HomeMy WebLinkAbout2121 N Lewis St & Unit# 2 - Plan33 ' - 5 " 3'-7" 19'-4" 19'-9" 9'-2" 19 ' - 3 " 21 ' - 8 " 35'-4" 20 ' G E 27 ' - 3 " 24'-9" 48'-1" 4' (E) ELECTRIC METER 16 ' GA R A G E D O O R 19 ' - 7 " 5'-11" ±8'-3" TO L I N E O F C U R B O F N . L E W I S S T . 32 ' - 9 " 5'-11" 27 ' - 1 " 14 ' - 1 " 19 ' - 7 " ±1 6 ' - 7 " 17'-1" 90' (E) FENCE (E) GAS METER 10 4 ' - 7 " 13 0 ' - 5 " 4' 7'- 7 " 5' 10 ' - 1 0 " 10 ' - 1 " (E) PLANTER AREA (E) SIDEW A L K (E) GATE 26'-3" 19'-6" W (E) WATER METER (E) CONCRETE PAVEMENT A/C COND. UNIT (E) A/C CONDENSER DRYERWASHER (E) WASHER AND DRYER (E) WATER HEATER (N ) 4 " S (N ) 1 " W (N) 4" SEWER LINE. CONNECT TO EXISTING SEWER LATERAL AT PROPERTY LINE. CONSTRUCT PER CITY STANDARDS. CONSTRUCT (N) 1" WATER SERVICE ON THE PRIVATE SIDE TO CONNECT TO THE EXISTING WATER METER. CONSTRUCT PER CITY STANDARDS. FIRE SPRINKLERS NOT REQUIRED. DR A I N FL O W DR A I N FL O W DR A I N FL O W DR A I N FL O W DR A I N FL O W DR A I N FL O W DRAINFLOW DRAINFLOW DRAINFLOW DRAINFLOW DRAINFLOW DRAINFLOW DRAINFLOW DRAIN FLOW FLOW 10 ' PU E 47'-3"16'-2" SCE EASEME N T L I N E DRAINFLOW DRAINFLOW 10' SC E E A S E M E N T L I N E OPEN AREA #2121 EXISTING MAIN HOUSE (NOT IN CONTRACT) EXISTING 2-CAR GARAGE (NIC) 5'-11" 10'-4" 6' (E) CONCRETE PAVEMENT LINE OF (E) PATIO STRUCTURE LI N E O F ( E ) P A T I O S T R U C T U R E (E) PAVED AREA (N) PAVED AREA (N) CONCRETE WALK (E) CONCRETE PAVEMENT (E) CONCRETE DRIVEWAY (E) LANDSCAPE (E) PLANTER AREA (E) GATE (E) SIDEWALK (E) PLANTER AREA PR O P E R T Y L I N E PROPERTY LINEPR O P E R T Y L I N E LINE O F C U R B UNPERMITTED EXCESS DRIVEWAY TO BE ADDRESSED AT A LATER TIME (E ) F E N C E (E ) F E N C E PROPERTY L I N E 19 ' - 5 " (E) LANDSCAPE MAIN ENTRANCE #2121 - #2 PROPOSED ADU (750 SF) 13'-8" 5' - 5 " 22'-3" 47'-3" 11'-4" 6' 1'-11" A/C COND. UNIT (N) A/C CONDENSER DRAINFLOW DRAINFLOW DRAINFLOW E G(N) GAS METER (N) ELECTRIC METER AND PANELBOARD 200 AMP (NOTE : LOCATION TO BE VERIFIED BY SOCAL EDISON) NOTE: SOUTHERN CALIFORNIA EDISON (SCE) EASEMENT AND/OR OVERHEAD POWER LINE IS ADJACENT TO THE PROPOSED CONSTRUCTION, SCE REVIEW AND APPROVAL IS REQUIRED PRIOR TO FINAL PERMIT. (N) WATER HEATER, NEEA HEAT PUMP 65 GAL TANK RHEEM BRAND WH PROPOSED ACCESSORY DWELLING UNIT SCOPE OF WORK: OWNER'S INFORMATION: NAME :LINH LE AND DAVID FREUDENBERGER ADDRESS :2121 N. LEWIS ST., SANTA ANA, CA 92706-2236 CONTACT NO.:916.952.0890 TI T L E S H E E T A N D S I T E P L A N VICINITY MAP NOT TO SCALE N NOTE: PROJECT SITE IS WITHIN 0.4 MILE FROM PUBLIC TRANSPORT PROJECT SITE ASSESSOR'S MAP N PROJECT SITE 2121 N. LEWIS ST. AND 2121 N. LEWIS ST. #2 SANTA ANA, CA 92706-2236 PROPOSED SITE AND DRAINAGE PLAN SCALE : 1/8" = 1'-0" N EXISTING BUILDING INFORMATION: NO. OF UNITS :1 NO. OF STORY :1 BEDROOM :3 BATH :2 GARAGE :2-CAR CAPACITY SPRINKLER : NO SITE INFORMATION: ASSESSOR'S ID NO.: 101-561-19 LOT NO :52 DOC NO.:MM 133/13-15 MAP NO.:TR 3834 LEGAL DESCRIPTION :N TR 3834 BLK LOT 52 LOT AREA (SQ FT):8,278 PERIM (FT): 382 NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 LINH LE AND DAVID FREUDENBERGER 2121 N. LEWIS ST. AND 2121 N. LEWIS ST. #2, SANTA ANA, CA 92706-2236 PROPOSED BUILDING INFORMATION (ADU): ADU (SF):750 BEDROOM :2 BATH :2 STORY :1 CONSTRUCTION TYPE : V-B OCCUPANCY GROUP :R-3 BUILDING CODE: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA GREEN BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA ENERGY CODE 2023 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE SANTA ANA MUNICIPAL CODE EXISTING SFD EXISTING 2-CAR GARAGE PROPOSED A.D.U. TOTAL AREA 2,428 SF LOT COVERAGE : 1,278 SF 400 SF 750 SF MECHANICAL : HVAC DESIGN-BUILD ITEM. CONTRACTOR SHALL BE RESPONSIBLE IN HIRING MANUFACTURER WHO CAN DO DESIGN-BUILD OF HVAC. CONTRACTOR TO FOLLOW TITLE 24 RECOMMENDATION. ELECTRICAL : ELECTRICAL IS A DESIGN-BUILD ITEM/. CONTRACTOR IS RESPONSIBLE FOR HIRING LICENSED ELECTRICAL TO WORK ON ELECTRICAL LIGHTING, CONVENIENCE OUTLET, AND POWER PLAN; INCLUDING POWER/ELECTRICAL WIRING/LINE. PLUMBING : PLUMBING IS A DESIGN-BUILD ITEM. CONTRACTOR IS RESPONSIBLE FOR HIRING LICENSED PLUMBER TO WORK ON WATER, SEWER AND GAS; INCLUDING STORM-DRAIN PIPES AND FIRE SPRINKLER (IF APPLICABLE). CONTRACTOR SHALL COORDINATE WITH UTILITY PURVEYOR OR CITY INSPECTOR FOR THESE ITEMS. SHEET INDEX NO.NAME 00-G-000 TITLE SHEET 01-A-301 BUILDING ELEVATIONS 02-S0.1 STRUCTURAL NOTES FLOOR AND ROOF FRAMING PLAN EXISTING FLOOR PLAN AND ROOF PLAN 01-A-201 01-A-230 PROPOSED ROOF PLAN STRUCTURAL DETAILS STRUCTURAL DETAILS 01-A-302 BUILDING ELEVATIONS AND SECTIONS STRUCTURAL DETAILS 04-C-200 EXISTING SITE PLAN 1. PR0POSED ADU (750 SF) 2 BEDROOMS 2 BATHROOMS LIVING AREA DINING AREA KITCHEN TRELLIS (25.86 SF) PROPOSED FLOOR PLAN 00-G-000 2121 N. LEWIS ST. AND 2121 N. LEWIS ST. #2 SANTA ANA, CA 92706-2236 02-S1.1 02-S3.1 02-S3.2 02-S3.3 03-G-008 03-G-009 T24 T24 01-A-231 03-G-010 T24 CONSULTANT/DRAFTER: NAME : KM ASSOCIATES, INC. ENGINEER :MICHAEL SANTOS C-77657 ADDRESS :16202 ORION AVE., CHINO, CA 91708 CONTACT NO.:323-470-0181 LOT AREA = 8,278 SF 2,428 SFLOT COVERAGE = --------------- 8,278 SF LOT COVERAGE = 0.2933 OR 29.33% 03-G-005 03-G-006 CALGREEN CHECKLIST CALGREEN CHECKLIST DEFERRED SUBMITTAL: ELECTRICAL MECHANICAL PLUMBING RESIDENCE SQUARE FOOTAGE % NEW ADU 750 SF = -------------------- EXISTING SFD 1,278 SF = 0.5868 OR 58.68% 05-E-102 ELECTRICAL PLAN NOTE: THE ADU SF/SFD SF RATIO IS FOR PARK AND REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN "SFR SF" OF THE EXISTING PRIMARY RESIDENCE; BUILDIING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN "SFR SF" OF THE EXISTINGRESIDENCE. AREA 2.DEMOLITION OF PATIO TO BE CONVERTED TO OPEN AREA 26'-3" X 21'-8" (568.75 SF). 3.LEGALIZE A/C CONDENSER UNIT AT PRIMARY DWELLING. 4.CONNECT NEW SEWER AND WATER LINE TO EXISTING SEWER AND WATER LATERALS INSIDE PROPERTY. DEFERRED SUBMITTAL: NEW PHOTOVOLTAIC SYSTEM TO BE INSTALLED PER REQUIREMENTS OF PROVIDED ENERGY COMPLIANCE FORMS. APPROVED SOLAR PLANS AND ISSUED SOLAR PERMIT MUST BE PRESENTED TO BUILDING INSPECTOR PRIOR TO ROUGH FRAMING INSPECTIONS. BUILIDING SECURITY REGULATIONS NOTES : FOR NEW BUILDINGS AND ADDITIONS, ALTERATIONS, AND REPAIRS WITH ANY TWELVE-MONTH PERIOD EXCEED FIFTY (50%) PERCENT OF THE VALUE OF ANY EXISTING BUILDING OR STRUCTURE, EACH BUILDING OR STRUCTURE SHALL BE MADE TO CONFORM TO THE REQUIREMENTS FOR NEW BUILDINGS OR STRUCTURES AND COMPLY WITH THE BUILDING SECURITY REGULATIONS, SANTA ANA MUNICIPAL CODE CHAPTER 8, DIVISION 3. A COPY OF THE CONSTRUCTION DOCUMENTS OR A COMPARABLE DOCUMENT INDICATING THE INFORMATION FROM ENERGY CODE SECTIONS 110.10(B) THROUGH 110.10(C) SHALL BE PROVIDED TO THE OCCUPANT. IT aBBtM-•= D4 15 " 15 " 19 ' - 5 " 12'-10" MASTER'S BEDROOMBEDROOM #1 5' 36 " CL E A R 24''W X 24''H SD WINDOW W3 REFD/W 5' - 5 " 11' 33'-7" 47'-3" LIVING 13'-8" 10 ' - 1 0 " E (E) ELECTRIC METER (N) A/C CONDENSER (E) A/C CONDENSER WH A/C COND. UNIT #2121 EXISTING MAIN HOUSE (NOT IN CONTRACT) SD CM SD SD 50CFM EXHAUST FAN. DUCTED OUTSIDE THE BLDG. 5' CLOSET D4 D4 38 15 " 15 " 30" 30 " 30 " CL O S E T 11'-4" D3 W1 W3 W1 48''W X 48''H SD WINDOW W1 WASHER /DRYER STORAGE 30" 24''W X 24''H SLIDING WDW KITCHEN /DINING W2 36" CLEAR 36" CLEAR BATH #1 BATH #2 48''W X 48''H SLIDING WINDOW30 " 9' - 6 " MAIN ENTRANCE D1 48''W X 48''H SD WINDOW 48''W X 48''H SLIDING WINDOW W1W1 60" 48 " CLOSET 6' 5'W X 80''H FRENCH-TYPE SWING DOOR D2 8' W X 8 0 ' ' H SL I D I N G D O O R D3 50CFM EXHAUST FAN. DUCTED OUTSIDE THE BLDG. A/C COND. UNIT 30''W X 36''H SD WINDOW 16 ' - 3 " B A C 1' 1' EXISTING SFD (EAVES PROJECTION) 7.75" (THRESHOLD) PROVIDE 130 CFM (MIN) EXHAUST RATE KITCHEN HOOD OVER E-RANGE. LOCAL EXHAUST SYSTEM VENTED TO OUTDOORS 1-HR FIRE-RATED WALL 2 01-A-230 RANGE SD CM SD CM E G 2 01-A-230 NOTE: ELECTRIC RANGE, NO GAS HOOK ON STOVE. (N) WATER HEATER, NEEA HEAT PUMP 65 GAL TANK RHEEM BRAND (E) FENCE 10 ' PU E SCE EASEME N T L I N E SC E E A S E M E N T L I N E PROPERTY L I N E 10' PUE 5'-11" PR O P E R T Y L I N E PR O P E R T Y L I N E PROVIDE IAQ EXHAUST FAN TYPE 0.35 FAN EFFICIENCY 45 CFM AIRFLOW PER T24 30'' WIDE X 22'' DEPTH ATTIC ACCESS IPL PROPOSED ADU (EAVES PROJECTION)2' 2' 1-HR FIRE-RATED WALL PER CRC TABLE R302.1(1) 15 02-S3.1 1-HR FIRE-RATED EAVES PER CRC TABLE R302.1(1) PR O P O S E D F L O O R P L A N NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 SCALE 1/4" = 1'-0" PROPOSED FLOOR PLAN (ADU)1 NOTES: 1.FINISH MATERIAL INCLUDING SEALANTS, CAULK, PAINTS AND COATINGS, ADHESIVES, CARPET SYSTEMS, ETC.SHALL MEET THE (VOC) EMISSION LIMITS PER LAC GBSC CHAPTER 4. 2.OPENING SHALL HAVE CORROSION-RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL WITH 1/16'' MINIMUM AND 1/4'' MAXIMUM OPENING. 3.A MINIMUM OF 1'' AIRSPACE SHALL BE PROVIDED BETWEEN INSULATION AND ROOF SHEATHING. 4.CLOTHES DRYER MOISTURE EXHAUST DUCT MUST BE 4" IN DIAMETER AND LENGTH SHALL BE REDUCED BY 2' FOR EVERY ELBOW IN EXCESS OF TWO. ADDITIONAL NOTES ON ALARMS: 1.THE ALARM SHALL PROVIDE AN AUDIBLE WARNING WHEN THE DOOR OR ITS SCREEN, IF PRESENT, ARE OPENED. 2.THE ALARM(S) SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 2017 AND INDEPENDENTLY CERTIFIED TO THE ASTM STANDARD F2208. 3.THE ALARMS SHALL BE EQUIPPED WIT H A DEACTIVATION SWITCH LOCATED IN ACCORDANCE 54" ABOVE THE FLOOR FOR UNITS NOT REQUIRED TO BE ACCESSIBLE, AND BETWEEN 48 AND 54 INCHES FOR UNITS REQUIRED TO BE ACCESSIBLE. 01-A-201 1.SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEAD SHALL BE FINISHED WITH NON-ABSORBENT SURFACE TO HEIGHT NOT LESS THAN 6' ABOVE FLOOR. 2.REINFORCEMENT FOR GRAB BARS MUST BE INSTALLED IN ONE BATHROOM ON THE ENTRY LEVEL IN ACCORDANCE WITH SECTION R327.1.1. 3. REINFORCEMENT SHALL BE LOCATED BETWEEN 32-INCHES AND 39 1/4-INCHES ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL. 4. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ON ONE SIDE WALL AND THE BACK WALL. 5.ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48-INCHES MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15-INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. (CRC R327.1.2). 6.DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48-INCHES ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. (CRC R327.1.4). CMSD LEGEND: PROPOSED SHEAR WALL PROPOSED WALL. "SMOKE ALARM" SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP AND SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72. "CARBON MONOXIDE ALARM" SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP. 50CFM ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE TO THE OUTSIDE OF THE BUILDING. FANS, NOT FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, MUST BE CONTROLLED BY A HUMIDITY CONTROLLER. SUPPLY DIFFUSER (SA) RETURN AIR GRILLE (RA) BATHROOM NOTES: ADDITIONAL NOTES: 1 "ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT." (4.504.1) 2."ARCHITECTURAL PAINTS AND COATINGS, ADHESIVES, CAULKS AND SEALANTS SHALL COMPLY WITH THE VOLATILE ORGANIC COMPOUND (VOC) LIMITS LISTED IN TABLES 4.504.1-4.504.3." 4.504.2.1-4.504.2.3 3.LACRC SECTION T327 AGING-IN PLACE DESIGN AND FALL PREVENTION INCORPORATED IN THE DESIGN REQUIREMENTS. ANNULAR SPACED AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR SIMILAR METHODS (4.406.1) MATERIAL CONSERVATION AND RESOURCE EFFICIENCY NOTES : 49'-3" 1' 1' 16 ' - 3 " 13'-8"1' 1' 11 ' - 3 1 2" 47'-3"1'1' 1'1' DRAIN AND SCUPPERS. SEE DETAIL.DRAIN AND SCUPPERS. SEE DETAIL. ROOF DRAIN FLOW 15/32'' OSB W/ RADIANT BARRIER W/ 8D SPACED @ 6''-6''-12''. ROOF DRAIN FLOW 8' - 1 1 2" RO O F D R A I N F L O W RO O F D R A I N F L O W ROOF DRAIN FLOW ROOF DRAIN FLOW DR A I N F L O W 15/32'' OSB W/ RADIANT BARRIER W/ 8D SPACED @ 6''-6''-12''. 15/32'' OSB W/ RADIANT BARRIER W/ 8D SPACED @ 6''-6''-12''. SL O P E SL O P E SL O P E SLOPE SLOPE 4:12 #2121 EXISTING MAIN HOUSE (NOT IN CONTRACT) 4: 1 2 4:12 DR A I N F L O W DRAIN AND SCUPPERS. SEE DETAIL. ROOF DRAIN FLOW DRAIN AND SCUPPERS. SEE DETAIL. DRAIN AND SCUPPERS. SEE DETAIL. 4:12 15'-8" 18 ' - 3 " 6' AD U W A L L TO S F D W A L L 4' IP L A D U TO I P L S F D IPL (EAVES PROJECTION) OF EXISTING SFD IP L ( E A V E S P R O J E C T I O N ) OF E X I S T I N G S F D IP L ( E A V E S P R O J E C T I O N ) OF E X I S T I N G S F D IPL (EAVES PROJECTION) OF NEW ADU COOL ROOF SHINGLES TRUDEFINITION DURATION COOL PLUS PER CRRC PRODUCT ID 0890-0034a. SEE OWENS CORNING, REFER TO MANUFACTURER'S STANDARD AND SPECIFICATIONS FOR INSTALLATION. VERIFY EXISTING ROOFING OF MAIN HOUSE. COOL ROOF SHINGLES PER CRRC 0890-0010. SEE OWENS CORNING, REFER TO MANUFACTURER'S STANDARD AND SPECIFICATION FOR INSTALLATION. COOL ROOF SHINGLES TRUDEFINITION DURATION COOL PLUS PER CRRC PRODUCT ID 0890-0034a. SEE OWENS CORNING, REFER TO MANUFACTURER'S STANDARD AND SPECIFICATIONS FOR INSTALLATION. VERIFY EXISTING ROOFING OF MAIN HOUSE. 4: 1 2 PR O P O S E D R O O F P L A N NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 SCALE 1/4" = 1'-0"1.2 POPOSED OOF PLA1 NOT TO SCALE ROOF DRAIN DETAIL3 01-A-230 ATTIC VENTILATION TYPE OF VENT : 92.4 SQ IN O'HAGIN 14" X 24" TAPERED LOW PROFILE VENT NOT TO SCALE 1-HR FIRE-RATED WALL2 1 HOUR RATE LATH AND PLASTER (7/8") OR ONE LAYER OF (5/8") TYPE "X" GYPSUM BOARD EACH SIDE MINERAL FIBER INSULATION (NOTE 2) RESILIENT CLIP AT EACH STUD OR RESILIENT CHANNELS-ONE SIDE 2"X4" STUDS AT 16" O.C. 5/8" TYPE X DRY WALL 1.THE TYPE AND SPACING OF RESILIENT CHANNELS AND CLIPS AND THE ATTACHMENT OF GYPSUM BOARD OR LATH SHALL BE AS REQUIRED FOR FIRE RATINGS. 2.THE MINERAL FIBER INSULATION SHALL HAVE A THERMAL RESISTANCE R VALUE OF 15 OR GREATER AS DETERMINED BY FEDERAL SPECIFICATION RR-I-521B. 3.NO TEST IS ON FILE TO JUSTIFY AN STC 50 WITH ONE 5/8" TYPE "X" GYPSUM BOARD ON EACH SIDE. GENERAL NOTES: *ATTIC VENTILATION SHALL NOT LESS THAN 1/150 OF THE ATTIC AREA. A. ATTIC AREA = 43.35 SF = 43.35 X 144 = 6,242.40 SI B. NO. OF VENT = 6,242.40 / 150 = 41.62 SF OF VENT = 41.62 / 92.4 SQ.IN. REQ'D VENTS = 1 VENT A. ATTIC AREA = 706.65 SF = 706.65 X 144 = 101,757.60 SI B. NO. OF VENT = 101,757.60 / 150 = 678.38 SF OF VENT = 678.38 / 92.4 SQ.IN. REQ'D VENTS = 8 VENTS 1. @ CALIFORNIA FRAMING AREA 2. @MAIN ROOF AREA 3'-7" 19'-4" 19'-9" 19 ' - 3 " (E) 2-CAR GARAGE (E) RECEPTION AREA 21 ' - 8 " 20'-7"10'-1"10'-6" 10 ' - 2 " 3' 14 ' - 1 " 13'8' (E) BEDROOM #3 (E) BEDROOM #1 (E) KITCHEN (E) BEDROOM #2 15 " 15 " 15"15" 3'-9" 20 ' CL O S E T CLOSET CLOSET (E) BATH #1 (E) BATH #2 G E 27 ' - 3 " 24'-9" 48'-1" 4' 16 ' GA R A G E D O O R 19 ' - 7 " 14 ' - 1 " 14'-9"9'-2" 33 ' - 8 " (E) DINING AREA 7' - 0 1 2" 6' - 2 1 2" SD SD SD REFD/W DRYERWASHER PA N T R Y CA B I N E T OVEN G E (E) ELECTRIC METER (E) GAS METER A/C COND. UNIT (E) A/C CONDENSER (E) WASHER AND DRYER (E) WATER HEATER SD CM SD CM 4:12 19'-4" 19 ' - 3 " 21 ' - 8 " 20 ' 27 ' - 3 " ±48'-1" 14 ' - 1 " ±34'-11"12'-9" ±6 0 ' - 1 1 " 4:12 4:12 4: 1 2 4: 1 2 4: 1 2 4: 1 2 4: 1 2 (E) MAIN HOUSE ROOFING TO REMAIN, PROTECT IN PLACE (E) MAIN HOUSE ROOFING TO REMAIN, PROTECT IN PLACE EX I S T I N G F L O O R P L A N AN D R O O F P L A N SCALE 1/4" = 1'-0" EISTING LOOR PLAN1 NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 1/4" = 1'-0" EISTING ROO PLAN 01-A-231 SCALE2 ADDITIONAL NOTE : SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS IN EXISTING BUILDING SHALL BE FIELD VERIFIED AND NEW DETECTORS INSTALLED WHERE REQUIRED/MISSING IN COMPLIANCE WITH CRC R314 & CRC R315. TOP PLATE TOP OF ROOF 4' 9' FLOOR LINE GRADE 13 ' 1'-6" ED TOP PLATE TOP OF ROOF FLOOR LINE GRADE 1'-6" 1' - 2 " 1' - 4 " 1'-6" 8" TOP PLATE TOP OF ROOF 9' FLOOR LINE GRADE 1' 35 " 44 " M A X W1 TOP PLATE TOP OF ROOF FLOOR LINE GRADE STUCCO FINISH, COLOR TO MATCH EXISTING, VIF STUCCO FINISH, COLOR TO MATCH EXISTING, VIF W1 EAVES WITH 1-HR FIRE- RESISTANT RATING 15/32'' OSB W/ RADIANT BARRIER W/ 8D SPACED @ 6''-6''-12''. NOTE: WINDOW TRIM AND GRILLE INSERTS TO MATCH EXISTING MAIN HOUSE 1' 8" 3' - 7 " 9' 3' - 7 " EAVES WITH 1-HR FIRE- RESISTANT RATING 8" 13 ' - 3 " 13 ' - 3 " COOL ROOF SHINGLES TRUDEFINITION DURATION COOL PLUS PER CRRC PRODUCT ID 0890-0034a. SEE OWENS CORNING, REFER TO MANUFACTURER'S STANDARD AND SPECIFICATIONS FOR INSTALLATION. VERIFY EXISTING ROOFING OF MAIN HOUSE. TOP PLATE TOP OF ROOF 9' FLOOR LINE GRADE 1' 35 " 44 " M A X TOP PLATE TOP OF ROOF FLOOR LINE GRADE STUCCO FINISH, COLOR TO MATCH EXISTING, VIF STUCCO FINISH, COLOR TO MATCH EXISTING, VIF EAVES WITH 1-HR FIRE- RESISTANT RATING 15/32'' OSB W/ RADIANT BARRIER W/ 8D SPACED @ 6''-6''-12''. NOTE: WINDOW TRIM AND GRILLE INSERTS TO MATCH EXISTING MAIN HOUSE 1' 8" 3' - 7 " 9' 3' - 7 " EAVES WITH 1-HR FIRE- RESISTANT RATING 8" 13 ' - 3 " 13 ' - 3 " W1 W3 W2 (N) TANKLESS WATER HEATER, IN A RECESSED ENCLOSURE. (N) A/C COND. UNIT 3' - 2 " COOL ROOF SHINGLES TRUDEFINITION DURATION COOL PLUS PER CRRC PRODUCT ID 0890-0034a. SEE OWENS CORNING, REFER TO MANUFACTURER'S STANDARD AND SPECIFICATIONS FOR INSTALLATION. VERIFY EXISTING ROOFING OF MAIN HOUSE. DOOR SCHEDULE TAG 1 SIZE THICK MATERIALWIDE(") X HEIGHT(")TYPE GLAZING SELF-LATCH SELF-CLOSING WINDOW SCHEDULE TAG 1 SIZE MATERIAL GLASS, TEMPERED WIDE(") X HEIGHT(") 48 48 GLAZING DOUBLE 0.30 U-FACTOR 0.20 SHGC TYPE SLIDING 1 3/4''WOOD3680 NO NO NO 2 1 3/4''GLASS6080 YES NO NO 3 2 GLASS, TEMPERED3036 DOUBLE 0.30 0.20 3 GLASS, TEMPERED DOUBLE 0.30 0.20 HINGE HINGE 4 1 3/4''WOOD34-36 80 NO NO NOHINGE SLIDING 24 24 SLIDING 1 3/4''WOOD3280 NO NO NOHINGE BU I L D I N G E L E V A T I O N S SCALE 1/4" = 1'-0" FRONT ELEATION (EXISTING MAIN HOUSE)1 NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 1/4" = 1'-0" FRONT ELEATION (ADU) SCALE 1/4" = 1'-0" REAR ELEATION (ADU)3 01-A-301 SCALE3 NOTE : DESIGN CRITERIA : ROOF DEAD LOAD = 10 PSF ROOF LIVE LOAD = 20 PSF TOP PLATE TOP OF ROOF 9' FLOOR LINE GRADE 1' 8" (N) A/C COND. UNIT TOP PLATE TOP OF ROOF FLOOR LINE GRADE EAVES WITH 1-HR FIRE- RESISTANT RATING 1' 3' - 2 " STUCCO FINISH, COLOR TO MATCH EXISTING, VIF 9' 8" NOTE: WINDOW TRIM AND GRILLE INSERTS TO MATCH EXISTING MAIN HOUSE 3' - 7 " 80 EAVES WITH 1-HR FIRE- RESISTANT RATING 13 ' - 3 " 12 ' - 1 0 " COOL ROOF SHINGLES TRUDEFINITION DURATION COOL PLUS PER CRRC PRODUCT ID 0890-0034a. SEE OWENS CORNING, REFER TO MANUFACTURER'S STANDARD AND SPECIFICATIONS FOR INSTALLATION. VERIFY EXISTING ROOFING OF MAIN HOUSE. TOP PLATE TOP OF ROOF 9' FLOOR LINE GRADE 1' 8" (N) A/C COND. UNIT TOP PLATE TOP OF ROOF FLOOR LINE GRADE EAVES WITH 1-HR FIRE- RESISTANT RATING 1' 3' - 7 " STUCCO FINISH, COLOR TO MATCH EXISTING, VIF 9' 8" NOTE: WINDOW TRIM AND GRILLE INSERTS TO MATCH EXISTING MAIN HOUSE 3' - 2 " EAVES WITH 1-HR FIRE- RESISTANT RATING 35 " 44 " M A X W1 W3 (N) TANKLESS WATER HEATER, IN A RECESSED ENCLOSURE. 13 ' - 3 " 12 ' - 1 0 " COOL ROOF SHINGLES TRUDEFINITION DURATION COOL PLUS PER CRRC PRODUCT ID 0890-0034a. SEE OWENS CORNING, REFER TO MANUFACTURER'S STANDARD AND SPECIFICATIONS FOR INSTALLATION. VERIFY EXISTING ROOFING OF MAIN HOUSE. TOP PLATE TOP OF ROOF 9' FLOOR LINE GRADE 1' TOP PLATE TOP OF ROOF FLOOR LINE GRADE EAVES WITH 1-HR FIRE- RESISTANT RATING 1' 8" 3' - 7 " 9' 3' - 7 " EAVES WITH 1-HR FIRE- RESISTANT RATING 8" 13 ' - 3 " 13 ' - 3 " 2"X8" CEILING JOIST @16'' O.C. 2X6 @ 16'' O.C. WALL STUD WITH R-19 INSULATION PER T24, WITH 2X6 BOTTOM PLATE BATH #2BEDROOM #1BATH #1 MASTER'S BEDROOM KITCHEN/DINING /LIVING AREA (N) 4'' THK. CONCRETE SLAB W/ #4 REBARS @ 16'' O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 2"X8" ROOF RAFTER @ 16'' O.C. W/ R-38 INSULATION PER T24 COOL ROOF SHINGLES TRUDEFINITION DURATION COOL PLUS PER CRRC PRODUCT ID 0890-0034a. SEE OWENS CORNING, REFER TO MANUFACTURER'S STANDARD AND SPECIFICATIONS FOR INSTALLATION. VERIFY EXISTING ROOFING OF MAIN HOUSE. 2X4 @ 16'' O.C. WALL STUD 2X4 @ 16'' O.C. WALL STUD 2X4 @ 16'' O.C. WALL STUD 2X4 @ 16'' O.C. WALL STUD 2X6 @ 16'' O.C. WALL STUD WITH R-19 INSULATION PER T24, WITH 2X6 BOTTOM PLATESHEAR WALL TOP PLATE TOP OF ROOF 9' 1' FLOOR LINE GRADE 3' - 2 " 2X6 @ 16'' O.C. WALL STUD W/ R-19 INSULATION PER T24, WITH 2X6 BOTTOM PLATE 2"X8" CEILING JOIST @16'' O.C. 2"X8" ROOF RAFTER @ 16'' O.C. W/ R-38 INSULATION PER T24 8" 12 ' - 1 0 " KITCHEN / DINING (N) 4'' THK. CONCRETE SLAB W/ #4 REBARS @ 16'' O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 2X6 @ 16'' O.C. WALL STUD W/ R-19 INSULATION PER T24, WITH 2X6 BOTTOM PLATE TOP PLATE TOP OF ROOF 9' 1' FLOOR LINE GRADE 3' - 7 " 2X6 @ 16'' O.C. WALL STUD WITH R-19 INSULATION PER T24; WITH 2X6 BOTTOM PLATE 2"X8" CEILING JOIST @16'' O.C. 2"X8" ROOF RAFTER @ 16'' O.C. W/ R-38 INSULATION PER T24 13 ' - 3 " 8" BEDROOM #1 HALL WAY 2X6 @ 16'' O.C. WALL STUD WITH R-19 INSULATION PER T24; WITH 2X6 BOTTOM PLATE 2X4 @ 16'' O.C. WALL STUD (N) 4'' THK. CONCRETE SLAB W/ #4 REBARS @ 16'' O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. BU I L D I N G E L E V A T I O N S A N D S E C T I O N S NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 SCALE 1/4" = 1'-0" LET -SE ELEATN A1 SCALE 1/4" = 1'-0" T SE ELEATN A SCALE NTS LASN ETAL 1 SCALE LASN ETAL 2 NTS SCALE 1/4" = 1'-0" SECTN A LNTNAL VIEW FROM LEWIS ST. 1 VIEW FROM LEWIS ST. 2 01-A-302 SCALE 1/4" = 1'-0" SECTN ALN EM 1 SCALE SECTN C TCEN/NN 1/4" = 1'-0" 2 3 4 5 7 NOTE : DESIGN CRITERIA : ROOF DEAD LOAD = 10 PSF ROOF LIVE LOAD = 20 PSF NON-SHRINK GROUT #23616FIVE STAR GROUT HOLD-DOWNS SIMPSON HOLD-DOWNS #24818 #24947, #25076SIMPSON JOIST HANGERSJOIST HANGERS #22086SIMPSON FTA5 STRAPSTRAPS SET "XP" EPOXY #25279SIMPSON EPOXY ANCHOR LARR NUMBERS SEISMIC DESIGN CRITERIA A) Importance Factor, i = 1 B)EXPOSURE = C C)WIND VELOCITY = 110 MPH WIND DESIGN CRITERIA C.REINFORCING STEEL 1.ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE, CONFORMING TO A.S.T.M.(A-615-40), U.N.O. 2.USE LOW HYDROGEN ELECTRODES, GRADE (E-70), FOR WELDING REINFORCING BARS. 3.REINFORCING BARS MARKED CONT. SHALL BE SPLICED WITH A MINIMUM LAP OF (40) BAR DIAMETERS IN MASONRY AND (36) DIAMETERS IN CONCRETE. 4.ALL REINFORCING SHALL BE SECURELY TIED AND BRACED IN PLACE PRIOR TO POURING CONCRETE OR PLACING MASONRY. 5.PROVIDE THE FOLLOWING MINIMUM PROTECTIVE COVERING OF CONCRETE OVER REINFORCING STEEL. BELOW GRADE (UNFORMED)----------------3" CLR. BELOW GRADE (FORMED)--------------------2" CLR. H.NAILING SCHEDULE COMMON WIRE NAILS 1.JOIST TO SILL OR GIRDER TOE NAIL---------------------------------------------------------------------------------------------3-8d 2.BRIDGING TO JOIST TOE NAIL EACH END--------------------------------------------------------------------------------------2-8d 3.1" BY 6" SUBFLOOR OR LESS TO EACH JOIST FACE NAIL----------------------------------------------------------------2-8d 4.WIDER THAN 1" BY 6" SUBFLOOR TO EACH JOIST FACE NAIL----------------------------------------------------------3-8d 5.2" SUBFLOOR TO JOIST OR GIRDER BLIND AND FACE NAIL-----------------------------------------------------------2-16d 6.SOLE PLATE TO JOIST OR BLOCKING FACE NAIL--------------------------------------------------------------16d @16" O/C 7.TOP PLATE TO STUD END NAIL---------------------------------------------------------------------------------------------------2-16d 8.STUD TO SOLE PLATE TOE NAIL---------------------------------------------------------------------------------------------------4-8d 9.DOUBLED STUDS FACE NAIL------------------------------------------------------------------------------------------16d @24" O/C 10.DOUBLED TOP PLATES FACE NAIL----------------------------------------------------------------------------------16d @16" O/C 11.TOP PLEATES, LAPS & INTERSECTIONS FACE NAIL----------------------------------------------------------------------2-16d 12.CONTINUOUS HEADER, TWO PIECES ALONG EACH SIDE--------------------------------------------------16d @16" O/C 13.CEILING JOISTS TO PLATE FACE NAIL-------------------------------------------------------------------------------------------3-8d 14.CONTINUOUS HEADER TO STUD TOE NAIL------------------------------------------------------------------------------------4-8d 15.CEILING JOISTS, LAPS OVER PARTITIONS FACE NAIL-------------------------------------------------------------------3-16d 16.CEILING JOISTS TO PARALLEL RAFTERS FACE NAILS-------------------------------------------------------------------3-16d 17.RAFTER TO PLATE TOE NAIL--------------------------------------------------------------------------------------------------------3-8d 18.1 BY BRACE TO EACH STUD AND PLATE FACE NAIL-----------------------------------------------------------------------2-8d 19.1 BY 8 SHEATING OR LESS TO EACH BEARING FACE NAIL--------------------------------------------------------------2-8d 20.WIDER THAN 1 BY 8 SHEATHING TO EACH BEARING FACE NAIL------------------------------------------------------3-8d 21.BUILT-UP CORNER STUDS----------------------------------------------------------------------------------------------16d @24" O/C 22.BUILT-UP GIRDER AND BEAMS: AT TOP & BOTTOM & STAGGERED--------------------------------------------------------------------------------20d @32" O/C AT ENDS & AT EACH SPLICE-----------------------------------------------------------------------------------------------------2-20d 23.2 BY PLANKS AT EACH BEARING-------------------------------------------------------------------------------------------------2-16d GENERAL NAILING NOTES 1.NAILS SHALL BE DRIVEN PERPENDICULAR WHERE POSSIBLE INSTEAD OF TOE NAILS. 2.PRE-DRILL FOR ALL NAILS 30d OR LARGER. 3.ALL NAILS SHALL BE COMMON WIRE NAILS UNLESS OTHERWISE NOTED. A.GENERAL NOTES D.SHEAR WALL (T2306.4.1) NDS) E.LUMBER / FRAMING 11.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR LARCH OF THE FOLLOWING GRADES UNLESS NOTED OTHERWISE: PLYWOOD PANELS--------------------------STRUCTURAL I OR II, CDX EXT. GLUE CONFORMING TO PS-1-83 PLATES, BLOCKING-------------------------------------------------------------------------------------------------CONST. -875fb BEAMS, STRINGERS (4x)-------------------------------------------------------------------------------------------------#1-1000fb POST & BEAMS (>4x)-------------------------------------------------------------------------------------SEL. STRUCT. -1600fb ROOF PLANKING & DECKING-------------------------------------------------------------------------------COM. DEX. -875fb JOISTS & PLANKING--------------------------------------------------------------------------------------------------------#2 -875fb RAFTERS ----------------------------------------------------------------------------------------------------------------------#2 -875fb BOARDS, SHEATHING & STRIPPING------------------------------------------------------------------------CONST. GRADE SILLS, PLATES, SLEEPERS, POSTS OR WOOD EMBEDDED IN CONCRETE SLAB WHICH IS IN CONTACT WITH EARTH--------CONST. GRADE, PRESSURE TREATED MISC. NAILING STRIPS & BLOCK EMBEDDED IN CONCRETE OR MASONRY------------------------------GRADE SPECIFIED ABOVE, TANK DIPPED IN SALT PERSERVATIVE 12.ALL BREAKS FOR VENTS, DUCTS, PLUMBING SHALL BE STRAPPED WITH 1 1/2 x 1/8 STEEL STRAPS WITH 4-16d NAILS EACH SIDE. 13.HEADER SIZE NOT SHOWN SHALL BE PER UBC STANDARDS AND 4x4 MIN. 14.PROVIDE HOLDDOWNS (FTA, HD, PA, VERT. MST, ETC.) W/ DBL OR 4x STUD WITH E.N. 15.HANGER FOR 2x JST SHALL BE SIMPSON "U", FOR 4x OR 6x PURLIN SHALL BE SIMPSON "HUTF", U.N.O. 16.DBL. JOIST SHALL BE NAILED TOGETHER WITH 16d @ 9" O.C., STAGGER, U.N.O. 17.TIE ROOF RAFTERS AT RIDGE W/ ST 2115 @ 4'-0" 0/C. 18.NOTCHING OF EXTERIOR AND BEARING / NONBEARING WALLS SHALL NOT EXCEED 25% / 40% RESPECTIVELY. BORED HOLES IN BEARING / NONBEARING WALLS SHALL NOT EXCEED 40% / 60% RESPECTIVELY. 19.PLYWOOD ROOF PANELS SHALL BE BONDED WITH INTERMEDIATE OR EXTERIOR GLUE AND BE OF EXTERIOR TYPE WHERE EXPOSED TO THE WEATHER. 20.DOUBLE JOISTS ARE REQUIRED UNDER PARALLEL BEARING PARTITIONS. U.N.O. 21.THE REQUIRED CLEARANCE FOR WOOD MEMBERS ABOVE GRADE, IS 6" FOR MUDSILLS, 12" FOR GIRDERS, AND 18" FOR JOISTS. 22.ROOF DIAPHRAGM SHALL BE 1/2" PLYWOOD, PANEL INDEX 24/0, NAIL 8d @ 6", 12". FLOOR DIAPHRAGM SHALL BE 5/8" PLYWOOD, PANEL INDEX 32/16, T&G, NAIL 10d @ 6", 10", U.N.O. 23.LAY PLYWOOD PANEL STAGGERED W/ FACE GRAIN PERPENDICULAR TO SUPPORTS. 24.ALL DOUBLE TOP PLATES ARE TO BE CONTINUOUS BY NAILING OR STRAPS. SPLICE @4'-0"MIN. W/12-6d NAILS EACH SIDE OF SPLICE WHERE INTERRUPTED, TIE TOP PLT'S W/ SIMPSON MST 37, U.N.O. 25.ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIP GALVANIZED AFTER FABRICATION. 26.EACH SHEET OF PLYWOOD SHALL CONTAIN A MINIMUM OF (8) SQ. FT. AND SHALL EXTEND TO (3) BEARINGS MINIMUM WITH FACE-GRAIN PERPENDICULAR TO JOISTS. 27.PROVIDE EDGE NAILING OVER ALL WALLS, LAMINATED BEAMS, STRUTS AND ALL AROUND OPENINGS. 28.PROVIDE BOUNDARY NAILING AT PERIMETER OF BUILDING AND AT ALL CONTINUOUS PLYWOOD EDGES. 29.PROVIDE FULL BEARING ON ALL BEAMS AND JOISTS HANGERS; IF EXCESSIVE SHRINKAGE OCCURS, PROVIDE HANDWARE SHIMS, WHICH SHALL BE SECURED TO JOISTS. B.CONCRETE 1.ALL CONCRETE SHALL CONFORM TO THE 2022 CALIFORNIA RESIDENTIAL CODE AND CBC. 2.CONCRETE SHALL BE DESIGNED AND TESTED AS OUTLINED IN THE SPECS. 3.ALL CEMENT SHALL CONFORM TO A.S.T.M. (C-150), TYPE I OR II 4.FINE AND COARSE AGGREGATE SHALL CONFORM TO A.S.T.M. (C-33) FOR STANDARD WEIGHT CONCRETE AND A.S.T.M. (C-330) FOR LIGHT WEIGHT CONCRETE. 5.ALL AGGREGATE SHALL BE COMPARABLE TO "SAN GABRIEL VALLEY" AGGREGATE. THE SHRINKAGE SHALL BE PER A.S.T.M. (C-157) WITH THE AVERAGE DRYING SHRINKAGE AT (28 DAYS) OF DRYING NOT EXCEEDING (0.04%) 6.DRYPACK SHALL BE COMPOSED OF ONE PART PORTLAND CEMENT TO NOT MORE THAN THREE PARTS SAND. 7.ANCHOR BOLTS, DOWELS, INSERTS, ETC. SHALL BE SECURELY TIED IN PLACE PRIOR TO POURING CEMENT. 8.LOCATION OF CONSTRUCTION JOINTS OR POUR JOINTS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO POURING CONCRETE. 9.CONCRETE SHALL BE CURED BY KEEPING CONTINUOUSLY WET FOR (10 DAYS) OR BY AN APPROVED CURING COMPOUND. 10.REFER TO ARCHITECTUAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR MISCELLANEOUS ITEMS TO BE CAST INTO CONCRETE AND FLOOR DEPRESSIONS, ETC. 11.SEE ARCHITECTUAL DRAWINGS FOR LOCATION OF EXPANSION JOINTS, SCORING, ETC. FOR CONCRETE WALKS AND SLABS. 12.FOOTING AND GRADE BEAM SHALL BE F'c=2,500 PSI AT 28 DAYS. 12.ALL CONCRETE STRUCTURES SHALL HAVE A MINIMUM COMPRESSION STRENGTH OF F'c = 3,000 PSI AT 28 DAYS, UNLESS NOTED OTHERWISE. 13.PROVIDE INTERIOR SLAB CONTROL JOINTS AT MAXIMUM 20FT. O.C. EACH WAY. 14.NO WOOD OR STEEL STAKES SHALL BE PERMITTED TO BE LEFT IN FOOTINGS. 15.BOT. OF FTG. SHALL BE 18" MIN. FOR 1-STORY BLDG., 24" MIN. FOR 2-STORY BLDG., 24" MIN. FOR 3-STORY BLDG. OR EXPANSIVE SOIL BELOW NATURAL GRADE, U.N.O. 16.ALL PADS SHALL BE 14" THICK MIN. W/ #4 @ 12" E.W. AR BOT., U.N.O. F. STATEMENT OF SPECIAL INSPECTION 1. GENERAL: REFER TO CHAPTER 17 OF THE 2022 CBC FOR AMPLIFICATION OF, AND/OR EXCEPTIONS TO, THE FOLLOWING REQUIREMENTS (E.G., WELDING, ETC.). ALL SPECIAL INSPECTORS MUST SUBMIT FINAL REPORTS. 2. INSPECTORS: ALL TESTS AND INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT INSPECTION AGENCY. JOB SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE, AND ARE NOT A SUBSTITUTE FOR, INSPECTIONS BY AN INDEPENDENT INSPECTION AGENCY. ALL TESTING AND I INSPECTION REPORTS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT. THE FINAL REPORT BY THE TESTING AND INSPECTION AGENCIES MUST CERTIFY THAT THE ENTIRE STRUCTURAL SYSTEM COMPLIES WITH THE APPROVED PLANS AND SPECIFICATIONS. SUBMIT ALL TEST & INSPECTION REPORTS TO ENGINEER OF RECORD. 3.NOTE: IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO SEE THAT THESE TEST AND INSPECTION ARE PERFORMED. A. WOOD NAILED 4" O.C. OR CLOSER B. EPOXY ANCHORS / ADHESIVE ANCHORS G.FOUNDATION DESIGN CRITERIA 1. THERE IS NO SOIL'S REPORT PREPARED FOR THIS PROJECT. USE THE WORST CONDITION AS PRESCRIBED ON CBC 2022 - TABLE R401.4.1 LOAD BEARING PRESSURE = 1,500 PSF a) Importance Factor, i = 1 b) Fa = 1.3; Fv =1.70 c) Ss = 2.4421 g, 0.2 sec response; S1 =0.9933 g, 1.0 sec response d) Site Class = D e) Sds = Sms *2_ 3 = 2.116; Sd1 = Sm1 *2_ 3 =1.126 f) Seismic Design Category = D g) Basic Seismic Force Resisting System= Wood Shear Wall; h) Cd = 4.0 i) R = 6.5 j) Omega = 3.0 k) hn = 11' (Mean Roof Height) Ta=0.112 n) Redundancy Factor = 1.3 o) Cs = 0.2505 p) Analysis Procedure Used = Per2020 LARC CBC;2019 LARC CBC; ASCE 7-16. A) ROOF DEAD LOAD = 10 PSF B)ROOF LIVE LOAD =20 PSF ROOF LOAD 1. CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE CITY INSPECTORS AND THE OWNER PRIOR TO THE COMMANCEMENT OF WORK ON SUCH SYSTEM OR SOMPONENT PER SEC. 1706.1 2. CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, CONCRETE STRENGTH F'C>2500PSI, ENGINEERED MASONRY, HIGH-LIFT GROUTING. 3. FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. (2304.11.2.4) 4. FIELD WELDING TO BE DONE BY WELDERS CERTIFIED BY THE CITY FOR (STRUCTURAL STEEL) (REINFORCING STEEL)(LIGHT GAUGE STEEL). CONTINUOUS INSPECTION BE A DEPUTY INSPECTOR IS REQUIRED. 5. SHOP WELDS MUST BE PERFORMED IN A LICENCED FABRICATOR'S SHOP. 6. LICENSED FABRICATOR IS REQUIRED FOR STRUCTURAL STEEL. 7.GLULAM BEAMS MUST BE FABRICATED IN A LICENSED SHOP. IDENTIFY GRADE SYMBOL AND LAMINATION SPECIES PER T 5-A, 2005 NDS SUPP. 8.PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR SHANK PORTION. 9.PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND 10.A COPY OF THE RESAERCH REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. 1.HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS; AND HOLD-DOWNS SHALL BE TIGHTENED JUST PRIOR TO CONVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE STEEL PLATE WASHERS IN ACCORDANCE WITH TABLE 2306.5 OF THE CITY/COUNTY BUILDING CODE. (2306.5) 2.ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.7 3.ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 4.ALL BOLT HOLES SHALL BE DRILLED 1/32 TO 1/16" OVERSIZED. (11.1.2.2, '05 5.HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 6.ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO THE SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.7 7.ALL DIAPHRAGMS AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 8. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. 1. ALL STRUCTURAL LUMBER SHALL BE GRADED IN ACCORDANCE WITH THE "GRADING AND DRESSING RULES(#16) OF THE WEST COAST LUMBERMAN'S ASSOCIATION". 2. ALL WOOD BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED DOUGLAS FIR OR CONSTRUCTION GRADE REDWOOD. 3. HOLES FOR BOLTS SHALL BE BORED WITH A BIT(1/32" TO 1/16") LARGER THAN THE NORMAL BOLT DIAMETER. ALL BOLTS SHALL BE RE-TIGHTENED PRIOR TO APPLICATION OF PLYWOOD, PLASTER, ETC. 4. STRUCTURAL MEMBERS SHALL NOT BE CUT FIR PIPES, ETC. UNLESS SPECIFICALLY NOTED OR DETAILED. 5. 2x SOLID BLOCKING SHALL BE PLACED BETWEEN JOISTS OR RAFTERS AT ALL SUPPORTS. 6. CROSS-BRIDGING SHALL BE PROVIDED AT (8'-0" 0/C) MAX. FOR ALL FLOOR JOISTS OVER (4") IN DEPTH AND ALL ROOF JOISTS OVER (6") IN DEPTH. USE 2x3 OR SOLID BLOCKING OR AN APPROVED TYPE METAL BRIDGING. 7. ALL STRUCTURAL PLYWOOD SHALL BE STRUCTURAL I OR II (C-D) GRADE WITH EXTERIOR GLUE AND CONFORM TO (PS-1-83). EACH SHEET SHALL BE IDENTIFIED BY A REGISTERED STAMP OR BRAND OF THE "TECO, D.F.P.A. OR PITTSBURGH TESTING LABORATORY". 8. ALL BOLTS BEARING ON WOOD SHALL HAVE STANDARD CUT WASHERS UNDER HEAD AND NUT, UNLESS NOTED OTHERWISE. 9. PROVIDE 1x6 DIAGONAL LET-IN BRACE AT APPROXIMATELY 45" EVERY (25'-0") IN ALL STUD WALLS NOT PLYWOOD SHEATHED. BRACING SHALL CONTINUE FROM TOP PLATES TO SILL PLATE OR USE SIMPSON CWB METAL WALL BRACES. 10. ALL JOIST HANGERS SHALL BE "SIMPSON" OR AN APPROVED EQUAL. 6 FIELD NAILING OVER 15" WIDE WALL OPENING SEE NOTE #4 STUD FULL HT. EDGE NAIL THRU (2) 2X TOP PLATE . LESS THAN OR EQUAL TO 7" .4' (N) FOOTING 3X6 BOT. PLATE E.N. ALL POST W/N WALL TYPICAL E.N. PERIMETER OF EACH PLYWOOD SHEET SEE PLAN AND SCHED. FOR PLYWD SIZE AND NAIL SPACING STAGGER PYWOOD PANELS E.N. AT ALL OPENINGS SEE NOTE #4 FOR OPENING LARGER THAN 15" MAX. OPN'G. SIZE 16" SQ ONE OPN'G. PER 8" OF WALL WITHOUT SPECIAL APPROVAL FROM BLDG INSPECTOR EDGE STUDS & BLK'G SEE NOTE #2 16" MINIMUM E.N. ALL POST W/N WALL,TYPICAL NOTES: 1.NAILS SHALL BE 1/2" MIN. EDGE DISTANCE FROM EDGE OF PLYWOOD AND EDGE OF STUD. USE COMMON NAILS ONLY. 2.USE 2X EDGE STUDS & BLK'G. WHERE NAIL SPACING IS LESS THAN 6" O.C. FOR 10d NAILS AND WHERE CALLED OUT IN PLANS AND DETAILS.USE 2X SILL PLATE AT SHEAR WALLS B,C,D AND E ONLY WHERE SILL PLATE RESTS ON CONCRETE. 3.PROVIDE 3/4" NAIL EDGE DISTANCE AT 3X STUDS AND BLK'G. 4.AT OPENING IN SHEAR PANEL OVER 15" WIDE,PROVIDE SOLID BLK'G AT HEAD AND SILL LEVEL, EACH SIDE OF OPENING STRAP WITH 1"X16 GA X 3 TIMES OPENING WIDTH GALV. METAL STRAP NAIL 8d @ 2" O.C. 5.NAILING WITH MACHINE NAILS SHALL CONFORM TO THE WOOD GENERAL NOTES. 6.ALL DEFECTIVE NAILS SHALL BE REMOVED AND REPLACED WITH SOUND NAILING 7.PLYWOOD SHEATHING SHALL BE PER SHEARWALL SCHEDULE BELOW U.N.O. PROVIDE FRAMING MEMEBER OR BLOCKING AT ALL EDGES PER SCHEDULE. PROVIDE EDGE NAILING TO END STUD OR POST WHERE HOLDOWN OCCURS AND TO ALL OTHER POSTS IN SHEARWALLS. 8.SILL PLATES SHALL BE PRESSURE TREATED D.F. AND CONFORM TO SILL PLATES DETAILS. PROVIDE MINIMUM OF 3 ANCHOR BOLTS IN ALL SHEAR WALLS. 9.WHERE PLYWOOD IS ON TWO SIDES OF WALL,THE SPACINGS OF ANCHOR BOLT AND AS35 SHOULD BE REDUCED TO HALF THE SPACING SHOWN ON THE TABLE. STAGGER NAILING AND JOINTS. 10.ALL SHEARWALLS NAILING,ANCHOR BOLT INSTALLATION,HOLDOWN INSTALLATION AND OTHER ELEMENTS OF SHEARWALL ASSEMBLY SHALL BE INSPECTED BY THE ENGINEER OF RECORD, A CERTIFICATE OF INSPECTION MUST BE SUBMITTED TO THE ENGINEER OF RECORD AND TO THE BUILDING DEPARTMENT.THE BUILDING OWNER SHALL BE RESPONSIBLE FOR THE THE INSPECTOR FOR PERFORMING THE STRUCTURAL OBSERVATION. 11.PLYWOOD SHEARWALLS SHALL BE COVERED WIHT 2 LAYERS OF 15# FELT UNDERLAYMENT PRIOR TO PLACING FINISH MATERIALS. 12.STAGGER NAILS IF NAIL SPACING IS LESS THAN 3" O/C 13.ANCHOR BOLTS - DESIGN INCLUDES REDUCED EDGE DISTANCE. DEPUTY INSPECTOR IS REQUIRED. SHEAR WALL SCHEDULE PANEL SHEATINGSIDES 15/32" STRUCT 1 PLYWOOD W/ 10d COMMON NAIL BLOCKED. SIDES 1 PANEL EDGE NAIL SPACING 6"-6" BLOCKING TO TOP PLATE/SILL A35/LTP @24" O.C. SILL/SOLE PLATES TO BLOCKING 3/8"Ø LAG-SCREW @ 11" O.C.; 5" MIN. EMBED. MUD SILL TO FOUNDATION 5/8" DIA. A.B. @ 36" O.C.; ALLOWABLE LOAD 340 plf 5/8" BOLT W/ WASHER 3" X 3" X 3/8" SPACED @ 36" O.C. W/ SIMP. STRONG-TIE SET ADHESIVE, SET PAC ST R U C T U R A L N O T E S PROPOSED ACCESSORY DWELLING UNIT NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 2121 N LEWIS ST. AND 2121 N LEWIS ST. #2 SANTA ANA, CA 92706 - 2236 LINH LE AND DAVID FREUDENBERGER 02-S0.1 NOTE: THIS PLAN AND DETAILS ARE APPLICABLE TO BOTH ADU MIRROR IMAGE PER PLAN ALL SHEETS. 6X 6 H D R 6X 1 2 H D R 6X6 HDR 15/32'' OSB W/ 8D SPACED @ 6''-6''-12'' 15/32'' OSB W/ 8D SPACED @ 6''-6''-12'' 2X12 RIDGE BOARD 2X8 @ 16'' O.C. R.R. 15/32'' OSB W/ 8D SPACED @ 6''-6''-12'' 2X 1 0 R I D G E BO A R D 6X6 HDR6X6 HDR 2X8 @ 16'' O.C. R.R. 6X6 HDR 6X6 HDR2X 8 @ 1 6 ' ' O. C . R . R . 6X 6 H D R 6X6 HDR 4X 6 H D R 4X6 HDR 2X 8 @ 1 6 ' ' O. C . R . R . 2X 8 @ 1 6 ' ' O. C . C . J . 2X 8 @ 1 6 ' ' O . C . R . R . 6X6 HDR 4X 6 H D R 6X6 HDR 2X 8 @ 1 6 ' ' O. C . R . R . 2X 8 @ 1 6 ' ' O. C . R . R . 2X 8 @ 1 6 ' ' O. C . R . R . 2X 8 @ 1 6 ' ' O. C . C . J . 2X 8 @ 1 6 ' ' O. C . C . J . 2X 8 @ 1 6 ' ' O. C . C . J . 2X 8 @ 1 6 ' ' O. C . R . R . 2X 8 @ 1 6 ' ' O. C . C . J . 2X 8 @ 1 6 ' ' O. C . R . R . 2X 8 @ 1 6 ' ' O . C . R . R . 2X 8 @ 1 6 ' ' O. C . R . R . 4X4 POS T 2X12 RIDGE BOARD PR O V I D E 2 X 8 R A F T E R T I E S AT E V E R Y R O O F R A F T E R 2X 8 @ 1 6 ' ' O . C . R . R . PR O V I D E 2 X 8 R A F T E R T I E S AT E V E R Y R O O F R A F T E R MSTA36 4X12 BEAM ALIGN RAFTER TO WALLALIGN RAFTER TO WALL MSTA36 3 02-S1.1 10 02-S3.1 10 02-S3.1 10 02-S3.1 9 02-S3.1 4X4POS T 15 02-S3.1 6 02-S3.1 15 02-S3.1 6 02-S3.1 15 02-S3.1 6 02-S3.1 6 02-S3.1 6 02-S3.1 6 02-S3.1 6 02-S3.1 6 02-S3.1 15 02-S3.1 3 02-S1.1 3 02-S1.1 4X 1 0 B E A M 2X 8 @ 1 6 ' ' O. C . C . J . 2X 8 @ 1 6 ' ' O. C . C . J . 2X 8 @ 1 6 ' ' O. C . C . J . 2X 8 @ 1 6 ' ' O. C . R . R . 2X 8 @ 1 6 ' ' O. C . C . J . 3.5x11.875 PSL E 2.0 2X8 @ 16'' O.C. R.R. 2X8 @ 16'' O.C. R.R. 2X 8 @ 1 6 ' ' O. C . C . J . 4 02-S1.1 2X 8 @ 1 6 ' ' O. C . R . R . MS T A 3 6 2X 8 @ 1 6 ' ' O. C . R . R . 2X8 @ 16'' O.C. R.R. 2X8 @ 16'' O.C. R.R. 2X8 @ 16'' O.C. C.J.2X8 @ 16'' O.C. C.J. 2X12 RIDGE BOARD 4X4 POS T 4X4POS T 4X4 POS T CALIFORIA FRAMING 30''W X 36''H SD WINDOW 4X6 HDR4X6 HDR 6X 1 2 H D R AB O V E 6X6 HDR ABOVE 4X 6 H D R AB O V E L=7' 6 L=5' 6 L=6' 6 L=9' 6 L= 6 ' 6 L= 6 ' 6 6 L=5' 6 L=6' L= 1 2 ' 6 4X6 HDR ABOVE 6X6 HDR ABOVE 6X6 HDR ABOVE 6X6 HDR ABOVE 6X6 HDR ABOVE 6X6 HDR ABOVE 6X6 HDR ABOVE 6X 6 H D R AB O V E 4X 6 H D R AB O V E 6X 6 H D R AB O V E 6X6 HDR ABOVE 4X6 HDR ABOVE 12''WIDE X 24''DEEP WALL FOOTING 12'' WIDE X 24'' DEEP WALL FOOTING PROVIDE HDU5 HOLDDOWN @ B.S. FOR EVERY SHEARWALL 6' OR LESS, TYPICAL. 12'' WIDE X 24'' DEEP WALL FOOTING PROVIDE HDU5 HOLDDOWN @ B.S. FOR EVERY SHEARWALL 6' OR LESS, TYPICAL. 12'' WIDE X 24'' DEEP WALL FOOTING 12'' WIDE X 24'' DEEP WALL FOOTING PROVIDE HDU5 HOLDDOWN @ B.S. FOR EVERY SHEARWALL 6' OR LESS, TYPICAL. NON-LOAD BEARING, NON-STRUCTURAL WALL NON-LOAD BEARING, NON-STRUCTURAL WALL NON-LOAD BEARING, NON-STRUCTURAL WALL PROVIDE HDU5 HOLDDOWN @ B.S. FOR EVERY SHEARWALL 6' OR LESS, YPICAL. 18'' WIDE X 24'' DEEP WALL FOOTING (N) 4'' THK. CONCRETE SLAB W/ # 4 REBARS @ 16'' O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. (N) 4'' THK. CONCRETE SLAB W/ # 4 REBARS @ 16'' O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. (N) 4'' THK. CONCRETE SLAB W/ # 4 REBARS @ 16'' O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 4X4 POS T 24''X24''X24'' PAD FOOTING 14 02-S3.1 4 02-S3.1 2 02-S3.1 1 02-S3.1 1 02-S3.1 4 02-S3.1 1 02-S3.1 4 02-S3.1 8 02-S3.1 8 02-S3.1 12 02-S3.1 12 02-S3.1 12 02-S3.1 12 02-S3.1 1 02-S3.1 4 02-S3.1 8 02-S3.1 L=4' L= 2 ' END BOLT: 2-1/2" FROM EDGE CENTER BOLT: 18-1/4" SPACING EXTERIOR FACE OFFSET 1-1/8" 12'' WIDE X 24'' DEEP WALL FOOTING WH S H WHSH SIMPSON STRONG WALL 4' WIDE X 6' LENGTH X 2' THK. SEE DETAILS ON SHEETS 02-S3.2 AND 02-S3.3 WH S H L= 2 ' L=4' WHSH SIMPSON STRONG WALL 4' WIDE X 6' LENGTH X 2' THK. SEE DETAILS ON SHEETS 02-S3.2 AND 02-S3.3 END BOLT: 2-1/2" FROM EDGE CENTER BOLT: 18-1/4" SPACING EXTERIOR FACE OFFSET 1-1/8" 1 02-S3.1 4 02-S3.1 1 02-S3.1 4 02-S3.1 6 6 4X4 POS T 4X4 POS T 4X4 POS T 4X4 POS T 4X6 HDR ABOVE 2X ROOF RAFTER 2X FLAT W/3-16d @EA. RAFTER 15/32" STRUCT 1 PLYWOOD CALIFORNIA FRAMING A35 16D @ 6" O.C. 2X DBL. BLOCKING W/ A35 @ EA. SIDE SIMPSON A35 @EA. ROOF RAFTER B.N TO BLK'G BELOW CONTINUOUS PLYWD 18" 3" CLEAR NAT. GRADE 15/32" OSB OR PLYWOOD STRUCT 1 W/ 8d SPACED @ 6"-6"-12" EACH BLOCK 2"x4" DOUBLE TOP PLATE 1/2" GYP. BOARD SHEAR WALL, WHERE OCCURS. FOR SHEAR SCHED. REFER TO SHEET 02-S0.1. 2"x4" P.T. SILL 5/8" DIA. x 9" LONG (MIN.) ANCHOR BOLT W/ 3x3x3/8" SQ. WASHER SPACED @ 36" O.C. 5/8" SQ. X 9" EMBED AB @ 36" O.C. MAX 2-#4 REINF. TOP AND BOTTOM #4 @16 O.C REINF. ALT BENDS 1'-6" BN/EN PER SCHEDULE FLAT A-35 OR LTP4's 4X BLOCKING BN/EN 2X8 RR 4'' THK. CONCRETE SLAB WITH #4 REBARS @16" O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. BN/EN 2X8 CJ SEE PLAN EACH BLOCK 2"x4" DOUBLE TOP PLATE FLAT A-35 OR LTP4'S BLOCKING BN/EN BN/EN 9' - 0 " 4" 24 " 3' - 7 " SHEAR WALL BLOCKING 10d @16" O.C. 2" x 4" STUD AT 16" O.C. 4" FL O O R F R A M I N G P L A N A N D RO O F R A M I N G P L A N SCALE ROOF FRAMING PLAN NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 1/4" = 1'-0" SCALE FOUNDATION PLAN 1/4" = 1'-0" S LEGEND: PROPOSED WALL FOOTING PROPOSED NON-BEARING WALL PROPOSED SHEARWALL PER SHEAR WALL SCHEDULE ON SHEET 3.0 PROPOSED SIMPSON WSWH PER SHEAR WALL SCHEDULE ON SHEETS 3.3 AND 3.4SS 02-S1.1 SPECIFICATIONS : HEADER, JOISTS, AND RAFTER DF#1 STUDS DF#2 CONCRETE 2,500 PSI STEEL 60,000 PSI SILL PLATE PRESSURE TREATED SCALE 3/4" = 1'-0" CALIFORNIA ROOF3 NOT TO SCALE SHEAR TRANSFER (INTERIOR WALL)4 NON-SHRINK GROUT #23616FIVE STAR GROUT HOLD-DOWNS SIMPSON HOLD-DOWNS #24818 #24947, #25076SIMPSON JOIST HANGERSJOIST HANGERS #22086SIMPSON FTA5 STRAPSTRAPS SET "XP" EPOXY #25279SIMPSON EPOXY ANCHOR LARR NUMBERS SEISMIC DESIGN CRITERIA a) Importance Factor, i = 1 b) Exposure = C c) Wind Velocity = 110 MPH WIND DESIGN CRITERIA C.REINFORCING STEEL 1.ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE, CONFORMING TO A.S.T.M.(A-615-40), U.N.O. 2.USE LOW HYDROGEN ELECTRODES, GRADE (E-70), FOR WELDING REINFORCING BARS. 3.REINFORCING BARS MARKED CONT. SHALL BE SPLICED WITH A MINIMUM LAP OF (40) BAR DIAMETERS IN MASONRY AND (36) DIAMETERS IN CONCRETE. 4.ALL REINFORCING SHALL BE SECURELY TIED AND BRACED IN PLACE PRIOR TO POURING CONCRETE OR PLACING MASONRY. 5.PROVIDE THE FOLLOWING MINIMUM PROTECTIVE COVERING OF CONCRETE OVER REINFORCING STEEL. BELOW GRADE (UNFORMED)----------------3" CLR. BELOW GRADE (FORMED)--------------------2" CLR. H.NAILING SCHEDULE COMMON WIRE NAILS 1.JOIST TO SILL OR GIRDER TOE NAIL---------------------------------------------------------------------------------------------3-8d 2.BRIDGING TO JOIST TOE NAIL EACH END--------------------------------------------------------------------------------------2-8d 3.1" BY 6" SUBFLOOR OR LESS TO EACH JOIST FACE NAIL----------------------------------------------------------------2-8d 4.WIDER THAN 1" BY 6" SUBFLOOR TO EACH JOIST FACE NAIL----------------------------------------------------------3-8d 5.2" SUBFLOOR TO JOIST OR GIRDER BLIND AND FACE NAIL-----------------------------------------------------------2-16d 6.SOLE PLATE TO JOIST OR BLOCKING FACE NAIL--------------------------------------------------------------16d @16" O/C 7.TOP PLATE TO STUD END NAIL---------------------------------------------------------------------------------------------------2-16d 8.STUD TO SOLE PLATE TOE NAIL---------------------------------------------------------------------------------------------------4-8d 9.DOUBLED STUDS FACE NAIL------------------------------------------------------------------------------------------16d @24" O/C 10.DOUBLED TOP PLATES FACE NAIL----------------------------------------------------------------------------------16d @16" O/C 11.TOP PLEATES, LAPS & INTERSECTIONS FACE NAIL----------------------------------------------------------------------2-16d 12.CONTINUOUS HEADER, TWO PIECES ALONG EACH SIDE--------------------------------------------------16d @16" O/C 13.CEILING JOISTS TO PLATE FACE NAIL-------------------------------------------------------------------------------------------3-8d 14.CONTINUOUS HEADER TO STUD TOE NAIL------------------------------------------------------------------------------------4-8d 15.CEILING JOISTS, LAPS OVER PARTITIONS FACE NAIL-------------------------------------------------------------------3-16d 16.CEILING JOISTS TO PARALLEL RAFTERS FACE NAILS-------------------------------------------------------------------3-16d 17.RAFTER TO PLATE TOE NAIL--------------------------------------------------------------------------------------------------------3-8d 18.1 BY BRACE TO EACH STUD AND PLATE FACE NAIL-----------------------------------------------------------------------2-8d 19.1 BY 8 SHEATING OR LESS TO EACH BEARING FACE NAIL--------------------------------------------------------------2-8d 20.WIDER THAN 1 BY 8 SHEATHING TO EACH BEARING FACE NAIL------------------------------------------------------3-8d 21.BUILT-UP CORNER STUDS----------------------------------------------------------------------------------------------16d @24" O/C 22.BUILT-UP GIRDER AND BEAMS: AT TOP & BOTTOM & STAGGERED--------------------------------------------------------------------------------20d @32" O/C AT ENDS & AT EACH SPLICE-----------------------------------------------------------------------------------------------------2-20d 23.2 BY PLANKS AT EACH BEARING-------------------------------------------------------------------------------------------------2-16d GENERAL NAILING NOTES 1.NAILS SHALL BE DRIVEN PERPENDICULAR WHERE POSSIBLE INSTEAD OF TOE NAILS. 2.PRE-DRILL FOR ALL NAILS 30d OR LARGER. 3.ALL NAILS SHALL BE COMMON WIRE NAILS UNLESS OTHERWISE NOTED. A.GENERAL NOTES 1.CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE CITY INSPECTORS AND THE OWNER PRIOR TO THE COMMANCEMENT OF WORK ON SUCH SYSTEM OR SOMPONENT PER SEC. 1706.1 2.CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, CONCRETE STRENGTH F'C>2500PSI, ENGINEERED MASONRY, HIGH-LIFT GROUTING. 3.FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. (2304.11.2.4) 4.FIELD WELDING TO BE DONE BY WELDERS CERTIFIED BY THE CITY FOR (STRUCTURAL STTEL)(REINFORDING STEEL)(LIGHT GAUGE STEEL). CONTINUOUS INSPECTION BE A DEPUTY INSPECTOR IS REQUIRED. 5.SHOP WELDS MUST BE PERFORMED IN A LICENCED FABRICATOR'S SHOP. 6.LICENSED FABRICATOR IS REQUIRED FOR STRUCTURAL STEEL. 7. GLULAM BEAMS MUST BE FABRICATED IN A LICENSED SHOP. IDENTIFY GRADE SYMBOL AND LAMINATION SPECIES PER T 5-A, 2005 NDS SUPP. 8. PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR SHANK PORTION 9. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND 10. A COPY OF THE RESERCH REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. D.SHEAR WALL (T2306.4.1) NDS) E.LUMBER / FRAMING 1.ALL STRUCTURAL LUMBER SHALL BE GRADED IN ACCORDANCE WITH THE "GRADING AND DRESSING RULES(#16) OF THE WEST COAST LUMBERMAN'S ASSOCIATION". 2.ALL WOOD BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED DOUGLAS FIR OR CONSTRUCTION GRADE REDWOOD. 3.HOLES FOR BOLTS SHALL BE BORED WITH A BIT(1/32" TO 1/16") LARGER THAN THE NORMAL BOLT DIAMETER. ALL BOLTS SHALL BE RE-TIGHTENED PRIOR TO APPLICATION OF PLYWOOD, PLASTER, ETC. 4.STRUCTURAL MEMBERS SHALL NOT BE CUT FIR PIPES, ETC. UNLESS SPECIFICALLY NOTED OR DETAILED. 5.2x SOLID BLOCKING SHALL BE PLACED BETWEEN JOISTS OR RAFTERS AT ALL SUPPORTS. 6.CROSS-BRIDGING SHALL BE PROVIDED AT (8'-0" 0/C) MAX. FOR ALL FLOOR JOISTS OVER (4") IN DEPTH AND ALL ROOF JOISTS OVER (6") IN DEPTH. USE 2x3 OR SOLID BLOCKING OR AN APPROVED TYPE METAL BRIDGING. 7.ALL STRUCTURAL PLYWOOD SHALL BE STRUCTURAL I OR II (C-D) GRADE WITH EXTERIOR GLUE AND CONFORM TO (PS-1-83). EACH SHEET SHALL BE IDENTIFIED BY A REGISTERED STAMP OR BRAND OF THE "TECO, D.F.P.A. OR PITTSBURGH TESTING LABORATORY". 8.ALL BOLTS BEARING ON WOOD SHALL HAVE STANDARD CUT WASHERS UNDER HEAD AND NUT, UNLESS NOTED OTHERWISE. 9.PROVIDE 1x6 DIAGONAL LET-IN BRACE AT APPROXIMATELY 45" EVERY (25'-0") IN ALL STUD WALLS NOT PLYWOOD SHEATHED. BRACING SHALL CONTINUE FROM TOP PLATES TO SILL PLATE OR USE SIMPSON CWB METAL WALL BRACES. 10.ALL JOIST HANGERS SHALL BE "SIMPSON" OR AN APPROVED EQUAL. 11.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR LARCH OF THE FOLLOWING GRADES UNLESS NOTED OTHERWISE: PLYWOOD PANELS--------------------------STRUCTURAL I OR II, CDX EXT. GLUE CONFORMING TO PS-1-83 PLATES, BLOCKING-------------------------------------------------------------------------------------------------CONST. -875fb BEAMS, STRINGERS (4x)-------------------------------------------------------------------------------------------------#1-1000fb POST & BEAMS (>4x)-------------------------------------------------------------------------------------SEL. STRUCT. -1600fb ROOF PLANKING & DECKING-------------------------------------------------------------------------------COM. DEX. -875fb JOISTS & PLANKING--------------------------------------------------------------------------------------------------------#2 -875fb RAFTERS ----------------------------------------------------------------------------------------------------------------------#2 -875fb BOARDS, SHEATHING & STRIPPING------------------------------------------------------------------------CONST. GRADE SILLS, PLATES, SLEEPERS, POSTS OR WOOD EMBEDDED IN CONCRETE SLAB WHICH IS IN CONTACT WITH EARTH--------CONST. GRADE, PRESSURE TREATED MISC. NAILING STRIPS & BLOCK EMBEDDED IN CONCRETE OR MASONRY------------------------------GRADE SPECIFIED ABOVE, TANK DIPPED IN SALT PERSERVATIVE 12.ALL BREAKS FOR VENTS, DUCTS, PLUMBING SHALL BE STRAPPED WITH 1 1/2 x 1/8 STEEL STRAPS WITH 4-16d NAILS EACH SIDE. 13.HEADER SIZE NOT SHOWN SHALL BE PER UBC STANDARDS AND 4x4 MIN. 14.PROVIDE HOLDDOWNS (FTA, HD, PA, VERT. MST, ETC.) W/ DBL OR 4x STUD WITH E.N. 15.HANGER FOR 2x JST SHALL BE SIMPSON "U", FOR 4x OR 6x PURLIN SHALL BE SIMPSON "HUTF", U.N.O. 16.DBL. JOIST SHALL BE NAILED TOGETHER WITH 16d @ 9" O.C., STAGGER, U.N.O. 17.TIE ROOF RAFTERS AT RIDGE W/ ST 2115 @ 4'-0" 0/C. 18.NOTCHING OF EXTERIOR AND BEARING / NONBEARING WALLS SHALL NOT EXCEED 25% / 40% RESPECTIVELY. BORED HOLES IN BEARING / NONBEARING WALLS SHALL NOT EXCEED 40% / 60% RESPECTIVELY. 19.PLYWOOD ROOF PANELS SHALL BE BONDED WITH INTERMEDIATE OR EXTERIOR GLUE AND BE OF EXTERIOR TYPE WHERE EXPOSED TO THE WEATHER. 20.DOUBLE JOISTS ARE REQUIRED UNDER PARALLEL BEARING PARTITIONS. U.N.O. 21.THE REQUIRED CLEARANCE FOR WOOD MEMBERS ABOVE GRADE, IS 6" FOR MUDSILLS, 12" FOR GIRDERS, AND 18" FOR JOISTS. 22.ROOF DIAPHRAGM SHALL BE 1/2" PLYWOOD, PANEL INDEX 24/0, NAIL 8d @ 6", 12". FLOOR DIAPHRAGM SHALL BE 5/8" PLYWOOD, PANEL INDEX 32/16, T&G, NAIL 10d @ 6", 10", U.N.O. 23.LAY PLYWOOD PANEL STAGGERED W/ FACE GRAIN PERPENDICULAR TO SUPPORTS. 24.ALL DOUBLE TOP PLATES ARE TO BE CONTINUOUS BY NAILING OR STRAPS. SPLICE @4'-0"MIN. W/12-6d NAILS EACH SIDE OF SPLICE WHERE INTERRUPTED, TIE TOP PLT'S W/ SIMPSON MST 37, U.N.O. 25.ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIP GALVANIZED AFTER FABRICATION. 26.EACH SHEET OF PLYWOOD SHALL CONTAIN A MINIMUM OF (8) SQ. FT. AND SHALL EXTEND TO (3) BEARINGS MINIMUM WITH FACE-GRAIN PERPENDICULAR TO JOISTS. 27.PROVIDE EDGE NAILING OVER ALL WALLS, LAMINATED BEAMS, STRUTS AND ALL AROUND OPENINGS. 28.PROVIDE BOUNDARY NAILING AT PERIMETER OF BUILDING AND AT ALL CONTINUOUS PLYWOOD EDGES. 29.PROVIDE FULL BEARING ON ALL BEAMS AND JOISTS HANGERS; IF EXCESSIVE SHRINKAGE OCCURS, PROVIDE HANDWARE SHIMS, WHICH SHALL BE SECURED TO JOISTS. B.CONCRETE 1.ALL CONCRETE SHALL CONFORM TO THE 2022 CALIFORNIA RESIDENTIAL CODE AND CBC. 2.CONCRETE SHALL BE DESIGNED AND TESTED AS OUTLINED IN THE SPECS. 3.ALL CEMENT SHALL CONFORM TO A.S.T.M. (C-150), TYPE I OR II 4.FINE AND COARSE AGGREGATE SHALL CONFORM TO A.S.T.M. (C-33) FOR STANDARD WEIGHT CONCRETE AND A.S.T.M. (C-330) FOR LIGHT WEIGHT CONCRETE. 5.ALL AGGREGATE SHALL BE COMPARABLE TO "SAN GABRIEL VALLEY" AGGREGATE. THE SHRINKAGE SHALL BE PER A.S.T.M. (C-157) WITH THE AVERAGE DRYING SHRINKAGE AT (28 DAYS) OF DRYING NOT EXCEEDING (0.04%) 6.DRYPACK SHALL BE COMPOSED OF ONE PART PORTLAND CEMENT TO NOT MORE THAN THREE PARTS SAND. 7.ANCHOR BOLTS, DOWELS, INSERTS, ETC. SHALL BE SECURELY TIED IN PLACE PRIOR TO POURING CEMENT. 8.LOCATION OF CONSTRUCTION JOINTS OR POUR JOINTS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO POURING CONCRETE. 9.CONCRETE SHALL BE CURED BY KEEPING CONTINUOUSLY WET FOR (10 DAYS) OR BY AN APPROVED CURING COMPOUND. 10.REFER TO ARCHITECTUAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR MISCELLANEOUS ITEMS TO BE CAST INTO CONCRETE AND FLOOR DEPRESSIONS, ETC. 11.SEE ARCHITECTUAL DRAWINGS FOR LOCATION OF EXPANSION JOINTS, SCORING, ETC. FOR CONCRETE WALKS AND SLABS. 12.FOOTING AND GRADE BEAM SHALL BE F'c=2,500 PSI AT 28 DAYS. 12.ALL CONCRETE STRUCTURES SHALL HAVE A MINIMUM COMPRESSION STRENGTH OF F'c = 3,000 PSI AT 28 DAYS, UNLESS NOTED OTHERWISE. 13.PROVIDE INTERIOR SLAB CONTROL JOINTS AT MAXIMUM 20FT. O.C. EACH WAY. 14.NO WOOD OR STEEL STAKES SHALL BE PERMITTED TO BE LEFT IN FOOTINGS. 15.BOT. OF FTG. SHALL BE 18" MIN. FOR 1-STORY BLDG., 24" MIN. FOR 2-STORY BLDG., 24" MIN. FOR 3-STORY BLDG. OR EXPANSIVE SOIL BELOW NATURAL GRADE, U.N.O. 16.ALL PADS SHALL BE 14" THICK MIN. W/ #4 @ 12" E.W. AR BOT., U.N.O. F. STATEMENT OF SPECIAL INSPECTION 1. GENERAL: REFER TO CHAPTER 17 OF THE 2022 CBC FOR AMPLIFICATION OF, AND/OR EXCEPTIONS TO, THE FOLLOWING REQUIREMENTS (E.G., WELDING, ETC.). ALL SPECIAL INSPECTORS MUST SUBMIT FINAL REPORTS. 2. INSPECTORS: ALL TESTS AND INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT INSPECTION AGENCY. JOB SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE, AND ARE NOT A SUBSTITUTE FOR, INSPECTIONS BY AN INDEPENDENT INSPECTION AGENCY. ALL TESTING AND I INSPECTION REPORTS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT. THE FINAL REPORT BY THE TESTING AND INSPECTION AGENCIES MUST CERTIFY THAT THE ENTIRE STRUCTURAL SYSTEM COMPLIES WITH THE APPROVED PLANS AND SPECIFICATIONS. SUBMIT ALL TEST & INSPECTION REPORTS TO ENGINEER OF RECORD. 3.NOTE: IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO SEE THAT THESE TEST AND INSPECTION ARE PERFORMED. A. WOOD NAILED 4" O.C. OR CLOSER B. EPOXY ANCHORS / ADHESIVE ANCHORS G.FOUNDATION DESIGN CRITERIA 1. THERE IS NO SOIL'S REPORT PREPARED FOR THIS PROJECT. USE THE WORST CONDITION AS PRESCRIBED ON CBC 2022 - TABLE R401.4.1 LOAD BEARING PRESSURE = 1,500 PSF a) Importance Factor, i = 1 b) Fa = 1.3; Fv =1.70 c) Ss = 2.4421 g, 0.2 sec response; S1 =0.9933 g, 1.0 sec response d) Site Class = D e) Sds = Sms *2_ 3 = 2.116; Sd1 = Sm1 *2_ 3 =1.126 f) Seismic Design Category = D g) Basic Seismic Force Resisting System= Wood Shear Wall; h) Cd = 4.0 i) R = 6.5 j) Omega = 3.0 k) hn = 11' (Mean Roof Height) Ta=0.112 n) Redundancy Factor = 1.3 o) Cs = 0.2505 p) Analysis Procedure Used = Per2020 LARC CBC;2019 LARC CBC; ASCE 7-16. 1. HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS;AND HOLD-DOWNS SHALL BE TIGHTENED JUST PRIOR TO CONVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE STEEL PLATE WASHERS IN ACCORDANCE WITH TABLE 2306.5 OF THE CITY/COUNTY BUILDING CODE. (2306.5) 2. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.7 3. ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 4. ALL BOLT HOLES SHALL BE DRILLED 1/32 TO 1/16" OVERSIZED. (11.1.2.2, '05 5. HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 6. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO THE SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.7 7. ALL DIAPHRAGMS AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 8. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. SHEAR WALL SCHEDULE PANEL NAILINGTYPE DESCRIPTION OF SHEAR WALL MATERIAL 15/32" PLYWD. STRUCTURAL 1 PERIMETER FIELD 10D @ 4"O.C. BLKG. TO PLATE CONNECTION REQUIREMENT A35 @16" O.C. OR LPT4 @16"O.C. PLATE TO BLKG. CONNECT. . SDS 1/4"x6 @16" O.C. ANCHOR BOLTS SILL PLATE TO FOUND CONN. 5/8"Ø @32"O.C. ANCHOR BOLTS EMB. ALLOWABLE SHEAR LOAD PLF 280 PLF (4''-12'') 185 PLF (6''-12'') S 10D @ 12"O.C. FIELD NAILING OVER 15" WIDE WALL OPEING SEE NOTE #4 STUD FULL HT. EDGE NAIL THRU (2) 2X TOP PLATE . LESS THAN OR EQUAL TO 7" .4' (N) FOOTING 3X6 BOT. PLATE NOTES: 1. NAILS SHALL BE 1/2" MIN. EDGE DISTANCE FROM EDGE OF PLYWOOD AND EDGE OF STUD. USE COMMON NAILS ONLY. 2. USE 2X EDGE STUDS & BLK'G. WHERE NAIL SPACING IS LESS THAN 6" O.C. FOR 10d NAILS AND WHERE CALLED OUT IN PLANS AND DETAILS.USE 2X SILL PLATE AT SHEAR WALLS B,C,D AND E ONLY WHERE SILL PLATE RESTS ON CONCRETE. 3. PROVIDE 3/4" NAIL EDGE DISTANCE AT 3X STUDS AND BLK'G. 4. AT OPENING IN SHEAR PANEL OVER 15" WIDE,PROVIDE SOLID BLK'G AT HEAD AND SILL LEVEL,EACH SIDE OF OPENING STRAP WITH 1"X16 GA X 3 TIMES OPENING WIDTH GALV. METAL STRAP NAIL 8d @ 2" O.C. 5. NAILING WITH MACHINE NAILS SHALL CONFORM TO THE WOOD GENERAL NOTES. 6. ALL DEFECTIVE NAILS SHALL BE REMOVED AND REPLACED WITH SOUND NAILING 7. PLYWOOD SHEATHING SHALL BE PER SHEARWALL SCHEDULE BELOW U.N.O. PROVIDE FRAMING MEMEBER OR BLOCKING AT ALL EDGES PER SCHEDULE. PROVIDE EDGE NAILING TO END STUD OR POST WHERE HOLDOWN OCCURS AND TO ALL OTHER POSTS IN SHEARWALLS. 8. SILL PLATES SHALL BE PRESSURE TREATED D.F. AND CONFORM TO SILL PLATES DETAILS. PROVIDE MINIMUM OF 3 ANCHOR BOLTS IN ALL SHEAR WALLS. 9. WHERE PLYWOOD IS ON TWO SIDES OF WALL,THE SPACINGS OF ANCHOR BOLT AND AS35 SHOULD BE REDUCED TO HALF THE SPACING SHOWN ON THE TABLE. STAGGER NAILING AND JOINTS. 10. ALL SHEARWALLS NAILING,ANCHOR BOLT INSTALLATION,HOLDOWN INSTALLATION AND OTHER ELEMENTS OF SHEARWALL ASSEMBLY SHALL BE INSPECTED BY THE ENGINEER OF RECORD, A CERTIFICATE OF INSPECTION MUST BE SUBMITTED TO THE ENGINEER OF RECORD AND TO THE BUILDING DEPARTMENT.THE BUILDING OWNER SHALL BE RESPONSIBLE FOR THE THE INSPECTOR FOR PERFORMING THE STRUCTURAL OBSERVATION. 11. PLYWOOD SHEARWALLS SHALL BE COVERED WIHT 2 LAYERS OF 15# FELT UNDERLAYMENT PRIOR TO PLACING FINISH MATERIALS. 12. STAGGER NAILS IF NAIL SPACING IS LESS THAN 3" O/C 13. ANCHOR BOLTS - DESIGN INCLUDES REDUCED EDGE DISTANCE. DEPUTY INSPECTOR IS REQUIRED. E.N. ALL POST W/N WALL TYPICAL E.N. PERIMETER OF EACH PLYWOOD SHEET SEE PLAN AND SCHED. FOR PLYWD SIZE AND NAIL SPACING STAGGER PYWOOD PANELS E.N. AT ALL OPENINGS SEE NOTE #4 FOR OPENING LARGER THAN 15" MAX. OPN'G. SIZE 16" SQ ONE OPN'G. PER 8" OF WALL WITHOUT SPECIAL APPROVAL FROM BLDG INSPECTOR EDGE STUDS & BLK'G SEE NOTE #2 5/8" BOLT W/ WASHER 3" X 3" X 3/8" SPACED @ 32" O.C. W/ SIMP. STRONG-TIE SET ADHESIVE, SET PAC 16" MINIMUM E.N. ALL POST W/N WALL,TYPICAL 9'' FOR CAST-IN-PLACE CONCRETE. 6'' WITH SIMP'S SET XP EPOXY POST INSTALLED ANCHORS ST R U C T U R A L N O T E S PROPOSED ACCESSORY DWELLING UNIT NOTE: THIS PLAN AND DETAILS ARE APPLICABLE TO BOTH ADU MIRROR IMAGE PER PLAN ALL SHEETS. NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 2121 N LEWIS ST. AND 2121 N LEWIS ST. #2 SANTA ANA, CA 92706 - 2236 LINH LE AND DAVID FREUDENBERGER 02-S-3.0 21'-2" 51'-1" 10'-7" 26 26 13 ' - 1 " 10'-7" 24 ' - 4 " 28 4X 8 H D R 4X 8 H D R 4X 8 H D R 4X 8 H D R 4X 8 H D R 4X 8 H D R 4X8 HDR 4X 8 H D R 4X8 HDR 4X8 HDR 4X8 HDR 4X8 HDR 4X8 HDR4X8 HDR 4X10 HDR 4X8 HDR 4X4 POS T 4X4 POS T 4X4 POS T 4X4 KP 4X4 POS T 4X4 POS T 4X4 POS T 4X4 POS T 4X4 POS T 4X4POS T 4X4POS T 4X4POS T 4X4POS T 4X4POS T 4X4 POS T 15/32'' OSB W/ 8D SPACED @ 6''-6''-12'' 4X10 HDR 15/32'' OSB W/ 8D SPACED @ 6''-6''-12'' 2X 1 0 @ 2 4 ' ' O. C . R . R . 2X 1 0 @ 2 4 ' ' O. C . C . J . 2X 1 0 @ 2 4 ' ' O. C . R . R . 2X 1 0 @ 2 4 ' ' O. C . C . J . 2X 1 0 @ 2 4 ' ' O. C . R . R . 2X 1 0 @ 2 4 ' ' O. C . C . J . 2X 1 0 @ 2 4 ' ' O. C . R . R . 2X 1 0 @ 2 4 ' ' O. C . C . J . 2X 1 0 @ 2 4 ' ' O. C . R . R . 2X 1 0 @ 2 4 ' ' O. C . C . J . 2X 1 0 @ 2 4 ' ' O. C . R . R . 2X 1 0 @ 2 4 ' ' O. C . C . J . 4X4 POS T 2X 1 0 @ 2 4 ' ' O. C . R . R . 2X 1 0 @ 2 4 ' ' O. C . C . J . 2X 1 0 @ 2 4 ' ' O. C . R . R . 2X 1 0 @ 2 4 ' ' O. C . C . J . 29'-11" 4X4POS T 2X12 RB 2X12 RB 2X12 RB 2X12 RB 2X1 2 H I P 2X1 2 V A L L E Y 2X1 2 H I P 3.5X11.875 PSL E2.0 4X 1 2 B E A M 2X1 2 H I P 3.5X11.875 PSL E2.0 2X 1 0 @ 2 4 ' ' O. C . R . R . 2X 1 0 @ 2 4 ' ' O. C . C . J . 2X 1 0 @ 2 4 ' ' O . C . R . R . 2X 1 0 @ 2 4 ' ' O. C . C . J . 2X10 @ 24'' O.C. R.R. 2X10 @ 24'' O.C. R.R. 2X10 @ 24'' O.C. R.R. 2X10 @ 24'' O.C. C.J. 2X10 @ 24'' O.C. R.R. 15/32'' OSB W/ 8D SPACED @ 6''-6''-12'' 15/32'' OSB W/ 8D SPACED @ 6''-6''-12'' 2X 1 0 @ 2 4 ' ' O. C . R . R . 7'-6"7'-6"7'-6"7'-5" 3. 5 X 1 1 . 8 7 5 P S L E 2 . 0 3. 5 X 1 1 . 8 7 5 P S L E 2 . 0 3. 5 X 1 1 . 8 7 5 P S L E 2 . 0 22 ' - 4 " 10 ' 29'-9" 49'-1" 19'-2" 10 ' 4X 8 H D R AB O V E 4X 8 H D R AB O V E 4X 8 H D R AB O V E 4X 8 H D R AB O V E 4X 8 H D R AB O V E 4X 8 H D R AB O V E 4X8 HDR ABOVE 4X 8 H D R AB O V E 4X8 HDR ABOVE 4X8 HDR ABOVE 4X8 HDR ABOVE 4X10 HDR ABOVE 4X8 HDR ABOVE 4X8 HDR ABOVE 4X8 HDR ABOVE 4X10 HDR ABOVE 4X8 HDR ABOVE L=4' S L=2' S L=5' S S L= 1 0 ' SS L=4' S L=11' S L=5' S L=6' S L= 1 0 ' L=10' S L=8' S SS L= 2 ' L=6' S L=9' S SL= 5 ' 4X4 POS T 4X4 POS T 4X4 POS T 4X4 POS T 4X4 POS T 4X4 KP 4X4 POS T 4X4 POS T 4X4 POS T 4X4POS T 4X4 POS T 4X4 POS T 4X4POS T 4X4POS T 4X4POS T 4X4POS T 4'' THK. CONCRETE SLAB W/ #4 REBARS @ 16'' O.C.E.W.; OVER 4'' OF 1/2'' CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 4'' THK. CONCRETE SLAB W/ #4 REBARS @ 16'' O.C.E.W.; OVER 4'' OF 1/2'' CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 4'' THK. CONCRETE SLAB W/ #4 REBARS @ 16'' O.C.E.W.; OVER 4'' OF 1/2'' CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 18'' WIDE X 24''DEEP WALL FOOTING 18'' WIDE X 24''DEEP WALL FOOTING 12''WIDE X 24''DEEP WALL FOOTING PROVIDE HD5B HOLDDOWN @ B.S. FOR EVERY SHEARWALL 6' OR LESS, TYPICAL. 12''WIDE X 24''DEEP WALL FOOTING 12''WIDE X 24''DEEP WALL FOOTING PROVIDE HD5B HOLDDOWN @ B.S. FOR EVERY SHEARWALL 6' OR LESS, TYPICAL. 12''WIDE X 24''DEEP WALL FOOTING PROVIDE HD5B HOLDDOWN @ B.S. FOR EVERY SHEARWALL 6' OR LESS, TYPICAL. 12''WIDE X 24''DEEP WALL FOOTING 12''WIDE X 24''DEEP WALL FOOTING 12''WIDE X 24''DEEP WALL FOOTING 18'' WIDE X 24''DEEP WALL FOOTING NON-LOAD BEARING, NON- STRUCTURAL WALL PROVIDE HD5B HOLDDOWN @ B.S. FOR EVERY SHEARWALL 6' OR LESS, TYPICAL. 12''WIDE X 24''DEEP WALL FOOTING NON-LOAD BEARING, NON-STRUCTURAL WALL PROVIDE HD5B HOLDDOWN @ B.S. FOR EVERY SHEARWALL 6' OR LESS, TYPICAL. 19'-5" 4' X 3' X 2' FOOTING AT SIMPSON STRONG WALL FL O O R F R A M I N G P L A N A N D RO O F R A M I N G P L A N SCALE A LA NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 SCALE 1/4" = 1'-0" 2 SCALE 1/4" = 1'-0"3.1 L A LA1 SCALE 1/4" = 1'-0" S LEGEND: PROPOSED WALL FOOTING PROPOSED NON-BEARING WALL PROPOSED SHEARWALL PER SHEAR WALL SCHEDULE ON SHEET 3.0 PROPOSED SIMPSON WSWH PER SHEAR WALL SCHEDULE ON SHEETS 3.3 AND 3.4SS3.1 02-S-3.1 WOOD POST SEE PLAN. BEAM PER PLANSIMPSON "ECC" COLUMN CAP, (U.O.N.), SEE PLAN. WALLS WITH OPENINGS 4'-0" AND ALL INTERIOR OPENINGS WIDER THAN EXTERIOR WALLS WITH PROVIDE SIMPSON 'A-35' 2X CRIPPLES @ 16" O/C (1) STUD @ INTERIOR WALLS, (2) STUDS @ EXTERIOR WALLS 16d @ 12"O/C FIRE BLK'G. AT CEILING (8'-0" MAX.) ANGLE CLIP TOP & BOTTOM AT DOUBLE STUDS 4X HEADER PER PLAN 2-2X STUDS OR 4X WIDER THAN 8'-0" ANGLE CLIPS AT ALL 3-16d TO HEADER SPLICE AS REQ'D. 2-2X PLATES (N) BEAM PER PLAN (N) 4X4 KING POST SIMO. "CC" COLUMN CAP INVERTED SIMP. "CC" COLUMN CAP DETAIL A (N) 4X4 KING POST FROM 1ST FLOOR. SIMO. "CC" COLUMN CAP DETAIL B BEAM PER PLAN BEAM PER PLAN D 2X BLKG @ CEILING 12d TOENAIL 2X CONT. (2)16d D+2" FLOOR OR ROOF 2X F.J. OR R.R. D STUD AT SLOPING JOIST (2)16d EA. STUD 2X BLKG @ CEILING 10d TOENAILS D+2" FLOOR OR ROOF #4 @ 16" O.C.E.W. 4" THK. SLAB E.N. TREATED SILL (N) SLAB ON GRADE #4 @ 16"O.C.1' 2' 24 ' ' M I N . TWO-LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. DIRECTION OF SURFACE WATER DRAINAGE (TYP) 26 G.A. WEEP SCREED 4'' FROM DIRT AND 2'' TO PAVED. 2 - #4 CONTINUOUS BARS AT TOP AND BOTTOM POLYETHYLENE VAPOR BARRIER EXTENDED UNDER GRADE BEAM WHERE IT ALSO ACTS AS A CAPILLARY BREAK #5 CONT. NOTE: 1.F'c= 2, 500 PSI 2.Fy= 60, 000 PSI AS PER PLAN (N) 4'' THK. CONCRETE SLAB W/ # 4 REBARS @ 16'' O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 4" CO V E R , TY P . 24 " MI N I M U M 8" MI N . FFL BEAM OR JOIST BLKNG. TOP PLATE 2X4 WALL STUD @ 16'' O.C. FROM 1ST FLOOR UP TO 2ND FLOOR TOP PLACE. 16" O.C. 2-2X STUDS SIMPSON A35 @ OPPOSITE CORNERS MULTI STUDS 4X POST OR 2X STUD @ 4-SIMPSON H2.5 ANCHORS AT POST 2-2X TOP PLATES TOP, TYP. RIDGE BOARD PER BEAM 2X RAFTER PER PLAN 2XBLOCKING 2XNAILER 2X SOLID BLOCKING MSTA 36 (N) 4'' THK. CONCRETE SLAB W/ # 4 REBARS @ 16'' O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 1/2" SEL. STRUCT PLYWOOD AT SHEAR WALL, PER PLAN 8d @ 4" O.C. EDGE NAILING UNLESS OTHERWISE STATED ON PLAN. AS 35 @ 16" O.C. 2X C-JOIST D.F. GR. 1 2X6 STUD WALL @ 16" O.C. 8d @ 4" O.C. UNLESS OTHERWISE STATED ON PLAN REFER TO UBC NAILING SCH. FOR OTHER NAILING NOT SHOW HERE ON PLAN 15/32" STRUCT. 1 PLY NAILING PER PLAN 2X RAFTER D.F. GR. 1 PROVIDE A WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM OF 4" ABOVE GADE 24 " MI N I M U M 8d @ 6" O.C. BOUNDARY NAILING UNLESS OTHERWISE STATED ON PLAN 4" 6" MI N 4" "3/8" THK. CDX EXTERIOR PLYWOOD. (MATCH EXISTING EXTERIOR FINISH) "7/8" THK. EXTERIOR PLASTER OVER MIN. 15# BUILDNG PAPER OVER BUILDING PAPER OVER METAL LATH PROVIDE R-13 MINIMUM WALL INSULATION, UNLESS NOTED ON TITLE 24 CALCULATIONS GALVANIZED IRON SILL PLATE, TYPICAL AT GROUND LEVEL #4 @ 16" O.C. E.W. 4" THK. SLAB AS PER PLAN POLYETHYLENE VAPOR BARRIER EXTENDED UNDER GRADE BEAM WHERE IT ALSO ACTS AS A CAPILLARY BREAK NOTE: 1.F'c= 2, 500 PSI 2.Fy= 60, 000 PSI CONCRETE GRADE BEAM WITH 2-#4 CONTINUOUS BARS (N) 4'' THK. CONCRETE SLAB W/ # 4 REBARS @ 16'' O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 24 " MI N I M U M C OF RIDGEL SIMPSON MSTI 36 @ 4'-0" O.C. RAFTER AS SIMPSON "HUS" JOIST HANGER PLYWD. SHEATHINGPLYWD. SHEATHING RAFTER AS RIDGE BOARD 1'-0" 5-16d NAILS 2X SOLID BLOCKING. BDRY NAILS 2X ROOF RAFTERS PER PLAN PLYWOOD SHEATHING PER PLAN SIMP. A35 @ 16" 0.C., TYP. 1/2" THK. GYP. BD. ON 2X CEILING JOIST WALL INSUL. R-19 PER T24 1/2" THK. GYPSUM ON 2X6 STUDS @ 24" O.C. TYP. ROOF INSULATION R-38 PER T24 NOTE: HIGH PERFORMANCE ROOF PER 24 1-LAYER OF 5/8" THK. TYPE "X" GYPSUM BOARD 1-HR FIRE RATED, (AS NEEDED, PER PLAN) PER CRC TABLE R302.1(1). SEE SHT 01-A-230. 2X K.D. FASCIA BOARD CONT. G.I. TRIM 2-2X TOP PLATE 16D TOE NAILS @6" O.C. PLYWOOD SHEATHING (SHEAR WALL) PER PLAN STUCCO (MOISTURE PROTECTION)NAT. GRADE 5/8" SQ. X 9" EMBED AB @ 36" O.C. MAX 2-#4 BARS TOP AND BOTTOM #4 @16 O.C REINF. ALT BENDS 4'' THK. CONCRETE SLAB WITH #4 REBARS @16" O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 4" 4" 24 " 18" 3" CL E A R 4X STUD CONC. FOOTING (WALL FOOTING) 2- 3/4" Ø A.B. 2-1/2" EMBEDMENT IN WOOD 5 8 Ø BOLTS; 9" MIN. EMBEDMENT. SIMPSON'S HDU5 2X PLATE 1" ABOVE SILL (USE 4X4 MINIMUM STUD/POST WHERE HOLDDOWNS ARE) NOTE: 1.REFER TO MANUFACTURER'S STANDARD FOR MATERIALS AND INSTALLATIONS . 2.DEPUTY INSPECTION REQUIRED FOR EPOXY ANCHOR INSTALLATION. 4X4 POST SIMP. BASE CAP CONCRETE FOOTING 4-#4 EACH WAY TOP & BOTTOM SOG 3" 0' - 8 " 2' - 0 " MI N 2'-0" SEE PLAN SCALE 3/4" = 1'-0" HEADER6 SCALE 3/4" = 1'-0" KING POST5 SCALE 3/4" = 1'-0" INTERIOR FOOTING ST R U C T U R A L D E T A I L S EXTERIOR FOOTING SCALE 1 1" = 1'-0" SCALE 1" = 1'-0" BALLOON FRAMING11 2 SCALE 3/4" = 1'-0" KING POST SCALE 1/4" = 1'-0" LOAD PATH DETAIL13 NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 SCALE 1 1/2" = 1'-0" NO-BEARING WALL8 SLAB-ON-GRADE SCALE 3 1" = 1'-0" WEEP SCREED SCALE 4 1" = 1'-0" SCALE 1 1/2" = 1'-0" TYPICAL ROOF EAVES15 HOLD DOWN SCALE 12 3/4" = 1'-0" SCALE 1 1/2" = 1'-0" RIDGE10 SCALE 1" = 1'-0" BEAM-POST 02-S3.1 3/4" = 1'-0" PAD FOOTING14 SCALE ST R U C T U R A L D E T A I L S NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 02-S3.2 WOOD POST SEE PLAN. BEAM PER PLANSIMPSON "ECC" COLUMN CAP, (U.O.N.), SEE PLAN. WALLS WITH OPENINGS 4'-0" AND ALL INTERIOR OPENINGS WIDER THAN EXTERIOR WALLS WITH PROVIDE SIMPSON 'A-35' 2X CRIPPLES @ 16" O/C (1) STUD @ INTERIOR WALLS, (2) STUDS @ EXTERIOR WALLS 16d @ 12"O/C FIRE BLK'G. AT CEILING (8'-0" MAX.) ANGLE CLIP TOP & BOTTOM AT DOUBLE STUDS 4X HEADER PER PLAN 2-2X STUDS OR 4X WIDER THAN 8'-0" ANGLE CLIPS AT ALL 3-16d TO HEADER SPLICE AS REQ'D. 2-2X PLATES (N) BEAM PER PLAN (N) 4X4 KING POST SIMO. "CC" COLUMN CAP INVERTED SIMP. "CC" COLUMN CAP DETAIL A (N) 4X4 KING POST FROM 1ST FLOOR. SIMO. "CC" COLUMN CAP DETAIL B BEAM PER PLAN BEAM PER PLAN D 2X BLKG @ CEILING 12d TOENAIL 2X CONT. (2)16d D+2" FLOOR OR ROOF 2X F.J. OR R.R. D STUD AT SLOPING JOIST (2)16d EA. STUD 2X BLKG @ CEILING 10d TOENAILS D+2" FLOOR OR ROOF PER PLAN 4X4 POST SIMP. BASE CAP CONC. FOOTING8 24 ' ' M I N . 4-#4 EA WAY T&B SOG AS PER PLAN #4 @ 16" O.C.E.W. 4" THK. SLAB 24 " MI N I M U M 4" C O V E R TY P . E.N. TREATED SILL (N) SLAB ON GRADE 8" MI N . #4 @ 16"O.C.1' 2' 24 ' ' M I N . TWO-LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. DIRECTION OF SURFACE WATER DRAINAGE (TYP) 26 G.A. WEEP SCREED 4'' FROM DIRT AND 2'' TO PAVED. (N) 4'' THK. CONCRETE SLAB W/ # 4 REBARS @ 16'' O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 2-#4 CONTINUOUS BARS AT TOP AND BOTTOM POLYETHYLENE VAPOR BARRIER EXTENDED UNDER GRADE BEAM WHERE IT ALSO ACTS AS A CAPILLARY BREAK #5 CONT. NOTE: 1.F'c= 2, 500 PSI 2.Fy= 60, 000 PSI FFL 2X4 WALL STUD @ 16'' O.C. FROM 1ST FLOOR UP TO 2ND FLOOR TOP PLACE. BEAM OR JOIST BLKNG. TOP PLATE 16" O.C. 2-2X STUDS SIMPSON A35 @ OPPOSITE CORNERS MULTI STUDS 4X POST OR 2X STUD @ 4-SIMPSON H2.5 ANCHORS AT POST 2-2X TOP PLATES TOP, TYP. RIDGE BOARD PER BEAM 2X RAFTER PER PLAN 2XBLOCKING 2XNAILER 2X8 SOLID BLOCKING MSTA 18 @ 32" O.C. 3-#4 (N) 4'' THK. CONCRETE SLAB W/ # 4 REBARS @ 16'' O.C.E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. 1/2" SEL. STRUCT PLYWOOD AT SHEAR WALL 8d @ 4" O.C. EDGE NAILING UNLESS OTHERWISE STATED ON PLAN. 2X4 @ 12" O.C. D.F., GR. 1 AS 35 @ 16" O.C. 2xJOIST D.F. GR. 1 2X4 STUD WALL @ 16" O.C. 8d @ 4" O.C. UNLESS OTHERWISE STATED ON PLAN REFER TO UBC NAILING SCH. FOR OTHER NAILING NOT SHOW HERE ON PLAN 15/32" STRUCT. 1 PLY NAILING PER PLAN 2XRAFTER D.F. GR. 1 PROVIDE A WEEP SCREED FOR STUCCO AT THE FUNDATION PLATE LINE A MINIMUM OF 4" ABOVE GADE 24 " MI N I M U M 8d @ 6" O.C. BOUNDARY NAILING UNLESS OTHERWISE STATED ON PLAN 6" MI N 4" "3/8" THK. CDX EXTERIOR PLYWOOD. (MATCH EXISTING EXTERIOR FINISH) "7/8" THK. EXTERIOR PLASTER OVER MIN. 15# BUILIDNG PAPER OVER BUILDING PAPER OVER METAL LATH PROVIDE R-13 MINIMUM WALL INSULATION, UNLESS NOTED ON TITLE 24 CALCULATIONS GALVANIZED IRON SILL PLATE, TYPICAL AT GROUND LEVEL #4 @ 16" O.C. E.W. 4" THK. SLAB NEW 4" THICK CONC. SLAB W/ #4 REBARS AT 16" O.C. E.W.; OVER 6-MIL MOISTURE BARRIER OVER 4" OF 1/2" CLEAN AGGREGATE OVER 90% RELATIVE COMPACTION. AS PER PLAN POLYETHYLENE VAPOR BARRIER EXTENDED UNDER GRADE BEAM WHERE IT ALSO ACTS AS A CAPILLARY BREAKNOTE: 1.F'c= 2, 500 PSI 2.Fy= 60, 000 PSI CONCRETE GRADE BEAM 2-#4 CONTINUOS BARS 24 " MI N I M U M 18'' REINF PER PLAN 1'-6"24 ' ' 5/8"Ø x 9" EMBED AB @ 48" OC MAX #4 @ 16" OC ALT BENDS WALL PER PLAN SLAB ON GRADE PER PLAN C OF RIDGEL SIMPSON MSTI 36 @ 4'-0" O.C. RAFTER AS SIMPSON "HUS" JOIST HANGER PLYWD. SHEATHING RIDGE BEAM PLYWD. SHEATHING RAFTER AS 1'-0" 5-16d NAILS CON'T G.I.TRIM 2X K.D. FASCIA BD. 2X SOLID BLOCKING. 2-2X TOP PLATE 16d TOE NAILS @ 6" O.C. BDRY NAILS 2X ROOF RAFTERS PER PLAN PLYWOOD SHEATHING PER PLAN SIMP. A35 @ 16" 0.C., TYP. 1/2" THK. GYP. BD. ON 2X CEIL. JOIST WALL INSUL. PER T24 1/2" THK. GYPSUM ON 2X6 STUDS @ 24" O.C. TYP. ROOF INSUL. R-38 PER T24 NOTE: HIGH PERFORMANCE ROOF PER 24 PLYWOOD SHEATHING (SHEAR WALL) PER PLAN SCALE 3/4" = 1'-0" HEADER6 SCALE 3/4" = 1'-0" KING POST5 SCALE 3/4" = 1'-0" PAD FOOTING ST R U C T U R A L D E T A I L S EXTERIOR FOOTING SCALE3.2 1 1" = 1'-0" SCALE 1" = 1'-0" BALLOON FRAMING11 2 SCALE 3/4" = 1'-0" KING POST 3.2 3.2 3.2 3.2 3.2 SCALE 1/4" = 1'-0" LOAD PATH DETAIL13 3.2 NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 SCALE 1 1/2" = 1'-0" NO-BEARING WALL 3.2 8 SLAB-ON-GRADE SCALE3.2 3 1" = 1'-0" WEEP SCREED SCALE3.2 4 1" = 1'-0" SCALE 1 1/2" = 1'-0" TYPICAL ROOF EAVES 3.2 14 INTERIOR FOOTING SCALE3.2 12 1" = 1'-0" SCALE 1 1/2" = 1'-0" RIDGE 3.2 10 SCALE 1" = 1'-0" BEAM-POST 3.2 02-S-3.2 ST R U C T U R A L D E T A I L S NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 02-S3.3 ST R U C T U R A L D E T A I L S NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 02-S-3.3 ST R U C T U R A L D E T A I L S NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 02-S-3.4 20 2 2 C A L I F O R N I A G R E E N B U I L D I N G ST A N D A R D S C O D E RE S I D E N T I A L M A N D A T O R Y M E A S U R E S NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 03-G-005 NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 03-G-006 20 2 2 C A L I F O R N I A G R E E N B U I L D I N G ST A N D A R D S C O D E RE S I D E N T I A L M A N D A T O R Y M E A S U R E S T2 4 NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 03-G-008 T2 4 NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 03-G-009 T2 4 NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 03-G-010 T2 4 NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 03-G-4.0 T2 4 NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 03-G-4.1 N. LEWIS ST. G E (E) WATER HEATER (E) ELECTRIC METER E ET L I N E LINE T L I N E N . L E W I S S T . ET L I N E ET LINE ET LINE E ENE (E) GAS METER CP E LNTE E E SIEWL E SIEWL E E N E E E N E (E) TREE W (E) WATER METER (E) TREE (E) CONCRETE PAVEMENT A/C COND. UNIT (E) A/C CONDENSER E (E) PLANTER AREA (E) PLANTER A R E A (E ) F E N C E (E ) P L A N T E R A R E A (E) PAVER BL O C K S (E) PAVER BLOCKS (E) PAVED/ PLAYGROUND AREA #2121 EXISTING MAIN HOUSE (NOT IN CONTRACT) EXISTING 2-CAR GARAGE (NIC) (E ) P A V E R B L O C K S (E ) P L A N T E R A R E A (E ) P A V E R B L O C K S (E) CONCRETE PAVEMENT (E) CONCRETE DRIVEWAY (E) LANDSCAPE (E) PLANTER AREA (E) PLANTER AREA (E) GATE (E) GATE (E) PAVED AREA (E ) P L A N T E R A R E A (E ) P A V E R B L O C K S DRYERWASHER (E) WASHER AND DRYER EXISTING PATIO TO BE DEMOLISHED AND CONVERT TO OPEN AREA WOOD TRELLIS AREAROOF AREA LI N E O F ( E ) P A T I O S T R U C T U R E EXISTING SITE PLAN SCALE: 1/8" = 1'-0" N NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 EX I S T I N G S I T E P L A N 04-C-200 19 ' - 5 " 12'-10" MASTER'S BEDROOM BEDROOM #1 5' REFD/W 5' - 5 " 11' 33'-7" 47'-3" LIVING 13'-8" 10 ' - 1 0 " E WH A/C COND. UNIT #2121 EXISTING MAIN HOUSE (NOT IN CONTRACT) SD CM SD SD 5' CLOSET CL O S E T 11'-4" WASHER /DRYER STORAGE KITCHEN /DINING BATH #1 BATH #2 MAIN ENTRANCE CLOSET 6' A/C COND. UNIT 16 ' - 3 " 1' 4' 1' RANGE SD CM SD CM E G IAQ PR O P O S E D E L E C T R I C A L P L A N NO.REVISIONS DATE CONSULTANT JOB NO: DATE: 1ST REV: DRAWN: PLOTTED: SCALE:AS SHOWN PR O J E C T : OW N E R : AD D R E S S : T: 323.470.0181 E: kmassociatesince@outlook.com KM ASSOCIATES INC. 16202 ORION AVE CHINO CA 91708 PR O P O S E D A C C E S S O R Y D W E L L I N G U N I T LI N H L E A N D D A V I D F R E U D E N B E R G E R SHEET TITLE SHEET NUMBER 21 2 1 N . L E W I S S T . A N D 2 1 2 1 N . L E W I S S T . # 2 , SA N T A A N A , C A 92 7 0 6 - 2 2 3 6 SCALE 1/4" = 1'-0" PROPOSED ELECTRICAL PLAN (ADU)1 05-E-102 ELECTRICAL GENERAL NOTES: 1.GENERAL CONTRACTOR SHALL VERIFY EXISTING CONDITION BEFORE AND DURING CONSTRUCTION. 2.ALL WORKS SHALL COMPLY WITH LOCAL AND APPLICABLE CODES AND REGULATIONS. 3.CONTRACTOR SHALL OBTAIN NECESSARY BUILDING PERMIT PRIOR TO CONSTRUCTION. THIS PLAN IS A SCOPING PLAN FOR PERMITTING PURPOSES. ELECTRICAL CONTRACTOR CAN PROPOSE ALTERNATE DESIGN IN LIEU OF THIS PLAN; BASED ON ACTUAL CONDITION. CONSIDER CONTINGENCIES ON BID. NO CHANGE ORDER IS ALLOWED WITHIN THE SCOPE OF THIS PROJECT. ADDITIONAL NOTES: 1.OUTLETS AREA AFCI AND GFCI. 2.ALL LIGHTS ARE TO BE HIGH EFFICACY W/ NO EXCEPTION. 3.ALL LIGHTS ARE CONTROLLED BY DAYLIGHT CONTROL DIMMER, TIMER, MOTION SENSOR, OCCUPANCY DETECTION PER CODE. EXHAUST FAN NOTES: 1.FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE TO THE OUTSIDE OF THE BUILDING, MAX. OF 3 ZONES. 2.FANS NOT FUNCTIONING AS COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, MUST BE CONTROLLED BY A HUMIDITY CONTROLLER. ELECTRICAL NOTES: 1.ALL BRANCH CIRCUITS SUPPLYING 120V 15-AMPERE AND 20-AMPEREOUTLETS IN DWELLING KITCHEN, FAMILY ROOMS, DINING ROOMS , LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER. SHOW ON THE PLANS. (210.12(A) CEC). 2.ALL WALL SPACES 2' OR MORE IN WIDTH, SHALL HAVE RECEPTACLES INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY SIS MORE THAN 6' FROM A RECEPTACLE (12' MAXIMUM SPACING). SHOW MINIMUM RECEPTACLES ON THE PLANS. (210.52 (A) (1) AND (2) CEC). 3.SERVICES SUPPLYING DWELLING UNITS SHALL HAVE TYPE 1 OR TYPE 2 SURGE PROTECTION DEVICE, PER CEC SECTION 230.67. THIS ALSO INCLUDES ANY NEW SERVICE OR SERVICE REPLACEMENTS/UPGRADES ON EXISTING PREMISES. 4.AT LEAST ONE RECEPTACLE AT GRADE LEVEL SHALL BE INSTALLED IN BOTH THE FRONT AND BACK OF EACH DWELLING UNIT. SHOW GFCI WATERPROOFED RECEPTACLES ON THE PLANS. (CEC 210.52 (E) (1)). SD CM GFCI LEGEND: SMOKE AN CARBON MONOXIDE DETECTOR INTERCONNECTED HARDWIRED WITH BATTERY BACKUP. 50CFM ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE TO THE OUTSIDE OF THE BUILDING. FANS, NOT FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, MUST BE CONTROLLED BY A HUMIDITY CONTROLLER. LED DOWN LIGHT, RECESSED MOUNT. DUPLEX RECEPTACLE, WALL MOUNTED. GROUND FAULT CIRCUIT INTERRUPTED, WALL MOUNTED. WP, WATER-PROOFED. IAQ EXHAUST FAN TYPE. 0.35 FAN EFFICIENCY, 45 CFM AIRFLOW PER T24 SUPPLY DIFFUSER (SA) RETURN AIR GRILLE (RA) O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR STRUCTURAL CALCULATIONS PROPOSED ACCESSORY DWELLING UNIT 2121 LEWIS ST AND 2121 LEWIS ST #2 SANTA ANA, CA 97206-2236 & SEPTEER 16, 202 P SEPTEMBER 22, 2025 Project: Proposed ADU Sheet 2 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: TABLE OF CONTENTS A. DESIGN CRITERIA SHEET NO. A.1 Building Description 3 A.2 Reference Code 3 A.3 Materials 3 A.4 Soils Report Information 3 A.5 Dead and Live Loads 4 A.5.1 Key Plan 5 A.6 Building Weight 6 A.7 Seismic Load & Base Distribution 7-10 A.8 Wind Calcs 11 B. DESIGN OF DIAPHRAGM SHEATHING B.1 Roof Diaphragm 12 C. DESIGN OF SHEAR WALLS 13 14 15 D. JOIST AND RAFTER DESIGN D.1 Roof Rafter Design 16 D.2 Ceiling Joist 17 E. FOOTING DESIGN E.1 Footing Design 18 F. BEAM F.1 4x12 BEAM 19 F.2 3.5x11.875 PSL 2.0E 21 F.3 4X12 HDR 23 F.4 3' x 5' x 2' WSWH Footing 25 C.3 WSWH C.2 SHEAR WALL (Load on East-West Direction) KM Associates Inc Structural Calculation Sheet 7/25/2025 C.1 SHEAR WALL (Load on North-South Direction) 8/1us ↑ 4 6 8/269/15/2025 HDR 4x12 BEAM 4x10 BEAM 3.5x11.875 PSL 2.0E 4'x6'x2' WSWH FOOTINGF.5 27 = 6x10 22 Project: Proposed ADU Sheet 3 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: A.5 DEAD LOAD / LIVE LOAD I.Roof Dead Load Comp Built-up Roof 6.50 Struct 1 Plywood or OSB 1.50 Roof Rafters 2.50 Ceiling Joist 2.50 Insulation 0.50 1/2" Gypboard 1.50 Misc Elec and Mech Items 1.00 Total 16.00 psf Roof Live Load 20.00 psf III.Exterior Wall 1" Cement Plaster 7.50 psf Struct 1 Plywood or OSB 1.50 Stud 2.50 5/8" Gypboard 2.50 Total 14.00 psf IV.Interior Wall 5.00 psf Structural Calculation SheetKM Associates Inc 5/27/2025 Project: Proposed ADU Sheet 4 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: A. DESIGN CRITERIA A.1 Building Description This calculation is for the analysis and design of the proposed ADU. This calculation will show the checking of Wind and Seismic Load Design. Wood diaphragm and Wood Framing as LFRS is included in this calcs. The analysis is limited to the new SW and Diaphram Calcs, but the whole bldg will be analyze for Base Shear and Diapghram load A.2 Codes 1. 2023 California Residential Code & CBC; and local agency ammendment 2. ACI, Building Code Requirements for Reinforced Concrete 318 3. ASCE 7 (For Seismic Design Criteria) 4. National Design Specifications, (For Lumbers) A.3 Materials 1. Concrete fc’=2500 psi at 28 days 2. Steel Reinforcement Grade 60 ASTM A615 3. Structural Lumber: Douglas Fir, WCLIB Grading Rule #18, Grade 1 3.1 Beam: Douglas Fir, WCLIB Grading Rule #18, Grade 1 and better 3.2 Column/Post: Douglas Fir, WCLIB Grading Rule #18, Grade 1 3.3 Rafter: Douglas Fir, WCLIB Grading Rule #18, Grade 1 4. Steel Bolts ASTM A325 A.4 Soils Report : No Soils Report Available. Use Least Allowable Bearing Pressure = 1,500 psf (per CBC) KM Associates Inc Structural Calculation Sheet 5/27/2025 Project: Proposed ADU Sheet 5 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: KM Associates Inc Structural Calculation Sheet 5/27/2025 ·num - d I D => m · 8/1us & 8/269/15/2025I w G Project: Proposed ADU Sheet 6 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: A.6. BUILDING WEIGHT WITHIN AND THE NEW ADDITION, AND ADJACENT AREA; 45.75' X 28' A.6.1 NORTH-SOUTH DIRECTION ROOF 1.Building Size to GF 21.5 feet span by 49.25 feet wide (ave) 2.Tributary Building Height Roof to Second Flr:10.25 feet (Mean Roof Height) 3.Building Weight Wt (psf)Area (sf)Wt (lbs) Roof 16.00 1058.9 16,942 1/2 Walls (2nd Level)14.00 220.4 3,085 W =20,027 lbs A.6.2 EAST-WEST DIRECTION ROOF 1.Building Size to GF 49.25 feet span by 21.5 feet wide 2.Tributary Building Height Roof to Second Flr:10.25 feet (Mean Roof Height) 3.Building Weight Wt (psf)Area (sf)Wt (lbs) Roof 16.00 1058.9 16,942 1/2 Walls (2nd Level)14.00 504.8 7,067 W =24,009 lbs Since the load is almost the same, use the larger load in determining base shear and diaphragm loads, and apply to both directions. KM Associates Inc Structural Calculation Sheet 5/27/2025 ASCE 7-16 Seismic Base Shear LIC# : KW-06011877, Build:20.24.04.09 Mike Santos (c) ENERCALC INC 1983-2023 DESCRIPTION:Seismic Base Shear Analysis Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: Risk Category ASCE 7-16, Page 4, Table 1.5-1 Calculations per ASCE 7-16 "II" : All Buildings and other structures except those listed as Category I, III, and IV Risk Category of Building or Other Structure : Seismic Importance Factor =1 ASCE 7-16, Page 5, Table 1.5-2 Specific Description: Seismic Loads in the North-South Direction USER DEFINED Ground Motion ASCE 7-16 11.4.2 Max. Ground Motions, 5% Damping : S =1.331 Longitude =0.000 deg West S Latitude =0.000 g, 0.2 sec response deg North S 0.47301 g, 1.0 sec response= For the closest datapoint grid location . . . Site Class, Site Coeff. and Design Category Classification:ASCE 7-16 Table 20.3-1"D" : Shear Wave Velocity 600 to 1,200 ft/sec =D Site Coefficients Fa & Fv ASCE 7-16 Table 11.4-1 & 11.4-2 (using straight-line interpolation from table values) Fa =1.20 Fv =1.83 Maximum Considered Earthquake Acceleration ASCE 7-16 Eq. 11.4-1S = Fa * Ss 1.597=MS S = Fv * S1 =0.864M1 ASCE 7-16 Eq. 11.4-2 Design Spectral Acceleration ASCE 7-16 Eq. 11.4-3S = S * 2/3 =1.065DSMS =0.576 ASCE 7-16 Eq. 11.4-4S = S * 2/3D1M1 Seismic Design Category ASCE 7-16 Table 11.6-1 & -2=D (By Default per 11.4.3) Resisting System ASCE 7-16 Table 12.2-1 Basic Seismic Force Resisting System . . .Bearing Wall Systems 1.Special reinforced concrete shear walls NOTE! See ASCE 7-16 for all applicable footnotes. Building height Limits :Response Modification Coefficient " R "=5.00 Category "A & B" Limit:No LimitSystem Overstrength Factor " Wo "=2.50 Category "C" Limit:No LimitDeflection Amplification Factor " Cd "=5.00 Category "D" Limit:Limit = 160 Category "E" Limit:Limit = 160 Category "F" Limit:Limit = 100 Lateral Force Procedure ASCE 7-16 Section 12.8.2 Equivalent Lateral Force Procedure The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE 7-16 12.8 Use ASCE 12.8-7Determine Building Period Structure Type for Building Period Calculation :All Other Structural Systems " Ct " value 0.020= " x " value " hn " : Height from base to highest level =10.250 ft " Ta " Approximate fundemental period using Eq. 12.8-7 : 8.000"TL" : Long-period transition period per ASCE 7-16 Maps 22-14 -> 22-17 sec Ta = Ct * (hn ^ x) =0.115 0.75 sec = Building Period " Ta " Calculated from Approximate Method selected=0.115 " Cs " Response Coefficient ASCE 7-16 Section 12.8.1.1 S : Short Period Design Spectral Response 1.065 " R " : Response Modification Factor 5.00 " I " : Seismic Importance Factor =1 0.213From Eq. 12.8-2, Preliminary Cs = 1.006From Eq. 12.8-3 & 12.8-4 , Cs need not exceed= From Eq. 12.8-5 & 12.8-6, Cs not be less than =0.047 DS =Cs : Seismic Response Coefficient =0.2130 = = ASCE 7-16 Seismic Base Shear LIC# : KW-06011877, Build:20.24.04.09 Mike Santos (c) ENERCALC INC 1983-2023 DESCRIPTION:Seismic Base Shear Analysis Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: Seismic Base Shear ASCE 7-16 Section 12.8.1 W ( see Sum Wi below ) =20.03 kCs =0.2130 from 12.8.1.1 Seismic Base Shear V = Cs * W =4.26 k Vertical Distribution of Seismic Forces ASCE 7-16 Section 12.8.3 " k " : hx exponent based on Ta =1.00 Table of building Weights by Floor Level... Wi : Weight Hi : Height (Wi * Hi^k)Cvx Fx=Cvx * V Sum Story Shear Sum Story MomentLevel # 1 20.03 10.25 205.28 1.0000 4.26 4.26 0.00 Sum Wi =20.03 k Total Base Shear =4.26 k Base Moment = 205.28 k-ftSum Wi * Hi = 43.7 k-ft Diaphragm Forces : Seismic Design Category "B" to "F"ASCE 7-16 12.10.1.1 Level #Wi Fi Fpx : MaxFpx : CalcdSum Fi Sum Wi Fpx Dsgn. ForceFpx : Min 1 20.03 4.26 4.26 20.03 4.26 4.26 8.53 4.26 4.26 Wpx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Weight at level of diaphragm and other structure elements attached to it. Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Design Lateral Force applied at the level. Sum Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Sum of "Lat. Force" of current level plus all levels above 0.20 * S * I * WpxMIN Req'd Force @ Level . . . . . . . . . .DS DSMAX Req'd Force @ Level . . . . . . . . . .0.40 * S * I * Wpx Fpx : Design Force @ Level . . . . . . . . . .Wpx * SUM(x->n) Fi / SUM(x->n) wi, x = Current level, n = Top Level ASCE 7-16 Seismic Base Shear LIC# : KW-06011877, Build:20.24.04.09 Mike Santos (c) ENERCALC INC 1983-2023 DESCRIPTION:Seismic Base Shear Analysis Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: Risk Category ASCE 7-16, Page 4, Table 1.5-1 Calculations per ASCE 7-16 "II" : All Buildings and other structures except those listed as Category I, III, and IV Risk Category of Building or Other Structure : Seismic Importance Factor =1 ASCE 7-16, Page 5, Table 1.5-2 Specific Description: Seismic Loads in the East-West Direction USER DEFINED Ground Motion ASCE 7-16 11.4.2 Max. Ground Motions, 5% Damping : S =1.331 Longitude =0.000 deg West S Latitude =0.000 g, 0.2 sec response deg North S 0.47301 g, 1.0 sec response= For the closest datapoint grid location . . . Site Class, Site Coeff. and Design Category Classification:ASCE 7-16 Table 20.3-1"D" : Shear Wave Velocity 600 to 1,200 ft/sec =D Site Coefficients Fa & Fv ASCE 7-16 Table 11.4-1 & 11.4-2 (using straight-line interpolation from table values) Fa =1.20 Fv =1.83 Maximum Considered Earthquake Acceleration ASCE 7-16 Eq. 11.4-1S = Fa * Ss 1.597=MS S = Fv * S1 =0.864M1 ASCE 7-16 Eq. 11.4-2 Design Spectral Acceleration ASCE 7-16 Eq. 11.4-3S = S * 2/3 =1.065DSMS =0.576 ASCE 7-16 Eq. 11.4-4S = S * 2/3D1M1 Seismic Design Category ASCE 7-16 Table 11.6-1 & -2=D (By Default per 11.4.3) Resisting System ASCE 7-16 Table 12.2-1 Basic Seismic Force Resisting System . . .Bearing Wall Systems 1.Special reinforced concrete shear walls NOTE! See ASCE 7-16 for all applicable footnotes. Building height Limits :Response Modification Coefficient " R "=5.00 Category "A & B" Limit:No LimitSystem Overstrength Factor " Wo "=2.50 Category "C" Limit:No LimitDeflection Amplification Factor " Cd "=5.00 Category "D" Limit:Limit = 160 Category "E" Limit:Limit = 160 Category "F" Limit:Limit = 100 Lateral Force Procedure ASCE 7-16 Section 12.8.2 Equivalent Lateral Force Procedure The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE 7-16 12.8 Use ASCE 12.8-7Determine Building Period Structure Type for Building Period Calculation :All Other Structural Systems " Ct " value 0.020= " x " value " hn " : Height from base to highest level =10.250 ft " Ta " Approximate fundemental period using Eq. 12.8-7 : 8.000"TL" : Long-period transition period per ASCE 7-16 Maps 22-14 -> 22-17 sec Ta = Ct * (hn ^ x) =0.115 0.75 sec = Building Period " Ta " Calculated from Approximate Method selected=0.115 " Cs " Response Coefficient ASCE 7-16 Section 12.8.1.1 S : Short Period Design Spectral Response 1.065 " R " : Response Modification Factor 5.00 " I " : Seismic Importance Factor =1 0.213From Eq. 12.8-2, Preliminary Cs = 1.006From Eq. 12.8-3 & 12.8-4 , Cs need not exceed= From Eq. 12.8-5 & 12.8-6, Cs not be less than =0.047 DS =Cs : Seismic Response Coefficient =0.2130 = = ASCE 7-16 Seismic Base Shear LIC# : KW-06011877, Build:20.24.04.09 Mike Santos (c) ENERCALC INC 1983-2023 DESCRIPTION:Seismic Base Shear Analysis Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: Seismic Base Shear ASCE 7-16 Section 12.8.1 W ( see Sum Wi below ) =24.01 kCs =0.2130 from 12.8.1.1 Seismic Base Shear V = Cs * W =5.11 k Vertical Distribution of Seismic Forces ASCE 7-16 Section 12.8.3 " k " : hx exponent based on Ta =1.00 Table of building Weights by Floor Level... Wi : Weight Hi : Height (Wi * Hi^k)Cvx Fx=Cvx * V Sum Story Shear Sum Story MomentLevel # 1 24.01 10.25 246.09 1.0000 5.11 5.11 0.00 Sum Wi =24.01 k Total Base Shear =5.11 k Base Moment = 246.09 k-ftSum Wi * Hi = 52.4 k-ft Diaphragm Forces : Seismic Design Category "B" to "F"ASCE 7-16 12.10.1.1 Level #Wi Fi Fpx : MaxFpx : CalcdSum Fi Sum Wi Fpx Dsgn. ForceFpx : Min 1 24.01 5.11 5.11 24.01 5.11 5.11 10.23 5.11 5.11 Wpx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Weight at level of diaphragm and other structure elements attached to it. Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Design Lateral Force applied at the level. Sum Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Sum of "Lat. Force" of current level plus all levels above 0.20 * S * I * WpxMIN Req'd Force @ Level . . . . . . . . . .DS DSMAX Req'd Force @ Level . . . . . . . . . .0.40 * S * I * Wpx Fpx : Design Force @ Level . . . . . . . . . .Wpx * SUM(x->n) Fi / SUM(x->n) wi, x = Current level, n = Top Level Project: Proposed ADU Sheet 11 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: A.8 WIND CALCS Wind Exposure Category = C V = 110.00 mph kz =0.85 kd =0.85 kzt =1.00 Wind Load :(Exposure "C") Velocity Pressure, qz qz = 0.00256 * kz * kzt * kd * V2 qz = 0.00256 * (0.85) * (1.0) * (0.85) * (110) 2 qz =22.38 PSF Building: Enclosed / Partially Enclosed P = q * G * cp q = qz = 22.38 PSF G =0.85 Cp =0.80 P = (22.38) * (0.85) * (0.80) P=15.22 PSF (Design Wid Pressure) Area on N-S Direction (to be compared to Seismic Loading) Building Length =21.50 ft (larger surface area) Tributary Height =12 ft (Ave. Height, Acting on Diaphragm Level) At =258 SF Wind Force = P * At Wind Force =(15.22 PSF) * (1100 SF) / 2 Wind Force =1.96 kips (acting on diapragm level) (East-West) Since Wind Force < Seismic Diap. Force Therefore, Seismic Force Governs KM Associates Inc Structural Calculation Sheet 5/27/2025 Project: Proposed ADU Sheet 12 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: B DESIGN OF DIAPHRAGM SHEATHING B.1 ROOF DIAPHRAGM 1.Diaphragm Load =5.110 kips w =231.79 plf ASD Design =3.833 kips With Redeundancy (1.3) =4.983 kips 2.Diaphragm Span (L) = 21.50 ft Ratio =0.44 :1 < 4:1 OK Diaphragm Depth (D) = 49.25 ft . 3.Diaphragm Shear Force = 0.5 x Diaphragm Load =2,491.7 lbs 4.Diaphragm Unit Shear Force =0.5*w*L/D =50.59 plf 5.Using nominal 15/32 Thk. Plywood with 8D nailing at 6"-6"-12" Blocked Diapragm 175 plf >50.59 plf OK Per CBC Table 2306.2 On Plan: Use 15/32" OSB (Rated Sheathing) with Radiant Barrier CHORD DESIGN - (METAL STRAP DESIGN WHERE NEEDED) Moment = 0.125 x w x L^2 =13,393.15 ft-lbs. T = C = Moment / D 271.94 lbs. Using MSTA36- Strap, Capacity =2,000.00 lbs.>271.94 OK KM Associates Inc Structural Calculation Sheet 5/27/2025 Project: Proposed ADU Sheet 13 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: C. SHEAR WALL (Cont) C.1 SHEAR WALL (Load on North-South Direction)w =148.98 plf Horizontal Lateral Force Due to Roof Lateral Load= 4.26 Kips TOTAL LATERAL LOAD (ASD) =3.20 Kips Lateral Force Each End = 0.80 kips Lateral Force in the Middle =1.60 kips Span (Length) =21.50 ft 4.00 ft 8.00 ft (from floor to floor) 5.00 psf 2.0 >,=2 OK Weight of Shear Wall=720.00 lbs Total Width of Shear Wall (Each End) =18.00 ft. Total Width of Shear Wall (Middle) =6.00 ft. V = wL/2 =1,601.5 lbs. Unit Shear = v = V/b =266.92 plf (middle)44.49 plf (sides) Per CBC 15/32" MIN PLYWOOD (1/2" gross) with Table 2306.3, using:10D at 6" panel edges & 12" field. Allowable Shear (middle) =280 plf >266.92 plf OK Allowable Shear (each end) =280 plf >44.49 plf OK CHECK FOR OVERTURNING MOMENTS OF WALL Fx*h =9 k-ft shear wall weight= 0.16 k-ft Weight of roof=1.72 k-ft Solving for Tension (T) =4.78 k add HDU5 each shearwall with less Wall Weight = Aspect ratio(h/b) = Least Shear Wall Width (b) = KM Associates Inc Structural Calculation Sheet 5/27/2025 Net Wall Height (h) = Project: Proposed ADU Sheet 14 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: C. SHEAR WALL (Cont) C.2 SHEAR WALL (Load on East-West Direction)w =78.01 plf Horizontal Lateral Force Due to Roof Lateral Load= 5.11 Kips TOTAL LATERAL LOAD (ASD) =3.84 Kips Lateral Force Each End = 0.96 kips Lateral Force in the Middle =1.92 kips Span (Length) =49.25 ft 4.00 ft 8.00 ft (from floor to floor) 5.00 psf 2.0 >,=2 OK Weight of Shear Wall=160.00 lbs Total Width of Shear Wall (Each End) =4.00 ft. Total Width of Shear Wall (Middle) =12.00 ft. V = wL/2 =1,921.1 lbs. Unit Shear = v = V/b =160.09 plf (middle)240.13 plf (sides) Per CBC 15/32" MIN PLYWOOD (1/2" gross) with Table 2306.3, using:10D at 6" panel edges & 12" field. Allowable Shear (middle) =340 plf >160.09 plf OK Allowable Shear (each end) =340 plf >240.13 plf OK CHECK FOR OVERTURNING MOMENTS OF WALL Fx*h =5 k-ft shear wall weight= 0.16 k-ft Weight of roof=3.94 k-ft Solving for Tension (T) =-3.08 k add HDU5 each shearwall with less Aspect ratio(h/b) = KM Associates Inc Structural Calculation Sheet 5/27/2025 Least Shear Wall Width (b) = Net Wall Height (h) = Wall Weight = Project: Proposed ADU Sheet 15 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: C. SHEAR WALL (Cont) C.3 WSWH (Load on East-West Direction)w =78.01 plf Horizontal Lateral Force Due to Roof Lateral Load= 5.11 Kips TOTAL LATERAL LOAD (ASD) =3.84 Kips Lateral Force Each End = 0.96 kips Lateral Force in the Middle =1.92 kips Allowable Shear (Seismic) For Simpsons Strong Wall:5,950 lbs 5,950 lbs > 1,921.05 lbs Therefore, OK KM Associates Inc Structural Calculation Sheet 5/27/2025 Project: Proposed ADU Sheet 16 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: D.1 ROOF RAFTER, USE C.R.C. - Table R 802.5.1 Req'd Span = 10 ft (longest span per plan) From CRC Table R 802.5.1; (Use DL=20 psf to be more conservative) Span Allowed for 2x10 at 16 in. , on center For: Douglas Fir, #1 Allowable Span Length =20'-7"(in-between)Therefore, OK. KM Associates Inc Structural Calculation Sheet 5/27/2025 Project: Proposed ADU Sheet 17 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: D.2 CEILING JOIST (a)New Building: Req'd Span = 10 ft (longest span per plan) (Note, Ceiling has NO Storrage and Uninhabitable) From CRC, Table R 802.4 Span Allowed for 2x10 at 16 in. , on center For: Douglas Fir, #1 Span Length =18'-1" Therefore, OK. KM Associates Inc Structural Calculation Sheet 5/27/2025 2x8 23'-10" 8/1USA W u us Project: Proposed ADU Sheet 18 Address:2121 LEWIS ST AND 2121 LEWIS ST #2 Job No.2025-7 SANTA ANA, CA 97206-2236 Date: E.1 FOOTING From CRC TABLE R403.1 For 1-Story Conventional Light-Frame Construction; use: 12 inch wide footing at 1,500 PSF (Note, Use 1,500 PSF per CBC as worst condition, if project has No Soil's Report) Per Plan: 12" Wide Footing KM Associates Inc Structural Calculation Sheet 5/27/2025 Wood Beam LIC# : KW-06011877, Build:20.25.07.09 Mike Santos (c) ENERCALC, LLC 1982-2025 DESCRIPTION:6x10 HDR Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: Referenced Design Standard(s) : NDS 2018 Load Combination Set : IBC 2021 Code References Governing Code : IBC 2018, CBC 2019 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch (North) No. 1/No. 2 850.0 850.0 1,400.0 625.0 1,600.0 580.0 180.0 500.0 30.590 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2021 6x10 Span = 8.0 ft 1 2 D(0.112) Lr(0.14) .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0160, Lr = 0.020 ksf, Tributary Width = 7.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.275: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 4.000 ft 23.23 psi= = 1,062.50 psi 6x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 6x10 Maximum Shear Stress Ratio 0.103 : 1 7.212 ft= = 292.42 psi Maximum Deflection 4650 <360 2583 Ratio =0 <180 Max Downward Transient Deflection 0.021 in 0 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.037 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 8.0 ft 1 0.170 0.064 0.90 1.000 1.001.00 1.00 0.90 130.0 765.0 0.36 162.01.00 10.31.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.275 0.103 1.25 1.000 1.001.00 1.00 2.02 292.4 1,062.5 0.81 225.01.00 23.21.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.237 0.089 1.25 1.000 1.001.00 1.00 1.74 251.8 1,062.5 0.70 225.01.00 20.01.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.057 0.022 1.60 1.000 1.001.00 1.00 0.54 78.0 1,360.0 0.22 288.01.00 6.21.00 . Wood Beam LIC# : KW-06011877, Build:20.25.07.09 Mike Santos (c) ENERCALC, LLC 1982-2025 DESCRIPTION:6x10 HDR Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+Lr1 0.0372 4.029 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.008 1.008 Max Upward from Load Combinations 1.008 1.008 Max Upward from Load Cases 0.560 0.560 D Only 0.448 0.448 +D+Lr 1.008 1.008 +D+0.750Lr 0.868 0.868 +0.60D 0.269 0.269 Lr Only 0.560 0.560 Wood Beam LIC# : KW-06011877, Build:20.25.07.09 Mike Santos (c) ENERCALC, LLC 1982-2025 DESCRIPTION:4x12 BEAM Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2018, CBC 2019 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch (North) No. 1/No. 2 850.0 850.0 1,400.0 625.0 1,600.0 580.0 180.0 500.0 30.590 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 4x12 Span = 11.50 ft 1 2 D(0.08) Lr(0.1) .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0160, Lr = 0.020 ksf, Tributary Width = 5.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.414: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 5.750 ft 33.10 psi= = 1,168.75 psi 4x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x12 Maximum Shear Stress Ratio 0.147 : 1 0.000 ft= = 483.66 psi Maximum Deflection 2316 <360 1286 Ratio =0 <180 Max Downward Transient Deflection 0.060 in 0 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.107 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 11.50 ft 1 0.255 0.091 0.90 1.100 1.001.00 1.00 1.32 215.0 841.5 0.39 162.01.00 14.71.00 1.00+D+Lr 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.50 ft 1 0.414 0.147 1.25 1.100 1.001.00 1.00 2.98 483.7 1,168.8 0.87 225.01.00 33.11.00 1.00+D+0.750Lr 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.50 ft 1 0.356 0.127 1.25 1.100 1.001.00 1.00 2.56 416.5 1,168.8 0.75 225.01.00 28.51.00 1.00+0.60D 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.50 ft 1 0.086 0.031 1.60 1.100 1.001.00 1.00 0.79 129.0 1,496.0 0.23 288.01.00 8.81.00 . Wood Beam LIC# : KW-06011877, Build:20.25.07.09 Mike Santos (c) ENERCALC, LLC 1982-2025 DESCRIPTION:4x12 BEAM Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+Lr1 0.1072 5.792 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.035 1.035 Max Upward from Load Combinations 1.035 1.035 Max Upward from Load Cases 0.575 0.575 D Only 0.460 0.460 +D+Lr 1.035 1.035 +D+0.750Lr 0.891 0.891 +0.60D 0.276 0.276 Lr Only 0.575 0.575 Wood Beam LIC# : KW-06011877, Build:20.25.07.09 Mike Santos (c) ENERCALC, LLC 1982-2025 DESCRIPTION:4x10 BEAM Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2018, CBC 2019 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch (North) No. 1/No. 2 850.0 850.0 1,400.0 625.0 1,600.0 580.0 180.0 500.0 30.590 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 4x10 Span = 5.50 ft 1 2 D(0.08) Lr(0.1) .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0160, Lr = 0.020 ksf, Tributary Width = 5.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.128: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 2.750 ft 16.57 psi= = 1,275.00 psi 4x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x10 Maximum Shear Stress Ratio 0.074 : 1 4.737 ft= = 163.64 psi Maximum Deflection 11770 <360 6539 Ratio =0 <180 Max Downward Transient Deflection 0.006 in 0 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.010 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 5.50 ft 1 0.079 0.045 0.90 1.200 1.001.00 1.00 0.30 72.7 918.0 0.16 162.01.00 7.41.00 1.00+D+Lr 1.200 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 5.50 ft 1 0.128 0.074 1.25 1.200 1.001.00 1.00 0.68 163.6 1,275.0 0.36 225.01.00 16.61.00 1.00+D+0.750Lr 1.200 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 5.50 ft 1 0.111 0.063 1.25 1.200 1.001.00 1.00 0.59 140.9 1,275.0 0.31 225.01.00 14.31.00 1.00+0.60D 1.200 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 5.50 ft 1 0.027 0.015 1.60 1.200 1.001.00 1.00 0.18 43.6 1,632.0 0.10 288.01.00 4.41.00 . Wood Beam LIC# : KW-06011877, Build:20.25.07.09 Mike Santos (c) ENERCALC, LLC 1982-2025 DESCRIPTION:4x10 BEAM Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+Lr1 0.0101 2.770 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.495 0.495 Max Upward from Load Combinations 0.495 0.495 Max Upward from Load Cases 0.275 0.275 D Only 0.220 0.220 +D+Lr 0.495 0.495 +D+0.750Lr 0.426 0.426 +0.60D 0.132 0.132 Lr Only 0.275 0.275 Wood Beam LIC# : KW-06011877, Build:20.25.07.09 Mike Santos (c) ENERCALC, LLC 1982-2025 DESCRIPTION:3.5x11.875 PSL 2.0E Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2018, CBC 2019 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 3.5x11.875 Span = 13.750 ft 1 2 D(0.128) Lr(0.16) .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0160, Lr = 0.020 ksf, Tributary Width = 8.0 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.274: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 6.875 ft 61.55 psi= = 3,629.22 psi 3.5x11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 362.50 psi== Section used for this span 3.5x11.875 Maximum Shear Stress Ratio 0.170 : 1 0.000 ft= = 992.90 psi Maximum Deflection 1245 <360 691 Ratio =0 <180 Max Downward Transient Deflection 0.133 in 0 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.239 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 13.750 ft 1 0.169 0.105 0.90 1.001 1.001.00 1.00 3.03 441.3 2,613.0 0.76 261.01.00 27.41.00 1.00+D+Lr 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 13.750 ft 1 0.274 0.170 1.25 1.001 1.001.00 1.00 6.81 992.9 3,629.2 1.71 362.51.00 61.51.00 1.00+D+0.750Lr 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 13.750 ft 1 0.236 0.146 1.25 1.001 1.001.00 1.00 5.86 855.0 3,629.2 1.47 362.51.00 53.01.00 1.00+0.60D 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 13.750 ft 1 0.057 0.035 1.60 1.001 1.001.00 1.00 1.82 264.8 4,645.4 0.45 464.01.00 16.41.00 . Wood Beam LIC# : KW-06011877, Build:20.25.07.09 Mike Santos (c) ENERCALC, LLC 1982-2025 DESCRIPTION:3.5x11.875 PSL 2.0E Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+Lr1 0.2385 6.925 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.980 1.980 Max Upward from Load Combinations 1.980 1.980 Max Upward from Load Cases 1.100 1.100 D Only 0.880 0.880 +D+Lr 1.980 1.980 +D+0.750Lr 1.705 1.705 +0.60D 0.528 0.528 Lr Only 1.100 1.100 General Footing LIC# : KW-06011877, Build:20.25.07.09 Mike Santos (c) ENERCALC, LLC 1982-2025 DESCRIPTION:4x6x2 WSWH Footing Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: Code References Calculations per ACI 318-14, IBC 2018, CBC 2019 Load Combinations Used : IBC 2021 General Information Material Properties Soil Design Values 1.0 Analysis Settings 250.0 ksi No ksfAllowable Soil Bearing = = 3.0 60.0 3,122.0 145.0 =0.30Flexure=0.90 Shear = Values 0.00180 Soil Passive Resistance (for Sliding) 1.0 = Increases based on footing plan dimension Add Pedestal Wt for Soil Pressure No: Use Pedestal wt for stability, mom & shear No: Allowable pressure increase per foot of depth =ksf when max. length or width is greater than =ft : = Add Ftg Wt for Soil Pressure Yes Yes:Use ftg wt for stability, moments & shears when footing base is below ft pcf Increase Bearing By Footing Weight =pcf Min. Overturning Safety Factor = : 1 Increases based on footing Depth0.750 = Soil/Concrete Friction Coeff. Ec : Concrete Elastic Modulus = =Footing base depth below soil surface ft =Allow press. increase per foot of depth ksf = : 11.0Min. Sliding Safety Factor = = Concrete Density = Min Allow % Temp Reinf. ksif'c : Concrete 28 day strength fy : Rebar Yield ksi Min Steel % Bending Reinf. Soil Density =110.0 pcf # Dimensions Width parallel to X-X Axis 4 ft Length parallel to Z-Z Axis = 6.0 ft =Pedestal dimensions... px : parallel to X-X Axis in pz : parallel to Z-Z Axis in Height == in Footing Thickness = 24.0 in= Rebar Centerline to Edge of Concrete... =inat Bottom of footing 3.0 Bottom Reinforcing # Bars parallel to X-X Axis (resisting Z Flexure) Reinforcing Bar Size = 5 Number of Bars = 11 Bars parallel to Z-Z Axis (resisting X Flexure) Reinforcing Bar Size =5 Number of Bars =7 Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer SeparationBars along X-X Axis # Bars required within zone 80.0 % # Bars required on each side of zone 20.0 % General Footing LIC# : KW-06011877, Build:20.25.07.09 Mike Santos (c) ENERCALC, LLC 1982-2025 DESCRIPTION:4x6x2 WSWH Footing Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: Applied Loads 0.280 0.350 D Lr ksf L S P : Column Load OB : Overburden = k W E M-zz V-x = =k V-z k M-xx = k-ft= k-ft H = PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding DESIGN SUMMARY Design OK Governing Load CombinationMin. Ratio Item Applied Capacity PASS 0.3163 Soil Bearing 0.3163 ksf 1.0 ksf +D+Lr about Z-Z axis PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Uplift 0.0 k 0.0 k No Uplift PASS 0.001428 Z Flexure (+X) Bot Tens 0.07467 k-ft/ft 52.282 k-ft/ft +1.20D+1.60Lr PASS 0.001428 Z Flexure (-X) Bot Tens 0.07467 k-ft/ft 52.282 k-ft/ft +1.20D+1.60Lr PASS 0.003362 X Flexure (+Z) Bot Tens 0.1680 k-ft/ft 49.968 k-ft/ft +1.20D+1.60Lr PASS 0.003362 X Flexure (-Z) Bot Tens 0.1680 k-ft/ft 49.968 k-ft/ft +1.20D+1.60Lr PASS 0.000433 1-way Shear (+X)0.03556 psi 82.158 psi +1.20D+1.60Lr PASS 0.000433 1-way Shear (-X)0.03556 psi 82.158 psi +1.20D+1.60Lr PASS 0.002272 1-way Shear (+Z)0.1867 psi 82.158 psi +1.20D+1.60Lr PASS 0.002272 1-way Shear (-Z)0.1867 psi 82.158 psi +1.20D+1.60Lr PASS 0.002683 2-way Punching 0.4409 psi 164.317 psi +1.20D+1.60Lr 0.0 Z Flexure (+X) Top Tens 0 k-ft/ft 0.0 k-ft/ft 0.0 Z Flexure (-X) Top Tens 0 k-ft/ft 0.0 k-ft/ft 0.0 X Flexure (+Z) Top Tens 0 k-ft/ft 0.0 k-ft/ft 0.0 X Flexure (-Z) Top Tens 0 k-ft/ft 0.0 k-ft/ft PASS PASS PASS PASS Min Steel Z Flexure Bottom in2/ft0.5180.956 0.543 in2/ft n/a Min Steel X Flexure Bottom0.912 0.518 in2/ft 0.568 in2/ft n/a Min Steel Z Flexure Top0.000 0.000 in2/ft 0.000 in2/ft n/a Min Steel X Flexure Top0.000 0.000 in2/ft 0.000 in2/ft n/a PASS PASS PASS PASS Detailed Results Rotation Axis &ZeccXecc Actual Soil Bearing Stress @ Location Actual / Allow Soil Bearing (in)Gross Allowable Bottom, -Z Top, +Z Left, -X Right, +X RatioLoad Combination... X-X, D Only 1.0 n/a0.3017 0.3017 n/a 0.3020.0n/a X-X, +D+Lr 1.0 n/a0.3163 0.3163 n/a 0.3160.0n/a X-X, +D+0.750Lr 1.0 n/a0.3126 0.3126 n/a 0.3130.0n/a X-X, +0.60D 1.0 n/a0.1810 0.1810 n/a 0.1810.0n/a Z-Z, D Only 1.0 0.3017n/a n/a 0.3017 0.302n/a0.0 Z-Z, +D+Lr 1.0 0.3163n/a n/a 0.3163 0.316n/a0.0 Z-Z, +D+0.750Lr 1.0 0.3126n/a n/a 0.3126 0.313n/a0.0 Z-Z, +0.60D 1.0 0.1810n/a n/a 0.1810 0.181n/a0.0 Rotation Axis & Overturning Stability Load Combination...StatusOverturning Moment Resisting Moment Stability Ratio Footing Has NO Overturning Force Application Axis Sliding Stability All units k Load Combination...StatusSliding Force Resisting Force Stability Ratio Footing Has NO Sliding General Footing LIC# : KW-06011877, Build:20.25.07.09 Mike Santos (c) ENERCALC, LLC 1982-2025 DESCRIPTION:4x6x2 WSWH Footing Project File: 2121 lewis.ec6 Project Title: Engineer: Project ID: Project Descr: Flexure Axis & Load Combination in^2 in^2 in^2 k-ft As Req'd Footing Tension on Bottom Tension k-ft Actual As StatusMuSide Surface Gvrn. As Phi*Mn X-X, +1.40D 0.07350 +Z Bottom 0.5184 ACI 7.6.1.1 0.5425 49.968 OK X-X, +1.40D 0.07350 -Z Bottom 0.5184 ACI 7.6.1.1 0.5425 49.968 OK X-X, +1.20D+0.50Lr 0.09581 +Z Bottom 0.5184 ACI 7.6.1.1 0.5425 49.968 OK X-X, +1.20D+0.50Lr 0.09581 -Z Bottom 0.5184 ACI 7.6.1.1 0.5425 49.968 OK X-X, +1.20D 0.0630 +Z Bottom 0.5184 ACI 7.6.1.1 0.5425 49.968 OK X-X, +1.20D 0.0630 -Z Bottom 0.5184 ACI 7.6.1.1 0.5425 49.968 OK X-X, +1.20D+1.60Lr 0.1680 +Z Bottom 0.5184 ACI 7.6.1.1 0.5425 49.968 OK X-X, +1.20D+1.60Lr 0.1680 -Z Bottom 0.5184 ACI 7.6.1.1 0.5425 49.968 OK X-X, +0.90D 0.04725 +Z Bottom 0.5184 ACI 7.6.1.1 0.5425 49.968 OK X-X, +0.90D 0.04725 -Z Bottom 0.5184 ACI 7.6.1.1 0.5425 49.968 OK Z-Z, +1.40D 0.03267 -X Bottom 0.5184 ACI 7.6.1.1 0.5683 52.282 OK Z-Z, +1.40D 0.03267 +X Bottom 0.5184 ACI 7.6.1.1 0.5683 52.282 OK Z-Z, +1.20D+0.50Lr 0.04258 -X Bottom 0.5184 ACI 7.6.1.1 0.5683 52.282 OK Z-Z, +1.20D+0.50Lr 0.04258 +X Bottom 0.5184 ACI 7.6.1.1 0.5683 52.282 OK Z-Z, +1.20D 0.0280 -X Bottom 0.5184 ACI 7.6.1.1 0.5683 52.282 OK Z-Z, +1.20D 0.0280 +X Bottom 0.5184 ACI 7.6.1.1 0.5683 52.282 OK Z-Z, +1.20D+1.60Lr 0.07467 -X Bottom 0.5184 ACI 7.6.1.1 0.5683 52.282 OK Z-Z, +1.20D+1.60Lr 0.07467 +X Bottom 0.5184 ACI 7.6.1.1 0.5683 52.282 OK Z-Z, +0.90D 0.0210 -X Bottom 0.5184 ACI 7.6.1.1 0.5683 52.282 OK Z-Z, +0.90D 0.0210 +X Bottom 0.5184 ACI 7.6.1.1 0.5683 52.282 OK One Way Shear X Vu @ +XLoad Combination...Vu @ -X Vu:Max Vu / Phi*VnPhi Vn Status +1.40D 0.02 0.02 0.08 82.16 0.00psipsipsipsi OK +1.20D+0.50Lr 0.02 0.02 0.11 82.16 0.00psipsipsipsi OK +1.20D 0.01 0.01 0.07 82.16 0.00psipsipsipsi OK +1.20D+1.60Lr 0.04 0.04 0.19 82.16 0.00psipsipsipsi OK +0.90D 0.01 0.01 0.05 82.16 0.00psipsipsipsi OK One Way Shear Z Load Combination...Vu @ -Z Vu @ +Z Vu:Max Vu / Phi*VnPhi Vn Status +1.40D 0.08 0.08 0.08 82.16 0.00psipsipsipsi OK +1.20D+0.50Lr 0.11 0.11 0.11 82.16 0.00psipsipsipsi OK +1.20D 0.07 0.07 0.07 82.16 0.00psipsipsipsi OK +1.20D+1.60Lr 0.19 0.19 0.19 82.16 0.00psipsipsipsi OK +0.90D 0.05 0.05 0.05 82.16 0.00psipsipsipsi OK Vu / Phi*Vn Two-Way "Punching" Shear All units k StatusVuPhi*VnLoad Combination... +1.40D 0.19 164.32 0.00 OKpsipsi +1.20D+0.50Lr 0.25 164.32 0.00 OKpsipsi +1.20D 0.17 164.32 0.00 OKpsipsi +1.20D+1.60Lr 0.44 164.32 0.00 OKpsipsi +0.90D 0.12 164.32 0.00 OKpsipsi N nam SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org INTERIM CITY MANAGER Tom Hatch CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall March 18, 2024 Also sent via email to: dave@goodwinconsultinggroup.net Linh Le and David Freudenberger 2121 North Lewis Street Santa Ana, CA 92706 Subject: Address Assignment for a Detached Accessory Dwelling Unit located at 2121 North Lewis Street (APN: 101-561-19) in Santa Ana, CA Dear Linh and David, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a 800-square-foot ADU located at 2121 North Lewis Street (APN: 101-561-19). Notice is hereby given that the following assigned address shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address to be Activated/Posted To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 664-2753 or by email at PRaj@santa-ana.org. Sincerely, Punkaj Raj Planning Technician Exhibit A – Address Plan Address Letter for 2121 North Lewis Street Page 2 of 2 c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Mishele Richards, Orange County Fire Authority, GEO Files Coordinator Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager 2121 N LEWIS ST. (E) PRIMARY DWELLING (E) GARAGE 2121 N LEWIS ST. UNIT 2 (N) ADU 2121 N LEWIS ST. (E) PRIMARY DWELLING (E) GARAGE 2121 N LEWIS ST. UNIT 2 (N) ADU EXHIBIT A : ADDRESS PLAN N Page 1 of 1 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2022 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 Rigid Conduit Service Entrance Conductor Riser Underground Service Lateral METER Rev. 1/21/2020 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org SOILS REPORT EXEMPTIONS PCC-06 A. REFERENCES 2022 California Building Code (CBC), Section 1803 for Geotechnical Investigations B. SOILS REPORT REQUIRED Soils reports prepared by a California registered geotechnical engineer shall be provided in accordance with code requirements in Chapter 18 of the current CBC. Two copies of the soils report that are stamped and signed by the geotechnical engineer shall be provided at the time of plan submittal. Exemptions: A soils report will not be required for the following: 1. Accessory structures to an existing single family dwelling such as patio covers and carports 2. Light standards where the height is 25 feet or less 3. Fences and blockwalls where the height is 10 feet or less 4. Retaining walls retaining 6 feet or less of level grade, not supporting surcharge 5. The following types of buildings complying with the “Minimum Foundation Construction Requirements” in Section C below are met: a. Detached one-story garage serving a single family dwelling b. One-story and two-story attached additions to an existing single family dwelling c. New detached one-story accessory dwelling units (ADU) with a maximum building area of 750 sq. ft. The building official reserves the right to require a soils report for any project where questionable soil or slope instability conditions at the site warrant a foundation and soils investigation. C. MINIMUM FOUNDATION CONSTRUCTION REQUIREMENTS UNDER EXEMPTION #5 ABOVE 1. Depth of foundations below the natural grade shall not be less than 18 inches. 2. Continuous foundations shall be reinforced with at least four continuous #4 reinforcing bars, two #4 bars at the top and two #4 bars at the bottom. 3. Slab construction shall be minimum 4” thick, reinforced with #4 bars at 18” on center each way. 4. Doweling of the new foundations and slabs into the existing foundations and slabs shall be required. Dowels shall be a minimum of 6” into the existing concrete and shall extend a minimum of 24” into the new concrete. Dowels shall be minimum #3 bars at 18” on center or #4 bars at 24” on center.