HomeMy WebLinkAbout2017 N Greenleaf St Unit #2 - PlanDR A W I N G D A T E : Au g 1 8 , 2 0 2 5 ( 1 : 2 7 P M ) SHEET #: JO B A D D R E S S : 20 1 7 G R E E N L E A F S T . SA N T A A N A , C A 9 2 7 0 6 NO . RE V I S I O N : DA T E : B Y : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N AT T A C H E D G A R A G E CO N V E R S I O N I N T O AD U SSDSTA N D L E Y S T R U C T U R A L D E S I G N CIVI L - S T R U C T U R A L E N G I N E E R S Located at: 18757 BURBANK BLVD. UNIT 109 TARZANA, CA 91356 Call: (213) 373-4513 A. G . A. G . PR O J E C T I N F O . A-1 2017 GREENLEAF ST SANTA ANA, CA 92706 VICINITY MAP SCOPE OF WORK CONVERTING 546 SQ. FT. OF THE ATTACHED GARAGE INTO ADU PROJECT NAME: 2017 GREENLEAF ST SANTA ANA, CA 92706 NOT TO SCALE PROJECT TEAM OWNER CONTRACTOR DESIGNER SOILS/SURVEYOR TITLE-24 ATTACHED GARAGE CONVERSION INTO ADU CODES -2022 CALIFORNIA BUILDING CODE (CBC) -2022 CALIFORNIA RESIDENTIAL CODE (CRC) -2022 CALIFORNIA MECHANICAL CODE (CMC) -2022 CALIFORNIA ELECTRICAL CODE (CEC) -2022 CALIFORNIA PLUMBING CODE (CPC) -2022 CALIFORNIA ENERGY CODE -2022 CALIFORNIA GREEN BUILDING STANDARDS CODE CRAIG STANDLEY (LIC.. #87675) 17940 VENTURA BLVD., ENCINO, CA 91316 P: 213-373-4513 E: CRAIG@STANDLEYSTRUCTURAL.COM LEGAL DESCRIPTION: ASSESSOR PARCEL NO.002-103-12 TRACT LOT NO. BLOCK BASELINE HILLSIDE ORDINANCE TYPE OF CONSTRUCTION ZONING NO. OF STORIES SEC 1 T 5 R 10 PARKING 12 N/A NO TYPE-VB R-1 1 SEE SITE PLAN SHEET INDEX A-1 PROJECT INFO. A-2 A-3 A-4 S-1 S-2 SD1 SITE PLAN / ROOF PLAN FLOOR PLANS ELEVATIONS / SECTION FOUNDATION PLAN STRUCTURAL DETAILS STRUCTURAL NOTES AREA CALCULATIONS 1,532 SQ. FT.EXISTING SINGLE-FAMILY DWELLING 546 SQ. FT. FLOOR AREA RATIO 2,078 / 8,552.59 = 24.29% LOT COVERAGE NO CHANGE EXISTING GARAGE INTO ADU TOTAL 2,078 SQ. FT. OCCUPANCY R-3 / U NEAREST BUS STOP SSW1 SIMPSON STRUCTURAL DETAILS SSW2 SIMPSON STRUCTURAL DETAILS LOT SIZE 8,552.59 SQ. FT. A-5 TITLE-24 FORMS ADU / EXISTING FLOOR RATIO 546 / 1,532 = 35.63% A-6 MANDATORY MEASURES PL PL PL PL PL PL PL PL PL PL PL PL PLPLPLPLPLPLPLPL GR E E N L E A F S T R E E T PROPERTY LINE:168.40' PR O P E R T Y L I N E : 4 8 . 8 7 ' PROPERTY LINE:168.40' PR O P E R T Y L I N E : 4 8 . 8 7 ' (E) DRIVEWAY UNIT 1 (E) SINGLE FAMILY DWELLING 2017 GREENLEAF STREET 13 ' - 8 " 10 ' - 9 " 41'-7" EXISTING UN-PERMITTED PATIO COVER TO BE DEMOLISHED (E) 5' TALL CMU WALL TO REMAIN (E) 5' TALL CMU WALL TO REMAIN RE Q U I R E D S I D E Y A R D S E T B A C K : 4 ' - 0 " 37'-3" 9' - 2 " 13 ' - 1 " 52'-0" 84'-11" 2' - 1 1 " 8'-7" (E) COVERED PATIO (E) 5' TALL FENCE(E) DROUGHT TOLERANT LANDSCAPING TO REMAIN (E) 3' TALL CMU WALL TO REMAIN (E) 3' TALL CMU WALL TO REMAIN (N) TANKLESS WATER HEATER UNIT 2 (E) GARAGE CONVERSION INTO ADU (546 SQ. FT.) NEW PEDESTRIAN PATHWAY TO STREET 5' - 0 " 3' - 8 " 3'-0" (E) ROOF 14" PER FT. (E) RO O F 14" PER F T . (E) SCUPPER (E) ROOF 14" PER FT. DR A W I N G D A T E : A u g 1 8 , 2 0 2 5 ( 1 : 2 8 P M ) SHEET #: JO B A D D R E S S : 20 1 7 G R E E N L E A F S T . SA N T A A N A , C A 9 2 7 0 6 NO . RE V I S I O N : DA T E : B Y : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N AT T A C H E D G A R A G E CO N V E R S I O N I N T O AD U SSDSTA N D L E Y S T R U C T U R A L D E S I G N CIVI L - S T R U C T U R A L E N G I N E E R S Located at: 18757 BURBANK BLVD. UNIT 109 TARZANA, CA 91356 Call: (213) 373-4513 A. G . A. G . SI T E P L A N / RO O F P L A N A-2 SITE PLAN (PROPOSED) SHOWING AREA OF WORK SCALE: 1/8"=1'-0" GENERAL NOTES: 1.SMOKE DETECTORS SHALL BE PROVIDED IN EACH SLEEPING ROOM, ON THE CEILING OR WALL IMMEDIATELY OUTSIDE OF EACH SLEEPING ROOM, AND ON EACH STORY AND BASEMENT FOR DWELLINGS WITH MORE THAN ONE STORY (907.2.11.2, R314.3) 2. THE POWER SOURCE FOR SMOKE DETECTORS SHALL BE AS FOLLOWS: A. IN NEW CONSTRUCTION SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACKUP B. IN EXISTING SFD, SMOKE DETECTORS MAY BE BATTERY OPERATED C. CARBON MONOXIDE ALARM IS REQUIRED PER SEC. 420.4 & R315 3. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PILL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 4. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 171, 874) (SEPARATE PLUMBING PERMIT IS REQUIRED). 5. PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. 6. AN APPROVED CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLICATIONS ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. CARBON MONOXIDE DETECTORS SHALL BE PROVIDED OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S0 AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. (R315) 7. ARCHITECTURAL PAINTS AND COATINGS, ADHESIVES, CAULKS AND SEALANTS SHALL COMPLY WITH THE VOLATILE ORGANIC COMPOUND (VOC) LIMITS LISTED IN TABLES 4.504.1-4.504.3 8. THE APPROVAL OF PLANS AND SPECIFICATIONS DOES NOT PERMIT THE VIOLATION OF ANY SECTION OF THE BUILDING CODE OR OTHER CITY ORDINANCE OR STATE LAWS. 9. WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS, OR ADDITIONS EXCEEDING ONE THOUSAND DOLLARS ($1,000), EXISTING DWELLING OR SLEEPING UNITS THAT HAVE ATTACHED GARAGES OR FUEL-BURNING APPLIANCES SHALL BE PROVIDED WITH A CARBON MONOXIDE DETECTOR IN ACCORDANCE WITH SECTION R315.1. CARBON MONOXIDE DETECTORS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. (R315.2) 10.EFFECTIVE JAN. 1, 201, SB 407 REQUIRES REPLACEMENT OF ALL NONCOMPLIANT PLUMBING FIXTURES IN PROPERTIES BUILT ON OR BEFORE JAN. 1, 2994 WITH WATER CONSERVING PLUMBING FIXTURES 11.SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, UPON THE OWNER'S APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS, OR ADDITIONS, EXCEEDING ONE THOUSAND DOLLARS ($1,000) (R314.6.2) 12.AN OPERATION AND MAINTEANCE MANUAL INCLUDING AT A MINIMUM, THE ITEMS LISTED IN SECTION 4.410.1 SHALL BE COMPLETED AND PLACED IN THE BUILDING AT THE TIME OF FINAL INSPECTION 13.WATER HEATER MUST BE STRAPPED TO WALL. 15.UNIT SKYLIGHTS SHALL BE LABELED BY A LA CITY APPROVED LABELING AGENCY. SUCH LABEL SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND PERFORMANCE GRADE RATING (RESEARCH REPORT NOT REQUIRED) 16.FOR EXISTING POOL ON SITE, PROVIDE AN ALARM FOR DOORS TO THE DWELLING THAT FORM A PART OF THE POOL ENCLOSURE. THE ALARM SHALL SOUND CONTINUOUSLY FOR A MIN. OF 30 SECONDS WHEN THE DOOR IS OPENED. IT SHALL AUTOMATICALLY RESET AND BE EQUIPPED WITH WITH A MANUAL MEANS TO DEACTIVATE (FOR 15 SECS. MAX.) FOR A SINGLE OPENING. THE DEACTIVATION SWITCH SHALL BE AT LEAST 54" ABOVE THE FLOOR 17.FOR EXISTING POOL ON SITE, PROVIDE ANTI-ENTRAPMENT COVER MEETING THE CURRENT ASTM OR SME FOR THE SUCTION OUTLETS OF THE SWIMMING POOL, TODDLER POOL, AND SPA FOR SINGLE FAMILY DWELLINGS. 18.AUTOMATIC GARAGE DOOR OPENERS IF PROVIDED SHALL BE LISTED IN ACCORDANCE WITH UL 325 19.EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 6 FOOT CANDLES OVER THE AREA OF THE ROOM AT HEIGHT OF 30 INCHES ABOVE FLOOR LEVEL 20.A COPY OF THE RESEARCH REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE 21.CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE LADBS INSPECTORS AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER SEC 1706.1 22.WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS, OR ADDITIONS EXCEEDING ONE THOUSAND DOLLARS ($1,000), EXISTING DWELLING OR SLEEPING UNITS THAT HAVE ATTACHED GARAGES OR FUEL-BURNING APPLIANCES SHALL BE PROVIDED WITH A CARBON MONOXIDE DETECTOR IN ACCORDANCE WITH SECTION R315.1. CARBON MONOXIDE DETECTORS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. (R315.2) 23.SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, UPON THE OWNER'S APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS, OR ADDITIONS, EXCEEDING ONE THOUSAND DOLLARS ($1,000) (R314.6.2) NOTE: UTILITIES TO BE UNDERGROUND PER SAMC SECTION 41-626 NOTE: NO EXISTING EASEMENTS ONSITE (E) ROOF PLAN (NO CHANGE) SHOWING AREA OF WORK SCALE: 1/4"=1'-0" (N) SLEEPING AREA (N) BATH SFD GARAGE PL PL PL PL PL PL PL SFD PL PL PL PL PL PL PL (N) KITCHEN AREA 18'-11"13'-4" 5' - 0 " 8'-0" 13 ' - 0 " 8'-0" 5' - 4 " 40'-11" 13 ' - 0 " HALL 18'-0" 8' - 0 " 18'-0" 3' - 6 " 3'-0" 3' - 0 " 6'-0" CLOSET 10 ' - 5 " 8' - 0 " 15" MIN.15" MIN. 24 " M I N . (N) LIVING AREA(N) ENTRY W/D EXISTING UN-PERMITTED PATIO COVER TO BE DEMOLISHED 41'-7" 13 ' - 8 " 10'-0" 3'-0" 3' - 0 " (N) GAS STOVE (N) GAS DRYER (N) GAS TANKLESS WATERHEATER A A-4 A A-4 B -- (N) DINING AREA 2 -- 1 -- (N) DUCTLESS MINI-SPLIT HANDLER (N) DUCTLESS MINI-SPLIT HANDLER NOTE: AT LEAST ONE LEAF TO HAVE 32" MIN. CLEAR OPENING PER 2018 IBC SECTION 1010.1.5 EXCEPTION 1.1.1: "DOORS SERVING INDIVIDUAL DWELLING UNITS IN GROUPS R-2 AND R-3. A DOOR IS PERMITTED TO OPEN AT THE TOP STEP OF AN INTERIOR FLIGHT OF STAIRS, PROVIDED THAT THE DOOR DOES NOT SWUNG OVER THE TOP STEP. HALL 5'-6" (N) LANDING 12" THRESHOLD (N) DOOR(N) 2"X4" STUD WALL PER PLAN 3'-0" 6" 11" MAX RISE: 7 34" MIN. RUN: 11" 2 2X STUDS @ 16" O.C., TYP. 58" TYPE "X" GYP. BOARD RESILIENT CHANNEL @ 16" O.C. INSTALL ON EACH STUD 1. THE TYPE AND SPACING OF RESILIENT CHANNELS AND CLIPS AND THE ATTACHENT OF GYPSUM BOARD OR LATH SHALL BE AS REQUIRED FOR FIRE RATINGS. 2. THE MINERAL FIBER INSULATION SHALL HAVE ATHERMAL RESISTANCE R VALUE OF 11 OR GREATER AS DETERMINED BY FEDERAL SPECIFICATION RR-I-521B 1 HR FIRED / STC 50 WALL ASSEMBLY1 STRUC. I PLY PER PLAN SEE STRUCT. PLANS R-15 INSULATION PER PLAN 2X STUDS @ 16" O.C., TYP. 58" TYPE "X" GYP. BOARD RESILIENT CHANNEL @ 16" O.C. INSTALL ON EACH STUD 78" STUCCO 1. THE TYPE AND SPACING OF RESILIENT CHANNELS AND CLIPS AND THE ATTACHENT OF GYPSUM BOARD OR LATH SHALL BE AS REQUIRED FOR FIRE RATINGS. 2. THE MINERAL FIBER INSULATION SHALL HAVE ATHERMAL RESISTANCE R VALUE OF 11 OR GREATER AS DETERMINED BY FEDERAL SPECIFICATION RR-I-521B 1 HR FIRED / STC 50 WALL ASSEMBLY STRUC. I PLY PER PLAN SEE STRUCT. PLANS R-15 INSULATION PER PLAN 58" TYPE "X" GYP. BOARD DR A W I N G D A T E : S e p 1 1 , 2 0 2 5 ( 1 0 : 1 3 A M ) SHEET #: JO B A D D R E S S : 20 1 7 G R E E N L E A F S T . SA N T A A N A , C A 9 2 7 0 6 NO . RE V I S I O N : DA T E : B Y : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N AT T A C H E D G A R A G E CO N V E R S I O N I N T O AD U SSDSTA N D L E Y S T R U C T U R A L D E S I G N CIVI L - S T R U C T U R A L E N G I N E E R S Located at: 18757 BURBANK BLVD. UNIT 109 TARZANA, CA 91356 Call: (213) 373-4513 A. G . A. G . A-3 GREEN NOTES 1. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES,, CONDUITS, OR OTHER OPENINGS IN THE BUILDINGS ENVELOPE AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY, OR METAL PLATES. 2. FOR ALL NEW EQUIPMENT, AN OPERATION AND MAINTENANCE MANUAL INCLUDING, AT A MINIMUM THE ITEMS LISTED IN SECTION 4.410.1, SHALL BE COMPLETED AND PLACED IN THE BUILDING AT THE TIME OF FINAL INSPECTION 3. ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL SARTUP OF THE HEATING, COOLING AND VENT. EQUIPMENT 4. THE VOC CONTENT VERIFICATION CHECKLIST SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURERS SPECIFICATIONS SHOWING VOC CONTENT FOR ALL APPLICABLE PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION 5. ALL NEW CARPET AND CARPET CUSHIONS INSTALLE DIN THE BUILDING INTERIOR SHALL MEET THE TESTING PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING 1. CARPET AND RUG INSTITUTES GREEN LABEL PLUS PROGRAM 2. CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 3. NSF/ANSI 140 AT THE GOLD LEVEL 4. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE 6. 80% OF THE TOTAL AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING 1. VOC EMISSION LIMITS DEFINED IN THE CHPS HIGH PERFORMANCE PRODUCTS DATABASE 2. CERTIFIED UNDER UL GREENGUARD GOLD 3. CERTIFICATION UNDER THE RESILIENT FLOOR COVERING INSTITUTE 4. MEET THE CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 7. THE HEATING AND AIR CONDITIONING SYSTEMS SHALL BE SIZED AND DESIGNED USING ANSI/ACCA MANUAL J-2004, ANSI/ACCA 29-D-2009 OR ASHRAE HANDBOOKS AND HAVE THEIR EQUIPMENT SELECTED IUN ACCORDANCE WITH ANSI/ACCA 36-S MANUAL S-2004 8. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80psi, OR THE SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN OPERATION AT A TIME 9. THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES IN SECTION 4.303.1 10.THE HOT WATER SYSTEM SHALL NOT ALLOW MORE THAN 0.6 GALLONS OF WATER TO BE DELIVERED TO ANY FIXTURES BEFORE HOT WATER ARRIVES OR SHALL COMPLY WITH EITHER LOS ANGELES PLUMBING CODE SECTION 610.4.1.2 OR 610.4.1.3 #SIZE(WXH)DESCRIPTION REMARKS WINDOW SCHEDULE 1 8'-0" x 3'-0" SLIDER XOX #SIZE (WXH)DESCRIPTION REMARKS DOOR SCHEDULE 1 SINGLE-HINGED 2 3'-0" x 6'-8"SINGLE-HINGED 3 6'-0" x 6'-8"FRENCH DOOR MECHANICAL 1. GROUND FAULT CIRCUIT-INTERRUPTION (GFCI) FOR PERSONNEL SHALL BE RPOVIDED AND INSTALLED IN READILY ACCESSIBLE AREA 2. ARC-FAULT CIRCUIT INTERRUPTION SHALL BE INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT 3. TAMPER-RESISTANT RECEPTACLES SHALL BE INSTALLED IN ALL AREAS SPECIFIED IN 210.52, ALL NONLOCKING TYPE 12-VOLT; 15- AND 20-AMPERE RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT PLUMBING 1. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL SYSTEM 2. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY 3. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR 4. PROVIDE ULTRA FLUSH WATER CLOSET FOR ALL NEW CONSTRUCTION, EXISTING SHOWERHEADS AND TOILETS MUST BE ADOPTED FOR LOW WATER CONSUMPTION 5. MECHANICAL, ELECTRICAL, AND PLUMBING PLANS ARE NOT REVIEWED AND ARE SUBJECT TO FIELD INSPECTION 6. THE FLOW RATES FOR ALL NEW PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES SPECIFIED IN SECTION 4.303.1 EXISTING FLOOR PLAN/DEMO PLAN SHOWING AREA OF WORK SCALE: 1/4"=1'-0" FL O O R P L A N S LEGEND: EXISTING WALLS: NEW WALLS: 2X4 @ 16" O.C. (USE 2X6 @ 16" O.C. FOR WALLS > 10'-0" IN HT. WALLS TO REMOVE: SMOKE DETECTOR: (WIRED W/ BATTERY BACK UP) CARBON MONOXIDE ALARM: (HARD-WIRED W/ BATTERY BACKUP) EXHAUST FAN (MIN. 50 CFM) (DUCTED TO OUTSIDE OF BUILDING)(ENERGY STAR W/ HUMIDISTAT) SD CO PROPOSED FLOOR PLAN SHOWING AREA OF WORK SCALE: 1/4"=1'-0" U-FACTOR SHGC 0.30 0.23 4 2'-8" x 6'-8"POCKET DOOR 2'-8" x 6'-8" 3 2 2 TEMPERED SD CO 1 HR FIRE RATED EXTERIOR WALL PER DETAIL #1 1 HR FIRE RATED INTERIOR WALL PER DETAIL #2 KITCHEN EXHAUST FAN (MIN. 100 CFM) (DUCTED TO OUTSIDE OF BUILDING)(ENERGY STAR W/ HUMIDISTAT) SD 5 8'-0" x 6'-8"FRENCH DOOR 0.30 0.23 5 6 4'-0" x 6'-8"DBL. DOOR NOTE: WINDOWS STYLE, MATERIAL AND COLOR TO MATCH EXISTING SINGLE-FAMILY DWELLING. U-FACTOR SHGC 0.230.30 MATERIAL TO MATCH EXISTING SINGLE-FAMILY DWELLING COLOR BLACK SECTION VIEW SHOWING AREA OF WORK SCALE: 3/8"=1'-0"B TEMPERED TEMPERED (N) BATH (N) BATH (N) FUTURE W/D OR WATER HEATER SFD PL PL PL PL PL PL PL (N) LIVING AREA (N) KITCHEN AREA 40'-11" 8'-0" 13 ' - 0 " 15" MIN.15" MIN. 15 " M I N . 3' - 6 " 3'-0" 3' - 0 " 6'-0" 10 ' - 5 " 2' - 5 " (N) CLOSET 7' - 8 " 6'-11" 2'-10"8'-6" 5' - 0 " SFD PL PL PL PL PL PL PL (N) LIVING AREA (N) KITCHEN AREA 8'-0" 8'-0" 5' - 4 " 3' - 6 " 3'-0" 3' - 0 " 6'-0" 11'-8" 15" MIN.15" MIN. 24 " M I N . 10 ' - 5 " 8' - 0 " (N) SLEEPING AREA (N) CLOSET 13'-4"18'-11" 13 ' - 0 " 7'-3" 4' - 6 " 4' - 0 " 4' - 6 " 2' - 0 " 5' - 0 " 5'-6"15'-10" (N) ENTRY (N) SLEEPING AREA (N) ENTRY #SIZE(WXH)DESCRIPTION REMARKS WINDOW SCHEDULE 1 8'-0" x 3'-0"SLIDER XOX #SIZE (WXH)DESCRIPTION REMARKS DOOR SCHEDULE 1 SINGLE-HINGED 2 3'-0" x 6'-8"SINGLE-HINGED 3 6'-0" x 6'-8"FRENCH DOOR MECHANICAL 1. GROUND FAULT CIRCUIT-INTERRUPTION (GFCI) FOR PERSONNEL SHALL BE RPOVIDED AND INSTALLED IN READILY ACCESSIBLE AREA 2. ARC-FAULT CIRCUIT INTERRUPTION SHALL BE INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT 3. TAMPER-RESISTANT RECEPTACLES SHALL BE INSTALLED IN ALL AREAS SPECIFIED IN 210.52, ALL NONLOCKING TYPE 12-VOLT; 15- AND 20-AMPERE RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT PLUMBING 1. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL SYSTEM 2. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY 3. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR 4. PROVIDE ULTRA FLUSH WATER CLOSET FOR ALL NEW CONSTRUCTION, EXISTING SHOWERHEADS AND TOILETS MUST BE ADOPTED FOR LOW WATER CONSUMPTION 5. MECHANICAL, ELECTRICAL, AND PLUMBING PLANS ARE NOT REVIEWED AND ARE SUBJECT TO FIELD INSPECTION 6. THE FLOW RATES FOR ALL NEW PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES SPECIFIED IN SECTION 4.303.1 AL T E R N A T E FL O O R P L A N S LEGEND: EXISTING WALLS: NEW WALLS: 2X4 @ 16" O.C. (USE 2X6 @ 16" O.C. FOR WALLS > 10'-0" IN HT. WALLS TO REMOVE: SMOKE DETECTOR: (WIRED W/ BATTERY BACK UP) CARBON MONOXIDE ALARM: (HARD-WIRED W/ BATTERY BACKUP) EXHAUST FAN (MIN. 50 CFM) (DUCTED TO OUTSIDE OF BUILDING)(ENERGY STAR W/ HUMIDISTAT) SD CO ALTERNATE PROPOSED FLOOR PLAN "B" SHOWING AREA OF WORK SCALE: 1/4"=1'-0" U-FACTOR SHGC 0.30 0.23 4 2'-8" x 6'-8"POCKET DOOR 2'-8" x 6'-8" DR A W I N G D A T E : M a r 2 0 , 2 0 2 5 ( 1 1 : 1 7 A M ) SHEET #: JO B A D D R E S S : 20 1 7 G R E E N L E A F S T . SA N T A A N A , C A 9 2 7 0 6 NO . RE V I S I O N : DA T E : B Y : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N AT T A C H E D G A R A G E CO N V E R S I O N I N T O AD U SSDSTA N D L E Y S T R U C T U R A L D E S I G N CIVI L - S T R U C T U R A L E N G I N E E R S Located at: 18757 BURBANK BLVD. UNIT 109 TARZANA, CA 91356 Call: (213) 373-4513 A. G . A. G . A-3.1 GREEN NOTES 1. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES,, CONDUITS, OR OTHER OPENINGS IN THE BUILDINGS ENVELOPE AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY, OR METAL PLATES. 2. FOR ALL NEW EQUIPMENT, AN OPERATION AND MAINTENANCE MANUAL INCLUDING, AT A MINIMUM THE ITEMS LISTED IN SECTION 4.410.1, SHALL BE COMPLETED AND PLACED IN THE BUILDING AT THE TIME OF FINAL INSPECTION 3. ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL SARTUP OF THE HEATING, COOLING AND VENT. EQUIPMENT 4. THE VOC CONTENT VERIFICATION CHECKLIST SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURERS SPECIFICATIONS SHOWING VOC CONTENT FOR ALL APPLICABLE PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION 5. ALL NEW CARPET AND CARPET CUSHIONS INSTALLE DIN THE BUILDING INTERIOR SHALL MEET THE TESTING PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING 1. CARPET AND RUG INSTITUTES GREEN LABEL PLUS PROGRAM 2. CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 3. NSF/ANSI 140 AT THE GOLD LEVEL 4. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE 6. 80% OF THE TOTAL AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING 1. VOC EMISSION LIMITS DEFINED IN THE CHPS HIGH PERFORMANCE PRODUCTS DATABASE 2. CERTIFIED UNDER UL GREENGUARD GOLD 3. CERTIFICATION UNDER THE RESILIENT FLOOR COVERING INSTITUTE 4. MEET THE CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 7. THE HEATING AND AIR CONDITIONING SYSTEMS SHALL BE SIZED AND DESIGNED USING ANSI/ACCA MANUAL J-2004, ANSI/ACCA 29-D-2009 OR ASHRAE HANDBOOKS AND HAVE THEIR EQUIPMENT SELECTED IUN ACCORDANCE WITH ANSI/ACCA 36-S MANUAL S-2004 8. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80psi, OR THE SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN OPERATION AT A TIME 9. THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES IN SECTION 4.303.1 10.THE HOT WATER SYSTEM SHALL NOT ALLOW MORE THAN 0.6 GALLONS OF WATER TO BE DELIVERED TO ANY FIXTURES BEFORE HOT WATER ARRIVES OR SHALL COMPLY WITH EITHER LOS ANGELES PLUMBING CODE SECTION 610.4.1.2 OR 610.4.1.3 TEMPERED 1 HR FIRE RATED WALL PER DETAIL #1 KITCHEN EXHAUST FAN (MIN. 100 CFM) (DUCTED TO OUTSIDE OF BUILDING)(ENERGY STAR W/ HUMIDISTAT) ENTRY DOOR 5 8'-0" x 6'-8"FRENCH DOOR 0.30 0.23 6 4'-0" x 6'-8"DBL. DOOR ALTERNATE PROPOSED FLOOR PLAN "A" SHOWING AREA OF WORK SCALE: 1/4"=1'-0" 8' - 8 " 2' - 0 " 11 ' - 1 0 " 8' - 8 " 2' - 0 " 11 ' - 1 0 " 8' - 8 " 2' - 0 " 11 ' - 6 " (N) R-13 BATT. INSULATION (N) R-30 BATT. INSULATION (E) 2X4 WALL TO REMAIN (E) ROOF RAFTER TO REMAIN (N) JADU (N) R-13 BATT. INSULATION (E) 2X4 WALL TO REMAIN 8' - 8 " (E) SLAB ON GRADE WITH MIN. 3 COATS OF CONCRETE FLOOR MOISTURE RETARDANT BARRIER (SEE FOUNDATION PLAN) PL PL 8' - 8 " 2' - 0 " 11 ' - 1 0 " ⅊ 7' - 8 " 7' - 0 " 7' - 7 " 7' - 8 " (E) PVC MEMBRANE ROOFING TO REMAIN 8' - 0 " F.F.F.G. F.F.F.G. F.F.F.G. F.F.F.G. 4" 4" 4" 4" DR A W I N G D A T E : A u g 1 8 , 2 0 2 5 ( 1 : 2 8 P M ) SHEET #: JO B A D D R E S S : 20 1 7 G R E E N L E A F S T . SA N T A A N A , C A 9 2 7 0 6 NO . RE V I S I O N : DA T E : B Y : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N AT T A C H E D G A R A G E CO N V E R S I O N I N T O AD U SSDSTA N D L E Y S T R U C T U R A L D E S I G N CIVI L - S T R U C T U R A L E N G I N E E R S Located at: 18757 BURBANK BLVD. UNIT 109 TARZANA, CA 91356 Call: (213) 373-4513 A. G . A. G . A-4 EL E V A T I O N S / S E C T I O N SOUTH ELEVATION VIEW SHOWING AREA OF WORK SCALE: 3/8"=1'-0" CertaFlash flex Flashing beyond Installed window CertainTeed Restoration Millwork trim board "Z" flashing, extending 1" each side. 2" vertical leg recommended. Weather resistance barrier Shim as required TYPICAL WINDOW FLASHING1 ARCH KEY NOTES: 1 CTS RAPID SET ONE COAT STUCCO SYSTEM (LARR# 25358, ESR-2671) OR EQUIV. TO MATCH EXISTING NORTH ELEVATION VIEW SHOWING AREA OF WORK SCALE: 3/8"=1'-0" EAST ELEVATION VIEW SHOWING AREA OF WORK SCALE: 3/8"=1'-0" SECTION VIEW SHOWING AREA OF WORK SCALE: 3/8"=1'-0"A WEEP SCREED DETAIL2 STUD WALL PER PLAN MIN. 2" ABOVE PAVED MIN. 4" ABOVE GRADE WALL SHEATHING 2 LAYERS OF GRADE D PAPER STUCCO WEEP SCREEN FOOTING METAL LATH NOTE: EXTERIOR MATERIALS TO MATCH THE PRIMARY RESIDENCE. STUCCO COLOR AND STYLE TO MATCH & WINDOW COLOR, MATERIAL, AND STYLE TO MATCH WEST ELEVATION VIEW SHOWING AREA OF WORK SCALE: 3/8"=1'-0" DR A W I N G D A T E : Ju l 1 6 , 2 0 2 5 ( 4 : 5 4 P M ) SHEET #: JO B A D D R E S S : 20 1 7 G R E E N L E A F S T . SA N T A A N A , C A 9 2 7 0 6 NO . RE V I S I O N : DA T E : B Y : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N AT T A C H E D G A R A G E CO N V E R S I O N I N T O AD U SSDSTA N D L E Y S T R U C T U R A L D E S I G N CIVI L - S T R U C T U R A L E N G I N E E R S Located at: 18757 BURBANK BLVD. UNIT 109 TARZANA, CA 91356 Call: (213) 373-4513 A. G . A. G . ST R U C . N O T E S S-1 Footing, Stem Walls, Piers Stepftg/Retain'g Foundation Caisson, Piles, Grade Beams Firm or individual to be responsilbe for the Structural Observation: STRUCTURAL OBSERVATION PROGRAM to be the Structural Observer. DECLARATION BY OWNER Signature Date Observer is different from the Architect of Engineer of Record) I, the Owner of the project, declare that the above listed firm or individual is hired by me to be the DECLARATION BY ARCHITECT OR ENGINEER OF RECORD I, the Architect or Engineer of record, declare that the above listed firm or individual is designated by me to Hillside Special Anchors Structural Observer. Name: conc beam FOUNDATION Mat Foundation Owner: PROJECT ADDRESS: Description of Work: (required if the Structural FRAME Masonry Wall Frame Steel Braced Frame Steel Moment Frame STRUCTURAL OBSERVATION(only checked items are required) Concrete Moment Frame Phone:(916) 333-9225 WALL Others: Masonry Concrete Wood Others: Architect: Calif. Registration: Steel Deck Others: Wood Concrete DIAPHRAGM PERMIT APPL. NO.: Engineer: AND DESIGNATION OF THESTRUCTURAL OBSERVER Standley Standley C87675 1. MATERIAL DELIVERED TO THE CONSTRUCTION SITE SHALL BE PROTECTED FROM RAIN OR OTHER SOURCES OF MOISTURE. (9.407.4) 2. ALL STUDS, JOISTS, RAFTERS, AND BLOCKING'S SHALL BE DF-L NO. 2 AS GRADED BY WWPGR, ALL POSTS AND BEAMS SHALL DF-L N0. 1 OR BETTER AS GRADED BY WWPGR. UNO. 3. ALL LUMBER IN CONTACT WITH CONCRETE SHALL BE DF-LARCH PRESSURE TREATED. 4. ALL NEW SHEATHING USE FOR BRACING SHALL BE 15/32" CDX, 5-PLY PANEL CONSTRUCTION WITH SPAN RATING OF 32/16 OR BETTER AS RATED BY AMERICAN PLYWOOD ASSOC. 5. ANY NAIL IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE HOT-DIPPED GALVANIZED OR STAINLESS STEEL. 6. BUILDING MATERIAL WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. WALL AND FLOORING FRAMING SHALL NOT BE ENCLOSED UNTIL IT IS INSPECTED AND FOUND TO BE SATISFACTORY BY BUILDING INSPECTOR. (9.505.3) 1. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO STARTING OF WORK. 2. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PILL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF HOOK-UP. 3. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 4. CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR SPRAYED-ON FIREPROOFING AND HIGH LOAD DIAPHRAGMS 5. CONSTRUCTION WASTE WILL BE HANDLED BY CITY OF LOS ANGELES CERTIFIED HAULER AND SHALL BE REDUCED BY 50% OF ITS OVERALL WASTE. CALIFORNIA WASTE SERVICES, PERMIT# PER-09-058 621 W. 152ND ST., GARDENA, CA 90247 1. ALL NON-EPOXY GROUT SHALL BE RAPID SET BRAND OR EQUIV. INSTALLED PER THE MANUFACTURERS SPEC'S, LARR24654. 2. ALL EPOXY TYPE GROUT SHALL BE SIMPSON SET BRAND STRUCTURAL EPOXY OR EQUIV. INSTALLED PER THE MANUFACTURERS SPECIFICATIONS, LA RR#25279. 3. CLEAN OUT ALL DRILLED BORINGS AND CRACKS PRIOR TO APPLICATION OF GROUT. DEPUTY INSPECTION REQUIRED AT ALL TIME OF PROCEDURE. 4. CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR HIGH-LIFT GROUTING. 1. ALL STEEL REINFORCEMENT BARS SHALL BE 60,000 PSI YIELD STRENGTH CONFORMING TO ASTM STD A615, UNLESS NOTED OTHERWISE. 2. ALL STEEL REINFORCEMENT TIES AND STIRRUPS SHALL BE 40,000 PSI YIELD STRENGTH CONFORMING TO ASTM STD A615, UNLESS NOTED OTHERWISE. 3. ALL STEEL REINFORCEMENT HOOKS SHALL BE PER ACI318 STANDARD HOOKS SCHEDULE. 4. ALL BENDS IN REINFORCEMENT BARS SHALL BE MADE COLD. 5. STEEL REINFORCEMENT SHALL BE FREE OF LOOSE FLAKY RUST, MUD, OIL, AND OTHER COATINGS WHICH MAY REDUCE BOND STRENGTH. 6. STEEL REINFORCING SHALL BE ACCURATELY PLACED IN CONCRETE FORMS WITH THE APPROPRIATE CLEAR COVER MAINTAINED. 7. SPLICES IN STEEL REINFORCEMENT FOR SLABS AND RETAINING WALL SHALL BE A MINIMUM OF 40 BAR DIAMETER OR 24 INCHES WHICH EVER IS LARGER. 8. SHOP WELDING FOR STEEL REINFORCEMENT SHALL BE PERFORMED IN A LADBS LICENSED FABRICATION SHOP OR CALIFORNIA LICENSED FABRICATION SHOP. 9. FIELD WELDING FOR STEEL REINFORCEMENT SHALL BE PERFORMED BY A LADBS CERTIFIED WELDERS OR CALIFORNIA LICENSED WELDER. CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING. 1. ALL EXISTING FOUNDATIONS & FOOTINGS SHALL BE CLEANED OFF PRIOR TO POURING OF NEW CONCRETE FOR PROPER BONDING. 2. CEMENT SHALL CONFORM TO THE SPECIFICATION FOR PORTLAND CEMENT ASTM C150. 3. WATER USED IN MIXING CONCRETE SHALL BE CLEAN AND FREE FROM INJURIOUS AMOUNTS OF OILS, ACIDS, ALKALIS, SALTS, ORGANIC MATERIALS, OR OTHER SUBSTANCES THAT MAY BE DELETERIOUS TO CONCRETE OR REINFORCEMENT BARS. 4. ALL CONCRETE WORK SHALL BE DONE WITH MINIMUM OF 3000PSI CONCRETE, UNLESS NOTED OTHERWISE. 5. CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR CONCRETE STRENGTH GREATER THAN 2500 PSI, DRIVEN DEEP FOUNDATION, CAST-IN PLACE DEEP FOUNDATIONS, ENGINEERING MASONRY, PRE-STRESSED CONCRETE, HIGH LOAD DIAPHRAGMS AND SPECIAL MOMENT-RESISTING CONCRETE FRAMES. 6. ALL CONCRETE SHALL BE 3,000 PSI IN 28 DAYS & DEPUTY INSPECTION IS REQUIRED, UNLESS NOTED OTHERWISE. 7. PLACEMENT OF STEEL REINFORCEMENT IN CONCRETE SHALL BE AS FOLLOWED: A. 3 INCHES FROM FACE OF CONCRETE CAST IF IT IS AGAINST AND/OR PERMANENTLY EXPOSED TO EARTH B. 2 INCHES FROM FACE OF CONCRETE CAST IF IT IS EXPOSED TO EARTH AND/OR WEATHER. C. 1-1/2" INCHES FROM FACE OF CONCRETE CAST IF IT IS NOT EXPOSED TO WEATHER AND/OR IN CONTACT WITH EARTH. 1. PRE-MOISTEN EXCAVATIONS FOR FOOTING & SLAB PRIOR TO POURING CONCRETE. THE CONSULTING SOILS ENGINEER SHALL CHECK MOISTURE CONDITIONS. 2. ALL RECOMMENDATIONS OF THE CONSULTING GEOLOGIST MUST BE INCORPORATED INTO THE DESIGN OR SHOWN AS NOTES ON THE PLANS IF APPLICABLE. 3. IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE REQUIRED. (1802.2.1) 1. THE OWNER SHALL EMPLOY A STATE OF CALIFORNIA REGISTERED CIVIL OR STRUCTURAL ENGINEER OR LICENSED ARCHITECT TO PERFORM THE STRUCTURAL OBSERVATION. THE DEPARTMENT OF BUILDING AND SAFETY (LADBS) RECOMMENDS THE USE OF THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGNS THAT ARE INDEPENDENT OF THE CONTRACTOR. 2. THE STRUCTURAL OBSERVER SHALL PROVIDE EVIDENCE OF EMPLOYMENT BY THE OWNER OR THE OWNER'S REPRESENTATIVE. A LETTER FROM THE OWNER, THE OWNER'S REPRESENTATIVE OR A COPY OF THE AGREEMENT FOR SERVICES SHALL BE SENT TO THE BUILDING INSPECTOR BEFORE THE FIRST SITE VISIT. 3. THE OWNER OR OWNER'S REPRESENTATIVE SHALL COORDINATE AND CALL FOR A MEETING BETWEEN THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN, STRUCTURAL OBSERVER, CONTRACTOR, AFFECTED SUBCONTRACTORS AND DEPUTY INSPECTORS. THE PURPOSE OF THE MEETING SHALL BE TO IDENTIFY THE MAJOR STRUCTURAL ELEMENTS AND CONNECTIONS THAT AFFECT THE VERTICAL AND LATERAL LOAD SYSTEMS OF THE STRUCTURE AND TO REVIEW SCHEDULING OF THE REQUIRED OBSERVATIONS. A RECORD OF THE MEETING SHALL BE INCLUDED IN THE FIRST OBSERVATION REPORT SUBMITTED TO THE BUILDING INSPECTOR. 4. THE STRUCTURAL OBSERVER SHALL PERFORM SITE VISITS AT THOSE STEPS IN THE PROGRESS OF THE WORK THAT ALLOW FOR CORRECTION OF DEFICIENCIES WITHOUT SUBSTANTIAL EFFORT OR UNCOVERING OF THE WORK INVOLVED. AT A MINIMUM, THE LISTED SIGNIFICANT CONSTRUCTION STAGES ON THE FOLLOWING STRUCTURAL OBSERVATION AND/OR SIGNIFICANT CONSTRUCTION STAGES TABLE REQUIRE A SITE VISIT AND AN OBSERVATION REPORT FROM THE STRUCTURAL OBSERVER. 6. THE STRUCTURAL OBSERVER SHALL PREPARE A REPORT OF THE STRUCTURAL OBSERVATION REPORT FORM IN/FORM.08 (PART 1) FOR EACH SIGNIFICANT STAGE OF CONSTRUCTION OBSERVED. THE ORIGINAL OF THE STRUCTURAL OBSERVATION REPORT SHALL BE SENT TO THE BUILDING INSPECTOR'S OFFICE AND SHALL BE SIGNED AND SEALED (WET STAMP) BY THE RESPONSIBLE STRUCTURAL OBSERVER. ONE COPY OF THE OBSERVATION REPORT SHALL BE ATTACHED TO THE APPROVED PLANS. THE COPY ATTACHED TO THE PLANS SHALL BE SIGNED AND SEALED (WET STAMP) BY THE RESPONSIBLE STRUCTURAL OBSERVER OR THEIR DESIGNEE. COPIES OF THE REPORT SHALL ALSO BE GIVEN TO THE OWNER, CONTRACTOR, AND DEPUTY INSPECTOR. ANY DEFICIENCY NOTED ON THE OBSERVATION REPORT WILL BECOME THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER OF RECORD TO VERIFY ITS COMPLETION BY HIM (HER), OR BY A REGISTERED DEPUTY INSPECTOR AT THE DISCRETION OF THE STRUCTURAL OBSERVER. 7. A FINAL OBSERVATION REPORT AND THAT OF THE REGISTERED DEPUTY INSPECTOR MUST BE SUBMITTED WHICH SHOWS THAT ALL OBSERVED DEFICIENCIES WERE RESOLVED AND STRUCTURAL SYSTEM GENERALLY CONFORMS TO THE APPROVED PLANS AND SPECIFICATIONS. THE DEPARTMENT OF BUILDING AND SAFETY (LADBS) WILL NOT ACCEPT THE STRUCTURAL WORK WITHOUT THIS FINAL OBSERVATION REPORT AND THAT OF THE REGISTERED DEPUTY INSPECTOR (WHEN PROVIDED) AND THE CORRECTION OF SPECIFIC DEFICIENCIES NOTED DURING NORMAL BUILDING INSPECTION. 8. THE STRUCTURAL OBSERVER SHALL PROVIDE THE ORIGINAL STAMPED AND SIGNED STRUCTURAL OBSERVATION REPORT TO THE CITY'S DEPARTMENT OF BUILDING AND SAFETY INSPECTION OFFICE. 9. WHEN THE OWNER ELECTS TO CHANGE THE STRUCTURAL OBSERVER OF RECORD, THE OWNER SHALL: A. NOTIFY THE BUILDING INSPECTOR IN WRITING BEFORE THE NEXT INSPECTION BY SUBMITTING COMPLETED "STRUCTURAL OBSERVATION PROGRAM AND DESIGNATION OF THE STRUCTURAL OBSERVER" FORM IN/FORM.08 (PART 2) B. CALL AN ADDITIONAL PRE-CONSTRUCTION MEETING, AND C. FURNISH THE REPLACEMENT STRUCTURAL OBSERVER WITH A COPY OF ALL PREVIOUS OBSERVATION REPORTS. THE REPLACEMENT STRUCTURAL OBSERVER SHALL APPROVE THE CORRECTION OF THE ORIGINAL OBSERVED DEFICIENCIES UNLESS OTHERWISE APPROVED BY PLAN CHECK SUPERVISION. THE POLICY OF THE DEPARTMENT SHALL BE TO CORRECT ANY PROPERTY NOTED DEFICIENCIES WITHOUT CONSIDERATION OF THEIR SOURCE. 10.THE ENGINEER OR ARCHITECT OF RECORD SHALL DEVELOP ALL CHANGES RELATING TO THE STRUCTURAL SYSTEMS. THE BUILDING DEPARTMENT SHALL REVIEW AND APPROVE ALL CHANGES TO THE APPROVED PLANS AND SPECIFICATIONS. STRUCTURAL OBSERVATION CONSTRUCTION STAGE ELEMENTS TO BE OBSERVED CONCRETE LUMBER GROUT STEEL REINFORCEMENT EARTHWORK 1. CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, HIGH STRENGTH BOLTING AND SPRAYED-ON FIREPROOFING. 2. LADBS LICENSED FABRICATOR IS REQUIRED FOR STRUCTURAL STEEL. 3. ALL WELDING SHALL BE SHOP WELDED BY A CERTIFIED WELDING SHOP, UNLESS NOTED OTHERWISE. 4. SHOP WELDING FOR STRUCTURAL STEEL & LIGHT GAUGE STEEL SHALL BE PERFORMED IN A CERTIFIED FABRICATOR SHOP OR CALIFORNIA LICENSED FABRICATOR SHOP. 5. FIELD WELDING FOR STRUCTURAL STEEL & LIGHT GAUGE STEEL SHALL BE PERFORMED BY A CERTIFIED WELDERS OR CALIFORNIA LICENSED WELDER. CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING. STEEL CONSTRUCTION DEAD LOAD: HORIZONTAL SYSTEMS: ·ROOF CONSTRUCTION 15 PSF. ·CEILING CONSTRUCTION 10 PSF. ·FLOOR CONSTRUCTION 15 PSF. VERTICAL SYSTEMS: ·LIGHT-FRAME WALL CONSTRUCTION 20 PSF. ·MASONRY WALL CONSTRUCTION 120 PCF. ·CONCRETE WALL CONSTRUCTION 160 PCF. LIVE LOAD: ROOF SYSTEMS: ·SLOPE < 4:12 20 PSF. ·SLOPE =/> 4:12 16 PSF. ·ROOF SOLAR 5 PSF ATTIC SYSTEMS: ·W/O STORAGE SPACE 20 PSF. ·W/ STORAGE SPACE 30 PSF. FLOOR SYSTEMS: ·BEDROOM AREAS 30 PSF. ·OTHER AREAS 40 PSF WALLS: ·EXTERIOR WALLS 15 PSF. ·INTERIOR WALLS 10 PSF DESIGN LOAD DATA NO CONCRETE TOPPING ASSUMED IN DEAD LOAD CALCULATIONS. CONTRACTOR TO VERIFY IN FIELD GREEN NOTES 1. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES,, CONDUITS, OR OTHER OPENINGS IN THE BUILDINGS ENVELOPE AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY, OR METAL PLATES. 2. FOR ALL NEW EQUIPMENT, AN OPERATION AND MAINTENANCE MANUAL INCLUDING, AT A MINIMUM THE ITEMS LISTED IN SECTION 4.410.1, SHALL BE COMPLETED AND PLACED IN THE BUILDING AT THE TIME OF FINAL INSPECTION 3. ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL SARTUP OF THE HEATING, COOLING AND VENT. EQUIPMENT 4. THE VOC CONTENT VERIFICATION CHECKLIST SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURERS SPECIFICATIONS SHOWING VOC CONTENT FOR ALL APPLICABLE PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION 5. ALL NEW CARPET AND CARPET CUSHIONS INSTALLE DIN THE BUILDING INTERIOR SHALL MEET THE TESTING PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING 1. CARPET AND RUG INSTITUTES GREEN LABEL PLUS PROGRAM 2. CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 3. NSF/ANSI 140 AT THE GOLD LEVEL 4. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE 6. 80% OF THE TOTAL AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING 1. VOC EMISSION LIMITS DEFINED IN THE CHPS HIGH PERFORMANCE PRODUCTS DATABASE 2. CERTIFIED UNDER UL GREENGUARD GOLD 3. CERTIFICATION UNDER THE RESILIENT FLOOR COVERING INSTITUTE 4. MEET THE CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 7. THE HEATING AND AIR CONDITIONING SYSTEMS SHALL BE SIZED AND DESIGNED USING ANSI/ACCA MANUAL J-2004, ANSI/ACCA 29-D-2009 OR ASHRAE HANDBOOKS AND HAVE THEIR EQUIPMENT SELECTED IUN ACCORDANCE WITH ANSI/ACCA 36-S MANUAL S-2004 8. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80psi, OR THE SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN OPERATION AT A TIME 9. THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES IN SECTION 4.303.1 DESCRIPTION NAILINGSCHEDULE BLOCKING BETWEEN CEILING JOISTS OR RAFTERS TO TOP PL. # AND TYPE SPACING & LOCATION ROOF 4-8D BOX (21/2″ × 0.113″) OR TOE NAIL 3-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 3-3" × 0.131″ NAILS TOE NAIL CEILING JOIST TO TOP PL. 4-8D BOX (21/2″ × 0.113″); ORPER JOIST, 3-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 3-3″ × 0.131″ NAILS PER JOIST, TOE NAIL CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS 4-10D BOX (3″ × 0.128″); OR 3-16D COMMON (31/2″ × 0.162″); OR 4-3″ × 0.131″ NAILS FACE NAIL CEILING JOIST ATTACHED TO PARALLEL RAFTER (HEEL JOINT)TABLE 1, S-1 FACE NAIL COLLAR TIE TO RAFTER, FACE NAIL OR 11/4″ × 20 GA. RIDGE STRAP TO RAFTER 4-10D BOX (3″ × 0.128″); OR 3-10D COMMON (3″ × 0.148″); OR 4-3″ × 0.131″ NAILS FACE NAIL EACH RAFTER RAFTER OR ROOF TRUSS TO PLATE 3-16D BOX NAILS (31/2″ × 0.135″); OR 3-10D COMMON NAILS (3" × 0.148″); OR 4-10D BOX (3″ × 0.128″); OR 4-3″ × 0.131″ NAILS 2 TOE NAILS ON ONE SIDE AND 1 TOE NAIL ON OPPOSITE SIDE OF EACH RAFTER OR TRUSS ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS OR ROOF RAFTER TO MINIMUM 2″ RIDGE BEAM 4-16D (31/2″ × 0.135″); OR 3-10D COMMON (31/2″ × 0.148″); OR 4-10D BOX (3″ × 0.128″); OR 4-3″ × 0.131″ NAILS TOE NAIL 3-16D BOX 31/2″ × 0.135″); OR 2-16D COMMON (31/2″ × 0.162″); OR 3-10D BOX (3″ × 0.128″); OR 3-3″ × 0.131″ NAILS END NAIL WALL DESCRIPTION # AND TYPE SPACING & LOCATION STUD TO STUD (NOT AT BRACED WALL PANELS) 16D COMMON (31/2″ × 0.162″)24″ O.C. FACE NAIL 10D BOX (3″ × 0.128″); OR 3″ × 0.131″ NAILS 16″ O.C. FACE NAIL STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS (AT BRACED WALL PANELS) 16D BOX (31/2″ × 0.135″); OR 3" × 0.131" NAILS 12″ O.C. FACE NAIL 16D COMMON (31/2″ × 0.162″)16″ O.C. FACE NAIL BUILT-UP HEADER (2″ TO 2″ HEADER WITH 1/2″ SPACER) 16D COMMON (31/2″ × 0.162″)16″ O.C. EACH EDGE FACE NAIL 16D BOX (31/2″ × 0.135″)12″ O.C. EACH EDGE FACE NAIL CONTINUOUS HEADER TO STUD 5-8D BOX (21/2″ × 0.113″); OR4-8D COMMON (21/2″ × 0.131″); OR 4-10D BOX (3″ × 0.128″)TOE NAIL TOP PLATE TO TOP PLATE 16D COMMON (31/2″ × 0.162″)16″ O.C. FACE NAIL 10D BOX (3″ × 0.128″); OR 3″ × 0.131″ NAILS 12″ O.C. FACE NAIL DOUBLE TOP PLATE SPLICE FOR SDCS A-D2 WITH SEISMIC BRACED WALL LINE SPACING < 25' 8-16D COMMON (31/2″ × 0.162″); OR 12-16D BOX (31/2″ × 0.135″); OR 12-10D BOX (3″ × 0.128″); OR 12-3″ × 0.131″ NAILS FACE NAIL ON EACH SIDE OF END JOINT (MINIMUM 24″ LAP SPLICE LENGTH EACH SIDE OF END JOINT)DOUBLE TOP PLATE SPLICE SDCS D0, D1, OR D2; AND BRACED WALL LINE SPACING ≥25' 12-16D (31/2″ × 0.135″) BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) 16D COMMON (31/2″ × 0.162″)16″ O.C. FACE NAIL 16D BOX (31/2″ × 0.135″); OR 12″ O.C. 3″ × 0.131″ NAILS 12″ O.C. FACE NAIL BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (AT BRACED WALL PANEL) 3-16D BOX (31/2″ × 0.135″); OR 2-16D COMMON (31/2″ × 0.162″); OR4-3″ × 0.131″ NAILS 3 EACH 16″ O.C. FACE NAIL 2 EACH 16″ O.C. FACE NAIL 4 EACH 16″ O.C. FACE NAIL TOP OR BOTTOM PLATE TO STUD 4-8D BOX (21/2″ × 0.113″); OR3-16D BOX (31/2″ × 0.135″); OR 4-8D COMMON (21/2″ × 0.131″); OR 4-10D BOX (3″ × 0.128″); OR 4-3″ × 0.131″ NAILS TOE NAIL 3-16D BOX (31/2″ × 0.135″); OR 2-16D COMMON (31/2″ × 0.162″); OR 3-10D BOX (3″ × 0.128″); OR 3-3″ × 0.131″ NAILS END NAIL TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS 3-10D BOX (3″ × 0.128″); OR 2-16D COMMON (31/2″ × 0.162″); OR 3-3″ × 0.131″ NAILS FACE NAIL 1″ × 6″ SHEATHING TO EACH BEARING 3-8D BOX (21/2″ × 0.113″); OR 2-8D COMMON (21/2″ × 0.131″); OR 2-10D BOX (3″ × 0.128″); OR 2 STAPLES, 1″ CROWN, 16 GA., 13/4″ LONG FACE NAIL 1″ × 8″ AND WIDER SHEATHING TO EACH BEARING 3-8D BOX (21/2″ × 0.113″); OR3-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 3 STAPLES, 1″ CROWN, 16 GA., 13/4″ LONG FACE NAILWIDER THAN 1″ × 8″ 4-8D BOX (21/2″ × 0.113″); OR 3-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 4 STAPLES, 1″ CROWN, 16 GA., 13/4″ LONG JOIST TO SILL, TOP PLATE OR GIRDER 4-8D BOX (21/2″ × 0.113″); OR 3-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 3-3″ × 0.131″ NAILS TOE NAIL RIM JOIST, BAND JOIST OR BLOCKING TO SILL OR TOP PLATE (ROOF APPLICATIONS ALSO) 8D BOX (21/2″ × 0.113″)4" O.C. TOE NAIL 8D COMMON (21/2″ × 0.131″); OR 10D BOX (3″ × 0.128″); OR 3″ × 0.131″ NAILS)6″ O.C. TOE NAIL RIM JOIST, BAND JOIST OR BLOCKING TO SILL OR TOP PLATE (ROOF APPLICATIONS ALSO) 3-8D BOX (21/2″ × 0.113″); OR 2-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 2 STAPLES, 1″ CROWN, 16 GA., 13/4″ LONG FACE NAIL 2″ SUBFLOOR TO JOIST OR GIRDER 3-16D BOX (31/2″ × 0.135″); OR 2-16D COMMON (31/2″ × 0.162″)BLIND AND FACE NAIL 2″ PLANKS (PLANK & BEAM‒FLOOR & ROOF) 3-16D BOX (31/2″ × 0.135″); OR 2-16D COMMON (31/2″ × 0.162″)AT EACH BEARING, FACE NAIL WALL BAND OR RIM JOIST TO JOIST 3-16DCOMMON (31/2″ × 0.162″) 4-10 BOX (3″ × 0.128″), OR 4-3″ × 0.131″ NAILS; OR 4-3″ × 14 GA. STAPLES, 7/16″ CROWN END NAIL BUILT-UP GIRDERS AND BEAMS, 2-INCH LUMBER LAYERS 20D COMMON (4″ × 0.192″); OR NAIL EACH LAYER AS FOLLOWS: 32″ O.C. AT TOP AND BOTTOM AND STAGGERED. 10D BOX (3″ × 0.128″); OR 3″ × 0.131″ NAILS 24″ O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES AND: 2-20D COMMON (4″ × 0.192″); OR 3-10D BOX (3″ × 0.128″); OR 3-3″ × 0.131″ NAILS FACE NAIL AT ENDS AND AT EACH SPLICE LEDGER STRIP SUPPORTING JOISTS OR RAFTERS 4-16D BOX (31/2″ × 0.135″); OR 3-16D COMMON (31/2″ × 0.162″); OR 4-10D BOX (3″ × 0.128″); OR 4-3″ × 0.131″ NAILS AT EACH JOIST OR RAFTER, FACE NAIL BRIDGING TO JOIST 2-10D (3″ × 0.128″)EACH END, TOE NAIL RAFTER SLOPE 3:12 TABLE 1 4:12 5:12 7:12 9:12 12:12 RAFTER SPACING 121624 121624 121624 121624 121624121624 457345 334333 ROOF SPAN (ft) (inches)12 20 28 36 REQUIRED # OF 16d COMMON NAILS 333 333 6811568 457 445 344334 810156812 569 457 446 344 10131981015 6812569 567345 2017 GREENLEAF STREET GARAGE CONVERSION INTO ADU SHEAR WALL (E) GARAGE SLAB TO REMAIN (PROVIDE MIN. 3 COATS OF CONCRETE FLOOR MOISTURE RETARDANT BARRIER. USE REGARD WATERPROOFING MEMBRANE ESR-1413 OR EQUIV.) (N ) H D U 2 (N ) 4 " X 6 " 2 -- 1 -- 3 -- 4 -- 4 -- 4 -- 4 -- 4 -- 4 -- (N) H D U 2(N) 4" X 6 " (N) HD U 2 (N) 4"X 6 " (N) HDU 2 (N) 4"X6 " (N) H D U 2 (N) 4 " X 6 " (N) H D U 2 (N) 4 " X 6 " (N) HD U 2(N) 4"X 6 " 4 -- 2 SSW1 1 SSW1 2 SSW1 1 SSW1 (N) SIMPSON STRONG WALL FOOTING: F'c: 2,500 PSI 3/4"Ø STANDARD A.B. de: 8" MIN. 12 SD1 (N ) H D U 2 (N ) 4 " X 6 " 4 -- (N) HD U 2 (N) 4"X 6 "4 -- SFD (N) HD U 2 (N) 4"X 6 " (N) HDU2(N) 4"X6" L = 5'-5" 1 7 --(E ) 2 " X 1 0 " R . R . @ 1 6 " O . C . , T Y P . L = 1'-0" 2 L = 1'-0" 2 (N ) 4 " X 6 " (N ) H D U 2 (N ) 4 " X 6 " (N ) H D U 2 (N ) 4 " X 6 " (N) HD U 2 (N) 4"X 6 " (N) HDU 2 (N) 4"X6 " L = 6'-0" 1 (N) H D U 2 (N) 4 " X 6 " (N) H D U 2 (N) 4 " X 6 " L = 6'-0" 1 15 SD1 6 -- 6 -- L = 4'-0" 1 A B C 2 (N) H D U 2 (N) 4 " X 6 " (N ) H D U 2 (N ) 4 " X 6 " 6 -- L = 4'-0" 1 (N) 4"X8" HDR #1 2 SSW2 2 SSW2 (N) 4"X6" (N) 4"X8" (E ) H D R (N) HD U 2 (N) 4"X 6 " (N ) 4 " X 6 " (N) 2"X6" R.R. @ 16" O.C. 17 SD1 17 SD1 (N) 4" SLAB ON GRADE W/ #4 BARS @ 16" O.C. 1 -- 5 --14 SD1 16 SD1 (E ) 2 " X 1 0 " R . R . @ 1 6 " O . C . , T Y P . 2'-0" 2' - 6 " 2'-0" 2' - 6 " 18 SD1 TYP. 4 -- 4 --(N) H D U 2 (N) 4 " X 6 " (N) H D U 2 (N) 4 " X 6 " 18 SD1 TYP. (N) H D U 2 (N) 4 " X 6 " (N) H D U 2 (N) 4 " X 6 " L = 4'-0" 1 6 -- (E) FOOTING WIDTH: 12" MIN.V.I.F. (E) FOOTING DEPTH: 24" MIN. V.I.F. 4 3 1 2 DOWEL DETAIL (N) FTG.(E) FTG. P.T. MUDSILL W/ ANCHOR BOLTS PER PLAN S.S.T. "LSTA36" @ (N) AND (E) SILL PL. CONNECTION (WHERE OCCURS) REBAR PER PLANS, TYP. 24"8" #4 DOWELS, T&B EPOXY SET WITH SIMPSON SET-XP EPOXY (RR25744), SPECIAL DEPUTY INSP. REQ'D. (E) SLAB 12" MIN. 24 " MI N . #5 DOWELS @ 16" O.C., W/ 6" MIN EMB. EPOXY SET WITH SIMPSON SET-3G EPOXY (ESR-4057), SPECIAL DEPUTY INSP. REQ'D. (N) CONC. FTG PER PLANS NOTE: SEE SCHEARWALL SCHEDULE FOR A.B. SPACING IN SHEARWALL P.T. MUDSILL W/ (N) 1/2"Ø ANCHOR BOLTS AND 3"x3"x5/16" WASHERS @ 6'-0" O.C. W/ 7" MIN. EMB. STUD WALL PER PLANS SHEAR PANEL'G. PER SCHEDULE (WHERE OCCURS) INTERIOR SLAB FOOTING 2- #4 HORIZ. BARS @ T&B., TYP. (E) SLAB 134" MIN. POST PER PLANS 58"Ø SIMPSON "SSTB16" 12 58" M I N . 14 116 " MA X . 178" HOLD DOWN @ NEW SLAB 134" MIN. POST PER PLANS 10 " MI N . HOLD DOWN @ EXISTING SLAB SIMPSON HOLD DOWN PER PLANS SIMPSON HOLD DOWN PER PLANS #5 DOWELS @ 16" O.C., W/ 6" MIN EMB. EPOXY SET WITH SIMPSON SET-3G EPOXY (ESR-4057), SPECIAL DEPUTY INSP. REQ'D. TYPICAL HEADER FRAMING HEADER SEE SCHEDULE HEADER SCHEDULE MIN. HEADER SIZEMAX OPENING WIDTH BEARING WALL NON-BRG. WALL 4'-0" 6'-0" 8'-0" 10'-0" 12'-0" 4 X 14 4 X 12 4 X 10 4 X 6 4 X 4 4 X 6 4 X 8 4 X 10 4 X 12 4 X 8 SEE ARCHITECTURAL PLANS TOP PLATE A35 UNDER HEADER 4 X 8 OR SMALLER 'EPC' UNDER 4 X 10 OR 4 X 12 'ECC" LARGER U.N.O. DBL. STUD UNDER HEADER 4 X 8 OR SMALLER 4 X POST UNDER 4 X 10 OR LARGER U.N.O. SIMPSON "A35" WHEN OPEN'G WIDTH EXCEEDS 5'-0" ("A35'S" @2 X 6 STUDS) 2 - 16d (3 - 16d @ HDRS. DEEPER THAN 4") USE 2 - 2 X KING STUDS AT OPENINGS WIDER THAN 6' - 0" 2 X BLK'G 16d @ 12" O.C. STAGGERED TYP. DBL. FULL HT.STUDS WHEN OPENING WIDTH EXCEEDS 5' - 0" SIMPSON "A35" WHEN OPEN'G WIDTH EXCEEDS 5' - 0" ("A35'S" @ 2 X 6 STUDS) 75SHEAR TRANSFER DETAIL SHEARWALL PER SCHED. 2-2X TOP PL. E.N. STUD WALL PER PLANS SIMPSON "A35" @ EA. BAY. (SEE SHEARWALL SCHEDULE FIR SPACING @ SHEARWALL LOCATIONS) RAFTERS PER PLANS SHEARWALL PER SCHED. 2-2X TOP PL. E.N. STUD WALL PER PLANS SIMPSON "A35" @ EA. BAY. (SEE SHEARWALL SCHEDULE FIR SPACING @ SHEARWALL LOCATIONS) RAFTERS PER PLANS (E) ROOF SHEATHING TO REMAIN, TYP. 1 - 14" x 6" LAG SCREW (E) ROOF SHEATHING TO REMAIN, TYP. SHEAR TRANSFER DETAIL6 8 JOIST PER PLAN "A35" EA. BAY (SEE SHEARWALL SCHEDULE FOR SPACING IN SHEARWALL LOCATIONS 2-2X TOP PL. RAFTERS PER PLAN STUD WALL PER PLANS E.N. SHEATHING PER SCHEDULE FRAMING DETAIL (E) ROOF SHEATHING TO REMAIN, TYP. SHEAR TRANSFER DETAIL 2X BLOCKING TO BE SAME DEPTH AS JOIST OR RAFTER SPACED @ 4'-0" MAX. BETWEEN SUPPORTS. (SEE DETAIL #3/ SHEET SD1) 2X BLOCKING TO BE SAME DEPTH AS JOIST OR RAFTER SPACED @ 4'-0" MAX. BETWEEN SUPPORTS. (SEE DETAIL #3/ SHEET SD1) DR A W I N G D A T E : A u g 1 8 , 2 0 2 5 ( 1 : 2 9 P M ) SHEET #: JO B A D D R E S S : 20 1 7 G R E E N L E A F S T . SA N T A A N A , C A 9 2 7 0 6 NO . RE V I S I O N : DA T E : B Y : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N AT T A C H E D G A R A G E CO N V E R S I O N I N T O AD U SSDSTA N D L E Y S T R U C T U R A L D E S I G N CIVI L - S T R U C T U R A L E N G I N E E R S Located at: 18757 BURBANK BLVD. UNIT 109 TARZANA, CA 91356 Call: (213) 373-4513 A. G . A. G . FO U N D A T I O N P L A N / RO O F F R A M I N G P L A N S-2FOUNDATION PLAN (PROPOSED) SHOWING AREA OF WORK SCALE: 3/8"=1'-0" HOLD DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS;AND HOLD DOWNS SHALL BE FINGER TIGHT AND WRENCH TURNED JUST PRIOR TO COVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD FRAMINMG REQUIRE STEEL PLATE WASHERS ON THE POST ON THE OPPOSITE SIDE OF THE ANCHORAGE DEVICE. PLATE SIZE SHALL BE A MINIMUM OF 0.299 INCH BY 3 INCHES BY 3 INCHES ROOF FRAMING PLAN (PROPOSED) SHOWING AREA OF WORK SCALE: 3/8"=1'-0" PLYWOOD SHEAR ANC. SHEARWALL SCHEDULE EDGE NAILINGTAG CAPACITY NOTES: 1) NAILING IS IN ADDITION TO THE MINIMUM REQUIREMENTS OF C.B.C. - TABLE 2304.9.1 2) HDU2 HOLD DOWN AT EACH END 3) SOLID BLOCK AND NAIL ALL PLYWOOD EDGES 4) PROVIDE 12" EDGE DISTANCE FOR PLYWOOD BOUNDARY NAILING 1 FIELD NAILING ANC. BOLT 15/32" STRUCT. 1 LTP4 @ 16" O.C.10d COM. @ 6" O.C. 2 340 plf10d COM. @ 12" O.C.58" @ 32" O.C.* PER MFR.N/A 3 7755 lbsN/A PER MFR.SSW 12X8 ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX ALL BOLT HOLES SHALL BE DRILLED 132" TO 116" OVERSIZED HOLD DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION NOTCHES WITHIN 13SPAN EA. END 1 BOUNDARY NAILING (B.N.) 2 EDGE NAILING (E.N.) 3 INTERMEDIATE NAILING: 10" O.C. @ FLOORS 12" O.C. @ ROOF, SAME SIZE AS EDGE NAILING 4 3X4 FLAT BLOCKING (U.N.O.) 5 SEE PLANS FOR PLYWOOD THICKNESS AND NAILING 6 2'-0" X 4'-0" MIN. SIZE OF PLYWOOD SHEET. 7 LONG DIMENSION (FACE GRAIN) PLYWOOD SHALL RUN ACROSS JOISTS OR RAFTERS 8 NAILS SHALL HAVE A MIN, 38" EDGE DISTANCE AND SHALL NOT BE OVERDRIVEN THROUGH PLYWOOD 9 CONTINUOUS PANEL EDGES SHALL RECEIVE BOUNDARY NAILING 1 34 2 "D " D 14 M A X @ E N D S D 16 M A X . D 13 M A X . (2 " M I N . ) 2" M A X . D 13 M A X . (2 " M I N . ) 2" M A X . NOTCHES NOT PERMITTED WITHIN MIDDLE THIRD OF SPAN, BUT BORED HOLES ARE PERMITTED BORED HOLES ALSO PERMITTED ELEVATION PROVIDE STUDS BELOW SPLICES 2 - 2X4 TOP PLATES 12 - 16d EA. SIDE OF SPLICE OR SIMSON ST22 ONE SIDE ONLY 16d @ 16" O.C. SPLICE @ UPPER PLATE 4' - 0"MIN. SPLICE @ LOWER PLATE 2 X 3 CROSS BRIDGING @ 4' - 0" O.C. MAX. BETWEEN SUPPORTS NOTE: STEEL CROSS BRIDING MAY BE USED @ SAME SPACING NAIL W/2 - 16d EA. END OF 2 X 3 NAIL @ BOTTOM OF JOIST OR RAFTER TO BE DRIVEN AFTER SHEATHING 15 PLACES & NAIL DOWN CROSS BLOCKING IN LIEU OF WOOD BLOCKING SIMPSON TB20 BRIDGING STRAP MAY BE USDED SOLID BLOCKING NOTE: 2 x BLOCKING TO BE SAME DEPTH AS JOIST OR RAFTER SPACED @ 4'-0" MAX. BETWEEN SUPPORTS. 2 - 16d @ END NAILS EACH BLOCK AS SHOWN 5/8"MIN *40% MAX. STUD WIDTH NOTCH 25% MAX. STUD WIDTH NOTCH 60% MAX. STUD WIDTH BORE 40% MAX. STUD WIDTH BORE 5/8"MIN * NON-BEARING STUDS BEARING STUDSNOTE: 1. NOTCH AND BORING NOT TO OCCUR IN SAME STUD SECTION. 2. NO MORE THAN 2 SUCCESSIVE DOUBLE STUDS MAY HAVE 60% BORED HOLES.* PORTION OF STUD REMAINING AT NOTCHES OR HOLES SHALL BE SOUND WOOD WITHOUT EXCESSIVE STRENGTH REDUCING PROPERTIES SUCH AS KNOTS, BREAKS, SPLITS, EXCESSIVE SLOPE GRAIN, ETC. NOTCH / BORE % OF STUD 2 X 4 2 X 6 7/8" 1 3/8" 2 1/8" 25% 40% 60% 1 3/8" 2 3/16" 3 5/16" DBL. STUDS (BRG. OR NON-BRG.) 60 % M A X . ST U D W I D T H 1 1/2"1 1/2" 1 NOTCHING AND BORING OF FLOOR JOISTS 2 NON-BEARING PARTITION WALL TOP CONN.3 TYPICAL BLOCKING DETAIL 4 5ROOF AND FLOOR DIAPHRAGM 6 NOTCHING AND BORING OF STUDS 7 TOP PLATE SPLICE DETAIL 8 9 2-10d TOE NAILS EA. JOIST EA. SIDE 2-10d FACE NAILS 2X FLAT BLKG' FINISH PER PLANS JOISTS PER PLANS JOIST 2X STUDS @ 16" O.C. 2X STUDS @ 16" O.C. INTERSECTION WOOD FRAMING WALL INTERSECTION CORNER DBL. JOIST JOIST DBL. JOIST SIMPSON "U" HANGER OPEN AREA TYP. FLR. AND ROOF OPENING 11 12 10 14 15 NEW FRAMINGEXISTING FRAMING NEW FRAMINGEXISTING FRAMING FIT SNUG SIMPSON LSTA36 @ BOTH SIDES OF PLATES NOTE: UPON CONSTRUCTING THE NEW EXTERIOR WALLS PROVIDE LSTA36 STRAPS AT BOTH SIDE OF TOP & BOT. PLATES OF THE STUD WALL TO CREATE THE CONTINUITY OF THE STUD WALL WITH THE REST OF THE EXISTING WALL. LINTEL SIZE SCHEDULE SPANH UP TO 6'-0"5 1/2" 6'-0" TO 8'-0"7 1/4" 8'-0" TO 10'-0"9 1/4" LINTEL SIZES GIVEN ARE MINIMUMS LARGER SIZES SHALL BE USED WHERE CALLED FOR BY PLANS OR BY SPECIFIC DETAILS MATCH STUD WIDTH H SE E SC H E D U L E SOLID BUILT-UP BLOCK @ 24" O.C. MAXIMUM WITH 2-16d NAILS FROM EACH SIDE A34 TOP AND BOTTOM OF JAMB AT OPENINGS MORE THAN 3'-0" IN EXTERIOR WALLS ONLY 2 X BLOCKING AT MIDHEIGHT OR 8'0" MAX. 2 X SILL PLATE W/ " A.B. PER PLANS HOLD DOWN AS OCCURS MIN 3/4" DRYPACK AS LEVELING BASE UNLESS BASE IS LEVEL WITHIN 1/8" IN 10'-0" NOTE: WALL FRAMING OVER FRAMED FLOOR SIMILAR 5' MIN. 9' MAX.DOUBLE STUD JAMB AT OPENINGS MORE THAN 4'-0" JACK STUD AT LINTEL USE DOUBLE JACK STUD AT OPENINGS MORE THAN 6'-0" U.N.O. A35 CLIP AT OPENINGS MORE THAN 3'-0" AT EXT. WALLS ONLY SOLID OR BUILT-UP LINTEL OVER OPENING DOUBLE TOP PLATE FOR SPLICE SEE DET. 5 3-16d MIN TYPICAL WALL FRAMING DETAIL 17 TYPICAL FRAMING DETAIL 16 DBL. JOIST ADDITIONAL JOIST BELOW WALL PER PLANS 4" MAX FOR PLUMBING NO PARRALLEL PLYWD.JOINTS BTWN. JOISTS ALTERNATE "A" 34" MIN. BRG. ALTERNATE "B"ALTERNATE "C" WALL LENGTHS GREATER THAN 3'-0" IN LENGTH NON-BEARING WALL 12THE LENGTH OR LESS OF JOIST SPAN DBL. 2X4 @ 24" O.C. LAP W/ (2) 10d 2-16d END NAILS EA. END 1-1/2" MIN. ALIGN JOIST BELOW WALL JOIST PER PLAN ALTERNATE "B" WALL LENGTHS LESS THAN THAN 3'-0" IN LENGTH ALTERNATE "A" TYP. NON-BEARING PARTITION WALL BTTM. CONN. 18 19 20 (E) SLAB 12" MIN. 24 " MI N . 1- #4 HORIZ. BAR #5 DOWELS @ 16" O.C., W/ 6" MIN EMB. EPOXY SET WITH SIMPSON SET-3G EPOXY (ESR-4057), SPECIAL DEPUTY INSP. REQ'D. (N) CONC. FTG PER PLANS NOTE: SEE SCHEARWALL SCHEDULE FOR A.B. SPACING IN SHEARWALL P.T. MUDSILL W/ (N) 1/2"Ø ANCHOR BOLTS AND 3"x3"x5/16" WASHERS @ 6'-0" O.C. W/ 7" MIN. EMB. STUD WALL PER PLANS SHEAR PANEL'G. PER SCHEDULE (WHERE OCCURS) 8" MI N . EXTERIOR FINISH PER PLANS EXTERIOR SLAB FOOTING (1-STORY) 2- #4 HORIZ. BARS @ T&B., TYP. 6" MIN. B.N. E.N. 2X SOLID BLKG' UPLIFT FRAMING CLIP "A35" FRAMING ANCHOR AT EACH BAY 2-2X TOP PL. STUD WALL PER PLANS (N) PLYWOOD SHEAR WALL PER PLAN (WHERE OCCURS) EAVE FRAMING DETAIL PER PLAN RAFTER PER PLANS (N) SEALANT (N) R.R. PER PLANS (N) SIMPSON "HU" JOIST HANGER OR EQUIVALENT. (L.A.R.R. #25807) 26 GALV. FLASHING STRIP (N) 2X LEDGER W/ 12" X 5 " LAG BOLT EA. STUD (E) STUD WALL 12" COX. PLY. SHEATHING (MIN.) SLOPE (14"/FT.) (N) 2X BLKG' @ 4'-0" O.C. FRAMING DETAIL (N) 1532" WOOD STRUCTURAL PANEL W/ 8d @ 6"/6"/12" (N) PLYWOOD SHEAR WALL PER PLAN (WHERE OCCURS) E.N. STUD WALL PER PLANS RAFTERS PER PLANS (N) 2X BLOCKING (N) BARGE RAFTER (N) 2X BLOCKING VERGE RAFTER FRAMING @ GABLE ENDS (N) 1532" WOOD STRUCTURAL PANEL W/ 8d @ 6"/6"/12" A35 FRAMING ANCHOR PER SHEARWALL SCHED. 24" LAP TYP. TOP BARS 4" SLAB PER PLAN, TYP. 12" MIN. 24 " M I N . P.T. MUDSILL W/ (N) 1/2"Ø ANCHOR BOLTS AND 3"x3"x5/16" WASHERS @ 4'-0" O.C. W/ 7" MIN. EMB. SHEAR PANEL'G. PER SCHEDULE (WHERE OCCURS) 8" MI N . G.I. WEEP SCREED EXTERIOR FINISH PER PLANS NOTE: SEE SCHEARWALL SCHEDULE FOR A.B. SPACING IN SHEARWALL #4 BAR @ 16" O.C.E.W, TYP. 10 MIL VISQUEEN, (PLASTIC VAPOR BARRIER) STUD WALL PER PLANS EXTERIOR SLAB FOOTING 4" THICK BASE OF 12" CLEAN AGGREGATE2 - #4 BARS T&B #4 CONT. BAR , TYP. 6" MIN. 134" MIN. SHEAR WALL PER PLAN 58"Ø ANCHOR BOLTS @ 32" O.C. U.N.O. SET WITH SIMPSON SET-3G EPOXY (ESR-4057) OR EQUIV., SPECIAL DEPUTY INSP. REQ'D. 10 " MI N . ANCHOR BOLTS @ EXISTING SLAB DR A W I N G D A T E : A u g 1 8 , 2 0 2 5 ( 1 : 2 9 P M ) SHEET #: JO B A D D R E S S : 20 1 7 G R E E N L E A F S T . SA N T A A N A , C A 9 2 7 0 6 NO . RE V I S I O N : DA T E : B Y : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N AT T A C H E D G A R A G E CO N V E R S I O N I N T O AD U SSDSTA N D L E Y S T R U C T U R A L D E S I G N CIVI L - S T R U C T U R A L E N G I N E E R S Located at: 18757 BURBANK BLVD. UNIT 109 TARZANA, CA 91356 Call: (213) 373-4513 A. G . A. G . ST R U C T U R A L D E T A I L S SD1 CITY OF SANTA ANA THAN %", SEE DET. 5 - ATTACH TOP OF WALL TO TOP PLATES WITH SDS �"x3Y2" SCREWS (PROVIDED) --- STEEL PANEL FRAMING BY - OTHERS RAKE WALL OTHERS CRIPPLE WALL DESIGNER SHALL DESIGN FOR; 1. SHEAR TRANSFER 2. OUT of PLANE LOADING EFFECT 3. INCREASED OVERTURNING AND DRIFT DUE TO ADDITIONAL HEIGHT / AT 2'-0' O.C. MAXIMUM. WHERE FRAMING �S y4"x" SCREWS IS PARALLEL TO WALL, INSTALL BLOCKING INCLUDED WITH WALL l WITHIN I" OF EACH END IDF STEEL ( ) STRONG -WALL. BLOCKING DEPTH SHALL FIRST STORY 'DEL STRONG -WALL MATCH FLOOR FRAMING DEPTH. ALLOWABLE LOADS. - 3• FOR TWO-STORY STACKED STEEL STRONG -WALLS WITH WOOD FIRST 7 FLOOR, USE ALTERNATE DETAIL. _ 4. DESIGNER SHALL DESIGN FOR SHEAR TRANSFER FROM RIM JOIST TO SILL PLATE AND SILL PLATE TO FOUNDATION.. '$ +- DESIGNER IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. TOP OF WALL HEIGHT ADJUSTMENTS 5 TWO-STORY STAC KED FLOOR SECTION 8 FIRST FLOOR AT WOOD FRAMING 10 oPT�oNAL PILOT HOLE PREFABRICATED HOLES IN STEEL PANEL, (VARY WITH EACH MODEL) ADDITIONAL CUTTING OF STEEL WALL OR ENLARGING PLACE SSW PANEL OVER THREADED DRILL 2' DIAMETER x 1' DEEP RODS AND SECURE WITH HEAVY HEX HOLE OR NOTCH 20x2"x1' DEEP NUTS (PROVIDED). USE 1%w HEADER BY OTHERS. 2 PLY 2x12 MIN WITH Y2" 16d COMMON NAILING. SLL SHEATHING BETWEEN PLYS -., SIDE VIEWS FOR SPACING. OF EXISTING HOLES NOT PERMITTED. f� ELECTRICAL BUSHINGS AT ALL ? OR ALTQI�4TE 00- ROUND MECHANICAL HOLES. 4 7 ALTERNATE DESIGNER IS PERMITTED TO MODIFY - H DETAILS FOR SPECIFIC CONDITIONS. r SINGLE -STORY SSW ON C ONC RETE 2 9 GARAGE HEADER 2 OR 5 SHEAR TRANSFER DESIGN ALTERNATE ROUGH OPENING HEIGHT ----------------- &DETAILS BY OTHERS ----- ROUGH_ MODEL NO. H CURB OPENING HEIGHT SSW12X7 ,. 7,-1}�" SSW15X7 SS*W18X7 SSWf21X7 5" 7'-2" SSW24X SSMII2X7 SSW15X7 512" 8'_2Yj4,. SSM118X7 SSW121 X7 6• �_ SSW24X7 W W II II '0 0 SM4 0 SS- 24 0 0 0' 53W2 Q 0 El SSW21 LJ H 0 0 SSWiB '•.0 0 0 0 SSW15 VA 0 0. SSW12 WALL PROFILES TABLE NOTES 1. SDS 1A'x3%m SCREWS PROVIDED WITH WALL. ?. SEE SHEET SM FOR ANCHORAGE SOLUTIONS. MODEL SSW--IIKT. EXAMPLE; SSW21-lKT SHEAR TRANSFER PLATE (PROVIDED STEEL STRONG -WALL WITH SSW_-1KT) RIM JOIST �� BLOCKING BELOW SSW SCREWS TO SHIM BLOCK STEEL STRONG -WALL DETAILS FOR SPECIFIC CONDITIONS. - JOIST HANGER TO SHIM BLOCK � a . • ` . • ` ° . „ ; (IF REQUIRED) ° ` INSTEAD OF SDS Y"x3Y2" 0 ° ° SHEAR TRANSFER PLATE Qa SCREWS PROVIDED. 0 0 0 0 �� ADJACENT � 0 0 0 AND #14 SELF --DRILLING �� FRAMING -� SCREWS (PROVIDED NTH FLOOR SHEATHING � FLAT SHIM BLOCK BY OTHERS SSW'- 2KT). 0 2X L 4X SHIM BLOCK ° 4: FLOOR FRAMING AT 2'-0" C CRIPPLE SHEAR a SOLID BLOCKING BELOW' °° ° • `A SHEAR °° OC MAX. WHERE FRAMING °D o �? 4x SHAPED SHIM WALL, BLOCKING - 10d COMMONS .' • `• ' ° it d TRANSFER BY °ate. 1S PARALLEL TO WALL, . o "v BLOCK (12" MAX. ANDS BY STEEL STRONG WALL ° 'rn DEPTH AT TALL BETWEEN FLOOR FRAMING TO FRAMING 'w • OTHERS (LTP4 ` INSTALL BLOCKING WITHIN N �' OTHERS 10d COMMON NAILS (NOT PROVIDED) +! �� SHOWN) 8' OF EACH END Of SSW, z a° a J, STEEL STRONG -WALL MODELS END) (NOT PROVIDED) BLOCKING DEPTH SHALL N a MATCH FLOOR FRAMING. J ; LTP4 SPACING ATTACH SDS EXTERIOR ELEVATION SEC TION w o BY OTHERS � � oo , RIM JOIST, BERM, OR - TOP PLATE SCREWS TO RIM JOIST FIRST FLOOR AT WOOD FRAMING NOTES BLOCKING IF APPLICABLE ATTACH SDS BLOCKING 7/g' MAXIMUM WOOD SHIM c 1. USE WOOD FIRST -FLOOR ALLOWABLE LOAD TABLES FROM THE - � a �- WITH SDS Ya"x3Y2" SCREWS. ° ° ° ° _ SCREWS gip ° ° ° SHEAR TRANSFER BY STRONG -WALL CATALOG FOR THIS INSTALLATION. � • " ' FOR SHIMS GREATER 0 0 0 0 FTIP1.1. 0 ADJACENT OTHERS {SIMPSON LTP4 § _ .. 1.1. .. , ADJACENT . FRAMING BY SHOWN FOR ILLUSTRATION 2. USE ALTERNATE DETAIL TO ACHIEVE MAXIMUM ON -CONCRETE Y' HOLES TO ATTACH ) PERPENDICULAR FLOOR FRAMING SPACED OPTIONAL BLOCKING OR FRAMING PRE -ATTACHED WOOD STUDS ADDITIONAL 1X" DIAMETER HOLES MAY BE DRILLED THRU WOOD STUDS AT ANY HOLE LOCATION MATCHING AN OBROUND HOLE IN STEEL PANEL FLANGE. HOLES PREDRILLED IN STUDS FOR WIRING. ADDITIONAL 1' HOLE MAY BE DRILLED THROUGH WOOD STUD AT 1' HOLE WITH �-- GROMMET LOCATIONS. STEEL STRONG -WALL MODELS SM. WALL MODEL NO. -STK WALL MODEL NO. H(in) Ton) HOLDOWN ANCHOR BOLTS" 57.7 TOP OF WALL SCREWS SSW12x7 -- 80 3Y2 2-Y" 4 SSW15x7 -- 80 3Y2 2-1' 6 SSW18x7 -- 80 3Y2 2-1' 9 SSW21x7 -- 80 3,V 2-1" 12 SSW24x7 -- 80 3Y 2-1" 14 SSW12x7.4 -- 85,Y2 3Y 2-Y4" 4 SSW15x7.4 -- 85Y2 3Y2 2-1 " 6 SSW18x7.4 - - 85Y2 3Y 2-1 " 9 SSW21x7.4 -- 85,Y2 3Y2 2-1" 12 SSW24x7.4 -- 85Y 3Y2 2-1" 1 14 SSW12x8 -- 93)/4 3Y 2-Ya 4 SSW15x8 SSW15X8-STK 93Ya 3Y2 2-1" 6 SSW18x8 SSW18x8-STK 93Ya 3Y 2-1" 9 _SSW21 x8 SSW21 x8-STK 93Ya _3Y2 2-1" 12 SS"W24x8 . SSW24x®_-STK 93Y4 _3� 2-1" 14 SSW1bg -- 105Y4 3Y2 -A 4 SSW15x9 SSW15x9-STK 105Y4 3Y2 2-1 _ 6 SSW18x9 SSW18x9-STK 105Ya 3Y2 2-1 9 SSW21x9_ SSW21x9-STKLl 5Ya 3Y ir 2-1 12 SSW24x9 SSW24x9-STK5Y4 __3Y2 2-1 14 SSW12x10 -- 7Y _3Y2-3�4.. 4 SSW15x10 SSW15x1O-STK7Y 3Y 2-1" 6 SSW18x10 SSW18x14-STK 117Y4 3Y2 2-1" 9 SSW21x10 SSW21x10-STK 117Y4 3Y 2-1" 12 SSW24x10 SSW24x10-STK 117Y4 3Y2 2-1" 14 SSW15x11 SSW15x11•-STK 129Y4 5Y2 2-1w- SSW18x11 SSW18x11-STK 129Y4 5Y 2-10 9 SSW21x11 SSW21x11-STK 129y4 5Y2 2-10 12 SSW24x11 SSWI24x11-STK 129)'4 5Y 2-10 14 SSW15x12 SSW1502-STK 141Y4 5Y2 2-1" 6 SSW18x12 SSW18x12-STK 141Y4 5Y 2-10 9 SSW21x12 SSW21 x12-STK 141Ya I 5Y2 2-1" 12 SSW2402 SSW24x12-STK 141Ya 5Y2 2-1 14 SSW18x13 SSW18x13-STK 153Y4 5Y 2-1" 9 SSW21 x13 SSW21 x13-STK 153Y 5Y2 2-1" 12 SSW24x13 SSW24xl3-STK 153Y4 5Y2 2-1 14 lil ,II •I PLACE SSW PANEL OVER THE ANCHOR DRILL 2' DIAMETER x 1PLACE SSW PANEL OVER ROFkI a n d B i i g e ( I O O o o BOLTS AND SECURE WITH HEAVY HEX STEEL DEEP HOLE OR NOTCH WITH HEAVY HEX THREADED NUTS (10 ). cn ,n cn v, NUTS (PROVIDED). STRONG -WALL r x1 DEEP MAX. IN USE 1Y4" WRENCH/ SOCKET FOR %" NUT 0 0 0 c_ USE 1Y" WRENCH/ SOCKET FOR. -" NUT SHEATHING dt RIMI JOIST. 0 0 0 0 USE 1%" WRENCH/ SOC ET FOR 1" NUT > "-' > > USE 15/8' WRENCH/ SOCKET FOR 1" NUT NAILING SET LOWER NUT FLUSH NUTS SHALL BE SNUG TI HT. z � � w D5 . .. BY OTHERS WITH TOP OF SHEATHING. o NUTS SHALL BE SNAG TIGHT. FRAMING BY JOIST HANGER SSW BASE PLATE SHALL DO NOT USE AN IMPACT WRENCIri. � " m m an .130 DO NOT USE AN IMPACT WRENCH. OTHERS TYPICAL Ap N N - No (IF REQUIRED) SIT FLUSH & LEVEL ON SIMPSON A34 EACH SID p N N _ .. 1 4 0 0 0 oo NUTS. SOLID BLOCKING ELO It: O R PERMIT a NC . ° SEE SSW1 TO SSW1 FOR STEEL STRONG- ALL. o 0 000 CO �- ., ANCHORAGE SOLUTIONS M WOOD FIRST -FLOG WALL CONNECTION KIT � o C> , Y c3 0 o p c DESIGNER IS PERMITTED TO MODIFY WALL DETAILS FOR SPECIFIC CONDITIONS. ' �, ° '� I Q :: WIDTH MODEL NO. CONTENTS Q :. *•' ° L •e G d '•�, .4 + ' '•a c 12 Mastpr ID:_ SSW12-1KT KIT }CONT.AI�1S; STRONG -WALL O N CONCRETE - COUPLER NUT s • ... ObamNSFFR r LATE 4 SEC TION AND THREADED • .` i a 15 SSW15-1KT • • •, . � ( ith #14 SCREWS) - RODS (INCLUDED ' • a ()"x18" or 1 "xi 8" THREAD DESIGNER IS PERMITTED TO Mt1D1FY FOR 12' IXOCK PLACE SSW PANEL OVER THE ANCHOR 1 4 WITH SSW_-1KT) ` . ' � `� 18 SSW18-1KT SIMPSON CSi6 STRAPS REQI11iED BOLTS MID SECURE WITH HEAVY HEX SEE TO FOR DETAILS FOR SPECIFIC CONDITIONS. " 5SW1 SW1 J WITH 1 NAILS 0.148 x1. NUTS PROMMOM 2) COUPLER NUTS { 5') ( �. 21 SSW21-11CT ( I SHIM HEIGHTS GREATER USE 1W IlII NCHI SOCKET FOR �" NUT ANCHORAGE SOLUTIONS SEE SHEET SSW1 (2) HEAVY HEX NUTS FOR ANCHORAGE INTERIOR ELEVATION 24 �SSW24-10 INSTALLATION INSTRUGTlONSTHAN 8" AID UP TO 10":E_. USE 1 WRENCH/ SOCKET FOR 1 NUT DESIGNER IS PERMITTED TO MODIFY SOLUTIONS. L I ..... 8 NAILS INTO BLOCK NUTS SHALL BE SNUG TIGHT. 8 INTO SSW NAILER STUD DO NOT USE AN IMPACT DETAILS FOR SPECIFIC CONDITIONS. ORDER FIRST FLOOR CONNECTOR KIT SEPARATELY SHIM BLOCK HEIGHTS GREATER 14 SCREWS TO 2x FLAT SHIM BLOCK THAN 10 AND UP TO 12: # 10 NAILS INTO BLOCK FLOOR 0 R WOOD D FRAMING /� n ,� G 7 PANEL (PROVIDED LTP4 SPACING f 10INTO SSWfJAIIER STUD ALTERNATE 1ST AMIN WITH SSW--1KT) BY OTHERS 4x SHIM BLOCK ATTACH WITH SOS Y"x4Y2" • • • 2"d STORY DESIGNER IS PERMITTED TO MODIFY ATTACH SDS SCREWS PLATES WITH SDS Y4"x3V LUMBER HEADER PLYS. 4 SCREWS TOTAL IY- - SCREWS (PROVIDED WITH SSW) FOR SSW12, 6 SCREWS TOTAL FOR SSWI5, __j LL L9 SSW18, SSW21 AND SSW24. L Z HEAVY HEX NUT'S TOP AND D__ 2. SDS 4"x3Y" SCREWS PROVIDED WITH WALL � W BOTTOM (PROVIDED WITH lY2 3• FASTEN PLYS TOGETHER WITH 16d COMMON NAILS " SSMt -2KT). NUTS SHALL BE o 0 o I o BEAM. AT 16 O.C. ALONG EACH EDGE OF F SNUG TIGHT. DO NOT USE AN - - REQUIREMENTS = ROD LENGTH IS TOTAL OF IMPACT WRENCH'. 4 15/32" SHEATHING BETWEEN 2x HEADER 11 - FLOOR JOIST DEPTH PLUS TOP INTERIOR ELEVATION PLYS SHALL MATCH HEADER DEPTH AND EXTEND FULL WIDTH OF SSW, MINIMUM. SEE - O.O.O.O � PLATES PLUS SHIM THICKNESS. 1 2 I s • s J ORDER TWO-STORY SHEAR TRANSFER PLATE AND #14 SELF -DRILLING STEEL STRONG -WALL 0 0 • STACKED WALL CONNECTOR SCREWS (PROVIDED WITH SSW= 2KT) 0 0 0 0 (SSW18 SHOWN) � z ° SEE SHEET S_s W4 KIT SEPARATELY. MODEL SIDE VIEW z 0 0 FOR GARAGE ___ __- _ _ SSW= 2KT, EX; SSW21-2KT SHEAR TRANSFER BY OTHERS - Ll PORTAL SYSTEM RIM JOIST SSW WITH MULTI -PLY HEADER uj uj I. THE HEIGHT OF THE GARAGE CURB WHEN S S WP - K T (LTP4 SHOWN) I ROUGH A L\ ABOVE THE GARAGE SLAB IS CR TIC& IS SPECIFIEDis FOR THE ROUGH HEADER OPENING AT OPENING HEIGHT FIRST STORY' WALL: DESIGNER IS PERMITTED TID MODIFY MULTI -PLY HEADERS 11 y� •'•"•'• GARAGE RETURN WALLS. O . 0 ADD-STK TO MODEL O O O O DETAILS FOR SPECIFIC CONDITIONS. • 1. STEEL STRONG -WALL SHEARWALL IS MANUFACTURED AND TRADEMARKED 6Y "SIMPSON STRONG -TIE COMPANY, 2. SHIMS ARE NOT PROVIDED WITH STEEL POST & POST NAME. STRONG -MALL " 4 EX: SSW21x9-STK - INC. HOME OFFICE: 5956 W. LAS POSITAS BLVD., PLEASANTON, CA 94588 TEL: (800) 999-5099, FAX: 3. FURRING ON UNDERSIDE OF GARAGE BASE DETAIL 0 0 0 O (925) 847-1597. "SIMPSON STRONG -TIE COMPANY, INC." IS AN ISO 9001 REGISTERED COMPANY. AYE HEADER MAY BE NECESSARY FOR - _ BY OTHERS - TWO-STORY STACKED 2. USE OF THIS PRODUCT IS SUBJECT TO THE APPROVAL OF THE LOCAL BUILDING DEPARTMENT. DATE LESSER ROUGH OPENING HEIGHTS. ! WALL CONNECTION KIT 3. THIS PRODUCT IS PART OF THE OVERALL LATERAL FORCE RESISTING SYSTEM OF THE STRUCTURE DESIGN OF 03-1�1 DESIGNER IS PERMITTED TO MODIFY a H . CURB a ° 0 , DETAILS FOR SPECIFIC CONDITIONS. d ` 4 ' - GARAGE WALL OPTION 1 GARAGE WALL OPTION 2 FOR GARAGE WALL OPTION 2 4. NO DESIGNER SHALL DESIGN FOR: -"- - DESIGNER IS PERMITTED TO 7-FT. HIGH STEEL. STRONG -WALL MODELS 1. SHEAR TRANSFER e 7 �' OR ALTERNATE a :' •• o MODIFY DETAILS FOR SPECIFIC ARE 8W, r TALLER THAN 7-FT. HIGH 2. OUT OF PLANE LOADING EFFECT _ CONDITIONS. WOOD STRONG -WALL SHEARWA�LS 3. INCREASED OVERTURNING AND DRIFT DUE TO ADDITIONAL HEIGHT MAX. IN SHEATHING & RIM 0 0 0 0 WRENCH/ SOCKET FOR 1' NUT OR 2 PLY 94'x11 %" MIN. -j JOIST. SET LOWER NUT FLUSH NUTS SHALL BE SNUG TIGHT. DO LVL (2 PLY LVL SHOWN) INSTALL SDS Y4"x3Y7" SCREWS. SEE WITH TOP OF SHEATHING. SSW NOT USE AN IMPACT WRENCH. SIDE VIEWS FOR NUMBER & SPACING EASE PLATE SHALL SIT FLUSH & LEVEL ON NUTS. SIMPSON A34 EACH SIDE NIQ� : (SCREWS BY INSTALLER) MULTI -PLY HEADERS MAY I ccBE Z USED WITH STEEL 1Y2" DESIGNER IS PERMITTED TO MODIFY 0 10 DIAMETER .. SOLID BLOCKING BELOW STRONG -WALL FOR WIND DETAILS FOR SPECIFIC CONDITIONS. J STANDARD STEEL STEEL STRONG -WALL DESIGNS OR IN SEISMIC cc STRONG -WALL THREADED RODS DESIGN CATEGORIES A-C � W AT 2"d FLOOR (PROVIDED WITH (IBC & IRC) ONLY SDS Y4"x3Y2" SCREWS Lu 0 SSW -am PROVIDED WITH WALL 0 93 13 FOR SHIMS GREATER 8 DRILL lY,s" MAX DIAMETER hIQLE _ SSW Z 00 Of IN DOUBLE TOP PLATE FOR RODS SSW MULTI PLY HEADER CROSS SECTION - Lu THAN � SEE 6 1' MIN. 1. INSTALL SDS Y"x3Y2" SCREWS �� W O O ATTACH TOP OF SSW TO TOP 2„ TYP 2„ 3 HORIZONTALLY THROUGH LVL OR 2x v J Q Z HEADER BY OTHERS. • I FOR MULTI -PLY SSW-STK OPTION ' -HEADER (FACTORY INSTALLED) % . 38" MIN WIDTH 0000 0 0 0 0 ° 0000 0• 0 0 • e MAXIMUM ROD UPPER PANEL LENGTH SHEAR REDUC 71ON FACTOR IS INCHES 1.00 21INCHES 0.94 WALL WIDTH MODEL N0. CONTENTS (In) 15 1 SSW15-2KT EACH 10T CONTAINS: (1) SHEAR TRANSFER PLATE 18 SSW18-2KT (01% #14 SCREWS) (2)1'x48" TREADED RODS 21 SSW21-2KT (ASTM A36) (6) HEAVY HEX NUTS INSTALLATION INSTRUCTIONS 24 SSW24-2KT 10d COMMON U �y O NAILS (NOT U INCLUDED) THE BUILDINGS LATERAL FORCE RESISTING SYSTEM, INCLUDING THE LOAD PATH TO TRANSFER LATERAL FORCES FROM THE STRUCTURE TO THE GROUND, IS THE RESPONSIBILITY OF THE SPECIFIER. 4. ENGINEER OF RECORD IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. SlCALE N.T.S. CMEWCKED 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ELEVATIONS, ETC. PRIOR TO INSTALLATION OF ' ANY COMPONENTS FOR THE STEEL STRONG -WALL SYSTEM. IF ANY DISCREPANCIES ARE FOUND, THEY SHALL SHEET BE BROUGHT TO THE ATTENTION OF THE SPECIFIER FOR CLARIFICATION PRIOR TO CONSTRUCTION. 6. INSTALLATION OF PRODUCT SHALL BE DONE IN CONFORMANCE TO THESE DRAWINGS. THE PERFORMANCE OF ` MODIFIED PRODUCTS OR ALTERED INSTALLATION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE SSW2 SPECIFIER. 7. SIMPSON STRONG -TIE COMPANY, INC. RESERVES THE RIGHT TO CHANCE SPEcinCATIONS, DESIGNS, AND EXTERIOR ELEVATION MODELS WITHOUT NOTICE OR LIABILITY FOR SUCH CHANGES. 8. ALL HARDWARE CALLED OUT IS SIMPSON STRONG -TIE. OF SHEETS LALTERNATE GARAGE WALL OPTIONS 3 TWO-STORY STACKED 161 TWO-STORY STACKED FLOOR FRAMING 9 NOTES 12 JOB NO. CITY OF SANTA ANA SSWAB SSWAB SHEAR REINFORCEMENT PER MINIMUM CURB/STEMWALL 3" 4/SSW1 WHEN REQUIRED. '3� WIDTH PER 4/SSWI. SHEAR REINFORCEMENT PER �. 4/SSW1 WHEN REQUIRED. ,•• �• d d a de A de e ° Lid° •• J �. 4: ° °f .4 A� •., 37 CLR. MIN. 16. .0 , ,3" CLR. MIN. - • `� " • . 11 - iu YW Yw Yaw W W -qI AR nN GRAnF FnUNnATInm CURB OR STEMWALL FOUNDATION STEEL STRONG -WALL ANCHORAGE SOLUTIONS FOR 3500 PSI CONCRETE DESIGN CRITERIA CONCRETE CONDITION ANCHOR STRENGTH STANDARD SSWAS 3/4" ANCHOR BOLT SSWAB 1' ANCHOR BOLT ASD ALLOWABLE UPLIFT (Ibs) W (in) d6 on) AM ALLIDWABLE UPUFT (Ibs) w (in) do (in) SEISMIC CRACKED 9,0 0 20 0 9,600 21 7 17,1001 HIGH STRENGTH 18,200 32 11 00 1 19,900 34 12 35,300 1 UNCRACKED STANDARD 8,800 17 6 15,700 25 9 9,600 19 7 17,100 27 1 9 HIGH SWNGTH 18,600 28 10 3Z600 40 1 14 19,900 30 10 35.300 4 14 WIND CRACKED STANDARD 6,000 14 6 7.300 16 6 7 300 6 5o0 24 9,600 7 17,100 29 HIGH STRta1GTH 11,800 8 22,700 34 13,500 8 10 27•400 32,300 38 42 T ,000 19,900 11 35,300 45 15 UNCRACKED STANDARD 6,000 6 7,500 14 6 7,500 14 6 12,800 20 7 91600 17 6 17,100 25 9 HIGH STRENGTH 17800 20 7 21,300 28 10 14,80G 22 8 26,000 32 11 0 8 1 31,300 36 12 19,9uu 1 27 9 1 35,300 39 13 STEEL STRONG -WALL ANCHORAGE SOLUTIONS FOR 4500 PSI CCNcFRffmng DESIGN CRITERIA CONCRETE CONDITION ANCHOR STRENGTH SSWAB 3/4" ANCHOR BOLT SSWAB 1" BOLT ASD ALLOWABLE UPLIFT (Ibs) � O in ( ) ALLOWABLE UPLIFT (Ibs) in t } 8� SEISMIC CRACKED STANDARD 8,700 1a 8 16,000023 9,600 20 7 ,100 HIGH STRENGTH 17,80 29 10 ,100 4 15 19,90 32 11 35,300 UNCRACKED STANDARD 9,100 1 6 15,7008 9 9,600 17 6 17,100 HIGH STRENGTH 17,800 1 25 1 9 32,500 37 13 19,90 ' 27 1 9 35,300 39 13 WIND CRACKED STANDARD 5,400 12 1 6 6,800 14 8,300 6 11,600 9,600 6 17,100 26 9 HIGH STRENGTH 11600 20 7 21,400 10 13,400 22 8 25,800 12 17,300 26 9 31,000 38 13 19,900 29 10 35,300 42 14 UNCRACKED STANDARD 6,800 12 6 6, Do 12 v 8,500 14 6 12,400 18 9,600 16 6 17,100 23 HIGH STRENGTH 12, 0 18 6 2 0 26 14,500 20 7 0 30 10 16,800 1 22 1 8 1 34 19.900 1 25 1 9 1 36 1 12 no nuicong Ageny o g rn cn � N > arc � pr mI C o rs Ito ;CINN I I - - NOTES 1. ANCHORAGE DESIGNS CONFORM TO ACI 318-19, ACI 318-14 AND ACI 318-11 APPENDIX D WITH NO SUPPLEMENTARY REINFORCEMENT FOR CRACKED OR UNCRACKED CONCRETE AS NOTED. DESIGNER IS PERMITTED TO MODIFY 2. ANCHOR STRENGTH INDICATES REQUIRED GRADE OF SSWAB ANCHOR BOLT. STANDARD (ASTM F1554 GRADE 36) OR HIGH STRENGTH (HS) (ASTM A449). DETAILS FOR SPECIFIC CONDITIONS. SSWAB 3. SEISMIC INDICATES SOSMIC DESIGN CATEGORY C THROUGH F. DETACHED 1 AND 2 FAMILY DWEWNGS IN SDC C MAY USE WIND ANCHORAGE SOLUTIONS. SEISMIC ANCHORAGE DESIGNS CONFORM TD ACI 318-�19 SECTION 17.10.5.3, ACI 318--14 SECTION 17.2.3i.4.3 U AND ACI 318-11 SECTION D.3.3.4. C MINIMUM CURB/STEMWALL4. WIND INCLUDES SEISMIC DESIGN CATEGORY A AND B AND DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC a WIDTH PER 4/SSWT. 5. FOUNDATION DIMENSIONS ARE FOR ANCHORAGE ONLY. FOUNDATION DESIGN (SIZE AND REINFORCEMENT) BY OTHERS. THE DESIGNER MAY SPECIFY ALTERNATE EMBEDMENT, FOOTING SIZE OR ANCHOR BOLT. U 3„ SSWAB SHEAR REINFORCEMENT PER S. SEE 1/5SMVt AND 2/5SW1 FOR W AND de. 4/SSW1 WHEN REQUIRED. . •f..., SSWAB TENSION ANCHORAGE SCHEDULE 3500/4500 PSI 3 H e 4 +• ° a ya r :S Ea MIN ,d• ••�. •+ ..t....•, :.c 4"MIN 0�� CTI� A •. d t•�. A4 - -- -_ 4 ' • ' AIe ,. .� . 3 3 �• - __ - - 3" CLR. MIN4 _- -- MITI _ #3 HAIRPIN, GRADE 60 #3 HAIRPIN, GRADE 60 3 CLR_. MIN. REBAR (MIN.) REBAR (MIN.) YEW W YW W FIELD TIE AND SECURE DURING SSWAB CONCRETE PLACEMENT. OVERLAP FIELD TIE AND SECURE DURING SSWAB W W VARIES WITH BOLT SPACING. � PLACOYIENT' HAIRPIN SHEAR REINFORCEMENT TIE SHEAR REINFORCEMENT INTERIOR FOUNDATION BRICK LEDGE FOUNDATION #3 HAIRPIN (#3 TIE SIMILAR). C SEE TABLE FOR REQUIRED QUANTITY. NOTES 1. SEE 2/SSWI AND 3/SSW1 FOR DIMENSIONS AND ADDITIONAL NOTES. SSWAB A SS'VAI1 SEE#3 TIRPI REQUIRED QUANTITY. STEEL STRONG -WALL SHEAR ANCHORAGE SEISMIC' WIND4 MODEL 4 OR Lh (h) SHEAR REINFORCEMENT MIN_ CURE/ STEMWALL WIDTH (in.) SHEAR REINFORCEMENT MIN. CURB / STEMWALL WIDTH (in.) AM ALLOWABLE SHEAR LOAD V (Ibs.)6 r MIN CURH/S7EMWALL 8" MIN CURB / STEMWALL UNCRACKED CRACKED UNCRACKED CRACKED SSW12 9 (1) #3 TIE 6 NONE REQUIRED - 1230 880 1440 1030 SSW15 12 (2) 03 TIES 6 NONE REQUIRED - 1590 1135 1 1810 1295 SSW18 14 (1) #3 HAIRPIN 85 (1) #3 HAIRPIN 6 HAIRPINOWABLE ELOAD OF TFET STEP„ STRONG -WA ACHIM MAXIMUM AP NEL SSW21 15 (2) #3 HAIRPIN 85 (1) #3 HAIRPIN 6 SSW24 17 (2) 03 HAIRPIN 85 (1) #3 HAIRPIN 6 O w <m 3 0cl) � � 3 J O O � � a1 N a� ��a►°'3 J Q 0 ". u„ . o z of - w 2. SEE 4/5SW1 FOR SHEAR REINFORCEMENT WHEN REQUIRED. _ 3. MAXIMUM H - le - de. SEE 5,/SSW1 AND 6/SSWT FOR le. IV SPACING Y2" CLR " CLR NOTES • +: �• a�° =' •y� 1. SHEAR ANCHORAGE DESIGNS CONFORM TO ACI 318-19, ACI 318--14 AND ACI 318-11 AND ASSUME MINIMUM STEEL STRONG -WALL ANCHORAGE - TYPICAL SECTIONS 1 : ° ° ° • •• ��2,5oU PSI CONCRETE. SEE DETAILS 1/SW1 TO 3/SSWI FOR TENSION ANCHORAGE. ° ` •° •° ' ` ' + DESIGNER IS PERMITTED TO MODIFY 2. SHEAR REINFORCEMENT IS NOT REQUIRED FOR PANELS INSTALLED ON A WOOD FLOOR, INTERIOR FOUNDATION ` DETAILS FOR SPECIFIC CONDITIONS. '• d ••� •° •• • °'' 4 APPLICATIONS (PANEL INSTALLED AWAY FROM EDGE OF CONCIt -n OR BRACED WALL PANEL APPLICATIONS. SIMPSON STEEL SLAB OR CURB AND SURROUNDING ♦ �•� ' •• + ' ° 3. SEISMIC INDICATES SEISMIC DESIGN CATEGORY C THROUGH F. DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C STRON"ALL FOUNDATION NOT SHOWN FOR CLARITY a v 4Q�..1.a •� o ' '�. ° ' MAY USE WIND ANCHORAGE SOLUTIONS. 4. WIND INCLUDES SEISMIC DESIGN CATEGORY A AND B. SSWAB 5. MINIMUM CURB/STEMWALL WIDTH IS C WHEN STANDARD STRENGTH SSWAB IS USED. 8. USE (1) #3 TIE FOR SSW12 AND SSW15 WHEN THE STEEL. STRONG -WALL PANEL DESIGN SHEAR FORCE EXCEEDS < Y2w-;7:-- aa.• ` • • !. d•• r • • CO COHAIRPIN INSTALLATION SECTION A THE TABULATED ANCHORAGE ALLOWABLE !SHEAR LOAD. • �� (GARAGE CURB SHOWN. OTHER 7. CONCRETE EDGE DISTANCE FOR ANCHORS MUST COMPLY WITH ACI 318-19 SECTION 17.9.Z ACI 318-14 SECTION � J Z W . 4 , FOOTING TYPES SIMILAR. 17.7.2 AND ACI 318-11 0.8.2. 1 < ° `` co yzW 'f �' :. •� T STRONG -WALL ANC HOR B OLT SHEAR ANCHORAGE 4 w S EEL W B �2W DIAMETER SSWHSR_KT SSWHSR AND SSWT EXTERIOR SSWTPF PANEL o 0 a SEE TABLES BELOW FOR DIMENSIONS LENGTH SSWAB ASSEMBLY INSTALLATION FORM INSTALLATION 0,00 Q 0L FOUNDATION PLAN VIEW # W. LL.I 1 36 ? 24 TOP OF CONCRETE O W „ STEEL STRONG -WALL ANC HORAGE SOLUTIONS FOR 2500 PSI C O N C BETE DESIGN CR17EFJA CONCRETE CONDITION ANCHOR STRENGTH SSWAB ;Y4s ANCHOR OLT SSWAB 1" ANCHOR BOLT ASD ALLABLE UPLIFT (Ibs) n (in) ( ) ASD ALLOWABLE UPLIFT (Ibs) n O) de On) SEISMIC CRACKED STANDARD 8,800 22 1 8 16,100 9,600 24 8 17,100 HIGH STRENGTH 18,500 36 12 33,000 19,900 38 13 35,300 54 18 UNCRACKED STANDARD 8,800 19 7 15,700 28 1 1 9,600 21 7 17,100 1 1 HIGH STRENGTH 18,300 31 11 32,300 441 15 19,900 33 11 35,300 47 16 WIND CRACKED STANDARD 5,100 14 6 1 6,200 6 -48 6 7,400 18 E 11,400 91600 22 8 17100 32 11 HIGH STRENGTH 11.400 24 8 00 36 12 13,600 27 9 2T.300 42 14 15,900 30 10 3T1800 46 16 19,900 35 12 0 50 17 UNCRACKED STANDARD 5,000 12 6 6.400 14 6 7,800 16 6 12,500 22 8 9,600 19 7 17,100 2.8 10 HIGH STRENGTH 12,500 22 5 1 21,900 32 11 14,300 24 8 26,400 36 12 17,000 27 9 31,500 1 40 14 19,900 10 35,300 1 4 2X4 PREATTACHED Hs _ 3 = Z STUD FOR MODELS UP TO 10 FEET TALL 3 - HS ON HIGH 3 HX ON ° '� 0 B STRENGTH MODELS = EXTENSION KIT TOP R 1 1 Q Z CONCRETE 1 _ L..LI W ° (2 jr SSWAB for SSW12 3Y2" x 0 0 C TOP OF CONCRETE SSWHSR (2) 1' SSWAB for SSW15, If 11 HEAVY HEX NUT FIXED aS11Y18, SSW21, SSW24 ^ LENGTH IN PLACE ON ALL QT] �2) ?4 SSWAB for SSW12SSWAB ANCHOR BOLTS CUT TO LENGTH - _ 21" SSWAB for SSM,%, LDrG•IH HEAVY HEX NUT FIXED AS NECESSARY 2X8 PREATTACHED IN PLACE ON ALL I 3" SSW18, SSW21, SSW24 STUD FOR MODELS I SSWAB ANCHOR BOLTS TALLER THAN 10 FEET Y4- OR 1" HIGH STRENGTH ROD ASSEMBLY Ie = �I I STEEL STRONG -WALL ANCHOR BOLT LAYOUT HEAVY HEX NUT SSWAB le p STRENGTH • - + SSWHSR 1e+3Of DISTANCE FROM DISTANCE FROM DISTANCE FROM EXTERIOR FACE WALL END OF WALL TO C ENTER TO OF WALL TO MODEL CENTER OF CENTER OF CENTER OF ALL SSWA138 (A) On.) SSWAB (B) (in.) SSWA13s (C) (M.) SSW12 2% 6 % 2 SSw15 2% 9Y4 1 SSWAB 2% 12Y4 1% SSW 2 % 15Ya 136 SSW24 23/ 18y 13/ NOTES : 1. ANCHORAGE DESIGNS CONFORM TO ACI 318-19, ACI 318-14 AND ACI 318-11 APPENDIX D WITH NO SUPPLEMENTARY REINFORCEMENT FOR CRACKED OR UNCRACKED CONCRETE AS NOTED. 2. ANCHOR STRENGTH INDICATES REQUIRED GRADE OF SSWAB ANCHOR BOLT. STANDARD (ASTM F1554 GRADE 36) OR HIGH STRENGTH (HS) (ASTM A449). 3. SEISMIC INDICATES SEISMIC DESIGN CATEGORY C THROUGH F. DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C MAY USE WIND ANCHORAGE SOLUTIONS. SEISMIC ANCHORAGE DESIGNS CONFORM TO ACI 318-19 SECTION 17.10.5.3, ACI 318-14 SECTION 17.2.14.3 AND ACI 318-11 SECTION D.3.3.4. 4. WIND INCLUDES SEISMIC DESIGN CATEGORY A AND B AND DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C. & FOUNDATION DIMENSIONS ARE FOR ANCHORAGE ONLY. FOUNDATION DESIGN (SIZE AND REINFORCEMENT) BY OTHERS. THE DESIGNER MAY SPECIFY ALTERNATE EMBEDMENT, FOOTING SIZE OR ANCHOR BOLT. 8. REFER TO f /SSWT FOR Co. - � PLATE WASHER COUPLO2 NUT � SSWAB SSWT INTERIOR INSTALLATION 0 0 HEAVY HEX NUT o HIGH STRENGTH SSWT B IC K STEEL STRONG- WALL WIDTH MODEL NO. DIAMETER LENGTH I,. 12" MODEL SSWAB3/4x24 _" 24" 19' SSWAB3/4x24HS 3/" 24" 19" SSWAB3/,4xxn3O %a" 30" 25" SSWAB3/4xXHS 3i4,. 30" 25" SSWAB3/4x38HS 36" 310' 5", 18", 21" AND 24" MODELS SSWA81 x24 1s 24" 19" SSWAB1x24HS 1" 24" 19" SSWAB1x30 1" 30" 25" SSWAB1x30HS 1a 30" 25" SSWAB1x38HS 1' 360' 31a COUPIIx NUT L R LEDGE INSTALLATION NAME (2) �Y SSWAB for SSW12 DATE (2) 1" SSWAB for SSW15, 03-16-2021 o SCALE SSW & SSW21, SSW24 (2) * SSWAB for SSW12 N.T.S. 2 1" SSWAB for SSW15, CHECKED SSW18 SSW21 SSW24 SSW WIDTH MODEL NO. DIAMETER TOTAL LENGTH 6 SSWHSR3/4-2KT Y4" 24" 21" 12" MODEL SSWHSR3/4-3KT Y4" 36" 33" 1'5", 18", 21" SSWHSRI-2KT 1" 24" 21" AND 24" MODELS SSWHSRI-3A(T 1" 36" 33' 2x2 , SHEET • •°♦ SSW1 A j+ OF SHEETS SOB Na. SSWAB TENSION ANCHORAGE SCHEDULE 2500 PSI 2 SSW ANCHOR BOLTS 5 SSW ANCHOR BOLT EXTENSION 1 6 SSW ANCHOR BOLT TEMPLATES � DR A W I N G D A T E : Au g 1 8 , 2 0 2 5 ( 1 : 2 8 P M ) SHEET #: JO B A D D R E S S : 20 1 7 G R E E N L E A F S T . SA N T A A N A , C A 9 2 7 0 6 NO . RE V I S I O N : DA T E : B Y : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N AT T A C H E D G A R A G E CO N V E R S I O N I N T O AD U SSDSTA N D L E Y S T R U C T U R A L D E S I G N CIVI L - S T R U C T U R A L E N G I N E E R S Located at: 18757 BURBANK BLVD. UNIT 109 TARZANA, CA 91356 Call: (213) 373-4513 A. G . A. G . TI T L E - 2 4 F O R M S A-5 DR A W I N G D A T E : Au g 1 8 , 2 0 2 5 ( 1 : 2 8 P M ) SHEET #: JO B A D D R E S S : 20 1 7 G R E E N L E A F S T . SA N T A A N A , C A 9 2 7 0 6 NO . RE V I S I O N : DA T E : B Y : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N AT T A C H E D G A R A G E CO N V E R S I O N I N T O AD U SSDSTA N D L E Y S T R U C T U R A L D E S I G N CIVI L - S T R U C T U R A L E N G I N E E R S Located at: 18757 BURBANK BLVD. UNIT 109 TARZANA, CA 91356 Call: (213) 373-4513 A. G . A. G . RE S I D E N T I A L M A N D A T O R Y ME A S U R E S A-6 APP-13 CBC 2016 NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvem ents specified at ___________________________________________________________________________________________. We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your names as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owne r, obtain the prior approval of the permitting authority. OWNER’S ACKNOWLEGMENT AND VERIFICATION OF INFORMATON DIRECTIONS: Read and initial each statement below to signify you understand or verify this information. _____1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an “Owner -Builder” build- ing permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner’s insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my prop- erty. _____2. I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. _____3. I understand as an “Owner-Builder” I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead o f my own. _____4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbe rs on permits and contracts. _____5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an “employer” under state and federal law. _____6. I understand if I am considered an “employer” under state and Federal law, I must register with the state and federa l government, withhold payroll taxes, provide workers’ compensation disability insurance, and contribute to unemployment com- pensation of each “employee.” I also understand my failure to abide by these laws may subject me to serious financial risk. _____7. I understand under California Contractors’ State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontrac- tors and the number of structures does not exceed four within any calendar years, or all of the work is performed under contr act with a licensed general building Contractor. _____8. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any f inan- cial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workma n- ship or materials. Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org _____9. I understand I may obtain more information regarding my obligations as an “employer” from the Internal Revenue Ser- vice, the United States Small Business Administration, the California Department of Benefit Payments, and the California Divi- sion of Industrial Accidents. I also understand I may contact the California Contractors’ State License Board (CSLB) at 1 -800- 321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. _____10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the following ad- dress:_________________________________________________________________________________________. _____11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner -Builders as well as employers. ____12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the informati on I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors’ State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to underst and that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contactors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers’ compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner’s driver’s license, form notariza- tion, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner’s signature. Signature of Property Owner _____________________________________________ Date: ______________________ Print name of Owner __________________________________________________ AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER’S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work):_______________________________________________________ Project Location or Address: ____________________________________________________________________________ Name of Authorized Agent: _____________________________________________________________________________ Address of Authorized Agent:__________________________________________________________________________ Phone Number of Authorized Agent: ______________________________________________________________________ I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Property Owner’s Signature: __________________________________________________ Date:______________________ Print Name of Owner: ______________________________________________________________ Note: A copy of the owner’s driver’s license, form notarization, or other verification acceptable to the agency is re- quired to be presented when the permit is issued to verify the property owner’s signature. O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 18757 Burbank Blvd. Unit 109 Tarzana, CA 91356 213.373.4513 standleystructural.com Structural Calculations for Garage Conversion into Adu at: 2017 Greenleaf St. Santa Ana, CA 92706 Table of Contents: 1: Applicable Codes, General Design Parameters 2: U.S.G.S. Report 3: Design Parameters 4: Summary Of Loading 5: Equivalent Lateral Force Procedure 6: Shear Wall Design Applicable Codes: 2022 California Building Code, 2022 California Electrical Code, 2022 California Mechanical Code, American Society of Civil Engineers Standard ASCE-7-16 Minimum Design Loads for Buildings and other Structures, 2018 American Forest & Paper Association National Design Specification for Wood Construction, Local Municipal Code, and all other codes which are adapted by reference or enacted by law. Design Parameters: Assumed Design Parameters: All concrete foundations are f’c=2,500 psi or stronger Soil Values: No soils report, minimum soils values Timber Members: Douglas Fir #2 or better assumed Seismic Analysis Procedure: Equivalent Lateral Force Procedure Lateral Force Resisting System: Light framed wood shear wall, sheathed with structural wood panels Summary of Loading: Roof Live Load: 20 PSF Roof Dead Load: 15 PSF Ceiling Live Load: 20 PSF Ceiling Dead Load: 10 PSF Exterior Walls: 15 PSF Interior Walls: 10 PSF Equivalent Lateral Force Procedure: Ie = 1.0 R = 6.5 (Light Framed Timber Shear Wall) Cs = SDS/(R/Ie) Cs = 0.879 / (6.5/1) = 0.135 Seismic Forces – ADU (worst case – Line B shear wall): Roof D.L.: 15PSF x 284 SF = 4,260 lbs Ceiling D.L.: 10PSF x 0 SF = 0 lbs (N/A - flat roof) Exterior Walls: .5 x 8’ x 97’ x 15PSF = 5,820 lbs Interior Walls: .5 x 8’ x 13’ x 10PSF = 520 lbs Total DL: W= 10,600 lbs V= CsWρ = .135 x 10,600 lbs x 1.3 = 1,861 lbs Shear Wall Design (Worst Case): Shear Wall Length: 5’-6” Required Shear Wall Capacity: .7(1,861 lbs) / 5.5’ = 237 PLF SDPWS Nominal Shear Wall Values 15/32” Struc I Ply, Nailed W/10d Nails @ 6” O.C. Nominal Capacity: 950 PLF Per SDPWS 4.1.4 divide by 2.8 per ASD Design Capacity 950 PLF /2.8 = 340 PLF 340 PLF > 237 PLF OK Use 15/32” Struc I Ply, Nailed W/10d Nails @ 6” O.C. For Addition Walls Check Hold Downs HDU2: Max Tension 3,075 LBS Allowable Max Tension: 0.75 x 3,075 LBS = 2,306 LBS Max Tension: .7(1,861 LBS) x 8’ / 5.5’ = 1,895 LBS 1,895 LBS < 2,306 LBS OK USE HDU2 Hold Downs at each end of Shear Wall Check Shear Wall to Floor Connection LTP4 Capacity: 580 LBS, A35 Capacity: 595 LBS .7(1,861 LBS) / 580 LBS = 2.2 LTP4’s necessary Use minimum 3 LTP4’s 66” / 3 = 22” Use LTP4 or A35’s Every 16” Along Addition Shear Wall Simpson Steel Strong Wall Design (Line A): V = (113SF / 284 SF) x 1,861 lbs = 741 lbs .7(741 lbs) = 519 lbs / 2 = 260 lbs 775 lbs > 260 lbs OK – Use two SSW12X8 Simpson Steel Strong Wall Check Overturning about point o: V x h = HD x w 260 lbs x 8’ = HD x 0.573’ HD Required: 3,631 lbs 8,800 lbs > 3,631 lbs OK USE STANDARD SSWAB 3/4” ANCHOR BOLT CONCRETE CONDITION CRACKED WITH A WIDTH OF 22” AND de OF 8” & f’c:2,500psi Check Overturning: OTM: VxH = 260 lbs x 8’ = 2,080 ft-lbs Soil Bearing Strength Per 1806.2: 1,500 PSF Seismic Soils Bearing Strength: (4/3) x 1,500 PSF = 2,000 PSF 2,000 PSF X 2’ X 2.5’/2 = 5,000 lbs Bearing Resistance, Resisting Moment: 5,000 lbs x 2/3(2.5’) = 8,333 ft-lbs 8,333 ft-lbs > 2,080 ft-lbs OK Resistance to Sliding: V= 260 lbs Per Table 1806.2 Cohesion = 130 psf Resistance from footing: Surface Area of bottom of footing = (2x2.5) = 5 SF Resistance to sliding = 5 SF x 130 psf = 650 lbs 650 lbs > 260 lbs OK Wood Beam LIC# : KW-06011781, Build:20.25.05.07 Standley Structural Design (c) ENERCALC, LLC 1982-2025 DESCRIPTION:Roof Rafters (water heater enclosure) Project File: 2017 Greenleaf St.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900 900 1350 625 1600 580 180 575 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 2x6 Span = 3.0 ft 1 2 D(0.01995) Lr(0.0266) .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 1.330 ft, (Roof) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.051: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 1.500ft 9.24 psi= = 1,681.88psi 2x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 2x6 Maximum Shear Stress Ratio 0.041 : 1 0.000 ft= = 86.29psi Maximum Deflection 24566 <360 13518 Ratio =0 <180 Max Downward Transient Deflection 0.001 in 0 Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.003 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 3.0 ft 1 0.032 0.026 0.90 1.300 1.151.00 1.00 0.02 38.8 1,211.0 0.02 162.01.00 4.21.00 1.00+D+Lr 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 3.0 ft 1 0.051 0.041 1.25 1.300 1.151.00 1.00 0.05 86.3 1,681.9 0.05 225.01.00 9.21.00 1.00+D+0.750Lr 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 3.0 ft 1 0.044 0.035 1.25 1.300 1.151.00 1.00 0.05 74.4 1,681.9 0.04 225.01.00 8.01.00 1.00+0.60D 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 3.0 ft 1 0.011 0.009 1.60 1.300 1.151.00 1.00 0.01 23.3 2,152.8 0.01 288.01.00 2.51.00 . Wood Beam LIC# : KW-06011781, Build:20.25.05.07 Standley Structural Design (c) ENERCALC, LLC 1982-2025 DESCRIPTION:Roof Rafters (water heater enclosure) Project File: 2017 Greenleaf St.ec6 Project Title: Engineer: Project ID: Project Descr: LocationLoad CombinationMax. LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+Lr1 0.0027 1.511 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.073 0.073 Max Upward from Load Combinations 0.073 0.073 Max Upward from Load Cases 0.040 0.040 D Only 0.033 0.033 +D+Lr 0.073 0.073 +D+0.750Lr 0.063 0.063 +0.60D 0.020 0.020 Lr Only 0.040 0.040 Wood Beam LIC# : KW-06011781, Build:20.24.08.01 Standley Structural Design (c) ENERCALC INC 1983-2023 DESCRIPTION:HDR #1 Project File: 2017 Greenleaf St.ec6 Project Title: Engineer: Pro ect ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling llowable Stress Design Douglas Fir-Larch No.2 900 900 1350 625 1600 580 180 575 31.21 nalysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination SCE 7-16 Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 6.830 ft, (Roof) DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.524: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 4.000ft 49.38 psi= = 1,462.50psi 4x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 225.00 psi== Section used for this span 4x8 Maximum Shear Stress Ratio 0.219 : 1 7.416 ft= = 765.68psi Maximum Deflection 1348 <360 753 Ratio =0 <180 Max Downward Transient Deflection 0.071 in 0 Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.127 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 8.0 ft 1 0.321 0.135 0.90 1.300 1.001.00 1.00 0.86 338.0 1,053.0 0.37 162.01.00 21.81.00 1.00+D+Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.524 0.219 1.25 1.300 1.001.00 1.00 1.96 765.7 1,462.5 0.84 225.01.00 49.41.00 1.00+D+0.750Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.450 0.189 1.25 1.300 1.001.00 1.00 1.68 658.8 1,462.5 0.72 225.01.00 42.51.00 1.00+0.60D 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.108 0.045 1.60 1.300 1.001.00 1.00 0.52 202.8 1,872.0 0.22 288.01.00 13.11.00 Wood Beam LIC# : KW-06011781, Build:20.24.08.01 Standley Structural Design (c) ENERCALC INC 1983-2023 DESCRIPTION:HDR #1 Project File: 2017 Greenleaf St.ec6 Project Title: Engineer: Pro ect ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.1275 4.029 0.0000 0.000 Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.978 0.978 Max Upward from Load Combinations 0.978 0.978 Max Upward from Load Cases 0.546 0.546 D Only 0.432 0.432 +D+Lr 0.978 0.978 +D+0.750Lr 0.842 0.842 +0.60D 0.259 0.259 Lr Only 0.546 0.546 CITY OF SANTA ANA a o SCHoo�� Certificate of Compliance Payment of School Facility Fees Santa Ana Unified School District Name (First, M1, Last) ryce' mordo'f � Case Project Address City, State, Zip Code Name (First, MI, Last) 2UI'l I )anfiD' Thom N Green eaf S+. Aoxt.,, CA 92JO(o Use of Building (check) Residential[A CommercialEl Senior HousingE] Description of Project Number of Square Feet of Residential Space Abu 5iD4 Planning and Building Agency 5241�- Approved FOR PERMIT ISSUANCE Master ID: Telephone Date: Son 94LI.- AL4 - I 1'-18 Tract/Parcel Number i0112y083 Telephone Type of Project (check) New [ Addition ❑ Alteration ❑ e Con\qersicn Sq. Ft x S 5 -Ff (Dev. Fee) Number of Square Feet of Commercial Space Sq. Ft x S (Dev. Fee) Total s 2. q 15. 68 Total $ The above representations as to square footage are true. Applicant agrees that if it is later representations are not true, then this certificate shall automatically terminate, and the appropriate notified. Applicant is hereby noticed that any party filing a protest regarding the imposition Government Code Section 53080 must do so within 90 days from the payment of the fee. 1Z11� Applican 'ame (Please Print) Sikna4ure determined that such City/Count. shall be of fees pursuant to This certifies that the above -named Applicant has paid school facility fees in compliance with all existing and applicably sections of the Government Code and Education Code. San DISTRIBUTION White - City/County Canary -Applicant Pink - Facilities ized Representative trace 245