date:
Init:Remark:
4 Sheets:Date:
Init:Remark:
5 Sheets:Date:
Init:Remark:
6 Sheets:Date:
Init:Remark:
LOADING CONDITIONS
2/16/2025
2 of 14
Dong Engineering Inc.
GARAGE CONVERT TO ADU
2617 DEODAR ST, SANTA ANA, CA 92705
Job#: 240140
Date: 2/16/2025
PLAN: 1
CODE: CBC 2022
A. General:
Number of stories 1
Building risk category II
Design Code CBC 2022
Load standard ASCE 7-16 ASCE 7-16
Design Load Combination ASD
B. Lateral Loads Data:
WIND STANDARD ASCE 7-16(Directional Procedure)
Wind Exposure C
Wind Speed 110
Enclosure Enclosed Building
Velocity pressure qz = 0.00256KzKztKdKeV2 (26.10-1)
Velocity pressure exposure coefficient Kz (Table 26.10-1)
Directionality Factor Kd (Table 26.6-1)
Topographic factor defined Kzt (26.8.2)
Gust Effect Factor G (26.11.1)
Pressures for MWFRS p = qGCp – qi(GCpi)(27.3-1)
External pressure coefficient Cp (Fig. 27.3-1)
Internal pressure coefficient Gcpi (Table 26.13-1)
SEISMIC STANDARD ASCE 7-16(Equivalent Lateral Force Procedure)
Seismic Design Category (Table 11.6-1)
Importance factor I (Table 1.5-2)
Soil Site Class D-Default (Table 20-3-1)
Response modification coefficient R = 6.5 (Table 12.2-1)
System overstrength coefficient Ω = 2.5 (Table 12.2-1)
Approximate fundamental period parameters Ct = 0.02 x = 0.75 (Table 12.8-2)
Building Height (ft)13.5
Building period T=Ta (sec) = 0.25 (Formula 12.8-7)
Base Shear Adjustment Factor = 1
Seismic response coefficient Cs = 0.16 (Formula 12.8-2)
BUILDING INFORMATION
3 of 14
USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error.
USGS web services are now operational so this tool should work as expected.
2617 Deodar St, Santa Ana, CA 92705, USA
Latitude, Longitude: 33.7725519, -117.8316302
Date 2/16/2025, 6:37:13 PM
Design Code Reference Document ASCE7-16
Risk Category II
Site Class D - Default (See Section 11.4.3)
Type Value Description
SS 1.337 MCER ground motion. (for 0.2 second period)
S1 0.476 MCER ground motion. (for 1.0s period)
SMS 1.604 Site-modified spectral acceleration value
SM1 null -See Section 11.4.8 Site-modified spectral acceleration value
SDS 1.069 Numeric seismic design value at 0.2 second SA
SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA
Type Value Description
SDC null -See Section 11.4.8 Seismic design category
Fa 1.2 Site amplification factor at 0.2 second
Fv null -See Section 11.4.8 Site amplification factor at 1.0 second
PGA 0.558 MCEG peak ground acceleration
FPGA 1.2 Site amplification factor at PGA
PGAM 0.67 Site modified peak ground acceleration
TL 8 Long-period transition period in seconds
SsRT 1.337 Probabilistic risk-targeted ground motion. (0.2 second)
SsUH 1.433 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration
SsD 1.5 Factored deterministic acceleration value. (0.2 second)
S1RT 0.476 Probabilistic risk-targeted ground motion. (1.0 second)
S1UH 0.514 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration.
S1D 0.6 Factored deterministic acceleration value. (1.0 second)
PGAd 0.569 Factored deterministic acceleration value. (Peak Ground Acceleration)
PGAUH 0.558 Uniform-hazard (2% probability of exceedance in 50 years) Peak Ground Acceleration
CRS 0.933 Mapped value of the risk coefficient at short periods
CR1 0.927 Mapped value of the risk coefficient at a period of 1 s
CV 1.367 Vertical coefficient
2/16/25, 6:37 PM U.S. Seismic Design Maps
https://www.seismicmaps.org 1/2
4 of 14
DISCLAIMER
While the information presented on this website is believed to be correct, SEAOC /OSHPD and its sponsors and contributors assume no responsibility or liability for its
accuracy. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its
accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC / OSHPD do not intend that the use of this information replace the sound judgment of
such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and
applying the results of the seismic data provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this
website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude
location in the search results of this website.
2/16/25, 6:37 PM U.S. Seismic Design Maps
https://www.seismicmaps.org 2/2
5 of 14
1Y
1X
ROOF SHEARWALL LAYOUT
A
B
6 of 14
Dong Engineering Inc.
GARAGE CONVERT TO ADU
2617 DEODAR ST, SANTA ANA, CA 92705
Job#: 240140
Date: 2/16/2025
PLAN: 1
CODE: CBC 2022
SECTION: 1X
Number of Story: 1 Section width: 18.5(ft)Section length: 21.5(ft)
Base height: 0(ft)Slope roof height: 13(ft)Gable mean roof height: 11.5(ft)
WIND PARAMETERS PER ASCE7-16, CHAPTER 27, MWFRS BUILDINGS OF ALL HEIGHTS:
Wind speed = 110, Wind exposure = C, Wind importance factor Iw = 1
Coefficients: Kd = 0.85, Kzt = 1, G = 0.85, Gcpi = +/-0.18, omega = 1
B = 52.5(ft), L = 47.5(ft), H = 13.5(ft)-->L/B = 0.9, H/L = 0.28
Wall coefficient: Cpw = 0.8, Cpl = -0.5
Wind exposure = C-->anpha = 9.5, zg = 900
Kz = 2.01*(15/zg)^(2/anpha)qz = 0.00256*Kz*Kzt*Kd*V^2*Iw P = G(Cpw*qz+Cpl*qh)
WIND LOAD:
SEISMIC PARAMETERS PER ASCE7-16, CHAPTER 12.8, ELF PROCEDURE:
Light frame wood-->Rx = 6.5, Site class :D, SDS = 2FaSs/3 =1.069, SD1 = 2FvS1/3 =0,
Seismic design category: D, I = 1, 0.7*V = 0.7*SDS*I*W/Rx = 0.7*1.069*1*W/6.5 = 0.1151*W
Total Seismic Load = 55.26 = 55.26 PLF
Redistrib: 480*9 = 4320 PLFxFT
DIAPHRAGM & CHORD FORCE PER ASCE07-16 SECTION 12.10
ROOF DIAPHRAGM
Max shear = 78.94 x 18.5 / (2 x 21.5) = 33.96 PLF
Use: 15/32" apa rated unblock 32/16 w/8d common nails at 6", 6", 12" o.c.
Chord force = 78.94 x 18.5^2 / (8 x 21.5) = 157.08 LBS
Splice w/ min. (1) 16d sinker nails each side of splice at 8" o.c. (standard construction)
(z, Kz, qz, P): (15, 0.85, 22.35, 24.7); (15, 0.85, 22.35, 15.2)
ROOF
Roof = 15*21.5 = 322.5 PLF
Wall = 15*1*4.5 + 10*2*4.5 = 157.5 PLF
Shear = 0.1151(322.5+157.5) = 0.1151*480 = 55.25 PLF
Plate height: ROOF = 9(ft)
SHEAR ROOF = 55.26*480*9/4320 = 55.26 PLF
SHEAR ROOF = 0.6*W = 78.08(plf)
ROOF 78.08 PLF WIND GOVERN
7 of 14
Dong Engineering Inc.
GARAGE CONVERT TO ADU
2617 DEODAR ST, SANTA ANA, CA 92705
Job#: 240140
Date: 2/16/2025
PLAN: 1
CODE: CBC 2022
SECTION: 1Y
Number of Story: 1 Section width: 21.5(ft)Section length: 18.5(ft)
Base height: 0(ft)Slope roof height: 13(ft)Gable mean roof height: 11.5(ft)
WIND PARAMETERS PER ASCE7-16, CHAPTER 27, MWFRS BUILDINGS OF ALL HEIGHTS:
Wind speed = 110, Wind exposure = C, Wind importance factor Iw = 1
Coefficients: Kd = 0.85, Kzt = 1, G = 0.85, Gcpi = +/-0.18, omega = 1
B = 47.5(ft), L = 52.5(ft), H = 13.5(ft)-->L/B = 1.11, H/L = 0.26
Wall coefficient: Cpw = 0.8, Cpl = -0.48, Roof coefficient: Cpw = (0.13;-0.37), Cpl = -0.57
Wind exposure = C-->anpha = 9.5, zg = 900
Kz = 2.01*(15/zg)^(2/anpha)qz = 0.00256*Kz*Kzt*Kd*V^2*Iw P = G(Cpw*qz+Cpl*qh)
WIND LOAD:
SEISMIC PARAMETERS PER ASCE7-16, CHAPTER 12.8, ELF PROCEDURE:
Light frame wood-->Ry = 6.5, Site class :D, SDS = 2FaSs/3 =1.069, SD1 = 2FvS1/3 =0,
Seismic design category: D, I = 1, 0.7*V = 0.7*SDS*I*W/Ry = 0.7*1.069*1*W/6.5 = 0.1151*W
Total Seismic Load = 52.67 = 52.67 PLF
Redistrib: 457.5*9 = 4117.5 PLFxFT
DIAPHRAGM & CHORD FORCE PER ASCE07-16 SECTION 12.10
ROOF DIAPHRAGM
Max shear = 75.24 x 21.5 / (2 x 18.5) = 43.72 PLF
Use: 15/32" apa rated unblock 32/16 w/8d common nails at 6", 6", 12" o.c.
Chord force = 75.24 x 21.5^2 / (8 x 18.5) = 235 LBS
Splice w/ min. (2) 16d sinker nails each side of splice at 8" o.c. (standard construction)
(z, Kz, qz, P): (15, 0.85, 22.35, 24.3)
ROOF
Roof = 15*18.5 = 277.5 PLF
Wall = 15*2*4.5 + 10*1*4.5 = 180 PLF
Shear = 0.1151(277.5+180) = 0.1151*457.5 = 52.66 PLF
Plate height: ROOF = 9(ft)
SHEAR ROOF = 52.67*457.5*9/4117.5 = 52.67 PLF
SHEAR ROOF = 0.6*W = 97.55(plf)
ROOF 97.55 PLF WIND GOVERN
8 of 14
Do
ng
E
n
g
i
n
e
e
r
i
n
g
I
n
c
.
GA
R
A
G
E
C
O
N
V
E
R
T
T
O
A
D
U
26
1
7
D
E
O
D
A
R
S
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
5
Jo
b
#
:
2
4
0
1
4
0
Da
t
e
:
2
/
1
6
/
2
0
2
5
PL
A
N
:
1
CO
D
E
:
C
B
C
2
0
2
2
W
a
l
l
Se
c
.
St
o
.
W
i
n
d
Se
i
s
m
i
c
Sp
a
n
Of
f
s
e
t
W
i
n
d
Se
i
s
m
i
c
(#
)
(#
)
(#
)
v_
(
p
l
f
)
v_
(
p
l
f
)
(f
t
)
(f
t
)
V_
(
l
b
)
V_
(
l
b
)
A
Ty
p
e
A
:
W
i
n
d
=
7
2
3
(
l
b
)
,
S
e
i
s
m
i
c
=
6
6
5
(
l
b
)
A
1X
1
78
.
1
55
.
3
18
.
5
72
2
51
1
l-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
8
.
5
(
f
t
)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
l
B
Ty
p
e
A
:
W
i
n
d
=
7
2
3
(
l
b
)
,
S
e
i
s
m
i
c
=
6
6
5
(
l
b
)
B
1X
1
78
.
1
55
.
3
18
.
5
72
2
51
1
l-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
8
.
5
(
f
t
)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
l
#N
/
A
#N
/
A
#N
/
A
#N
/
A
#N
/
A
#N
/
A
De
s
c
r
i
p
t
i
o
n
V_
(
l
b
)
=
v
_
(
p
l
f
)
*
S
p
a
n
*
S
p
a
n
/
2
/
(
S
p
a
n
+
O
f
f
s
e
t
)
LA
T
E
R
A
L
p
F
a
c
t
o
r
:
X
D
i
r
e
c
t
i
o
n
:
p
=
1
.
3
;
Y
D
i
r
e
c
t
i
o
n
:
p
=
0
9 of 14
Do
ng
E
n
g
i
n
e
e
r
i
n
g
I
n
c
.
GA
R
A
G
E
C
O
N
V
E
R
T
T
O
A
D
U
26
1
7
D
E
O
D
A
R
S
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
5
Jo
b
#
:
2
4
0
1
4
0
Da
t
e
:
2
/
1
6
/
2
0
2
5
PL
A
N
:
1
CO
D
E
:
C
B
C
2
0
2
2
Ma
x
p
a
n
e
l
d
e
f
l
e
c
t
i
o
n
:
=
0
.
0
5
"
|
4
*
d
*
1
.
4
=
0
.
2
8
"
<
0
.
0
2
x
1
0
8
=
2
.
1
6
"
4.
7
5
6.
2
5
4.
0
0
OV
E
R
T
U
R
N
A
N
A
L
Y
S
I
S
Le
f
t
S
i
d
e
Ho
l
d
D
o
w
n
HD
U
2
Po
s
t
S
i
z
e
4x
4
Up
l
i
f
t
(
k
i
p
s
)
0.
6
Co
m
.
(
k
i
p
s
)
1.
0
Ri
g
h
t
S
i
d
e
Ho
l
d
D
o
w
n
HD
U
2
Po
s
t
S
i
z
e
4x
4
Te
n
s
i
o
n
(
k
i
p
s
)
0.
6
Co
m
.
(
k
i
p
s
)
1.
0
An
c
h
o
r
B
o
l
t
5/
8
"
x
1
2
"
[2
]
sp
a
c
e
d
e
q
u
a
l
l
y
2.
7
5
Dr
a
g
F
o
r
c
e
:
A:
S
i
m
p
s
o
n
M
S
T
A
3
0
(
1
8
8
0
L
B
)
-
A
l
t
o
n
e
r
o
w
(
9
)
#
1
6
e
a
.
s
i
d
e
o
f
s
p
l
i
c
e
Fr
a
m
i
n
g
C
l
i
p
s
S
p
a
c
i
n
g
S
e
e
S
h
e
a
r
W
a
l
l
S
c
h
e
d
u
l
e
9.00 ft
LI
N
E
A
(
D
i
r
e
c
t
i
o
n
:
X
)
@
F
I
R
S
T
F
L
O
O
R
|
W
i
n
d
:
7
2
3
l
b
s
|
S
e
i
s
m
i
c
:
6
6
5
l
b
s
|
S
h
e
a
r
P
a
n
e
l
T
y
p
e
:
A
|
(
þ
=
1
.
3
)
To
t
a
l
L
e
n
g
t
h
=
2
1
f
t
|
T
o
t
a
l
S
h
e
a
r
W
a
l
l
L
e
n
g
t
h
=
6
.
2
5
f
t
|
S
h
e
a
r
D
i
a
p
h
r
a
g
m
=
3
5
p
l
f
|
D
e
s
i
g
n
S
h
e
a
r
W
a
l
l
=
1
1
6
p
l
f
(
W
i
n
d
)
/
1
0
6
p
l
f
(
S
e
i
s
m
i
c
)
Se
i
s
m
i
c
L
o
a
d
C
o
m
b
i
n
a
t
i
o
n
:
(
1
.
0
+
0
.
1
4
S
DS
)D
+
H
+
F
+
0
.
7
Q
E (
C
o
m
p
r
e
s
s
i
o
n
)
|
L
o
a
d
C
o
m
b
i
n
a
t
i
o
n
U
s
e
:
(
0
.
6
-
0
.
1
4
S
DS
)D
+
H
+
0
.
7
Q
E (
T
e
n
s
i
o
n
)
W
i
n
d
L
o
a
d
C
o
m
b
i
n
a
t
i
o
n
:
D
+
0
.
7
5
L
+
0
.
7
5
(
0
.
6
W
)
(
C
o
m
p
r
e
s
s
i
o
n
)
|
L
o
a
d
C
o
m
b
i
n
a
t
i
o
n
U
s
e
:
0
.
6
D
+
H
+
0
.
6
W
(
T
e
n
s
i
o
n
)
Se
i
s
m
i
c
C
a
p
a
c
i
t
y
:
P
1
(
1
.
4
/
1
.
4
)
=
1
.
4
k
i
p
s
(
S
e
c
.
4
.
3
.
4
.
1
)
W
i
n
d
C
a
p
a
c
i
t
y
:
P
1
(
1
.
9
/
1
.
9
)
=
1
.
9
k
i
p
s
(
S
e
c
.
4
.
3
.
4
.
1
)
In
d
i
v
i
d
u
a
l
f
u
l
l
-
h
e
i
g
h
t
w
a
l
l
s
e
g
m
e
n
t
s
h
e
a
r
w
a
l
l
(
S
e
c
.
4
.
3
.
2
.
1
)
3.
2
5
P1
27
8
-23
5
d
=
8𝑣
ℎ3
𝐸
�
�
�
�
+
𝑣ℎ
10
0
0
�
�
𝑎
+
ℎ𝑏
∆𝑎
10 of 14
Do
ng
E
n
g
i
n
e
e
r
i
n
g
I
n
c
.
GA
R
A
G
E
C
O
N
V
E
R
T
T
O
A
D
U
26
1
7
D
E
O
D
A
R
S
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
5
Jo
b
#
:
2
4
0
1
4
0
Da
t
e
:
2
/
1
6
/
2
0
2
5
PL
A
N
:
1
CO
D
E
:
C
B
C
2
0
2
2
Ma
x
p
a
n
e
l
d
e
f
l
e
c
t
i
o
n
:
=
0
.
0
1
"
|
4
*
d
*
1
.
4
=
0
.
0
6
"
<
0
.
0
2
x
1
0
8
=
2
.
1
6
"
3.
2
5
8.
0
0
1.
0
0
5.
0
0
1.
7
5
OV
E
R
T
U
R
N
A
N
A
L
Y
S
I
S
Le
f
t
S
i
d
e
Ho
l
d
D
o
w
n
No
U
p
l
i
f
t
Po
s
t
S
i
z
e
Up
l
i
f
t
(
k
i
p
s
)
Co
m
.
(
k
i
p
s
)
Ri
g
h
t
S
i
d
e
Ho
l
d
D
o
w
n
No
U
p
l
i
f
t
Po
s
t
S
i
z
e
Te
n
s
i
o
n
(
k
i
p
s
)
Co
m
.
(
k
i
p
s
)
An
c
h
o
r
B
o
l
t
5/
8
"
x
1
2
"
[2
]
sp
a
c
e
d
e
q
u
a
l
l
y
6.
2
5
2.
2
5
P1
3.
2
5
Dr
a
g
F
o
r
c
e
:
A:
S
i
m
p
s
o
n
M
S
T
A
3
0
(
1
8
8
0
L
B
)
-
A
l
t
o
n
e
r
o
w
(
9
)
#
1
6
e
a
.
s
i
d
e
o
f
s
p
l
i
c
e
Fr
a
m
i
n
g
C
l
i
p
s
S
p
a
c
i
n
g
S
e
e
S
h
e
a
r
W
a
l
l
S
c
h
e
d
u
l
e
9.00 ft
LI
N
E
B
(
D
i
r
e
c
t
i
o
n
:
X
)
@
F
I
R
S
T
F
L
O
O
R
|
W
i
n
d
:
7
2
3
l
b
s
|
S
e
i
s
m
i
c
:
6
6
5
l
b
s
|
S
h
e
a
r
P
a
n
e
l
T
y
p
e
:
A
|
(
þ
=
1
.
3
)
To
t
a
l
L
e
n
g
t
h
=
3
0
.
7
5
f
t
|
T
o
t
a
l
S
h
e
a
r
W
a
l
l
L
e
n
g
t
h
=
8
f
t
|
S
h
e
a
r
D
i
a
p
h
r
a
g
m
=
2
4
p
l
f
|
D
e
s
i
g
n
S
h
e
a
r
W
a
l
l
=
9
0
p
l
f
(
W
i
n
d
)
/
8
3
p
l
f
(
S
e
i
s
m
i
c
)
Se
i
s
m
i
c
L
o
a
d
C
o
m
b
i
n
a
t
i
o
n
:
(
1
.
0
+
0
.
1
4
S
DS
)D
+
H
+
F
+
0
.
7
Q
E (
C
o
m
p
r
e
s
s
i
o
n
)
|
L
o
a
d
C
o
m
b
i
n
a
t
i
o
n
U
s
e
:
(
0
.
6
-
0
.
1
4
S
DS
)D
+
H
+
0
.
7
Q
E (
T
e
n
s
i
o
n
)
W
i
n
d
L
o
a
d
C
o
m
b
i
n
a
t
i
o
n
:
D
+
0
.
7
5
L
+
0
.
7
5
(
0
.
6
W
)
(
C
o
m
p
r
e
s
s
i
o
n
)
|
L
o
a
d
C
o
m
b
i
n
a
t
i
o
n
U
s
e
:
0
.
6
D
+
H
+
0
.
6
W
(
T
e
n
s
i
o
n
)
Se
i
s
m
i
c
C
a
p
a
c
i
t
y
:
P
1
(
1
.
8
/
1
.
8
)
=
1
.
8
k
i
p
s
(
S
e
c
.
4
.
3
.
4
.
1
)
W
i
n
d
C
a
p
a
c
i
t
y
:
P
1
(
2
.
5
/
2
.
5
)
=
2
.
5
k
i
p
s
(
S
e
c
.
4
.
3
.
4
.
1
)
In
d
i
v
i
d
u
a
l
f
u
l
l
-
h
e
i
g
h
t
w
a
l
l
s
e
g
m
e
n
t
s
h
e
a
r
w
a
l
l
(
S
e
c
.
4
.
3
.
2
.
1
)
77
-46
3
d
=
8𝑣
ℎ3
𝐸
�
�
�
�
+
𝑣ℎ
10
0
0
�
�
𝑎
+
ℎ𝑏
∆𝑎
11 of 14
Dong Engineering Inc.
GARAGE CONVERT TO ADU
2617 DEODAR ST, SANTA ANA, CA 92705
Job#: 240140
Date: 2/16/2025
PLAN: 1
CODE: CBC 2022
Shear Wall (X-X Direction)
Line Story Section Span Wind Seismic Added V (lb)H L v Type
###(ft)(plf)(plf)Wind Seismic (ft)(ft)(plf)
A 1 1X 18.5 78 55 9 6.25 116 A
B 1 1X 18.5 78 55 9 8 90 A
v(plf) = V/L
Shear wall design concept is chosen as Individual full-height wall segment (Sec. 4.3.2.1 ) and Force-Transfer Around
Openings (FTAO) (Sec. 4.3.2.2 ).
For mix-type, chosen concept is determined by more critical design result.
V2 = Seismic*Span/2 + Added Vseismic
Line shear V = Maximum(V1;V2)
V1 = Wind*Span/2 + Added Vwind
SUMMARY SHEAR WALL
12 of 14
Dong Engineering Inc.
GARAGE CONVERT TO ADU
2617 DEODAR ST, SANTA ANA, CA 92705
Job #: 240140
Date : 02/16/2025
Plan : 1
BEAM : C1 - C.J. 2X8 DFL#2 @ 16" O.C. TYP. (MAX L=
20'-3")
Loads(Downward+)
Ceiling Joist: (4+10)(1.3) = (DL=5.3PLF; LLr=13.4PLF) form 0 to 20.25
Reactions (D+Lr+L/Max. Load comb.)
Bearing Down Up
1 189/189 0
2 189/189 0
USE 2 x 8
Critcal Shear = 189 LB @0' 1.5xV/(F'v x A)= 0.11
F'v = 225, A = 10.88
Critcal Moment = 958 LB-FT @10.12' M/(F'b x S)= 0.56
F'b = 1552, S = 13.14
Critical Deflection for TL = -0.928 INCH @ 10.12 L/240 = 1.012"
Critical Deflection for LL = -0.663 INCH @ 10.12 L/360 = 0.675"
1 2
Moment
Shear
Deflection
20.25'
13 of 14
Dong Engineering Inc.
GARAGE CONVERT TO ADU
2617 DEODAR ST, SANTA ANA, CA 92705
Job#: 240140
Date: 2/16/2025
PLAN: 1
CODE: CBC 2022
1500 psf
Trib Trib Wall Height
DL(psf)LL(psf)roof(ft)DL(psf)LL(psf)floor(ft)DL(psf)wall(ft)
15 20 4 15 9
Roof:(DL+LL)(Trib) =140 plf
Floor:(DL+LL)(Trib) =0 plf
Wall:DL (Height)=135 plf
275 plf
275 /(12"/12)=275 psf< 1500 psf
P(allowable)
P(allowable) = 4,500 #
18 in
FOUNDATION - 1-STORY
Allowable soil bearing value:
Roof Floor
use 12" wide cont. ftg w/ 2-#4 top & bott.
45𝑜
14 of 14
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 1 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
GENERAL INFORMATION
01 Project Name 240140
02 Run Title Title 24 Analysis
03 Project Location 2617 DEODAR ST,
04 City SANTA ANA 05 Standards Version 2022
06 Zip code 92705 07 Software Version EnergyPro 9.2
08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)250
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope Addition and/or Alteration 13 Number of Bedrooms 5
14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft2)1760 17 Fenestration Average U-factor 0.3
18 Total Cond. Floor Area (ft2)1760 19 Glazing Percentage (%)11.02%
20 ADU Bedroom Count 1 21 ADU Conditioned Floor Area 387
22 Fuel Type Natural gas 23 No Dwelling Unit:No
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 Building does not incorporate Special Features
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 2 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0 30.67 0 30.61 0 0.06
Space Cooling 0 105.53 0 108.66 0 -3.13
IAQ Ventilation 0 0 0 0 0 0
Water Heating 0 39.9 0 36.18 0 3.72
Self
Utilization/Flexibility
Credit
Efficiency Compliance
Total 0 176.1 0 175.45 0 0.65
Photovoltaics 0 0
Battery 0
Flexibility
Indoor Lighting 0 6.8 0 6.8
Appl. & Cooking 0 15.72 0 15.72
Plug Loads 0 42.46 0 42.46
Outdoor Lighting 0 1.65 0 1.65
TOTAL COMPLIANCE 0 242.73 0 242.08
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 3 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
ENERGY USE INTENSITY
Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage
Gross EUI1 35.76 34.92 0.84 2.35
Net EUI2 35.76 34.92 0.84 2.35
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•NO SPECIAL FEATURES REQUIRED
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
•Indoor air quality ventilation
•Minimum Airflow
•Refrigerant Charge verification required if a refrigerant containing component is altered
•Fan Efficacy Watts/CFM
•Verified HSPF
•Verified heat pump rated heating capacity
•Duct leakage testing
•Duct Sealing required if a duct system component, plenum, or air handling unit is altered
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)Number of Dwelling
Units Number of Bedrooms Number of Zones Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
240140 1760 1 5 2 0 1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 4 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status
ADU Conditioned (N) HVAC1 387 9 DHW Sys 1 Existing Unchanged
(E) House Conditioned (E) HVAC2 1373 9 DHW Sys 1 Existing Unchanged
OPAQUE SURFACES
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and
Door Area (ft2)Tilt (deg)Wall Exceptions Status Verified Existing
Condition
Front wall ADU R-15 Wall 250 Front 146 32 90 none Altered No
Left wall ADU R-15 Wall 340 Left 189 15 90 none Altered No
Right wall ADU R-15 Wall 160 Right 189 26 90 none Altered No
Front wall 2 (E) House R-0 Wall 250 Front 306 32 90 none Existing No
Left wall 2 (E) House R-0 Wall 340 Left 234 0 90 none Existing No
Rear wall (E) House R-0 Wall 70 Back 469 122 90 none Existing No
Right wall 2 (E) House R-0 Wall 160 Right 234 27 90 none Existing No
Interior front
wall to AD (E) House>>ADU R-0 Wall1 n/a n/a 146 0 n/a Existing No
Roof ADU R-30 Roof Attic n/a n/a 387 n/a n/a Altered No
Roof 2 (E) House R-0 Roof Attic n/a n/a 1373 n/a n/a Existing No
ATTIC
01 02 03 04 05 06 07 08 09 10
Name Construction Type Roof Rise
(x in 12)
Roof
Reflectance
Roof
Emittance
Radiant
Barrier Cool Roof Status Verified Existing
Condition
Attic ADU Attic RoofADU Ventilated 4 0.1 0.85 No No Existing No
Attic (E) House Attic Roof(E) House Ventilated 4 0.1 0.85 No No Existing No
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 5 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
Name Type Surface Orientatio
n Azimuth Width
(ft)
Heigh
t (ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior
Shading Status
Verified
Existing
Condition
WN 03 Window Front wall Front 250 1 16 0.3 NFRC 0.23 NFRC Bug Screen New NA
WN 03 2 Window Front wall Front 250 1 16 0.3 NFRC 0.23 NFRC Bug Screen New NA
WN 04 Window Left wall Left 340 1 9 0.3 NFRC 0.23 NFRC Bug Screen New NA
WN 02 Window Left wall Left 340 1 6 0.3 NFRC 0.23 NFRC Bug Screen New NA
WN 01 Window Right wall Right 160 1 6 0.3 NFRC 0.23 NFRC Bug Screen New NA
WE 3040 Window Front wall 2 Front 250 1 12 0.3 NFRC 0.23 NFRC Bug Screen Existing No
DE 8068 Window Rear wall Back 70 1 54 0.3 NFRC 0.23 NFRC Bug Screen Existing No
WE 7640 Window Rear wall Back 70 1 30 0.3 NFRC 0.23 NFRC Bug Screen Existing No
WE 6030 Window Rear wall Back 70 1 18 0.3 NFRC 0.23 NFRC Bug Screen Existing No
WE 3030 Window Right wall 2 Right 160 1 9 0.3 NFRC 0.23 NFRC Bug Screen Existing No
WE 6030 2 Window Right wall 2 Right 160 1 18 0.3 NFRC 0.23 NFRC Bug Screen Existing No
OPAQUE DOORS
01 02 03 04 05 06
Name Side of Building Area (ft2)U-factor Status Verified Existing Condition
DN 01 Right wall 20 0.5 New n/a
DE 3068 Front wall 2 20 0.2 Existing No
DE 3068 2 Rear wall 20 0.2 Existing No
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 6 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
SLAB FLOORS
01 02 03 04 05 06 07 08 09 10
Name Zone Area (ft2)Perimeter (ft)
Edge Insul.
R-value and
Depth
Edge Insul.
R-value and
Depth
Carpeted Fraction Heated Status Verified Existing
Condition
Slab-on-Grade ADU 387 80 none 0 80%No Altered No
Slab-on-Grade 2 (E) House 1373 157 none 0 80%No Existing No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
Exterior Finish: 3 Coat Stucco
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-0 Wall1 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.277
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Other Side Finish: Gypsum Board
Attic RoofADU Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Attic Roof(E) House Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 7 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-30 Roof Attic Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032
Over Ceiling Joists: R-20.9 insul.
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
R-0 Roof Attic Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04 05
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50
Not Required Not Required N/A n/a n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name System Type Distribution
Type
Water Heater
Name
Number of
Units
Solar Heating
System
Compact
Distribution
HERS
Verification
Water Heater
Name (#)Status
Verified
Existing
Condition
Existing Water
Heating
System
DHW Sys 1 Domestic Hot
Water (DHW)Standard DHW Heater
1 1 n/a None n/a DHW Heater
1 (1)New NA
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 8 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
Name
Heating
Element
Type
Tank Type # of
Units
Tank Vol.
(gal)
Heating
Efficiency
Type
Efficiency Rated
Input Type
Input
Rating or
Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss or
Recovery
Eff
1st Hr.
Rating or
Flow Rate
Tank Location Status
Verified
Existing
Condition
DHW
Heater 1 Gas Consumer
Instantaneous 1 0 UEF 0.93 Btu/Hr 200000 0 n/a n/a New n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution
Type Recirculation Control Shower Drain Water Heat
Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name System Type Heating Unit
Name
Heating
Equipment
Count
Cooling Unit
Name
Cooling
Equipment
Count
Fan Name Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Existing HVAC
System
(N) HVAC1
Heat pump
heating
cooling
Heat Pump
System 1 1 Heat Pump
System 1 1 HVAC Fan 1
Air
Distribution
System 1
Setback New No
(E) HVAC2
Heating and
cooling
system other
Heating
Component
2
1
Cooling
Component
2
1 HVAC Fan 2
Air
Distribution
System 2
n/a Existing No
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 9 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
HVAC - HEATING UNIT TYPES
01 02 03 04 05
Name System Type Number of Units Heating Efficiency Heating Unit Brand
Heating Component 2 Central gas furnace 1 AFUE - 78 n/a
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08 09
Name System Type Number of Units Efficiency Metric Efficiency
EER/EER2/CEER
Efficiency
SEER/SEER2 Zonally Controlled Mulit-speed
Compressor HERS Verification
Cooling
Component 2 Central split AC 1 EER/SEER 11 12 Not Zonal Single Speed
Cooling
Component
2-hers-cool
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11 12 13
Name System Type Number of
Units
Heating Cooling
Zonally
Controlled
Compressor
Type HERS VerificationHeating
Efficiency
Type
HSPF/HS
PF2/COP Cap 47 Cap 17
Cooling
Efficiency
Type
SEER/SE
ER2
EER/EER
2/CEER
Heat Pump
System 1 Central split HP 1 HSPF 10 17000 13500 EERSEER 14 12 Not Zonal Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER/EER2 Verified
SEER/SEER2
Verified Refrigerant
Charge
Verified
HSPF/HSPF2
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 350 Not Required Not Required No Yes Yes Yes
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 10 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
Name Type Design Type
Duct Ins.
R-value
Duct
Location Surface Area
Bypass Duct Duct Leakage HERS
Verification Status
Verified
Existing
Condition
Existing
Distribution
system
New Ducts
>= 25 ftSuppl
y
Retur
n
Suppl
y
Retur
n
Suppl
y
Retur
n
Air
Distribution
System 1
Unconditio
ned attic
Non-
Verified R-6 R-6 Atti
c
Atti
c n/a n/a No Bypass
Duct
Sealed and
Tested
Air
Distribution
System
1-hers-dist
New n/a No
Air
Distribution
System 2
Unconditio
ned attic
Non-
Verified R-8 R-8 Atti
c
Atti
c n/a n/a No Bypass
Duct
Existing
(not
specified)
Air
Distribution
System
2-hers-dist
Existing No No
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC Fan 2 HVAC Fan 0.45 HVAC Fan 2-hers-fan
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 11 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
HVAC Fan 2-hers-fan Not Required 0
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2024-03-31T22:35:40-07:00 (Page 12 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-31 22:36:03
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 1 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
GENERAL INFORMATION
01 Project Name 240140
02 Run Title Title 24 Analysis
03 Project Location 2617 DEODAR ST,
04 City SANTA ANA 05 Standards Version 2022
06 Zip code 92705 07 Software Version EnergyPro 9.3
08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)250
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope Addition and/or Alteration 13 Number of Bedrooms 5
14 Addition Cond. Floor Area (ft2)387 15 Number of Stories 1
16 Existing Cond. Floor Area (ft2)1373 17 Fenestration Average U-factor 0.3
18 Total Cond. Floor Area (ft2)1760 19 Glazing Percentage (%)11.02%
20 ADU Bedroom Count 1 21 ADU Conditioned Floor Area 387
22 Fuel Type Natural gas 23 No Dwelling Unit:No
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 2 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)Margin (EDR1)Margin (EDR2)
Space Heating 0 20.83 0 21.2 0 -0.37
Space Cooling 0 70.09 0 73.72 0 -3.63
IAQ Ventilation 0 0 0 0 0 0
Water Heating 0 39.9 0 32.9 0 7
Self
Utilization/Flexibility
Credit
0 0
Efficiency Compliance
Total 0 130.82 0 127.82 0 3
Photovoltaics 0 0
Battery 0
Flexibility
Indoor Lighting 0 6.8 0 6.8
Appl. & Cooking 0 17.92 0 17.92
Plug Loads 0 42.46 0 42.46
Outdoor Lighting 0 1.65 0 1.65
TOTAL COMPLIANCE 0 199.65 0 196.65
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 3 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
ENERGY USE INTENSITY
Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Margin (kBtu/ft2 - yr )Margin Percentage
Gross EUI1 29.64 27.87 1.77 5.97
Net EUI2 29.64 27.87 1.77 5.97
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Point of use
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
•Indoor air quality ventilation
•Minimum Airflow
•Refrigerant Charge verification required if a refrigerant containing component is altered
•Fan Efficacy Watts/CFM
•Verified HSPF
•Verified heat pump rated heating capacity
•Duct leakage testing
•Duct Sealing required if a duct system component, plenum, or air handling unit is altered
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)Number of Dwelling
Units Number of Bedrooms Number of Zones Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
240140 1760 1 5 2 0 1
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 4 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status
ADU Conditioned (N) HVAC1 387 9 DHW Sys 1 New
(E) House Conditioned (E) HVAC2 1373 9 DHW Sys 1 Existing Unchanged
OPAQUE SURFACES
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and
Door Area (ft2)Tilt (deg)Wall Exceptions Status Verified Existing
Condition
Front wall ADU R-15 Wall 250 Front 146 32 90 none New n/a
Left wall ADU R-15 Wall 340 Left 189 15 90 none New n/a
Right wall ADU R-15 Wall 160 Right 189 26 90 none New n/a
Front wall 2 (E) House Default Wall Prior to
197 250 Front 306 32 90 none Existing No
Left wall 2 (E) House Default Wall Prior to
197 340 Left 234 0 90 none Existing No
Rear wall (E) House Default Wall Prior to
197 70 Back 469 122 90 none Existing No
Right wall 2 (E) House Default Wall Prior to
197 160 Right 234 27 90 none Existing No
Interior front
wall to AD (E) House>>ADU R-15 Wall1 n/a n/a 146 0 n/a Existing No
Roof ADU R-30 Roof Attic n/a n/a 387 n/a n/a New n/a
Roof 2 (E) House Default Roof Prior to
197 n/a n/a 1373 n/a n/a Existing No
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 5 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
ATTIC
01 02 03 04 05 06 07 08 09 10
Name Construction Type Roof Rise
(x in 12)
Roof
Reflectance
Roof
Emittance
Radiant
Barrier Cool Roof Status Verified Existing
Condition
Attic ADU Attic RoofADU Ventilated 4 0.1 0.85 No No New n/a
Attic (E) House Attic Roof(E) House Ventilated 4 0.1 0.85 No No Existing No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
Name Type Surface Orientatio
n Azimuth Width
(ft)
Heigh
t (ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior
Shading Status
Verified
Existing
Condition
WN 03 Window Front wall Front 250 1 16 0.3 NFRC 0.23 NFRC Bug Screen New NA
WN 03 2 Window Front wall Front 250 1 16 0.3 NFRC 0.23 NFRC Bug Screen New NA
WN 04 Window Left wall Left 340 1 9 0.3 NFRC 0.23 NFRC Bug Screen New NA
WN 02 Window Left wall Left 340 1 6 0.3 NFRC 0.23 NFRC Bug Screen New NA
WN 01 Window Right wall Right 160 1 6 0.3 NFRC 0.23 NFRC Bug Screen New NA
WE 3040 Window Front wall 2 Front 250 1 12 0.55 NFRC 0.67 NFRC Bug Screen Existing No
DE 8068 Window Rear wall Back 70 1 54 0.55 NFRC 0.67 NFRC Bug Screen Existing No
WE 7640 Window Rear wall Back 70 1 30 0.55 NFRC 0.67 NFRC Bug Screen Existing No
WE 6030 Window Rear wall Back 70 1 18 0.55 NFRC 0.67 NFRC Bug Screen Existing No
WE 3030 Window Right wall 2 Right 160 1 9 0.55 NFRC 0.67 NFRC Bug Screen Existing No
WE 6030 2 Window Right wall 2 Right 160 1 18 0.55 NFRC 0.67 NFRC Bug Screen Existing No
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 6 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
OPAQUE DOORS
01 02 03 04 05 06
Name Side of Building Area (ft2)U-factor Status Verified Existing Condition
DN 01 Right wall 20 0.5 New n/a
DE 3068 Front wall 2 20 0.2 Existing No
DE 3068 2 Rear wall 20 0.2 Existing No
SLAB FLOORS
01 02 03 04 05 06 07 08 09 10
Name Zone Area (ft2)Perimeter (ft)
Edge Insul.
R-value and
Depth
Edge Insul.
R-value and
Depth
Carpeted Fraction Heated Status Verified Existing
Condition
Slab-on-Grade ADU 387 80 none 0 80%No New n/a
Slab-on-Grade 2 (E) House 1373 157 none 0 80%No Existing No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
Exterior Finish: 3 Coat Stucco
Default Wall Prior to
197 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-15 Wall1 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.086
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
Other Side Finish: Gypsum Board
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 7 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Attic RoofADU Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Attic Roof(E) House Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
R-30 Roof Attic Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032
Over Ceiling Joists: R-20.9 insul.
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
Default Roof Prior to
197
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-11 None / None 0.083
Over Ceiling Joists: R-1.9 insul.
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04 05
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50
Not Required Not Required N/A n/a n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name System Type Distribution
Type
Water Heater
Name
Number of
Units
Solar Heating
System
Compact
Distribution
HERS
Verification
Water Heater
Name (#)Status
Verified
Existing
Condition
Existing Water
Heating
System
DHW Sys 1 Domestic Hot
Water (DHW)Point of Use DHW Heater
1 1 n/a None n/a DHW Heater
1 (1)New NA
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 8 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
Name
Heating
Element
Type
Tank Type # of
Units
Tank Vol.
(gal)
Heating
Efficiency
Type
Efficiency Rated
Input Type
Input
Rating or
Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss or
Recovery
Eff
1st Hr.
Rating or
Flow Rate
Tank Location Status
Verified
Existing
Condition
DHW
Heater 1 Gas Consumer
Instantaneous 1 0 UEF 0.93 Btu/Hr 200000 0 n/a n/a New n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution
Type Recirculation Control Shower Drain Water Heat
Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name System Type Heating Unit
Name
Heating
Equipment
Count
Cooling Unit
Name
Cooling
Equipment
Count
Fan Name Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Existing HVAC
System
(N) HVAC1
Heat pump
heating
cooling
Heat Pump
System 1 1 Heat Pump
System 1 1 HVAC Fan 1
Air
Distribution
System 1
Setback New No
(E) HVAC2
Heating and
cooling
system other
Heating
Component
2
1
Cooling
Component
2
1 HVAC Fan 2
Air
Distribution
System 2
n/a Existing No
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 9 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
HVAC - HEATING UNIT TYPES
01 02 03 04 05
Name System Type Number of Units Heating Efficiency Heating Unit Brand
Heating Component 2 Central gas furnace 1 AFUE - 60 n/a
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08 09
Name System Type Number of Units Efficiency Metric Efficiency
EER/EER2/CEER
Efficiency
SEER/SEER2 Zonally Controlled Mulit-speed
Compressor HERS Verification
Cooling
Component 2 Central split AC 1 EER/SEER 11 12 Not Zonal Single Speed
Cooling
Component
2-hers-cool
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11 12 13
Name System Type Number of
Units
Heating Cooling
Zonally
Controlled
Compressor
Type HERS VerificationHeating
Efficiency
Type
HSPF/HS
PF2/COP Cap 47 Cap 17
Cooling
Efficiency
Type
SEER/SE
ER2
EER/EER
2/CEER
Heat Pump
System 1 Central split HP 1 HSPF 10 17000 13500 EERSEER 14 12 Not Zonal Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER/EER2 Verified
SEER/SEER2
Verified Refrigerant
Charge
Verified
HSPF/HSPF2
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 350 Not Required Not Required No Yes Yes Yes
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 10 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
Name Type Design Type
Duct Ins.
R-value
Duct
Location Surface Area
Bypass Duct Duct Leakage HERS
Verification Status
Verified
Existing
Condition
Existing
Distribution
system
New Ducts
>= 25 ftSuppl
y
Retur
n
Suppl
y
Retur
n
Suppl
y
Retur
n
Air
Distribution
System 1
Unconditio
ned attic
Non-
Verified R-6 R-6 Atti
c
Atti
c n/a n/a No Bypass
Duct
Sealed and
Tested
Air
Distribution
System
1-hers-dist
New n/a n/a
Air
Distribution
System 2
Unconditio
ned attic
Non-
Verified R-6 R-6 Atti
c
Atti
c n/a n/a No Bypass
Duct
Existing
(not
specified)
Air
Distribution
System
2-hers-dist
Existing No n/a
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC Fan 2 HVAC Fan 0.58 HVAC Fan 2-hers-fan
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 11 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
HVAC Fan 2-hers-fan Not Required 0
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:240140 Calculation Date/Time:2025-02-13T14:23:22-08:00 (Page 12 of 12)
Calculation Description:Title 24 Analysis Input File Name:GARAGE CONVERSION TO ADU Z8.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2025-02-13 14:23:27
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Truong Dong
Dong Engineering 02/13/2025
10692 silver cir
garden grove, CA 92843 (714) 204-2874
Truong Dong
Dong Engineering 02/13/2025
10692 silver cir N/A
garden grove, CA 92843 (714) 204-2874
425-P010047619A-000-000-0000000-0000 02/13/2025 14:23 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
SANTA ANA CITY COUNCIL
Mayor
vamezcua@santa-ana.org
Mayor Pro Tem, Ward 1
tphan@santa-ana.org
Ward 2
bvazquez@santa-ana.org
Ward 3
jessielopez@santa-ana.org
Ward 4
pbacerra@santa-ana.org
Ward 5
jryanhernandez@santa-ana.org
Ward 6
dpenaloza@santa-ana.org
MAYOR
Valerie Amezcua
MAYOR PRO TEM
Thai Viet Phan
COUNCILMEMBERS
Phil Bacerra
Johnathan Ryan Hernandez
Jessie Lopez
David Penaloza
Benjamin Vazquez
CITY OF SANTA ANA
PLANNING AND BUILDING AGENCY
20 Civic Center Plaza ● P.O. Box 1988
Santa Ana, California 92702
www.santa-ana.org
INTERIM CITY MANAGER
Tom Hatch
CITY ATTORNEY
Sonia R. Carvalho
CITY CLERK
Jennifer L. Hall
February 25, 2024
Also sent via email to: compasdesignservices@gmail.com
Maria Casas
1109 N Wright Street
Santa Ana, CA 92701
Subject: Address Assignment for an Accessory Dwelling Unit located at 2617 North Deodar
Street (APN: 396-273-12). in Santa Ana, CA
Dear Maria,
The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal
addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment
for a garage-conversion ADU located at 2617 North Deodar Street (APN: 396-273-12). Notice is
hereby given that the following assigned address shall be posted onsite per the approved address
plan, attached hereto as Exhibit A.
Address to be Activated/Posted
2617 North Deodar Street, Un
To subdivide commercial and/or residential units into multiple units, a building permit (and all other
associated permits), plans, and inspection approvals by the PBA are required. Address(es) will
be verified during inspections by the Building Safety Division.
Please update your records accordingly. Should you have any questions, feel free to contact me
by phone at (714) 664-2753 or by email at PRaj@santa-ana.org.
Sincerely,
Punkaj Raj
Planning Technician
Exhibit A – Address Plan
Address Letter for 2617 North Deodar Street
Page 2 of 2
c:
Vencent Quaglia, United States Post Office
Chris Tuiolosega, United States Post Office
Cipriano Corona, Marketing Manager, United States Post Office
Alex Alvarez, Postmaster Santa Ana, United States Post Office
Federal Express, Administration
Cathy Joseph, Garden Grove Unified School District
Christine Hy, Garden Grove Unified School District
Cathy Slader, Orange Unified School District
Orin Williams, Santa Ana Unified School District
Yvette Miranda, Santa Ana Unified School District
Cristina Bernal, Tustin Unified School District
Mishele Richards, Orange County Fire Authority, GEO Files Coordinator
Orange County Fire Authority
Neal Kelly, Registrar of Voters
Members, Board of Supervisors
Southern California Gas Company
Southern California Edison Company
Claude Parrish, County Assessor's Office
SAG, AT&T
UPS, Administration
City Manager’s Office
Beverly Martin, Police Community Services Specialist
Boris Duran, Police Systems Manager
Jennifer Mendoza, Police Communications Manager
Chris Hubbard, Police Systems Support Analyst
Alejandra Gutierrez, Treasury & Customer Services Manager
Hector Jimenez, Revenue Supervisor
Alfonso Chavez, Utilities Customer Services Supervisor
Judson Brown, Housing & Neighborhood Development Manager
Rudy Rosas, Principal Civil Engineer
Zdenek (Zed) Kekula, Principal Civil Engineer
Jason Kwak, Building Safety Manager
Evelyn LaRocca, Permit Supervisor
Kathy Hernandez, Permit Technician
Julie Amsden, Permit Technician
Ali Pezeshkpour, Planning Manager
Jerry Guevara, Senior Planner
Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager
N (ADU) 2617 N DEODAR STREET, UNIT 2
EXHIBIT A: ADDRESS PLAN
(E) PRIMARY DWELLING 2617 N DEODAR
STREET
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Submittal Criteria Form
Required for Single Family or Duplex Residences
(Use Commercial form for lots with 3+ dwelling units or new residential tracts)
Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification.
Project Information
New Single Family Residence/Duplex Addition/Remodel ADU Other
Address: Unit #: City or Unincorporated County Area: ZIP:
Scope of Work:
Existing Area to Total Resulting Stories: Area Added in Past 2 Years
Yes No Questionnaire OCFA Plan Type if “Yes”
1. New – Is this a new single family residence or duplex? *(PR160) Residential Site
with Water Availability
2. ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler
Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire
sprinkler retrofit based on a threshold set by local ordinance?
(PR400-402) Fire Sprinkler
4. Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site
5. Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non-
sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all
*(PR160) Residential Site
with Water Availability
6. Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or
removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed
(PR400-402) Fire Sprinkler
Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a
garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold
*(PR160) Residential Site
(PR400-402) Fire Sprinkler
8. Gate – Is a gate being installed across a driveway or road that is designated as a fire department
access roadway, or a driveway or road that serves more than a single home/duplex?
(PR180) Gate
9. Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal
Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas
seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only
applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000
*(PR160) Residential Site
*(PR172-174) Methane
Test/Mitigation Plans
10. Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to
slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation,
or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as
*(PR125) Fuel Modification
(PR182) Accessory
Structure
*OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals.
Applicant Certification
I certify, under penalty of perjury, under the laws of the State of California, that the information above is true:
Print Name:_______________________________________ Signature:___________________________________________ Date:______________
Phone Number:_____________________________________________ Email:_____________________________________________________________
Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a
written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required.
______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes”
and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral
Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination.
For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100
SFR