Loading...
HomeMy WebLinkAbout1951 E Carnegie Ave - Plan1 3 7 A C G A S2.00 337' ± 26 8 ' ± ST R U C T U R A L E N G I N E E R PR O J E C T I N F O R M A T I O N RTU Unit Replacement 1951 Carnegie Ave Santa Ana CA 92705 24-0417-00 SH E E T N U M B E R SH E E T T I T L E SH E E T I N F O JOB NUMBER: DRAWN: DESIGNED: CHECKED: ST A M P AP P R O V A L RR GD RLB SU B M I T T A L S A N D R E V I S I O N S ISSUE DATE: NO DATEDESCRIPTION SCALE: H: \ 2 0 2 4 \ 2 4 0 4 1 7 \ 3 _ D r a w i n g s \ D w g s - 0 0 \ 2 4 - 0 4 1 7 - 0 0 _ S 1 . 0 0 V I C I N I T Y M A P , S I T E P L A N , S T R U C T U R A L N O T E S , A N D A B B R E V I A T I O N S . d w g P L O T T E D B Y : Sh a w n A l v i r a O N : Ma r c h 1 1 , 2 0 2 5 03-11-2025 S1.00 VICINITY MAP, SITE PLAN, STRUCTURAL NOTES, AND ABBREVIATIONS NONE LONG BEACH • SAN DIEGO LONG BEACH OFFICE 3900 Cover Street, Long Beach CA 90808 • 562.985.3200 S T R U C T U R A L E N G I N SREE No.3503 L I GNE L S NO B A LAE A L I OFRNIA N E ER I E ET ORPD F E R IR L.KC E TS AT CFO RE G S I S URALTSRUCTPRO G R E S S - NO T F O R P L A N REV I E W VICINITY MAP SCALE: NONE SYMBOLS #POUND, NUMBER, QUANTITY @ AT <LESS THAN >GREATER THAN ±PLUS OR MINUS °DEGREE Ø DIAMETER ABBREVIATIONS AB ANCHOR BOLT ADDL ADDITIONAL ADJ ADJACENT ALT ALTERNATE APPROX APPROXIMATE, APPROXIMATELY ARCH ARCHITECT, ARCHITECTURAL BLKG BLOCKING, BLOCK BM BEAM BOT BOTTOM BTWN BETWEEN CALCS CALCULATIONS CG CENTER OF GRAVITY CL CENTERLINE CLR CLEAR, CLEARANCE COL COLUMN CONC CONCRETE CONN CONNECT, CONNECTION CONT CONTINUOUS DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DWG DRAWING (E)EXISTING EA EACH EF EACH FACE ELEC ELECTRICAL EMBED EMBED, EMBEDDED, EMBEDMENT EOR ENGINEER OF RECORD EQ EQUAL EQUIP EQUIPMENT EW EACH WAY EXP EXPANSION EXT EXTERIOR FDN FOUNDATION FTG FOOTING GA GAUGE GALV GALVANIZE HORIZ HORIZONTAL INFO INFORMATION KB-TZ2 HILTI KWIK BOLT TZ2 (ANCHOR) LBS POUNDS LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LOCS LOCATIONS LONG LONGITUDINAL LSH LONG SIDE HORIZONTAL LSV LONG SIDE VERTICAL MANUF MANUFACTURER MAX MAXIMUM MECH MECHANICAL MHP MHP STRUCTURAL ENGINEERS MIN MINIMUM (N)NEW N/A NOT APPLICABLE NTS NOT TO SCALE NWT NORMAL-WEIGHT OC ON CENTER OP OPERATING PEN PENETRATION PERP PERPENDICULAR PL PLATE, PROPERTY LINE QTY QUANTITY REINF REINFORCING REQD REQUIRE, REQUIRED SCHED SCHEDULE SEOR STRUCTURAL ENGINEER OF RECORD SHTG SHEATHING SIM SIMILAR SMS SHEET METAL SCREW SQ SQUARE SS STAINLESS STEEL STAGG STAGGER STIFF STIFFEN, STIFFENER STRUC STRUCTURAL SYM SYMMETRICAL T&B TOP & BOTTOM THK THICK, THICKNESS THRU THROUGH TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD W/WITH W/O WITHOUT WT WEIGHT ABBREVIATIONS: CODES/INSTITUTIONS/ASSOCIATIONS ACI AMERICAN CONCRETE INSTITUTE AF&PA (NDS) AMERICAN FOREST & PAPER ASSOCIATION (NDS) AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE APA-EWA APA-ENGINEERED WOOD ASSOCIATION ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AWS AMERICAN WELDING SOCIETY CBC CALIFORNIA BUILDING CODE NDS NATIONAL DESIGN SPECIFICATIONS SDI STEEL DECK INSTITUTE SJI STEEL JOIST INSTITUTE SSMA STEEL STUD MANUFACTURERS ASSOCIATION GENERAL STRUCTURAL NOTES: DESIGN CRITERIA: CODE OF RECORD:2022 EDITION, CALIFORNIA BUILDING CODE DESIGN LOADS: BASIC WIND SPEED 95 MPH (3-SECOND GUST) WIND EXPOSURE CATEGORY B ANALYSIS PROCEDURE SEISMIC DESIGN FOR NONSTRUCTURAL COMPONENTS (ASCE 7-16, CHAPTER 13) RISK CATEGORY II SEISMIC SITE CLASS D (DEFAULT) SEISMIC DESIGN CATEGORY D SPECTRAL RESPONSE ACCELERATIONS SS = 1.266, SDS = 1.013 SEISMIC IMPORTANCE FACTOR, IP 1.0 RTU UNIT WITH NEOPRENE PADS COMPONENT AMPLIFICATION FACTOR aP = 2.5 COMPONENT RESPONSE MODIFICATION FACTOR RP = 2.0 OVERSTRENGTH FACTOR Ω0 = 2.0 1.GOVERNING CODE AUTHORITY FOR THIS PROJECT: CITY OF SANTA ANA AND IS REFERRED TO AS “THE GOVERNING AGENCY” IN THESE AND OTHER STRUCTURAL NOTES SECTIONS. 2.GENERAL NOTES AND TYPICAL DETAILS SHALL APPLY TO ALL PARTS OF THE JOB, EXCEPT WHERE THEY MAY DIFFER WITH DETAILS AND NOTES ON OTHER SHEETS, IN WHICH CASE THE DETAILS AND NOTES ON OTHER SHEETS SHALL GOVERN. DETAIL MARKS WITH "SIM" NOTED INDICATES THAT DETAIL CONTAINS MODIFIED INFORMATION APPLICABLE TO THE CONDITION REFERENCED. 3.SEE MECHANICAL, ELECTRICAL OR PLUMBING (MEP) DRAWINGS FOR SIZE AND LOCATION OF ALL OPENINGS (EXCEPT AS NOTED), INSERTS, FINISHES, ETC., FOR DETAILS (EXCEPT AS SHOWN), AND FOR DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS. WHERE DIMENSIONS DIFFER BETWEEN PLANS, NOTIFY SEOR AND AWAIT DIRECTION PRIOR TO PROCEEDING WITH WORK. 4.DO NOT INSERT MECHANICAL, ELECTRICAL OR PLUMBING (MEP) SLEEVES, PIPES OR CONDUIT IN CONCRETE WITHOUT PRIOR APPROVAL OF THE SEOR, TYPICAL UNLESS NOTED OTHERWISE ON PLAN. 5.OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE SEOR PRIOR TO PROCEEDING WITH ANY WORK INVOLVED. 6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT AND THE SEOR AND SHALL BE RESOLVED PRIOR TO PROCEEDING WITH THE WORK. 7.ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST CURRENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE SEOR SO THAT THE PROPER REVISION MAY BE MADE. MODIFICATIONS OF CONSTRUCTION DETAILS SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL OF THE SEOR. 8.THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHOD OR SEQUENCE OF CONSTRUCTION, UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING BUT NOT LIMITED TO BRACING, SHORING AND LAYDOWN OF CONSTRUCTION MATERIALS. 9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY CONSTRUCTION LOADING, INCLUDING LOADING FROM EQUIPMENT SUCH AS SKIP LOADERS, SCISSOR LIFTS, ETC., ON ALL PORTIONS OF THE STRUCTURE, WHETHER ELEVATED OR ON-GRADE. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE PATH-OF-TRAVEL FOR MOVING PERMANENT EQUIPMENT TO ITS FINAL LOCATION; INCLUDING THE EFFECTS OF TEMPORARY LOADING AS THE EQUIPMENT IS INSTALLED. THE CONTRACTOR MAY USE THE “DESIGN LOADS” INFORMATION PROVIDED ABOVE WHEN CONSIDERING TEMPORARY CONSTRUCTION LOADING CONDITIONS. 10.OBSERVATION VISITS TO THE SITE BY FIELD REPRESENTATIVES OF THE ARCHITECT/SEOR SHALL NOT INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES OF THE CONSTRUCTION PROCEDURES. ANY SUPPORT SERVICES PERFORMED BY THE ARCHITECT/SEOR DURING THE CONSTRUCTION SHALL BE DISTINGUISHED FROM CONTINUOUS AND DETAILED SPECIAL INSPECTION SERVICES WHICH ARE FURNISHED BY OTHERS. THESE SUPPORT SERVICES PERFORMED BY THE ARCHITECT/SEOR, WHETHER OF MATERIAL OR WORK, AND WHETHER PERFORMED PRIOR TO, DURING OR AFTER COMPLETION OF CONSTRUCTION, ARE PERFORMED SOLELY FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL AND IN ACHIEVING CONFORMANCE WITH CONTRACT DOCUMENTS, BUT DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE, AND SHALL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION. 11.ASTM DESIGNATIONS AND ALL STANDARDS REFER TO THE LATEST ADOPTED AMENDMENTS. 12.WHEN THE ALLOWANCE FOR SUBSTITUTION OF A SPECIFIED MATERIAL OR PRODUCT DESIGNATION IS IMPLIED ON THE DESIGN DRAWINGS BY THE USE OF THE WORDS "OR APPROVED EQUAL", APPROVAL SHALL BE OBTAINED FROM THE SEOR AND THE GOVERNING AGENCY PRIOR TO FABRICATION OR INSTALLATION OF THE SUBSTITUTED MATERIAL OR PRODUCT. 13.DIMENSIONS SHALL GOVERN OVER SCALES SHOWN ON DRAWINGS. 14.THE OWNER SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS WHO SHALL PROVIDE SPECIAL INSPECTIONS DURING CONSTRUCTION WHEN SO SPECIFIED ON THE CONTRACT DRAWINGS AND SPECIFICATIONS FOR CERTAIN TYPES OF WORK. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE HIS COMPETENCE, TO THE SATISFACTION OF THE GOVERNING AGENCY, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH THE DESIGN DRAWINGS AND SPECIFICATIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE SEOR AND TO THE GOVERNING AGENCY. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE SEOR AND TO THE GOVERNING AGENCY. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF HIS KNOWLEDGE, IN CONFORMANCE WITH THE DESIGN DRAWINGS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISION OF THE CODE AND OTHER APPLICABLE REGULATIONS IDENTIFIED ON THE PLANS OR IN THE PROJECT SPECIFICATIONS. 15.UNLESS SPECIFICALLY SHOWN ON THESE PLANS, NO STRUCTURAL MEMBER (BEAM, COLUMN, SHEARWALL, GRADE BEAM, ETC.) SHALL BE CUT, DRILLED OR NOTCHED WITHOUT PRIOR AUTHORIZATION FROM THE SEOR AND THE GOVERNING AGENCY. 16.DIMENSIONS OF EQUIPMENT ANCHOR/ MOUNTING LOCATIONS AND SIZE OF ANCHORAGE BRACKETS SHOWN ON PLANS AND/OR DETAILS ARE TO BE COORDINATED WITH ACTUAL EQUIPMENT TO BE INSTALLED. CONTRACTOR TO VERIFY THE EXACT SIZE AND LOCATION OF ALL EQUIPMENT ANCHOR/ MOUNTING HOLES LOCATIONS AND SIZE OF ANCHORAGE BRACKETS PRIOR TO INSTALLATION. WHERE ACTUAL EQUIPMENT DIMENSIONS DO NOT FALL WITHIN THE MINIMUM OR MAXIMUM DIMENSIONS PROVIDED ON PLANS AND/OR DETAILS OR THE ANCHORAGE BRACKETS ARE NOT THE CORRECT SIZE TO ALLOW FOR PROPER INSTALLATION OF THE EQUIPMENT, NOTIFY SEOR AND AWAIT DIRECTION PRIOR TO PROCEEDING WITH WORK. FRAMING LUMBER: 1.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR-LARCH, WEST COAST (WCDF) OF THE FOLLOWING MINIMUM GRADES (UNLESS NOTED OTHERWISE): A.PLATES, BLOCKING, 2X FRAMING AND 2X6 STUDS AND LARGER = NO. 2 B.2X4 STUDDING = CONSTRUCTION GRADE C.BEAMS, HEADERS, POSTS AND OTHER 4X OR LARGER MEMBERS (UNO) = NO. 1 2.STRUCTURAL PLYWOOD SHALL BE DOUGLAS FIR CONFORMING TO UNITED STATES PRODUCT STANDARD PS-1-19 EXPOSURE I, MARKED STRUCTURAL I AND SHALL BE STAMPED BY AN APPROVED FABRICATOR. 3.REDBUILT LAMINATED LUMBER SHALL BE SERIES LVL BEAM/JOIST AND INSTALLATION SHALL CONFORM TO ICC ESR-2993. ALLOWABLE DESIGN VALUES SHALL BE: FB = 2,900 PSI FC (PERPENDICULAR) = 750 PSI FV = 285 PSI FC (PARALLEL) = 2,635 PSI FT = 1,660 PSI E = 2X106 PSI 4.TRUS JOIST LAMINATED LUMBER SHALL BE 2.0E PARALLAM PSL, AND INSTALLATION SHALL CONFORM TO ICC ESR-1387. ALLOWABLE DESIGN VALUES SHALL BE: FB = 2,900 PSI FC (PERPENDICULAR) = 625 PSI FV = 290 PSI FC (PARALLEL) = 2,900 PSI FT = 2,025 PSI E = 2X106 PSI 5.EQUAL LAMINATED LUMBER MAY BE SUBSTITUTED PROVIDED GRADING AGENCY REPORT FOR SUBSTITUTION HAS EQUIVALENT OR GREATER ALLOWABLE DESIGN VALUES. GRADING AGENCY REPORT AND EQUIVALENT MEMBERS SHALL BE SUBMITTED TO STRUCTURAL ENGINEER FOR APPROVAL. 6.“STRUCTURAL WALLS” WHERE CALLED OUT IN THE DRAWINGS REFERS TO SHEAR WALLS, EXTERIOR WALLS, AND/OR BEARING WALLS. 7.CONTRACTOR SHALL COORDINATE SPECIAL INSPECTIONS AND CONSTRUCTION SCHEDULE SO THAT ALL ELEMENTS REQUIRING SPECIAL INSPECTION MAY BE OBSERVED BY THE SPECIAL INSPECTOR PRIOR TO INSTALLATION OF COVERING MATERIAL. 8.FRAMING ON WHICH THE DIAPHRAGM AND SHEAR WALL SHEATHING IS INSTALLED SHALL BE OF THE SIZE AND GRADE AND MOISTURE CONTENT SPECIFIED. WET LUMBER SHALL BE ALLOWED TO AIR DRY TO COMPLY WITH THE SPECIFIED MOISTURE CONTENT UNDER WHICH IT IS GRADED, PRIOR TO COVERING WITH SHEATHING. SPACING OF FRAMING MEMBERS SHALL BE AS SPECIFIED AND ACCURATELY MAINTAINED SO AS TO ENSURE ADEQUATE EDGE AND END DISTANCES. WHERE ADEQUATE EDGE OR END DISTANCES ARE NOT OBTAINED, THE FRAMING SHALL BE ADJUSTED OR THE SHEATHING TRIMMED TO SECURE PROPER END AND EDGE DISTANCES AND OTHER CLEARANCES. FRAMING OBSERVED TO HAVE BEEN SPLIT BY FASTENERS SHALL BE REPLACED AND THE SHEATHING REFASTENED. 9.SHEATHING SHALL BE OF THE TYPE, THICKNESS AND GRADE CALLED FOR ON THE PLANS. ALTERNATE SHEATHING MATERIAL SHALL NOT BE USED WITHOUT THE WRITTEN AUTHORIZATION OF THE SEOR. 10.FASTENERS USED TO CONNECT SHEATHING TO UNDERLYING FRAMING SHALL BE OF THE SIZE SPECIFIED ON THE PLANS, INSTALLED AT THE CENTER-TO-CENTER SPACING NOTED THEREIN. FASTENERS SHALL BE INSTALLED AT THE MINIMUM DISTANCE FROM THE EDGE OR END OF THE DIAPHRAGM OR SHEAR WALL SHEATHING. THE FASTENER HEAD SHALL BE DRIVEN FLUSH BUT SHALL NOT FRACTURE THE SURFACE OF THE SHEATHING. FASTENERS SHALL BE STAGGERED ALONG THE UNDERLYING FRAMING MEMBERS TO THE EXTENT PERMITTED BY EDGE AND END DISTANCE REQUIREMENTS. FASTENERS SHALL PENETRATE THROUGH THE SHEATHING AND INTO SOLID FRAMING OR BLOCKING BEHIND. INCORRECTLY FASTENED SHEATHING SHALL BE IDENTIFIED AND REPAIRED AS DIRECTED BY THE SEOR. 11.BLOCKING CALLED FOR AT THE UNSUPPORTED EDGES OF PANEL SHEATHING AND ELSEWHERE, SHALL BE OF THE THICKNESS AND GRADE OF MATERIAL SPECIFIED AND/OR NOTED. BLOCKING BETWEEN WOOD MEMBERS SHALL BE SNUGLY FIT. BLOCKING OBSERVED TO HAVE BEEN SPLIT BY THE FASTENERS SHALL BE REPLACED AND SHEATHING REFASTENED. 12.NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY SHOWN, NOTED OR APPROVED BY THE SEOR. 13.MAXIMUM MOISTURE CONTENT FOR 2X FRAMING SHALL NOT EXCEED 19 PERCENT (19%) AT TIME OF COVER-UP (COVER-UP INCLUDES APPLICATION OF PLYWOOD OR GYPBOARD). 2X FRAMING SHALL BE STAMPED “S-DRY” OR “KD”. FOR PROJECTS NOT GOVERNED BY DSA OR OSHPD, 2X FRAMING MAY BE STAMPED “S-GREEN”. MOISTURE CONTENT OF 2X FRAMING SHALL BE TESTED AND INSPECTED PER FRAMED LUMBER SPECIAL INSPECTION NOTES. 14.BOLT HOLE DIAMETER SHALL BE THE DIAMETER OF BOLT PLUS 1/16" UNLESS NOTED OTHERWISE. PROVIDE WASHERS UNDER HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. ALL BOLTS SHALL BE RE-TIGHTENED JUST PRIOR TO COVER-UP. 15.PRESERVATIVE-TREATED WOOD (I.E. PROTECTED AGAINST DECAY OR INSECT ATTACK) SHALL BE USED FOR WOOD FRAMING MEMBERS WHICH FORM THE STRUCTURAL SUPPORTS OF BUILDINGS, BALCONIES, PORCHES OR SIMILAR PERMANENT BUILDING APPURTENANCES WHEN SUCH MEMBERS ARE EITHER IN CONTACT WITH CONCRETE OR MASONRY OR ARE EXPOSED TO THE WEATHER WITHOUT ADEQUATE PROTECTION FROM A ROOF, EAVE, OVERHANG OR OTHER COVERING TO PREVENT MOISTURE OR WATER ACCUMULATION ON THE SURFACE OR AT JOINTS BETWEEN MEMBERS. WHERE MEMBERS ARE FIELD CUT, DRILLED, NOTCHED OR OTHERWISE ALTERED IN THE FIELD, ALL AFFECTED SURFACES SHALL BE RE-TREATED. 16.WOOD FRAMING TO BE PRESERVATIVE-TREATED SHALL CONFORM TO THE REQUIREMENTS OF THE AWPA STANDARD U1 AND APPLICABLE AWPA UC STANDARDS FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE. THESE WOOD MEMBERS SHALL BEAR THE QUALITY MARK OF AN INSPECTION AGENCY THAT MAINTAINS CONTINUING SUPERVISION, TESTING AND INSPECTION OVER THE QUALITY OF THE PRESERVATIVE-TREATED WOOD. 17.WHERE PRESERVATIVE-TREATED WOOD IS USED IN ENCLOSED LOCATIONS WHERE DRYING IN SERVICE CANNOT READILY OCCUR, SUCH WOOD SHALL BE AT A MOISTURE CONTENT OF 19 PERCENT (19%) OR LESS BEFORE BEING COVERED WITH INSULATION, INTERIOR WALL FINISH, FLOOR COVERING OR OTHER MATERIALS. 18.FRAMING HANGERS, CAPS, HOLDOWNS, POST BASES, ANCHORS, CONNECTORS, ETC., SHALL BE AS MANUFACTURED BY "SIMPSON COMPANY" OR APPROVED EQUAL TO BE SUBMITTED TO STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. NAIL OPTIONS THAT SIMPSON PROVIDES FOR FULL CONNECTOR VALUE OTHER THAN COMMON WIRE MAY BE USED. 19.FASTENERS INCLUDING NUTS AND WASHERS IN INTERIOR LOCATIONS IN CONTACT WITH PRESERVATIVE-TREATED WOOD MEMBERS SHALL BE OF HOT-DIPPED ZINC-COATED GALVANIZED STEEL (ASTM A-153), STAINLESS STEEL, SILICON BRONZE OR COPPER, EXCEPT THAT ANCHOR BOLTS MAY BE IN ADDITION OF MECHANICALLY DEPOSITED ZINC-COATED STEEL (ASTM B-695, CLASS 55 MINIMUM). WHERE FASTENERS IN INTERIOR LOCATIONS (EXCLUDING EXTERIOR WALL SILL PLATES) IN CONTACT WITH ZINC BORATE PRESERVATIVE-TREATED WOOD MAY BE PLAIN CARBON STEEL. 20.NAILS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F-1667. NAILS SHALL BE COMMON WIRE (UNO) AND THE NUMBER OF NAILS CONNECTING WOOD MEMBERS SHALL BE PER THE PLANS AND DETAILS BUT NOT LESS THAN THE AMOUNTS SET FORTH IN TYPICAL WOOD FASTENING SCHEDULE IN THE DRAWINGS. GALVANIZED COMMON NAILS SHALL BE USED FOR ALL EXPOSED EXTERIOR WOOD. COMMON NAILS SHALL CONFORM TO THE SPECIFICATIONS OF NAIL PROPERTIES SCHEDULE BELOW: 21.TOE NAILS SHALL BE DRIVEN AT AN ANGLE OF APPROXIMATELY 30 DEGREES WITH THE MEMBER AND STARTED APPROXIMATELY 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END. 22.SEE SPECIAL INSPECTION NOTES FOR INSPECTION REQUIREMENTS. NAIL PROPERTIES SCHEDULE DESIGNATION LENGTH WIRE DIAMETER HEAD DIAMETER 6d 2"0.113"0.266" 8d 2 1/2"0.131"0.281" 10d 3"0.148"0.312" 12d 3 1/4"0.148"0.312" 16d 3 1/2"0.162"0.344" 20d 4"0.192"0.406" NOTE: 10d COMMON SHORT (2 1/8" LONG) MAY BE USED AT 1/2" AND THINNER PLYWOOD IN LIEU OF 10d COMMON (3") OR 8d COMMON (2 1/2" LONG). NAILING SHALL NOT BREAK THROUGH OUTER PLY OF PLYWOOD. IF PNEUMATIC GUNS ARE USED, THEY SHALL BE ADJUSTED TO SATISFY THE ABOVE CRITERIA. SPECIAL INSPECTIONS: 1.THE OWNER, OR THE OWNER'S AUTHORIZED AGENT (OTHER THAN THE CONTRACTOR AS APPLICABLE) SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS, INCLUDING AS APPLICABLE AN INSPECTOR OF RECORD (IOR), WHO SHALL PROVIDE SPECIAL INSPECTIONS DURING CONSTRUCTION FOR CERTAIN TYPES OF WORK WHEN SO SPECIFIED IN THE CONTRACT DOCUMENTS AND PROJECT SPECIFICATIONS. WHERE AN IOR IS REQUIRED BY THE GOVERNING AGENCY, THE IOR MAY PERFORM SPECIAL INSPECTIONS IF THAT PERSON IS QUALIFIED PER THE GOVERNING AGENCY'S STANDARDS FOR THE SPECIAL INSPECTION REQUIRED. WHERE AN IOR IS NOT REQUIRED, THESE SPECIAL INSPECTIONS SHALL BE IN ADDITION TO AND COMPLEMENTARY WITH THE INSPECTIONS PROVIDED BY THE GOVERNING AGENCY. 2.THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON FROM AN APPROVED AGENCY CONFORMING TO ASTM C1077 WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE ARCHITECT, STRUCTURAL ENGINEER OF RECORD AND THE GOVERNING AGENCY, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. 3.THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH THE DESIGN DRAWINGS, SPECIFICATIONS AND APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE AND OTHER APPLICABLE REGULATIONS IDENTIFIED WITHIN THE CONSTRUCTION DOCUMENTS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE GENERAL CONTRACTOR FOR CORRECTION AND THEN, IF UNCORRECTED, TO THE ATTENTION OF THE ARCHITECT, STRUCTURAL ENGINEER OF RECORD AND THE GOVERNING AGENCY. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE SPECIAL INSPECTOR AND SCHEDULE THE SPECIAL INSPECTIONS WITH ADEQUATE TIME TO ADDRESS ANY AND ALL POTENTIAL DISCREPANCIES PRIOR TO PROCEEDING WITH SUBSEQUENT WORK THAT COVERS OR OTHERWISE MAKES INACCESSIBLE ANY WORK IDENTIFIED AS DEVIATING FROM THE PROJECT REQUIREMENTS. 4.THE SPECIAL INSPECTOR SHALL FURNISH REGULAR INSPECTION REPORTS TO THE ARCHITECT, STRUCTURAL ENGINEER OF RECORD AND THE GOVERNING AGENCY IDENTIFYING THE WORK INSPECTED AND ANY UNCORRECTED DISCREPANCIES FROM THE CONSTRUCTION DOCUMENTS. AT THE CONCLUSION OF THE PROJECT OR THE SPECIAL INSPECTORS ASSIGNED SCOPE OF WORK, THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF HIS OR HER KNOWLEDGE, COMPLETED IN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS (INCLUDING APPROVED RFI'S, ADDENDUMS, ETC.) AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE AND OTHER APPLICABLE REGULATIONS IDENTIFIED WITHIN THE CONSTRUCTION DOCUMENTS. 5.UNLESS NOTED OTHERWISE, SPECIAL INSPECTIONS INDICATED BELOW SHALL BE PROVIDED IN EITHER A CONTINUOUS OR PERIODIC CAPACITY, AS DEFINED BELOW, AS REQUIRED BY THE INDIVIDUAL CODE OR REFERENCED STANDARD. 6.CONTINUOUS - SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS PRESENT WHEN AND WHERE THE WORK TO BE INSPECTED IS BEING PERFORMED. 7.PERIODIC - SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. FOR STRUCTURAL STEEL, PERIODIC INSPECTION IS FURTHER DEFINED SUCH THAT ITEMS ARE OBSERVED ON A RANDOM BASIS. 8.FOR STRUCTURAL STEEL WELDING AND BOLTING, SPECIAL INSPECTION SHALL BE PROVIDED IN EITHER AN OBSERVE OR PERFORM CAPACITY AS DEFINED BELOW: ·OBSERVE (O) - INSPECTOR SHALL OBSERVE THESE ITEMS ON A RANDOM BASIS ·PERFORM (P) - INSPECTOR SHALL OBSERVE OR PERFORM SPECIFIED TASK FOR EACH WELDED OR BOLTED JOINT OR MEMBER 9.QUALITY CONTROL (QC) INSPECTION TASKS SHALL BE PERFORMED BY THE FABRICATOR'S OR ERECTOR'S QC INSPECTOR (QCI) AS INDICATED. QUALITY ASSURANCE (QA) INSPECTION TASKS SHALL BE PERFORMED BY THE QA INSPECTOR (QAI) AS INDICATED. WHEN A TASK IS INDICATED TO BE PERFORMED BY BOTH THE QAI AND QCI, COORDINATION IS PERMITTED SO THAT THE INSPECTION FUNCTIONS ARE PERFORMED BY ONLY ONE PARTY. WHEN THE QAI RELIES ON THE QCI, THE APPROVAL OF THE SEOR AND AGENCY HAVING JURISDICTION IS REQUIRED. 10.THE FOLLOWING CONSTRUCTION ELEMENTS AND MATERIALS SHALL BE INSPECTED AND EVALUATED BY A SPECIAL INSPECTOR IN ACCORDANCE WITH THE NOTED CBC SECTIONS AND REFERENCED STANDARDS, WHERE ELEMENTS AND MATERIALS ARE PRESENT ON THE PROJECT. SEE GENERAL NOTES FOR EACH MATERIAL FOR ADDITIONAL REQUIREMENTS, IN ADDITION TO TABLES AND NOTES BELOW: FRAMED LUMBER SPECIAL INSPECTION NOTES: 1.MOISTURE CONTENT OF 2X FRAMING SHALL BE TESTED WITH A MOISTURE METER HAVING ONE INCH (1”) NEEDLE IN THE PRESENCE OF A SPECIAL INSPECTOR. STRUCTURAL AND MISCELLANEOUS STEEL: 1.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS (AISC 360). 2.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL CONFORM TO THE FOLLOWING SPECIFICATION (UNLESS NOTED OTHERWISE): A.ANGLES AND PLATES ASTM A-36 FY=36KSI 3.AFTER FABRICATION, ALL STEEL SHALL BE CLEANED FREE OF RUST, LOOSE MILL SCALE, AND OIL. 4.ALL STEEL EXPOSED TO MOISTURE OR WEATHER SHALL BE HOT-DIPPED GALVANIZED, UNLESS NOTED OTHERWISE. GALVANIZING SHALL BE IN CONFORMANCE WITH ASTM A123 AND A153. REPAIR GALVANIZING AFTER WELDING SHALL BE IN ACCORDANCE WITH ASTM A780. 5.WHERE CARBON STEEL IS IN CONTACT WITH STAINLESS STEEL OR WHERE EITHER CARBON OR STAINLESS STEEL IS IN CONTACT WITH ALUMINUM, PHENOLIC SHIM OR BREAK SHALL BE INSTALLED TO SEPARATE DISSIMILAR METALS. SCOPE OF WORK: MECHANICAL AND STRUCTURAL SCOPE OF WORK CONSISTS OF REPLACING THREE AIR HANDLING UNITS AT THE SUBJECT PROJECT ROOF. PROJECT LOCATION: 1951 CARNEGIE AVE SANTA ANA, CA 92705 SITE PLAN SCALE: NONE C A R N E G I E A V E N U E KEY PLAN SCALE: 1/32" = 1'-0" (E) 1-STORY BUILDING ±89,000 SQ FT BUILDING OWNER: Name:LBA/PFF Industrial – Carnegie, LLC Address:3347 Michelson Dr. Suite 200 Irvine, CA 92612 Phone: (949) 648-0741 Email: cjimenez@lbarealty.com PL PL PL PL 25 ' ± 40' ± 10 5 ' ± 88' ± No.3503 L I GNE L S NO B A LAE A L I OFRNIA N E ER I E ET ORPD F E R IR L.KC E TS AT CFO RE G S I S URALTSRUCT Exp. 3/31/2026 Bldg #101122969 APPROVALS: PLNG - C. Santana POLICE - B. Martin PUBLIC WORKS - Y. Soto (E ) 5 1 / 8 x 2 4 G L B (E ) 5 1 / 8 x 2 4 G L B (E ) 5 1 / 8 x 2 4 G L B (E ) 5 1 / 8 x 2 4 G L B (E ) 5 1 / 8 x 2 7 G L B , T Y P (E ) 5 1 / 8 x 2 7 G L B , T Y P (E ) 5 1 / 8 x 2 7 G L B , T Y P (E) 6 3/4x43 1/2 GLB, TYP (E) 6 3/4x30 GLB, TYP (E) 6 3/4x36 GLB, TYP (E) 6 3/4x43 1/2 GLB, TYP (E) 6 3/4x30 GLB, TYP (E) 6 3/4x36 GLB, TYP (E) 4x12 @ 8"OC, TYP(E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP (E) 2x @ 24"OC. TYP (E) 1/2" PLYWOOD ROOF SHEATHING, VIF RTU 8 MAX OP WT=586# RTU 2 MAX OP WT=455# RTU 13 MAX OP WT=586# 1 S2.00TYP (E) DUCT OPENING, TYP (E) UNIT WHERE OCCURS, TYP (E) SCREEN WALL, TYP (NEW) (NEW) (NEW) 62 ' - 0 " ± (E ) 5 1 / 8 x 2 7 G L B , T Y P 3 4 5 6 7 48 ' - 0 " ± V I F 42 ' - 0 " ± V I F 42 ' - 0 " ± V I F 45 ' - 0 " ± V I F A B C 60'-0"± VIF 60'-0"± VIF SCALE:S2.00 ROOF INFILL AT EXISTING OPENING (WHERE OCCURS)2 1 1/2" = 1'-0" (E) SIMPSON HANGER, TYP VIF (E) OPENING (9'-6" MAX) (E ) O P E N I N G (4 ' - 6 " M A X ) NOTE: PROVIDE 10d NAILS @ 6"OC AT ALL (N) PLY EDGES & @ 12"OC EN (E) 2x JOIST PER PLAN, TYP (E) JOIST PER PLAN (E) ROOF SHEATHING PER PLAN (E) SHEATHING (N) SHEATHING EN ROOF SHEATHING PER PLAN SECTION A-A A A 2x PER PLAN 2x BLKG PER PLAN 2x6 @ 24"OC MAX SIMPSON LU26 FACE HANGER EA END, TYP 2x6 BLKG W/ (4)-10d NAILS TO (E) JOIST, TYP (E) (2)-2x 1/2" STRUC PLY SHTG 2x6 BLKG W/ 10d NAILS @ 6"OC, TYP SCALE:S2.00 LINE OF SITE 3 NONE 6' - 0 " 300'-0" 29 ' - 0 " 62'-0"± 4' - 7 " MA X SECTION (WHERE SCREEN WALL OCCURS) 2' - 0 " 4' - 7 " M A X NOTE: LINE OF SITE IS ADEQUATE FOR THE NEW UNIT BEING REPLACED THAT IS NOT CURRENTLY BEHIND A SCREEN WALL BASED ON THE EXISTING FIELD DIMENSIONS AS SHOWN. BELOW PARAPET SCALE:S2.00 RTU UNIT ANCHORAGE 1 1/2" = 1'-0" PLAN VIEW AT BASE L2 M I N W2 MIN L3x3x3/16 x0'-4" LONG W/ (3)-#12 SMS TO UNIT & 1/2"Ø LAG SCREW (3" MIN PEN) TO 4x BELOW, TYP EA CORNER AS SHOWN (4 TOTAL) 6" MA X TY P 8" MA X H M A X W1±L1± (E) PLYWOOD ROOF SHEATHING PER PLAN (E) 2x JOIST PER PLAN, TYP SIMP A35, SLEEPER TO SLEEPER, EA CORNER (E) 4x MEMBER WHERE OCCURS PER PLAN 4x SLEEPER (FIELD VERIFY DEPTH), TYP ALL 4 SIDES 1/2" PLYWOOD W/ 10d @ 6",6",12 (BN,EN,FN) ANCHOR PER PLAN VIEW, TYP A A RTU UNIT PER PLAN, MAX OP WT=SEE SCHED SIMP A34, TYP EA SIDE, EA END 2 3/4" MIN 8" MAX TYP 2" TYP 4x6 BLKG W/ SIMP A35 EA SIDE, EA END, TYP AT SLEEPER ANGLES 4x6 W/ SIMP A34 EA SIDE, EA END, TYP AT ANGLES AS SHOWN 2x6 @ 16"OC W/ SIMP A34 EA SIDE, EA END, TYP UNO L3x3x12GA x0'-6" BENT PL W/ (2)-1/2"Ø LAG SCREWS (3" MIN PEN) TO SLEEPER & (2)-1/2"Ø LAG SCREWS (4" MIN PEN) TO 4x BLOCK, TYP EA END OF SLEEPER AS SHOWN SECTION A-A 8'-0" MAX TYP EQ TYP EQ TYP EQ TYP NEOPRENE PAD PER MECH, TYP UNDER EA ANCHOR (E) GLB WHERE OCCURS PER PLAN EQUIPMENT SCHEDULE UNIT MAX OP WT H W1 L1 W2 L2 RTU-2 455#49"44"48"47"36" RTU-8, 13 586#34"46"74"49"62" SCALE:S2.00 ROOF INFILL AT EXISTING OPENING (WHERE OCCURS)2 1 1/2" = 1'-0" (E) SIMPSON HANGER, TYP VIF (E) OPENING (9'-6" MAX) (E ) O P E N I N G (4 ' - 6 " M A X ) NOTE: PROVIDE 10d NAILS @ 6"OC AT ALL (N) PLY EDGES & @ 12"OC EN (E) 2x JOIST PER PLAN, TYP (E) JOIST PER PLAN (E) ROOF SHEATHING PER PLAN (E) SHEATHING (N) SHEATHING EN ROOF SHEATHING PER PLAN SECTION A-A A A 2x PER PLAN 2x BLKG PER PLAN 2x6 @ 24"OC MAX SIMPSON LU26 FACE HANGER EA END, TYP 2x6 BLKG W/ (4)-10d NAILS TO (E) JOIST, TYP (E) (2)-2x 1/2" STRUC PLY SHTG 2x6 BLKG W/ 10d NAILS @ 6"OC, TYP SCALE:S2.00 LINE OF SITE 3 NONE 6' - 0 " 300'-0" 29 ' - 0 " 62'-0"± 4' - 7 " MA X SECTION (WHERE SCREEN WALL OCCURS) 2' - 0 " 4' - 7 " M A X NOTE: LINE OF SITE IS ADEQUATE FOR THE NEW UNIT BEING REPLACED THAT IS NOT CURRENTLY BEHIND A SCREEN WALL BASED ON THE EXISTING FIELD DIMENSIONS AS SHOWN. BELOW PARAPET SCALE:S2.00 RTU UNIT ANCHORAGE 1 1/2" = 1'-0" PLAN VIEW AT BASE L2 M I N W2 MIN L3x3x3/16 x0'-4" LONG W/ (3)-#12 SMS TO UNIT & 1/2"Ø LAG SCREW (3" MIN PEN) TO 4x BELOW, TYP EA CORNER AS SHOWN (4 TOTAL) 6" MA X TY P 8" MA X H M A X W1±L1± (E) PLYWOOD ROOF SHEATHING PER PLAN (E) 2x JOIST PER PLAN, TYP SIMP A35, SLEEPER TO SLEEPER, EA CORNER (E) 4x MEMBER WHERE OCCURS PER PLAN 4x SLEEPER (FIELD VERIFY DEPTH), TYP ALL 4 SIDES 1/2" PLYWOOD W/ 10d @ 6",6",12 (BN,EN,FN) ANCHOR PER PLAN VIEW, TYP A A RTU UNIT PER PLAN, MAX OP WT=SEE SCHED SIMP A34, TYP EA SIDE, EA END 2 3/4" MIN 8" MAX TYP 2" TYP 4x6 BLKG W/ SIMP A35 EA SIDE, EA END, TYP AT SLEEPER ANGLES 4x6 W/ SIMP A34 EA SIDE, EA END, TYP AT ANGLES AS SHOWN 2x6 @ 16"OC W/ SIMP A34 EA SIDE, EA END, TYP UNO L3x3x12GA x0'-6" BENT PL W/ (2)-1/2"Ø LAG SCREWS (3" MIN PEN) TO SLEEPER & (2)-1/2"Ø LAG SCREWS (4" MIN PEN) TO 4x BLOCK, TYP EA END OF SLEEPER AS SHOWN SECTION A-A 8'-0" MAX TYP EQ TYP EQ TYP EQ TYP NEOPRENE PAD PER MECH, TYP UNDER EA ANCHOR (E) GLB WHERE OCCURS PER PLAN EQUIPMENT SCHEDULE UNIT MAX OP WT H W1 L1 W2 L2 RTU-2 455#49"44"48"47"36" RTU-8, 13 586#34"46"74"49"62" ST R U C T U R A L E N G I N E E R PR O J E C T I N F O R M A T I O N RTU Unit Replacement 1951 Carnegie Ave Santa Ana, CA, 92705 24-0417-00 SH E E T N U M B E R SH E E T T I T L E SH E E T I N F O JOB NUMBER: DRAWN: DESIGNED: CHECKED: ST A M P AP P R O V A L RR GD RLB SU B M I T T A L S A N D R E V I S I O N S ISSUE DATE: NO DATEDESCRIPTION SCALE: H: \ 2 0 2 4 \ 2 4 0 4 1 7 \ 3 _ D r a w i n g s \ D w g s - 0 0 \ 2 4 - 0 4 1 7 - 0 0 _ S 2 . 0 0 P A R T I A L R O O F F R A M I N G P L A N , S E C T I O N S , A N D D E T A I L S . d w g P L O T T E D B Y : Ru b e n R u i z O N : Fe b r u a r y 5 , 2 0 2 5 10-14-2024 S2.00 PARTIAL ROOF FRAMING PLAN, SECTIONS, AND DETAILS AS NOTED LONG BEACH • SAN DIEGO LONG BEACH OFFICE 3900 Cover Street, Long Beach CA 90808 • 562.985.3200 S T R U C T U R A L E N G I N SREE No.3503 L I GNE L S NO B A LAE A L I OFRNIA N E ER I E ET ORPD F E R IR L.KC E TS AT CFO RE G S I S URALTSRUCTPRO G R E S S - NO T F O R P L A N REV I E W SCALE:S2.00 PARTIAL ROOF FRAMING PLAN A 1/8" = 1'-0" 1.SEE GENERAL NOTES SHEET(S) FOR APPLICABLE NOTES & ABBREVIATIONS. SEE PROJECT SPECIFICATIONS WHERE APPLICABLE FOR ADDITIONAL INFORMATION. 2.EXISTING CONSTRUCTION IS SHOWN FADED AND IS LABELED AS EXISTING OR (E). NEW CONSTRUCTION IS SHOWN DARK AND IS SPECIFICALLY REFERENCED BY DETAILS AND NOTES. 3.EXISTING CONDITIONS ARE SHOWN TO THE BEST OF OUR KNOWLEDGE. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ACTUAL CONDITIONS. DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THOSE SHOWN ON THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING. 4.DIMENSIONS OF EQUIPMENT ANCHOR/ MOUNTING LOCATIONS SHOWN ON PLANS AND/OR DETAILS ARE TO BE COORDINATED WITH ACTUAL EQUIPMENT TO BE INSTALLED. 5.CONTRACTOR TO VERIFY THE EXACT SIZE AND LOCATION OF ALL EQUIPMENT ANCHOR/ MOUNTING HOLES PRIOR TO INSTALLATION. WHERE ACTUAL EQUIPMENT DIMENSIONS DO NOT FALL WITHIN THE MINIMUM OR MAXIMUM DIMENSIONS PROVIDED ON PLANS AND/OR DETAILS, NOTIFY SEOR AND AWAIT DIRECTION PRIOR TO PROCEEDING WITH WORK. 6.DO NOT CUT ANY NEW OPENINGS OR ENLARGE ANY EXISTING OPENINGS IN THE ROOF OR WALLS (FOR DUCTS, PIPES, ETC.) UNLESS SPECIFICALLY SHOWN ON THESE STRUCTURAL DRAWINGS. 7.MAXIMUM OPERATING WEIGHTS NOTED ON THE PLANS INCLUDE THE WEIGHT OF UNIT PLUS ALL ACCESSORIES, CURBS, ISOLATORS, ETC. THAT ARE ASSOCIATED WITH THE UNIT. FRAMING PLAN NOTES No.3503 L I GNE L S NO B A LAE A L I OFRNIA N E ER I E ET ORPD F E R IR L.KC E TS AT CFO RE G S I S URALTSRUCT Exp. 3/31/2026 MHP JN: 24-0417-00 3347 Michelson Drive, Suite 200 Irvine, CA 92612 by MHP, Inc. Structural Engineers 3900 Cover St. Long Beach, California 90808 October 30, 2024 1951 Carnegie Ave. Santa Ana, CA 92705 for LBA Realty, LLC HVAC Replacement STRUCTURAL CALCULATIONS for No.3503 L I GNE L S NO B A LAE A L I OFRNIA N E ER I E ET ORPD F E R IR L.KC E TS AT CFO RE G S I S URALTSRUCT                           !"  #$%#&'()*+,-+&./+0&1(*2(&.*(0&'.&$345%0&61. 7(2-289+0&7:*,-289+;&<<=4#5##>?0&@##4=A>#%<A# B(2+ CDEFEGDGHGIDHIGJKL B+M-,*&':9+&N+O+)+*P+&B:P8Q+*2 RSTUVCW N-MX&'(2+,:)Y ZZ 1-2+&'[(MM \V\]  CC H J^ _Y`+ a([8+ B+MP)-`2-:* C GWW LSTb     ] D G   ^ C D HcH LSTb     ] C D ^ LC cG  V        LC V  CC H F  V        \C DCJ d      D G  R \C V  CC H F d      C D  R _Y`+ a([8+ B+MP)-`2-:* \S V  CC H F       e fC G       D G  f V  CC H F       C D  KR D cJH LST!     fKR C G       KR KRL D WHC     !     gh F h V        bg C GWW K     !V      ]D G  ^ i C JcF f     Vj ]Gk   e "    cDe^    \ C UUl f           ]D G  ^ Cbg D HcH K     !V      ]C D  ^ Ci D HFF f     Vj ]Gk   e "    cDe^    C\ D WDl f           ]C D  ^ KR D UGl f           ]K!  R  ^ 1.0 Weight Comparison of (N) Equipment vs Original Equipment: Per 2019 California Existing Building Code (2019 CEBC): Initially, compare new unit weight to existing unit weight. If greater than 5%, compare load increase against the original full design load on the member. If still greater than 5%, bring member up to current code, strengthening as necessary. Unit ID Orig Unit Weight (lbs) (N) Unit Weight (lbs)% Increase Conclusion Status AC-2 450 455 1.1% < 5% Increase O.K. AC-8 590 586 -0.7% No Increase O.K. AC-13 560 586 4.6% < 5% Increase O.K. H:\2024\240417\4_Engineering\240417.Equip Anchorage 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 2.0 OCT 2024 SEISMIC FACTORS FOR EQUIPMENT ANCHORAGE Site: Floor (Level): Equipment: Seismic Design Force Factors: ap* Rp* o Ip z h SDS** amp factor response mod factor Omega (overstrength) Factor importance factor height of attach point average roof height design parameter at short periods 2.5 2 2 1.0 1 1 1.013 * ASCE 7-16, Table 13.5-1, 13.6-1 **See seismic coefficients on US Seismic Design Maps output Seismic Design Force for Equipment Anchorage 1.52 Wp (ASCE 7-16, Equation 13.3-1) 1.62 Wp (ASCE 7-16, Equation 13.3-2) 0.30 Wp (ASCE 7-16, Equation 13.3-3) Seismic Design Force Fp(H) =1.52 Wp 1.06 Wp Fp (V) = .2SDS 0.20 Wp 0.14 Wp (ASCE 7-16, Section 13.3.1.2) Overstrength Forces (Anchorage into Concrete (LRFD)) 3o*Fp(H)=3.04 Wp 2.13 Wp *No overstrength required for F p(V) ASD (0.7 x LRFD)LRFD LRFD ASD (0.7 x LRFD) 1951 Carnegie Ave., Santa Ana, CA 92705 Roof Air Handling Units w/ Neoprene Pads = 0.4  / 1 + 2  ℎ= (min)= 0.3  = (max)= 1.6  = H:\2024\240417\4_Engineering\240417.Equip Anchorage 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 3.0 OCT 2024 DESIGN WIND PRESSURE FOR ROOFTOP UNITS (per ASCE 7-16 Sec. 29.4) Wind Coefficients Basic Wind Speed V =95 mph Risk Category =II (Table 1.5-1) Exposure Category =B (Sec 26.7) Wind Directionality Factor Kd =0.85 (Table 26.6-1) Velocity Pressure Exposure Coefficient Kz =0.76 (Table 26.10-1) Are the site and location conditions in Sec. 6.5.7.1 met?No K1 =1.00 (Figure 26.8-1) K2 =1.00 (Figure 26.8-1) K3 =1.00 (Figure 26.8-1) Topographic Factor Kzt =1.00 (Figure 26.8-1) Ground Elevation Factor Ke =1.00 (Table 26.9-1) ASCE 7-16 Sec 29.4.1 Rooftop Structures and Equipment for Buildings: Design velocity pressure qz = 0.00256 Kz Kzt Kd Ke V2 =14.9 psf (Eq. 26.10-1) Minimum design wind pressure Pnet-min =16 psf (Sec 29.7) Lateral GCr =1.9 (Sec 29.4.1) Vertical GCr =1.5 (Sec 29.4.1) Lateral Force Fh = qh(GCr)Af =28 psf (Eq. 29.4-2) Vertical Uplift Force Fv = qh(GCr)Ar =22 psf (Eq. 29.4-3) Wind Design Force FH =28 psf 17 psf FV =22 psf 13 psf LRFD ASD (0.6 x LRFD) H:\2024\240417\4_Engineering\240417.Equip Anchorage 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 4.0 OCT 2024 Floor Mounted Equipment Anchor Forces (ASD) Unit Properties Unit Unit and Curb Weight, Wp =586 lbs Equipment Width, WE =46 in Equipment Length, LE =74 in Anchorage Width, WA =49 in Anchorage Length, LA =62 in Height, H =34 in Center of Projected Area, CA =17 in Anchor Layout Nanchors, W = Each Side, Parallel to W 2 Nanchors, L = Each Side, Parallel to L 2 Shared Corner Anchors (If YES, then 100+30 considered)YES NAnchors, Total = 4 Forces on Unit (ASD) Design Wind Force, Fh =17.0 psf Design Wind Force, FV =13.4 psf Total Horiz Force, Hw (Parallel to W) = Fh*H*LE = 297 lbs Total Horiz Force, Hw (Parallel to L) = Fh*H*WE = 185 lbs Total Vertical Force, Tw = Fv*WE*LE = 318 lbs Overtunring Parallel to W Mult = HW*H/2 =5.1 k-in Mresist = .6*Wp*WA/2 =8.6 k-in Overtunring Parallel to L Mult = HW*H/2 =3 k-in Mresist = .6*Wp*WA/2 =11 k-in Forces on Anchors (ASD) Tult (OT Parallel to W) =+FV =43 lbs NAnchors, Total Tult (OT Parallel to L) =+FV =17 lbs NAnchors, Total Tult (ASD) =Tult (OT Parallel to W) ==43 lbs Vult (ASD) =HW (MAX) / NAnchors, Total =74 lbs (LA * Nanchors, W) AC-8, 13 ( Mult - Mresist ) (WA * Nanchors, L) ( Mult - Mresist ) H:\2024\240417\4_Engineering\240417.Equip Anchorage 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com **Seismic Governs 5.0 OCT 2024 Floor Mounted Equipment Anchor Forces (ASD) Unit Properties Unit Wp =586 lbs Anchorage Width, W =49 in Anchorage Length, L =62 in Height, H =34 in CG =23 in Anchor Layout Nanchors, W = Each Side, Parallel to W 2 Nanchors, L = Each Side, Parallel to L 2 Shared Corner Anchors (If YES, then 100+30 considered)YES NAnchors, Total = 4 Forces on Unit (ASD) Fp(H) =1.06 *Wp= 623 lb Fp(V) =0.14 *Wp= 83 lb Mult = Fp(H)*CG =14 k-in Mresist (OT Parallel to W) =.6*Wp*W/2 =9 k-in Mresist (OT Parallel to L) =.6*Wp*L/2 =11 k-in Forces on Anchors (ASD) Tult (OT Parallel to W) =+Fp(V)=77 lbs NAnchors, Total Tult (OT Parallel to L) =+Fp(V)=47 lbs NAnchors, Total Tult (100+30) ==91 lbs Tult (ASD) =Tult (100+30) ==91 lbs Vult (ASD) =Fp(H) / NAnchors, Total =156 lbs 1.0*Tmax+0.3*Tmin AC-8, 13 ( Mult - Mresist (OT parallel to W) ) (W * Nanchors, L) (Mult - Mresist (OT parallel to L) ) (L * Nanchors, W) H:\2024\240417\4_Engineering\240417.Equip Anchorage 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com **Anchors Good by Inspection 6.0 OCT 2024 Floor Mounted Equipment Anchor Forces (ASD) Unit Properties Unit Unit and Curb Weight, Wp =455 lbs Equipment Width, WE =44 in Equipment Length, LE =48 in Anchorage Width, WA =47 in Anchorage Length, LA =36 in Height, H =49 in Center of Projected Area, CA =25 in Anchor Layout Nanchors, W = Each Side, Parallel to W 2 Nanchors, L = Each Side, Parallel to L 2 Shared Corner Anchors (If YES, then 100+30 considered)YES NAnchors, Total = 4 Forces on Unit (ASD) Design Wind Force, Fh =17.0 psf Design Wind Force, FV =13.4 psf Total Horiz Force, Hw (Parallel to W) = Fh*H*LE = 278 lbs Total Horiz Force, Hw (Parallel to L) = Fh*H*WE = 255 lbs Total Vertical Force, Tw = Fv*WE*LE = 197 lbs Overtunring Parallel to W Mult = HW*H/2 =6.8 k-in Mresist = .6*Wp*WA/2 =6.4 k-in Overtunring Parallel to L Mult = HW*H/2 =6 k-in Mresist = .6*Wp*WA/2 =5 k-in Forces on Anchors (ASD) Tult (OT Parallel to W) =+FV =53 lbs NAnchors, Total Tult (OT Parallel to L) =+FV =68 lbs NAnchors, Total Tult (ASD) =Tult (OT Parallel to L) ==68 lbs Vult (ASD) =HW (MAX) / NAnchors, Total =69 lbs AC-2 ( Mult - Mresist ) (WA * Nanchors, L) ( Mult - Mresist ) (LA * Nanchors, W) H:\2024\240417\4_Engineering\240417.Equip Anchorage 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com **Seismic Governs 7.0 OCT 2024 Floor Mounted Equipment Anchor Forces (ASD) Unit Properties Unit Wp =455 lbs Anchorage Width, W =36 in Anchorage Length, L =47 in Height, H =49 in CG =33 in Anchor Layout Nanchors, W = Each Side, Parallel to W 2 Nanchors, L = Each Side, Parallel to L 2 Shared Corner Anchors (If YES, then 100+30 considered)YES NAnchors, Total = 4 Forces on Unit (ASD) Fp(H) =1.06 *Wp= 484 lb Fp(V) =0.14 *Wp= 65 lb Mult = Fp(H)*CG =16 k-in Mresist (OT Parallel to W) =.6*Wp*W/2 =5 k-in Mresist (OT Parallel to L) =.6*Wp*L/2 =6 k-in Forces on Anchors (ASD) Tult (OT Parallel to W) =+Fp(V)=167 lbs NAnchors, Total Tult (OT Parallel to L) =+Fp(V)=116 lbs NAnchors, Total Tult (100+30) ==202 lbs Tult (ASD) =Tult (100+30) ==202 lbs Vult (ASD) =Fp(H) / NAnchors, Total =121 lbs 1.0*Tmax+0.3*Tmin AC-2 ( Mult - Mresist (OT parallel to W) ) (W * Nanchors, L) (Mult - Mresist (OT parallel to L) ) (L * Nanchors, W) H:\2024\240417\4_Engineering\240417.Equip Anchorage 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 8.0 OCT 2024 Anchorage of Rooftop Equipment ME Unit Parameters Unit: Unit Length, L =48 in Unit Width,=44 in Top of Unit (Height)=49 in Unit & Curb Weight =455 lbs Max Tension Force: (From Previous Sheet) Tult (ASD)= 202 lbs (ASD) Withdraw Capacity 1/2" dia. Lag Screw =378 lbs/in Penetration =3.0 Number of Lag Screws (long. side)=1 Capacity of Lag Screws =1134 lbs OK Max Shear Force: (From Previous Sheet) Vult (ASD)= 121 lbs (ASD) Shear Capacity 1/2" dia. Lag Screw =290 lbs Number of Lag Screws (total)=1 Capacity of Lag Screws =290 lbs OK Combined Lateral & Withdrawal Loading P (penetration)=3.0 in Z = sqrt(V2 + T2)= 236 lbs α (angle) = tan-1 (T/V) = 59 deg Wp = W1 x P = = 1134 lbs Wp' = CD x Wp = 1.6 x 1701#= 1814 lbs Z (single shear)=290 lbs Z' = CD x Z = 1.6 x 290# = 464 lbs Zα' = Wp' x Z' / Wp'cos(α)2 + Z'sin(α)2 = 1027 lbs OK AC-2 H:\2024\240417\4_Engineering\240417.Equip Anchorage 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 9.0 OCT 2024 ST R U C T U R A L E N G I N E E R PR O J E C T I N F O R M A T I O N AC Unit Replacement 1951 Carnegie Ave Santa Ana, CA, 92705 24-0417-00 SH E E T N U M B E R SH E E T T I T L E SH E E T I N F O JOB NUMBER: DRAWN: DESIGNED: CHECKED: ST A M P AP P R O V A L RR GD RLB SU B M I T T A L S A N D R E V I S I O N S ISSUE DATE: NO DATEDESCRIPTION SCALE: H: \ 2 0 2 4 \ 2 4 0 4 1 7 \ 3 _ D r a w i n g s \ D w g s - 0 0 \ 2 4 - 0 4 1 7 - 0 0 _ S 1 . 0 S T R U C T U R A L N O T E S A N D A B B R E V I A T I O N S . d w g P L O T T E D B Y : Ru b e n R u i z O N : Oc t o b e r 1 8 , 2 0 2 4 10-30-2024 S1.00 STRUCTURAL NOTES AND ABBREVIATIONS NONE LONG BEACH • SAN DIEGO LONG BEACH OFFICE 3900 Cover Street, Long Beach CA 90808 • 562.985.3200 S T R U C T U R A L E N G I N SREE No.3503 L I GNE L S NO B A LAE A L I OFRNIA N E ER I E ET ORPD F E R IR L.KC E TS AT CFO RE G S I S URALTSRUCTPRO G R E S S - NO T F O R P L A N REV I E W SYMBOLS #POUND, NUMBER, QUANTITY @ AT <LESS THAN >GREATER THAN ±PLUS OR MINUS °DEGREE Ø DIAMETER ABBREVIATIONS AB ANCHOR BOLT ADDL ADDITIONAL ADJ ADJACENT ALT ALTERNATE APPROX APPROXIMATE, APPROXIMATELY ARCH ARCHITECT, ARCHITECTURAL BLKG BLOCKING, BLOCK BM BEAM BOT BOTTOM BTWN BETWEEN CALCS CALCULATIONS CG CENTER OF GRAVITY CL CENTERLINE CLR CLEAR, CLEARANCE COL COLUMN CONC CONCRETE CONN CONNECT, CONNECTION CONT CONTINUOUS DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DWG DRAWING (E)EXISTING EA EACH EF EACH FACE ELEC ELECTRICAL EMBED EMBED, EMBEDDED, EMBEDMENT EOR ENGINEER OF RECORD EQ EQUAL EQUIP EQUIPMENT EW EACH WAY EXP EXPANSION EXT EXTERIOR FDN FOUNDATION FTG FOOTING GA GAUGE GALV GALVANIZE HORIZ HORIZONTAL INFO INFORMATION KB-TZ2 HILTI KWIK BOLT TZ2 (ANCHOR) LBS POUNDS LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LOCS LOCATIONS LONG LONGITUDINAL LSH LONG SIDE HORIZONTAL LSV LONG SIDE VERTICAL MANUF MANUFACTURER MAX MAXIMUM MECH MECHANICAL MHP MHP STRUCTURAL ENGINEERS MIN MINIMUM (N)NEW N/A NOT APPLICABLE NTS NOT TO SCALE NWT NORMAL-WEIGHT OC ON CENTER OP OPERATING PEN PENETRATION PERP PERPENDICULAR PL PLATE, PROPERTY LINE QTY QUANTITY REINF REINFORCING REQD REQUIRE, REQUIRED SCHED SCHEDULE SEOR STRUCTURAL ENGINEER OF RECORD SHTG SHEATHING SIM SIMILAR SMS SHEET METAL SCREW SQ SQUARE SS STAINLESS STEEL STAGG STAGGER STIFF STIFFEN, STIFFENER STRUC STRUCTURAL SYM SYMMETRICAL T&B TOP & BOTTOM THK THICK, THICKNESS THRU THROUGH TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD W/WITH W/O WITHOUT WT WEIGHT ABBREVIATIONS: CODES/INSTITUTIONS/ASSOCIATIONS ACI AMERICAN CONCRETE INSTITUTE AF&PA (NDS) AMERICAN FOREST & PAPER ASSOCIATION (NDS) AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE APA-EWA APA-ENGINEERED WOOD ASSOCIATION ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AWS AMERICAN WELDING SOCIETY CBC CALIFORNIA BUILDING CODE NDS NATIONAL DESIGN SPECIFICATIONS SDI STEEL DECK INSTITUTE SJI STEEL JOIST INSTITUTE SSMA STEEL STUD MANUFACTURERS ASSOCIATION GENERAL STRUCTURAL NOTES: DESIGN CRITERIA: CODE OF RECORD:2022 EDITION, CALIFORNIA BUILDING CODE DESIGN LOADS: BASIC WIND SPEED 95 MPH (3-SECOND GUST) WIND EXPOSURE CATEGORY B ANALYSIS PROCEDURE SEISMIC DESIGN FOR NONSTRUCTURAL COMPONENTS (ASCE 7-16, CHAPTER 13) RISK CATEGORY II SEISMIC SITE CLASS D (DEFAULT) SEISMIC DESIGN CATEGORY D SPECTRAL RESPONSE ACCELERATIONS SS = 1.266, SDS = 1.013 SEISMIC IMPORTANCE FACTOR, IP 1.0 AC UNIT WITH NEOPRENE PADS COMPONENT AMPLIFICATION FACTOR aP = 2.5 COMPONENT RESPONSE MODIFICATION FACTOR RP = 2.0 OVERSTRENGTH FACTOR Ω0 = 2.0 1.GOVERNING CODE AUTHORITY FOR THIS PROJECT: CITY OF SANTA ANA AND IS REFERRED TO AS “THE GOVERNING AGENCY” IN THESE AND OTHER STRUCTURAL NOTES SECTIONS. 2.GENERAL NOTES AND TYPICAL DETAILS SHALL APPLY TO ALL PARTS OF THE JOB, EXCEPT WHERE THEY MAY DIFFER WITH DETAILS AND NOTES ON OTHER SHEETS, IN WHICH CASE THE DETAILS AND NOTES ON OTHER SHEETS SHALL GOVERN. DETAIL MARKS WITH "SIM" NOTED INDICATES THAT DETAIL CONTAINS MODIFIED INFORMATION APPLICABLE TO THE CONDITION REFERENCED. 3.SEE MECHANICAL, ELECTRICAL OR PLUMBING (MEP) DRAWINGS FOR SIZE AND LOCATION OF ALL OPENINGS (EXCEPT AS NOTED), INSERTS, FINISHES, ETC., FOR DETAILS (EXCEPT AS SHOWN), AND FOR DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS. WHERE DIMENSIONS DIFFER BETWEEN PLANS, NOTIFY SEOR AND AWAIT DIRECTION PRIOR TO PROCEEDING WITH WORK. 4.DO NOT INSERT MECHANICAL, ELECTRICAL OR PLUMBING (MEP) SLEEVES, PIPES OR CONDUIT IN CONCRETE WITHOUT PRIOR APPROVAL OF THE SEOR, TYPICAL UNLESS NOTED OTHERWISE ON PLAN. 5.OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE SEOR PRIOR TO PROCEEDING WITH ANY WORK INVOLVED. 6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT AND THE SEOR AND SHALL BE RESOLVED PRIOR TO PROCEEDING WITH THE WORK. 7.ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST CURRENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE SEOR SO THAT THE PROPER REVISION MAY BE MADE. MODIFICATIONS OF CONSTRUCTION DETAILS SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL OF THE SEOR. 8.THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHOD OR SEQUENCE OF CONSTRUCTION, UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING BUT NOT LIMITED TO BRACING, SHORING AND LAYDOWN OF CONSTRUCTION MATERIALS. 9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY CONSTRUCTION LOADING, INCLUDING LOADING FROM EQUIPMENT SUCH AS SKIP LOADERS, SCISSOR LIFTS, ETC., ON ALL PORTIONS OF THE STRUCTURE, WHETHER ELEVATED OR ON-GRADE. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE PATH-OF-TRAVEL FOR MOVING PERMANENT EQUIPMENT TO ITS FINAL LOCATION; INCLUDING THE EFFECTS OF TEMPORARY LOADING AS THE EQUIPMENT IS INSTALLED. THE CONTRACTOR MAY USE THE “DESIGN LOADS” INFORMATION PROVIDED ABOVE WHEN CONSIDERING TEMPORARY CONSTRUCTION LOADING CONDITIONS. 10.OBSERVATION VISITS TO THE SITE BY FIELD REPRESENTATIVES OF THE ARCHITECT/SEOR SHALL NOT INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES OF THE CONSTRUCTION PROCEDURES. ANY SUPPORT SERVICES PERFORMED BY THE ARCHITECT/SEOR DURING THE CONSTRUCTION SHALL BE DISTINGUISHED FROM CONTINUOUS AND DETAILED SPECIAL INSPECTION SERVICES WHICH ARE FURNISHED BY OTHERS. THESE SUPPORT SERVICES PERFORMED BY THE ARCHITECT/SEOR, WHETHER OF MATERIAL OR WORK, AND WHETHER PERFORMED PRIOR TO, DURING OR AFTER COMPLETION OF CONSTRUCTION, ARE PERFORMED SOLELY FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL AND IN ACHIEVING CONFORMANCE WITH CONTRACT DOCUMENTS, BUT DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE, AND SHALL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION. 11.ASTM DESIGNATIONS AND ALL STANDARDS REFER TO THE LATEST ADOPTED AMENDMENTS. 12.WHEN THE ALLOWANCE FOR SUBSTITUTION OF A SPECIFIED MATERIAL OR PRODUCT DESIGNATION IS IMPLIED ON THE DESIGN DRAWINGS BY THE USE OF THE WORDS "OR APPROVED EQUAL", APPROVAL SHALL BE OBTAINED FROM THE SEOR AND THE GOVERNING AGENCY PRIOR TO FABRICATION OR INSTALLATION OF THE SUBSTITUTED MATERIAL OR PRODUCT. 13.DIMENSIONS SHALL GOVERN OVER SCALES SHOWN ON DRAWINGS. 14.THE OWNER SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS WHO SHALL PROVIDE SPECIAL INSPECTIONS DURING CONSTRUCTION WHEN SO SPECIFIED ON THE CONTRACT DRAWINGS AND SPECIFICATIONS FOR CERTAIN TYPES OF WORK. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE HIS COMPETENCE, TO THE SATISFACTION OF THE GOVERNING AGENCY, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH THE DESIGN DRAWINGS AND SPECIFICATIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE SEOR AND TO THE GOVERNING AGENCY. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE SEOR AND TO THE GOVERNING AGENCY. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF HIS KNOWLEDGE, IN CONFORMANCE WITH THE DESIGN DRAWINGS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISION OF THE CODE AND OTHER APPLICABLE REGULATIONS IDENTIFIED ON THE PLANS OR IN THE PROJECT SPECIFICATIONS. 15.UNLESS SPECIFICALLY SHOWN ON THESE PLANS, NO STRUCTURAL MEMBER (BEAM, COLUMN, SHEARWALL, GRADE BEAM, ETC.) SHALL BE CUT, DRILLED OR NOTCHED WITHOUT PRIOR AUTHORIZATION FROM THE SEOR AND THE GOVERNING AGENCY. 16.DIMENSIONS OF EQUIPMENT ANCHOR/ MOUNTING LOCATIONS AND SIZE OF ANCHORAGE BRACKETS SHOWN ON PLANS AND/OR DETAILS ARE TO BE COORDINATED WITH ACTUAL EQUIPMENT TO BE INSTALLED. CONTRACTOR TO VERIFY THE EXACT SIZE AND LOCATION OF ALL EQUIPMENT ANCHOR/ MOUNTING HOLES LOCATIONS AND SIZE OF ANCHORAGE BRACKETS PRIOR TO INSTALLATION. WHERE ACTUAL EQUIPMENT DIMENSIONS DO NOT FALL WITHIN THE MINIMUM OR MAXIMUM DIMENSIONS PROVIDED ON PLANS AND/OR DETAILS OR THE ANCHORAGE BRACKETS ARE NOT THE CORRECT SIZE TO ALLOW FOR PROPER INSTALLATION OF THE EQUIPMENT, NOTIFY SEOR AND AWAIT DIRECTION PRIOR TO PROCEEDING WITH WORK. FRAMING LUMBER: 1.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR-LARCH, WEST COAST (WCDF) OF THE FOLLOWING MINIMUM GRADES (UNLESS NOTED OTHERWISE): A.PLATES, BLOCKING, 2X FRAMING AND 2X6 STUDS AND LARGER = NO. 2 B.2X4 STUDDING = CONSTRUCTION GRADE C.BEAMS, HEADERS, POSTS AND OTHER 4X OR LARGER MEMBERS (UNO) = NO. 1 2.STRUCTURAL PLYWOOD SHALL BE DOUGLAS FIR CONFORMING TO UNITED STATES PRODUCT STANDARD PS-1-19 EXPOSURE I, MARKED STRUCTURAL I AND SHALL BE STAMPED BY AN APPROVED FABRICATOR. 3.REDBUILT LAMINATED LUMBER SHALL BE SERIES LVL BEAM/JOIST AND INSTALLATION SHALL CONFORM TO ICC ESR-2993. ALLOWABLE DESIGN VALUES SHALL BE: FB = 2,900 PSI FC (PERPENDICULAR) = 750 PSI FV = 285 PSI FC (PARALLEL) = 2,635 PSI FT = 1,660 PSI E = 2X106 PSI 4.TRUS JOIST LAMINATED LUMBER SHALL BE 2.0E PARALLAM PSL, AND INSTALLATION SHALL CONFORM TO ICC ESR-1387. ALLOWABLE DESIGN VALUES SHALL BE: FB = 2,900 PSI FC (PERPENDICULAR) = 625 PSI FV = 290 PSI FC (PARALLEL) = 2,900 PSI FT = 2,025 PSI E = 2X106 PSI 5.EQUAL LAMINATED LUMBER MAY BE SUBSTITUTED PROVIDED GRADING AGENCY REPORT FOR SUBSTITUTION HAS EQUIVALENT OR GREATER ALLOWABLE DESIGN VALUES. GRADING AGENCY REPORT AND EQUIVALENT MEMBERS SHALL BE SUBMITTED TO STRUCTURAL ENGINEER FOR APPROVAL. 6.“STRUCTURAL WALLS” WHERE CALLED OUT IN THE DRAWINGS REFERS TO SHEAR WALLS, EXTERIOR WALLS, AND/OR BEARING WALLS. 7.CONTRACTOR SHALL COORDINATE SPECIAL INSPECTIONS AND CONSTRUCTION SCHEDULE SO THAT ALL ELEMENTS REQUIRING SPECIAL INSPECTION MAY BE OBSERVED BY THE SPECIAL INSPECTOR PRIOR TO INSTALLATION OF COVERING MATERIAL. 8.FRAMING ON WHICH THE DIAPHRAGM AND SHEAR WALL SHEATHING IS INSTALLED SHALL BE OF THE SIZE AND GRADE AND MOISTURE CONTENT SPECIFIED. WET LUMBER SHALL BE ALLOWED TO AIR DRY TO COMPLY WITH THE SPECIFIED MOISTURE CONTENT UNDER WHICH IT IS GRADED, PRIOR TO COVERING WITH SHEATHING. SPACING OF FRAMING MEMBERS SHALL BE AS SPECIFIED AND ACCURATELY MAINTAINED SO AS TO ENSURE ADEQUATE EDGE AND END DISTANCES. WHERE ADEQUATE EDGE OR END DISTANCES ARE NOT OBTAINED, THE FRAMING SHALL BE ADJUSTED OR THE SHEATHING TRIMMED TO SECURE PROPER END AND EDGE DISTANCES AND OTHER CLEARANCES. FRAMING OBSERVED TO HAVE BEEN SPLIT BY FASTENERS SHALL BE REPLACED AND THE SHEATHING REFASTENED. 9.SHEATHING SHALL BE OF THE TYPE, THICKNESS AND GRADE CALLED FOR ON THE PLANS. ALTERNATE SHEATHING MATERIAL SHALL NOT BE USED WITHOUT THE WRITTEN AUTHORIZATION OF THE SEOR. 10.FASTENERS USED TO CONNECT SHEATHING TO UNDERLYING FRAMING SHALL BE OF THE SIZE SPECIFIED ON THE PLANS, INSTALLED AT THE CENTER-TO-CENTER SPACING NOTED THEREIN. FASTENERS SHALL BE INSTALLED AT THE MINIMUM DISTANCE FROM THE EDGE OR END OF THE DIAPHRAGM OR SHEAR WALL SHEATHING. THE FASTENER HEAD SHALL BE DRIVEN FLUSH BUT SHALL NOT FRACTURE THE SURFACE OF THE SHEATHING. FASTENERS SHALL BE STAGGERED ALONG THE UNDERLYING FRAMING MEMBERS TO THE EXTENT PERMITTED BY EDGE AND END DISTANCE REQUIREMENTS. FASTENERS SHALL PENETRATE THROUGH THE SHEATHING AND INTO SOLID FRAMING OR BLOCKING BEHIND. INCORRECTLY FASTENED SHEATHING SHALL BE IDENTIFIED AND REPAIRED AS DIRECTED BY THE SEOR. 11.BLOCKING CALLED FOR AT THE UNSUPPORTED EDGES OF PANEL SHEATHING AND ELSEWHERE, SHALL BE OF THE THICKNESS AND GRADE OF MATERIAL SPECIFIED AND/OR NOTED. BLOCKING BETWEEN WOOD MEMBERS SHALL BE SNUGLY FIT. BLOCKING OBSERVED TO HAVE BEEN SPLIT BY THE FASTENERS SHALL BE REPLACED AND SHEATHING REFASTENED. 12.NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY SHOWN, NOTED OR APPROVED BY THE SEOR. 13.MAXIMUM MOISTURE CONTENT FOR 2X FRAMING SHALL NOT EXCEED 19 PERCENT (19%) AT TIME OF COVER-UP (COVER-UP INCLUDES APPLICATION OF PLYWOOD OR GYPBOARD). 2X FRAMING SHALL BE STAMPED “S-DRY” OR “KD”. FOR PROJECTS NOT GOVERNED BY DSA OR OSHPD, 2X FRAMING MAY BE STAMPED “S-GREEN”. MOISTURE CONTENT OF 2X FRAMING SHALL BE TESTED AND INSPECTED PER FRAMED LUMBER SPECIAL INSPECTION NOTES. 14.BOLT HOLE DIAMETER SHALL BE THE DIAMETER OF BOLT PLUS 1/16" UNLESS NOTED OTHERWISE. PROVIDE WASHERS UNDER HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. ALL BOLTS SHALL BE RE-TIGHTENED JUST PRIOR TO COVER-UP. 15.PRESERVATIVE-TREATED WOOD (I.E. PROTECTED AGAINST DECAY OR INSECT ATTACK) SHALL BE USED FOR WOOD FRAMING MEMBERS WHICH FORM THE STRUCTURAL SUPPORTS OF BUILDINGS, BALCONIES, PORCHES OR SIMILAR PERMANENT BUILDING APPURTENANCES WHEN SUCH MEMBERS ARE EITHER IN CONTACT WITH CONCRETE OR MASONRY OR ARE EXPOSED TO THE WEATHER WITHOUT ADEQUATE PROTECTION FROM A ROOF, EAVE, OVERHANG OR OTHER COVERING TO PREVENT MOISTURE OR WATER ACCUMULATION ON THE SURFACE OR AT JOINTS BETWEEN MEMBERS. WHERE MEMBERS ARE FIELD CUT, DRILLED, NOTCHED OR OTHERWISE ALTERED IN THE FIELD, ALL AFFECTED SURFACES SHALL BE RE-TREATED. 16.WOOD FRAMING TO BE PRESERVATIVE-TREATED SHALL CONFORM TO THE REQUIREMENTS OF THE AWPA STANDARD U1 AND APPLICABLE AWPA UC STANDARDS FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE. THESE WOOD MEMBERS SHALL BEAR THE QUALITY MARK OF AN INSPECTION AGENCY THAT MAINTAINS CONTINUING SUPERVISION, TESTING AND INSPECTION OVER THE QUALITY OF THE PRESERVATIVE-TREATED WOOD. 17.WHERE PRESERVATIVE-TREATED WOOD IS USED IN ENCLOSED LOCATIONS WHERE DRYING IN SERVICE CANNOT READILY OCCUR, SUCH WOOD SHALL BE AT A MOISTURE CONTENT OF 19 PERCENT (19%) OR LESS BEFORE BEING COVERED WITH INSULATION, INTERIOR WALL FINISH, FLOOR COVERING OR OTHER MATERIALS. 18.FRAMING HANGERS, CAPS, HOLDOWNS, POST BASES, ANCHORS, CONNECTORS, ETC., SHALL BE AS MANUFACTURED BY "SIMPSON COMPANY" OR APPROVED EQUAL TO BE SUBMITTED TO STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. NAIL OPTIONS THAT SIMPSON PROVIDES FOR FULL CONNECTOR VALUE OTHER THAN COMMON WIRE MAY BE USED. 19.FASTENERS INCLUDING NUTS AND WASHERS IN INTERIOR LOCATIONS IN CONTACT WITH PRESERVATIVE-TREATED WOOD MEMBERS SHALL BE OF HOT-DIPPED ZINC-COATED GALVANIZED STEEL (ASTM A-153), STAINLESS STEEL, SILICON BRONZE OR COPPER, EXCEPT THAT ANCHOR BOLTS MAY BE IN ADDITION OF MECHANICALLY DEPOSITED ZINC-COATED STEEL (ASTM B-695, CLASS 55 MINIMUM). WHERE FASTENERS IN INTERIOR LOCATIONS (EXCLUDING EXTERIOR WALL SILL PLATES) IN CONTACT WITH ZINC BORATE PRESERVATIVE-TREATED WOOD MAY BE PLAIN CARBON STEEL. 20.NAILS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F-1667. NAILS SHALL BE COMMON WIRE (UNO) AND THE NUMBER OF NAILS CONNECTING WOOD MEMBERS SHALL BE PER THE PLANS AND DETAILS BUT NOT LESS THAN THE AMOUNTS SET FORTH IN TYPICAL WOOD FASTENING SCHEDULE IN THE DRAWINGS. GALVANIZED COMMON NAILS SHALL BE USED FOR ALL EXPOSED EXTERIOR WOOD. COMMON NAILS SHALL CONFORM TO THE SPECIFICATIONS OF NAIL PROPERTIES SCHEDULE BELOW: 21.TOE NAILS SHALL BE DRIVEN AT AN ANGLE OF APPROXIMATELY 30 DEGREES WITH THE MEMBER AND STARTED APPROXIMATELY 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END. 22.SEE SPECIAL INSPECTION NOTES FOR INSPECTION REQUIREMENTS. NAIL PROPERTIES SCHEDULE DESIGNATION LENGTH WIRE DIAMETER HEAD DIAMETER 6d 2"0.113"0.266" 8d 2 1/2"0.131"0.281" 10d 3"0.148"0.312" 12d 3 1/4"0.148"0.312" 16d 3 1/2"0.162"0.344" 20d 4"0.192"0.406" NOTE: 10d COMMON SHORT (2 1/8" LONG) MAY BE USED AT 1/2" AND THINNER PLYWOOD IN LIEU OF 10d COMMON (3") OR 8d COMMON (2 1/2" LONG). NAILING SHALL NOT BREAK THROUGH OUTER PLY OF PLYWOOD. IF PNEUMATIC GUNS ARE USED, THEY SHALL BE ADJUSTED TO SATISFY THE ABOVE CRITERIA. SPECIAL INSPECTIONS: 1.THE OWNER, OR THE OWNER'S AUTHORIZED AGENT (OTHER THAN THE CONTRACTOR AS APPLICABLE) SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS, INCLUDING AS APPLICABLE AN INSPECTOR OF RECORD (IOR), WHO SHALL PROVIDE SPECIAL INSPECTIONS DURING CONSTRUCTION FOR CERTAIN TYPES OF WORK WHEN SO SPECIFIED IN THE CONTRACT DOCUMENTS AND PROJECT SPECIFICATIONS. WHERE AN IOR IS REQUIRED BY THE GOVERNING AGENCY, THE IOR MAY PERFORM SPECIAL INSPECTIONS IF THAT PERSON IS QUALIFIED PER THE GOVERNING AGENCY'S STANDARDS FOR THE SPECIAL INSPECTION REQUIRED. WHERE AN IOR IS NOT REQUIRED, THESE SPECIAL INSPECTIONS SHALL BE IN ADDITION TO AND COMPLEMENTARY WITH THE INSPECTIONS PROVIDED BY THE GOVERNING AGENCY. 2.THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON FROM AN APPROVED AGENCY CONFORMING TO ASTM C1077 WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE ARCHITECT, STRUCTURAL ENGINEER OF RECORD AND THE GOVERNING AGENCY, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. 3.THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH THE DESIGN DRAWINGS, SPECIFICATIONS AND APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE AND OTHER APPLICABLE REGULATIONS IDENTIFIED WITHIN THE CONSTRUCTION DOCUMENTS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE GENERAL CONTRACTOR FOR CORRECTION AND THEN, IF UNCORRECTED, TO THE ATTENTION OF THE ARCHITECT, STRUCTURAL ENGINEER OF RECORD AND THE GOVERNING AGENCY. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE SPECIAL INSPECTOR AND SCHEDULE THE SPECIAL INSPECTIONS WITH ADEQUATE TIME TO ADDRESS ANY AND ALL POTENTIAL DISCREPANCIES PRIOR TO PROCEEDING WITH SUBSEQUENT WORK THAT COVERS OR OTHERWISE MAKES INACCESSIBLE ANY WORK IDENTIFIED AS DEVIATING FROM THE PROJECT REQUIREMENTS. 4.THE SPECIAL INSPECTOR SHALL FURNISH REGULAR INSPECTION REPORTS TO THE ARCHITECT, STRUCTURAL ENGINEER OF RECORD AND THE GOVERNING AGENCY IDENTIFYING THE WORK INSPECTED AND ANY UNCORRECTED DISCREPANCIES FROM THE CONSTRUCTION DOCUMENTS. AT THE CONCLUSION OF THE PROJECT OR THE SPECIAL INSPECTORS ASSIGNED SCOPE OF WORK, THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF HIS OR HER KNOWLEDGE, COMPLETED IN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS (INCLUDING APPROVED RFI'S, ADDENDUMS, ETC.) AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE AND OTHER APPLICABLE REGULATIONS IDENTIFIED WITHIN THE CONSTRUCTION DOCUMENTS. 5.UNLESS NOTED OTHERWISE, SPECIAL INSPECTIONS INDICATED BELOW SHALL BE PROVIDED IN EITHER A CONTINUOUS OR PERIODIC CAPACITY, AS DEFINED BELOW, AS REQUIRED BY THE INDIVIDUAL CODE OR REFERENCED STANDARD. 6.CONTINUOUS - SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS PRESENT WHEN AND WHERE THE WORK TO BE INSPECTED IS BEING PERFORMED. 7.PERIODIC - SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. FOR STRUCTURAL STEEL, PERIODIC INSPECTION IS FURTHER DEFINED SUCH THAT ITEMS ARE OBSERVED ON A RANDOM BASIS. 8.FOR STRUCTURAL STEEL WELDING AND BOLTING, SPECIAL INSPECTION SHALL BE PROVIDED IN EITHER AN OBSERVE OR PERFORM CAPACITY AS DEFINED BELOW: ·OBSERVE (O) - INSPECTOR SHALL OBSERVE THESE ITEMS ON A RANDOM BASIS ·PERFORM (P) - INSPECTOR SHALL OBSERVE OR PERFORM SPECIFIED TASK FOR EACH WELDED OR BOLTED JOINT OR MEMBER 9.QUALITY CONTROL (QC) INSPECTION TASKS SHALL BE PERFORMED BY THE FABRICATOR'S OR ERECTOR'S QC INSPECTOR (QCI) AS INDICATED. QUALITY ASSURANCE (QA) INSPECTION TASKS SHALL BE PERFORMED BY THE QA INSPECTOR (QAI) AS INDICATED. WHEN A TASK IS INDICATED TO BE PERFORMED BY BOTH THE QAI AND QCI, COORDINATION IS PERMITTED SO THAT THE INSPECTION FUNCTIONS ARE PERFORMED BY ONLY ONE PARTY. WHEN THE QAI RELIES ON THE QCI, THE APPROVAL OF THE SEOR AND AGENCY HAVING JURISDICTION IS REQUIRED. 10.THE FOLLOWING CONSTRUCTION ELEMENTS AND MATERIALS SHALL BE INSPECTED AND EVALUATED BY A SPECIAL INSPECTOR IN ACCORDANCE WITH THE NOTED CBC SECTIONS AND REFERENCED STANDARDS, WHERE ELEMENTS AND MATERIALS ARE PRESENT ON THE PROJECT. SEE GENERAL NOTES FOR EACH MATERIAL FOR ADDITIONAL REQUIREMENTS, IN ADDITION TO TABLES AND NOTES BELOW: FRAMED LUMBER SPECIAL INSPECTION NOTES: 1.MOISTURE CONTENT OF 2X FRAMING SHALL BE TESTED WITH A MOISTURE METER HAVING ONE INCH (1”) NEEDLE IN THE PRESENCE OF A SPECIAL INSPECTOR. STRUCTURAL AND MISCELLANEOUS STEEL: 1.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS (AISC 360). 2.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL CONFORM TO THE FOLLOWING SPECIFICATION (UNLESS NOTED OTHERWISE): A.ANGLES AND PLATES ASTM A-36 FY=36KSI 3.AFTER FABRICATION, ALL STEEL SHALL BE CLEANED FREE OF RUST, LOOSE MILL SCALE, AND OIL. 4.ALL STEEL EXPOSED TO MOISTURE OR WEATHER SHALL BE HOT-DIPPED GALVANIZED, UNLESS NOTED OTHERWISE. GALVANIZING SHALL BE IN CONFORMANCE WITH ASTM A123 AND A153. REPAIR GALVANIZING AFTER WELDING SHALL BE IN ACCORDANCE WITH ASTM A780. 5.WHERE CARBON STEEL IS IN CONTACT WITH STAINLESS STEEL OR WHERE EITHER CARBON OR STAINLESS STEEL IS IN CONTACT WITH ALUMINUM, PHENOLIC SHIM OR BREAK SHALL BE INSTALLED TO SEPARATE DISSIMILAR METALS. No.3503 L I GNE L S NO B A LAE A L I OFRNIA N E ER I E ET ORPD F E R IR L.KC E TS AT CFO RE G S I S URALTSRUCT (E ) 5 1 / 8 x 2 4 G L B (E ) 5 1 / 8 x 2 4 G L B (E ) 5 1 / 8 x 2 4 G L B (E ) 5 1 / 8 x 2 4 G L B (E ) 5 1 / 8 x 2 7 G L B , T Y P (E ) 5 1 / 8 x 2 7 G L B , T Y P (E ) 5 1 / 8 x 2 7 G L B , T Y P (E ) 5 1 / 8 x 2 7 G L B , T Y P (E) 6 3/4x43 1/2 GLB, TYP (E) 6 3/4x30 GLB, TYP (E) 6 3/4x36 GLB, TYP (E) 6 3/4x43 1/2 GLB, TYP (E) 6 3/4x30 GLB, TYP (E) 6 3/4x36 GLB, TYP (E) 4x12 @ 8"OC, TYP(E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP (E) 2x @ 24"OC. TYP (E) 1/2" PLYWOOD ROOF SHEATHING, VIF RTU 8 MAX OP WT=586# RTU 2 MAX OP WT=455# RTU 13 MAX OP WT=586# 1 S2.00TYP (E) DUCT OPENING, TYP SCALE:S2.00 ROOF INFILL AT EXISTING OPENING (WHERE OCCURS)2 1 1/2" = 1'-0" (E) SIMPSON HANGER, TYP VIF (E) OPENING (9'-6" MAX) (E ) O P E N I N G (4 ' - 6 " M A X ) NOTE: PROVIDE 10d NAILS @ 6"OC AT ALL (N) PLY EDGES & @ 12"OC EN (E) 2x JOIST PER PLAN, TYP (E) JOIST PER PLAN (E) ROOF SHEATHING PER PLAN (E) SHEATHING (N) SHEATHING EN ROOF SHEATHING PER PLAN SECTION A-A A A 2x PER PLAN 2x BLKG PER PLAN 2x6 @ 24"OC MAX SIMPSON LU26 FACE HANGER EA END, TYP 2x6 BLKG W/ (4)-10d NAILS TO (E) JOIST, TYP (E) (2)-2x 1/2" STRUC PLY SHTG 2x6 BLKG W/ 10d NAILS @ 6"OC, TYP SCALE:S2.00 AC UNIT ANCHORAGE 1 1/2" = 1'-0" PLAN VIEW AT BASE L2 M I N W2 MIN L3x3x3/16 x0'-4" LONG W/ (3)-#12 SMS TO UNIT & 1/2"Ø LAG SCREW (3" MIN PEN) TO 4x BELOW, TYP EA CORNER AS SHOWN (4 TOTAL) 6" MA X TY P 12 " MA X H M A X W1±L1± (E) PLYWOOD ROOF SHEATHING PER PLAN (E) 2x JOIST PER PLAN, TYP SIMP A35, SLEEPER TO SLEEPER, EA CORNER (E) 4x MEMBER WHERE OCCURS PER PLAN 4x SLEEPER (FIELD VERIFY DEPTH), TYP ALL 4 SIDES 1/2" PLYWOOD W/ 10d @ 6",6",12 (BN,EN,FN) ANCHOR PER PLAN VIEW, TYP A A AC UNIT PER PLAN, MAX OP WT=SEE SCHED SIMP A34, TYP EA SIDE, EA END 2 3/4" MIN 8" MAX TYP 2" TYP 4x6 BLKG W/ SIMP A35 EA SIDE, EA END, TYP AT SLEEPER ANGLES 4x6 W/ SIMP A34 EA SIDE, EA END, TYP AT ANGLES AS SHOWN 2x6 @ 16"OC W/ SIMP A34 EA SIDE, EA END, TYP UNO L3x3x12GA x0'-6" BENT PL W/ (2)-1/2"Ø LAG SCREWS (3" MIN PEN) TO SLEEPER & (2)-1/2"Ø LAG SCREWS (4" MIN PEN) TO 4x BLOCK, TYP EA END OF SLEEPER AS SHOWN SECTION A-A 8'-0" MAX TYP EQ TYP EQ TYP EQ TYPEQ TYP NEOPRENE PAD PER MECH, TYP UNDER EA ANCHOR (E) GLB WHERE OCCURS PER PLAN EQUIPMENT SCHEDULE UNIT MAX OP WT H W1 L1 W2 L2 AC-2 455#49"44"48"47"36" AC-8, 13 586#34"46"74"49"62" SCALE:S2.00 ROOF INFILL AT EXISTING OPENING (WHERE OCCURS)2 1 1/2" = 1'-0" (E) SIMPSON HANGER, TYP VIF (E) OPENING (9'-6" MAX) (E ) O P E N I N G (4 ' - 6 " M A X ) NOTE: PROVIDE 10d NAILS @ 6"OC AT ALL (N) PLY EDGES & @ 12"OC EN (E) 2x JOIST PER PLAN, TYP (E) JOIST PER PLAN (E) ROOF SHEATHING PER PLAN (E) SHEATHING (N) SHEATHING EN ROOF SHEATHING PER PLAN SECTION A-A A A 2x PER PLAN 2x BLKG PER PLAN 2x6 @ 24"OC MAX SIMPSON LU26 FACE HANGER EA END, TYP 2x6 BLKG W/ (4)-10d NAILS TO (E) JOIST, TYP (E) (2)-2x 1/2" STRUC PLY SHTG 2x6 BLKG W/ 10d NAILS @ 6"OC, TYP SCALE:S2.00 AC UNIT ANCHORAGE 1 1/2" = 1'-0" PLAN VIEW AT BASE L2 M I N W2 MIN L3x3x3/16 x0'-4" LONG W/ (3)-#12 SMS TO UNIT & 1/2"Ø LAG SCREW (3" MIN PEN) TO 4x BELOW, TYP EA CORNER AS SHOWN (4 TOTAL) 6" MA X TY P 12 " MA X H M A X W1±L1± (E) PLYWOOD ROOF SHEATHING PER PLAN (E) 2x JOIST PER PLAN, TYP SIMP A35, SLEEPER TO SLEEPER, EA CORNER (E) 4x MEMBER WHERE OCCURS PER PLAN 4x SLEEPER (FIELD VERIFY DEPTH), TYP ALL 4 SIDES 1/2" PLYWOOD W/ 10d @ 6",6",12 (BN,EN,FN) ANCHOR PER PLAN VIEW, TYP A A AC UNIT PER PLAN, MAX OP WT=SEE SCHED SIMP A34, TYP EA SIDE, EA END 2 3/4" MIN 8" MAX TYP 2" TYP 4x6 BLKG W/ SIMP A35 EA SIDE, EA END, TYP AT SLEEPER ANGLES 4x6 W/ SIMP A34 EA SIDE, EA END, TYP AT ANGLES AS SHOWN 2x6 @ 16"OC W/ SIMP A34 EA SIDE, EA END, TYP UNO L3x3x12GA x0'-6" BENT PL W/ (2)-1/2"Ø LAG SCREWS (3" MIN PEN) TO SLEEPER & (2)-1/2"Ø LAG SCREWS (4" MIN PEN) TO 4x BLOCK, TYP EA END OF SLEEPER AS SHOWN SECTION A-A 8'-0" MAX TYP EQ TYP EQ TYP EQ TYPEQ TYP NEOPRENE PAD PER MECH, TYP UNDER EA ANCHOR (E) GLB WHERE OCCURS PER PLAN EQUIPMENT SCHEDULE UNIT MAX OP WT H W1 L1 W2 L2 AC-2 455#49"44"48"47"36" AC-8, 13 586#34"46"74"49"62" 3 4 5 6 7 48 ' - 0 " ± V I F 42 ' - 0 " ± V I F 42 ' - 0 " ± V I F 45 ' - 0 " ± V I F A B C 60'-0"± VIF 60'-0"± VIF ST R U C T U R A L E N G I N E E R PR O J E C T I N F O R M A T I O N AC Unit Replacement 1951 Carnegie Ave Santa Ana, CA, 92705 24-0417-00 SH E E T N U M B E R SH E E T T I T L E SH E E T I N F O JOB NUMBER: DRAWN: DESIGNED: CHECKED: ST A M P AP P R O V A L RR GD RLB SU B M I T T A L S A N D R E V I S I O N S ISSUE DATE: NO DATEDESCRIPTION SCALE: H: \ 2 0 2 4 \ 2 4 0 4 1 7 \ 3 _ D r a w i n g s \ D w g s - 0 0 \ 2 4 - 0 4 1 7 - 0 0 _ S 2 . 0 P A R T I A L R O O F F R A M I N G P L A N , S E C T I O N S , A N D D E T A I L S . d w g P L O T T E D B Y : Ru b e n R u i z O N : Oc t o b e r 1 8 , 2 0 2 4 10-30-2024 S2.00 PARTIAL ROOF FRAMING PLAN, SECTIONS, AND DETAILS AS NOTED LONG BEACH • SAN DIEGO LONG BEACH OFFICE 3900 Cover Street, Long Beach CA 90808 • 562.985.3200 S T R U C T U R A L E N G I N SREE No.3503 L I GNE L S NO B A LAE A L I OFRNIA N E ER I E ET ORPD F E R IR L.KC E TS AT CFO RE G S I S URALTSRUCTPRO G R E S S - NO T F O R P L A N REV I E W SCALE:S2.00 PARTIAL ROOF FRAMING PLAN A 1/8" = 1'-0" 1.SEE GENERAL NOTES SHEET(S) FOR APPLICABLE NOTES & ABBREVIATIONS. SEE PROJECT SPECIFICATIONS WHERE APPLICABLE FOR ADDITIONAL INFORMATION. 2.EXISTING CONSTRUCTION IS SHOWN FADED AND IS LABELED AS EXISTING OR (E). NEW CONSTRUCTION IS SHOWN DARK AND IS SPECIFICALLY REFERENCED BY DETAILS AND NOTES. 3.EXISTING CONDITIONS ARE SHOWN TO THE BEST OF OUR KNOWLEDGE. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ACTUAL CONDITIONS. DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THOSE SHOWN ON THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING. 4.DIMENSIONS OF EQUIPMENT ANCHOR/ MOUNTING LOCATIONS SHOWN ON PLANS AND/OR DETAILS ARE TO BE COORDINATED WITH ACTUAL EQUIPMENT TO BE INSTALLED. 5.CONTRACTOR TO VERIFY THE EXACT SIZE AND LOCATION OF ALL EQUIPMENT ANCHOR/ MOUNTING HOLES PRIOR TO INSTALLATION. WHERE ACTUAL EQUIPMENT DIMENSIONS DO NOT FALL WITHIN THE MINIMUM OR MAXIMUM DIMENSIONS PROVIDED ON PLANS AND/OR DETAILS, NOTIFY SEOR AND AWAIT DIRECTION PRIOR TO PROCEEDING WITH WORK. 6.DO NOT CUT ANY NEW OPENINGS OR ENLARGE ANY EXISTING OPENINGS IN THE ROOF OR WALLS (FOR DUCTS, PIPES, ETC.) UNLESS SPECIFICALLY SHOWN ON THESE STRUCTURAL DRAWINGS. 7.MAXIMUM OPERATING WEIGHTS NOTED ON THE PLANS INCLUDE THE WEIGHT OF UNIT PLUS ALL ACCESSORIES, CURBS, ISOLATORS, ETC. THAT ARE ASSOCIATED WITH THE UNIT. FRAMING PLAN NOTES No.3503 L I GNE L S NO B A LAE A L I OFRNIA N E ER I E ET ORPD F E R IR L.KC E TS AT CFO RE G S I S URALTSRUCT ORANGE COUNTY FIRE AUTHORITY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL proj and RESIDENTIAL TRACT developments CITY OF SANTA ANA P11 nnina and Buildi Agency swrc F R PERMIT ISSU NCE INSTRUCTIONS: • Fill in the project/business address and provide a brief description of the scope of work and type of business N rftt: will take place. • Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification sec iggMe- • If you answer; - "YES" to any part of questions 1 through 10, submit the type of plan Indicated in Italics to O FX . • In some cases, other plan types not indicated herein may also be necessary depending on specific condition, - or operations, • Visit www.ocfa.ora for submittal information and locations. If you .need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine., CA 92602. Address. % I e Project 5copel8 si essDescription rt RL 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) . 2. Property is adjacent to a wildland area or non -irrigated native vegetation? Fire Master Plan (PR145); aFuel Modification Platt may also be required. (PR120, PR124) 3. �(� Located in or < 100' from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300' from ` 1 an oil/gas seep, or < 1000' from a landfill? Methane Work Plan. (PR170) 4. Installation/modificationlrepair of underground piping, backflow preventers, or fire department connections serving private fire hydra nt/sprinklerlstandpipe systems? Underground Plan. (PR470, PR475) 5. ( Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sci t. (> 1,000 sq.ft. for trainingladulteducation) or > 49 people? Healthcareloutpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring forages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. (� Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, andlor Alarm Plan depending on the occupancy and o pe of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion);. welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special FgiiipmentPlatt (PR31S, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if Hoccupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 600 sq. ft. where items are located higher than 12' (6' for high -hazard `•� �"++•i/commodities, plastic, rubber, foam, etc.)? High piled Storage Plan (PR330) 10.(J j t� Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a ``�� "`•••��� commercial cooking hood? Hood & Duct Extinguishing System, notjust the hood mechanical plan, (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system Is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification Is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone; Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may, be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— initw, the building department will determine specific requirements. I certifv under penalty of neriury under the laws of the State of California that the 40ve is Erne; , Print Name (' ' Myta l Signature ` Phone Number Date Building Department: f you have verified that all of the questions have been answered accurately as 'NO", and the project does not otherwise require OCF.4 review of sprinkler or alarm plans*, then your tray accept this signed form as a written release that OCFA review is not required, Should you still require that the applicant have plans approved by OCFA, please initial here_or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE CITY OF SANTA ANA Planning and Building Agency E`c ORANGE COUNTY FIRE AUTHORITY Plan Referral Form i rrog�e Required the answers on the Plan Submittal Criteria FortBuilding Department m ( nthehe �revers) areal "No". when Approved FOR PERMIT ISSUANCE Master ID: City / County Official Requesting Review: k An U 114 _T 1 J l t I t City / County Reference #: Date: J, 1 City / County: � -. (J n6 41(k, or—, _ E-Mail: -e Contact Name: �� ��h 17et Phone #: "i� b4D " co -Al l` Title: l Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form, ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/Cou mujgs C:r� 1r� OCFA COMMENTS: ❑ No further action required on this specific plan type, based on information provided on: ❑ Project to be taken in for OCFA Review. Other: Name: Contact #: Date: OCFA Authorization